WorldWideScience

Sample records for small specimen test

  1. Some recent innovations in small specimen testing

    International Nuclear Information System (INIS)

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  2. Damage modeling in Small Punch Test specimens

    DEFF Research Database (Denmark)

    Martínez Pañeda, Emilio; Cuesta, I.I.; Peñuelas, I.

    2016-01-01

    . Furthermore,Gurson-Tvergaard-Needleman model predictions from a top-down approach are employed to gain insightinto the mechanisms governing crack initiation and subsequent propagation in small punch experiments.An accurate assessment of micromechanical toughness parameters from the SPT...

  3. Fracture toughness evaluation of Eurofer'97 by testing small specimens

    International Nuclear Information System (INIS)

    Serrano, M.; Fernandez, P.; Lapena, J.

    2006-01-01

    The Eurofer'97 is the structural reference material that will be tested in the ITER modules. Its metallurgical properties have been well characterized during the last years. However, more investigations related with the fracture toughness of this material are necessary because this property is one of the most important to design structural components and to study their integrity assessment. In the case of structural materials for fusion reactor the small specimen technology (SSTT) are being actively developed to investigate the fracture toughness among other mechanical properties. The use of small specimens is due to the small available irradiation volume of IFMIF and also due to the high fluence expected in the fusion reactor. The aim of this paper is to determine the fracture toughness of the Eurofer'97 steel by testing small specimens of different geometry in the ductile to brittle transition region, with the application of the Master Curve methodology, and to evaluate this method to assess the decrease in fracture toughness due to neutron irradiation. The tests and data analysis have been performed following the Master Curve approach included in the ASTM Standard E1921-05. Specimen size effect and comparison of the fracture toughness results with data available in the literature are also considered. (author)

  4. Development of small specimen test techniques. Development of a remote controlled small punch testing apparatus

    International Nuclear Information System (INIS)

    Ohmi, Masao; Saito, Junichi; Ooka, Norikazu; Jitsukawa, Shiro; Hishinuma, Akimichi; Umino, Akira.

    1997-01-01

    An accelerator-driven deuterium-lithium (d-Li) stripping reaction-type neutron source, such as the International Fusion Materials Irradiation Facility (IFMIF) planned by the International Energy Agency is recognized as one of the most promising facility to obtain test environments of high-energy neutrons for fusion reactor materials development. The limitation on the available irradiation volume of the irradiation facility requires the development of the small specimen test techniques (SSTT). Application of SSTT to evaluate the degradation of various components in the light water reactor for the life extension is expected to be also quite beneficial. A remote-controlled testing machine for the Small Punch (SP) and miniaturized tensile tests was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR). The machine is designed for testing at temperatures ranging between 93 and 1,123 K to evaluate the temperature dependence of the strength of materials including the embrittlement at low temperatures and the softening at elevated temperatures. The tests are performed in a vacuum or in an inert gas environment. The machine has been installed in a hot cell and is being used for the round robin test program of the SP test method. The round robin test program is planned to identify the capability of the test method and to establish a standard test procedure. The configuration and the specifications of the test machine are introduced and the results of the SP tests are also shown. (author)

  5. Small Scale Yielding Correction of Constraint Loss in Small Sized Fracture Toughness Test Specimens

    International Nuclear Information System (INIS)

    Kim, Maan Won; Kim, Min Chul; Lee, Bong Sang; Hong, Jun Hwa

    2005-01-01

    Fracture toughness data in the ductile-brittle transition region of ferritic steels show scatter produced by local sampling effects and specimen geometry dependence which results from relaxation in crack tip constraint. The ASTM E1921 provides a standard test method to define the median toughness temperature curve, so called Master Curve, for the material corresponding to a 1T crack front length and also defines a reference temperature, T 0 , at which median toughness value is 100 MPam for a 1T size specimen. The ASTM E1921 procedures assume that high constraint, small scaling yielding (SSY) conditions prevail at fracture along the crack front. Violation of the SSY assumption occurs most often during tests of smaller specimens. Constraint loss in such cases leads to higher toughness values and thus lower T 0 values. When applied to a structure with low constraint geometry, the standard fracture toughness estimates may lead to strongly over-conservative estimates. A lot of efforts have been made to adjust the constraint effect. In this work, we applied a small-scale yielding correction (SSYC) to adjust the constraint loss of 1/3PCVN and PCVN specimens which are relatively smaller than 1T size specimen at the fracture toughness Master Curve test

  6. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  7. Development of piezoelectric ceramics driven fatigue testing machine for small specimens

    International Nuclear Information System (INIS)

    Saito, S.; Kikuchi, K.; Onishi, Y.; Nishino, T.

    2002-01-01

    A new fatigue testing machine with piezoelectric ceramics actuators was developed and a prototype was manufactured for high-cycle fatigue tests with small specimens. The machine has a simple mechanism and is compact. These features make it easy to set up and to maintain the machine in a hot cell. The excitation of the actuator can be transmitted to the specimen using a lever-type testing jig. More than 100 μm of displacement could be prescribed precisely to the specimen at a frequency of 50 Hz. This was sufficient performance for high-cycle bend fatigue tests on specimens irradiated at the SINQ target in Paul Scherrer Institute. The relationship of a displacement applied to the specimen and the strain of the necking part were obtained by experimental methods and by finite element method (FEM) calculations. Both results showed good agreement. This fact makes it possible to evaluate the strain of irradiated specimens by FEM simulations

  8. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  9. Relationships between Loblolly Pine small clear specimens and Dimension Lumber Tested in Static Bending

    Science.gov (United States)

    Mark Alexander Butler; Joseph Dahlen; Finto Antony; Michael Kane; Thomas L. Eberhardt; Huizhe Jin; Kim Love-Myers; John Paul McTague

    2016-01-01

    Prior to the 1980s, the allowable stresses for lumber in North America were derived from testing of small clear specimens. However, the procedures were changed because these models were found to be inaccurate. Nevertheless, small clear testing continues to be used around the world for allowable stress determinations and in studies that examine forest management impacts...

  10. Test methodology and technology of fracture toughness for small size specimens

    Energy Technology Data Exchange (ETDEWEB)

    Wakai, E.; Takada, F.; Ishii, T.; Ando, M. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Matsukawa, S. [JNE Techno-Research Co., Kanagawa-ken (Japan)

    2007-07-01

    Full text of publication follows: Small specimen test technology (SSTT) is required to investigate mechanical properties in the limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources. The test methodology guideline and the manufacture processes for very small size specimens have not been established, and we would have to formulate it. The technology to control exactly the load and displacement is also required in the test technology under the environment of high dose radiation produced from the specimens. The objective of this study is to examine the test technology and methodology of fracture toughness for very small size specimens. A new bend test machine installed in hot cell has been manufactured to obtain fracture toughness and DBTT (ductile - brittle transition temperature) of reduced-activation ferritic/martensitic steels for small bend specimens of t/2-1/3PCCVN (pre-cracked 1/3 size Charpy V-notch) with 20 mm length and DFMB (deformation and fracture mini bend specimen) with 9 mm length. The new machine can be performed at temperatures from -196 deg. C to 400 deg. C under unloading compliance method. Neutron irradiation was also performed at about 250 deg. C to about 2 dpa in JMTR. After the irradiation, fracture toughness and DBTT were examined by using the machine. Checking of displacement measurement between linear gauge of cross head's displacement and DVRT of the specimen displacement was performed exactly. Conditions of pre-crack due to fatigue in the specimen preparation were also examined and it depended on the shape and size of the specimens. Fracture toughness and DBTT of F82H steel for t/2-1/3PCCVN, DFMB and 0.18DCT specimens before irradiation were examined as a function of temperature. DBTT of smaller size specimens of DFMB was lower than that of larger size specimen of t/2-1/3PCCVN and 0.18DCT. The changes of fracture toughness and DBTT due to irradiation were also

  11. ASTM international symposium on small specimen test techniques and their applications to pressure vessel annealing and plant life extension

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Heinisch, H.L.; Kumar, A.S.

    1992-01-01

    Miniature sheet-type tensile specimens are currently being used in a variety of radiation damage studies conducted in a number of different reactors. Although these specimens are very small, they have proven successful in addressing issues encountered in both thermal reactors and anticipated fusion reactors. This paper reviews the results of a number of recent studies that illustrate the range of applicability of these small specimens. When combined with other types of specimens and other types of measurements made prior to tensile testing, miniature tensile specimens have been found to serve as very useful tools for application to both fundamental studies and alloy screening studies

  12. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    Energy Technology Data Exchange (ETDEWEB)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-10-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength.

  13. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    International Nuclear Information System (INIS)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-01-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength

  14. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  15. Progress in Tissue Specimens Alternative for the Driver Genes Testing of Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yan SUN

    2015-06-01

    Full Text Available Target treatment based on driver genes in advanced non-small cell lung cancer is very important currently. Tumor tissues is the gold standard for driver genes testing. However, most of patients could not get the gene information for lack of enough tissues. To explore the tissue specimens alternatives is a hot spot in clinical work. This report reviews the tissue specimen alternatives of driver gene testing in non-small cell lung cancer.

  16. Conversion of fracture toughness testing values from small scale three point bending test specimens to small scale yielding state (SSY) by elastic-plastic stress analysis

    International Nuclear Information System (INIS)

    Ikonen, K.

    1993-07-01

    The report describes the work performed for achieving readiness to calculate fracture toughness dependence on dimension effects and loading conditions in fracture test specimens and real structures. In the report two- and three-dimensional computer codes developed and calculational methods applied are described. One of the main goals is to converse fracture toughness from small scale three point bending test specimens to case of a depth crack in plane strain i.e. to small scale yielding state (SSY) by numerical elastic-plastic stress analysis. Thickness effect of a test specimens and effect of a crack depth are separately investigated. Tests of three point bending specimens with and without sidegrooves and curved crack front are numerically simulated and experimental and computed results are compared. J-integral is calculated along crack front and also from force-deflection dependence of the beam. For the analyses the computing system was thoroughly automatized. Measuring capacity of three point bending test specimens was tried to evaluate. (orig.) (7 refs., 54 figs.)

  17. Small specimen test technology of fracture toughness in structural material F82H steel for fusion nuclear reactors

    International Nuclear Information System (INIS)

    Wakai, Eiichi; Ohtsuka, Hideo; Jitsukawa, Shiro; Matsukawa, Shingo; Ando, Masami

    2006-03-01

    Small specimen test technology (SSTT) has been developed to investigate mechanical properties of nuclear materials. SSTT has been driven by limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources, and it is very useful for the reduction of waste materials produced in nuclear engineering. In this study new bend test machines have been developed to obtain fracture behaviors of F82H steel for very small bend specimens of pre-cracked t/2-1/3CVN (Charpy V-notch) with 20 mm-length and DFMB (deformation and fracture mini bend specimen) with 9 mm-length and disk compact tension of 0.18DCT type, and fracture behaviors were examined to evaluate DBTT (ductile-brittle transition temperature) at temperature from -180 to 25degC. The effect of specimen size on DBTT of F82H steel was also examined by using Charpy type specimens such as 1/2t-CVN, 1/3CVN and t/2-1/3CVN. In this paper, it also provides the information of the specimens irradiated at 250degC and 350degC to about 2 dpa in the capsule of 04M-67A and 04M-68A of JMTR experiments. (author)

  18. Predicting crack instability behavior of burst tests from small specimens for irradiated Zr-2.5Nb pressure tubes

    International Nuclear Information System (INIS)

    Davies, P.H.

    1997-01-01

    A scaling approach, based on the deformation J-integral at maximum load obtained from small specimens, is proposed for predicting the crack instability behavior of burst tests on irradiated Zr-2.5Nb pressure tubes. An assessment of this approach is carried out by comparison with other toughness criteria such as the modified J-integral and the plastic work dissipation rate approach. The largest discrepancy between the different parameters occurs for materials of intermediate toughness which exhibit the most stable crack growth and tunnelling up to maximum load. A study of one material of intermediate toughness suggests crack-front tunnelling has a significant influence on the results obtained from the 17-mm-wide specimens. It is shown that for a tube of intermediate toughness the different approaches can significantly underpredict the extent of stable crack growth before instability in a burst test even after correcting for tunnelling. The usefulness of a scaling approach in reducing the discrepancy between the small- and large-scale specimen results for this material is demonstrated

  19. Splitting tests on rock specimens

    Energy Technology Data Exchange (ETDEWEB)

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  20. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    International Nuclear Information System (INIS)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T.

    1998-01-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  1. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T. [Valtion Teknillinen Tutkimuskeskus, Espoo (Finland)

    1998-11-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  2. Development of fatigue life evaluation method using small specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  3. Specimen size effects in Charpy impact testing

    International Nuclear Information System (INIS)

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  4. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    Science.gov (United States)

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].

  5. Conclusions regarding fracture mechanics testing and evaluation of small specimens - As evidenced by the finnish contribution to the IAEA CRP3 programme

    Energy Technology Data Exchange (ETDEWEB)

    Wallin, K; Valo, M; Rintamaa, R; Torronen, K [Technical Research Centre of Finland, Espoo (Finland); Ahlstrand, R [Imatran Voima Oy (IVO), Helsinki (Finland)

    1994-12-31

    An extensive mechanical property evaluation has been carried out on various specimens (a Japanese steel plate (JRQ), a French forging material (FFA) and a Japanese forging material (JFL)) in the as-received and irradiated conditions. The mechanical properties measured at different temperatures include Charpy-V notch and instrumented pre-cracked Charpy data and static and dynamic elastic-plastic fracture toughness based on the J-integral, with various specimen size and geometry. Test analysis lead to conclusions regarding the use of small specimen fracture mechanical tests for investigating irradiation effects: CVN{sub pc} and RCT type specimens are suitable for determining the materials fracture toughness even in the ductile/brittle transition region provided the elastic-plastic parameter K{sub JC} is applied together with a statistical size correction. These two specimen types yield equivalent results for the fracture toughness transition shift. Charpy-V appears not to be suitable for estimating the static fracture toughness transition shift. 8 refs., 11 figs.

  6. Validity of fracture toughness determined with small bend specimens

    International Nuclear Information System (INIS)

    Wallin, K.; Rintamaa, R.; Valo, M.

    1994-02-01

    This report considers the validity of fracture toughness estimates obtained with small bend specimens in relation to fracture toughness estimates obtained with large specimens. The study is based upon the analysis and comparison of actual test results. The results prove the validity of the fracture toughness determined based upon small bend specimens, especially when the results are only used to determine the fracture toughness transition temperature T o . In this case the possible error is typically less than 5 deg C and at most 10 deg C. It can be concluded that small bend specimens are very suitable for the estimation of fracture toughness in the case of brittle fracture, provided the results are corrected for statistical size effects. (orig.). (20 refs., 17 figs.)

  7. Mechanical characteristics of historic mortars from tests on small-sample non-standard on small-sample non-standard specimens

    Czech Academy of Sciences Publication Activity Database

    Drdácký, Miloš; Slížková, Zuzana

    2008-01-01

    Roč. 17, č. 1 (2008), s. 20-29 ISSN 1407-7353 R&D Projects: GA ČR(CZ) GA103/06/1609 Institutional research plan: CEZ:AV0Z20710524 Keywords : small-sample non-standard testing * lime * historic mortar Subject RIV: AL - Art, Architecture, Cultural Heritage

  8. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  9. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  10. The measurement of power losses at high magnetic field densities or at small cross-section of test specimen using the averaging

    CERN Document Server

    Gorican, V; Hamler, A; Nakata, T

    2000-01-01

    It is difficult to achieve sufficient accuracy of power loss measurement at high magnetic field densities where the magnetic field strength gets more and more distorted, or in cases where the influence of noise increases (small specimen cross section). The influence of averaging on the accuracy of power loss measurement was studied on the cast amorphous magnetic material Metglas 2605-TCA. The results show that the accuracy of power loss measurements can be improved by using the averaging of data acquisition points.

  11. Fabrication and testing of prestressed composite rotor blade spar specimens

    Science.gov (United States)

    Gleich, D.

    1974-01-01

    Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.

  12. Small specimen measurements of dynamic fracture toughness of heavy section steels for nuclear pressure vessel

    International Nuclear Information System (INIS)

    Tanaka, Y.; Iwadate, T.; Suzuki, K.

    1987-01-01

    This study presents the dynamic fracture toughness properties (KId) of 12 heats of RPV steels measured using small specimens and analysed based on the current research. The correlation between the KId test and other engineering small specimen tests such as Charpy test and drop weight test are also discussed and a method to predict the KId value is presented. (orig./HP)

  13. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  14. Development of electric discharge equipment for small specimen sampling

    International Nuclear Information System (INIS)

    Okamoto, Koji; Kitagawa, Hideaki; Kusumoto, Junichi; Kanaya, Akihiro; Kobayashi, Toshimi

    2009-01-01

    We have developed the on-site electric discharge sampling equipment that can effectively take samples such as small specimens from the surface portion of the plant components. Compared with the conventional sampling equipment, our sampling equipment can take samples that are thinner in depth and larger in area. In addition, the affection to the equipment can be held down to the minimum, and the thermally-affected zone of the material due to electric discharge is small, which is to be ignored. Therefore, our equipment is excellent in taking samples for various tests such as residual life evaluation.

  15. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    Science.gov (United States)

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  16. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  17. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  18. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  19. Thermal endurance tests on silicone rubber specimens

    International Nuclear Information System (INIS)

    Warburton, C.

    1977-07-01

    Thermal endurance tests have been performed on a range of silicone rubber specimens at temperature above 300 0 C. It is suggested that the rubber mix A2426, the compound from which Wylfa sealing rings are manufactured, will fail at temperatures above 300 0 C within weeks. Hardness measurements show that this particular rubber performs in a similar manner to Walker's S.I.L./60. (author)

  20. Corrosion testing of uranium silicide fuel specimens

    International Nuclear Information System (INIS)

    Bourns, W.T.

    1968-09-01

    U 3 Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300 o C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U 3 5i specimen which corrodes at less than 2 mg/cm 2 h in 300 o C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U 3 Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300 o C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  1. Corrosion testing of uranium silicide fuel specimens

    Energy Technology Data Exchange (ETDEWEB)

    Bourns, W T

    1968-09-15

    U{sub 3}Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300{sup o}C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U{sub 3}5i specimen which corrodes at less than 2 mg/cm{sup 2} h in 300{sup o}C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U{sub 3}Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300{sup o}C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  2. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    International Nuclear Information System (INIS)

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  3. Relationship between strain and central deflection in small punch creep specimens

    International Nuclear Information System (INIS)

    Yang Zhen; Wang Zhiwen

    2003-01-01

    Acquiring information about creep strain directly from small punch creep tests is difficult because the deformation behaviour of the small punch specimen is complicated. A routine is suggested in the present paper to treat this problem indirectly. Based on a finite element analysis, it is proposed that the relationship of central deflection δ to central creep strain ε c of a specimen subjected to creep can be represented approximately by the relationship of central deflection δ to central (elastic-plastic) strain ε of a specimen not subjected to creep. With this hypothesis, the δ∼ε c relation of the small punch creep specimen is obtained by resorting to a rigid-plastic membrane stretch forming model. Finally, small punch creep test results are used to evaluate creep strain and creep strain rate by taking advantage of this δ∼ε c relation

  4. Condition For Strain-Hardening In Ecc Uniaxial Test Specimen

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    and infinite sheets under uniaxial tension. The crack is assumed to be cohesive and the cohesive law applied takes into account fiber as well as mortar properties. It is shown that the maximum crack opening observed during crack propagation in various test specimen geometries is small, 20 m and also small......This paper discusses the adequateness of the steady state flat crack criterion for crack propagation in Engineered Cementitious Composites. The investigation is performed by use of a semi-analytical model as well as a Finite Element Model. The simulations are for one crack propagating in finite...

  5. Method and Apparatus for Measuring Thermal Conductivity of Small, Highly Insulating Specimens

    Science.gov (United States)

    Miller, Robert A (Inventor); Kuczmarski, Maria A (Inventor)

    2013-01-01

    A method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable.

  6. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  7. Biaxial Testing of 2195 Aluminum Lithium Alloy Using Cruciform Specimens

    Science.gov (United States)

    Johnston, W. M.; Pollock, W. D.; Dawicke, D. S.; Wagner, John A. (Technical Monitor)

    2002-01-01

    A cruciform biaxial test specimen was used to test the effect of biaxial load on the yield of aluminum-lithium alloy 2195. Fifteen cruciform specimens were tested from 2 thicknesses of 2195-T8 plate, 0.45 in. and 1.75 in. These results were compared to the results from uniaxial tensile tests of the same alloy, and cruciform biaxial tests of aluminum alloy 2219-T87.

  8. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  9. Miniaturization of specimens for mechanical testing

    International Nuclear Information System (INIS)

    Harling, O.K.; Kohse, G.

    1987-01-01

    The development of mechanical property tests based on bending of a 3 mm diameter by (typically) 0.25 mm thick disk is described. Slow strain rate testing of such a disk is used to obtain tensile properties. Finite element computer modelling is used to extract yield stress values with accuracies of at least +- 10% of uniaxial tensile test values for a variety of materials. Analytical estimates of ductility from disk bend test values are possible for low-ductility materials. Work directed toward finite element calculations for ductility and ultimate tensile strength is also discussed. Preliminary data indicating the feasibility of high strain rate testing for estimation of ductile-to-brittle transition temperatures, and an example of the successful application of miniature bend testing in obtaining relative fatigue information are also presented. (author)

  10. Post-deformation examination of specimens subjected to SCC testing

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  11. Improved PID control for triaxial testing liquefied specimen

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Using a frictionless triaxial apparatus, sand specimens can be tested at relatively high axial strains, even while liquefying. However, liquefying specimens have extremely nonlinear stiffness, thus standard PID control does not perform well. To maintain control over applied loads, the PID...... controller was modified to adapt to disturbed soil states. The proposed methods expand the scope of testing towards options which are otherwise inaccessible by triaxial testing....

  12. 46 CFR 54.05-5 - Toughness test specimens.

    Science.gov (United States)

    2010-10-01

    ... shown in Figure 4 of the specification. Special attention is drawn to the fact that the Charpy Keyhole....090-inch. In preparing weld specimens for dropweight testing, weld reinforcement shall be ground flush...

  13. Influence of thermal conditioning media on Charpy specimen test temperature

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Swain, R.L.; Berggren, R.G.

    1989-01-01

    The Charpy V-notch (CVN) impact test is used extensively for determining the toughness of structural materials. Research programs in many technologies concerned with structural integrity perform such testing to obtain Charpy energy vs temperature curves. American Society for Testing and Materials Method E 23 includes rather strict requirements regarding determination and control of specimen test temperature. It specifies minimum soaking times dependent on the use of liquids or gases as the medium for thermally conditioning the specimen. The method also requires that impact of the specimen occur within 5 s removal from the conditioning medium. It does not, however, provide guidance regarding choice of conditioning media. This investigation was primarily conducted to investigate the changes in specimen temperature which occur when water is used for thermal conditioning. A standard CVN impact specimen of low-alloy steel was instrumented with surface-mounted and embedded thermocouples. Dependent on the media used, the specimen was heated or cooled to selected temperatures in the range -100 to 100 degree C using cold nitrogen gas, heated air, acetone and dry ice, methanol and dry ice, heated oil, or heated water. After temperature stabilization, the specimen was removed from the conditioning medium while the temperatures were recorded four times per second from all thermocouples using a data acquisition system and a computer. The results show that evaporative cooling causes significant changes in the specimen temperatures when water is used for conditioning. Conditioning in the other media did not result in such significant changes. The results demonstrate that, even within the guidelines of E 23, significant test temperature changes can occur which may substantially affect the Charpy impact test results if water is used for temperature conditioning. 7 refs., 11 figs

  14. Small test SDHW systems

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    Three small test SDHW systems was tested in a laboratory test facility.The three SDHW systems where all based on the low flow principe and a mantle tank but the design of the systems where different.......Three small test SDHW systems was tested in a laboratory test facility.The three SDHW systems where all based on the low flow principe and a mantle tank but the design of the systems where different....

  15. On impact testing of subsize Charpy V-notch type specimens

    International Nuclear Information System (INIS)

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  16. Progress Report on Alloy 617 Notched Specimen Testing

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  17. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  18. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  19. An acceleration test for stress corrosion cracking using humped specimen

    International Nuclear Information System (INIS)

    Kamaya, Masayuki; Fukumura, Takuya; Totsuka, Nobuo

    2003-01-01

    By using the humped specimen, which is processed by the humped die, in the slow strain rate technique (SSRT) test, fracture facet due to stress corrosion cracking (SCC) can be observed in relatively short duration. Although the cold work and concentrated stress and strain caused by the characteristic shape of the specimen accelerate the SCC, to date these acceleration effects have not been examined quantitatively. In the present study, the acceleration effects of the humped specimen were examined through experiments and finite element analyses (FEA). The experiments investigated the SCC of alloy 600 in the primary water environment of a pressurized water reactor. SSRT tests were conducted using two kinds of humped specimen: one was annealed after hump processing in order to eliminate the cold work, and the other was hump processed after the annealing treatment. The work ratio caused by the hump processing and stress/strain conditions during SSRT test were evaluated by FEA. It was found that maximum work ratio of 30% is introduced by the hump processing and that the distribution of the work ratio is not uniform. Furthermore, the work ratio is influenced by the friction between the specimen and dies as well as by the shape of dies. It was revealed that not only the cold work but also the concentrated stress and strain during SSRT test accelerate the crack initiation and growth of the SCC. (author)

  20. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  1. Fracture toughness evaluation using small specimens for assuring structural integrity of PRV's

    International Nuclear Information System (INIS)

    Lee, Bong Sang; Hong, J. H.; Chi, S. H.; Kim, J. H.; Yang, W. J.

    1999-08-01

    This report summarizes the results obtained from the three year contribution of KAERI to the IAEA-CRP on ''Assuring Structural Integrity of Reactor Pressure Vessels''. The mandatory part of this programme is to perform fracture toughness K jc tests using pre-cracked Charpy specimens on the IAEA reference material JRQ (ASTM A533-B1 steel). The results will be used to validate the small specimens for surveillance tests. In this report, three different heats of reactor pressure vessel materials are characterized by the ASTM E 1921-97 s tandard test method for determination of reference temperature, T o , for ferritic steels in the transition range . The materials are the IAEA reference plate (JRQ), a Japanese forging (JEL), and a Korean forging (KFY5). 6 refs., 7 tabs., 20 figs

  2. Laser weld reconstitution of conventional Charpy and Miniaturized Notch Test (MNT) specimens

    International Nuclear Information System (INIS)

    Manahan, M.P.; Williams, J.; Martukanitz, R.P.

    1993-01-01

    As nuclear power plants approach end-of-license (EOL) and consideration is given to license renewal, there is an ever increasing need to expand the amount of data obtainable from the original surveillance specimens. A laser welding technique to reconstitute broken Charpy specimens is being developed to produce both conventional and miniaturized Charpy specimens. This paper reports on early laser welding development efforts and summarizes previous proof-of-principle experiments on a 1/16 scale miniaturized Charpy test. In order to benchmark the laser welding procedure, the laser-reconstituted specimen data have been compared with the original specimen data. In addition, the microstructure after welding has been examined to ensure that the material in the vicinity of the notch is essentially unchanged after the welding process. Data which characterize the thermal transient during welding are obtained by attaching thermocouples to the specimens. Other important considerations include perturbation of the stress field near the notch, dynamic stress waves, and contact of the weld region with the tup. Precise control of welding parameters has been demonstrated, heat-affected zones as small as 0.25 mm can be achieved, and sufficient penetration depth can be obtained to enable welding thick sections (1T or greater) to yield conventional Charpy specimens or fracture toughness specimens and thin sections (∼5 mm) to yield Miniaturized Notch Test (MNT) specimens

  3. Catalogue of test specimens for non-destructive examination

    International Nuclear Information System (INIS)

    1985-05-01

    One of the key elements in assuring the integrity of reactor primary circuits is the availability of trustworthy non-destructive methods for detecting dangerous defects that may be present. Various approaches to making such examinations are being developed, including the use of ultrasonic and radiographic techniques. To demonstrate their capability and reliability, they must be tested on steel specimens reproducing the various types of faults which may arise in real primary circuit vessels and piping. Such specimens are costly to fabricate. It is therefore clearly desirable that existing specimens should be made accessible to as many organisations as possible for testing. This catalogue contains detailed Information on forty-odd deliberately flawed plates, blocks, vessels, etc. which have been produced in OECD countries, along with the name of a contact person to whom inquiries should be directed in each case

  4. Polystyrene cryostat facilitates testing tensile specimens under liquid nitrogen

    Science.gov (United States)

    Shogan, R. P.; Skalka, R. J.

    1967-01-01

    Lightweight cryostat made of expanded polystyrene reduces eccentricity in a tensile system being tested under liquid nitrogen. The cryostat is attached directly to the tensile system by a special seal, reducing misalignment effects due to cryostat weight, and facilitates viewing and loading of the specimens.

  5. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  6. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  7. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  8. Progress report on irradiation experiment on small size specimens in high temperature flux module

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, M.; Jacquet, P.; Chaouadi, R.

    2011-02-15

    This report describes the progress made in IFREC/DEMO Research and Development Program during the year 2010 at SCK/CEN. This task is part of demonstrating the possibility to irradiate small specimens in the HFTM modules that will be used in DEMO. Different small specimens of three candidate materials of DEMO fusion reactor will be irradiated with the objective of validating the specimen geometry and size to reliably characterize the mechanical properties of unirradiated and in future of irradiated materials.

  9. Guidebook for the fabrication of non-destructive testing (NDT) test specimens

    International Nuclear Information System (INIS)

    2001-01-01

    Non-destructive testing (NDT) test specimens constitute a very important part of training and certification of NDT personnel and are important for carrying out actual inspection and testing, and for achieving international harmonization of NDT practices. The IAEA organized an advisory group of experts to develop a Guidebook for Fabrication of NDT Test Specimens. The experts consulted the ISO/FDIS 9712-1999 requirements for training and certification of personnel and the suitability of various types of NDT test specimens that are needed to meet such requirements This guidebook presents a set of NDT test specimens, and the methodology and procedures for their fabrication

  10. Fracture toughness evaluation of small notched specimen in consideration of notch effect and loading rate

    International Nuclear Information System (INIS)

    Lee, Baik Woo; Kwon, Dong Il; Jang, Jae Il

    2000-01-01

    Notch effect and loading rate dependency on fracture toughness were considered when evaluating fracture toughness of small notched specimens using the instrumented impact test. Notch effect was analyzed into stress redistribution effect and stress relaxation with a viewpoint of stress triaxiality. Stress redistribution effect was corrected by introducing effective crack length, which was the sum of actual crack length and plastic zone size. Stress relaxation effect was also corrected using elastic stress concentration factor, which would decrease if plastic deformation occurred. As a result, corrected fracture toughness of the notched specimen was very consistent with the reference fracture toughness obtained using precracked specimen. In addition, limiting notch root radius, below which fracture toughness was independent of notch radius, was observed and discussed. Loading rate dependency on fracture toughness, which was obtained from the static three point bending test and the instrumented impact test, was also discussed with stress field in plastic zone ahead of a notch and fracture based on stress control mechanism. (author)

  11. Miniature specimen technology for postirradiation fatigue crack growth testing

    International Nuclear Information System (INIS)

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  12. Test of large-scale specimens and models as applied to NPP equipment materials

    International Nuclear Information System (INIS)

    Timofeev, B.T.; Karzov, G.P.

    1993-01-01

    The paper presents the test results on low-cycle fatigue, crack growth rate and fracture toughness of large-scale specimens and structures, manufactured from steel, widely applied in power engineering industry and used for the production of NPP equipment with VVER-440 and VVER-1000 reactors. The obtained results are compared with available test results of standard specimens and calculation relations, accepted in open-quotes Calculation Norms on Strength.close quotes At the fatigue crack initiation stage the experiments were performed on large-scale specimens of various geometry and configuration, which permitted to define 15X2MFA steel fracture initiation resistance by elastic-plastic deformation of large material volume by homogeneous and inhomogeneous state. Besides the above mentioned specimen tests in the regime of low-cycle loading, the test of models with nozzles were performed and a good correlation of the results on fatigue crack initiation criterium was obtained both with calculated data and standard low-cycle fatigue tests. It was noted that on the Paris part of the fatigue fracture diagram a specimen thickness increase does not influence fatigue crack growth resistance by tests in air both at 20 and 350 degrees C. The estimation of the comparability of the results, obtained on specimens and models was also carried out for this stage of fracture. At the stage of unstable crack growth by static loading the experiments were conducted on specimens of various thickness for 15X2MFA and 15X2NMFA steels and their welded joints, produced by submerged arc welding, in as-produced state (the beginning of service) and after embrittling heat treatment, simulating neutron fluence attack (the end of service). The obtained results give evidence of the possibility of the reliable prediction of structure elements brittle fracture using fracture toughness test results on relatively small standard specimens. 35 refs., 23 figs

  13. Fracture Testing with Surface Crack Specimens. [especially the residual tensile strength test

    Science.gov (United States)

    Orange, T. W.

    1974-01-01

    Recommendations are given for the design, preparation, and static fracture testing of surface crack specimens. The recommendations are preceded by background information including discussions of stress intensity factors, crack opening displacements, and fracture toughness values associated with surface crack specimens. Cyclic load and sustained load tests are discussed briefly.

  14. Analysis of the applicability of fracture mechanics on the basis of large scale specimen testing

    International Nuclear Information System (INIS)

    Brumovsky, M.; Polachova, H.; Sulc, J.; Anikovskij, V.; Dragunov, Y.; Rivkin, E.; Filatov, V.

    1988-01-01

    The verification is dealt with of fracture mechanics calculations for WWER reactor pressure vessels by large scale model testing performed on the large testing machine ZZ 8000 (maximum load of 80 MN) in the Skoda Concern. The results of testing a large set of large scale test specimens with surface crack-type defects are presented. The nominal thickness of the specimens was 150 mm with defect depths between 15 and 100 mm, the testing temperature varying between -30 and +80 degC (i.e., in the temperature interval of T ko ±50 degC). Specimens with a scale of 1:8 and 1:12 were also tested, as well as standard (CT and TPB) specimens. Comparisons of results of testing and calculations suggest some conservatism of calculations (especially for small defects) based on Linear Elastic Fracture Mechanics, according to the Nuclear Reactor Pressure Vessel Codes which use the fracture mechanics values from J IC testing. On the basis of large scale tests the ''Defect Analysis Diagram'' was constructed and recommended for brittle fracture assessment of reactor pressure vessels. (author). 7 figs., 2 tabs., 3 refs

  15. LOCA scenario tests of irradiated fuel rod specimens

    International Nuclear Information System (INIS)

    Scott, Harold

    2004-01-01

    Full text: The NRC's cladding performance program at Argonne National Laboratory (ANL) is testing fueled high-burnup segments subjected to LOCA integral phenomena. The data are provided to NRC and the nuclear industry for their independent assessment of the adequacy of licensing criteria for LOCA events. The tests are being conducted with high-burnup 30 cm segments from Limerick (9x9 Zry-2) and H.B. Robinson (15x15 Zry-4) reactors. Prior to testing, sibling samples are characterized with respect to fuel morphology, fuel-cladding bond, cladding oxide layer thickness, hydrogen content and high-temperature steam oxidation kinetics. Specimens that survive quench are subjected to four-point bend tests, followed by local diametral compression tests. The retention of post-quench ductility is a more limiting requirement than surviving thermal stresses during quench. Companion tests are conducted with unirradiated cladding to generate baseline data for comparison with the high-burnup fuel results. LOCA integral tests have the following sequential steps: stabilization of temperature, internal pressure and steam flow at 300 C, ramping of temperature (∼5C/s) through ballooning and burst to 1204 C, hold at 1204 C for 1-5 minutes, slow-cooling (∼3C/s) to 800 C, and water quenching at ∼800C. Two high-burnup tests were completed in 2002 with Limerick BWR rod segments: ramp to burst in argon followed by slow cooling; and the LOCA test with 5-minute hold time at 1204 C, followed by slow cooling. With the exception of burst-opening shape, results for burst temperature, burst pressure, burst length, and ballooning strain profile are more similar to, than different from, results for unirradiated Zry-2 cladding exposed to the same time-temperature history. The 3rd Limerick test with quench was performed in December 2003, and a 4th Limerick test was performed in March 2004. Tests on high-burnup Robinson PWR fuel segments are scheduled to begin in June 2004. The presentation points

  16. Quality assurance of the reactor pressure vessel of nuclear power plants. Determination of the fracture toughness KIC above the ductile-brittle transition region on small test specimens by means of a conformal mapping

    International Nuclear Information System (INIS)

    Ullrich, G.; Krompholz, K.

    1994-01-01

    The ''surveillance-programs'' for the determination of the mechanical properties of reactor pressure vessel (RPV) materials, as a function of the neutron dose, include impact and tensile tests for the boiling water reactor; while for pressurized water reactors additional wedge opening load specimens (WOL), for the measurement of the fracture toughness K IC at low temperatures, are utilized. While the Charpy impact toughness gives the total magnitude of energy, which indicates the change of the material state, e.g. the state of embrittlement, the fracture toughness, I IC , gives a base for mechanical calculations. This is of importance for components in which cracks or flaws are assumed. The mechanical analysis, and its relevance to safety assessments, depends on the knowledge of different parameters such as geometry of the structure and flaws, and load history of the structure. Fracture mechanical methods play an important role, if the leak-before-fracture problem is considered. Within the frame work of fracture mechanical methods, only the influence of assumed macroscopic cracks on the structural behaviour can be handled. Flaw formation processes in flaw-free structures, as well as the treatment of short flaws, can not currently be included. In the regime of low and intermediate temperatures (for ferritic and austenitic materials, normally below 400 o C), the rules of linear elastic fracture mechanics (LEFM) and elasto-plastic fracture mechanics (EPFM) are applied, some of which are already part of the code cases. (author) 5 figs., 32 refs

  17. Small specimen test results and application of advanced models for fracture mechanics assessment of RPV integrity; Ergebnisse von Kleinproben und Anwendung von Modellansaetzen zur bruchmechanischen Bewertung der RDB-Integritaet

    Energy Technology Data Exchange (ETDEWEB)

    Keim, Elisabeth; Huemmer, Matthias [AREVA NP GmbH (Germany); Hoffmann, Harald [VGB (Germany); Nagel, Gerhard [e-on Kernkraft (Germany); Kuester, Karin [VENE (Germany); Koenig, Guenter; Ilg, Ulf [EnBW (Germany); Widera, Martin [RWE (Germany); Rebsamen, Daniel [KKW Goesgen (Germany)

    2008-07-01

    For the RPV (reactor pressure vessel) integrity assessment the transferability of specimen test results to components is of main importance. The international project TIMES (transferability of fracture toughness of irradiated materials to components and structures) is focussed on the transferability of fracture mechanical characteristics of irradiated materials to components or structures, in order to allow the quantification of differences between sample and component characteristics based on experiments and calculations. The studies were performed for the brittle and brittle-ductile regions of the material characteristics using specimens from original RPV materials in different conditions. Based on case studies the consequence of a component assessment with postulated defects are shown when specimen-related materials properties are used. Since it is not possible to prove the transferability for an RPV in detail, component-similar effects were investigated that allow in combination with numerical modelling to quantify the safety margin. Samples and experimental procedures were developed that simulated the real component situation. The effects of crack depth and multiaxial loads, relevant for real components, were investigated with these samples. A micromechanical model was developed based on the weakest link theory and the statistical failure probability; this model is used for the prediction of fracture toughness of samples and components with defects. For a component with postulated defects the safety margin was assessed using different methodologies, based on standard fracture mechanical samples, taking into account component specific aspects. [German] Fuer die Bewertung der RDB-Integritaet ist die Uebertragbarkeit von Probenkennwerten auf Bauteile von grosser Bedeutung. Dazu wurde das Projekt ''TIMES'' - ein internationales Projekt zur Uebertragbarkeit von Bruchzaehigkeitskennwerten von bestrahlten Materialien auf Komponenten und Strukturen - durchgefuehrt, um

  18. Standard practice for preparing, cleaning, and evaluating corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers suggested procedures for preparing bare, solid metal specimens for tests, for removing corrosion products after the test has been completed, and for evaluating the corrosion damage that has occurred. Emphasis is placed on procedures related to the evaluation of corrosion by mass loss and pitting measurements. (Warning—In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 1 and 7.2.

  19. Metallographic analysis of irradiated RERTR-3 fuel test specimens

    International Nuclear Information System (INIS)

    Meyer, M. K.; Hofman, G. L.; Strain, R. V.; Clark, C. R.; Stuart, J. R.

    2000-01-01

    The RERTR-3 irradiation test was designed to investigate the irradiation behavior of aluminum matrix U-MO alloy dispersion fuels under high-temperature, high-fission-rate conditions. Initial postirradiation examination of RERTR-3 fuel specimens has concentrated on binary U-MO atomized fuels. The rate of matrix aluminum depletion was found to be higher than predictions based on low temperature irradiation data. Wavelength Dispersive X-ray Spectroscopy (WDS) indicates that aluminum is present in the interior of the fuel particles. WDS data is supported by a mass and volume balance calculation performed on the basis of image analysis results. The depletion of matrix aluminum seems to have no detrimental effects on fuel performance under the conditions tested to date

  20. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  1. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  2. Hydrogen embrittlement of titanium tested with fracture mechanics specimens

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Rahko, P.

    1990-11-01

    Titanium is one of the possible canister materials for spent nuclear fuel. The aim of this study is to determine whether the hydrogen embrittlement of titanium could be a possible deterioration mechanism of titanium canisters. This experimental study was preceded by a literature review and an experimental study on crack nucleation. Tests in this study were carried out with hydrogen charged fracture mechanics specimens. The studied hydrogen contents were as received, 100 ppm, 200 ppm, 500 ppm and 700 ppm and the types of the studied titanium were ASTM Grades 2 and 12. Test methods were slow tensile test (0.027 mm/h) and fatigue test (stress ratio 0.7 or 0.8 and frequency 5 Hz). According to the literature titanium may be embrittled by hydrogen at slow strain rates and cracking may occur under sustained load. In this study no evidence of hydrogen embrittlement was noticed in slow strain rate tension with bulk hydrogen contents up to 700 ppm. The fatigue tests of titanium Grades 2 and 12 containing 700 ppm hydrogen showed even slower crack growth compared to the as received condition. Very high hydrogen contents well in eccess of 700 ppm on the surface of titanium can, however, facilitate surface crack nucleation and crack growth, as shown in the previous study

  3. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  4. Study of brittle fracture in thick walled structures using small and large specimens

    International Nuclear Information System (INIS)

    Norrthon, J.-O.; Carlsson, J.

    1979-01-01

    A Russian pressure vessel steel has been investigated for fracture toughness data, Ksub(Ic) and Jsub(Ic). Four large specimens have been tested and the results correlated to data from several smaller specimens. Onset of crack growth has been detected by a high frequency electric method. (author)

  5. Design of a radiation facility for very small specimens used in radiobiology studies

    Science.gov (United States)

    Rodriguez, Manuel; Jeraj, Robert

    2008-06-01

    A design of a radiation facility for very small specimens used in radiobiology is presented. This micro-irradiator has been primarily designed to irradiate partial bodies in zebrafish embryos 3-4 mm in length. A miniature x-ray, 50 kV photon beam, is used as a radiation source. The source is inserted in a cylindrical brass collimator that has a pinhole of 1.0 mm in diameter along the central axis to produce a pencil photon beam. The collimator with the source is attached underneath a computer-controlled movable table which holds the specimens. Using a 45° tilted mirror, a digital camera, connected to the computer, takes pictures of the specimen and the pinhole collimator. From the image provided by the camera, the relative distance from the specimen to the pinhole axis is calculated and coordinates are sent to the movable table to properly position the samples in the beam path. Due to its monitoring system, characteristic of the radiation beam, accuracy and precision of specimen positioning, and automatic image-based specimen recognition, this radiation facility is a suitable tool to irradiate partial bodies in zebrafish embryos, cell cultures or any other small specimen used in radiobiology research.

  6. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  7. Small Engine & Accessory Test Area

    Data.gov (United States)

    Federal Laboratory Consortium — The Small Engine and Accessories Test Area (SEATA) facilitates testaircraft starting and auxiliary power systems, small engines and accessories. The SEATA consists...

  8. Growth behavior of fatigue cracks in ultrafine grained Cu smooth specimens with a small hole

    Directory of Open Access Journals (Sweden)

    Masahiro Goto

    2015-10-01

    Full Text Available In order to study the growth mechanism of fatigue cracks in ultrafine grained copper, stresscontrolled fatigue tests of round-bar specimens with a small blind hole as a crack starter were conducted. The hole was drilled on the surface where an intersection between the shear plane of the final ECAP processing and the specimen surface makes an angle of 45° or 90° with respect to the loading axis. At a low stress (  a = 90 MPa, the direction of crack paths was nearly perpendicular to the loading direction regardless of the location of the hole. Profile of crack face was examined, showing the aspect ratio (b/a of b/a = 0.82. At a high stress (  a = 240 MPa, although the growth directions inclined 45° and 90° to the loading-axis were observed depending on the location of the drilling hole, crack faces in these cracks were extended along one set of maximum shear stress planes, corresponding to the final ECAP shear plane. The value of aspect ratios was b/a = 0.38 and 1.10 for the cracks with 45° and 90° inclined path directions, respectively. The role of deformation mode at the crack tip areas on crack growth behavior were discussed in terms of the mixed-mode stress intensity factor. The crack path formation at high stress amplitudes was affected by the in-plane shear-mode deformation at the crack tip.

  9. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  10. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  11. Application of small specimens to fracture mechanics characterization of irradiated pressure vessel steels

    International Nuclear Information System (INIS)

    Sokolov, M.A.; Wallin, K.; McCabe, D.E.

    1996-01-01

    In this study, precracked Charpy V-notch (PCVN) specimens were used to characterize the fracture toughness of unirradiated and irradiated reactor pressure vessel steels in the transition region by means of three-point static bending. Fracture toughness at cleavage instability was calculated in terms of elastic-plastic K Jc values. A statistical size correction based upon weakest-link theory was performed. The concept of a master curve was applied to analyze fracture toughness properties. Initially, size-corrected PCVN data from A 533 grade B steel, designated HSST Plate O2, were used to position the master curve and a 5% tolerance bound for K Jc data. By converting PCVN data to IT compact specimen equivalent K Jc data, the same master curve and 5% tolerance bound curve were plotted against the Electric Power Research Institute valid linear-elastic K Jc database and the ASME lower bound K Ic curve. Comparison shows that the master curve positioned by testing several PCVN specimens describes very well the massive fracture toughness database of large specimens. These results give strong support to the validity of K Jc with respect to K Ic in general and to the applicability of PCVN specimens to measure fracture toughness of reactor vessel steels in particular. Finally, irradiated PCVN specimens of other materials were tested, and the results are compared to compact specimen data. The current results show that PCVNs demonstrate very good capacity for fracture toughness characterization of reactor pressure vessel steels. It provides an opportunity for direct measurement of fracture toughness of irradiated materials by means of precracking and testing Charpy specimens from surveillance capsules. However, size limits based on constraint theory restrict the operational test temperature range for K Jc data from PCVN specimens. 13 refs., 8 figs., 1 tab

  12. Fracture toughness behaviour using small CCT specimen of Zr-2.5Nb pressure tube materials

    International Nuclear Information System (INIS)

    Oh, Dong Joon; Kim, Young Suk; Ahn, Sang Bok; Im, Kyung Soo; Kwon, Sang Chul; Cheong, Yong Mu

    2001-03-01

    Fracture toughness of Zr-2.5Nb pressure tube is the essential data to estimate the CCL(critical crack length) for the concept of LBB(Leak-Before-Break) in PHWR. Zr-2.5Nb pressure tubes could be degraded due to the absorption of hydrogen from coolant and the irradiation. To investigate the fracture toughness behaviour such as J-resistance curves, dJ/da, and CCL of some Zr-alloys (CANDU-double, -quad, CW-E125, TMT-E125, E-635), the transverse tensile test and the fracture toughness test of small CCT (Curved Compact Tension) specimen with 17 mm width were carried out with the variation of testing temperature at different testing condition. To define the fracture mechanism of degradation, the fractographic comparison of fracture surface was performed using the stereoscope and SEM. In addition, the effect of non-uniformed pre-fatigue crack was also studied. In conclusion, CANDU double-melted was less tougher than CANDU quad-melted and the hydrogen embrittlement was found at room temperature. Finally, while the effect of non-uniformed pre-fatigue crack was considerable at room temperature, this effect was disappeared at 250-300 .deg. C

  13. Small Punch Test Techniques for Irradiated Materials in Hot Cell

    International Nuclear Information System (INIS)

    Kim, Do Sik; Ahn, S. B.; Oh, W. H.; Yoo, B. O.; Choo, Y. S.

