WorldWideScience

Sample records for small suction cups

  1. Dielectric elastomer actuators for octopus inspired suction cups.

    Science.gov (United States)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  2. Dielectric elastomer actuators for octopus inspired suction cups

    International Nuclear Information System (INIS)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-01-01

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms. (paper)

  3. Octopus-like suction cups: from natural to artificial solutions.

    Science.gov (United States)

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  4. Rekonstruksi pada Perforasi Palatum Akibat Pneggunaan Gigi Tiruan Lengkap Rahang Atas dengan Suction Cup

    Directory of Open Access Journals (Sweden)

    Cristiani Nadya Pramasari

    2012-12-01

    Full Text Available Latar belakang. Pemasangan suction cup pada gigi tiruan lengkap rahang atas merupakan salah satu cara untuk meningkatkan referensi. Kondisi vakum oleh karena suction cup ini dalam waktu jangka panjang dan tidak terkontrol mengakibatkan nekrosis jaringan yaitu adanya perforasi palatum. Tujuan. Melaporkan rekonstruksi penutupan perforasi palatum sebagai komplikasi penggunaan gigi tiruan lengkap rahang atas dengan suction cup. Laporan Kasus. Pada tanggal 11 September 2012 seorang pria berusia 64 tahun datang ke Poliklinik Bedah Mulut RSUP dr. Sardjito Yogyakarta dengan keluhan terdapat lubang pada langit-langit. Pasien menggunakan gigi palsu buatan tukang gigi dengan perekat berbahan karet pada langit-langit selama 5 tahun. Selama penggunaan gigi palsu pasien sering mengalami sakit dan pembengkakan di langit-langit sampai keluar nanah dan akhirnya terbentuk lubang sehingga jika minum air keluar dari hidung. Pemeriksaan rontgen oklusal rahang atas tampak adanya resorbsi regio palatum durum. Rekonstruksi menggunakan teknik push back modifikasi dilakukan untuk penutupan perforasi palatum di bawah anestesi umum. Kesimpulan. Suction cup pada gigi tiruan lengkap rahang atas mengakibatkan kerusakan jaringan lunak dan jaringan keras rongga mulut. Perforasi palatum yang diakibatkan oleh suction cup ini dapat dilakukan rekonstruksi dengan teknik push back dengan hasil yang cukup optimal.   Background. Suction cups are used to get retention of the complete dentures. The uncontrolled constant vacuum created by the suction cup induces necrosis of tissues and perforation ofpalate. Objective. To report reconstruction for palatal perforation closure as a complication due to prolonged use of maxillary denture with suction cup. Case Report. A 64 years old male patient came to the Department of Oral Surgery, Sardjito General Hospital Yogyakarta on September 11, 2012 with the complaint of hole in his palate. He was wearing dentures for the past 5 years. He also

  5. In situ sampling of small volumes of soil solution using modified micro-suction cups

    NARCIS (Netherlands)

    Shen, Jianbo; Hoffland, E.

    2007-01-01

    Two modified designs of micro-pore-water samplers were tested for their capacity to collect unbiased soil solution samples containing zinc and citrate. The samplers had either ceramic or polyethersulfone (PES) suction cups. Laboratory tests of the micro-samplers were conducted using (a) standard

  6. Device for the prehension by means of suction cups

    International Nuclear Information System (INIS)

    Gabillet, Maurice

    1980-01-01

    The difficulties encountered while utilising suction-cups, are mainly caused by the skirts. The skirts are more or less adaptable to the surface of the objects to be handled. The skirt of the device presented, is made out of a round supple elastic bag containing solid particles. By creating a vacuum in the bag, the particles become a solid entity. The bag filled with the particles becomes rigid and can take exactly the shape of the object to be lifted. By creating a second vacuum in the axis of the bag, the object can be lifted. Several suction-cups can be used simultaneously

  7. Bio-inspired Miniature Suction Cups Actuated by Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Hu Bing-shan

    2010-02-01

    Full Text Available Wall climbing robots using negative pressure suction always employ air pumps which have great noise and large volume. Two prototypes of bio-inspired miniature suction cup actuated by shape memory alloy (SMA are designed based on studying characteristics of biologic suction apparatuses, and the suction cups in this paper can be used as adhesion mechanisms for miniature wall climbing robots without air pumps. The first prototype with a two-way shape memory effect (TWSME extension TiNi spring imitates the piston structure of the stalked sucker; the second one actuated by a one way SMA actuator with a bias has a basic structure of stiff margin, guiding element, leader and elastic element. Analytical model of the second prototype is founded considering the constitutive model of the SMA actuator, the deflection of the thin elastic plate under compound load and the thermo-dynamic model of the sealed air cavity. Experiments are done to test their suction characteristics, and the analytical model of the second prototype is simulated on Matlab/simulink platform and validated by experiments.

  8. Bio-inspired Miniature Suction Cups Actuated by Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Hu Bing-Shan

    2009-09-01

    Full Text Available Wall climbing robots using negative pressure suction always employ air pumps which have great noise and large volume. Two prototypes of bio-inspired miniature suction cup actuated by shape memory alloy (SMA are designed based on studying characteristics of biologic suction apparatuses, and the suction cups in this paper can be used as adhesion mechanisms for miniature wall climbing robots without air pumps. The first prototype with a two-way shape memory effect (TWSME extension TiNi spring imitates the piston structure of the stalked sucker; the second one actuated by a one way SMA actuator with a bias has a basic structure of stiff margin, guiding element, leader and elastic element. Analytical model of the second prototype is founded considering the constitutive model of the SMA actuator, the deflection of the thin elastic plate under compound load and the thermo-dynamic model of the sealed air cavity. Experiments are done to test their suction characteristics, and the analytical model of the second prototype is simulated on Matlab/simulink platform and validated by experiments.

  9. Preliminary study of efficacy of cup suction in the correction of typical pectus excavatum.

    Science.gov (United States)

    Lopez, Manuel; Patoir, Arnaud; Costes, Frederic; Varlet, François; Barthelemy, Jean-Claude; Tiffet, Olivier

    2016-01-01

    This preliminary qualitative study evaluates the efficacy of cup suction in the correction of pectus excavatum (PE), and examines the place of this system as a strategic treatment and as an alternative to surgery. Between October 2011 and June 2014, a total of 84 patients (children and adult) presenting with PE were treated by cup suction, in our chest wall deformities unit. On first consultation, the patients with typical PE and with at least partial correction during the first application of cup suction and a maximal suction pressure for correction of less than 300 mbar (millibars) were included in this study. 11 patients were excluded from the present study as they presented with a complex carinatum/excavatum. The remaining 73 patients were divided into two groups: Group I, adult patients ≥ 18 year old, 17 patients. The mean age was 22.8 years old. Group II, pediatric patients cup suction, strengthening exercises, and clinical follow-up every two to three months. The evaluation criteria during, and on the completion of the trial were: depth of the PE, morbidity and treatment compliance. Partial and final results were evaluated by the patients, their parents, and doctor, using a qualitative scoring scale. A total of 73 patients presenting typical PE (symmetric in 52 cases and asymmetric in 21 cases) were treated by cup suction. The mean depth of PE was 23 mm (9-44). Of the 73 patients, one adult abandoned treatment and three children abandoned follow-up. The mean time of use of the device was 4h daily. At six months of treatment, the mean depth of PE was 9 mm (0-30) across all patients. 23 patients completed the treatment and exhibited flattening of the sternum. These patients were considered to have an excellent aesthetic result. The mean treatment duration to normal reshape was achieved at 10 months (4-21). The remaining patients are improving under continuing active treatment. The mean depth of PE in this group was 12 mm (4-30), after a mean treatment

  10. Fluid Model of Sliding Suction Cup of Wall-climbing Robots

    Directory of Open Access Journals (Sweden)

    Fu Zhuang

    2008-11-01

    Full Text Available The adhering capability, one of the most important performance indexes of wall-climbing robots(WCRs, should be taken into account when a WCR is designed. This paper proposes a novel approach for investigating the adhering characteristics of the sliding suction cup (SSCs using fluid network theory to enhance the adhering capability of WCRs. The fluid models of the SSCs of two WCRs are developed and equivalent circuits in three cases are presented. The dynamic responses of negative pressure in SSCs are obtained and validated by a set of experiments. It indicated that the theoretical analysis is reasonable and can give some valuable design criteria on the structure parameters of SSCs and control strategies of suction force of SSCs.

  11. [Comparison of the effects of the intervention with electric thermal bian stone and air suction cup on blood perfusion at meridian points].

    Science.gov (United States)

    Zhao, Pengna; Wang, Yanping; Gu, Feifei; Li, Chaozheng; Wei, Yulong; Wang, Guangjun; Zhang, Weibo

    2018-02-12

    To observe the impacts of the intervention with electric thermal bian stone and air suction cup on blood perfusion (BP) at meridian points and explore the approach of accurate measurement and regulation of meridian qi and blood balance in "precise acupuncture". The laser Doppler line scanner (LDLS) was used to measure BP at bilateral yua n-primary points at the pericardium meridian, the triple energizer meridian, the gallbladder meridian and the liver meridian (small cycle of jueyin to shaoyang meridians) at 31 healthy receptors. The bias ratio of blood perfusion (BPBR) deviated to the reference value was calculated. The electric thermal bian stone and air suction cup were used in the intervention at the he -sea points of the affected meridians in which BPBR was relatively higher at the yuan -primary points. The electric thermal bian stone therapy was used when BPBR was less than -30% and the air suction cupping therapy was used when BPBR was higher than 30%. BP was measured twice before intervention and it was measured separately at the moment after intervention and in 20 min after intervention. The means of BP before and after intervention and the change ratio of blood perfusion (BPCR) before intervention, at the moment after intervention and 20 min after intervention were calculated. 1. After the intervention of electric thermal bian stone, BP mean was increased from (103.51±41.21) PU to (121.97±56.22) PU ( P 0.05), but the change ratio was highly remained. 2. After intervention with air suction cup, BP mean was reduced from (194.83±81.14) PU to (173.88±88.26) PU. Before intervention, at the moment after intervention and 20 min after intervention, separately, BPCR were (7.62±30.49)%, (-12.12±18.20)% and (-14.35±21.25)%. BPCR at the moment after intervention and in 20 min after intervention were significantly different from that before intervention (both P cup is opposite.

  12. A wet-tolerant adhesive patch inspired by protuberances in suction cups of octopi

    Science.gov (United States)

    Baik, Sangyul; Kim, Da Wan; Park, Youngjin; Lee, Tae-Jin; Ho Bhang, Suk; Pang, Changhyun

    2017-06-01

    Adhesion strategies that rely on mechanical interlocking or molecular attractions between surfaces can suffer when coming into contact with liquids. Thus far, artificial wet and dry adhesives have included hierarchical mushroom-shaped or porous structures that allow suction or capillarity, supramolecular structures comprising nanoparticles, and chemistry-based attractants that use various protein polyelectrolytes. However, it is challenging to develop adhesives that are simple to make and also perform well—and repeatedly—under both wet and dry conditions, while avoiding non-chemical contamination on the adhered surfaces. Here we present an artificial, biologically inspired, reversible wet/dry adhesion system that is based on the dome-like protuberances found in the suction cups of octopi. To mimic the architecture of these protuberances, we use a simple, solution-based, air-trap technique that involves fabricating a patterned structure as a polymeric master, and using it to produce a reversed architecture, without any sophisticated chemical syntheses or surface modifications. The micrometre-scale domes in our artificial adhesive enhance the suction stress. This octopus-inspired system exhibits strong, reversible, highly repeatable adhesion to silicon wafers, glass, and rough skin surfaces under various conditions (dry, moist, under water and under oil). To demonstrate a potential application, we also used our adhesive to transport a large silicon wafer in air and under water without any resulting surface contamination.

  13. Seasonal dynamics of nitrate and ammonium ion concentrations in soil solutions collected using MacroRhizon suction cups.

    Science.gov (United States)

    Kabala, Cezary; Karczewska, Anna; Gałka, Bernard; Cuske, Mateusz; Sowiński, Józef

    2017-07-01

    The aims of the study were to analyse the concentration of nitrate and ammonium ions in soil solutions obtained using MacroRhizon miniaturized composite suction cups under field conditions and to determine potential nitrogen leaching from soil fertilized with three types of fertilizers (standard urea, slow-release urea, and ammonium nitrate) at the doses of 90 and 180 kg ha -1 , applied once or divided into two rates. During a 3-year growing experiment with sugar sorghum, the concentration of nitrate and ammonium ions in soil solutions was the highest with standard urea fertilization and the lowest in variants fertilized with slow-release urea for most of the months of the growing season. Higher concentrations of both nitrogen forms were noted at the fertilizer dose of 180 kg ha -1 . One-time fertilization, at both doses, resulted in higher nitrate concentrations in June and July, while dividing the dose into two rates resulted in higher nitrate concentrations between August and November. The highest potential for nitrate leaching during the growing season was in July. The tests confirmed that the miniaturized suction cups MacroRhizon are highly useful for routine monitoring the concentration of nitrate and ammonium ions in soil solutions under field conditions.

  14. Developing and validating a sham cupping device.

    Science.gov (United States)

    Lee, Myeong Soo; Kim, Jong-In; Kong, Jae Cheol; Lee, Dong-Hyo; Shin, Byung-Cheul

    2010-12-01

    The aims of this study were to develop a sham cupping device and to validate its use as a placebo control for healthy volunteers. A sham cupping device was developed by establishing a small hole to reduce the negative pressure after suction such that inner pressure could not be maintained in the cup. We enrolled 34 healthy participants to evaluate the validity of the sham cupping device as a placebo control. The participants were informed that they would receive either real or sham cupping and were asked which treatment they thought they had received. Other sensations and adverse events related to cupping therapy were investigated. 17 patients received real cupping therapy and 17 received sham cupping. The two groups felt similar sensations. There was a tendency for subjects to feel that real cupping created a stronger sensation than sham cupping (48.9±21.4 vs 33.3±20.3 on a 100mm visual analogue scale). There were only mild to moderate adverse events observed in both groups. We developed a new sham cupping device that seems to provide a credible control for real cupping therapy by producing little or no negative pressure. This conclusion was supported by a pilot study, but more rigorous research is warranted regarding the use of this device.

  15. Cupping therapy: An analysis of the effects of suction on skin and the possible influence on human health.

    Science.gov (United States)

    Lowe, Duane T

    2017-11-01

    Cupping therapy is a traditional therapy that has been employed worldwide for thousands of years. Despite a lack of quality clinical studies evaluating the efficacy of cupping therapy, its long history and widespread use throughout the world suggests the commonly claimed health benefits should not be completely discounted as without merit. The goal of this paper is to present the research detailing what is known concerning the effects of suction on skin and underlying tissue, and the reaction of the body to that stimulus. Understanding the literature on the physiological effects of this mechanical force may help elaborate an explanation for the advertised local and systemic effects of cupping therapy. Negative pressure causes stretching of the skin and underlying tissue and dilation of the capillaries. This stimulates an increase in tissue blood flow, eventually leading to capillary rupture and ecchymosis. Macrophages phagocytize the erythrocytes in the extravascular space which stimulates the production of Heme Oxygenase-1 (HO-1) to metabolize the heme. Heme catalysis results in the production of carbon monoxide (CO), biliverdin(BV)/bilirubin(BR) and iron. HO-1, BV, BR, and CO has been shown to have antioxidant, anti-inflammatory, antiproliferative, and neuromodulatory effects in animal and human systems. These substances also stimulate a shift of macrophages to the anti-inflammatory M2 phenotype. There is evidence that the effects are both local and systemic. Besides the mechanical effect of cupping increasing the local blood flow and stretching underlying tissue, activation of the HO-1 system could account for many of cupping therapy's claimed local and systemic health benefits. Published by Elsevier Ltd.

  16. 78 FR 20316 - Final Issuance of General NPDES Permits (GP) for Small Suction Dredges in Idaho

    Science.gov (United States)

    2013-04-04

    ... System (NPDES) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction... Small Suction Dredges in Idaho AGENCY: Environmental Protection Agency, Region 10. ACTION: Final notice... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  17. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  18. 77 FR 25717 - Proposed Issuance of a General NPDES Permit for Small Suction Dredging

    Science.gov (United States)

    2012-05-01

    ...) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction dredges (intake nozzle... ENVIRONMENTAL PROTECTION AGENCY [FRL-9666-1] Proposed Issuance of a General NPDES Permit for Small... certifies ``will not, if promulgated, have a significant economic impact on a substantial number of small...

  19. New is the well-forgotten old: The use of dry cupping in musculoskeletal medicine.

    Science.gov (United States)

    Rozenfeld, Evgeni; Kalichman, Leonid

    2016-01-01

    Cupping is an ancient technique used in treating pain and various disorders. Different techniques have been developed over time, however, applying a cup to create suction over a painful area, is common to all. Dry or fire cupping, used on the intact skin, leaves bluish circular hematomas. Recently, interest in cupping has re-emerged and subsequently, several studies have begun to investigate the mechanisms of cupping therapy. Mechanically, cupping increases blood circulation, whereas physiologically it activates the immune system and stimulates the mechanosensitive fibers, thus leading to a reduction in pain. There is initial scientific evidence that dry cupping is able to reduce musculoskeletal pain. Since cupping is an inexpensive, noninvasive and low-risk (if performed by a trained practitioner) therapeutic modality, we believe that it should be included in the arsenal of musculoskeletal medicine. It is essential to perform additional studies clarifying the biological mechanism and clinical effects of cupping. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. [Application of blistering cupping].

    Science.gov (United States)

    Gu, Xingui; Chen, Zelin; Chen, Bo; Fan, Yihua; Chen, Xianghong

    2016-11-12

    Blistering cupping is special as eliminating wind and dampness as well as removing phlegm and blood stasis, and it achieves effects through suction. In this paper we reviewed relevant literature combined with clinical experience so as to summarize its operation attention through exploring the origin, mechanism and application. We divide the progress into the blistering period, the phlegm-stasis-eliminating period, and the escharosis period according to the changes of bubble and the things pulled out. Blistering cupping creates ways to eliminate concrete unhealthy influences through smoothing meridians and collaterals, such as phlegm and retained fluid, dampness and blood stasis. Thus chronic diseases are relieved. Also,we propose the rules of "blistering acupoints being related to disease location as well as the nature of acupoints and diseases". The therapy has been used to treat diseases of respiratory system, osteoarticular, skin and subcutaneous tissue, mental and behavioral disorders, and tumor, among which the effects of intractable diseases of respiratory and osteoarticular systems are definite. It deserves to be further explored and promoted.

  1. Investigation of turbine ventilator performance after added wind cup for room exhaust air applications

    Science.gov (United States)

    Harun, D.; Zulfadhli; Akhyar, H.

    2018-05-01

    The turbine ventilator is a wind turbine with a vertical axis that has a combined function of the wind turbine and a suction fan. In this study, the turbine ventilator modified by adding a wind cup on the top (cap) turbine ventilator. The purpose of this experiment is to investigated the effect of the addition of wind cup on the turbine ventilator. Turbine ventilator used is type v30 and wind cup with diameter 77 mm. The experiment was conducted using a triangular pentagon model space chamber which was cut off to place the ventilator turbine ventilation cup with a volume of 0.983 m3 (equivalent to 1 mm3). The results of this study indicate that at an average wind speed of 1.8 m/s, the rotation of the turbine produced without a wind cup is 60.6 rpm while with the addition of a wind cup in the turbine ventilator is 69 rpm. The average increase of rotation turbine after added win cup is 8.4 rpm and the efficiency improvement of turbine ventilator is 1.7 %.

  2. 75 FR 3731 - Proposed Issuance of a General NPDES Permit for Small Suction Dredging-Permit Number IDG-37-0000

    Science.gov (United States)

    2010-01-22

    ... System (NPDES) general permit to placer mining operations in Idaho for small suction dredges (intake... ENVIRONMENTAL PROTECTION AGENCY [FRL-9104-3] Proposed Issuance of a General NPDES Permit for Small... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  3. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.

    2014-05-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  4. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.; Wang, Shiquan; Gardineer, Bayard; Christensen, David L.; Aukes, Daniel M.; Cutkosky, Mark

    2014-01-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  5. Cup-mixing type cup vending machines; Cup mixing shiki cup jido hanbaiki

    Energy Technology Data Exchange (ETDEWEB)

    Nishiwaki, S.; Nagasaki, T.; Hori, S. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1996-07-10

    This paper introduces the newly developed cup-mixing type cup vending machines. In the vending machines, the powder material for each beverage is stored, and the powder material delivered to a cup is carried to the cooking block by the carrier mechanism and cooked and mixed using a propeller mixer after hot and cold water are put. These vending machines meet the needs to the diversified and quality taste. The ejection port of products was also improved, and the door was designed to be higher in grade. The main block of structure is described next. The cup carrier mechanism consists of X, Y, and Z axes, and a hand. The cup is positioned by the control of a stepping motor. The number of propeller rotations in the propeller mechanism can be set to nine levels. The mixing position can also be set freely. In the temporary material reservation mechanism, the stored material is temporarily reserved until a cup is carried. The ejection port door of a cup is opened or closed automatically. The control block that drives the cup carrier mechanism is connected with the host unit by serial communication. 9 figs., 1 tab.

  6. Tissue holding device for use during surgical procedure, has contact body with suction foot and suction mouth that is surrounded by rim, and suction pipe connected to suction chamber

    OpenAIRE

    Vonck, D.; Goossens, R.H.M.; Flipsen, S.F.J.; Jakimowicz, J.J.; Van der Putten, E.P.W.

    2009-01-01

    The device has a locking ring (5), a connector (6), and a contact body (1) with a suction foot and a suction mouth (8), where the mouth is surrounded by a rim (10), which is substantially located in a plane of the suction foot. A suction chamber (9) has a sieve-shaped inner wall (2) and a transparent side wall, and a suction pipe (11) is connected to the chamber.

  7. Iatrogenic artefacts attributable to traditional cupping therapy in a shotgun fatality.

    Science.gov (United States)

    Cavlak, Mehmet; Özkök, Alper; Sarı, Serhat; Dursun, Ahmet; Akar, Taner; Karapirli, Mustafa; Demirel, Birol

    2015-10-01

    Cupping is a traditional treatment method that has been used for thousands of years to diminish pain, restore appetite and improve digestion, remove tendency to faint or remove 'bad blood' from the body. The suction of the cup is created by fire or mechanical devices. This procedure may result in circular erythema, petechiae, purpura, ecchymosis, burns and may be mistaken for trauma-related ecchymosis or livor mortis. Forty-year-old male was died by shotgun injuries in the same day of the wounding. Circular ecchymoses were observed on the forehead, within the scalp of occipital region, the back of the neck, and on the back. They were defined as ecchymoses in the first examination made by a general practitioner. In the external examination during the legal autopsy superficial incisions were observed on the circular ecchymoses. The shape, localization and color of and the characteristics of incisions on the circular lesions were concluded to be caused by the dry cupping therapy and wet cupping therapy procedures. These lesions and their formation mechanisms should be well-known by the forensic medical examiners and the other medical personnel involved in the forensic medical examination. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  8. Ilaj bil hijamah (cupping therapy) in the Unani system of medicine: anecdotal practice to evidence based therapy.

    Science.gov (United States)

    Abbas Zaidi, S M; Jameel, S S; Jafri, Kehkashan; Khan, Shariq A; Ahmad, Ehsan

    2016-08-01

    Cupping (Hijamah) therapy is very well documented as a result of several thousand years of clinical experiences in Unani medicine. In this procedure, suction is created by various means either with or without bloodletting. Though this therapy is being widely practiced across the globe for treating many chronic and intractable ailments but many reports reveal its unscientific and improper practices which results in many complications. Therefore to develop standard operative procedures and to propose protocols of cupping therapy in various diseases is the need of hour. A thorough literature review of relevant journals and textbooks was performed to gather the maximum available data on cupping therapy. This paper seeks to introduce the general concepts of cupping therapy in Unani medicine and other traditional systems of medicine, shortcomings and limitations of the currently published studies and suggest ways to improve these technical/methodological flaws. In addition, the authors have also attempted to provide the cupping related materials, hypotheses, observations which will provide the researchers the base for evaluating their usefulness in future clinical trials.

  9. Utilization of Cupping Therapy in the Treatment of Vascular Thoracic Outlet Syndrome in a Collegiate Pitcher: A Case Study

    Directory of Open Access Journals (Sweden)

    Stephen A. Cage

    2017-12-01

    Full Text Available Objective: Present a clinical case detailing the effectiveness of dry cupping therapy in treating thoracic outlet syndrome. The utilization of dry cupping therapy on a 20-year-old collegiate baseball pitcher with diagnosed thoracic outlet syndrome is presented. Background: Thoracic outlet syndrome is a relatively rare musculoskeletal condition affecting 1/100,000 patients annually. Dry cupping therapy is an ancient therapeutic modality that utilizes various means of suction with the goal of decompressing myofascial layers. Treatment: Following diagnosis, patient was successfully treated in two weeks using dry cupping therapy. The patient experienced no further incidence of thoracic outlet syndrome symptoms and was able to complete the remainder of his competitive season. Uniqueness: The patient’s thoracic outlet syndrome was diagnosed at an early stage, leading to the need of clearance from a vascular specialist before returning to competition. To the author’s knowledge, there are currently no published case reports detailing the use of cupping therapy to treat thoracic outlet syndrome. Conclusion: Cupping therapy may be a viable treatment option when seeking to address tight musculature. Further research needs to be conducted to determine optimal parameters for cupping therapy as a therapeutic modality.

  10. Prevalence of disc cupping in non-glaucomatous eyes

    Directory of Open Access Journals (Sweden)

    José Pablo Chiappe

    2015-02-01

    Full Text Available This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter 1.5 times (respectively the diameter of the ophthalmoscope's selected light spot on the posterior pole. The cupping was classified as the ratio of the vertical cupping diameter and the vertical disc diameter on a relative decimal scale from 0.0 to 1.0.This study included 184 subjects with a mean age of 40.5 ± 9.5 years; 149 (81% were males. Their mean ocular pressure was 12.4 ± 1.5 mmHg (range 10-17 mmHg. There was a high correlation between optic disc sizes and cupping in the right and left eyes (Pearson Correlation r = 0.866, p < 0.001; therefore, for simplicity only the data for right eyes are presented. According to our definition, the optic discs in these eyes comprised 27 (14.7% small, 141 (76.6% medium and 16 (8.7% large. The small optic discs were rarely cupped, and the large optic discs were always cupped. Optic disc cupping greater than 0.7 was rarely found and should be suspect of glaucoma. Clinical doctors should be aware of this and refer those subjects with abnormal cupping to the specialist.

  11. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    Science.gov (United States)

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle cup-host bone fixation, especially when the cup-CE angle is small, such as cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  12. Comparison of different soil water extraction systems for the prognoses of solute transport at the field scale using numerical simulations, field and lysimeter experiments

    Energy Technology Data Exchange (ETDEWEB)

    Weihermueller, L

    2005-07-01

    To date, the understanding of processes, factors, and interactions that influence the amount of extracted water and the solute composition sampled with suction cups is limited. But this information is required for process description of solute transport in natural soils. Improved system understanding can lead to a low cost and easy to install water sampling system which can help to predict solute transport in natural soils for the benefit of environmental protection. The main objectives of this work were to perform numerical simulations with different boundary conditions and to implement the findings in the interpretation of the lysimeter and field experiments. In a first part of this thesis, theoretical considerations on the processes affecting the spatial influence of a suction cup in soil and changes in solute transport initiated by the suction cups are presented, including testing and validation of available model and experimental approaches. In the second part, a detailed experimental study was conducted to obtain data for the comparison of the different soil water sampling systems. Finally, the numerical experiments of the suction cup influence were used for the interpretation of the experimental data. The main goals are summarized as follows: - Characterization of the suction cup activity domain (SCAD), suction cup extraction domain (SCED) and suction cup sampling area (SCSA) of active suction cups (definitions are given in Chapter 6). - Determination of the boundary conditions and soil properties [e.g. infiltration, applied suction, duration of water extraction, soil hydraulic properties and soil heterogeneity] affecting the activity domain, extraction domain and sampling area of a suction cup. - Identification of processes that change the travel time and travel time variance of solutes extracted by suction cups. - Validation of the numerically derived data with analytical and experimental data from literature. - Comparison of the experimental data obtained

  13. Design and construction of a faraday cup for measuring small electron currents

    International Nuclear Information System (INIS)

    Veyssiere, A.

    1967-01-01

    This paper describes the design of a device for measuring and integrating very small currents generated by the impact of a charged particle beam upon a Faraday cup. Part one considers the detector as such. The main component is a graphite bloc capable of stopping practically all the incident charges. Part two describes the associated electrode apparatus required to measure better than 10 -13 ampere with a precision- of 1 per cent: Integration of such weak currents over periods of several hours, in the presence of a strong background current, is also discussed. (author) [fr

  14. Field measurements of groundwater pollution from agricultural land use

    International Nuclear Information System (INIS)

    Cepuder, P.

    2000-01-01

    This study was carried out in a problem area located to the northeast of Vienna. Several devices were installed for collecting water samples from the soil profile to measure nitrate concentration: suction cups, soil-water samplers, tensiometers and small lysimeters. Measurements of N leaching from four levels of fertilizer application were made at Gross Enzersdorf under irrigated wheat using suction cups and lysimeters. In order to determine fertilizer-N uptake by plants and the amounts retained in the soil and leached, 15 N-enriched fertilizer was applied to micro-plots. The nitrate concentrations below the root zone were measured for winter wheat followed by a cover crop, using suction cups. Soil-water contents were measured in the soil profile with a neutron probe and gypsum blocks, and suctions were measured with tensiometers at four depths. The yields of crops together with total N in grain and straw from fertilizer and soil were calculated. Also presented are data on the mineralization, immobilization and actual fertilizer used by the crops. Winter wheat took up between 27% and 44% of the applied fertilizer. The storage of fertilizer N in soil ranged between 22% and 36%, and only a small fraction was leached. (author)

  15. Robust Color Choice for Small-size League RoboCup Competition

    Directory of Open Access Journals (Sweden)

    Qiang Zhou

    2004-10-01

    Full Text Available In this paper, the problem of choosing a set of most separable colors in a given environment is discussed. The proposed method models the process of generating theoretically computed best colors, printing of these colors through a color printer, and imaging the printed colors through a camera into an integrated framework. Thus, it provides a feasible way to generate practically best separable colors for a given environment with a set of given equipment. A real world application (robust color choice for small-size league RoboCup competition is used as an example to illustrate the proposed method. Experimental results on this example show the competitiveness of the colors learned from our algorithm compared to the colors adopted by other teams which are chosen via an extensive trial and error process using standard color papers.

  16. [Tripolar cups].

    Science.gov (United States)

    Fink, B

    2015-04-01

    Tripolar cups can be separated into constrained and unconstrained dual-mobility cups. The latter show better survival and revision rates. The main problem is the polyethylene wear. Therefore modern types of polyethylene are used in these cups. The indications for dual-mobility cups are recurrent dislocation and situations where the risk of dislocation is increased. Georg Thieme Verlag KG Stuttgart · New York.

  17. Safety of cupping during bevacizumab therapy.

    Science.gov (United States)

    Klempner, Samuel J; Costa, Daniel B; Wu, Peggy A; Ariyabuddhiphongs, Kim D

    2013-08-01

    This study reports on the safety of the complementary and alternative medicine (CAM) practice of cupping in a patient undergoing concomitant therapy with bevacizumab for advanced non-small-cell lung cancer (NSCLC), and raises awareness of the need for improved communication between CAM practitioners and oncologists during the care of patients with cancer. The practice of cupping generates local hyperemia, disrupts superficial vasculature in the dermis, and leads to cutaneous lesions including circular erythema, edema, and subsequently ecchymosis. There are no data on the safety of cupping in patients being treated with bevacizumab. This is a single-institution case report. The setting for this study was a tertiary-care academic medical center. A patient with advanced NSCLC received four cycles of carboplatin AUC 6, paclitaxel 200 mg/m(2), and bevacizumab 15 mg/kg, and was continued on every-3-week maintenance bevacizumab 15 mg/kg. The patient underwent glass dry cupping during cycle six of maintenance bevacizumab treatment without overt cutaneous adverse events or bleeding. The patient did not realize he should have communicated his cupping plans or recent bevacizumab treatment with his providers.

  18. Acetabular Cup Revision.

    Science.gov (United States)

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  19. Hydroponic Feed With Suction

    Science.gov (United States)

    Cox, William M.; Brown, Christopher S.; Dreschel, Thomas W.

    1994-01-01

    Placing nutrient solution under suction increases growth. Foam plug seals growing stem of plant, making it possible to maintain suction in nutrient liquid around roots. Jar wrapped in black tape to keep out light. Potential use in terrestrial applications in arid climates or in labor-intensive agricultural situations.

  20. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear...... viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three...

  1. Suction is kid's play: extremely fast suction in newborn seahorses

    Science.gov (United States)

    Van Wassenbergh, Sam; Roos, Gert; Genbrugge, Annelies; Leysen, Heleen; Aerts, Peter; Adriaens, Dominique; Herrel, Anthony

    2009-01-01

    Ongoing anatomical development typically results in a gradual maturation of the feeding movements from larval to adult fishes. Adult seahorses are known to capture prey by rotating their long-snouted head extremely quickly towards prey, followed by powerful suction. This type of suction is powered by elastic recoil and requires very precise coordination of the movements of the associated feeding structures, making it an all-or-none phenomenon. Here, we show that newborn Hippocampus reidi are able to successfully feed using an extremely rapid and powerful snout rotation combined with a high-volume suction, surpassing that observed in adult seahorses. An inverse dynamic analysis shows that an elastic recoil mechanism is also used to power head rotation in newborn H. reidi. This illustrates how extreme levels of performance in highly complex musculoskeletal systems can be present at birth given a delayed birth and rapid development of functionally important structures. The fact that the head skeleton of newborn seahorses is still largely cartilaginous may not be problematic because the hydrodynamic stress on the rotating snout appeared considerably lower than in adult syngnathids. PMID:19324657

  2. PERBEDAAN PARAMETER KARDIOPULMONAL SETELAH TINDAKAN OPEN SUCTION

    Directory of Open Access Journals (Sweden)

    Muhamat Nofiyanto

    2013-12-01

    Full Text Available Background: Endotracheal suctioning is often performed by nurses and beneficial for critically ill patients. Suctioning is essential for removing secretions, maintaining airway patency and prevent unexpected complications. Open suctioning is performed by disconnecting patients with the ventilator. Suctioning not only removed secretions in the airway but also oxygen. Suctioning must be done correctly, safely, effectively and efficiently to prevent unexpected events in critically ill patients. Objective: This study aimed to determine differences on cardiopulmonary parameters after open suction in critically ill patients Methods: The study design was comparatif cross sectional analytic approach, using one group pre test and post test. The sample of the research amounted to 34 people, using purposive sampling technique. Catheter size 14 Fr on ETT number 7 mm used in this research to performed endotracheal suctioning. Cardiopulmonary parameters (Heart rate/ HR, respiratory rate/RR, oxygen saturation/SpO2, systolic blood pressure/ SBP and diastolic blood pressure/DBP measured by pulse oxymeter and bedside monitor before suction and immediately thereafter. Results: The results showed increase average heart rate 6.412 (from 106.62 into 113.03, Respiratory rate has increased 4.971 (from 20.62 into 25.59, SpO2 decreased 1.68 (from 99.09 into 97.41, and systolic blood pressure increased 5.71 (from 118.29 into 124.00 after performed open suction. The results of paired t-test statistical analysis (for RR, HR obtained a < 0.05 (0.000, whereas Wilcoxon statistical analysis (for SpO2, SBP obtained a < 0.05 (0.000 and 0.001. So it can be said that the difference cardiopulmonary parameters was statistically significant after perfomed open suction in critically ill patients.

  3. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.

    Science.gov (United States)

    Gillies, Donna; Spence, Kaye

    2011-07-06

    Mechanical ventilation is commonly used in Neonatal Intensive Care Units to assist breathing in a variety of conditions. Mechanical ventilation is achieved through the placement of an endotracheal tube (ETT) which is left in-situ. The ETT is suctioned to prevent a build-up of secretions and blockage of the airway. Methods of suctioning the endotracheal tube vary according to institutional practice and the individual clinician performing the task. The depth of suctioning is one of these variables. The catheter may be passed to the tip of the ETT or beyond the tip into the trachea or bronchi to facilitate removal of secretions. However, trauma to the lower airways may result from the suction catheter being passed into the airway beyond the tip of the endotracheal tube. To compare the effectiveness and complications of deep (catheter passed beyond the tip of the ETT) versus shallow (catheter passed to length of ETT only) suctioning of the endotracheal tube in ventilated infants. In this first update the searches were expanded to the Cochrane Central Register of Controlled Trials (The Cochrane Library, March 30), MEDLINE (from January 1966 to May 30 2011), CINAHL (from 1982 to May 30 2011) and EMBASE (1980 to May 2011) using text words and subject headings relevant to endotracheal suctioning. There were no language restrictions. Controlled trials using random or quasi-random allocation of neonates receiving ventilatory support via an endotracheal tube to either deep or shallow endotracheal suctioning. The updated search resulted in 149 potentially relevant references. Two of the studies from this search were identified as potentially relevant. We included one of the potentially relevant studies and the other was excluded because it did not fit the inclusion criteria. One small crossover trial (n = 27) of shallow versus deep suctioning met the criteria for inclusion in this review. The reported outcomes were oxygen saturation and heart rate, during and after suctioning

  4. Suction caissons subjected to monotonic combined loading

    DEFF Research Database (Denmark)

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation...... for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to analyse the behaviour of suction caissons for offshore wind turbines subjected to combined loading. Finite element...

  5. Scaled multiple holes suction tip for microneurosurgery; Technical note

    Directory of Open Access Journals (Sweden)

    Abdolkarim Rahmanian, Associate Professor of Neurosurgery

    2017-12-01

    Conclusion: The new suction tip permits easy and precise adjustment of suction power in microneurosirgical operations. Our scaled 3 and 4-hole suction tip is a simple and useful device for controlling the suction power during the microneurosurgeical procedures.

  6. The translational regulator Cup controls NMJ presynaptic terminal morphology.

    Science.gov (United States)

    Menon, Kaushiki P; Carrillo, Robert A; Zinn, Kai

    2015-07-01

    During oogenesis and early embryonic development in Drosophila, translation of proteins from maternally deposited mRNAs is tightly controlled. We and others have previously shown that translational regulatory proteins that function during oogenesis also have essential roles in the nervous system. Here we examine the role of Cup in neuromuscular system development. Maternal Cup controls translation of localized mRNAs encoding the Oskar and Nanos proteins and binds to the general translation initiation factor eIF4E. In this paper, we show that zygotic Cup protein is localized to presynaptic terminals at larval neuromuscular junctions (NMJs). cup mutant NMJs have strong phenotypes characterized by the presence of small clustered boutons called satellite boutons. They also exhibit an increase in the frequency of spontaneous glutamate release events (mEPSPs). Reduction of eIF4E expression synergizes with partial loss of Cup expression to produce satellite bouton phenotypes. The presence of satellite boutons is often associated with increases in retrograde bone morphogenetic protein (BMP) signaling, and we show that synaptic BMP signaling is elevated in cup mutants. cup genetically interacts with two genes, EndoA and Dap160, that encode proteins involved in endocytosis that are also neuronal modulators of the BMP pathway. Endophilin protein, encoded by the EndoA gene, is downregulated in a cup mutant. Our results are consistent with a model in which Cup and eIF4E work together to ensure efficient localization and translation of endocytosis proteins in motor neurons and control the strength of the retrograde BMP signal. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Evaluation of hypopharyngeal suction to eliminate aspiration: the Retro-Esophageal Suction (REScue) catheter.

    Science.gov (United States)

    Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M

    2015-02-01

    Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p  0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p 12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.

  8. Dynamic lateral response of suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara

    2017-01-01

    Deeper water installations of offshore wind turbines may be supported by jacket structures. This study investigates the dynamic response of suction caissons for jackets by analysing 3D finite element models in the frequency domain. The numerical modelling was firstly validated by analytical...... solutions for pile foundations. Groups of crucial dimensionless parameters related to the soil profile and the foundation geometry are identified and their effects on the response of suction caissons are studied. Static stiffness coefficients are presented in a form of mathematical formulas obtained...... by fitting the numerical results, pertaining foundations with different slenderness ratios and embedded in different soil profiles. Sensitivity of the dynamic impedances of suction caissons on the skirt length was showed in this study. Moreover, the results for the suction caissons indicated that the overall...

  9. Menses cup evaluation study.

    Science.gov (United States)

    Cheng, M; Kung, R; Hannah, M; Wilansky, D; Shime, J

    1995-09-01

    To determine whether the menses cup is well tolerated by menstruating women. Prospective descriptive clinical study. Normal human volunteers in an academic research environment. Fifty-one menstruating women recruited between June to December 1991. Each participant was provided with two menses cups and an instruction sheet. Baseline information, including age, occupation, martial status, parity, description of menstrual flow, and current method used to cope with menstrual flow was collected. Subjects were asked to describe their experience with the cup at 1-, 2-, 6-, and 12-month intervals. The proportion of women who found the cup acceptable. The cup was used by 51 subjects for a total of 159 cycles. Overall, 23 women (45%) found the cup an acceptable method for coping with menses. Among 29 (57%) women who used the cup for two or more cycles, 62% found it acceptable. The menses cup may be an acceptable method for some women for coping with menstrual flow.

  10. [Innovation of characteristic medicinal cupping devices].

    Science.gov (United States)

    Li, Jianping; Zhang, Hui; Yang, Jianmei; Xu, Xinchun; Niu, Yanxia; Cai, Jun

    2015-08-01

    To compare the differences in the characteristic medicinal cupping therapy between the traditional cupping device and the innovated cupping device. Fifty patients of neck and low back pain were selected. The self-comparison was adopted. The cupping therapy was applied to the acupoints located on the left or right side with the traditional cupping device and the innovated cupping device. The cupping sites were centered at bilateral Quyuan (SI 13) and Dachangshu (BL 25). The cups were retained for 10 min. The traditional cupping device was the glass with smooth border, 100mL. The innovated cupping device was the vacuum-sucking cup. The operative time, medicinal leakage, comfort and cupping marks were observed for the two different cupping devices. The operative time with the innovated medicinal cupping device was shorter obviously compared with the traditional one at Quyuan (SI 13) and Dachangshu (BL 25, both Pcupping device was remarkably improved as compared with the traditional one at the two acupoints (both Pcupping operation (both P>0. 05). The cupping marks with the innovated medicinal cupping device were much deeper than those with the traditional one after cupping therapy. The innovated cupping device is more convenent and comfortable in operation during the characteristic medicinal cupping therapy.

  11. From Baby Bottle to Cup: Choose Training Cups Carefully, Use Them Temporarily

    Science.gov (United States)

    FOR THE DENTAL PATIENT ... From baby bottle to cup Choose training cups carefully, use them temporarily T ooth decay can ... should encourage their children to drink from a cup by their first birthday. As you make the ...

  12. Spoon-to-Cup Fading as Treatment for Cup Drinking in a Child with Intestinal Failure

    Science.gov (United States)

    Groff, Rebecca A.; Piazza, Cathleen C.; Zeleny, Jason R.; Dempsey, Jack R.

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup. (Contains 2…

  13. SPOON-TO-CUP FADING AS TREATMENT FOR CUP DRINKING IN A CHILD WITH INTESTINAL FAILURE

    OpenAIRE

    Groff, Rebecca A; Piazza, Cathleen C; Zeleny, Jason R; Dempsey, Jack R

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup.

  14. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    Science.gov (United States)

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  15. Suction caissons subjected to monotonic combined loading

    OpenAIRE

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to anal...

  16. Assessment of Feasibility of Suction Pile/Anchor Installation and Pullout Testing through Field Tests

    Directory of Open Access Journals (Sweden)

    R. Vijaya

    2014-09-01

    Full Text Available Suction pile anchors are large cylindrical (inverted bucket type structure open at the bottom and closed at the top and largely used for mooring of offshore platforms, exploratory vessels etc. Prediction of the mooring capacity of suction piles is a critical issue faced by the design engineers and rational methods are required to produce reliable designs. Tests have been conducted in an existing natural pond within NIOT campus with the objective of developing methodology of deployment, design and logistics for suction pile installation and testing of mooring capacity under static pullout. Small size suction piles with varying diameters and lengths have been used in the tests. The tests have been carried out in the natural pond with constant water depth of 1.5 m with the top 1.5 m layer of bed comprising soft marine clay. It is found that pile geometry, aspect ratio and angle of pullout have a significant influence on the response to pullout. As angle of mooring load application changes from vertical to horizontal the reaction offered by the suction pile changes from skin friction to passive soil resistance. Resistance offered by the internal plug of soil is found to vary according to dimension of the anchor piles.

  17. Cup tool use by squirrel monkeys.

    Science.gov (United States)

    Buckmaster, Christine L; Hyde, Shellie A; Parker, Karen J; Lyons, David M

    2015-12-01

    Captive-born male and female squirrel monkeys spontaneously 'invented' a cup tool use technique to Contain (i.e., hold and control) food they reduced into fragments for consumption and to Contain water collected from a valve to drink. Food cup use was observed more frequently than water cup use. Observations indicate that 68% (n = 39/57) of monkeys in this population used a cup (a plastic slip cap) to Contain food, and a subset of these monkeys, 10% (n = 4/39), also used a cup to Contain water. Cup use was optional and did not replace, but supplemented, the hand/arm-to-mouth eating and direct valve drinking exhibited by all members of the population. Strategies monkeys used to bring food and cups together for food processing activity at preferred upper-level perching areas, in the arboreal-like environment in which they lived, provides evidence that monkeys may plan food processing activity with the cups. Specifically, prior to cup use monkeys obtained a cup first before food, or obtained food and a cup from the floor simultaneously, before transporting both items to upper-level perching areas. After food processing activity with cups monkeys rarely dropped the cups and more often placed the cups onto perching. Monkeys subsequently returned to use cups that they previously placed on perching after food processing activity. The latter behavior is consistent with the possibility that monkeys may keep cups at preferred perching sites for future food processing activity and merits experimental investigation. Reports of spontaneous tool use by squirrel monkeys are rare and this is the first report of population-level tool use. These findings offer insights into the cognitive abilities of squirrel monkeys and provide a new context for behavior studies with this genus and for comparative studies with other primates. © 2015 Wiley Periodicals, Inc.

  18. Boundary layer on a flat plate with suction

    International Nuclear Information System (INIS)

    Favre, A.; Dumas, R.; Verollet, E.

    1961-01-01

    This research done in wind tunnel concerns the turbulent boundary layer of a porous flat plate with suction. The porous wall is 1 m long and begins 1 m downstream of the leading edge. The Reynolds number based on the boundary layer thickness is of the order of 16.300. The suction rate defined as the ratio of the velocity perpendicular to the wall to the external flow velocity ranges from 0 to 2 per cent. The pressure gradient can be controlled. The mean velocity profiles have been determined for various positions and suction rates by means of total pressure probes together with the intensities of the turbulent velocity fluctuations components, energy spectra and correlations by means of hot wire anemometers, spectral analyser and correlator. The stream lines, the values of the viscous and turbulent shear stresses, of the local wall friction, of the turbulent energy production term, with some information on the dissipation of the energy have been derived from these measurements. For these data the integral of equation of continuity in boundary layer have been drawn. The suction effects on the boundary layer are important. The suction thoroughly alters the mean velocity profiles by increasing the viscous shear stresses near the wall and decreasing them far from the wall, it diminishes the longitudinal and transversal turbulence intensities, the turbulent shear stresses, and the production of energy of turbulence. These effects are much stressed in the inner part of the boundary layer. On the other hand the energy spectra show that the turbulence scale is little modified, the boundary layer thickness being not much diminished by the suction. The suction effects can be appreciated by comparing twice the suction rate to the wall friction coefficient (assumed airtight), quite noticeable as soon as the rate is about unity, they become very important when it reaches ten. (author) [fr

  19. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection.

    Science.gov (United States)

    Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C

    2015-10-01

    Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces

  20. Suction power output and the inertial cost of rotating the neurocranium to generate suction in fish.

    Science.gov (United States)

    Van Wassenbergh, Sam; Day, Steven W; Hernández, L Patricia; Higham, Timothy E; Skorczewski, Tyler

    2015-05-07

    To expand the buccal cavity, many suction-feeding fishes rely on a considerable contribution from dorsal rotation of the dorsal part of the head including the brains, eyes, and several bones forming the braincase and skull roof (jointly referred to as the neurocranium). As the neurocranium takes up a large part of the total mass of the head, this rotation may incur a considerable inertial cost. If so, this would suggest a significant selective pressure on the kinematics and mass distribution of the neurocranium of suction feeders. Here, an inverse dynamic model is formulated to calculate the instantaneous power required to rotate the neurocranium, approximated by a quarter ellipsoid volume of homogeneous density, as well as to calculate the instantaneous suction power based on intra-oral pressure and head volume quantifications. We applied this model to largemouth bass (Micropterus salmoides) and found that the power required to rotate the neurocranium accounts for only about 4% of the power required to suck water into the mouth. Furthermore, recovery of kinetic energy from the rotating neurocranium converted into suction work may be possible during the phase of neurocranial deceleration. Thus, we suggest that only a negligible proportion of the power output of the feeding muscles is lost as inertial costs in the largemouth bass. Consequently, the feeding performance of piscivorous suction feeders with generalised morphology, comparable to our model species, is not limited by neurocranial motion during head expansion. This suggests that it is thus not likely to be a factor of importance in the evolution of cranial shape and size. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Suction v. conventional curettage in incomplete abortion

    African Journals Online (AJOL)

    Suction v. conventional curettage in incomplete abortion. A randomised controlled trial. D. A. A. VERKUYL, C. A. CROWTHER .Abstract This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients ...

  2. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  3. Vortical and acoustical mode coupling inside a porous tube with uniform wall suction.

