WorldWideScience

Sample records for small arms

  1. Environmental Assessment of Lead at Camp Edwards, Massachusetts, Small Arms Ranges

    National Research Council Canada - National Science Library

    Clausen, Jay L; Korte, Nic; Bostick, Benjamin; Rice, Benjamin; Walsh, Matthew; Nelson, Andrew

    2007-01-01

    Environmental issues for small arms training with lead projectiles are examined in this report for Camp Edwards, Massachusetts, in order to evaluate whether past or future use of lead in small arms...

  2. Small arms proliferation. Report on working group 2

    International Nuclear Information System (INIS)

    1998-01-01

    The working group reported on the proliferation of small arms, light weapons non-lethal weapons, which have traditionally been given little attention in international talks on peace on the contrary to nuclear weapons which have been tested during the Second World War but never used in war later

  3. The Social Networks of Small Arms Proliferation: Mapping an Aviation Enabled Supply Chain

    National Research Council Canada - National Science Library

    Curwen, Philip A

    2007-01-01

    A complex network of dealers, brokers, financiers, and traffickers continue to funnel large quantities of small arms and ammunition into African conflict zones despite the presence of United Nations arms embargoes...

  4. International Small Arms and Light Weapons Transfers: U.S. Policy

    National Research Council Canada - National Science Library

    Grimmett, Richard F

    2006-01-01

    In recent years attention has been focused by international organizations and nongovernmental organizations in various fora on the issue of international small arms and light weapons transfers (SA/LW...

  5. Efforts of Proliferation of Small Arms in Sub-Sahara Africa

    National Research Council Canada - National Science Library

    Nganga, Frankonero

    2008-01-01

    .... Belligerents in the conflict areas for example Somali Sudan and parts of northern Uganda use the small arms and light weapons as the primary tools of violence causing deaths and injuring thousands...

  6. The UN panel of governmental experts on small arms: a Canadian perspective on their report

    International Nuclear Information System (INIS)

    DeClerq, D.G.

    1998-01-01

    After the end of the Cold War, the United Nations, some individual governments, non-govermental research organizations and academia began to focus increased attention on light weapons as an arms control proliferation issue particularly within the context of intrastate warfare and destabilizing criminal activities. In 1995 the Secretary-General to the Security Council in a report entitled, An Agenda for Peace stressed the need for 'practical disarmament in the context of the conflicts that the UN is actually dealing with and of the weapons most of them light weapons, that are actually killing people in the hundreds of thousands. Light weapons and small arms have been the subject of some 12 UN resolutions and documents among them, UN Resolution 49175M which addressed illicit arms trafficking and Annex I of UN Document A151142 which provided 'Guidelines for International Arms Transfers.' Within a different context, the UN Commission on Crime Prevention and Criminal Justice in Vienna recently made recommendations on the impact of small arms, primarily within the framework of criminal activities, accidents and suicides, illicit firearms trafficking, and domestic, regional and interregional firearms regulations. On 12 December 1995, Japan introduced Resolution 50/01/70 B which was the first attempt by the UN to clearly address small arms and light weapons as an arms control issue. (author)

  7. 2011 International Infantry and Joint Services Small Arms Systems Symposium, Exhibition and Firing Demonstration

    Science.gov (United States)

    2011-05-26

    Kinetics Tungsten Carbide Material Research and Development of Small Arms Ammunition Armour Piercing, Mr. Fredrik Eringe, Nammo Talley 12818 - Tracer...Ammunition Armour Piercing Mr. Fredrik Eringe, Nammo Talley SMALL ARMS SYSTEMS AGENDA: 05/25/11 2:40 pm - 3:10 pm BREAK - EXHIBIT HALL 3:10 pm - 4:50...inroads within the academic community by way of word-of-mouth advertisement at the faculty and the student level  Ability to sponsor needed research

  8. Treatment and Management of Closed or Inactive Small Arms Firing Ranges

    National Research Council Canada - National Science Library

    Larson, Steven L; Teeter, Cynthia L; Medina, Victor F; Martin, W. A

    2007-01-01

    This document provides environmental professionals and project managers with information on the effect of range type and soil type on technology selection for one-time cleanup of closed Small Arms Firing Ranges (SAFRs...

  9. Have Third-World Arms Industries Reduced Arms Imports?

    OpenAIRE

    Looney, R.E.

    1989-01-01

    Current Research on Peace and Violence, no. 1, 1989. Refereed Journal Article In 1945 only Argentina, Brazil, India and South Africa in the Third World possessed domestic arms industries which produced weapons systems other than small arms and ammunition (SIPRI, 1987, 76).

  10. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  11. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  12. Study on Small Arms Fire Training Platform%轻武器射击训练平台研究

    Institute of Scientific and Technical Information of China (English)

    杨育兵

    2011-01-01

    轻武器通常指可由单兵或班组携行战斗的武器,主要包括各种枪械,单兵面杀伤武器、便携式反坦克武器和单兵防空导弹等,在各国的武器装备里品种和数量最多,是近距离内杀伤敌人主要武器。随着信息化战争发展,轻武器射击训练也要随着信息化的建设,走出传统的训练模式,适应信息化对现代战争的影响。着重分析了传统射击训练存在的问题,采用模拟仿真技术,建设轻武器射击训练平台,探讨信息化条件下轻武器射击训练的方法路子。%Small arms are mainly used for short-range firing around the world.Each country has large quantity as well as various kinds of small arms.With the development of information warfare,small arms fire training should also be developed to meet the modern needs.This paper analyzes the problems in traditional shooting practice.In order to improve our country's capability in information warfare,this paper also proposes the use of the simulation technology in building a modern small arms fire training platform.

  13. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  14. Pick-up, transport and release of a molecular cargo using a small-molecule robotic arm

    Science.gov (United States)

    Kassem, Salma; Lee, Alan T. L.; Leigh, David A.; Markevicius, Augustinas; Solà, Jordi

    2016-02-01

    Modern-day factory assembly lines often feature robots that pick up, reposition and connect components in a programmed manner. The idea of manipulating molecular fragments in a similar way has to date only been explored using biological building blocks (specifically DNA). Here, we report on a wholly artificial small-molecule robotic arm capable of selectively transporting a molecular cargo in either direction between two spatially distinct, chemically similar, sites on a molecular platform. The arm picks up/releases a 3-mercaptopropanehydrazide cargo by formation/breakage of a disulfide bond, while dynamic hydrazone chemistry controls the cargo binding to the platform. Transport is controlled by selectively inducing conformational and configurational changes within an embedded hydrazone rotary switch that steers the robotic arm. In a three-stage operation, 79-85% of 3-mercaptopropanehydrazide molecules are transported in either (chosen) direction between the two platform sites, without the cargo at any time fully dissociating from the machine nor exchanging with other molecules in the bulk.

  15. Validation of the NATO Armaments Ballistic Kernel for use in small-arms fire control systems

    Directory of Open Access Journals (Sweden)

    D. Corriveau

    2017-06-01

    Full Text Available In support for the development of a new small-arm ballistic computer based on the NATO Armaments Ballistic Kernel (NABK for the Canadian snipers, DRDC Valcartier Research Centre was asked to carry out high-fidelity 6 degree-of-freedom (6-DOF trajectory simulations for a set of relevant vignettes for the snipers, and to compare the direct fire 6-DOF simulation results with those obtained with the 4-DOF NATO Armaments Ballistic Kernel (NABK adapted to simulate small-arm ammunition trajectories. To conduct this study, DRDC Valcartier Research Centre used BALCO v1.0b. This paper presents (1 the process and the methodology employed to carry out the sniper direct fire solution study, (2 the modeling and the simulation of the sniper projectile, the approach used in calculating the firing solutions, and the results of direct fire simulations for the sniper vignettes, and (3 an analysis of firing solutions obtained with the BALCO engine versus those of NABK. The work presented in this paper serves to validate the use of NABK for the new sniper ballistic computer.

  16. The Proliferation and Illicit Trafficking of Small Arms and Light Weapons in the Great Lakes and Horn of Africa

    National Research Council Canada - National Science Library

    Kiugu, Aphaxard M

    2007-01-01

    In Africa, the effect of the proliferation of small arms and light weapons (SALW) continues to impact negatively on socioeconomic development, particularly within the Great Lakes and Horn of Africa...

  17. Small supernumerary marker chromosome derived from proximal p-arm of chromosome 2: identification by fluorescent in situ hybridization.

    Science.gov (United States)

    Lasan Trcić, Ruzica; Hitrec, Vlasta; Letica, Ljiljana; Cuk, Mario; Begović, Davor

    2003-08-01

    Conventional cytogenetics detected an interstitial deletion of proximal region of p-arm of chromosome 2 in a 6-month-old boy with a phenotype slightly resembling Down's syndrome. The deletion was inherited from the father, whose karyotype revealed a small ring-shaped marker chromosome, in addition to interstitial deletion. Fluorescence in situ hybridization identified the marker, which consisted of the proximal region of the p-arm of chromosome 2, including a part of its centromere. This case shows that molecular cytogenetic analysis can reveal the mechanism of the formation of the marker chromosome.

  18. FY1995 development of artificial arm 'SMART ARM' by spherical ultrasonic motor; 1995 nendo kyumen choonpa motor wo mochiita jinko gishu smart arm no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project has an intention of development of new type artificial arm by spherical ultrasonic motor. We have succeeded in developing new type of spherical ultrasonic motor with three DOF. And we have succeeded in applying the motor to an artificial arm. This arm have advantages of small size, low weight torque comparing with conventional ones. We demonstrated them the new arm behaved well and it had good controlabilty. (NEDO)

  19. Small Arms Proliferation and Homegrown Terrorism in the Great Lakes Region: Uganda’s Experience

    Science.gov (United States)

    2016-12-01

    in Karamoja was also motivated by the low standard of living there, as the colonial administration and other entrepreneurs expropriated their land...facilitate homegrown terrorism. Because of porous borders that make it easier for potentially disruptive groups to cross into the country, the Act makes it...used by homegrown terrorists and conflicts in the region.209 Conflict entrepreneurs continue to profit from illegal small arms trade taking advantage

  20. Amrubicin therapy improves patients with refractory small-cell lung cancer: A single-arm confirmatory Chinese clinical study

    Directory of Open Access Journals (Sweden)

    Mengli Zheng

    2016-09-01

    Full Text Available Our objective was to evaluate an open-label, multicenter, single-arm study to appraise whether amrubicin therapy improves patients with refractory small-cell lung cancer in Chinese clinical study. Patients (n=95 with refractory small-cell lung cancer received 3 consecutive days amrubicin therapy for 21 days. Overall response rate of response to amrubicin was 39%. Anemia, febrile neutropenia, thrombocytopenia, hyperglycemia, hyponatremia, infection, elevated serum transaminases levels were appeared, but the incidences of adverse events were very few. Our results suggest amrubicin therapy can improve patients with refractory small-cell lung cancer and may be an effective and safe treatment option.

  1. Limited consensus around ARM information protection practices ...

    African Journals Online (AJOL)

    An existing enterprise IP SoP was adapted to ARM through literature analysis and produced a draft ARM SoP. The draft ARM SoP was applied in a rote fashion to a small sample of government-operated archives to identify likely areas of consensus and lack of consensus surrounding the various elements of the SoP.

  2. 33 CFR 334.1420 - Pacific Ocean off Orote Point, Apra Harbor, Island of Guam, Marianas Islands; small arms firing...

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Pacific Ocean off Orote Point, Apra Harbor, Island of Guam, Marianas Islands; small arms firing range. 334.1420 Section 334.1420... AND RESTRICTED AREA REGULATIONS § 334.1420 Pacific Ocean off Orote Point, Apra Harbor, Island of Guam...

  3. Model for small arms fire muzzle blast wave propagation in air

    Science.gov (United States)

    Aguilar, Juan R.; Desai, Sachi V.

    2011-11-01

    Accurate modeling of small firearms muzzle blast wave propagation in the far field is critical to predict sound pressure levels, impulse durations and rise times, as functions of propagation distance. Such a task being relevant to a number of military applications including the determination of human response to blast noise, gunfire detection and localization, and gun suppressor design. Herein, a time domain model to predict small arms fire muzzle blast wave propagation is introduced. The model implements a Friedlander wave with finite rise time which diverges spherically from the gun muzzle. Additionally, the effects in blast wave form of thermoviscous and molecular relaxational processes, which are associated with atmospheric absorption of sound were also incorporated in the model. Atmospheric absorption of blast waves is implemented using a time domain recursive formula obtained from numerical integration of corresponding differential equations using a Crank-Nicholson finite difference scheme. Theoretical predictions from our model were compared to previously recorded real world data of muzzle blast wave signatures obtained by shooting a set different sniper weapons of varying calibers. Recordings containing gunfire acoustical signatures were taken at distances between 100 and 600 meters from the gun muzzle. Results shows that predicted blast wave slope and exponential decay agrees well with measured data. Analysis also reveals the persistency of an oscillatory phenomenon after blast overpressure in the recorded wave forms.

  4. Arms Races and Negotiations

    OpenAIRE

    Sandeep Baliga; Tomas Sjostrom

    2003-01-01

    Two players simultaneously decide whether or not to acquire new weapons in an arms race game. Each player's type determines his propensity to arm. Types are private information, and are independently drawn from a continuous distribution. With probability close to one, the best outcome for each player is for neither to acquire new weapons (although each prefers to acquire new weapons if he thinks the opponent will). There is a small probability that a player is a dominant strategy type who alw...

  5. Arms Trafficking and Colombia

    National Research Council Canada - National Science Library

    Cragin, Kim; Hoffman, Bruce

    2003-01-01

    ... to traditional definitions of a security threat. For this analysis, the term "small arms" refers to man-portable personal and military weapons, ranging from handguns to assault rifles to surface-to-air missiles (SAMs...

  6. Passive Reactive Berm to Provide Low Maintenance Lead Containment at Active Small Arms Firing Ranges: Field Demonstration

    Science.gov (United States)

    2012-08-01

    Containment at Active Small Arms Firing Ranges Field Demonstration E nv ir on m en ta l L ab or at or y Michelle Wynter, Steven L. Larson, W.A...efficiency of 37 to 100 percent can be achieved through the process of hydroxyapatite dissolution and hydroxypyromorphite [Pb10(PO4)6(OH)2...al. 2006; Tardy et al. 2003; USEPA 2001a). Application of soluble or solid phase phosphate (such as hydroxyapatite , HAP) amendments have been shown

  7. Nonparetic arm force does not overinhibit the paretic arm in chronic poststroke hemiparesis.

    Science.gov (United States)

    Dimyan, Michael A; Perez, Monica A; Auh, Sungyoung; Tarula, Erick; Wilson, Matthew; Cohen, Leonardo G

    2014-05-01

    To determine whether nonparetic arm force overinhibits the paretic arm in patients with chronic unilateral poststroke hemiparesis. Case-control neurophysiological and behavioral study of patients with chronic stroke. Research institution. Eighty-six referred patients were screened to enroll 9 participants (N=9) with a >6 month history of 1 unilateral ischemic infarct that resulted in arm hemiparesis with residual ability to produce 1Nm of wrist flexion torque and without contraindication to transcranial magnetic stimulation. Eight age- and handedness-matched healthy volunteers without neurologic diagnosis were studied for comparison. Not applicable. Change in interhemispheric inhibition targeting the ipsilesional primary motor cortex (M1) during nonparetic arm force. We hypothesized that interhemispheric inhibition would increase more in healthy controls than in patients with hemiparesis. Healthy age-matched controls had significantly greater increases in inhibition from their active to resting M1 than patients with stroke from their active contralesional to resting ipsilesional M1 in the same scenario (20%±7% vs -1%±4%, F1,12=6.61, P=.025). Patients with greater increases in contralesional to ipsilesional inhibition were better performers on the 9-hole peg test of paretic arm function. Our findings reveal that producing force with the nonparetic arm does not necessarily overinhibit the paretic arm. Though our study is limited in generalizability by the small sample size, we found that greater active contralesional to resting ipsilesional M1 inhibition was related with better recovery in this subset of patients with chronic poststroke. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. The Development of light-weight 2-link robot arm for high radiation area

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Cheol; Seo, Yong Chil; Jung, Kyung Min; Choi, Young Soo

    2009-10-15

    A light-weight 2-link robot arm which weight is less than 8kg was developed for treating the small radio-active material in the high radiation area such as nuclear power plants and NDT area. The light-weight 2-link robot arm can be attached on a small mobile robot and carry out tasks. It is a 5 DOF robot arm including a gripper

  9. Implementation of double-C-arm synchronous real-time X-ray positioning system computer aided for aspiration biopsy of small lung lesion

    International Nuclear Information System (INIS)

    Zhu Hong; Wang Dong; Ye Yukun; Zhou Yuan; Lu Jianfeng; Yang Jingyu; Wang Lining

    2007-01-01

    Objective: To evaluate the feasibility of a new type of real-time three-dimensional X-ray positioning system for aspiration biopsy of small lung lesions. Methods: Using X-ray imaging technology and X-ray collimator technology and combining with double-C-arm X-ray machine, two different synchronous real-time images were obtained from the vertical to the horizontal plane. Then, with the computer image processing and computer vision processing technologies, dynamic tracking for 3D information of a pulmonary lesion and the needle in aspiration, and the relative position of the two, were established. Results: There was no interference while the two imaging perpendicularly X-ray beam met, two synchronous real-time image acquisition and tracking of a lung lesion and a needle could be completed in free respiration. The average positioning system error was about 0.5 mm, the largest positioning error was about 1.0 mm, real-time display rate was 5 screen/sec. Conclusions: the establishment of a new type of double-C-arm synchronous real-time X-ray positioning system is feasible. It is available for the fast and accurate aspiration biopsy of small lung lesions. (authors)

  10. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation.

    Science.gov (United States)

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies.

  11. ATLAS software stack on ARM64

    CERN Document Server

    Smith, Joshua Wyatt; The ATLAS collaboration

    2016-01-01

    The ATLAS experiment explores new hardware and software platforms that, in the future, may be more suited to its data intensive workloads. One such alternative hardware platform is the ARM architecture, which is designed to be extremely power efficient and is found in most smartphones and tablets. CERN openlab recently installed a small cluster of ARM 64-bit evaluation prototype servers. Each server is based on a single-socket ARM 64-bit system on a chip, with 32 Cortex-A57 cores. In total, each server has 128 GB RAM connected with four fast memory channels. This paper reports on the port of the ATLAS software stack onto these new prototype ARM64 servers. This included building the "external" packages that the ATLAS software relies on. Patches were needed to introduce this new architecture into the build as well as patches that correct for platform specific code that caused failures on non-x86 architectures. These patches were applied such that porting to further platforms will need no or only very little adj...

  12. Decommissioning and Environmental Cleanup of a Small Arms Training Facility - 13225

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Karen M. [United States Department of Energy - Savannah River Operations Office (United States); Kmetz, Thomas F.; Smith, Sandra B.; Blount, Gerald C. [Savannah River Nuclear Solutions, LLC (United States)

    2013-07-01

    US DOE performed a (CERCLA) non-time critical removal (NTCR) action at the Small Arms Training Area (SATA) Site Evaluation Area (SEA) located at the Savannah River Site (SRS), in Aiken, South Carolina. From 1951 to May 2010, the SATA was used as a small weapons practice and qualifying firing range. The SATA consisted of 870.1 ha (2,150 ac) of woodlands and open field, of which approximately 2.9 ha (7.3 ac) were used as a firing range. The SATA facility was comprised of three small arms ranges (one static and two interactive), storage buildings for supplies, a weapons cleaning building, and a control building. Additionally, a 113- m (370-ft) long earthen berm was used as a target backstop during live-fire exercises. The berm soils accumulated a large amount of spent lead bullets in the berm face during the facilities 59- years of operation. The accumulation of lead was such that soil concentrations exceeded the U.S. Environmental Protection Agency (USEPA) residential and industrial worker regional screening levels (RSLs). The RSL threshold values are based on standardized exposure scenarios that estimate contaminant concentrations in soil that the USEPA considers protective of humans over a lifetime. For the SATA facility, lead was present in soil at concentrations that exceed both the current residential (400 mg/kg) and industrial (800 mg/kg) RSLs. In addition, the concentration of lead in the soil exceeded the Toxicity Characteristic Leaching Procedure (TCLP) (40 Code of Federal Regulations [CFR] 261.24) regulatory limit. The TCLP analysis simulates landfill conditions and is designed to determine the mobility of contaminants in waste. In addition, a principal threat source material (PTSM) evaluation, human health risk assessment (HHRA), and contaminant migration (CM) analysis were conducted to evaluate soil contamination at the SATA SEA. This evaluation determined that there were no contaminants present that constitute PTSM and the CM analysis revealed that no

  13. CO(J = 2 - 1) study of molecular clouds in the southwest arm of M31

    International Nuclear Information System (INIS)

    Kutner, M.L.; Verter, F.; Rickard, L.J.