    2006-06-01

    Detailed procedures of the small punch test including the apparatus, the definition of small punch-related parameters, and the interpretation of results were presented. The testing machine should have a capability of the compressive loading and unloading at a given deflection level. The small punch specimen holder consists of an upper and lower die and clamping screws. The clamped specimen is deformed by using ball or spherical head punch. Two type of specimens with a circular and a square shape were used. The irradiated small punch specimen is made from the undamaged portion of the broken CVN bars or prepared by the irradiation of the specimen fabricated from the fresh materials. The heating and cooling devices should have the capability of the temperature control within ±2 .deg. C for the target value during the test. Based on the load-deflection data obtained from the small punch test. the empirical correlation between the small punch related parameters and a tensile properties such as 0.2% yield strength and ultimate tensile strength, fracture toughness, ductile-brittle transition temperature and creep properties determined from the standard test method is established and used to evaluate the mechanical properties of an irradiated materials. In addition, from the quantitative fractographic assessment of small punch test specimens, the relationship between the small punch energy and the quantity of ductile crack growth is obtained. Analytical formulations demonstrated good agreement with experimental load-deflection curves

  14. An Inset CT Specimen for Evaluating Fracture in Small Samples of Material

    Science.gov (United States)

    Yahyazadehfar, M.; Nazari, A.; Kruzic, J.J.; Quinn, G.D.; Arola, D.

    2013-01-01

    In evaluations on the fracture behavior of hard tissues and many biomaterials, the volume of material available to study is not always sufficient to apply a standard method of practice. In the present study an inset Compact Tension (inset CT) specimen is described, which uses a small cube of material (approximately 2×2×2 mm3) that is molded within a secondary material to form the compact tension geometry. A generalized equation describing the Mode I stress intensity was developed for the specimen using the solutions from a finite element model that was defined over permissible crack lengths, variations in specimen geometry, and a range in elastic properties of the inset and mold materials. A validation of the generalized equation was performed using estimates for the fracture toughness of a commercial dental composite via the “inset CT” specimen and the standard geometry defined by ASTM E399. Results showed that the average fracture toughness obtained from the new specimen (1.23 ± 0.02 MPa•m0.5) was within 2% of that from the standard. Applications of the inset CT specimen are presented for experimental evaluations on the crack growth resistance of dental enamel and root dentin, including their fracture resistance curves. Potential errors in adopting this specimen are then discussed, including the effects of debonding between the inset and molding material on the estimated stress intensity distribution. Results of the investigation show that the inset CT specimen offers a viable approach for studying the fracture behavior of small volumes of structural materials. PMID:24268892

  15. Special fracture mechanics specimens for multilayer plastic pipes testing

    Czech Academy of Sciences Publication Activity Database

    Hutař, Pavel; Šestáková, Lucie; Knésl, Zdeněk; Nezbedová, E.; Náhlík, Luboš

    2009-01-01

    Roč. 28, č. 8 (2009), s. 785-792 ISSN 0142-9418 R&D Projects: GA ČR GA106/09/0279; GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : Multilayer plastic pipes * C-type specimen * K-calibration * Fracture toughness * Slow crack growth * Non-homogenous specimens Subject RIV: JL - Material s Fatigue, Friction Mechanics Impact factor: 1.667, year: 2009

  16. New specimen design for studying the growth of small fatigue cracks with surface acoustic waves

    Science.gov (United States)

    London, Blair

    1985-08-01

    The study of small surface fatigue cracks in AISI 4140 quenched and tempered steel by a nondestructive surface acoustic wave technique is summarized. A novel cantilevered bending, plate-type fatigue specimen is described that is compatible with the acoustic method. Small cracks are initiated from a 25-μm deep surface pit produced by an electrospark machine. The importance of studying these cracks which closely approximate naturally occurring fatigue cracks is briefly discussed.

  17. Development of stress relaxation measurement by a small size C-ring specimen method

    International Nuclear Information System (INIS)

    Shimanuki, Shizuka; Nakata, Kiyotomo; Kasahara, Shigeki; Kuniya, Jiro

    2002-01-01

    A stress relaxation measurement method has been developed by using C-ring specimens, and a specimen size effect has been evaluated taking radiation-induced stress relaxation into consideration. C-ring specimens were stressed by forcing a wedge in the gap. Giving an appropriate eccentric configuration in the half of the ring opposite the gap, the stress gradient along the circumference was eliminated in the section and the stress level could be varied by changing the gap spacing. The validity of the C-ring test method was confirmed by thermally stress relaxation experiments at annealing temperatures from 300 to 600degC for 1 min to 200 h in carbon steel: considerable stress relaxation could be measured for all levels of applied stress even at relatively low annealing temperatures. The relaxation results obtained from the C-ring test were in good agreement with those from a uniaxial tensile stress relaxation test. The smaller C-ring specimen with about 40 mm diameter, which is required for radiation-induced stress relaxation test, also showed adequate accuracy on stress relaxation at 600 to 830degC in stainless steel, compared with the large size C-ring specimen test. (author)

  18. Digitizing specimens in a small herbarium: A viable workflow for collections working with limited resources.

    Science.gov (United States)

    Harris, Kari M; Marsico, Travis D

    2017-04-01

    Small herbaria represent a significant portion of herbaria in the United States, but many are not digitizing their collections. At the Arkansas State University Herbarium (STAR), we have created a viable workflow to help small herbaria begin the digitization process, including suggestions for publishing data on the Internet. We calculated hourly rates of each phase of the digitization process. We also mapped accessions at the county level to determine geographic strengths in the collection. All 17,678 accessioned flowering plant specimens at STAR are imaged, databased in Specify, and available electronically on the herbarium's website. Students imaged the specimens at a mean rate of 145/h. We found differences in databasing rates between the graduate student leading the project (47/h) and undergraduate assistants (25/h). The majority of specimens at STAR were collected within the counties neighboring the institution. With this workflow, we estimate that one person can digitize a 20,000-specimen collection in less than 2.5 yr by working only 10 h/wk. Because STAR is a small herbarium with limited resources, the application of the workflow described should assist curators of similar-sized collections as they contemplate and undertake the digitization process.

  19. Digitizing specimens in a small herbarium: A viable workflow for collections working with limited resources1

    Science.gov (United States)

    Harris, Kari M.; Marsico, Travis D.

    2017-01-01

    Premise of the study: Small herbaria represent a significant portion of herbaria in the United States, but many are not digitizing their collections. Methods: At the Arkansas State University Herbarium (STAR), we have created a viable workflow to help small herbaria begin the digitization process, including suggestions for publishing data on the Internet. We calculated hourly rates of each phase of the digitization process. We also mapped accessions at the county level to determine geographic strengths in the collection. Results: All 17,678 accessioned flowering plant specimens at STAR are imaged, databased in Specify, and available electronically on the herbarium’s website. Students imaged the specimens at a mean rate of 145/h. We found differences in databasing rates between the graduate student leading the project (47/h) and undergraduate assistants (25/h). The majority of specimens at STAR were collected within the counties neighboring the institution. Discussion: With this workflow, we estimate that one person can digitize a 20,000-specimen collection in less than 2.5 yr by working only 10 h/wk. Because STAR is a small herbarium with limited resources, the application of the workflow described should assist curators of similar-sized collections as they contemplate and undertake the digitization process. PMID:28439474

  20. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    movie modules. The comparison of the two sample group means of the examinations show that there was no difference in results between using QTVR movie modules to test gross anatomy knowledge versus using physical specimens. The results of this study are discussed to explain the benefits of using such computer based anatomy resources in gross anatomy assessments.

  1. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  2. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  3. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  4. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    International Nuclear Information System (INIS)

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  5. Molecular testing of human papillomavirus in cervical specimens

    International Nuclear Information System (INIS)

    Gazzaz, Faten Salah B.

    2007-01-01

    Objective was to improve the diagnosis of cervical neoplasia by early detection of human papillomavirus (HPV) in uterine cervix, by adding molecular testing of HPV using hybrid capture 2 (HC2) and polymerase chain reaction (PCR) tests to Papanicoalou (Pap) test. One hundred women were enrolled in this study. The mean age (mean+-SD) was 41.97+- 8.76 years and range was 27-65 years. All women had undergone cervical cytological screening with cervical cytology, HPV DNA testing by HC2 and PCR, during the period from January to December 2006, at King Abdul-Aziz University Hospital (KAAUH) and King Fahd research Center, Jeddah, Saudi Arabia. The results were obtained by HC2 for detection of HPV were 5(5%) high-risk HPV, one low-risk HPV (1%) and 94(94%) negative cases. The PCR detected only 4(4%) cases. Using the HC2 test as a reference, sensitivity, specificity, positive predictive, negative predictive values and accuracy of base line Pap were 50, 85, 17.7, 96.4 and 83%; of final Pap smear were 100, 96.8, 66.7, 100, and 97% and for PCR were 66.7, 100, 100, 97.9 and 98%. The Pap test was repeated within a year for patients with abnormal Pap test with positive HPV DNA. Combined screening by cytology and HPV testing using both HC2 and PCR sensitively detects women with existing disease. The absence of HPV DNA provides reassurance that patients are unlikely to develop cancer for several years. We suggest using Pap with HC2 and PCR in screening programs to ensure that women with the double negative result at baseline might safely be screened at longer intervals. (author)

  6. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  7. Gamma irradiation test report of simulated grout specimens for gas generation/liquid advection

    International Nuclear Information System (INIS)

    Hinman, C.A.

    1994-01-01

    This report presents the results from an irradiation test performed on four specimens of grout that were fabricated from synthetic Double Shell Slurry Feed (DSSF) liquid waste. The objective was to investigate the radiolytic generation of gases and the potential for advective rejection of waste liquids from the grout matrix and to provide experimental information for the validation of the C-Cubed calculated model. It has been demonstrated that a number of gases can be formed within the grout due to radiolytic decomposition of various chemical components that make up the grout. This observation leads to the conjecture that the potential exists for the rejection of a portion of the 60 vol% free liquid from the grout matrix driven by pressurization by these gases. It was found that, for the specimen geometries used in this test series, and for peak radiation dose accumulation rates on the order of 4 to 60 times of the initial rate expected in the grout vaults (300 Rads/hr), no liquid rejection was observed from 2% to 35% of the target exposure expected in the grout vaults (1E+08 Rads). When the irradiation rate exceeded the projected grout vault dose rate by a factor of 200 a small amount of liquid rejection was observed from one of two specimens that had received 20% more than the goal exposure. Because of the differences in the magnitudes of the relative radiation field strengths between this study and an actual grout vault, it is concluded that the potential for liquid rejection by internal gas pressurization from presently configured grout waste forms is very low for the expected conditions

  8. Shear Punch Testing of BOR-60 Irradiated TEM Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Tarik A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Quintana, Matthew Estevan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Tobias J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-13

    As a part of the project “High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation” an Integrated Research Program (IRP) project from the U.S. Department of Energy, Nuclear Energy University Programs (NEUP), TEM geometry samples of ferritic cladding alloys, Ni based super alloys and model alloys were irradiated in the BOR-60 reactor to ~16 dpa at ~370°C and ~400°C. Samples were sent to Los Alamos National Laboratory and subjected to shear punch testing. This report presents the results from this testing.

  9. Acquisition and preparation of specimens of rock for large-scale testing

    International Nuclear Information System (INIS)

    Watkins, D.J.

    1981-01-01

    The techniques used for acquisition and preparation of large specimens of rock for laboratory testing depend upon the location of the specimen, the type of rock and the equipment available at the sampling site. Examples are presented to illustrate sampling and preparation techniques used for two large cylindrical samples of granitic material, one pervasively fractured and one containing a single fracture

  10. Comparison of Three Different Methods for Pile Integrity Testing on a Cylindrical Homogeneous Polyamide Specimen

    Science.gov (United States)

    Lugovtsova, Y. D.; Soldatov, A. I.

    2016-01-01

    Three different methods for pile integrity testing are proposed to compare on a cylindrical homogeneous polyamide specimen. The methods are low strain pile integrity testing, multichannel pile integrity testing and testing with a shaker system. Since the low strain pile integrity testing is well-established and standardized method, the results from it are used as a reference for other two methods.

  11. Small Punch Tests applied to the nuclear industry

    International Nuclear Information System (INIS)

    Moreno, M.; Gongora, P.; Bertolino, G; Yawny, A.

    2012-01-01

    The interest on miniaturized specimen techniques for the characterization of the mechanical behavior of materials was strongly motivated in the early eighties by the different programs associated with the development of fusion reactor technology. The importance of such developments is obvious in the case of the nuclear industry where the limited space available, the presence of fluence gradients in large specimens, the concern about gamma heating and dose to personnel in post-irradiation testing have all been motivations for reducing specimen size. Testing of miniature specimen includes a wide spectrum of techniques such as tensile, instrumented micro-hardness, small punch, bend, fracture, impact and fatigue. Small Punch Testing (SPT) techniques use a spherical penetrator which deforms to failure a miniature disc shaped flat specimen (typically, 3-10 mm in diameter and 0.25-0.50 mm in thickness) supported on its outer rim. Analysis of load-displacement data recorded along the test is performed for the determination of the property of interest. The present work focuses on the characterization of the elastoplastic response of pure Al, ADN 420 structural steel and AISI 304L using SPT and its correlation with the associated standard uniaxial testing behavior. In addition, the sensitivity of the technique to the specific material under study and to different experimental parameters, i.e. specimen diameter and thickness, clearance or clamping force and friction between disc and dies have been assessed both experimentally and by performing simulations using the finite element method (author)

  12. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  13. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  14. Small punch test evaluation methods for material characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Janča, Adam, E-mail: adam.janca@fjfi.cvut.cz; Siegl, Jan, E-mail: jan.siegl@fjfi.cvut.cz; Haušild, Petr, E-mail: petr.hausild@fjfi.cvut.cz

    2016-12-01

    The Small Punch Test (SPT) is one of the most widespread mechanical testing methods using miniaturized specimens. The paper presented deals with the time independent SPT, in which a flat specimen is bent by means of a (hemi)spherical punch moving at a constant velocity. The main goal is to relate the measured data to deformation processes taking place during specimen loading. Understanding of such relations is crucial for characterizing a material using any non-standardized experimental procedure. Using enhanced instrumentation, not only traditional load-displacement or load-deflection curves could be obtained, but also specimen thinning could be continuously measured and evaluated. Five alloys having a broad range of mechanical properties were tested. The results obtained were evaluated using both traditional and newly proposed methods and they were correlated with results of the conventional tensile test. The methods proposed seem to lead to a universal correlation between SPT results and tensile characteristics. - Highlights: • The newly proposed methodology significantly improved results of SPT. • Plastic deformation starts inside the specimen from the very beginning of loading. • Specimen thinning = punch displacement−specimen deflection. • Material response to loading is well illustrated by the novel load-thinning curve.

  15. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  16. Testing machine for fatigue crack kinetic investigation in specimens under bending

    International Nuclear Information System (INIS)

    Panasyuk, V.V.; Ratych, L.V.; Dmytrakh, I.N.

    1978-01-01

    A kinematic diagram of testing mashine for the investigation of fatigue crack kinetics in prismatic specimens, subjected to pure bending is described. Suggested is a technique of choosing an optimum ratio of the parameters of ''the testing machine-specimen'' system, which provide the stabilization of the stress intensity coefficient for a certain region of crack development under hard loading. On the example of the 40KhS and 15Kh2MFA steel specimens the pliability of the machine constructed according to the described diagram and designed for the 30ONxm maximum bending moment. The results obtained can be used in designing of the testing machines for studying pure bending under hard loading and in choosing the sizes of specimens with rectangular cross sections for investigations into the kinetics of the fatigue crack

  17. Small ring testing of a creep resistant material

    International Nuclear Information System (INIS)

    Hyde, C.J.; Hyde, T.H.; Sun, W.; Nardone, S.; De Bruycker, E.

    2013-01-01

    Many components in conventional and nuclear power plant, aero-engines, chemical plant etc., operate at temperatures which are high enough for creep to occur. These include steam pipes, pipe branches, gas and steam turbine blades, etc. The manufacture of such components may also require welds to be part of them. In most cases, only nominal operating conditions (i.e. pressure, temperatures, system load, etc.) are known and hence precise life predictions for these components are not possible. Also, the proportion of life consumed will vary from position to position within a component. Hence, non-destructive techniques are adopted to assist in making decisions on whether to repair, continue operating or replace certain components. One such approach is to test a small sample removed from the component to make small creep test specimens which can be tested to give information on the remaining creep life of the component. When such a small sample cannot be removed from the operating component, e.g. in the case of small components, the component can be taken out of operation in order to make small creep test specimens, the results from which can then be used to assist with making decisions regarding similar or future components. This paper presents a small creep test specimen which can be used for the testing of particularly strong and creep resistant materials, such as nickel-based superalloys

  18. Optimization of tensile method and specimen geometry in modified ring tensile test

    International Nuclear Information System (INIS)

    Kitano, Koji; Fuketa, Toyoshi; Sasajima, Hideo; Uetsuka, Hiroshi

    2001-03-01

    Several techniques in ring tensile test are proposed in order to evaluate mechanical properties of cladding under hoop loading condition caused by pellet/cladding mechanical interaction (PCMI). In the modified techniques, variety of tensile methods and specimen geometry are being proposed in order to limit deformation within the gauge section. However, the tensile method and the specimen geometry were not determined in the modified techniques. In the present study, we have investigated the tensile method and the specimen geometry through finite element method (FEM) analysis of specimen deformation and tensile test on specimens with various gauge section geometries. In using two-piece tensile tooling, the mechanical properties under hoop loading condition can be correctly evaluated when deformation part (gauge section) is put on the top of a half-mandrel, and friction between the specimen and the half-mandrel is reduced with Teflon tape. In addition, we have shown the optimum specimen geometry for PWR 17 by 17 type cladding. (author)

  19. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  20. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How long does the laboratory retain specimens after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How...

  1. Standard practice for fracture testing with surface-crack tension specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the design, preparation, and testing of surface-crack tension (SCT) specimens. It relates specifically to testing under continuously increasing force and excludes cyclic and sustained loadings. The quantity determined is the residual strength of a specimen having a semielliptical or circular-segment fatigue crack in one surface. This value depends on the crack dimensions and the specimen thickness as well as the characteristics of the material. 1.2 Metallic materials that can be tested are not limited by strength, thickness, or toughness. However, tests of thick specimens of tough materials may require a tension test machine of extremely high capacity. The applicability of this practice to nonmetallic materials has not been determined. 1.3 This practice is limited to specimens having a uniform rectangular cross section in the test section. The test section width and length must be large with respect to the crack length. Crack depth and length should be chosen to suit the ultimate pu...

  2. Evaluation of Specimen Geometric Effect for Laser Flash Thermal Diffusivity Test

    International Nuclear Information System (INIS)

    Park, Dae Gyu; Kim, Hee Moon; Song, Woong Sub; Baik, Seung Je; Ryu, Woo Seok; Ahn, Sang Bok; Joo, Young Sun

    2012-01-01

    KAERI(Korea Atomic Energy Research Institute) is developing a new type of nuclear reactor, the so called 'SMART' (System Integrated Modular Advanced Reactor) reactor. Alloy 690 was selected as the candidate material for the heat exchanger tube of of SMART's steam generator. The SMART R and D is now facing the stage of engineering verification and standard design approval for application of DEMO reactors. Therefore, the material performance under the relevant environment needs to be evaluated. The one of the important material performance issues is thermal conductivity, which the engineering database is necessary for the steam generator design. However, the neutron post irradiation characteristics of alloy 690 are little known. As a result, a PIE (Post Irradiation Examination) of the thermal properties have been plan for a 4 times, so called base line test, 1 st irradiation test, 2 nd and 3 rd irradiation test. But there is some constraint to perform thermal diffusivity test owing to test specimen. Originally thermal diffusivity test are planed using disk shape with 9 mm diameter and 1 mm thick specimen. Due to mismatch of neutron irradiation schedule, thermal diffusivity will be tested by different shape and size specimens at 1 st irradiation test. Therefore, verification of geometric and size effect are necessary for test specimen in order to achieve accurate test results

  3. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  4. Gas and water permeability of concrete for reactor buildings small specimens

    International Nuclear Information System (INIS)

    Mills, R.H.

    1986-03-01

    The effect on permeability of artifical aging by drying shrinkage and by freeze-thaw was determined by observing mass transfer of gas and water under a pressure gradient. It was found that damage due to freeze-thaw was negligible but that cracking around aggregate caused by drying shrinkage resulted in significantly increased permeability to both gas and water. The absence of freeze-thaw damage was attributed to self-dessication. Since the concrete was not exposed to an external source of water, the chemical reaction was sustained by consumption of mixing water. The resulting air voids were, apparently, sufficient to absorb expansive pressures due to ice formation. The response to lateral prestress was different for cracked and uncracked concrete. Although, in all cases, increased prestress resulted in reduced leakage, the effect was stronger in cracked concrete. Mean pore diameter as determined by gas diffusion was not, however, substantially affected because the leakage in cracked concrete remained very low. Reinforcing steel did not have a great influence on permeability of small specimens. Gas transmission through concrete was strongly influenced by moisture content. Free moisture constituted a barrier to gas flow, acting as a virtual solid. This is important since aging of concrete results in reduced free moisture. Ultrasonic pulse velocity appeared to vary with moisture content and porosity of concrete in the same way as gas permeability and gave promise of being effective for in-situ monitoring of concrete in reactor buildings

  5. Influence of Specimen Preparation and Test Methods on the Flexural Strength Results of Monolithic Zirconia Materials.

    Science.gov (United States)

    Schatz, Christine; Strickstrock, Monika; Roos, Malgorzata; Edelhoff, Daniel; Eichberger, Marlis; Zylla, Isabella-Maria; Stawarczyk, Bogna

    2016-03-09

    The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx² (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

  6. Remote replacement of materials open-test assembly specimens at the FFTF/IEM cell

    International Nuclear Information System (INIS)

    Gibbons, P.W.; Ramsey, E.B.

    1990-01-01

    The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and materials experiments. The materials open-test assembly (MOTA) is brought to the IEM cell for materials test specimen removal. The specimens are shipped to the materials laboratory for sorting and installation in new specimen holders and then returned within 10 days to the IEM cell where they are installed in a new MOTA vehicle for further irradiation. Reconstituting a MOTA is a challenging remote operation involving dozens of steps and two separate facilities. Handling and disassembling sodium-wetted components pose interesting handling, cleaning, and disposal challenges. The success of this system is evidenced by its timely completion in the critical path of FFTF outage schedules

  7. Development of a method evaluation of deformation and fracture characteristics using small specimens

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, D. l.; Ahn, J. H.; Ju, J. B.; Choi, Y.; Lee, B. W. [Seoul National Univ., Seoul (Korea)

    2000-04-01

    In this study, the flow properties of various structural steels were estimated by analyzing the indentation load-depth curve obtained by ball indentation and the pile-up or sink-in phenomenon around indentation. The constraint factor {psi} was then related to the work-hardening characteristics of material. For various steels such as SA508, TMCP, SM50, SA213, SA106, and AISI1025, the results of indentation test were compared to those of tensile test, which shows that the present analysis can predict successfully the plastic flow properties of structural steels. In this study, in order to obtain more reliable fracture characteristics based on fracture mechanics, the pre-crack is introduced to SP specimen and acoustic emission is used to determine the crack initiation point. Using the load at crack initiation point, the fracture toughnesses of SA 508 Cl.3 steel, STS 304 stainless steel, SM 50 steel and TMCP steel were calculated successfully. 58 refs., 22 figs., 5 tabs. (Author)

  8. Experimental and Numerical Evaluation of Direct Tension Test for Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Jung J. Kim

    2014-01-01

    Full Text Available Concrete cracking strength can be defined as the tensile strength of concrete subjected to pure tension stress. However, as it is difficult to apply direct tension load to concrete specimens, concrete cracking is usually quantified by the modulus of rupture for flexural members. In this study, a new direct tension test setup for cylindrical specimens (101.6 mm in diameter and 203.2 mm in height similar to those used in compression test is developed. Double steel plates are used to obtain uniform stress distributions. Finite element analysis for the proposed test setup is conducted. The uniformity of the stress distribution along the cylindrical specimen is examined and compared with rectangular cross section. Fuzzy image pattern recognition method is used to assess stress uniformity along the specimen. Moreover, the probability of cracking at different locations along the specimen is evaluated using probabilistic finite element analysis. The experimental and numerical results of the cracking location showed that gravity effect on fresh concrete during setting time might affect the distribution of concrete cracking strength along the height of the structural elements.

  9. Validatin of miniaturised tensile testing on DMLS TI6AL4V (ELI specimens

    Directory of Open Access Journals (Sweden)

    Van Zyl, Ian

    2016-11-01

    Full Text Available Direct metal laser sintering (DMLS is a relatively new technology that is developing rapidly. Since DMLS material is created by melting/solidifying tracks and layers from powder, even building geometry can influence the mechanical properties. To certify a material, the testing specimens must be designed and manufactured according to the appropriate standards. Miniaturised tensile DMLS samples could be a good alternative for express quality control, and could reduce the cost of DMLS-specific testing. In this study, as-built and stress-relieved miniaturised tensile DMLS Ti6Al4V (ELI specimens with different surface qualities were investigated. The fracture surfaces and mechanical properties of the mini-tensile specimens were analysed and compared with standard full-sized specimens also manufactured by DMLS. The obtained data showed the applicability of mini-tensile tests for the express analysis of DMLS objects if a correction factor is applied for the calculation of the load-bearing cross-section of the specimen.

  10. Computer vision applied to herbarium specimens of German trees: testing the future utility of the millions of herbarium specimen images for automated identification.

    Science.gov (United States)

    Unger, Jakob; Merhof, Dorit; Renner, Susanne

    2016-11-16

    Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.

  11. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    Science.gov (United States)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  12. Determination of a cohesive law for delamination modelling - Accounting for variation in crack opening and stress state across the test specimen width

    DEFF Research Database (Denmark)

    Joki, R. K.; Grytten, F.; Hayman, Brian

    2016-01-01

    by differentiating the fracture resistance with respect to opening displacement at the initial location of the crack tip, measured at the specimen edge. 2) Extend the bridging law to a cohesive law by accounting for crack tip fracture energy. 3) Fine-tune the cohesive law through an iterative modelling approach so......The cohesive law for Mode I delamination in glass fibre Non-Crimped Fabric reinforced vinylester is determined for use in finite element models. The cohesive law is derived from a delamination test based on DCB specimens loaded with pure bending moments taking into account the presence of large...... that the changing state of stress and deformation across the width of the test specimen is taken into account. The changing state of stress and deformation across the specimen width is shown to be significant for small openings (small fracture process zone size). This will also be important for the initial part...

  13. COMPARISON BETWEEN WOOD DRYING DEFECT SCORES: SPECIMEN TESTING X ANALYSIS OF KILN-DRIED BOARDS

    Directory of Open Access Journals (Sweden)

    Djeison Cesar Batista

    2015-04-01

    Full Text Available It is important to develop drying technologies for Eucalyptus grandis lumber, which is one of the most planted species of this genus in Brazil and plays an important role as raw material for the wood industry. The general aim of this work was to assess the conventional kiln drying of juvenile wood of three clones of Eucalyptus grandis. The specific aims were to compare the behavior between: i drying defects indicated by tests with wood specimens and conventional kiln-dried boards; and ii physical properties and the drying quality. Five 11-year-old trees of each clone were felled, and only flatsawn boards of the first log were used. Basic density and total shrinkage were determined, and the drying test with wood specimens at 100 °C was carried out. Kiln drying of boards was performed, and initial and final moisture content, moisture gradient in thickness, drying stresses and drying defects were assessed. The defect scoring method was used to verify the behavior between the defects detected by specimen testing and the defects detected in kiln-dried boards. As main results, the drying schedule was too severe for the wood, resulting in a high level of boards with defects. The behavior between the defects in the drying test with specimens and the defects of kiln-dried boards was different, there was no correspondence, according to the defect scoring method.

  14. Stress Wave Attenuation in Aluminum Alloy and Mild Steel Specimens Under SHPB Tensile Testing

    Science.gov (United States)

    Pothnis, J. R.; Ravikumar, G.; Arya, H.; Yerramalli, Chandra S.; Naik, N. K.

    2018-02-01

    Investigations on the effect of intensity of incident pressure wave applied through the striker bar on the specimen force histories and stress wave attenuation during split Hopkinson pressure bar (SHPB) tensile testing are presented. Details of the tensile SHPB along with Lagrangian x- t diagram of the setup are included. Studies were carried out on aluminum alloy 7075 T651 and IS 2062 mild steel. While testing specimens using the tensile SHPB setup, it was observed that the force calculated from the transmitter bar strain gauge was smaller than the force obtained from the incident bar strain gauge. This mismatch between the forces in the incident bar and the transmitter bar is explained on the basis of stress wave attenuation in the specimens. A methodology to obtain force histories using the strain gauges on the specimen during SHPB tensile testing is also presented. Further, scanning electron microscope images and photomicrographs are given. Correlation between the microstructure and mechanical properties is explained. Further, uncertainty analysis was conducted to ascertain the accuracy of the results.

  15. Stress corrosion cracking tests on electron beam welded carbon steel specimens in carbonate-bicarbonate solution

    International Nuclear Information System (INIS)

    Parkins, R.N.

    1985-04-01

    Stress corrosion cracking tests have been performed on tapered carbon steel test pieces containing electron beam welds with a view to defining susceptibility to such cracking in a carbonate-bicarbonate solution at 90 C and an appropriate electrode potential. The tests involved applying cyclic loads to the specimens and it is shown that the threshold stress for cracking reduces linearly with increase in the magnitude of the cyclic load component. Extrapolation of these trends to zero fluctuating stress indicates static load threshold stresses in the vicinity of the yield stress (i.e. about 300 N/mm 2 for parent plate without a weld, 400 N/mm 2 for specimens with welds on one side only and 600 N/mm 2 for specimens having welds penetrating through the thickness of the specimen). The averages of the maximum crack velocities observed were least for parent plate material and greatest for weld metal, the former being essentially intergranular in morphology and the latter mostly transgranular, with heat affected zone material being intermediate between these extremes. (author)

  16. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  17. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  18. Constructing kinetics fatigue diagrams using testing results obtained on a machine with rigid loading for specimens of various thickness

    International Nuclear Information System (INIS)

    Simin'kovich, V.N.; Gladkij, Ya.N.; Deev, N.A.

    1981-01-01

    Bending tests of 40KhS steel specimens, tempered at 200 and 500 deg C, are conducted to investigate the possible effects of specimen thickness on fatigue crack growth. Kinetic fatigue diagrams are constructed using the investigation results. An increase in crack growth with thickness is observed only in high-tempered specimens. Changes in specimen thickness do not affect crack growth in 40KhS low-tempered steel [ru

  19. SMILE: test to validate the WPS effect with a cylindrical thick-walled specimen

    International Nuclear Information System (INIS)

    Bezdikian, G.; Moinereau, D.; Roos, E.; Kerkhof, K.; Taylor, N.

    2004-01-01

    The Reactor Pressure Vessel (RPV) is an essential component, which is liable to limit the lifetime duration of PWR plants. The assessment of defects in RPV subjected to pressurized thermal shock (PTS) transients made at an European level generally does not necessarily consider the beneficial effect of the load history (Warm Pre-stress, WPS). The SMILE project - Structural Margin Improvements in aged embrittled RPV with Load history Effects - aims to give sufficient elements to demonstrate, to model and to validate the beneficial WPS effect. It also aims to harmonize the different approaches in the national codes and standards regarding the inclusion of the WPS effect in a RPV structural integrity assessment. The project includes significant experimental work on WPS type experiments with C(T) specimens and a PTS type transient experiment on a large component. This paper deals with the results of the PTS type transient experiment on a component-like, specimen subjected to WPS-loading, the so called Validation Test, carried out within the framework of work package WP4. The test specimen consists of a cylindrical thickwalled specimen with a thickness of 40 mm and an outer diameter of 160 mm, provided with an internal fully circumferential crack with a depth of about 15 mm. The specified load path type is Load-Cool-Unload-Fracture (LCUF). (orig.)

  20. Elastic-plastic analysis of fracture mechanics test specimens. Part 2

    International Nuclear Information System (INIS)

    Talja, H.; Wallin, K.

    1984-12-01

    This is second part of the report of the research program 'Comparisons between computational and experimental elastic-plastic results' started at the Technical Research Centre of Finland in 1981. The first part of the research program was reported earlier and contained a two dimensional linear elastic finite element analysis of four specimen geometries (CT, RCT, ASTM-3P and Charpy-V) and testing and elastic-plastic analysis of the specimen (EGF71; 1TCT, material A 542). In this report the second part of the program containing the testing and 2-D elastic-plastic analyses of five specimens is described. The four specimen geometries mentioned above and two different materials (stainless steel AISI 304 and ferrite pressure vessel steel A533B) are considered. The following comparisons are presented in the report: load vs. load displacement curves, J-integral, crack opening displacement (COD), J vs. COD and the size of the plastic zone. The agreement between the computational and experimental results is quite good. Complete agreement can be achieved only with 3-dimensional calculation models. (author)

  1. Standard practice for preparation and use of Bent-Beam stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for designing, preparing, and using bent-beam stress-corrosion specimens. 1.2 Different specimen configurations are given for use with different product forms, such as sheet or plate. This practice applicable to specimens of any metal that are stressed to levels less than the elastic limit of the material, and therefore, the applied stress can be accurately calculated or measured (see Note 1). Stress calculations by this practice are not applicable to plastically stressed specimens. Note 1—It is the nature of these practices that only the applied stress can be calculated. Since stress-corrosion cracking is a function of the total stress, for critical applications and proper interpretation of results, the residual stress (before applying external stress) or the total elastic stress (after applying external stress) should be determined by appropriate nondestructive methods, such as X-ray diffraction (1). 1.3 Test procedures are given for stress-corrosion testing by ex...

  2. Study of Mechanical Characterization of Ceramic Specimens from a Brazilian Test Adaptation

    Directory of Open Access Journals (Sweden)

    Iglesias, I.

    2011-09-01

    Full Text Available The Brazilian Test is easy to perform and its result is the tensile strength of the material provided certain ratios are fulfilled between the diameter of the sample, the load bearing width and the characteristic length of the material. In this paper we present experimental results obtained from 8 mm-thick ceramic cylinders whose diameter was 40 mm in length. The cylinders were obtained from a standard type of clay by pressing and subsequent baking at 900 ºC. We made a complete mechanical characterization of the material, which included obtaining fracture properties, and a numerical simulation of the Brazilian test based on the cohesive crack model. Numerical results confirm that the size and boundary conditions chosen for the test are adequate to get the actual tensile strength of construction ceramics, which prove that this type of test is useful to compare the strength of several types of construction ceramics in a simple and convenient way. Besides, it requires a very small amount of material to prepare the specimen

    El ensayo de compresión diametral (ensayo Brasileño es un ensayo fácil de realizar que da como resultado la resistencia a tracción del material siempre que se cumplan una serie de proporciones entre el diámetro de la probeta, el ancho de reparto de la carga y la longitud característica del material. En este artículo presentamos unos resultados sobre probetas cerámicas cilíndricas de 40 mm de diámetro y 8 mm de espesor, elaboradas por prensado a partir de arcillas comunes y cocidas a 900 ºC. Se ha realizado una caracterización mecánica de dichas probetas, que incluye sus propiedades en fractura, y una simulación numérica del ensayo brasileño basada en el modelo de fisura cohesiva. Los resultados numéricos confirman que el tamaño y condiciones de contorno elegidos para el ensayo son apropiados para obtener la resistencia a tracción de este tipo de material cerámico con lo que este ensayo se convierte en

  3. Quantitative sensing of corroded steel rebar embedded in cement mortar specimens using ultrasonic testing

    Science.gov (United States)

    Owusu Twumasi, Jones; Le, Viet; Tang, Qixiang; Yu, Tzuyang

    2016-04-01

    Corrosion of steel reinforcing bars (rebars) is the primary cause for the deterioration of reinforced concrete structures. Traditional corrosion monitoring methods such as half-cell potential and linear polarization resistance can only detect the presence of corrosion but cannot quantify it. This study presents an experimental investigation of quantifying degree of corrosion of steel rebar inside cement mortar specimens using ultrasonic testing (UT). A UT device with two 54 kHz transducers was used to measure ultrasonic pulse velocity (UPV) of cement mortar, uncorroded and corroded reinforced cement mortar specimens, utilizing the direct transmission method. The results obtained from the study show that UPV decreases linearly with increase in degree of corrosion and corrosion-induced cracks (surface cracks). With respect to quantifying the degree of corrosion, a model was developed by simultaneously fitting UPV and surface crack width measurements to a two-parameter linear model. The proposed model can be used for predicting the degree of corrosion of steel rebar embedded in cement mortar under similar conditions used in this study up to 3.03%. Furthermore, the modeling approach can be applied to corroded reinforced concrete specimens with additional modification. The findings from this study show that UT has the potential of quantifying the degree of corrosion inside reinforced cement mortar specimens.

  4. Standard Practice for Recording Data from Atmospheric Corrosion Tests of Metallic-Coated Steel Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers a procedure for recording data of atmospheric corrosion tests of metallic-coated steel specimens. Its objective is the assurance of (1) complete identification of materials before testing, (2) objective reporting of material appearance during visual inspections, and (3) adequate photographic, micrographic, and chemical laboratory examinations at specific stages of deterioration, and at the end of the tests. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Computer-aided, single-specimen controlled bending test for fracture-kinetics measurement in ceramics

    International Nuclear Information System (INIS)

    Borovik, V.G.; Chushko, V.M.; Kovalev, S.P.

    1995-01-01

    Fracture testing of ceramics by using controlled crack growth is proposed to allow study of crack-kinetics behavior under a given loading history. A computer-aided, real-time data acquisition system improves the quality of crack-growth parameters obtained in a simple, single-specimen bend test. Several ceramic materials were tested in the present study: aluminum nitride as a linear-elastic material; and alumina and yttria-stabilized zirconia, both representative of ceramics with microstructure-dependent nonlinear fracture properties. Ambiguities in the crack-growth diagrams are discussed to show the importance of accounting for crack-growth history in correctly describing nonequilibrium fracture behavior

  6. Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

    Science.gov (United States)

    Mason, Brian H.; Sleight, David W.; Grenoble, Ray

    2015-01-01

    The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

  7. Comparison between instrumented precracked Charpy and compact specimen tests of carbon steels

    International Nuclear Information System (INIS)

    Nanstad, R.K.

    1980-01-01

    The General Atomic Company High Temperature Gas-Cooled Reactor (HTGR) is housed within a prestressed concrete reactor vessel (PCRV). Various carbon steel structural members serve as closures at penetrations in the vessel. A program of testing and evaluation is underway to determine the need for reference fracture toughness (K/sub IR/) and indexing procedures for these materials as described in Appendix G to Section III, ASME Code for light water reactor steels. The materials of interest are carbon steel forgings (SA508, Class 1) and plates (SA537, Classes 1 and 2) as well as weldments of these steels. The fracture toughness behavior is characterized with instrumented precracked Charpy V-votch specimens (PCVN) - slow-bend and dynamic - and compact specimens (10-mm and 25-mm thicknesses) using both linear elastic (ASTM E399) and elastic-plastic (equivalent Energy and J-Integral) analytical procedures. For the dynamic PCVN tests, force-time traces are analyzed according to the procedures of the Pressure Vessel Research Council (PVRC)/Metal Properties Council (MPC). Testing and analytical procedures are discussed and PCVN results are compared to those obtained with compact specimens

  8. Strength Prediction and Failure Modes of Concrete Specimens Subjected to the Split Test

    DEFF Research Database (Denmark)

    Hoang, Linh Cao; Andersen, M.E.; Hansen, N.T.

    2014-01-01

    This paper deals with modelling and test of concrete specimens subjected to the Brazilian split test. Based on the fictitious crack concept, a simple model for the crack propagation process in the splitting plane is developed. From the model, it is possible to determine the distribution of residual...... tensile strength as crack propagation take place. The residual tensile strength is thereafter used in a rigid plastic analysis of the splitting failure. Based on this combined approach, the ultimate load may either be governed by crack propagation or by a plastic failure, which then terminates the crack...

  9. Service-cycle component-feature specimen TMF testing of steam turbine rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Radosavljevic, M.; Holdsworth, S.R. [Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland); Mazza, E. [Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland); Eidgenoessische Technische Hochschule (ETH), Zurich (Switzerland); Grossmann, P.; Ripamonti, L. [ALSTOM Power (Switzerland) Ltd., Baden (Switzerland)

    2010-07-01

    This paper reviews the methodology adopted in a Swiss Research Collaboration to devise a component-feature representative specimen geometry and the TMF cycle parameters necessary to closely simulate arduous steam turbine operating duty. Implementation of these service-like experimental conditions provides a practical indication of the effectiveness of deformation and crack initiation endurance predictions. Comprehensive post test inspection provides evidence to demonstrate the physical realism of the laboratory simulations in terms of the creep-fatigue damage generated during the benchmark tests. Mechanical response results and physical damage observations are presented and their practical implications discussed for the example of a 2%CrMoNiWV rotor service cycle. (orig.)

  10. Apparatus and method for fatigue testing of a material specimen in a high-pressure fluid environment

    Science.gov (United States)

    Wang, Jy-An; Feng, Zhili; Anovitz, Lawrence M; Liu, Kenneth C

    2013-06-04

    The invention provides fatigue testing of a material specimen while the specimen is disposed in a high pressure fluid environment. A specimen is placed between receivers in an end cap of a vessel and a piston that is moveable within the vessel. Pressurized fluid is provided to compression and tension chambers defined between the piston and the vessel. When the pressure in the compression chamber is greater than the pressure in the tension chamber, the specimen is subjected to a compression force. When the pressure in the tension chamber is greater than the pressure in the compression chamber, the specimen is subjected to a tension force. While the specimen is subjected to either force, it is also surrounded by the pressurized fluid in the tension chamber. In some examples, the specimen is surrounded by hydrogen.

  11. Studies performed on neutron-irradiated copper-doped iron specimens by means of neutron small-angle scattering

    International Nuclear Information System (INIS)

    Naraghi, M.

    1978-01-01

    By means of neutron small-angle scattering precipitation arising from heat-treatment and reactor irradiation in copper-alloyed iron specimens were studied. Copper content varried between 0 and 1.5%, irradiation temperature between 310 and 563K. The specimens had been cooled from the melt partly fast, partly slowely. By taking account of magnetic scattering and by investigating the azimuthal dependence of the total scattering it became possible to distinguish between copper precipitations and vacancy agglomerates. The most obvious effect in the slowly cooled specimens after irradiation with 2-10 19 fast neutrons per cm 2 at a temperature of 563 K is the existence of copper agglomerates with diameters of the order of magnitude of 5nm. Precipitation already occurs to a much lesser extent by the influence of temperature alone. Fast cooling from the melt or low irradiation temperature reduce precipitation during reactor irradiation. Moreover, there are indications on the formation of vacancy accumulations and dislocation rings, the latter especially in the fast cooled specimens. (orig.) [de

  12. Development of resistance welding process. 4. Preparation of pressuring enclosed creep test specimen of 7A material

    International Nuclear Information System (INIS)

    Endo, Hideo; Seki, Masayuki; Ishibashi, Fujio; Hirako, Kazuhito; Tsukada, Tatsuya

    2001-02-01

    Mechanical strength in the position welded by resistance welding system was examined in 1999. The test specimens were destroyed in the welding position in a shorter time than expected in the creep test. Therefore, test specimens were prepared to evaluate the cause of destruction. Inner-pressure enclosed creep test specimens were prepared by resistance welding method. Cladding material with low deviation of thickness and high re-crystallization rate was used. Heat treatment after resistance welding was performed to remove the influence of residual stress and the precipitation of carbides. (1) Before preparation of specimens, the welding condition was fixed. Three test specimens were prepared. Two specimens without heat treatment were transported to MMS in Oarai Engineering Center on Aug. 4, 2000. One specimen with heat treatment was transported to MMS after evaluating the residual stress to get optimum heat treatment condition. (2) Specimens were prepared with welding end plugs to both ends of ferritic ODS cladding. Enclosing sides were welded with highly strong Ferritic/Martensitic steel end plugs. The other sides were welded with ferritic ODS end plugs. (3) Some kinds of electrical wave data were obtained during performing welding. Welding position was evaluated with supersonic detector after performing welding. (4) Mechanical strength of welding position in high temperature 800degC was confirmed to be equal to or larger than that of cladding material. The highly qualified specimens in the present were successfully prepared. (author)

  13. Testing of Small Graphite Samples for Nuclear Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Julie Chapman

    2010-11-01

    Accurately determining the mechanical properties of small irradiated samples is crucial to predicting the behavior of the overal irradiated graphite components within a Very High Temperature Reactor. The sample size allowed in a material test reactor, however, is limited, and this poses some difficulties with respect to mechanical testing. In the case of graphite with a larger grain size, a small sample may exhibit characteristics not representative of the bulk material, leading to inaccuracies in the data. A study to determine a potential size effect on the tensile strength was pursued under the Next Generation Nuclear Plant program. It focuses first on optimizing the tensile testing procedure identified in the American Society for Testing and Materials (ASTM) Standard C 781-08. Once the testing procedure was verified, a size effect was assessed by gradually reducing the diameter of the specimens. By monitoring the material response, a size effect was successfully identified.

  14. Development of European creep crack growth testing code of practice for industrial specimens

    International Nuclear Information System (INIS)

    Dogan, B.; Nikbin, K.; Petrovski, B.

    2004-01-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elastic creep, elastic compliance measurements

  15. COMPARISON BETWEEN WOOD DRYING DEFECT SCORES: SPECIMEN TESTING X ANALYSIS OF KILN-DRIED BOARDS

    OpenAIRE

    Djeison Cesar Batista; Márcio Pereira da Rocha; Ricardo Jorge Klitzke

    2015-01-01

    It is important to develop drying technologies for Eucalyptus grandis lumber, which is one of the most planted species of this genus in Brazil and plays an important role as raw material for the wood industry. The general aim of this work was to assess the conventional kiln drying of juvenile wood of three clones of Eucalyptus grandis. The specific aims were to compare the behavior between: i) drying defects indicated by tests with wood specimens and conventional kiln-dried boards; and ii) ph...

  16. Measurement of tensile and fracture toughness properties using small punch test

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah Priti Kotak

    2005-05-01

    Small punch test wu carried out at room temperature on five different steels using 10 mm by 10 mm specimens of 0.4 mm thickness in a univesal testing machine. The tensile and fracture toughness properties of the five steels obtained from small punch test were compared with those obtained from the standard test method. The results (except in one steel) show that the tensile properties obtained from small punch test are in close proximity to those obtained ftom uni-axial tension test. The results also show that fracture toughness (Jic) properties obtained ftom small punch test are within ±20% of the corresponding values obtained using standard test procedures. (author)

  17. Asphalt Mixture Fatigue Testing : Influence of Test Type and Specimen Size

    NARCIS (Netherlands)

    Li, N.

    2013-01-01

    Fatigue characterization of an asphalt mixture is commonly estimated by laboratory fatigue tests. Based on the classical fatigue analysis, fatigue lives obtained from different test devices are not comparable even when they are performed at the same test conditions. It is believed that there are two

  18. NIF small optics laser damage test specifications

    International Nuclear Information System (INIS)

    Sheehan, L

    1999-01-01

    The Laser Damage Group is currently conducting tests on small optics samples supplied for initial evaluation of potential NIF suppliers. This document is meant to define the specification of laser-induced damage for small optics and the test methods used to collect the data. A rating system which will be applied for vendor selection is presented

  19. Development of an evaluation method for fracture mechanical tests on small samples based on a cohesive zone model

    International Nuclear Information System (INIS)

    Mahler, Michael

    2016-01-01

    The safety and reliability of nuclear power plants of the fourth generation is an important issue. It is based on a reliable interpretation of the components for which, among other fracture mechanical material properties are required. The existing irradiation in the power plants significantly affects the material properties which therefore need to be determined on irradiated material. Often only small amounts of irradiated material are available for characterization. In that case it is not possible to manufacture sufficiently large specimens, which are necessary for fracture mechanical testing in agreement with the standard. Small specimens must be used. From this follows the idea of this study, in which the fracture toughness can be predicted with the developed method based on tests of small specimens. For this purpose, the fracture process including the crack growth is described with a continuum mechanical approach using the finite element method and the cohesive zone model. The experiments on small specimens are used for parameter identification of the cohesive zone model. The two parameters of the cohesive zone model are determined by tensile tests on notched specimens (cohesive stress) and by parameter fitting to the fracture behavior of smalls specimens (cohesive energy). To account the different triaxialities of the specimens, the cohesive stress is used depending on the triaxiality. After parameter identification a large specimen can be simulated with the cohesive zone parameters derived from small specimens. The predicted fracture toughness of this big specimen fulfills the size requirements in the standard (ASTM E1820 or ASTM E399) in contrast to the small specimen. This method can be used for ductile and brittle material behavior and was validated in this work. In summary, this method offers the possibility to determine the fracture toughness indirectly based on small specimen testing. Main advantage is the low required specimen volume. Thereby massively

  20. Redesigning axial-axial (biaxial) cruciform specimens for very high cycle fatigue ultrasonic testing machines.

    Science.gov (United States)

    Montalvão, Diogo; Wren, Andrew

    2017-11-01

    The necessity to increase performances in terms of lifetime and security in mechanical components or structures is the motivation for intense research in fatigue. Applications range from aeronautics to medical devices. With the development of new materials, there is no longer a fatigue limit in the classical sense, where it was accepted that the fatigue limit is the stress level such that there is no fracture up to 1E7 cycles. The recent development of ultrasonic testing machines where frequencies can go as high as 20 kHz or over enabled tests to be extended to ranges larger than 1E9 in just a few days. This area of studies is now known as Very High Cycle Fatigue (VHCF). On the other hand, most of the existing test equipment in the market for both classical and VHCF are uniaxial test machines. However, critical components used in Engineering applications are usually subjected to complex multi-axial loading conditions. In this paper, it is presented the methodology to redesigning existing cruciform test specimens that can be used to create an in-plane biaxial state of stress when used in 'uniaxial' VHCF ultrasonic testing machines (in this case, the term 'uniaxial' is used not because of the state of stress created at the centre of the specimen, but because of the direction at which the load is applied). The methodology is explained in such a way that it can be expanded to other existing designs, namely cruciform designs, that are not yet used in VHCF. Also, although the approach is presented in simple and logical terms, it may not be that obvious for those who have a more focused approach on fatigue rather than on modal analysis. It is expected that by contributing to bridging the gap between the sciences of modal analysis and fatigue, this research will help and encourage others exploiting new capabilities in VHCF.