    Science.gov (United States)

    Jankowskia, T A; Majdalani, J

    2005-06-01

    This paper considers the oscillatory motion of gases inside a long porous tube of the closed-open type. In particular, the focus is placed on describing an analytical solution for the internal acoustico-vortical coupling that arises in the presence of appreciable wall suction. This unsteady field is driven by longitudinal oscillatory waves that are triggered by small unavoidable fluctuations in the wall suction speed. Under the assumption of small amplitude oscillations, the time-dependent governing equations are linearized through a regular perturbation of the dependent variables. Further application of the Helmholtz vector decomposition theorem enables us to discriminate between acoustical and vortical equations. After solving the wave equation for the acoustical contribution, the boundary-driven vortical field is considered. The method of matched-asymptotic expansions is then used to obtain a closed-form solution for the unsteady momentum equation developing from flow decomposition. An exact series expansion is also derived and shown to coincide with the numerical solution for the problem. The numerically verified end results suggest that the asymptotic scheme is capable of providing a sufficiently accurate solution. This is due to the error associated with the matched-asymptotic expansion being smaller than the error introduced in the Navier-Stokes linearization. A basis for comparison is established by examining the evolution of the oscillatory field in both space and time. The corresponding boundary-layer behavior is also characterized over a range of oscillation frequencies and wall suction velocities. In general, the current solution is found to exhibit features that are consistent with the laminar theory of periodic flows. By comparison to the Sexl profile in nonporous tubes, the critically damped solution obtained here exhibits a slightly smaller overshoot and depth of penetration. These features may be attributed to the suction effect that tends to

  4. Efficacy of cupping therapy in patients with the fibromyalgia syndrome-a randomised placebo controlled trial.

    Science.gov (United States)

    Lauche, Romy; Spitzer, Julia; Schwahn, Barbara; Ostermann, Thomas; Bernardy, Kathrin; Cramer, Holger; Dobos, Gustav; Langhorst, Jost

    2016-11-17

    This study aimed to test the efficacy of cupping therapy to improve symptoms and quality of life in patients diagnosed with the fibromyalgia syndrome. Participants were randomly assigned to cupping therapy, sham or usual care. Cupping was administered five times at twice weekly intervals on the upper and lower back. The primary outcome measure was pain intensity at day 18. Secondary outcomes included functional disability, quality of life, fatigue and sleep quality as well as pressure pain sensitivity, satisfaction and safety at day 18 and 6 months. Altogether 141 patients were included in this study (139 females, 55.8 ± 9.1 years). After 18 days patients reported significant less pain after cupping compared to usual care (difference -12.4; 95% CI: -18.9; -5.9, p cupping and sham cupping; and only minor side effects were observed. Despite cupping therapy being more effective than usual care to improve pain intensity and quality of life, effects of cupping therapy were small and comparable to those of a sham treatment, and as such cupping cannot be recommended for fibromyalgia at the current time.

  5. Is cupping blister harmful?-A proteomical analysis of blister fluid induced by cupping therapy and scald.

    Science.gov (United States)

    Liu, Zhidan; Chen, Chunlan; Li, Xiaoyan; Zhao, Chuang; Li, Zunyuan; Liang, Wei; Lin, Yufang

    2018-02-01

    Cupping therapy has a long history in traditional medicine especially in Asian countries. It was controversial whether cupping induced blisters are beneficial to healing effects, and the formation and content in the blisters remain unexplored. We aimed to identify and compare the molecular components of the blister fluid from the cupping therapy and the scalds to explore the necessary of inducing cupping induced blisters. Fluid sample of blisters from fifteen patients receiving cupping therapy (Cupping group) and scald burns (Scald group) were collected in this study. Proteins from the blisters were separated by two-dimensional electrophoresis (2D-gel) and further analyzed by mass spectrometry. In addition, the changes in particular proteins were confirmed by Western blotting. The protein components are significantly different between blister from cupping therapy and scalds. The immune responses, oxidative stress and metabolic related proteins (Ig lambda-2 chain C regions, Ig gamma-1 chain C region, hemopexin, prdx2, calmodulin, succinyl-CoA ligase and tetranectin) were increased, whereas the hemoglobin subunit beta was decreased in the Cupping group compared with the Scald group. Cupping induced blisters contain several proteins which relate to the activation of certain immune pathways including anti-oxidation, anti-apoptosis, tissue repairing and metabolic regulation. This proteomic analysis may indicate a significant clue to the mechanism study of cupping. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The CUP2 gene product regulates the expression of the CUP1 gene, coding for yeast metallothionein.

    OpenAIRE

    Welch, J; Fogel, S; Buchman, C; Karin, M

    1989-01-01

    The yeast CUP1 gene codes for a copper-binding protein similar to metallothionein. Copper sensitive cup1s strains contain a single copy of the CUP1 locus. Resistant strains (CUP1r) carry 12 or more multiple tandem copies. We isolated 12 ethyl methane sulfonate-induced copper sensitive mutants in a wild-type CUP1r parental strain, X2180-1A. Most mutants reduce the copper resistance phenotype only slightly. However, the mutant cup2 lowers resistance by nearly two orders of magnitude. We cloned ...

  7. Factitious panniculitis induced by cupping therapy.

    Science.gov (United States)

    Moon, Suk-Ho; Han, Hyun-Ho; Rhie, Jong-Won

    2011-11-01

    Cupping therapy is an alternative medical procedure that has been widely performed in Asian countries to relieve pain. It is known that there is no complication to this therapy, so many non-health care professionals have performed this procedure. However, there have been few reports on complications, such as iron deficiency anemia, hemorrhagic bullae, kelloids, vasovagal syncope, and foreign body reactions. Masses associated with panniculitis induced by cupping are extremely rare, and they require a unique approach.A 56-year-old woman presented with a 10-month history of multiple masses in the posterior neck and right shoulder areas. The patient repeatedly attempted cupping therapy by herself, and multiple palpable masses developed in the posterior neck and right shoulder area where cupping therapy had been performed. The masses were enlarged by repeated cupping, and they decreased in size when cupping was stopped. Among all lesions, the 2 masses with tenderness were surgically excised. The remaining masses resolved after cupping therapy was ceased. When a patient with subcutaneous mass has a history of cupping or trace of cupping marks, panniculitis induced by cupping should be suspected. The lesion seems to spontaneously resolve unless they are repeatedly stimulated. However, surgical resection is considered in patients with infections or severe tenderness as a complication.

  8. Yeast CUP1 protects HeLa cells against copper-induced stress

    Energy Technology Data Exchange (ETDEWEB)

    Xie, X.X. [Department of Animal Sciences, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai (China); Shanghai Key Laboratory of Veterinary Biotechnology, Shanghai (China); College of Biological and Environmental Engineering, Zhejiang University of Technology, Hangzhou (China); Ma, Y.F.; Wang, Q.S.; Chen, Z.L.; Liao, R.R.; Pan, Y.C. [Department of Animal Sciences, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai (China); Shanghai Key Laboratory of Veterinary Biotechnology, Shanghai (China)

    2015-06-12

    As an essential trace element, copper can be toxic in mammalian cells when present in excess. Metallothioneins (MTs) are small, cysteine-rich proteins that avidly bind copper and thus play an important role in detoxification. YeastCUP1 is a member of the MT gene family. The aim of this study was to determine whether yeast CUP1 could bind copper effectively and protect cells against copper stress. In this study,CUP1 expression was determined by quantitative real-time PCR, and copper content was detected by inductively coupled plasma mass spectrometry. Production of intracellular reactive oxygen species (ROS) was evaluated using the 2',7'-dichlorofluorescein-diacetate (DCFH-DA) assay. Cellular viability was detected using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, and the cell cycle distribution of CUP1 was analyzed by fluorescence-activated cell sorting. The data indicated that overexpression of yeast CUP1 in HeLa cells played a protective role against copper-induced stress, leading to increased cellular viability (P<0.05) and decreased ROS production (P<0.05). It was also observed that overexpression of yeast CUP1 reduced the percentage of G1 cells and increased the percentage of S cells, which suggested that it contributed to cell viability. We found that overexpression of yeast CUP1 protected HeLa cells against copper stress. These results offer useful data to elucidate the mechanism of the MT gene on copper metabolism in mammalian cells.

  9. Forecasting a winner for Malaysian Cup 2013 using soccer simulation model

    Science.gov (United States)

    Yusof, Muhammad Mat; Fauzee, Mohd Soffian Omar; Latif, Rozita Abdul

    2014-07-01

    This paper investigates through soccer simulation the calculation of the probability for each team winning Malaysia Cup 2013. Our methodology used here is we predict the outcomes of individual matches and then we simulate the Malaysia Cup 2013 tournament 5000 times. As match outcomes are always a matter of uncertainty, statistical model, in particular a double Poisson model is used to predict the number of goals scored and conceded for each team. Maximum likelihood estimation is use to measure the attacking strength and defensive weakness for each team. Based on our simulation result, LionXII has a higher probability in becoming the winner, followed by Selangor, ATM, JDT and Kelantan. Meanwhile, T-Team, Negeri Sembilan and Felda United have lower probabilities to win Malaysia Cup 2013. In summary, we find that the probability for each team becominga winner is small, indicating that the level of competitive balance in Malaysia Cup 2013 is quite high.

  10. Advances on development of suction and temperature controlled oedometer cell

    International Nuclear Information System (INIS)

    Ye Weimin; Zhang Yawei; Chen Bao; Wang Min

    2010-01-01

    Oedometer cells for unsaturated soils can be classified into two types, that is, conventional unsaturated oedometer cells (high-suction unsaturated oedometer cell, high-suction and high-pressure unsaturated oedometer cell) and temperature controlled unsaturated oedometer cells. Among them, the osmotic, vapor equilibrium and axis translation techniques are often employed for suction control. The thermostat bath method and thermostatically controlled heater method are commonly used for temperature control. The lever loading system, hydraulic loading system and air pressure loading system are commonly means used for vertical pressure. Combination of osmotic (or axis translation) technique with vapor equilibrium method employed for the full range suction control, thermostatically liquid temperature control method, and the hydraulic loading system, could be used for suction, temperature and loading control in the design for unsaturated oedometer cells in the future, which can be used for study of buffer/backfill materials under high-temperature, high pressure and full range suction conditions. (authors)

  11. Kinematics of suction feeding in the seahorse Hippocampus reidi.

    Science.gov (United States)

    Roos, Gert; Van Wassenbergh, Sam; Herrel, Anthony; Aerts, Peter

    2009-11-01

    Fish typically use a rostro-caudal wave of head expansion to generate suction, which is assumed to cause a uni-directional, anterior-to-posterior flow of water in the expanding head. However, compared with typical fish, syngnathid fishes have a remarkably different morphology (elongated snout, small hyoid, immobile pectoral girdle) and feeding strategy (pivot feeding: bringing the small mouth rapidly close to the prey by neurocranial dorsorotation). As a result, it is unclear how suction is generated in Syngnathidae. In this study, lateral and ventral expansions of the head were quantified in Hippocampus reidi and linked to the kinematics of the mouth, hyoid and neurocranium. In addition, the flow velocities inside the bucco-pharyngeal cavity and in front of the mouth were calculated. Our data suggest that the volume changes caused by lateral expansion are dominant over ventral expansion. Maximum gape, neurocranium rotation and hyoid depression are all reached before actual volume increase and before visible prey movement. This implies that, unlike previously studied teleosts, hyoid rotation does not contribute to ventral expansion by lowering the floor of the mouth during prey capture in H. reidi. The lateral volume changes show a rostro-caudal expansion, but the maximal flow velocity is not near the mouth aperture (as has been demonstrated for example in catfish) but at the narrow region of the buccal cavity, dorsal to the hyoid.

  12. Dynamic Behaviour of Suction Caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten

    to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary...... in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil...

  13. Investigation of suction anchor pullout capacity under undrained conditions

    OpenAIRE

    Jarand, Pollestad

    2015-01-01

    Master's thesis in Offshore technology Floating units are dependent on reliable mooring systems to ensure safety during marine operations. Suction anchors have proved to be a technologically viable and cost-effective concept. They are capable of precision installation, re-use, and provide large resistive capacity. This thesis investigates load capacity and failure modes of suction anchors subjected to vertical, horizontal (lateral), and incline loading. Suction anchor design co...

  14. Enhanced effect of suction-cavitation on the ozonation of phenol

    International Nuclear Information System (INIS)

    Wu Zhilin; Franke, Marcus; Ondruschka, Bernd; Zhang, Yongchun; Ren Yanze; Braeutigam, Patrick; Wang, Weimin

    2011-01-01

    800 mL of 1.0 mM phenol-containing aqueous solution was circulated at 20 ° C for 30 min in a suction-reactor, while 3.2 mg min -1 ozone was introduced into the solution under the suction orifice. The removal rates of phenol vary polynomially with the orifice diameter as well as the suction pressure. The rate constant for the zero-order kinetics achieves the highest value at -0.070 MPa by using 5 mm orifice. Although the suction-cavitation alone cannot remove phenol in 30 min, it can considerably enhance the ozonation of phenol. The rate constants for the zero-order kinetics by the simple ozonation and the combined method are 0.018 and 0.028 min -1 , respectively. Furthermore, no ozone was observed in the tail gas during the first 15 min for the ozonation in the suction reactor, and then the concentration of unreacted ozone slowly increased, indicating that the utilization rate of ozone is significantly improved by the suction-cavitation. The increasing input concentration of ozone obviously accelerates the ozonation of phenol, but the total required quantities of ozone are very close by various ozone input concentrations to reach the same degradation rate, indicating the ozonation assisted by the suction-cavitation can be considered as a quantitative reaction.

  15. Numerical simulation and experimental investigation on suction heating of a BOG compressor

    International Nuclear Information System (INIS)

    Jia, Xiaohan; Zhao, Bin; Feng, Jianmei; Zheng, Sulu; Peng, Xueyuan

    2016-01-01

    Highlights: • An investigation focusing on suction heating of a BOG compressor is carried out. • There is frost on the cylinder cover as the compressor at lower suction temperature. • The suction and discharge flow rate decrease with rising suction temperature. • The volumetric efficiency has a maximum value with increasing suction temperature. • The temperature coefficient increased with suction temperature or rotational speed. - Abstract: One of the key components of a liquefied natural gas (LNG) receiving terminal is the boil-off gas (BOG) compressor, which is used to pump out the BOG from the LNG storage tank to ensure safety in the transportation and receiving systems. Owing to the ultra-low suction temperature, the heat exchange between the intake gas and the cylinder, piston, and cylinder cover cannot be ignored as in normal conditions. This paper presents an investigation focusing on suction heating of the BOG compressor. A finite element model with dynamic mesh was established to simulate the suction process. At the same time, a performance test rig was built to study the characteristics of the BOG compressor under low suction temperature conditions and verify the numerical model. Consequently, the results of the simulation were in good agreement with experimental results. Both results implied that the temperature of cylinder surface increased starting from the cylinder cover to the crankcase. In addition, at lower suction temperature, the temperature difference between various points on the cylinder surface and cylinder cover was much larger than that at higher suction temperature. With increasing suction temperature, the temperature coefficient increased markedly, and the difference between gas temperatures at the beginning and end of the suction process, as well as the compressor flow rate, decreased significantly; however, the volumetric efficiency increased first and then decreased. Furthermore, the temperature coefficient clearly increased

  16. The Evolution of the Cup-Cage Technique for Major Acetabular Defects: Full and Half Cup-Cage Reconstruction.

    Science.gov (United States)

    Sculco, Peter K; Ledford, Cameron K; Hanssen, Arlen D; Abdel, Matthew P; Lewallen, David G

    2017-07-05

    Complex acetabular reconstruction for major bone loss can require advanced methods such as the use of a cup-cage construct. The purpose of this study was to review outcomes after the initial development of the cup-cage technique and the subsequent evolution to the use of a half cup-cage construct. We performed a retrospective, single-center review of 57 patients treated with cup-cage reconstruction for major acetabular bone loss. All patients had major acetabular defects graded as Paprosky Type 2B through 3B, with 34 (60%) having an associated pelvic discontinuity. Thirty patients received a full cup-cage construct and 27, a half cup-cage construct. The mean follow-up was 5 years. Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip score (HHS) values, from 36 to 72 at a minimum of 2 years of follow-up (p cup-cage constructs and 6 (22%) of the half cup-cage constructs. One patient with a full cup-cage construct underwent re-revision of the acetabular component for progressive migration and aseptic loosening. Short-term survivorship free from re-revision for any cause or reoperation was 89% (83% and 96% for full and half cup-cage cohorts, respectively). Both full and half cup-cage constructs demonstrated successful clinical outcomes and survivorship in the treatment of major acetabular defects and pelvic discontinuity. Each method is utilized on the basis of individual intraoperative findings, including the extent and pattern of bone loss, the quality and location of host bone remaining after preparation, and the presence of pelvic discontinuity. Longer-term follow-up is required to understand the durability of these constructs in treating major acetabular defects and pelvic discontinuity. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  17. Second-order motor planning in children: insights from a cup-manipulation-task.

    Science.gov (United States)

    Wunsch, Kathrin; Weiss, Daniel J; Schack, Thomas; Weigelt, Matthias

    2015-07-01

    The present study examined the development of anticipatory motor planning in an object manipulation task that has been used to successfully demonstrate motor planning in non-human primates (Weiss et al. in Psychol Sci 18:1063-1068, 2007). Seventy-five participants from four different age groups participated in a cup-manipulation task. One group was preschool children (average age of 5.1 years), two groups were primary school children (7.7 and 9.8 years old respectively) and the final group was comprised of adults. The experimental task entailed reaching for a plastic cup that was vertically suspended in an apparatus in either upright or inverted orientation, removing the cup by its stem and then retrieving a small toy from the inside of the cup. When the cup was inverted in the apparatus, evidence for anticipatory motor planning could be achieved by initially gripping the stem using an inverted (thumb-down) grip posture. We found that when the cup was in upright orientation, all participants reached for the cup using an upright grip (i.e., thumb-up posture). However, when the cup was inverted in the apparatus, only adults consistently used an inverted grasping posture, though the percentage of inverted grips among participants did increase with age. These results suggest a protracted development for anticipatory motor planning abilities in children. Surprisingly, the performance of adults on this task more closely resembles the performance of several nonhuman primate species as opposed to children even at approximately 10 years of age. We discuss how morphological constraints on flexibility may help account for these findings.

  18. Radiology in Gerard uncemented double cup arthroplasty

    International Nuclear Information System (INIS)

    Willems, W.J.; Rozing, P.M.; Obermann, W.R.

    1988-01-01

    A radiological follow-up was performed on 109 Gerard (uncemented) double cup arthroplasties, with special emphasis on shift of the femoral cup and protrusion of the acetabular cup, for which a new formula was introduced. Varus shift or axial collapse of the femoral cup played a major role in the failure of these cups. Fluoroscopic examination with video-tape recording seemed to be most helpful in determining abnormalities in this kind of arthroplasty. This examination revealed one normal and two abnormal types of movement, either between both cups or between acetabular cup and acetabular cavity. Those hips with normal movement showed a significantly better clinical score. 16 refs.; 6 figs

  19. On equations for the total suction and its matric and osmotic components

    International Nuclear Information System (INIS)

    Dao, Vinh N.T.; Morris, Peter H.; Dux, Peter F.

    2008-01-01

    A clear fundamental understanding of suctions is crucial for the study of the behaviour of plastic cement mortar and concrete, including plastic shrinkage cracking. In this paper, the expression relating the change in free energy of the pore water with an isothermal change in pressure is first derived. Based upon definitions of suctions, it is then shown that total, matric, and osmotic suctions can all be expressed in the same thermodynamic form. The widely accepted, but not yet satisfactorily validated, assumption that the total suction comprises matric and osmotic components is then confirmed theoretically. The well-known Kelvin equation for matric suction, and Morse and van't Hoff equations for osmotic suction are subsequently derived from the corresponding thermodynamic equations. The applicability of latter two equations in evaluating the osmotic suctions of cement mortar and concrete is highlighted

  20. Suction v. conventional curettage in incomplete abortion A ...

    African Journals Online (AJOL)

    This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients undergoing suction curettage had a significantly lower intra-operative blood loss (P < 0,0001) and a significantly higher mean ...

  1. Calculations for the excitation functions of the 63Cup, n63Zn, 63Cup, 2n62Zn and 65Cup, n65Zn reactions

    International Nuclear Information System (INIS)

    Gul, K.

    2001-01-01

    Calculations for the excitation functions of 63 Cup, n 63 Zn, 63 Cup, 2n 62 Zn and 65 Cup, n 65 Zn reactions have been carried out in 3-30 MeV energy range using statistical and pre-equilibrium nuclear reaction models. The calculations have been compared with reported measurements and discussed

  2. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Mortensen, Niels Gylling; Hansen, Jens Carsten

    2007-01-01

    A field calibration method and results are described along with the experience gained with the method. The cup anemometers to be calibrated are mounted in a row on a 10-m high rig and calibrated in the free wind against a reference cup anemometer. The method has been reported [1] to improve...... the statistical bias on the data relative to calibrations carried out in a wind tunnel. The methodology is sufficiently accurate for calibration of cup anemometers used for wind resource assessments and provides a simple, reliable and cost-effective solution to cup anemometer calibration, especially suited...

  3. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  4. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  5. Development of standard practice guidelines for open and closed system suctioning.

    Science.gov (United States)

    Özden, Dilek; Görgülü, R Selma

    2012-05-01

    This study was carried out to determine the knowledge and practice of nurses before and after training and the development of standard practice guidelines for open and closed system suctioning methods in patients with endotracheal tubes. Many life-threatening complications can occur when a suctioning procedure is not performed with the correct technique. It has been reported that standard practice guidelines for suctioning are insufficient in clinical practice. Non-participant structured observational study. We assessed a total of 48 nurses who were employed in the cardiovascular surgery intensive care unit of a state hospital in Turkey. We used a questionnaire and nurse observation forms to assess the use of the open and closed system suctioning. There was a significant difference between the mean scores of the answers ('true', 'wrong' and 'I do not know') for the use of open and closed system suctioning before and after training. In addition, all steps of both suctioning procedures were carried out correctly during the third observation. The compliance of the nurses to the standard practice guidelines for open and closed suctioning and their knowledge levels on the subject were increased after training, while the implementation of standards was satisfactory. The development of open and closed system suctioning standard practice guidelines directly contributed to the enhancement of patient safety and the quality of nursing care. It is suggested that, as in other nursing care practices, suctioning should be carried out in accordance with standard practice guidelines, and health institutions should develop their standard practice guidelines and work in accordance with them. © 2012 Blackwell Publishing Ltd.

  6. Short-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery.

    Science.gov (United States)

    Mohaddes, Maziar; Rolfson, Ola; Kärrholm, Johan

    2015-02-01

    The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were performed using a TM cup. We compared the risk of reoperation and re-revision for TM cups and the 2 other most frequently used cup designs in acetabular revisions reported to the SHAR. The hypothesis was that the performance of TM cups is as good as that of established designs in the short term. The study population consisted of 2,384 patients who underwent 2,460 revisions during the period 2006 through 2012. The most commonly used cup designs were the press-fit porous-coated cup (n = 870), the trabecular metal cup (n = 805), and the cemented all-polyethylene cup (n = 785). 54% of the patients were female, and the median age at index revision was 72 (19-95) years. Reoperation was defined as a second surgical intervention, and re-revision-meaning exchange or removal of the cup-was used as endpoint. The mean follow-up time was 3.3 (0-7) years. There were 215 reoperations, 132 of which were re-revisions. The unadjusted and adjusted risk of reoperation or re-revision was not significantly different for the TM cup and the other 2 cup designs. Our data support continued use of TM cups in acetabular revisions. Further follow-up is necessary to determine whether trabecular metal cups can reduce the re-revision rate in the long term, compared to the less costly porous press-fit and cemented designs.

  7. Alternative medicine: an update on cupping therapy.

    Science.gov (United States)

    Chen, B; Li, M-Y; Liu, P-D; Guo, Y; Chen, Z-L

    2015-07-01

    To know the research progress of cupping therapy all over the world, the authors analyze the research of cupping therapy in recent 5 years. It indicates that cupping therapy can be applied to extensive curable disease, but has poor clinical evidence. Some improvements in the mechanism research of cupping therapy have been made, but it needs further research. The adverse events of cupping therapy attract attention. The standardization of cupping therapy has emerged. © The Author 2014. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Suction generation in white-spotted bamboo sharks Chiloscyllium plagiosum.

    Science.gov (United States)

    Wilga, Cheryl D; Sanford, Christopher P

    2008-10-01

    After the divergence of chondrichthyans and teleostomes, the structure of the feeding apparatus also diverged leading to alterations in the suction mechanism. In this study we investigated the mechanism for suction generation during feeding in white-spotted bamboo sharks, Chiloscyllium plagiosum and compared it with that in teleosts. The internal movement of cranial elements and pressure in the buccal, hyoid and pharyngeal cavities that are directly responsible for suction generation was quantified using sonomicrometry and pressure transducers. Backward stepwise multiple linear regressions were used to explore the relationship between expansion and pressure, accounting for 60-96% of the variation in pressure among capture events. The progression of anterior to posterior expansion in the buccal, hyoid and pharyngeal cavities is accompanied by the sequential onset of subambient pressure in these cavities as prey is drawn into the mouth. Gape opening triggers the onset of subambient pressure in the oropharyngeal cavities. Peak gape area coincides with peak subambient buccal pressure. Increased velocity of hyoid area expansion is primarily responsible for generating peak subambient pressure in the buccal and hyoid regions. Pharyngeal expansion appears to function as a sink to receive water influx from the mouth, much like that of compensatory suction in bidirectional aquatic feeders. Interestingly, C. plagiosum generates large suction pressures while paradoxically compressing the buccal cavity laterally, delaying the time to peak pressure. This represents a fundamental difference from the mechanism used to generate suction in teleost fishes. Interestingly, pressure in the three cavities peaks in the posterior to anterior direction. The complex shape changes that the buccal cavity undergoes indicate that, as in teleosts, unsteady flow predominates during suction feeding. Several kinematic variables function together, with great variation over long gape cycles to

  9. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  10. Dynamic stiffness of horizontally vibrating suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara; Cisternino, Michele

    2016-01-01

    The promising potential for offshore wind market is on developing wind farms in deeper waters with bigger turbines. In deeper waters the design foundation configuration may consist of jacket structures supported by floating piles or by suction caissons. Taking the soil-structure interaction effects...... into consideration requires the prior estimation of the dynamic impedances of the foundation. Even though numerous studies exist for piles, only limited number of publications can be found for suction caissons subjected to dynamic loads. Therefore, the purpose of this study is to examine the dynamic response...... of this type of foundation using the finite element method (FEM) to account for the interaction with the soil. 3D numerical models for both the soil and the suction caisson are formulated in a frequency domain. The response of the soil surrounding the foundation is considered linear viscoelastic...

  11. A retained menstrual cup.

    Science.gov (United States)

    Day, S

    2012-05-01

    A 20-year-old woman attended a genitourinary clinic with a retained vaginal Mooncup that she had inserted the night before. A Mooncup is one type of menstrual cup. On speculum examination the device was visualized high in the vagina and the cervix appeared firmly lodged within it. The physician experienced difficulty in retrieving the cup despite following product instructions. This case highlights a new adverse event with an increasingly used sanitation product. It is important that clinicians are familiar with the cup, its removal process and are able to counsel patients with retained devices on future correct placement.

  12. Duoplasmatron with a nozzle type plasma expension cup

    International Nuclear Information System (INIS)

    Kobayashi, M.; Nishikawa, T.; Takagi, A.

    1974-01-01

    Various tests are described which were carried out in order to clarify the cause of the aberration existing in the beams extracted from a nozzle type plasma expansion cup. The tests involve the extraction electrodes having different edge shapes, gridded extraction electrodes, high-voltage facing electrodes at the cup exit making different angles with the axis, plasma cups having different contours at the exit, plasma cups gridded at the exit, biasing the cup exit with respect to anode, plasma cups having different ratios of the exit area to axial length, etc. The results show that the inward meniscus type distortion of the plasma boundary near the rim of plasma cup will be a dominant source for the aberration. Both proper shaping of the contour of the cup exit and biasing the cup exit reduced the aberration

  13. Cavitation simulation and NPSH prediction of a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Li, P; Huang, Y F; Li, J

    2012-01-01

    This paper illustrates the flow field numerical analysis of the double-suction centrifugal pump. For the study of the cavitation flow inside the double-suction centrifugal pump, the professional pump/motor simulation software PumpLinx and its Full Cavitation Model has been employed. According to the PumpLinx calculation result and the Cavitation damage index, the cavitation position, level and the cavitation characteristics of the double-suction centrifugal pump has been predicted. For the further objective, the simulation of the flow field in the double-suction centrifugal pump under different inlet conditions has been carried out. By the result analysis, NPSHr has been predicted; the reliability of the results has been verified by comparing with the experimental data. At the same time, this practice can provide guidance for the optimal design of double-suction pump.

  14. Automated detection of kinks from blood vessels for optic cup segmentation in retinal images

    Science.gov (United States)

    Wong, D. W. K.; Liu, J.; Lim, J. H.; Li, H.; Wong, T. Y.

    2009-02-01

    The accurate localization of the optic cup in retinal images is important to assess the cup to disc ratio (CDR) for glaucoma screening and management. Glaucoma is physiologically assessed by the increased excavation of the optic cup within the optic nerve head, also known as the optic disc. The CDR is thus an important indicator of risk and severity of glaucoma. In this paper, we propose a method of determining the cup boundary using non-stereographic retinal images by the automatic detection of a morphological feature within the optic disc known as kinks. Kinks are defined as the bendings of small vessels as they traverse from the disc to the cup, providing physiological validation for the cup boundary. To detect kinks, localized patches are first generated from a preliminary cup boundary obtained via level set. Features obtained using edge detection and wavelet transform are combined using a statistical approach rule to identify likely vessel edges. The kinks are then obtained automatically by analyzing the detected vessel edges for angular changes, and these kinks are subsequently used to obtain the cup boundary. A set of retinal images from the Singapore Eye Research Institute was obtained to assess the performance of the method, with each image being clinically graded for the CDR. From experiments, when kinks were used, the error on the CDR was reduced to less than 0.1 CDR units relative to the clinical CDR, which is within the intra-observer variability of 0.2 CDR units.

  15. Seepage Study for Suction Installation of Bucket Foundation in Different Soil Combinations

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna; Ibsen, Lars Bo; Clausen, Johan Christian

    2016-01-01

    Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force and addit......Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force...... around the bucket skirt. The exceedance of critical suction might lead to installation failure due to formation of piping channels, which break the hydraulic seal between the skirt and soil. The excess pore pressure arising due to applied suction changes the effective stress, hence the penetration...

  16. 21 CFR 884.5400 - Menstrual cup.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and... OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5400 Menstrual cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  17. A Procedure for Classification of Cup-Anemometers

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels; Paulsen, Uwe Schmidt

    1997-01-01

    The paper proposes a classification procedure for cup-anemometers based on similar principles as for power converters. A range of operational parameters are established within which the response of the cup-anemometer is evaluated. The characteristics of real cup-anemometers are fitted...... to a realistic 3D cup-anemometer model. Afterwards, the model is used to calculate the response under the range of operational conditions which are set up for the classification. Responses are compared to the normal linear calibration relationship, derived from Wind tunnel calibrations. Results of the 3D cup...

  18. Feeding kinematics, suction, and hydraulic jetting performance of harbor seals (Phoca vitulina.

    Directory of Open Access Journals (Sweden)

    Christopher D Marshall

    Full Text Available The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01 than biting feeding events (0.18±0.08 s. Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land. Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001 and gape angle (12.9±2.02°, pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm and gape angle (28.8±1.80°; P<0.001 and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their

  19. 21 CFR 872.6290 - Prophylaxis cup.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing...

  20. Fourier analysis of the aerodynamic behavior of cup anemometers

    International Nuclear Information System (INIS)

    Pindado, Santiago; Pérez, Imanol; Aguado, Maite

    2013-01-01

    The calibration results (the transfer function) of an anemometer equipped with several cup rotors were analyzed and correlated with the aerodynamic forces measured on the isolated cups in a wind tunnel. The correlation was based on a Fourier analysis of the normal-to-the-cup aerodynamic force. Three different cup shapes were studied: typical conical cups, elliptical cups and porous cups (conical-truncated shape). Results indicated a good correlation between the anemometer factor, K, and the ratio between the first two coefficients in the Fourier series decomposition of the normal-to-the-cup aerodynamic force. (paper)

  1. Vacuum delivery at The Maternity Hospital Kuala Lumpur: a comparison of metal and silicone cups.

    Science.gov (United States)

    Lee, H Y; Subramaniam, N; Nordin, M M

    1996-02-01

    To compare the advantages and disadvantages of the New Bird metal cups and silicone cups in terms of maternal and foetal outcome. To study the adverse effects and factors associated with failed vacuum deliveries. A prospective randomised study of all vacuum deliveries from 1 December 1991 to 31 April 1992. The Hanshin electrical vacuum pump was used. A large obstetric unit-The Maternity Hospital Kuala Lumpur (MHKL). Seventy-two consecutive patients where vacuum deliveries were indicated. Forty had metal and 32 had silicone cups. Another 7 vacuum deliveries using the manual vacuum pump were excluded. Success rate of vaginal delivery, birth canal injuries, post-partum haemorrhage, duration of hospital stay, Apgar score, foetal injuries (scalp-ecchymosis, haematomas) neonatal jaundice, the rate of special care nursery (SCN) admission and neonatal mortality rate. Failure to deliver with silicone cups alone was 21.9% compared to 10% for metal cups alone. Material morbidities and serious foetal scalp injuries were almost the same in both cups. However, minor foetal scalp injuries were significantly lower with silicone cups. Maternal height and baby's weight had no independent predictive values for successful vacuum delivery. When the foetal head was palpable per abdomen, the failure rate was 54.5% compared to 8.2% when it was not. Failed vacuum deliveries were associated with increased maternal and foetal morbidities. Silicone cups and metal cups can be equally dangerous to the baby. Although our sample size was small, we recommend that vacuum delivery be avoided if the foetal head is palpable per abdomen.

  2. Installation process of suction anchors in Gulf of Guinea clay : Centrifuge modelling

    OpenAIRE

    THOREL, Luc; GARNIER, Jacques; RAULT, Gérard; DENDANI, Hédi; COLLIAT, JL

    2010-01-01

    The preparation process of a deepwater Gulf of Guinea clay for modelling of 24 m long suction anchors at a scale of 1/100 in the LCPC centrifuge, the clay characteristics and the installation phase (self-weight and suction) are presented. Two types of caissons have been tested in each tub : one with stiffeners and the other without stiffener. The embedment ratio is close to the suction caisson's slenderness of 3. An analysis of the forces of suction and soil friction shows, as expected, hi...

  3. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding...... soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients...... for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been...

  4. Wet cupping therapy restores sympathovagal imbalances in cardiac rhythm.

    Science.gov (United States)

    Arslan, Müzeyyen; Yeşilçam, Nesibe; Aydin, Duygu; Yüksel, Ramazan; Dane, Senol

    2014-04-01

    A recent study showed that cupping had therapeutic effects in rats with myocardial infarction and cardiac arrhythmias. The current studyaimed to investigate the possible useful effects of cupping therapy on cardiac rhythm in terms of heart rate variability (HRV). Forty healthy participants were included. Classic wet cupping therapy was applied on five points of the back. Recording electrocardiography (to determine HRV) was applied 1 hour before and 1 hour after cupping therapy. All HRV parameters increased after cupping therapy compared with before cupping therapy in healthy persons. These results indicate for the first time in humans that cupping might be cardioprotective. In this study, cupping therapy restored sympathovagal imbalances by stimulating the peripheral nervous system.

  5. Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement.

    Science.gov (United States)

    Liu, Feng; Williams, Sophie; Jin, Zhongmin; Fisher, John

    2013-11-01

    Head contact on the rim of the cup causes stress concentration and consequently increased wear. The head contact on the rim of the cup may in addition cause an offset load and torque on the cup. The head-rim contact resulting from microseparation or subluxation has been investigated. An analytical model has been developed to calculate the offset loading and resultant torque on the cup as a function of the translational displacement of the head under simplified loading condition of the hip joint at heel strike during a walking cycle. The magnitude of the torque on the cup was found to increase with the increasing translational displacement, larger diameter heads, eccentric cups, and the coefficient of friction of the contact. The effects of cup inclination, cup rim radius, and cup coverage angle on the magnitude of the torque were found to be relatively small with a maximum variation in the torque magnitude being lower than 20%. This study has shown an increased torque due to the head loading on the rim of the cup, and this may contribute to the incidence of cup loosening. Particularly, metal-on-metal hip joints with larger head diameters may produce the highest offset loading torque.

  6. The impact of soil suction variation on earthquake intensity indices

    Directory of Open Access Journals (Sweden)

    Biglari Mahnoosh

    2016-01-01

    Full Text Available Soil properties can completely change the ground motion characteristics as they travel from the bedrock to the surface because, soil as a low-pass filter, may amplify or deamplify seismic motions in some frequencies on the wave travelling path. Recent studies about the advanced unsaturated soil mechanics clearly shows that dynamic properties of soils, including small-strain shear modulus (Gmax, shear modulus reduction (G/Gmax, and damping ratio (D curves are affected by changes in the soil suction level. The current study present nonlinear time-dependent analysis of three different unsaturated soils available in the literature with different ranges of nonlinear behaviour that earlier have been studied on unsaturated dynamic models. Since, the earthquake intensity parameters can be used to describe the damage potential of an earthquake, the focus of this paper is to evaluate the impact of the suction variation on the engineering ground motion parameters, including peak values of strong motion, Vmax/Amax, root-mean-square acceleration, Arias intensity, characteristic intensity, cumulative absolute velocity, acceleration spectrum intensity, effective design acceleration, A95 parameter and predominant period separately under the near-field and the far-field seismicity categories.

  7. An updated review of the efficacy of cupping therapy.

    Science.gov (United States)

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted.

  8. An Updated Review of the Efficacy of Cupping Therapy

    Science.gov (United States)

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Background Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Method Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. Results 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Conclusions Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted. PMID:22389674

  9. An updated review of the efficacy of cupping therapy.

    Directory of Open Access Journals (Sweden)

    Huijuan Cao

    Full Text Available BACKGROUND: Since 1950, traditional Chinese medicine (TCM cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs to evaluate the therapeutic effect of cupping therapy. METHOD: Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. RESULTS: 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy, cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. CONCLUSIONS: Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted.

  10. Sound analysis of a cup drum

    International Nuclear Information System (INIS)

    Kim, Kun ho

    2012-01-01

    The International Young Physicists’ Tournament (IYPT) is a worldwide tournament that evaluates a high-school student's ability to solve various physics conundrums that have not been fully resolved in the past. The research presented here is my solution to the cup drum problem. The physics behind a cup drum has never been explored or modelled. A cup drum is a musical instrument that can generate different frequencies and amplitudes depending on the location of a cup held upside-down over, on or under a water surface. The tapping sound of a cup drum can be divided into two components: standing waves and plate vibration. By individually researching the nature of these two sounds, I arrived at conclusions that could accurately predict the frequencies in most cases. When the drum is very close to the surface, qualitative explanations are given. In addition, I examined the trend of the tapping sound amplitude at various distances and qualitatively explained the experimental results. (paper)

  11. Migration of the Duraloc cup after 5 years.

    Science.gov (United States)

    Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter; Windhager, Reinhard

    2008-12-01

    The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).

  12. [Progress of researches on the mechanism of cupping therapy].

    Science.gov (United States)

    Cui, Shuai; Cui, Jin

    2012-12-01

    Cupping therapy of Chinese medicine is able to relieve a variety of diseases or clinical conditions, which results from the comprehensive effects of multiple types of stimulation exerted onto the regional acupoint areas. Among the stimuli, the negative pressure from cupping is one of the main factors inducing therapeutic effects. In the present paper, the authors review development of researches on the underlying mechanism of therapeutic effects of cupping-negative pressure from 1) the factor of intra-cup negative pressure; 2) influence of intra-cup negative pressure on cup-blackspot formation; 3) influence of cupping on regional blood vessels and blood flow; 4) effect of cupping on regional ultrastructure of the capillary in the raw-surface tissue; 5) effect of cupping-negative pressure on regional endothelial cells; and 6) biological effects of negative pressure drainage. Generally, cupping induced negative pressure can dilate local blood vessels to improve microcirculation, promote capillary endothelial cells repair, accelerate granulation and angiogenesis, etc., in the regional tissues, normalizing the patients' functional state at last.

  13. Proteomic effects of wet cupping (Al-hijamah).

    Science.gov (United States)

    Almaiman, Amer A

    2018-01-01

    Wet cupping (Al-hijamah) is a therapeutic technique practiced worldwide as a part of the Unani system of medicine. It involves bloodletting from acupoints on a patient's skin to produce a therapeutic outcome. A thorough review of research articles on wet cupping with relevance to proteomics field that are indexed by Google Scholar, PubMed, and/or Science Direct databases was performed. Eight original research articles were summarized in this paper. Overall, wet cupping did not have a significant effect on C-reactive protein, Hsp-27, sister chromatid exchanges, and cell replication index. In contrast, wet cupping was found to produce higher oxygen saturation, eliminate lactate from subcutaneous tissues, remove blood containing higher levels of malondialdehyde and nitric oxide, and produce higher activity of myeloperoxidase. The proteomic effects of wet cupping therapy have not been adequately investigated. Thus, future studies on wet cupping that use systemic and sound protocols to avoid bias should be conducted.

  14. Proteomic effects of wet cupping (Al-hijamah

    Directory of Open Access Journals (Sweden)

    Amer A. Almaiman

    2018-01-01

    Full Text Available Wet cupping (Al-hijamah is a therapeutic technique practiced worldwide as a part of the Unani system of medicine. It involves bloodletting from acupoints on a patient’s skin to produce a therapeutic outcome. A thorough review of research articles on wet cupping with relevance to proteomics field that are indexed by Google Scholar, PubMed, and/or Science Direct databases was performed. Eight original research articles were summarized in this paper. Overall, wet cupping did not have a significant effect on C-reactive protein, Hsp-27, sister chromatid exchanges, and cell replication index. In contrast, wet cupping was found to produce higher oxygen saturation, eliminate lactate from subcutaneous tissues, remove blood containing higher levels of malondialdehyde and nitric oxide, and produce higher activity of myeloperoxidase. The proteomic effects of wet cupping therapy have not been adequately investigated. Thus, future studies on wet cupping that use systemic and sound protocols to avoid bias should be conducted.

  15. Effects of shallow and deep endotracheal tube suctioning on cardiovascular indices in patients in intensive care units.

    Science.gov (United States)

    Irajpour, Alireza; Abbasinia, Mohammad; Hoseini, Abbas; Kashefi, Parviz

    2014-07-01

    Clearing the endotracheal tube through suctioning should be done to promote oxygenation. Depth of suctioning is one of the variables in this regard. In shallow suctioning method, the catheter passes to the tip of the endotracheal tube, and in deep suctioning method, it passes beyond the tip into the trachea or brunches. This study aimed to evaluate the effect of shallow and deep suctioning methods on cardiovascular indices in patients hospitalized in the intensive care units (ICUs). In this clinical trial, 74 patients were selected among those who had undergone mechanical ventilation in the ICU of Al-Zahra Hospital, Isfahan, Iran using convenience sampling method. The subjects were randomly allocated to shallow and deep suctioning groups. Heart rate (HR) and blood pressure (BP) were measured immediately before and 1, 2, and 3 min after each suctioning. Number of times of suctioning was also noted in both the groups. Data were analyzed using repeated measures analysis of variance (ANOVA), Chi-square and independent t-tests. HR and BP were significantly increased after suctioning in both the groups (P 0.05). The suctioning count was significantly higher in the shallow suctioning group than in the deep suctioning group. Shallow and deep suctioning were similar in their effects on HR and BP, but shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, in order to prevent complications, nurses are recommended to perform the endotracheal tube suctioning by the deep method.

  16. Dynamic stiffness of suction caissons - vertical vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    The dynamic response of offshore wind turbines are affected by the properties of the foundation and the subsoil. The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three-dimensional coupled Boundary Element/Finite Element model. Comparisons are made with known analytical and numerical solutions in order to evaluate the static and dynamic behaviour of the Boundary Element/Finite Element model. The vertical frequency dependent stiffness has been determined for different combinations of the skirt length, Poisson's ratio and the ratio between soil stiffness and skirt stiffness. Finally the dynamic behaviour at high frequencies is investigated. (au)

  17. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. History of cupping (Hijama): a narrative review of literature.

    Science.gov (United States)

    Qureshi, Naseem Akhtar; Ali, Gazzaffi Ibrahim; Abushanab, Tamer Shaban; El-Olemy, Ahmed Tawfik; Alqaed, Meshari Saleh; El-Subai, Ibrahim S; Al-Bedah, Abdullah M N

    2017-05-01

    Cupping (Hijama in Arabic) is an ancient, holistic method for the treatment of a variety of diseases. Though the exact origin of cupping therapy is a matter of controversy, its use has been documented in early Egyptian and Chinese medical practices. Diverse human civilizations have contributed to the historical development and continuation of cupping therapy. This narrative review describes the history of cupping, historical definitions, cupping instruments and uses of cupping therapy. Electronic searches of relevant databases (PubMed, Google Scholar and OvidSP) were conducted using keywords and Boolean operators. Manual searches and references of published articles and books were also conducted. A number of articles (N = 625) were retained for extensive review, and finally 83 articles were included in this paper. The historical descriptions of cupping therapy were found in ancient human civilizations of the Eastern and Western world. There were inconsistent data concerning the origin of cupping, definitions, instruments, procedures, definite advancements and research in Hijama over centuries. Cupping therapy fell out of favor in 17th and mid-18th centuries but recovered popularity in modern medicine. Currently, cupping therapy is used for health promotion, prophylaxis and treatment of a variety of diseases around the world. Cupping therapy with a good safety profile has a checkered history and is a well-recognized traditional method for managing medical conditions. Currently, the scope of cupping therapy is expanding, and a growing body of research is providing additional evidence-based data for the further advancement of cupping therapy in the treatment of a variety of diseases.

  19. Lamp with a truncated reflector cup

    Science.gov (United States)

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  20. Spinal cord electrophysiology II: extracellular suction electrode fabrication.

    Science.gov (United States)

    Garudadri, Suresh; Gallarda, Benjamin; Pfaff, Samuel; Alaynick, William

    2011-02-20

    Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively.

  1. Effect of suction on the mechanical characteristics of uniformly compacted rammed earth

    Science.gov (United States)

    El Hajjar, A.; Chauhan, P.; Prime, N.; Plé, O.

    2018-04-01

    Rammed earth, in the current environmental situation, is an alternative construction technique which can help in reducing energy and raw material consumption owing to its “sustainable” characteristics. To fully understand its behavior and properties, recent scientific investigations consider it as a compacted unsaturated material with suction as its one of the main sources of strength. Eathern constructions face, over their lifetime, variations in the suction state which have a significant impact on their mechanical characteristics. In the present contribution, unconfined compression tests are performed, with and without unload-reload cycles, on homogeneously compacted samples subjected to various suction conditions. This study shows that both the unconfined compressive strength and Young modulus reduce with the reduction of suction states. Suction also seems to influence the amount of plastic strains and damage phenomenon. Indeed, the soils analyzed are slightly active and shows both plasticity behavior and damage phenomenon.

  2. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.

    Science.gov (United States)

    Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A

    2014-10-01

    other preoperative parameters in this series. The benefit of cup medialization is variable and depends on the individual anatomy. Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.

  3. Wet-cupping removes oxidants and decreases oxidative stress.

    Science.gov (United States)

    Tagil, Suleyman Murat; Celik, Huseyin Tugrul; Ciftci, Sefa; Kazanci, Fatmanur Hacievliyagil; Arslan, Muzeyyen; Erdamar, Nazan; Kesik, Yunus; Erdamar, Husamettin; Dane, Senol

    2014-12-01

    Wet-cupping therapy is one of the oldest known medical techniques. Although it is widely used in various conditions such as acute\\chronic inflammation, infectious diseases, and immune system disorders, its mechanism of action is not fully known. In this study, we investigated the oxidative status as the first step to elucidate possible mechanisms of action of wet cupping. Wet cupping therapy is implemented to 31 healthy volunteers. Venous blood samples and Wet cupping blood samples were taken concurrently. Serum nitricoxide, malondialdehyde levels and activity of superoxide dismutase and myeloperoxidase were measured spectrophotometrically. Wet cupping blood had higher activity of myeloperoxidase, lower activity of superoxide dismutase, higher levels of malondialdehyde and nitricoxide compared to the venous blood. Wet cupping removes oxidants and decreases oxidative stress. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Numerical Buckling Analysis of Large Suction Caissons for Wind Turbines on Deep Water

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming cost-effective technology also referred to as bucket foundations. During operation, the monopod bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation...... the suction caisson is loaded by external pressure (internal suction) due to evacuation of water inside the bucket and vertical forces due to gravity. The risk of structural buckling during installation of large-diameter suction caissons is addressed using numerical methods. Initial imperfect geometries...

  5. Vortex lift augmentation by suction on a 60 deg swept Gothic wing

    Science.gov (United States)

    Taylor, A. H.; Jackson, L. R.; Huffman, J. K.

    1982-01-01

    An experimental investigation was conducted in the Langley high-speed 7- by 10-foot wind tunnel to determine the aerodynamic performance of suction applied near the wing tips above the trailing edge of a 60 deg swept Gothic wing. Moveable suction inlets were symmetrically mounted in the proximity of the trailing edge, and the amount of suction was varied to maximize wing lift. Tests were conducted at Mach 0.15, 0.30, and 0.45, and the angle of attack was varied from -4 to 50 deg. The suction augmentation increases the lift coefficient over the entire range of angle of attack. The lift improvement exceeds the unaugmented wing lift by over 20%. Moreover, the augmented lift exceeds the lift predicted by vortex lattice theory to 30 deg angle of attack. Suction augmentation is postulated to strengthen the vortex system by increasing its velocity and making it more concentrated. This causes the vortex breakdown to be delayed to a higher angle of attack

  6. Evaluation of Karl Storz CMAC TipTM Device Versus Traditional Airway Suction in a Cadaver Model

    Directory of Open Access Journals (Sweden)

    Demis N. Lipe

    2014-07-01

    Full Text Available Introduction: We compared the efficacy of Karl Storz CMAC TipTM with inline suction to CMAC with traditional suction device in cadaveric models simulating difficult airways, using media mimicking pulmonary edema and vomit. Methods: This was a prospective, cohort study in which we invited emergency medicine faculty and residents to participate. Each participant intubated 2 cadavers (one with simulated pulmonary edema and one with simulated vomit, using CMAC with inline suction and CMAC with traditional suction. Thirty emergency medicine providers performed 4 total intubations each in a crossover trial comparing the CMAC with inline suction and CMAC with traditional suction. Two intubations were performed with simulated vomit and two with simulated pulmonary edema. The primary outcome was time to successful intubation; and the secondary outcome was proportion of successful intubation. Results: The median time to successful intubation using the CMAC with inline suction versus traditional suction in the pulmonary edema group was 29s and 30s respectively (p=0.54. In the vomit simulation, the median time to successful intubation was 40s using the CMAC with inline suction and 41s using the CMAC with traditional suction (p=0.70. There were no significant differences in time to successful intubation between the 2 devices. Similarly, the proportions of successful intubation were also not statistically significant between the 2 devices. The proportions of successful intubations using the inline suction were 96.7% and 73.3%, for the pulmonary edema and vomit groups, respectively. Additionally using the handheld suction device, the proportions for the pulmonary edema and vomit group were 100% and 66.7%, respectively. Conclusion: CMAC with inline suction was no different than CMAC with traditional suction and was associated with no statistically significant differences in median time to intubation or proportion of successful intubations. [West J Emerg Med

  7. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Science.gov (United States)

    Motani, Ryosuke; Ji, Cheng; Tomita, Taketeru; Kelley, Neil; Maxwell, Erin; Jiang, Da-yong; Sander, Paul Martin

    2013-01-01

    Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the establishment of modern

  8. Effect of inflow discharges on the development of matric suction and volumetric water content for dike during overtopping tests

    Science.gov (United States)

    Hassan, Marwan A.; Ismail, Mohd A. M.