    1990-01-01

    The first map of M31 in the CO(J = 2 - 1) transition, covering a 3 arcmin by 3 arcmin section of the SW arm-interarm region, is presented. The CO spectra in the arm region defined by H II regions are characterized by strong, narrow features which are interpreted here to be giant molecular clouds with masses of a few 100,000 solar masses. The interarm emission is interpreted as an ensemble of small clouds with masses of a few 10,000 solar masses. On the arm about 70 percent of the emission comes from large clouds, while off the arm essentially all of it comes from small clouds. The mass surface density on this section of M31 is about that of a comparable section of the Scutum arm of the Galaxy. The velocities of the giant clouds in the arm are shifted with respect to the rest of the molecular and atomic gas by about 15 km/s. This may be due to cloud response to passage through the spiral arm potential. 49 refs

  14. Planet-driven Spiral Arms in Protoplanetary Disks. I. Formation Mechanism

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    Protoplanetary disk simulations show that a single planet can excite more than one spiral arm, possibly explaining the recent observations of multiple spiral arms in some systems. In this paper, we explain the mechanism by which a planet excites multiple spiral arms in a protoplanetary disk. Contrary to previous speculations, the formation of both primary and additional arms can be understood as a linear process when the planet mass is sufficiently small. A planet resonantly interacts with epicyclic oscillations in the disk, launching spiral wave modes around the Lindblad resonances. When a set of wave modes is in phase, they can constructively interfere with each other and create a spiral arm. More than one spiral arm can form because such constructive interference can occur for different sets of wave modes, with the exact number and launching position of the spiral arms being dependent on the planet mass as well as the disk temperature profile. Nonlinear effects become increasingly important as the planet mass increases, resulting in spiral arms with stronger shocks and thus larger pitch angles. This is found to be common for both primary and additional arms. When a planet has a sufficiently large mass (≳3 thermal masses for (h/r) p = 0.1), only two spiral arms form interior to its orbit. The wave modes that would form a tertiary arm for smaller mass planets merge with the primary arm. Improvements in our understanding of the formation of spiral arms can provide crucial insights into the origin of observed spiral arms in protoplanetary disks.

  15. Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task.

    Directory of Open Access Journals (Sweden)

    Kazuyoshi Kigawa

    Full Text Available Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant's view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70-80 Hz vibration to the elbow flexors of the reference arm (= right arm to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.

  16. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, Kengo; Lin, Chia Hui [Department of Earth and Space Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Machida, Masahiro N. [Department of Earth and Planetary Sciences, Faculty of Sciences, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Hosokawa, Takashi [Department of Physics, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan); Sakurai, Yuya, E-mail: tomida@vega.ess.sci.osaka-u.ac.jp [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan)

    2017-01-20

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  17. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    International Nuclear Information System (INIS)

    Tomida, Kengo; Lin, Chia Hui; Machida, Masahiro N.; Hosokawa, Takashi; Sakurai, Yuya

    2017-01-01

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  18. Captive spider monkeys (Ateles geoffroyi) arm-raise to solicit allo-grooming.

    Science.gov (United States)

    Scheel, Matthew H; Edwards, Dori

    2012-03-01

    Old World monkeys solicit allo-grooming from conspecifics. However, there are relatively few studies of allo-grooming among spider monkeys, and descriptions of allo-grooming solicitation among spider monkeys are anecdotal. In this study, eighty-one hours of video, shot over eight weeks, captured 271 allo-grooming bouts among small groups of captive spider monkeys. Six of eight monkeys made heretofore unreported arm-raises that solicited higher than normal rates of allo-grooming. Allo-grooming bout durations following arm-raises also tended to be longer than bouts not preceded by arm-raises. The efficacy of the arm-raise at soliciting allo-grooming suggests spider monkeys are capable of intentional communication. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Diazo Reagents with Small Steric Footprints for Simultaneous Arming/SAR Studies of Alcohol-Containing Natural Products via O–H Insertion

    Science.gov (United States)

    Chamni, Supakarn; He, Qing-Li; Dang, Yongjun; Bhat, Shridhar; Liu, Jun O.; Romo, Daniel

    2011-01-01

    Natural products are essential tools for basic cellular studies leading to the identification of medically relevant protein targets and the discovery of potential therapeutic leads. The development of methods that enable mild and selective derivatization of natural products continues to be of significant interest for mining their information-rich content. Herein, we describe novel diazo reagents for simultaneous arming and structure-activity relationship (SAR) studies of alcohol-containing natural products with a small steric footprint, namely an α-trifluoroethyl (HTFB) substituted reagent. The Rh(II)-catalyzed O–H insertion reaction of several natural products, including the potent translation inhibitor lactimidomycin, was investigated and useful reactivity and both chemo- and site (chemosite) selectivities were observed. Differential binding to the known protein targets of both FK506 and fumagillol was demonstrated, validating the advantage of the smaller steric footprint of trifluoroethyl derivatives. A p-azidophenyl diazo reagent is also described that will prove useful for photoaffinity labeling of low affinity small molecule protein receptors. PMID:21894934

  20. The Arms Trade and States' Duty to Ensure Respect for Humanitarian and Human Rights Law

    DEFF Research Database (Denmark)

    Brehm, Maya

    2007-01-01

    transfers has traditionally been treated as a question of arms control law, but in the recent debate about legal restrictions on states' liberty to transfer arms, norms of international humanitarian and human rights law have frequently been invoked. This article surveys the existing international legal......The unregulated international trade in conventional arms, especially in small arms and light weapons, has come to be viewed as an exacerbating factor in armed conflict, violent crime and internal repression. Concern about the negative humanitarian, development and security impact of this trade has...... been growing over the last decade. Against this backdrop, the UN General Assembly invited states in December 2006 to consider the feasibility of an instrument establishing common international standards for conventional arms transfers-also known as the ‘Arms Trade Treaty' (ATT). The legality of arms...

  1. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [National Research Council Canada, National Science Infrastructure portfolio, Herzberg Astronomy and Astrophysics, 5071 West Saanich Road, Victoria, B.C., V9E 2E7 (Canada)

    2014-07-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  2. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  3. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments.

    Science.gov (United States)

    Morita, Hironobu; Obata, Koji; Abe, Chikara; Shiba, Dai; Shirakawa, Masaki; Kudo, Takashi; Takahashi, Satoru

    2015-01-01

    To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments.

  4. Structural Studies of Three-Arm Star Block Copolymers Exposed to Extreme Stretch Suggests a Persistent Polymer Tube

    Science.gov (United States)

    Mortensen, Kell; Borger, Anine L.; Kirkensgaard, Jacob J. K.; Garvey, Christopher J.; Almdal, Kristoffer; Dorokhin, Andriy; Huang, Qian; Hassager, Ole

    2018-05-01

    We present structural small-angle neutron scattering studies of a three-armed polystyrene star polymer with short deuterated segments at the end of each arm. We show that the form factor of the three-armed star molecules in the relaxed state agrees with that of the random phase approximation of Gaussian chains. Upon exposure to large extensional flow conditions, the star polymers change conformation resulting in a highly stretched structure that mimics a fully extended three-armed tube model. All three arms are parallel to the flow, one arm being either in positive or negative stretching direction, while the two other arms are oriented parallel, right next to each other in the direction opposite to the first arm.

  5. Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

    Science.gov (United States)

    Snead, C. J.; Jang, J. H.; Cowden, T. R.; McCubbin, F. M.

    2018-01-01

    The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with

  6. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  7. Arm dominance affects feedforward strategy more than feedback sensitivity during a postural task.

    Science.gov (United States)

    Walker, Elise H E; Perreault, Eric J

    2015-07-01

    Handedness is a feature of human motor control that is still not fully understood. Recent work has demonstrated that the dominant and nondominant arm each excel at different behaviors and has proposed that this behavioral asymmetry arises from lateralization in the cerebral cortex: the dominant side specializes in predictive trajectory control, while the nondominant side is specialized for impedance control. Long-latency stretch reflexes are an automatic mechanism for regulating posture and have been shown to contribute to limb impedance. To determine whether long-latency reflexes also contribute to asymmetric motor behavior in the upper limbs, we investigated the effect of arm dominance on stretch reflexes during a postural task that required varying degrees of impedance control. Our results demonstrated slightly but significantly larger reflex responses in the biarticular muscles of the nondominant arm, as would be consistent with increased impedance control. These differences were attributed solely to higher levels of voluntary background activity in the nondominant biarticular muscles, indicating that feedforward strategies for postural stability may differ between arms. Reflex sensitivity, which was defined as the magnitude of the reflex response for matched levels of background activity, was not significantly different between arms for a broad subject population ranging from 23 to 51 years of age. These results indicate that inter-arm differences in feedforward strategies are more influential during posture than differences in feedback sensitivity, in a broad subject population. Interestingly, restricting our analysis to subjects under 40 years of age revealed a small increase in long-latency reflex sensitivity in the nondominant arm relative to the dominant arm. Though our subject numbers were small for this secondary analysis, it suggests that further studies may be required to assess the influence of reflex lateralization throughout development.

  8. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments.

    Directory of Open Access Journals (Sweden)

    Hironobu Morita

    Full Text Available To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments.

  9. Isolated effects of peripheral arm and central body cooling on arm performance.

    Science.gov (United States)

    Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K

    1995-10-01

    Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.

  10. An ARM Mobile Facility Designed for Marine Deployments

    Science.gov (United States)

    Wiscombe, W. J.

    2007-05-01

    The U.S. Dept. of Energy's ARM (Atmospheric Radiation Measurements) Program is designing a Mobile Facility exclusively for marine deployments. This marine facility is patterned after ARM's land Mobile Facility, which had its inaugural deployment at Point Reyes, California, in 2005, followed by deployments to Niger in 2006 and Germany in 2007 (ongoing), and a planned deployment to China in 2008. These facilities are primarily intended for the study of clouds, radiation, aerosols, and surface processes with a goal to include these processes accurately in climate models. They are preferably embedded within larger field campaigns which provide context. They carry extensive instrumentation (in several large containers) including: cloud radar, lidar, microwave radiometers, infrared spectrometers, broadband and narrowband radiometers, sonde-launching facilities, extensive surface aerosol measurements, sky imagers, and surface latent and sensible heat flux devices. ARM's Mobile Facilities are designed for 6-10 month deployments in order to capture climatically-relevant datasets. They are available to any scientist, U.S. or international, who wishes to submit a proposal during the annual Spring call. The marine facility will be adapted to, and ruggedized for, the harsh marine environment and will add a scanning two-frequency radar, a boundary-layer wind profiler, a shortwave spectrometer, and aerosol instrumentation adapted to typical marine aerosols like sea salt. Plans also include the use of roving small UAVs, automated small boats, and undersea autonomous vehicles in order to address the point-to-area-average problem which is so crucial for informing climate models. Initial deployments are planned for small islands in climatically- interesting cloud regimes, followed by deployments on oceanic platforms (like decommissioned oil rigs and the quasi-permanent platform of this session's title) and eventually on large ships like car carriers plying routine routes.

  11. Arm Pain

    Science.gov (United States)

    ... be a sign of a heart attack. Seek emergency treatment if you have: Arm, shoulder or back ... http://www.mayoclinic.org/symptoms/arm-pain/basics/definition/SYM-20050870 . Mayo Clinic Footer Legal Conditions and ...

  12. Effect of slow, small movement on the vibration-evoked kinesthetic illusion.

    Science.gov (United States)

    Cordo, P J; Gurfinkel, V S; Brumagne, S; Flores-Vieira, C

    2005-12-01

    The study reported in this paper investigated how vibration-evoked illusions of joint rotation are influenced by slow (0.3 degrees /s), small (2-4 degrees ) passive rotation of the joint. Normal human adults (n=15) matched the perceived position of the left ("reference") arm with the right ("matching") arm while vibration (50 pps, 0.5 mm) was applied for 30 s to the relaxed triceps brachii of the reference arm. Both arms were constrained to rotate horizontally at the elbow. Three experimental conditions were investigated: (1) vibration of the stationary reference arm, (2) slow, small passive extension or flexion of the reference arm during vibration, and (3) slow, small passive extension or flexion of the reference arm without vibration. Triceps brachii vibration at 50 pps induced an illusion of elbow flexion. The movement illusion began after several seconds, relatively fast to begin with and gradually slowing down to a stop. On average, triceps vibration produced illusory motion at an average latency of 6.3 s, amplitude of 9.7 degrees , velocity of 0.6 degrees /s, and duration of 16.4 s. During vibration, slow, small ( approximately 0.3 degrees /s, 1.3 degrees ) passive rotations of the joint dramatically enhanced, stopped, or reversed the direction of illusory movement, depending on the direction of the passive joint rotation. However, the subjects' perceptions of these passive elbow rotations were exaggerated: 2-3 times the size of the actual movement. In the absence of vibration, the subjects accurately reproduced these passive joint rotations. We discuss whether the exaggerated perception of slow, small movement during vibration is better explained by contributions of non muscle spindle Ia afferents or by changes in the mechanical transmission of vibration to the receptor.

  13. The Effects of Lever Arm (Instrument Offset) Error on GRAV-D Airborne Gravity Data

    Science.gov (United States)

    Johnson, J. A.; Youngman, M.; Damiani, T.

    2017-12-01

    High quality airborne gravity collection with a 2-axis, stabilized platform gravity instrument, such as with a Micro-g LaCoste Turnkey Airborne Gravity System (TAGS), is dependent on the aircraft's ability to maintain "straight and level" flight. However, during flight there is constant rotation about the aircraft's center of gravity. Standard practice is to install the scientific equipment close to the aircraft's estimated center of gravity to minimize the relative rotations with aircraft motion. However, there remain small offsets between the instruments. These distance offsets, the lever arm, are used to define the rigid-body, spatial relationship between the IMU, GPS antenna, and airborne gravimeter within the aircraft body frame. The Gravity for the Redefinition of the American Vertical Datum (GRAV-D) project, which is collecting airborne gravity data across the U.S., uses a commercial software package for coupled IMU-GNSS aircraft positioning. This software incorporates a lever arm correction to calculate a precise position for the airborne gravimeter. The positioning software must do a coordinate transformation to relate each epoch of the coupled GNSS-IMU derived position to the position of the gravimeter within the constantly-rotating aircraft. This transformation requires three inputs: accurate IMU-measured aircraft rotations, GNSS positions, and lever arm distances between instruments. Previous studies show that correcting for the lever arm distances improves gravity results, but no sensitivity tests have been done to investigate how error in the lever arm distances affects the final airborne gravity products. This research investigates the effects of lever arm measurement error on airborne gravity data. GRAV-D lever arms are nominally measured to the cm-level using surveying equipment. "Truth" data sets will be created by processing GRAV-D flight lines with both relatively small lever arms and large lever arms. Then negative and positive incremental

  14. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  15. A 3' UTR-Derived Small RNA Provides the Regulatory Noncoding Arm of the Inner Membrane Stress Response.

    Science.gov (United States)

    Chao, Yanjie; Vogel, Jörg

    2016-02-04

    Small RNAs (sRNAs) from conserved noncoding genes are crucial regulators in bacterial signaling pathways but have remained elusive in the Cpx response to inner membrane stress. Here we report that an alternative biogenesis pathway releasing the conserved mRNA 3' UTR of stress chaperone CpxP as an ∼60-nt sRNA provides the noncoding arm of the Cpx response. This so-called CpxQ sRNA, generated by general mRNA decay through RNase E, acts as an Hfq-dependent repressor of multiple mRNAs encoding extracytoplasmic proteins. Both CpxQ and the Cpx pathway are required for cell survival under conditions of dissipation of membrane potential. Our discovery of CpxQ illustrates how the conversion of a transcribed 3' UTR into an sRNA doubles the output of a single mRNA to produce two factors with spatially segregated functions during inner membrane stress: a chaperone that targets problematic proteins in the periplasm and a regulatory RNA that dampens their synthesis in the cytosol. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The EU’s Open Arms and Small States

    Directory of Open Access Journals (Sweden)

    Thorvaldur Gylfason

    2016-05-01

    Full Text Available The EU has fostered lasting peace and prosperity in Europe since World War II and welcomed formerly autocratic countries back into the European fold. The paper describes the EU as a union of primarily small European states whose parallel emphasis on efficiency and fairness, including deep respect for human rights, holds the key to Europe´s economic and social advances. While expansion fatigue has temporarily slowed the momentum of the widening of European unification, the EU can expect to benefit from welcoming more small states as members, including Albania and Iceland as well as Catalonia and Scotland should they declare independence.

  17. Measurement Capabilities of the DOE ARM Aerial Facility

    Science.gov (United States)

    Schmid, B.; Tomlinson, J. M.; Hubbe, J.; Comstock, J. M.; Kluzek, C. D.; Chand, D.; Pekour, M. S.

    2012-12-01

    The Department of Energy Atmospheric Radiation Measurement (ARM) Program is a climate research user facility operating stationary ground sites in three important climatic regimes that provide long-term measurements of climate relevant properties. ARM also operates mobile ground- and ship-based facilities to conduct shorter field campaigns (6-12 months) to investigate understudied climate regimes around the globe. Finally, airborne observations by ARM's Aerial Facility (AAF) enhance the surface-based ARM measurements by providing high-resolution in situ measurements for process understanding, retrieval algorithm development, and model evaluation that is not possible using ground-based techniques. AAF started out in 2007 as a "virtual hangar" with no dedicated aircraft and only a small number of instruments owned by ARM. In this mode, AAF successfully carried out several missions contracting with organizations and investigators who provided their research aircraft and instrumentation. In 2009, the Battelle owned G-1 aircraft was included in the ARM facility. The G-1 is a large twin turboprop aircraft, capable of measurements up to altitudes of 7.5 km and a range of 2,800 kilometers. Furthermore the American Recovery and Reinvestment Act of 2009 provided funding for the procurement of seventeen new instruments to be used aboard the G-1 and other AAF virtual-hangar aircraft. AAF now executes missions in the virtual- and real-hangar mode producing freely available datasets for studying aerosol, cloud, and radiative processes in the atmosphere. AAF is also heavily engaged in the maturation and testing of newly developed airborne sensors to help foster the next generation of airborne instruments. In the presentation we will showcase science applications based on measurements from recent field campaigns such as CARES, CALWATER and TCAP.

  18. ARM Airborne Carbon Measurements (ARM-ACME) and ARM-ACME 2.5 Final Campaign Reports

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, S. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tom, M. S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, C. [NOAA Earth Systems Research Lab., Boulder, CO (United States)

    2016-01-01

    We report on a 5-year multi-institution and multi-agency airborne study of atmospheric composition and carbon cycling at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, with scientific objectives that are central to the carbon-cycle and radiative-forcing goals of the U.S. Global Change Research Program and the North American Carbon Program (NACP). The goal of these measurements is to improve understanding of 1) the carbon exchange of the Atmospheric Radiation Measurement (ARM) SGP region; 2) how CO2 and associated water and energy fluxes influence radiative-forcing, convective processes, and CO2 concentrations over the ARM SGP region, and 3) how greenhouse gases are transported on continental scales.

  19. Powered manipulator control arm

    International Nuclear Information System (INIS)

    Le Mouee, Theodore; Vertut, Jean; Marchal, Paul; Germon, J.C.; Petit, Michel

    1975-01-01

    A remote operated control arm for powered manipulators is described. It includes an assembly allowing several movements with position sensors for each movement. The number of possible arm movements equals the number of possible manipulator movements. The control systems may be interrupted as required. One part of the arm is fitted with a system to lock it with respect to another part of the arm without affecting the other movements, so long as the positions of the manipulator and the arm have not been brought into complete coincidence. With this system the locking can be ended when complete concordance is achieved [fr

  20. ARM Airborne Carbon Measurements VI (ARM-ACME VI) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, Sebastien [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-01

    From October 1, 2015 through September 30, 2016, AAF deployed a Cessna 206 aircraft over the Southern Great Plains, collecting observations of trace gas mixing ratios over the ARM/SGP Central Facility. The aircraft payload included two Atmospheric Observing Systems (AOS Inc.) analyzers for continuous measurements of CO2, and a 12-flask sampler for analysis of carbon cycle gases (CO2, CO, CH4, N2O, 13CO2). The aircraft payload also includes solar/infrared radiation measurements. This research (supported by DOE ARM and TES programs) builds upon previous ARM-ACME missions. The goal of these measurements is to improve understanding of: (a) the carbon exchange of the ARM region; (b) how CO2 and associated water and energy fluxes influence radiative forcing, convective processes, and CO2 concentrations over the ARM region, and (c) how greenhouse gases are transported on continental scales.

  1. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  2. Morphological analysis of the hindlimb in apes and humans. II. Moment arms

    Science.gov (United States)

    Payne, R C; Crompton, R H; Isler, K; Savage, R; Vereecke, E E; Günther, M M; Thorpe, S K S; D'Août, K

    2006-01-01

    Flexion/extension moment arms were obtained for the major muscles crossing the hip, knee and ankle joints in the orang-utan, gibbon, gorilla (Eastern and Western lowland) and bonobo. Moment arms varied with joint motion and were generally longer in proximal limb muscles than distal limb muscles. The shape of the moment arm curves (i.e. the plots of moment arm against joint angle) differed in different hindlimb muscles and in the same muscle in different subjects (both in the same and in different ape species). Most moment arms increased with increasing joint flexion, a finding which may be understood in the context of the employment of flexed postures by most non-human apes (except orang-utans) during both terrestrial and arboreal locomotion. When compared with humans, non-human great apes tended to have muscles better designed for moving the joints through large ranges. This was particularly true of the pedal digital flexors in orang-utans. In gibbons, the only lesser ape studied here, many of the moment arms measured were relatively short compared with those of great apes. This study was performed on a small sample of apes and thus differences noted here warrant further investigation in larger populations. PMID:16761974

  3. Reach and grasp by people with tetraplegia using a neurally controlled robotic arm

    Science.gov (United States)

    Hochberg, Leigh R.; Bacher, Daniel; Jarosiewicz, Beata; Masse, Nicolas Y.; Simeral, John D.; Vogel, Joern; Haddadin, Sami; Liu, Jie; Cash, Sydney S.; van der Smagt, Patrick; Donoghue, John P.