  1. Evaluation of fracture toughness of vessel materials using small-size specimens and full stress-strain curves

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, A A; Chausov, N G [Akademyiya Nauk Ukrayini, Kiev (Ukraine)

    1994-12-31

    Physically substantiated dependences between crack resistance characteristics determined by the parameters of descending sections of full stress-strain curves and stressed state rigidity at crack initiation moment, have been experimentally obtained. The possibility of crack resistance reliable estimation based on full stress-strain obtained using small-size specimens with different concentrators, has thus been experimentally substantiated. Results obtained by the method and actual temperature dependence of irradiated steel 15X2NMFA crack resistance characteristics, agreed well. 2 refs., 7 figs.

  2. Relation between small airways disease and parenchymal destruction in surgical lung specimens.

    Science.gov (United States)

    Willems, L N; Kramps, J A; Stijnen, T; Sterk, P J; Weening, J J; Dijkman, J H

    1990-01-01

    The relation between small airways disease and parenchymal destruction was investigated in lungs and lobes removed at surgery from 27 patients aged 15-70 years. Eight of the 27 patients were life-long non-smokers. The degree of small airways disease was assessed by semi-quantitative grading (SAD score) and by measuring diameter and wall thickness of membranous bronchioles. Parenchymal destruction was measured in three ways. Firstly, the number of alveolar attachments on membranous bronchioles per millimetre of circumference (AA/mm) was counted; the number of broken attachments was subtracted from the total AA/mm to give the numbers of intact attachments (normal AA/mm). Secondly, a point counting technique was used to give a destructive index (DI). Thirdly, the mean linear intercept (Lm) was determined. Total and normal AA/mm correlated negatively with the SAD score of membranous bronchioles (rs = -0.48 and -0.51) and with wall thickness (rs = -0.37 and -0.45) and DI correlated with wall thickness (rs = 0.5) and with the SAD score of respiratory bronchioles (rs = 0.53). Lm did not correlate with indices of small airway disease and total and normal AA/mm did not correlate with diameter. Multiple regression analyses showed that the correlation of total AA/mm with the SAD score of membranous and respiratory bronchioles and with wall thickness were not confounded by age or smoking. It is concluded that small airways disease is related to destruction of peribronchiolar alveoli, and it is postulated that small airways disease has a direct role in the causation of centrilobular emphysema. PMID:2315880

  3. Performance of next-generation sequencing on small tumor specimens and/or low tumor content samples using a commercially available platform.

    Directory of Open Access Journals (Sweden)

    Scott Morris

    Full Text Available Next generation sequencing tests (NGS are usually performed on relatively small core biopsy or fine needle aspiration (FNA samples. Data is limited on what amount of tumor by volume or minimum number of FNA passes are needed to yield sufficient material for running NGS. We sought to identify the amount of tumor for running the PCDx NGS platform.2,723 consecutive tumor tissues of all cancer types were queried and reviewed for inclusion. Information on tumor volume, success of performing NGS, and results of NGS were compiled. Assessment of sequence analysis, mutation calling and sensitivity, quality control, drug associations, and data aggregation and analysis were performed.6.4% of samples were rejected from all testing due to insufficient tumor quantity. The number of genes with insufficient sensitivity make definitive mutation calls increased as the percentage of tumor decreased, reaching statistical significance below 5% tumor content. The number of drug associations also decreased with a lower percentage of tumor, but this difference only became significant between 1-3%. The number of drug associations did decrease with smaller tissue size as expected. Neither specimen size or percentage of tumor affected the ability to pass mRNA quality control. A tumor area of 10 mm2 provides a good margin of error for specimens to yield adequate drug association results.Specimen suitability remains a major obstacle to clinical NGS testing. We determined that PCR-based library creation methods allow the use of smaller specimens, and those with a lower percentage of tumor cells to be run on the PCDx NGS platform.

  4. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D' Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam, E-mail: jacojulio@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita [Centro Tecnológico do Exercito (CETEx), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the {sup 18}F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  5. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D'Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam; Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita

    2017-01-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18 F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  6. Quantification of Applied Stresses of C-Ring Specimens for Stress Corrosion Cracking Tests

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Kim, Sun Jae; Rhee, Chang Kyu; Kuk, Il Hiun; Choi, Jong Ho

    1997-01-01

    For comparing their resistances for stress-corrosion cracking(SCC) in the K600-MA, K690-MA, and K600-TT tubes, C-ring specimens were fabricated with the various thermal-treatments to control the distributions of the precipitates like Cr-carbides. The bending stresses were analyzed to determine the amounts to make the stress quantitatively to all the C-ring samples, and then the stresses were calculated with the relation to the outer diameter(O.D) deflection(δ) of the C-rings. To measure accurately the bending strains of the C-ring specimens, the strain gauges were used and the compression test was also carried out. In the elastic region, the stresses in both the transverse and the circumferential directions were different with the locations of the strain gauges as attached at α= 30 .deg., 45 .deg., and 90 .deg. to the principal stress direction, but those in the longitudinal direction were independent of their attached locations. Calculated stresses from the strains obtained using the strain gauges were well agreed with the theoretical. In the plastic region over δ=1.0mm, the stresses for the TT tubes showed lower values of about 400MPa than those for the MA tubes. However, the stresses among the TT tubes showed almost the similar values in this region. Therefore, the states of the stresses applied to the C-ring specimens would be different with the material conditions, i.e, the chemical compositions, the thermal treatments such as MA and TT

  7. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2014-12-01

    Full Text Available In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞ and the ternary blended cement mixture had the lowest reaction factor (r. Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  8. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    Science.gov (United States)

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  9. Development of the plant life management technology for RPV steels [ - Current status of surveillance test specimen reconstitution program -

    International Nuclear Information System (INIS)

    Kazunobu, Sakamoto; Eliichiro, Otsuka; Yoshiaki, Oka; Kosei, Taguchi; Michiyoshi, Yamamoto

    2001-01-01

    In order to develop the reconstitution technology to standardize surveillance test specimen reconstitution practices to deal with the extended service life of reactor pressure vessels, the Japan Power Engineering and Inspection Corporation (JAPEIC) has been carried out the project entrusted by the Ministry of International Trade and Industry (MITI). We focus on a correlation between the reduction of absorbed energy and the interaction of the heat affected zone (HAZ) and the plastic zone, to establish applicable reconstitution conditions for Charpy specimens. The relationship between the plastic zone width and the absorbed energy has been obtained by estimating the plastic zone width from the hardness distribution of the Charpy specimens. Impact tests of reconstituted specimens with 10 mm-length insert using the surface activated joining method were performed and the test results were compared to those obtained by the standard specimens. By comparing the length of insert material to the sum of HAZ width and plastic zone width, it is clear that the interaction causes the reduction of the absorbed energy. Hence, the applicable conditions of reconstituted Charpy specimens could be assessed by comparing the insert length to the sum of HAZ width and plastic zone width. Moreover the effects of the possible deviations from the standard shape and size specimens for the reconstituted specimens were studied. (authors)

  10. Do small fish mean no voucher? Using a flatbed desktop scanner to document larval and small specimens before destructive analyses

    Czech Academy of Sciences Publication Activity Database

    Kalous, L.; Šlechtová, Věra; Petrtýl, M.; Kohout, Jan; Čech, Martin

    2010-01-01

    Roč. 26, č. 4 (2010), s. 614-617 ISSN 0175-8659 R&D Projects: GA ČR GA206/06/1371; GA ČR GP206/09/P266 Institutional research plan: CEZ:AV0Z50450515; CEZ:AV0Z60170517 Keywords : small fish * voucher * desktop scanner Subject RIV: GL - Fishing Impact factor: 0.945, year: 2010

  11. Development of European creep crack growth testing code of practice for industrial specimens

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, B.; Nikbin, K. [Imperial College, London (United Kingdom); Petrovski, B. [Technische Univ. Darmstadt (DE). Inst. fuer Werkstoffkunde (IFW)

    2004-07-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elasticcreep, elastic compliance measurements.

  12. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  13. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    Science.gov (United States)

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  14. TEST FUSION IN ADULT FORAMINIFERA: A REVIEW WITH NEW OBSERVATIONS OF AN EARLY EOCENE NUMMULITES SPECIMEN

    Science.gov (United States)

    Ferràndez-Cañadell, Carles; Briguglio, Antonino; Hohenegger, Johann; Wöger, Julia

    2015-01-01

    In foraminifera, so-called “double tests” usually arise due to abnormal growth originating mainly from twinning, but may also be caused by irregularities in the early chambers and by regeneration after test injury that modifies the direction of growth. A fourth cause of double tests has only rarely been reported: the fusion of the tests of two adult individuals. We studied an early Eocene Nummulites double test consisting of two adult individuals that fused after an extended period of independent growth. The specimen was studied using computed tomography with micrometric resolution (micro-CT) that allowed bi- and three-dimensional visualization of the internal structure. Before fusion each individual test had 30–36 chambers, which, by comparison with growth rates in recent nummulitids, implies at least three months of independent growth. After fusion, the compound test grew in two spirals that fused after about one whorl and then continued in a single spiral. To fuse their tests, either adult individuals have to be forced to do so or the allorecognition (ability to distinguish between self and another individual) mechanisms must fail. A possible explanation for the merged Nummulites tests in this study is forced fusion in attached individuals after surviving ingestion and digestion by a metazoan. Alternatively, environmental stress could lead to a failure of allorecognition mechanisms and/or foraminiferal motility. Once fused, subsequent growth seems to be determined mainly by the relative orientation of individual tests. In any case, the frequency in which adult fusion occurs remains unknown. PMID:26166916

  15. Small Optics Laser Damage Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, Justin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-19

    This specification defines the requirements and procedure for laser damage testing of coatings and bare surfaces designated for small optics in the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL).

  16. Material Models to Study the Bauschinger Effect on an Aluminum Shear Test Specimen

    International Nuclear Information System (INIS)

    Cardoso, Rui P. R.; Gracio, Jose J.; Yoon, Jeong-Whan

    2007-01-01

    Sheet metal forming processes generally involve complex loadings and nonlinear material models. Combinations of drawing, re-drawing and/or reverse drawing operations commonly induce cyclic loads with non-proportional strain paths, leading to Bauschinger effects that can not be predicted by conventional isotropic hardening laws. In order to properly represent this effect, it is also required to accommodate an appropriate kinematic hardening model along with an anisotropic yield function. In this work, two different approaches will be used to predict the Bauschinger effect for an Aluminum shear test specimen: the rate dependent crystal plasticity model and a new combined isotropic/kinematic hardening model based on the two yield surfaces approach (loading and boundary yield surfaces), as recently proposed

  17. Fracture toughness evaluation using circumferential notched tensile specimens by the tensile test and ANSYS software

    Energy Technology Data Exchange (ETDEWEB)

    Meydanlik, N. [Mechanical Engineering Department, Trakya University, Edirne (Turkey)

    2013-07-01

    Fracture toughness (K{sub Ic} ) is the most important parameter that defines mechanical behaviour of the materials using machine design. Since, fracture tests are both difficult and time consuming, the researchers have been investigating for the easier evaluation of K{sub Ic} for many years. In this work; K{sub Ic} values have been obtained by using ANSYS software based on the experimental values evaluated in the previous studies. It was shown that there is no significant difference between the experimental ones and the ones obtained by ANSYS. This procedure can provide an important advantage on obtaining of the K{sub IC} values. Key words: Fracture toughness (K{sub Ic} ), circumferential notched tensile specimens, ANSYS.

  18. Design of creep machine and creep specimen chamber for carrying out creep tests in flowing liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@igcar.gov.in; Laha, K.; Sakthy, S.; Mathew, M.D.; Jayakumar, T.

    2014-02-15

    Highlights: • Design of a lever type creep machine for carrying out creep test in flowing sodium. • Leveling of lever during creep was achieved by automated movement of fulcrum. • Design of creep chamber for providing constant sodium flow rate across creep specimen. • Minimum use of bellow in chamber for sodium containment and mechanical isolation. • Mini-lever mechanism to counter balance load reduction on specimen due to bellow stiffness. - Abstract: A creep testing system has been designed, fabricated, installed and validated for carrying out creep tests in flowing liquid sodium. The testing system consists of two sections namely creep testing machine and an environmental chamber. The testing system has the ability of (i) applying tensile load to the test specimen through a lever, (ii) monitoring continuously the creep elongation and (iii) allowing sodium to flow around the creep specimen at constant velocity. The annular space between the creep specimen and the environmental chamber has been suitably designed to maintain constant sodium flow velocity. Primary and secondary bellows are employed in the environmental chamber to (i) mechanically isolate the creep specimen, (ii) prevent the flowing sodium in contact with air and (iii) maintain an argon gas cover to the leaking sodium if any from primary bellow, with a provision to an alarm get activated by a spark plug. The lever-horizontality during creep test has been maintained by automatically lifting up the fulcrum instead of lowering down the pull rod as conventionally used. A mini lever mechanism has been incorporated in the load train to counter balance the load reduction on specimen from the changing stiffness of the bellows. The validation of the testing system has been established by carrying out creep tests on 316L(N) stainless steel at 873 K over a wide stress range and comparing the results with those obtained in air by employing the developed and conventional creep testing machines.

  19. USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2010-06-01

    Full Text Available Regarding a new regulation from Indonesia FDA (Badan POM-RI, all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm, with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990. Precision of the method was very good with coefficient of variance (CV 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.   Keywords: Rifampicin, Validation, USFDA-Guideline

  20. Creep-fatigue assessment of a thermina test specimen using the R5 procedure

    International Nuclear Information System (INIS)

    Booth, P.; Budden, P.J.; Bate, S.K.

    1997-01-01

    A creep-fatigue life assessment of an axisymmetric 316 stainless steel test specimen under constant mechanical and cyclic thermal shock loading using the R5 Procedure is described in this paper. This test was carried out at CEA, France, and formed part of the 'Thermina' series. Stress analysis has been carried out using both full inelastic finite element analysis and also the simplified shakedown methods, based on elastic calculation, within R5. The estimates of strain range and the stress at the start of the creep dwell have then been used with R5 to estimate creep and fatigue damage per cycle and hence to make predictions of component life. The predicted lives are compared with the lives observed in the tests. The simplified R5 estimate of life, based on development of a crack of depth 200 microns, is 260 cycles using best-estimate material properties. Experimentally, cracks of depth at least 150 microns were observed in between 526 and 650 cycles, for two similar tests. The simplified R5 route therefore leads to an estimate of life which is conservative but not unduly so on this component. Detailed cyclic inelastic analysis using the ORNL constitutive model and the ABAQUS finite element code to estimate the strain range and dwell stress led to a best estimate of 618 cycles to crack initiation using R5. (author). 16 refs, 11 figs, 4 tabs

  1. Examination of cadmium safety rod thermal test specimens and failure mechanism evaluation

    International Nuclear Information System (INIS)

    Thomas, J.K.; Peacock, H.B.; Iyer, N.C.

    1992-01-01

    The reactor safety rods may be subjected to high temperatures due to gamma heating after the core coolant level has dropped during the ECS phase of a hypothetical LOCA event. Accordingly, an experimental cadmium safety rod testing subtask was established as part of a task to address the response of reactor core components to this accident. Companion reports describe the experiments and a structural evaluation (finite element analysis) of the safety rod. This report deals primarily with the examination of the test specimens, evaluation of possible failure mechanisms, and confirmatory separate effects experiments. It is concluded that the failures observed in the cadmium safety rod thermal tests which occurred at low temperature (T 800 degrees C) with fast thermal ramp rates are concluded to be mechanical in nature without significant environmental degradation. Based on these tests, tasks were initiated to design and manufacture B 4 C safety rods to replace the cadmium safety rods. The B 4 C safety rods have been manufactured at this time and it is currently planned to charge them to the reactor in the near future. 60 refs

  2. Benign endometrial proliferations mimicking malignancies: a review of problematic entities in small biopsy specimens.

    Science.gov (United States)

    Ip, Philip Pun-Ching

    2018-02-14

    Benign proliferations that mimic malignancies are commonly encountered during the course of assessment of small and fragmented endometrial samples. Although benign, endometrial epithelial metaplasias often coexist with premalignant or malignant lesions causing diagnostic confusion. The difficulty with mucinous metaplasia lies in its distinction from atypical mucinous glandular proliferations and mucinous carcinomas, which are associated with significant interobserver variability. Papillary proliferation of the endometrium is commonly associated with hormonal drugs and endometrial polyps and is characterised by papillae with fibrovascular cores covered by epithelial cells without cytologic atypia. They are classified into simple or complex papillary proliferations depending on the architectural complexity and extent of proliferation. Complex papillary proliferations are associated with a high risk of concurrent or subsequent hyperplasia with atypia/carcinoma. Papillary proliferations may have coexisting epithelial metaplasias and, most commonly, mucinous metaplasia and syncytial papillary change. Those with striking mucinous metaplasia overlap morphologically with papillary mucinous metaplasia. The latter has been proposed as a precursor of endometrial mucinous carcinoma. Misinterpreting the Arias-Stella reaction as a malignant or premalignant lesion is more likely to occur if the pathologist is unaware that the patient is pregnant or on hormonal drugs. Endometrial hyperplasia with secretory changes may occasionally be difficult to distinguish from the torturous and crowded glands of a late secretory endometrium. Endometrial polyps may have abnormal features that can be misinterpreted as endometrial hyperplasia or Mullerian adenosarcoma. Awareness of these benign endometrial proliferations and their common association with hormonal medication or altered endogenous hormonal levels will help prevent the over-diagnosis of premalignant and malignant lesions.

  3. Study on Identification of Material Model Parameters from Compact Tension Test on Concrete Specimens

    Science.gov (United States)

    Hokes, Filip; Kral, Petr; Husek, Martin; Kala, Jiri

    2017-10-01

    Identification of a concrete material model parameters using optimization is based on a calculation of a difference between experimentally measured and numerically obtained data. Measure of the difference can be formulated via root mean squared error that is often used for determination of accuracy of a mathematical model in the field of meteorology or demography. The quality of the identified parameters is, however, determined not only by right choice of an objective function but also by the source experimental data. One of the possible way is to use load-displacement curves from three-point bending tests that were performed on concrete specimens. This option shows the significance of modulus of elasticity, tensile strength and specific fracture energy. Another possible option is to use experimental data from compact tension test. It is clear that the response in the second type of test is also dependent on the above mentioned material parameters. The question is whether the parameters identified within three-point bending test and within compact tension test will reach the same values. The presented article brings the numerical study of inverse identification of material model parameters from experimental data measured during compact tension tests. The article also presents utilization of the modified sensitivity analysis that calculates the sensitivity of the material model parameters for different parts of loading curve. The main goal of the article is to describe the process of inverse identification of parameters for plasticity-based material model of concrete and prepare data for future comparison with identified values of the material model parameters from different type of fracture tests.

  4. Characterization of test specimens produced in reduced size for X-ray microtomography (µ-CT tests

    Directory of Open Access Journals (Sweden)

    E. E. BERNARDES

    Full Text Available Abstract The need to use reduced sample sizes, in order to attain improved spatial resolution in (µ-CT tests applied in Portland cement composites, makes researchers perform the fractionation of materials to obtain samples with dimensions compatible with the capacity of the scanning equipment, which might cause alterations in the microstructure under analysis. Therefore, a test specimen (TS with dimensions compatible with the scanning capacity of a microtomography system that operates with an X-ray tube and voltage ranging from 20 to 100 kV was proposed. Axial compression strength tests were made and their total porosity was assessed by an apparent density and solid fraction density ratio, which were obtained by means of mercury and helium pycnometry and µ-CT technique, respectively. The adoption of that TS has shown to be viable for providing a sample with a higher level of representation.

  5. The effect of small specimen volume on the deformation of Zircaloy-4 PWR cladding under mainly convective cooling by steam

    International Nuclear Information System (INIS)

    Oakden, M.M.; Reynolds, A.E.

    1983-01-01

    Creep rupture tests were performed in flowing steam on single rod specimens of 17x17 type PWR Zircaloy-4 cladding 460 mm long. They were tested at temperatures between 640 deg.C and 985 deg.C with internal pressures in the range 1.00-9.65 MPa (gauge) (145-1400 lb/in 2 ). The internal free volume was limited to 2.9 ml. Axially extended 'carrot' shaped deformations were produced, the range of temperatures and pressures over which these occurred was found to be similar to that observed in previous tests conducted with a much larger free volume. The main result of limiting the internal volume was that straining of the specimens was accompanied by a more rapid drop in the internal pressure than occurred previously, and which reduced the extent of the deformation compared with that seen in the earlier work. However, diametral strains in excess of 33% were observed which would result in mechanical interaction of neighbouring bulges if this occurred in a multi-rod array. (author)

  6. Experimental Method for Plotting S-N Curve with a Small Number of Specimens

    Directory of Open Access Journals (Sweden)

    Strzelecki Przemysław

    2016-12-01

    Full Text Available The study presents two approaches to plotting an S-N curve based on the experimental results. The first approach is commonly used by researchers and presented in detail in many studies and standard documents. The model uses a linear regression whose parameters are estimated by using the least squares method. A staircase method is used for an unlimited fatigue life criterion. The second model combines the S-N curve defined as a straight line and the record of random occurrence of the fatigue limit. A maximum likelihood method is used to estimate the S-N curve parameters. Fatigue data for C45+C steel obtained in the torsional bending test were used to compare the estimated S-N curves. For pseudo-random numbers generated by using the Mersenne Twister algorithm, the estimated S-N curve for 10 experimental results plotted by using the second model, estimates the fatigue life in the scatter band of the factor 3. The result gives good approximation, especially regarding the time required to plot the S-N curve.

  7. Lessons learned from nanoscale specimens tested by MEMS-based apparatus

    Science.gov (United States)

    Elhebeary, Mohamed; Saif, M. Taher A.

    2017-06-01

    The last two decades were marked by the innovative synthesis of nanomaterials and devices. The success of these devices hinges on the mechanical properties of nanomaterials and an understanding of their deformation and failure mechanisms. Many novel testing techniques have been developed to test materials at small scale. This paper reviews the state-of-the-art microelectromechanical systems (MEMS) apparatus developed to characterize materials at nanoscale, and the key insights gained on structure-property relations of materials through these characterizations. Finally, new applications of MEMS in testing living materials, such as tissues and cells, for disease diagnosis and prognosis are discussed.

  8. Lessons learned from nanoscale specimens tested by MEMS-based apparatus

    International Nuclear Information System (INIS)

    Elhebeary, Mohamed; Saif, M Taher A

    2017-01-01

    The last two decades were marked by the innovative synthesis of nanomaterials and devices. The success of these devices hinges on the mechanical properties of nanomaterials and an understanding of their deformation and failure mechanisms. Many novel testing techniques have been developed to test materials at small scale. This paper reviews the state-of-the-art microelectromechanical systems (MEMS) apparatus developed to characterize materials at nanoscale, and the key insights gained on structure-property relations of materials through these characterizations. Finally, new applications of MEMS in testing living materials, such as tissues and cells, for disease diagnosis and prognosis are discussed. (topical review)

  9. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Dr. Lev [Univ. of Minnesota, Minneapolis, MN (United States); Salles, Lucio [Univ. of Minnesota, Minneapolis, MN (United States)

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.

  10. Residual stress state in pipe cut ring specimens for fracture toughness testing

    Energy Technology Data Exchange (ETDEWEB)

    Damjanovic, Darko [J.J. Strossmayer Univ. of Osijek, Slavonski Brod (Croatia). Mechanical Engineering Faculty; Kozak, Drazan [Zagreb Univ. (Croatia). Dept. for Mechanical Design; Marsoner, Stefan [Materials Center, Leoben (Austria).; Gubeljak, Nenad [Maribor Univ. (Slovenia). Chair of Mechanics

    2017-07-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  11. Residual stress state in pipe cut ring specimens for fracture toughness testing

    International Nuclear Information System (INIS)

    Damjanovic, Darko; Kozak, Drazan; Marsoner, Stefan; Gubeljak, Nenad

    2017-01-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  12. Linear Array Ultrasonic Testing Of A Thick Concrete Specimens For Non-Destructive Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States); Zammerachi, Mattia [Univ. of Minnesota, Minneapolis, MN (United States); Ezell, N. Dianne Bull [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-04-01

    The University of Minnesota and Oak Ridge National Laboratory are collaborating on the design and construction of a concrete specimen with sufficient reinforcement density and cross-sectional size to represent a light water reactor (LWR) containment wall with various defects. The preliminary analysis of the collected data using extended synthetic aperture focussin technique (SAFT) reconstruction indicated a great potential of the ultrasound array technology for locating relatively shallow distresses. However, the resolution and reliability of the analysis is inversely proportional to the defect depth and the amount of reinforcement between the measurement point and the defect location. The objective of this round of testing is to evaluate repeatability of the obtained reconstructions from measurements with different frequencies as well as to examine the effect of the duration of the sending ultrasound signal on the resulting reconstructions. Two series of testing are performed in this study. The objective of the first series is to evaluate repeatability of the measurements and resulting reconstructed images. The measurements use three center frequencies. Five measurements are performed at each location with and without lifting the device. The analysis of the collected data suggested that a linear array ultrasound system can produce reliably repeatable reconstructions using 50 kHz signals for relatively shallow depths (less than 0.5 m). However, for reconstructions at the greater depths the use of lower frequency and/or signal filtering to reduce the effect of signal noise may be required. The objective of the second series of testing is to obtain measurements with various impulse signal durations. The entire grid on the smooth surface is tested with four different various impulse signal durations. An analysis of the resulting extended SAFT reconstructions suggested that Kirchhoff-based migration leads to easier interpreting reconstructions when shorter duration

  13. Analysis of anisotropic damage in forged Al–Cu–Mg–Si alloy based on creep tests, micrographs of fractured specimen and digital image correlations

    Energy Technology Data Exchange (ETDEWEB)

    Gariboldi, Elisabetta, E-mail: elisabetta.gariboldi@polimi.it [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy); Naumenko, Konstantin, E-mail: konstantin.naumenko@ovgu.de [Otto-von-Guericke-University Magdeburg, Institute of Mechanics, D-39106 Magdeburg (Germany); Ozhoga-Maslovskaja, Oksana, E-mail: oksana.ozhogamaslovskaja@gmail.com [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy); Zappa, Emanuele, E-mail: emanuele.zappa@polimi.it [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy)

    2016-01-15

    The aim of this paper is to analyze anisotropic damage mechanisms in forged Al–Cu–Mg–Si alloy based on the results of creep tests. Smooth specimens are sampled in three forging directions. Creep strain vs. time curves as well as light optical microscope and scanning electron microscope observations illustrate basic features of damage growth. Flat notch specimens are sampled in different directions to analyze stress redistributions and damage in zones of stress concentration. The digital image correlation technique has been applied in situ in order to extract the strain values on the surface of the notched specimens. All observations demonstrate that the principal origins of anisotropic creep and damage are associated with elongated grains and second phase clustered particles located at grain boundaries. Longitudinal specimens possess nucleations of decohesion sites and growth of voids around second phase particles at grain boundaries. Damage evolution for radial and transverse specimens is due to the formation and growth of cracks in second phase particles orthogonal to the principal stress axis. Residual strains are confined to the notch root as well as to the flanges of advanced macrocrack, indicating the small scale yielding during the creep fracture process.

  14. Seismic response and damping tests of small bore LMFBR piping and supports

    International Nuclear Information System (INIS)

    Barta, D.A.; Anderson, M.J.; Severud, L.K.; Lindquist, M.R.

    1984-01-01

    Seismic testing and analysis of a prototypical Liquid Metal Fast Breeder Reactor (LMFBR) small bore piping system is described. Measured responses to simulated seismic excitations are compared with analytical predictions based on NRC Regulatory Guide 1.61 and measured system damping values. The test specimen was representative of a typical LMFBR insulated small bore piping system, and it was supported from a rigid test frame by prototypic dead weight supports, mechanical snubbers and pipe clamps

  15. Fatigue damage observed non-destructively in fibre composite coupon test specimens by X-ray CT

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2016-01-01

    This study presents a method for monitoring the 3D fatigue damage progression on a micro-structural level in a glass fibre/polymer coupon test specimen by means of laboratory X-ray Computed Tomography (CT). A modified mount and holder made for the standard test samples to fit into the X-ray CT...... scanner along with a tension clamp solution is presented. Initially, the same location of the test specimen is inspected by ex-situ X-ray CT during the fatigue loading history, which shows the damage progression on a micro-structural level. The openings of individual uni-directional (UD) fibre fractures...

  16. 49 CFR 40.173 - Who is responsible for paying for the test of a split specimen?

    Science.gov (United States)

    2010-10-01

    ... is responsible for paying for the test of a split specimen? (a) As the employer, you are responsible... 49 Transportation 1 2010-10-01 2010-10-01 false Who is responsible for paying for the test of a.... (b) As the employer, you must not condition your compliance with these requirements on the employee's...

  17. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  18. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2014-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  19. Charpy impact test of oxidized and hydrogenated zircaloy using a thin strip specimen

    International Nuclear Information System (INIS)

    Otsuka, Teppei; Hashizume, Kenichi; Sugisaki, Masayasu

    2004-01-01

    The impact properties of an oxidized and a hydrogenated Zircaloy have been studied with an instrumented Charpy machine by using a strip Charpy V-notch specimen (1 mm thick by 4mm wide). Fracture processes such as crack initiation and propagation were examined using load-displacement curves obtained in this study. In the case of the hydrogenated specimen containing preferentially oriented hydrides, an appreciable decrease in the absorbed energy was observed in the crack propagation rather than in the crack initiation. From results of fractographs of the specimen, it was suggested that the reduction of the crack propagation energy of hydrogenated specimen could be attributed to the change of the stress state in the Zircaloy matrix, which was caused by the fracture of hydride in the inner part of specimen. In the case of the specimen oxidized at 973k for 60 min, on which an oxide layer (4 μm in thickness) and oxygen incursion layer (4μm) were formed, the surface layers affected the crack initiation process. The growing oxygen incursion layer, in particular, resulted in the constraint of plastic deformation of the Zircaloy matrix not only in the crack initiation but also in the crack propagation as its thickness increased. (author)

  20. Technique for the residual life assessment of high temperature components based on creep-rupture testing on welded miniature specimens

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, A.; Guardamagna, C.; Moscotti, L.; Ranzani, L. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-06-01

    Following the present trend in the development of advanced methodologies for residual life assessment of high temperature components operating in power plants, particularly in non destructive methods, a testing technique has been set up at ENEL-CRAM based on creep-rupture testa in an argon on welded miniature specimens. Five experimental systems for creep-rupture tests in an argon atmosphere have been set up which include high accuracy systems, vacuum chambers and exrwnsometer devices. With the aim of establishing and validating the suitability of the experimental methodology, creep-rupture and interrupted creep testing programmes have been performed on miniature specimens (2 mm diameter and 10 mm gauge lenght). On the basis of experience gathered by various European research laboratories, a miniature specimen construction procedure has been developed using a laser welding technique for joining threaded heads to sample material. Low alloy ferritic steels, such as virgin 2.25CrlMo, 0.5Cr 0.5Mo 0.25V, and IN 738 superalloy miniature specimens have been investigated and the results, compared with those from standard specimens, show a regular trend in deformation vs time. Additional efforts to provide guidelines for material sampling from each plant component will be required in order to reduce uncertainties in residual life prediction.

  1. Assessment of the stability of DNA in specimens collected under conditions for drug testing-A pilot study.

    Science.gov (United States)

    White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley

    2018-02-01

    For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Effects of crack front curvature on J–R curve testing using clamped SE(T) specimens of homogeneous materials

    International Nuclear Information System (INIS)

    Huang, Yifan; Zhou, Wenxing

    2015-01-01

    Three-dimensional (3D) finite element analyses (FEA) of clamped single-edge tension (SE(T)) specimens are performed to investigate the impact of the crack front curvature on the elastic compliance, compliance rotation correction factor and average J-integral evaluated over the crack front. Specimens with six average crack lengths (i.e. a_a_v_e/W = 0.2–0.7) and three thickness-to-width ratios (i.e. B/W = 0.5, 1 and 2) are analyzed. The curved crack front is assumed to be bowed symmetrically and characterized by a power-law expression with a wide range of curvatures. Several crack front straightness requirements for SE(B) and C(T) specimens specified in BS7448, ISO and ASTM E1820 standards are reviewed. Based on results of the numerical investigation, new crack front straightness criteria for the SE(T) specimen are proposed in the context of the nine-point measurement by using as a criterion that the errors in the estimated compliance and average J values should be no more than five percent. The proposed criteria depend on both a_a_v_e/W and B/W, and are more advantageous than those specified in the BS, ISO and ASTM standards in terms of controlling the differences in J and compliance between the specimens with curved and straight crack fronts. - Highlights: • Investigate the impacts of crack front curvature on the compliance, rotation correction factor and J for SE(T) specimens. • Validate the applicabilities of crack front straightness criteria specified in the seven test standards on SE(T) specimens. • Recommend new crack front straightness criteria for the SE(T) specimen.

  3. Development of a Small Punch Test Technique for an Evaluation of the Mechanical Properties of Irradiated Materials in a Hot Cell

    International Nuclear Information System (INIS)

    Kim, Do-Sik; Ahn, Sang-Bok; Yoo, Byung-Ok; Choo, Yong-Sun; Hong, Kwon-Pyo

    2006-01-01

    Miniaturized specimens have been widely used to evaluate the mechanical properties of steels and plastics. Especially for a study on the irradiation effects in nuclear materials, the small specimen test techniques have attracted considerable attention. Therefore, it is essential that the test techniques be developed and verified to extract the mechanical properties information from small specimens. Among the test techniques using small specimens, the small punch (SP) test technique using small disc-sized specimen has been successfully used to estimate the tensile properties (yield strength and ultimate tensile strength), DBTT (ductile-brittle transition temperature), fracture toughness and creep properties of metals irradiated in a reactor or a proton accelerator. In this paper, the existing SP test techniques are reviewed and summarized. In addition, the information on the development of the SP test procedure is obtained to evaluate the radiation effects on the mechanical properties of nuclear materials in a hot cell

  4. Assessment of strength characteristics of Al2024 ECAP metal using small punch testing

    International Nuclear Information System (INIS)

    Ma, Young Wha; Choi, Jeong Woo; Yoon, Kee Bong; Kim, Seon Hwa

    2006-01-01

    When subjected to severe shear deformation by ECAP, microstructure of Al2024 becomes extremely refined. To measure the strength of that, Small Punch(SP) testing method was adopted as a substitute for the conventional uniaxial tensile testing because the size of material processed by ECAP were limited to ψ12 mm in transverse direction. SP tests were performed with specimens in longitudinal and transverse directions of Al2024 ECAP metal. For comparing the strength values with those assessed by SP tests, uniaxial tensile tests were also conducted with specimens in longitudinal direction. Failure surfaces of the tested SP specimens showed that failure mode was shear deformation and Al2024 ECAP metal has an anisotropy in strength. Thus, conventional equations proposed for assessing the strength characteristics were improper to assess those of Al2024 ECAP metal. In this paper a way of assessing the strength of Al2024 ECAP metal was proposed and was proven to be effective

  5. C.O.D. toughness testing of medium strength steel as a preliminary development for single specimen J integral toughness tests of SA533-B steel

    International Nuclear Information System (INIS)

    Dean, P.; Tait, R.B.; Garrett, G.G.

    1981-10-01

    The primary purpose of this project is to set up a test facility and to develop the necessary expertise to enable reliable elasto-plastic fracture toughness tests to be performed. Initially, tests are to be conducted on material similar to that used in the Koeberg pressure vessel walls, with the ultimate goal of performing single specimen J integral tests on the pressure vessel steel itself to determine through-thickness toughness variations. The project will comprise a number of stages, each one necessary for the development of the techniques used in J integral testing. These include: (i) development of an appropriate specimen design, of suitable size and shape that is applicable to both crack opening displacement (C.O.D.) and J integral tests; (ii) development, testing and calibration of the necessary associated mechanical and electrical equipment (e.g. clip gauge, amplifiers, interface unit, etc.), with (iii) an estimation of the probable errors and noise levels with a view to their elimantion, leading to (iv) perfection of the sensitivity and reproducibility of, firstly, the multiple specimen C.O.D. technique and, secondly, the multiple specimen J integral techniques. (v) Based on the above techniques, development of the single specimen J integral test method incorporating development of a computerised testing procedure. All the above procedure is to be conducted on similar, but non-Koeberg pressure vessel material ('ROQ Tough'). (vi) Finally, development and testing of both multiple specimen and single specimen J integral tests on actual SA533B material and an investigation of the through thickness toughness and fatigue crack propagation behaviour

  6. Using an AMACR (P504S)/34betaE12/p63 cocktail for the detection of small focal prostate carcinoma in needle biopsy specimens.

    Science.gov (United States)

    Jiang, Zhong; Li, Cuizhen; Fischer, Andrew; Dresser, Karen; Woda, Bruce A

    2005-02-01

    We assessed the usefulness of immunohistochemical analysis with a 3-antibody cocktail (alpha-methylacyl coenzyme A racemase [AMACR, or P504S], 34betaE12, p63) and a double-chromogen reaction for detection of limited prostate cancer in 138 needle biopsy specimens, including 82 with small foci of prostatic adenocarcinoma and 56 benign prostates. When carcinoma was present, red cytoplasmic granular staining (AMACR) in the malignant glands and cells and dark brown nuclear (p63) and cytoplasmic (34betaE12) staining in basal cells of adjacent nonmalignant glands were found. Of 82 cases of small foci of prostatic adenocarcinoma, 78 (95%) expressed AMACR; all malignant glands were negative for basal cell staining. All benign glands adjacent to malignant glands were recognized easily by basal cell marker positivity and little or no AMACR expression. No benign glands were simultaneously positive for AMACR and negative for basal cell markers (specificity, 100%). There were no differences in intensity and numbers of positive glands with double-chromogen staining compared with using 1-color staining. Our results indicate that immunohistochemistry with a 3-antibody cocktail and double chromogen is a simple and easy assay that can be used as a routine test, which overcomes the problems of studying small lesions in prostate needle biopsies with multiple immunohistochemical stains.

  7. Illustration of the WPS benefit through BATMAN test series: Tests on large specimens under WPS loading configurations

    International Nuclear Information System (INIS)

    Yuritzinn, T.; Ferry, L.; Chapuliot, S.; Mongabure, P.; Moinereau, D.; Dahl, A.; Gilles, P.

    2008-01-01

    To study the effects of warm pre-stressing on the toughness of reactor pressure vessel steel, the 'Commissariat a l Energie Atomique', in collaboration with 'Electricite de France' and AREVA-NP, has made a study combining modeling and a series of experiments on large specimens submitted to a thermal shock or isothermal cooling. The tests were made on 18MND5 ferritic steel bars, containing a short or large fatigue pre-crack. The effect of 'warm pre-stressing' was confirmed, in the two cases of a fast thermal shock creating a gradient across the thickness of the bar and for gradual uniform cooling. In both cases, no propagation was observed during the thermal transient. Fracture occurred under low temperature conditions, at the end of the test when the tensile load was increased. The failure loads recorded were substantially higher than during pre-stressing. To illustrate the benefit of the WPS effect, numerical interpretations were performed using either global approach or local approach criteria. WPS effect and capability of models to predict it were then clearly shown. (authors)

  8. Small punch creep test in a 316 austenitic stainless steel

    Directory of Open Access Journals (Sweden)

    Saucedo-Muñoz, Maribel L.

    2015-03-01

    Full Text Available The small punch creep test was applied to evaluate the creep behavior of a 316 type austenitic stainless steel at temperatures of 650, 675 and 700 °C. The small punch test was carried out using a creep tester with a specimen size of 10×10×0.3 mm at 650, 675 and 700 °C using loads from 199 to 512 N. The small punch creep curves show the three stages found in the creep curves of the conventional uniaxial test. The conventional creep relationships which involve parameters such as creep rate, stress, time to rupture and temperature were followed with the corresponding parameters of small punch creep test and they permitted to explain the creep behavior in this steel. The mechanism and activation energy of the deformation process were the grain boundary sliding and diffusion, respectively, during creep which caused the intergranular fracture in the tested specimens.El ensayo de termofluencia por indentación se utilizó para evaluar el comportamiento a la termofluencia en un acero inoxidable austenítico 316. Este ensayo se realizó en una máquina de indentación con muestras de 10×10×0,3 mm a temperaturas de 650, 675 y 700 °C con cargas de 199 a 512 N. Las curvas de termofluencia del ensayo mostraron las tres etapas características observadas en el ensayo convencional de tensión. Asimismo, las principales relaciones de termofluencia entre parámetros como velocidad de termofluencia, esfuerzo, tiempo de ruptura y temperatura se observaron en los parámetros correspondientes al ensayo de indentación, lo que permitió caracterizar el comportamiento de termofluencia en este acero. El mecanismo y la energía de activación del proceso de deformación en la termofluencia corresponden al deslizamiento de los límites de grano y la difusión a través de los mismos, respectivamente, lo cual causó la fractura intergranular en las muestras ensayadas.

  9. Study of residual stresses in CT test specimens welded by electron beam

    Science.gov (United States)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  10. Development of specimen size and test rate effects on the J-integral upper transition behavior of A533B steel

    International Nuclear Information System (INIS)

    Joyce, James A.

    1988-01-01

    During the past three years a test method has been developed for dynamic testing of fracture mechanics specimens which is specifically designed for application to the upper transition temperature range. The method uses drop tower loading rates of 2.5 m/sec and obtains a J IC or a J-R curve using an analytical key curve approach verified by initial and final crack length measurements obtained from the fracture surface. A J-R curve is obtained from each specimen and contains crack growth corrections so that it is directly comparable with static results obtained in accordance with the ASTM E1152 J-R curve test method. The test procedure has been applied to A106 steel, A533B steel and US Navy HY80 and HY100 steels at temperatures from -200F to 150F. Standard 1T three point bend specimens were used for the A533B and the HY100 steel. Static test results have shown that the J at cleavage initiation (which is presently an unstandardized quantity) is specimen a/W independent throughout the ductile to brittle transition but of course demonstrates considerable statistical scatter in the vicinity of the ductile upper shelf. Dynamic J-R tests have shown an increase in J IC with test rate for most, but not for all, materials. Separation of J into elastic and plastic components shows that the elastic J component increases with test rate in a fashion consistent with the materials tensile sensitivity to test rate but the plastic J component decreases with test rate - an apparent visco-plastic phenomena. For A106 steel the plastic J decrease exceeds the elastic J increase and the upper shelf toughness falls - while the other materials have demonstrated a relatively larger increase in the elastic J component and a smaller decrease in the plastic J component giving an overall increase in upper shelf toughness. Separation of the J integral into elastic and plastic components has demonstrated that J EL is specimen scale and geometry dependent while J PL is relatively scale and geometry

  11. 9 CFR 93.204 - Import permits for poultry and for poultry test specimens for diagnostic purposes; and...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Import permits for poultry and for poultry test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  12. Development and validation of the small punch test for UHMWPE used in total joint replacements

    Energy Technology Data Exchange (ETDEWEB)

    Edidin, A.A. [Drexel Univ., Philadelphia, PA (United States). School of Biomedical Engineering, Science and Health Systems; Howmedica Osteonics Corp., Allendale, NJ (United States); Kurtz, S.M. [Drexel Univ., Philadelphia, PA (United States). School of Biomedical Engineering, Science and Health Systems; Thomas Jefferson Univ., Philadelphia, PA (United States). Dept. of Orthopaedic Surgery; Exponent, Inc., Philadelphia, PA (United States)

    2001-07-01

    In order to better understand the mechanical effects of oxidative degradation, improved oxidative stability and crosslinking on ultra-high molecular weight polyethylene (UHMWPE), a unique miniature specimen mechanical testing technique, known as the small punch test, was developed for evaluating total joint replacement components. The small punch test involves deforming a disk-shaped specimen having a thickness of 0.5 mm and a diameter of 6.4 mm. In addition to its small specimen size, the small punch test differs from conventional testing in that deformation of the UHMWPE specimen occurs under multiaxial loading conditions. Using the small punch test, we have traced the evolution of mechanical behavior in UHMWPE after natural (shelf-storage) and accelerated aging conditions. In addition, we have determined relationships between the mechanical behavior of UHMWPE and the biologically relevant wear debris volume generated in total hip replacements. The small punch test has also been used to investigate the effects of radiation crosslinking which has been shown to improve the wear performance in an in vitro hip simulator. However, the crosslinking and subsequent thermal processes used to improve the wear behavior may compromise the native mechanical behavior by changing the ductility and toughness of the UHMWPE bearing. The primary objective of this study was to investigate which tradeoffs exist related to the mechanical behavior associated with various clinically available types of highly crosslinked and thermally treated UHMWPE. We also review the development and validation of the small punch disk bend test and highlight its application to problems of clinical relevance in both hip and knee arthroplasty. (orig.)

  13. 49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection

    Science.gov (United States)

    2010-10-01

    ... the transfer of the blood tubes on the second line of STEP 5 (the chain of custody block). E. Collect... (the chain of custody block). F. Seal the Individual Employee Kit a. The blood and urine specimens have... railroad representatives handling the box shall document chain of custody of the shipping box and shall...

  14. Irradiation of UO2 specimens with molten cores in a pressurized water loop. Test X-2-x

    International Nuclear Information System (INIS)

    Bain, A.S.

    1961-08-01

    Two Zircaloy-2 clad specimens containing stoichiometric UO 2 pellets were irradiated in a pressurized water loop for 379 hours at heat ratings sufficient to cause central melting of the UO 2 . There was no appearance of localized overheating or accelerated corrosion of the sheath, but the diametral increases were considerably larger than those observed in loop specimens irradiated at lower heat ratings. The length increases, however, were approximately the same as those measured for specimens at lower ratings. There was a clearly visible demarcation between UO 2 that had been molten and that which had not. The value of ∫ 500 o C Tm kdθ = 74 ± W/cm was essentially the same as that obtained from the short-duration tests in the Hydraulic Rabbit, indicating there is no marked decrease in thermal conductivity of the UO 2 fuel in irradiations up to 379 hours. (author)

  15. Beryllium irradiation embrittlement test programme. Material and specimen specification, manufacture and qualification

    International Nuclear Information System (INIS)

    Harries, D.R.; Dalle Donne, M.

    1996-06-01

    The report presents the specification, manufacture and qualification of the beryllium specimens to be irradiated in the BR2 reactor in Mol to investigate the effect of the neutron irradiation on the embrittlement as a function of temperature and beryllium oxide content. This work was been performed in the framework of the Nuclear Fusion Project of the Forschungszentrum Karlsruhe and is supported by the European Union within the European Fusion Technology Program. (orig.)

  16. Small Scale Hydrocarbon Fire Test Concept

    Directory of Open Access Journals (Sweden)

    Joachim Søreng Bjørge

    2017-11-01

    Full Text Available In the oil and gas industry, hydrocarbon process equipment was previously often thermally insulated by applying insulation directly to the metal surface. Fire protective insulation was applied outside the thermal insulation. In some cases, severe corrosion attacks were observed due to ingress of humidity and condensation at cold surfaces. Introducing a 25 mm air gap to prevent wet thermal insulation and metal wall contact is expected to solve the corrosion issues. This improved insulation methodology does, however, require more space that may not be available when refurbishing older process plants. Relocating structural elements would introduce much hot work, which should be minimized in live plants. It is also costly. The aim of the present study is therefore to develop a test concept for testing fire resistance of equipment protected with only air-gap and thermal insulation, i.e., without the fire-protective insulation. The present work demonstrates a conceptual methodology for small scale fire testing of mockups resembling a section of a distillation column. The mockups were exposed to a small-scale propane flame in a test configuration where the flow rate and the flame zone were optimized to give heat flux levels in the range 250–350 kW/m2. Results are presented for a mockup resembling a 16 mm thick distillation column steel wall. It is demonstrated that the modern distance insulation in combination with the heat capacity of the column wall indicates 30+ minutes fire resistance. The results show that this methodology has great potentials for low cost fire testing of other configurations, and it may serve as a set-up for product development.