    2017-10-01

    The point of this review is to depict the impact of various inflow discharge rate releases on the instruments of matric suction and volumetric water content during an experimental test of spatial overtopping failure at school of civil engineering in universiti Sains of Malaysia. A dry sand dike was conducted inside small flume channel with twelve sensors of tensiometer and Time-Domain Reflectometer (TDR). Instruments are installed in the soil at different locations in downstream and upstream slopes of the dike for measuring the response of matric suction and volumetric water content, respectively. Two values of inflow discharge rates of 30 and 40 L/min are utilized as a part of these experiments to simulate the effectiveness of water reservoirs in erosion mechanism. The outcomes demonstrate that the matric suction and volumetric water content are decreased and increased, respectively for both inflow discharges. The higher inflow discharges accelerate the saturation of dike soil and the erosion process faster than that for the lower inflow discharges.

  9. Morphology, Kinematics, and Dynamics: The Mechanics of Suction Feeding in Fishes.

    Science.gov (United States)

    Day, Steven W; Higham, Timothy E; Holzman, Roi; Van Wassenbergh, Sam

    2015-07-01

    Suction feeding is pervasive among aquatic vertebrates, and our understanding of the functional morphology and biomechanics of suction feeding has recently been advanced by combining experimental and modeling approaches. Key advances include the visualization of the patterns of flow in front of the mouth of a feeding fish, the measurement of pressure inside their mouth cavity, and the employment of analytical and computational models. Here, we review the key components of the morphology and kinematics of the suction-feeding system of anatomically generalized, adult ray-finned fishes, followed by an overview of the hydrodynamics involved. In the suction-feeding apparatus, a strong mechanistic link among morphology, kinematics, and the capture of prey is manifested through the hydrodynamic interactions between the suction flows and solid surfaces (the mouth cavity and the prey). It is therefore a powerful experimental system in which the ecology and evolution of the capture of prey can be studied based on first principals. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  10. Impedance of flexible suction caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten; Andersen, Lars; Ibsen, Lars Bo

    2007-01-01

    The dynamic response of offshore wind turbines is affected by the properties of the foundation and the subsoil. The aim of this paper is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigations include evaluation of the vertical and cou...

  11. Earliest directly-dated human skull-cups.

    Directory of Open Access Journals (Sweden)

    Silvia M Bello

    Full Text Available BACKGROUND: The use of human braincases as drinking cups and containers has extensive historic and ethnographic documentation, but archaeological examples are extremely rare. In the Upper Palaeolithic of western Europe, cut-marked and broken human bones are widespread in the Magdalenian (∼15 to 12,000 years BP and skull-cup preparation is an element of this tradition. PRINCIPAL FINDINGS: Here we describe the post-mortem processing of human heads at the Upper Palaeolithic site of Gough's Cave (Somerset, England and identify a range of modifications associated with the production of skull-cups. New analyses of human remains from Gough's Cave demonstrate the skilled post-mortem manipulation of human bodies. Results of the research suggest the processing of cadavers for the consumption of body tissues (bone marrow, accompanied by meticulous shaping of cranial vaults. The distribution of cut-marks and percussion features indicates that the skulls were scrupulously 'cleaned' of any soft tissues, and subsequently modified by controlled removal of the facial region and breakage of the cranial base along a sub-horizontal plane. The vaults were also 'retouched', possibly to make the broken edges more regular. This manipulation suggests the shaping of skulls to produce skull-cups. CONCLUSIONS: Three skull-cups have been identified amongst the human bones from Gough's Cave. New ultrafiltered radiocarbon determinations provide direct dates of about 14,700 cal BP, making these the oldest directly dated skull-cups and the only examples known from the British Isles.

  12. Phylogeny of diving beetles reveals a coevolutionary arms race between the sexes.

    Directory of Open Access Journals (Sweden)

    Johannes Bergsten

    Full Text Available BACKGROUND: Darwin illustrated his sexual selection theory with male and female morphology of diving beetles, but maintained a cooperative view of their interaction. Present theory suggests that instead sexual conflict should be a widespread evolutionary force driving both intersexual coevolutionary arms races and speciation. METHODOLOGY/PRINCIPAL FINDINGS: We combined Bayesian phylogenetics, complete taxon sampling and a multi-gene approach to test the arms race scenario on a robust diving beetle phylogeny. As predicted, suction cups in males and modified dorsal surfaces in females showed a pronounced coevolutionary pattern. The female dorsal modifications impair the attachment ability of male suction cups, but each antagonistic novelty in females corresponds to counter-differentiation of suction cups in males. CONCLUSIONS: A recently diverged sibling species pair in Japan is possibly one consequence of this arms race and we suggest that future studies on hypoxia might reveal the key to the extraordinary selection for female counter-adaptations in diving beetles.

  13. Turbulent flow with suction in smooth and rough pipes

    International Nuclear Information System (INIS)

    Verdier, Andre.

    1977-11-01

    It concerns an experimental study of turbulent flow inside a pipe with rough and porous wall and suction applied through it. The first part recall the basic knowledge concerning the turbulent flow with roughness. In second part statistical equations of fluid wall stress are written in the case of a permeable rough wall, in order to underline the respective role played by viscosity and pressure terms. In the third part the dynamic equilibrium of the flow is experimentally undertaken in the smooth and rough range with and without wall suction. Some empirical formulae are proposed for the mean velocity profiles in the inertial range and for friction velocity with suction. In the case of the sand roughness used, it does not seem that critical Reynolds number of transition from smooth to rough range is varied [fr

  14. Paradoxical, Cupping-Induced Localized Psoriasis: A Koebner Phenomenon.

    Science.gov (United States)

    Vender, Reid; Vender, Ronald

    2015-01-01

    Cupping therapy is a traditional Chinese medicine used to heal psoriasis. The Koebner phenomenon is the occurrence of psoriatic lesions at the site of cutaneous injury. To describe the first case of biopsy-proven cupping-induced localized psoriasis, an example of the Koebner phenomenon. The histopathology of the lesions is described. A brief review of the literature regarding cupping therapy and its efficacy are discussed. A 45-year-old Asian male presented himself to the dermatology clinic for further treatment of his psoriasis. Four unusually circular plaques on the lower back were discovered. Pathologic diagnosis revealed an early lesion of psoriasis. on further inquiry, the patient admitted to undergoing a recent "cupping" procedure in an attempt to cure his condition. The efficacy of cupping therapy is controversial, and psoriatic patients may develop localized psoriasis through koebnerization as a result of cupping therapy rather than achieve desirable therapeutic benefits. © 2014 Canadian Dermatology Association.

  15. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Directory of Open Access Journals (Sweden)

    Ryosuke Motani

    Full Text Available Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the

  16. A Technique for Controlling Matric Suction on Filter Papers . GroWth ...

    African Journals Online (AJOL)

    'Abstract. Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers ...

  17. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    International Nuclear Information System (INIS)

    Ye, W.M.; Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G.; Cui, Y.J.

    2012-01-01

    Highlights: ► Heating induced volumetric change of GMZ01 bentonite depends on suction. ► Suction has significant influence on compressibility. ► Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 °C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 × 10 −4 °C −1 ; (2) with increasing suction, the elastic compressibility κ and the plastic compressibility λ(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility λ(s) slightly decreases and the yield surface tends to shrink.

  18. Factors influencing initial cup stability in total hip arthroplasty.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad

    2014-12-01

    One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. A Technique for Controlling Matric Suction on Filter Papers Used in ...

    African Journals Online (AJOL)

    Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers wetted to ...

  20. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Science.gov (United States)

    2010-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  1. Recent advances in uranium exploration with electronic alpha cups

    International Nuclear Information System (INIS)

    Warren, R.K.

    1977-01-01

    Data from a new radon measuring device, based on electronic alpha cups are compared with data from the nonelectronic, plastic alpha cups commonly used in exploring for uranium. A burial time of three days appears to be adequate for the electronic alpha cups to collect exploration data equivalent to those from plastic sensing devices. The advantages of the electronic cups are short time of burial and instant readout in the field; the major disadvantages is the capital expenditure required for the instruments. It is possible the cups may be useful for copper exploration too. 5 refs

  2. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  3. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    Science.gov (United States)

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Analisis Perubahan Nilai Suction Akibat Hujan Terhadap Kestabilan Lereng

    OpenAIRE

    Martini, Martini

    2009-01-01

    Infiltration of rainfall into slope will have an effect on to condition of slope hydrology and more specifically to characteristic of slope soils, for example pore water pressure value, level of saturation, weight contents of soil, shear strength of soil. Pore water pressure value at dry soil condition or wet condition called as with pore water pressure value negatife or value suction. This suction value will tend to declines and in the end becomes equal to zero or bigger than 0 ( positive po...

  5. A critical comparison of ten disposable cup LCAs

    Energy Technology Data Exchange (ETDEWEB)

    Harst, Eugenie van der, E-mail: eugenie.vanderharst@wur.nl [Environmental Systems Analysis Group, Wageningen University, P.O. Box 47, NL-6700 AA Wageningen (Netherlands); Potting, José, E-mail: jose.potting@wur.nl [Environmental Systems Analysis Group, Wageningen University, P.O. Box 47, NL-6700 AA Wageningen (Netherlands); Environmental Strategies Research (fms), KTH Royal Institute of Technology, SE-110 44 Stockholm (Sweden)

    2013-11-15

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) also shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches.

  6. A critical comparison of ten disposable cup LCAs

    International Nuclear Information System (INIS)

    Harst, Eugenie van der; Potting, José

    2013-01-01

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) also shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches

  7. Comparative study of the characteristics of some suction devices for gas sampling applications

    International Nuclear Information System (INIS)

    Donguy, R.; Drouet, J.

    1959-06-01

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc

  8. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Ye, W.M., E-mail: ye_tju@tongji.edu.cn [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); United Research Center for Urban Environment and Sustainable Development, The Ministry of Education, Shanghai 200092 (China); Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Cui, Y.J. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Ecole des Ponts ParisTech, UR Navier/CERMES 77455 (France)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Heating induced volumetric change of GMZ01 bentonite depends on suction. Black-Right-Pointing-Pointer Suction has significant influence on compressibility. Black-Right-Pointing-Pointer Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 Degree-Sign C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 Multiplication-Sign 10{sup -4} Degree-Sign C{sup -1}; (2) with increasing suction, the elastic compressibility {kappa} and the plastic compressibility {lambda}(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility {lambda}(s) slightly decreases and the yield surface tends to shrink.

  9. Development of a classification system for cup anemometers - CLASSCUP

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    2003-01-01

    the objectives to quantify the errors associated with the use of cup anemometers, and to determine the requirements for an optimum design of a cup anemometer, and to develop a classification system forquantification of systematic errors of cup anemometers. The present report describes this proposed...... classification system. A classification method for cup anemometers has been developed, which proposes general external operational ranges to be used. Anormal category range connected to ideal sites of the IEC power performance standard was made, and another extended category range for complex terrain...... was proposed. General classification indices were proposed for all types of cup anemometers. As a resultof the classification, the cup anemometer will be assigned to a certain class: 0.5, 1, 2, 3 or 5 with corresponding intrinsic errors (%) as a vector instrument (3D) or as a horizontal instrument (2D...

  10. Suction of MHD boundary layer flows

    International Nuclear Information System (INIS)

    Rao, B.N.

    1985-01-01

    The boundary layer growth with tensor electrical conductivity and the transpiration number has been examined using local nonsimilarity solutions method. It is found that suction will cause the increase in wall shearing stress and decrease in thicknesses of the boundary layer. (Auth.)

  11. Accumulation of radon in the underground detector cups

    International Nuclear Information System (INIS)

    Qiu Yuanhuo.

    1985-01-01

    Theoretical calculations based on the radon migration mechanism (i. e. diffusion, convection and atmospheric pumping etc) show that the balance of radon concentration in underground detector cups buried and in surrounding soil gas requires about 0.7-10 hours. However, the equilibrium of radon with its daughter products in the cups needs about 4 hours. Therefore, it is considered that 4.5-12 hours are needed for these two processes. It takes 3-4 days for Tn to reach radioactive equilibrium with its short-lived daughter products. When thorium concentration is higher than background exposure time of the detector cups should be over 3-4 days. Using buried detector cups, field experiments give correlative results compared with those of theoretical calculations. The study is oriented both for optimizing the burial time of the detector cup and interpretation of radon anomalies detected

  12. Distance constant of the Risø cup anemometer

    DEFF Research Database (Denmark)

    Kristensen, L.; Frost Hansen, O.

    2002-01-01

    The theory for cup-anemometer dynamics is presented in some detail and two methods of obtaining the distance constant lo are discussed. The first method is based on wind tunnel measurements: with a constant wind speed the cup anemometer is released from alocked position of the rotor...... and the increasing rotation rate recorded. It is concluded that the rapid increase in rotation rate makes the method very inaccurate. The second method consists of an analysis of turbulent, atmospheric of wind speed asmeasured by the cup anemometer and a fast-responding sonic anemometer with a spatial eddy...... resolution which is significantly better than that which can be obtained by a cup anemometer. The ratio between the measured power spectra of the horizontal windspeed by the two instruments contains the necessary information for determining the response characteristics of the cup anemometer and thereby lo...

  13. Biological characterization of two xenografts derived from human CUPs (carcinomas of unknown primary

    Directory of Open Access Journals (Sweden)

    Bernheim Alain

    2007-12-01

    Full Text Available Abstract Background Carcinomas of unknown primary site (CUP are epithelial malignancies revealed by metastatic lesions in the absence of any detectable primary tumor. Although they often adopt an aggressive clinical pattern, their basic biology remains poorly understood. Laboratory research on their biology have been hampered so far by the absence of cell lines representative of CUPs. Methods We attempted xenografts of CUP clinical specimens in immunodeficient mice and subsequent in vitro culture of transplanted malignant cells. Whenever possible, malignant xenografted or cultured cells were characterized by microsatellite genotyping, immunohistology, electron microscopy, multifish chromosome analysis and search of TP 53 gene mutations. Results Successful xenografts were achieved in 2 cases out of 4. One of them (Capi1 was lost after 3 passages whereas the other one (Capi3 has been adapted to in vitro culture and is currently available to the scientific community with reliable identification based on microsatellite genotyping. Both Capi1 and Capi3 have histological characteristics of adenocarcinomas and display intense expression of EMA, CEA and cytokeratin 7. Multifish chromosome analysis demonstrated a translocation involving chromosomes 4 and 21 in both specimens. Distinct rare missense mutations of the TP53 gene were detected in Capi1 (codon 312 and Capi3 (codon 181; the codon 181 mutation is consistent with a previously reported similar finding in a small series of CUP specimens. Finally, intense membrane expression of c-kit was recorded in Capi3. Conclusion Our data suggest that xenografted tumors can be obtained from a substantial fraction of CUP clinical specimens. The hypothesis of a preferential association of CUPs with TP 53 mutations of codon 181 deserves further investigations. The Capi3 cell line will be a useful tool for assessment of novel c-kit inhibitors.

  14. Bone remodeling around cementless tantalum cups

    NARCIS (Netherlands)

    Grillo, J. -C.; Flecher, X.; Bouvenot, J.; Argenson, J. -N.

    2008-01-01

    Purpose of the study.-Most studies have reported a significant decrease in periacetabular bone stock one year after implantation of a cementless cup. The purpose of this work was to study the bone-implant interface of the tantalum cup using plain X-rays and dual-energy X-ray absorptiometry (DEXA).

  15. The DHL EuroCup: shots on goal.

    Science.gov (United States)

    Hemp, Paul

    2003-11-01

    Deutsche Post World Net, the German postal monopoly, faced significant challenges as it began the process of integrating three businesses: Deutsche Post Euro Express, its own ground-based parcel delivery service, and two companies it had acquired-DHL, the worldwide express delivery service, and Danzas, a worldwide air and ocean freight company. The cultural differences alone were imposing. For example, DHL was a privately held, entrepreneurial company in which most managers had international experience; Deutsche Post was until recently a state-owned monopoly in which few managers had worked outside their home country. Enter EuroCup. For 20 years, DHL employees had held a soccer tournament to strengthen company culture across national boundaries. Canceled the previous year due to budget constraints, the EuroCup tournament was revived in 2003-in part to help with the postmerger integration. But did the event really help? HBR senior editor Paul Hemp attended EuroCup 2003, joining nearly 2,500 DHL employees--about 600 of them players, the rest cheerleaders and other supporters--in the small Belgian town of Lommel. He set out to answer a number of questions relevant to any company staging an ambitious off-site intended to encourage teamwork and boost morale. How does a company determine whether such a large-scale event, even one that generates goodwill, is worth the investment? Does the team building extend to those back home who don't get to attend? Can intense competition between teams begin to overshadow the spirit of cooperation that such an event is meant to engender? In short, can a soccer tournament help a company achieve its corporate goal of creating a strong common culture?

  16. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  17. ACCUWIND - Methods for classification of cup anemometers

    DEFF Research Database (Denmark)

    Dahlberg, J.-Å.; Friis Pedersen, Troels; Busche, P.

    2006-01-01

    the errors associated with the use of cup anemometers, and to develop a classification system for quantification of systematic errors of cup anemometers. This classification system has now been implementedin the IEC 61400-12-1 standard on power performance measurements in annex I and J. The classification...... of cup anemometers requires general external climatic operational ranges to be applied for the analysis of systematic errors. A Class A categoryclassification is connected to reasonably flat sites, and another Class B category is connected to complex terrain, General classification indices are the result...... developed in the CLASSCUP projectand earlier. A number of approaches including the use of two cup anemometer models, two methods of torque coefficient measurement, two angular response measurements, and inclusion and exclusion of influence of friction have been implemented in theclassification process...

  18. Pilot Study Comparing Closed Versus Open Tracheal Suctioning in Postoperative Neonates and Infants With Complex Congenital Heart Disease.

    Science.gov (United States)

    Tume, Lyvonne N; Baines, Paul B; Guerrero, Rafael; Hurley, Margaret A; Johnson, Robert; Kalantre, Atul; Ramaraj, Ram; Ritson, Paul C; Walsh, Laura; Arnold, Philip D

    2017-07-01

    To determine the hemodynamic effect of tracheal suction method in the first 36 hours after high-risk infant heart surgery on the PICU and to compare open and closed suctioning techniques. Pilot randomized crossover study. Single PICU in United Kingdom. Infants undergoing surgical palliation with Norwood Sano, modified Blalock-Taussig shunt, or pulmonary artery banding in the first 36 hours postoperatively. Infants were randomized to receive open or closed (in-line) tracheal suctioning either for their first or second study tracheal suction in the first 36 hours postoperatively. Twenty-four infants were enrolled over 18 months, 11 after modified Blalock-Taussig shunt, seven after Norwood Sano, and six after pulmonary artery banding. Thirteen patients received the open suction method first followed by the closed suction method second, and 11 patients received the closed suction method first followed by the open suction method second in the first 36 hours after their surgery. There were statistically significant larger changes in heart rate (p = 0.002), systolic blood pressure (p = 0.022), diastolic blood pressure (p = 0.009), mean blood pressure (p = 0.007), and arterial saturation (p = 0.040) using the open suction method, compared with closed suctioning, although none were clinically significant (defined as requiring any intervention). There were no clinically significant differences between closed and open tracheal suction methods; however, there were statistically significant greater changes in some hemodynamic variables with open tracheal suctioning, suggesting that closed technique may be safer in children with more precarious physiology.

  19. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Unsteady flow of an incompressible fluid in a horizontal porous medium with suction

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1988-04-01

    A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs

  1. MAXIMUM AIR SUCTION INTO HORIZONTAL OPEN ENDED CYLINDRICAL LOUVERED PIPE

    Directory of Open Access Journals (Sweden)

    SAMEER RANJAN SAHU

    2017-02-01

    Full Text Available The main approach behind the present numerical investigation is to estimate the mass flow rate of air sucked into a horizontal open-ended louvered pipe from the surrounding atmosphere. The present numerical investigation has been performed by solving the conservation equations for mass, momentum and energy along with two equation based k-ɛ model for a louvered horizontal cylindrical pipe by finite volume method. It has been found from the numerical investigation that mass suction rate of air into the pipe increases with increase in louvered opening area and the number of nozzles used. Keeping other parameters fixed, for a given mass flow rate there exists an optimum protrusion of nozzle for highest mass suction into the pipe. It was also found from the numerical investigation that increasing the pipe diameter the suction mass flow rate of air was increased.

  2. Bernoulli Suction Effect on Soap Bubble Blowing?

    Science.gov (United States)

    Davidson, John; Ryu, Sangjin

    2015-11-01

    As a model system for thin-film bubble with two gas-liquid interfaces, we experimentally investigated the pinch-off of soap bubble blowing. Using the lab-built bubble blower and high-speed videography, we have found that the scaling law exponent of soap bubble pinch-off is 2/3, which is similar to that of soap film bridge. Because air flowed through the decreasing neck of soap film tube, we studied possible Bernoulli suction effect on soap bubble pinch-off by evaluating the Reynolds number of airflow. Image processing was utilized to calculate approximate volume of growing soap film tube and the volume flow rate of the airflow, and the Reynolds number was estimated to be 800-3200. This result suggests that soap bubbling may involve the Bernoulli suction effect.

  3. Hydrodynamics of suction feeding in fish

    NARCIS (Netherlands)

    Muller, M.

    1983-01-01

    1. Suction feeding is the dominant way to obtain food in teleosts. Its high demands on structures due to the required velocities and forces leads to the expectation that a biophysical analysis will aid to reveal the adaptive significance of head and body structures related to this

  4. Genetic theory – a suggested cupping therapy mechanism of action

    OpenAIRE

    Shaban , Tamer; Ravalia , Munir

    2017-01-01

    The Cupping Therapy mechanism of action is not clear. Cupping may increase local blood circulation, and may have an immunomodulation effect. Local and systemic effects of Cupping Therapy were reported. Genetic expression is a physiological process that regulates body functions. Genetic modulation is a reported acupuncture effect. In this article, the authors suggest genetic modulation theory as one of the possible mechanisms of action of cupping therapy.

  5. Suction forces generated by passive bile bag drainage on a model of post-subdural hematoma evacuation.

    Science.gov (United States)

    Tenny, Steven O; Thorell, William E

    2018-05-05

    Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.

  6. Splash-cup plants accelerate raindrops to disperse seeds

    Science.gov (United States)

    Amador, Guillermo J.; Yamada, Yasukuni; McCurley, Matthew; Hu, David L.

    2013-01-01

    The conical flowers of splash-cup plants Chrysosplenium and Mazus catch raindrops opportunistically, exploiting the subsequent splash to disperse their seeds. In this combined experimental and theoretical study, we elucidate their mechanism for maximizing dispersal distance. We fabricate conical plant mimics using three-dimensional printing, and use high-speed video to visualize splash profiles and seed travel distance. Drop impacts that strike the cup off-centre achieve the largest dispersal distances of up to 1 m. Such distances are achieved because splash speeds are three to five times faster than incoming drop speeds, and so faster than the traditionally studied splashes occurring upon horizontal surfaces. This anomalous splash speed is because of the superposition of two components of momentum, one associated with a component of the drop's motion parallel to the splash-cup surface, and the other associated with film spreading induced by impact with the splash-cup. Our model incorporating these effects predicts the observed dispersal distance within 6–18% error. According to our experiments, the optimal cone angle for the splash-cup is 40°, a value consistent with the average of five species of splash-cup plants. This optimal angle arises from the competing effects of velocity amplification and projectile launching angle. PMID:23235266

  7. Study on the performance improvement of multiblade fans. Effects of suction cones; Tayoku fan no seino kaizen ni kansuru kenkyu. Suction cone no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kuratani, F.; Ogawa, T. [Hyogo University of Teacher Education, Hyogo (Japan); Yamamoto, S.

    1999-07-25

    In order to improve the performance of a multiblade fan, the effects of three types of suction cones of the fan casing on the fan efficiency and noise are investigated experimentally. The first type of the suction cone is the insertion type, which is inserted into the inside of the fan impeller. The second type is the extrusion type, which extrudes outside from the casing surface. The third type is the combination type of two types. The results of those three types are compared with those of the commonly used suction cone. The followings are made clear: (1) The insertion type and the extrusion type are effective in improving the efficiency and reducing noise. (2) The optimal lengths of the insertion and the extrusion exist. (3) The combination type is more effective in improving the efficiency. (4) The combination type with the skewed cutoff of the fan casing shows the best effect. (author)

  8. Clad vent set cup closure-weld-zone grinding evaluation

    International Nuclear Information System (INIS)

    Ulrich, G.B.; Woods, A.T.; Ohriner, E.K.

    1996-04-01

    Clad vent set (CVS) cups were ground in the closure-weld zone to reduce the wall-thickness variation created by the cup deep-drawing process. A significantly more uniform wall thickness would be beneficial for the CVS closure-weld operation. The goal was to reduce the average within-cup wall-thickness variation (defined as the range of wall thicknesses in the closure-weld zone) approximately 50% from the Cassini production value of 42 microm. This goal was shown to be achievable but, unfortunately, not with the existing blank and formed cup thicknesses

  9. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    OpenAIRE

    Pekkan, Kerem; Uslu, Fazıl E.; Chang, Brain; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-01-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larv...

  10. [Study on standardization of cupping technique: elucidation on the establishment of the National Standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping].

    Science.gov (United States)

    Gao, Shu-zhong; Liu, Bing

    2010-02-01

    From the aspects of basis, technique descriptions, core contents, problems and solutions, and standard thinking in standard setting process, this paper states experiences in the establishment of the national standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping, focusing on methodologies used in cupping standard setting process, the method selection and operating instructions of cupping standardization, and the characteristics of standard TCM. In addition, this paper states the scope of application, and precautions for this cupping standardization. This paper also explaines tentative ideas on the research of standardized manipulation of acupuncture and moxibustion.

  11. Effects of Lavender Inhalant on the Pain during Endotracheal Suctioning in Intensive Care Unit Patients

    Directory of Open Access Journals (Sweden)

    M. Taheri Rezgh Abadi

    2017-09-01

    Full Text Available Aims: Patients undergoing artificial ventilation require tracheal tube suction because of inability to clear their effective airways, which is usually a painful process for the patients. The aim of this study was to investigate the effect of spike lavender’s inhalant on pain during tracheal tube suctioning in ICU intubated patients. Materials & Methods: In this double-blinded randomized clinical trial, 60 intubated patients hospitalized in ICU of Shahid Modarres Hospital of Kashmar City, Iran, in 2017 were selected by available and simple sampling method, and were randomly divided into 2 control and case groups (each 30 individuals. Before the standard suctioning process, the test group patients received inhalant of 2% spike lavender for 5 minutes and the control group received inhalant of distilled water. The level of pain was recorded before and during tracheal tube suctioning. Data were analyzed by SPSS 16 software using independent T, paired T, Fisher and Mann-Whitney U tests. Findings: There was no significant difference in pain score before tracheal tube suction between 2 groups (p>0.05. However, there were significant differences between the level of pain during tracheal tube suctioning and the pain was increased in both groups, but this increase was significantly higher in the control group (p<0.001. Conclusion: Spike lavender’s inhalant is effective on pain reduction during suctioning process of ICU intubated patients.

  12. A retrospective study of the use of active suction wound drains in dogs and cats.

    Science.gov (United States)

    Bristow, P C; Halfacree, Z J; Baines, S J

    2015-05-01

    To report indications for use and complications associated with commonly used closed active suction wound drains in a large number of clinical cases. Retrospective review of medical case records (from 2004 to 2010) for dogs and cats that had a closed active suction drain placed into a wound. Only the four most common drain types were included: Mini Redovac®, Redovac®, Jackson Pratt® and Wound Evac®. Two hundred and fifty-three drains were placed in 33 cats and 195 dogs. Mini Redovac drains were used most frequently in cats (76 · 5%) and Redovac drains in dogs (54 · 3%). The infection rate for clean surgeries in dogs was 15 · 6% (unattainable in cats). Major complications occurred in four dogs; minor complications occurred in 12 drains in cats (35 · 3%), and in 74 drains in dogs (33 · 8%). There was no statistically significant association between the type of drain and complication rate for either species. Although closed active suction drains can be used with low risk of major complications, they lead to a high rate of infection in clean surgeries in dogs. It is recommended that such drains are kept in place for the shortest time possible and that strict asepsis is adhered to both during placement and management. © 2015 British Small Animal Veterinary Association.

  13. Orienteering World Cup hosted by CERN Club

    CERN Multimedia

    Katarina Anthony

    2010-01-01

    Elite runners took to the streets of Geneva for the last leg of the Orienteering World Cup, from 8-10 October. The Geneva finals were hosted by the CERN Orienteering Club and concluded months of competitions held across 5 countries.   Women's World-Cup winner, Simone Niggli (centre).  © Ilknur Colak The final events of the Orienteering World Cup took place in the Old Town of Geneva and Saint-Cergue, with runners following routes prepared by the CERN Orienteering Club. Orienteering is a sport of navigation, using only a compass, map and your sense of direction. The objective is to get to all the points on the map as quickly as possible, choosing your own paths as you run. This was the CERN club’s first successful participation in the World Cup, cementing its reputation as a fixture in the international orienteering world. Orienteering is not your typical Swiss pastime. Developed in Scandinavia, the sport has been gaining popularity internationally. “...

  14. Corner Separation Control by Boundary Layer Suction Applied to a Highly Loaded Axial Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Yangwei Liu

    2014-11-01

    Full Text Available Control of corner separation has attracted much interest due to its improvement of performance and energy utilization in turbomachinery. Numerical studies have been performed under both design and off-design flow conditions to investigate the effects of boundary layer suction (BLS on corner separation in a highly loaded compressor cascade. Two new BLS slot configurations are proposed and a total of five suction slot configurations were studied and compared. Averaged static pressure rise, exit loss coefficient, passage blockage and flow turning angle have been given and compared systematically over a range of operation incidence angles. Distributions of significant loss removal, blade loading, exit deviation and total pressure loss at 3 degree and 7 degree incidence have also been studied. Under the same suction mass flows of 0.7% of the inlet mass flows, the pitchwise suction slot on the endwall shows a better optimal performance over the whole operation incidence among single suction slots. By using of the new proposed compound slot configuration with one spanwise slot on the blade suction side and one pitchwise slot on the endwall, the maximum reduction of total pressure loss at 7 degree incidence can be 39.4%.

  15. Cup products in Hopf cyclic cohomology with coefficients in contramodules

    OpenAIRE

    Rangipour, Bahram

    2010-01-01

    We use stable anti Yetter-Drinfeld contramodules to improve the cup products in Hopf cyclic cohomology. The improvement fixes the lack of functoriality of the cup products previously defined and show that the cup products are sensitive to the coefficients.

  16. Functional morphology of the feeding apparatus, feeding constraints, and suction performance in the nurse shark Ginglymostoma cirratum.

    Science.gov (United States)

    Motta, Philip J; Hueter, Robert E; Tricas, Timothy C; Summers, Adam P; Huber, Daniel R; Lowry, Dayv; Mara, Kyle R; Matott, Michael P; Whitenack, Lisa B; Wintzer, Alpa P

    2008-09-01

    The nurse shark, Ginglymostoma cirratum, is an obligate suction feeder that preys on benthic invertebrates and fish. Its cranial morphology exhibits a suite of structural and functional modifications that facilitate this mode of prey capture. During suction-feeding, subambient pressure is generated by the ventral expansion of the hyoid apparatus and the floor of its buccopharyngeal cavity. As in suction-feeding bony fishes, the nurse shark exhibits expansive, compressive, and recovery kinematic phases that produce posterior-directed water flow through the buccopharyngeal cavity. However, there is generally neither a preparatory phase nor cranial elevation. Suction is generated by the rapid depression of the buccopharyngeal floor by the coracoarcualis, coracohyoideus, and coracobranchiales muscles. Because the hyoid arch of G. cirratum is loosely connected to the mandible, contraction of the rectus cervicis muscle group can greatly depress the floor of the buccopharyngeal cavity below the depressed mandible, resulting in large volumetric expansion. Suction pressures in the nurse shark vary greatly, but include the greatest subambient pressures reported for an aquatic-feeding vertebrate. Maximum suction pressure does not appear to be related to shark size, but is correlated with the rate of buccopharyngeal expansion. As in suction-feeding bony fishes, suction in the nurse shark is only effective within approximately 3 cm in front of the mouth. The foraging behavior of this shark is most likely constrained to ambushing or stalking due to the exponential decay of effective suction in front of the mouth. Prey capture may be facilitated by foraging within reef confines and close to the substrate, which can enhance the effective suction distance, or by foraging at night when it can more closely approach prey.

  17. Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control

    Science.gov (United States)

    Juhasz, A. J.; Smith, J. M.

    1977-01-01

    A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.

  18. Modulation method of scroll compressor based on suction gas bypass

    International Nuclear Information System (INIS)

    Wang Baolong; Han Linjun; Shi Wenxing; Li Xianting

    2012-01-01

    The air conditioners and heat pumps tend to work in much mild environments and part load situations rather than provide the rated full capacity under severe rated testing conditions. Both the capacity and inner compression ratio of the compressor should be regulated according to the working condition for higher energy efficiency and occupants’ comfort. A potential modulating technology of the scroll compressor, suction gas bypass, is investigated in this paper. The principle and operation method are illuminated and the adaptability is validated by experiments and simulations. As a conclusion, an appropriate suction gas bypass can reduce the inner compression loss of the scroll compressor under over compression conditions, enhance the system COP and also largely decrease the heating/cooling capacity of the refrigeration/heat pump system. - Highlights: ► Suction gas bypass (SGB) is an effective regulating method of scroll compressor. ► SGB reduces the inner compression loss under over compression conditions. ► SGB largely decreases the heating/cooling capacity of the refrigeration system.

  19. Modified Faraday cup

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.; O'Brien, Dennis W.

    1996-01-01

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0.degree. to 360.degree. and the waveforms are recorded by a digitizing storage oscilloscope. Two-din-tensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment.

  20. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  1. Soccer jersey sponsors and the world cup

    NARCIS (Netherlands)

    Groot, L.F.M.; Ferwerda, J.

    2014-01-01

    The market for soccer jerseys is a multibillion market dominated by Adidas, Nike and Puma. This paper investigates whether jersey sponsorship has a non-arbitrary effect on the outcomes of World Cup knockout matches. The results show that in the knockout stages of the last four World Cup tournaments,

  2. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    Science.gov (United States)

    Pekkan, Kerem; Chang, Brian; Uslu, Fazil; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-07-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larvae (2500-20,000 μm total length) are reported using time-resolved microscopic particle image velocimetry. For the larval stages studied, the maximum peak suction velocity of the inflow bolus is measured at a finite distance from the mouth tip and ranges from 1 to 8 mm/s. The average pressure gradient and the velocity profile proximal to the buccal (mouth) cavity are calculated, and two distinct trends are identified. External recirculation regions and reverse flow feeding cycles are also observed and quantified. One of the unresolved questions in fish suction feeding is the shape and dynamics of the buccal cavity during suction feeding; optical coherence tomography imaging is found to be useful for reconstructing the mouth kinematics. The projected area of the mouth cavity during the feeding cycle varies up to 160 and 22 % for the transverse and mid-sagittal planes, respectively. These findings can inspire novel hydrodynamically efficient biomedical and microfluidic devices.

  3. CUP Syndrome-Metastatic Malignancy with Unknown Primary Tumor.

    Science.gov (United States)

    Zaun, Gregor; Schuler, Martin; Herrmann, Ken; Tannapfel, Andrea

    2018-03-09

    2-4% of newly diagnosed cases of malignant disease involve cancer of unknown primary (CUP). This mixed entity is one of the 6 most common types of malignant disease in Germany. Highly refined treatment strategies can now be offered to patients with CUP. This review is based on pertinent publications retrieved by a selective search in PubMed with an emphasis on articles from the past decade. The current guidelines and recommendations of specialty societies were also considered in the evaluation. CUP most commonly manifests itself as metastases to the lymph nodes, lungs, liver, or bones. With the aid of imaging studies, including functional hybrid imaging and further medical examination, a primary tumor can be discovered in up to 40% of patients initially diagnosed with CUP. Immunohistochemistry guided by histomorphology often enables precise characterization of the lesion and can be supplemented, in selected cases, by molecular-genetic diagnostic evaluation. The most commonly detected types of primary tumor are cancers of the lung, pancreas, liver, and biliary system. For patients with local metastases, surgical resection or radiotherapy with curative intent is usually indicated, sometimes in the framework of a multimodal treatment concept. The median 2-year survival of patients with disseminated CUP is only 20%. For such patients, specific types of systemic therapy are recommended on the basis of the diagnostic characterization of the disease. Immune-modulatory antibodies can be effective, particularly in the treatment of CUP that has been characterized with biomarkers, but should still be considered experimental at present. A combination of conventional and innovative diagnostic methods enables the provision of highly refined therapeutic strategies to patients with CUP who are undergoing treatment in interdisciplinary cancer centers.

  4. Nuclear fuel element nut retainer cup

    International Nuclear Information System (INIS)

    Walton, L.A.

    1977-01-01

    A typical embodiment has an end fitting for a nuclear reactor fuel element that is joined to the control rod guide tubes by means of a nut plate assembly. The nut plate assembly has an array of nuts, each engaging the respective threaded end of the control rod guide tubes. The nuts, moreover, are retained on the plate during handling and before fuel element assembly by means of hollow cylindrical locking cups that are brazed to the plate and loosely circumscribe the individual enclosed nuts. After the nuts are threaded onto the respective guide tube ends, the locking cups are partially deformed to prevent one or more of the nuts from working loose during reactor operation. The locking cups also prevent loose or broken end fitting parts from becoming entrained in the reactor coolant

  5. New approach to the suction force at the leading edge of a profile with zero thickness

    NARCIS (Netherlands)

    Sparenberg, JA; de Jager, EM

    2004-01-01

    This paper considers the suction force at the leading edge of a profile with zero thickness in an incompressible and inviscid fluid flow. The theory is linear, and the approach to the suction force is from the innerside of the profile. It is shown that the suction force can be considered as an

  6. Pad for holding a load against a surface by suction

    International Nuclear Information System (INIS)

    Farmer, R.C.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention concerns suction pads for supporting loads. Specifically, the suction pad is part of a pair of pads located at the ends of a bridge forming a vehicle for transporting instruments for the non-destructive testing of a large vessel intended to contain a fuel assembly for a nuclear reactor immersed in a liquid metal coolant. For example, the vehicle is of the type described in the French patent application filed this day under the heading 'Vehicle for transporting instruments for testing against a wall' [fr

  7. A Zero-Gravity Cup for Drinking Beverages in Microgravity

    Science.gov (United States)

    Pettit, Donald R.; Weislogel, Mark; Concus, Paul; Finn, Robert

    2011-01-01

    To date, the method for astronauts to drink liquids in microgravity or weightless environments is to suck the liquid from a bag or pouch through a straw. A new beverage cup works in microgravity and allows astronauts to drink liquids from a cup in a manner consistent with that on Earth. The cup is capable of holding beverages with an angled channel running along the wall from the bottom to the lip. In microgravity, a beverage is placed into the cup using the galley dispenser. The angled channel acts as an open passage that contains only two sides where capillary forces move the liquid along the channel until it reaches the top lip where the forces reach an equilibrium and the flow stops. When one sips the liquid at the lip of the channel, the capillary force equilibrium is upset and more liquid flows to the lip from the reservoir at the bottom to re-establish the equilibrium. This sipping process can continue until the total liquid contents of the cup is consumed, leaving only a few residual drops about the same quantity as in a ceramic cup when it is drunk dry on Earth.

  8. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    Directory of Open Access Journals (Sweden)

    AZZEDINE NAHOUI

    2013-12-01

    Full Text Available A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has demonstrated its positive effect on the transition point and the friction coefficient. Both control procedures are compared for different lengths, speeds and angles of blowing and suction.

  9. Reliable site for suction blister induction and harvesting

    Directory of Open Access Journals (Sweden)

    Laxmisha Chandrashekar

    2005-01-01

    Full Text Available Background: Suction blister grafting is a useful modality of treatment of patients with resistant and stable vitiligo. However, there have been no detailed studies to find out the best donor site for blister formation. Methods: The study was conducted between the period of October 2004 and February 2005 in the dermatology department at a tertiary care center. Nine patients with vitiligo (focal vitiligo, 3; mucosal vitiligo, 2; acrofacial vitiligo, 2; vitiligo vulgaris, 1; and segmental vitiligo, 1 were selected for blister harvesting and grafting. The blisters were raised using the method described by Gupta et al. Results: Suction blisters were attempted to be raised at 52 sites, but only 38 blisters could be raised, 24 complete and 14 incomplete. Blisters were raised in all the three cases on the flexor aspect of the arm (100%, 15 of 17 cases (88.2% on the flexor aspect of the forearm, 4 of 5 cases (80% on the abdomen, 11 of 16 cases (68.7% on the anterolateral thigh, and less frequently over leg or foot. Complete blisters were formed in 13/15 cases (86.6% on the flexor aspect of the forearm, 6/11 cases (54.5% on the anterolateral thigh, and in all cases over leg. Conclusion: The flexor aspect of the forearm is a good site for suction blister harvesting.

  10. Classification of operational characteristics of commercial cup-anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T; Schmidt Paulsen, U [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1999-03-01

    The present classification of cup-anemometers is based on a procedure for classification of operational characteristics of cup-anemometers that was proposed at the EWEC `97 conference in Dublin 1997. Three definitions of wind speed are considered. The average longitudinal wind speed (ID), the average horizontal wind speed (2D) and the average vector wind speed (3D). The classification is provided in these terms, and additionally, the turbulence intensities, which are defined from the same wind speed definitions. The commercial cup-anemometers have all been calibrated in wind tunnel for the normal calibrations and angular characteristics. Friction was measured by blywheel testing, where the surrounding temperatures were varied over a wide range. The characteristics of the cup-anemometers have been fitted to the heuristic dynamic model, and the response has been calculated in time domain for prescribed ranges of external operational conditions. The results are presented in ranges of maximum deviations of `measured` average wind speed. For each definition of wind speed and turbulence intensity, the cup-anemometers are ranked according to the most precise instrument. Finally, the most important systematic error sources are commented. (au)

  11. Can a cup anemometer 'underspeed'? A heretical question

    DEFF Research Database (Denmark)

    Kristensen, L.

    2002-01-01

    An analysis of cup-anemometer dynamics has been carried out in order to determine whether the mean-wind velocity can have a negative bias. This would be contrary to the general belief that cup anemometers always overspeed. Compared to prior analyses, the effect of a possible nonlinearity...... of the calibration function is included. The conclusion is that neither longitudinal nor lateral velocity fluctuations can contribute significantly to a negative bias. However, if a cup anemometer has an angular response that falls below the ideal cosine response, there will, as demonstrated in the concluding...... discussion, be a negative contribution from the vertical velocity fluctuations to the total bias, and this contribution may even outbalance the positive contributions from the longitudinal velocity fluctuations. Concrete evidence of such exotic cup anemometer behaviour has not been reported in the literature....

  12. Suppression of the secondary flow in a suction channel of a large centrifugal pump

    International Nuclear Information System (INIS)

    Torii, D; Nagahara, T; Okihara, T

    2013-01-01

    The suction channel configuration of a large centrifugal pump with a 90-degree bend was studied in detail to suppress the secondary flow at the impeller inlet for improving suction performance. Design of experiments (DOE) and computational fluid dynamics (CFD) were used to evaluate the sensitivity of several primary design parameters of the suction channel. A DOE is a powerful tool to clarify the sensitivity of objective functions to design parameters with a minimum of trials. An L9 orthogonal array was adopted in this study and nine suction channels were designed, through which the flow was predicted by steady state calculation. The results indicate that a smaller bend radius with a longer straight nozzle, distributed between the bend and the impeller, suppresses the secondary flow at the impeller inlet. An optimum ratio of the cross sectional areas at the bend inlet and outlet was also confirmed in relationship to the contraction rate of the downstream straight nozzle. These findings were obtained by CFD and verified by experiments. The results will aid the design of large centrifugal pumps with better suction performance and higher reliability

  13. Archive-cup insert for liquid-metal sampling

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Filewicz, E.C.; Holmes, J.T.

    1975-01-01

    An insert for collecting liquid-metal samples within a vertical casing including an elongated housing with an upper and a lower overflow seal of annular shape is described. The lower seal includes a centrally located pedestal on which a sample cup is disposed. Liquid metal enters the annulus of the upper seal and overflows into the cup which fills and overflows into the lower seal. Liquid-metal overflow from the lower seal is discharged from the insert. On cooling, the liquid metal trapped within the seals solidifies to hermetically isolate the metal sample within the cup. The device is particularly applicable for use with sampling systems on liquid metal-cooled reactors. (U.S.)

  14. Cupping regulates local immunomodulation to activate neural-endocrine-immune worknet.

    Science.gov (United States)

    Guo, Yang; Chen, Bo; Wang, Dong-Qiang; Li, Ming-Yue; Lim, Calista Hui-Min; Guo, Yi; Chen, Zelin

    2017-08-01

    Research on cupping therapy is lacking at home and abroad. However, cupping and acupuncture therapy are both surface stimulation therapies. This paper suggests the mechanism of cupping therapy and proposes that the same mechanism underlies both cupping and acupuncture therapy. The microenvironment is changed when stimulating the surface of the skin, and physical signals transform into biological signals, which also interact with each other in the body. These signalling cascades activate the neuroendocrine-immune system, which produces the therapeutic effect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. An overview of systematic reviews of clinical evidence for cupping therapy

    OpenAIRE

    Huijuan Cao; Mei Han; Xiaoshu Zhu; Jianping Liu

    2015-01-01

    Background: As a traditional treatment method, cupping therapy is widely used in Asian countries. This overview of systematic reviews (SRs) investigated the effectiveness and safety of cupping therapy through an evidence-based approach. Methods: SRs that assessed the effectiveness of cupping therapy for any type of disease were searched through 6 electronic databases. Target diseases, cupping methods, numbers and types of included studies, quality of included trials, main results (includin...

  16. Prospective randomized trial compares suction versus water seal for air leaks.

    Science.gov (United States)

    Cerfolio, R J; Bass, C; Katholi, C R

    2001-05-01

    Surgeons treat air leaks differently. Our goal was to evaluate whether it is better to place chest tubes on suction or water seal for stopping air leaks after pulmonary surgery. A second goal was to evaluate a new classification system for air leaks that we developed. Patients were prospectively randomized before surgery to receive suction or water seal to their chest tubes on postoperative day (POD) #2. Air leaks were described and quantified daily by a classification system and a leak meter. The air-leak meter scored leaks from 1 (least) to 7 (greatest). The group randomized to water seal stayed on water seal unless a pneumothorax developed. On POD #2, 33 of 140 patients had an air leak. Eighteen patients had been preoperatively randomized to water seal and 15 to suction. Air leaks resolved in 12 (67%) of the water seal patients by the morning of POD #3. All 6 patients whose air leak did not stop had a leak that was 4/7 or greater (p leak meter. Of the 15 patients randomized to suction, only 1 patient's air leak (7%) resolved by the morning of POD #3. The randomization aspect of the trial was ended and statistical analysis showed water seal was superior (p = 0.001). The remaining 14 patients were then placed to water seal and by the morning of POD #4, 13 patients' leaks had stopped. Of the 32 total patients placed to seal, 7 (22%) developed a pneumothorax and 6 of these 7 patients had leaks that were 4/7 or greater (p = 0.001). Placing chest tubes on water seal seems superior to wall suction for stopping air leaks after pulmonary resection. However, water seal does not stop expiratory leaks that are 4/7 or greater. Pneumothorax may occur when chest tubes are placed on seal with leaks this large.

  17. Histogram-driven cupping correction (HDCC) in CT

    Science.gov (United States)

    Kyriakou, Y.; Meyer, M.; Lapp, R.; Kalender, W. A.

    2010-04-01

    Typical cupping correction methods are pre-processing methods which require either pre-calibration measurements or simulations of standard objects to approximate and correct for beam hardening and scatter. Some of them require the knowledge of spectra, detector characteristics, etc. The aim of this work was to develop a practical histogram-driven cupping correction (HDCC) method to post-process the reconstructed images. We use a polynomial representation of the raw-data generated by forward projection of the reconstructed images; forward and backprojection are performed on graphics processing units (GPU). The coefficients of the polynomial are optimized using a simplex minimization of the joint entropy of the CT image and its gradient. The algorithm was evaluated using simulations and measurements of homogeneous and inhomogeneous phantoms. For the measurements a C-arm flat-detector CT (FD-CT) system with a 30×40 cm2 detector, a kilovoltage on board imager (radiation therapy simulator) and a micro-CT system were used. The algorithm reduced cupping artifacts both in simulations and measurements using a fourth-order polynomial and was in good agreement to the reference. The minimization algorithm required less than 70 iterations to adjust the coefficients only performing a linear combination of basis images, thus executing without time consuming operations. HDCC reduced cupping artifacts without the necessity of pre-calibration or other scan information enabling a retrospective improvement of CT image homogeneity. However, the method can work with other cupping correction algorithms or in a calibration manner, as well.

  18. Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

    Science.gov (United States)

    Sanz-Andrés, Ángel; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance. PMID:25110735

  19. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  20. CFD Analysis of a Centrifugal Fan for Performance Enhancement using Converging Boundary Layer Suction Slots

    OpenAIRE

    K. Vasudeva Karanth; N. Yagnesh Sharma

    2009-01-01

    Generally flow behavior in centrifugal fan is observed to be in a state of instability with flow separation zones on suction surface as well as near the front shroud. Overall performance of the diffusion process in a centrifugal fan could be enhanced by judiciously introducing the boundary layer suction slots. With easy accessibility of CFD as an analytical tool, an extensive numerical whole field analysis of the effect of boundary layer suction slots in discrete regions ...

  1. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    Science.gov (United States)

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  2. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai, MD

    2017-09-01

    Full Text Available Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  3. Clinical research evidence of cupping therapy in China: a systematic literature review

    Directory of Open Access Journals (Sweden)

    Wang Qian

    2010-11-01

    Full Text Available Abstract Background Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it. This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. Methods We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. Results 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs, 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. Conclusions According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice.