    2012-01-01

    Paralysis following spinal cord injury (SCI), brainstem stroke, amyotrophic lateral sclerosis (ALS) and other disorders can disconnect the brain from the body, eliminating the ability to carry out volitional movements. A neural interface system (NIS)1–5 could restore mobility and independence for people with paralysis by translating neuronal activity directly into control signals for assistive devices. We have previously shown that people with longstanding tetraplegia can use an NIS to move and click a computer cursor and to control physical devices6–8. Able-bodied monkeys have used an NIS to control a robotic arm9, but it is unknown whether people with profound upper extremity paralysis or limb loss could use cortical neuronal ensemble signals to direct useful arm actions. Here, we demonstrate the ability of two people with long-standing tetraplegia to use NIS-based control of a robotic arm to perform three-dimensional reach and grasp movements. Participants controlled the arm over a broad space without explicit training, using signals decoded from a small, local population of motor cortex (MI) neurons recorded from a 96-channel microelectrode array. One of the study participants, implanted with the sensor five years earlier, also used a robotic arm to drink coffee from a bottle. While robotic reach and grasp actions were not as fast or accurate as those of an able-bodied person, our results demonstrate the feasibility for people with tetraplegia, years after CNS injury, to recreate useful multidimensional control of complex devices directly from a small sample of neural signals. PMID:22596161

  4. ARM Mentor Selection Process

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, D. L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.

  5. Innovative Design of Plastic Bottle Recycling Box Based on ARM

    Directory of Open Access Journals (Sweden)

    Yuedong Xiong

    2014-04-01

    Full Text Available Aiming at the problems of on-site plastic bottles recycling and the reuse of waste, the automatic recycling system was developed on the basis of ARM. As the main controller, ARM not only controls the mechanical system of the collector to recover and break plastic bottles, but also communicates with and rewards the user by the automatic reward system through the wireless network. The experimental prototype test results show: post treated fragments of plastic bottles are small, which are convenient to transport and take advantage of; the operation of recovery is easy, and the interface of man-machine interaction is friendly which is easy to expand functions.

  6. The arms race control

    International Nuclear Information System (INIS)

    Nemo, J.

    2010-01-01

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  7. How do octopuses use their arms?

    Science.gov (United States)

    Mather, J A

    1998-09-01

    A taxonomy of the movement patterns of the 8 flexible arms of octopuses is constructed. Components consist of movements of the arm itself, the ventral suckers and their stalks, as well as the relative position of arms and the skin web between them. Within 1 arm, combinations of components result in a variety of behaviors. At the level of all arms, 1 group of behaviors is described as postures, on the basis of the spread of all arms and the web to make a 2-dimensional surface whose position differs in the 3rd dimension. Another group of arm behaviors is actions, more or less coordinated and involving several to all arms. Arm control appears to be based on radial symmetry, relative equipotentiality of all arms, relative independence of each arm, and separability of components within the arm. The types and coordination of arm behaviors are discussed with relationship to biomechanical limits, muscle structures, and neuronal programming.

  8. Lead Free Frangible Ammunition Exposure at United States Air Force Small Arms Firing Ranges, 2005 - 2007

    National Research Council Canada - National Science Library

    Moran, Michael P; Ott, Darrin K

    2008-01-01

    ...) has performed related to health concerns expressed by Security Forces Combat Arms (CATM) instructors regarding exposure to contaminants generated during the discharge of lead free frangible ammunition...

  9. Going with small ICBMs

    International Nuclear Information System (INIS)

    Arkin, W.M.

    1984-01-01

    Support for the small ICBM (SICBM) is coming from government bureaucrats, contractors, MX opponents, ''build-down'' supporters, and those who have no confidence in arms control. Despite this support, which the author sees as a failure of administration policies, the SICBM has most of the technological and basing drawbacks of the MX. Mobile and superhardening basing techniques are as questionable for the SICBM as for the MX. Moreover, there is no evidence to support the claim that their deployment will increase stability and enhance the arms control process

  10. CyARM: Haptic Sensing Device for Spatial Localization on Basis of Exploration by Arms

    Directory of Open Access Journals (Sweden)

    Junichi Akita

    2009-01-01

    Full Text Available We introduce a new type of perception aid device based on user's exploration action, which is named as CyARM (acronym of “Cyber Arm”. The user holds this device in her/his arm, the extension of the arm is controlled by tension in wires, which are attached to her/his body according to the distance to the object. This user interface has unique characteristics that give users the illusion of an imaginary arm that extends to existing objects. The implementations of CyARM and our two experiments to investigate the efficiency and effectiveness of CyARM are described. The results show that we could confirm that CyARM can be used to recognize the presence of an object in front of the user and to measure the relative distance to the object.

  11. Evaluation of field-portable X-ray fluorescence spectrometry for the determination of lead contamination on small-arms firing ranges

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.F.; Taylor, J.D.; Bass, D.A.; Zellmer, D. [Argonne National Lab., IL (United States); Rieck, M. [U.S. Army, Grafenwoehr Training Area (Germany)

    1995-02-01

    Field analytical methods for the characterization of lead contamination in soil are being developed. In this study, the usefulness of a commercially available, field-portable energy-dispersive X-ray fluorescence spectrometer (XRF) is evaluated for determining the extent of lead contamination in soils on small-arms firing ranges at a military installation. This field screening technique provides significant time and cost savings for the study of sites with lead-contaminated soil. Data obtained with the XRF unit in the field are compared with data obtained from soil samples analyzed in an analytical laboratory by inductively coupled plasma atomic emission spectroscopy. Results indicate that the field-portable XRF unit evaluated in this study provides data that are useful in determining the extent and relative magnitude of lead contamination. For the commercial unit used in this study, improvements in the spectral resolution and in the limit of detection would be required to make the unit more than just a screening tool.

  12. Development of induction current acquisition device based on ARM

    Science.gov (United States)

    Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan

    2018-03-01

    We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.

  13. ARM CLASIC ER2 CRS/EDOP

    Energy Technology Data Exchange (ETDEWEB)

    Gerald Heymsfield

    2010-12-20

    Data was taken with the NASA ER-2 aircraft with the Cloud Radar System and other instruments in conjunction with the DOE ARM CLASIC field campaign. The flights were near the SGP site in north Central Oklahoma and targeted small developing convection. The CRS is a 94 GHz nadir pointing Doppler radar. Also on board the ER-2 was the Cloud Physics Lidar (CPL). Seven science flights were conducted but the weather conditions did not cooperate in that there was neither developing convection, or there was heavy rain.

  14. Pragmatism and Effective Fragmented Governance: Comparing Trajectories in Small Arms and Military and Security Services

    Directory of Open Access Journals (Sweden)

    Deborah Avant

    2013-10-01

    Full Text Available A hallmark of contemporary global governance is its complex nature. Understanding the implications of the array of “governors” and their efforts is paramount for scholars of global law and global politics. Most analyses have treated fragmented governance as a piece, arguing about its general effects. I concentrate instead on variation within fragmented situations, seeking to understand the conditions under which complexity yields more or less effective governance. I propose an analytical scheme for gauging effectiveness focused on how the array of governance efforts in an issue area relate to one another. I then compare these efforts in two issue arenas: small arms and private military and security services. Despite a similar complexity, similar array of actors trying to exert influence, and similar timing, complexity in small arms generated what most see as less effective results while in military and security services it has generated what seems to be a more promising path toward effective governance mechanisms. This difference is best explained with insights from pragmatism and network theory. When a broader range of relevant governors engage pragmatically to form linked networks governance is more likely. When governors engage ideologically and break off ties governance is less likely. Pragmatic engagement among the variety of relevant governors, including the US, is most likely to generate effective global governance. Una característica distintiva del gobierno mundial contemporáneo es su naturaleza compleja. Entender las implicaciones de la serie de "gobernadores" y sus esfuerzos es fundamental para los estudiosos del derecho internacional y la política mundial. La mayoría de los análisis han tratado el gobierno fragmentado como una pieza, discutiendo sobre sus efectos generales. El análisis se centra en cambio en la variación dentro de situaciones fragmentadas, buscando entender las condiciones en las que la complejidad produce

  15. Can the large-scale magnetic field lines cross the spiral arms in our Milky Way galaxy?

    International Nuclear Information System (INIS)

    Vallee, J.P.

    1988-01-01

    For the Sgr, Ori, and Per spiral arms, the pitch angle (i.e., deviation from a tangent parallel to a circular orbit around the center of the Galaxy) of the magnetic-field lines differs from the pitch angle of the spiral arms. For the spiral arms, the pitch angle of the magnetic-field lines can be measured independently from both quasars and galaxies as well as from pulsars, yielding a small (-6 deg) pitch angle, as predicted in the roughly circular oval gas streamline model of the density-wave theory. Meanwhile, the pitch angle of the spiral arms can be measured independently from both the O type stars and from the H II regions, yielding a large (-18 deg) pitch angle, also as predicted in the density-wave theory. Thus for these arms, the magnetic-field lines cross the spiral arms, to leave them outwardly at a sizable mean angle (+12 deg). 19 references

  16. Exact positioning of the robotic arm end effector

    Science.gov (United States)

    Korepanov, Valery; Dudkin, Fedir

    2016-07-01

    Orbital service becomes a new challenge of space exploration. The necessity to introduce it is connected first of all with an attractive opportunity to prolong the exploitation terms of expensive commercial satellites by, e.g., refilling of fuel or changing batteries. Other application area is a fight with permanently increasing amount of space litter - defunct satellites, burnt-out rocket stages, discarded trash and other debris. Now more than few tens of thousands orbiting objects larger than 5-10 cm (or about 1 million junks larger than 1 cm) are a huge problem for crucial and costly satellites and manned vehicles. For example, in 2014 the International Space Station had to change three times its orbit to avoid collision with space debris. So the development of the concepts and actions related to removal of space debris or non-operational satellites with use of robotic arm of a servicing satellite is very actual. Such a technology is also applicable for unmanned exploratory missions in solar system, for example for collecting a variety of samples from a celestial body surface. Naturally, the robotic arm movements should be controlled with great accuracy at influence of its non-rigidity, thermal and other factors. In these circumstances often the position of the arm end effector has to be controlled with high accuracy. The possibility of coordinate determination for the robotic arm end effector with use of a low frequency active electromagnetic system has been considered in the presented report. The proposed design of such a system consists of a small magnetic dipole source, which is mounted inside of the arm end effector and two or three 3-component magnetic field sensors mounted on a servicing satellite body. The data from this set of 3-component magnetic field sensors, which are fixed relatively to the satellite body, allows use of the mathematical approach for determination of position and orientation of the magnetic dipole source. The theoretical

  17. Armed conflict and child health.

    Science.gov (United States)

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health throughout the world. One in six children worldwide lives in an area of armed conflict and civilians are more likely to die than soldiers as a result of the conflict. In stark contrast to the effect on children, the international arms trade results in huge profits for the large corporations involved in producing arms, weapons and munitions. Armed conflict is not inevitable but is an important health issue that should be prevented.

  18. Hello to Arms

    Science.gov (United States)

    2005-01-01

    This image highlights the hidden spiral arms (blue) that were discovered around the nearby galaxy NGC 4625 by the ultraviolet eyes of NASA's Galaxy Evolution Explorer. The image is composed of ultraviolet and visible-light data, from the Galaxy Evolution Explorer and the California Institute of Technology's Digitized Sky Survey, respectively. Near-ultraviolet light is colored green; far-ultraviolet light is colored blue; and optical light is colored red. As the image demonstrates, the lengthy spiral arms are nearly invisible when viewed in optical light while bright in ultraviolet. This is because they are bustling with hot, newborn stars that radiate primarily ultraviolet light. The youthful arms are also very long, stretching out to a distance four times the size of the galaxy's core. They are part of the largest ultraviolet galactic disk discovered so far. Located 31 million light-years away in the constellation Canes Venatici, NGC 4625 is the closest galaxy ever seen with such a young halo of arms. It is slightly smaller than our Milky Way, both in size and mass. However, the fact that this galaxy's disk is forming stars very actively suggests that it might evolve into a more massive and mature galaxy resembling our own. The armless companion galaxy seen below NGC 4625 is called NGC 4618. Astronomers do not know why it lacks arms but speculate that it may have triggered the development of arms in NGC 4625.

  19. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application.

    Science.gov (United States)

    Pan, Chao-Yu; Kuo, Wei-Ting; Chiu, Chien-Yuan; Lin, Wen-Chang

    2017-01-01

    MicroRNAs (miRNAs) play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA) miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  20. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application

    Directory of Open Access Journals (Sweden)

    Chao-Yu Pan

    2017-01-01

    Full Text Available MicroRNAs (miRNAs play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  1. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment

  2. Synchrotron X-ray scattering characterization of the molecular structures of star polystyrenes with varying numbers of arms.

    Science.gov (United States)

    Jin, Sangwoo; Higashihara, Tomoya; Jin, Kyeong Sik; Yoon, Jinhwan; Rho, Yecheol; Ahn, Byungcheol; Kim, Jehan; Hirao, Akira; Ree, Moonhor

    2010-05-20

    We have synthesized well-defined multiarmed star polystyrenes, with 6, 9, 17, 33, and 57 arms, and studied their molecular shapes and structural characteristics in a good solvent (tetrahydrofuran at 25 degrees C) and in a theta (Theta) solvent (cyclohexane at 35 degrees C) by small-angle X-ray scattering (SAXS) using a synchrotron radiation source. Analysis of the SAXS data provided a detailed characterization of the molecular shapes, including the contributions of the blob morphology of the arms, the radius of gyration, the paired distance distribution, the radial electron density distribution, and the Zimm-Stockmayer and Roovers g-factor, for the multiarmed star polystyrenes. In particular, the molecular shapes of the star polystyrenes were found to change from a fuzzy ellipsoid, for the 6-armed polystyrene, to a fuzzy sphere, for the 57-armed polystyrene, with an increasing number of arms. The ellipsoidal character of the star polystyrenes with fewer arms may originate from the extended anisotropically branched architecture at the center of the molecule. The arms of the star polystyrenes were found to be more extended than those of the linear polystyrenes. Furthermore, the degree of chain extension in the arms increased with the number of arms.

  3. Unequal-Arms Michelson Interferometers

    Science.gov (United States)

    Tinto, Massimo; Armstrong, J. W.

    2000-01-01

    Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

  4. Armed conflict and child health

    OpenAIRE

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health\\ud throughout the world. One in six children worldwide lives\\ud in an area of armed conflict and civilians are more likely\\ud to die than soldiers as a result of the conflict. In stark\\ud contrast to the effect on children, the international arms\\ud trade results in huge profits for the large corporations\\ud involved in producing arms, weapons and munitions.\\ud Armed conflict is not inevitable but is an important\\ud health issue that should be...

  5. Effects of age, sex and arm on the precision of arm position sense—left-arm superiority in healthy right-handers

    OpenAIRE

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally th...

  6. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  7. Design of a multi-arm randomized clinical trial with no control arm.

    Science.gov (United States)

    Magaret, Amalia; Angus, Derek C; Adhikari, Neill K J; Banura, Patrick; Kissoon, Niranjan; Lawler, James V; Jacob, Shevin T

    2016-01-01

    Clinical trial designs that include multiple treatments are currently limited to those that perform pairwise comparisons of each investigational treatment to a single control. However, there are settings, such as the recent Ebola outbreak, in which no treatment has been demonstrated to be effective; and therefore, no standard of care exists which would serve as an appropriate control. For illustrative purposes, we focused on the care of patients presenting in austere settings with critically ill 'sepsis-like' syndromes. Our approach involves a novel algorithm for comparing mortality among arms without requiring a single fixed control. The algorithm allows poorly-performing arms to be dropped during interim analyses. Consequently, the study may be completed earlier than planned. We used simulation to determine operating characteristics for the trial and to estimate the required sample size. We present a potential study design targeting a minimal effect size of a 23% relative reduction in mortality between any pair of arms. Using estimated power and spurious significance rates from the simulated scenarios, we show that such a trial would require 2550 participants. Over a range of scenarios, our study has 80 to 99% power to select the optimal treatment. Using a fixed control design, if the control arm is least efficacious, 640 subjects would be enrolled into the least efficacious arm, while our algorithm would enroll between 170 and 430. This simulation method can be easily extended to other settings or other binary outcomes. Early dropping of arms is efficient and ethical when conducting clinical trials with multiple arms. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Stereotactic ablative body radiotherapy for non-small-cell lung cancer: setup reproducibility with novel arms-down immobilization.

    Science.gov (United States)

    Moore, Karen; Paterson, Claire; Hicks, Jonathan; Harrow, Stephen; McJury, Mark

    2016-12-01

    A clinical evaluation of the intrafraction and interfraction setup accuracy of a novel thermoplastic mould immobilization device and patient position in early-stage lung cancer being treated with stereotactic radiotherapy at the Beatson West of Scotland Cancer Centre, Glasgow, UK. 35 patients were immobilized in a novel, arms-down position, with a four-point Klarity ™ (Klarity Medical Products, Ohio, US) clear thermoplastic mould fixed to a SinMed (CIVCO Medical solutions, lowa, US) head and neck board. A knee support was also used for patient comfort and support. Pre- and post-treatment kilovoltage cone beam CT (CBCT) images were fused with the planning CT scan to determine intra- and interfraction motion. A total of 175 CBCT scans were analysed in the longitudinal, vertical and lateral directions. The mean intrafraction errors were 0.05 ± 0.77 mm (lateral), 0.44 ± 1.2 mm (superior-inferior) and -1.44 ± 1.35 mm (anteroposterior), respectively. Mean composite three-dimensional displacement vector was 2.14 ± 1.2 mm. Interfraction errors were -0.66 ± 2.35 mm (lateral), -0.13 ± 3.11 mm (superior-inferior) and 0.00 ± 2.94 mm (anteroposterior), with three-dimensional vector 4.08 ± 2.73 mm. Setup accuracy for lung image-guided stereotactic ablative radiotherapy using a unique immobilization device, where patients have arms by their sides, has been shown to be safe and favourably comparable to other published setup data where more complex and cumbersome devices were utilised. There was no arm toxicity reported and low arm doses. Advances in knowledge: We report on the accuracy of a novel patient immobilization device.

  9. Evolution of Gas Across Spiral Arms in the Whirlpool Galaxy

    Science.gov (United States)

    Louie, Melissa Nicole

    To investigate the dynamic evolution of gas across spiral arms, we conducted a detailed study of the gas and star formation along the spiral arms in the Whirlpool Galaxy, M51. This nearby, face-on spiral galaxy provides a unique laboratory to study the relationship between gas dynamics and star formation. The textbook picture of interstellar medium (ISM) evolution is rapidly changing. Molecular gas was once believed to form along spiral arms from the diffuse atomic gas in the inter-arm regions. Star formation occurs within giant molecular clouds during spiral arm passage. Lastly, the molecular gas is photo-dissociated back into atomic gas by massive stars on the downstream side of the spiral arm. Recent evidence, however, is revealing a new picture of the interstellar medium and the process of star formation. We seek development of a new picture by studying the development and evolution of molecular gas and the role of large scale galactic dynamics in organizing the interstellar medium. This thesis begins by presenting work measuring the geometrical offsets between interstellar gas and recent star formation. Interstellar gas is traced by atomic hydrogen and carbon monoxide (CO). Star formation is traced by ionized hydrogen recombination lines and infrared emission from dust warmed by young bright stars. Measuring these offsets can help determine the underlying large scale galactic dynamics. Along the spiral arms in M51, offsets between CO and the star formation tracers suggest that gas is flowing through the spiral arms, but the offsets do not show the expected signature of a single pattern speed and imply a more complicated pattern. This thesis also examines the intermediate stages of gas evolution, by studying a denser component of the ISM closer to which stars will form. Only a small percent of the bulk molecular gas will become dense enough to form stars. HCN and HCO+ probe densities ˜104 cm-3, where as the bulk gas is 500 cm-3. This thesis looks at HCN and

  10. A study of mid-arm and chest circumferences as predictors of low birthweight.

    Science.gov (United States)

    Rogo, K; Nyagudi, O; Ferguson, A

    1991-02-01

    Nine hundred ninety-nine newborns were examined in order to determine the relationship between birthweight and mid-arm and chest circumstances. An early neonatal mortality rate of 51/1000 was recorded, being much higher for preterm (301/1000) than term babies (2.5/1000). Both mid-arm and chest circumference showed highly significant correlations with birthweight (r = 0.872, P less than 0.0001 and r = 0.918, P less than 0.0001, respectively). The correlation between weight and chest circumstances was upheld even for very small babies.

  11. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  12. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available   Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  13. Multifunctional Battalion Task Force Training: Slovenian Armed Forces Battalion Training Cycle

    Science.gov (United States)

    2016-06-10

    Capable of protecting vehicle mounted personnel against kinetic threats up non-AP small arms / 155 mm artillery bursts at 100 m and under belly hand...oyttmcbreen2001.pdf. Rock , Aaron J., Lance Corporal. “One step away from deployment, 26thu mewwraps up computex.” 26th Marine Expeditionary Unit, November

  14. Effects of age, sex and arm on the precision of arm position sense-left-arm superiority in healthy right-handers.

    Science.gov (United States)

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally the position of their unseen arm on a 0-90° circuit by comparing the current position with the target position indicated by a LED lamp, while the arm was passively moved by the examiner. Eighty-seven healthy subjects participated in the study, ranging from 20 to 77 years, subdivided into three age groups. The results revealed that APS was not a function of age or sex, but was significantly better in the non-dominant (left) arm in absolute errors (AE) but not in constant errors (CE) across all age groups of right-handed healthy subjects. This indicates a right-hemisphere superiority for left APS in right-handers and neatly fits to the more frequent and more severe left-sided body-related deficits in patients with unilateral stroke (i.e. impaired APS in left spatial neglect, somatoparaphrenia) or in individuals with abnormalities of the right cerebral hemisphere. These clinical issues will be discussed.

  15. Arms control and disarmament

    International Nuclear Information System (INIS)

    Acton, P.