  17. Dynamic Toughness Testing of Pre-Cracked Charpy V-Notch Specimens. Convention ELECTRABEL - SCK-CEN

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E

    1999-04-01

    This document describes the experimental and analytical procedures which have been adopted at the laboratories of the Belgian Nuclear Research Centre SCK-CEN for performing dynamic toughness tests on pre-cracked Charpy-V specimens. Such procedures were chosen on the basis of the existing literature on the subject, with several updates in the data analysis stages which reflect more recent developments in fracture toughness testing. Qualification tests have been carried out on PCCv specimens of JRQ steel, in order to assess the reliability of the results obtained; straightforward comparisons with reference data have been performed, as well as more advanced analyses using the Master Curve approach. Aspects related to machine compliance and dynamic tup calibration have also been addressed.

  18. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    Energy Technology Data Exchange (ETDEWEB)

    Saeidi, N., E-mail: navidsae@gmail.com [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Ashrafizadeh, F.; Niroumand, B. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Forouzan, M.R.; Mohseni mofidi, S. [Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Barlat, F. [Materials Mechanics Laboratory (MML), Graduate Institute of Ferrous Technology (GIFT), Pohang University of Science and Technology POSTECH, San 31 Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784 (Korea, Republic of)

    2015-09-17

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models.

  19. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    International Nuclear Information System (INIS)

    Saeidi, N.; Ashrafizadeh, F.; Niroumand, B.; Forouzan, M.R.; Mohseni mofidi, S.; Barlat, F.

    2015-01-01

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models

  20. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  1. Investigation of smooth specimen scc test procedures; variations in environment, specimen size, stressing frame, and stress state. [for high strength aluminum alloys

    Science.gov (United States)

    Lifka, B. W.; Sprowls, D. O.; Kelsey, R. A.

    1975-01-01

    The variables studied in the stress-corrosion cracking performance of high strength aluminum alloys were: (1) corrosiveness of the environment, (2) specimen size and stiffness of the stressing system, (3) interpretation of transgranular cracking, and (4) interaction of the state of stress and specimen orientation in a product with an anisotropic grain structure. It was shown that the probability of failure and time to fracture for a specimen loaded in direct tension are influenced by corrosion pattern, the stressing assembly stiffness, and the notch tensile strength of the alloy. Results demonstrate that the combination of a normal tension stress and a shear stress acting on the plane of maximum susceptibility in a product with a highly directional grain cause the greatest tendency for stress-corrosion cracking.

  2. Visualization test using piping group mock up specimen for evaluation of wastage phenomena in steam generator for FBR

    International Nuclear Information System (INIS)

    Kato, Keisuke; Yoshida, Atsuro; Arae, Kunihiko; Narabayashi, Tadashi; Ohshima, Hiroyuki; Kurihara, Akikazu

    2012-01-01

    There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code. (author)

  3. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  4. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  5. Characterizing the transition region of an A508 cl3 steel using small specimens by the reference temperature and the weak-link distances

    International Nuclear Information System (INIS)

    Miranda, C.A.J.

    2001-01-01

    An experimental program was developed to characterize the transition region of an A508 cl3 steel. Some fracture mechanic specimens were tested in the transition region using three geometries with thickness B c values, the reference temperature values, To, associated with each geometry and test temperature, and the measured r wl distances and the theoretical ones. (author)

  6. Method for efficient storage and transportation of sputum specimens for molecular testing of tuberculosis.

    Science.gov (United States)

    Guio, H; Okayama, H; Ashino, Y; Saitoh, H; Xiao, P; Miki, M; Yoshihara, N; Nakanowatari, S; Hattori, T

    2006-08-01

    The polymerase chain reaction (PCR) is a highly sensitive method for the detection of Mycobacterium tuberculosis and is available in most countries, though to a lesser extent in rural areas. To amplify M. tuberculosis DNA sequences of sputum spotted on FTA cards and compare them with the results of microscopic examination among culture-positive samples. A total of 102 sputum specimens of TB patients in treatment were spotted on FTA cards and stored at room temperature until DNA analysis. We assessed the IS6110 region of M. tuberculosis. The efficacy of the PCR assay for the direct detection of M. tuberculosis was evaluated and compared with the results of cultures (Middlebrook 7H9 broth) and smears of fresh sputum specimens. We were able to detect 10 fg/microl of mycobacterial DNA even after 6 months in storage. The PCR sensitivity and specificity using the FTA card system were 82% and 96%, while microscopic examination showed 41% and 95%, respectively. The FTA card system for the storage of bacterial DNA from sputum samples should be considered for the molecular diagnosis of tuberculosis. Samples can easily be obtained from geographically isolated populations and shipped by mail for accurate molecular diagnosis.

  7. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  8. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    Science.gov (United States)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  9. Influence Of The Gripping Fixture On The Modified Compact Tension Test Results: Evaluation Of The Experiments On Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Holušová Táňa

    2015-12-01

    Full Text Available The modified compact tension test (MCT might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced.

  10. Design, Fabrication and Test Report on a Verification Capsule (05M-06K) for the Control of a Neutron Irradiation Fluence of Specimens in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Choi, M. H.; Lee, D. S.

    2007-02-15

    As a part of a project for a capsule development and utilization for an irradiation test, a verification capsule (05M-06K) was designed, fabricated and tested for the development of new instrumented capsule technology for a more precise control of the irradiation fluence of a specimen, irrespective of the reactor operation condition. The basic structure of the 05M-06K capsule was based on the 04M-22K mock-up capsule which was successfully designed and out-pile tested to confirm the various key technologies necessary for the fluence control of a specimen. 21 square and round shaped specimens made of STS 304 were inserted into the capsule. The capsule was constructed in 5 stages with specimens and an independent electric heater at each stage. Each of the five specimens which were accommodated in the 1st stage (top) of the capsule can be taken out of the HANARO core during a normal reactor operation. The specimen is extracted by a specimen extraction mechanism using a steel wire. During the out-pile test, the temperatures of the specimens were measured by 12 thermocouples installed in the capsule. The capsule was successfully out-pile tested in a single channel test loop. The obtained results will be used for a safety evaluation of the new irradiation capsule for controlling the irradiation fluence of specimens in HANARO.

  11. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  12. Cassini RTG's -- Small scale module tests

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1994-01-01

    The Cassini spacecraft, scheduled for a 1997 launch to Saturn, will be powered by three GPHS RTGs (General Purpose Heat Source Radioisotope thermoelectric Generators). The RTGs are the same type as those powering the Galileo and Ulysses spacecraft. Three new converters (F-6, F-7, and F-8) are to be built and one converter (F-2) remaining from the GPHS program will be used. F-6 and F-7 are to be fueled and F-8 serves as a spare converter. In addition, the back-up RTG (F-5) from the Ulysses launch, which is still fueled, will serve as the Cassini back-up RTG. The new RTGs will have a lower fuel loading than in the past and will provide a minimum of 276 watts each at B.O.M. (beginning of mission). The mission length is 10.75 years, at which time these RTGs will provide a minimum of 216 watts and a possible extension to 16 years when the power will be 199 watts. This paper discusses tests performed to date to confirm the successful re-establishment of the unicouple production at Martin Marietta. This production line, shut down 10 years ago, has been restarted and over 1,500 unicouples have been produced to date. Confirmation will be primarily obtained by the performance of three small scale converters in comparison with previously tested modules from the Multi Hundred Watt (MHW) (Voyager) and GPHS (Galileo, Ulysses) programs. Test results to date have shown excellent agreement with the data base

  13. 46 CFR 57.04-1 - Test specimen requirements and definition of ranges (modifies QW 202, QW 210, QW 451, and QB 202).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Test specimen requirements and definition of ranges... HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Procedure Qualification Range § 57.04-1 Test specimen requirements and definition of ranges (modifies QW 202, QW 210, QW 451, and QB 202...

  14. Evaluation of toughness degradation by small punch (SP) tests for neutron irradiated structural steels

    International Nuclear Information System (INIS)

    Misawa, Toshihei; Hamaguchi, Yoshikazu; Kimura, Akihiko; Eto, Motokuni; Suzuki, Masahide; Nakajima, Nobuya.

    1992-01-01

    The small punch (SP) test as one of the useful small specimen testing technique (SSTT) has been developed to evaluate the fracture toughness, ductile-brittle transition temperature (DBTT) and tensile properties for neutron irradiated structural materials. The SP tests using the miniaturized specimens of φ3 mm TEM disk and 10 mm 2 coupon were performed for six kinds of ferritic steels of F-82, F-82H, HT-9, JFMS, 2.25-1Mo and SQV2A. It was shown that the temperature dependence of SP fracture energies with scatter in miniaturized testing can give reliable information on the DBTT by use of the statistical analysis based on the Weibull distribution. A good correlation between the DBTT of the SP tests and that of the standard CVN test has been obtained for the various nuclear ferritic steels. The SP test was performed for cryogenic austenitic steels as a way of evaluating elastic-plastic fracture toughness, J IC , on the basis of a universal empirical relationship between J IC and SP equivalent fracture strain, ε-bar qf . The SP testing using the neutron irradiated specimens of 2.25Cr-1Mo, F-82, F-82H and HT-9 steels was successfully applied and presented the neutron radiation induced changes on the DBTT, fracture toughness and tensile properties. (author)

  15. Three-axial strain controlled testing applied to bone specimens from the proximal tibial epiphysis

    DEFF Research Database (Denmark)

    Linde, F.; Pongsoipetch, B.; Frich, Lars Henrik

    1990-01-01

    Reproducibility of the determination of Young's modulus and energy absorption along the three axes of trabecular bone cubes was analysed by non-destructive compression to 0.5% strain using different testing protocols. These protocols included testing with and without pre-conditioning to a viscoel......Reproducibility of the determination of Young's modulus and energy absorption along the three axes of trabecular bone cubes was analysed by non-destructive compression to 0.5% strain using different testing protocols. These protocols included testing with and without pre...

  16. Evaluation of constraint methodologies applied to a shallow-flaw cruciform bend specimen tested under biaxial loading conditions

    International Nuclear Information System (INIS)

    Bass, B.R.; McAfee, W.J.; Williams, P.T.; Pennell, W.E.

    1998-01-01

    A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a prototypic, far-field. out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for RPV materials. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies. namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness, the conventional maximum principal stress criterion indicated no effect

  17. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Directory of Open Access Journals (Sweden)

    Hongxue Luo

    Full Text Available Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample.Two cervico-vaginal specimens (pseudo self-collected were obtained from 319 women. One was applied to an iFTA Card (FTA then the brush placed in liquid-based medium (LSELF; the other was applied to a new solid media: POI card (POI. The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC.The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC, 81.0% (FTA vs. LDOC, and 82.3% (POI vs. LDOC. LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF, 73.8% (FTA, 95.1% (POI, and 93.4% (LDOC respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both.Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  18. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Science.gov (United States)

    Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang

    2016-01-01

    Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  19. Analysis of radioactive corrosion test specimens by means of ICP-MS. Comparison with earlier methods

    International Nuclear Information System (INIS)

    Forsyth, Roy

    1997-07-01

    In June 1992, an ICP-MS instrument (Inductively Coupled Plasma-Mass Spectrometry) was commissioned for use with radioactive sample solutions at Studsvik Nuclear's Hot Cell Laboratory. For conventional environmental samples the instrument permits the simultaneous analysis of many trace elements, but the software used in evaluation of the mass spectra is based on a library of isotopic compositions relevant only for elements in the lithosphere. Fission products and actinides, however, have isotopic compositions which are significantly different from the natural elements, and which also vary with the burnup of the nuclear fuel specimen. Consequently, a spread-sheet had to be developed which could evaluate the mass spectra with these isotopic compositions. Following these preparations, a large number of samples (about 200) from SKB's experimental programme for the study of spent fuel corrosion have been analyzed by the ICP-MS technique. Many of these samples were archive solutions of samples which had been taken earlier in the programme. This report presents a comparison of the analytical results for uranium, plutonium, cesium, strontium and technetium by both the ICP-MS technique, and the previously used analytical methods. For three products, a satisfactory agreement between the results from the various methods was obtained, but for uranium and plutonium the ICP-MS method gave results which were 10-20% higher than the conventional methods. The comparison programme has also shown, not unexpectedly, that significant losses of plutonium from solution had occurred, by precipitation and/or absorption, in the archive solutions during storage. It can be expected that such losses also occur for the other actinides, and consequently, all the analytical results for actinides in older archive solutions must be treated with great caution. 9 refs

  20. Development of a miniaturized bulge test (small punch test) for post-irradiation mechanical property evaluation

    International Nuclear Information System (INIS)

    Eto, Motokuni; Suzuki, Masahide; Nishiyama, Yutaka; Fukaya, Kiyoshi; Jitsukawa, Shiro; Misawa, Toshihei

    1993-01-01

    To examine the effectiveness of the small punch test for evaluating strength and toughness of irradiated ferritic steels, detailed procedures are described aiming at standardization of the test. The statistical approach to analysis of the SP energy as a function of temperature for evaluation of DBTT was also reviewed. The method was then applied to neutron-irradiated ferritic steels, which included F-82, F-82H, HT-9, and 2 1/4 Cr-1Mo steel. Fluence and irradiation temperatures ranged from 2 to 12 x 10 23 n/m 2 (E ≥ 1 MeV) and from 573 to 673 K, respectively. Comparison of parameters obtained from the small punch test with the properties measured by the conventional method indicated that: (a) the 0.2% offset stress and the ultimate tensile strength at room temperature can be correlated well with the parameters, P y /(t 0 ) 2 and P max /(t 0 ) 2 , respectively. Here, P y and P max are the loads corresponding to the yield and the maximum, and t 0 is the initial thickness of a specimen; (b) fracture toughness, J IC , can be evaluated using equivalent fracture strain, anti ε qf , and the previously established relationship between these values; and (c) DBTT measured by a Charpy test can be predicted from the results of temperature dependence of SP energy determined from the area under the load-deflection curve using a statistical analysis based on a Weibull distribution

  1. Horizontal loading test by whole model specimen simulating inner concrete structure of PWR type nuclear power plant

    International Nuclear Information System (INIS)

    Furuya, Noriyuki; Sekine, Masataka; Kimura, Kozo; Yamaguchi, Yoshihiro; Yamaguchi, Tsuneo; Takeda, Toshikazu

    1985-01-01

    The Nuclear Power Engineering Test Center has performed a horizontal loading test by a whole model specimen simulating the inner concrete structure of a PWR type nuclear power plant in order to investigate restoring force characteristics of reactor buildings. This report describes the results of examination of applicability to the test results of analysis methods based on elastic theory. The analysis results of elastic stiffness, concrete cracking load, rebar yielding loads and ultimate strength were compared with the test results. According to this examination, it is recognized that even these analysis methods based on elastic theory are comparatively effective for analysis of an inner concrete structure of fairly complex configuration, although there are limits of the scope of applicability. (author)

  2. The distinct element analysis for swelling pressure test of bentonite. Discussion on the effects of wall friction force and aspect ratio of specimen

    International Nuclear Information System (INIS)

    Shimizu, Hiroyuki; Kikuchi, Hirohito; Fujita, Tomoo; Tanai, Kenji

    2011-10-01

    For geological isolation systems for radioactive waste, bentonite based material is assumed to be used as a buffer material. The swelling characteristics of the bentonite based material are expected to fill up the void space around the radioactive wastes by swelling. In general, swelling characteristics and properties of bentonite are evaluated by the laboratory tests. However, due to the lack of standardization of testing method for bentonite, the accuracy and reproducibility of the testing results are not sufficiently proved. In this study, bentonite swelling pressure test were simulated by newly developed Distinct Element Method (DEM) code, and the effects of wall friction force and aspect ratio of bentonite specimen were discussed. As a result, the followings were found. In the beginning of the swelling pressure test, since swelling occurs only around the fluid injection side of the specimen, wall friction force acts only in the swelling area and the specimen moves to opposite side from fluid injection side. However, when the entire specimen started swelling, displacement of the specimen prevented by the wall friction force, and the specimen is pressed against the pressure measurement side. Then, the swelling pressure measured on the pressure measurement side increases. Such displacement in the specimen is significantly affected by the decreasing of mechanical properties and the difference of saturation in the bentonite specimen during the fluid infiltration. Moreover, when the aspect ratio of the specimen is large, the displacement of the particle in the specimen becomes large and the area on which the wall frictional force acts is also large. Therefore, measured swelling pressure increases more greatly as the aspect ratio of the specimen increases. To contributes to the standardization of laboratory test methods for bentonite, these effects of wall friction force revealed by the DEM simulation should be verified through laboratory experiments. (author)

  3. Recent advances on Charpy specimen reconstitution techniques

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  4. Recent advances on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  5. Formulation of a new model of dynamic cracking in PLEXUS. First applications to a laboratory test specimen

    International Nuclear Information System (INIS)

    Jamet, P.

    1986-07-01

    The problem of dynamic rupture is important for nuclear power plant safety analysis, more particularly in case of cold shock in a PWR vessel. Preliminary studies showed that PLEXUS is a numerical frame well adapted to the analysis of the problem. The aim of this report is to present a new model implemented in PLEXUS, for a better simulation of splitting. A first trial taking into account the variation of the dynamic toughness versus crack propagation rate has been done (samples of steel AISI 4340). The model has been applied to the dynamic cracking of a test specimen. The influence of wave reflections at the structure limits has been clearly pointed out [fr

  6. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 This test method describes an accurate technique for measuring the normal spectral emittance of electrically nonconducting materials in the temperature range from 1000 to 1800 K, and at wavelengths from 1 to 35 μm. It is particularly suitable for measuring the normal spectral emittance of materials such as ceramic oxides, which have relatively low thermal conductivity and are translucent to appreciable depths (several millimetres) below the surface, but which become essentially opaque at thicknesses of 10 mm or less. 1.2 This test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is particularly suitable for research laboratories, where the highest precision and accuracy are desired, and is not recommended for routine production or acceptance testing. Because of its high accuracy, this test method may be used as a reference method to be applied to production and acceptance testing in case of dispute. 1.3 This test metho...

  7. Propagation of fractures from an interface in a Brazilian test specimen

    CSIR Research Space (South Africa)

    Malan, DF

    1994-12-01

    Full Text Available by Berenbaum and Brodie \\[4\\]. If a circular disc of radius R and unit thickness is compressed across a diameter by line loads W as shown in Fig. 2(a), the stresses on this diameter are given by Jaeger and Cook \\[5\\] as W ~' ~R (1) - W(3R z + x 2) a.... SIMULATION OF FRACTURE GROWTH Numerical simulation of fracture growth using small- strain dislocation theory has been reported by a number of workers, for example Cornet \\[11\\], Sun et al. \\[12\\] and Thomas and Pollard \\[13\\]. The technique used...

  8. Shear compression testing of glass-fibre steel specimens after 4K reactor irradiation: Present status and facility upgrade

    International Nuclear Information System (INIS)

    Gerstenberg, H.; Kraehling, E.; Katheder, H.

    1997-01-01

    The shear strengths of various fibre reinforced resins being promising candidate insulators for superconducting coils to be used tinder a strong radiation load, e.g. in future fusion reactors were investigated prior and subsequent to reactor in-core irradiation at liquid helium temperature. A large number of sandwich-like (steel-bonded insulation-steel) specimens representing a widespread variety of materials and preparation techniques was exposed to irradiation doses of up to 5 x 10 7 Gy in form of fast neutrons and γ-radiation. In a systematic study several experimental parameters including irradiation dose, postirradiation storage temperature and measuring temperature were varied before the determination of the ultimate shear strength. The results obtained from the different tested materials are compared. In addition an upgrade of the in-situ test rig installed at the Munich research reactor is presented, which allows combined shear/compression loading of low temperature irradiated specimens and provides a doubling of the testing rate

  9. High temperature strength analysis of welded joint of RAF's by small punch test

    Energy Technology Data Exchange (ETDEWEB)

    Kato, T. [Muroran Institute of Technology, Dept. of Materials Science and Engineeering, Hokkaido (Japan); Komazaki, S.; Kohno, Y. [Muroran Institute of Technology, Muroran (Japan); Tanigawa, H. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Kohyama, A. [Kyoto Univ., Institute of Advanced Energy (Japan)

    2007-07-01

    Full text of publication follows: Nucleation and growth of microvoids and/or small cracks in fine-grained heat affected zone (HAZ) after long-term service operation, which is recognized as Type IV creep damage, has recently been a worldwide issue for high Cr ferritic steels. In our group, a small punch (SP) creep test has been successfully applied to evaluate this damage of low alloy ferritic steel. However, the HAZ of fusion reactor material welded by electron-beam (EB) welding is so narrow that it is not easy to evaluate its mechanical properties by conventional tests including the SP creep test with a plate-type specimen (10 x 10 x 0.5 mm{sup 3}). In this study, the SP creep test using a further miniaturized specimen was developed and applied to the welded joint of reduced activation ferritic steels (RAFs), F82H-IEA (Fe-8Cr-2W-0.2V-0.02Ta), for measuring creep properties of the HAZ. For the SP creep test, TEM disk-type samples (diam. 3.0 x 0.30 mm) were removed from the base metal (BM), weld metal (WM) and HAZ, respectively. The specimen surfaces were polished up to a 0.05 {mu}m alumina powder finish and the specimen's thickness was finally adjusted to 0.25 mm. The SP creep tests were performed at temperatures of 823{approx}973 K and under loads ranging from 20 to 200 N. A constant load was applied to the center of the specimen through the Si{sub 3}N{sub 4} bail (diam. 1.0 mm) using the electric servo motor. The central deflection of the specimen was monitored by measuring the displacement of the compression rod. The tests were carried out in an argon gas atmosphere and the gas was continuously passed through during the test to prevent severe oxidation of the specimen. The differences in SP creep properties such as rupture time and minimum creep rate between the BM, WM and HAZ were discussed in terms of microstructural changes during welding thermal cycles. In addition, the result obtained from the BM was correlated with those of uniaxial creep test

  10. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  11. Fracture Characterization of PVC Foam Core Sandwich Specimen Using the DCB-UBM Test Method

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Berggreen, Christian; Carlsson, Leif A.

    coupled with experimental validation is paramount to determine the fracture resistance of the face/core interface. In this paper, the test-rig exploiting the double cantilever beam with uneven bending moments (DCB-UBM) concept is used to determine the fracture toughness of PVC foam core sandwich......Face/core debond failure in sandwich composites is a critical failure mode. Lack of cohesion between face and core will lead to loss of structural integrity. The estimation of interface fracture toughness especially at the face/core interface is extremely challenging, provided the dissimilarity...... composites. The DCB-UBM test enables fracture testing over a large range of mode-mixities as expressed by a phase angle (ψ) which is a measure of the amount of shear loading at the crack tip. A desired phase angle may be achieved by changing the moment-ratio (MR = Md/Ms)....

  12. Comparison of immersion density and improved microstructural characterization methods for measuring swelling in small irradiated disk specimens

    International Nuclear Information System (INIS)

    Sawai, T.; Suzuki, M.; Hishinuma, A.; Maziasz, P.J.

    1992-01-01

    The procedure of obtaining microstructural data from reactor-irradiated specimens has been carefully checked for accuracy by comparison of swelling data obtained from transmission electron microscopy (TEM) observations of cavities with density-change data measured using the Precision Densitometer at Oak Ridge National Laboratory (ORNL). Comparison of data measured by both methods on duplicate or, in some cases, on the same specimen has shown some appreciable discrepancies for US/Japan collaborative experiments irradiated in the High Flux Isotope Reactor (HFIR). The contamination spot separation (CSS) method was used in the past to determine the thickness of a TEM foil. Recent work has revealed an appreciable error in this method that can result in an overestimation of the foil thickness. This error causes lower swelling values to be measured by TEM microstructural observation relative to the Precision Densitometer. An improved method is proposed for determining the foil thickness by the CSS method, which includes a correction for the systematic overestimation of foil thickness. (orig.)

  13. Creep damage evaluation of low alloy steel weld joint by small punch creep testing

    International Nuclear Information System (INIS)

    Nishioka, Tomoya; Sawaragi, Yoshiatsu; Uemura, Hiromi

    2013-01-01

    The effect of sampling location on SPC (Small Punch Creep) tests were investigated for weld joints to establish evaluation method of Type IV creep behavior. The SPC specimen shape was 10mm diameter and 0.5mm thick round disc prepared from weld joints of 2.25Cr-1Mo low alloy steel. It was found that the center of SPC specimen should be 2mm apart from the weld interface as the recommended sampling location. Creep damage was imposed for large weld joint specimens by axial creep loading at 620degC, 52MPa with the interrupted time fraction of 0.34, 0.45, 0.64 and 0.82.SPC samples were prepared from those damaged specimens following the recommended way described in this paper. Among the various SPC tests conducted, good relationships were found for the test condition of 625degC, 200N. Namely, good relationships were obtained both between minimum deflection rate and creep life fraction, and between rupture time and creep life fraction. Consequently, creep life assessment of Type IV fracture by SPC tests could be well conducted using the sampling location and the test condition recommended in this paper. (author)

  14. Accelerated life tests of specimen heat pipe from Communication Technology Satellite (CTS) project

    Science.gov (United States)

    Tower, L. K.; Kaufman, W. B.

    1977-01-01

    A gas-loaded variable conductance heat pipe of stainless steel with methanol working fluid identical to one now on the CTS satellite was life tested in the laboratory at accelerated conditions for 14 200 hours, equivalent to about 70 000 hours at flight conditions. The noncondensible gas inventory increased about 20 percent over the original charge. The observed gas increase is estimated to increase operating temperature by about 2.2 C, insufficient to harm the electronic gear cooled by the heat pipes in the satellite. Tests of maximum heat input against evaporator elevation agree well with the manufacturer's predictions.

  15. Freeze-Thaw Cycle Test on Basalt, Diorite and Tuff Specimens with the Simulated Ground Temperature of Antarctica

    Science.gov (United States)

    Park, J.; Hyun, C.; Cho, H.; Park, H.

    2010-12-01

    Physical weathering caused by freeze-thaw action in cold regions was simulated with artificial weathering simulator in laboratory. Physical weathering of rock in cold regions usually depends on the temperature, rock type and moisture content. Then these three variables were considered in this study. The laboratory freeze-thaw tests were conducted on the three types of rocks, e.g. diorite, basalt and tuff, which are the major rock types around Sejong Station, King George Island, Antarctica. Nine core samples composed of three samples from each rock type were prepared in NX core, and 50 cycles of freeze-thaw test was carried out under dried and saturated water conditions. In this study, the physical weathering of rocks was investigated after each 10 cycles by measuring P-wave velocity, bulk density, effective porosity, Schmidt hardness and uniaxial compression strength(UCS). The experimental result of the diorite and the tuff specimens showed that P-wave velocity, bulk density, effective porosity, Schmidt hardness and UCS were gradually decreased as weathering progresses, but the result of the basalt specimens did not show typical trends due to the characteristics of irregular pore distribution and various pore sizes. Scanning electron microscopy(SEM) photographs of diorite, basalt and tuff specimens weathered in dried and saturated conditions were also acquired to investigate the role of water during physical weathering processes. The number and size of microcracks were increased as weathering progresses. This work was supported by the National Research Foundation of Korea(NRF) Grant(NRF-2010-0027753).

  16. Fatigue test results of flat plate specimens with surface cracks and evaluation of crack growth in structural components

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Yokoyama, Norio; Ohba, Toshihiro; Kawamura, Takaichi; Miyazono, Shohachiro

    1982-12-01

    Part-through surface cracks are most frequently observed in the inspection of structural components, and it is one of the important subjects in the assessment of safety to evaluate appropriately the growth of such cracks during the service life of structural components. Due to the complexity of the stress at the front free surface, the crack growth at the surface shows a different behavior from the other part. Besides, an effect of interaction is caused in the growth of multiple surface cracks. These effects should be included in the growth analysis of surface part-through cracks. Authors have carried out a series of fatigue tests on some kinds of pipes with multiple cracks in the inner surface, and subsequently the fatigue test of flat plate specimens, made of Type 304L stainless steel, with a single or double surface cracks was carried out to study the basic characteristics in the growth of multiple surface cracks. Based on the results of the flat plate test. the correction factors for the front free surface (Cs) and interaction (Ci) of surface cracks were derived quantitatively by the following empirical expressions; Cs = 0.824. Ci = (0.227(a/b) 2 (sec(PI X/2) - 1) + 1)sup(1/m). Using these two correction factors, a procedure to predict the growth of surface cracks was developed by applying the crack growth formula to both the thickness and surface directions. Besides, the crack growth predictions based on the procedure of ASME Code Sex. XI, and the above procedure without the correction of the free surface and interactions on the crack growth behaviors were compared with the test results of flat plate specimens. The crack growth behavior predicted by the procedure described in this report showed the best agreement with the test results in respects of the crack growth life and the change in the crack shape. The criteria of the ASME Code did not agree with the test results. (author)

  17. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Science.gov (United States)

    2010-01-01

    ... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as... current certification status of laboratories is available from the Division of Workplace Programs, Center... relationship with the licensee's or other entity's MRO(s) that may be construed as a potential conflict of...

  18. Model-Based Structural Health Monitoring of Fatigue Damage Test-Bed Specimens

    Science.gov (United States)

    2011-11-15

    the hull welds or notches along component edges are good initial candidates for the hypothetical damage initiation areas. The branching process adds...to it off-center. The base plate and the stiffener plate are rigidly welded by a tungsten inert gas ( TIG ) weld . Three different crack paths...shown in Figure 9(a), an 18 in long stiffener plate has been welded to each of the tested plates with 0.625 in long discrete TIG welds at 5 locations

  19. Comparing Repaired and Undamaged Specimens Test Results of Post-Tensioned Beam to Column Connections

    OpenAIRE

    Mustafa Kaya

    2015-01-01

    Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at 6% drift at these connections. As a result of the extra loads applied, little d...

  20. Preparation and observation of an artifact-free Ge2Sb2Te5 TEM specimen by the small angle cleavage technique

    International Nuclear Information System (INIS)

    Kim, M.S.; Kim, H.G.

    2006-01-01

    The amorphous Ge 2 Sb 2 Te 5 thin film for the application to the non-volatile memory device was prepared by the pulsed laser deposition on a SiO2/Si substrate. The amorphous Ge 2 Sb 2 Te 5 which has the T C around 150 deg. C is readily crystallized when exposed to a comparable heat such as the Ar beam irradiation during the conventional ion milling process. Retaining its amorphous initial phase is important in order to precisely observe and understand the crystallization behaviour whether it be the sample for a pure materialistic research or applied into the device. To avoid such deterioration of the film's amorphous nature, the complete mechanical TEM specimen preparation which is called the small angle cleavage technique (SACT) was adopted to show thermally undisturbed, an artifact-free amorphous Ge 2 Sb 2 Te 5 TEM specimen. The two distinctive amorphous and crystalline phases has been observed by the HRTEM study

  1. Contribution to the explanation of the spalling of small specimen without any mechanical restraint exposed to high temperature

    International Nuclear Information System (INIS)

    Morais, Marcus V.G. de; Pliya, Prosper; Noumowe, Albert; Beaucour, Anne-Lise; Ortola, Sophie

    2010-01-01

    The behaviour of concrete subjected to high temperature is studied. The aim of the study is to explain the spalling or bursting phenomenon observed during experimental studies in the laboratory. Mechanical computations are carried out with the finite element code CAST3M developed at the French Atomic Energy Agency (CEA). Heat gradient and water vapour pressure inside the concrete element are determined by using a thermo-hydrous model. Then, the mechanical stresses generated in the studied concrete element are calculated according to two behaviour assumptions: the linear isotropic elastic law and an elastoplastic model. Numerical simulations show that, during the heating cycles, tension stresses are developed in the central part and compression stresses at the surface of the cylindrical concrete element. The highest stresses appear when the surface temperature of the concrete element is about 300 o C. The tension stresses in the specimens then exceed the concrete tensile strength.

  2. Contribution to the explanation of the spalling of small specimen without any mechanical restraint exposed to high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Marcus V.G. de, E-mail: mvmorais@unb.b [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France); Pliya, Prosper [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France); Noumowe, Albert, E-mail: Albert.Noumowe@u-cergy.f [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France); Beaucour, Anne-Lise; Ortola, Sophie [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France)

    2010-10-15

    The behaviour of concrete subjected to high temperature is studied. The aim of the study is to explain the spalling or bursting phenomenon observed during experimental studies in the laboratory. Mechanical computations are carried out with the finite element code CAST3M developed at the French Atomic Energy Agency (CEA). Heat gradient and water vapour pressure inside the concrete element are determined by using a thermo-hydrous model. Then, the mechanical stresses generated in the studied concrete element are calculated according to two behaviour assumptions: the linear isotropic elastic law and an elastoplastic model. Numerical simulations show that, during the heating cycles, tension stresses are developed in the central part and compression stresses at the surface of the cylindrical concrete element. The highest stresses appear when the surface temperature of the concrete element is about 300 {sup o}C. The tension stresses in the specimens then exceed the concrete tensile strength.

  3. Ductile Tearing Resistance Indexing of Automotive Grade DP 590 Steel Sheets: EWF Testing Using DENT Specimens

    Science.gov (United States)

    Sahoo, Subhadra; Padmapriya, N.; De, Partha Sarathi; Chakraborti, P. C.; Ray, S. K.

    2018-03-01

    The essential work of fracture (EWF) method has been explored for indexing the ductile tearing resistance of DP 590 automotive grade dual-phase steel sheet both in longitudinal (L-T) and transverse (T-L) orientations. The simplest possible test and analysis procedures have been adopted. The EWF method is found to be eminently suitable for routine quality control and product development purposes for such materials. Areas for further research for improving the experimental strategy are highlighted. For the investigated steel sheet, the estimated tearing resistance is found to be distinctly higher for the L-T orientation compared to the T-L orientation; the reason thereof merits further investigation.

  4. Nanostructural evolution in surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Toyama, T.; Nagai, Y.; Tang, Z.; Hasegawa, M.; Almazouzi, A.; Walle, E. van; Gerard, R.

    2007-01-01

    The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of in-service commercial nuclear reactor pressure vessel steel welds of Doel-1 and Doel-2 are revealed by combining the three-dimensional local electrode atom probe and positron annihilation techniques. In both medium (0.13 wt.%) and high (0.30 wt.%) Cu welds, the CRNPs are found to form readily at the very beginning of the reactor lifetime. Thereafter, during the subsequent 30 years of operation, the residual Cu concentration in the matrix shows a slight decrease while the CRNPs coarsen. On the other hand, small vacancy clusters of V 3 -V 4 start appearing after the initial Cu precipitation and accumulate steadily with increasing neutron dose. The observed nanostructural evolution is shown to provide unique and fundamental information about the mechanisms of the irradiation-induced embrittlement of these specific materials

  5. Fracture assessment of HSST Plate 14 shallow-flaw cruciform bend specimens tested under biaxial loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bass, B.R.; McAfee, W.J.; Williams, P.T.; Pennell, W.E.

    1998-06-01

    A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow, surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a far-field, out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for an RPV material. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies, namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness; the conventional maximum principal stress criterion indicated no effect. A three-parameter Weibull model based on the hydrostatic stress criterion is shown to correlate the experimentally observed biaxial effect on cleavage fracture toughness by providing a scaling mechanism between uniaxial and biaxial loading states.

  6. Determination of the initiation of ductile tearing in cracked branch pipes on the basis of a pre-determined criterion using small specimens

    International Nuclear Information System (INIS)

    Chapuliot, S.; Marie, S.

    1999-01-01

    This article describes an experimental and numerical study of the initiation conditions of ductile tearing in ferritic materials. An initial criterion J i is determined experimentally using a sufficiently thick CT specimen. The numerical and experimental aspects are then discussed for thinner CT specimen and a method is proposed for determining it in thin test samples. The local ductile tear initiation criterion, which was determined on the basis of 3D finite element calculations, was applied to a cracked branch pipe geometry subjected to out-of-plane bending to compare the load estimates at the start of propagation and the values measured during the test. The results of the comparison were highly satisfactory: the criterion is predictive. (orig.)

  7. Numerical simulation of impact bend tests on araldite B and steel specimens

    International Nuclear Information System (INIS)

    Stoeckl, H.; Boehme, W.

    1983-09-01

    As a preliminary stage in the numerical simulation of impact bend tests on elastic-plastic sample materials some simpler experiments were calculated for this report, some of which occured without crack propagation, others with linear elastic crack propagation. These calculations were performed with an own program based on the method of finite differences and also with the finite element program ADINA. In the numerical models plane stress was assumed. Crack propagation was governed by a relation between crack velocity and stress intensity factor. As load input the measured hammer load was used in some cases, mass and initial velocity of the hammer in others. The sample looses contact to the anvils and to the hammer for some time, which had to be considered in model building. The stiffening of the model in the contact region caused by the discretization had to be compensated by springs inserted between the sample and the anvils. The simulation reproduces the experimentally observed behaviour of the sample quite well. Furthermore, additional information can be extracted from the experiment, e.g. concerning the partition of the impact energy. (orig.) [de

  8. Manufacturing method for intragranular stress corrosion cracking-induced test specimen for stainless steel pipeline

    International Nuclear Information System (INIS)

    Futagawa, Kiyoshi.

    1994-01-01

    In a manufacturing step for intragranular stress corrosion cracking-induced for stainless steel pipelines, pipe are abutted against with each other and welded, and a heat affected portion is applied with a sensitizing heat treatment. Further, a crevice jig is attached near the heat affected portion at the inner surface of the pipe and kept in a chlorine ion added water under high temperature and high pressure at a predetermined period of time. If tap water is used instead of purified water for C.P.T. test in a step of forming sample of IGSCC (intergranular stress corrosion cracking), since the chlorine ion concentration in the tap water is relatively high, TGSCC (intragranular stress corrosion crackings caused in all of the samples. A heat input and an interlayer temperature are determined for the material of stainless pipe having a carbon content of more than 0.05% so that the welding residual stress on the inner surface is applied as tension. The condition for the heat treatment is determined as, for example, 500degC x 24hr, and the samples are kept under water at high temperature and high pressure applied with chlorine ions for 500 to 200hours. As a result, since samples of TGSCC can be formed by utilizing the manufacturing step for IGSCC, there is no requirement for providing devices for applying environmental factors separately. (N.H.)

  9. Comparison of fracture toughness values from large-scale pipe system tests and C(T) specimens

    International Nuclear Information System (INIS)

    Olson, R.; Scott, P.; Marschall, C.; Wilkowski, G.

    1993-01-01

    Within the International Piping Integrity Research Group (IPIRG) program, pipe system experiments involving dynamic loading with intentionally circumferentially cracked pipe were conducted. The pipe system was fabricated from 406-mm (16-inch) diameter Schedule 100 pipe and the experiments were conducted at 15.5 MPa (2,250 psi) and 288 C (550 F). The loads consisted of pressure, dead-weight, thermal expansion, inertia, and dynamic anchor motion. Significant instrumentation was used to allow the material fracture resistance to be calculated from these large-scale experiments. A comparison of the toughness values from the stainless steel base metal pipe experiment of standard quasi-static and dynamic C(T) specimen tests showed the pipe toughness value was significantly lower than that obtained from C(T) specimens. It is hypothesized that the cyclic loading from inertial stresses in this pipe system experiment caused local degradation of the material toughness. Such effects are not considered in current LBB or pipe flaw evaluation criteria. 4 refs., 14 figs., 1 tab

  10. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  11. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    Science.gov (United States)

    Silva, F.; Sousa, S. P. B.; Arezes, P.; Swuste, P.; Ribeiro, M. C. S.; Baptista, J. S.

    2015-05-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.

  12. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    International Nuclear Information System (INIS)

    Silva, F; Sousa, S P B; Ribeiro, M C S; Arezes, P; Swuste, P; Baptista, J S

    2015-01-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health and Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field. (paper)

  13. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Investigation of the influence of different surface regularization methods for cylindrical concrete specimens in axial compression tests

    Directory of Open Access Journals (Sweden)

    R. MEDEIROS

    Full Text Available ABSTRACT This study was conducted with the aim of evaluating the influence of different methods for end surface preparation of compressive strength test specimens. Four different methods were compared: a mechanical wear method through grinding using a diamond wheel established by NBR 5738; a mechanical wear method using a diamond saw which is established by NM 77; an unbonded system using neoprene pads in metal retainer rings established by C1231 and a bonded capping method with sulfur mortar established by NBR 5738 and by NM 77. To develop this research, 4 concrete mixes were determined with different strength levels, 2 of group 1 and 2 of group 2 strength levels established by NBR 8953. Group 1 consists of classes C20 to C50, 5 in 5MPa, also known as normal strength concrete. Group 2 is comprised of class C55, C60 to C100, 10 in 10 MPa, also known as high strength concrete. Compression tests were carried out at 7 and 28 days for the 4 surface preparation methods. The results of this study indicate that the method established by NBR 5738 is the most effective among the 4 strengths considered, once it presents lower dispersion of values obtained from the tests, measured by the coefficient of variation and, in almost all cases, it demonstrates the highest mean of rupture test. The method described by NBR 5738 achieved the expected strength level in all tests.

  15. Plane strain fracture toughness tests on 2.4 and 3.9-inch-thick maraging steel specimens at various yield strength levels.

    Science.gov (United States)

    Fisher, D. M.; Repko, A. J.

    1972-01-01

    Tests of bend and compact specimens were conducted according to ASTM Tentative Method E 399-70T on a 200 grade maraging steel over a range of yield strengths from 123 to 234 ksi. The toughness of any given yield strength level was greater for the overaged condition than for the underaged. Some results which met the specimen size requirements of the method were distinctly lower than corresponding results from larger specimens. Inconsistencies in both validation and invalidation of results by the requirement for linearity of the test record were also noted.

  16. AGR steel corrosion monitoring schemes: progress on off-site testing of coupon specimens to end of 1985: Pt. 1

    International Nuclear Information System (INIS)

    Whittle, I.; Meredith, M.E.

    1988-03-01

    Off-site Advanced Gas-cooled Reactor steel corrosion monitoring through experiments on mild steel coupon specimens is reported. The appearance of all mild steel coupons oxidised over the temperature range 375 to 450 0 C is consistent with what is expected for the appropriate silicon content, temperature and in the gas mixes used. Likewise, weight gain data from the tests is as expected and where linear (breakaway) oxidation kinetics are in evidence, measured rates are within one standard deviation of the mean oxidation rates predicted by the 1/R model. Also, data relating mean breakaway oxide thickness to weight gain is in good agreement with the currently recommended relationship of 1 mg cm -2 weight gain = 6.72 μm oxide thickness. The observed oxidation behaviour of the off-site mild steel coupons is consistent with the most recent design data. (author)

  17. Vibration tests and analyses of the reactor building model on a small scale

    International Nuclear Information System (INIS)

    Tsuchiya, Hideo; Tanaka, Mitsuru; Ogihara, Yukio; Moriyama, Ken-ichi; Nakayama, Masaaki

    1985-01-01

    The purpose of this paper is to describe the vibration tests and the simulation analyses of the reactor building model on a small scale. The model vibration tests were performed to investigate the vibrational characteristics of the combined super-structure and to verify the computor code based on Dr. H. Tajimi's Thin Layered Element Theory, using the uniaxial shaking table (60 cm x 60 cm). The specimens consist of ground model, three structural model (prestressed concrete containment vessel, inner concrete structure, and enclosure building), a combined structural model and a combined structure-soil interaction model. These models are made of silicon-rubber, and they have a scale of 1:600. Harmonic step by step excitation of 40 gals was performed to investigate the vibrational characteristics for each structural model. The responses of the specimen to harmonic excitation were measured by optical displacement meters, and analyzed by a real time spectrum analyzer. The resonance and phase lag curves of the specimens to the shaking table were obtained respectively. As for the tests of a combined structure-soil interaction model, three predominant frequencies were observed in the resonance curves. These values were in good agreement with the analytical transfer function curves on the computer code. From the vibration tests and the simulation analyses, the silicon-rubber model test is useful for the fundamental study of structural problems. The computer code based on the Thin Element Theory can simulate well the test results. (Kobozono, M.)

  18. Small-Scale Shock Testing of Propellants and Ingredients

    National Research Council Canada - National Science Library

    Dawley, S

    2004-01-01

    .... The use of small-scale gap testing to evaluate the shock sensitivity of individual propellant ingredients and propellant formulations is a valuable method for experimentally establishing shock...

  19. CRC Test Ever - Small Area Estimates

    Science.gov (United States)

    For the ever had colorectal cancer test, a person 50 years of age or older must have reported having at least one colorectal endoscopy (sigmoidoscopy or colonoscopy) in his/her life or at least one home-based FOBT within the past two years by the time of interview.

  20. The covariant form of Maxwell equations for the fast simulation of the eddy current non destructive testing of complex specimens

    International Nuclear Information System (INIS)

    Caire, Francois

    2014-01-01

    This PhD work concerns the development of fast numerical tools, dedicated to the computation of the electromagnetic interaction between a low frequency 3D current source and a complex conductor, presenting rough interfaces and/or conductivity variations. The main application concerns the simulation of the Eddy Current nondestructive testing process applied to complex specimens. Indeed, the semi-analytical models available today are restricted to canonical geometries. The proposed method is based on the covariant form of Maxwell's equations, which translates the physical equations and relationships in a non-orthogonal coordinate system depending on the geometry of the specimen. Historically, this method (Curvilinear Coordinate Method, CCM or C-method) has been developed in the framework of optical applications, particularly for the characterization of diffraction gratings. Here, we transpose this formalism into the quasi-static regime and we extend the Second Order Vector Potential formalism, initially dedicated to orthonormal curvilinear coordinates systems, to general curvilinear coordinate systems. Thanks to this change of base, we are able to determine numerically a set of modal solutions of the source-free Maxwell equations in the new coordinate system introduced, and this allows us to represent the unknown fields as modal expansions in source-free domains. Then, the coefficients of these expansions are computed by introducing the source fields and by enforcing the boundary conditions that the total fields must verify at interfaces between the different media. In order to tackle the case of a layered conductor presenting rough interfaces, the generalized SOVP formalism is coupled with a recursive routine called the S-matrix algorithm. On the other hand, the application case of a complex shape specimen with depth-varying physical properties is treated by coupling the modal method we developed with a high-order numerical method: pseudo-spectral method. The

  1. Analytic performance studies and clinical reproducibility of a real-time PCR assay for the detection of epidermal growth factor receptor gene mutations in formalin-fixed paraffin-embedded tissue specimens of non-small cell lung cancer

    International Nuclear Information System (INIS)

    O’Donnell, Patrick; Shieh, Felice; Wei, Wen; Lawrence, H Jeffrey; Wu, Lin; Schilling, Robert; Bloom, Kenneth; Maltzman, Warren; Anderson, Steven; Soviero, Stephen; Ferguson, Jane; Shyu, Johnny; Current, Robert; Rehage, Taraneh; Tsai, Julie; Christensen, Mari; Tran, Ha Bich; Chien, Sean Shih-Chang

    2013-01-01

    Epidermal growth factor receptor (EGFR) gene mutations identify patients with non-small cell lung cancer (NSCLC) who have a high likelihood of benefiting from treatment with anti-EGFR tyrosine kinase inhibitors. Sanger sequencing is widely used for mutation detection but can be technically challenging, resulting in longer turn-around-time, with limited sensitivity for low levels of mutations. This manuscript details the technical performance verification studies and external clinical reproducibility studies of the cobas EGFR Mutation Test, a rapid multiplex real-time PCR assay designed to detect 41 mutations in exons 18, 19, 20 and 21. The assay’s limit of detection was determined using 25 formalin-fixed paraffin-embedded tissue (FFPET)-derived and plasmid DNA blends. Assay performance for a panel of 201 specimens was compared against Sanger sequencing with resolution of discordant specimens by quantitative massively parallel pyrosequencing (MPP). Internal and external reproducibility was assessed using specimens tested in duplicate by different operators, using different reagent lots, instruments and at different sites. The effects on the performance of the cobas EGFR test of endogenous substances and nine therapeutic drugs were evaluated in ten FFPET specimens. Other tests included an evaluation of the effects of necrosis, micro-organisms and homologous DNA sequences on assay performance, and the inclusivity of the assay for less frequent mutations. A >95% hit rate was obtained in blends with >5% mutant alleles, as determined by MPP analysis, at a total DNA input of 150 ng. The overall percent agreement between Sanger sequencing and the cobas test was 96.7% (negative percent agreement 97.5%; positive percent agreement 95.8%). Assay repeatability was 98% when tested with two operators, instruments, and reagent lots. In the external reproducibility study, the agreement was > 99% across all sites, all operators and all reagent lots for 11/12 tumors tested. Test

  2. Small UAS Test Area at NASA's Dryden Flight Research Center

    Science.gov (United States)

    Bauer, Jeffrey T.

    2008-01-01

    This viewgraph presentation reviews the areas that Dryden Flight Research Center has set up for testing small Unmanned Aerial Systems (UAS). It also reviews the requirements and process to use an area for UAS test.