  4. Clinical research evidence of cupping therapy in China: a systematic literature review.

    Science.gov (United States)

    Cao, Huijuan; Han, Mei; Li, Xun; Dong, Shangjuan; Shang, Yongmei; Wang, Qian; Xu, Shu; Liu, Jianping

    2010-11-16

    Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it.This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs), 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice.

  5. Modelling suction instabilities in soils at varying degrees of saturation

    Directory of Open Access Journals (Sweden)

    Buscarnera Giuseppe

    2016-01-01

    Full Text Available Wetting paths imparted by the natural environment and/or human activities affect the state of soils in the near-surface, promoting transitions across different regimes of saturation. This paper discusses a set of techniques aimed at quantifying the role of hydrologic processes on the hydro-mechanical stability of soil specimens subjected to saturation events. Emphasis is given to the mechanical conditions leading to coupled flow/deformation instabilities. For this purpose, energy balance arguments for three-phase systems are used to derive second-order work expressions applicable to various regimes of saturation. Controllability analyses are then performed to relate such work input with constitutive singularities that reflect the loss of strength under coupled and/or uncoupled hydro-mechanical forcing. A suction-dependent plastic model is finally used to track the evolution of stability conditions in samples subjected to wetting, thus quantifying the growth of the potential for coupled failure modes upon increasing degree of saturation. These findings are eventually linked with the properties of the field equations that govern pore pressure transients, thus disclosing a conceptual link between the onset of coupled hydro-mechanical failures and the evolution of suction with time. Such results point out that mathematical instabilities caused by a non-linear suction dependent behaviour play an important role in the advanced constitutive and/or numerical tools that are commonly used for the analysis of geomechanical problems in the unsaturated zone, and further stress that the relation between suction transients and soil deformations is a key factor for the interpretation of runaway failures caused by intense saturation events.

  6. A critical comparison of ten disposable cup LCAs

    NARCIS (Netherlands)

    Harst, van der E.J.M.; Potting, J.

    2013-01-01

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have

  7. 21 CFR 878.5040 - Suction lipoplasty system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...) Classification. Class II (special controls). Consensus standards and labeling restrictions. [63 FR 7705, Feb. 17...

  8. A level set method for cupping artifact correction in cone-beam CT

    International Nuclear Information System (INIS)

    Xie, Shipeng; Li, Haibo; Ge, Qi; Li, Chunming

    2015-01-01

    Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts in CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts

  9. Numerical simulation and analysis of cavitation flows in a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Meng, G; Tan, L; Cao, S L; Jian, W; Liu, W W; Jiang, D J

    2015-01-01

    Cavitation is an unsteady phenomenon, which is nearly inevitable in pumps. It would degrade the pump performance, generate vibrations and noises, and even erode pump flow passage components. The double suction centrifugal pump at design flow rate and large flow rate is numerically simulated using the k-ω turbulence model and the mass transport cavitation model. As a result, the calculated variation of pump head with pump inlet pressure agreed well with the experimental data. The results demonstrate that the numerical model and method can accurately predict the cavitation flows in a double suction centrifugal pump. The cavitation characteristics are analysed in great details. In addition, based on the calculation results, the reason that the plunge of pump head curve is revealed. It is found that the steep fall of pump head happens when the cavity reaches the blade to blade throat and the micro-vortex group appears at the back of the blade suction side. At the same time, this practice can provide guidance for the optimal design of double suction pumps

  10. External suction versus water seal after selective pulmonary resection for lung neoplasm: a systematic review.

    Directory of Open Access Journals (Sweden)

    Tong Qiu

    Full Text Available OBJECTIVE: To evaluate whether external suction is more advantageous than water seal in patients undergoing selective pulmonary resection (SPR for lung neoplasm. SUMMARY OF BACKGROUND DATA: Whether external suction should be routinely applied in postoperative chest drainage is still unclear, particularly for lung neoplasm patients. To most surgeons, the decision is based on their clinical experience. METHODS: Randomized control trials were selected. The participants were patients undergoing SPR with lung neoplasm. Lung volume reduction surgery and pneumothorax were excluded. Suction versus non-suction for the intervention. The primary outcome was the incidence of persistent air leak (PAL. The definition of PAL was air leak for more than 3-7 days. The secondary outcomes included air leak duration, time of drainage, postoperative hospital stay and the incidence of postoperative pneumothorax. Studies were identified from literature collections through screening. Bias was analyzed and meta-analysis was used. RESULTS: From the 1824 potentially relevant trials, 6 randomized control trials involving 676 patients were included. There was no difference between external suction and water seal in decreasing the incidence of PAL [95% confidence interval (CI 0.81-2.16; z = 1.10; P = 0.27]. Regarding secondary outcomes, there were no differences in time of drainage (95% CI-0.36-1.56, P = 0.22, postoperative hospital stay (95% CI -.31-.54, P = 0.87 or incidence of postoperative pneumothorax (95% CI 0.18-.02, P = 0.05 between external suction and water seal. CONCLUSIONS: For participants, no differences are identified in terms of PAL incidence, drainage time, length of postoperative hospital stay or incidence of postoperative pneumothorax between external suction and water seal. The bias analysis should be emphasized. To the limitations of the bias and methodological differences among the included studies, we have no recommendation on

  11. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    Science.gov (United States)

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  12. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

    Science.gov (United States)

    von Schulze Pellengahr, Christoph; von Engelhardt, Lars V; Wegener, Bernd; Müller, Peter E; Fottner, Andreas; Weber, Patrick; Ackermann, Ole; Lahner, Matthias; Teske, Wolfram

    2015-04-21

    Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for

  13. Cup detachment during vacuum-assisted vaginal delivery and birth outcome.

    Science.gov (United States)

    Krispin, Eyal; Aviram, Amir; Salman, Lina; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-11-01

    To determine the perinatal outcome associated with cup detachment during vacuum-assisted vaginal delivery (VAVD). A retrospective cohort study of all women attempting VAVD in a tertiary hospital (2012-2014). Singleton-term pregnancies were included. Antepartum fetal death and major fetal structural or chromosomal abnormalities were excluded. Primary outcome was neonatal birth trauma (subgaleal hematoma, subarachnoid hematoma, subdural hematoma, skull fracture, and/or erb's palsy). Secondary outcomes were maternal complications or other neonatal morbidities. Outcomes were compared between women after ≥1 cup detachment (study group) and the rest (control group). Logistic regression analysis was utilized to adjust results to potential confounders. Overall, 1779 women attempted VAVD during study period. Of them, in 146 (8.2%), the cup detached prior to delivery; 130/146 (89%) had a single detachment. After detachment, 4 (2.7%) delivered by cesarean section, 77 (52.7%) delivered after cup reapplication, and 65 (44.6%) delivered spontaneously. Women in the study group were more likely to undergo VAVD due to prolonged second stage, and were characterized by lower rates of metal cup use. Neonates in the detachment group had higher rates of subarachnoid hematoma and composite neonatal birth trauma (2.7 vs. 0.1% and 4.8 vs. 1.8%, respectively, p Cup detachment is associated with a higher rate of adverse neonatal outcome. Cup reapplication should be considered carefully.

  14. [Development of lipoma following a single cupping massage - a case report].

    Science.gov (United States)

    Schumann, Stefan; Lauche, Romy; Hohmann, Claudia; Zirbes, Thomas; Dobos, Gustav; Saha, Felix Joyonto

    2012-01-01

    The cupping massage is a form of bloodless cupping. This type of cupping is particularly used to treat muscular tension and musculoskeletal pain, such as chronic neck pain; however the data records on mechanisms and potential side effects are not satisfactory. In a study on the effectiveness of cupping massage in patients with chronic neck pain, one patient showed a formation of a lipoma in the cupping area after the first treatment session. Because of the short time interval between therapy and development of the lipoma, a primary cause is not realistic. This adverse event has not been described in the literature before, and the present report describes the case in summary.

  15. 21 CFR 878.4780 - Powered suction pump.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be used to remove infectious materials from wounds or fluids from a patient's airway or respiratory support system. The device may be used during surgery in the operating room or at the patient's bedside...

  16. Contact of dual mobility implants: effects of cup wear and inclination.

    Science.gov (United States)

    Uddin, M S

    2015-01-01

    Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies.

  17. A Facile Approach to Evaluate Thermal Insulation Performance of Paper Cups

    Directory of Open Access Journals (Sweden)

    Yudi Kuang

    2015-01-01

    Full Text Available Paper cups are ubiquitous in daily life for serving water, soup, coffee, tea, and milk due to their convenience, biodegradability, recyclability, and sustainability. The thermal insulation performance of paper cups is of significance because they are used to supply hot food or drinks. Using an effective thermal conductivity to accurately evaluate the thermal insulation performance of paper cups is complex due to the inclusion of complicated components and a multilayer structure. Moreover, an effective thermal conductivity is unsuitable for evaluating thermal insulation performance of paper cups in the case of fluctuating temperature. In this work, we propose a facile approach to precisely analyze the thermal insulation performance of paper cups in a particular range of temperature by using an evaluation model based on the MISO (Multiple-Input Single-Output technical theory, which includes a characterization parameter (temperature factor and a measurement apparatus. A series of experiments was conducted according to this evaluation model, and the results show that this evaluation model enables accurate characterization of the thermal insulation performance of paper cups and provides an efficient theoretical basis for selecting paper materials for paper cups.

  18. Why it is harder to run RoboCup in South Africa

    Directory of Open Access Journals (Sweden)

    Alexander Ferrein

    2016-10-01

    Full Text Available Robots are widely used as a vehicle to spark interest in science and technology in learners. A number of initiatives focus on this issue, for instance, the Roberta Initiative, the FIRST Lego League, the World Robot Olympiad and RoboCup Junior. Robotic competitions are valuable not only for school learners but also for university students, as the RoboCup initiative shows. Besides technical skills, the students get some project exposure and experience what it means to finish their tasks on time. But qualifying students for future high-tech areas should not only be for students from developed countries. In this article, we present our experiences with research and education in robotics within the RoboCup initiative, in Germany and South Africa; we report on our experiences with trying to get the RoboCup initiative in South Africa going. RoboCup has a huge support base of academic institutions in Germany; this is not the case in South Africa. We present our ‘north–south’ collaboration initiatives in RoboCup between Germany and South Africa and discuss some of the reasons why we think it is harder to run RoboCup in South Africa.

  19. Development of an external Faraday cup for beam current measurements

    International Nuclear Information System (INIS)

    Kim, Kye-Ryung; Jung, Myung-Hwan; Ra, Se-Jin; Lee, Seok-Ki

    2010-01-01

    In general, beam current measurements are very important for many kinds of experiments using highly energetic particle beams at accelerators, such as cyclotrons, linacs, etc. The Faraday cup is known to be one of the most popular beam current measurement tools. We developed an external Faraday cup to measure the beam current at a dedicated beam line for low-flux experiments installed at the MC-50 cyclotron of Korea Institute of Radiological and Medical Sciences (KIRAMS). It was designed for external beam current measurements and is composed of a vacuum chamber, an entrance window, a collimator, a electrostatic suppressor ring, and a cup. The window is made of 75-um-thick Kapton film, and the diameter of the collimator is 10 mm or 20 mm. The ring and the cup has 5-cm inner diameters, and the thickness of the bottom of the cup is 2 cm, which is enough to absorb the total proton energy up to 45 MeV. Using this external Faraday cup, we measured the beam current from the cyclotron, and we compared measured flux to the results from film dosimetry using GAF films.

  20. Sound of a cup with and without instant coffee

    Science.gov (United States)

    Morrison, Andrew; Rossing, Thomas D.

    2002-05-01

    An empty coffee cup, like an ancient Chinese two-tone bell, emits two distinctly different tones, depending upon where it is tapped. When it is filled with hot water, and some instant coffee is added, however, a whole new set of sounds is heard when the cup is tapped. The pitch rises an octave or more as the foam clears due to the dramatic change in the speed of sound in the bubble-filled liquid. A similar, but smaller, effect was noted in beer by Bragg [The World of Sound (1968)] and in hot chocolate by Crawford [Am. J. Phys. (1982)]. We describe the modes of vibration in a coffee cup and the sound emitted by a coffee cup as filled with instant coffee as the bubble density changes.

  1. Time management and nectar flow: flower handling and suction feeding in long-proboscid flies (Nemestrinidae: Prosoeca)

    Science.gov (United States)

    Karolyi, Florian; Morawetz, Linde; Colville, Jonathan F.; Handschuh, Stephan; Metscher, Brian D.; Krenn, Harald W.

    2013-11-01

    A well-developed suction pump in the head represents an important adaptation for nectar-feeding insects, such as Hymenoptera, Lepidoptera and Diptera. This pumping organ creates a pressure gradient along the proboscis, which is responsible for nectar uptake. The extremely elongated proboscis of the genus Prosoeca (Nemestrinidae) evolved as an adaptation to feeding from long, tubular flowers. According to the functional constraint hypothesis, nectar uptake through a disproportionately elongated, straw-like proboscis increases flower handling time and consequently lowers the energy intake rate. Due to the conspicuous length variation of the proboscis of Prosoeca, individuals with longer proboscides are hypothesised to have longer handling times. To test this hypothesis, we used field video analyses of flower-visiting behaviour, detailed examinations of the suction pump morphology and correlations of proboscis length with body length and suction pump dimensions. Using a biomechanical framework described for nectar-feeding Lepidoptera in relation to proboscis length and suction pump musculature, we describe and contrast the system in long-proboscid flies. Flies with longer proboscides spent significantly more time drinking from flowers. In addition, proboscis length and body length showed a positive allometric relationship. Furthermore, adaptations of the suction pump included an allometric relationship between proboscis length and suction pump muscle volume and a combination of two pumping organs. Overall, the study gives detailed insight into the adaptations required for long-proboscid nectar feeding, and comparisons with other nectar-sucking insects allow further considerations of the evolution of the suction pump in insects with sucking mouthparts.

  2. Half versus full vacuum suction drainage after modified radical mastectomy for breast cancer- a prospective randomized clinical trial[ISRCTN24484328

    Directory of Open Access Journals (Sweden)

    Singh JP

    2005-01-01

    Full Text Available Abstract Background Suction drains are routinely used after modified radical mastectomy and are an important factor contributing to increased hospital stay as the patients are often discharged only after their removal. Amongst various factors that influence the amount of postoperative drainage, the negative suction pressure applied to the drain has been reported to be of great significance. While a high negative suction pressure is expected to drain the collection and reduce the dead space promptly, it may also prevent the leaking lymphatics from closing and lead to increased drainage from the wound. Against this background a prospective randomized clinical study was conducted to compare the amount and duration of drainage between a half negative suction and full vacuum suction drainage in patients following modified radical mastectomy. The associated postoperative morbidity was also compared between the two groups. Methods 85 FNAC (fine needle aspiration cytology proven cases of locally advanced breast cancer were randomized. (Using randomly ordered sealed envelops, which were opened immediately before the closure of the wound in to 50 patients with full vacuum suction (pressure = 700 g/m2 and 35 cases in to half vacuum suction drainage (pressure = 350 g/m2 groups. The two groups were comparable in respect of age, weight, and technique of operation and extent of axillary dissection. Surgery was performed by the same surgical team comprising of five surgeons (two senior and three resident surgeons using a standardized technique with electrocautery. External compression dressing was provided over the axilla for first 48 hrs and following that patients were encouraged to do active and passive shoulder exercises. The outcomes measured were postoperative morbidity and the length of hospital stay. Statistical methods used: Descriptive studies were performed with SPSS version 10 and group characteristics were compared using student t-test. Results

  3. Brazil World Cup Challenges

    Directory of Open Access Journals (Sweden)

    MANSUR, R.

    2012-12-01

    Full Text Available Overcoming the productivity challenge is the main benefit of the 2014 World Cup for Brazilian people. The sustainable development of our cultural tourism industry will catapult the new middle class growing up rate.

  4. Effects of suction-dredging for cockles on non-target fauna in the Wadden Sea

    NARCIS (Netherlands)

    Hiddink, JG

    2003-01-01

    Suction dredging for cockles removes large cockles from tidal flats and may also cause mortality of non-target fauna and make the habitat less suitable for some species. This study examines whether suction dredging for cockles on tidal flats of the Dutch Wadden Sea had affected densities of

  5. Wear numbers for ball cup and journal bearings

    NARCIS (Netherlands)

    Ligterink, D.J.; Moes, H.

    1980-01-01

    A wear number is defined for ball cup bearings and for journal bearings where the cup and the cylindrical bearing are made of soft material. This dimensionless wear number provides a relation between the following five quantities: the radius of the ball or the length of the journal bearing in

  6. CUP promotes deadenylation and inhibits decapping of mRNA targets

    Science.gov (United States)

    Igreja, Catia; Izaurralde, Elisa

    2011-01-01

    CUP is an eIF4E-binding protein (4E-BP) that represses the expression of specific maternal mRNAs prior to their posterior localization. Here, we show that CUP employs multiple mechanisms to repress the expression of target mRNAs. In addition to inducing translational repression, CUP maintains mRNA targets in a repressed state by promoting their deadenylation and protects deadenylated mRNAs from further degradation. Translational repression and deadenylation are independent of eIF4E binding and require both the middle and C-terminal regions of CUP, which collectively we termed the effector domain. This domain associates with the deadenylase complex CAF1–CCR4–NOT and decapping activators. Accordingly, in isolation, the effector domain is a potent trigger of mRNA degradation and promotes deadenylation, decapping and decay. However, in the context of the full-length CUP protein, the decapping and decay mediated by the effector domain are inhibited, and target mRNAs are maintained in a deadenylated, repressed form. Remarkably, an N-terminal regulatory domain containing a noncanonical eIF4E-binding motif is required to protect CUP-associated mRNAs from decapping and further degradation, suggesting that this domain counteracts the activity of the effector domain. Our findings indicate that the mode of action of CUP is more complex than previously thought and provide mechanistic insight into the regulation of mRNA expression by 4E-BPs. PMID:21937713

  7. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  8. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    Science.gov (United States)

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  9. Magnetohydrodynamic peristaltic motion of a Newtonian fluid through porous walls through suction and injection

    Science.gov (United States)

    Sivaiah, R.; Hemadri Reddy, R.

    2017-11-01

    In this paper, we investigate the peristaltic transport of a conducting Newtonian fluid bounded by permeable walls with suction and injection moving with constant velocity of the wave in the wave frame of reference under the consideration of long wavelength and low Reynolds number. The analytical solution for the velocity field, pressure gradient and the frictional force are obtained. The effect of suction/injection parameter, amplitude ratio and the permeability parameter including slip on the flow quantities are discussed graphically. It is found that the greater the suction/injection parameter, the smaller the pressure rise against the pump works. Further, the pressure rise increases with increasing Magnetic parameter.

  10. Present knowledge about Laboratory Testing of Axial Loading on Suction Caissons

    DEFF Research Database (Denmark)

    Manzotti, E.; Vaitkunaite, Evelina; Ibsen, Lars Bo

    Offshore wind turbines are increasing in both efficiency and size. More economical foundations for such light structures are under investigation, and suction caisson was shown to be particularly suitable for this purpose. In multi-pod foundation configuration, the overturning moment given by loads...... on the structure is resisted by push-pull loads on the vertical axis of each suction caisson. Relevant works where this situation is examined by means of laboratory testing are summarized in this article, then different conclusions are followed by discussion and comparison. In the initial theoretical section...

  11. Effects of vacuum suctioning and strategic drape tenting on oxygen concentration in a simulated surgical field.

    Science.gov (United States)

    Kung, Theodore A; Kong, Sarah W; Aliu, Oluseyi; Azizi, Jahan; Kai, Salim; Cederna, Paul S

    2016-02-01

    To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting. Experimental. Clinical simulation center of a university-affiliated hospital. Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula. Vacuum suctioning and strategic drape tenting. The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%. In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P strategic tenting (110 seconds; P strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    Science.gov (United States)

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Effect of dispersed phase particle size on microstructure of cup fracture

    International Nuclear Information System (INIS)

    Goritskij, V.M.; Guseva, I.A.

    1978-01-01

    A correlation-regressive analysis has been carried out to reveal the influence of the size and the mean distance between the disperse particles of deposits V(C,N) on the microstructure (size of micropores and cups, density of the cups) of a viscous cup-like fracture of specimens made of 30Kh2NMFA grade steel that has been hardened and annealed. It is shown that micropores develop at relatively large particles of deposits V(C,N) (>=0.04/m). A strong correlation linear connection exists between the size of a disperse particle of deposits V(C,N), the size of micropore and cup. This connection is attributable to the close, pairwise correlative connection between the size of the particle and the micropore, the micropore and the cup

  14. Development of Energy Efficiency Design Map based on acoustic resonance frequency of suction muffler in compressor

    International Nuclear Information System (INIS)

    Oh, Seungjae; Wang, Semyung; Cho, Sungman

    2015-01-01

    Highlights: • Development of Energy Efficiency Design Map. • Experimental validation of Energy Efficiency Design Map. • Suggestion regarding the Acoustically Supercharged Energy Efficiency. • Sensitivity analysis of the Energy Efficiency Ratio with respect to acoustic pressure. • Suggestion regarding the hybrid coupling method for acoustic analysis in compressor. - Abstract: The volumetric efficiency of the Internal Combustion (IC) engine and compressor can be increased by properly adjusting the acoustic resonance frequency of the suction muffler or the suction valve timing without any additional equipment or power source. This effect is known as acoustic supercharging. However, the energy efficiency has become more important than the volumetric efficiency because of the energy shortage issue and factors influencing consumers’ purchasing decisions. Therefore, methods for increasing the energy efficiency using the acoustic effect in the suction part of IC engine and compressor should be considered. In this study, a systematic method for improving the energy efficiency using the acoustic effect in the suction part of the compressor used in refrigerators and air conditioners was developed for the first time. This effect is named as the Acoustically Supercharged Energy Efficiency (ASEE). For the ASEE, first, a hybrid coupling method was suggested for the acoustical analysis in the suction part of the compressor. Next, an Energy Efficiency Design Map (EEDM) was proposed. This can serve as a design guide for suction mufflers in terms of the energy efficiency. Finally, sensitivity analyses of the Energy Efficiency Ratio (EER) and total massflow rate with respect to the acoustic pressure were conducted to identify the relationship between the acoustic pressure and the suction valve motion. This provides the physical background for the EEDM

  15. Cupping for chronic nonspecific neck pain: a 2-year follow-up.

    Science.gov (United States)

    Lauche, Romy; Cramer, Holger; Langhorst, Jost; Dobos, Gustav

    2013-01-01

    Several trials have shown that cupping might be an effective treatment for chronic nonspecific neck pain, but little is known about the long-term effectiveness. This study aimed to investigate long-term effects of a short series of cupping; therefore additional follow-up measurements were conducted 2 years after completion of 3 studies. Participants from 3 randomized waitlist controlled trials on cupping for chronic nonspecific neck pain were followed 2 years after treatment. Outcome measures included neck pain intensity (100 mm Visual Analog Scale; VAS), functional disability (Neck Disability Index, NDI), and health-related quality of life (Short Form 36 Health Survey Questionnaire; SF-36). 133 of 150 patients had received cupping treatment and were contacted; 82 of them (61.7%) returned the follow-up questionnaires. No effect was found for neck pain intensity, but for physical function (∆ NDI: -3.15; 95% CI: -5.89; -0.41; p = 0.025) and quality of life (∆ physical component summary: 2.97; 95% CI: 0.97; 4.97; p = 0.004; ∆ bodily pain: 14.53; 95 % CI: 9.67; 19.39; p cupping effect was 8.9 ± 8.7 months with 16 patients reporting that neck pain had not yet reached the level before cupping. The majority of the patients did not continue cupping therapy, mostly due to lack of providers, costs or loss of interest. A series of cupping treatments did not influence neck pain intensity on the longer term, however significant increases were found for physical function and quality of life in patients with chronic nonspecific neck pain. Due to the considerable drop-out rate conclusions are limited. There is evidence suggesting that cupping treatment might have sustainable effects in some patients. Further randomized controlled trials with long-term follow-up are urgently needed for conclusive judgment of long-term effectiveness. © 2013 S. Karger GmbH, Freiburg.

  16. Urine cup for collection of urine from cows.

    Science.gov (United States)

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  17. Faraday cup for analyzing multi-ion plasma

    International Nuclear Information System (INIS)

    Fujita, Takao

    1987-01-01

    A compact and convenient ion analyzer (a kind of a Faraday cup) is developed in order to analyze weakly ionized multi-ion plasmas. This Faraday cup consists of three mesh electrodes and a movable ion collector. With a negative gate pulse superimposed on the ion retarding bias, ions are analyzed by means of time-of-flight. The identification of ion species and measurements of ion density and ion temperature are studied. (author)

  18. Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries

    Science.gov (United States)

    2017-11-13

    Airway Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries...Consumer Style Comparison Table of Suction Pump Devices ............................. 103 Appendix H – Web Links for Images for Consumer- Style ...0022 pg. 6 Executive Summary Suction is a critical component of airway management , which is the second leading cause of preventable

  19. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  20. Complementary Coffee Cups

    Science.gov (United States)

    Banchoff, Thomas

    2006-01-01

    What may have been the birth of a new calculus problem took place when the author noticed that two coffee cups, one convex and one concave, fit nicely together, and he wondered which held more coffee. The fact that their volumes were about equal led to the topic of this article: complementary surfaces of revolution with equal volumes.

  1. Cup Anemometer Overspeeding

    DEFF Research Database (Denmark)

    Busch, N. E.; Kristensen, Leif

    1976-01-01

    Statistical considerations are applied to a general equation of motion for cup anemometers in a turbulent wind. It is shown that the relative overspeeding ΔS/S can be expressed as ΔS/S = Ih2 · Js(l0/Λs) + cIw2, where Is and Iw are the horizontal and the vertical turbulence intensifies, respectively...

  2. Cup regulates oskar mRNA stability during oogenesis.

    Science.gov (United States)

    Broyer, Risa M; Monfort, Elena; Wilhelm, James E

    2017-01-01

    The proper regulation of the localization, translation, and stability of maternally deposited transcripts is essential for embryonic development in many organisms. These different forms of regulation are mediated by the various protein subunits of the ribonucleoprotein (RNP) complexes that assemble on maternal mRNAs. However, while many of the subunits that regulate the localization and translation of maternal transcripts have been identified, relatively little is known about how maternal mRNAs are stockpiled and stored in a stable form to support early development. One of the best characterized regulators of maternal transcripts is Cup - a broadly conserved component of the maternal RNP complex that in Drosophila acts as a translational repressor of the localized message oskar. In this study, we have found that loss of cup disrupts the localization of both the oskar mRNA and its associated proteins to the posterior pole of the developing oocyte. This defect is not due to a failure to specify the oocyte or to disruption of RNP transport. Rather, the localization defects are due to a drop in oskar mRNA levels in cup mutant egg chambers. Thus, in addition to its role in regulating oskar mRNA translation, Cup also plays a critical role in controlling the stability of the oskar transcript. This suggests that Cup is ideally positioned to coordinate the translational control function of the maternal RNP complex with its role in storing maternal transcripts in a stable form. Published by Elsevier Inc.

  3. A new technique for radiographic measurement of acetabular cup orientation.

    Science.gov (United States)

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  4. Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT.

    Science.gov (United States)

    Kim, Young Kook; Ha, Ahnul; Lee, Won June; Jeoung, Jin Wook; Park, Ki Ho

    2017-12-01

    To introduce the measurement method of optic disc cup surface depth using spectral-domain optical coherence tomography (SD-OCT) and then evaluate the rates of cup surface depression at 3 different stages of glaucoma. We retrospectively identified 52 eyes with preperimetric glaucoma, 56 with mild-or-moderate glaucoma and 50 with severe glaucoma and followed them for at least 48 months. Eyes were imaged using SD-OCT (Cirrus HD-OCT) at 12-month intervals. The mean cup surface depth was calculated using the following formula: Cup volume/(disc area×average cup-to-disc ratio)-200 μm. The rates of mean cup surface depression (μm/y) were significantly greater in mild-or-moderate glaucoma (-7.96±1.03) than in preperimetric (-3.11±0.61) and severe glaucoma (-0.70±0.12; all Pcup surface depression (%/y) were significantly greater than those of average of retinal nerve fiber layer (RNFL) thinning (%/y) in preperimetric glaucoma (-1.64±0.12 vs. -1.11±0.07; Pcup surface depth changed slower than did average RNFL thickness (-0.64±0.06 vs. -0.75±0.08%/y; Pcup surface depth changed faster than did the RNFL thickness. These results signify the possibility that SD-OCT-based estimation of cup surface depth might be useful for monitoring of glaucoma development and progression.

  5. Dynamic behaviour of suction caissons

    Energy Technology Data Exchange (ETDEWEB)

    Liingaard, M.

    2006-12-15

    Offshore wind energy is a promising source of energy in the near future, and is rapidly becoming competitive with other power generating technologies. The continuous improvement in wind turbine technology means that the wind turbines have increased tremendously in both size and performance during the last 25 years. In order to reduce the costs, the overall weight of the wind turbine components is minimized, which means that the wind turbine structures become more flexible and thus more sensitive to dynamic excitation. Since the first resonance frequency of the modern offshore wind turbines is close to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary to account for the possibilities of dynamic effects of the soil-structure interaction. The aim of this thesis is to evaluate the dynamic soil-structure interaction of foundations for offshore wind turbines, with the intention that the dynamic properties of the foundation can be properly included in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil is simplified as a homogenous linear viscoelastic material. The dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequencydependent coefficients corresponding to the different degrees of freedom. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the

  6. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  7. A comparison of commercial light-emitting diode baited suction traps for surveillance of Culicoides in northern Europe.

    Science.gov (United States)

    Hope, Andrew; Gubbins, Simon; Sanders, Christopher; Denison, Eric; Barber, James; Stubbins, Francesca; Baylis, Matthew; Carpenter, Simon

    2015-04-22

    The response of Culicoides biting midges (Diptera: Ceratopogonidae) to artificial light sources has led to the use of light-suction traps in surveillance programmes. Recent integration of light emitting diodes (LED) in traps improves flexibility in trapping through reduced power requirements and also allows the wavelength of light used for trapping to be customized. This study investigates the responses of Culicoides to LED light-suction traps emitting different wavelengths of light to make recommendations for use in surveillance. The abundance and diversity of Culicoides collected using commercially available traps fitted with Light Emitting Diode (LED) platforms emitting ultraviolet (UV) (390 nm wavelength), blue (430 nm), green (570 nm), yellow (590 nm), red (660 nm) or white light (425 nm - 750 nm with peaks at 450 nm and 580 nm) were compared. A Centre for Disease Control (CDC) UV light-suction trap was also included within the experimental design which was fitted with a 4 watt UV tube (320-420 nm). Generalised linear models with negative binomial error structure and log-link function were used to compare trap abundance according to LED colour, meteorological conditions and seasonality. The experiment was conducted over 49 nights with 42,766 Culicoides caught in 329 collections. Culicoides obsoletus Meigen and Culicoides scoticus Downes and Kettle responded indiscriminately to all wavelengths of LED used with the exception of red which was significantly less attractive. In contrast, Culicoides dewulfi Goetghebuer and Culicoides pulicaris Linnaeus were found in significantly greater numbers in the green LED trap than in the UV LED trap. The LED traps collected significantly fewer Culicoides than the standard CDC UV light-suction trap. Catches of Culicoides were reduced in LED traps when compared to the standard CDC UV trap, however, their reduced power requirement and small size fulfils a requirement for trapping in logistically challenging areas or where many

  8. Dry cupping for plantar fasciitis: a randomized controlled trial.

    Science.gov (United States)

    Ge, Weiqing; Leson, Chelsea; Vukovic, Corey

    2017-05-01

    [Purpose] The purpose of this study was to determine the effects of dry cupping on pain and function of patients with plantar fasciitis. [Subjects and Methods] Twenty-nine subjects (age 15 to 59 years old, 20 females and 9 males), randomly assigned into the two groups (dry cupping therapy and electrical stimulation therapy groups), participated in this study. The research design was a randomized controlled trial (RCT). Treatments were provided to the subjects twice a week for 4 weeks. Outcome measurements included the Visual Analogue Pain Scale (VAS) (at rest, first in the morning, and with activities), the Foot and Ankle Ability Measure (FAAM), the Lower Extremity Functional Scale (LEFS), as well as the pressure pain threshold. [Results]The data indicated that both dry cupping therapy and electrical stimulation therapy could reduce pain and increase function significantly in the population tested, as all the 95% Confidence Intervals (CIs) did not include 0 except for the pressure pain threshold. There was no significant difference between the dry cupping therapy and electrical stimulation groups in all the outcome measurements. [Conclusion] These results support that both dry cupping therapy and electrical stimulation therapy could reduce pain and increase function in the population tested.

  9. Vortex cavitation and oscillation in a double-suction volute pump

    International Nuclear Information System (INIS)

    Sato, T; Nagahara, T; Tanaka, K; Fuchiwaki, M; Shimizu, F

    2010-01-01

    In recent years, Computational Fluid Dynamics (CFD) codes have been utilized actively in the early part of the product development cycle. Numerical analysis models have also been developed rapidly and have added cavitation flow analysis functions peculiar to hydraulic machines, in which the flow analysis has been developed remarkably with high-precision and high-reliability. On the other hand, it is well known that three kinds of cavitation, such as vortex cavitation, reverse flow cavitation and cloud cavitation appear in a double-suction volute pump. We have much interest in a relationship among the cavitating flows, pump oscillation and noise. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in the pump and pump oscillation which causes cavitation noise from the pump. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

  10. Development and calibration of a self-recording cup anemometer for ...

    African Journals Online (AJOL)

    UFUOMA

    The instrument design consists of six electronics block stages: Power stage which supplies ... Key words: Wind speed, cup anemometer, sensor, decoder, spindle. INTRODUCTION ... and develop a low cost digital cup anemometer, which is.

  11. Response of skirted suction caissons to monotonic lateral loading in saturated medium sand

    Science.gov (United States)

    Li, Da-yong; Zhang, Yu-kun; Feng, Ling-yun; Guo, Yan-xue

    2014-08-01

    Monotonic lateral load model tests were carried out on steel skirted suction caissons embedded in the saturated medium sand to study the bearing capacity. A three-dimensional continuum finite element model was developed with Z_SOIL software. The numerical model was calibrated against experimental results. Soil deformation and earth pressures on skirted caissons were investigated by using the finite element model to extend the model tests. It shows that the "skirted" structure can significantly increase the lateral capacity and limit the deflection, especially suitable for offshore wind turbines, compared with regular suction caissons without the "skirted" at the same load level. In addition, appropriate determination of rotation centers plays a crucial role in calculating the lateral capacity by using the analytical method. It was also found that the rotation center is related to dimensions of skirted suction caissons and loading process, i.e. the rotation center moves upwards with the increase of the "skirted" width and length; moreover, the rotation center moves downwards with the increase of loading and keeps constant when all the sand along the caisson's wall yields. It is so complex that we cannot simply determine its position like the regular suction caisson commonly with a specified position to the length ratio of the caisson.

  12. Characterisation and classification of RISOe P2546 cup anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.

    2004-03-01

    The characteristics of the RISOe P2546 cup anemometer were investigated in detail, and all data presented in figures and tables. The characteristics include: wind tunnel calibrations, including an accredited calibration; tilt response meas-urements for tilt angles from -40 deg. C to 40 deg. C; gust response measurements at 8m/s, 10,5m/s and 13m/s and turbulence intensities of 10%, 16% and 23%; step response measurements at step wind speeds 4, 8, 12 and 15m/s; measurement of torque characteristics at 8m/s; rotor inertia measurements and measurements of friction of bearings at temperatures -20 deg. C to 40 deg. C. The characteristics are fitted to a time domain cup anemometer model, and the cup anemometer is put into the CLASSCUP classification scheme. The characteristics are also compared to the requirements to cup anemometers in the Danish wind turbine certification system and the CD and CDV of the revision of the standard IEC 61400-12. (au)

  13. Clad vent set cup open end (closure weld zone) wall-thickness study

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, G.B.; Sherrill, M.W.

    1994-09-01

    The wall thickness at the open end of Clad Vent Set (CVS) cups is a very important parameter for maintaining control of the fueled CVS closure weld process. Ideally, the wall thickness in the closure weld zone should be constant. The DOP-26 iridium alloy is very difficult to machine; therefore, key dimensional features are established during the two-draw warm-forming operation. Unfortunately, anisotropy in the forming blanks produces four ears at the open end of each cup. Formation of these ears produces axial and circumferential variations in wall thickness. The cup certification requirement is that the wall thickness in the closure weld zone, defined as the 2.5-mm band at the open end of a cup, measure from 0.63 to 0.73 mm. The wall thickness certification data for the open end of the CVS cups have been statistically evaluated. These data show that the cups recently produced for the Cassini mission have well-controlled open-end wall thicknesses.

  14. Up for the Cup.

    Science.gov (United States)

    Lawson, Duncan A.

    1996-01-01

    Presents an activity related to probability in order to answer a question based on the English football league. The question is "What is the probability that the FA Cup Final will be between the same two teams that played in the previous tournament?". (ASK)

  15. A low-mass faraday cup experiment for the solar wind

    Science.gov (United States)

    Lazarus, A. J.; Steinberg, J. T.; Mcnutt, R. L., Jr.

    1993-01-01

    Faraday cups have proven to be very reliable and accurate instruments capable of making 3-D velocity distribution measurements on spinning or 3-axis stabilized spacecraft. Faraday cup instrumentation continues to be appropriate for heliospheric missions. As an example, the reductions in mass possible relative to the solar wind detection system about to be flown on the WIND spacecraft were estimated. Through the use of technology developed or used at the MIT Center for Space Research but were not able to utilize for WIND: surface-mount packaging, field-programmable gate arrays, an optically-switched high voltage supply, and an integrated-circuit power converter, it was estimated that the mass of the Faraday Cup system could be reduced from 5 kg to 1.8 kg. Further redesign of the electronics incorporating hybrid integrated circuits as well as a decrease in the sensor size, with a corresponding increase in measurement cycle time, could lead to a significantly lower mass for other mission applications. Reduction in mass of the entire spacecraft-experiment system is critically dependent on early and continual collaborative efforts between the spacecraft engineers and the experimenters. Those efforts concern a range of issues from spacecraft structure to data systems to the spacecraft power voltage levels. Requirements for flight qualification affect use of newer, lighter electronics packaging and its implementation; the issue of quality assurance needs to be specifically addressed. Lower cost and reduced mass can best be achieved through the efforts of a relatively small group dedicated to the success of the mission. Such a group needs a fixed budget and greater control over quality assurance requirements, together with a reasonable oversight mechanism.

  16. The pvc operon regulates the expression of the Pseudomonas aeruginosa fimbrial chaperone/usher pathway (cup genes.

    Directory of Open Access Journals (Sweden)

    Uzma Qaisar

    Full Text Available The Pseudomonas aeruginosa fimbrial structures encoded by the cup gene clusters (cupB and cupC contribute to its attachment to abiotic surfaces and biofilm formation. The P. aeruginosa pvcABCD gene cluster encodes enzymes that synthesize a novel isonitrile functionalized cumarin, paerucumarin. Paerucumarin has already been characterized chemically, but this is the first report elucidating its role in bacterial biology. We examined the relationship between the pvc operon and the cup gene clusters in the P. aeruginosa strain MPAO1. Mutations within the pvc genes compromised biofilm development and significantly reduced the expression of cupB1-6 and cupC1-3, as well as different genes of the cupB/cupC two-component regulatory systems, roc1/roc2. Adjacent to pvc is the transcriptional regulator ptxR. A ptxR mutation in MPAO1 significantly reduced the expression of the pvc genes, the cupB/cupC genes, and the roc1/roc2 genes. Overexpression of the intact chromosomally-encoded pvc operon by a ptxR plasmid significantly enhanced cupB2, cupC2, rocS1, and rocS2 expression and biofilm development. Exogenously added paerucumarin significantly increased the expression of cupB2, cupC2, rocS1 and rocS2 in the pvcA mutant. Our results suggest that pvc influences P. aeruginosa biofilm development through the cup gene clusters in a pathway that involves paerucumarin, PtxR, and different cup regulators.

  17. Supermarket refrigeration. Optimization of suction pressure in existing refrigerators; Supermarktkaelte. Saugdruck optimieren in Bestandskaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Philipp; Mueller, Markus [Eckelmann AG, Wiesbaden (Germany)

    2012-06-15

    The new E*LDS firmware E*COP{sup +} from Eckelmann AG (Wiesbaden, Federal Republic of Germany) for the optimization of the suction pressure supplies a demand-oriented adaptation of the suction pressure. The new feature is ideal for an update of existing systems with thermostatic expansion valves. Using this update operators of supermarket operators may save about 10% energy with little effort.

  18. Natural convection boundary layer with suction and mass transfer in a porous medium

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1989-03-01

    The free convection boundary layer flow with simultaneous heat and mass transfer in a porous medium is studied when the boundary wall moves in its own plane with suction. The study also incorporates chemical reaction for the very simple model of a binary reaction with Arrhenius activation energy. For large suction asymptotic approximate solutions are obtained for the flow variables for various values of the activation energy. (author). 10 refs, 2 figs

  19. Köebner phenomenon induced by cupping therapy in a psoriasis patient.

    Science.gov (United States)

    Yu, Rui-Xing; Hui, Yun; Li, Cheng-Rang

    2013-06-15

    Psoriasis is a chronic, immune-mediated inflammatory and refractory disease. The koebner phenomenon, which can be induced by trauma, is common in psoriasis patients. Herein, we report a patient with psoriasis who was treated by cupping therapy and subsequently developed the koebner phenomenon (KP) at the cupped sites. To our knowledge, it is the first report about cupping therapy leading to KP in a psoriasis patient.

  20. Cup Implant Planning Based on 2-D/3-D Radiographic Pelvis Reconstruction-First Clinical Results.

    Science.gov (United States)

    Schumann, Steffen; Sato, Yoshinobu; Nakanishi, Yuki; Yokota, Futoshi; Takao, Masaki; Sugano, Nobuhiko; Zheng, Guoyan

    2015-11-01

    In the following, we will present a newly developed X-ray calibration phantom and its integration for 2-D/3-D pelvis reconstruction and subsequent automatic cup planning. Two different planning strategies were applied and evaluated with clinical data. Two different cup planning methods were investigated: The first planning strategy is based on a combined pelvis and cup statistical atlas. Thereby, the pelvis part of the combined atlas is matched to the reconstructed pelvis model, resulting in an optimized cup planning. The second planning strategy analyzes the morphology of the reconstructed pelvis model to determine the best fitting cup implant. The first planning strategy was compared to 3-D CT-based planning. Digitally reconstructed radiographs of THA patients with differently severe pathologies were used to evaluate the accuracy of predicting the cup size and position. Within a discrepancy of one cup size, the size was correctly identified in 100% of the cases for Crowe type I datasets and in 77.8% of the cases for Crowe type II, III, and IV datasets. The second planning strategy was analyzed with respect to the eventually implanted cup size. In seven patients, the estimated cup diameter was correct within one cup size, while the estimation for the remaining five patients differed by two cup sizes. While both planning strategies showed the same prediction rate with a discrepancy of one cup size (87.5%), the prediction of the exact cup size was increased for the statistical atlas-based strategy (56%) in contrast to the anatomically driven approach (37.5%). The proposed approach demonstrated the clinical validity of using 2-D/3-D reconstruction technique for cup planning.

  1. The effect of intraoral suction on oxygen-enriched surgical environments: a mechanism for reducing the risk of surgical fires.

    Science.gov (United States)

    VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Vinson, LaQuia A

    2014-01-01

    In this study, a mechanical model was applied in order to replicate potential surgical fire conditions in an oxygen-enriched environment with and without high-volume suction typical for dental surgical applications. During 41 trials, 3 combustion events were measured: an audible pop, a visible flash of light, and full ignition. In at least 11 of 21 trials without suction, all 3 conditions were observed, sometimes with an extent of fire that required early termination of the experimental trial. By contrast, in 18 of 20 with-suction trials, ignition did not occur at all, and in the 2 cases where ignition did occur, the fire was qualitatively a much smaller, candle-like flame. Statistically comparing these 3 combustion events in the no-suction versus with-suction trials, ignition (P = .0005), audible pop (P = .0211), and flash (P = .0092) were all significantly more likely in the no-suction condition. These results suggest a possible significant and new element to be added to existing surgical fire safety protocols toward making surgical fires the "never-events" they should be.

  2. [Clinical observation of post-herpetic neuralgia treated with TCM herbal cupping therapy].

    Science.gov (United States)

    Wu, Xi; Hu, Hui; Guo, Liang; Wang, Hui

    2013-02-01

    To compare the difference in the efficacy on post-herpetic neuralgia among TCM herbal cupping therapy, Chinese medicine thermal compressing therapy and mecobalamine. Fifty-seven cases were randomized into a TCM herbal cupping group, a thermal compressing group and a western medicine group, 19 cases in each one. The oral administration of ibuprofen was applied in every group. In the herbal cupping group, the bamboo cups soaked in the boiled Chinese herbal decoction were sucked on the most significant painful area. In the thermal compressing group, the towel soaked in the boiled Chinese herbal decoction was compressed on the most significant painful area. In the medication group, the muscular injection of mecobalamine was adopted. The treatment was given once a day, for 2 weeks totally in each group. SF-MPQ score and clinical efficacy before and after treatment were observed in each group. The remarkable effective rates were 78.9% (15/19), 36.8% (7/19) and 5.3% (1/19) in the TCM herbal cupping group, thermal compressing group and western medicine group separately. The efficacy in the TCM herbal cupping group was significantly superior to the thermal compressing group and western medicine group (all P cupping group was reduced more significantly as compared with the thermal compressing group and western medicine group (all P cupping therapy achieves the superior efficacy for post-herpetic neuralgia and relieves pain effectively of the patients, which is more advantageous than CM herbal thermal compressing therapy and Mecobalamine.

  3. Endoscopic en bloc resection of an exophytic gastrointestinal stromal tumor with suction excavation technique

    Science.gov (United States)

    Choi, Hyuk Soon; Chun, Hoon Jai; Kim, Kyoung-Oh; Kim, Eun Sun; Keum, Bora; Jeen, Yoon-Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Here, we report the first successful endoscopic resection of an exophytic gastrointestinal stromal tumor (GIST) using a novel perforation-free suction excavation technique. A 49-year-old woman presented for further management of a gastric subepithelial tumor on the lesser curvature of the lower body, originally detected via routine upper gastrointestinal endoscopy. Abdominal computed tomography and endoscopic ultrasound showed a 4-cm extraluminally protruding mass originating from the muscularis propria layer. The patient firmly refused surgical resection owing to potential cardiac problems, and informed consent was obtained for endoscopic removal. Careful dissection and suction of the tumor was repeated until successful extraction was achieved without serosal injury. We named this procedure the suction excavation technique. The tumor’s dimensions were 3.5 cm × 2.8 cm × 2.5 cm. The tumor was positive for C-KIT and CD34 by immunohistochemical staining. The mitotic count was 6/50 high-power fields. The patient was followed for 5 years without tumor recurrence. This case demonstrated the use of endoscopic resection of an exophytic GIST using the suction excavation technique as a potential therapy without surgical resection. PMID:27340363

  4. Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

    Science.gov (United States)

    Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki

    2010-04-01

    Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  5. Theoretical Analysis of Effects of Wall Suction on Entropy Generation Rate in Laminar Condensate Layer on Horizontal Tube

    Directory of Open Access Journals (Sweden)

    Tong-Bou Chang

    2014-01-01

    Full Text Available The effects of wall suction on the entropy generation rate in a two-dimensional steady film condensation flow on a horizontal tube are investigated theoretically. In analyzing the liquid flow, the effects of both the gravitational force and the viscous force are taken into account. In addition, a film thickness reduction ratio, Sf, is introduced to evaluate the effect of wall suction on the thickness of the condensate layer. The analytical results show that, the entropy generation rate depends on the Jakob number Ja, the Rayleigh number Ra, the Brinkman number Br, the dimensionless temperature difference ψ, and the wall suction parameter Sw. In addition, it is shown that in the absence of wall suction, a closed-form correlation for the Nusselt number can be derived. Finally, it is shown that the dimensionless entropy generation due to heat transfer, NT, increases with an increasing suction parameter Sw, whereas the dimensionless entropy generation due to liquid film flow friction, NF, decreases.

  6. LES-based characterization of a suction and oscillatory blowing fluidic actuator

    Science.gov (United States)

    Kim, Jeonglae; Moin, Parviz

    2015-11-01

    Recently, a novel fluidic actuator using steady suction and oscillatory blowing was developed for control of turbulent flows. The suction and oscillatory blowing (SaOB) actuator combines steady suction and pulsed oscillatory blowing into a single device. The actuation is based upon a self-sustained mechanism of confined jets and does not require any moving parts. The control output is determined by a pressure source and the geometric details, and no additional input is needed. While its basic mechanisms have been investigated to some extent, detailed characteristics of internal turbulent flows are not well understood. In this study, internal flows of the SaOB actuator are simulated using large-eddy simulation (LES). Flow characteristics within the actuator are described in detail for a better understanding of the physical mechanisms and improving the actuator design. LES predicts the self-sustained oscillations of the turbulent jet. Switching frequency, maximum velocity at the actuator outlets, and wall pressure distribution are in good agreement with the experimental measurements. The computational results are used to develop simplified boundary conditions for numerical experiments of active flow control. Supported by the Boeing company.

  7. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    Science.gov (United States)

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (Pcup coverage (Pearson r=0.761, Pcup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  8. GPU-powered model analysis with PySB/cupSODA.

    Science.gov (United States)

    Harris, Leonard A; Nobile, Marco S; Pino, James C; Lubbock, Alexander L R; Besozzi, Daniela; Mauri, Giancarlo; Cazzaniga, Paolo; Lopez, Carlos F

    2017-11-01

    A major barrier to the practical utilization of large, complex models of biochemical systems is the lack of open-source computational tools to evaluate model behaviors over high-dimensional parameter spaces. This is due to the high computational expense of performing thousands to millions of model simulations required for statistical analysis. To address this need, we have implemented a user-friendly interface between cupSODA, a GPU-powered kinetic simulator, and PySB, a Python-based modeling and simulation framework. For three example models of varying size, we show that for large numbers of simulations PySB/cupSODA achieves order-of-magnitude speedups relative to a CPU-based ordinary differential equation integrator. The PySB/cupSODA interface has been integrated into the PySB modeling framework (version 1.4.0), which can be installed from the Python Package Index (PyPI) using a Python package manager such as pip. cupSODA source code and precompiled binaries (Linux, Mac OS/X, Windows) are available at github.com/aresio/cupSODA (requires an Nvidia GPU; developer.nvidia.com/cuda-gpus). Additional information about PySB is available at pysb.org. paolo.cazzaniga@unibg.it or c.lopez@vanderbilt.edu. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  9. The application of suction caisson technology to offshore wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    A mathematical model describing the behaviour of caisson foundations for offshore wind turbines has been developed. The model has been verified and calibrated through laboratory and field work. Simultaneously, conceptual designs of wind turbine foundations incorporating suction caissons were studied using the same model. It was concluded that much of the seabed around Britain is well suited to the use of caissons and monopod and quadropod structures are superior to tripods. Although suction caissons are vulnerable to scour, rock dumping can largely eliminate this potential problem. The next phase will be to install a fully instrumented full-scale prototype to monitor the effects of wind and waves. The main contractor was SLP Engineering Limited and about 75 per cent of the funding came from the DTI.