    1992-01-01

    Article VI of the Non-Proliferation Treaty commits each party to work towards nuclear disarmament and to negotiations to stop the nuclear arms race. All parties to the Treaty are included and a wide range of arms control and disarmament issues are covered. However the main focus at Treaty review conferences has been on nuclear disarmament by the nuclear weapon states which are party to the Treaty. This has led to bilateral United States - Soviet Union negotiations resulting in the Intermediate-range Nuclear Forces Treaty in December 1987 and the Strategic Arms Reduction Treaty (START) in July followed by unilateral arms control measures in September and October 1991. (UK)

  16. Dynamic model of the octopus arm. I. Biomechanics of the octopus reaching movement.

    Science.gov (United States)

    Yekutieli, Yoram; Sagiv-Zohar, Roni; Aharonov, Ranit; Engel, Yaakov; Hochner, Binyamin; Flash, Tamar

    2005-08-01

    The octopus arm requires special motor control schemes because it consists almost entirely of muscles and lacks a rigid skeletal support. Here we present a 2D dynamic model of the octopus arm to explore possible strategies of movement control in this muscular hydrostat. The arm is modeled as a multisegment structure, each segment containing longitudinal and transverse muscles and maintaining a constant volume, a prominent feature of muscular hydrostats. The input to the model is the degree of activation of each of its muscles. The model includes the external forces of gravity, buoyancy, and water drag forces (experimentally estimated here). It also includes the internal forces generated by the arm muscles and the forces responsible for maintaining a constant volume. Using this dynamic model to investigate the octopus reaching movement and to explore the mechanisms of bend propagation that characterize this movement, we found the following. 1) A simple command producing a wave of muscle activation moving at a constant velocity is sufficient to replicate the natural reaching movements with similar kinematic features. 2) The biomechanical mechanism that produces the reaching movement is a stiffening wave of muscle contraction that pushes a bend forward along the arm. 3) The perpendicular drag coefficient for an octopus arm is nearly 50 times larger than the tangential drag coefficient. During a reaching movement, only a small portion of the arm is oriented perpendicular to the direction of movement, thus minimizing the drag force.

  17. Localization of small arms fire using acoustic measurements of muzzle blast and/or ballistic shock wave arrivals.

    Science.gov (United States)

    Lo, Kam W; Ferguson, Brian G

    2012-11-01

    The accurate localization of small arms fire using fixed acoustic sensors is considered. First, the conventional wavefront-curvature passive ranging method, which requires only differential time-of-arrival (DTOA) measurements of the muzzle blast wave to estimate the source position, is modified to account for sensor positions that are not strictly collinear (bowed array). Second, an existing single-sensor-node ballistic model-based localization method, which requires both DTOA and differential angle-of-arrival (DAOA) measurements of the muzzle blast wave and ballistic shock wave, is improved by replacing the basic external ballistics model (which describes the bullet's deceleration along its trajectory) with a more rigorous model and replacing the look-up table ranging procedure with a nonlinear (or polynomial) equation-based ranging procedure. Third, a new multiple-sensor-node ballistic model-based localization method, which requires only DTOA measurements of the ballistic shock wave to localize the point of fire, is formulated. The first method is applicable to situations when only the muzzle blast wave is received, whereas the third method applies when only the ballistic shock wave is received. The effectiveness of each of these methods is verified using an extensive set of real data recorded during a 7 day field experiment.

  18. Understanding the conventional arms trade

    Science.gov (United States)

    Stohl, Rachel

    2017-11-01

    The global conventional arms trade is worth tens of billions of dollars every year and is engaged in by every country in the world. Yet, it is often difficult to control the legal trade in conventional arms and there is a thriving illicit market, willing to arm unscrupulous regimes and nefarious non-state actors. This chapter examines the international conventional arms trade, the range of tools that have been used to control it, and challenges to these international regimes.

  19. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  20. Borehole tool outrigger arm displacement control mechanism

    International Nuclear Information System (INIS)

    Lee, A.G.

    1985-01-01

    As the outrigger arms of a borehole logging tool are flexed inwardly and outwardly according to the diameter of the borehole opening through which they pass, the corresponding axial displacements of the ends of the arms are controlled to determine the axial positions of the arms relative to the tool. Specifically, as the arm ends move, they are caused to rotate by a cam mechanism. The stiffness of the arms causes the arm ends to rotate in unison, and the exact positions of the arms on the tool are then controlled by the differential movements of the arm ends in the cams

  1. Proton tagging with the one arm AFP detector

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    The ATLAS Forward Proton (AFP) detector is designed to identify events in which one or two protons emerge intact from the LHC collisions at small angles. Such processes are usually associated with diffractive scattering. The first arm of the detector, consisting of tracking planes of 3D silicon sensors, was installed in February 2016. This note presents detector level distributions of events with a tagged proton with the AFP tracker and jets in the central detector in the final state.

  2. Transformation of armed violence: specific features and trends

    Directory of Open Access Journals (Sweden)

    O. B. Balatska

    2016-08-01

    Full Text Available Social transformations occurring in the world today became a result of globalization, information, changes in the international balance of power, and are reflected in all aspects of political development. One of the most pressing challenges of our time, a consequence of these processes, is the evolution of forms and methods of armed violence. This publication is devoted to determining the specific and major trends transforming the forms and methods of armed violence. Instead of the traditional military conflicts, new forms and means of armed confrontation emerge. Asymmetrical conflicts taking place with the participation of non-state parties and irregular armed groups, are quite common at the moment. «Hard power» methods associated with the use of direct violence are supplemented by means of «soft power». Violent but non-traditional (non-military means of confrontation widen, with informational and psychological influence becoming particularly prominent. Infotechnological and infopsychological methods of intervention have become an integral part of modern military-political confrontation, taking form of hybrid, network and network-centric warfare. The hybrid military conflicts are typically distinguished by asymmetry, latency, priority of small-scale combat actions and dynamic use of indirect violence. Network-centric warfare focused on achieving information superiority over the enemy, complex effects on the enemy’s physical, informational and cognitive domains, strategic flexibility and adaptability, priority of horizontal ties over traditional vertical hierarchy. Horizontal network infrastructure, consisting of multiple independent, highly specialized and geographically dispersed units, determines the effectiveness of network war strategy today. Apart from qualitative changes associated with emergence and proliferation of new forms of armed violence on a global scale, there is a definite global increase in its quantitative

  3. Nature of galaxy spiral arms

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1984-01-01

    The nature of galaxy spiral arms is discussed in a popular form. Two approaches in the theory of spiral arms are considered; they are related to the problem of differential galaxy rotation and the spiral structure wave theory. The example of Galaxy M31 is considered to compare the structural peculiarity of its spiral arms with the wave theory predictions. The situation in the central and south-eastern part of arm S4 in Galaxy M31 noted to be completely explained by the wave theory and modern concepts on the origin of massive stars

  4. Arms races between and within species.

    Science.gov (United States)

    Dawkins, R; Krebs, J R

    1979-09-21

    An adaptation in one lineage (e.g. predators) may change the selection pressure on another lineage (e.g. prey), giving rise to a counter-adaptation. If this occurs reciprocally, an unstable runaway escalation or 'arms race' may result. We discuss various factors which might give one side an advantage in an arms race. For example, a lineage under strong selection may out-evolve a weakly selected one (' the life-dinner principle'). We then classify arms races in two independent ways. They may be symmetric or asymmetric, and they may be interspecific or intraspecific. Our example of an asymmetric interspecific arms race is that between brood parasites and their hosts. The arms race concept may help to reduce the mystery of why cuckoo hosts are so good at detecting cuckoo eggs, but so bad at detecting cuckoo nestlings. The evolutionary contest between queen and worker ants over relative parental investment is a good example of an intraspecific asymmetric arms race. Such cases raise special problems because the participants share the same gene pool. Interspecific symmetric arms races are unlikely to be important, because competitors tend to diverge rather than escalate competitive adaptations. Intraspecific symmetric arms races, exemplified by adaptations for male-male competition, may underlie Cope's Rule and even the extinction of lineages. Finally we consider ways in which arms races can end. One lineage may drive the other to extinction; one may reach an optimum, thereby preventing the other from doing so; a particularly interesting possibility, exemplified by flower-bee coevolution, is that both sides may reach a mutual local optimum; lastly, arms races may have no stable and but may cycle continuously. We do not wish necessarily to suggest that all, or even most, evolutionary change results from arms races, but we do suggest that the arms race concept may help to resolve three long-standing questions in evolutionary theory.

  5. JPRS Report Arms Control

    National Research Council Canada - National Science Library

    1993-01-01

    Table of Contents: (1) COMMONWEALTH OF INDEPENDENT STATES - (A) GENERAL Flaws in U.S.-Russian SSD Agreement Viewed, Khariton - Espionage Not Crucial in Soviet Nuclear Arms Development, Further on Espionage Role in Nuclear Arms Projects...

  6. Organization of octopus arm movements: a model system for studying the control of flexible arms.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Yarom, Y; Fiorito, G; Segev, I; Hochner, B

    1996-11-15

    Octopus arm movements provide an extreme example of controlled movements of a flexible arm with virtually unlimited degrees of freedom. This study aims to identify general principles in the organization of these movements. Video records of the movements of Octopus vulgaris performing the task of reaching toward a target were studied. The octopus extends its arm toward the target by a wave-like propagation of a bend that travels from the base of the arm toward the tip. Similar bend propagation is seen in other octopus arm movements, such as locomotion and searching. The kinematics (position and velocity) of the midpoint of the bend in three-dimensional space were extracted using the direct linear transformation algorithm. This showed that the bend tends to move within a single linear plane in a simple, slightly curved path connecting the center of the animal's body with the target location. Approximately 70% of the reaching movements demonstrated a stereotyped tangential velocity profile. An invariant profile was observed when movements were normalized for velocity and distance. Two arms, extended together in the same behavioral context, demonstrated identical velocity profiles. The stereotyped features of the movements were also observed in spontaneous arm extensions (not toward an external target). The simple and stereotypic appearance of the bend trajectory suggests that the position of the bend in space and time is the controlled variable. We propose that this strategy reduces the immense redundancy of the octopus arm movements and hence simplifies motor control.

  7. STRUCTURAL VARIATION OF MOLECULAR GAS IN THE SAGITTARIUS ARM AND INTERARM REGIONS

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Tsuyoshi; Hasegawa, Tetsuo; Sugimoto, Masahiro [Joint ALMA Office, Alonso de Cordova 3107, Vitacura, Santiago 763-0355 (Chile); Koda, Jin [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800 (United States); Handa, Toshihiro, E-mail: sawada.tsuyoshi@nao.ac.jp [Department of Physics, Faculty of Science, Kagoshima University, 1-21-35 Korimoto, Kagoshima 890-0065 (Japan)

    2012-06-20

    We have carried out survey observations toward the Galactic plane at l Almost-Equal-To 38 Degree-Sign in the {sup 12}CO and {sup 13}CO J = 1-0 lines using the Nobeyama Radio Observatory 45 m telescope. A wide area (0.{sup 0}8 Multiplication-Sign 0.{sup 0}8) was mapped with high spatial resolution (17''). The line of sight samples the gas in both the Sagittarius arm and the interarm regions. The present observations reveal how the structure and physical conditions vary across a spiral arm. We classify the molecular gas in the line of sight into two distinct components based on its appearance: the bright and compact B component and the fainter and diffuse (i.e., more extended) D component. The B component is predominantly seen at the spiral arm velocities, while the D component dominates at the interarm velocities and is also found at the spiral arm velocities. We introduce the brightness distribution function and the brightness distribution index (BDI, which indicates the dominance of the B component) in order to quantify the map's appearance. The radial velocities of BDI peaks coincide with those of high {sup 12}CO J = 3-2/{sup 12}CO J = 1-0 intensity ratio (i.e., warm gas) and H II regions, and tend to be offset from the line brightness peaks at lower velocities (i.e., presumably downstream side of the arm). Our observations reveal that the gas structure at small scales changes across a spiral arm: bright and spatially confined structures develop in a spiral arm, leading to star formation at the downstream side, while extended emission dominates in the interarm region.

  8. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  9. Algorithms for Unequal-Arm Michelson Interferometers

    Science.gov (United States)

    Giampieri, Giacomo; Hellings, Ronald W.; Tinto, Massimo; Bender, Peter L.; Faller, James E.

    1994-01-01

    A method of data acquisition and data analysis is described in which the performance of Michelson-type interferometers with unequal arms can be made nearly the same as interferometers with equal arms. The method requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam.

  10. ARMed SPHINCS : computing a 41KB signature in 16KB of RAM

    NARCIS (Netherlands)

    Hülsing, A.T.; Rijneveld, J.; Schwabe, P.

    2015-01-01

    This paper shows that it is feasible to implement the stateless hash-based signature scheme SPHINCS-256 on a "very small device" with memory even smaller than a signature and limited computing power. We demonstrate that it is possible to generate and verify the 41\\,KB signature on an ARM Cortex M3

  11. Octopus-inspired multi-arm robotic swimming.

    Science.gov (United States)

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  12. Anatomical study on The Arm Greater Yang Small Intestine Meridian Muscle in Human

    Directory of Open Access Journals (Sweden)

    Kyoung-Sik, Park

    2004-06-01

    Full Text Available This study was carried to identify the component of Small Intestine Meridian Muscle in human, dividing the regional muscle group into outer, middle, and inner layer. the inner part of body surface were opened widely to demonstrate muscles, nerve, blood vessels and the others, displaying the inner structure of Small Intestine Meridian Muscle. We obtained the results as follows; 1. Small Intestine Meridian Muscle is composed of the muscle, nerve and blood vessels. 2. In human anatomy, it is present the difference between a term of nerve or blood vessels which control the muscle of Meridian Muscle and those which pass near by Meridian Muscle. 3. The inner composition of meridian muscle in human arm is as follows ; 1 Muscle ; Abd. digiti minimi muscle(SI-2, 3, 4, pisometacarpal lig.(SI-4, ext. retinaculum. ext. carpi ulnaris m. tendon.(SI-5, 6, ulnar collateral lig.(SI-5, ext. digiti minimi m. tendon(SI-6, ext. carpi ulnaris(SI-7, triceps brachii(SI-9, teres major(SI-9, deltoid(SI-10, infraspinatus(SI-10, 11, trapezius(Sl-12, 13, 14, 15, supraspinatus(SI-12, 13, lesser rhomboid(SI-14, erector spinae(SI-14, 15, levator scapular(SI-15, sternocleidomastoid(SI-16, 17, splenius capitis(SI-16, semispinalis capitis(SI-16, digasuicus(SI-17, zygomaticus major(Il-18, masseter(SI-18, auriculoris anterior(SI-19 2 Nerve ; Dorsal branch of ulnar nerve(SI-1, 2, 3, 4, 5, 6, br. of mod. antebrachial cutaneous n.(SI-6, 7, br. of post. antebrachial cutaneous n.(SI-6,7, br. of radial n.(SI-7, ulnar n.(SI-8, br. of axillary n.(SI-9, radial n.(SI-9, subscapular n. br.(SI-9, cutaneous n. br. from C7, 8(SI-10, 14, suprascapular n.(SI-10, 11, 12, 13, intercostal n. br. from T2(SI-11, lat. supraclavicular n. br.(SI-12, intercostal n. br. from C8, T1(SI-12, accessory n. br.(SI-12, 13, 14, 15, 16, 17, intercostal n. br. from T1,2(SI-13, dorsal scapular n.(SI-14, 15, cutaneous n. br. from C6, C7(SI-15, transverse cervical n.(SI-16, lesser occipital n. & great auricular n. from

  13. Measurement of the energy spectra relative to neutrons produced at very small angle in $\\mathrm{\\sqrt{s} = 13 ~ TeV}$ proton-proton collisions using the LHCf Arm2 detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00533910

    In the last years, several ground-based experiments have measured flux and composition of ultra high energy cosmic rays - i.e. cosmic rays having energies above $10^{18} ~ eV$ - up to the GZK cutoff region. Nevertheless, these analyses suffer of large uncertainties due to the fact that they must rely on hadronic interaction models, that exhibit very different behavior in the forward region due to the lack of high energy calibration data. To provide measurements that can be useful to tune these models is exactly the main aim of the LHC-forward (LHCf) experiment. Thanks to two small sampling calorimeter, Arm1 and Arm2, installed at $\\pm 140 ~ m$ from LHC IP1, LHCf can detect neutral particles produced in the very forward region ($\\eta > 8.4$) by proton-proton and proton-ion high energy collisions (proton-proton interaction at $\\sqrt{s} = 14 ~ TeV$ is equivalent to the collision of a $10^{17} ~ eV$ proton with a proton at rest, hence it is possible to perform measurements at an energy close to the typical one of...

  14. Security and arms control

    International Nuclear Information System (INIS)

    Kolodziej, E.A.; Morgan, P.M.

    1989-01-01

    This book attempts to clarify and define selected current issues and problems related to security and arms control from an international perspective. The chapters are organized under the following headings. Conflict and the international system, Nuclear deterrence, Conventional warfare, Subconventional conflict, Arms control and crisis management

  15. Version of the galaxy spiral structure model with opposite-directed arms and inter-arm links

    Energy Technology Data Exchange (ETDEWEB)

    Dolidze, M V [AN Gruzinskoj SSR, Abastumani. Abastumanskaya Astrofizicheskaya Observatoriya

    1963-05-01

    An attempt is made to explain some peculiarities of the local spiral structure and large-scale distribution of HII regions in the Galaxy by coexistence of the trailing and leading arm systems of different power and development. The existence of opposite-directed arms and inter-arm links in the circular zone (5-15 kpc) is analysed from the point of view of different Galaxy models.

  16. Spiral-arm instability: giant clump formation via fragmentation of a galactic spiral arm

    Science.gov (United States)

    Inoue, Shigeki; Yoshida, Naoki

    2018-03-01

    Fragmentation of a spiral arm is thought to drive the formation of giant clumps in galaxies. Using linear perturbation analysis for self-gravitating spiral arms, we derive an instability parameter and define the conditions for clump formation. We extend our analysis to multicomponent systems that consist of gas and stars in an external potential. We then perform numerical simulations of isolated disc galaxies with isothermal gas, and compare the results with the prediction of our analytic model. Our model describes accurately the evolution of the spiral arms in our simulations, even when spiral arms dynamically interact with one another. We show that most of the giant clumps formed in the simulated disc galaxies satisfy the instability condition. The clump masses predicted by our model are in agreement with the simulation results, but the growth time-scale of unstable perturbations is overestimated by a factor of a few. We also apply our instability analysis to derive scaling relations of clump properties. The expected scaling relation between the clump size, velocity dispersion, and circular velocity is slightly different from that given by the Toomre instability analyses, but neither is inconsistent with currently available observations. We argue that the spiral-arm instability is a viable formation mechanism of giant clumps in gas-rich disc galaxies.

  17. Poly(glycolide multi-arm star polymers: Improved solubility via limited arm length

    Directory of Open Access Journals (Sweden)

    Florian K. Wolf

    2010-06-01

    Full Text Available Due to the low solubility of poly(glycolic acid (PGA, its use is generally limited to the synthesis of random copolyesters with other hydroxy acids, such as lactic acid, or to applications that permit direct processing from the polymer melt. Insolubility is generally observed for PGA when the degree of polymerization exceeds 20. Here we present a strategy that allows the preparation of PGA-based multi-arm structures which significantly exceed the molecular weight of processable oligomeric linear PGA (<1000 g/mol. This was achieved by the use of a multifunctional hyperbranched polyglycerol (PG macroinitiator and the tin(II-2-ethylhexanoate catalyzed ring-opening polymerization of glycolide in the melt. With this strategy it is possible to combine high molecular weight with good molecular weight control (up to 16,000 g/mol, PDI = 1.4–1.7, resulting in PGA multi-arm star block copolymers containing more than 90 wt % GA. The successful linkage of PGA arms and PG core via this core first/grafting from strategy was confirmed by detailed NMR and SEC characterization. Various PG/glycolide ratios were employed to vary the length of the PGA arms. Besides fluorinated solvents, the materials were soluble in DMF and DMSO up to an average arm length of 12 glycolic acid units. Reduction in the Tg and the melting temperature compared to the homopolymer PGA should lead to simplified processing conditions. The findings contribute to broadening the range of biomedical applications of PGA.

  18. Controlled synthesis of multi-arm star polyether-polycarbonate polyols based on propylene oxide and CO2.

    Science.gov (United States)

    Hilf, Jeannette; Schulze, Patricia; Seiwert, Jan; Frey, Holger

    2014-01-01

    Multi-arm star copolymers based on a hyperbranched poly(propylene oxide) polyether-polyol (hbPPO) as a core and poly(propylene carbonate) (PPC) arms are synthesized in two steps from propylene oxide (PO), a small amount of glycidol and CO2 . The PPC arms are prepared via carbon dioxide (CO2 )/PO copolymerization, using hbPPO as a multifunctional macroinitiator and the (R,R)-(salcy)CoOBzF5 catalyst. Star copolymers with 14 and 28 PPC arms, respectively, and controlled molecular weights in the range of 2700-8800 g mol(-1) are prepared (Mw /Mn = 1.23-1.61). Thermal analysis reveals lowered glass transition temperatures in the range of -8 to 10 °C for the PPC star polymers compared with linear PPC, which is due to the influence of the flexible polyether core. Successful conversion of the terminal hydroxyl groups with phenylisocyanate demonstrates the potential of the polycarbonate polyols for polyurethane synthesis. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Arm Volumetry Versus Upper Extremity Lymphedema Index: Validity of Upper Extremity Lymphedema Index for Body-Type Corrected Arm Volume Evaluation.