  3. Environmental charging of spacecraft-tests of thermal control materials for use on the global positioning system flight space vehicle. Part 2: Specimen 6 to 9

    Science.gov (United States)

    Stevens, N. J.; Berkopec, F. D.; Blech, R. A.

    1976-01-01

    The NASA/USAF program on the Environmental Charging of Spacecraft Surfaces consists, in part, of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets of the type to be used on the Global Positioning System Flight Space Vehicles were tested to determine their response to electron flux. The primary result observed was that no discharges were obtained with the quartz-fiber-fabric-covered multilayer insulation specimen. The taped aluminized polyester grounding system used on all specimens did not appear to grossly deteriorate with time; however, the specimens require specific external pressure to maintain constant grounding system resistance.

  4. Experimental and Computational Study of Ductile Fracture in Small Punch Tests

    Directory of Open Access Journals (Sweden)

    Betül Gülçimen Çakan

    2017-10-01

    Full Text Available A unified experimental-computational study on ductile fracture initiation and propagation during small punch testing is presented. Tests are carried out at room temperature with unnotched disks of different thicknesses where large-scale yielding prevails. In thinner specimens, the fracture occurs with severe necking under membrane tension, whereas for thicker ones a through thickness shearing mode prevails changing the crack orientation relative to the loading direction. Computational studies involve finite element simulations using a shear modified Gurson-Tvergaard-Needleman porous plasticity model with an integral-type nonlocal formulation. The predicted punch load-displacement curves and deformed profiles are in good agreement with the experimental results.

  5. Experimental and Computational Study of Ductile Fracture in Small Punch Tests.

    Science.gov (United States)

    Gülçimen Çakan, Betül; Soyarslan, Celal; Bargmann, Swantje; Hähner, Peter

    2017-10-17

    A unified experimental-computational study on ductile fracture initiation and propagation during small punch testing is presented. Tests are carried out at room temperature with unnotched disks of different thicknesses where large-scale yielding prevails. In thinner specimens, the fracture occurs with severe necking under membrane tension, whereas for thicker ones a through thickness shearing mode prevails changing the crack orientation relative to the loading direction. Computational studies involve finite element simulations using a shear modified Gurson-Tvergaard-Needleman porous plasticity model with an integral-type nonlocal formulation. The predicted punch load-displacement curves and deformed profiles are in good agreement with the experimental results.

  6. δ18O of apatite phosphate in small pelagic fish: insights from wild-caught and tank-grown specimens

    Science.gov (United States)

    Lambert, T.; Javor, B.; Paytan, A.

    2011-12-01

    Oxygen isotope ratios of mineralized structures in fish reflect the temperature and isotopic composition of the water in which they grow. For bulk samples (e.g., whole scales, bones, and otoliths), understanding how this signal is integrated across time and space is critical, especially for organisms exposed to high variability in growth conditions. Here, we assess the response of fish scale δ18O (from apatite phosphate) to experimentally manipulated water conditions. Wild-caught sardines were grown at controlled temperatures (13°C, 17°C, and 21°C) for 11 months. Higher growth temperatures correlated to lower δ18O values, representing a combination of scale apatite deposited before and after the temperature manipulation. Models that account for both biomineral allometry and exposure to varying water properties (e.g., by overlaying migration routes, isoscapes, and temperature maps) have the potential to quantify the varying contributions of minerals grown under different conditions. We use this method to predict δ18O of apatite phosphate for small pelagic fish found in California coastal waters, then compare expected values to those obtained from collected samples. Since phosphate oxygen is relatively resistant to diagenesis, this modern calibration establishes a framework for paleo studies.

  7. Development of an evaluation method for fracture mechanical tests on small samples based on a cohesive zone model; Entwicklung einer Auswertemethode fuer bruchmechanische Versuche an kleinen Proben auf der Basis eines Kohaesivzonenmodells

    Energy Technology Data Exchange (ETDEWEB)

    Mahler, Michael

    2016-07-01

    The safety and reliability of nuclear power plants of the fourth generation is an important issue. It is based on a reliable interpretation of the components for which, among other fracture mechanical material properties are required. The existing irradiation in the power plants significantly affects the material properties which therefore need to be determined on irradiated material. Often only small amounts of irradiated material are available for characterization. In that case it is not possible to manufacture sufficiently large specimens, which are necessary for fracture mechanical testing in agreement with the standard. Small specimens must be used. From this follows the idea of this study, in which the fracture toughness can be predicted with the developed method based on tests of small specimens. For this purpose, the fracture process including the crack growth is described with a continuum mechanical approach using the finite element method and the cohesive zone model. The experiments on small specimens are used for parameter identification of the cohesive zone model. The two parameters of the cohesive zone model are determined by tensile tests on notched specimens (cohesive stress) and by parameter fitting to the fracture behavior of smalls specimens (cohesive energy). To account the different triaxialities of the specimens, the cohesive stress is used depending on the triaxiality. After parameter identification a large specimen can be simulated with the cohesive zone parameters derived from small specimens. The predicted fracture toughness of this big specimen fulfills the size requirements in the standard (ASTM E1820 or ASTM E399) in contrast to the small specimen. This method can be used for ductile and brittle material behavior and was validated in this work. In summary, this method offers the possibility to determine the fracture toughness indirectly based on small specimen testing. Main advantage is the low required specimen volume. Thereby massively

  8. Computed Tomography-Guided Core-Needle Biopsy Specimens Demonstrate Epidermal Growth Factor Receptor Mutations in Patients with Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Chen, C.M.; Chang, J.W.C.; Cheung, Y.C.; Lin, G.; Hsieh, J.J.; Hsu, T.; Huang, S.F.

    2008-01-01

    Background: Target therapy with a new class of epidermal growth factor receptor (EGFR) inhibitors shows improved clinical response in EGFR gene-mutated lung cancers. Purpose: To evaluate the use of computed tomography (CT)-guided core-needle biopsy specimens for the assessment of EGFR gene mutation in non-small-cell lung cancer (NSCLC). Material and Methods: Seventeen (nine males, eight females) patients with advanced NSCLC were enrolled in this study. All patients underwent CT-guided core-needle biopsy of the lung tumor prior to treatment with the EGFR inhibitor gefitinib. There were no life-threatening complications of biopsy. The specimens were sent fresh-frozen for EGFR mutation analysis and histopathological study. Results: There were 12 (70.6%) EGFR gene mutants and five (29.4%) nonmutants. The objective response rate to gefitinib therapy was 73.3% (11 of 15 patients), with 91.7% (11 of 12 mutants) for the mutant group and 0% for the nonmutant group. Conclusion: CT-guided core-needle biopsy of advanced NSCLC enables the acquisition of sufficient tissue for EGFR gene mutation analysis

  9. Recommended practice for small punch (SP) testing of metallic materials (draft)

    International Nuclear Information System (INIS)

    Takahashi, Hideaki; Shoji, Tetsuo; Mao, Xinyuan

    1988-09-01

    This practice covers the determination of fracture toughness characteristics of metallic materials such as ductile to brittle transition temperature (SPDBTT) and elastic-plastic fracture toughness (J ICSP ) using miniature small punch (SP) specimens. Three kinds of specimens with different shape; 10 by 10 by 0.5 mm, 10 by 10 by 0.25 mm and φ3 by 0.25 mm, are selected as the standard SP specimens. Two types of fixture shall be respectively used for the 10 and φ3 specimens. The relationship between load and deflection during buldge tests shall be recorded from low to high temperatures. Following two parameters in relation to fracture toughness are obtained from analyses of load-deflection curves: (1) The SP energy is calculated from the area surrounded with load-deflection curves, which corresponds to the total energy consumed up to the fracture. (2) The equivalent fracture strain (ε-bar qf ) is calculated from the maximum deflection at fracture (δ*). The SPDBTT can be derived from temperature dependence of SP energy, and the J ICSP can be estimated from the rational correlation curve between ε-bar qf and J IC . (author)

  10. Technology development on production of test specimens from irradiated capsule outer-tube and mechanical evaluation test of stainless steel with high dose carried out by the technology

    International Nuclear Information System (INIS)

    Hayashi, Koji; Shibata, Akira; Iwamatsu, Shigemi; Sozawa, Shizuo; Takada, Fumiki; Ohmi, Masao; Nakagawa, Tetsuya

    2008-03-01

    The irradiation capsule 74M-52J was irradiated during total 136 cycles at reactor core of JMTR and the maximum neutron dose reached on 3.9x10 26 n/m 2 at the capsule outer-tube made of a type 304 stainless steel. In order to produce mechanical test specimens from the outer-tube, a punching technique was developed as a simple remote-handling method in a hot-cell. From comparison between the punching and the mechanical cutting methods, it was clarified that the punching technique was applicable to practical use. Moreover, an evaluation test of mechanical properties using specimens sampled from the 74M-52 was performed with in-water high temperature condition, less than 288degC. The result shows that the residual elongation is 18% at 150degC and 13% at 288degC. It was confirmed that the type 304 stainless steel irradiated up to such high dose shows enough ductility. (author)

  11. Analysis of surface roughening behavior of 6063 aluminum alloy by tensile testing of a trapezoidal uniaxial specimen

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yang [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); Wang, Xiaosong, E-mail: hitxswang@hit.edu.cn [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); National Key Laboratory of Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001 (China); Yuan, Shijian [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); National Key Laboratory of Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001 (China)

    2016-08-30

    To determine the quantitative relationship between surface roughness and strain, the surface roughening behavior of a 6063 aluminum alloy tube was examined by tensile testing of a trapezoidal uniaxial specimen, that can provide a continuous strain distribution after tensile deformation. The surface roughness was measured using a laser scanning confocal microscope to reflect the degree of roughening. The microstructure and surface morphology were examined using electron back-scattered diffraction and in-situ scanning electron microscopy to determine the grain orientation and surface topography evolution. The surface roughness increased with strain when the strain was less than 0.067 and then decreased slightly, with a maximum surface roughness of 23.73 µm. Inhomogeneous deformation at the grain boundaries and inside the grains was enhanced with increasing strain, resulting in an increase of surface roughness when the strain was below a critical value. As the strain increased, a greater number of slip systems contributed to the further deformation. Thus, the strain became more homogeneous, and accordingly, the surface roughness slightly decreased.

  12. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG.

    Science.gov (United States)

    Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-09-01

    We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.

  13. Design and field tests of a modified small mammallivetrap

    African Journals Online (AJOL)

    -vinyl-chloride) and metal small mammal live-trap has been developed and subjected to field tests. The PVC traps captured greater numbers of very small rodents and shrews but fewer large rodents than did hardboard ones. s. Afr. J. Zool.

  14. Laboratory Test of Newton's Second Law for Small Accelerations

    International Nuclear Information System (INIS)

    Gundlach, J. H.; Schlamminger, S.; Spitzer, C. D.; Choi, K.-Y.; Woodahl, B. A.; Coy, J. J.; Fischbach, E.

    2007-01-01

    We have tested the proportionality of force and acceleration in Newton's second law, F=ma, in the limit of small forces and accelerations. Our tests reach well below the acceleration scales relevant to understanding several current astrophysical puzzles such as the flatness of galactic rotation curves, the Pioneer anomaly, and the Hubble acceleration. We find good agreement with Newton's second law at accelerations as small as 5x10 -14 m/s 2

  15. Small punch creep test: A promising methodology for high temperature plant components life evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tettamanti, S. [CISE SpA, Milan (Italy); Crudeli, R. [ENEL SpA, Milan (Italy)

    1998-12-31

    CISE and ENEL are involved for years in a miniaturization creep methodology project to obtain similar non-destructive test with the same standard creep test reliability. The goal can be reached with `Small punch creep test` that collect all the requested characteristics; quasi nondestructive disk specimens extracted both on external or internal side of components, than accurately machined and tested on little and cheap apparatus. CISE has developed complete creep small punch procedure that involved peculiar test facility and correlation`s law comparable with the more diffused isostress methodology for residual life evaluation on ex-serviced high temperature plant components. The aim of this work is to obtain a simple and immediately applicable relationship useful for plant maintenance managing. More added work is need to validate the Small Punch methodology and for relationship calibration on most diffusion high temperature structural materials. First obtained results on a comparative work on ASTM A355 P12 ex-serviced pipe material are presented joint with a description of the Small Punch apparatus realized in CISE. (orig.) 6 refs.

  16. Small punch creep test: A promising methodology for high temperature plant components life evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tettamanti, S [CISE SpA, Milan (Italy); Crudeli, R [ENEL SpA, Milan (Italy)

    1999-12-31

    CISE and ENEL are involved for years in a miniaturization creep methodology project to obtain similar non-destructive test with the same standard creep test reliability. The goal can be reached with `Small punch creep test` that collect all the requested characteristics; quasi nondestructive disk specimens extracted both on external or internal side of components, than accurately machined and tested on little and cheap apparatus. CISE has developed complete creep small punch procedure that involved peculiar test facility and correlation`s law comparable with the more diffused isostress methodology for residual life evaluation on ex-serviced high temperature plant components. The aim of this work is to obtain a simple and immediately applicable relationship useful for plant maintenance managing. More added work is need to validate the Small Punch methodology and for relationship calibration on most diffusion high temperature structural materials. First obtained results on a comparative work on ASTM A355 P12 ex-serviced pipe material are presented joint with a description of the Small Punch apparatus realized in CISE. (orig.) 6 refs.

  17. Determination of necking time in tensile test specimens, under high-temperature creep conditions, subjected to distribution of stresses over the cross-section

    Science.gov (United States)

    Lokoshchenko, A.; Teraud, W.

    2018-04-01

    The work describes an experimental research of creep of cylindrical tensile test specimens made of aluminum alloy D16T at a constant temperature of 400°C. The issue to be examined was the necking at different values of initial tensile stresses. The use of a developed noncontacting measuring system allowed us to see variations in the specimen shape and to estimate the true stress in various times. Based on the obtained experimental data, several criteria were proposed for describing the point of time at which the necking occurs (necking point). Calculations were carried out at various values of the parameters in these criteria. The relative interval of deformation time in which the test specimen is uniformly stretched was also determined.

  18. Fractographic examination of HT-9 and 9Cr-1Mo Charpy specimens irradiated in the AD-2 test

    International Nuclear Information System (INIS)

    Gelles, D.S.; Hu, W.L.

    1983-01-01

    Fracture surface topologies have been examined using scanning electron microscopy for 20 selected half sized Charpy impact specimens of HT-9 and Modified 9Cr-1Mo in order to provide improved understanding of fracture toughness degradation as a result of irradiation for Path E alloys. The specimen matrix included unirradiated specimens and specimens irradiated in EBR-II in the AD-2 experiment. Also, hardness measurements have been made on selected irradiated Charpy specimens. The results of examinations indicate that irradiation hardening due to G-phase formation at 390 0 C is responsible for the large shift in ductile-to-brittle transition temperature (DBTT) found in HT-9. Toughness degradation in HT-9 observed following higher temperature irradiations is attributed to precipitation at delta ferrite stringers. Reductions in toughness as a consequence of irradiation in Modified 9Cr-1Mo are attributed to in-reactor precipitation of (V,Nb)C and M 23 C 6 . It is shown that crack propagation rates for ductile and brittle failure modes can be measured, that they differ by over an order of magnitude and that unexpected multiple shifts in fracture mode from ductile to brittle failure can be attributed to the effect of delta ferrite stringers on crack propagation rates

  19. Specimen alignment in an axial tensile test of thin films using direct imaging and its influence on the mechanical properties of BeCu

    International Nuclear Information System (INIS)

    Kang, Dong-Joong; Park, Jun-Hyub; Shin, Myung-Soo; Ha, Jong-Eun; Lee, Hak-Joo

    2010-01-01

    This paper proposes a new system for verification of the alignment of loading fixtures and test specimens during tensile testing of thin film with a micrometer size through direct imaging. The novel and reliable image recognition system to evaluate the misalignment between the load train and the specimen axes during tensile test of thin film was developed using digital image processing technology with CCD. The decision of whether alignment of the tensile specimen is acceptable or not is based on a probabilistic analysis through the edge feature extraction of digital imaging. In order to verify the performance of the proposed system and investigate the effect of the misalignment of the specimen on tensile properties, the tensile tests were performed as displacement control in air and at room temperature for metal thin film, the beryllium copper (BeCu) alloys. In the case of the metal thin films, bending stresses caused by misalignment are insignificant because the films are easily bent during tensile tests to eliminate the bending stresses. And it was observed that little effects and scatters on tensile properties occur by stress gradient caused by twisting at in-plane misalignment, and the effects and scatters on tensile properties are insignificant at out-of-plane misalignment, in the case of the BeCu thin film.

  20. Testing of elastomer seals using small-size rigs

    International Nuclear Information System (INIS)

    Leeks, C.W.E.; Dunford, B.; Barnfield, J.H.; Gray, I.L.S.

    1997-01-01

    This paper looks at the use of small size seal leakage test rigs to demonstrate the compliance of full size container seals against the IAEA Transport Regulation's limits for activity release for normal transport and accident conditions. The detailed requirements of the regulations are discussed and it is concluded that an appropriate test programme to meet these requirements using only small size test rigs, can normally be set up and carried out on a relatively short time scale. It is important that any small test rigs should be designed to represent the relevant features of the seal arrangement and the overall test programme should cover all of the conditions, specified by the regulations, for the type, classification and contents of the container under consideration. The parameters of elastomer O-rings, which affect their sealing ability, are considered and those which are amenable to small scale testing or have to be modelled at full size are identified. Generally, the seals used in leakage tests have to be modelled with a full size cross-section but can have a reduced peripheral length. (Author)

  1. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (12.5 mm diam by 4.6 mm thick). Both unloading compliance and potential drop methods have been used to monitor crack extension during the J-integral resistance (J-R) curve testing. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hat cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimens 12.7-mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  2. qPCR-High resolution melt analysis for drug susceptibility testing of Mycobacterium leprae directly from clinical specimens of leprosy patients.

    Science.gov (United States)

    Araujo, Sergio; Goulart, Luiz Ricardo; Truman, Richard W; Goulart, Isabela Maria B; Vissa, Varalakshmi; Li, Wei; Matsuoka, Masanori; Suffys, Philip; Fontes, Amanda B; Rosa, Patricia S; Scollard, David M; Williams, Diana L

    2017-06-01

    Real-Time PCR-High Resolution Melting (qPCR-HRM) analysis has been recently described for rapid drug susceptibility testing (DST) of Mycobacterium leprae. The purpose of the current study was to further evaluate the validity, reliability, and accuracy of this assay for M. leprae DST in clinical specimens. The specificity and sensitivity for determining the presence and susceptibility of M. leprae to dapsone based on the folP1 drug resistance determining region (DRDR), rifampin (rpoB DRDR) and ofloxacin (gyrA DRDR) was evaluated using 211 clinical specimens from leprosy patients, including 156 multibacillary (MB) and 55 paucibacillary (PB) cases. When comparing the results of qPCR-HRM DST and PCR/direct DNA sequencing, 100% concordance was obtained. The effects of in-house phenol/chloroform extraction versus column-based DNA purification protocols, and that of storage and fixation protocols of specimens for qPCR-HRM DST, were also evaluated. qPCR-HRM results for all DRDR gene assays (folP1, rpoB, and gyrA) were obtained from both MB (154/156; 98.7%) and PB (35/55; 63.3%) patients. All PCR negative specimens were from patients with low numbers of bacilli enumerated by an M. leprae-specific qPCR. We observed that frozen and formalin-fixed paraffin embedded (FFPE) tissues or archival Fite's stained slides were suitable for HRM analysis. Among 20 mycobacterial and other skin bacterial species tested, only M. lepromatosis, highly related to M. leprae, generated amplicons in the qPCR-HRM DST assay for folP1 and rpoB DRDR targets. Both DNA purification protocols tested were efficient in recovering DNA suitable for HRM analysis. However, 3% of clinical specimens purified using the phenol/chloroform DNA purification protocol gave false drug resistant data. DNA obtained from freshly frozen (n = 172), formalin-fixed paraffin embedded (FFPE) tissues (n = 36) or archival Fite's stained slides (n = 3) were suitable for qPCR-HRM DST analysis. The HRM-based assay was also able to

  3. Corrosion Characteristics of Inconel-600 at the NP(Cu)-HYBRID Decontamination Demonstration Test with HANARO FTL Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jun Young; Park, Sang Yoon; Won, Hui Jun; Kim, Seon Byeong; Choi, Wang Kyu; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    An alkaline permanganate (AP) or nitric permanganate (NP) oxidative phase has been generally used to dissolve the chromium-rich oxide. AP is advantageous for the corrosion resistance, but increases the volume of secondary waste during the decontamination procedure. On the other hand, NP has a high corrosion rate but reduces secondary waste. For the safe use of an oxidative decontamination solution with high corrosive resistance and less amount of secondary waste are required. In this study, we modified NP oxidative decontamination solution by adding Cu{sup 2+} to reduce the corrosion rate. To evaluate the general corrosion characteristics, we measured the weight losses of selected specimens in an NP(Cu) and other solutions. The localized corrosion was observed using an optical microscope (OM). To compare the decontamination performance, we measured the contact dose rate of specimens treated in NP-HYBRID and NP(Cu)-HYBRID systems. The reduced corrosion characteristics of the Inconel-600 specimen in a NP(Cu) oxidative solution was observed in terms of generalized corrosion as well as localized corrosion. Less corrosion characteristics do not affect the performance of the overall decontamination compared to the NP-HYBRID process. Therefore, our results support that the NP(Cu)-HYBRID decontamination process is appropriate for the decontamination of the primary coolant system in a nuclear reactor.

  4. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods are necessary to facilitate the fracture toughness testing of small disk compact specimens of irradiated candidate materials for first-wall fusion applications. New methods have been developed for both the unloading compliance and potential drop techniques of monitoring crack growth. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hot cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimen 12.7 mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  5. Test of the law of gravitation at small accelerations

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, H. [Wuppertal Univ. (Germany); Lohrmann, E.; Schubert, S. [Hamburg Univ. (Germany). Inst. fuer Experimentalphysik; Bartel, W.; Glazov, A.; Loehr, B.; Niebuhr, C.; Wuensch, E. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Joensson, L.; Kempf, G. [Lund Univ. (Sweden)

    2011-12-15

    Newton's Law of Gravitation has been tested at small values a of the acceleration, down to a {approx}10{sup -10} ms{sup -2}, the approximate value of MOND's constant a{sub 0}. No deviations were found. (orig.)

  6. Lessons from Small-scale Standardised Testing of English Reading ...

    African Journals Online (AJOL)

    The superior performance by the public school can partly be explained by teachers teaching experience, most of them have been teaching for more than ten years and greater community support for the school. It is recommended that data produced through small-scale standardised testing should be used by school ...

  7. Recent developments in small punch testing: Applications at elevated temperatures

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr

    2016-01-01

    Roč. 86, DEC (2016), s. 25-33 ISSN 0167-8442 R&D Projects: GA MŠk(CZ) LQ1601 Institutional support: RVO:68081723 Keywords : Small punch test * Creep rupture * Stress relaxation Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.659, year: 2016

  8. Genomic characterisation of small cell lung cancer patient-derived xenografts generated from endobronchial ultrasound-guided transbronchial needle aspiration specimens.

    Directory of Open Access Journals (Sweden)

    Tracy L Leong

    Full Text Available Patient-derived xenograft (PDX models generated from surgical specimens are gaining popularity as preclinical models of cancer. However, establishment of PDX lines from small cell lung cancer (SCLC patients is difficult due to very limited amount of available biopsy material. We asked whether SCLC cells obtained from endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA could generate PDX lines that maintained the phenotypic and genetic characteristics of the primary tumor. Following successful EBUS-TBNA sampling for diagnostic purposes, we obtained an extra sample for cytologic analysis and implantation into the flanks of immunodeficient mice. Animals were monitored for engraftment for up to 6 months. Histopathologic and immunohistochemical analysis, and targeted next-generation re-sequencing, were then performed in both the primary sample and the derivative PDX line. A total of 12 patients were enrolled in the study. EBUS-TBNA aspirates yielded large numbers of viable tumor cells sufficient to inject between 18,750 and 1,487,000 cells per flank, and to yield microgram quantities of high-quality DNA. Of these, samples from 10 patients generated xenografts (engraftment rate 83% with a mean latency of 104 days (range 63-188. All but one maintained a typical SCLC phenotype that closely matched the original sample. Identical mutations that are characteristic of SCLC were identified in both the primary sample and xenograft line. EBUS-TBNA has the potential to be a powerful tool in the development of new targeting strategies for SCLC patients by providing large numbers of viable tumor cells suitable for both xenografting and complex genomic analysis.

  9. A creep life assessment method for boiler pipes using small punch creep test

    International Nuclear Information System (INIS)

    Izaki, Toru; Kobayashi, Toshimi; Kusumoto, Junichi; Kanaya, Akihiro

    2009-01-01

    The small punch creep (SPC) test is considered as a highly useful method for creep life assessment for high temperature plant components. SPC uses miniature-sized specimens and does not cause any serious sampling damages, and its assessment accuracy is at a high level. However, in applying the SPC test to the residual creep life assessment of the boiler in service, there are some issues to be studied. In order to apply SPC test to the residual creep life assessment of the 2.25Cr-1Mo steel boiler pipe, the relationship between uniaxial creep stress and the SPC test load has been studied. The virgin material, pre-crept, weldment and service aged samples of 2.25Cr-1Mo steel were tested. It was confirmed that the relationship between uniaxial creep stress and the SPC test load at the same rupture time can be described as a single straight line independent of test conditions and materials. Therefore a life assessment is possible by using SPC test in place of uniaxial creep tests. The creep life assessment using SPC was applied to actual thermal power plant components which are in service.

  10. Small passenger car transmission test-Chevrolet 200 transmission

    Science.gov (United States)

    Bujold, M. P.

    1980-01-01

    The small passenger car transmission was tested to supply electric vehicle manufacturers with technical information regarding the performance of commerically available transmissions which would enable them to design a more energy efficient vehicle. With this information the manufacturers could estimate vehicle driving range as well as speed and torque requirements for specific road load performance characteristics. A 1979 Chevrolet Model 200 automatic transmission was tested per a passenger car automatic transmission test code (SAE J651b) which required drive performance, coast performance, and no load test conditions. The transmission attained maximum efficiencies in the mid-eighty percent range for both drive performance tests and coast performance tests. Torque, speed and efficiency curves map the complete performance characteristics for Chevrolet Model 200 transmission.

  11. Quench tests of Nb3Al small racetrack magnets

    International Nuclear Information System (INIS)

    Yamada, R.; Kikuchi, A.; Tartaglia, Michael Albert; Ambrosio, G.; Andreev, N.; Barzi, E.; Carcagno, R.; Feher, S.; Kashikhin, V.V.; Kotelnikov, S.; Lamm, Michael J.; Fermilab; NIMC, Tsukuba; KEK, Tsukuba

    2007-01-01

    Two Cu stabilized Nb3Al strands, F1 (Nb matrixed) and F3 (Ta matrixed), have been made at NIMS and their Rutherford cables were made at Fermilab in collaboration with NIMS. A Small Race-track magnet using F1 Rutherford cable, the first Nb3Al dipole magnet in the world, was constructed and tested to full current at Fermilab. This magnet was tested extensively to full short sample data and its quench characteristics were studied and reported. The 3-D magnetic field calculation was done with ANSYS to find the peak field. The quench characteristics of the magnet are explained with the characteristics of the Nb3Al strand and Rutherford cable. The other Small Race-track magnet using Ta matrixed F3 strand was constructed and will be tested in the near future. The advantages and disadvantages of these Nb3Al cables are discussed

  12. Quench tests of Nb3Al small racetrack magnets

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, R.; Kikuchi, A.; Tartaglia, Michael Albert; Ambrosio, G.; Andreev, N.; Barzi, E.; Carcagno, R.; Feher, S.; Kashikhin, V.V.; Kotelnikov, S.; Lamm, Michael J.; /Fermilab /NIMC, Tsukuba /KEK, Tsukuba

    2007-08-01

    Two Cu stabilized Nb3Al strands, F1 (Nb matrixed) and F3 (Ta matrixed), have been made at NIMS and their Rutherford cables were made at Fermilab in collaboration with NIMS. A Small Race-track magnet using F1 Rutherford cable, the first Nb3Al dipole magnet in the world, was constructed and tested to full current at Fermilab. This magnet was tested extensively to full short sample data and its quench characteristics were studied and reported. The 3-D magnetic field calculation was done with ANSYS to find the peak field. The quench characteristics of the magnet are explained with the characteristics of the Nb3Al strand and Rutherford cable. The other Small Race-track magnet using Ta matrixed F3 strand was constructed and will be tested in the near future. The advantages and disadvantages of these Nb3Al cables are discussed.

  13. New Technique for Cryogenically Cooling Small Test Articles

    Science.gov (United States)

    Rodriquez, Karen M.; Henderson, Donald J.

    2011-01-01

    Convective heat removal techniques to rapidly cool small test articles to Earth-Moon L2 temperatures of 77 K were accomplished through the use of liquid nitrogen (LN2). By maintaining a selected pressure range on the saturation curve, test articles were cooled below the LN2 boiling point at ambient pressure in less than 30 min. Difficulties in achieving test pressures while maintaining the temperature tolerance necessitated a modification to the original system to include a closed loop conductive cold plate and cryogenic shroud

  14. A study on stress analysis of small punch-creep test and its experimental correlations with uniaxial-creep test

    International Nuclear Information System (INIS)

    Lee, Song In; Baek, Seoung Se; Kwon, Il Hyun; Yu, Hyo Sun

    2002-01-01

    A basic research was performed to ensure the usefulness of Small Punch-creep(SP-creep) test for residual life evaluation of heat resistant components effectively. This paper presents analytical results of initial stress and strain distributions in SP specimen caused by constant loading for SP-creep test and its experimental correlations with uniaxial creep(Ten-creep) test on 9CrlMoVNb steel. It was shown that the initial maximum equivalent stress, σ eq · max from FE analysis was correlated with steady-state equivalent creep strain rate, ε qf-ss , rupture time, t r , activation energy, Q and Larson-Miller parameter, LMP during SP-creep deformation. The simple correlation laws, σ SP - σ TEN , P SP -σ TEN and Q SP -Q TEN adopted to established a quantitative correlation between SP-creep and Ten-creep test data. Especially, the activation energy obtained from SP-creep test is linearly related to that from Ten-creep test at 650 deg. C as follows : Q SP-P =1.37 Q TEN , Q SP-σ =1.53 Q TEN

  15. Comparison of small n statistical tests of differential expression applied to microarrays

    Directory of Open Access Journals (Sweden)

    Lee Anna Y

    2009-02-01

    Full Text Available Abstract Background DNA microarrays provide data for genome wide patterns of expression between observation classes. Microarray studies often have small samples sizes, however, due to cost constraints or specimen availability. This can lead to poor random error estimates and inaccurate statistical tests of differential expression. We compare the performance of the standard t-test, fold change, and four small n statistical test methods designed to circumvent these problems. We report results of various normalization methods for empirical microarray data and of various random error models for simulated data. Results Three Empirical Bayes methods (CyberT, BRB, and limma t-statistics were the most effective statistical tests across simulated and both 2-colour cDNA and Affymetrix experimental data. The CyberT regularized t-statistic in particular was able to maintain expected false positive rates with simulated data showing high variances at low gene intensities, although at the cost of low true positive rates. The Local Pooled Error (LPE test introduced a bias that lowered false positive rates below theoretically expected values and had lower power relative to the top performers. The standard two-sample t-test and fold change were also found to be sub-optimal for detecting differentially expressed genes. The generalized log transformation was shown to be beneficial in improving results with certain data sets, in particular high variance cDNA data. Conclusion Pre-processing of data influences performance and the proper combination of pre-processing and statistical testing is necessary for obtaining the best results. All three Empirical Bayes methods assessed in our study are good choices for statistical tests for small n microarray studies for both Affymetrix and cDNA data. Choice of method for a particular study will depend on software and normalization preferences.

  16. Some mechanical properties of small specimens cut from 1.79-inch-thick southern pine dried for 6 hours at 300°F or for 5 days at 180°F- A Comparison

    Science.gov (United States)

    P. Koch; W.L. Wellford

    1978-01-01

    Small specimens cut from 1.79-inch-thick southern pine dried from green condition for 6 hours at a dry-bulb temperature of 300 F suffered no diminution in the mechanical properties determined, when compared to matched wood dried for 5 days at 180 F.

  17. Small Radioisotope Power System Testing at NASA Glenn Research Center

    Science.gov (United States)

    Dugala, Gina; Bell, Mark; Oriti, Salvatore; Fraeman, Martin; Frankford, David; Duven, Dennis

    2013-01-01

    In April 2009, NASA Glenn Research Center (GRC) formed an integrated product team (IPT) to develop a Small Radioisotope Power System (SRPS) utilizing a single Advanced Stirling Convertor (ASC) with passive balancer. A single ASC produces approximately 80 We making this system advantageous for small distributed lunar science stations. The IPT consists of Sunpower, Inc., to provide the single ASC with a passive balancer, The Johns Hopkins University Applied Physics Laboratory (JHUAPL) to design an engineering model Single Convertor Controller (SCC) for an ASC with a passive balancer, and NASA GRC to provide technical support to these tasks and to develop a simulated lunar lander test stand. The single ASC with a passive balancer, simulated lunar lander test stand, and SCC were delivered to GRC and were tested as a system. The testing sequence at GRC included SCC fault tolerance, integration, electromagnetic interference (EMI), vibration, and extended operation testing. The SCC fault tolerance test characterized the SCCs ability to handle various fault conditions, including high or low bus power consumption, total open load or short circuit, and replacing a failed SCC card while the backup maintains control of the ASC. The integrated test characterized the behavior of the system across a range of operating conditions, including variations in cold-end temperature and piston amplitude, including the emitted vibration to both the sensors on the lunar lander and the lunar surface. The EMI test characterized the AC and DC magnetic and electric fields emitted by the SCC and single ASC. The vibration test confirms the SCCs ability to control the single ASC during launch. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the ASC with a passive balancer and the SCC. This paper will discuss the results of each of these tests.

  18. Development of evaluation technique of high temperature creep characteristics by small punch-creep test method (I)

    International Nuclear Information System (INIS)

    Baek, Seung Se; Na, Sung Hun; Yu, Hyo Sun; Na, Eui Gyun

    2001-01-01

    In this study, a Small Punch Creep(SP-Creep) test using miniaturized specimen(10 x 10 x 0.5mm) is described to develop the new creep test method for high temperature structural materials. The SP-Creep test is applied to 2.25Cr-1Mo(STBA24) steel which is widely used as boiler tube material. The test temperatures applied for the creep deformation of miniaturized specimens are between 550∼600 .deg. C. The SP-Creep curves depend definitely on applied load and creep temperature, and show the three stages of creep behavior like in conventional uniaxial tensile creep curves. The load exponent of miniaturized specimen decrease with increasing test temperature, and its behavior is similar to stress exponent behavior of uniaxial creep test. The creep activation energy obtained from the relationship between SP-Creep rate and test temperature decreases as the applied load increases. A predicting equation of SP-Creep rate for 2.25Cr-1Mo steel is suggested, and a good agreement between experimental and calculated data has been found

  19. Application Anti Microbial Activity Test and Direct Inoculation of Urinary Specimen Test to Increase the Quality of Results and Decrease the Production Cost in Clinical Microbiology Laboratory, Sanglah General Hospital Hospital, Bali-Indonesia

    Directory of Open Access Journals (Sweden)

    Nyoman Sri-Budayanti

    2012-05-01

    Full Text Available Objective: Urinary tract infection (UTI is the most common bacterial infection in general practice and in hospitals. Fast and accurate urine culture and sensitivity test are needed for adequate therapy. Anti Microbial Activity test (AMA test that is used to detect the presence of antibiotics in urine specimens is not commonly used in clinical microbiology laboratories. Some laboratories are still using indirect inoculation technique using enriched media before inoculating onto the agar media. The aim of this research is to compare results of urinary examination of direct inoculation technique with AMA test with indirect inoculation technique without AMA test.Methods: A number of 210 urine specimens were collected in Clinical Microbiology Laboratory at Sanglah General Hospital within a time period between 16 June until 16 July 2009.Results: Antibiotics were detected in 40% of the urinary specimens; whereas 48.1% showed no evidence of UTI, that is negative AMA test and sterile urinary culture or colony growth < 105 CFU/ml. Only 11.9% of the specimens indicates urinary tract infections. The examination can be completed within 2-3 days which is shorter than indirect inoculation test which require 5-7 days. Direct inoculation technique can reduce the cost of production three-fold the costs require for an indirect inoculation test.Conclusions: Application of AMA test and direct inoculation technique can give results more rapidly, reliable and useful for clinicians. This also decrease the laboratory’s cost of production.

  20. Small-scale fixed wing airplane software verification flight test

    Science.gov (United States)

    Miller, Natasha R.

    The increased demand for micro Unmanned Air Vehicles (UAV) driven by military requirements, commercial use, and academia is creating a need for the ability to quickly and accurately conduct low Reynolds Number aircraft design. There exist several open source software programs that are free or inexpensive that can be used for large scale aircraft design, but few software programs target the realm of low Reynolds Number flight. XFLR5 is an open source, free to download, software program that attempts to take into consideration viscous effects that occur at low Reynolds Number in airfoil design, 3D wing design, and 3D airplane design. An off the shelf, remote control airplane was used as a test bed to model in XFLR5 and then compared to flight test collected data. Flight test focused on the stability modes of the 3D plane, specifically the phugoid mode. Design and execution of the flight tests were accomplished for the RC airplane using methodology from full scale military airplane test procedures. Results from flight test were not conclusive in determining the accuracy of the XFLR5 software program. There were several sources of uncertainty that did not allow for a full analysis of the flight test results. An off the shelf drone autopilot was used as a data collection device for flight testing. The precision and accuracy of the autopilot is unknown. Potential future work should investigate flight test methods for small scale UAV flight.

  1. The development of fuel pins and material specimens mixed loading irradiation test rig in the experimental fast reactor Joyo. The development of the fuel-material hybrid rig

    International Nuclear Information System (INIS)

    Oyamatsu, Yasuko; Someya, Hiroyuki

    2013-02-01

    In the experimental fast reactor Joyo, there were many tests using the irradiation rigs that it was possible to be set irradiation conditions for each compartment independently. In case of no alternative fuel element to irradiate after unloading the irradiated compartments, the irradiation test was restarted with the dummy compartment which the fuel elements was not mounted. If the material specimens are mounted in this space, it is possible to use the irradiation space effectively. For these reasons, the irradiation rig (hybrid rig) is developed that is consolidated with material specimens compartment and fuel elements compartment. Fuel elements and material specimens differ greatly with heat generation, so that the most important issue in developing of hybrid rig is being able to distribute appropriately the coolant flow which satisfies irradiation conditions. The following is described by this report. (1) It was confirmed that the flow distribution of loading the same irradiation rig with the compartment from which a flow demand differs could be satisfied. (2) It was confirmed that temperature setting range of hybrid rig could be equivalent to that of irradiation condition. (3) By standardizing the coolant entrance structure of the compartment lower part, the prospect which can perform easily recombination of the compartment from which a type differs between irradiation rigs was acquired. (author)

  2. Small female rib cage fracture in frontal sled tests.

    Science.gov (United States)

    Shaw, Greg; Lessley, David; Ash, Joseph; Poplin, Jerry; McMurry, Tim; Sochor, Mark; Crandall, Jeff

    2017-01-02

    The 2 objectives of this study are to (1) examine the rib and sternal fractures sustained by small stature elderly females in simulated frontal crashes and (2) determine how the findings are characterized by prior knowledge and field data. A test series was conducted to evaluate the response of 5 elderly (average age 76 years) female postmortem human subjects (PMHS), similar in mass and size to a 5th percentile female, in 30 km/h frontal sled tests. The subjects were restrained on a rigid planar seat by bilateral rigid knee bolsters, pelvic blocks, and a custom force-limited 3-point shoulder and lap belt. Posttest subject injury assessment included identifying rib cage fractures by means of a radiologist read of a posttest computed tomography (CT) and an autopsy. The data from a motion capture camera system were processed to provide chest deflection, defined as the movement of the sternum relative to the spine at the level of T8.  A complementary field data investigation involved querying the NASS-CDS database over the years 1997-2012. The targeted cases involved belted front seat small female passenger vehicle occupants over 40 years old who were injured in 25 to 35 km/h delta-V frontal crashes (11 to 1 o'clock). Peak upper shoulder belt tension averaged 1,970 N (SD = 140 N) in the sled tests. For all subjects, the peak x-axis deflection was recorded at the sternum with an average of -44.5 mm or 25% of chest depth. The thoracic injury severity based on the number and distribution of rib fractures yielded 4 subjects coded as Abbreviated Injury Scale (AIS) 3 (serious) and one as AIS 5 (critical). The NASS-CDS field data investigation of small females identified 205 occupants who met the search criteria. Rib fractures were reported for 2.7% of the female occupants. The small elderly test subjects sustained a higher number of rib cage fractures than expected in what was intended to be a minimally injurious frontal crash test condition. Neither field studies nor

  3. Safety and reliability of pressure components with special emphasis on the contribution of component and large specimen testing to structural integrity assessment methodology. Vol. 1 and 2

    International Nuclear Information System (INIS)

    1987-01-01

    The 51 papers of the 13. MPA-seminar contribute to structural integrity assessment methodology with special emphasis on the component and large specimen testing. 8 of the papers deal with fracture mechanics, 6 papers with dynamic loading, 13 papers with nondestructive testing, 2 papers with radiation embrittlement, 5 papers with pipe failure, 4 papers with components, 2 papers with thermal shock loading, 5 papers with the high temperature behaviour, 4 papers with the integrity of vessels and 3 papers with the integrity of welded joints. Especially also the fracture behaviour of steel material is verificated. All papers are separately indexed and analysed for the database. (DG) [de

  4. Numerical simulation of small scale soft impact tests

    International Nuclear Information System (INIS)

    Varpasuo, Pentti

    2008-01-01

    This paper describes the small scale soft missile impact tests. The purpose of the test program is to provide data for the calibration of the numerical simulation models for impact simulation. In the experiments, both dry and fluid filled missiles are used. The tests with fluid filled missiles investigate the release speed and the droplet size of the fluid release. This data is important in quantifying the fire hazard of flammable liquid after the release. The spray release velocity and droplet size are also input data for analytical and numerical simulation of the liquid spread in the impact. The behaviour of the impact target is the second investigative goal of the test program. The response of reinforced and pre-stressed concrete walls is studied with the aid of displacement and strain monitoring. (authors)

  5. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  6. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  7. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1994-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (1.25 mm diam by 4.6 mm thick). Specimens of European type 316L austenitic stainless steel were irradiated to damage levels of about 3 dpa at nominal irradiation temperatures of either 90 or 250 C and tested over a temperature range from 20 to 250 C. Results show that irradiation to this dose level at these temperatures reduces the fracture toughness but the toughness remains quite high. The toughness decreases as the test temperature increases. Irradiation at 250 C is more damaging than at 90 C, causing larger decreases in the fracture toughness. The testing shows that it is possible to generate useful fracture toughness data with a small disk compact specimens

  8. Replacement/Refurbishment of JSC/NASA POD Specimens

    Science.gov (United States)

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  9. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  10. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  11. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  12. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  13. On the correlation between minimum thickness and central deflection during small punch test

    International Nuclear Information System (INIS)

    Kumar, Pradeep; Chattopadhyay, J.; Dutta, B.K.

    2016-01-01

    Present paper deals with a detailed study on the correlation between minimum thickness (t/t_0) and central deflection (δ/t_0). Such data are obtained during the deformation of a small punch test of miniaturized specimen. Finite element studies have been carried out to investigate the effect of various parameters which are expected to influence this correlation. The parameters under consideration are material hardening, material yield stress, coefficient of friction and initial thickness of the specimen. It is shown that the correlation remains unaffected with respect to change in material parameters. Similarly, the coefficient of friction beyond 0.2 also does not affect the correlation. However, change in thickness has significant effect on the correlation. A modification has been suggested in the existing correlation to consider the influence of thickness change. The modified correlation is then used to calculate fracture toughness using the experimental results quoted in the literature. It is shown that the modified correlation improves the fracture toughness prediction considerably.

  14. Concepts for Small-Scale Testing of Used Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Marschman, Steven Craig [Idaho National Lab. (INL), Idaho Falls, ID (United States); Winston, Philip Lon [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This report documents a concept for a small-scale test involving between one and three Boiling Water Rector (BWR) high burnup (HBU) fuel assemblies. This test would be similar to the DOE funded High Burn-Up (HBU) Confirmatory Data Project to confirm the behavior of used high burn-up fuel under prototypic conditions, only on a smaller scale. The test concept proposed would collect data from fuel stored under prototypic dry storage conditions to mimic, as closely as possible, the conditions HBU UNF experiences during all stages of dry storage: loading, cask drying, inert gas backfilling, and transfer to an Independent Spent Fuel Storage Installation (ISFSI) for multi-year storage.

  15. Study of oxide film formed in a pre cracked CT specimen of AISI 304L during a rising displacement test in 288 C water

    International Nuclear Information System (INIS)

    Diaz S, A.; Castano M, V.

    2007-01-01

    A study of oxide film formed inside pre cracked CT specimens during a rising displacement test in high temperature water (288 C) was performed in this study, The environmental conditions used during the experiments were similar to these found in Boiling Water Reactors (BWR): Normal Water Condition (NWC - 200 ppb O 2 ) and Hydrogen Water Chemistry (HWC - 125 ppb H2). The oxide films formed were analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). In both cases the oxide film consisted of two layers identified as magnetite. In the case of HWC the results agree with previous reports that mention magnetite as a stable phase in reducing conditions. However the stable phase in oxidant conditions is hematite and this work shows the presence of magnetite crystals in the narrow crack of CT specimens in spite of the oxidant environmental condition. This situation confirms that inside the pre-cracked CT specimens the environmental conditions were different from the oxidant bulk, and probably a poor oxygen access and stagnant conditions within the narrow crack promoted a localized reducing environment that permitted the magnetite formation. Is evident that the crack growth studies should consider the conditions inside crack because they are significantly different. (Author)

  16. Postal dosimetry audit test for small photon beams

    International Nuclear Information System (INIS)

    Espinosa, María del Mar; Núñez, Luis; Muñiz, José Luis; Lagares, Juan Ignacio; Embid, Miguel; Gómez-Ros, José María

    2012-01-01

    Background and purpose: Small radiation beams ( 3 ) of TLD-100 inserted at 5 and 10 cm of depth in a cylindrical PMMA phantom designed for this purpose. This experimental system is mailed to the audited centres to be irradiated with beams of 1 and 3 cm of side or diameter. The prescribeddose is 1.5 Gy at 10 cm. The properties of this system were studied experimentally and by Monte Carlo (MC) simulation, before the external test. Results: Deviations between the prescribed and measured absorbed doses are below 5% for 69% (1 × 1 cm 2 beam) and 64% (3 × 3 cm 2 beam) of the audited centres. When deviations are above 5%, their causes have been investigated and led to corrections. Conclusion: The developed postal audit is suitable to verify the absorbed doses in small photon beams with an accuracy of 2.9% (1s).

  17. Standard test method for measurement of light reflectance value and small color differences between pieces of ceramic tile

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the measurement of Light Reflectance Value (LRV) and visually small color difference between pieces of glazed or unglazed ceramic tile, using any spectrophotometer that meets the requirements specified in the test method. LRV and the magnitude and direction of the color difference are expressed numerically, with sufficient accuracy for use in product specification. 1.2 LRV may be measured for either solid-colored tile or tile having a multicolored, speckled, or textured surface. For tile that are not solid-colored, an average reading should be obtained from multiple measurements taken in a pattern representative of the overall sample as described in 9.2 of this test method. Small color difference between tiles should only be measured for solid-color tiles. Small color difference between tile that have a multicolored, speckled, or textured surface, are not valid. 1.3 For solid colored tile, a comparison of the test specimen and reference specimen should be made under incandescent, f...

  18. Small Payload Launch Integrated Testing Services (SPLITS) - SPSDL

    Science.gov (United States)

    Plotner, Benjamin

    2013-01-01

    My experience working on the Small Payload Launch Integrated Testing Services project has been both educational and rewarding. I have been given the opportunity to work on and experiment with a number of exciting projects and initiatives, each offering different challenges and opportunities for teamwork and collaboration. One of my assignments is to aid in the design and construction of a small-scale two stage rocket as part of a Rocket University initiative. My duties include programming a microcontroller to control the various sensors on the rocket as well as process and transmit data. Additionally, I am writing a graphical user interface application for the ground station that will receive the transmitted data from the rocket and display the information on screen along with a 3D rendering displaying the rocket orientation. Another project I am working on is to design and develop the avionics that will be used to control a high altitude balloon flight that will test a sensor called a Micro Dosimeter that will measure the total ionizing dose absorbed by electrical components during a flight. This includes assembling and soldering the various sensors and components, programming a microcontroller to input and process data from the Micro Dosimeter, and transmitting the data down to a ground station as well as save the data to an on-board SD card. Additionally, I am aiding in the setup and development of ITOS (Integrated Test and Operations System) capability in the SPSDL (Spaceport Processing System Development Lab).