  10. Chronological changes in functional cup position at 10 years after total hip arthroplasty.

    Science.gov (United States)

    Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko

    2017-09-19

    This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.

  11. The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance.

    Directory of Open Access Journals (Sweden)

    Hossein Gholizadeh

    Full Text Available BACKGROUND: The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction and the Dermo (pin/lock suspension systems on amputees' gait performance. METHODOLOGY/PRINCIPAL FINDINGS: Ten unilateral transtibial amputees participated in this prospective study, and two prostheses were fabricated for each of them. A three-dimensional motion analysis system was used to evaluate the temporal-spatial, kinematics and kinetics variables during normal walking. We also asked the participants to complete some part of Prosthesis Evaluation Questionnaire (PEQ regarding their satisfaction and problems with both systems. The results revealed that there was more symmetry in temporal-spatial parameters between the prosthetic and sound limbs using the suction system. However, the difference between two systems was not significant (p<0.05. Evaluation of kinetic data and the subjects' feedback showed that the participants had more confidence using the suction socket and the sockets were more fit for walking. Nevertheless, the participants had more complaints with this system due to the difficulty in donning and doffing. CONCLUSION: It can be concluded that even though the suction socket could create better suspension, fit, and gait performance, overall satisfaction was higher with the pin/lock system due to easy donning and doffing of the prosthesis. TRIAL REGISTRATION: irct.ir IRCT2014012816395N1.

  12. Football business models: Why did Germany win the World Cup?

    DEFF Research Database (Denmark)

    Cortsen, Kenneth

    2016-01-01

    This article looks into the managerial aspects related to why and how Germany won the 2014 FIFA World Cup.......This article looks into the managerial aspects related to why and how Germany won the 2014 FIFA World Cup....

  13. Gene Expression Profiling of the Intact Dermal Sheath Cup of Human Hair Follicles.

    Science.gov (United States)

    Niiyama, Shiro; Ishimatsu-Tsuji, Yumiko; Nakazawa, Yosuke; Yoshida, Yuzo; Soma, Tsutomu; Ideta, Ritsuro; Mukai, Hideki; Kishimoto, Jiro

    2018-04-24

    Cells that constitute the dermal papillae of hair follicles might be derived from the dermal sheath, the peribulbar component of which is the dermal sheath cup. The dermal sheath cup is thought to include the progenitor cells of the dermal papillae and possesses hair inductive potential; however, it has not yet been well characterized. This study investigated the gene expression profile of the intact dermal sheath cup, and identified dermal sheath cup signature genes, including extracellular matrix components and BMP-binding molecules, as well as TGF-b1 as an upstream regulator. Among these, GREM2, a member of the BMP antagonists, was found by in situ hybridization to be highly specific to the dermal sheath cup, implying that GREM2 is a key molecule contributing to maintenance of the properties of the dermal sheath cup.

  14. Fluctuation of Cup Orientation During Press-Fit Insertion: A Possible Cause of Malpositioning.

    Science.gov (United States)

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Sugano, Nobuhiko

    2015-10-01

    We evaluated real-time angular changes during press-fit cup insertion in 70 total hip arthroplasties. Inclination and anteversion cup angles on navigation system were recorded after each procedure of five hammer blows during cup insertion, and maximum deviated inclination (MDI) and anteversion (MDA) angles until the cup was fully seated were measured. We found 1 (1%) and 29 (41%) hips with increases and decreases in MDI of 5° or more, and 13 (19%) and 6 (8%) hips with increases and decreases in MDA of 5° or more, respectively. The MDI in men was significantly lower and the MDA for left-side surgery was significantly higher. Surgeons should pay attention to fluctuation in angular changes during cup insertion and may consider countermeasures to minimize cup malpositioning. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Numerical Study of Piping Limits for Suction Installation of Offshore Skirted Foundations an Anchors in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C. L.

    2010-01-01

    Skirted foundations and anchors have proved to be competitive solutions for various types of fixed offshore platforms, subsea systems and an attractive foundation alternative for offshore wind turbines. One main design challenge for skirted structures in sand is to penetrate the skirted deep enough...... to obtain the required capacity. In order to overcome the high penetration resistance in sand suction assisted penetration is needed. Suction installation may cause the formation of piping channels, which break down the hydraulic seal and prevent further installation. This paper presents a numerical study...... of failure limits during suction installation in respect to both homogenous and layered soil profile. A numerical flow analysis is performed to determine the hydraulic gradients developing in response to the suction applied, and the results are presented as simple closed form solutions useful for evaluation...

  16. Is Cup Positioning Challenged in Hips Previously Treated With Periacetabular Osteotomy?

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Stilling, Maiken; Søballe, Kjeld

    2014-01-01

    After periacetabular osteotomy (PAO), some patients develop osteoarthritis with need of a total hip arthroplasty (THA). We evaluated the outcome of THA following PAO and explored factors associated with inferior cup position and increased polyethylene wear. Follow-up were performed 4 to 10years...... after THA in 34 patients (38 hips) with previous PAO. Computer analysis evaluated cup position and wear rates. No patient had dislocations or revision surgery. Median scores were: Harris hip 96, Oxford hip 38 and WOMAC 78. Mean cup anteversion and abduction angles were 22(o) (range 7°-43°) and 45......° (range 28°-65°). Outliers of cup abduction were associated with persisting dysplasia (CE...

  17. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    OpenAIRE

    Hirokazu Takai, MD; Tomoki Takahashi, MD, PhD

    2017-01-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used ...

  18. Reduction of the suction losses through reed valves in hermetic reciprocating compressors using a magnet coil

    Science.gov (United States)

    Hopfgartner, J.; Posch, S.; Zuber, B.; Almbauer, R.; Krischan, K.; Stangl, S.

    2017-08-01

    Reed valves are widely used in hermetic reciprocating compressors and are responsible for a large part of the thermodynamic losses. Especially, the suction valve, which is opened nearly during the whole suction stroke, has a big potential for improvement. Usually, suction valves are opened only by vacuum created by the moving piston and should be closed before the compression stroke starts to avoid a reversed mass-flow through the valve. Therefore, the valves are prestressed, which results on the other hand in a higher flow resistance. In this work, a suction valve is investigated, which is not closed by the preload of the valve but by an electromagnetic coil located in the suction muffler neck. Shortly before the piston reaches its bottom dead centre, voltage is applied to the coil and a magnetic force is generated which pulls the valve shut. Thereby, the flow resistance through the valve can be reduced by changing the preload on the reed valve because it is no longer needed to close the valve. The investigation of this adapted valve and the electromagnetic coil is firstly done by numerical simulations including fluid structure interactions of the reed valves of a reciprocating compressor and secondly by experiments made on a calorimeter test bench.

  19. Influence of saturation degree and role of suction in unsaturated soils behaviour: application to liquefaction

    Directory of Open Access Journals (Sweden)

    Vernay Mathilde

    2016-01-01

    Full Text Available The effect of the pore fluid compressibility on liquefaction has been studied by various authors. But few papers have been published about the role of suction in cyclic behavior of unsaturated soils. Most of these works use Skempton coefficient B as a reference in terms of saturation degree to analyze their results. The use of B in experimental conditions is convenient, but is not accurate when studying liquefaction behavior, since effects of suction are neglected. In this paper, the influence of saturation degree on mechanical behavior of a soil under dynamic loads is studied. Cyclic undrained triaxial tests were performed on sand samples, under various levels of saturation. Soil-water characteristic curve was used, in order to study influence of suction. The first results confirm that when the degree of saturation decreases, the resistance increases. Initial positive suction tends to stiffen the soil. It also appears that the presence of air delays the occurrence of liquefaction, but doesn’t prevent it. Indeed, liquefaction is observed, whether the soil is saturated or not.

  20. Performance analysis of small-scale experimental facility of TWDEC

    International Nuclear Information System (INIS)

    Kawana, Ryoh; Ishikawa, Motoo; Takeno, Hiromasa; Yamamoto, Takayoshi; Yasaka, Yasuyoshi

    2008-01-01

    The objective of the present paper is to analyze small-scale experimental facilities of TWDEC (Travelling Wave type Direct Energy Converter) and to propose a modification in regard to a measuring device of the facilities by means of numerical simulation with the axisymmetrical two-dimensional approximation (a PIC method). The numerical simulation has given the following results: (1) tendency of the numerical results agree with the experimental results on the measured deceleration efficiency, (2) the deceleration efficiency measured in the experiment will increase if the radius of Faraday cup installed in the experiment increases and (3) the wave of condensation and rarefaction of measured electric charge density, which is averaged in the r-direction below the radius of Faraday cup, is not formed enough with a small radius of Faraday cup because of the r component of electric field which is induced by the electrode geometry

  1. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    International Nuclear Information System (INIS)

    Zou, Zhichao; Wang, Fujun; Yao, Zhifeng; Tao, Ran; Xiao, Ruofu; Li, Huaicheng

    2016-01-01

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t_0) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t_0, the radial force is small (approaching zero). At 0.4–1.4t_0, the radial force increases rapidly. After 1.4t_0, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research provides a scientific

  2. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhichao [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Wang, Fujun, E-mail: wangfj@cau.edu.cn [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Yao, Zhifeng [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Tao, Ran [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Xiao, Ruofu [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Li, Huaicheng [Shanghai Liancheng (Group) Co., Ltd., Shanghai 201812 (China)

    2016-12-15

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t{sub 0}) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t{sub 0}, the radial force is small (approaching zero). At 0.4–1.4t{sub 0}, the radial force increases rapidly. After 1.4t{sub 0}, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research

  3. Gravity separation of pericardial fat in cardiotomy suction blood: an in vitro model.

    Science.gov (United States)

    Kinard, M Rhett; Shackelford, Anthony G; Sistino, Joseph J

    2009-06-01

    Fat emboli generated during cardiac surgery have been shown to cause neurologic complications in patients postoperatively. Cardiotomy suction has been known to be a large generator of emboli. This study will examine the efficacy of a separation technique in which the cardiotomy suction blood is stored in a cardiotomy reservoir for various time intervals to allow spontaneous separation of fat from blood by density. Soybean oil was added to heparinized porcine blood to simulate the blood of a patient with hypertriglyceridemia (> 150 mg/dL). Roller pump suction was used to transfer the room temperature blood into the cardiotomy reservoir. Blood was removed from the reservoir in 200-mL aliquots at 0, 15, 30 45, and 60 minutes. Samples were taken at each interval and centrifuged to facilitate further separation of liquid fat. Fat content in each sample was determined by a point-of-care triglyceride analyzer. Three trials were conducted for a total of 30 samples. The 0-minute group was considered a baseline and was compared to the other four times. Fat concentration was reduced significantly in the 45- and 60-minute groups compared to the 0-, 15-, and 30-minute groups (p Gravity separation of cardiotomy suction blood is effective; however, it may require retention of blood for more time than is clinically acceptable during a routing coronary artery bypass graft surgery.

  4. The Sorption Behavior of Wood Studied by Means of an Improved Cup Method

    DEFF Research Database (Denmark)

    Eitelberger, Johannes; Svensson, Staffan

    2012-01-01

    background of transport processes, a special experimental test setup—the improved cup method—is presented. It allows for separation of sorption from other processes. In this test, a diffusion cup contains a thin specimen of wood, with one side facing outwards to a climate chamber and the opposite side facing...... inwards the cup. In contrast to the common cup method, the herein presented method uses a data logger for relative humidity and temperature placed inside the cup. The use of thin cross-cut specimens allows for explicit separation of the different processes occurring during transient moisture transport....... Mass changes were determined and relative humidity inside the cups was measured for eight specimens of Norway spruce with different specimen thicknesses. Relative humidity was increased in three uniform steps in the test chamber from 4.0 up to 76.5%. The results obtained with this special test setup...

  5. Development of advanced stability theory suction prediction techniques for laminar flow control. [on swept wings

    Science.gov (United States)

    Srokowski, A. J.

    1978-01-01

    The problem of obtaining accurate estimates of suction requirements on swept laminar flow control wings was discussed. A fast accurate computer code developed to predict suction requirements by integrating disturbance amplification rates was described. Assumptions and approximations used in the present computer code are examined in light of flow conditions on the swept wing which may limit their validity.

  6. A Report on Deliverable Three: Determine a Standard Performance Test for Military Suction Device Use

    Science.gov (United States)

    2017-09-20

    evaluating device suction while either wetted or completely immersed is highly important to predict performance in battlefield scenarios. Summary...mechanical, electrical, and environmental. OBJECTIVE: Research and review current test methods outlined in ISO 10079 and published journal articles...of contemporary oropharyngeal suction. The American journal of emergency medicine 17, 611- 613 (1999). 4. Hodgetts, T., Mahoney, P., Evans, G

  7. Importance of nuclear medicine diagnostics in CUP syndrome

    International Nuclear Information System (INIS)

    Winter, M.C.; Haberkorn, U.; Kratochwil, C.

    2014-01-01

    The diagnostic work-up in patients with carcinoma of unknown primary (CUP) syndrome is extensive, highly time-consuming and cost-intensive and ultimately often fails to detect a primary site. In this context chest X-ray and computed tomography (CT) have been used as standard imaging modalities in CUP syndrome. Since the introduction of positron emission tomography (PET) evaluation of tumor vitality has become possible. Furthermore, PET-CT hybrid scanners allow the combination of functional and morphological imaging. Several meta-analyses have reported an additional overall detection rate between 24.5 % and 44 % by either PET or PET-CT. Metastatic localization (cervical versus extracervical) did not influence the performance. The sensitivity was usually high (> 80 %) but specificity was moderate ranging from 68 % to 88 % at best. If mentioned, the results obtained by fluorodeoxyglucose (FDG)-PET significantly changed the clinical management in approximately one third of the patients studied. In a direct comparison with PET alone, PET-CT did not depict significantly more primary tumors but was able to reduce false positive findings. To determine the real additional value of PET-CT in the diagnosis of CUP syndrome large prospective studies with more uniform inclusion criteria are needed. Despite the capabilities of FDG-PET-CT there is as yet no evidence that a potentially improved diagnostic algorithm is translated into a better patient outcome. Nevertheless, FDG-PET-CT should be performed in all CUP patients where conventional imaging failed to detect a primary site or the results are equivocal. In CUP patients with cervical lymph node metastases PET-CT should be carried out prior to panendoscopy to reduce the number of false negative biopsies. (orig.) [de

  8. The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.

    Science.gov (United States)

    Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce

    2013-01-01

    Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.

  9. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

    International Nuclear Information System (INIS)

    Hu Jing; Rovey, Joshua L.

    2011-01-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

  10. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization.

    Science.gov (United States)

    Hu, Jing; Rovey, Joshua L

    2011-07-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a "double-humped" energy distribution.

  11. HIE-ISOLDE Faraday cups tested with ion beams at TRIUMF

    CERN Document Server

    Cantero, E D

    2014-01-01

    The future HIE-ISOLDE Faraday cups for both the intercryomodule regions and the HEBTs have been tested using 34S+7, 4He+, 23Na+6 and 20Ne+5 beams from the ISAC-II accelerator at TRIUMF. Their performance has been characterized together with the Faraday cups from REX-ISOLDE and those from ISAC-II. The measurements were done at E/A = 1.5, 2.85 and 5.5 MeV/u, with beam intensities in the range of 100 pA to 4 nA. The performance of these Faraday cups has been compared under the same beam conditions for different bias voltages up to -350 V. Within the experimental uncertainties, most of them coming from fluctuations in beam intensity, all devices showed similar results. Biasing the Faraday cup repeller ring to voltages of at least -60 V, the escape of secondary electrons was suppressed.

  12. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    Directory of Open Access Journals (Sweden)

    Turke Shawaf

    2018-05-01

    Full Text Available Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml size with narrow mouths were used. A manual pump (sucking cups was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusion: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  13. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    Science.gov (United States)

    Shawaf, Turke; El-Deeb, Wael; Hussen, Jamal; Hendi, Mahmoud; Al-Bulushi, Shahab

    2018-01-01

    Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama) on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml) size with narrow mouths were used. A manual pump (sucking cups) was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusions: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  14. Tool for cutting locking cups from guide tube mounting screws in a nuclear reactor

    International Nuclear Information System (INIS)

    Nee, J.D.; Hahn, J.J.

    1987-01-01

    This patent describes an apparatus for freeing a socket-head screw from a locking cup therefor in a reactor cavity, wherein the locking cup includes a fixed cylindrical side wall encircling the side surface of the screw head and an annular end wall overlying the outer end surface of the screw head. The apparatus consists of: frame means, cylindrical cutter means having a longitudinal axis and having a frustoconical cutting surface with an inner diameter less than the inner diameter of the locking cup side wall and with an outer diameter greater than the outer diameter of the locking cup side wall, and drive means carried by the frame means and coupled to the cutter means for effecting rotation thereof about the axis, the rotating cutter means are operable for severing the locking cup end wall from the locking cup side wall at the junction therebetween when the cutter means is moved against the locking cup substantially coaxially therewith

  15. Deriving the suction stress of unsaturated soils from water retention curve, based on wetted surface area in pores

    Science.gov (United States)

    Greco, Roberto; Gargano, Rudy

    2016-04-01

    The evaluation of suction stress in unsaturated soils has important implications in several practical applications. Suction stress affects soil aggregate stability and soil erosion. Furthermore, the equilibrium of shallow unsaturated soil deposits along steep slopes is often possible only thanks to the contribution of suction to soil effective stress. Experimental evidence, as well as theoretical arguments, shows that suction stress is a nonlinear function of matric suction. The relationship expressing the dependence of suction stress on soil matric suction is usually indicated as Soil Stress Characteristic Curve (SSCC). In this study, a novel equation for the evaluation of the suction stress of an unsaturated soil is proposed, assuming that the exchange of stress between soil water and solid particles occurs only through the part of the surface of the solid particles which is in direct contact with water. The proposed equation, based only upon geometric considerations related to soil pore-size distribution, allows to easily derive the SSCC from the water retention curve (SWRC), with the assignment of two additional parameters. The first parameter, representing the projection of the external surface area of the soil over a generic plane surface, can be reasonably estimated from the residual water content of the soil. The second parameter, indicated as H0, is the water potential, below which adsorption significantly contributes to water retention. For the experimental verification of the proposed approach such a parameter is considered as a fitting parameter. The proposed equation is applied to the interpretation of suction stress experimental data, taken from the literature, spanning over a wide range of soil textures. The obtained results show that in all cases the proposed relationships closely reproduces the experimental data, performing better than other currently used expressions. The obtained results also show that the adopted values of the parameter H0

  16. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    Directory of Open Access Journals (Sweden)

    Ahmed Almazroa

    2015-01-01

    Full Text Available Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed.

  17. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    Science.gov (United States)

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  18. Cup Blocks the Precocious Activation of the Orb Autoregulatory Loop

    Science.gov (United States)

    Wong, Li Chin; Schedl, Paul

    2011-01-01

    Translational regulation of localized mRNAs is essential for patterning and axes determination in many organisms. In the Drosophila ovary, the germline-specific Orb protein mediates the translational activation of a variety of mRNAs localized in the oocyte. One of the Orb target mRNAs is orb itself, and this autoregulatory activity ensures that Orb proteins specifically accumulate in the developing oocyte. Orb is an RNA-binding protein and is a member of the cytoplasmic polyadenylation element binding (CPEB) protein family. We report here that Cup forms a complex in vivo with Orb. We also show that cup negatively regulates orb and is required to block the precocious activation of the orb positive autoregulatory loop. In cup mutant ovaries, high levels of Orb accumulate in the nurse cells, leading to what appears to be a failure in oocyte specification as a number of oocyte markers inappropriately accumulate in nurse cells. In addition, while orb mRNA is mislocalized and destabilized, a longer poly(A) tail is maintained than in wild type ovaries. Analysis of Orb phosphoisoforms reveals that loss of cup leads to the accumulation of hyperphosphorylated Orb, suggesting that an important function of cup in orb-dependent mRNA localization pathways is to impede Orb activation. PMID:22164257

  19. Experimental study on occurrence-time ratio measurements of air entrainment in a suction sump

    International Nuclear Information System (INIS)

    Inagaki, K; Funaki, J; Hirata, K

    2009-01-01

    In order to get accurate measurements of air entrainment in a suction sump, we design some new simple bubble sensors, which can detect the existence of air bubbles inside a suction pipe with no disturbances by the sensors and with a fine spatial resolution. We force on an intermittency factor γ, that is, an occurrence-time ratio of the air entrainment, and compare the result by the present sensor with those by conventional two methods; namely, visual and auditory ones. As a result, we show the criteria which specify lower-accuracy conditions in the conventional methods. By the visual method, the accuracy of the γ becomes low, when γ is less than 0.05. By the auditory method, the accuracy of γ becomes low, when the submergence depth S of the suction pipe is close to the critical one S c .

  20. Burns induced by cupping therapy in a burn center in northeast china.

    Science.gov (United States)

    Jing-Chun, Zhao; Jia-Ao, Yu; Chun-Jing, Xian; Kai, Shi; Lai-Jin, Lu

    2014-07-01

    Cupping therapy as a curative skill has been developed and applied throughout history. Despite reports of adverse effects, this therapy is considered to be relatively safe with no systemic reviews documenting negative side effects. The aim of this study was to explore methods that avoid the adverse effects sometimes associated with this therapy. Clinical records of 14 outpatients and inpatients that visited the First Hospital of Jilin University (Changchun, China) for management of burn injuries caused by cupping therapy were retrospectively reviewed. Characteristics, history of injury, and treatment of each patient was collected and analyzed. Burn injury induced by cupping therapy was not uncommon. Most of the injuries were mild to moderate and cured by conservative methods without severe complications. The use of wet cupping was more prevalent among injured patients than dry cupping. Cupping therapy as an ancient alternative treatment is still popular with a large number of devoted practitioners. Although there is the potential for injury during the application of this therapy, this is mostly preventable. Standardized training for health care professionals and increased the awareness among the public about the proper methods to administer this therapy to avoid adverse effects is important.

  1. Management of knee osteoarthritis with cupping therapy.

    Science.gov (United States)

    Khan, Asim Ali; Jahangir, Umar; Urooj, Shaista

    2013-10-01

    The study aimed to evaluate the effect of cupping therapy at a clinical setting for knee osteoarthritis. A randomized, controlled clinical trial was conducted. Cupping was performed on 0-6(th) day; 9-11(th) day and 14(th) day, i.e., 11 sittings follow-up to determine longer term carryover of treatment effects utilizing both objective and subjective assessment. The assessment was performed before and after treatment spreading over a period of 15 days. The results of this study shows significant and better results in the overall management of knee osteoarthritis, particularly in relieving pain, edema, stiffness and disability. The efficacy of treatment with cupping therapy in relieving signs and symptoms of knee osteoarthritis is comparable to that of acetaminophen 650 mg thrice a day orally, in terms of analgesia, anti-inflammatory and resolution of edema with minimal and temporary side-effects like echymosis and blister formation while as control drug has greater side-effects particularly on upper gastrointestinal tract. It is recommended that further studies are conducted with a larger study samples and of longer duration.

  2. Management of knee osteoarthritis with cupping therapy

    Directory of Open Access Journals (Sweden)

    Asim Ali Khan

    2013-01-01

    Full Text Available The study aimed to evaluate the effect of cupping therapy at a clinical setting for knee osteoarthritis. A randomized, controlled clinical trial was conducted. Cupping was performed on 0-6 th day; 9-11 th day and 14 th day, i.e., 11 sittings follow-up to determine longer term carryover of treatment effects utilizing both objective and subjective assessment. The assessment was performed before and after treatment spreading over a period of 15 days. The results of this study shows significant and better results in the overall management of knee osteoarthritis, particularly in relieving pain, edema, stiffness and disability. The efficacy of treatment with cupping therapy in relieving signs and symptoms of knee osteoarthritis is comparable to that of acetaminophen 650 mg thrice a day orally, in terms of analgesia, anti-inflammatory and resolution of edema with minimal and temporary side-effects like echymosis and blister formation while as control drug has greater side-effects particularly on upper gastrointestinal tract. It is recommended that further studies are conducted with a larger study samples and of longer duration.

  3. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

    Science.gov (United States)

    Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John

    2008-08-01

    Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.

  4. [Analysis on the adverse events of cupping therapy in the application].

    Science.gov (United States)

    Zhou, Xin; Ruan, Jing-wen; Xing, Bing-feng

    2014-10-01

    The deep analysis has been done on the cases of adverse events and common injury of cupping therapy encountered in recent years in terms of manipulation and patient's constitution. The adverse events of cupping therapy are commonly caused by improper manipulation of medical practitioners, ignoring contraindication and patient's constitution. Clinical practitioners should use cupping therapy cautiously, follow strictly the rules of standard manipulation and medical core system, pay attention to the contraindication and take strict precautions against the occurrence of adverse events.

  5. Improved Suction Technique for the Characterization of Construction Materials

    DEFF Research Database (Denmark)

    Thygesen, Lisbeth Garbrecht; Hansen, Kurt Kielsgaard

    2007-01-01

    The suction technique is a method from soil science that is used for the study of moisture storage capacity in porous construction materials at high relative humidity levels (above approximately 93%). The samples to be studied are placed in a pressurized container (an extractor) on a water...

  6. Compilation of LLNL CUP-2 Data

    Energy Technology Data Exchange (ETDEWEB)

    Eppich, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kips, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lindvall, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-07-31

    The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results

  7. Co-ordination of NDH and Cup proteins in CO2 uptake in cyanobacterium Synechocystis sp. PCC 6803.

    Science.gov (United States)

    Han, Xunling; Sun, Nan; Xu, Min; Mi, Hualing

    2017-06-01

    High and low affinity CO2-uptake systems containing CupA (NDH-1MS) and CupB (NDH-1MS'), respectively, have been identified in Synechocystis sp. PCC 6803, but it is yet unknown how the complexes function in CO2 uptake. In this work, we found that deletion of cupB significantly lowered the growth of cells, and deletion of both cupA and cupB seriously suppressed the growth below pH 7.0 even under 3% CO2. The rate of photosynthetic oxygen evolution was decreased slightly by deletion of cupA but significantly by deletion of cupB and more severely by deletion of both cupA and cupB, especially in response to changed pH conditions under 3% CO2. Furthermore, we found that assembly of CupB into NDH-1MS' was dependent on NdhD4 and NdhF4. NDH-1MS' was not affected in the NDH-1MS-degradation mutant and NDH-1MS was not affected in the NDH-1MS'-degradation mutants, indicating the existence of independent CO2-uptake systems under high CO2 conditions. The light-induced proton gradient across thylakoid membranes was significantly inhibited in ndhD-deletion mutants, suggesting that NdhDs functions in proton pumping. The carbonic anhydrase activity was suppressed partly in the cupA- or cupB-deletion mutant but severely in the mutant with both cupA and cupB deletion, indicating that CupA and CupB function in conversion of CO2 to HCO3-. In turn, deletion of cup genes lowered the transthylakoid membrane proton gradient and deletion of ndhDs decreased the CO2 hydration. Our results suggest that NDH-1M provides an alkaline region to activate Cup proteins involved in CO2 uptake. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  8. Rutting resistance of asphalt mixture with cup lumps modified binder

    Science.gov (United States)

    Shaffie, E.; Hanif, W. M. M. Wan; Arshad, A. K.; Hashim, W.

    2017-11-01

    Rutting is the most common pavement distress in pavement structures which occurs mainly due to several factors such as increasing of traffic volume, climatic conditions and also due to construction design errors. This failure reduced the service life of the pavement, reduced driver safety and increase cost of maintenance. Polymer Modified Binder has been observed for a long time in improving asphalt pavement performance. Research shows that the use of polymer in bituminous mix not only improve the resistance to rutting but also increase the life span of the pavement. This research evaluates the physical properties and rutting performance of dense graded Superpave-designed HMA mix. Two different types of dense graded Superpave HMA mix were developed consists of unmodified binder mix (UMB) and cup lumps rubber (liquid form) modified binder mix (CLMB). Natural rubber polymer modified binder was prepared from addition of 8 percent of cup lumps into binder. Results showed that all the mixes passed the Superpave volumetric properties criteria which indicate that these mixtures were good with respect to durability and flexibility. Furthermore, rutting results from APA rutting test was determined to evaluate the performance of these mixtures. The rutting result of CLMB demonstrates better resistance to rutting than those prepared using UMB mix. Addition of cup lumps rubber in asphalt mixture was found to be significant, where the cup lumps rubber has certainly improves the binder properties and enhanced its rutting resistance due to greater elasticity offered by the cup lumps rubber particles. It shows that the use of cup lumps rubber can significantly reduce the rut depth of asphalt mixture by 41% compared to the minimum rut depth obtained for the UMB mix. Therefore, it can be concluded that the cup lumps rubber is suitable to be used as a modifier to modified binder in order to enhance the properties of the binder and thus improves the performance of asphalt mixes.

  9. ACCUWIND - Methods for classification of cup anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Dahlberg, J.Aa.; Friis Pedersen, T.; Busche, P.

    2006-05-15

    Errors associated with the measurement of wind speed are the major sources of uncertainties in power performance testing of wind turbines. Field comparisons of well-calibrated anemometers show significant and not acceptable difference. The European CLASSCUP project posed the objectives to quantify the errors associated with the use of cup anemometers, and to develop a classification system for quantification of systematic errors of cup anemometers. This classification system has now been implemented in the IEC 61400-12-1 standard on power performance measurements in annex I and J. The classification of cup anemometers requires general external climatic operational ranges to be applied for the analysis of systematic errors. A Class A category classification is connected to reasonably flat sites, and another Class B category is connected to complex terrain, General classification indices are the result of assessment of systematic deviations. The present report focuses on methods that can be applied for assessment of such systematic deviations. A new alternative method for torque coefficient measurements at inclined flow have been developed, which have then been applied and compared to the existing methods developed in the CLASSCUP project and earlier. A number of approaches including the use of two cup anemometer models, two methods of torque coefficient measurement, two angular response measurements, and inclusion and exclusion of influence of friction have been implemented in the classification process in order to assess the robustness of methods. The results of the analysis are presented as classification indices, which are compared and discussed. (au)

  10. RoboCup European Championship: Report of the Amsterdam 2000 event

    NARCIS (Netherlands)

    Groen, F.; van der Hoek, W.; Jonker, P.; Krose, B.; Spoelder, H.J.W.; Stramigioli, S.

    2001-01-01

    The local organizers of the RoboCup European Championship presents a brief, informal overview of this event with the aim to support organizers of future RoboCup events in the organization and coordination of such a rather complex tournament. The objective was to organize a low cost scientific event

  11. Initial stability of a highly porous titanium cup in an acetabular bone defect model.

    Science.gov (United States)

    Yoshimoto, Kensei; Nakashima, Yasuharu; Wakiyama, Miyo; Hara, Daisuke; Nakamura, Akihiro; Iwamoto, Mikio

    2018-04-12

    The purpose of this study was to quantify the initial stability of a highly porous titanium cup using an acetabular bone defect model. The maximum torque of a highly porous titanium cup, with a pore size of 640 μm and porosity of 60%, was measured using rotational and lever-out torque testing and compared to that of a titanium-sprayed cup. The bone models were prepared using a polyurethane foam block and had three levels of bone coverage: 100, 70, and 50%. The highly porous titanium cup demonstrated significantly higher maximum torque than the titanium-sprayed cups in the three levels of bone defects. On rotational torque testing, it was found to be 1.5, 1.3, and 1.3 times stronger than the titanium-sprayed cups with 100, 70 and 50% bone coverage, respectively. Furthermore, it was found to be 2.2, 2.3, and 1.5 times stronger on lever-out testing than the titanium-sprayed cup. No breakage in the porous layers was noted during the testing. This study provides additional evidence of the initial stability of highly porous titanium cup, even in the presence of acetabular bone defects. Copyright © 2018. Published by Elsevier B.V.

  12. Fabrication of Faraday Cup Array for the Measurement of 2-Dimensional Proton Beam Profile

    International Nuclear Information System (INIS)

    Jung, Myunghwan; Kim, Bom Sok; Kim, Kyeryung

    2014-01-01

    It has an advantage of easy-to-use and possible to visually check, immediately; on the other hand, the measurement range is very limited. Another method is using the CCD camera-scintillator device such as p43 phosphor screen or chromox. A variety of faraday cup detectors have been recently introduced. The faraday cup is one of the powerful and popular tools for the measurement of beam current. By using several faraday cups in array geometry, it is possible to observe current distribution. In this study, we developed an external faraday cup array for the measure the beam current and profile at a KOMAC (Korea Multi-purpose Accelerator Complex) beam utilization facility. To measure the beam profile, before fabrication of faraday cup array, we use gafchromic film. By making the faraday cup array we were able to reduce the consumption of Gafchromic film and a more accurate diagnosis of the proton beam is possible. The use of faraday cup array, experiment using the proton beam is more reliable and confident

  13. Flow distortion on boom mounted cup anemometers

    DEFF Research Database (Denmark)

    Lindelöw, Per Jonas Petter; Friis Pedersen, Troels; Gottschall, Julia

    In this report we investigate on wind direction dependent errors in the measurement of the horizontal wind speed by boom mounted cup anemometers. The boom mounting on the studied lattice tower is performed according to IEC standard design rules, yet, larger deviations than predicted by flow models...... are observed. The errors on the measurements are likely caused by an underestimation of the flow distortions around the tower. In this paper an experimental method for deriving a correction formula and an in-field calibration is suggested. The method is based on measurements with two cup anemometers mounted...

  14. Radiotherapeutic concepts in cancer of unknown primary site; Strahlentherapeutische Konzepte beim CUP-Syndrom

    Energy Technology Data Exchange (ETDEWEB)

    Krug, D.; Debus, J.; Sterzing, F. [Universitaetsklinikum Heidelberg, Klinik fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany)

    2014-02-15

    The term cancer of unknown primary (CUP) encompasses a group of entities which differ to a great extent regarding etiology, prognosis and therapeutic management. The aim of the study was an elaboration of the role of radiotherapy in CUP syndrome. Systematic literature search and specification of the available treatment options. Radiotherapy is an integral part of interdisciplinary management approaches for patients with CUP in both curative and palliative situations. Radio-oncological techniques, such as intensity-modulated radiotherapy and stereotactic body radiotherapy increase the therapeutic window. Modern diagnostic modalities from radiology and nuclear medicine are the cornerstone of radiotherapeutic interventions, especially in terms of target volume definition and pretherapeutic staging. In the interdisciplinary setting radiation oncology offers the possibility of curative and often organ preserving approaches in patients with axillary and cervical CUP. In addition, improvement and preservation of quality of life can be achieved in patients with metastatic disease. Radiation oncology is a crucial component of the interdisciplinary management of patients with CUP. Therapeutic decisions in patients with CUP should be made in an interdisciplinary setting. (orig.) [German] Das Cancer-of-unknown-primary(CUP)-Syndrom fasst eine Gruppe von Erkrankungen zusammen, die durch eine ausgepraegte Heterogenitaet hinsichtlich Aetiologie, Therapie und Prognose gepraegt sind. Darstellung der Rolle der Strahlentherapie beim CUP-Syndrom. Systematische Literaturrecherche und Erlaeuterung der Behandlungsoptionen. Die Strahlentherapie ist beim CUP-Syndrom sowohl in adjuvanten und definitiven Therapiekonzepten wie auch in palliativer Intention etabliert. Technisch innovative Verfahren wie die intensitaetsmodulierte Radiotherapie und die stereotaktische Bestrahlung im Koerperstammbereich ermoeglichen eine Vergroesserung der therapeutischen Breite. Eine leistungsfaehige und moderne

  15. The Brazilian World Cup: too hot for soccer?

    Science.gov (United States)

    Lucena, Rebecca Luna; Steinke, Ercília Torres; Pacheco, Christina; Vieira, Lucas Lima; Betancour, Maribel Olaya; Steinke, Valdir Adilson

    2017-12-01

    The main objective of this research was to analyze the climate data for the host cities of the soccer World Cup held in Brazil in June and July 2014. A great deal of criticism was expressed about the Brazilian climate in the national and international press and media in the run-up to the competition, suggesting that the air temperature and relative air humidity would be the main adversaries of the soccer teams, especially those from Europe, during the competition. An analysis of the weather was done at the places and times of each of the 64 matches held. A human thermal comfort index was calculated (discomfort index (DI)) for each of the matches in order to discover the real climatic conditions in the host cities during the 2014 World Cup and their potential influence on the teams and human comfort in general. During the 2014 World Cup, only two matches were played at temperatures above 30 °C, representing a negligible percentage of the total number of matches. The air temperature for over half the matches (53%) was 20-25 °C. The results showed the air temperature and relative humidity data analyzed here both individually and in the form of an index indicate that the World Cup held in Brazil in 2014 did not put any of the players at risk due to extreme heat.

  16. Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

    Science.gov (United States)

    Schwarz, T; Weber, M; Wörner, M; Renkawitz, T; Grifka, J; Craiovan, B

    2017-05-01

    Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs. In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam. Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text

  17. STANDARDIZATION OF CUPPING THERAPY POINTS AND MECHANISM OF ACTION IN THE LIGHT OF SCIENCE

    OpenAIRE

    Dr. Izharul Hasan

    2018-01-01

    Now a day’s cupping therapy is an established therapeutic modality among Indian system of medicine as well as worldwide. Inspite of that, standard operative procedure (SOPs) for cupping therapy is yet to develop. In this paper author comprises the possible indications of cupping therapy along with procedures, application points, safety concerns, historical perspective, surgical operative standards described in traditional system of medicine as well as in the light of science. Cupping may be d...

  18. Radon Sub-slab Suctioning System Integrated in Insulating Layer

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    This poster presents a new radon sub-slab suctioning system. This system makes use of a grid of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground floor slab. For this purpose a new system of prefabricated lightweight elements is introduced...

  19. Alternative Shape of Suction Caisson to Reduce Risk of Buckling under high Pressure

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming technology also referred to as bucket foundations. During operation the bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation the bucket is loaded...... cylindrical monopod foundation made of steel. In this paper, an alternative design/shape of the suction caisson, having a smaller risk of buckling under high pressure is presented. The risk of structural buckling is addressed using numerical methods to determine the buckling pressures of the re...

  20. Socio-economic impacts of the 2010 FIFA World Cup | Hermann ...

    African Journals Online (AJOL)

    Socio-economic impacts of the 2010 FIFA World Cup. ... Literature on the impacts of mega events on tourism is available but limited in number in terms of the impacts of mega events on local residents. This study analyses the post ... Keywords: Mega events, economic impacts, social impacts, World Cup, local community.

  1. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  2. Manipulating Tournaments in Cup and Round Robin Competitions

    OpenAIRE

    Russell, Tyrel; Walsh, Toby

    2009-01-01

    In sports competitions, teams can manipulate the result by, for instance, throwing games. We show that we can decide how to manipulate round robin and cup competitions, two of the most popular types of sporting competitions in polynomial time. In addition, we show that finding the minimal number of games that need to be thrown to manipulate the result can also be determined in polynomial time. Finally, we show that there are several different variations of standard cup competitions where mani...

  3. Solar Probe Cup: Laboratory Performance

    Science.gov (United States)

    Case, A. W.; Kasper, J. C.; Korreck, K. E.; Stevens, M. L.; Larson, D. E.; Wright, K. H., Jr.; Gallagher, D. L.; Whittlesey, P. L.

    2017-12-01

    The Solar Probe Cup (SPC) is a Faraday Cup instrument that will fly on the Paker Solar Probe (PSP) spacecraft, orbiting the Sun at as close as 9.86 solar radii. The SPC instrument is designed to measure the thermal solar wind plasma (protons, alphas, and electrons) that will be encountered throughout its close encounter with the Sun. Due to the solar wind flow being primarily radial, the SPC instrument is pointed directly at the Sun, resulting in an extreme thermal environment that must be tolerated throughout the primary data collection phase. Laboratory testing has been performed over the past 6 months to demonstrate the instrument's performance relative to its requirements, and to characterize the measurements over the expected thermal range. This presentation will demonstrate the performance of the instrument as measured in the lab, describe the operational configurations planned for flight, and discuss the data products that will be created.

  4. PERANAN METODE PENGOBATAN ISLAM CUPPING THERAPY DALAM PENURUNAN KADAR GLUKOSA DARAH

    Directory of Open Access Journals (Sweden)

    Cut Khairunnisa

    2016-06-01

    Full Text Available The Role of Islamic Treatment Method “Cupping Therapy” to Decrease Blood Glucose Levels. Cupping therapy has long been used by most Muslims and it has occupied as prominent position among therapeutic approaches.The proof of medical modern research lately have been supports expediency therapy which recommended by the prophet. Nowdays,many medical experts who know the benefits of cupping therapy in treating diseases. Diabetes melitus is a disease that is directly related to blood glucose levels. According to the International Diabetes Federation (IDF in 2013, there were 382 million people suffer from diabetes melitus worldwide and Indonesia as seventh ranks in the world. This study aims to determine the effect of cupping therapy on blood glucose levels in patients of Klinik Sehat dr. Abdurrahmân Medan in 2014. The Study used pre-experimental method with one group pre-test and post-test without a control group and sample took by randomization with a sample of 32 people. Based on the Wilcoxon test with á = 0.05 obtained p-value = 0.021 that means there were a significant differences in mean blood glucose levels before and after cupping therapy (p-value < á.

  5. Cupping therapy: A prudent remedy for a plethora of medical ailments.

    Science.gov (United States)

    Mehta, Piyush; Dhapte, Vividha

    2015-07-01

    Since ancient times, complementary and alternative medicine (CAM; bǔ chōng yǔ tì dài yī xué) have played an important role in human health and welfare. Many therapeutic approaches in healthcare outside the realm of conventional medicine persist in various parts of the world. There is considerable scientific and commercial potential in CAM, which needs to be explored precisely. Cupping therapy ( bá guàn liáo fǎ), one of the CAM, is practiced across the world. This therapy is believed to act by correcting imbalances in the internal bio field, such as by restoring the flow of "Qi (qì)". Cupping involves applying a heated cup to generate a partial vacuum that mobilizes the blood flow and promotes effective healing. This review outlines various tools and techniques of cupping therapy.

  6. The economic value of the 2010 Soccer World Cup

    Directory of Open Access Journals (Sweden)

    M. Saayman

    2008-12-01

    Full Text Available Purpose: The purpose of this article is to estimate the potential economic value of the 2010 Soccer World Cup for South Africa. Problem investigated: The Soccer World Cup (SWC is regarded as the largest sporting event to be hosted and South Africa is investing billions of Rand in the hosting thereof. Based on this the question that comes to mind is, what is the potential economic value of such an event? Previous research attempts to determine the economic value were limited in their focus on what should be included when economic modelling of events is conducted. Most of these studies were done by consultants on behalf of various government departments and consequently, the results of these attempts are criticised for their over-inflating and overestimations by various other researchers. Methodology: The literature review identified many aspects that need to be taken into account when modelling the economic impact of such an event together with aspects identified in the literature review. Lessons from the 2002 Korea/Japan and 2006 Germany Soccer World Cups were used as premise for our estimations. In this article, Computable General Equilibrium (CGE modelling is used to estimate the potential economic value. Findings: The results showed that the 2010 Soccer World Cup would in all probability have positive impacts on the economy of the country in terms of GDP growth and employment, with possible negative effects that include higher inflation and net export losses. Value of research: The value of this research lies in the approach that was followed firstly, by introducing lessons learned from previous World Cups as well as aspects not taken into consideration previously in economic modelling and secondly, by using CGE modelling in determining the economic value. Conclusion: The hosting of the 2010 Soccer World Cup is a major achievement not only for South Africa, but also for the rest of Africa, especially from a marketing point of view. From an

  7. Characterisation and classification of RISØ P2546 cup anemometer

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    2003-01-01

    The characteristics of the RISØ P2546 cup anemometer were investigated in detail by wind tunnel and laboratory tests. The characteristics include accredited calibration, tilt response measurements for tilt angles between -40° to 40°, gust responsemeasurements at 8m/s and turbulence intensities...... of 10%, 16% and 23%, step response measurements at step wind speeds 3,7, 8, 11,9 and 15,2m/s, measurement of torque characteristics at 8m/s, rotor inertia measurements and measurements of friction ofbearings at temperatures -20°C to 40°C. Characteristics were fitted to a time domain cup anemometer model....... The characteristics were transformed into the CLASSCUP classification scheme, and were related to the cup anemometer requirements in the Danishcertification system and in the IEC 61400-121 Committee Draft....

  8. Characterisation and classification of RISØ P2546 cup anemometer

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    2004-01-01

    The characteristics of the RISØ P2546 cup anemometer were investigated in detail by wind tunnel and laboratory tests. The characteristics include accredited calibration, tilt response measurements for tilt angles between -40° to 40°, gust responsemeasurements at 8m/s and turbulence intensities...... of 10%, 16% and 23%, step response measurements at step wind speeds 3,7, 8, 11,9 and 15,2m/s, measurement of torque characteristics at 8m/s, rotor inertia measurements and measurements of friction ofbearings at temperatures -20°C to 40°C. Characteristics were fitted to a time domain cup anemometer model....... The characteristics were transformed into the CLASSCUP classification scheme, and were related to the cup anemometer requirements in the Danishcertification system and in the IEC 61400-121 Committee Draft....

  9. Faraday cup for electron flux measurements on the microtron MT 25

    International Nuclear Information System (INIS)

    Vognar, M.; Simane, C.; Chvatil, D.

    2001-01-01

    The basic design criteria for construction of an evacuated Faraday cup for precise measurement of 5-25 MeV electron beam currents in air from a microtron are characterized. The homemade Faraday cup is described along with the electronic chain and its incorporation into the measuring beam line. The provisions applied to reduce backward electron escape are outlined. The current range was 10 -5 to 10 -10 A. The diameter of the Al entrance window of the Faraday cup was 1.8 cm, its area was 2.54 cm 2 and thickness 0.1 mm

  10. Radiological and migration results of the DURALOC(R)-cup after two years

    International Nuclear Information System (INIS)

    Juen, F.

    2000-10-01

    In 1997 a study was conduced concerning 69 consecutive patients, all of whom consisted of DURALOC(R) series 100 acetabular components. The clinical, radiological and migrational aspect of each component was investigated 2 and 4 years postoperatively. In addition to this, a further 92 cups were analyzed in an identical manner, again 2 years after implantation. This therefore equated to a total of 161 investigated cups after a follow up interval of 2 years. In 144 of these cases the cup was combined with a cementless hydroxyapatite coated Spotorno shaft, with the remaining 17 involving a cemented Link-shaft (Lubinus SP II). A 28 mm Biolox(R) ceramic head was constant in all cases. Clinical data for each cup was collected via completion of a standard examination form, while acetabular migration, both vertical and horizontal, was measured on serial radiographs by the computer assisted EBRA method. From analyses of collected data, it was clearly shown that the clinical results remained very good over the 2- and 4-year-periods however, from radiological evidence it was indicated that for the period 3-4 years postoperatively, an increasing amount of radiolucencies around the cups were apparent. There was clearly no correlation between clinical and migration results. From the data taken from 106 migration curves, the mean total migration over the initial two-year-period was calculated to be 0.88 mm. From analysis of a further 56 migration curves, the mean total migration within 4 years of implantation was assessed to be 1.23 mm, however a decreasing speed of migration over the final 2-year-period was indicated. Our results demonstrate that statements relating to migration results of particular cups are more accurate after four years. However, statements about mean migration values are possible after two years. A migration speed of 1 mm total migration within the first 2 years after operation was predictive for radiological loosening of the cup after four years (p=0

  11. ACCUWIND - Accurate wind speed measurements in wind energy - Summary report[Cup and sonic anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.; Dahlberg, J.Aa.; Cuerva, A.; Mouzakis, F.; Busche, P.; Eecen, P.; Sanz-Andres, A.; Franchini, S.; Markkilde Petersen, S.

    2006-07-15

    The cup anemometer is at present the standard instrument used for mean wind speed measurement in wind energy. It is being applied in high numbers around the world for wind energy assessments. It is also applied exclusively for accredited power performance measurements for certification and verification purposes, and for purposes of optimisation in research and development. The revised IEC standard on power performance measurements has now included requirements for classification of cup anemometers. The basis for setting up such requirements of cup anemometers is two EU projects SITEPARIDEN and CLASSCUP from which the proposed classification method for cup anemometers was developed for the IEC standard. While cup anemometers at present are the standard anemometer being used for average wind speed measurements, sonic anemometers have been developed significantly over the last years, and prices have come down. The application of sonic anemometers may increase in wind energy if they prove to have comparable or better operational characteristics compared to cup anemometers, and if similar requirements to sonic anemometers are established as for cup anemometers. Sonic anemometers have historically been used by meteorologists for turbulence measurements, but have also found a role on wind turbine nacelles for wind speed and yaw control purposes. The report on cup and sonic anemometry deals with establishment of robustness in assessment and classification by focus on methods and procedures for analysis of characteristics of cup and sonic anemometers. The methods and procedures provide a platform, hopefully for use in meeting the requirements of the IEC standard on power performance measurements, as well as for development of improved instruments. (au)

  12. [Clinical application of moving cupping therapy based on skin reaction observation and syndrome differentiation].

    Science.gov (United States)

    Deng, Xiao-Lan; Chen, Bo; Chen, Ze-Lin

    2014-12-01

    The diagnostic evidence on clinical diseases and theoretic basis of moving cupping therapy were ex- plored in the paper. By the observation of the local reaction, such as skin appearance and color, the affected location, duration of sickness and nature of disease were judged. Different moving cupping methods were selected for different disorders. It was discovered that the property of syndromes should be recognized by the palpation on skin and muscle in the moving cupping therapy so that the pathogenesis and treating principle could be carefully determined. The moving cupping therapy is the important component of body surface therapy. Skin reaction observation and syndrome differentiation is the essential guidance of the moving cupping therapy.

  13. A Constitutive Model for Unsaturated soils based on a Compressibility Framework dependent on Suction and Degree of Saturation

    Directory of Open Access Journals (Sweden)

    Sitarenios Panagiotis

    2016-01-01

    Full Text Available The Modified Cam Clay model is extended to account for the behaviour of unsaturated soils using Bishop’s stress. To describe the Loading – Collapse behaviour, the model incorporates a compressibility framework with suction and degree of saturation dependent compression lines. For simplicity, the present paper describes the model in the triaxial stress space with characteristic simulations of constant suction compression and triaxial tests, as well as wetting tests. The model reproduces an evolving post yield compressibility under constant suction compression, and thus, can adequately describe a maximum of collapse.