    Science.gov (United States)

    Yamamoto, Nana; Yamamoto, Takumi; Hayashi, Nobuko; Hayashi, Akitatsu; Iida, Takuya; Koshima, Isao

    2016-06-01

    Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume. Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, 25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups. Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P 0.5]. Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.

  20. Modernization of African Armed Forces

    DEFF Research Database (Denmark)

    Mandrup, Thomas

    2015-01-01

    Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa.......Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa....

  1. 21 CFR 890.3640 - Arm sling.

    Science.gov (United States)

    2010-04-01

    ... arm sling is a device intended for medical purposes to immobilize the arm, by means of a fabric band... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arm sling. 890.3640 Section 890.3640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  2. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  3. ARM assembly language with hardware experiments

    CERN Document Server

    Elahi, Ata

    2015-01-01

    This book provides a hands-on approach to learning ARM assembly language with the use of a TI microcontroller. The book starts with an introduction to computer architecture and then discusses number systems and digital logic. The text covers ARM Assembly Language, ARM Cortex Architecture and its components, and Hardware Experiments using TILM3S1968. Written for those interested in learning embedded programming using an ARM Microcontroller. ·         Introduces number systems and signal transmission methods   ·         Reviews logic gates, registers, multiplexers, decoders and memory   ·         Provides an overview and examples of ARM instruction set   ·         Uses using Keil development tools for writing and debugging ARM assembly language Programs   ·         Hardware experiments using a Mbed NXP LPC1768 microcontroller; including General Purpose Input/Output (GPIO) configuration, real time clock configuration, binary input to 7-segment display, creating ...

  4. PHENIX Muon Arms

    International Nuclear Information System (INIS)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En'yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F.; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D.; Sondheim, W.E.; Sorensen, S.; Staley, F.; Stankus, P.W.; Steffens, S.; Stein, E.M.; Stepanov, M.; Stokes, W.; Sugioka, M.; Sun, Z.; Taketani, A.; Taniguchi, E.; Tepe, J.D.; Thornton, G.W.; Tian, W.; Tojo, J.; Torii, H.; Towell, R.S.; Tradeski, J.; Vassent, M.; Velissaris, C.; Villatte, L.; Wan, Y.; Watanabe, Y.; Watkins, L.C.; Whitus, B.R.; Williams, C.; Willis, P.S.; Wong-Swanson, B.G.; Yang, Y.; Yoneyama, S.; Young, G.R.; Zhou, S.

    2003-01-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons (∼10 -3 ). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described

  5. PHENIX Muon Arms

    Energy Technology Data Exchange (ETDEWEB)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En' yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F. E-mail: readkf@ornl.gov; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D. [and others

    2003-03-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons ({approx}10{sup -3}). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described.

  6. Kootenay Lake Fertilization Experiment, Year 15 (North Arm) and Year 3 (South Arm) (2006) Report

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, E.U.; Sebastian, D.; Andrusak, G.F. [Fish and Wildlife Science and Allocation, Ministry of Environment, Province of British Columbia

    2009-07-01

    This report summarizes results from the fifteenth year (2006) of nutrient additions to the North Arm of Kootenay Lake and three years of nutrient additions to the South Arm. Experimental fertilization of the lake has been conducted using an adaptive management approach in an effort to restore lake productivity lost as a result of nutrient uptake in upstream reservoirs. The primary objective of the experiment is to restore kokanee (Oncorhynchus nerka) populations, which are the main food source for Gerrard rainbow trout (Oncorhynchus mykiss) and bull trout (Salvelinus confluentus). The quantity of agricultural grade liquid fertilizer (10-34-0, ammonium polyphosphate and 28-0-0, urea ammonium nitrate) added to the North Arm in 2006 was 44.7 tonnes of P and 248.4 tonnes of N. The total fertilizer load added to the South Arm was 257 tonnes of nitrogen; no P was added. Kootenay Lake has an area of 395 km{sup 2}, a maximum depth of 150 m, a mean depth of 94 m, and a water renewal time of approximately two years. Kootenay Lake is a monomictic lake, generally mixing from late fall to early spring and stratifying during the summer. Surface water temperatures generally exceed 20 C for only a few weeks in July. Results of oxygen profiles were similar to previous years with the lake being well oxygenated from the surface to the bottom depths at all stations. Similar to past years, Secchi disc measurements at all stations in 2006 indicate a typical seasonal pattern of decreasing depths associated with the spring phytoplankton bloom, followed by increasing depths as the bloom gradually decreases by the late summer and fall. Total phosphorus (TP) ranged from 2-7 {micro}g/L and tended to decrease as summer advanced. Over the sampling season dissolved inorganic nitrogen (DIN) concentrations decreased, with the decline corresponding to nitrate (the dominant component of DIN) being utilized by phytoplankton during summer stratification. Owing to the importance of epilimnetic nitrate

  7. Association between intramuscular fat in the arm following arm training and INSIG2

    DEFF Research Database (Denmark)

    Popadic Gacesa, J Z; Secher, N H; Momcilovic, M

    2014-01-01

    ) ; mean ± standard deviation) carried out a 12-week two-arm elbow extensor training (10 maximal extensions with 1 min recovery between bouts) five times per day, five times per week. For 17 volunteers, upper arm muscle and adipose tissue [subcutaneous (SCAT) and intramuscular (IMAT)] volumes were.......0 ± 0.9%; GC/CC: %IMAT 0.6 ± 0.5% (P > 0.05). However, in the year following the training, accumulation of upper arm IMAT was twice as large in participants homozygous for the G allele (GG: Δ%IMAT +2.5 ± 0.8%; GC/CC: Δ%IMAT +1.1 ± 0.7%; P 

  8. Stratification of risk to the surgical team in removal of small arms ammunition implanted in the craniofacial region: case report.

    Science.gov (United States)

    Forbes, Jonathan A; Laughlin, Ian; Newberry, Shane; Ryhn, Michael; Pasley, Jason; Newberry, Travis

    2016-09-01

    In cases of penetrating injury with implantation of small arms ammunition, it can often be difficult to tell the difference between simple ballistics and ballistics associated with unexploded ordnances (UXOs). In the operative environment, where highly flammable substances are often close to the surgical site, detonation of UXOs could have catastrophic consequences for both the patient and surgical team. There is a paucity of information in the literature regarding how to evaluate whether an implanted munition contains explosive material. This report describes a patient who presented during Operation Enduring Freedom with an implanted munition suspicious for a UXO and the subsequent workup organized by Explosive Ordnance Disposal (EOD) Company prior to surgical removal. Clinical risk factors for UXOs include assassination attempts and/or wartime settings. Specific radiological features suggestive of a UXO include projectile size greater than 7.62-mm caliber, alterations in density of the tip, as well as radiological evidence of a hollowed-out core. If an implanted UXO is suspected, risks to the surgical and anesthesia teams can be minimized by notifying the nearest military installation with EOD capabilities and following clinical practice guidelines set forth by the Joint Theater Trauma System.

  9. Design of a biomimetic robotic octopus arm.

    Science.gov (United States)

    Laschi, C; Mazzolai, B; Mattoli, V; Cianchetti, M; Dario, P

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  10. Design of a biomimetic robotic octopus arm

    Energy Technology Data Exchange (ETDEWEB)

    Laschi, C; Cianchetti, M [Advanced Robotics Technology and Systems Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy); Mazzolai, B; Dario, P [Italian Institute of Technology, Genova (Italy); Mattoli, V [Centre of Research in Microengineering Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy)], E-mail: cecilia.laschi@sssup.it

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  11. Design of a biomimetic robotic octopus arm

    International Nuclear Information System (INIS)

    Laschi, C; Cianchetti, M; Mazzolai, B; Dario, P; Mattoli, V

    2009-01-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups

  12. Arm-in-Arm Response Regulator Dimers Promote Intermolecular Signal Transduction

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Anna W.; Satyshur, Kenneth A.; Morales, Neydis Moreno; Forest, Katrina T. (UW)

    2016-02-01

    ABSTRACT

    Bacteriophytochrome photoreceptors (BphPs) and their cognate response regulators make up two-component signal transduction systems which direct bacteria to mount phenotypic responses to changes in environmental light quality. Most of these systems utilize single-domain response regulators to transduce signals through unknown pathways and mechanisms. Here we describe the photocycle and autophosphorylation kinetics of RtBphP1, a red light-regulated histidine kinase from the desert bacteriumRamlibacter tataouinensis. RtBphP1 undergoes red to far-red photoconversion with rapid thermal reversion to the dark state. RtBphP1 is autophosphorylated in the dark; this activity is inhibited under red light. The RtBphP1 cognate response regulator, theR. tataouinensisbacteriophytochrome response regulator (RtBRR), and a homolog, AtBRR fromAgrobacterium tumefaciens, crystallize unexpectedly as arm-in-arm dimers, reliant on a conserved hydrophobic motif, hFWAhL (where h is a hydrophobic M, V, L, or I residue). RtBRR and AtBRR dimerize distinctly from four structurally characterized phytochrome response regulators found in photosynthetic organisms and from all other receiver domain homodimers in the Protein Data Bank. A unique cacodylate-zinc-histidine tag metal organic framework yielded single-wavelength anomalous diffraction phases and may be of general interest. Examination of the effect of the BRR stoichiometry on signal transduction showed that phosphorylated RtBRR is accumulated more efficiently than the engineered monomeric RtBRR (RtBRRmon) in phosphotransfer reactions. Thus, we conclude that arm-in-arm dimers are a relevant signaling intermediate in this class of two-component regulatory systems.

  13. How does a planet excite multiple spiral arms?

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-01-01

    Protoplanetary disk simulations show that a single planet excites multiple spiral arms in the background disk, potentially supported by the multi-armed spirals revealed with recent high-resolution observations in some disks. The existence of multiple spiral arms is of importance in many aspects. It is empirically found that the arm-to-arm separation increases as a function of the planetary mass, so one can use the morphology of observed spiral arms to infer the mass of unseen planets. In addition, a spiral arm opens a radial gap as it steepens into a shock, so when a planet excites multiple spiral arms it can open multiple gaps in the disk. Despite the important implications, however, the formation mechanism of multiple spiral arms has not been fully understood by far.In this talk, we explain how a planet excites multiple spiral arms. The gravitational potential of a planet can be decomposed into a Fourier series, a sum of individual azimuthal modes having different azimuthal wavenumbers. Using a linear wave theory, we first demonstrate that appropriate sets of Fourier decomposed waves can be in phase, raising a possibility that constructive interference among the waves can produce coherent structures - spiral arms. More than one spiral arm can form since such constructive interference can occur at different positions in the disk for different sets of waves. We then verify this hypothesis using a suite of two-dimensional hydrodynamic simulations. Finally, we present non-linear behavior in the formation of multiple spiral arms.

  14. Managing new arms races

    International Nuclear Information System (INIS)

    Segal, G.

    1992-01-01

    The management of new arms races in the region of Asia-Pacific includes considerations of weapons trade and transfer in the region, with an emphasis on nuclear weapons proliferation. It deals with the problem of controlling the arms trade and the efforts to control conventional weapons and underlines the possible role and influence of Conference on Cooperation and Security in Europe (CSCE)

  15. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  16. LES ARM Symbiotic Simulation and Observation (LASSO) Implementation Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Gustafson Jr., WI [Pacific Northwest National Laboratory; Vogelmann, AM [Brookhaven National Laboratory

    2015-09-01

    This document illustrates the design of the Large-Eddy Simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) workflow to provide a routine, high-resolution modeling capability to augment the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s high-density observations. LASSO will create a powerful new capability for furthering ARM’s mission to advance understanding of cloud, radiation, aerosol, and land-surface processes. The combined observational and modeling elements will enable a new level of scientific inquiry by connecting processes and context to observations and providing needed statistics for details that cannot be measured. The result will be improved process understanding that facilitates concomitant improvements in climate model parameterizations. The initial LASSO implementation will be for ARM’s Southern Great Plains site in Oklahoma and will focus on shallow convection, which is poorly simulated by climate models due in part to clouds’ typically small spatial scale compared to model grid spacing, and because the convection involves complicated interactions of microphysical and boundary layer processes.

  17. CHARACTERISTICS OF SPIRAL ARMS IN LATE-TYPE GALAXIES

    International Nuclear Information System (INIS)

    Honig, Z. N.; Reid, M. J.

    2015-01-01

    We have measured the positions of large numbers of H II regions in four nearly face-on, late-type, spiral galaxies: NGC 628 (M74), NGC 1232, NGC 3184, and NGC 5194 (M51). Fitting log-periodic spiral models to segments of each arm yields local estimates of spiral pitch angle and arm width. While pitch angles vary considerably along individual arms, among arms within a galaxy, and among galaxies, we find no systematic trend with galactocentric distance. We estimate the widths of the arm segments from the scatter in the distances of the H II regions from the spiral model. All major arms in these galaxies show spiral arm width increasing with distance from the galactic center, similar to the trend seen in the Milky Way. However, in the outermost parts of the galaxies, where massive star formation declines, some arms reverse this trend and narrow. We find that spiral arms often appear to be composed of segments of ∼5 kpc length, which join to form kinks and abrupt changes in pitch angle and arm width; these characteristics are consistent with properties seen in the large N-body simulations of D'Onghia et al. and others

  18. Training the Unimpaired Arm Improves the Motion of the Impaired Arm and the Sitting Balance in Chronic Stroke Survivors.

    Science.gov (United States)

    De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura

    2017-07-01

    Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.

  19. Picking Robot Arm Trajectory Planning Method

    Directory of Open Access Journals (Sweden)

    Zhang Zhiyong

    2014-01-01

    Full Text Available The picking robot arm is scheduled to complete picking tasks in the working space, to overcome the shaking vibration to improve the picking stability, its movement should follow specific consistence trajectory points. Usually we should give definite multiple feature picking points, map their inverse kinematics to the joint space, establish motion equation for the corresponding point in the joint space, then follow these equations motion for the interpolation on the joint so that we can meet the movement requirements. Trajectory planning is decisive significance for accuracy and stability of controlling robot arm. The key issue that picking arm complete picking task will be come true by trajectory planning, namely, robot arm track the desired trajectory. which based on kinematics and statics picking analysis in a joint space according to the requirements of picking tasks, and obtain the position and orientation for picking robot arm, study and calculate the theory of trajectory parameters timely.

  20. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  1. Supporting the President's Arms Control and Nonproliferation Agenda: Transparency and Verification for Nuclear Arms Reductions

    International Nuclear Information System (INIS)

    Doyle, James E.; Meek, Elizabeth

    2009-01-01

    The President's arms control and nonproliferation agenda is still evolving and the details of initiatives supporting it remain undefined. This means that DOE, NNSA, NA-20, NA-24 and the national laboratories can help define the agenda, and the policies and the initiatives to support it. This will require effective internal and interagency coordination. The arms control and nonproliferation agenda is broad and includes the path-breaking goal of creating conditions for the elimination of nuclear weapons. Responsibility for various elements of the agenda will be widely scattered across the interagency. Therefore an interagency mapping exercise should be performed to identify the key points of engagement within NNSA and other agencies for creating effective policy coordination mechanisms. These can include informal networks, working groups, coordinating committees, interagency task forces, etc. It will be important for NA-20 and NA-24 to get a seat at the table and a functional role in many of these coordinating bodies. The arms control and nonproliferation agenda comprises both mature and developing policy initiatives. The more mature elements such as CTBT ratification and a follow-on strategic nuclear arms treaty with Russia have defined milestones. However, recent press reports indicate that even the START follow-on strategic arms pact that is planned to be complete by the end of 2009 may take significantly longer and be more expansive in scope. The Russians called for proposals to count non-deployed as well as deployed warheads. Other elements of the agenda such as FMCT, future bilateral nuclear arms reductions following a START follow-on treaty, nuclear posture changes, preparations for an international nuclear security summit, strengthened international safeguards and multilateral verification are in much earlier stages of development. For this reason any survey of arms control capabilities within the USG should be structured to address potential needs across the

  2. Simulation of Octopus Arm Based on Coupled CPGs

    Directory of Open Access Journals (Sweden)

    Juan Tian

    2015-01-01

    Full Text Available The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs are built and a 2-dimensional dynamic model of the octopus arm is presented to explore possible strategies of the octopus movement control. And the CPGs’ signals treated as activation are added on the ventral, dorsal, and transversal sides, respectively. The effects of the octopus arm are discussed when the parameters of the CPGs are changed. Simulations show that the octopus arm movements are mainly determined by the shapes of three CPGs’ phase diagrams. Therefore, some locomotion modes are supposed to be embedded in the neuromuscular system of the octopus arm. And the octopus arm movements can be achieved by modulating the parameters of the CPGs. The results are beneficial for researchers to understand the octopus movement further.

  3. Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography

    DEFF Research Database (Denmark)

    Claudius, C; Skovgaard, L T; Viby-Mogensen, J

    2010-01-01

    Studies comparing acceleromyography and mechanomyography indicate that the two methods cannot be used interchangeably. However, it is uncertain to what extent differences in precision between the methods and the naturally occurring arm-to-arm variation have influenced the results of these studies...

  4. Broken Arm

    Science.gov (United States)

    ... of falling — including football, soccer, gymnastics, skiing and skateboarding — also increases the risk of a broken arm. ... for high-risk activities, such as in-line skating, snowboarding, rugby and football. Don't smoke. Smoking ...

  5. 49 CFR 236.810 - Spectacle, semaphore arm.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Spectacle, semaphore arm. 236.810 Section 236.810 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Spectacle, semaphore arm. That part of a semaphore arm which holds the roundels and to which the blade is...

  6. Arming shoes of the fifteenth century

    OpenAIRE

    Volken Marquita

    2017-01-01

    Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming sh...

  7. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  8. International security and arms control

    International Nuclear Information System (INIS)

    Ekeus, R.

    2000-01-01

    The end of the cold war also ended the focus on the bilateral approach to arms control and disarmament. Key concepts of security needed to be revisited, along with their implications for the disarmament and arms control agenda. Though there is currently a unipolar global security environment, there remain important tasks on the multilateral arms control agenda. The major task is that of reducing and eliminating weapons of mass destruction, especially nuclear weapons. The author contends that maintaining reliance on the nuclear-weapons option makes little sense in a time when the major Powers are strengthening their partnerships in economics, trade, peacemaking and building. (author)

  9. Preventing Interstate Armed Conflict : whose responsibility?

    OpenAIRE

    Otunba, Ganiyu

    2010-01-01

    This is a study of interstate armed conflict prevention. The concept of conflict, armed conflict and conflict prevention is defined and explained in order to be able to investigate if there is any single institution saddled with the responsibility of preventing interstate armed conflict and also to verify if adequate efforts are been put in this area which is of importance to mankind. The relationship between conflict prevention, conflict management and conflict resolution is also discussed s...

  10. Strategic arms limitation

    Science.gov (United States)

    Allen Greb, G.; Johnson, Gerald W.

    1983-10-01

    Following World War II, American scientists and politicians proposed in the Baruch plan a radical solution to the problem of nuclear weapons: to eliminate them forever under the auspices of an international nuclear development authority. The Soviets, who as yet did not possess the bomb, rejected this plan. Another approach suggested by Secretary of War Henry Stimson to negotiate directly with the Soviet Union was not accepted by the American leadership. These initial arms limitation failures both reflected and exacerbated the hostile political relationship of the superpowers in the 1950s and 1960s. Since 1969, the more modest focus of the Soviet-American arms control process has been on limiting the numbers and sizes of both defensive and offensive strategic systems. The format for this effort has been the Strategic Arms Limitatins Talks (Salt) and more recently the Strategic Arms Reduction Talks (START). Both sides came to these negotiations convinced that nuclear arsenals had grown so large that some for of mutual restraint was needed. Although the SALT/START process has been slow and ponderous, it has produced several concrete the agreements and collateral benefits. The 1972 ABM Treaty restricts the deployment of ballistic missile defense systems, the 1972 Interim Agreement places a quantitative freeze on each side's land based and sea based strategic launchers, and the as yet unratified 1979 SALT II Treaty sets numerical limits on all offensive strategic systems and sublimits on MIRVed systems. Collateral benefits include improved verification procedures, working definitions and counting rules, and permanent bureaucratic apparatus which enhance stability and increase the chances for achieving additional agreements.

  11. Planet-driven Spiral Arms in Protoplanetary Disks. II. Implications

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    We examine whether various characteristics of planet-driven spiral arms can be used to constrain the masses of unseen planets and their positions within their disks. By carrying out two-dimensional hydrodynamic simulations varying planet mass and disk gas temperature, we find that a larger number of spiral arms form with a smaller planet mass and a lower disk temperature. A planet excites two or more spiral arms interior to its orbit for a range of disk temperatures characterized by the disk aspect ratio 0.04≤slant {(h/r)}p≤slant 0.15, whereas exterior to a planet’s orbit multiple spiral arms can form only in cold disks with {(h/r)}p≲ 0.06. Constraining the planet mass with the pitch angle of spiral arms requires accurate disk temperature measurements that might be challenging even with ALMA. However, the property that the pitch angle of planet-driven spiral arms decreases away from the planet can be a powerful diagnostic to determine whether the planet is located interior or exterior to the observed spirals. The arm-to-arm separations increase as a function of planet mass, consistent with previous studies; however, the exact slope depends on disk temperature as well as the radial location where the arm-to-arm separations are measured. We apply these diagnostics to the spiral arms seen in MWC 758 and Elias 2–27. As shown in Bae et al., planet-driven spiral arms can create concentric rings and gaps, which can produce a more dominant observable signature than spiral arms under certain circumstances. We discuss the observability of planet-driven spiral arms versus rings and gaps.