  19. Investigation of small break loss-of-coolant phenomena in a small scale nonnuclear test facility

    International Nuclear Information System (INIS)

    Cozzuol, J.M.; Fauble, T.J.; Harvego, E.A.

    1980-01-01

    A small-scale nonnuclear integral test facility designed to simulate a pressurized water reactor (PWR) system was used to evaluate the effects of a small break loss-of-coolant accident (LOCA) on the system thermal-hydraulic response. The experiment approximated a 2.5% (11-cm diameter) communicative break in the cold leg of a PWR, and included initial conditions which were similar to conditions in a PWR operating at full power. The 2.5% break size ensured that the nominal break flow rate was greater than the high pressure injection system (HPIS) flow rate, thus providing the potential for a continuous system depressurization. The sequence of events was similar to that used in evaluation model analysis of small break loss-of-coolant accidents, and included simulated reactor scram and loss of offsite power. Comparisions of experimental data with computer code calculations are used to demonstrate the capabilities and limitations of integral system calculations used to predict phenomena which can be important in the assessment of a small break LOCA in a PWR

  20. Development of small scale mechanical testing techniques on ion beam irradiated 304 SS

    International Nuclear Information System (INIS)

    Reichardt, A.; Abad, M.D.; Hosemann, P.; Lupinacci, A.; Kacher, J.; Minor, A.; Jiao, Z; Chou, P.

    2015-01-01

    Austenitic stainless steels are widely used for structural components in light water reactors, however uncertainty in their susceptibility to irradiation assisted stress corrosion cracking (IASCC) has made long term performance predictions difficult. In addition, the testing of reactor irradiated materials has proven challenging due to the long irradiation times required, limited sample availability, and unwanted activation. To address these problems, we apply recently developed techniques in nano-indentation and micro-compression testing to small volume samples of 10 dpa proton-beam irradiated 304 stainless steel. Cross sectional nano-indentation was performed on both proton beam irradiated and non-irradiated samples at temperatures ranging from 22 to 300 C. degrees to determine the effects of irradiation and operating temperature on hardening. Micro-compression tests using 2 μm x 2 μm x 5 μm focused-ion beam milled pillars were then performed in situ in an electron microscope to allow for a more accurate look at stress-strain behavior along with real-time observations of localized mechanical deformation. Large sudden slip events and significant increase in yield strength are observed in irradiated micro-compression samples at room temperature. Elevated temperature nano-indentation results reveal the possibility of thermally-activated changes in deformation mechanism for irradiated specimens. Since the deformation mechanism information provided by micro-compression testing can provide valuable information about IASCC susceptibility, future work will involve ex situ micro-compression tests at reactor operating temperature

  1. The effect of specimen and flaw dimensions on fracture toughness

    International Nuclear Information System (INIS)

    Nevalainen, M.J.

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account

  2. Influence of the gripping fixture on the modified compact tension test results: Evaluation of the experiments on cylindrical concrete specimens

    Czech Academy of Sciences Publication Activity Database

    Holušová, T.; Lozano, M.; Canteli, A.; Komárková, T.; Kocáb, D.; Seitl, Stanislav

    2015-01-01

    Roč. 15, č. 2 (2015) ISSN 1804-4824 Institutional support: RVO:68081723 Keywords : Modified compact tension test * fracture parametr * Cementitious composites * Aramis measurement * grips Subject RIV: JL - Materials Fatigue, Friction Mechanics

  3. A novel automatic molecular test for detection of multidrug resistance tuberculosis in sputum specimen: A case control study.

    Science.gov (United States)

    Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L

    2017-07-01

    MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.

  4. Small scale tests on the progressive retreat of soil slopes

    Science.gov (United States)

    Voulgari, Chrysoula; Utili, Stefano; Castellanza, Riccardo

    2015-04-01

    In this paper, the influence due to the presence of cracks on the morphologic evolution of natural cliffs subject to progressive retreat induced by weathering is investigated through small scale laboratory tests. Weathering turns hard rocks into soft rocks that maintain the structure of the intact rocks, but are characterised by higher void ratios and reduced bond strengths; soft rocks are transformed into granular soils generally called residual soils. A number of landslides develop in slopes due to weathering which results in the progressive retrogression of the slope face and the further degradation within the weathering zone. Cracks, that are widely present, can be a result of weathering and they can cause a significant decrease in their stability, as they provide preferential flow channels which increase the soil permeability and decrease the soil strength. The geological models employed until now are mainly empirical. Several researchers have tried to study the stability of slopes through experimental procedures. Centrifuge modelling is widely used to investigate the failure of slopes. Small scale tests are also an important approach, in order to study the behaviour of a slope under certain conditions, such as the existence of water, as they allow the observation of the infiltration processes, the movement of the weathering front, deformation and failure. However, the deformation response of a slope subject to weathering is not yet thoroughly clarified. In this work, a set of experiments were conducted to investigate weathering induced successive landslides. Weathering was applied to the slope model by wetting the slope crest through a rainfall simulator device. The moisture content of the soil during the tests was monitored by soil moisture sensors that were buried inside the slope model. High resolution cameras were recording the behaviour of the slope model. GeoPIV was used to analyse the frames and obtain the deformations of the slope model during the

  5. Small-scale tunnel test for blast performance

    International Nuclear Information System (INIS)

    Felts, J E; Lee, R J

    2014-01-01

    The data reported here provide a validation of a small-scale tunnel test as a tool to guide the optimization of new explosives for blast performance in tunnels. The small-scale arrangement consisted of a 2-g booster and 10-g sample mounted at the closed end of a 127 mm diameter by 4.6-m long steel tube with pressure transducers along its length. The three performance characteristics considered were peak pressure, initial energy release, and impulse. The relative performance from five explosives was compared to that from a 1.16-m diameter by 30-m long tunnel that used 2.27-kg samples. The peak pressure values didn't correlate between the tunnels. Partial impulse for the explosives did rank similarly. The initial energy release was determined from a one-dimensional point-source analysis, which nearly tracked with impulse suggesting additional energy released further down the tunnel for some explosives. This test is a viable tool for optimizing compositional variations for blast performance in target scenarios of similar geometry.

  6. Analytic and clinical performance of cobas HPV testing in anal specimens from HIV-positive men who have sex with men.

    Science.gov (United States)

    Wentzensen, Nicolas; Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V; Chen, Jie; Lorey, Thomas S; Gage, Julia C; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M; Castle, Philip E

    2014-08-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (P(trend) < 0.001), HPV18 (P(trend) = 0.07), and other carcinogenic types (P(trend) < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  7. Intensity of the Internal Standard Response as the Basis for Reporting a Test Specimen as Negative or Inconclusive

    Science.gov (United States)

    2007-08-01

    conclusive results in toxicology tests. Even under normal analytical conditions where the IS is poorly recovered, the substance may escape detection if it is...and en- zyme immunoassay of cannabis metabolites with gas chromatography/mass spectrometry analysis of 11-nor-Δ9-tetrahydrocannabinol-9- carboxylic

  8. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  9. Two-parameter fracture mechanical analysis of a near-crack-tip stress field in wedge splitting test specimens

    Czech Academy of Sciences Publication Activity Database

    Seitl, Stanislav; Veselý, V.; Řoutil, L.

    2011-01-01

    Roč. 89, 21-22 (2011), s. 1852-1858 ISSN 0045-7949. [International Conference on Civil, Structural and Enviromental Engineering Computing /12./. Funchal, Madeira, 01.09.2009-04.09.2009] Institutional research plan: CEZ:AV0Z20410507 Keywords : Wedge splitting test * Stress intensity factor * T-stress * Numerical simulation * Direct method Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.874, year: 2011

  10. The influence of the epoxy interlayer on the assessment of failure conditions of push-out test specimens

    Czech Academy of Sciences Publication Activity Database

    Klusák, Jan; Helincks, P.; Seitl, Stanislav; De Corte, W.; Boel, V.; De Schutter, G.

    525-526, č. 1 (2013), s. 61-64 ISSN 1013-9826 R&D Projects: GA ČR GAP108/10/2049; GA ČR(CZ) GAP105/11/1551 Institutional support: RVO:68081723 Keywords : push-out test * generalized fracture mechanics * failure initiation * steel-concrete joint * epoxy adhesive layer Subject RIV: JL - Materials Fatigue, Friction Mechanics

  11. Evaluation of laboratory tests for dengue diagnosis in clinical specimens from consecutive patients with suspected dengue in Belo Horizonte, Brazil.

    Science.gov (United States)

    Ferraz, Fernanda Oliveira; Bomfim, Maria Rosa Quaresma; Totola, Antônio Helvécio; Ávila, Thiago Vinícius; Cisalpino, Daniel; Pessanha, José Eduardo Marques; da Glória de Souza, Danielle; Teixeira Júnior, Antônio Lúcio; Nogueira, Maurício Lacerda; Bruna-Romero, Oscar; Teixeira, Mauro Martins

    2013-09-01

    Dengue is a widely spread arboviral disease in tropical and subtropical regions of the world. Dengue fever presents clinical characteristics similar to other febrile illness. Thus laboratory diagnosis is important for adequate management of the disease. The present study was designed to evaluate the diagnostic performance of real-time PCR and serological methods for dengue in a real epidemic context. Clinical data and blood samples were collected from consecutive patients with suspected dengue who attended a primary health care unit in Belo Horizonte, Brazil. Serologic methods and real-time PCR were performed in serum samples to confirm dengue diagnosis. Among the 181 consecutive patients enrolled in this study with suspected dengue, 146 were considered positive by serological criteria (positive NS1 ELISA and/or anti-dengue IgM ELISA) and 138 were positive by real-time PCR. Clinical criteria were not sufficient for distinguishing between dengue and non-dengue febrile illness. The PCR reaction was pre-optimized using samples from patients with known viral infection. It had similar sensitivity compared to NS1 ELISA (88% and 89%, respectively). We also evaluated three commercial lateral flow immunochromatographic tests for NS1 detection (BIOEASY, BIORAD and PANBIO). All three tests showed high sensitivity (94%, 91% and 81%, respectively) for dengue diagnosis. According to our results it can be suggested that lateral flow tests for NS1 detection are the most feasible methods for early diagnosis of dengue. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. [Identification of anaerobic gram-negative bacilli isolated from various clinical specimens and determination of antibiotic resistance profiles with E-test methods].

    Science.gov (United States)

    Demir, Cengiz; Keşli, Recep

    2018-01-01

    The aim of this study was to identify gram-negative anaerobic bacilli isolated from various clinical specimens that were obtained from patients with suspected anaerobic infections and to determine the antibiotic resistance profiles by using the antibiotic concentration gradient method. The study was performed in Afyon Kocatepe University Ahmet Necdet Sezer Research and Practice Hospital, Medical Microbiology Laboratory between 1 November 2014 and 30 October 2015. Two hundred and seventyeight clinical specimens accepted for anaerobic culture were enrolled in the study. All the samples were cultivated anaerobically by using Schaedler agar with 5% defibrinated sheep blood and Schaedler broth. The isolated anaerobic gram-negative bacilli were identified by using both the conventional methods and automated identification system (VITEK 2, bioMerieux, France). Antibiotic susceptibility tests were performed with antibiotic concentration gradient method (E-test, bioMerieux, France); against penicillin G, clindamycin, cefoxitin, metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem for each isolate. Of the 28 isolated anaerobic gram-negative bacilli; 14 were identified as Bacteroides fragilis group, 9 were Prevotella spp., and 5 were Fusobacterium spp. The highest resistance rate was found against penicillin (78.5%) and resistance rates against clindamycin and cefoxitin were found as 17.8% and 21.4%, respectively. No resistance was found against metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem. As a result, isolation and identification of anaerobic bacteria are difficult, time-consuming and more expensive when compared with the cost of aerobic culture. The rate of anaerobic bacteria isolation may be increased by obtaining the appropriate clinical specimen and appropriate transportation of these specimens. We believe that the data obtained from the study in our center may offer benefits for the follow up and treatment of infections

  13. Low upper-shelf toughness, high transition temperature test insert in HSST [Heavy Section Steel Technology] PTSE-2 [Pressurized Thermal Shock Experiment-2] vessel and wide plate test specimens: Final report

    International Nuclear Information System (INIS)

    Domian, H.A.

    1987-02-01

    A piece of A387, Grade 22 Class 2 (2-1/4 Cr - 1 Mo) steel plate specially heat treated to produce low upper-shelf (LUS) toughness and high transition temperature was installed in the side wall of Heavy Section Steel Technology (HHST) vessel V-8. This vessel is to be tested by the Oak Ridge National Laboratory (ORNL) in the Pressurized Thermal Shock Experiment-2 (PTSE-2) project of the HSST program. Comparable pieces of the plate were made into six wide plate specimens and other samples. These samples underwent tensile tests, Charpy tests, and J-integral tests. The results of these tests are given in this report

  14. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  15. Non-Small Cell Carcinoma Biomarker Testing: The Pathologist's Perspective.

    Directory of Open Access Journals (Sweden)

    Elisa eBrega

    2014-07-01

    Full Text Available Biomarker testing has become standard of care for patients diagnosed with non-small cell lung cancer. Although it can be successfully performed in circulating tu-mor cells, at present, the vast majority of investigations are carried out using di-rect tumor sampling, either through aspiration methods, which render most often isolated cells, or tissue sampling, that could range from minute biopsies to large resections. Consequently, pathologists play a central role in this process. Recent evidence suggests that refining NSCLC diagnosis might be clinically signifi-cant, particularly in cases of lung adenocarcinomas (ADC, which in turn, has prompted a new proposal for the histologic classification of such pulmonary neo-plasms. These changes, in conjunction with the mandatory incorporation of biomarker testing in routine NSCLC tissue processing, have directly affected the pathologist’s role in lung cancer work-up. This new role pathologists must play is complex and demanding, and requires a close interaction with surgeons, oncologists, radiologists and molecular pathologists. Pathologists often find themselves as the central figure in the coordination of a process, that involves assuring that the tumor samples are properly fixed, but without disruption of the DNA structure, obtaining the proper diagnosis with a minimum of tissue waste, providing pre-analytical evaluation of tumor samples selected for biomarker testing, which includes assessment of the proportion of tumor to normal tissues, as well as cell viability, and assuring that this entire pro-cess happens in a timely fashion. Therefore, it is part of the pathologist’s respon-sibilities to assure that the samples received in their laboratories, be processed in a manner that allows for optimal biomarker testing. This article goal is to discuss the essential role pathologists must play NSCLC bi-omarker testing, as well as to provide a summarized review of the main NSCLC bi-omarkers of

  16. Exact association test for small size sequencing data.

    Science.gov (United States)

    Lee, Joowon; Lee, Seungyeoun; Jang, Jin-Young; Park, Taesung

    2018-04-20

    Recent statistical methods for next generation sequencing (NGS) data have been successfully applied to identifying rare genetic variants associated with certain diseases. However, most commonly used methods (e.g., burden tests and variance-component tests) rely on large sample sizes. Notwithstanding, due to its-still high cost, NGS data is generally restricted to small sample sizes, that cannot be analyzed by most existing methods. In this work, we propose a new exact association test for sequencing data that does not require a large sample approximation, which is applicable to both common and rare variants. Our method, based on the Generalized Cochran-Mantel-Haenszel (GCMH) statistic, was applied to NGS datasets from intraductal papillary mucinous neoplasm (IPMN) patients. IPMN is a unique pancreatic cancer subtype that can turn into an invasive and hard-to-treat metastatic disease. Application of our method to IPMN data successfully identified susceptible genes associated with progression of IPMN to pancreatic cancer. Our method is expected to identify disease-associated genetic variants more successfully, and corresponding signal pathways, improving our understanding of specific disease's etiology and prognosis.

  17. Small-Scale Testing of Laterally Loaded Monopiles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Roesen, Hanne Ravn; Ibsen, Lars Bo

    2011-01-01

    of small-scale laboratory tests. Six quasi-static tests are conducted on piles with diameters of 40mm and 100mm and a slenderness ratio, L/D, of 5. To minimise scale effects, the tests are carried out in a pressure tank at various stress levels. From the obtained load-deflection relationships......In current designs of offshore wind turbines, monopiles are often used as foundation. The behaviour of the monopoles when subjected to lateral loading has not been fully investigated. In this paper, the behaviour of two non-slender piles in sand subjected to lateral loading are analysed by means...... it is revealed that the uncertainties of the results for the pile with a diameter of 40mm are large. The load-deflection relationships normalised as H/(L2Dγ’) and y/D indicate that the lateral load, H, is proportional to L2D. Comparison of the normalised load-deflection relationships for different stress levels...

  18. Evaluation of chromogenic medium and direct latex agglutination test for detection of group B streptococcus in vaginal specimens from pregnant women in Lebanon and Kuwait.

    Science.gov (United States)

    Ghaddar, Nahed; Alfouzan, Wadha; Anastasiadis, Elie; Al Jiser, Tamima; Itani, Saad Eddine; Dernaika, Racha; Eid, Toufic; Ghaddar, Ali; Charafeddine, Adib; Dhar, Rita; El Hajj, Hiba

    2014-10-01

    This study was undertaken to evaluate chromogenic medium and a direct latex agglutination test (DLA) for detection of Group B Streptococcus (GBS) in the vaginal specimens of pregnant women, and to ascertain the prevalence of GBS in this population in Kuwait and Lebanon. Vaginal swabs, collected from women at 35-37 weeks of gestation, were cultured on 5 % sheep blood agar (SBA), colistin nalidixic acid agar (CNA), Strept B Select chromogenic agar (SBS) as well as Lim enrichment broth in 168 cases in Lebanon while only SBA was used for 1391 samples in Kuwait. In addition, vaginal samples from 102 GBS-positive and 20 GBS-negative women near the time of delivery were collected in Kuwait for evaluation of the DLA test. During the study period, the prevalence of GBS colonization was determined to be 20.7 % (288/1391) in Kuwait while 18.4 % (31) of 168 pregnant women in Lebanon had vaginal cultures positive for GBS. By direct plating of vaginal swabs on the three media used, the isolation rates of GBS were 51.6, 64.5 and 77.4 % on SBA, CNA and SBS, respectively, which increased to 90.35, 93.1 and 96.8 %, respectively, following subculture in Lim broth after 18 h of incubation. The sensitivity of the DLA test was found to be dependent on the density of GBS colonization, resulting in 100 % sensitivity and 100 % specificity for heavy (>10(2) c.f.u. per swab) and moderately heavy (50-100 c.f.u. per swab) growth of GBS. However, for vaginal specimens yielding women. The DLA test, in particular, could prove to be a useful tool for immediate detection of GBS in women near delivery so that intrapartum antibiotic prophylaxis can be initiated. © 2014 The Authors.

  19. Automation of the linear array HPV genotyping test and its application for routine typing of human papillomaviruses in cervical specimens of women without cytological abnormalities in Switzerland.

    Science.gov (United States)

    Dobec, Marinko; Bannwart, Fridolin; Kaeppeli, Franz; Cassinotti, Pascal

    2009-05-01

    There is a need for reliable, automated high throughput HPV detection and genotyping methods for pre- and post-prophylactic vaccine intervention analyses. To optimize the linear array (LA) HPV genotyping test (Roche Diagnostics, Rotkreuz) in regard to possible automation steps for the routine laboratory diagnosis of HPV infections and to analyze the HPV genotype distribution in cervical specimens of women without cytological abnormalities in Switzerland. 680 cervical cell specimens with normal cytology, obtained from women undergoing routine cervical screening by liquid-based Pap smear, were analyzed by the LA HPV genotyping test for HPV-DNA. The automation of the LA HPV genotyping test resulted in a total hands-on time reduction of 255 min (from 480 to 225 min; 53%). Any of 37 HPV genotypes were detected in 117 (17.2%) and high-risk (HR) HPV in 55 (8.1%) of 680 women with normal cytology. The highest prevalence of any HPV (28.1%) and HR-HPV (15.1%) was observed in age-group 21-30 and showed a continuous decrease in older age-groups. The most common HR-HPV genotypes were HPV-16 (12%), HPV-31 (9.4%), HPV-52 (6%), HPV-51 (5.1%), HPV-45 (4.3%), HPV-58 (4.3%) and HPV-59 (4.3%). The optimization and automation of the LA HPV genotyping test makes it suited for high throughput HPV detection and typing. The epidemiological data provides information about distribution of HPV genotypes in women without cytological abnormalities in Switzerland and may be important for determining the future impact of vaccines and potential changes in the country's epidemiological HPV profile.

  20. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    Science.gov (United States)

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  1. Performance testing of a small vertical-axis wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, R.; Tullis, S.; Ziada, S. [McMaster Univ., Hamilton, ON (Canada). Dept. of Mechanical Engineering

    2007-07-01

    Full-scale wind tunnel testing of a prototype 3.5 kW vertical-axis wind turbine (VAWT) was conducted in a low speed wind tunnel in Ottawa. The tests were conducted to determine nominal power curves as well as the system's structural integrity, safety and operational characteristics. Dimensionless power curves were used to assess the relation between the wind turbine's rotary speed and the produced power for various wind speeds. Tests began at the lowest wind speed and revolutions per minute (RPM) and were gradually increased. A proximity sensor was used to determine the passing frequency of spaced bolts. The aerodynamic performance of the turbine was evaluated using a servo-controlled mechanical variable load with a disc brake calliper and electro-hydraulic servo-actuator. A load cell was used to measure torque produced by the turbine. An active closed loop speed control system was used to regulate the rotary speed of the turbine. The system used a high gain proportional control law to guarantee stability. Calculated power was based on the average rotary speed measurement. Results of the study suggested that the dimensional power performance of the turbine could be predicted from the curve for all rotary speeds and for wind speeds between 8 and 16 m/s. The maximum power coefficient of 0.3 occurred at a tip speed ratio of 1.6. Test results demonstrated that the turbine reached its rated power at 14 m/s. However, the range of tip speed ratios for power production were lower than the range for most other small VAWT. 2 refs., 3 figs.

  2. Computational model for simulation small testing launcher, technical solution

    Energy Technology Data Exchange (ETDEWEB)

    Chelaru, Teodor-Viorel, E-mail: teodor.chelaru@upb.ro [University POLITEHNICA of Bucharest - Research Center for Aeronautics and Space, Str. Ghe Polizu, nr. 1, Bucharest, Sector 1 (Romania); Cristian, Barbu, E-mail: barbucr@mta.ro [Military Technical Academy, Romania, B-dul. George Coşbuc, nr. 81-83, Bucharest, Sector 5 (Romania); Chelaru, Adrian, E-mail: achelaru@incas.ro [INCAS -National Institute for Aerospace Research Elie Carafoli, B-dul Iuliu Maniu 220, 061126, Bucharest, Sector 6 (Romania)

    2014-12-10

    The purpose of this paper is to present some aspects regarding the computational model and technical solutions for multistage suborbital launcher for testing (SLT) used to test spatial equipment and scientific measurements. The computational model consists in numerical simulation of SLT evolution for different start conditions. The launcher model presented will be with six degrees of freedom (6DOF) and variable mass. The results analysed will be the flight parameters and ballistic performances. The discussions area will focus around the technical possibility to realize a small multi-stage launcher, by recycling military rocket motors. From technical point of view, the paper is focused on national project 'Suborbital Launcher for Testing' (SLT), which is based on hybrid propulsion and control systems, obtained through an original design. Therefore, while classical suborbital sounding rockets are unguided and they use as propulsion solid fuel motor having an uncontrolled ballistic flight, SLT project is introducing a different approach, by proposing the creation of a guided suborbital launcher, which is basically a satellite launcher at a smaller scale, containing its main subsystems. This is why the project itself can be considered an intermediary step in the development of a wider range of launching systems based on hybrid propulsion technology, which may have a major impact in the future European launchers programs. SLT project, as it is shown in the title, has two major objectives: first, a short term objective, which consists in obtaining a suborbital launching system which will be able to go into service in a predictable period of time, and a long term objective that consists in the development and testing of some unconventional sub-systems which will be integrated later in the satellite launcher as a part of the European space program. This is why the technical content of the project must be carried out beyond the range of the existing suborbital

  3. Comparison of fracture toughness values from an IPIRG-1 large-scale pipe system test and C(T) specimens on wrought TP304 stainless steel

    International Nuclear Information System (INIS)

    Olson, R.J.; Scott, P.; Marschall, C.W.; Wilkowski, G.M.

    1994-01-01

    Within the First International Piping Integrity Research Group (IPIRG-1) program, pipe system experiments involving dynamic loading with intentionally circumferentially cracked pipe were conducted. The pipe system was fabricated from 406-mm (16-inch) diameter Schedule 100 pipe, and the experiments were conducted at a pressure of 15.5 MPa (2,250 psi) and 288 C (550 F). The loads consisted of pressure, dead-weight, thermal expansion, inertia, and dynamic anchor motion. Significant instrumentation was used to allow the material fracture resistance to be calculated from these large-scale experiments. Three independent analyses were used to calculate the toughness directly from one of these pipe experiments. A comparison of the toughness values from the stainless steel base metal pipe experiment to standard quasi-static and dynamic C(T) specimen tests showed the pipe toughness value was significantly lower than that obtained from C(T) specimens. It is hypothesized that the cyclic loading from inertial stresses in this pipe system experiment caused local degradation of the material toughness. Such effects are not considered in current LBB or pipe flaw evaluation criteria

  4. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    Science.gov (United States)

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  5. Fracture toughness of Charpy-size compound specimens and its application in engineering

    International Nuclear Information System (INIS)

    Zhang, X.P.; Shi, Y.W.

    1994-01-01

    The use of a pre-cracked Charpy-size specimen with a side-groove to evaluate the fracture toughness of materials has been researched and considered. This method not only satisfies the demand for small-size specimens in surveillance tests of fracture toughness but also avoids using complicated physical methods to monitor the initial conditions of crack propagation. For most materials this method has solved the problem in which the small-size specimen did not satisfy the valid conditions of a fracture toughness measurement. In order to obtain more information from neutron-irradiated sample specimens and raise the reliability of fracture toughness surveillance tests, it has been considered more important to repeatedly exploit the broken Charpy-size specimen tested in the surveillance test, and to make it renewable. In this work, on the renewing design and utilization of Charpy-size specimens, nine data on fracture toughness can be obtained from one pre-cracked side-grooved Charpy-size specimen, while at present usually only one to three data on fracture toughness can be obtained from one Charpy-size specimen. Thus, it is found that the new method would improve the reliability of fracture toughness surveillance testing and evaluation. In addition, some factors that affect the optimum design of pre-cracked deep side-groove Charpy-size compound specimens have also been discussed. (author)

  6. Rapid point-of-care testing for epidermal growth factor receptor gene mutations in patients with lung cancer using cell-free DNA from cytology specimen supernatants.

    Science.gov (United States)

    Asaka, Shiho; Yoshizawa, Akihiko; Saito, Kazusa; Kobayashi, Yukihiro; Yamamoto, Hiroshi; Negishi, Tatsuya; Nakata, Rie; Matsuda, Kazuyuki; Yamaguchi, Akemi; Honda, Takayuki

    2018-06-01

    Epidermal growth factor receptor (EGFR) mutations are associated with responses to EGFR tyrosine kinase inhibitors (EGFR-TKIs) in non-small-cell lung cancer (NSCLC). Our previous study revealed a rapid point-of-care system for detecting EGFR mutations. This system analyzes cell pellets from cytology specimens using droplet-polymerase chain reaction (d-PCR), and has a reaction time of 10 min. The present study aimed to validate the performance of the EGFR d-PCR assay using cell-free DNA (cfDNA) from supernatants obtained from cytology specimens. Assay results from cfDNA supernatant analyses were compared with those from cell pellets for 90 patients who were clinically diagnosed with, or suspected of having, lung cancer (80 bronchial lavage fluid samples, nine pleural effusion samples and one spinal fluid sample). EGFR mutations were identified in 12 and 15 cases using cfDNA supernatants and cell pellets, respectively. The concordance rates between cfDNA-supernatant and cell‑pellet assay results were 96.7% [kappa coefficient (K)=0.87], 98.9% (K=0.94), 98.9% (K=0.79) and 98.9% (K=0.79) for total EGFR mutations, L858R, E746_A750del and T790M, respectively. All 15 patients with EGFR mutation-positive results, as determined by EGFR d-PCR assay using cfDNA supernatants or cell pellets, also displayed positive results by conventional EGFR assays using tumor tissue or cytology specimens. Notably, EGFR mutations were even detected in five cfDNA supernatants for which the cytological diagnoses of the corresponding cell pellets were 'suspicious for malignancy', 'atypical' or 'negative for malignancy.' In conclusion, this rapid point-of-care system may be considered a promising novel screening method that may enable patients with NSCLC to receive EGFR-TKI therapy more rapidly, whilst also reserving cell pellets for additional morphological and molecular analyses.

  7. A simple and low-toxic method of preparing small specimens of bacteria, flagellates and their likes for Scanning Electron Microscopy

    DEFF Research Database (Denmark)

    Møller, O. S.; Buchman, K.; Dalsgaard, Inger

    2013-01-01

    The preparation of samples of bacteria and other very small organisms (Electron Microscopy is often complex and intricate, which typically involve the use of specialized filter systems, complex handling and toxic chemicals. Based on the methods described in the literature...

  8. An investigation of normal urine with a creatinine concentration under the cutoff of 20 mg/dL for specimen validity testing in a toxicology laboratory.

    Science.gov (United States)

    Holden, Brad; Guice, Erica A

    2014-05-01

    In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.

  9. Numerical development of a new correlation between biaxial fracture strain and material fracture toughness for small punch test

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Pradeep [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Dutta, B.K., E-mail: bijon.dutta@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Chattopadhyay, J. [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Reactor Safety Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2017-04-01

    The miniaturized specimens are used to determine mechanical properties of the materials, such as yield stress, ultimate stress, fracture toughness etc. Use of such specimens is essential whenever limited quantity of material is available for testing, such as aged/irradiated materials. The miniaturized small punch test (SPT) is a technique which is widely used to determine change in mechanical properties of the materials. Various empirical correlations are proposed in the literature to determine the value of fracture toughness (J{sub IC}) using this technique. bi-axial fracture strain is determined using SPT tests. This parameter is then used to determine J{sub IC} using available empirical correlations. The correlations between J{sub IC} and biaxial fracture strain quoted in the literature are based on experimental data acquired for large number of materials. There are number of such correlations available in the literature, which are generally not in agreement with each other. In the present work, an attempt has been made to determine the correlation between biaxial fracture strain (ε{sub qf}) and crack initiation toughness (J{sub i}) numerically. About one hundred materials are digitally generated by varying yield stress, ultimate stress, hardening coefficient and Gurson parameters. Such set of each material is then used to analyze a SPT specimen and a standard TPB specimen. Analysis of SPT specimen generated biaxial fracture strain (ε{sub qf}) and analysis of TPB specimen generated value of J{sub i}. A graph is then plotted between these two parameters for all the digitally generated materials. The best fit straight line determines the correlation. It has been also observed that it is possible to have variation in J{sub i} for the same value of biaxial fracture strain (ε{sub qf}) within a limit. Such variation in the value of J{sub i} has been also ascertained using the graph. Experimental SPT data acquired earlier for three materials were then used to get J

  10. Fluid flow measurements of Test Series A and B for the Small Scale Seal Performance Tests

    International Nuclear Information System (INIS)

    Peterson, E.W.; Lagus, P.L.; Lie, K.

    1987-12-01

    The degree of waste isolation achieved by a repository seal system is dependent upon the fluid flow characteristics, or permeability, of the seals. In order to obtain meaningful, site-specific data on the performance of various possible seal system components, a series of in situ experiments called the Small Scale Seal Performance Tests (SSSPT) are being conducted at the Waste Isolation Pilot Plant (WIPP). This report contains the results of gas flow, tracer penetration, and brine flow tests conducted on concrete seals in vertical (Test Series A) and horizontal (Test Series B) configurations. The test objectives were to evaluate the seal performance and to determine if there existed scaling effects which could influence future SSSPT designs. 3 refs., 77 figs

  11. Progress in generating fracture data base as a function of loading rate and temperature using small-scale tests

    International Nuclear Information System (INIS)

    Couque, H.; Hudak, S.J. Jr.

    1993-01-01

    Structural integrity assessment of nuclear pressure vessels requires small specimen fracture testing to generate data over a wide range of material loading, and temperature conditions. Small scale testing is employed since extensive testing is required including small radiation embrittled samples from nuclear surveillance capsules. However, current small scale technology does not provide the needed dynamic fracture toughness relevant to the crack arrest/reinitiation events that may occur during pressurized thermal shock transients following emergency shutdown. This paper addresses the generation of this much needed dynamic toughness data using a novel experimental-computational approach involving a coupled pressure bars (CPB) technique and a viscoplastic dynamic fracture code. CPB data have been generated to testing temperatures never before reached: 37 to 100 degrees C -- 60 to 123 degrees C above the nil ductility transition temperature. Fracture behavior of pressure vessel steel from lower shelf to upper shelf temperatures and previous toughness estimates for the 10 6 MPa√m s -1 loading rate regime are assessed in light of the new CPB data. 26 refs., 14 figs., 3 tabs

  12. A Study on the Small Punch Test for Fracture Strength Evaluation of CANDU Pressure Tube Embrittled by Hydrogen

    International Nuclear Information System (INIS)

    Nho, Seung Hwan; Ong, Jang Woo; Yu, Hyo Sun; Chung, Se Hi

    1996-01-01

    The purpose of this study is to investigate the usefulness of small punch(SP) test using miniaturized specimens as a method for fracture strength evaluation of CANDU pressure tube embrittled by hydrogen. According to the test results, the fracture strength evaluation as a function of hydrogen concentration at -196 .deg. C was much better than that at room temperature, as the difference of SP fracture energy(Esp) with hydrogen concentration was more significant at -196 .deg. C than at room temperature for the hydrogen concentration up to 300ppm-H. It was also observed that the peak of average AE energy, the cumulative average AE energy and the cumulative average AE energy per equivalent fracture, strain increased with the increase of hydrogen concentration. From the results of load-displacement behaviors, Esp behaviors, macro- and micro-SEM fractographs and AE test it has been concluded that the SP test method using miniaturized specimen(10mmx10mmx0.5mm) will be a useful test method to evaluate the fracture strength for CANDU pressure tube embrittled by hydrogen

  13. Influence of specimen size on the creep of rock salt

    International Nuclear Information System (INIS)

    Senseny, P.E.

    1982-01-01

    Triaxial compression creep data for Avery Island dome salt are analyzed to determine the influence of specimen size on creep deformation. Laboratory experiments were performed on 50- and 100-mm-diameter specimens in the temperature range from 25 to 200 0 C and the axial stress difference range from 2.5 to 31.0 MPa. The strain-vs-time data from each test are divided into transient and steady-state components. Results of statistical analysis of these data show that transient creep of the small specimens is a stronger function of stress, temperature, and time than is transient creep of the larger specimens. Analysis of the steady-state data show no size effect, however. 14 references, 7 figures, 3 tables

  14. Addendum to ''Test Plan: Small-Scale Seal Performance Tests (SSSPT)''

    International Nuclear Information System (INIS)

    Finley, R.E.

    1992-01-01

    This document describes activities that are intended to update the data base of fluid flow measurements made on expansive salt concrete (ESC) seals as part of the Small-Scale Seal Performance Tests (SSSPT). The original plans for the SSSPT experiments are described by Stormont (1985a and 1985b). These seals have previously been tested with brine and gas during the early stages (less than 450 days) after emplacement. The purpose of this Test Plan Addendum is to detail the activities necessary to, update the gas and brine measurements previously performed on the SSSPT Series A and Series B seals and to identify the key personnel responsible for implementing these activities. This addendum describes a limited undertaking and does NOT change the scope of the original test plan

  15. Accelerated aging, natural aging, and small punch testing of gamma-air sterilized polycarbonate urethane acetabular components.

    Science.gov (United States)

    Kurtz, S M; Siskey, R; Reitman, M

    2010-05-01

    The objectives of this study were three-fold: (1) to determine the applicability of the small punch test to characterize Bionate 80A polycarbonate urethane (PCU) acetabular implants; (2) to evaluate the susceptibility of PCU acetabular implants to exhibit degradation of mechanical behavior following gamma irradiation in air and accelerated aging; and (3) to compare the oxidation of gamma-air sterilized PCU following accelerated aging and 5 years of natural shelf aging. In addition to attenuated total reflectance-Fourier transform infrared spectroscopy, we also adapted a miniature specimen mechanical test, the small punch test, for the deformable PCU cups. Accelerated aging was performed using ASTM F2003, a standard test that represents a severe oxidative challenge. The results of this study suggest that the small punch test is sufficiently sensitive and reproducible to discriminate slight differences in the large-deformation mechanical behavior of Bionate 80A following accelerated aging. The gamma-air sterilized PCU had a reduction of 9% in ultimate load after aging. Five years of shelf aging had little effect on the mechanical properties of the PCU. Overall, our findings suggest that the Bionate 80A material has greater oxidative stability than ultra-high molecular weight polyethylene following gamma irradiation in air and exposure to a severe oxidative challenge. (c) 2010 Wiley Periodicals, Inc.

  16. The study of the irradiation-induced embrittlement of reactor pressure vessels. Analysis of surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Nagai, Yasuyoshi; Toyama, Takeshi; Hasegawa, Masayuki

    2007-01-01

    The study of embrittlement of nuclear power reactor pressure vessels (RPVs) is of critical importance for the safety assessment in the nuclear industry. Some origins of embrittlement are attributed to fine Cu precipitates, matrix defects, grain boundary segregation of P and late blooming phase. This review article described nanostructural observation by three-dimensional atom probe (3DAP) and positron annihilation spectroscopy (PAS). The density and sizes of Cu-rich nanoprecipitates and grain boundary segregation are sensitively detected by 3DAP, and vacancies are probed by PAS. Element analysis around vacancies and fine microstructural Cu precipitates not containing vacancies are successfully observed by a coincidence doppler broadening method. The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of commercial nuclear reactor pressure vessel steel welds of Doel-2 in Belgium were revealed by combining 3DAP and PAS. In both medium (0.13 wt%) and high (0.30 wt%) Cu welds, the CRNPs were found to form readily at the very beginning of the reactor lifetime. On the other hand, small vacancy clusters start appearing after the initial Cu precipitates and accumulate steadily with increasing neutron dose. The CRNPs were also observed at very low dose rate of neutrons in the test specimen of Calder Hall Reactor of Japan Atomic Power Company. The significant enhancement of these Cu precipitates results in the embrittlement in practical RPVs. At very high dose of 2.2x10 18 n/cm 2 by JMTR, the Cu precipitates were scarcely observed, and the irradiation-induced embrittlement was primarily caused from vacancy-impurity complexes and dislocation loops. (author)

  17. DHS small-scale safety and thermal testing of improvised explosives-comparison of testing performance

    International Nuclear Information System (INIS)

    Reynolds, J G; Hsu, P C; Sandstrom, M M; Brown, G W; Warner, K F; Phillips, J J; Shelley, T J; Reyes, J A

    2014-01-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or homemade explosives (HMEs) to SSST testing, 16 HME materials were compared to three standard military explosives in a proficiency-type round robin study among five laboratories-two DoD and three DOE-sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials-powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. More than 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for developing safe handling and storage practices. This paper presents a generalized comparison of the results among the testing participants, comparison of friction results from BAM (German Bundesanstalt für Materi-alprüfung) and ABL (Allegany Ballistics Laboratory) designed testing equipment, and an overview of the statistical results from the RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) standard tested throughout the proficiency test.

  18. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  19. Small passenger car transmission test; Chevrolet LUV transmission

    Science.gov (United States)

    Bujold, M. P.

    1980-01-01

    A 1978 Chevrolet LUV manual transmission tested per the applicable portions of a passenger car automatic transmission test code (SAE J65lb) which required drive performance, coast performance, and no load test conditions. Under these test conditions, the transmission attained maximum efficiencies in the upper ninety percent range for both drive performance tests and coast performance tests. The major results of this test (torque, speed, and efficiency curves) are presented. Graphs map the complete performance characteristics for the Chevrolet LUV transmission.

  20. Results of charpy V-notch impact testing of structural steel specimens irradiated at ∼30 degrees C to 1 x 1016 neutrons/cm2 in a commercial reactor cavity

    International Nuclear Information System (INIS)

    Iskander, S.K.; Stoller, R.E.

    1997-04-01

    A capsule containing Charpy V-notch (CVN) and mini-tensile specimens was irradiated at ∼ 30 degrees C (∼ 85 degrees F) in the cavity of a commercial nuclear power plant to a fluence of 1 x 10 16 neutrons/cm 2 (> 1MeV). The capsule included six CVN impact specimens of archival High Flux Isotope Reactor A212 grade B ferritic steel and five CVN impact specimens of a well-studied A36 structural steel. This irradiation was part of the ongoing study of neutron-induced damage effects at the low temperature and flux experienced by reactor supports. The plant operators shut down the plant before the planned exposure was reached. The exposure of these specimens produced no significant irradiation-induced embrittlement. Of interest were the data on unirradiated specimens in the L-T orientation machined from a single plate of A36 structural steel, which is the same specification for the structural steel used in some reactor supports. The average CVN energy of five unirradiated specimens obtained from one region of the plate and tested at room temperature was ∼ 99 J, while the energy of 11 unirradiated specimens from other locations of the same plate was 45 J, a difference of ∼ 220%. The CVN impact energies for all 18 specimens ranged from a low of 32 J to a high of 111 J. Moreover, it appears that the University of Kansas CVN impact energy data of the unirradiated specimens at the 100-J level are shifted toward higher temperatures by about 20 K. The results were an example of the extent of scatter possible in CVN impact testing. Generic values for the CVN impact energy of A36 should be used with caution in critical applications

  1. Small-bore-piping seismic-test findings

    International Nuclear Information System (INIS)

    Severud, L.K.; Barta, D.A.; Anderson, M.J.

    1981-12-01

    Description is given of a test series in which a 1-inch diameter stainless steel pipe system was subjected to dynamic testing. The test system consisted of approximately 40-feet of schedule 40 pipe, with several bends and risers, supported from a rigid test frame. FFTF prototypic pipe clamps, dead weight supports, mechanical snubbers, and insulation were utilized. Several variations of the pipe support configuration were tested. Measured test results are compared with analytical predictions for each configuration. Plans for future testing are discussed

  2. The small displacement elastic solution to the ball-on-ring testing method

    DEFF Research Database (Denmark)

    Frandsen, Henrik Lund

    2012-01-01

    The ball-on-ring experiment is used for testing of the biaxial strength of ceramics. In this work the solution for the stress distribution and displacements of the disc specimen in the ball-on-ring experiment are determined on closed form. The solution comprises the displacement field and its...

  3. External quality assessment in the voluntary counseling and testing centers in the Brazilian Amazon using dried tube specimens: results of an effectiveness evaluation

    Directory of Open Access Journals (Sweden)

    Andréa Mônica Brandão Beber

    2015-06-01

    Full Text Available INTRODUCTION : In 2011, the Brazilian Ministry of Health rolled out a program for the external quality assessment of rapid human immunodeficiency virus (HIV tests using the dried tube specimen (DTS method (EQA-RT/DTS-HIV. Our objective was to evaluate the implementation of this program at 71 voluntary counseling and testing centers (VCTCs in the Brazilian Legal Amazonian area one year after its introduction. METHODS : Quantitative and qualitative study that analyzed secondary data and interviews with healthcare workers (HCWs (n=39 and VCTC coordinators (n=32 were performed. The assessment used 18 key indicators to evaluate the three dimensions of the program's logical framework: structure, process, and result. Each indicator was scored from 1-4, and the aggregate results corresponding to the dimensions were expressed as proportions. The results were compared to the perceptions of the HCWs and coordinators regarding the EQA-RT/DTS-HIV program. RESULTS: The aggregate scores for the three dimensions of structure, process, and result were 91.7%, 78.6%, and 95%, respectively. The lowest score in each dimension corresponded to a different indicator: access to Quali-TR online system 39% (structure, registration in Quali-TR online system 38.7% (process, and VCTC completed the full process in the program's first round 63.4% (result. Approximately 36% of the HCWs and 52% of the coordinators reported enhanced trust in the program for its rapid HIV testing performance. CONCLUSIONS: All three program dimensions exhibited satisfactory results (>75%. Nevertheless, the study findings highlight the need to improve certain program components. Additionally, long-term follow-ups is needed to provide a more thorough picture of the process for external quality assessment.

  4. Multiple Irradiation Capsule Experiment (MICE)-3B Irradiation Test of Space Fuel Specimens in the Advanced Test Reactor (ATR) - Close Out Documentation for Naval Reactors (NR) Information

    Energy Technology Data Exchange (ETDEWEB)

    M. Chen; CM Regan; D. Noe

    2006-01-09

    Few data exist for UO{sub 2} or UN within the notional design space for the Prometheus-1 reactor (low fission rate, high temperature, long duration). As such, basic testing is required to validate predictions (and in some cases determine) performance aspects of these fuels. Therefore, the MICE-3B test of UO{sub 2} pellets was designed to provide data on gas release, unrestrained swelling, and restrained swelling at the upper range of fission rates expected for a space reactor. These data would be compared with model predictions and used to determine adequacy of a space reactor design basis relative to fission gas release and swelling of UO{sub 2} fuel and to assess potential pellet-clad interactions. A primary goal of an irradiation test for UN fuel was to assess performance issues currently associated with this fuel type such as gas release, swelling and transient performance. Information learned from this effort may have enabled use of UN fuel for future applications.

  5. Cytology specimens offer an effective alternative to formalin-fixed tissue as demonstrated by novel automated detection for ALK break-apart FISH testing and immunohistochemistry in lung adenocarcinoma.

    Science.gov (United States)

    Rosenblum, Frida; Hutchinson, Lloyd M; Garver, Joann; Woda, Bruce; Cosar, Ediz; Kurian, Elizabeth M

    2014-11-01

    Minimally invasive sampling by cytology or core needle biopsy often provides an initial diagnosis for treatment in patients with lung nodules. From these limited specimens, multiple molecular studies are frequently requested. Current guidelines from the US Food and Drug Administration recommend using formalin-fixed paraffin-embedded tissue sections for the detection of anaplastic lymphoma kinase (ALK) gene rearrangement by fluorescence in situ hybridization (FISH). The authors compared alcohol-fixed and formalin-fixed cytology specimens using a novel automated detection for ALK rearrangements by FISH and immunohistochemistry (IHC). ALK FISH testing was performed on 129 lung adenocarcinomas from 71 cytology cases and 58 biopsy/resection specimens using Papanicolaou staining with integrated cytomorphology. IHC with the ALK D5F3 antibody was performed on cases with residual material (88 of 129 cases). The mean age of the patients was 66 years; there were 62 women and 67 men. ALK gene rearrangement was present in 4% of cytology specimens (3 of 71 specimens) and 7% of surgical specimens (4 of 58 specimens). FISH in 13 cases was technically unsuccessful. Of the 7 FISH-positive cases, only 2 cytology cases (4%) and 2 surgical cases (6%) were found to be positive with the ALK antibody, demonstrating 80% concordance. The one case found to be negative for ALK by IHC demonstrated a variant rearrangement of the ALK 2p23 gene locus by FISH. The results of the current study validate the usefulness of alcohol-fixed and/or formalin-fixed cytology specimens for ALK rearrangement by a novel automated FISH method. IHC using the D5F3 antibody for ALK is specific in this limited cohort. The authors also demonstrated that alcohol-fixed cytology specimens can be used for ALK rearrangement by automated FISH, alone or in conjunction with IHC. © 2014 American Cancer Society.

  6. Test and Diagnosis for Small-Delay Defects

    CERN Document Server

    Tehranipoor, Mohammad; Chakrabarty, Krishnendu

    2012-01-01

    This book introduces new techniques for detecting and diagnosing small-delay defects (SDD) in integrated circuits. Although this sort of timing defect is commonly found in integrated circuits manufactured with nanometer technology, this will be the first book to introduce effective and scalable methodologies for screening and diagnosing small-delay defects, including important parameters such as process variations, crosstalk, and power supply noise. This book presents new techniques and methodologies to improve overall SDD detection with very small pattern sets. These methods can result in pattern counts as low as a traditional 1-detect pattern set and long path sensitization and SDD detection similar to or even better than n-detect or timing-aware pattern sets. The important design parameters and pattern-induced noises such as process variations,power supply noise (PSN) and crosstalk are taken into account in the methodologies presented. A diagnostic flow is also presented to identify whether the failure is ...

  7. Electrothermal Action of the Pulse of the Current of a Short Artificial-Lightning Stroke on Test Specimens of Wires and Cables of Electric Power Objects

    Science.gov (United States)

    Baranov, M. I.; Rudakov, S. V.

    2018-03-01

    The authors have given results of investigations of the electrothermal action of aperiodic pulses of temporal shape 10/350 μs of the current of a short artificial-lightning stroke on test specimens of electric wires and cables with copper and aluminum cores and sheaths with polyvinylchloride and polyethylene insulations of power circuits of industrial electric power objects. It has been shown that the thermal stability of such wires and cables is determined by the action integral of the indicated current pulse. The authors have found the maximum permissible and critical densities of this pulse in copper and aluminum current-carrying parts of the wires and cables. High-current experiments conducted under high-voltage laboratory conditions on a unique generator of 10/350 μs pulses of an artificial-lightning current with amplitude-time parameters normalized according to the existing requirements of international and national standards and with tolerances on them have confirmed the reliability of the proposed calculated estimate for thermal lightning resistance of cabling and wiring products.