  14. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Kristensen, L.; Jensen, G.; Hansen, A.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statisticalsignificance of the calibration expressions...

  15. Retinal and anterior eye compartments derive from a common progenitor pool in the avian optic cup

    Science.gov (United States)

    Venters, Sara J.; Cuenca, Paulina D.

    2011-01-01

    Purpose The optic cup is created through invagination of the optic vesicle. The morphogenetic rearrangement creates a double-layered cup, with a hinge (the Optic Cup Lip) where the epithelium bends back upon itself. Shortly after the optic cup forms, it is thought to be sub-divided into separate lineages: i) pigmented epithelium in the outer layer; ii) presumptive iris and ciliary body at the most anterior aspect of the inner layer; and iii) presumptive neural retina in the remainder of the inner layer. We test the native developmental potential of the anterior cup to determine if it normally contributes to the retina. Methods Vital dye and green fluorescent protein (GFP) expressing replication-incompetent retroviral vectors were used to label cells in the nascent optic cup and follow their direct progeny throughout development. Label was applied to either the optic cup lip (n=40), or to the domain just posterior to the lip (n=20). Retroviral labeling is a permanent lineage marker and enabled the analysis of advanced stages of development. Results Labeling within the optic cup gave rise to labeled progeny in the posterior optic cup that differentiated as neural retina (20 of 20). In contrast, labeling cells in the optic cup lip gave rise to progeny of labeled cells arrayed in a linear progression, from the lip into the neural retina (36 of 40). Label was retained in cells at the optic cup lip, regardless of age at examination. In older embryos, labeled progeny delaminated from the optic cup lip to differentiate as muscle of the pupillary margin. Conclusions The data show that the cells at the optic cup lip are a common progenitor population for pigmented epithelium, anterior eye tissues (ciliary body, iris, and pupillary muscle) and retinal neurons. The findings are supportive of an interpretation where the optic cup lip is a specialized niche containing a multipotent progenitor population. PMID:22219630

  16. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    Science.gov (United States)

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  17. Numerical Investigation of Wall Cooling and Suction Effects on Supersonic Flat-Plate Boundary Layer Transition Using Large Eddy Simulation

    Directory of Open Access Journals (Sweden)

    Suozhu Wang

    2015-02-01

    Full Text Available Reducing friction resistance and aerodynamic heating has important engineering significance to improve the performances of super/hypersonic aircraft, so the purpose of transition control and turbulent drag reduction becomes one of the cutting edges in turbulence research. In order to investigate the influences of wall cooling and suction on the transition process and fully developed turbulence, the large eddy simulation of spatially evolving supersonic boundary layer transition over a flat-plate with freestream Mach number 4.5 at different wall temperature and suction intensity is performed in the present work. It is found that the wall cooling and suction are capable of changing the mean velocity profile within the boundary layer and improving the stability of the flow field, thus delaying the onset of the spatial transition process. The transition control will become more effective as the wall temperature decreases, while there is an optimal wall suction intensity under the given conditions. Moreover, the development of large-scale coherent structures can be suppressed effectively via wall cooling, but wall suction has no influence.

  18. Analysis of Infiltration-Suction Response in Unsaturated Residual Soil Slope in Gelugor, Penang

    Science.gov (United States)

    Ashraf Mohamad Ismail, Mohd; Hasliza Hamzah, Nur; Min, Ng Soon; Hazreek Zainal Abidin, Mohd; Tajudin, Saiful Azhar Ahmad; Madun, Aziman

    2018-04-01

    Rainfall infiltration on residual soil slope may impair slope stability by altering the pore-water pressure in the soil. A study has been carried out on unsaturated residual soil slope in Gelugor, Penang to determine the changes in matric suction of residual soils at different depth due to rainwater infiltration. The sequence of this study includes the site investigation, field instrumentation, laboratory experiment and numerical modeling. Void ratio and porosity of soil were found to be decreasing with depth while the bulk density and dry density of soil increased due to lower porosity of soil at greater depth. Soil infiltration rate and matric suction of all depths decrease with the increase of volumetric water content as well as the degree of saturation. Numerical modeling was used to verify and predict the relationship between infiltration-suction response and degree of saturation. Numerical models can be used to integrate the rainfall scenarios into quantitative landslide hazard assessments. Thus, development plans and mitigation measures can be designed for estimated impacts from hazard assessments based on collected data.

  19. CUP-1 Is a Novel Protein Involved in Dietary Cholesterol Uptake in Caenorhabditis elegans

    Science.gov (United States)

    Valdes, Victor J.; Athie, Alejandro; Salinas, Laura S.; Navarro, Rosa E.; Vaca, Luis

    2012-01-01

    Sterols transport and distribution are essential processes in all multicellular organisms. Survival of the nematode Caenorhabditis elegans depends on dietary absorption of sterols present in the environment. However the general mechanisms associated to sterol uptake in nematodes are poorly understood. In the present work we provide evidence showing that a previously uncharacterized transmembrane protein, designated Cholesterol Uptake Protein-1 (CUP-1), is involved in dietary cholesterol uptake in C. elegans. Animals lacking CUP-1 showed hypersensitivity to cholesterol limitation and were unable to uptake cholesterol. A CUP-1-GFP fusion protein colocalized with cholesterol-rich vesicles, endosomes and lysosomes as well as the plasma membrane. Additionally, by FRET imaging, a direct interaction was found between the cholesterol analog DHE and the transmembrane “cholesterol recognition/interaction amino acid consensus” (CRAC) motif present in C. elegans CUP-1. In-silico analysis identified two mammalian homologues of CUP-1. Most interestingly, CRAC motifs are conserved in mammalian CUP-1 homologous. Our results suggest a role of CUP-1 in cholesterol uptake in C. elegans and open up the possibility for the existence of a new class of proteins involved in sterol absorption in mammals. PMID:22479487

  20. 77 FR 28253 - Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI

    Science.gov (United States)

    2012-05-14

    ...-AA00 Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... navigable waters of the East Passage, Narragansett Bay, Rhode Island, during the America's Cup World Series... rulemaking (NPRM) entitled ``Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI...

  1. Frequency Response of Near-Wall Coherent Structures to Localized Periodic Blowing and Suction in Turbulent Boundary Layer

    International Nuclear Information System (INIS)

    Jian-Hua, Liu; Nan, Jiang

    2008-01-01

    We experimentally investigate the frequency response of near-wall coherent structures to localized periodic blowing and suction through a spanwise slot in a turbulent boundary layer by changing the frequency of periodic disturbance at similar velocities of free stream. The effects of blowing and suction disturbance on energy redistribution, turbulent intensity u' rms + , over y + and waveforms of phase-averaged velocity during sweeping process are respectively discussed under three frequencies of periodic blowing and suction in near-wall region of turbulent boundary layer, compared with those in a standard turbulent boundary layer. The most effective disturbance frequency is figured out in this system. (fundamental areas of phenomenology (including applications))

  2. Origin and evolution of cup-shaped structures on leached nuclear waste containment glass surfaces

    International Nuclear Information System (INIS)

    Dubois, C.; Villa, F.; Chambaudet, A.; Vernaz, E.

    1994-01-01

    A three-dimensional surface microanalysis system equipped with a sensitive topographical probe was used to quantify the evolution of cup-shaped structures formed by aqueous leaching of nuclear waste containment glass. A model of the dissolution phenomenon provides satisfactory correlation between calculated and measured cup radius and depth. Dissolution cups form from cracks on the initially cut glass surface. Large cracks control the phenomenon by forming the largest cups, which gradually absorb smaller ones. The evolution of the size and shape of the dissolution cups was described by a model that assumes a constant dissolution rate on the surface, diminishing with crack depth. The best fit with the experimental data was obtained with a dissolution rate one hundred times lower at the bottom of the crack than at the surface. Moreover, it is predictable that all the cups will gradually disappear as they grow larger and flatter over a leaching period of some 2 years, for the glass composition and experimental leaching procedures used in this work

  3. A confirmed case of toxic shock syndrome associated with the use of a menstrual cup.

    Science.gov (United States)

    Mitchell, Michael A; Bisch, Steve; Arntfield, Shannon; Hosseini-Moghaddam, Seyed M

    2015-01-01

    Menstrual cups have been reported to be an acceptable substitute for tampons. These flexible cups have also been reported to provide a sustainable solution to menstrual management, with modest cost savings and no significant health risk. The present article documents the first case of toxic shock syndrome associated with the use of a menstrual cup in a woman 37 years of age, using a menstrual cup for the first time. Toxic shock syndrome and the literature on menstrual cups is reviewed and a possible mechanism for the development of toxic shock syndrome in the patient is described.

  4. Elastoplastic cup model for cement-based materials

    Directory of Open Access Journals (Sweden)

    Yan Zhang

    2010-03-01

    Full Text Available Based on experimental data obtained from triaxial tests and a hydrostatic test, a cup model was formulated. Two plastic mechanisms, respectively a deviatoric shearing and a pore collapse, are taken into account. This model also considers the influence of confining pressure. In this paper, the calibration of the model is detailed and numerical simulations of the main mechanical behavior of cement paste over a large range of stress are described, showing good agreement with experimental results. The case study shows that this cup model has extensive applicability for cement-based materials and other quasi-brittle and high-porosity materials in a complex stress state.

  5. MHD flow over a permeable stretching/shrinking sheet of a nanofluid with suction/injection

    Directory of Open Access Journals (Sweden)

    Sandeep Naramgari

    2016-06-01

    Full Text Available In this study we analyzed the influence of thermal radiation and chemical reaction on two dimensional steady magnetohydrodynamic flow of a nanofluid past a permeable stretching/shrinking sheet in the presence of suction/injection. We considered nanofluid volume fraction on the boundary is submissive controlled, which makes the present study entirely different from earlier studies and physically more realistic. The equations governing the flow are solved numerically. Effects of non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed and presented through graphs. Also, coefficient of skin friction and local Nusselt number is investigated for stretching/shrinking and suction/injection cases separately and presented through tables. Comparisons with existed results are presented. Present results have an excellent agreement with the existed studies under some special assumptions. Results indicate that the enhancement in Brownian motion and thermophoresis parameters depreciates the nanoparticle concentration and increases the mass transfer rate. Dual solutions exist only for certain range of stretching/shrinking and suction/injection parameters.

  6. Soft Robotic Manipulation of Onions and Artichokes in the Food Industry

    Directory of Open Access Journals (Sweden)

    R. Morales

    2014-04-01

    Full Text Available This paper presents the development of a robotic solution for a problem of fast manipulation and handling of onions or artichokes in the food industry. The complete solution consists of a parallel robotic manipulatior, a specially designed end-effector based on a customized vacuum suction cup, and a computer vision software developed for pick and place operations. First, the selection and design process of the proposed robotic solution to fit with the initial requeriments is presented, including the customized vacuum suction cup. Then, the kinematic analysis of the parallel manipulator needed to develop the robot control system is reviewed. Moreover, computer vision application is presented inthe paper. Hardware details of the implementation of the building prototype are also shown. Finally, conclusions and future work show the current status of the project.

  7. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  8. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (FT/ : W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moistur...

  9. Injuries among World Cup ski and snowboard athletes.

    Science.gov (United States)

    Flørenes, T W; Nordsletten, L; Heir, S; Bahr, R

    2012-02-01

    There is little information available on injuries to World Cup skiers and snowboarders. The aim of this study was to describe and compare the injury risk to World Cup athletes in alpine skiing, freestyle skiing, snowboarding, ski jumping, Nordic combined and cross country skiing. We performed retrospective interviews with the International Ski Federation (FIS) World Cup athletes from selected nations during the 2006-2007 and 2007-2008 winter seasons and recorded all acute injuries occurring during the seasons. We interviewed 2121 athletes and recorded 705 injuries. There were 520 (72%) time-loss injuries and 196 (28%) severe injuries (absence >28 days). In freestyle skiing, alpine skiing and snowboarding, there were 27.6, 29.8 and 37.8 time-loss and 14.4, 11.3 and 13.8 severe injuries per 100 athletes per season, respectively. In Nordic combined, ski jumping and cross country skiing, there were 15.8, 13.6 and 6.3 time-loss and 3.3, 5.6 and 0.7 severe injuries per 100 athletes per season, respectively. In conclusion about 1/3 of the World Cup alpine, freestyle and snowboard athletes sustain a time-loss injury each season, while the risk is low in the Nordic disciplines. A particular concern was the high proportion of severe injuries observed among alpine, freestyle and snowboard athletes, which is in contrast to most other sports. © 2010 John Wiley & Sons A/S.

  10. Preparing for the America's Cup: A technological and a human challenge

    KAUST Repository

    Fischer, Martin

    2017-01-17

    The America\\'s Cup is the pinnacle event in sailing and it is the oldest sports trophy in the world. The trophy was originally awarded in 1851 for a race around the Isle of Wight, which was won by the schooner ムAmericaメ. It was subsequently renamed after the yacht and was donated to the New York Yacht Club under the terms of the Deed of Gift, which made the Cup available for perpetual international competition. The 35th America\\'s Cup will be held in May / June 2017 in Bermuda. The races will be sailed in 50-ft foiling catamarans. Instead of a main sail the boats feature a rigid wing. These boats are capable of sailing 3 times the wind speed, with top speeds reaching 45 knots. The lecture describes the technological and human endeavor to develop and prepare the boat and the crew. Developing an America\\'s Cup boat is a multidisciplinary effort. Excellence is required in such different fields as aerodynamics, hydrodynamics, structural analysis, advanced composite engineering and building, design of mechanical control systems, hydraulics, electronics and flight control, to name the most important ones. Since automatic control systems (autopilots) are forbidden in the America\\'s Cup rules there is a strong two-way feedback between sailing practicalities and the technological choices being made. Combine this with the management of a very tight build schedule for hulls, beams, foils, rudders and the wing and you get an idea what it means to prepare for the America\\'s Cup.

  11. 76 FR 39289 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Science.gov (United States)

    2011-07-06

    ...-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI AGENCY: Coast Guard... immediately after the Detroit APBA Gold Cup boat race. This special local regulation will establish... entry found in 33 CFR 100.918, Detroit APBA Gold Cup, Detroit, MI. Currently, the regulations located at...

  12. Safety System for Controlling Fluid Flow into a Suction Line

    Science.gov (United States)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2018-01-01

    A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.

  13. An aerodynamic analysis of recent FIFA world cup balls

    Science.gov (United States)

    Kiratidis, Adrian L.; Leinweber, Derek B.

    2018-05-01

    Drag and lift coefficients of recent FIFA world cup balls are examined. We fit a novel functional form to drag coefficient curves and in the absence of empirical data provide estimates of lift coefficient behaviour via a consideration of the physics of the boundary layer. Differences in both these coefficients for recent balls, which result from surface texture modification, can significantly alter trajectories. Numerical simulations are used to quantify the effect these changes have on the flight paths of various balls. Altitude and temperature variations at recent world cup events are also discussed. We conclude by quantifying the influence these variations have on the three most recent world cup balls, the Brazuca, the Jabulani and the Teamgeist. While our paper presents findings of interest to the professional sports scientist, it remains accessible to students at the undergraduate level.

  14. Characterisation and classification of RISOe P2546 cup anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.

    2003-04-01

    The characteristics of the RISOe P2546 cup anemometer were investigated in detail by wind tunnel and laboratory tests. The characteristics include accredited calibration, tilt response measurements for tilt angles between -40 degC to 40 degC, gust response measurements at 8m/s and turbulence intensities of 10%, 16% and 23%, step response measurements at step wind speeds 3,7, 8, 11,9 and 15,2m/s, measurement of torque characteristics at 8m/s, rotor inertia measurements and measurements of friction of bearings at temperatures -20 degC to 40 degC. Characteristics were fitted to a time domain cup anemometer model. The characteristics were transformed into the CLASSCUP classification scheme, and were related to the cup anemometer requirements in the Danish certification system and in the IEC 61400-121 Committee Draft. (au)

  15. Facility arrangements and the environmental performance of disposable and reusable cups

    NARCIS (Netherlands)

    Potting, José; Harst-Wintraecken, van der Eugenie

    2015-01-01

    Purpose: This paper integrates two complementary life cycle assessment (LCA) studies with the aim to advice facility managers on the sustainable use of cups, either disposable or reusable. Study 1 compares three disposable cups, i.e., made from fossil-based polystyrene (PS), biobased and

  16. EOS-based cup navigation: Randomised controlled trial in 78 total hip arthroplasties.

    Science.gov (United States)

    Verdier, N; Billaud, A; Masquefa, T; Pallaro, J; Fabre, T; Tournier, C

    2016-06-01

    Minimising the risk of cup implantation outside the safe zone is among the objectives of navigation during total hip arthroplasty (THA). However, given the technical challenges raised by navigation when the patient is lying on the side, many surgeons still use the freehand technique. We conducted a randomised controlled trial to evaluate the new navigation system NAVEOS in the iliac plane, which is easily identified in the lateral decubitus position, with the objective of determining whether NAVEOS navigation decreased the frequency of cup implantation outside the safe zone compared to freehand cup positioning, without increasing the operative time or the frequency of complications. NAVEOS navigation decreases the frequency of cup positioning outside the safe zone compared to freehand positioning. This randomised controlled trial compared cup positioning using NAVEOS navigation versus the freehand technique in patients undergoing primary THA. The safe zone was defined according to Lewinnek as 15±10° of radiological anteversion and 40±10° of radiological inclination. Cup position parameters were measured on computed tomography images obtained 3months after THA. The images were read by two independent observers who were blinded to group assignment. The primary evaluation criterion was cup position within the safe zone. A 1:1 randomisation scheme was used to assign 78 patients (mean age, 68years; age range, 44-91years) to NAVEOS navigation or freehand cup positioning. The two groups were comparable for age, gender distribution, body mass index, and preoperative functional scores. In the NAVEOS group, navigation was discontinued prematurely in 6 patients, because of technical difficulties (n=2) or a marked discrepancy with clinical findings (n=4); however, the intention-to-treat approach was used for the analysis. The proportion of cups in the safe zone was 67% (28/39) in the NAVEOS group and 38% (17/39) in the freehand group (P=0.012). Anteversion was within the

  17. AFSC/NMML: Dtag Bristol Bay Beluga Data, May 2011 and August 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Suction cup attached multisensor tags were placed on beluga whales in Bristol Bay, Alaska, to collect depth, 3D acceleration and sound. Data were coupled with...

  18. Vapor pressure lowering effects due to salinity and suction pressure in the depletion of vapor-dominated geothermal reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Battistelli, A. [Aquater S.p.A., Pisa (Italy); Calore, C. [Istituto Internazionale per le Ricerche Geotermiche-CNR, Pisa (Italy); Pruess, K. [Lawrence Berkeley Lab., Berkeley, CA (United States)

    1995-03-01

    The equation-of-state module able to handle saline brines with non-condensible gas, developed for the TOUGH2 simulator, has been improved to include vapor pressure lowering (VPL) due to suction pressure as represented by Kelvin`s equation. In this equation the effects of salt are considered whereas those of non-condensible gas have currently been neglected. Numerical simulations of fluid production from tight matrix blocks have been performed to evaluate the impact of VPL effects due to salinity and suction pressure on the depletion behaviour of vapor-dominated geothermal reservoirs. Previous studies performed neglected VPL due to suction pressure showed that for initial NaCl mass fractions above threshold values, {open_quotes}sealing{close_quotes} of the block occurs and large amounts of liquid fluid may not be recovered. On the other hand, below the threshold value the matrix block dries out due to fluid production. The inclusion of VPL due to suction pressure does not allow complete vaporization of the liquid phase. As a result, the threshold NaCl concentration above which sealing of the matrix block occurs is increased. Above the {open_quotes}critical{close_quotes} NaCl concentration, block depletion behaviour with and without the VPL due to suction pressure is almost identical, as liquid phase saturation remains high even after long production times. As the VPL due to suction pressure depends mainly on capillary pressure, the shape of capillary pressure functions used in numerical simulations is important in determining VPL effects on block depletion.

  19. 77 FR 7025 - Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI

    Science.gov (United States)

    2012-02-10

    ...-AA00 Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... the America's Cup World Series sailing vessel racing event. This safety zone is intended to safeguard...'s Cup-class races on the waters of the East Passage, Narragansett Bay, Rhode Island. Vessels will be...

  20. Effects of wet-cupping on blood pressure in hypertensive patients: a randomized controlled trial.

    Science.gov (United States)

    Aleyeidi, Nouran A; Aseri, Khaled S; Matbouli, Shadia M; Sulaiamani, Albaraa A; Kobeisy, Sumayyah A

    2015-11-01

    Although cupping remains a popular treatment modality worldwide, its efficacy for most diseases, including hypertension, has not been scientifically evaluated. We aimed to determine the efficacy of wet-cupping for high blood pressure, and the incidence of the procedure's side effects in the intervention group. This is a randomized controlled trial conducted in the General Practice Department at King Abdulaziz University Hospital, Jeddah, Saudi Arabia, between May 2013 and February 2014. There were two groups (40 participants each): intervention group undergoing wet-cupping (hijama) in addition to conventional hypertension treatment, and a control group undergoing only conventional hypertension treatment. Three wet-cupping sessions were performed every other day. The mean systolic and diastolic blood pressures were measured using a validated automatic sphygmomanometer. The follow-up period was 8 weeks. Wet-cupping provided an immediate reduction of systolic blood pressure. After 4 weeks of follow-up, the mean systolic blood pressure in the intervention group was 8.4 mmHg less than in the control group (P=0.046). After 8 weeks, there were no significant differences in blood pressures between the intervention and control groups. In this study, wet-cupping did not result in any serious side effects. Wet-cupping therapy is effective for reducing systolic blood pressure in hypertensive patients for up to 4 weeks, without serious side effects. Wet-cupping should be considered as a complementary hypertension treatment, and further studies are needed. ClinicalTrials.gov Identifier NCT01987583.

  1. Dynamic stiffness of suction caissons - torsion, sliding and rocking

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the skirt length and the Poisson's ratio of the subsoil. Finally, the high-frequency impedance has been determined for future use in lumped-parameter models of wind turbine foundations in aero-elastic codes. (au)

  2. Cupping therapy: A prudent remedy for a plethora of medical ailments

    Directory of Open Access Journals (Sweden)

    Piyush Mehta

    2015-07-01

    Full Text Available Since ancient times, complementary and alternative medicine (CAM; 補充與替代醫學 bǔ chōng yǔ tì dài yī xué have played an important role in human health and welfare. Many therapeutic approaches in healthcare outside the realm of conventional medicine persist in various parts of the world. There is considerable scientific and commercial potential in CAM, which needs to be explored precisely. Cupping therapy (拔罐療法 bá guàn liáo fǎ, one of the CAM, is practiced across the world. This therapy is believed to act by correcting imbalances in the internal bio field, such as by restoring the flow of “Qi (氣qì”. Cupping involves applying a heated cup to generate a partial vacuum that mobilizes the blood flow and promotes effective healing. This review outlines various tools and techniques of cupping therapy.

  3. Timer switch to convert suction apparatus for negative pressure wound therapy application

    Directory of Open Access Journals (Sweden)

    Surath Amarnath

    2014-01-01

    Full Text Available Background: Negative pressure wound therapy (NPWT is an established modality in the treatment of chronic wounds, open fractures, and post-operative wound problems. This method has not been widely used due to the high cost of equipment and consumables. This study demonstrates an indigenously developed apparatus which gives comparable results at a fraction of the cost. Readily available materials are used for the air-tight dressing. Materials and Methods: Equipment consists of suction apparatus with adjustable pressure valve set to a pressure 125-150 mmHg. An electronic timer switch with a sequential working time of 5 min and a standby time of 3 min provides the required intermittent negative pressure. Readily available materials such as polyvinyl alcohol sponge, suction drains and steridrapes were used to provide an air tight wound cover. Results: A total of 90 cases underwent 262 NPWT applications from 2009 to 2014. This series, comprised of 30 open fractures, 21 post-operative and 39 chronic wounds. The wound healing rate in our study was comparable to other published studies using NPWT. Conclusion: The addition of electronic timer switch will convert a suction apparatus into NPWT machine, and the results are equally effective compared to more expensive counter parts. The use of indigenous dressing materials reduces the cost significantly.

  4. Development of a New Delivery and Attachment System for Tagging Large Cetaceans

    National Research Council Canada - National Science Library

    Harvey, James

    1997-01-01

    .... We developed a new method of delivering tags for placement on large whales. Sea lions were trained to carry a harness and attached camera system along with carrying a suction-cup tag in a mouth piece...

  5. Dtags beluga whale data collected from Bristol Bay by Alaska Fisheries Scientific Center, National Marine Mammal Laboratory from 2011-05-01 to 2014-08-31 (NCEI Accession 0142174)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Suction cup attached multi-sensor tags were placed on beluga whales in Bristol Bay, Alaska, to collect depth, 3D acceleration and sound. Data were coupled with...

  6. [YANG's pricking-cupping therapy for knee osteoarthritis: a multi-center randomized controlled trial].

    Science.gov (United States)

    Wang, Bo; Liu, Xiru; Hu, Zhihai; Sun, Aijun; Ma, Yanwen; Chen Yingying; Zhang, Xuzhi; Liu, Meiling; Wang, Yi; Wang, Shuoshuo; Zhang, Yunjia; Li, Yijing; Shen, Weidong

    2016-02-01

    To evaluate the clinical efficacy of YANG's pricking-cupping therapy for knee osteoar thritis (KOA). Methods This was a multi-center randomized parallel controlled trial. One hundred and seventy one patients with KOA were randomly allocated to a pricking-cupping group (89 cases) and a conventional acu puncture group (82 cases). Neixiyan (EX-LE 4), Dubi (ST 35) and ashi points were selected in the two groups. Patients in the pricking-cupping group were treated with YANG's pricking-cupping therapy; the seven-star needles were used to perform pricking at acupoints, then cupping was used until slight bleeding was observed. Patients in the conventional acupuncture group were treated with semi-standardized filiform needle therapy. The treatment was given for 4 weeks (from a minimum of 5 times to a maximum of 10 times). The follow-up visit was 4 weeks. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the visual analogue scale (VAS) were adopted for the efficacy assessments. The pain score, stiffness score, physical function score and total score of WOMAC were all reduced after 4-week treatment and during follow-up visit in the two groups (all P0. 05), each score and total score of WOMAC in the pricking-cupping group were lower than those in the conventional acupuncture group after 4-week treatment and during follow-up visit (Pcupping group were lower than those in the conventional acupuncture group after 4-week treatment and during follow-up visit (P cupping and conventional acupuncture therapy can both significantly improve knee joint pain and function in patients with KOA, which are relatively safe. The pricking cupping therapy is superior to conventional acupuncture with the identical selection of acupoints.

  7. Diagnose of large area electron beam with faraday cup

    International Nuclear Information System (INIS)

    Tang Ying; Qian Hang; Yi Aiping; Huang Xin; Yu Li; Liu Jingru; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2008-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. This paper introduces Faraday cup is used in the diagnose experiment on the uniformity of large area e-beam generated by SPG-200 pulsed power generator. Construction of Faraday cup and the results of calibration are presented in detail. The uniformity of velvet emission is given, and the results of experiment are analyzed. (authors)

  8. A novel cupping-assisted plasma treatment for skin disinfection

    Science.gov (United States)

    Xiong, Zilan; Graves, David B.

    2017-02-01

    A novel plasma treatment method/plasma source called cupping-assisted plasma treatment/source for skin disinfection is introduced. The idea combines ancient Chinese ‘cupping’ technology with plasma sources to generate active plasma inside an isolated, pressure-controlled chamber attached to the skin. Advantages of lower pressure include reducing the threshold voltage for plasma ignition and improving the spatial uniformity of the plasma treatment. In addition, with reduced pressure inside the cup, skin pore permeability might be increased and it improves attachment of the plasma device to the skin. Moreover, at a given pressure, plasma-generated active species are restricted inside the cup, raising local reactive species concentration and enhancing the measured surface disinfection rate. A surface micro-discharge (SMD) device is used as an example of a working plasma source. We report discharge characteristics and disinfection efficiency as a function of pressure and applied voltage.

  9. A Comparison of delO18 Composition of Water Extracted from Suction Lysimeters, Centrifugation, and Azeotropic Distillation

    Science.gov (United States)

    Figueroa, A.; Tindall, J. A.; Friedel, M. J.

    2005-12-01

    Concentration of delO18 in water samples extracted by suction lysimeters is compared to samples obtained by methods of centrifugation and azeotropic distillation. Intact soil cores (30 cm diameter by 40 cm height) were extracted from two different sites. Site 1 was rapid infiltration basin number 50, near Altamonte Springs in Seminole County, Florida on properties belonging to the Walt Disney World Resort Complex. Site 2 was the Missouri Management System Evaluation Area (MSEA) near Centralia in Boone County, Missouri. The delO18 water was analyzed on a mass spectrophotometer. Potassium Bromide (KBr) was also used as a tracer and analyzed by ion chromatography. A portion of the data obtained was modeled using CXTFIT. Water collected by centrifugation and azeotropic distillation data were about 2-5% more negative than that collected by suction lysimeter values from the Florida (sandy) soil and about 5-7 % more negative from the Missouri (well structured clay) soil. Results indicate that the majority of soil water in well structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. Also, it is plausible that evaporation caused some delO18 enrichment in the suction lysimeters. Suction lysimeters preferentially sampled water held at lower matric potentials, which may not represent total soil water. In cases where a sufficient volume of water has passed through the soil profile and displaced all previous pore water, suction lysimeters will however collect a representative sample of all the water at that depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeters be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The CXTFIT program worked well for Florida soils (a more homogeneous sand), but gave poor performance for Missouri soils (well structured clays) except for deeper depths where clay structure was less

  10. Evaluation of a menstrual cup to collect shed endometrium for in vitro studies.

    Science.gov (United States)

    Koks, C A; Dunselman, G A; de Goeij, A F; Arends, J W; Evers, J L

    1997-09-01

    To evaluate whether a menstrual cup is a suitable instrument to collect antegradely shed endometrium for in vitro studies. A prospective, descriptive, cell biological and immunohistochemical study. Tertiary care university medical center. Nine female volunteers with regular cycles. Menstrual effluent was collected with a menstrual cup. Experience with the menstrual cup was described. Cytospin specimens, frozen sections, and cultures were prepared from the obtained menstrual tissue. The acceptability of the menstrual cup. The presence and viability of endometrial tissue was evaluated using immunohistochemical staining and culture outcome. All women except one described the menstrual cup as acceptable. Menstrual effluent contained single cells, clumps of cells, and glandlike structures. After 5 days of culture, the endometrial tissue appeared to be viable. Immunohistochemistry showed positive staining for vimentin in most cytospin specimens, in all cryostat specimens, and in 10 of 17 cultures. Cytokeratin 18 stained most cytospin specimens, all cryostat specimens, and 10 of 17 cultures. Positive staining for BW495/36 was observed in most cytospin specimens, all cryostat specimens, and 11 of 17 cultures. A menstrual cup in an acceptable instrument to collect antegradely shed menstrual tissue. Menstruum contains viable endometrial tissue that can be used for in vitro studies of endometrium and endometriosis.

  11. dlx and sp6-9 Control optic cup regeneration in a prototypic eye.

    Directory of Open Access Journals (Sweden)

    Sylvain W Lapan

    2011-08-01

    Full Text Available Optic cups are a structural feature of diverse eyes, from simple pit eyes to camera eyes of vertebrates and cephalopods. We used the planarian prototypic eye as a model to study the genetic control of optic cup formation and regeneration. We identified two genes encoding transcription factors, sp6-9 and dlx, that were expressed in the eye specifically in the optic cup and not the photoreceptor neurons. RNAi of these genes prevented formation of visible optic cups during regeneration. Planarian regeneration requires an adult proliferative cell population with stem cell-like properties called the neoblasts. We found that optic cup formation occurred only after migration of progressively differentiating progenitor cells from the neoblast population. The eye regeneration defect caused by dlx and sp6-9 RNAi can be explained by a failure to generate these early optic cup progenitors. Dlx and Sp6-9 genes function as a module during the development of diverse animal appendages, including vertebrate and insect limbs. Our work reveals a novel function for this gene pair in the development of a fundamental eye component, and it utilizes these genes to demonstrate a mechanism for total organ regeneration in which extensive cell movement separates new cell specification from organ morphogenesis.

  12. Enhancement of optic cup detection through an improved vessel kink detection framework

    Science.gov (United States)

    Wong, Damon W. K.; Liu, Jiang; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Wong, Tien Yin

    2010-03-01

    Glaucoma is a leading cause of blindness. The presence and extent of progression of glaucoma can be determined if the optic cup can be accurately segmented from retinal images. In this paper, we present a framework which improves the detection of the optic cup. First, a region of interest is obtained from the retinal fundus image, and a pallor-based preliminary cup contour estimate is determined. Patches are then extracted from the ROI along this contour. To improve the usability of the patches, adaptive methods are introduced to ensure the patches are within the optic disc and to minimize redundant information. The patches are then analyzed for vessels by an edge transform which generates pixel segments of likely vessel candidates. Wavelet, color and gradient information are used as input features for a SVM model to classify the candidates as vessel or non-vessel. Subsequently, a rigourous non-parametric method is adopted in which a bi-stage multi-resolution approach is used to probe and localize the location of kinks along the vessels. Finally, contenxtual information is used to fuse pallor and kink information to obtain an enhanced optic cup segmentation. Using a batch of 21 images obtained from the Singapore Eye Research Institute, the new method results in a 12.64% reduction in the average overlap error against a pallor only cup, indicating viable improvements in the segmentation and supporting the use of kinks for optic cup detection.

  13. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation.

    Science.gov (United States)

    Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien

    2014-09-01

    Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Thopaz Portable Suction Systems in Thoracic Surgery: An end user assessment and feedback in a tertiary unit

    Directory of Open Access Journals (Sweden)

    Cantlin Teresa

    2011-04-01

    Full Text Available Abstract Background Thoracic surgical patients have chest drains inserted to enable re-expansion of lungs, to clear contents from the pleural cavity which sometimes require negative suction. Suction impedes mobility, may have variable suction delivery and increases risk of infection. Assessment of air-leak in conventional drains is not scientific and is subjective. Thopaz chest drain system is a portable suction unit which allows mobilization of the patient, with scientific digital flow recordings and an in built alarm system. Methods We evaluated the utility, staff and patient feedback of this device in a pilot evaluation in a regional thoracic unit in a structured format over a period of two months. Staff responses were graded on a scale of 1 to 6 [1 Excellent to 6 Poor]. Results 120 patients who underwent elective bullectomy/pleurectomy, VATS lung biopsies, VATS metastectomy and lung resections were evaluated. The staff feedback forms were positive. The staff liked the system as it was more scientific and accurately recordable. It made nursing and physiotherapy easier as they could mobilise patients early. The patients liked the compact design, weightlessness and the silence. It enabled mobilisation of the patients and scientific removal of chest drain. Conclusions Thopaz digital suction units were found to be user friendly and were liked by the staff and patients. The staff feedback stated the devices to be objective and scientific in making decisions about removal and enabled mobilisation.

  15. 77 FR 20846 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items and Packaging Thereof...

    Science.gov (United States)

    2012-04-06

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-835] Certain Food Containers, Cups, Plates... the sale within the United States after importation of certain food containers, cups, plates, cutlery... importation, or the sale within the United States after importation of certain food containers, cups, plates...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... to the journals may be interrupted during this time. We are working to resolve the issue quickly ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ...

  18. Microsatellite marker analysis of peach-potato aphids (Myzus persicae, Homoptera: Aphididae) from Scottish suction traps.

    Science.gov (United States)

    Malloch, G; Highet, F; Kasprowicz, L; Pickup, J; Neilson, R; Fenton, B

    2006-12-01

    The peach-potato aphid Myzus persicae (Sulzer) is an important vector of plant viruses. A network of suction traps collects aerial samples of this aphid in order to monitor and help predict its spatial distribution and likely impact on virus transmission in crops. A suction trap catch is thought to be a good representation of the total aphid pool. Sensitive molecular markers have been developed that determine the genetic composition of the M. persicae population. In Scotland, UK, these were applied to field collections revealing a limited number of clones. Molecular markers are less successful when applied to specimens that have been preserved in an ethanol-based trap fluid designed to preserve morphology. An assessment of different DNA extraction and PCR techniques is presented and the most efficient are used to analyse M. persicae specimens caught in the Dundee suction trap in 2001, a year when exceptionally high numbers were caught. The results reveal that the majority of the M. persicae caught belonged to two highly insecticide resistant clones. In addition, it was possible to compare the relative frequencies of genotypes caught in the trap with those collected at insecticide treated and untreated field sites in the vicinity. These results indicate that, in addition to suction trap data, the ability to sample field sites provides valuable early warning data which have implications for pest control and virus management strategies.

  19. A geometric morphometric assessment of the optic cup in glaucoma.

    Science.gov (United States)

    Sanfilippo, Paul G; Cardini, Andrea; Sigal, Ian A; Ruddle, Jonathan B; Chua, Brian E; Hewitt, Alex W; Mackey, David A

    2010-09-01

    The morphologic appearance of the optic disc is of interest in glaucoma. In contrast to descriptive classification systems that are currently used, a quantitative approach to the analysis of optic disc morphology is required. Our goal was to determine the optimal method for quantifying optic cup shape by comparing traditional (ovality, form-factor and neuroretinal rim (NRR) width ratio) and geometric morphometric approaches. Left optic disc stereophotographs of 160 (80 normal and 80 glaucomatous (stratified by severity)) subjects were examined. The optic cup margins were stereoscopically delineated with a custom tracing system and saved as a series of discrete points. The geometric morphometric methods of elliptic Fourier analysis (EFA) and sliding semi-landmark analysis (SSLA) were used to eliminate variation unrelated to shape (e.g. size) and yield a series of shape variables. Differences in optic cup shape between normal and glaucoma groups were investigated. Discriminant functions were computed and the sensitivity and specificity of each technique determined. Receiver operator characteristic (ROC) curves were calculated for all methods and evaluated in their potential to discriminate between normal and glaucomatous eyes based on the shape variables. All geometric morphometric methods revealed differences between normal and glaucomatous eyes in optic cup shape, in addition to the traditional parameters of ovality, form-factor and NRR width ratio (pgeometric morphometric approach for discriminating between normal and glaucomatous eyes in optic cup shape is superior to that provided by traditional single parameter shape measures. Such analytical techniques could be incorporated into future automated optic disc screening modalities. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  20. ACCUWIND - Classification of five cup anemometers according to IEC 61400-12-1

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels; Dahlberg, J.-Å.; Busche, P.

    2006-01-01

    The characteristics of five cup anemometers were investigated in detail, and data are presented in figures and tables. The characteristics include: normal wind tunnel calibrations; angular response measurements at 5, 8 and 11m/s; torque coefficient curvemeasurements from combined tilt and ramp......-gust tests, torque coefficient curve measurements for non-tilted conditions; rotor inertia measurements and measurements of friction of bearings at temperatures -10°C to 40°C. The characteristics are fitted to twodifferent time domain cup anemometer models, and simulations of the cup anemometers are made...

  1. Management and marketing of sporting events: Nike Premier Cup Project

    OpenAIRE

    Nedbal, Jakub

    2008-01-01

    Title: Management and marketing ofsporting events: Nike Premier Cup project Points of thesis: Publish the Nike Premier Cup promotion campaign project and point out improvement possibilities for upcoming years based on analysis ofpast and present state. Methods: Data will be obtained by interview, observation, description analysis and SWOT analysis Results: Promotion campaign, improvement possibilities, final day schedule Keywords: SWOT analysis, promotion, management, marketing, Nike Premier ...

  2. Temperature measurement in WTE boilers using suction pyrometers.

    Science.gov (United States)

    Rinaldi, Fabio; Najafi, Behzad

    2013-11-15

    The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE) plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR) pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  3. Temperature Measurement in WTE Boilers Using Suction Pyrometers

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2013-11-01

    Full Text Available The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  4. [Effect of cupping on hemodynamic levels in the regional sucked tissues in patients with lumbago].

    Science.gov (United States)

    Tang, Xiao; Xiao, Xue-Hua; Zhang, Guo-Qing

    2012-10-01

    To observe hemodynamic changes in the local sucked tissue of lower back undergoing negative pressure after cupping in patients with lumbago. Twenty-two lumbago outpatients were recruited in the present study and 32 sucked tissues accepted measurements. The cupping was applied to the tenderpoint of the patients' lower back for 10 min by using a glass-mug (5 cm in diameter). Hemodynamic indexes [peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI)] of the sucked skin and subcutaneous tissues at the lower back were detected before and after cupping by using a color Doppler flow imaging. After cupping intervention at the lower back, the PSV [(14.2 +/- 1.8) cm/s] and EDV [(5.5 +/- 0.7) cm/s] levels were increased significantly in comparison with those [(5.9 +/- 0.9) and (1.9 +/- 0.3) cm/s] before cupping (P cupping (0.61 +/- 0.05 vs 0.68 +/- 0.06, P Cupping therapy can increase the peak systolic velocity and end-diastolic velocity and lower vascular resistance of the subcutaneous arterioles in the regional tissue, which may contribute to its effect in relieving lumbago.

  5. Blood loss associated with Ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage.

    Science.gov (United States)

    Wittmann, F W; Ring, P A

    1984-01-01

    In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978

  6. Influence of Surgical Approach on Pelvic Lift in Hip Arthroplasty During Cup Insertion.

    Science.gov (United States)

    Brodt, Steffen; Windisch, Christoph; Krakow, Linda; Nowack, Dimitri; Matziolis, Georg

    2017-07-01

    The position of the acetabular cup is a major factor in the long-term outcome of total hip arthroplasty (THA). Malpositioning of the acetabular cup frequently has been reported with the use of a minimally invasive implantation technique. It remains unclear whether the limited visibility or the increased retractor traction and thus tilting of the pelvis during cup implantation is the cause. This study investigated the influence of iatrogenically related pelvic lift using an anterolateral minimally invasive THA technique. In a group of 30 consecutive patients who underwent THA via a minimally invasive anterolateral approach, iatrogenic lifting of the pelvis was measured with a smartphone using a 3-axis accelerometer and compared with patients in a historical age- and sex-matched control group who underwent THA using a transgluteal approach. Postoperatively, the inclination and anteversion of the cup was determined on pelvic radiographs. In the anterolateral group, the pelvis was lifted by a maximum of 6.3° and by an average of 3.9° when the acetabular cup was impacted; no difference was noted compared with the transgluteal group. In contrast, the cups in the anterolateral group showed significantly increased inclination and reduced anteversion. In both techniques, the iatrogenic tilting of the pelvis at the time of cup implantation occurred to a comparable extent. Therefore, the significant differences in postoperative radiographs cannot be attributed to increased retractor traction on exposure of the acetabulum, which means that the limited visibility must be responsible. [Orthopedics. 2017; 40(4):e589-e593.]. Copyright 2017, SLACK Incorporated.

  7. A Kirschner wire as a transverse-axis guide to improve acetabular cup positioning.

    Science.gov (United States)

    Ishidou, Y; Hirotsu, M; Setoguchi, T; Nagano, S; Kakoi, H; Yokouchi, M; Yamamoto, T; Komiya, S

    2016-04-01

    To compare cup-positioning accuracy in total hip arthroplasty (THA) with or without use of a Kirschner wire as a transverse-axis guide for pelvic alignment. Records of 18 men and 73 women (mean age, 60 years) who underwent primary THA with (n=49) or without (n=42) use of a Kirschner wire as a transverse-axis guide for pelvic alignment were reviewed. A 2.4-mm Kirschner wire as a transversea-xis guide was inserted to the anterior superior iliac spine and was parallel to a line linking the left and right anterior superior iliac spine. The safe zone for cup positioning was defined as 30º to 50° abduction and 10º to 30º anteversion. Of the 5 operative surgeons, 2 were classified as experienced (total surgical volume >300) and 3 as inexperienced (total surgical volume of cup in the safe zone was compared in patients with or without use of the transverse-axis guide and in experienced and inexperienced surgeons. For inexperienced surgeons, the use of the transverse-axis guide significantly improved the proportion of patients with the cup in the safe zone from 90% to 100% for abduction, from 50% to 82.4% for anteversion, and from 40% to 82.4% for both. Patients with the cup inside or outside the safe zone were comparable in terms of body height, weight, BMI, subcutaneous fat thickness, incision length, and acetabular cup size. The use of the transverse-axis guide improved the accuracy of cup positioning by inexperienced surgeons.

  8. Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral approach?

    Science.gov (United States)

    Song, Xinggui; Ni, Ming; Li, Heng; Li, Xin; Li, Xiang; Fu, Jun; Chen, Jiying

    2018-05-23

    The impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (THA) is not well studied. The aim of our study is to investigate the difference of cup orientation in bilateral THA performed by right-handed surgeons using posterolateral approach and which cup could be fitter to Lewinneck's safe zone. The study consisted of 498 patients that underwent bilateral THA by three right-handed surgeons in our hospital. Postoperative acetabular cup anteversion and abduction on an anteroposterior pelvic radiograph were measured by Orthoview software (Orthoview LLC, Jacksonville, Florida). Furthermore, the percentage of cup placement within the safe zone was compared. The mean anteversion was 25.28 (25.28° ± 7.16°) in left THA and 22.01 (22.01° ± 6.35°) in right THA (p cup was positioned in Lewinnek's safe zone in 52% for anteversion, 87% for abduction, and 46% for both anteversion and abduction. But the cup placement within Lewinnek's safe zone was 71, 88, and 62% in the right side, respectively. There were significant differences in the percentage of acetabular cup placement within the safe zone for anteversion (p cup inclination and anteversion in bilateral THA and that the placement of cup performed by dominant hands of surgeons is more accurate than that performed by non-dominant sides.

  9. The age grading and the Chen-Ruan cup product

    DEFF Research Database (Denmark)

    A. Hepworth, Richard

    2010-01-01

    We prove that the obstruction bundle used to define the cup-product in Chen-Ruan cohomology is determined by the so-called `age grading' or `degree-shifting numbers'. Indeed, the obstruction bundle can be directly computed using the age grading. We obtain a Kunneth Theorem for Chen-Ruan cohomology...... as a direct consequence of an elementary property of the age grading, and explain how several other results - including associativity of the cup-product - can be proved in a similar way....

  10. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver Cup...

  11. Validation of 3D sonic-anemometer against cup anemometer response

    DEFF Research Database (Denmark)

    Hansen, Kurt Schaldemose; Larsen, Gunner Chr.; Courtney, Michael

    2004-01-01

    Determination and validation of wind turbine power curves traditionally rely on single point wind speed measurements recorded with a calibrated cup-anemometer. The power curve verification process, which is typically performed in different terrain types, does not always result in satisfactory...... agreement between measures- and predicted power curves. The observed disagreement is premarily believed to relate to the cup-anemometers being sensitive to tilted flow i.e. that the measurement of the horizontal flow component is sensible to flow in a plane perpendicular to the horizontal plane. Furthermore......, the limited cup-anemometer response due to high turbulence can explain some of the diviations. The present paper investigates this problem, by analysing full-scale time series data extracted from "Database on Wind Characteristics" (http://www.winddata.com/), which represents a wide range of sites. Basically...

  12. Hydrogenation study of suction-cast Ti{sub 40}Zr{sub 40}Ni{sub 20} quasicrystal

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huogen; Li, Rong; Yin, Chen; Zheng, Shaotao; Zhang, Pengcheng [National Key Laboratory for Surface Physics and Chemistry, P.O. Box 718-35, Mian Yang 621907, Sichuan (China)

    2008-09-15

    Suction casting was predicted to be an usable method for improving the hydriding kinetics of Ti/Zr-based icosahedral quasicrystals (IQCs) in our previous work. To further determine it, a suction-cast Ti{sub 40}Zr{sub 40}Ni{sub 20} IQC alloy was used for hydrogenation studies by Pressure Composition Isotherm (PCI) and Temperature Programmed Desorption (TPD) techniques. The results showed that, this alloy absorbed hydrogen rapidly with obvious hydrogen pressure plateau and some reversibility, however, displayed very limited hydrogen capacity (about 0.7 wt.%) and low equilibrium pressure. After several hydrogenation/dehydrogenation cycles, the IQC structure transformed into two hydride phases, ZrH{sub 2-x} and one unknown, both of which decomposed at above 600 C, suggesting high thermo-stability for them. On the whole, indeed the suction-casting method can increase the hydrogen absorption rate of Ti/Zr-based IQCs, however, the hydrogenation properties of the Ti{sub 40}Zr{sub 40}Ni{sub 20} IQC alloy still need a mighty advancement. (author)

  13. Effect of palady and cup feeding on premature neonates' weight gain and reaching full oral feeding time interval.

    Science.gov (United States)

    Marofi, Maryam; Abedini, Fatemeh; Mohammadizadeh, Majid; Talakoub, Sedigheh

    2016-01-01

    Premature neonates' feeding is of great importance due to its effective role in their growth. These neonates should reach an independent oral nutrition stage before being discharged from the Neonatal Intensive care Unit. Therefore, the researcher decided to conduct a study on the effect of palady and cup feeding on premature neonates' weight gain and their reaching full oral feeding time interval. This is a clinical trial with a quantitative design conducted on 69 premature infants (gestational age between 29 and 32 weeks) who were assigned to cup (n = 34) and palady (n = 35) feeding groups through random allocation. The first feeding was administrated either by cup or palady method in each shift within seven sequential days (total of 21 cup and palady feedings). Then, the rest of feeding was administrated by gavage. Mean hospitalization time (cup = 39.01 and palady = 30.4; P cup = 33.7 and palady = 24.1; P cup group. Mean weight changes of neonates 7 weeks after the intervention compared to those in the beginning of the intervention were significantly more in palady group compared to the cup group (cup = 146.7 and palady = 198.8; P cup group. Subjects' weight gain was also higher in palady group compared to the cup group. Premature neonates with over 30 weeks of gestational age and physiological stability can be fed by palady.

  14. Open cup nests evolved from roofed nests in the early passerines.

    Science.gov (United States)

    Price, J Jordan; Griffith, Simon C

    2017-02-08

    The architectural diversity of nests in the passerine birds (order Passeriformes) is thought to have played an important role in the adaptive radiation of this group, which now comprises more than half of avian species and occupies nearly all terrestrial ecosystems. Here, we present an extensive survey and ancestral state reconstruction of nest design across the passerines, focusing on early Australian lineages and including members of nearly all passerine families worldwide. Most passerines build open cup-shaped nests, whereas a minority build more elaborate domed structures with roofs. We provide strong evidence that, despite their relative rarity today, domed nests were constructed by the common ancestor of all modern passerines. Open cup nests evolved from enclosed domes at least four times independently during early passerine evolution, at least three of which occurred on the Australian continent, yielding several primarily cup-nesting clades that are now widespread and numerically dominant among passerines. Our results show that the ubiquitous and relatively simple cup-shaped nests of many birds today evolved multiple times convergently, suggesting adaptive benefits over earlier roofed designs. © 2017 The Author(s).