  12. Multi-arm group sequential designs with a simultaneous stopping rule.

    Science.gov (United States)

    Urach, S; Posch, M

    2016-12-30

    Multi-arm group sequential clinical trials are efficient designs to compare multiple treatments to a control. They allow one to test for treatment effects already in interim analyses and can have a lower average sample number than fixed sample designs. Their operating characteristics depend on the stopping rule: We consider simultaneous stopping, where the whole trial is stopped as soon as for any of the arms the null hypothesis of no treatment effect can be rejected, and separate stopping, where only recruitment to arms for which a significant treatment effect could be demonstrated is stopped, but the other arms are continued. For both stopping rules, the family-wise error rate can be controlled by the closed testing procedure applied to group sequential tests of intersection and elementary hypotheses. The group sequential boundaries for the separate stopping rule also control the family-wise error rate if the simultaneous stopping rule is applied. However, we show that for the simultaneous stopping rule, one can apply improved, less conservative stopping boundaries for local tests of elementary hypotheses. We derive corresponding improved Pocock and O'Brien type boundaries as well as optimized boundaries to maximize the power or average sample number and investigate the operating characteristics and small sample properties of the resulting designs. To control the power to reject at least one null hypothesis, the simultaneous stopping rule requires a lower average sample number than the separate stopping rule. This comes at the cost of a lower power to reject all null hypotheses. Some of this loss in power can be regained by applying the improved stopping boundaries for the simultaneous stopping rule. The procedures are illustrated with clinical trials in systemic sclerosis and narcolepsy. © 2016 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. © 2016 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  13. Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Grattan, Mark W. D.; McGarry, Conor K.

    2010-01-01

    Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2±0.2, +1.8±1.6, and +7.4±0.5 mm for the R-arms, and +2.9±0.2, +2.1±0.8, and +4.9±0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1±0.4, -4.7±0.4, and -2.5

  14. Controlling robot arm with the mind

    National Science Foundation

    2017-05-31

    Full Text Available Research test subjects at the University of Minnesota who were fitted with a specialized noninvasive brain cap were able to move a robotic arm just by imagining moving their own arms.

  15. Small Arms of the Scythians. On the Time of Sigmoid Bow Appearance in Eastern Europe

    Directory of Open Access Journals (Sweden)

    Lukyashko Sergey Ivanovich

    2015-12-01

    Full Text Available Horse archers well-known in the ancient world used composite sigmoid bows for shooting (archery, the specific constructive features of which have been studied by the researchers. This type of a bow was convergently formed in Eastern China in the middle of the 2nd millennium B.C. and in the North Caucasus in the middle of the 4th millennium B.C. It gets transferred to the Northern Black Sea Region by the Scythians in the late 7th - early 6th centuries B.C. that resulted in the dramatic transformation of arrowheads’ types. The Greeks became aware of this weapon in the last third of the 6th century B.C. Bows can be divided into simple and complex ones. The simple bows are made from one solid bar, while the complex bows are made of several layers of different wood species. Composite bows are constructed from a few consequently connected bars. These types also include a reinforced bow – the bow springing qualities of which are reinforced by bone or tendon plates. Since the ancient masters combined different production methods, the definition of a composite reinforced bow can be found in the literature. European small arms development was focused on improving a simple bow. The strength of such bow was achieved by its size. However, massive bows are unsuitable for firing from a horse. Therefore, in cultures associated with the development of riding the search of methods of bow strength increase at the condition of reducing its size, was going on. In Asia, the focus was made on the material rather than shoulders design. As a result, complex composite bows appear in the East, which were made from several pieces of wood, connected with the central part of the handle at an angle. After the appearance of the Scythians in the middle East the angular design of bows was replaced by a sigmoid shape (scythicus acrus.

  16. Rolling motions in an inner spiral arm

    International Nuclear Information System (INIS)

    Strauss, F.M.; Poeppel, W.

    1976-01-01

    Hydrogen line observations made at low galactic latitudes for l=318degree, 326degree, 334degree, and 337degree show the presence of velocity gradients in latitude in the nearest inner spiral arm, similar to those found by other observations in different regions. Maximum velocity change is about 10 km s -1 for l=337degree. By generating synthetic line profiles constructed from a model spiral arm, several possible causes of these ''rolling motions'' were studied, such as a vertical displacement or a tilt of the arm (which failed to account for the observations) and rotation or shearing in the arm. It was futher shown that a typical arm can maintain such a motion (approx. =75 km s -1 kpc -1 ) with its own gravitational potential. The results are used to study the origin and tilt of Gould's Belt

  17. Arming shoes of the fifteenth century

    Directory of Open Access Journals (Sweden)

    Volken Marquita

    2017-12-01

    Full Text Available Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming shoes. The question of why medieval military footwear shows no purposed development is addressed.

  18. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  19. Two-Armed, Mobile, Sensate Research Robot

    Science.gov (United States)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and

  20. Simulation of Octopus Arm Based on Coupled CPGs

    OpenAIRE

    Juan Tian; Qiang Lu

    2015-01-01

    The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs) are built and a 2-dimens...

  1. Kinematic decomposition and classification of octopus arm movements

    OpenAIRE

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm move...

  2. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Science.gov (United States)

    Hu, Weitong; Li, Juxiang; Su, Hai; Wang, Jiwei; Xu, Jinsong; Liu, Yanna; Huang, Ming; Cheng, Xiaoshu

    2014-01-01

    To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives). Following baseline diameter (D0) and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD) was calculated as the percentage increase of artery diameter (ΔD/D0). The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r). At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, Parm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  3. Robust coordinated control of a dual-arm space robot

    Science.gov (United States)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  4. Bilateral movements increase sustained extensor force in the paretic arm.

    Science.gov (United States)

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  5. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  6. Nuclear Arms Race and Environment

    OpenAIRE

    Li, Anpeng

    2012-01-01

    This paper introduces a new factor, environment, into nuclear arms race model. In this model, nuclear weapons produce larger defense power compared with conventional arms, but hurt the environment meanwhile. In the global welfare maximum level, both conventional and nuclear weapons budget are zero. However, the competitive equilibrium may not achieve the optimum. I give the condition to jump out of the prisoner's dilemma.

  7. Evaluation of arm-leg coordination in flat breaststroke.

    Science.gov (United States)

    Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M

    2004-10-01

    This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.

  8. Ray tracing reconstruction investigation for C-arm tomosynthesis

    Science.gov (United States)

    Malalla, Nuhad A. Y.; Chen, Ying

    2016-04-01

    C-arm tomosynthesis is a three dimensional imaging technique. Both x-ray source and the detector are mounted on a C-arm wheeled structure to provide wide variety of movement around the object. In this paper, C-arm tomosynthesis was introduced to provide three dimensional information over a limited view angle (less than 180o) to reduce radiation exposure and examination time. Reconstruction algorithms based on ray tracing method such as ray tracing back projection (BP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were developed for C-arm tomosynthesis. C-arm tomosynthesis projection images of simulated spherical object were simulated with a virtual geometric configuration with a total view angle of 40 degrees. This study demonstrated the sharpness of in-plane reconstructed structure and effectiveness of removing out-of-plane blur for each reconstruction algorithms. Results showed the ability of ray tracing based reconstruction algorithms to provide three dimensional information with limited angle C-arm tomosynthesis.

  9. Defining and comparing learning actions in two simulation modalities: students training on a latex arm and each other's arms.

    Science.gov (United States)

    Ravik, Monika; Havnes, Anton; Bjørk, Ida Torunn

    2017-12-01

    To explore, describe and compare learning actions that nursing students used during peripheral vein cannulation training on a latex arm or each other's arms in a clinical skills centre. Simulation-based training is thought to enhance learning and transfer of learning from simulation to the clinical setting and is commonly recommended in nursing education. What students actually are doing during simulation-based training is, however, less explored. The analysis of learning actions used during simulation-based training could contribute to development and improvement of simulation as a learning strategy in nursing education. A qualitative explorative and descriptive research design, involving content analysis of video recordings, was used. Video-supported observation of nine nursing students practicing vein cannulation was conducted in a clinical skills centre in late 2012. The students engaged in various learning actions. Students training on a latex arm used a considerably higher number of learning actions relative to those training on each other's arms. In both groups, students' learning actions consisted mainly of seeking and giving support. The teacher provided students training on each other's arms with detailed feedback regarding insertion of the cannula into the vein, while those training on a latex arm received sparse feedback from the teacher and fellow students. The teacher played an important role in facilitating nursing students' practical skill learning during simulation. The provision of support from both teachers and students should be emphasised to ensure that nursing students' learning needs are met. This study suggest that student nurses may be differently and inadequately prepared in peripheral vein cannulation in two simulation modalities used in the academic setting; training on a latex arm and on each other's arms. © 2017 John Wiley & Sons Ltd.

  10. Kinematic decomposition and classification of octopus arm movements.

    Science.gov (United States)

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  11. Star distribution in the Orion spiral arm

    International Nuclear Information System (INIS)

    Basharina, T.S.; Pavlovskaya, E.D.; Filippova, A.A.

    1985-01-01

    The structure of the Orion spiral arm is studied by numerical experiments, assuming that in each direction considered the star distribution along the line of sight is a combination of two Gaussian laws. The corresponding parameters are evaluated for four Milky Way fields; the bimodal laws now fit the observations by the chi 2 criterion. In the Orion arm the line-of-sight star densities follow asymmetric curves, steeper at the outer edge of the arm

  12. Dynamic Model of a Rotating Flexible Arm-Flexible Root Mechanism Driven by a Shaft Flexible in Torsion

    Directory of Open Access Journals (Sweden)

    S.Z. Ismail

    2006-01-01

    Full Text Available This paper presents a dynamic model of a rotating flexible beam carrying a payload at its tip. The model accounts for the driving shaft and the arm root flexibilities. The finite element method and the Lagrangian dynamics are used in deriving the equations of motion with the small deformation theory assumptions and the Euler-Bernoulli beam theory. The obtained model is a nonlinear-coupled system of differential equations. The model is simulated for different combinations of shaft and root flexibilities and arm properties. The simulation results showed that the root flexibility is an important factor that should be considered in association with the arm and shaft flexibilities, as its dynamics influence the motor motion. Moreover, the effect of system non-linearity on the dynamic behavior is investigated by simulating the equivalent linearized system and it was found to be an important factor that should be considered, particularly when designing a control strategy for practical implementation.

  13. ARM Unmanned Aerial Systems Implementation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS for the science missions ARM supports.

  14. Passive detection of nuclear-armed SLCMs

    International Nuclear Information System (INIS)

    Sagdeev, R.Z.; Prilutsky, O.F.; Frolov, V.A.

    1992-01-01

    Effective procedures have been developed, using national technical measures (photoreconnaissance satellites, radiointercept stations, etc.), for verification of reductions in land-based intercontinental ballistic missiles, such as marine-based ballistic missiles, and strategic bombers. However, there is agreement on procedures for verifying limitations of numbers of long-range nuclear-armed cruise missiles. The difficulties in developing such procedures are sometimes regarded (by opponents of nuclear disarmament) as a reason why cruise missiles based on ships and submarines ought not to be limited by future arms-reduction treaties. This paper considers the detectability of nuclear-armed cruise missiles through the penetrating radiation emitted spontaneously from their warheads

  15. Control of octopus arm extension by a peripheral motor program.

    Science.gov (United States)

    Sumbre, G; Gutfreund, Y; Fiorito, G; Flash, T; Hochner, B

    2001-09-07

    For goal-directed arm movements, the nervous system generates a sequence of motor commands that bring the arm toward the target. Control of the octopus arm is especially complex because the arm can be moved in any direction, with a virtually infinite number of degrees of freedom. Here we show that arm extensions can be evoked mechanically or electrically in arms whose connection with the brain has been severed. These extensions show kinematic features that are almost identical to normal behavior, suggesting that the basic motor program for voluntary movement is embedded within the neural circuitry of the arm itself. Such peripheral motor programs represent considerable simplification in the motor control of this highly redundant appendage.

  16. Technology and the arms race

    International Nuclear Information System (INIS)

    MacKenzie, D.

    1988-01-01

    This article makes a review of the book Innovation and the Arms Race: How the United States and the Soviet Union Develop New Military Technologies written by Matthew Evangelista. For at least the last two decades, scholars have struggled to come to grips with the role of technological change in the arms race. Possible relationships between theories on technology and politics are examined. The contrasts between U.S. and Soviet approaches are highlighted

  17. Optimizing Armed Forces Capabilities for Hybrid Warfare – New Challenge for Slovak Armed Forces

    Directory of Open Access Journals (Sweden)

    Peter PINDJÁK

    2015-09-01

    Full Text Available The paper deals with the optimization of military capabilities of the Slovak Armed Forces for conducting operations in a hybrid conflict, which represents one of the possible scenarios of irregular warfare. Whereas in the regular warfare adversaries intend to eliminate the centers of gravity of each other, most often command and control structures, in irregular conflicts, the center of gravity shifts towards the will and cognitive perception of the target population. Hybrid warfare comprises a thoroughly planned combination of conventional military approaches and kinetic operations with subversive, irregular activities, including information and cyber operations. These efforts are often accompanied by intensified activities of intelligence services, special operation forces, and even mercenary and other paramilitary groups. The development of irregular warfare capabilities within the Slovak Armed Forces will require a progressive transformation process that may turn the armed forces into a modern and adaptable element of power, capable of deployment in national and international crisis management operations.

  18. A studentized permutation test for three-arm trials in the 'gold standard' design.

    Science.gov (United States)

    Mütze, Tobias; Konietschke, Frank; Munk, Axel; Friede, Tim

    2017-03-15

    The 'gold standard' design for three-arm trials refers to trials with an active control and a placebo control in addition to the experimental treatment group. This trial design is recommended when being ethically justifiable and it allows the simultaneous comparison of experimental treatment, active control, and placebo. Parametric testing methods have been studied plentifully over the past years. However, these methods often tend to be liberal or conservative when distributional assumptions are not met particularly with small sample sizes. In this article, we introduce a studentized permutation test for testing non-inferiority and superiority of the experimental treatment compared with the active control in three-arm trials in the 'gold standard' design. The performance of the studentized permutation test for finite sample sizes is assessed in a Monte Carlo simulation study under various parameter constellations. Emphasis is put on whether the studentized permutation test meets the target significance level. For comparison purposes, commonly used Wald-type tests, which do not make any distributional assumptions, are included in the simulation study. The simulation study shows that the presented studentized permutation test for assessing non-inferiority in three-arm trials in the 'gold standard' design outperforms its competitors, for instance the test based on a quasi-Poisson model, for count data. The methods discussed in this paper are implemented in the R package ThreeArmedTrials which is available on the comprehensive R archive network (CRAN). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Endoscopic management of intraoperative small bowel laceration during natural orifice translumenal endoscopic surgery: a blinded porcine study.

    Science.gov (United States)

    Fyock, Christopher J; Forsmark, Chris E; Wagh, Mihir S

    2011-01-01

    Natural orifice translumenal endoscopic surgery (NOTES) has recently gained great enthusiasm, but there is concern regarding the ability to endoscopically manage complications purely via natural orifices. To assess the feasibility of endoscopically managing enteral perforation during NOTES using currently available endoscopic accessories. Twelve pigs underwent transgastric or transcolonic endoscopic exploration. Full-thickness enterotomies were intentionally created to mimic accidental small bowel lacerations during NOTES. These lacerations were then closed with endoclips. In the blinded arm of the study, small bowel repair was performed by a second blinded endoscopist. Adequate closure of the laceration was confirmed with a leak test. Primary access sites were closed with endoclips or T-anchors. At necropsy, the peritoneal cavity was inspected for abscesses, bleeding, or damage to surrounding structures. The enterotomy site was examined for adequacy of closure, adhesions, or evidence of infection. Fifteen small bowel lacerations were performed in 12 animals. Successful closure was achieved in all 10 cases in the nonblinded arm. Survival animals had an uncomplicated postoperative course and all enterotomy sites were well healed without evidence of necrosis, adhesions, abscess, or bleeding at necropsy. Leak test was negative in all animals. In the blinded arm, both small intestinal lacerations could not be identified by the blinded endoscopist. Necropsy revealed open small bowel lacerations. Small intestinal injuries are difficult to localize with currently available flexible endoscopes and accessories. Endoscopic clips, however, may be adequate for closure of small bowel lacerations if the site of injury is known.

  20. Simple model of the arms race

    International Nuclear Information System (INIS)

    Zane, L.I.

    1982-01-01

    A simple model of a two-party arms race is developed based on the principle that the race will continue so long as either side can unleash an effective first strike against the other side. The model is used to examine how secrecy, the ABM, MIRV-ing, and an MX system affect the arms race

  1. Kinematic decomposition and classification of octopus arm movements

    Directory of Open Access Journals (Sweden)

    Ido eZelman

    2013-05-01

    Full Text Available The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  2. Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

    Science.gov (United States)

    Doshi, Hardik; Weder, Alan B; Bard, Robert L; Brook, Robert D

    2010-02-01

    Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, PBlood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

  3. Arms control, nonproliferation, and US national security

    International Nuclear Information System (INIS)

    Pilat, J.F.

    1985-01-01

    The continuation of the arms race and the failure of arms control and disarmament negotiations lend support to the belief that US and Soviet power, prestige, and security depend upon nuclear weapons. Therefore, the argument goes, the non-nuclear-weapon states (particularly those that are not allied with nuclear-weapon states and do not share their nuclear shield) may conclude that they would be well served by possession of these weapons. In this sense, the failure of nuclear arms reductions could create incentives for further proliferation

  4. Utility of C-arm CT in overcoming challenges in patients undergoing Transarterial chemoembolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kulkarni, Chinmay; Sreekumar, K. P.; Prabhu, Nirmal Kumar; Kannan, Rajesh R; Moorthy, Srikanth

    2014-01-01

    Transarterial chemoembolization (TACE) is the well-known treatment for hepatocellular carcinoma. Multiple digital subtraction angiography (DSA) acquisitions in different projections are required to identify difficult arterial feeders. Moreover, the tell-tale tumor blush can be obscured by proximity to lung base, small size of lesion, and breathing artifacts. C-arm CT is a revolutionary advancement in the intervention radiology suite that allows acquisition of data which can be reformatted in multiple planes and volume rendered incorporating both soft tissue and vascular information like multidetector computed tomography (MDCT). These images acquired during the TACE procedure can provide critical inputs for achieving a safe and effective therapy. This case series aims to illustrate the utility of C-arm CT in solving specific problems encountered while performing TACE

  5. Hybrid Kalman and unscented Kalman filters for INS/GPS integrated system considering constant lever arm effect

    Institute of Scientific and Technical Information of China (English)

    常国宾; 柳明

    2015-01-01

    In inertial navigation system (INS) and global positioning system (GPS) integrated system, GPS antennas are usually not located at the same location as the inertial measurement unit (IMU) of the INS, so the lever arm effect exists, which makes the observation equation highly nonlinear. The INS/GPS integration with constant lever arm effect is studied. The position relation of IMU and GPS’s antenna is represented in the earth centered earth fixed frame, while the velocity relation of these two systems is represented in local horizontal frame. Due to the small integration time interval of INS, i.e. 0.1 s in this work, the nonlinearity in the INS error equation is trivial, so the linear INS error model is constructed and addressed by Kalman filter’s prediction step. On the other hand, the high nonlinearity in the observation equation due to lever arm effect is addressed by unscented Kalman filter’s update step to attain higher accuracy and better applicability. Simulation is designed and the performance of the hybrid filter is validated.

  6. To Arm or Not to Arm: The Case Against Arming Vietnam and the Philippines

    Science.gov (United States)

    2015-04-13

    designed to allay 9 Leaf (accessed Oct 24, 2014). 10 Ankit Panda , “What to Expect if the U.S. Lifts...their animated populations. Despite the rhetoric, no ideology or nation is monolithic, thus opportunities exist to improve the U.S.-Sino...Joint Forces Quarterly 2 (2014): 76-80. Panda , Ankit. “What to Expect if the U.S. Lifts Its Vietnam Arms Embargo.” The Diplomat. September 29

  7. The Role of the Armed Forces in the Mexican Economy in the 1980’s.

    Science.gov (United States)

    1981-06-01

    integrating role, especially in 17 " . - _ .. .. .~- ... . .. . . . . . .. . ....._ • ,,.- .. . 1 .. .. •, , ," remote geographic regions, and have...integration of the Armed Forces insures their integration with the population in every town. This is especially important in the small villages. The...Jefe Edo Mayor de la Armada Revillagigedo No. 11 Primer Piso Mexico 1, D.F. 99 141. Vicealmirante Doroteo Silva Lopez Director de Educacion Naval Dr

  8. Stellar complexes in spiral arms of galaxies

    Science.gov (United States)

    Efremov, Yu. N.

    The history of the introduction and development of the star complexes conception is briefly described. These large groups of stars were picked out and named as such ones in our Galaxy with argumentation and evidence for their physical unity (using the Cepheid variables the distances and ages of which are easy determined from their periods); anyway earlier the complexes were noted along the spiral arms of the Andromeda galaxy, but were not recognized as a new kind of star group. The chains of complexes along the spiral arms are observed quite rarely; their origin is explained by magneto- gravitational or purely gravitational instability developing along the arm. It is not clear why these chains are quite a rare phenomenon - and more so why sometimes the regular chain of complexes are observed in one arm only. Probably intergalactic magnetic field participated in formation of such chains. Apart from the complexes located along the arms, there are isolated giant complexes known (up to 700 pc in diameter) which look like super-gigantic but rather rarefied globular clusters. Until now only two of these formations are studied, in NGC 6946 and M51.