  8. Electrothermal Action of the Pulse of the Current of a Short Artificial-Lightning Stroke on Test Specimens of Wires and Cables of Electric Power Objects

    Science.gov (United States)

    Baranov, M. I.; Rudakov, S. V.

    2018-05-01

    The authors have given results of investigations of the electrothermal action of aperiodic pulses of temporal shape 10/350 μs of the current of a short artificial-lightning stroke on test specimens of electric wires and cables with copper and aluminum cores and sheaths with polyvinylchloride and polyethylene insulations of power circuits of industrial electric power objects. It has been shown that the thermal stability of such wires and cables is determined by the action integral of the indicated current pulse. The authors have found the maximum permissible and critical densities of this pulse in copper and aluminum current-carrying parts of the wires and cables. High-current experiments conducted under high-voltage laboratory conditions on a unique generator of 10/350 μs pulses of an artificial-lightning current with amplitude-time parameters normalized according to the existing requirements of international and national standards and with tolerances on them have confirmed the reliability of the proposed calculated estimate for thermal lightning resistance of cabling and wiring products.

  9. The relative performance of bivariate causality tests in small samples

    NARCIS (Netherlands)

    Bult, J..R.; Leeflang, P.S.H.; Wittink, D.R.

    1997-01-01

    Causality tests have been applied to establish directional effects and to reduce the set of potential predictors, For the latter type of application only bivariate tests can be used, In this study we compare bivariate causality tests. Although the problem addressed is general and could benefit

  10. Viscoplastic-dynamic analyses of small-scale fracture tests to obtain crack arrest toughness values for PTS conditions

    International Nuclear Information System (INIS)

    Kanninen, M.F.; Hudak, S.J. Jr; Dexter, R.J.; Couque, H.; O'Donoghue, P.E.; Polch, E.Z.

    1988-01-01

    Reliable predictions of crack arrest at the high upper shelf toughness conditions involved in postulated pressurized thermal shock (PTS) events require procedures beyond those utilized in conventional fracture mechanics treatments. To develop such a procedure, viscoplastic-dynamic fracture mechanics finite element analyses, viscoplastic material characterization testing, and small-scale crack propagation and arrest experimentation are being combines in this research. The approach couples SwRI's viscoplastic-dynamic fracture mechanics finite element code VISCRK with experiments using duplex 4340/A533B steel compact specimens. The experiments are simulated by VISCRK computations employing the Bodner-Partom viscoplastic constitutive relation and the nonlinear fracture mechanics parameter T. The goal is to develop temperature-dependent crack arrest toughness values for A533B steel. While only room temperature K Ia values have been obtained so far, these have been found to agree closely with those obtained from wide plate tests. (author)

  11. Laparoscopic specimen retrieval bags.

    Science.gov (United States)

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  12. Chromogenic culture media or rapid immunochromatographic test: Which is better for detecting Klebsiella pneumoniae that produce OXA-48 and can they be used in blood and urine specimens.

    Science.gov (United States)

    Genc, Ozlem; Aksu, Evrim

    2018-05-01

    Our goal was to compare a rapid test (OXA-48K-SeT) and four different chromogenic media (CHROMagar KPC, CHROMagar mSuperCARBA, ChromID Carba and ChromID OXA-48) for the detection of OXA-48 producing Klebsiella pneumoniae isolates and spiked urine/blood samples with these bacteria. In total 100 K.pneumoniae isolates, including 60 OXA-48 positive, 15 other carbapenemase producing, 15 Extended spectrum betalactamases (ESBL) positive and 10 carbapenem sensitive K.pneumoniae were included in the study. After all samples were inoculated into all chromogenic media, temocillin discs were placed onto the media. OXA-48K-SeT was studied according to the manufacturer's instructions and the lower detection limit was determined. Sensitivities and specificities of all chromogenic media and rapid test were detected as 100%. All of the OXA-48 producers were found resistant to temocillin on all chromogenic media. The lower detection limit of the rapid assay was determined as 10 6 in both direct bacterial samples and in spiked urine/blood samples. As a result, four chromogenic culture media and OXA-48 K-SeT can be used safely for detection of OXA-48 positive K.pneumoniae isolates. Although direct clinical specimens were not used, our study suggests that this media and OXA-48 K-SeT may be used in patient samples like blood and urine. Further studies are needed to assess this suggestion. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. EGFR Mutations in Surgically Resected Fresh Specimens from 697 Consecutive Chinese Patients with Non-Small Cell Lung Cancer and Their Relationships with Clinical Features

    Directory of Open Access Journals (Sweden)

    Yuanyang Lai

    2013-12-01

    Full Text Available We aimed to reveal the true status of epidermal growth factor receptor (EGFR mutations in Chinese patients with non-small cell lung cancer (NSCLC after lung resections. EGFR mutations of surgically resected fresh tumor samples from 697 Chinese NSCLC patients were analyzed by Amplification Refractory Mutation System (ARMS. Correlations between EGFR mutation hotspots and clinical features were also explored. Of the 697 NSCLC patients, 235 (33.7% patients had tyrosine kinase inhibitor (TKIs sensitive EGFR mutations in 41 (14.5% of the 282 squamous carcinomas, 155 (52.9% of the 293 adenocarcinomas, 34 (39.5% of the 86 adenosquamous carcinomas, one (9.1% of the 11 large-cell carcinomas, 2 (11.1% of the 18 sarcomatoid carcinomas, and 2 (28.6% of the 7 mucoepidermoid carcinomas. TKIs sensitive EGFR mutations were more frequently found in female patients (p < 0.001, non-smokers (p = 0.047 and adenocarcinomas (p < 0.001. The rates of exon 19 deletion mutation (19-del, exon 21 L858R point mutation (L858R, exon 21 L861Q point mutation (L861Q, exon 18 G719X point mutations (G719X, including G719C, G719S, G719A were 43.4%, 48.1%, 1.7% and 6.8%, respectively. Exon 20 T790M point mutation (T790M was detected in 3 squamous carcinomas and 3 adenocarcinomas and exon 20 insertion mutation (20-ins was detected in 2 patients with adenocarcinoma. Our results show the rates of EGFR mutations are higher in all types of NSCLC in Chinese patients. 19-del and L858R are two of the more frequent mutations. EGFR mutation detection should be performed as a routine postoperative examination in Chinese NSCLC patients.

  14. Chromogenic In Situ Hybridization and p16/Ki67 Dual Staining on Formalin-Fixed Paraffin-Embedded Cervical Specimens: Correlation with HPV-DNA Test, E6/E7 mRNA Test, and Potential Clinical Applications

    Directory of Open Access Journals (Sweden)

    Roberta Zappacosta

    2013-01-01

    Full Text Available Although HPV-DNA test and E6/E7 mRNA analyses remain the current standard for the confirmation of human papillomavirus (HPV infections in cytological specimens, no universally adopted techniques exist for the detection of HPV in formalin-fixed paraffin-embedded samples. Particularly, in routine laboratories, molecular assays are still time-consuming and would require a high level of expertise. In this study, we investigated the possible use of a novel HPV tyramide-based chromogenic in situ hybridization (CISH technology to locate HPV on tissue specimens. Then, we evaluate the potential usefulness of p16INK4a/Ki-67 double stain on histological samples, to identify cervical cells expressing HPV E6/E7 oncogenes. In our series, CISH showed a clear signal in 95.2% of the specimens and reached a sensitivity of 86.5%. CISH positivity always matched with HPV-DNA positivity, while 100% of cases with punctated signal joined with cervical intraepithelial neoplasia grade 2 or worse (CIN2+. p16/Ki67 immunohistochemistry gave an interpretable result in 100% of the cases. The use of dual stain significantly increased the agreement between pathologists, which reached 100%. Concordance between dual stain and E6/E7 mRNA test was 89%. In our series, both CISH and p16INK4a/Ki67 dual stain demonstrated high grade of performances. In particular, CISH would help to distinguish episomal from integrated HPV, in order to allow conclusions regarding the prognosis of the lesion, while p16INK4a/Ki67 dual stain approach would confer a high level of standardization to the diagnostic procedure.

  15. Chromogenic In Situ Hybridization and p16/Ki67 Dual Staining on Formalin-Fixed Paraffin-Embedded Cervical Specimens: Correlation with HPV-DNA Test, E6/E7 mRNA Test, and Potential Clinical Applications

    Science.gov (United States)

    Zappacosta, Roberta; Colasante, Antonella; Viola, Patrizia; D'Antuono, Tommaso; Lattanzio, Giuseppe; Capanna, Serena; Gatta, Daniela Maria Pia; Rosini, Sandra

    2013-01-01

    Although HPV-DNA test and E6/E7 mRNA analyses remain the current standard for the confirmation of human papillomavirus (HPV) infections in cytological specimens, no universally adopted techniques exist for the detection of HPV in formalin-fixed paraffin-embedded samples. Particularly, in routine laboratories, molecular assays are still time-consuming and would require a high level of expertise. In this study, we investigated the possible use of a novel HPV tyramide-based chromogenic in situ hybridization (CISH) technology to locate HPV on tissue specimens. Then, we evaluate the potential usefulness of p16INK4a/Ki-67 double stain on histological samples, to identify cervical cells expressing HPV E6/E7 oncogenes. In our series, CISH showed a clear signal in 95.2% of the specimens and reached a sensitivity of 86.5%. CISH positivity always matched with HPV-DNA positivity, while 100% of cases with punctated signal joined with cervical intraepithelial neoplasia grade 2 or worse (CIN2+). p16/Ki67 immunohistochemistry gave an interpretable result in 100% of the cases. The use of dual stain significantly increased the agreement between pathologists, which reached 100%. Concordance between dual stain and E6/E7 mRNA test was 89%. In our series, both CISH and p16INK4a/Ki67 dual stain demonstrated high grade of performances. In particular, CISH would help to distinguish episomal from integrated HPV, in order to allow conclusions regarding the prognosis of the lesion, while p16INK4a/Ki67 dual stain approach would confer a high level of standardization to the diagnostic procedure. PMID:24369532

  16. Personalized medicine for non-small-cell lung cancer: implications of recent advances in tissue acquisition for molecular and histologic testing.

    Science.gov (United States)

    Moreira, Andre L; Thornton, Raymond H

    2012-09-01

    In light of recent advances in individualized therapy for non-small-cell lung cancer (NSCLC), molecular and histologic profiling is essential for guiding therapeutic decisions. Results of these analyses may have implications for both response (eg, molecular testing for EGFR [epidermal growth factor receptor] mutations) and safety (eg, contraindications for squamous histology) in NSCLC. Most patients with NSCLC present with unresectable advanced disease; therefore, greater emphasis is being placed on minimally invasive tissue acquisition techniques, such as small biopsy and cytology specimens. Due to the need for increasing histologic and molecular information and increasingly smaller tissue sample sizes, efforts must be focused on optimizing tissue acquisition and the development of more sensitive molecular assays. Recent advances in tissue acquisition techniques and specimen preservation may help to address this challenge and lead to enhanced personalized treatment in NSCLC. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Georeferencing Animal Specimen Datasets

    NARCIS (Netherlands)

    van Erp, M.G.J.; Hensel, R.; Ceolin, D.; van der Meij, M.

    2014-01-01

    For biodiversity research, the field of study that is concerned with the richness of species of our planet, it is of the utmost importance that the location of an animal specimen find is known with high precision. Due to specimens often having been collected over the course of many years, their

  18. Small-scale bentonite injection test on rock

    International Nuclear Information System (INIS)

    Pusch, R.

    1978-03-01

    When radiactive waste is disposed a sealing of the rock is very valuable since it reduces the rate of water percolation and diffusion. In an earlier report injection of bentonite gels by means of over-pressure and subsequent electrophoresis has been suggested. The present report describes a rock test series where bentonite injection was applied. For the test an approximately cubical block of about 1 m 3 was selected. The rock type was diorite with a fairly high frequency of quartz denses. The block was kept in a basin during the test in order to maintain the water saturation. Holes were bored in the block. A bentonite slurry with 1000 percent water content was injected. It was shown that the bentonite had a sealing effect but the depth of extrusion into rock joints was not large because of gelation. Electro-Kinetic injection of montmorillonite was found to be a more promising technique for rock lightening

  19. 76 FR 62044 - Alternative Testing Requirements for Small Batch Manufacturers

    Science.gov (United States)

    2011-10-06

    ... become part of the public record. FOR FURTHER INFORMATION CONTACT: Concerning requests and procedures for... Flammability of Vinyl Plastic Film. 1215 Infant Bath Seats. Sec. 101 of CPSIA (Test Method CPSC-CH- Lead... public hearing will become part of the public record. Access to the docket to read background documents...

  20. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  1. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  2. Small Sample Robust Testing for Normality against Pareto Tails

    Czech Academy of Sciences Publication Activity Database

    Stehlík, M.; Fabián, Zdeněk; Střelec, L.

    2012-01-01

    Roč. 41, č. 7 (2012), s. 1167-1194 ISSN 0361-0918 Grant - others:Aktion(CZ-AT) 51p7, 54p21, 50p14, 54p13 Institutional research plan: CEZ:AV0Z10300504 Keywords : consistency * Hill estimator * t-Hill estimator * location functional * Pareto tail * power comparison * returns * robust tests for normality Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.295, year: 2012

  3. Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test.

    Science.gov (United States)

    Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C

    2010-03-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

  4. The effect of specimen and flaw dimensions on fracture toughness

    Energy Technology Data Exchange (ETDEWEB)

    Nevalainen, M.J. [VTT Manufacturing Technology, Espoo (Finland)

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account. 64 refs. The thesis includes also four previous publications by author.

  5. 77 FR 26607 - Energy Conservation Program: Test Procedures for Electric Motors and Small Electric Motors

    Science.gov (United States)

    2012-05-04

    ... Conservation Program: Test Procedures for Electric Motors and Small Electric Motors; Final Rules #0;#0;Federal... Procedures for Electric Motors and Small Electric Motors AGENCY: Office of Energy Efficiency and Renewable... electric motors and small electric motors. That supplemental proposal, along with an earlier proposal from...

  6. 48 CFR 252.219-7004 - Small business subcontracting plan (test program).

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Small business... AND CONTRACT CLAUSES Text of Provisions And Clauses 252.219-7004 Small business subcontracting plan (test program). As prescribed in 219.708(b)(1)(B), use the following clause: Small Business...

  7. US bureau of mines small-scale arc melter tests

    International Nuclear Information System (INIS)

    O'Connor, W.K.; Oden, L.L.; Turner, P.C.; Davis, D.L.

    1993-01-01

    The US Bureau of Mines, in cooperation with the Idaho National Engineering Laboratory (INEL), conducted over 30 hours of melting tests to vitrify simulated low-level radioactive wastes from the INEL. Radioactive Waste Management Complex (RWMC). Five separate waste compositions were investigated, each consisting of noncontaminated soil from the RWMC and surrogate materials used to simulate the actual buried wastes. The RWMC soil and five waste compositions were melted in a 50-lb, single-phase electric arc furnace with a water-cooled shell. These tests were conducted to determine melting parameters in preparation for a large-scale melting campaign to be conducted in the Bureau's 1-metric ton (mt), water-cooled-wall, 3-phase electric arc furnace. Bulk chemical composition was determined for each of the feed materials and for the slag, metal, fume solids, and offgas furnace products, and distributions were calculated for the key elements. The material balance for the furnace operation indicates that from 63 to 84 pct of the feed reported to the slag. Cerium, used as the surrogate for the radionuclides in the wastes, demonstrated an extremely strong affinity for the slag product. Although slag temperatures as low as 1,250 C were recorded when melting the RWMC soil, temperatures in excess of 1,600 C were necessary to achieve the fluidity required for a successful slag tap

  8. Eddy Current Testing for Detecting Small Defects in Thin Films

    Science.gov (United States)

    Obeid, Simon; Tranjan, Farid M.; Dogaru, Teodor

    2007-03-01

    Presented here is a technique of using Eddy Current based Giant Magneto-Resistance sensor (GMR) to detect surface and sub-layered minute defects in thin films. For surface crack detection, a measurement was performed on a copper metallization of 5-10 microns thick. It was done by scanning the GMR sensor on the surface of the wafer that had two scratches of 0.2 mm, and 2.5 mm in length respectively. In another experiment, metal coatings were deposited over the layers containing five defects with known lengths such that the defects were invisible from the surface. The limit of detection (resolution), in terms of defect size, of the GMR high-resolution Eddy Current probe was studied using this sample. Applications of Eddy Current testing include detecting defects in thin film metallic layers, and quality control of metallization layers on silicon wafers for integrated circuits manufacturing.

  9. Test of a small domestic boiler using different pellets

    International Nuclear Information System (INIS)

    Dias, J.; Costa, M.; Azevedo, J.L.T.

    2004-01-01

    This paper presents results from an experimental study performed on a 13 kW th commercial domestic boiler using pellets as fuel. Four different types of pellets were used and, for each one, the boiler was tested as a function of its capacity and the fan regulation affecting excess air. Measurements were performed for boiler heat load, pellet consumption rate, flue-gas temperature and composition. Mass balances allowed the calculation of the flue-gas flow rate and associated heat losses. Losses from incomplete combustion have also been quantified. Under boiler steady-state conditions the flue-gas O 2 concentration changes with boiler load and ventilation due to the regulation scheme of the boiler. Flue-gas CO shows a minimum for values of O 2 in the flue-gases of about 13%. NO x emissions are independent of excess air for low values of nitrogen in the fuel whereas, for larger values, NO x emissions increase with the O 2 present in the combustion products. The fractional conversion of the pellet nitrogen into NO x is in line with literature data. The boiler start-up was characterised by the temperature evolution inside and above the bed showing the propagation of combustion in the bed during about 10 min. During boiler start-up, a maximum in CO emissions was observed which is associated with the maximum combustion intensity, as typified by the flue-gas O 2 concentration and temperature, regardless the pellet type. (Author)

  10. Use of precracked Charpy and smaller specimens to establish the master curve

    International Nuclear Information System (INIS)

    Sokolov, M.A.; McCabe, D.E.; Nanstad, R.K.; Davidov, Y.A.

    1997-01-01

    The current provisions used in the U.S. Code of Federal Regulations for the determination of the fracture toughness of reactor pressure vessel steels employs an assumption that there is a direct correlation between K Ic lower-bound toughness and the Charpy V-notch transition curve. Such correlations are subject to scatter from both approaches which weakens the reliability of fracture mechanics-based analyses. In this study, precracked Charpy and smaller size specimens are used in three-point static bend testing to develop fracture mechanics based K k values. The testing is performed under carefully controlled conditions such that the values can be used to predict the fracture toughness performance of large specimens. The concept of a universal transition curve (master curve) is applied. Data scatter that is characteristic of commercial grade steels and their weldments is handled by Weibull statistical modeling. The master curve is developed to describe the median K Jc fracture toughness for 1T size compact specimens. Size effects are modeled using weakest-link theory and are studied for different specimen geometries. It is shown that precracked Charpy specimens when tested within their confined validity limits follow the weakest-link size-adjustment trend and predict the fracture toughness of larger specimens. Specimens of smaller than Charpy sizes (5 mm thick) exhibit some disparities in results relative to weakest-link size adjustment prediction suggesting that application of such adjustment to very small specimens may have some limitations

  11. Formation of Gaps at the Specimen-Bar Interfaces in Numerical Simulations of Compression Hopkinson Bar Tests on Soft, Nearly Incompressible Materials

    Science.gov (United States)

    2010-09-01

    MISSISSIPPI MECHANICAL ENGINEERING A RAJENDRAN 201 CARRIER HALL UNIVERSITY MS 38677 2 UNIVERSITY OF CALIFORNIA SAN DIEGO ...extrapolation of the data given in Aihaiti and Hemley (10); the authors attribute this data to Dana Dattlebaum at Los Alamos National Laboratory...region bordering the centerline, about 6–8 specimen lengths back from the S-IB interface. From 164.2 to164.6 s (figures 19 and 20), the pressure

  12. The relative test performance characteristics of two commercial assays for the detection of Mycobacterium tuberculosis complex in paraffin-fixed human biopsy specimens

    Directory of Open Access Journals (Sweden)

    Broukhanski George

    2008-09-01

    Full Text Available Abstract The Seeplex™ TB Detection-2 assay (Rockville, MD is a nested endpoint PCR for the Mycobacterium tuberculosis complex (MTBC targets IS6110 and MPB64 that utilizes dual priming oligonucleotide technology. When used to detect the presence of MTBC DNA in formalin-fixed paraffin-embedded tissue specimens, the sensitivity and specificity of this assay is equivalent to a labor-intensive traditional endpoint PCR assay and is more sensitive than a commercial real-time PCR assay.

  13. Evaluation of ductile-brittle transition behavior with neutron irradiation in nuclear reactor pressure vessel steels using small punch test

    International Nuclear Information System (INIS)

    Kim, M. C.; Lee, B. S.; Oh, Y. J.

    2003-01-01

    A Small Punch (SP) test was performed to evaluate the ductile-brittle transition temperature before and after neutron irradiation in Reactor Pressure Vessel (RPV) steels produced by different manufacturing (refining) processes. The results were compared to the standard transition temperature shifts from the Charpy test and Master Curve fracture toughness test in accordance with the ASTM standard E1921. The samples were taken from 1/4t location of the vessel thickness and machined into a 10x10x0.5mm dimension. Irradiation of the samples was carried out in the research reactor at KAERI (HANARO) at about 290 .deg. C of the different fluence levels respectively. SP tests were performed in the temperature range of RT to -196 .deg. C using a 2.4mm diameter ball. For the materials before and after irradiation, SP transition temperatures (T sp ), which are determined at the middle of the upper and lower SP energies, showed a linear correlation with the Charpy index temperature, T 41J . T sp from the irradiated samples was increased as the fluence level increased and was well within the deviation range of the unirradiated data. The TSP had a correlation with the reference temperature (T 0 ) from the master curve method using a pre-cracked Charpy V-notched (PCVN) specimen

  14. Specimen size effect considerations for irradiation studies of SiC/SiC

    Energy Technology Data Exchange (ETDEWEB)

    Youngblood, G.E.; Henager, C.H. Jr.; Jones, R.H. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-10-01

    For characterization of the irradiation performance of SiC/SiC, limited available irradiation volume generally dictates that tests be conducted on a small number of relatively small specimens. Flexure testing of two groups of bars with different sizes cut from the same SiC/SiC plate suggested the following lower limits for flexure specimen number and size: Six samples at a minimum for each condition and a minimum bar size of 30 x 6.0 x 2.0 mm{sup 3}.

  15. A minimal molecular toolkit for mineral deposition? Biochemistry and proteomics of the test matrix of adult specimens of the sea urchin Paracentrotus lividus.

    Science.gov (United States)

    Karakostis, Konstantinos; Zanella-Cléon, Isabelle; Immel, Françoise; Guichard, Nathalie; Dru, Philippe; Lepage, Thierry; Plasseraud, Laurent; Matranga, Valeria; Marin, Frédéric

    2016-03-16

    The sea urchin endoskeleton consists of a magnesium-rich biocalcite comprising a small amount of occluded organic macromolecules. This structure constitutes a key-model for understanding the mineral--organics interplay, and for conceiving in vitro bio-inspired materials with tailored properties. Here we employed a deep-clean technique to purify the occluded proteins from adult Paracentrotus lividus tests. We characterized them by 1- and 2D-electrophoreses, ELISA and immunoblotting, and using liquid chromatography coupled with Mass Spectrometry (nanoLC-MS/MS), we identified two metalloenzymes (carbonic anhydrase and MMP), a set of MSP130 family members, several C-type lectins (SM29, SM41, PM27) and cytoskeletal proteins. We demonstrate the effect of the protein extract on the crystals, with an in vitro crystallization assay. We suggest that this small set of biomineralization proteins may represent a 'minimal molecular crystallization toolkit'. Biominerals often exhibit superior chemical properties, when compared to their inorganic counterparts. This is due pro parte to the proteins that are occluded in the mineral. However, the limited available studies on biomineralization have not yet succeeded in identifying a minimal set of proteins directly involved in the formation of the biomineral in vivo and sufficiently required for in vitro precipitation. Indeed, the high number of proteins identified by high-throughput screening in the recent years does not encourage the possibility of recreating or tailoring the mineral in vitro. Thus, the identification of biomineralization proteins involved in protein-mineral interactions is highly awaited. In the present study, we used the sea urchin, Paracentrotus lividus (P. lividus), to identify the native proteins directly taking part in protein-mineral interactions. We employed an improved deep-clean technique to extract and purify the native occluded skeletal matrix proteins from the test and identified them by the highly

  16. Controlled Environment Specimen Transfer

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  17. Miniaturized fatigue crack growth specimen technology and results

    International Nuclear Information System (INIS)

    Puigh, R.J.; Bauer, R.E.; Ermi, A.M.; Chin, B.A.

    1981-01-01

    The miniature fatigue crack propagation technology has been extended to in-cell fabrication of irradiated specimens. Baseline testing of selected titanium alloys has been performed at 25 0 C in air. At relatively small values for the stress intensity factor, ΔK, the crack growth rates for all titanium alloys investigated are within a factor of three. The crack growth rates for these titanium alloys are a factor of three greater than the crack growth rates of either 316SS (20% CW) or HT-9. Each of the titanium alloys has observable crack propagation for stress intensity factors as small as 4.2 MPa√m

  18. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    Science.gov (United States)

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. General Mechanical Repair. Minor Automotive Maintenance, Small Engine [Repair, and] Welding: Competency Test Package.

    Science.gov (United States)

    Hamlin, Larry

    This document contains the competency test package for three sections of a general mechanical repair course: minor automotive maintenance, small engine mechanics, and welding. Following a list of the common essential elements for trade and industrial education, competency tests for the three sections are provided. Each test includes unit name,…

  20. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  1. Small scale heater tests in argillite of the Eleana Formation at the Nevada Test Site

    International Nuclear Information System (INIS)

    McVey, D.F.; Thomas, R.K.; Lappin, A.R.

    1979-11-01

    Near-surface heater tests were run in the Eleana Formation at the Nevada Test Site, in an effort to evaluate argillaceous rock for nuclear waste storage. The main test, which employed a full-scale heater with a thermal output approximating commercial borosilicate waste, was designed to operate for several months. Two smaller, scaled tests were run prior to the full-scale test. This report develops the thermal scaling laws, describes the pretest thermal and thermomechanical analysis conducted for these two tests, and discusses the material properties data used in the analyses. In the first test, scaled to a large heater of 3.5 kW power, computed heater temperatures were within 7% of measured values for the entire 96-hour test run. The second test, scaled to a large heater having 5.0 kW power, experienced periodic water in-flow onto the heater, which tended to damp the temperature. For the second test, the computed temperatures were within 7% of measured for the first 20 hours. After this time, the water effect became significant and the measured temperatures were 15 to 20% below those predicted. On the second test, rock surface spallation was noted in the bore hole above the heater, as predicted. The scaled tests indicated that in-situ argillite would not undergo major thermostructural failure during the follow-on, 3.5 kW, full-scale test. 24 figures, 6 tables

  2. Analysis of potential factors influencing the relation between small punch and conventional creep test

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr; Milička, Karel; Dobeš, Ferdinand

    2010-01-01

    Roč. 63, Spp. Issue (2010), s. 50-53 ISSN 0018-8069. [International Conference "Determination of Mechanical Properties of Materials by Small Punch and Other Miniature testing Techniques" /1./. Ostrava, 31.08.2010-02.09.2010] R&D Projects: GA AV ČR(CZ) IAA200410801 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * small punch test * chromium steel Subject RIV: JG - Metallurgy

  3. Application of Small Punch Test for Estimation of Fracture Properties of Fe-Al Alloys

    Czech Academy of Sciences Publication Activity Database

    Dobeš, Ferdinand; Milička, Karel

    2010-01-01

    Roč. 63, Sp. Iss. (2010), s. 83-86 ISSN 0018-8069. [Determination of Mechanical Properties of Materials by Small Punch and Other Miniature Testing Techniques/1./. Ostrava, 31.08.2010-02.09.2010] R&D Projects: GA ČR GA106/08/1238 Institutional research plan: CEZ:AV0Z20410507 Keywords : small punch test * ductility * iron aluminides Subject RIV: JG - Metallurgy

  4. Precracking of WC-Co-hardmetal-specimens for fracture-toughness testing. Anrisserzeugung in WC-Co-Hartmetall-Proben fuer die Messung des kritischen Spannungsintensitaetsfaktors K sub IC

    Energy Technology Data Exchange (ETDEWEB)

    Wissmeier, H.J.; Engel, U. (Erlangen-Nuernberg Univ., Erlangen (Germany, F.R.). Lehrstuhl fuer Fertigungstechnologie)

    1989-09-01

    The determination of a valid critical stress intensity factor K{sub IC} requires an extremely sharp, well defined initial crack. Methods producing such a crack are well known for metallic materials, but they often can not be used with brittle materials, like cemented carbides or ceramics. Their low fracture toughness makes a controlled crack growth under pure tensile stress nearly impossible. More useful are precracking methods, utilizing a stress gradient to stop the crack at defined depth. A very simple method uses the indentation of a hardness tester to produce a semi-elliptical surface crack, interfered with residual stresses. For different areas of application and specimen geometries, bridge indentation, wedge indentation and composite bending method produce cracks with a straight front. Also under cyclic loading, under tensile as well as under compressive stress, the creation of a sharp precrack, applicable in K{sub IC} measurement, is possible. (orig.).

  5. Atomistic Simulations of Small-scale Materials Tests of Nuclear Materials

    International Nuclear Information System (INIS)

    Shin, Chan Sun; Jin, Hyung Ha; Kwon, Jun Hyun

    2012-01-01

    Degradation of materials properties under neutron irradiation is one of the key issues affecting the lifetime of nuclear reactors. Evaluating the property changes of materials due to irradiations and understanding the role of microstructural changes on mechanical properties are required for ensuring reliable and safe operation of a nuclear reactor. However, high dose of neuron irradiation capabilities are rather limited and it is difficult to discriminate various factors affecting the property changes of materials. Ion beam irradiation can be used to investigate radiation damage to materials in a controlled way, but has the main limitation of small penetration depth in the length scale of micro meters. Over the past decade, the interest in the investigations of size-dependent mechanical properties has promoted the development of various small-scale materials tests, e.g. nanoindentation and micro/nano-pillar compression tests. Small-scale materials tests can address the issue of the limitation of small penetration depth of ion irradiation. In this paper, we present small-scale materials tests (experiments and simulation) which are applied to study the size and irradiation effects on mechanical properties. We have performed molecular dynamics simulations of nanoindentation and nanopillar compression tests. These atomistic simulations are expected to significantly contribute to the investigation of the fundamental deformation mechanism of small scale irradiated materials

  6. Assessment of Current Practice for Tank Testing of Small Marine Energy Devices

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    Discussion Report. Equitable Testing and Evaluation of Marine Energy Extraction Devices in terms of Performance, Cost and Environmental Impact. The report is a contribution by Aalborg University (AAU) to the deliverable on Assessment of current practice for tank testing of small marine energy...

  7. THE SMALL BUT SIGNIFICANT AND NONTRANSITORY INCREASE IN PRICES (SSNIP TEST

    Directory of Open Access Journals (Sweden)

    Liviana Niminet

    2008-12-01

    Full Text Available The Small but Significant Nontransitory Increase in Price Test was designed to define the relevant market by concepts of product, geographical area and time. This test, also called the ,,hypothetical monopolistic test” is the subject of many researches both economical and legal as it deals with economic concepts as well as with legally aspects.

  8. Energetic Materials Center Report--Small-Scale Safety and Thermal Testing Evaluation of Butyl Nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Energetic Materials Center; Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Energetic Materials Center

    2013-04-26

    Butyl Nitrate (BN) was examined by Small-Scale Safety and Thermal (SSST) Testing techniques to determine its sensitivity to impact, friction, spark and thermal exposure simulating handling and storage conditions. Under the conditions tested, the BN exhibits thermal sensitivity above 150 °C, and does not exhibit sensitive to impact, friction or spark.

  9. NASA Biological Specimen Repository

    Science.gov (United States)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  10. Testing and data reduction of the Chinese Small Telescope Array (CSTAR) for Dome A, Antarctica

    International Nuclear Information System (INIS)

    Zhou Xu; Wu Zhenyu; Jiang Zhaoji; Hu Jingyao; Li Qisheng; Ma Jun; Wang Jiali; Wu Jianghua; Yan Jun; Cui Xiangqun; Gong Xuefei; Liu Genrong; Xia Lirong; Yuan Xiangyan; Zhai Fengxiang; Zhang Ru; Feng Longlong; Wang Lifan; Zhu Zhenxi

    2010-01-01

    The Chinese Small Telescope Array (CSTAR) is the first Chinese astronomical instrument on the Antarctic ice cap. The low temperature and low pressure testing of the data acquisition system was carried out in a laboratory refrigerator and on the 4500 m Pamirs high plateau, respectively. The results from the final four nights of test observations demonstrated that CSTAR was ready for operation at Dome A, Antarctica. In this paper, we present a description of CSTAR and the performance derived from the test observations.

  11. Rotating specimen rack repair

    International Nuclear Information System (INIS)

    Miller, G.E.; Rogers, P.J.; Nabor, W.G.; Bair, H.

    1984-01-01

    In 1980, an operator at the UCI TRIGA Reactor noticed difficulties with the rotation of the specimen rack. Investigations showed that the drive bearing in the rack had failed and allowed the bearings to enter the rack. After some time of operation in static mode it was decided that installation of a bearing substitute - a graphite sleeve - would be undertaken. Procedures were written and approved for removal of the rack, fabrication and installation of the sleeve, and re-installation of the rack. This paper describes these procedures in some detail. Detailed drawings of the necessary parts may be obtained from the authors

  12. Method for thinning specimen

    Science.gov (United States)

    Follstaedt, David M.; Moran, Michael P.

    2005-03-15

    A method for thinning (such as in grinding and polishing) a material surface using an instrument means for moving an article with a discontinuous surface with an abrasive material dispersed between the material surface and the discontinuous surface where the discontinuous surface of the moving article provides an efficient means for maintaining contact of the abrasive with the material surface. When used to dimple specimens for microscopy analysis, a wheel with a surface that has been modified to produce a uniform or random discontinuous surface significantly improves the speed of the dimpling process without loss of quality of finish.

  13. Test of a sample container for shipment of small size plutonium samples with PAT-2

    International Nuclear Information System (INIS)

    Kuhn, E.; Aigner, H.; Deron, S.

    1981-11-01

    A light-weight container for the air transport of plutonium, to be designated PAT-2, has been developed in the USA and is presently undergoing licensing. The very limited effective space for bearing plutonium required the design of small size sample canisters to meet the needs of international safeguards for the shipment of plutonium samples. The applicability of a small canister for the sampling of small size powder and solution samples has been tested in an intralaboratory experiment. The results of the experiment, based on the concept of pre-weighed samples, show that the tested canister can successfully be used for the sampling of small size PuO 2 -powder samples of homogeneous source material, as well as for dried aliquands of plutonium nitrate solutions. (author)

  14. Small-Scale Quasi-Static Tests on Non-Slender Piles Situated in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo

    In the period from February 2009 till March 2011 a series of small-scale tests on pile foundations has been conducted at Aalborg University. In all the tests the piles have been exposed to quasi-static loading and all the tests have been conducted in a pressure tank. The objective of the tests has...... been to investigate the effect of pile diameter and length to diameter ratio on the soil response in sand for non-slender piles. Further, the tests have been conducted to calibrate a three-dimensional numerical model in the commercial program FLAC3D....

  15. RQ-21A Blackjack Small Tactical Unmanned Aircraft System (STUAS): Initial Operational Test and Evaluation Report

    Science.gov (United States)

    2015-06-29

    Evaluation Report June 2015 This report on the RQ-21A Blackjack Small Tactical Unmanned Aircraft System fulfills the provisions of Title 10...suitability of the RQ-21A Blackjack Small Tactical Unmanned Aircraft System (STUAS) during Initial Operational Test and Evaluation (IOT&E). The Navy’s...66.9 percent). The average service life of the propulsion modules was 48.9 hours, which does not meet the manufacturer’s stated 100-hour

  16. Human papillomavirus detection using the Abbott RealTime high-risk HPV tests compared with conventional nested PCR coupled to high-throughput sequencing of amplification products in cervical smear specimens from a Gabonese female population.

    Science.gov (United States)

    Moussavou-Boundzanga, Pamela; Koumakpayi, Ismaël Hervé; Labouba, Ingrid; Leroy, Eric M; Belembaogo, Ernest; Berthet, Nicolas

    2017-12-21

    Cervical cancer is the fourth most common malignancy in women worldwide. However, screening with human papillomavirus (HPV) molecular tests holds promise for reducing cervical cancer incidence and mortality in low- and middle-income countries. The performance of the Abbott RealTime High-Risk HPV test (AbRT) was evaluated in 83 cervical smear specimens and compared with a conventional nested PCR coupled to high-throughput sequencing (HTS) to identify the amplicons. The AbRT assay detected at least one HPV genotype in 44.57% of women regardless of the grade of cervical abnormalities. Except for one case, good concordance was observed for the genotypes detected with the AbRT assay in the high-risk HPV category determined with HTS of the amplicon generated by conventional nested PCR. The AbRT test is an easy and reliable molecular tool and was as sensitive as conventional nested PCR in cervical smear specimens for detection HPVs associated with high-grade lesions. Moreover, sequencing amplicons using an HTS approach effectively identified the genotype of the hrHPV identified with the AbRT test.

  17. Size effect studies on smooth tensile specimens at room temperature and 400 oC

    International Nuclear Information System (INIS)

    Krompholz, K.; Kamber, J.; Groth, E.; Kalkhof, D.

    2000-06-01

    One of the objectives of the REVISA project (REactor Vessel Integrity in Severe Accidents) is to assess the size effect related to deformation and failure models as well as material data under quasistatic and dynamic conditions in homogeneous and non-homogeneous states of strain. For these investigations the reactor pressure vessel material 20 MnMoNi 55 was selected. It was subjected to a size effect study on smooth scaled tensile specimens of three sizes. Two strain rates (2*10 -5 /s and 10 -3 /s) and two temperatures (room temperature and 400 o C) were selected. The investigations are aimed at a support for a gradient plasticity approach to size effects. Test on the small specimens (diameters 3 and 9 mm) were performed at an electromechanical test machine, while the large specimens (diameter 30 mm) had to be tested at a servohydraulical closed loop test machine with a force capacity of 1000 kN

  18. Size effect studies on smooth tensile specimens at room temperature and 400 {sup o}C

    Energy Technology Data Exchange (ETDEWEB)

    Krompholz, K.; Kamber, J.; Groth, E.; Kalkhof, D

    2000-06-15

    One of the objectives of the REVISA project (REactor Vessel Integrity in Severe Accidents) is to assess the size effect related to deformation and failure models as well as material data under quasistatic and dynamic conditions in homogeneous and non-homogeneous states of strain. For these investigations the reactor pressure vessel material 20 MnMoNi 55 was selected. It was subjected to a size effect study on smooth scaled tensile specimens of three sizes. Two strain rates (2*10{sup -5}/s and 10{sup -3}/s) and two temperatures (room temperature and 400 {sup o}C) were selected. The investigations are aimed at a support for a gradient plasticity approach to size effects. Test on the small specimens (diameters 3 and 9 mm) were performed at an electromechanical test machine, while the large specimens (diameter 30 mm) had to be tested at a servohydraulical closed loop test machine with a force capacity of 1000 kN.

  19. Feature test report for the Small Debris Collection and Packaging System

    International Nuclear Information System (INIS)

    Brisbin, S.A.

    1995-01-01

    The Spent Nuclear Fuel Equipment Engineering group performed feature testing of the Small Debris Collection and Packaging System (SDCPS) in the 305 Cold Test Facility from January 30, 1995, to February 1, 1995. Feature testing of the Small Debris Collection and Packaging System (SDCPS) was performed for the following reasons: To assess the feasibility of using ''drop-out'' vessels to collect small debris (<2.5 cm) in MK-II fuel canisters while transferring sludge to the Weasel Pit. To evaluate system performance under conditions similar to those in the K-Basins (e.g. submerged under 4.9 meters of water and operated with long handled tools) while using a surrogate sludge mixed with debris. To determine if canister weight could be used to predict the volume of sludge and/or debris contained within the canisters during system operation

  20. ITER baffle module small-scale mock-ups: first wall thermo-mechanical testing results

    International Nuclear Information System (INIS)

    Severi, Y.; Giancarli, L.; Poitevin, Y.; Salavy, J.F.; Le Marois, G.; Roedig, M.; Vieider, G.

    1998-01-01

    The EU-home team is in charge of the R and D related to the ITER baffle first wall. Five small-scale mock-ups, using Be, CFC and W tiles and different armour/heat-sink material joints under development, have been fabricated and thermomechanically tested in FE200 (Le Creusot) and JUDITH (Juelich) electron beam facilities. The small-scale mock-ups have been submitted to thermo-mechanical fatigue tests (up to failure using accelerating techniques). The objective was to determine the performances of the armour material joints under high heat flux cycles. (orig.)

  1. Influence of specimen design on the deformation and failure of zircaloy cladding

    International Nuclear Information System (INIS)

    Bates, D.W.; Koss, D.A.; Motta, A.T.; Majumdar, S.

    2000-01-01

    Experimental as well as computational analyses have been used to examine the deformation and failure behavior of ring-stretch specimens of Zircaloy-4 cladding tubes. The results show that, at least for plastically anisotropic unirradiated cladding, specimens with a small gauge length l to width w ratio (l/w ∼ 1) exhibit pronounced non-uniform deformation along their length. As a result, specimen necking occurs upon yielding when the specimen is fully plastic. Finite element analysis indicates a minimum l/w of 4 before a significant fraction of the gauge length deforms homogeneously. A brief examination of the contrasting deformation and failure behavior between uniaxial and plane-strain ring tension tests further supports the use of the latter geometry for determining cladding failure ductility data that are relevant to certain reactivity-initiated accident conditions

  2. A numerical study of two different specimen fixtures for the modified compact tension test – their influence on concrete fracture parameters

    Czech Academy of Sciences Publication Activity Database

    Holušová, Táňa; Seitl, Stanislav; Cifuentes, H.; Canteli, A.

    2016-01-01

    Roč. 10, č. 35 (2016), s. 242-249 ISSN 1971-8993 Institutional support: RVO:68081723 Keywords : Modified Compact Tension Test * Fracture Parameters * Cementitious Composites * FEM Subject RIV: JL - Materials Fatigue, Friction Mechanics

  3. Application of the small punch test to determine the fatigue properties of additive manufactured aerospace alloys

    Directory of Open Access Journals (Sweden)

    Lancaster Robert

    2018-01-01

    Full Text Available Additive layer manufacturing (ALM processes are becoming increasingly prevalent in the aerospace industry as design engineers look to profit from the numerous advantages that these advanced techniques can offer. However, given the safety critical nature and arduous operating conditions to which these components will be exposed to whilst in service, it is essential that the mechanical properties of such structures are fully understood. Transient microstructures are a typical characteristic of ALM components and resulting from the thermal cycles that occur during the build operation. Those microstructures make any mechanical assessment an involved procedure when assessing the process variables for any given parameter set. A useful mechanical test technique is small-scale testing, in particular, the small punch (SP test. SP testing is capable of localised sampling of a larger scale component and presents an attractive option to mechanically assess complex parts with representative geometries, that would not be possible using more conventional uniaxial test approaches. This paper will present the recent development of a small-scale testing methodology capable of inducing fatigue damage and a series of novel tests performed on different variants of Ti-6Al-4V.

  4. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh

    Directory of Open Access Journals (Sweden)

    Kostera J

    2018-05-01

    Full Text Available Joshua Kostera, Gregor Leckie, Klara Abravaya, Hong Wang Abbott Molecular, Abbott Laboratories, Des Plaines, IL, USA Introduction: The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH is an assay for the detection of rifampicin (RIF- and/or isoniazid (INH-resistant Mycobacterium tuberculosis (MTB. The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. Methods: In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. Results: The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert, and MTBDR plus (Hain. RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. Conclusion: The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis. Keywords: tuberculosis, rifampicin, isoniazid, resistance

  5. Small-Scale Cyclic Tests on Nonslender Piles Situated in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo

    In the period from August 2011 till October 2011 a series of small-scale tests on pile foundations has been conducted at Aalborg University. In all the tests, the piles have been exposed to cyclic loading consisting of 20-25 load cycles and all the tests have been conducted in a pressure tank....... The objective of the tests has been to investigate the effect of pile diameter, length to diameter ratio and cyclic loading on the soil response for non-slender piles in sand....

  6. MIMO OTA Testing in Small Multi-Probe Anechoic Chamber Setups

    DEFF Research Database (Denmark)

    Llorente, Ines Carton; Fan, Wei; Pedersen, Gert F.

    2016-01-01

    OTA testing of MIMO capable terminals is often performed in large anechoic chambers, where planar waves impinging the test area are assumed. Furthermore, reflections from the chamber, and probe coupling are often considered negligible due to the large dimensions of the chamber. This paper...... investigates the feasibility of reducing the physical dimension of 2D multi-probe anechoic chamber setups for MIMO OTA testing, with the purpose of reducing the cost and space of the setup. In the paper, a channel emulation algorithm and chamber compensation technique are proposed for MIMO OTA testing in small...... anechoic chambers. The performance deterioration in a small anechoic chamber, i.e., with a ring radius of 0.5 m, is demonstrated via simulations....

  7. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  8. Population-based Neisseria gonorrhoeae, Chlamydia trachomatis and Trichomonas vaginalis Prevalence Using Discarded, Deidentified Urine Specimens Previously Collected for Drug Testing (Open Access Publisher’s Version)

    Science.gov (United States)

    2017-10-24

    trichomonas vaginalis testing, Melinda Balansay-ames, chris Myers and gary Brice for Pcr- based sex determination testing, and Kimberly De Vera for...2017-053355 rEFErEnCEs 1 torrone e , Papp J, Weinstock H. centers for Disease control and Prevention (cDc). Prevalence of Chlamydia trachomatis genital...infection among persons aged 14-39 years-United States, 2007-2012. MMWR Morb Mortal Wkly Rep 2014;63:834–7. 2 rietmeijer ca, Hopkins e , geisler WM

  9. Aggressive chemical decontamination tests on small valves from the Garigliano BWR

    International Nuclear Information System (INIS)

    Bregani, F.

    1990-01-01

    In order to check the effectiveness of direct chemical decontamination on small and complex components, usually considered for storage without decontamination because of the small amount, some tests were performed on the DECO experimental loop. Four small stainless steel valves from the primary system of the Garigliano BWR were decontaminated using mainly aggressive chemicals such as HC1, HF, HNO 3 and their mixtures. On two valves, before the treatment with aggressive chemicals, a step with soft chemical (oxalic and citric acid mixture) was performed in order to see whether a softening action enhances the following aggressive decontamination. Moreover, in order to increase as much as possible the decontamination effectiveness, a decontamination process using ultrasounds jointly with aggressive chemicals was investigated. After an intensive laboratory testing programme, two smaller stainless steel valves from the primary system of the Garigliano BWR were decontaminated using ultrasounds in aggressive chemical solutions

  10. Short term creep small punch testing of P91 and P92 steels,

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr

    2011-01-01

    Roč. 465, - (2011), s. 179-182 ISSN 1013-9826. [Materials Structure & Micromechanics of Fracture 6. Brno, 28.6.2010-30.6,2010] R&D Projects: GA AV ČR(CZ) IAA200410801 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * small punch test * chromium steel Subject RIV: JG - Metallurgy

  11. Effect of specimen size on the fracture toughness of Type 304 stainless steel. Interim report

    International Nuclear Information System (INIS)

    Mills, W.J.

    1982-02-01

    The effect of specimen size on the elastic-plastic fracture toughness behavior of Type 304 stainless steel was characterized by the multiple-specimen J-R curve technique at 427 0 C. Fracture tests were performed on five compact specimen sizes: 2.5T (thickness = 63.5 mm), 2.5T (thickness = 14.7 mm), 1T (thickness = 25.4 mm), 1T (thickness = 14.7 mm), and 0.577 (thickness = 14.7 mm). In comparison with the 63.5-mm thick 2.5T specimen results, the smaller specimens exhibited higher J/sub Ic values and lower R-curve slopes (dJ/da). However, the differences in J/sub Ic/ and dJ/da were not statistically significant for the 2.5T and 1T specimens, which suggests that size effects for 1T and larger specimens are relatively small or nonexistant. On the other hand, there was a statistical difference between the 0.577T and 2.5T J/sub Ic/ values

  12. Evaluation of the NanoCHIP® Gastrointestinal Panel (GIP Test for Simultaneous Detection of Parasitic and Bacterial Enteric Pathogens in Fecal Specimens.