  15. Pulsatile dry cupping in chronic low back pain - a randomized three-armed controlled clinical trial.

    Science.gov (United States)

    Teut, M; Ullmann, A; Ortiz, M; Rotter, G; Binting, S; Cree, M; Lotz, F; Roll, S; Brinkhaus, B

    2018-04-02

    We aimed to investigate the effectiveness of two different forms of dry pulsatile cupping in patients with chronic low back pain (cLBP) compared to medication on demand only in a three-armed randomized trial. 110 cLBP patients were randomized to regular pulsatile cupping with 8 treatments plus paracetamol on demand (n = 37), minimal cupping with 8 treatments plus paracetamol on demand (n = 36) or the control group with paracetamol on demand only (n = 37). Primary outcome was the pain intensity on a visual analogue scale (VAS, 0-100 mm) after 4 weeks, secondary outcome parameter included VAS pain intensity after 12 weeks, back function as measured with the 'Funktionsfragebogen Hannover Rücken' (FFbH-R) and health related quality of life questionnaire Short form 36 (SF-36) after 4 and 12 weeks. The mean baseline-adjusted VAS after 4 weeks was 34.9 mm (95% CI: 28.7; 41.2) for pulsatile cupping, 40.4 (34.2; 46.7) for minimal cupping and 56.1 (49.8; 62.4) for control group, resulting in statistically significant differences between pulsatile cupping vs. control (21.2 (12.2; 30.1); p back function after 4 weeks, but not after 12 weeks (- 5.4 (- 11.7;0.8); p = 0.088), pulsatile cupping also showed better improvements on SF-36 physical component scale compared to control at 4 and 12 weeks (- 5.6 (- 9.3;-2.0); p = 0.003; - 6.1 (- 9.9;-2.4); p = 0.002). For back function and quality of life minimal cupping group was not statistically different to control after 4 and 12 weeks. Paracetamol intake did not differ between the groups (cupping vs. control (7.3 (- 0.4;15.0); p = 0.063); minimal cupping vs. control (6.3 (- 2.0;14.5); p = 0.133). Both forms of cupping were effective in cLBP without showing significant differences in direct comparison after four weeks, only pulsatile cupping showed effects compared to control after 12 weeks. The study was registered at ClinicalTrials.gov (identifier: NCT02090686 ).

  16. Evaluating lysimeter drainage against soil deep percolation modeled with profile soil moisture, field tracer propagation, and lab measured soil hydraulic properties

    DEFF Research Database (Denmark)

    Vasquez, Vicente; Thomsen, Anton Gårde; Iversen, Bo Vangsø

    them have been reported. To compare among methods, one year of four large-scale lysimeters drainage (D) was evaluated against modeled soil deep percolation using either profile soil moisture, bromide breakthrough curves from suction cups, or measured soil hydraulic properties in the laboratory....... Measured volumetric soil water content (q) was 3-4% higher inside lysimeters than in the field probably due to a zero tension lower boundary condition inside lysimeters. D from soil hydraulic properties measured in the laboratory resulted in a 15% higher evapotranspiration and 12% lower drainage...... predictions than the model calibrated with field measured q. Bromide (Br) breakthrough curves indicated high variability between lysimeters and field suction cups with mean Br velocities at first arrival time of 110 and 33 mm/d, respectively. D was 520 mm/yr with lysimeters, 613 mm/yr with the calibrated...

  17. Silent cooling system with a double suction type centrifugal fan with backward blades; Ryosuikomi turbo fan wo mochiita teisoon engine reikyaku system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Funabashi, S. [Hitachi, Ltd., Tokyo (Japan); Nakamura, K. [Hitachi Construction Machinery Co. Ltd., Tokyo (Japan)

    2000-04-25

    We have developed a new cooling system for the engine of construction machinery. This system produces two different air flow routes by a double suction type centrifugal fan with backward blades. We first measured aerodynamic performance and sound level of the double suction type fan, which consists of two single suction type fans of different design, and compared these measurements to those of single suction type fans. Next, we installed the fan in a scale model of the new cooling system. The performance of this double suction type fan was different to that of a single suction type. It is considered that the effect of interaction of the exit flows from the two different fans caused this performance change. The test model installed in an engine compartment showed that this cooling system reduced the area of air inlets and outlets around the engine and did not cause re-circulation of cooling air. (author)

  18. 78 FR 57482 - Safety Zone; America's Cup Aerobatic Box, San Francisco Bay, San Francisco, CA

    Science.gov (United States)

    2013-09-19

    ...-AA00 Safety Zone; America's Cup Aerobatic Box, San Francisco Bay, San Francisco, CA AGENCY: Coast Guard... America's Cup air shows. These safety zones are established to provide a clear area on the water for... announced by America's Cup Race Management. ADDRESSES: Documents mentioned in this preamble are part of...

  19. Heat-transfer and pressure distributions for laminar separated flows downstream of rearward-facing steps with and without mass suction

    Science.gov (United States)

    Brown, R. D.; Jakubowski, A. K.

    1974-01-01

    Heat-transfer and pressure distributions were measured for laminar separated flows downstream of rearward-facing steps with and without mass suction. The flow conditions were such that the boundary-layer thickness was comparable to or larger than the step height. For both suction and no-suction cases, an increase in the step height resulted in a sharp decrease in the initial heat-transfer rates behind the step. Downstream, however, the heat transfer gradually recovered back to less than or near attached-flow values. Mass suction from the step base area increased the local heat-transfer rates; however, this effect was relatively weak for the laminar flows considered. Even removal of the entire approaching boundary layer raised the post-step heat-transfer rates only about 10 percent above the flatplate values. Post-step pressure distributions were found to depend on the entrainment conditions at separation. In the case of the solid-faced step, a sharp pressure drop behind the step was followed by a very short plateau and relatively fast recompression. For the slotted-step connected to a large plenum but without suction, the pressure drop at the base was much smaller and the downstream recompression more gradual than that for solid-faced step.

  20. Coffee Cup Atomic Force Microscopy

    Science.gov (United States)

    Ashkenaz, David E.; Hall, W. Paige; Haynes, Christy L.; Hicks, Erin M.; McFarland, Adam D.; Sherry, Leif J.; Stuart, Douglas A.; Wheeler, Korin E.; Yonzon, Chanda R.; Zhao, Jing; Godwin, Hilary A.; Van Duyne, Richard P.

    2010-01-01

    In this activity, students use a model created from a coffee cup or cardstock cutout to explore the working principle of an atomic force microscope (AFM). Students manipulate a model of an AFM, using it to examine various objects to retrieve topographic data and then graph and interpret results. The students observe that movement of the AFM…

  1. Effects of traditional cupping therapy in patients with carpal tunnel syndrome: a randomized controlled trial.

    Science.gov (United States)

    Michalsen, Andreas; Bock, Silke; Lüdtke, Rainer; Rampp, Thomas; Baecker, Marcus; Bachmann, Jürgen; Langhorst, Jost; Musial, Frauke; Dobos, Gustav J

    2009-06-01

    We investigated the effectiveness of cupping, a traditional method of treating musculoskeletal pain, in patients with carpal tunnel syndrome (CTS) in an open randomized trial. n = 52 outpatients (58.5 +/- 8.0 years) with neurologically confirmed CTS were randomly assigned to either a verum (n = 26) or a control group (n = 26). Verum patients were treated with a single application of wet cupping, and control patients with a single local application of heat within the region overlying the trapezius muscle. Patients were followed up on day 7 after treatment. The primary outcome, severity of CTS symptoms (VAS), was reduced from 61.5 +/- 20.5 to 24.6 +/- 22.7 mm at day 7 in the cupping group and from 67.1 +/- 20.2 to 51.7 +/- 23.9 mm in the control group [group difference -24.5mm (95%CI -36.1; -2.9, P cupping therapy may be effective in relieving the pain and other symptoms related to CTS. The efficacy of cupping in the long-term management of CTS and related mechanisms remains to be clarified. The results of a randomized trial on the clinical effects of traditional cupping therapy in patients with carpal tunnel syndrome are presented. Cupping of segmentally related shoulder zones appears to alleviate the symptoms of carpal tunnel syndrome.

  2. Modeling of Flexible Polyurethane Foam Shrinkage for Bra Cup Moulding Process Control

    Directory of Open Access Journals (Sweden)

    Long Wu

    2018-04-01

    Full Text Available Nowadays, moulding technology has become a remarkable manufacturing process in the intimate apparel industry. Polyurethane (PU foam sheets are used to mould three-dimensional (3D seamless bra cups of various softness and shapes, which eliminate bulky seams and reduce production costs. However, it has been challenging to accurately and effectively control the moulding process and bra cup thickness. In this study, the theoretical mechanism of heat transfer and the thermal conductivity of PU foams are first examined. Experimental studies are carried out to investigate the changes in foam materials at various moulding conditions (viz., temperatures, and lengths of dwell time in terms of surface morphology and thickness by using electron and optical microscopy. Based on the theoretical and experimental investigations of the thermal conductivity of the foam materials, empirical equations of shrinkage ratio and thermal conduction of foam materials were established. A regression model to predict flexible PU foam shrinkage during the bra cup moulding process was formulated by using the Levenberg-Marquardt method of nonlinear least squares algorithm and verified for accuracy. This study therefore provides an effective approach that optimizes control of the bra cup moulding process and assures the ultimate quality and thickness of moulded foam cups.

  3. Active technique by suction to control the flow structure over a van model

    Science.gov (United States)

    Harinaldi, Budiarso, Warjito, Kosasih, Engkos A.; Tarakka, Rustan; Simanungkalit, Sabar P.

    2012-06-01

    Today research trend in car aerodynamics are carried out from the point of view of the durable development. Some car companies have the objective to develop control solution that enable to reduce the aerodynamic drag of vehicle. It provides the possibility to modify the flow separation to reduce the development of the swirling structures around the vehicle. In this study, a family van is modeled with a modified form of Ahmed's body by changing the orientation of the flow from its original form (modified/reversed Ahmed Body). This model is equipped with a suction on the rear side to comprehensively examine the pressure field modifications that occur. The investigation combines computational and experimental work. The computational simulation used is k-epsilon flow turbulence model. The reversed Ahmed body used in the investigation has slant angle (φ) 35° at the front part. In the computational work, meshing type is tetra/hybrid element with hex core type and the grid number is more than 1.7 million in order to ensure detail discretization and more accurate calculation results. The boundary condition is upstream velocity of 11.1 m/s. Mean free stream at far upstream region is assumed in a steady state condition and uniform. The suction velocity is set at 1 m/s. Meanwhile in the experimental work a reversed Ahmed model is tested in a controlled wind tunnel experiments. The main measurement is the drag aerodynamic measurement at rear of the body of the model using strain gage. The results show that the application of a suction in the rear part of the van model give the effect of reducing the wake and the vortex is formed. Aerodynamic drag reduction close to 24% for the computational approach and 14.8% for the experimental approach by introducing a suction have been obtained.

  4. The Effects of Cupping on Hamstring Flexibility in Collegiate Soccer Players.

    Science.gov (United States)

    Williams, Jeffrey G; Gard, Hannah I; Gregory, Jeana M; Gibson, Amy; Austin, Jennifer

    2018-01-24

    Collegiate soccer players suffer hamstring injuries due to inflexibility and repetitive motions involving intense hamstring lengthening and contraction during sport. Although a popular intervention for muscular injury, there exists limited evidence of the effects of therapeutic cupping on hamstring flexibility. To determine the effect of cupping therapy on hamstring flexibility in collegiate soccer players. Cohort design. Athletic training clinic. Twenty-five, asymptomatic, NCAA Division III soccer players (10 males, 15 females) (age = 19.4 ± 1.30 years, height = 175.1 ± 8.2 cm, mass = 69.5 ± 6.6 kg). A 7-minute therapeutic cupping treatment was delivered to the treatment group. Four 2-inch cups were fixed atop trigger point locations within the hamstring muscle bellies of participants' dominant legs. Control group participants received no intervention between pre- and post-test measurements. Pretest and posttest measurements of hamstring flexibility, using a Passive Straight Leg Raise (PSLR), were performed on both groups. PSLR measurements were conducted by blinded examiners using a digital inclinometer. An independent samples t-test was used to analyze changes in hamstring flexibility from pre- to post-treatment with p-values set a priori at 0.05. An independent samples t-test demonstrated no significant difference in change in hamstring flexibility between participants in the treatment group and those in the control group (t 23 = -.961, p = .35). The findings of this study demonstrated no statistically significant changes in hamstring flexibility following a cupping treatment.

  5. Suction blister lesions and epithelialization monitored by optical coherence tomography

    DEFF Research Database (Denmark)

    Ahlström, M G; Gjerdrum, L M R; Larsen, H F

    2018-01-01

    suction blister was raised on each buttock, and the blister roof was excised. Lesions were covered with moisture-retaining dressing. In Study 1, the lesions were OCT-scanned on day 0 (D0), D2 and D4 and excised for histological examination. In Study 2, the progress of epithelialization and skin barrier...

  6. FLOW (finding lasting options for women): multicentre randomized controlled trial comparing tampons with menstrual cups.

    Science.gov (United States)

    Howard, Courtney; Rose, Caren Lee; Trouton, Konia; Stamm, Holly; Marentette, Danielle; Kirkpatrick, Nicole; Karalic, Sanja; Fernandez, Renee; Paget, Julie

    2011-06-01

    To determine whether menstrual cups are a viable alternative to tampons. Randomized controlled trial. Prince George, Victoria, and Vancouver, BC. A total of 110 women aged 19 to 40 years who had previously used tampons as their main method of menstrual management. Participants were randomized into 2 groups, a tampon group and a menstrual cup group. Using online diaries, participants tracked 1 menstrual cycle using their regular method and 3 menstrual cycles using the method of their allocated group. Overall satisfaction; secondary outcomes included discomfort, urovaginal infection, cost, and waste. Forty-seven women in each group completed the final survey, 5 of whom were subsequently excluded from analysis (3 from the tampon group and 2 from the menstrual cup group). Overall satisfaction on a 7-point Likert scale was higher for the menstrual cup group than for the tampon group (mean [standard deviation] score 5.4 [1.5] vs 5.0 [1.0], respectively; P=.04). Approximately 91% of women in the menstrual cup group said they would continue to use the cup and recommend it to others. Women used a median of 13 menstrual products per cycle, or 169 products per year, which corresponds to approximately 771,248,400 products used annually in Canada. Estimated cost for tampon use was $37.44 a year (similar to the retail cost of 1 menstrual cup). Subjective vaginal discomfort was initially higher in the menstrual cup group, but the discomfort decreased with continued use. There was no significant difference in physician-diagnosed urovaginal symptoms between the 2 groups. Both of the menstrual management methods evaluated were well tolerated by subjects. Menstrual cups are a satisfactory alternative to tampons and have the potential to be a sustainable solution to menstrual management, with moderate cost savings and much-reduced environmental effects compared with tampons. Trial registration number C06-0478 (ClinicalTrials.gov).

  7. Prediction of specialty coffee cup quality based on near infrared spectra of green coffee beans.

    Science.gov (United States)

    Tolessa, Kassaye; Rademaker, Michael; De Baets, Bernard; Boeckx, Pascal

    2016-04-01

    The growing global demand for specialty coffee increases the need for improved coffee quality assessment methods. Green bean coffee quality analysis is usually carried out by physical (e.g. black beans, immature beans) and cup quality (e.g. acidity, flavour) evaluation. However, these evaluation methods are subjective, costly, time consuming, require sample preparation and may end up in poor grading systems. This calls for the development of a rapid, low-cost, reliable and reproducible analytical method to evaluate coffee quality attributes and eventually chemical compounds of interest (e.g. chlorogenic acid) in coffee beans. The aim of this study was to develop a model able to predict coffee cup quality based on NIR spectra of green coffee beans. NIR spectra of 86 samples of green Arabica beans of varying quality were analysed. Partial least squares (PLS) regression method was used to develop a model correlating spectral data to cupping score data (cup quality). The selected PLS model had a good predictive power for total specialty cup quality and its individual quality attributes (overall cup preference, acidity, body and aftertaste) showing a high correlation coefficient with r-values of 90, 90,78, 72 and 72, respectively, between measured and predicted cupping scores for 20 out of 86 samples. The corresponding root mean square error of prediction (RMSEP) was 1.04, 0.22, 0.27, 0.24 and 0.27 for total specialty cup quality, overall cup preference, acidity, body and aftertaste, respectively. The results obtained suggest that NIR spectra of green coffee beans are a promising tool for fast and accurate prediction of coffee quality and for classifying green coffee beans into different specialty grades. However, the model should be further tested for coffee samples from different regions in Ethiopia and test if one generic or region-specific model should be developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. 75 FR 29889 - Special Local Regulation for Marine Event; 2010 International Cup Regatta, Pasquotank River...

    Science.gov (United States)

    2010-05-28

    ...-AA08 Special Local Regulation for Marine Event; 2010 International Cup Regatta, Pasquotank River... traffic in a portion of the Pasquotank River, near Elizabeth City, NC, during the 2010 International Cup... event in 33 CFR 100.501 and 33 CFR Table to Sec. 100.501, No. 54. On June 5 and 6, 2010, Carolina Cup...

  9. 77 FR 14423 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items, and Packaging Thereof; Notice...

    Science.gov (United States)

    2012-03-09

    ... INTERNATIONAL TRADE COMMISSION [DN 2883] Certain Food Containers, Cups, Plates, Cutlery, and... Containers, Cups, Plates, Cutlery, and Related Items, and Packaging Thereof, DN 2883; the Commission is... importation of certain food containers, cups, plates, cutlery, and related items, and packaging thereof. The...

  10. Fixation strength analysis of cup to bone material using finite element simulation

    NARCIS (Netherlands)

    Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; Van Der Heide, Emile

    2016-01-01

    Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw

  11. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    International Nuclear Information System (INIS)

    Zeren, J.D.

    1993-01-01

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet. 5 figures

  12. Analysis of world biathlon leaders’ participation in biathlon World Cup (on example of women’s biathlon

    Directory of Open Access Journals (Sweden)

    R.A. Zubrilov

    2015-11-01

    Full Text Available Purpose: optimization of elite female biathlons’ training, considering modern structure of international competitions. Material: we analyzed materials of three recent IBU Congresses and more than 3300 protocols of competitions of World cup stages, world championships, winter Olympic Games (women, sport seasons from 2005 to 2015. Results: it was found that, when preparing for winter Olympic Games 63.9% of sportsmen - prize winners missed 13.6% of stages of World Cup, when preparing for world championships 47.2% of prize-winners missed 9.5% of stages. Before the main start of the season in Europe prize winners missed in conditions of plain: 42.1% - 7.9% of World Cup stages; in midlands conditions 61.9% - 13.9%; in competitions with preliminary trans-meridian travel 54.2% of prize-winners missed 13.1% of stages. Conclusions: most of medals are won at world championships and Olympic Games by sportswomen, who are in top-10 of World Cup. The World Cup calendar of events forces sportsmen to miss some stages of World Cup, when they prepare to main start of season. Attitude of world biathlon leaders to missing of World Cup stages before main start of season depends on main character of main start of season. With it main condition for taking decision about missing of World Cup stages is rank of competitions and geographical characteristics of places of competitions.

  13. Closed suction drainage using Lichtenstein technique in preventing wound complications following inguinal hernioplasty: brief report

    Directory of Open Access Journals (Sweden)

    Hamid Reza Hemmati

    2015-03-01

    Results: No adverse event including hematoma, seroma or wound infection occurred in either group with or without closed suction drainage in the first 10 days after surgery. Only one patient carried wound infection during days 10 to 15 following operation who was in the group with closed drainage (P=1.00. Conclusion: In this study, Seroma and hematoma was not observed in patients with and without closed suction drainage. To avoid drains' complications, indiscriminate use of antibiotics, prolonged hospital stay, we do not recommend the use of drains in this type of surgery.

  14. Athletic Departments' Operating Expenses as a Predictor of Their Directors' Cup Standing

    Science.gov (United States)

    Magner, Amber

    2014-01-01

    The NACDA Directors' Cup is a competition utilizing an unbiased scoring system that encourages a broad based athletic department as the standard for defining intercollegiate athletic success. Therefore, for NCAA DI athletic administrators the Directors' Cup should be the standard for defining intercollegiate athletic success. The purpose of this…

  15. The effect of elevated die temperature on deformation of deep drawn round metal cup

    Science.gov (United States)

    Basril, M. A. M.; Hafsyam, Y. M.; Azuddin, M.; Choudhury, I. A.

    2017-06-01

    One of the major considerations in the current deep drawing practice is the product quality. In this research, the effect of heating temperature on the drawability of the round metal cup has been investigated. Firstly, round metal cups of aluminium and mild steel were drawn from the blank diameters of 60 mm, 65 mm and 70 mm. The experiment conducted at room temperature first, then at 50°C and 100°C. The elongation of the major and minor strains along the cup profile after the process is measured and analysed. On the other hand, the defects from the experiment output and ABAQUS/CAE simulation are compared. The result from experiment shows that the highest major elongation is 11.64 mm and it is happened to a deep drawn aluminium round cup with LDR of 1.69 at temperature of 100°C. On the other hand, for deep drawn mild steel round cup, shows highest major elongation of 12.44 mm for a cup with LDR of 1.56 at 100°C. Both of these statements indicates that the higher temperature could improve the formability of the deep drawn parts besides reducing the probability of the defect to be happened.

  16. Outcomes of cup revision for ilio-psoas impingement after total hip arthroplasty: Retrospective study of 46 patients.

    Science.gov (United States)

    Batailler, C; Bonin, N; M Wettstein; Nogier, A; Martres, S; Ollier, E; May, O; Lustig, S

    2017-12-01

    Impingement of the ilio-psoas tendon on the acetabular component is a cause of pain after total hip arthroplasty (THA). Studies of cup revision for ilio-psoas impingement (IPI) are scarce and limited in size. We therefore conducted a large multicentre retrospective study with the following objectives: to assess the effectiveness of cup replacement in resolving the impingement syndrome, to determine the frequency and nature of complications after cup revision for IPI, and to identify pre-operative factors associated with good outcomes of cup revision for IPI. Cup revision is effective in resolving the pain due to IPI in selected patients. This retrospective multicentre study included 46 patients who underwent cup revision because of IPI. Before the revision, 38 (83%) patients had prominence of the anterior cup rim (mean, 9.9±4.5mm (range, 2-22mm) by radiography and 35 (76%) had cup malposition (anteversion50°). Mean follow-up was 21months (range, 6months to 6 years) and no patient was lost to follow-up. Outcomes at last follow-up were assessed based on the Oxford Hip Score (OHS), patient satisfaction index, complications, and revisions. At last follow-up, 39 (85%) patients were satisfied with the revision procedure, a significant improvement versus baseline was noted in the OHS (mean, 43±6; range, 25-48; P<0.001), and 41 patients were free of pain during hip flexion (P<0.001 versus baseline). Complications occurred in 3 (6.5%) patients, but only one complication was severe (deep infection). Recurrent groin pain was reported by 4 (8.7%) patients at last follow-up. None of the factors studied predicted the outcome of revision surgery. Cup revision for IPI after THA is effective in relieving the groin pain in 80% of patients with anterior cup rim prominence and/or cup malposition. However, complications can occur. Tenotomy may be preferable when the diagnosis is in doubt and/or cup position is acceptable. IV, retrospective observational study. Published by Elsevier

  17. Canonical Wnt/β-catenin signalling is essential for optic cup formation.

    Directory of Open Access Journals (Sweden)

    Anna-Carin Hägglund

    Full Text Available A multitude of signalling pathways are involved in the process of forming an eye. Here we demonstrate that β-catenin is essential for eye development as inactivation of β-catenin prior to cellular specification in the optic vesicle caused anophthalmia in mice. By achieving this early and tissue-specific β-catenin inactivation we find that retinal pigment epithelium (RPE commitment was blocked and eye development was arrested prior to optic cup formation due to a loss of canonical Wnt signalling in the dorsal optic vesicle. Thus, these results show that Wnt/β-catenin signalling is required earlier and play a more central role in eye development than previous studies have indicated. In our genetic model system a few RPE cells could escape β-catenin inactivation leading to the formation of a small optic rudiment. The optic rudiment contained several neural retinal cell classes surrounded by an RPE. Unlike the RPE cells, the neural retinal cells could be β-catenin-negative revealing that differentiation of the neural retinal cell classes is β-catenin-independent. Moreover, although dorsoventral patterning is initiated in the mutant optic vesicle, the neural retinal cells in the optic rudiment displayed almost exclusively ventral identity. Thus, β-catenin is required for optic cup formation, commitment to RPE cells and maintenance of dorsal identity of the retina.

  18. Measuring splash erosion potential under vegetation using sand-filled splash cups

    Science.gov (United States)

    Geißler, C.; Scholten, T.; Kühn, P.

    2009-04-01

    In soil erosion research it is widely accepted that vegetation is not only protecting the soil from the erosive power of rainfall. Under specific circumstances (like they occur e.g. in forests) vegetation can enhance the erosive power of rainfall by modifying its properties (esp. drop size distribution, kinetic energy). The adjacent processes are very complex and variable in time and space and depend on numerous variables (e.g. rainfall intensity, drop size distribution, drop fall velocity, height of the canopy, density of the canopy, crown and leaf traits, LAI). In the last decades a large number of studies focused this process-system using different methods and came to often different results (Brandt 1989; Calder 2001; Foot & Morgan 2005; Hall & Calder 1993; Mosley 1982; Nanko et al. 2006; Park & Cameron 2008; Vis 1986). The main objective of our field experiments in subtropical China is to quantify the modification of precipitation by its pass through the canopy layer for six different tree species, three different successional stages and three different biodiversity classes. For this, new splash cups were developed based on the archetype of Ellison (1947). In contrast to previous studies with splash cups (Vis 1986) or other forms of splash cups (Kinnell 1974; Morgan 1981) we measured the unit sand remaining inside the cup after single natural rainfall events. The new splash cups contain of a PE-flask to which a carrier system has been attached. In this carrier system a cup filled with unit sand of 125-200 µm particle size is inserted. At the bottom of the cup a silk cover is attached to avoid the loss of sand and to guarantee free drainage of water from the cup to the carrier and vice versa. Cup and PE-flask are hydraulically connected by a cotton wick to assure constant moisture content throughout the time of measuring. Additionally, vents in the carrier system ensure that the pressure arising from the insertion of the cup doesn't lead to a loss of sand. The

  19. Recirculation pump suction line 2.8% break integral test at ROSA-III with HPCS failure, RUN 984

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Anoda, Yoshinari; Tasaka, Kanji; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Murata, Hideo; Shiba, Masayoshi

    1984-06-01

    This report presents the experimental data of 2.8% suction line break test RUN 984 at ROSA-III, which was conducted as one of counterpart tests to FIST program sponsored by GE, EPRI and USNRC. The similarity study between the ROSA-III and FIST tests is on the way. The report also presents the information on the ROSA-III test facility, experiment results and the effects of the ADS flow rate and the MSIV trip level comparing with the previously conducted ROSA-III small break tests, RUNs 920 and 922. Major conclusions obtained are as follows. (1) Change of the MSIV trip level from L2 to L1 gives delay of MSIV closure and longer actuation of pressure control system in a small break LOCA. (2) Larger ADS flow gives faster depressurization rate and earlier ECCS actuation, which results in shorter fuel rod dryout period and lower PCT. (author)

  20. Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    2017-01-01

    in measuring bone density (BMD) in complex anatomic structures which might be overcome using dual-energy computed tomography (DECT).PurposeTo test inter- and intra-observer agreement and reliability of in-house segmentation software measuring BMD adjacent to acetabular cup and to compare measurements performed...... with single-energy CT (SECT) and DECT in cemented and cementless cups.Material and Methods: Twenty-four acetabular cups inserted in porcine hip specimens were scanned with SECT and DECT. Bone density was measured in a three-dimensional volume adjacent to the cup. Double measurements were performed.......Results: BMD derived from SECT was approximately four times higher than that of DECT. In both scan modes, intraclass correlation coefficient (ICC) was >0.90 with no differences between repeated measurements, except for uncemented cups where a statistically significant difference of 11 mg/cm3 was found...

  1. Systematic review and meta-analysis of closed suction drainage versus non-drainage in primary hip arthroplasty.

    LENUS (Irish Health Repository)

    Kelly, Enda G

    2014-03-01

    The routine use of drains in surgery has been dogmatically instituted in some disciplines. Orthopaedic surgery is one such sub-speciality. The use of postoperative closed suction drainage in total hip arthroplasty (THA) has become increasingly controversial with multiple randomised control trials performed to assess the benefit to outcome in THA. The hypothesis of this systematic review is that closed suction drainage does not infer a benefit and increase transfusion requirements of primary total hip arthroplasty patients. A systematic review and meta-analysis was conducted adhering to the PRISMA guidelines. A search of the available literature was performed on PubMed, Cochrane Central Registry of Controlled Trials, MEDLINE (OVID) and EMBASE using a combination of MeSH terms and Boolean operators. All data analysis was performed using the Cochrane Collaboration\\'s Review Manager 5.1. Sixteen studies (n=2705) were included in the analysis. Post-operative closed suction drainage was found to increase total blood loss and blood transfusion requirements (p<0.05). Surgical site infection demonstrated no significant difference between the two groups (p=0.82). No significant difference in haematoma formation between groups (p=0.19) was elicited. The routine use of closed suction drainage systems post primary hip arthroplasty is not supported by this meta-analysis. However, the heterogeneity between studies does limit the accuracy of the meta-analysis.

  2. Cup anemometer response to the wind turbulence-measurement of the horizontal wind variance

    Directory of Open Access Journals (Sweden)

    S. Yahaya

    2004-11-01

    Full Text Available This paper presents some dynamic characteristics of an opto-electronic cup anemometer model in relation to its response to the wind turbulence. It is based on experimental data of the natural wind turbulence measured both by an ultrasonic anemometer and two samples of the mentioned cup anemometer. The distance constants of the latter devices measured in a wind tunnel are in good agreement with those determined by the spectral analysis method proposed in this study. In addition, the study shows that the linear compensation of the cup anemometer response, beyond the cutoff frequency, is limited to a given frequency, characteristic of the device. Beyond this frequency, the compensation effectiveness relies mainly on the wind characteristics, particularly the direction variability and the horizontal turbulence intensity. Finally, this study demonstrates the potential of fast cup anemometers to measure some turbulence parameters (like wind variance with errors of the magnitude as those deriving from the mean speed measurements. This result proves that fast cup anemometers can be used to assess some turbulence parameters, especially for long-term measurements in severe climate conditions (icing, snowing or sandy storm weathers.

  3. SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Niu, Y; Becker, S; Mutaf, Y; Yu, C

    2016-01-01

    Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

  4. SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Y [Xcision Medical Systems LLC, Columbia, MD (United States); Becker, S; Mutaf, Y [University Maryland School of Medicine, Baltimore, MD (United States); Yu, C [Xcision Medical Systems LLC, Columbia, MD (United States); University Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

  5. Association between laboratory capacities and world-cup performance in Nordic combined.

    Science.gov (United States)

    Rasdal, Vegard; Fudel, Ronny; Kocbach, Jan; Moen, Frode; Ettema, Gertjan; Sandbakk, Øyvind

    2017-01-01

    Nordic combined (NC) is an Olympic winter-sport performed as a ski jumping (SJ) event followed by a cross-country (XC) pursuit race employing the skating style. To elucidate the associations between sport-specific laboratory capacities and SJ, XC skiing, and overall NC performance in a world-cup NC event. Twelve international world-cup NC athletes from 8 nations performed laboratory testing one day prior to participating in a world-cup NC event. Squat jumps and SJ imitations (IMIT) were performed on a three-dimensional force plate, whereas XC skiing-specific physiological characteristics were obtained from roller ski skating tests on a treadmill and an all-out double poling (DP) test. Finally, body composition was measured. Laboratory capacities were correlated against performance in SJ, 10-km XC skiing, and overall NC in the world-cup event. Multiple regression analysis was used to determine the best suited laboratory variables for predicting performance. Vertical IMIT velocity together with body-mass provided the best prediction for SJ performance (r2 = 0.70, pjump capacity while minimizing body-mass within the BMI limit set by FIS should be considered in the seasonal training of NC athletes.

  6. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    Science.gov (United States)

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Development and first experimental tests of Faraday cup array.

    Science.gov (United States)

    Prokůpek, J; Kaufman, J; Margarone, D; Krůs, M; Velyhan, A; Krása, J; Burris-Mog, T; Busold, S; Deppert, O; Cowan, T E; Korn, G

    2014-01-01

    A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry. This is a unique method for two-dimensional visualisation of ion currents from laser-generated plasmas. A technical description of the new type of Faraday cup is introduced along with an ad hoc data analysis procedure. Experimental results obtained during campaigns at the Petawatt High-Energy Laser for Heavy Ion Experiments (GSI, Darmstadt) and at the Prague Asterix Laser System (AS CR) are presented. Advantages and limitations of the used diagnostic system are discussed.

  8. Optimizing the physical conditioning of the NASCAR sprint cup pit crew athlete.

    Science.gov (United States)

    Ferguson, David P; Davis, Adam M; Lightfoot, J Timothy

    2015-03-01

    Stock car racing is the largest spectator sport in the United States. As a result, National Association for Stock Car Automobile Racing (NASCAR) Sprint Cup teams have begun to invest in strength and conditioning programs for their pit crew athletes. However, there is limited knowledge regarding the physical characteristics of elite NASCAR pit crew athletes, how the NASCAR Sprint Cup season affects basic physiological parameters such as body composition, and what is the most appropriate physical training program that meets the needs of a pit crew athlete. We conducted 3 experiments involving Sprint Cup motorsport athletes to determine predictors of success at the elite level, seasonal physiological changes, and appropriate physical training programs. Our results showed that hamstring flexibility (p = 0.015) and the score on the 2-tire front run test (p = 0.012) were significant predictors of NASCAR Sprint Cup Pit Crew athlete performance. Additionally, during the off season, pit crew athletes lost lean body mass, which did not return until the middle of the season. Therefore, a strength and conditioning program was developed to optimize pit crew athlete performance throughout the season. Implementation of this strength and conditioning program in 1 NASCAR Sprint Cup team demonstrated that pit crew athletes were able to prevent lean body mass loss and have increased muscle power output from the start of the season to the end of the season.

  9. Development of a standardised cup anemometer suited to wind energy applications. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dahlberg, J.Aa.; Gustavsson, J.; Ronsten, G. [Aeronautical Research Inst. of Sweden, Bromma (Sweden); Friis Pedersen, T.; Schmidt Paulsen, U. [Risoe National Laboratory, Roskilde (Denmark); Westermann, D. [German Wind Energy Inst., Wilhelmshaven (Germany)

    2002-05-01

    Errors associated with the measurements and interpretation of the measured wind speed are the major sources of uncertainties in power performance testing of wind turbines. Field comparisons of well calibrated anemometers of different types often show significant and not acceptable differences. The objective were to determine the optimum design for a cup anemometer which should be free from the design faults associated with all of the instruments currently commercially available. The objective were also to prepare a classification system for cup anemometers which will allow users of anemometry in the wind energy field to rank and select anemometers suited to specific required applications. The extensive experiments including tests in wind tunnels, of more than 500 anemometer configurations, fields tests and tests in laboratories together with the assessment and modelling work have helped to build up a thorough knowledge of the importance of different design parameters in terms of various behavioural effects. Influenced by trends from the international standardisation work, an early decision was made to focus on a vector, 3D, (angle-insensitive anemometer) cup-anemometer and to focus on conical cups since their sensitivity to vertical velocity components appeared to be less sensitive to the wind speed. The key measures taken to develop the new design consisted of an appropriate selection of the detailed design of the cup geometry's and mounting the cups at appropriate radius on a slender symmetric body. The development finally ended with an anemometer that gave a very good flat response within 1 % over the range from -45 deg to +35 deg and had a good linear calibration curve. Four prototypes of the anemometer optimised for flat response were produced. The flat response was also confirmed by field tests over the range {+-}20 deg. A patent application of the new anemometer was filed on the 6th of October 2000. By the time the project was initiated there was a

  10. Time-Resolved Tandem Faraday Cup Development for High Energy TNSA Particles

    Science.gov (United States)

    Padalino, S.; Simone, A.; Turner, E.; Ginnane, M. K.; Glisic, M.; Kousar, B.; Smith, A.; Sangster, C.; Regan, S.

    2015-11-01

    MTW and OMEGA EP Lasers at LLE utilize ultra-intense laser light to produce high-energy ion pulses through Target Normal Sheath Acceleration (TNSA). A Time Resolved Tandem Faraday Cup (TRTF) was designed and built to collect and differentiate protons from heavy ions (HI) produced during TNSA. The TRTF includes a replaceable thickness absorber capable of stopping a range of user-selectable HI emitted from TNSA plasma. HI stop within the primary cup, while less massive particles continue through and deposit their remaining charge in the secondary cup, releasing secondary electrons in the process. The time-resolved beam current generated in each cup will be measured on a fast storage scope in multiple channels. A charge-exchange foil at the TRTF entrance modifies the charge state distribution of HI to a known distribution. Using this distribution and the time of flight of the HI, the total HI current can be determined. Initial tests of the TRTF have been made using a proton beam produced by SUNY Geneseo's 1.7 MV Pelletron accelerator. A substantial reduction in secondary electron production, from 70% of the proton beam current at 2MeV down to 0.7%, was achieved by installing a pair of dipole magnet deflectors which successfully returned the electrons to the cups in the TRTF. Ultimately the TRTF will be used to normalize a variety of nuclear physics cross sections and stopping power measurements. Based in part upon work supported by a DOE NNSA Award#DE-NA0001944.

  11. Heat Transfer in a Paper Cup

    Science.gov (United States)

    Ribeiro, Carla

    2017-01-01

    The double-wall paper cup is an everyday object that can be used in the laboratory to study heat transfer. The experiment described here has been done by physics students aged 12-13 years; it can also be used in a different context to prompt debate about environmental issues.

  12. [Pain assessment of tracheal suctioning on brain injury patients by pain behavioral indicator scale (ESCID)].

    Science.gov (United States)

    López-López, C; Murillo-Pérez, M A; Morales-Sánchez, C; Torrente-Vela, S; Orejana-Martín, M; García-Iglesias, M; Cuenca-Solanas, M; Alted-López, E

    2014-01-01

    To assess pain response on patients with moderate to severe head injury before a common nursing procedure: tracheal suctioning. An observational longitudinal pilot study with consecutive sampling performed from September to December of 2012. Pain was assessed by a pain behavioral indicator scale 5 minutes before, meanwhile and 15 minutes after tracheal suctioning the days 1, 3 and 6 of their intensive care unit (ICU) stay, as well as a non-painful procedure: rubbing with gauze the forearm of the patient. Pseudo-analgesia and hemodynamic variables were also recorded. Descriptive analysis of the variables, inferential statistics with t-student and Anova with SPSS 17.0; statistical tests were considered significant if the critical level observed was less than 5% (P.05) were shown. Data for the painless procedure were significantly different on day 6 (P<.05) CONCLUSION: During tracheal suctioning in patients with head injury in the first 6 days in the ICU, objective mild-moderate pain according to ESCID scale has been detected. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  13. Mode of action of cupping--local metabolism and pain thresholds in neck pain patients and healthy subjects.

    Science.gov (United States)

    Emerich, M; Braeunig, M; Clement, H W; Lüdtke, R; Huber, R

    2014-02-01

    Cupping worldwide has been part of traditional medicine systems and is in the western world used as CAM therapy mainly for treating pain syndromes. The mode of action is up to now unclear. In order to investigate its mechanism we measured in parallel metabolic changes in the tissue under the cupping glass and pressure pain thresholds. In 12 volunteers (6 healthy subjects and 6 patients with chronic neck pain) a microdialysis system was implanted subcutaneously on both sides (left and right) above the trapezius muscle. After baseline measures cupping was performed at one randomly selected side (left or right), the other side served as control. Every 20 min during baseline measures and for 280 min after cupping, microdialysis probes for detection of lactate, pyruvate, glucose and glycerin were taken. In addition, pain thresholds were measured before and after cupping with algometry. Cupping resulted in a strong increase of lactate (beginning 160 min after cupping until the end of the measurements) and the lactate/pyruvate ratio, indicating an anaerobe metabolism in the surrounding tissue. Baseline pain thresholds were non-significantly lower in neck pain patients compared to healthy controls and slightly increased immediately after cupping (pcupping in healthy subjects and on the foot in neck pain patients). After 280 min no more significant changes of pain thresholds were detected. Cupping induces >280 min lasting anaerobe metabolism in the subcutaneous tissue and increases immediate pressure pain thresholds in some areas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Early migration characteristics of a 180° porous-coated cup with 1-mm press fit.

    Science.gov (United States)

    Stihsen, Christoph; Rath, Christopher; Radl, Roman; Saalabian, Ali A; Materna, Wilfried; Rehak, Peter; Windhager, Reinhard

    2013-05-01

    Evaluation of early cup movement is an important diagnostic tool to predict the likelihood of long-term implant loosening and clinical failure. The investigated cementless cup is clinically proven over 10 years, but there is a paucity of information that accurately describes the migration characteristics of this component. We retrospectively analysed the clinical outcome and migration behaviour of 60 Pinnacle 100 shells after an average 3.8-year follow-up (range 2.1-5.4 years). For migration measurement, EBRA (Einzel-Bild-Röntgen-Analyse) digital software was applied. Clinical assessment was performed using the HHS, the UCLA score and the SF-36 health survey. The clinical outcome showed excellent results with a mean HHS of 95.4 (SD 7.1) and mean UCLA of 6.9 (SD 1.3). All implants were radiologically stable within the observation period and none of the cups was at risk for aseptical loosening. EBRA analysis revealed a mean total migration of 1.4 mm (SD 0.9) (95 % CI 1.1-1.6) at 3 years. Eight cups migrated more than 1 mm within the first three postoperative months, thereafter the migration curves flattened down. Surgeons may expect to find a variable amount of early migration when using the Pinnacle cup. To our knowledge, these are the first results, which show an early "impaction" of a cementless cup, followed by subsequent osseointegration. We believe that an appropriate long-term outcome of the investigated cup is ensured. The data of the present investigation will provide clinicians with useful baseline information with which to compare new cup designs.

  15. Effects of Cupping Therapy in Amateur and Professional Athletes: Systematic Review of Randomized Controlled Trials.

    Science.gov (United States)

    Bridgett, Rhianna; Klose, Petra; Duffield, Rob; Mydock, Suni; Lauche, Romy

    2018-03-01

    Despite the recent re-emergence of the process of cupping by athletes, supporting evidence for its efficacy and safety remains scarce. This systematic review aims to summarize the evidence of clinical trials on cupping for athletes. SCOPUS, Cochrane Library, PubMed, AMED, and CNKI databases were searched from their inception to December 10, 2016. Randomized controlled trials on cupping therapy with no restriction regarding the technique, or cointerventions, were included, if they measured the effects of cupping compared with any other intervention on health and performance outcomes in professionals, semi-professionals, and leisure athletes. Data extraction and risk of bias assessment using the Cochrane Risk of Bias Tool were conducted independently by two pairs of reviewers. Eleven trials with n = 498 participants from China, the United States, Greece, Iran, and the United Arab Emirates were included, reporting effects on different populations, including soccer, football, and handball players, swimmers, gymnasts, and track and field athletes of both amateur and professional nature. Cupping was applied between 1 and 20 times, in daily or weekly intervals, alone or in combination with, for example, acupuncture. Outcomes varied greatly from symptom intensity, recovery measures, functional measures, serum markers, and experimental outcomes. Cupping was reported as beneficial for perceptions of pain and disability, increased range of motion, and reductions in creatine kinase when compared to mostly untreated control groups. The majority of trials had an unclear or high risk of bias. None of the studies reported safety. No explicit recommendation for or against the use of cupping for athletes can be made. More studies are necessary for conclusive judgment on the efficacy and safety of cupping in athletes.

  16. Microindentation hardness evaluation of iridium alloy clad vent set cups

    International Nuclear Information System (INIS)

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1993-01-01

    An iridium alloy, DOP-26, is used as cladding for 238 PuO 2 fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors

  17. Microindentation hardness evaluation of iridium alloy clad vent set cups

    International Nuclear Information System (INIS)

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1992-01-01

    An iridium alloy, DOP-26, is used as cladding for 238 PuO 2 fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors

  18. The radontechnical process of the sub-slab suction system in detached, semi-detached and terraced houses; Imupistejaerjestelmaen radontekninen toiminta eri tyyppisissae pien- ja rivitaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Kettunen, A.V.; Rissanen, R.; Viljanen, M. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Structural Engineering and Building Physics; Arvela, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    The sub-slab suction system is a repair method for decreasing radon transfer from soil to indoor air in houses. The sub-slab suction system changes the flow field with the aim to reduce the radon content under the ground slab or/and changes the flow direction from indoor air to foundation soil. The study is divided into the theoretical and experimental part. The theoretical part concentrates on solving the factors affecting the sub-slab suction system taking into consideration features of old houses. The experimental part uses the results of the theoretical part when the level and the type of the suction point had been chosen. The effect of the sub-slab suction system was tested with pressure difference experiments and the radon content measurements in 26 different, typical Finnish detached, semi-detached and terrace houses.

  19. 78 FR 40396 - Safety Zone; America's Cup Safety Zone and No Loitering Area, San Francisco, CA

    Science.gov (United States)

    2013-07-05

    ...-AA00 Safety Zone; America's Cup Safety Zone and No Loitering Area, San Francisco, CA AGENCY: Coast... America's Cup races. This safety zone and no loitering area are established to enhance the safety of spectators and mariners near the north east corner of the America's Cup regulated area. All persons or...

  20. Suction Cup Induced Palatal Fistula: Surgical Closure by Palatal ...

    African Journals Online (AJOL)

    1Department of Pediatrics, Pragna Children's Hospital, Hyderabad, ... Eluru, 4Department of Conservative Dentistry and Endodontics, KIMS Dental College and ... The surgical closure of palatal fistula planned under general anesthesia.

  1. Suction/inspiration against resistance or standardized Mueller maneuver: a new breathing technique to improve contrast density within the pulmonary artery: a pilot CT study

    Energy Technology Data Exchange (ETDEWEB)

    Gutzeit, Andreas [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland); Kantonsspital Winterthur, Department of Radiology, Winterthur (Switzerland); Froehlich, Johannes M.; Weymarn, Constantin von; Goyen, Matthias [Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland); Waelti, Stephan [Cantonal Hospital St. Gallen, Department of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Roos, Justus E. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Meissnitzer, Matthias; Hergan, Klaus [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Czell, David [Cantonal Hospital Winterthur, Department of Neurology, Winterthur (Switzerland); Reischauer, Carolin [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland)

    2015-11-15

    Our aim was to prospectively investigate whether the recently introduced suction/inspiration against resistance breathing method leads to higher computed tomography (CT) contrast density in the pulmonary artery compared to standard breathing. The present study was approved by the Medical Ethics committee and all subjects gave written informed consent. Fifteen patients, each without suspicious lung emboli, were randomly assigned to four different groups with different breathing maneuvers (suction against resistance, Valsalva, inspiration, expiration) during routine CT. Contrast enhancement in the central and peripheral sections of the pulmonary artery were measured and compared with one another. Peripheral enhancement during suction yielded increased mean densities of 138.14 Hounsfield units (HU) (p = 0.001), compared to Valsalva and a mean density of 67.97 HU superior to inspiration (p = 0.075). Finally, suction in comparison to expiration resulted in a mean increase of 30.51 HU (p = 0.42). Central parts of pulmonary arteries presented significantly increased enhancement values (95.74 HU) for suction versus the Valsalva technique (p = 0.020), while all other mean densities were in favour of suction (versus inspiration: p = 0.201; versus expiration: p = 0.790) without reaching significance. Suction/Inspiration against resistance is a promising technique to improve contrast density within pulmonary vessels, especially in the peripheral parts, in comparison to other breathing maneuvers. (orig.)

  2. Effect of palady and cup feeding on premature neonates′ weight gain and reaching full oral feeding time interval

    Directory of Open Access Journals (Sweden)

    Maryam Marofi

    2016-01-01

    Full Text Available Background: Premature neonates′ feeding is of great importance due to its effective role in their growth. These neonates should reach an independent oral nutrition stage before being discharged from the Neonatal Intensive care Unit. Therefore, the researcher decided to conduct a study on the effect of palady and cup feeding on premature neonates′ weight gain and their reaching full oral feeding time interval. Materials and Methods: This is a clinical trial with a quantitative design conducted on 69 premature infants (gestational age between 29 and 32 weeks who were assigned to cup (n = 34 and palady (n = 35 feeding groups through random allocation. The first feeding was administrated either by cup or palady method in each shift within seven sequential days (total of 21 cup and palady feedings. Then, the rest of feeding was administrated by gavage. Results: Mean hospitalization time (cup = 39.01 and palady = 30.4; P < 0.001 and mean time interval to reach full oral feeding (cup = 33.7 and palady = 24.1; P < 0.001 were significantly lower in palady group compared to cup group. Mean weight changes of neonates 7 weeks after the intervention compared to those in the beginning of the intervention were significantly more in palady group compared to the cup group (cup = 146.7 and palady = 198.8; P < 0.001. Conclusions: The neonates in palady group reached full oral feeding earlier than those of cup group. Subjects′ weight gain was also higher in palady group compared to the cup group. Premature neonates with over 30 weeks of gestational age and physiological stability can be fed by palady.

  3. The Effects of Dry Cupping Therapy on the Shoulder Pain and Fatigue of Nurses

    Directory of Open Access Journals (Sweden)

    Dorina Sohn

    2011-06-01

    Full Text Available Objective: This research was done to identify the effects of dry cupping therapy on the shoulder pain and fatigue of nurses. Methods: The research design was time series design. The participants were 27 nurses with shoulder pain at P University Hospital in Busan metropolitan city from July 6, 2009 to August 3, 2009. The dry cupping therapy was done 4 times, twice a week for 2 weeks. Before intervention, the severity and frequency of pain and fatigue were measured three times at one week intervals, and then those were measured after one week and two weeks of experimental treatment. The results were analyzed using descriptive statistics, paired t-test and repeated measure ANOVA with the SPSS program. Results: There were statistically significant difference in severity and frequency of shoulder pain,and fatigue after dry cupping therapy. Dry cupping therapy was effective for the management of shoulder pain and fatigue among nurses in this study. Conclusion: Therefore dry cupping therapy can be considered an effective nursing intervention that relieves shoulder pain and fatigue of nurses.