  9. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Science.gov (United States)

    Font, Davinia; Pallejà, Tomàs; Tresanchez, Marcel; Runcan, David; Moreno, Javier; Martínez, Dani; Teixidó, Mercè; Palacín, Jordi

    2014-01-01

    This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions. PMID:24984059

  10. A Proposal for Automatic Fruit Harvesting by Combining a Low Cost Stereovision Camera and a Robotic Arm

    Directory of Open Access Journals (Sweden)

    Davinia Font

    2014-06-01

    Full Text Available This paper proposes the development of an automatic fruit harvesting system by combining a low cost stereovision camera and a robotic arm placed in the gripper tool. The stereovision camera is used to estimate the size, distance and position of the fruits whereas the robotic arm is used to mechanically pickup the fruits. The low cost stereovision system has been tested in laboratory conditions with a reference small object, an apple and a pear at 10 different intermediate distances from the camera. The average distance error was from 4% to 5%, and the average diameter error was up to 30% in the case of a small object and in a range from 2% to 6% in the case of a pear and an apple. The stereovision system has been attached to the gripper tool in order to obtain relative distance, orientation and size of the fruit. The harvesting stage requires the initial fruit location, the computation of the inverse kinematics of the robotic arm in order to place the gripper tool in front of the fruit, and a final pickup approach by iteratively adjusting the vertical and horizontal position of the gripper tool in a closed visual loop. The complete system has been tested in controlled laboratory conditions with uniform illumination applied to the fruits. As a future work, this system will be tested and improved in conventional outdoor farming conditions.

  11. Changing patterns of arms transfers

    International Nuclear Information System (INIS)

    Wulf, H.

    1998-01-01

    Three factors in the international system have been of importance for the trade of arms: the role of the main actors on the supply side and since 1970 on the demand side, the permanently increasing importance of economics, and the balance trade, industrial capacity and jobs in supplier countries and purchasing power of potential importers. Two political events in 1991 had lasting effect on the development of the trade in arms: the dissolution of Soviet Union and the Gulf War

  12. Driving pockels cells in multi-arm lasers

    International Nuclear Information System (INIS)

    Carder, B.M.

    1978-01-01

    This paper describes the method used to drive Pockels cells on the 20-arm Shiva laser for inertial confinement fusion research at the Lawrence Livermore Laboratory. Shiva became operational last fall, and has just completed a series of 20-arm target shots. It uses two pockels cell gates in each laser arm for suppression of amplified spontaneous emission (ASE) that can damage or destroy the target before the main pulse arrives. Two additional Pockels cells are used in the preamplification stages, so that a total of 42 cells must be driven by the pulser system

  13. Energy Optimal Trajectories in Human Arm Motion Aiming for Assistive Robots

    Directory of Open Access Journals (Sweden)

    Lelai Zhou

    2017-01-01

    Full Text Available The energy expenditure in human arm has been of great interests for seeking optimal human arm trajectories. This paper presents a new way for calculating metabolic energy consumption of human arm motions. The purpose is to reveal the relationship between the energy consumption and the trajectory of arm motion, and further, the acceleration and arm orientation contributions. Human arm motion in horizontal plane is investigated by virtue of Qualisys motion capture system. The motion data is post-processed by a biomechanical model to obtain the metabolic expenditure. Results on the arm motion kinematics, dynamics and metabolic energy consumption, are included.

  14. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    Science.gov (United States)

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  15. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  16. Molecular clouds in the Carina arm - the largest objects, associated regions of star formation, and the Carina arm in the Galaxy

    International Nuclear Information System (INIS)

    Grabelsky, D.A.; Cohen, R.S.; Bronfman, L.; Thaddeus, P.

    1988-01-01

    The Columbia CO survey of the southern Galactic plane is used to identify giant molecular clouds and cloud complexes in the Vela-Carina-Centaurus section of the Galaxy. Twenty-seven giant molecular clouds between l = 270 and 300 deg are catalogued and their heliocentric distances given. In addition, 16 clouds at l greater than 300 deg beyond the solar circle extend the catalog to include the very distant portion of the Carina arm. The most massive clouds in the catalog trace the Carina arm over 23 kpc in the plane of the Galaxy. The average mass of these objects is 1.4 x 10 to the 6th solar, and their average spacing along the arm is 700 pc. The composite distribution projected onto the Galactic plane of the largest molecular clouds in the Carina arm and of similarly massive clouds in the first and second quadrants strongly suggests that the Carina and Sagittarius arms form a single spiral arm about 40 kpc in length wrapping two-thirds of the way around the Galaxy. Descriptions of each cloud, including identification of associated star-forming regions, are presented in an appendix. 76 references

  17. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Lab. (ANL), Argonne, IL (United States); Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. Note that some of the instrument observations require mathematical algorithms (retrievals) to convert a measured engineering variable into a useful geophysical measurement. While those types of retrieval measurements are identified, this study does not address particular methods for retrieval uncertainty. As well, the ARM Facility also provides engineered data products, or value-added products (VAPs), based on multiple instrument measurements. This study does not include uncertainty estimates for those data products. We propose here that a total measurement uncertainty should be calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). The study will not expand on methods for computing these uncertainties. Instead, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available in the ARM community through the ARM instrument mentors and their ARM instrument handbooks. As a result, this study will address the first steps towards reporting ARM measurement uncertainty

  18. Putting the Glare of Publicity on International Arms Sales.

    Science.gov (United States)

    Hartman, William

    1992-01-01

    Reports on a United Nations committee recommendation that the Security Council establish a universal register of arms. Suggests that such a register would limit the destabilizing influence of major arms sales on developing nations. Argues that visibility of arms sales may help reduce their number. (DK)

  19. The Role of Ethics in International Arms Transfers

    Science.gov (United States)

    2016-06-01

    i THE ROLE OF ETHICS IN INTERNATIONAL ARMS TRANSFERS BY MAJOR ROB ARNETT A THESIS PRESENTED TO THE FACULTY OF THE SCHOOL OF...War’s Ends” provided the intellectual spark to explore the topic of ethics in international arms sales. Additionally, Dr. Murphy was kind enough to... ethics in American arms transfer policy to determine whether the Just War tradition’s jus ad bellum framework can help policymakers through a complex

  20. Arm to leg coordination in elite butterfly swimmers.

    Science.gov (United States)

    Chollet, D; Seifert, L; Boulesteix, L; Carter, M

    2006-04-01

    This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.

  1. MPL-net at ARM Sites

    Science.gov (United States)

    Spinhirne, J. D.; Welton, E. J.; Campbell, J. R.; Berkoff, T. A.; Starr, David OC. (Technical Monitor)

    2002-01-01

    The NASA MPL-net project goal is consistent data products of the vertical distribution of clouds and aerosol from globally distributed lidar observation sites. The four ARM micro pulse lidars are a basis of the network to consist of over twelve sites. The science objective is ground truth for global satellite retrievals and accurate vertical distribution information in combination with surface radiation measurements for aerosol and cloud models. The project involves improvement in instruments and data processing and cooperation with ARM and other partners.

  2. Neurosurgical robotic arm drilling navigation system.

    Science.gov (United States)

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Safeguarding arms control

    International Nuclear Information System (INIS)

    Flanagan, S.J.

    1988-01-01

    This essay reviews the evolution of various safeguards concepts associated with U.S. Soviet arms control negotiations over the past twenty-five years. It explore in some detail the origins, nature, and effectiveness of the safeguards packages associated with six agreements: the Limited Test Ban Treaty (1963), the SALT I Interim Agreement (1972), the Anti-Ballistic Missile (ABM) Treaty (1972), the Threshold Test Ban Treaty (1974), the Peaceful Nuclear Explosions Treaty (1976) and the SALT II Treaty (1979). Finally, the implications of this historical record for developing future nuclear and conventional arms control accords and for shoring up existing pacts, such as the ABM Treaty, are assessed with a view towards practicable prescriptions for Western policymakers. The treaty eliminating intermediate-range nuclear forces (INF) incorporates several verification safeguards, and it is very likely that analogous measures would be attached to any accord constraining conventional forces in Europe

  4. Manipulator arm for a nuclear reactor vessel inspection device

    International Nuclear Information System (INIS)

    1980-01-01

    A manipulator arm for a reactor vessel in-service inspection apparatus is adapted to transport a transducer array for ultrasonic examination of welds at any point in the vessel. The removal of the inspection device from the reactor vessel in an emergency presents a problem where a relatively long manipulator arm is used. This invention provides an improved arm with means for changing the normal orientation of the arm to a shorter one to permit safe removal of the inspection device from the reactor vessel. (author)

  5. A software radio platform based on ARM and FPGA

    Directory of Open Access Journals (Sweden)

    Yang Xin.

    2016-01-01

    Full Text Available The rapid rise in computational performance offered by computer systems has greatly increased the number of practical software radio applications. A scheme presented in this paper is a software radio platform based on ARM and FPGA. FPGA works as the coprocessor together with the ARM, which serves as the core processor. ARM is used for digital signal processing and real-time data transmission, and FPGA is used for synchronous timing control and serial-parallel conversion. A SPI driver for real-time data transmission between ARM and FPGA under ARM-Linux system is provided. By adopting modular design, the software radio platform is capable of implementing wireless communication functions and satisfies the requirements of real-time signal processing platform for high security and broad applicability.

  6. Natural Resource Extraction, Armed Violence, and Environmental Degradation.

    Science.gov (United States)

    Downey, Liam; Bonds, Eric; Clark, Katherine

    2010-12-01

    The goal of this article is to demonstrate that environmental sociologists cannot fully explain the relationship between humans and the natural world without theorizing a link between natural resource extraction, armed violence, and environmental degradation. The authors begin by arguing that armed violence is one of several overlapping mechanisms that provide powerful actors with the means to (a) prevail over others in conflicts over natural resources and (b) ensure that natural resources critical to industrial production and state power continue to be extracted and sold in sufficient quantities to promote capital accumulation, state power, and ecological unequal exchange. The authors then identify 10 minerals that are critical to the functioning of the U.S. economy and/or military and demonstrate that the extraction of these minerals often involves the use of armed violence. They further demonstrate that armed violence is associated with the activities of the world's three largest mining companies, with African mines that receive World Bank funding, and with petroleum and rainforest timber extraction. The authors conclude that the natural resource base on which industrial societies stand is constructed in large part through the use and threatened use of armed violence. As a result, armed violence plays a critical role in fostering environmental degradation and ecological unequal exchange.

  7. US-Russian relations: the arms control agenda

    International Nuclear Information System (INIS)

    Potter, W.

    2001-01-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  8. US-Russian relations: the arms control agenda

    Energy Technology Data Exchange (ETDEWEB)

    Potter, W

    2001-07-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  9. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Directory of Open Access Journals (Sweden)

    Weitong Hu

    Full Text Available OBJECTIVES: To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r induced by one arm ischemia correlates with flow-mediated dilatation (FMD. METHODS: Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives. Following baseline diameter (D0 and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD was calculated as the percentage increase of artery diameter (ΔD/D0. The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r. RESULTS: At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, P<0.05, which led to an increase of ΔDBPl-r (4.00±3.75 vs 0.78±4.47 mmHg, P<0.05. A positive correlation was seen between ΔD/D0 and ΔDBPl-r (r = 0.744, p<0.001. Furthermore, the correlation between age and ΔDBPl-r (r = -0.358, P<0.01 was similar to that between age and D/D0 (r = -0.398, P<0.01. Meanwhile, both ΔDBPl-r and ΔD/D0 were significantly lower in hypertensive patients than in normotensive patients. CONCLUSION: The inter-arm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  10. Technology-supported training of arm-hand skills in stroke

    NARCIS (Netherlands)

    Timmermans, A.A.A.

    2010-01-01

    Impaired arm-hand performance is a serious consequence of stroke that is associated with reduced self-efficacy and poor quality of life. Task-oriented arm training is a therapy approach that is known to improve skilled arm-hand performance, even in chronic stages after stroke. At the start of this

  11. Kinematic feedback control laws for generating natural arm movements

    International Nuclear Information System (INIS)

    Kim, Donghyun; Jang, Cheongjae; Park, Frank C

    2014-01-01

    We propose a stochastic optimal feedback control law for generating natural robot arm motions. Our approach, inspired by the minimum variance principle of Harris and Wolpert (1998 Nature 394 780–4) and the optimal feedback control principles put forth by Todorov and Jordan (2002 Nature Neurosci. 5 1226–35) for explaining human movements, differs in two crucial respects: (i) the endpoint variance is minimized in joint space rather than Cartesian hand space, and (ii) we ignore the dynamics and instead consider only the second-order differential kinematics. The feedback control law generating the motions can be straightforwardly obtained by backward integration of a set of ordinary differential equations; these equations are obtained exactly, without any linear–quadratic approximations. The only parameters to be determined a priori are the variance scale factors, and for both the two-DOF planar arm and the seven-DOF spatial arm, a table of values is constructed based on the given initial and final arm configurations; these values are determined via an optimal fitting procedure, and consistent with existing findings about neuromuscular motor noise levels of human arm muscles. Experiments conducted with a two-link planar arm and a seven-DOF spatial arm verify that the trajectories generated by our feedback control law closely resemble human arm motions, in the sense of producing nearly straight-line hand trajectories, having bell-shaped velocity profiles, and satisfying Fitts Law. (paper)

  12. Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys

    Science.gov (United States)

    Ifft, Peter J.; Shokur, Solaiman; Li, Zheng; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2014-01-01

    Brain-machine interfaces (BMIs) are artificial systems that aim to restore sensation and movement to severely paralyzed patients. However, previous BMIs enabled only single arm functionality, and control of bimanual movements was a major challenge. Here, we developed and tested a bimanual BMI that enabled rhesus monkeys to control two avatar arms simultaneously. The bimanual BMI was based on the extracellular activity of 374–497 neurons recorded from several frontal and parietal cortical areas of both cerebral hemispheres. Cortical activity was transformed into movements of the two arms with a decoding algorithm called a 5th order unscented Kalman filter (UKF). The UKF is well-suited for BMI decoding because it accounts for both characteristics of reaching movements and their representation by cortical neurons. The UKF was trained either during a manual task performed with two joysticks or by having the monkeys passively observe the movements of avatar arms. Most cortical neurons changed their modulation patterns when both arms were engaged simultaneously. Representing the two arms jointly in a single UKF decoder resulted in improved decoding performance compared with using separate decoders for each arm. As the animals’ performance in bimanual BMI control improved over time, we observed widespread plasticity in frontal and parietal cortical areas. Neuronal representation of the avatar and reach targets was enhanced with learning, whereas pairwise correlations between neurons initially increased and then decreased. These results suggest that cortical networks may assimilate the two avatar arms through BMI control. PMID:24197735

  13. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  14. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    Science.gov (United States)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  15. Primary design of Si cooling arm structure in ICF cryogenic target

    International Nuclear Information System (INIS)

    Zhang Yong; Yi Yong; Tang Changhuan; Zhang Jicheng

    2013-01-01

    According to the requirement of the cryogenic target system to the Si cooling arm structure, the Si cooling arm was primarily designed based on the USA National Ignition Facility (NIF) target. A new three-dimensional model of Si cooling arm was developed by SolidWorks software, and the simulation and analysis of Si cooling arm in aspect of mechanical property, thermal response and assembly were made based on the model. A law about the effect of the arm length of Si cooling arm and the width and the length of bifurcation on Si cooling arm was achieved. The research may provide the theoretical foundation and reference for the further improvement of cryogenic target. (authors)

  16. SIPRI's new conceptual approach to arms control and disarmament

    International Nuclear Information System (INIS)

    Rotfeld, Adam Daniel

    2000-01-01

    The end of the cold war deprioritized arms control and disarmament, and progress in the field was no longer a measure of relations among the major powers. In that context, the future of arms control and disarmament was discussed at the Nobel Symposium in October 1999. Stockholm International Peace Research Institute (SIPRI) views arms control as an instrument for shaping a new inclusive and cooperative security order. The author questions whether arms control challenges today can and should be resolved in the institutions established and the procedures elaborated in the bipolar framework. (author)

  17. Dual Arm Work Module Development and Appplications

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, M.W.

    1999-04-25

    The dual arm work module (DAWM) was developed at Oak Ridge National Laboratory (ORNL) by the Robotics Technology Development Program (RTDP) as a development test bed to study issues related to dual arm manipulation, including platform cotilguration, controls, automation, operations, and tooling. The original platform was based on two Schilling Titan II manipulators mounted to a 5-degree-of- freedom (DOF) base fabricated by RedZone Robotics, Inc. The 5-DOF articulation provided a center torso rotation, linear actuation to change the separation between the arms, and arm base rotation joints to provide "elbows up," elbows down," or "elbows out" orientation. A series of tests were conducted on operations, tooling, and task space scene analysis (TSSA)-driven robotics for overhead transporter- mounted and crane hook-deployed scenarios. A concept was developed for DAWM deployment from a large remote work vehicle, but the project was redirected to support dismantlement of the Chicago Pile #5 (CP-5) reactor at Argonne National Laboratory in fiscal year (FY) 1997. Support of CP-5 required a change in focus of the dual arm technology from that of a development test bed to a system focussed for a specific end user. ORNL teamed with the Idaho National Environmental ,Engineering Laboratory, Sandia National Laboratory, and the Savannah River Technology Center to deliver a crane-deployed derivative of the DAWM, designated the dual arm work platform (DAWP). RTDP staff supported DAWP at CP-5 for one FY; Argonne staff continued operation through to dismantlement of the reactor internals. Lessons learned from this interaction were extensive. Beginning in FY 1999, dual arm development activities are again being pursued in the context of those lessons learned. This paper describes the progression of philosophy of the DAWM from initial test bed to lessons learned through interaction at CP-5 and to the present investigation of telerobotic assist of teleoperation and TSSA- driven robotics.

  18. ARM Enhanced Shortwave Experiment (ARESE) Solar Radiation Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARM Enhanced Shortwave Experiment (ARESE) was conducted at the Department of Energy's ARM Southern Great Plains (SGP) Central Facility between September 22, 1995...

  19. Rosoboroneksport: Arms Sales and the Structure of Russian Defense Industry

    National Research Council Canada - National Science Library

    Blank, Stephen J

    2007-01-01

    In August 2006, the U.S. Government imposed sanctions on Russian arms sellers and producers, Rosoboroneksport, Russia's main arms-selling agency, and Sukhoi, which manufactures aircraft, because of their arms sales to Iran...

  20. Changes in the bilateral pulse transit time difference with a moving arm.

    Science.gov (United States)

    Jiang, Xinge; Wei, Shoushui; Zheng, Dingchang; Huang, Peng; Liu, Chengyu

    2018-04-20

    Changes of pulse transit time (PTT) induced by arm position were studied for unilateral arm. However, consistency of the PTT changes was not validated for both arm sides. We aimed to quantify the PTT changes between horizontal and non-horizontal positions from right arm and left arm in order to explore the consistency of both arms. Twenty-four normal subjects aged between 21 and 50 (14 male and 10 female) years were enrolled. Left and right radial artery pulses were synchronously recorded from 24 healthy subjects with one arm (left or right) at five angles (90∘, 45∘, 0∘, -45∘ and -90∘) and the other arm at the horizontal level (0∘) for reference. The overall mean PTT changes at the five angles (from 90∘ to -90∘) in the left arm (right as reference) were 16.1, 12.3, -0.5, -2.5 and -2.6 ms, respectively, and in the right arm (left as reference) were 18.0, 12.6, 1.6, -1.6 and -2.0 ms, respectively. Obvious differences were not found in the PTT changes between the two arms (left arm moving or right arm moving) under each of the five different positions (all P> 0.05).

  1. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  2. Homosexuality in the Dutch Armed Forces 2006

    NARCIS (Netherlands)

    Anna Adolfsen; Saskia Keuzenkamp; m.m.v. Linda Mans

    2006-01-01

    Original title: Uniform uit de kast. This study looks at the attitudes of defence personnel to homosexuality. How do members of the military view homosexual colleagues? Can gays and lesbians working in the armed forces be open about their sexual preferences? Do they regard the armed forces as

  3. TOWARDS UNIFORM RULES FOR ARMED CONFLICTS Pieter ...

    African Journals Online (AJOL)

    the two Additional Protocols that followed in 1977, divide armed conflict into two legal categories: ... Wounded, Sick and Shipwrecked Members of Armed Forces at Sea. Third Convention ... Nationalist China; ibid 116. ... 17 Pictet op cit 43; Junod, S 'Additional Protocol II: History and Scope' (1983) 33 The. American ...

  4. Limited consensus around ARM information protection practices1

    African Journals Online (AJOL)

    KATUU, Shadrack

    surrounding Information Protection (IP) has been ... compares IP and ARM information protection through .... decision-making methodology used to help ... and differing requirements of institutions into account. ARM literature is prescriptive with.

  5. Nudging Armed Groups: How Civilians Transmit Norms of Protection

    Directory of Open Access Journals (Sweden)

    Oliver Kaplan

    2013-12-01

    Full Text Available What are the varying roles that norms play to either enable or constrain violence in armed conflict settings? The article examines this question by drawing on experiences from communities and armed groups in Colombia and Syria. It begins by presenting an explanation of how norms of violence and nonviolence may arise within communities and influence the behavior of civilian residents, reducing the chances of them becoming involved with armed groups. It then considers how civilian communities can transmit those same norms, shared understandings, and patterns of interaction to the ranks of illegal armed groups and subsequently shape their decisions about the use of violence against civilians. The author argues that civilians may be better positioned to promote the principles codified in International Humanitarian Law than international humanitarian organizations because they have closer contact with irregular armed actors and are viewed with greater legitimacy. The analysis illustrates that to better understand civilian protection mechanisms it is essential to study the interactions between communities and armed actors.