    Directory of Open Access Journals (Sweden)

    Shifra Ken Dror

    Full Text Available Infectious gastroenteritis is a global health problem associated with high morbidity and mortality rates. Rapid and accurate diagnosis is crucial to allow appropriate and timely treatment. Current laboratory stool testing has a long turnaround time (TAT and demands highly qualified personnel and multiple techniques. The need for high throughput and the number of possible enteric pathogens compels the implementation of a molecular approach which uses multiplex technology, without compromising performance requirements. In this work we evaluated the feasibility of the NanoCHIP® Gastrointestinal Panel (GIP (Savyon Diagnostics, Ashdod, IL, a molecular microarray-based screening test, to be used in the routine workflow of our laboratory, a big outpatient microbiology laboratory. The NanoCHIP® GIP test provides simultaneous detection of nine major enteric bacteria and parasites: Campylobacter spp., Salmonella spp., Shigella spp., Giardia sp., Cryptosporidium spp., Entamoeba histolytica, Entamoeba dispar, Dientamoeba fragilis, and Blastocystis spp. The required high-throughput was obtained by the NanoCHIP® detection system together with the MagNA Pure 96 DNA purification system (Roche Diagnostics Ltd., Switzerland. This combined system has demonstrated a higher sensitivity and detection yield compared to the conventional methods in both, retrospective and prospective samples. The identification of multiple parasites and bacteria in a single test also enabled increased efficiency of detecting mixed infections, as well as reduced hands-on time and work load. In conclusion, the combination of these two automated systems is a proper response to the laboratory needs in terms of improving laboratory workflow, turn-around-time, minimizing human errors and can be efficiently integrated in the routine work of the laboratory.

  13. Small-Scale Testing Rig for Long-Term Cyclically Loaded Monopiles in Cohesionless Soil

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2012-01-01

    , and the period of the cyclic loading. However, the design guidance on these issues is limited. Thus, in order to investigate the pile behaviour for cyclically long-term loaded monopiles, a test setup for small-scale tests in saturated dense cohesionless soil is constructed and presented in here. The cyclic...... loading is applied mechanically by means of a testing rig, where the important input parameters: mean level, amplitude, number of cycles, and period of the loading can be varied. The results from a monotonic and a cyclic loading test on an open-ended aluminium pile with diameter = 100 mm and embedded...... length = 600 mm proves that the test setup is capable of applying the cyclic long-term loading. The plastic deformations during loading depend not only on the loading applied but also of the relative density of the soil and, thus, the tests are carried out with relative densities of 77-88%, i.e. similar...

  14. A Third Moment Adjusted Test Statistic for Small Sample Factor Analysis.

    Science.gov (United States)

    Lin, Johnny; Bentler, Peter M

    2012-01-01

    Goodness of fit testing in factor analysis is based on the assumption that the test statistic is asymptotically chi-square; but this property may not hold in small samples even when the factors and errors are normally distributed in the population. Robust methods such as Browne's asymptotically distribution-free method and Satorra Bentler's mean scaling statistic were developed under the presumption of non-normality in the factors and errors. This paper finds new application to the case where factors and errors are normally distributed in the population but the skewness of the obtained test statistic is still high due to sampling error in the observed indicators. An extension of Satorra Bentler's statistic is proposed that not only scales the mean but also adjusts the degrees of freedom based on the skewness of the obtained test statistic in order to improve its robustness under small samples. A simple simulation study shows that this third moment adjusted statistic asymptotically performs on par with previously proposed methods, and at a very small sample size offers superior Type I error rates under a properly specified model. Data from Mardia, Kent and Bibby's study of students tested for their ability in five content areas that were either open or closed book were used to illustrate the real-world performance of this statistic.

  15. 40 CFR Appendix C to Subpart F of... - Method for Testing Recovery Devices for Use With Small Appliances

    Science.gov (United States)

    2010-07-01

    ... for Use With Small Appliances C Appendix C to Subpart F of Part 82 Protection of Environment... Recovery Devices for Use With Small Appliances Recovery Efficiency Test Procedure for Refrigerant Recovery Equipment Used on Small Appliances The following test procedure is utilized to evaluate the efficiency of...

  16. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell.

  17. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    International Nuclear Information System (INIS)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y.

    2016-01-01

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell

  18. Fabrication and testing of small scale mock-ups of ITER shielding blanket

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Toshihisa; Sato, Satoshi; Suzuki, Satoshi; Yokoyama, Kenji; Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Takatsu, Hideyuki; Ohara, Yoshihiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1998-12-01

    Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first wall mock-up, a two-step brazing was tried. All mock-ups and the partial model were successfully fabricated with a satisfactory dimensional accuracy. The small scale primary first wall mock-up was thermo-mechanically tested under high heat fluxes of 5-7 MW/m{sup 2} for 2500 cycles in total. Satisfactory heat removal performance and integrity of the mock-up against cyclic high heat flux loads were confirmed by measurement during the tests and destructive examination after the tests. Similar high heat flux tests were also performed with the small scale baffle first wall mock-up under 5-10 MW/m{sup 2} for 4500 cycles in total resulting in sufficient heat removal capability and integrity confirmed by measurements during the tests. (author)

  19. Fabrication and testing of small scale mock-ups of ITER shielding blanket

    International Nuclear Information System (INIS)

    Hatano, Toshihisa; Sato, Satoshi; Suzuki, Satoshi; Yokoyama, Kenji; Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Takatsu, Hideyuki; Ohara, Yoshihiro

    1998-12-01

    Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first wall mock-up, a two-step brazing was tried. All mock-ups and the partial model were successfully fabricated with a satisfactory dimensional accuracy. The small scale primary first wall mock-up was thermo-mechanically tested under high heat fluxes of 5-7 MW/m 2 for 2500 cycles in total. Satisfactory heat removal performance and integrity of the mock-up against cyclic high heat flux loads were confirmed by measurement during the tests and destructive examination after the tests. Similar high heat flux tests were also performed with the small scale baffle first wall mock-up under 5-10 MW/m 2 for 4500 cycles in total resulting in sufficient heat removal capability and integrity confirmed by measurements during the tests. (author)

  20. Testing of the multi-application small light water reactor (MASLWR) passive safety systems

    International Nuclear Information System (INIS)

    Reyes, Jose N.; Groome, John; Woods, Brian G.; Young, Eric; Abel, Kent; Yao, You; Yoo, Yeon Jong

    2007-01-01

    Experimental thermal hydraulic research has been conducted at Oregon State University for the purpose of assessing the performance of a new reactor design concept, the multi-application small light water reactor (MASLWR). The MASLWR is a pressurized light water reactor design with a net output of 35 MWe that uses natural circulation in both normal and transient operation. Due to its small size, portability and modularity, the MASLWR design is well suited to help fill the potential need for grid appropriate reactor designs for smaller electricity grids as may be found in developing or remote regions. The purpose of the OSU MASLWR test facility is to assess the operation of the MASLWR under normal full operating pressure and full temperature conditions and to assess the passive safety systems under transient conditions. The data generated by the testing program will be used to assess computer code calculations and to provide a better understanding of the thermal-hydraulic phenomena in the design of the MASLWR NSSS. During this testing program, four tests were conducted at the OSU MASLWR test facility. These tests included one design basis accident and one beyond design basis accident. During the performance of these tests, plant operations to include start up, normal operation and shut down evolutions were demonstrated successfully

  1. A simple in chemico method for testing skin sensitizing potential of chemicals using small endogenous molecules.

    Science.gov (United States)

    Nepal, Mahesh Raj; Shakya, Rajina; Kang, Mi Jeong; Jeong, Tae Cheon

    2018-06-01

    Among many of the validated methods for testing skin sensitization, direct peptide reactivity assay (DPRA) employs no cells or animals. Although no immune cells are involved in this assay, it reliably predicts the skin sensitization potential of a chemical in chemico. Herein, a new method was developed using endogenous small-molecular-weight compounds, cysteamine and glutathione, rather than synthetic peptides, to differentiate skin sensitizers from non-sensitizers with an accuracy as high as DPRA. The percent depletion of cysteamine and glutathione by test chemicals was measured by an HPLC equipped with a PDA detector. To detect small-size molecules, such as cysteamine and glutathione, a derivatization by 4-(4-dimethylaminophenylazo) benzenesulfonyl chloride (DABS-Cl) was employed prior to the HPLC analysis. Following test method optimization, a cut-off criterion of 7.14% depletion was applied to differentiate skin sensitizers from non-sensitizers in combination of the ratio of 1:25 for cysteamine:test chemical with 1:50 for glutathione:test chemical for the best predictivity among various single or combination conditions. Although overlapping HPLC peaks could not be fully resolved for some test chemicals, high levels of sensitivity (100.0%), specificity (81.8%), and accuracy (93.3%) were obtained for 30 chemicals tested, which were comparable or better than those achieved with DPRA. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Comparative study on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  3. Determination of the onset of ductile crack extension in 2 1/4 Cr 1 Mo steel by multi-specimen J integral testing

    International Nuclear Information System (INIS)

    Druce, S.G.

    1982-02-01

    Results obtained at AERE Harwell as part of the first phase of the European Group on Fracture round robin activity into ductile crack initiation detection are presented and discussed. Data are analysed using the current ASTM Jsub(IC) testing procedure and by an alternative procedure. Difficulties in the definition of 'initiation' are highlighted and deficiencies of the ASTM procedure exposed. The ASTM Jsub(IC) value for 2 1/4 Cr 1 Mo steel was determined as 0.21 MN/m. The alternative procedure provides a more accurate evaluation of the 'initiation' value of J, that is, at the point of crack advance in excess of that due to crack tip blunting. Using this procedure the 'initiation' value, Jsub(i), was measured as 0.14 MN/m. (author)

  4. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Science.gov (United States)

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  5. Testing for HPV as an objective measure for quality assurance in gynecologic cytology: positive rates in equivocal and abnormal specimens and comparison with the ASCUS to SIL ratio.

    Science.gov (United States)

    Ko, Vincent; Nanji, Shabin; Tambouret, Rosemary H; Wilbur, David C

    2007-04-25

    Inappropriate use of the category of atypical squamous cells of undetermined significance (ASCUS) can result in overtreatment or undertreatment of patients, which may decrease the cost effectiveness of screening. Quality assurance tools, such as the ASCUS to squamous intraepithelial lesion ratio (ASCUS:SIL) and case review, are imperfect. High-risk HPV (hrHPV) testing is an objective test for a known viral carcinogen, and hrHPV may be more useful in monitoring the quality of ASCUS interpretations. hrHPV rates for cytologic diagnoses and patient age groups were calculated for a 2-year period. All hrHPV results for ASCUS and SIL over a 17-month period were analyzed by patient age group, over time, and by individual cytopathologist to compare hrHPV rates with the corresponding ASCUS:SIL. The hrHPV positive rate for SIL was >90%, and it was 32.6% for ASCUS. Stratification by patient age showed that approximately 50% of patients younger than 30 years and older than 70 years of age were hrHPV positive, whereas other patients had a lower rate ranging from 14% to 34%. The overall ASCUS:SIL was 1.42, and the overall hrHPV positive rate was 39.9%. Over time and by individual cytopathologist, the hrHPV rate performed similarly to the ASCUS:SIL. The analysis by patient age showed a high statistical correlation (R(2) = 0.9772) between the 2 methods. Despite differences between these techniques, the hrHPV rate closely recapitulates the ASCUS:SIL. When used together, the 2 methods can complement each other. The desirable hrHPV-positive range appears to be 40% to 50%; however, this may vary based on the patient population. The hrHPV rate is as quick and cost effective as determining the ASCUS:SIL. (c) 2007 American Cancer Society.

  6. Environmental Testing Philosophy for a Sandia National Laboratories' Small Satellite Project - A Retrospective

    Energy Technology Data Exchange (ETDEWEB)

    CAP,JEROME S.

    2000-08-24

    Sandia has recently completed the flight certification test series for the Multi-Spectral Thermal Imaging satellite (MTI), which is a small satellite for which Sandia was the system integrator. A paper was presented at the 16th Aerospace Testing Seminar discussing plans for performing the structural dynamics certification program for that satellite. The testing philosophy was originally based on a combination of system level vibroacoustic tests and component level shock and vibration tests. However, the plans evolved to include computational analyses using both Finite Element Analysis and Statistical Energy Analysis techniques. This paper outlines the final certification process and discuss lessons learned including both things that went well and things that should/could have been done differently.

  7. Evaluation of proxy tests for SFSN: evidence for mixed small and large fiber dysfunction.

    Directory of Open Access Journals (Sweden)

    Hamid Ebadi

    Full Text Available BACKGROUND: Though intra-epidermal nerve fiber density (IENFD is considered the gold standard for diagnosis of small fiber sensory neuropathy (SFSN, we aimed to determine if novel threshold values derived from standard tests of small or large fiber function could serve as diagnostic alternatives. METHODS: Seventy-four consecutive patients with painful polyneuropathy and normal nerve conduction studies (NCS were defined as SFSN cases or controls by distal IENFD <5.4 and ≥5.4 fibers/mm, respectively. Diagnostic performance of small fiber [cooling (CDT and heat perception (HP thresholds, axon reflex-mediated neurogenic vasodilatation] and large fiber function tests [vibration perception thresholds (VPT and sural nerve conduction parameters] were determined by receiver operating-characteristic (ROC curve analyses. RESULTS: The 26(35% SFSN cases had mean IENFD 3.3±1.7 fibers/mm and the 48(65% controls 9.9±2.9 fibers/mm. Male gender (p = 0.02 and older age (p = 0.02 were associated with SFSN cases compared to controls. VPT were higher and CDT lower in SFSN cases, but the largest magnitude of differences was observed for sural nerve amplitude. It had the greatest area under the ROC curve (0.75 compared to all other tests (p<0.001 for all comparisons and the optimal threshold value of ≤12 µV defined SFSN cases with 80% sensitivity and 72% specificity. CONCLUSION: In patients presenting with polyneuropathy manifestations and normal NCS, though small fiber function tests were intuitively considered the best alternative measures to predict reduced IENFD, their diagnostic performance was poor. Instead, novel threshold values within the normal range for large fiber tests should be considered as an alternative strategy to select subjects for skin biopsy in diagnostic protocols for SFSN.

  8. Development of a model and test equipment for cold flow tests at 500 atm of small nuclear light bulb configurations

    Science.gov (United States)

    Jaminet, J. F.

    1972-01-01

    A model and test equipment were developed and cold-flow-tested at greater than 500 atm in preparation for future high-pressure rf plasma experiments and in-reactor tests with small nuclear light bulb configurations. With minor exceptions, the model chamber is similar in design and dimensions to a proposed in-reactor geometry for tests with fissioning uranium plasmas in the nuclear furnace. The model and the equipment were designed for use with the UARL 1.2-MW rf induction heater in tests with rf plasmas at pressures up to 500 atm. A series of cold-flow tests of the model was then conducted at pressures up to about 510 atm. At 504 atm, the flow rates of argon and cooling water were 3.35 liter/sec (STP) and 26 gal/min, respectively. It was demonstrated that the model is capable of being operated for extended periods at the 500-atm pressure level and is, therefore, ready for use in initial high-pressure rf plasma experiments.

  9. Genomic treasure troves: complete genome sequencing of herbarium and insect museum specimens.

    Science.gov (United States)

    Staats, Martijn; Erkens, Roy H J; van de Vossenberg, Bart; Wieringa, Jan J; Kraaijeveld, Ken; Stielow, Benjamin; Geml, József; Richardson, James E; Bakker, Freek T

    2013-01-01

    Unlocking the vast genomic diversity stored in natural history collections would create unprecedented opportunities for genome-scale evolutionary, phylogenetic, domestication and population genomic studies. Many researchers have been discouraged from using historical specimens in molecular studies because of both generally limited success of DNA extraction and the challenges associated with PCR-amplifying highly degraded DNA. In today's next-generation sequencing (NGS) world, opportunities and prospects for historical DNA have changed dramatically, as most NGS methods are actually designed for taking short fragmented DNA molecules as templates. Here we show that using a standard multiplex and paired-end Illumina sequencing approach, genome-scale sequence data can be generated reliably from dry-preserved plant, fungal and insect specimens collected up to 115 years ago, and with minimal destructive sampling. Using a reference-based assembly approach, we were able to produce the entire nuclear genome of a 43-year-old Arabidopsis thaliana (Brassicaceae) herbarium specimen with high and uniform sequence coverage. Nuclear genome sequences of three fungal specimens of 22-82 years of age (Agaricus bisporus, Laccaria bicolor, Pleurotus ostreatus) were generated with 81.4-97.9% exome coverage. Complete organellar genome sequences were assembled for all specimens. Using de novo assembly we retrieved between 16.2-71.0% of coding sequence regions, and hence remain somewhat cautious about prospects for de novo genome assembly from historical specimens. Non-target sequence contaminations were observed in 2 of our insect museum specimens. We anticipate that future museum genomics projects will perhaps not generate entire genome sequences in all cases (our specimens contained relatively small and low-complexity genomes), but at least generating vital comparative genomic data for testing (phylo)genetic, demographic and genetic hypotheses, that become increasingly more horizontal

  10. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  11. Influence of friction on stress and strain distributions in small punch creep test models

    Czech Academy of Sciences Publication Activity Database

    Dymáček, Petr; Seitl, Stanislav; Milička, Karel; Dobeš, Ferdinand

    417-418, - (2010), s. 561-564 ISSN 1013-9826. [International Conference on Fracture and Damage Mechanics /8./. Malta, 08.09.2009-10.09.2009] R&D Projects: GA AV ČR(CZ) IAA200410801; GA AV ČR(CZ) 1QS200410502 Institutional research plan: CEZ:AV0Z20410507 Keywords : small punch test * creep * chromium steel * finite element method Subject RIV: JG - Metallurgy www.scientific.net/KEM.417-418.561

  12. Small Sample Properties of the Wilcoxon Signed Rank Test with Discontinuous and Dependent Observations

    OpenAIRE

    Nadine Chlass; Jens J. Krueger

    2007-01-01

    This Monte-Carlo study investigates sensitivity of the Wilcoxon signed rank test to certain assumption violations in small samples. Emphasis is put on within-sample-dependence, between-sample dependence, and the presence of ties. Our results show that both assumption violations induce severe size distortions and entail power losses. Surprisingly, these consequences do vary substantially with other properties the data may display. Results provided are particularly relevant for experimental set...

  13. Estimation of ductility of Fe-Al alloys by means of small punch test

    Czech Academy of Sciences Publication Activity Database

    Dobeš, Ferdinand; Milička, Karel

    Roč.18, č.7 (2010), s. 1357-1359 ISSN 0966-9795. [Discussion Meeting on the Development of Innovative Iron Aluminium Alloys /5./. Praha, 21.09.2009-24.09.2009] R&D Projects: GA ČR GA106/08/1238 Institutional research plan: CEZ:AV0Z20410507 Keywords : iron aluminides * brittleness * small punch test Subject RIV: JG - Metallurgy Impact factor: 2.327, year: 2010

  14. Study of the upper die clamping conditions in the small punch test

    Czech Academy of Sciences Publication Activity Database

    Andrés, D.; Dymáček, Petr

    86A, DEC (2016), s. 117-123 ISSN 0167-8442 R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068 Institutional support: RVO:68081723 Keywords : Small punch test * Finite element method * Parametric study * High temperature * Creep Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.659, year: 2016 http://www.sciencedirect.com/science/article/pii/S0167844216301835

  15. Cable testing for Fermilab's high field magnets using small racetrack coils

    International Nuclear Information System (INIS)

    Feher, S.; Ambrosio, G.; Andreev, N.; Barzi, E.; Bordini, B.; Bossert, R.; Carcagno, R.; Kashikhin, V.I.; Kashikhin, V.V.; Lamm, M.J.; Novitski, I.; Orris, D.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.; Yamada, R.; Zlobin, A.V.

    2004-01-01

    As part of the High Field Magnet program at Fermilab simple magnets have been designed utilizing small racetrack coils based on a sound mechanical structure and bladder technique developed by LBNL. Two of these magnets have been built in order to test Nb 3 Sn cables used in cos-theta dipole models. The powder-in-tube strand based cable exhibited excellent performance. It reached its critical current limit within 14 quenches. Modified jelly roll strand based cable performance was limited by magnetic instabilities at low fields as previously tested dipole models which used similar cable

  16. Numerical comparison of improved methods of testing in contingency tables with small frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Sugiura, Nariaki; Otake, Masanori

    1968-11-14

    The significance levels of various tests for a general c x k contingency table are usually given by large sample theory. But they are not accurate for the one having small frequencies. In this paper, a numerical evaluation was made to determine how good the approximation of significance level is for various improved tests that have been developed by Nass, Yoshimura, Gart, etc. for c x k contingency table with small frequencies in some of cells. For this purpose we compared the significance levels of the various approximate methods (i) with those of one-sided tail defined in terms of exact probabilities for given marginals in 2 x 2 table; (ii) with those of exact probabilities accumulated in the order of magnitude of Chi/sup 2/ statistic or likelihood ratio (=LR) statistic in 2 x 3 table mentioned by Yates. In 2 x 2 table it is well known that Yates' correction gives satisfactory result for small cell frequencies and the other methods that we have not referred here, can be considered if we devote our attention only to 2 x 2 or 2 x k table. But we are mainly interested in comparing the methods that are applicable to a general c x k table. It appears that such a comparison for the various improved methods in the same example has not been made explicitly, even though these tests are frequently used in biological and medical research. 9 references, 6 figures, 6 tables.

  17. Shrinkage-based diagonal Hotelling’s tests for high-dimensional small sample size data

    KAUST Repository

    Dong, Kai

    2015-09-16

    DNA sequencing techniques bring novel tools and also statistical challenges to genetic research. In addition to detecting differentially expressed genes, testing the significance of gene sets or pathway analysis has been recognized as an equally important problem. Owing to the “large pp small nn” paradigm, the traditional Hotelling’s T2T2 test suffers from the singularity problem and therefore is not valid in this setting. In this paper, we propose a shrinkage-based diagonal Hotelling’s test for both one-sample and two-sample cases. We also suggest several different ways to derive the approximate null distribution under different scenarios of pp and nn for our proposed shrinkage-based test. Simulation studies show that the proposed method performs comparably to existing competitors when nn is moderate or large, but it is better when nn is small. In addition, we analyze four gene expression data sets and they demonstrate the advantage of our proposed shrinkage-based diagonal Hotelling’s test.

  18. Shrinkage-based diagonal Hotelling’s tests for high-dimensional small sample size data

    KAUST Repository

    Dong, Kai; Pang, Herbert; Tong, Tiejun; Genton, Marc G.

    2015-01-01

    DNA sequencing techniques bring novel tools and also statistical challenges to genetic research. In addition to detecting differentially expressed genes, testing the significance of gene sets or pathway analysis has been recognized as an equally important problem. Owing to the “large pp small nn” paradigm, the traditional Hotelling’s T2T2 test suffers from the singularity problem and therefore is not valid in this setting. In this paper, we propose a shrinkage-based diagonal Hotelling’s test for both one-sample and two-sample cases. We also suggest several different ways to derive the approximate null distribution under different scenarios of pp and nn for our proposed shrinkage-based test. Simulation studies show that the proposed method performs comparably to existing competitors when nn is moderate or large, but it is better when nn is small. In addition, we analyze four gene expression data sets and they demonstrate the advantage of our proposed shrinkage-based diagonal Hotelling’s test.

  19. Manufacturing, testing and post-test examination of ITER divertor vertical target W small scale mock-ups

    International Nuclear Information System (INIS)

    Visca, Eliseo; Cacciotti, Emanuele; Komarov, Anton; Libera, Stefano; Litunovsky, Nikolay; Makhankov, Alexey; Mancini, Andrea; Merola, Mario; Pizzuto, Aldo; Riccardi, Bruno; Roccella, Selanna

    2011-01-01

    ENEA is involved in the International Thermonuclear Experimental Reactor (ITER) R and D activities. During the last years ENEA has set up and widely tested a manufacturing process, named Hot Radial Pressing (HRP), suitable for the construction of high heat flux plasma-facing components, such as the divertor targets. In the frame of the EFDA contract six mock-ups were manufactured by HRP in the ENEA labs using W monoblocks supplied by the Efremov Institute in St. Petersburg, Russian Federation and IG CuCrZr tubes. According to the technical specifications the mock-ups were examined by ultrasonic technique and after their acceptance they were delivered to the Efremov Institute TSEFEY-M e-beam facility for the thermal fatigue testing. The test consisted in 3000 cycles of 15 s heating and 15 s cooling at 10 MW/m 2 and finally 1000 cycles at 20 MW/m 2 . After the testing the ultrasonic non-destructive examination was repeated and the results compared with the investigation performed before the testing. A microstructure modification of the W monoblock material due to the overheating of the surfaces and the copper interlayer structure modification were observed in the high heat flux area. The leakage points of the mock-ups that did not conclude the testing were localized in the middle of the monoblock while they were expected between two monoblocks. This paper reports the manufacturing route, the thermal fatigue testing, the pre and post non destructive examination and finally the results of the destructive examination performed on the monoblock small scale mock-ups.

  20. Elemental analysis of soils using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS) with multivariate discrimination: tape mounting as an alternative to pellets for small forensic transfer specimens.

    Science.gov (United States)

    Jantzi, Sarah C; Almirall, José R

    2014-01-01

    Elemental analysis of soil is a useful application of both laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS) in geological, agricultural, environmental, archeological, planetary, and forensic sciences. In forensic science, the question to be answered is often whether soil specimens found on objects (e.g., shoes, tires, or tools) originated from the crime scene or other location of interest. Elemental analysis of the soil from the object and the locations of interest results in a characteristic elemental profile of each specimen, consisting of the amount of each element present. Because multiple elements are measured, multivariate statistics can be used to compare the elemental profiles in order to determine whether the specimen from the object is similar to one of the locations of interest. Previous work involved milling and pressing 0.5 g of soil into pellets before analysis using LA-ICP-MS and LIBS. However, forensic examiners prefer techniques that require smaller samples, are less time consuming, and are less destructive, allowing for future analysis by other techniques. An alternative sample introduction method was developed to meet these needs while still providing quantitative results suitable for multivariate comparisons. The tape-mounting method involved deposition of a thin layer of soil onto double-sided adhesive tape. A comparison of tape-mounting and pellet method performance is reported for both LA-ICP-MS and LIBS. Calibration standards and reference materials, prepared using the tape method, were analyzed by LA-ICP-MS and LIBS. As with the pellet method, linear calibration curves were achieved with the tape method, as well as good precision and low bias. Soil specimens from Miami-Dade County were prepared by both the pellet and tape methods and analyzed by LA-ICP-MS and LIBS. Principal components analysis and linear discriminant analysis were applied to the multivariate data

  1. Small-Scale Testing of Laterally Loaded Non-Slender Monopiles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Roesen, Hanne Ravn; Ibsen, Lars Bo

    in sand subjected to lateral loading are analysed by means of small-scale laboratory tests. The six quasi-static tests are conducted on piles with diameters of 40 mm and 100 mm and a slenderness ratio, L/D, of 5. In order to minimise scale effects, the tests are carried out in a pressure tank at stress...... levels of 0 kPa, 50 kPa, and 100 kPa, respectively. From the tests load-deflection relationships of the piles at three levels above the soil surface are obtained. The load-deflection relationships reveal that the uncertainties of the results for the pile with diameter of 40~mm are large due to the small......In current design of offshore wind turbines, monopiles are often used as foundation. The behaviour of the monopiles when subjected to lateral loading has not been fully investigated, e.g. the diameter effect on the soil response. In this paper the behaviour of two non-slender aluminium piles...

  2. Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.

    Science.gov (United States)

    Tang, Yi-Wei; Sefers, Susan E; Li, Haijing; Kohn, Debra J; Procop, Gary W

    2005-09-01

    A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.

  3. Wireless capsule endoscopy of the small bowel: development, testing, and first human trials

    Science.gov (United States)

    Swain, Paul; Iddan, Gavriel J.; Meron, Gavriel; Glukhovsky, Arkady

    2001-01-01

    Small bowel endoscopy with existing endoscopes is limited by problems of discomfort and the technical difficulty of advancing far into the small-bowel. Our aim has been to develop and test wireless capsule endoscopy. Wireless endoscopes, in the form of capsules (11 x 33 mm), were constructed by Given Imaging. These were powered by silver oxide batteries and each contained a CMOS imaging chip and miniature processor, white light emitting diodes (LEDs), a short focal length lens, and a miniature transmitter and antenna. Two video frames per second were transmitted, using radio-frequency (approx. 410 MHz), to an array of aerials attached to the body. The array of aerials can also be used to calculate the position of the capsule in the body. The images were stored on a portable recorder carried on a belt and subsequently downloaded for analysis. The batteries allow more than 5 hours of recording, although the capsule generally passes through the whole small bowel in under two hours. Clear video images of the human bowel were recorded from the pylorus to the caecum. Wireless endoscopy, for the first time, allows painless optical imaging of the whole of the small bowel.

  4. Numerical Test of Analytical Theories for Perpendicular Diffusion in Small Kubo Number Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Heusen, M.; Shalchi, A., E-mail: husseinm@myumanitoba.ca, E-mail: andreasm4@yahoo.com [Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2 (Canada)

    2017-04-20

    In the literature, one can find various analytical theories for perpendicular diffusion of energetic particles interacting with magnetic turbulence. Besides quasi-linear theory, there are different versions of the nonlinear guiding center (NLGC) theory and the unified nonlinear transport (UNLT) theory. For turbulence with high Kubo numbers, such as two-dimensional turbulence or noisy reduced magnetohydrodynamic turbulence, the aforementioned nonlinear theories provide similar results. For slab and small Kubo number turbulence, however, this is not the case. In the current paper, we compare different linear and nonlinear theories with each other and test-particle simulations for a noisy slab model corresponding to small Kubo number turbulence. We show that UNLT theory agrees very well with all performed test-particle simulations. In the limit of long parallel mean free paths, the perpendicular mean free path approaches asymptotically the quasi-linear limit as predicted by the UNLT theory. For short parallel mean free paths we find a Rechester and Rosenbluth type of scaling as predicted by UNLT theory as well. The original NLGC theory disagrees with all performed simulations regardless what the parallel mean free path is. The random ballistic interpretation of the NLGC theory agrees much better with the simulations, but compared to UNLT theory the agreement is inferior. We conclude that for this type of small Kubo number turbulence, only the latter theory allows for an accurate description of perpendicular diffusion.

  5. Numerical Test of Analytical Theories for Perpendicular Diffusion in Small Kubo Number Turbulence

    International Nuclear Information System (INIS)

    Heusen, M.; Shalchi, A.

    2017-01-01

    In the literature, one can find various analytical theories for perpendicular diffusion of energetic particles interacting with magnetic turbulence. Besides quasi-linear theory, there are different versions of the nonlinear guiding center (NLGC) theory and the unified nonlinear transport (UNLT) theory. For turbulence with high Kubo numbers, such as two-dimensional turbulence or noisy reduced magnetohydrodynamic turbulence, the aforementioned nonlinear theories provide similar results. For slab and small Kubo number turbulence, however, this is not the case. In the current paper, we compare different linear and nonlinear theories with each other and test-particle simulations for a noisy slab model corresponding to small Kubo number turbulence. We show that UNLT theory agrees very well with all performed test-particle simulations. In the limit of long parallel mean free paths, the perpendicular mean free path approaches asymptotically the quasi-linear limit as predicted by the UNLT theory. For short parallel mean free paths we find a Rechester and Rosenbluth type of scaling as predicted by UNLT theory as well. The original NLGC theory disagrees with all performed simulations regardless what the parallel mean free path is. The random ballistic interpretation of the NLGC theory agrees much better with the simulations, but compared to UNLT theory the agreement is inferior. We conclude that for this type of small Kubo number turbulence, only the latter theory allows for an accurate description of perpendicular diffusion.

  6. Establishing a Ballistic Test Methodology for Documenting the Containment Capability of Small Gas Turbine Engine Compressors

    Science.gov (United States)

    Heady, Joel; Pereira, J. Michael; Ruggeri, Charles R.; Bobula, George A.

    2009-01-01

    A test methodology currently employed for large engines was extended to quantify the ballistic containment capability of a small turboshaft engine compressor case. The approach involved impacting the inside of a compressor case with a compressor blade. A gas gun propelled the blade into the case at energy levels representative of failed compressor blades. The test target was a full compressor case. The aft flange was rigidly attached to a test stand and the forward flange was attached to a main frame to provide accurate boundary conditions. A window machined in the case allowed the projectile to pass through and impact the case wall from the inside with the orientation, direction and speed that would occur in a blade-out event. High-peed, digital-video cameras provided accurate velocity and orientation data. Calibrated cameras and digital image correlation software generated full field displacement and strain information at the back side of the impact point.

  7. TLTA/6431, Two-Loop-Test-Apparatus, BWR/6 Simulator, Small-Break LOCA

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: The Two-Loop-Test-Apparatus (TLTA) is a 1:624 volume scaled BWR/6 simulator. It was the predecessor of the better-scaled FIST facility. The facility is capable of full BWR system pressure and has a simulated core with a full size 8 x 8, full power single bundle of indirect electrically heated rods. All major BWR systems are simulated including lower plenum, guide tube, core region (bundle and bypass), upper plenum, steam separator, steam dome, annular downcomer, recirculation loops and ECC injection systems. The fundamental scaling consideration was to achieve real-time response. A number of the scaling compromises present in TLTA were corrected in the FIST configuration. These compromises include a number of regional volumes and component elevations. 2 - Description of test: 64.45 sqcm small break LOCA with activation of the full emergency core cooling system, but without activation of the automatic decompression system

  8. Applicability of the Modified Ritchie-Knott-Rice Failure Criterion to Examine the Feasibility of Miniaturized Charpy Type SE(B Specimens

    Directory of Open Access Journals (Sweden)

    Toshiyuki Meshii

    2016-01-01

    Full Text Available This paper examined whether the modified Ritchie-Knott-Rice (RKR failure criterion can be applied to examine the feasibility of miniaturized Charpy type SE(B specimens of thickness-to-width ratio B/W=1. The modified RKR failure criterion considered in this paper is the (4δt,σ22c criterion which predicts the onset of cleavage fracture when the midplane crack-opening stress measured at a distance equal to four times the crack-tip opening displacement, denoted as σ22d, exceeds a critical stress σ22c. Specimens with B values of 25, 10, 3, and 2 mm (denoted as 25t, 10t, 3t, and 2t specimens, resp. manufactured with 0.55% carbon steel were tested at 20°C. The results showed that the modified RKR criterion could appropriately predict the occurrence of cleavage fracture accompanied by negligibly small stable crack extension (denoted as KJc fracture naturally for the 25t and 10t specimens. The modified RKR criterion could also predict that KJc fracture does not occur for the 2t specimen. The σ22c obtained from specimens for the 25t and 10t specimens exhibited only a small difference, indicating that the Jc obtained from the 10t specimens can be used to predict the Jc that will be obtained with the 25t specimens.

  9. Development of Next Generation Memory Test Experiment for Deployment on a Small Satellite

    Science.gov (United States)

    MacLeod, Todd; Ho, Fat D.

    2012-01-01

    The original Memory Test Experiment successfully flew on the FASTSAT satellite launched in November 2010. It contained a single Ramtron 512K ferroelectric memory. The memory device went through many thousands of read/write cycles and recorded any errors that were encountered. The original mission length was schedule to last 6 months but was extended to 18 months. New opportunities exist to launch a similar satellite and considerations for a new memory test experiment should be examined. The original experiment had to be designed and integrated in less than two months, so the experiment was a simple design using readily available parts. The follow-on experiment needs to be more sophisticated and encompass more technologies. This paper lays out the considerations for the design and development of this follow-on flight memory experiment. It also details the results from the original Memory Test Experiment that flew on board FASTSAT. Some of the design considerations for the new experiment include the number and type of memory devices to be used, the kinds of tests that will be performed, other data needed to analyze the results, and best use of limited resources on a small satellite. The memory technologies that are considered are FRAM, FLASH, SONOS, Resistive Memory, Phase Change Memory, Nano-wire Memory, Magneto-resistive Memory, Standard DRAM, and Standard SRAM. The kinds of tests that could be performed are read/write operations, non-volatile memory retention, write cycle endurance, power measurements, and testing Error Detection and Correction schemes. Other data that may help analyze the results are GPS location of recorded errors, time stamp of all data recorded, radiation measurements, temperature, and other activities being perform by the satellite. The resources of power, volume, mass, temperature, processing power, and telemetry bandwidth are extremely limited on a small satellite. Design considerations must be made to allow the experiment to not interfere

  10. Thermal-hydraulic analysis of PWR small assembly for irradiation test of CARR

    International Nuclear Information System (INIS)

    Yin Hao; Zou Yao; Liu Xingmin

    2015-01-01

    The thermal-hydraulic behaviors of the PWR 4 × 4 small assembly tested in the high temperature and high pressure loop of China Advanced Research Reactor were analyzed. The CFD method was used to carry out 3D simulation of the model, thus detailed thermal-hydraulic parameters were obtained. Firstly, the simplified model was simulated to give the 3D temperature and velocity distributions and analyze the heat transfer process. Then the whole scale small assembly model was simulated and the simulation results were compared with those of simplified rod bundle model. Its flow behavior was studied and flow mixing characteristics of the grids were analyzed, and the mixing factor of the grid was calculated and can be used for further thermal-hydraulic study. It is shown that the highest temperature of the fuel rod meets the design limit and the mixing effect of the grid is obvious. (authors)

  11. Irradiation tests of a small-sized motor with radiation resistance

    International Nuclear Information System (INIS)

    Nakamichi, M.; Ishitsuka, E.; Shimakawa, S.; Kan, S.

    2007-01-01

    In the Test Blanket Module (TBM) of the International Thermonuclear Experimental Reactor (ITER), tritium production and release behavior will be studied using neutrons from fusion reactions, as the blanket development for a demonstration (DEMO) reactor. For development of the TBM, in-pile functional tests are planned, including an integrated irradiation experiment of a fusion blanket mock-up for pulsed operation simulating the ITER operation mode, using the Japan Materials Testing Reactor (JMTR) of Japan Atomic Energy Agency (JAEA).Due to be installed in an irradiation rig, a small-sized motor has to be developed for rotating a neutron absorber with a window to realize the simulated pulse operation. Since degradation of materials of the motor may be caused by radiation damage due to neutron and gamma-ray irradiation, it is important to examine the soundness of the motor materials under the neutron and gamma irradiation.In the present study, a small-sized motor with increased radiation resistance was developed as follows. A design of a commercial alternate current (AC) servomotor was adopted in the base structure, and some components of the motor were replaced by those made of radiation-proof materials, through elimination of organic materials. Polyester-coated wire for field coil and epoxy for fixed resin were replaced by polyimide-coated wire and polysiloxane filled with MgO and Al 2 O 3 , respectively. Furthermore, inorganic lubricant (Mo-based coating of 4 micro meter in thickness) was treated on the surface of a gear, instead of organic (polyphenylether) oil.Radiation-induced degradation of the components of the developed small-sized motor was examined using JMTR and the Japan Research Reactor No.4 (JRR-4) of JAEA. The motor was operating normally up to a gamma-ray dose of 7 x 10 8 Gy, a fast neutron (E>1 MeV) fluence of 2 x 10 21 m -2 and a thermal neutron (E 22 m -2 . The irradiated gamma-ray dose for this motor is about 700 times as high as the operation

  12. Testing solar panels for small-size satellites: the UPMSAT-2 mission

    International Nuclear Information System (INIS)

    Roibás-Millán, E; Alonso-Moragón, A; Jiménez-Mateos, A G; Pindado, S

    2017-01-01

    At present, the development of small-size satellites by universities, companies and research institutions has become usual practice, and is spreading rapidly. In this kind of project cost plays a significant role. One of the main areas are the assembly, integration and test (AIT) plans, which carry an associated cost for simulating environmental conditions. For instance, in the power subsystems test and, in particular, in the testing of solar panels, the irradiance and temperature conditions might be optimum so the performance of the system can be shown next to real operational conditions. To reproduce the environmental conditions in terms of irradiance, solar simulators are usually used, which carries an associated increase in cost for testing the equipment. The aim of this paper is to present an alternative and inexpensive way to perform AIT plans on spacecraft power subsystems, from a testing campaign performed using outdoor clean-sky conditions and an isolation system to protect the panels. A post-process of the measured data is therefore needed, taking into account the conditions in which the test has been accomplished. The I–V characteristics obtained are compared with a theoretical 1-diode/2-resistor equivalent electric circuit, achieving enough precision based solely on the manufacturer’s data. (paper)

  13. Automated High-Speed Video Detection of Small-Scale Explosives Testing

    Science.gov (United States)

    Ford, Robert; Guymon, Clint

    2013-06-01

    Small-scale explosives sensitivity test data is used to evaluate hazards of processing, handling, transportation, and storage of energetic materials. Accurate test data is critical to implementation of engineering and administrative controls for personnel safety and asset protection. Operator mischaracterization of reactions during testing contributes to either excessive or inadequate safety protocols. Use of equipment and associated algorithms to aid the operator in reaction determination can significantly reduce operator error. Safety Management Services, Inc. has developed an algorithm to evaluate high-speed video images of sparks from an ESD (Electrostatic Discharge) machine to automatically determine whether or not a reaction has taken place. The algorithm with the high-speed camera is termed GoDetect (patent pending). An operator assisted version for friction and impact testing has also been developed where software is used to quickly process and store video of sensitivity testing. We have used this method for sensitivity testing with multiple pieces of equipment. We present the fundamentals of GoDetect and compare it to other methods used for reaction detection.

  14. Testing solar panels for small-size satellites: the UPMSAT-2 mission

    Science.gov (United States)

    Roibás-Millán, E.; Alonso-Moragón, A.; Jiménez-Mateos, A. G.; Pindado, S.

    2017-11-01

    At present, the development of small-size satellites by universities, companies and research institutions has become usual practice, and is spreading rapidly. In this kind of project cost plays a significant role. One of the main areas are the assembly, integration and test (AIT) plans, which carry an associated cost for simulating environmental conditions. For instance, in the power subsystems test and, in particular, in the testing of solar panels, the irradiance and temperature conditions might be optimum so the performance of the system can be shown next to real operational conditions. To reproduce the environmental conditions in terms of irradiance, solar simulators are usually used, which carries an associated increase in cost for testing the equipment. The aim of this paper is to present an alternative and inexpensive way to perform AIT plans on spacecraft power subsystems, from a testing campaign performed using outdoor clean-sky conditions and an isolation system to protect the panels. A post-process of the measured data is therefore needed, taking into account the conditions in which the test has been accomplished. The I-V characteristics obtained are compared with a theoretical 1-diode/2-resistor equivalent electric circuit, achieving enough precision based solely on the manufacturer’s data.

  15. Overestimation of test performance by ROC analysis: Effect of small sample size

    International Nuclear Information System (INIS)

    Seeley, G.W.; Borgstrom, M.C.; Patton, D.D.; Myers, K.J.; Barrett, H.H.

    1984-01-01

    New imaging systems are often observer-rated by ROC techniques. For practical reasons the number of different images, or sample size (SS), is kept small. Any systematic bias due to small SS would bias system evaluation. The authors set about to determine whether the area under the ROC curve (AUC) would be systematically biased by small SS. Monte Carlo techniques were used to simulate observer performance in distinguishing signal (SN) from noise (N) on a 6-point scale; P(SN) = P(N) = .5. Four sample sizes (15, 25, 50 and 100 each of SN and N), three ROC slopes (0.8, 1.0 and 1.25), and three intercepts (0.8, 1.0 and 1.25) were considered. In each of the 36 combinations of SS, slope and intercept, 2000 runs were simulated. Results showed a systematic bias: the observed AUC exceeded the expected AUC in every one of the 36 combinations for all sample sizes, with the smallest sample sizes having the largest bias. This suggests that evaluations of imaging systems using ROC curves based on small sample size systematically overestimate system performance. The effect is consistent but subtle (maximum 10% of AUC standard deviation), and is probably masked by the s.d. in most practical settings. Although there is a statistically significant effect (F = 33.34, P<0.0001) due to sample size, none was found for either the ROC curve slope or intercept. Overestimation of test performance by small SS seems to be an inherent characteristic of the ROC technique that has not previously been described

  16. Investigation of Be/Cu joints via HHF tests of small-scale mockups

    Energy Technology Data Exchange (ETDEWEB)

    Giniatulin, R.; Gervash, A.; Komarov, V.L.; Litunovsky, N.; Mazul, I.; Yablokov, N. [Efremov Inst., St. Petersburg (Russian Federation)

    1998-01-01

    Beryllium-copper (Be/Cu) joints in divertor components work under cyclic heat loads. To develop reliable joints small-scale mockups are fabricated by divertor technologies and tested under the divertor conditions. One of the critical damaging factors that exist in the divertor and have to be simulated is thermocyclic heat loads in the range of 1-15 MW/m{sup 2}. This work presents the divertor mockups that have beryllium tiles with different dimensions (5 x 5 - 44 x 44) mm{sup 2} brazed with copper alloy heat sink. The electron beam was used to braze these mockups so as to decrease the formation of brittle intermetallic layers. The description of mockups design, geometry of armour tiles and fabrication techniques are presented in the paper. The results of screening and thermocyclic tests of these mockups in the heat flux range of 2-12 MW/m{sup 2} with a number of cycles {approx}10{sup 3} are presented. The results of metallographic analysis are also presented. The results of fabrication and testing with small-scale mockups for first wall application are also described. (author)

  17. Pi-Sat: A Low Cost Small Satellite and Distributed Spacecraft Mission System Test Platform

    Science.gov (United States)

    Cudmore, Alan

    2015-01-01

    Current technology and budget trends indicate a shift in satellite architectures from large, expensive single satellite missions, to small, low cost distributed spacecraft missions. At the center of this shift is the SmallSatCubesat architecture. The primary goal of the Pi-Sat project is to create a low cost, and easy to use Distributed Spacecraft Mission (DSM) test bed to facilitate the research and development of next-generation DSM technologies and concepts. This test bed also serves as a realistic software development platform for Small Satellite and Cubesat architectures. The Pi-Sat is based on the popular $35 Raspberry Pi single board computer featuring a 700Mhz ARM processor, 512MB of RAM, a flash memory card, and a wealth of IO options. The Raspberry Pi runs the Linux operating system and can easily run Code 582s Core Flight System flight software architecture. The low cost and high availability of the Raspberry Pi make it an ideal platform for a Distributed Spacecraft Mission and Cubesat software development. The Pi-Sat models currently include a Pi-Sat 1U Cube, a Pi-Sat Wireless Node, and a Pi-Sat Cubesat processor card.The Pi-Sat project takes advantage of many popular trends in the Maker community including low cost electronics, 3d printing, and rapid prototyping in order to provide a realistic platform for flight software testing, training, and technology development. The Pi-Sat has also provided fantastic hands on training opportunities for NASA summer interns and Pathways students.

  18. Enzymatic detection of formalin-fixed museum specimens for DNA analysis and enzymatic maceration of formalin-fixed specimens

    DEFF Research Database (Denmark)

    Sørensen, Margrethe; Redsted Rasmussen, Arne; Simonsen, Kim Pilkjær

    2016-01-01

    % ethanol. The method was subsequently tested on wild-living preserved specimens and an archived specimen. The protease enzyme used was SavinaseH 16 L, Type EX from Novozymes A/S. The enzymatic screening test demands only simple laboratory equipment. The method is useful for natural history collections...

  19. Prediction of fracture toughness based on experiments with sub-size specimens in the brittle and ductile regimes

    Energy Technology Data Exchange (ETDEWEB)

    Mahler, Michael, E-mail: Michael.Mahler@kit.edu; Aktaa, Jarir

    2016-04-15

    For determination of fracture toughness in the brittle regime or ductile fracture in the upper shelf region, special standard specifications are in use e.g. ASTM E399 or ASTM E1820. Due to the rigorous size requirements for specimen testing, it is necessary to use big specimens. To circumvent this problem an approach based on finite element (FE) simulations using the cohesive zone model (CZM) is used. The parameters of the cohesive zone model have been determined using sub-size specimens. With the identified parameters, simulations of standard-size specimens have been performed to successfully predict fracture toughness of standard-size specimens in the brittle and ductile regimes. The objective is to establish small size testing technology for the determination of fracture toughness. - Highlights: • Prediction of fracture toughness on standard-size specimens. • Valid fracture toughness based on sub-size specimens. • Triaxiality dependent cohesive zone model. • Approach works independent on fracture appearance (brittle, ductile).

  20. Electrical design for origami solar panels and a small spacecraft test mission

    Science.gov (United States)

    Drewelow, James; Straub, Jeremy

    2017-05-01

    Efficient power generation is crucial to the design of spacecraft. Mass, volume, and other limitations prevent the use of traditional spacecraft support structures from being suitable for the size of solar array required for some missions. Folding solar panel / panel array systems, however, present a number of design challenges. This paper considers the electrical design of an origami system. Specifically, it considers how to provide low impedance, durable channels for the generated power and the electrical aspects of the deployment system and procedure. The ability to dynamically reconfigure the electrical configuration of the solar cells is also discussed. Finally, a small satellite test mission to demonstrate the technology is proposed, before concluding.