  4. Construction of the Faraday Cup based on fluorescent screen as an electron beam sensor

    International Nuclear Information System (INIS)

    Sutadi; Rany Saptaaji; Suhartono; Sukaryono

    2016-01-01

    The Faraday Cup based on fluorescent screen as an electron beam profile sensor at electron accelerator has been conducted. In the principle, the electron beam which obtained from the electron source and accelerated in the accelerator tube will obtain the light which can be observed visually when it interact with fluorescent material (phosphorescent). This Faraday Cup for electron beam sensor was made from the modified TV tube. The main component of this Faraday Cup construction includes: 17 inch TV tube, SS reducer flange and the vacuum adhesive. There are two kind of test has been conducted, that is the vacuum level test and the electron beam sensor test. The vacuum level test was conducted by measuring the final vacuum level that can be reach, while the electron beam sensor test was conducted by monitoring of the electron beam profile that was trapped by Faraday Cup visually. The test result shows that TV tube can be modified as the Faraday Cup to sensor electron beam in the electron accelerator. (author)

  5. Air suctioning during colon biopsy forceps removal reduces bacterial air contamination in the endoscopy suite.

    Science.gov (United States)

    Vavricka, S R; Tutuian, R; Imhof, A; Wildi, S; Gubler, C; Fruehauf, H; Ruef, C; Schoepfer, A M; Fried, M

    2010-09-01

    Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination. This was a prospective single-blinded trial involving 50 patients who were undergoing elective nontherapeutic colonoscopy. During colonoscopy, endoscopists removed the biopsy forceps first without and then with suctioning following contact with the sigmoid mucosa. A total of 50 L of air was collected continuously for 30 seconds at 30-cm distance from the biopsy channel valve of the colonoscope, with time starting at forceps removal. Airborne bacteria were collected by an impactor air sampler (MAS-100). Standard Petri dishes with CNA blood agar were used to culture Gram-positive bacteria. Main outcome measure was the bacterial load in endoscopy room air. At the beginning and end of the daily colonoscopy program, the median (and interquartile [IQR] range) bioaerosol burden was 4 colony forming units (CFU)/m (3) (IQR 3 - 6) and 16 CFU/m (3) (IQR 13 - 18), respectively. Air suctioning during removal of the biopsy forceps reduced the bioaerosol burden from a median of 14 CFU/m (3) (IQR 11 - 29) to a median of 7 CFU/m (3) (IQR 4 - 16) ( P = 0.0001). Predominantly enterococci were identified on the agar plates. The bacterial aerosol burden during handling of biopsy forceps can be reduced by applying air suction while removing the forceps. This simple method may reduce transmission of infectious agents during gastrointestinal endoscopies. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  6. On Parameters Affecting Metal Flow and Friction in the Double Cup Extrusion Test

    DEFF Research Database (Denmark)

    Tan, Xincai; Bay, Niels; Zhang, Wenqi

    1998-01-01

    in numerical simulations often involve strain hardening because friction is expressed as a function of the flow stress or the flow shear stress. The double cup extrusion test is considered to be one of the process tests for determination of friction. In this test, varying heights of the upper and lower cups...... model with constant absolute value excluding the influence of strain hardening on friction was adopted in FEM simulations, in order to more clearly study the individual influence of strain hardening and friction on the metal flow (upper and lower cup height ratio) without interference between the two...... parameters. The predicted results show a good agreement with the experimental data. The influence of material strain hardening. friction and tool geometry on the metal flow in the test has been investigated. By comparisons of the cup height ratio as a function of the punch travel estimated by experiments...

  7. [Efficacy comparison between needle-knife therapy and acupuncture-cupping for cervical spondylosis of cervical type].

    Science.gov (United States)

    Cao, Li; Wang, Fan

    2014-05-01

    To compare the efficacy differences between needle-knife therapy and acupuncture-cupping for treatment of cervical spondylosis (CS) of cervical type. Sixty cases of CS were randomly divided into a needle-knife group (30 cases) and an acupuncture-cupping group (30 cases). The needle-knife therapy was applied at points among superior nuchal line of occipital bone, bilateral neck muscle, neck centerline, trapezius and medial border scapula for only once. In the acupuncture-cupping group, acupuncture was applied at Fengchi (GB 20), Fengfu (GV 16), Tianzhu (BL 10), Dazhui (GV 14), Jianjing (GB 21), Jiaji (Ex-B2, from C4 to C6), Houxi (SI 3) and Ashi point, followed by cupping on local skin, once every other day for totally six times. The score of neck stiffness and visual analogue scale (VAS) were observed before and after treatment, in follow-up of 1, 3 and 6 months after treatment in the two groups, and the efficacy was compared. In the needle-knife group, 9 cases were cured, 12 cases were markedly effective, 8 cases were effective and 1 case was failed; the total effective rate was 96.7% (29/30) and the cured and markedly effective rate was 70.0% (21/30). In the acupuncture-cupping group, 8 cases were cured, 9 cases were markedly effective, 11 cases were effective and 2 cases were failed; the total effective rate was 93.3% (28/30) and the cured and markedly effective rate was 56.7% (17/30). The difference of total effective rate in the two groups was not statistically significant (P > 0.05), but the cured and markedly effective rate of needle-knife group was significantly superior to that of acupuncture-cupping group (P therapy was significantly superior to acupuncture-cupping on improvement of neck stiffness in the follow-up of 1, 3, 6 months after treatment (P cupping group (both P therapy has better effects on neck stiffness and pain relief than acupuncture-cupping, and it is more treatment time saving.

  8. comparative measurement o river for small hydro tive measurement

    African Journals Online (AJOL)

    eobe

    Keywords: Keywords: small hydropower, electric power, volum ... gathering systems. .... or revolving cups connected to the end. ..... Also, the float velocity may have been affected by wind ... completely dedicated as off-grid supply can meet the.

  9. Laboratory determined suction potential of Topopah Spring tuff at high temperatures

    International Nuclear Information System (INIS)

    Daily, W.; Lin, Wunan.

    1991-01-01

    The purpose of this work is to experimentally determine the capillary suction potential of Topopah Spring tuff from Yucca Mountain, Nye County, Nevada. This data can be used to help characterize the unsaturated hydraulic properties of the densely welded tuff at this site. 7 refs., 4 figs., 1 tab

  10. Instruction Workbook for Tracheostomy Suctioning and Misting in a School Setting.

    Science.gov (United States)

    Wolf, Karen McKinney; Roach, Antionette Andolfatto

    The handbook presents California guidelines for training school personnel to provide skilled nursing procedures such as tracheostomy suctioning and misting for students with special health needs. The workbook begins with an overview of the anatomy and function of the respiratory system, specifically breathing mechanics. Part 2 considers the…

  11. Fast Faraday Cup With High Bandwidth

    Science.gov (United States)

    Deibele, Craig E [Knoxville, TN

    2006-03-14

    A circuit card stripline Fast Faraday cup quantitatively measures the picosecond time structure of a charged particle beam. The stripline configuration maintains signal integrity, and stitching of the stripline increases the bandwidth. A calibration procedure ensures the measurement of the absolute charge and time structure of the charged particle beam.

  12. Remora fish suction pad attachment is enhanced by spinule friction.

    Science.gov (United States)

    Beckert, Michael; Flammang, Brooke E; Nadler, Jason H

    2015-11-01

    The remora fishes are capable of adhering to a wide variety of natural and artificial marine substrates using a dorsal suction pad. The pad is made of serial parallel pectinated lamellae, which are homologous to the dorsal fin elements of other fishes. Small tooth-like projections of mineralized tissue from the dorsal pad lamella, known as spinules, are thought to increase the remora's resistance to slippage and thereby enhance friction to maintain attachment to a moving host. In this work, the geometry of the spinules and host topology as determined by micro-computed tomography and confocal microscope data, respectively, are combined in a friction model to estimate the spinule contribution to shear resistance. Model results are validated with natural and artificially created spinules and compared with previous remora pull-off experiments. It was found that spinule geometry plays an essential role in friction enhancement, especially at short spatial wavelengths in the host surface, and that spinule tip geometry is not correlated with lamellar position. Furthermore, comparisons with pull-off experiments suggest that spinules are primarily responsible for friction enhancement on rough host topologies such as shark skin. © 2015. Published by The Company of Biologists Ltd.

  13. Effect of Pelvic Tilt and Rotation on Cup Orientation in Both Supine and Standing Positions.

    Science.gov (United States)

    Yun, Hohyun; Murphy, William S; Ward, Daniel M; Zheng, Guoyan; Hayden, Brett L; Murphy, Stephen B

    2018-05-01

    The purpose of this study is to analyze the effect of pelvic tilt and rotation on radiographic measurement of cup orientation. A total of 68 patients (79 hips) were included in this study. The patients had a computed tomography study and approximately 3 months of postoperative standing anteroposterior pelvic radiographs in both supine and standing positions. We used 2-dimensional (2D)/3-dimensional (3D) matching to measure pelvic tilt and rotation, and cup orientation. There was a wide range of pelvic tilt between individuals in both supine and standing positions. Supine pelvic tilt was different from standing pelvic tilt (P cup anteversion before and after 2D/3D matching in both supine and standing positions (P cup anteversion before and after 2D/3D matching. When all 79 hips were separated into right and left side, pelvic rotation inversely correlated with the pelvic tilt-adjusted difference in anteversion before and after 2D/3D matching of the right side but directly correlated with that of the left side in both supine and standing positions. This study demonstrated that the measurement of cup anteversion on anteroposterior radiographs is significantly affected by both pelvic tilt and pelvic rotation (depending on the side). Improved understanding of pelvic orientation and improved ability to measure pelvic orientation may eventually allow for desired cup positioning to potentially protect against complications associated with malposition of the cup. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Effects of grazing strategy on limiting nitrate leaching in grazed grass-clover pastures on coarse sandy soil

    DEFF Research Database (Denmark)

    Hansen, Elly Møller; Eriksen, Jørgen; Søegaard, Karen

    2012-01-01

    -term mean. The experiment was initiated in a 4-yr-old grass-clover sward in south Denmark. Three treatments were as follows grazing only (G), spring cut followed by grazing (CG) and both spring and autumn cuts with summer grazing (CGC). Nitrate leaching was calculated by extracting water isolates from 80 cm......Urinations of ruminants on grazed pastures increase the risk of nitrate leaching. The study investigated the effect of reducing the length of the grazing season on nitrate leaching from a coarse sandy, irrigated soil during 2006–2007 and 2007–2008. In both years, precipitation was above the long...... depth using ceramic suction cups. Because of considerable variation in measured nitrate concentrations, the 32 installed suction cups per treatment were insufficient to reveal differences between treatments. However, weighted nitrate leaching estimations for G, CG and CGC showed estimated mean nitrate N...

  15. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    Science.gov (United States)

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  16. Investigation on paper cup waste degradation by bacterial consortium and Eudrillus eugeinea through vermicomposting.

    Science.gov (United States)

    Arumugam, Karthika; Renganathan, Seenivasagan; Babalola, Olubukola Oluranti; Muthunarayanan, Vasanthy

    2018-04-01

    Disposable Paper cups are a threat to the environment and are composed of 90% high strength paper with 5% thin coating of polyethylene. This polyethylene prevents the paper cup from undergoing degradation in the soil. Hence, in the present study two different approaches towards the management of paper cup waste through vermicomposting technology has been presented. The experimental setup includes 2 plastic reactors namely Vermicompost (VC) (Cow dung + Paper cup waste + Earthworm (Eudrillus eugeinea)) and Vermicompost with bacterial consortium (VCB) (Cow dung + Paper cup waste + Eudrillus eugeinea + Microbial consortia such as Bacillus anthracis, B. endophyticus, B. funiculus, B. thuringiensis, B. cereus, B. toyonensis, Virigibacillius chiquenigi, Acinetobacter baumanni and Lactobacillus pantheries). After treatment the physicochemical parameters were analysed. The results showed that the values of TOC (26.52 and 37.47%), TOM (36.01 and 33.13%) and C/N (15.02 and 11.92%) ratio are reduced in both VC and VCB whereas, the values of pH (8.01 and 7.56), EC (1.2-1.9 µs -1 and 1.4-1.9 µs -1 ), TP (46.1 and 51%), TMg (50.52 and 64.3%), TCa (50 and 64%), TNa (1.39 and 1.75%) and TK (1.75 and 1.86%) have increased. This study substantiates the addition of the microbial consortia augmenting the degradation in VCB reactor by reducing the period of process from 19 to 12 weeks. Further the characterisation of the vermicompost prepared from paper cup with FT-IR shows high degradation of carboxylic and aliphatic group; SEM analysis shows the disaggregation of cellulose and lignin; XRD shows the degradation of cellulose. All these analyses endorse the degradation of the paper cup waste faster with microbes (VCB). Thus, this present study high lights management of the paper cup waste in a relatively short period of time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Cervical spinal epidural abscess following acupuncture and wet-cupping therapy: A case report.

    Science.gov (United States)

    Yao, Yindan; Hong, Wenke; Chen, Huimin; Guan, Qiongfeng; Yu, Hu; Chang, Xianchao; Yu, Yaoping; Xu, Shanhu; Fan, Weinv

    2016-02-01

    Report of an uncommon complication of acupuncture and wet cupping. A 54-year-old man presented with neck pain and fever. Magnetic resonance imaging of the cervical spine revealed an epidural abscess at C4 to T2. The symptoms related to epidural abscess resolved partially after treatment with antibiotics. Acupuncture and wet-cupping therapy should be taken into consideration as a cause of spinal epidural abscesses in patients who present with neck pain and fever. Furthermore, acupuncture and wet-cupping practitioners should pay attention to hygienic measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Abdominal drainage following cholecystectomy: high, low, or no suction?

    OpenAIRE

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study f...

  19. [Combination of acupuncture, cupping and medicine for treatment of fibromyalgia syndrome: a multi-central randomized controlled trial].

    Science.gov (United States)

    Jang, Zhen-Ya; Li, Chang-Du; Qiu, Ling; Guo, Jun-Hua; He, Ling-Na; Yue, Yang; Li, Fang-Ze; Qin, Wen-Yi

    2010-04-01

    To evaluate the clinical effect of combination of acupuncture, cupping and medicine for treatment of fibromyalgia syndrome. By using multi-central randomized controlled method, 186 cases were randomly divided into an acupuncture combined with cupping and western medicine group (group A), an acupuncture combined with cupping group (group B) and a western medicine group (group C) and treated continuously for 4 weeks. The treatment of acupuncture combined with cupping was produced by acupuncture at five mental points and moving cupping on the Hechelu of the back, once evrey other day, thrice each week, and the western medicine therapy by oral administration of Amitriptyline, once each day. The scores of McGill Pain Questionnaire (MPQ), the amount of tenderness point and the time of producing effect were compared and the therapeutic effects were assessed with the Hamilton Depression Scale (HAMD). The cured and markedly effective rate was 65.0% (39/60) in the group A, which was superior to 15.9% (10/63) in the group B and 16.1% (9/56) in the group C (both P cupping and medicine on fibromyalgia syndrome is superior to that of the simple acupuncture combined with cupping or the simple medicine.

  20. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    Science.gov (United States)

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  1. Cancers of unknown primary origin (CUP) are characterized by chromosomal instability (CIN) compared to metastasis of know origin

    DEFF Research Database (Denmark)

    Vikeså, Jonas; Møller, Anne Kirstine H; Kaczkowski, Bogumil

    2015-01-01

    BACKGROUND: Cancers of unknown primary (CUPs) constitute ~5% of all cancers. The tumors have an aggressive biological and clinical behavior. The aim of the present study has been to uncover whether CUPs exhibit distinct molecular features compared to metastases of known origin. METHODS: Employing......RNA signatures of chromosome instability (CIN), indicating that CUPs are chromosome unstable compared to metastases of known origin. CONCLUSIONS: CIN may account for the uncommon clinical presentation, chemoresistance and poor outcome in patients with CUP and warrant selective diagnostic strategies and treatment....... genome wide transcriptome analysis, Linear Discriminant Analysis (LDA) and Quadratic Discriminant Analysis (QDA), we defined the putative origins of a large series of CUP and how closely related a particular CUP was to corresponding metastases of known origin. LDA predictions were subsequently used...

  2. Anaemia and skin pigmentation after excessive cupping therapy by an unqualified therapist in Korea: a case report.

    Science.gov (United States)

    Kim, Kun Hyung; Kim, Tae-Hun; Hwangbo, Min; Yang, Gi Young

    2012-09-01

    A case is reported of skin pigmentation and associated anemia resulting from persistently repeated cupping therapies performed by an unqualified practitioner in South Korea. Almost 30 sessions of excessive cupping therapies with blood loss over two months yielded little benefit but led the patient to admit a hospital and receive blood transfusion for acquired iron deficiency anemia. Skin pigmentation on the cupping-attached region remained without any subjective discomfort. We suggest the importance of qualified health professionals when receiving cupping treatments.

  3. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.; Seidman, D.N.

    1977-01-01

    A novel Faraday cup is described which allows the simultaneous observation and measurement of ion-beam currents. The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA), which serves as the basis of an internal image intensification system (a gain of >10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion current which is measured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30-keV Ar + ion beam is presented as an illustrative example. We have also employed this Faraday cup to observe and measure 30-keV Cr + , Mo + , or W + , and 18-keV Au + ion beams employed for the in situ irradiation of field-ion microscope specimens

  4. Fabricating Zr-Based Bulk Metallic Glass Microcomponent by Suction Casting Using Silicon Micromold

    Directory of Open Access Journals (Sweden)

    Zhijing Zhu

    2014-08-01

    Full Text Available A suction casting process for fabricating Zr55Cu30Al10Ni5 bulk metallic glass microcomponent using silicon micromold has been studied. A complicated BMG microgear with 50 μm in module has been cast successfully. Observed by scanning electron microscopy and laser scanning confocal microscopy, we find that the cast microgear duplicates the silicon micromold including the microstructure on the surface. The amorphous state of the microgear is confirmed by transmission election microscopy. The nanoindentation hardness and elasticity modulus of the microgear reach 6.5 GPa and 94.5 GPa. The simulation and experimental results prove that the suction casting process with the silicon micromold is a promising one-step method to fabricate bulk metallic glass microcomponents with high performance for applications in microelectromechanical system.

  5. Magnetohydrodynamics effect on three-dimensional viscous incompressible flow between two horizontal parallel porous plates and heat transfer with periodic injection/suction

    Directory of Open Access Journals (Sweden)

    R. C. Chaudhary

    2004-11-01

    Full Text Available We investigate the hydromagnetic effect on viscous incompressible flow between two horizontal parallel porous flat plates with transverse sinusoidal injection of the fluid at the stationary plate and its corresponding removal by periodic suction through the plate in uniform motion. The flow becomes three dimensional due to this injection/suction velocity. Approximate solutions are obtained for the flow field, the pressure, the skin-friction, the temperature field, and the rate of heat transfer. The dependence of solution on M (Hartmann number and λ (injection/suction is investigated by the graphs and tables.

  6. 78 FR 23908 - Marine Mammals; File No. 14809

    Science.gov (United States)

    2013-04-23

    ... and Southern Oceans. Methods to be used include suction cup tagging, acoustic playbacks, passive... macrocephalus), and southern right (Eubalaena australis) whales, as well as 31 cetacean species that are not... Scientific Advisors. Documents may be reviewed in the following locations: Permits and Conservation Division...

  7. Enterovaginal or Vesicovaginal Fistula Control Using a Silicone Cup.

    Science.gov (United States)

    Russell, Katie W; Robinson, Ryan E; Mone, Mary C; Scaife, Courtney L

    2016-12-01

    An enterovaginal or vesicovaginal fistula is a complication resulting in vaginal discharge of succus, urine, or stool that can lead to significant complications. For low-volume fistulae, tampons or pads may be used. With high-volume fistulae, frequent product change can be painful and unpredictable in terms of efficacy. The psychologic distress is profound. Surgery may not be an option, making symptom control the priority. We report the use of a reusable menstrual silicone vaginal cup placed to divert and contain drainage. The menstrual cup provided significant symptom relief. Drainage is immediately diverted from tissue, unlike with tampon or pad use, which involves longer contact periods with caustic fluids. A system was created by adapting the end of the cup by adding silastic tubing and an external leg bag to provide long-term drainage control. Improvement in quality of life is of primary importance when dealing with fistula drainage. This simple and inexpensive device should be considered in those cases in which the drainage can be diverted as a viable option, especially in those who are symptomatic and awaiting surgical repair or in those for whom surgery cannot be performed.

  8. THE REDUCTION OF CHOLESTEROL WITH CUPPING THERAPY ON CHOLESTEROL REDUCTION IN PATIENTS WITH HYPERCHOLESTEROLEMIA

    Directory of Open Access Journals (Sweden)

    Zahid Fikri

    2017-04-01

    Full Text Available Introduction: Hypercholesterolemia is a risk factor causes of death at younger ages. Hypercholesterolemia may increase the risk of atherosclerosis, coronary heart disease, pancreatitis (pancreas inflammation in organs, diabetes mellitus, thyroid disorders, liver disease and kidney disease. Many patients with hypercholesterolemia using cupping therapy. Cupping therapy is alternative treatment process of throwing dirty blood from the body through the skin surface. The objective of this study was to determine the effect of cupping therapy to decrease cholesterol levels in patients with hypercholesterolemia. Method: Design used in this study was quasy experimental design. The population is all patients with hypercholesterolemia in the health center plaza Gresik. The total sample is 18 respondents, taken according to inclusion criteria. Independent variable is the cupping therapy. The dependent variable was the decrease in cholesterol levels. Data were collected using a questionnaire and observation of cholesterol. Data were analyzed using independent t-test and paired t tests with signi fi cance level α < 0.05. Result: The results show that cholesterol levels in patients with hypercholesterolemia treated groups decreased majority. Independent statistical analysis using t-test showed p = 0.001 and with the Paired t-test p value = 0.003. Discussion: This result means that there are significant effects of cupping therapy on cholesterol reduction in patients with hypercholesterolemia aged 45 years and over. Further research needs to be done in control diet, lifestyle and daily activities for the success of cupping therapy.

  9. Wet cupping therapy for treatment of herpes zoster: a systematic review of randomized controlled trials.

    Science.gov (United States)

    Cao, Huijuan; Zhu, Chenjun; Liu, Jianping

    2010-01-01

    Wet cupping is a traditional Chinese medicine therapy commonly used in treating herpes zoster in China, and clinical studies have shown that wet cupping may have beneficial effect on herpes zoster compared with Western medication. We included randomized controlled trials (RCTs) on wet cupping for herpes zoster. We searched PubMed, the Cochrane Library (Issue 3, 2008), China Network Knowledge Infrastructure (CNKI), Chinese Scientific Journals Fulltext Database VIP, and Wan Fang Database. All searches ended in February 2009. Two authors extracted data and assessed the trials' quality independently. RevMan 5.0.18 software (The Cochrane Collaboration, The Nordic Cochrane Centre, Copenhagen, Denmark) was used for data analysis with effect estimate presented as relative risk (RR) and mean difference (MD) with a 95% confidence interval (CI). Eight RCTs involving 651 patients were included, and the methodological quality of trials was generally fair in terms of randomization, blinding, and intention-to-treat analysis. Meta-analyses showed wet cupping was superior to medication in the number of cured patients (RR 2.49, 95% CI 1.91 to 3.24, P cupping plus medication was significantly better than medication alone on number of cured patients (RR 1.93, 95% CI 1.23 to 3.04, P = .005) but demonstrated no difference in symptom improvement (RR 1.00, 95% CI 0.92 to 1.08, P = .98). There were no serious adverse effects related to wet cupping therapy in the included trials. Wet cupping appears to be effective in the treatment of herpes zoster. However, further large, rigorously designed

  10. Suction removal of sediment from between armour blocks. Part 2. Waves

    DEFF Research Database (Denmark)

    Dixen, Figen Hatipoglu; Sumer, B. Mutlu; Fredsøe, Jørgen

    2008-01-01

    When a stone/armor layer on a sand bed is exposed to flow, the sand underneath will be agitated by the flow turbulence. When the flow velocity reaches a critical value, the sand will be sucked (winnowed out) from between the armor blocks. In a previous investigation, we studied suction removal of...

  11. RoboCup Rescue Robot and Simulation Leagues

    NARCIS (Netherlands)

    Akin, H.L.; Ito, N.; Jacoff, A.; Kleiner, A.; Pellenz, J.; Visser, A.

    2013-01-01

    The RoboCup Rescue Robot and Simulation competitions have been held since 2000. The experience gained during these competitions has increased the maturity level of the field, which allowed deploying robots after real disasters (for example, Fukushima Daiichi nuclear disaster). This article provides

  12. The Study of a Beam Profile Monitor based on Faraday Cup Array

    Energy Technology Data Exchange (ETDEWEB)

    Park, K. M.; Park, S. H.; Kim, S. G.; Kwon, H. J.; Cho, Y. S. [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The metal can then be discharged to measure a small current equivalent to the number of impinging ions. The beam current can be measured and used to determine the number of ions or electrons hitting the cup. Recently, beam profile monitor (BPM) based on Faraday cup array (FCA), which represented beam position through the spatial and temporal distribution of the beam current, has been studied due to advantages of measure of wide-range ion beam current. FCA system is divided into a FC, an electrical circuit and display parts. We have studied FCA to monitor beam profile on an electrostatic accelerator with wide-range ion current. In this paper, we represented basic characteristics and designs for the fabricated FCA. FCA system, which consisted of FC system, electronic readout system, and output display, was suggested to measure ion beam current, efficiently. FC system consisted of a collimator, suppressor, tiny FC, insulator frame, and circuit board divided into elec PCB, cap PCB, and con PCB. FC size was 4 mm diameters and FCA system was considered as 8 x 8 array and whole size of 8 x 8 mm''2. FCA system was set-up in vacuum chamber and an integrator and output display parts were formed out of chamber to minimize number of feed-through.

  13. World Cup, manifestations and the occupation of the public space

    Directory of Open Access Journals (Sweden)

    Luiza Aguiar dos Anjos

    2013-11-01

    Full Text Available Since the announcement of Brazil to host the FIFA World Cup in 2014, social movements organized themselves to denounce and question decisions and arbitrariness about their preparations. During the Confederations Cup of 2013, a series of manifestations marked by the diversity of its participants and their demands became known as the June Journeys. This article presents an analysis of such events focusing on matters relates to the occupation of the public space, problematizing, later, the relation of the movements and the mega sports events in question.

  14. Machine Learning for RealisticBall Detection in RoboCup SPL

    OpenAIRE

    Bloisi, Domenico; Del Duchetto, Francesco; Manoni, Tiziano; Suriani, Vincenzo

    2017-01-01

    In this technical report, we describe the use of a machine learning approach for detecting the realistic black and white ball currently in use in the RoboCup Standard Platform League. Our aim is to provide a ready-to-use software module that can be useful for the RoboCup SPL community. To this end, the approach is integrated within the official B-Human code release 2016. The complete code for the approach presented in this work can be downloaded from the SPQR Team homepage at http://spqr.diag...

  15. World Cup Cities Project: movement by the sport legacy of sporting mega events

    Directory of Open Access Journals (Sweden)

    Rodrigo Pojar Paiva

    2013-11-01

    Full Text Available The achievement of sporting mega events is configured as an exceptional opportunity for the promotion of sports in the host cities. For this positive legacy to happen it must be previously planned, executed and monitored. This study aimed to present the national structure of the World Cup Cities Project and analyse the results obtained in six host cities of the FIFA World Cup 2014. The results showed that the social and sports legacy was not planned by public managers and there are no systems of control and evaluation of sport in any of the host cities, until the realization of the project World Cup Cities.

  16. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    OpenAIRE

    AZZEDINE NAHOUI; LAKHDAR BAHI

    2013-01-01

    A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has de...

  17. Efficacy of cupping therapy in patients with the fibromyalgia syndrome-a randomised placebo controlled trial

    OpenAIRE

    Lauche, Romy; Spitzer, Julia; Schwahn, Barbara; Ostermann, Thomas; Bernardy, Kathrin; Cramer, Holger; Dobos, Gustav; Langhorst, Jost

    2016-01-01

    This study aimed to test the efficacy of cupping therapy to improve symptoms and quality of life in patients diagnosed with the fibromyalgia syndrome. Participants were randomly assigned to cupping therapy, sham or usual care. Cupping was administered five times at twice weekly intervals on the upper and lower back. The primary outcome measure was pain intensity at day 18. Secondary outcomes included functional disability, quality of life, fatigue and sleep quality as well as pressure pain se...

  18. A Constitutive Model for Unsaturated soils based on a Compressibility Framework dependent on Suction and Degree of Saturation

    OpenAIRE

    Sitarenios Panagiotis; Kavvadas Michael

    2016-01-01

    The Modified Cam Clay model is extended to account for the behaviour of unsaturated soils using Bishop’s stress. To describe the Loading – Collapse behaviour, the model incorporates a compressibility framework with suction and degree of saturation dependent compression lines. For simplicity, the present paper describes the model in the triaxial stress space with characteristic simulations of constant suction compression and triaxial tests, as well as wetting tests. The model reproduces an evo...

  19. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study.

    Science.gov (United States)

    Schwarz, Timo Julian; Weber, Markus; Dornia, Christian; Worlicek, Michael; Renkawitz, Tobias; Grifka, Joachim; Craiovan, Benjamin

    2017-09-01

    Purpose  Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method  In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between + 15° anterior and -15° posterior and 0° to 20° rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results  The cup anteversion measured on CT was 23.3°; on AP pelvic radiographs, however, variations in pelvic tilt (± 15°) resulted in anteversion angles between 11.0° and 36.2° (mean error 8.3°± 3.9°). The cup inclination was 34.1° on CT and ranged between 31.0° and 38.7° (m. e. 2.3°± 1.5°) on radiographs. Pelvic rotation between 0° and 20° showed high variation in radiographic anteversion (21.2°-31.2°, m. e. 6.0°± 3.1°) and inclination (34.1°-27.2°, m. e. 3.4°± 2.5°). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6°± 0.2° and in inclination measurements to 0.7° (SD± 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4°± 0.4° for anteversion and to 1.3°± 0.8 for inclination. Conclusion  Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools. Key Points   · Pelvic tilt and rotation influence cup

  20. Investigation on creep behavior of geo-materials with suction control technique

    Directory of Open Access Journals (Sweden)

    Nishimura Tomoyoshi

    2016-01-01

    Full Text Available The compacted bentonite which has typical couple problem associated to thermal - hydration - mechanical – chemical (THMC consist of one component of engineered barrier. Recently, the couple THMC formulation modelling suggested by some researchers can be predicted basically phenomena for engineered barrier that approach to correct evaluate satisfied facilities. The compacted bentonite is essentially unsaturated condition, some behaviors for bentonite has similar or close with generally expansive unsaturated soils. Therefore, hydrations have given significant influence on deformation of compacted bentonite such as swelling. There are many researches for swelling behavior of compacted bentonite within soaking. Extended theoretical or experimental investigations for unsaturated soil mechanics are possible to describe the strength-deformation behavior of compacted bentonite with suction controlling principle. A new method of determining the failure phase such as great axis deformation and destructions like strip of surface in the laboratory is described and the creep behavior of compacted bentonite is considered under maintain of high relative humidity environment. The creep deformation measured using improved cyclic relative humidity control apparatus in terms of specific suction control technique.

  1. Evaluation of Wet Cupping Therapy: Systematic Review of Randomized Clinical Trials.

    Science.gov (United States)

    Al Bedah, Abdullah M N; Khalil, Mohamed K M; Posadzki, Paul; Sohaibani, Imen; Aboushanab, Tamer Shaaban; AlQaed, Meshari; Ali, Gazzaffi I M

    2016-10-01

    Wet cupping is a widely used traditional therapy in many countries, which justifies a continuous scientific evaluation of its efficacy and safety. To perform a systematic review to critically evaluate and update the available evidence of wet cupping in traditional and complementary medicine. Ten electronic databases were searched from their inceptions to February 2016. Included studies were randomized clinical trials (RCTs) that evaluated wet cupping against any type of control interventions in patients with any clinical condition, as well as healthy individuals. Cochrane risk of bias tool was used to appraise the included RCTs. Fourteen RCTs met the eligibility criteria. The included studies evaluated the following clinical conditions: nonspecific low back pain (NSLBP), hypertension, brachialgia, carpal tunnel syndrome (CTS), chronic neck pain, metabolic syndrome, migraine headaches, oxygen saturation in smokers with chronic obstructive pulmonary disease (COPD), and oral and genital ulcers due to Behçet disease. Two RCTs evaluated physiologic and biochemical parameters of healthy individuals. Overall, 9 RCTs favored wet cupping over various control interventions in NSLBP (n = 2), hypertension (n = 1), brachialgia (n = 1), CTS (n = 1), chronic neck pain (n = 2), oxygen saturation in smokers with COPD (n = 1), and oral and genital ulcers due to Behçet disease (n = 1). Five RCTs showed no statistically significant between-group differences: NSLBP (n = 1), metabolic syndrome (n = 1), migraine headaches (n = 1), and physiologic and biochemical parameters of healthy individuals (n = 2). Included RCTs had a variable risk of bias across all domains and suffered methodologic limitations. There is a promising evidence in favor of the use of wet cupping for musculoskeletal pain, specifically NSLBP, neck pain, CTS, and brachialgia. Better-quality trials are needed to generate solid evidence and firmly inform policy makers.

  2. Joint optic disc and cup boundary extraction from monocular fundus images.

    Science.gov (United States)

    Chakravarty, Arunava; Sivaswamy, Jayanthi

    2017-08-01

    Accurate segmentation of optic disc and cup from monocular color fundus images plays a significant role in the screening and diagnosis of glaucoma. Though optic cup is characterized by the drop in depth from the disc boundary, most existing methods segment the two structures separately and rely only on color and vessel kink based cues due to the lack of explicit depth information in color fundus images. We propose a novel boundary-based Conditional Random Field formulation that extracts both the optic disc and cup boundaries in a single optimization step. In addition to the color gradients, the proposed method explicitly models the depth which is estimated from the fundus image itself using a coupled, sparse dictionary trained on a set of image-depth map (derived from Optical Coherence Tomography) pairs. The estimated depth achieved a correlation coefficient of 0.80 with respect to the ground truth. The proposed segmentation method outperformed several state-of-the-art methods on five public datasets. The average dice coefficient was in the range of 0.87-0.97 for disc segmentation across three datasets and 0.83 for cup segmentation on the DRISHTI-GS1 test set. The method achieved a good glaucoma classification performance with an average AUC of 0.85 for five fold cross-validation on RIM-ONE v2. We propose a method to jointly segment the optic disc and cup boundaries by modeling the drop in depth between the two structures. Since our method requires a single fundus image per eye during testing it can be employed in the large-scale screening of glaucoma where expensive 3D imaging is unavailable. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Significant and sustaining elevation of blood oxygen induced by Chinese cupping therapy as assessed by near-infrared spectroscopy.

    Science.gov (United States)

    Li, Ting; Li, Yaoxian; Lin, Yu; Li, Kai

    2017-01-01

    Cupping therapy has been used in traditional Chinese medicine for thousands of years to relieve muscle pain/tendency/fatigue and to cure or reduce symbols of other diseases. However, its therapeutic effect is sparsely interpreted in the language of modern physiology. To objectively evaluate its therapeutic effect, we focused on dry cupping treatment and utilized near-infrared spectroscopy (NIRS) to assess the concentration change in oxy-hemoglobin ([HbO 2 ]), deoxy-hemoglobin ([Hb]), and blood volume in the course of cupping therapy over 13 volunteers on the infraspinatus muscle, where is usually applied for shoulder pains. Both a prominent drop in [Hb] and a significant elevation in [HbO 2 ] in the tissue surrounding the cupping site were observed during both cupping and post-treatment, manifesting the enhancement of oxygen uptake. This resulting promotion indicates potential positive therapeutic effect of cupping therapy in hemodynamics for facilitating muscular functions.

  4. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    Science.gov (United States)

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  5. Inverse analyses of effective diffusion parameters relevant for a two-phase moisture model of cementitious materials

    DEFF Research Database (Denmark)

    Addassi, Mouadh; Johannesson, Björn; Wadsö, Lars

    2018-01-01

    Here we present an inverse analyses approach to determining the two-phase moisture transport properties relevant to concrete durability modeling. The purposed moisture transport model was based on a continuum approach with two truly separate equations for the liquid and gas phase being connected...... test, and, (iv) capillary suction test. Mass change over time, as obtained from the drying test, the two different cup test intervals and the capillary suction test, was used to obtain the effective diffusion parameters using the proposed inverse analyses approach. The moisture properties obtained...

  6. Comparison of numerical formulations for the modeling of tensile loaded suction buckets

    DEFF Research Database (Denmark)

    Sørensen, Emil Smed; Clausen, Johan Christian; Damkilde, Lars

    2017-01-01

    The tensile resistance of a suction bucket is investigated using three different numerical formulations. The first formulation utilizes the three-field u-p-U formulation accounting for solid and fluid displacements, u and U, as well as the pore-fluid pressure, p. The two other formulations compri...

  7. Long term effects of cyclic loading on suction caisson foundations in sand

    NARCIS (Netherlands)

    Lupea, C.; Thijssen, R.; Van Tol, A.F.

    2014-01-01

    Offshore wind turbine projects have been characterised by an increase in costs, sizes and distances from shore, EWEA 2012 This created a need of investigating the adequacy of alternative and more fìnancially attractive foundation types such as suction caissons. Within a multi-footing configuration,

  8. Impact of currently marketed tampons and menstrual cups on Staphylococcus aureus growth and TSST-1 production in vitro.

    Science.gov (United States)

    Nonfoux, Louis; Chiaruzzi, Myriam; Badiou, Cédric; Baude, Jessica; Tristan, Anne; Thioulouse, Jean; Muller, Daniel; Prigent Combaret, Claire; Lina, Gérard

    2018-04-20

    Fifteen currently marketed intravaginal protection products (11 types of tampon and four menstrual cups) were tested by the modified tampon sac method to determine their effect on Staphylococcus aureus growth and toxic shock toxin 1 (TSST-1) production. Most tampons reduced S. aureus growth and TSST-1 production, with differences based on brand and composition, and S. aureus growth was higher in de-structured than in unaltered tampons. We observed higher S. aureus growth and toxin production in menstrual cups than in tampons, potentially due to the additional air introduced to the bag by cups, with differences based on cup composition and size. Importance Menstrual toxic shock syndrome is a rare but severe disease. It occurs in healthy women vaginally colonized by Staphylococcus aureus producing toxic shock syndrome toxin 1 using intravaginal protection such as tampons or menstrual cups. Intravaginal protection induces TSS production by collecting catamenial products which act as a growth medium for S. aureus Previous studies have evaluated the impact of tampon composition on S. aureus producing toxic shock syndrome toxin 1, but they are not recent and did not include menstrual cups. This study demonstrates that highly reproducible results for S. aureus growth and TSST-1 production can be obtained using a simple protocol that reproduces the physiological conditions of tampon and cup usage as closely as possible, providing recommendations for tampon or cup use to both manufacturers and consumers. Notably, our results do not show that menstrual cups are safer than tampons and suggest that they require similar precautions. Copyright © 2018 American Society for Microbiology.

  9. A variable suppressed aperture and Faraday cup system

    International Nuclear Information System (INIS)

    Price, H.G.; Charlesworth, T.R.

    1979-02-01

    The injection system of the NSF accelerator within the high voltage enclosure is illustrated. The optics calls for a waist close to the entrance of the 500 kV accelerator tube. This waist will be the initial diagnostic point on the injection path for determining ion source performance and transmission through the later system. This will be made by determining the beam current after a preliminary mass analysis by the 30 0 magnet. To provide this diagnostic and to enable a waist to be formed at this point, a variable aperture and Faraday cup system is required. The Faraday cup will measure the beam transmitted by the aperture. Maximisation of this beam by adjustment of the preceding optical elements will ensure the waist in the beam at that point. (author)

  10. Radiological diagnostics in CUP syndrome; Radiologische Diagnostik des CUP-Syndroms

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, P.M.; Nikolaou, K.; Graser, A.; Reiser, M.F.; Cyran, C.C. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Rominger, A. [Klinikum der Ludwig-Maximilians-Universitaet, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2014-02-15

    Imaging plays an essential role in the therapeutic management of cancer of unknown primary (CUP) patients for localizing the primary tumor, for the identification of tumor entities for which a dedicated therapy regimen is available and for the characterization of clinicopathological subentities that direct the subsequent diagnostic and therapeutic strategy. Modalities include conventional x-ray, computed tomography (CT), magnetic resonance imaging (MRI) and ultrasound as well as positron emission tomography (PET)-CT and MRI-PET. In whole body imaging CT has a high sensitivity for tumor entities which frequently present as a metastasized cancer illness. According to the current literature CT is diagnostic in 86% of patients with pancreatic carcinoma, in 36% of patients with colon carcinoma and in 74% of patients with lung carcinoma. Additionally a meta-analysis showed that for patients with squamous cell carcinoma and cervical lymph node metastases a positive diagnosis was possible in 22% of the cases using CT, in 36% using MRI and in 28-57% using 18F-fluorodeoxyglucose PET-CT ({sup 18}F-FDG PET-CT). In addition, MRI plays an important role in the localization of primary occult tumors (e.g. breast and prostate) because of its high soft tissue contrast and options for functional imaging. At the beginning of the diagnostic algorithm stands the search for a possible primary tumor and CT of the neck, thorax and abdomen is most frequently used for whole body staging. Subsequent organ-specific imaging examinations follow, e.g. mammography in women with axillary lymphadenopathy. For histological and immunohistochemical characterization of tumor tissue, imaging is also applied to identify the most accessible and representative tumor manifestation for biopsy. Tumor biopsy may be guided by CT, MRI or ultrasound and MRI also plays a central role in the localization of primary occult tumors because of superior soft tissue contrast and options for functional imaging (perfusion

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far ... Use Facts About Colored Contacts and Halloween Safety Colored ...

  12. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

    Science.gov (United States)

    Derbyshire, Brian

    2018-03-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient's pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective.

  13. Design and Implementation of a General Decision-Making Model in RoboCup Simulation

    Directory of Open Access Journals (Sweden)

    Changda Wang

    2004-09-01

    Full Text Available The study of the collaboration, coordination and negotiation among different agents in a multi-agent system (MAS has always been the most challenging yet popular in the research of distributed artificial intelligence. In this paper, we will suggest for RoboCup simulation, a typical MAS, a general decision-making model, rather than define a different algorithm for each tactic (e.g. ball handling, pass, shoot and interception, etc. in soccer games as most RoboCup simulation teams did. The general decision-making model is based on two critical factors in soccer games: the vertical distance to the goal line and the visual angle for the goalpost. We have used these two parameters to formalize the defensive and offensive decisions in RoboCup simulation and the results mentioned above had been applied in NOVAURO®, original name is UJDB, a RoboCup simulation team of Jiangsu University, whose decision-making model, compared with that of Tsinghua University, the world champion team in 2001, is a universal model and easier to be implemented.

  14. The challenge of pelvic discontinuity: cup-cage reconstruction does better than conventional cages in mid-term.

    Science.gov (United States)

    Abolghasemian, M; Tangsaraporn, S; Drexler, M; Barbuto, R; Backstein, D; Safir, O; Kuzyk, P; Gross, A

    2014-02-01

    The use of ilioischial cage reconstruction for pelvic discontinuity has been replaced by the Trabecular Metal (Zimmer, Warsaw, Indiana) cup-cage technique in our institution, due to the unsatisfactory outcome of using a cage alone in this situation. We report the outcome of 26 pelvic discontinuities in 24 patients (20 women and four men, mean age 65 years (44 to 84)) treated by the cup-cage technique at a mean follow-up of 82 months (12 to 113) and compared them with a series of 19 pelvic discontinuities in 19 patients (18 women and one man, mean age 70 years (42 to 86)) treated with a cage at a mean follow-up of 69 months (1 to 170). The clinical and radiological outcomes as well as the survivorship of the groups were compared. In all, four of the cup-cage group (15%) and 13 (68%) of the cage group failed due to septic or aseptic loosening. The seven-year survivorship was 87.2% (95% confidence interval (CI) 71 to 103) for the cup-cage group and 49.9% (95% CI 15 to 84) for the cage-alone group (p = 0.009). There were four major complications in the cup-cage group and nine in the cage group. Radiological union of the discontinuity was found in all successful cases in the cup-cage group and three of the successful cage cases. Three hips in the cup-cage group developed early radiological migration of the components, which stabilised with a successful outcome. Cup-cage reconstruction is a reliable technique for treating pelvic discontinuity in mid-term follow-up and is preferred to ilioischial cage reconstruction. If the continuity of the bone graft at the discontinuity site is not disrupted, early migration of the components does not necessarily result in failure.

  15. Model-Based Design of Brushless DC Motor Control and Motion Control Modelling for RoboCup SSL Robots

    OpenAIRE

    Li, Xiaotian

    2015-01-01

    Over the recent years, the RoboCup competition has grown popular and attracted more and more domestic and international universities, and the levels of the teams increase every year. In Small Size League (SSL) competition, besides a good strategy system, the precision of the robots’ actions is also of vital importance in order to achieve high performance. Thus, a highly accurate and stable motion control system is needed to drive the robots to move in accordance with the planned trajectory. C...

  16. Successful Laparoscopically Assisted Transcervical Suction Evacuation of Interstitial Pregnancy following Failed Methotrexate Injection in a Community Hospital Setting

    Directory of Open Access Journals (Sweden)

    Rani B. Fritz

    2014-01-01

    Full Text Available We report on a case of a patient with an early diagnosed cornual ectopic pregnancy following failed methotrexate treatment. The patient was subsequently taken to the operating room for a laparoscopic guided transcervical suction curettage of the cornual ectopic. The surgery was successful and the patient was followed up until her urine pregnancy test was negative. We conclude that in properly selected patients, cornual ectopic pregnancy may be treated with transcervical suction curettage.

  17. Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Liu

    2015-01-01

    Full Text Available This study was conducted to evaluate the effects of open endotracheal suctioning on gas exchange and respiratory mechanics in ARF patients under the modes of PCV or VCV. Ninety-six ARF patients were treated with open endotracheal suctioning and their variations in respiratory mechanics and gas exchange after the suctions were compared. Under PCV mode, compared with the initial level of tidal volume (VT, ARF patients showed 30.0% and 27.8% decrease at 1 min and 10 min, respectively. Furthermore, the initial respiratory system compliance (Crs decreased by 29.6% and 28.5% at 1 min and 10 min, respectively. Under VCV mode, compared with the initial level, 38.6% and 37.5% increase in peak airway pressure (PAP were found at 1 min and 10 min, respectively. Under PCV mode, the initial PaO2 increased by 6.4% and 10.2 % at 3 min and 10 min, respectively, while 18.9% and 30.6% increase of the initial PaO2 were observed under VCV mode. Summarily, endotracheal suctioning may impair gas exchange and decrease lung compliance in ARF patients receiving mechanical ventilation under both PCV and VCV modes, but endotracheal suctioning effects on gas exchange were more severe and longer-lasting under PCV mode than VCV.

  18. Aerosol distribution during open suctioning and long-term surveillance of air quality in a respiratory care center within a medical center.

    Science.gov (United States)

    Chung, Fen-Fang; Lin, Hui-Ling; Liu, Hsueh-Erh; Lien, Angela Shin-Yu; Hsiao, Hsiu-Feng; Chou, Lan-Ti; Wan, Gwo-Hwa

    2015-01-01

    The investigation of hospital air quality has been conducted in wards, ICUs, operating theaters, and public areas. Few studies have assessed air quality in respiratory care centers (RCCs), especially in mechanically ventilated patients with open suctioning. The RCC air quality indices (temperature, relative humidity, levels of CO2, total volatile organic compounds, particulate matter [PM], bacteria, and fungi) were monitored over 1 y. The air around the patient's head was sampled during open suctioning to examine the probability of bioaerosol exposure affecting health-care workers. This investigation found that the levels of indoor air pollutants (CO2, PM, bacteria, and fungi) were below the indoor air quality standard set by the Taiwan Environmental Protection Agency. Meanwhile, the levels of total volatile organic compounds sometimes exceeded the indoor air quality standard, particularly in August. The identified bacterial genera included Micrococcus species, Corynebacterium species, and Staphylococcus species, and the predominant fungal genera included yeast, Aspergillus species, Scopulariopsis species, and Trichoderma species. Additionally, airborne PM2.5, PM1, and bacteria were clearly raised during open suctioning in mechanically ventilated patients. This phenomenon demonstrated that open suctioning may increase the bacterial exposure risk of health-care workers. RCC air quality deserves long-term monitoring and evaluation. Health-care workers must implement self-protection strategies during open suctioning to ensure their occupational health and safety in health-care settings. Copyright © 2015 by Daedalus Enterprises.

  19. Efficacy of a Pelvic Lateral Positioner With a Mechanical Cup Navigator Based on the Anatomical Pelvic Plane in Total Hip Arthroplasty.

    Science.gov (United States)

    Iwakiri, Kentaro; Kobayashi, Akio; Ohta, Yoichi; Minoda, Yukihide; Takaoka, Kunio; Nakamura, Hiroaki

    2017-12-01

    The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide. The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators. The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Development in corrosion resistance by microstructural refinement in Zr-16 SS 304 alloy using suction casting technique

    Energy Technology Data Exchange (ETDEWEB)

    Das, N., E-mail: nirupamd@barc.gov.in; Sengupta, P.; Abraham, G.; Arya, A.; Kain, V.; Dey, G.K.

    2016-08-15

    Highlights: • Grain refinement was made in Zr–16 wt.% SS alloy while prepared by suction casting process. • Distribution of Laves phase, e.g., Zr{sub 2}(Fe, Cr) was raised in suction cast (SC) Zr–16 wt.% SS. • Corrosion resistance was improved in SC alloy compared to that of arc-melt-cast alloy. • Grain refinement in SC alloy assisted for an increase in its corrosion resistance. - Abstract: Zirconium (Zr)-stainless steel (SS) hybrid alloys are being considered as baseline alloys for developing metallic-waste-form (MWF) with the motivation of disposing of Zr and SS base nuclear metallic wastes. Zr–16 wt.% SS, a MWF alloy optimized from previous studies, exhibit significant grain refinement and changes in phase assemblages (soft phase: Zr{sub 2}(Fe, Cr)/α-Zr vs. hard phase: Zr{sub 3}(Fe, Ni)) when prepared by suction casting (SC) technique in comparison to arc-cast-melt (AMC) route. Variation in Cr-distribution among different phases are found to be low in suction cast alloy, which along with grain refinement restricted Cr-depletion at the Zr{sub 2}(Fe, Cr)/Zr interfaces, prone to localized attack. Hence, SC alloy, compared to AMC alloy, showed lower current density, higher potential at the breakdown of passivity and higher corrosion potential during polarization experiments (carried out under possible geological repository environments, viz., pH 8, 5 and 1) indicating its superior corrosion resistance.