  6. Brigatinib in Patients With Crizotinib-Refractory Anaplastic Lymphoma Kinase-Positive Non-Small-Cell Lung Cancer

    DEFF Research Database (Denmark)

    Kim, Dong-Wan; Tiseo, Marcello; Ahn, Myung-Ju

    2017-01-01

    Purpose Most crizotinib-treated patients with anaplastic lymphoma kinase gene ( ALK)-rearranged non-small-cell lung cancer (ALK-positive NSCLC) eventually experience disease progression. We evaluated two regimens of brigatinib, an investigational next-generation ALK inhibitor, in crizotinib......-up, investigator-assessed confirmed ORR was 45% (97.5% CI, 34% to 56%) in arm A and 54% (97.5% CI, 43% to 65%) in arm B. Investigator-assessed median progression-free survival was 9.2 months (95% CI, 7.4 to 15.6) and 12.9 months (95% CI, 11.1 to not reached) in arms A and B, respectively. Independent review...... (arm A/B, 18%/34%), and were mainly grades 1 to 2. A subset of pulmonary adverse events with early onset (median onset: day 2) occurred in 14 of 219 treated patients (all grades, 6%; grade ≥ 3, 3%); none occurred after escalation to 180 mg in arm B. Seven of 14 patients were successfully retreated...

  7. Cryo-scanning electron microscopy investigation of the Octopus Vulgaris arm structures for the design of an octopus-like arm artefact.

    Science.gov (United States)

    Minnocci, Antonio; Cianchetti, Matteo; Mazzolai, Barbara; Sebastiani, Luca; Laschi, Cecilia

    2015-12-01

    Octopus vulgaris is a cephalopod of the Octopodidae family. It has four pairs of arms and two rows of suckers which perform many functions, including bending and elongation. For this reason the octopus was chosen as model to develop a new generation of soft-body robots. In order to explain some of the fine structures of the octopus arm in relation to its specific ability, we examined the external and internal structures of O. vulgaris arms in a frozen-hydrated state using cryo-scanning electron microscopy. The arms showed skin with a very complex design that is useful to elongation, and a pore pattern distribution on their surface which is functional to cutaneous oxygen uptake. The analysis of freeze-fractured frozen-hydrated arm samples allowed us to describe the developmental differences in the relative proportion of the areas of axial nerve cord, intrinsic and extrinsic musculature, in relation to the growth of the arms and of the increase in functional capability. In the suckers, we analyzed the shedding mechanisms in the outer part of the infundibulum and described the outer and inner characteristics of the denticles, showing in detail their pore system, which is fundamental for their ability to explore the environment. These results are discussed by considering their possible application in the design of new octopus-like artefacts, which will be able to take advantage of some of these ultrastructure characteristics and achieve advanced bioinspired functionalities. © 2015 Wiley Periodicals, Inc.

  8. Galaxy Zoo: constraining the origin of spiral arms

    Science.gov (United States)

    Hart, Ross E.; Bamford, Steven P.; Keel, William C.; Kruk, Sandor J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.

    2018-05-01

    Since the discovery that the majority of low-redshift galaxies exhibit some level of spiral structure, a number of theories have been proposed as to why these patterns exist. A popular explanation is a process known as swing amplification, yet there is no observational evidence to prove that such a mechanism is at play. By using a number of measured properties of galaxies, and scaling relations where there are no direct measurements, we model samples of SDSS and S4G spiral galaxies in terms of their relative halo, bulge and disc mass and size. Using these models, we test predictions of swing amplification theory with respect to directly measured spiral arm numbers from Galaxy Zoo 2. We find that neither a universal cored or cuspy inner dark matter profile can correctly predict observed numbers of arms in galaxies. However, by invoking a halo contraction/expansion model, a clear bimodality in the spiral galaxy population emerges. Approximately 40 per cent of unbarred spiral galaxies at z ≲ 0.1 and M* ≳ 1010M⊙ have spiral arms that can be modelled by swing amplification. This population display a significant correlation between predicted and observed spiral arm numbers, evidence that they are swing amplified modes. The remainder are dominated by two-arm systems for which the model predicts significantly higher arm numbers. These are likely driven by tidal interactions or other mechanisms.

  9. The globalization of the arms industry: The next proliferation challenge

    Energy Technology Data Exchange (ETDEWEB)

    Bitzinger, R.A.

    1994-12-31

    The globalization of the arms industry entails a significant shift away from traditional, single-country patterns of weapons production toward internationalization of the development, production, and marketing of arms. While wholly indigenous armaments production may be on the decline, multinational arms production - through collaboration on individual weapon systems and increasingly via interfirm linkages across the international arms industry - appears actually to be expanding. In several instances, in fact, multinational armaments production is increasingly supplementing or even supplanting indigenous or autonomous weapons production or arms imports. The emergence of an increasingly transnational defense technology and industrial base is fundamentally affecting the shape and content of much of the global arms trade. This changing defense market, in turn, will have a profound impact on a number of national security issues concerning the Western industrialized nations. 3 figs., 2 tabs.

  10. Development of the OPESCOPE mobile C-arm system

    International Nuclear Information System (INIS)

    Tsuji, Hisao; Kadowaki, Toshio; Shimizu, Yasumitsu

    1994-01-01

    A new mobile C-arm X-ray fluoroscopy system called the 'OPESCOPE' equipped with a CCD TV camera and high-definition Image Intensifier has been developed. All the cables for the I.I. and X-ray generator are held inside the C-arm to prevent interference with operation and the C-arm is locked electromagnetically. Moreover, the C-arm is spring counterbalanced in the vertical motion axis. These features enable smooth positioning and uncluttered operation. The X-ray generator uses a high-frequency inverter designed to assure noiseless operation and a compact size. With the new DFS-700 videoprocessor unit being combined, clearer, more informative images can be obtained. In addition to its inherent portability this unit can be upgraded in DSA function to allow angiographic examinations in the surgical theater. (author)

  11. Inter-arm blood pressure differences in young, healthy patients.

    Science.gov (United States)

    Grossman, Alon; Prokupetz, Alex; Gordon, Barak; Morag-Koren, Nira; Grossman, Ehud

    2013-08-01

    The prevalence and magnitude of inter-arm BP difference (IAD) in young healthy patients is not well characterized. Flight academy applicants and designated aviators undergo annual evaluation that includes blood pressure (BP) measurement on both arms. All BP measurements performed from January 1, 2012, to April 30, 2012, were recorded and IAD was calculated. Results were compared between patients in whom BP was initially measured in the right arm (group 1), those in whom BP was initially measured in the left arm (group 2), and those in whom the arm in which BP was initially measured was not recorded (group 3). A total of 877 healthy patients had BP measured during the study period. In the entire group, mean systolic BP was the same in both arms. Absolute IAD was 5.6±5.5 mm Hg for systolic and 4.7±4.5 mm Hg for diastolic BP. IAD >10 mm Hg was recorded in 111 (12.6%) and 77 (8.8%) patients for systolic and diastolic BP, respectively. IAD was the same in the 3 groups and was unrelated to age, body mass index, and heart rate, but was related to systolic BP. IAD is common in young healthy patients, is not dependent on which arm was measured first, and unrelated to age, body mass index, and heart rate. © 2013 Wiley Periodicals, Inc.

  12. Trigonometric parallaxes of star forming regions in the Scutum spiral arm

    International Nuclear Information System (INIS)

    Sato, M.; Wu, Y. W.; Immer, K.; Zhang, B.; Sanna, A.; Brunthaler, A.; Menten, K. M.; Reid, M. J.; Dame, T. M.

    2014-01-01

    We report measurements of trigonometric parallaxes for six high-mass star-forming regions in the Scutum spiral arm of the Milky Way as part of the BeSSeL Survey. Combining our measurements with 10 previous measurements from the BeSSeL Survey yields a total sample of 16 sources in the Scutum arm with trigonometric parallaxes in the Galactic longitude range from 5° to 32°. Assuming a logarithmic spiral model, we estimate a pitch angle of 19.°8 ± 3.°1 for the Scutum arm, which is larger than pitch angles reported for other spiral arms. The high pitch angle of the arm may be due to the arm's proximity to the Galactic bar. The Scutum arm sources show an average peculiar motion of 4 km s –1 slower than the Galactic rotation and 8 km s –1 toward the Galactic center. While the direction of this non-circular motion has the same sign as determined for sources in other spiral arms, the motion toward the Galactic center is greater for the Scutum arm sources.

  13. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [Herzberg Astrophysics, National Research Council Canada, National Science Infrastructure portfolio, 5071 West Saanich Road, Victoria, BC, V9E 2E7 (Canada)

    2014-11-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.

  14. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory

  15. Neck and arm pain syndromes

    DEFF Research Database (Denmark)

    de las Peñas, César Fernández; Cleland, Joshua; Huijbregts, Peter

    approaches.It uniquely addresses the expanding role of the various health care professions which require increased knowledge and skills in screening for contra-indications and recognizing the need for medical-surgical referral. Neck and Arm Pain Syndromes also stresses the integration of experiential......The first of its kind, Neck and Arm Pain Syndromes is a comprehensive evidence- and clinical-based book, covering research-based diagnosis, prognosis and management of neuromusculoskeletal pathologies and dysfunctions of the upper quadrant, including joint, muscle, myofascial and neural tissue...... of the most commonly seen pain syndromes in clinical practice over 800 illustrations demonstrating examination procedures and techniques....

  16. Structure of the S6 spirel arm in the Andromeda galaxy

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1982-01-01

    The distribution of stars across the spiral arm S6 in M 31 within Baade's Field 4 is investigated. It is found that the brightest stars are concentrated to the middle line of the arm where the maximal star density is also observed. The symmetry of the arm S6 may be explained by its position near the corotation radius that followed from the spiral pattern velocity Ωsub(P) approximately 10 km/s kpc determined by the age gradient in the arm S4. The similarity between the structure of the arm S6 and that of the spiral arms near the Sun is pointed out [ru

  17. Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge

    International Nuclear Information System (INIS)

    Li Jinchao; Song Zhiquan; Xu Liuwei; Fu Peng; Guo Bin; Li Sen; Dong Lin; Wang Min

    2014-01-01

    A bridge arm prototype of ITER poloidal field (PF) converter modules has been designed and fabricated. Non-cophase counter parallel connection is chosen as the arm structure of the prototype. Among all factors affecting current sharing, arm structure is the main one. During the design of the arm prototype, a novel method based on inductance matrixes is employed to improve the current sharing of the bridge arm. The test results on the prototype show that the current sharing performance of the arm prototype is much better than relevant design requirement, and that the matrix method is very effective to analyze and solve the current sharing problems of thyristor converters

  18. Feasibility of omitting clinical target volume for limited-disease small cell lung cancer treated with chemotherapy and intensity-modulated radiotherapy

    International Nuclear Information System (INIS)

    Cai, Shuhua; Shi, Anhui; Yu, Rong; Zhu, Guangying

    2014-01-01

    To analyze the feasibility of omitting clinical target volume (CTV) for limited small cell lung cancer treated with chemotherapy and intensity modulated radiotherapy. 89 patients were treated from January 1, 2008 to August 31, 2011, 54 cases were irradiated with target volume without CTV, and 35 cases were irradiated with CTV. Both arms were irradiated post chemotherapy tumor extent and omitted elective nodal irradiation; dose prescription was 95% PTV56-63 Gy/28-35 F/5.6-7 weeks. In the arm without CTV and arm with CTV, the local relapse rates were 16.7% and 17.1% (p = 0.586) respectively. In the arm without CTV, of the 9 patients with local relapse, 6 recurred in-field, 2 recurred in margin, 1 recurred out of field. In the arm with CTV, of the 6 patients with local relapse, 4 recurred in-field, 1 recurred in margin, 1 recurred out of field. The distant metastases rates were 42.6% and 51.4% (p = 0.274) respectively. Grade 3-4 hematological toxicity and radiation esophagitis had no statistically significant, but grade 3-4 radiation pneumonia was observed in only 7.4% in the arm without CTV, compared 22.9% in the arm with CTV (p = 0.040). The median survival in the arm without CTV had not reached, compared with 38 months in the with CTV arm. The l- years, 2- years, 3- years survival rates of the arm without CTV and the arm with CTV were 81.0%, 66.2%, 61.5% and 88.6%, 61.7%, 56.6% (p = 0.517). The multivariate analysis indicated that the distant metastases (p = 0.000) and PCI factor (p = 0.004) were significantly related to overall survival. Target delineation omitting CTV for limited-disease small cell lung cancer received IMRT was feasible. The distant metastases and PCI factor were significantly related to overall survival

  19. CHARACTERIZING SPIRAL ARM AND INTERARM STAR FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Kreckel, K.; Schinnerer, E.; Meidt, S. [Max Planck Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanc, G. A. [Departamento de Astronomía, Universidad de Chile, Camino del Observatorio 1515, Las Condes, Santiago (Chile); Groves, B. [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Adamo, A. [Department of Astronomy, The Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Hughes, A., E-mail: kreckel@mpia.de [CNRS, IRAP, 9 Av. du Colonel Roche, BP 44346, F-31028 Toulouse cedex 4 (France)

    2016-08-20

    Interarm star formation contributes significantly to a galaxy’s star formation budget and provides an opportunity to study stellar birthplaces unperturbed by spiral arm dynamics. Using optical integral field spectroscopy of the nearby galaxy NGC 628 with VLT/MUSE, we construct H α maps including detailed corrections for dust extinction and stellar absorption to identify 391 H ii regions at 35 pc resolution over 12 kpc{sup 2}. Using tracers sensitive to the underlying gravitational potential, we associate H ii regions with either arm (271) or interarm (120) environments. Using our full spectral coverage of each region, we find that most physical properties (luminosity, size, metallicity, ionization parameter) of H ii regions are independent of environment. We calculate the fraction of H α luminosity due to the background of diffuse ionized gas (DIG) contaminating each H ii region, and find the DIG surface brightness to be higher within H ii regions than in the surroundings, and slightly higher within arm H ii regions. Use of the temperature-sensitive [S ii]/H α line ratio instead of the H α surface brightness to identify the boundaries of H ii regions does not change this result. Using the dust attenuation as a tracer of the gas, we find depletion times consistent with previous work (2 × 10{sup 9} yr) with no differences between the arm and interarm, but this is very sensitive to the DIG correction. Unlike molecular clouds, which can be dynamically affected by the galactic environment, we see fairly consistent properties of H ii regions in both arm and interarm environments. This suggests either a difference in star formation and feedback in arms or a decoupling of dense star-forming clumps from the more extended surrounding molecular gas.

  20. Effect of arm swing strategy on local dynamic stability of human gait.

    Science.gov (United States)

    Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H

    2015-02-01

    Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. The European Union and armed drones: framing the debate

    DEFF Research Database (Denmark)

    Martins, Bruno Oliveira

    2015-01-01

    Armed drones are an issue extremely relevant for the EU. The recent emergence of targeted killings as a common counter-terrorism technique, the existence of several EU member states using armed and surveillance drones in military scenarios, the presence of member states troops in areas where armed...... drones have been active, the US use of European-originated intelligence to execute targeted killings, and the broader status of international law, are developments that illustrate the importance of the topic. Yet, the EU still does not have an official position on armed drones. In 2014 the European...... Parliament recognized that this is problematic, adopting a Resolution that expressed “grave concern over the use of armed drones outside the international legal framework” and that urged the EU to “develop an appropriate policy response at both European and global level”. This Forum answers to the European...

  2. Fractures of the humerus during arm wrestling

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko Ž.

    2014-01-01

    Full Text Available Background/Aim. Humeral shaft fractures may occur as a result of arm wrestling. The aim of this study was to present our treatment of humerus fracture sustained during arm wrestling. Methods. A total of six patients, aged 22 to 48, were treated at our department form January 2008 to January 2010 with open reduction and internal fixation and with hanging arm casts. A review of all the relevant literature on the subject was also presented. Results. In all the cases, the fractures healed and function returned to normal. No patient had any neural or vascular compromise. Conclusion. Closed and operative treatments were equally successful in all reported cases. [Projekat Ministarstva nauke Republike Srbije, br. 175-095

  3. ARM Climate Research Facility Annual Report 2005

    Energy Technology Data Exchange (ETDEWEB)

    J. Voyles

    2005-12-31

    Through the ARM Program, the DOE funded the development of several highly instrumented ground stations for studying cloud formation processes and their influence on radiative transfer, and for measuring other parameters that determine the radiative properties of the atmosphere. This scientific infrastructure, and resultant data archive, is a valuable national and international asset for advancing scientific knowledge of Earth systems. In fiscal year (FY) 2003, the DOE designated ARM sites as a national scientific user facility: the ARM Climate Research (ACRF). The ACRF has enormous potential to contribute to a wide range interdisciplinary science in areas such as meteorology, atmospheric aerosols, hydrology, biogeochemical cycling, and satellite validation, to name only a few.

  4. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  5. The metabolic cost of human running: is swinging the arms worth it?

    Science.gov (United States)

    Arellano, Christopher J; Kram, Rodger

    2014-07-15

    Although the mechanical function is quite clear, there is no consensus regarding the metabolic benefit of arm swing during human running. We compared the metabolic cost of running using normal arm swing with the metabolic cost of running while restricting the arms in three different ways: (1) holding the hands with the arms behind the back in a relaxed position (BACK), (2) holding the arms across the chest (CHEST) and (3) holding the hands on top of the head (HEAD). We hypothesized that running without arm swing would demand a greater metabolic cost than running with arm swing. Indeed, when compared with running using normal arm swing, we found that net metabolic power demand was 3, 9 and 13% greater for the BACK, CHEST and HEAD conditions, respectively (all Prunning without arm swing, subjects significantly increased the peak-to-peak amplitudes of both shoulder and pelvis rotation about the vertical axis, most likely a compensatory strategy to counterbalance the rotational angular momentum of the swinging legs. In conclusion, our findings support our general hypothesis that swinging the arms reduces the metabolic cost of human running. Our findings also demonstrate that arm swing minimizes torso rotation. We infer that actively swinging the arms provides both metabolic and biomechanical benefits during human running. © 2014. Published by The Company of Biologists Ltd.

  6. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Laboratory; Sisterson, DL [Argonne National Laboratory

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily-accessible, well-articulated estimate of ARM measurement uncertainty is needed.

  7. Participation in Armed Forces, National, and International Sports Activities

    Science.gov (United States)

    1987-03-09

    American Games , Olympic Games , and other authorized national and international sports competitions (to include qualifying and preparatory events) as long...concerning the participation of Armed Forces personnel in Armed Forces, national, and international sports competitions ; establishes a Senior Military Sports ...program is to ensure that the U.S. Armed Forces are appropriately represented in national and international sports competitions . 3. The purpose of this

  8. The effect of arm sling on balance in patients with hemiplegia.

    Science.gov (United States)

    Acar, Merve; Karatas, Gulcin Kaymak

    2010-10-01

    The aim of this study was to investigate the effect of an arm sling on balance in patients with, hemiplegia following a stroke. Twenty-six patients with hemiplegia (11 men, 15 women) who had, shoulder subluxation were enrolled in the study. Balance was evaluated by the Berg Balance Scale, the, Functional Reach test, and a static balance index which was measured by the Kinesthetic Ability, Trainer 3000. Balance tests were performed twice, with arm sling and without arm sling use. Results of, this study show that the Berg Balance Scores and static balance index ameliorated with arm sling use (p=0.005 and p=0.004, respectively). Likewise, the Functional Reach test was better when performed with an arm sling (p=0.039). In conclusion, arm slings have a beneficial effect on balance in patients, with hemiplegia. An arm sling may be applied for its possible beneficial effect on balance especially in, the early phases of stroke rehabilitation while the upper extremity is still flaccid and arm swing is, reduced. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Spiral arms, comets and terrestrial catastrophism

    International Nuclear Information System (INIS)

    Clube, S.V.M.; Napier, W.M.

    1982-01-01

    A review is presented of an hypothesis of terrestrial catastrophism in which comets grow in molecular clouds and are captured by the Sun as it passes through the spiral arms of the Galaxy. Assuming that comets are a major supplier of the Earth-crossing (Appollo) asteroid population, the latter fluctuates correspondingly and leads to episodes of terrestrial bombardment. Changes in the rotational momentum of core and mantle, generated by impacts, lead to episodes of magnetic field reversal and tectonic activity, while surface phenomena lead to ice-ages and mass extinctions. An episodic geophysical history with an interstellar connection is thus implied. If comets in spiral arms are necessary intermediaries in the process of star formation, the theory also has implications relating to early solar system history and galactic chemistry. These aspects are briefly discussed with special reference to the nature of spiral arms. (author)

  10. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  11. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C-arm

  12. Design and analysis on robotic arm for serving hazard container

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam

    2017-09-01

    This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.

  13. The Influences of Arm Resist Motion on a CAR Crash Test Using Hybrid III Dummy with Human-Like Arm

    Science.gov (United States)

    Kim, Yongchul; Youm, Youngil; Bae, Hanil; Choi, Hyeonki

    Safety of the occupant during the crash is very essential design element. Many researches have been investigated in reducing the fatal injury of occupant. They are focusing on the development of a dummy in order to obtain the real human-like motion. However, they have not considered the arm resist motion during the car accident. In this study, we would like to suggest the importance of the reactive force of the arm in a car crash. The influences of reactive force acting on the human upper extremity were investigated using the impedance experimental method with lumped mass model of hand system and a Hybrid III dummy with human-like arm. Impedance parameters (e.g. inertia, spring constant and damping coefficient) of the elbow joint in maximum activation level were measured by free oscillation test using single axis robot. The results showed that without seat belt, the reactive force of human arm reduced the head, chest, and femur injury, and the flexion moment of the neck is higher than that of the conventional dummy.

  14. AN OUTER ARM IN THE SECOND GALACTIC QUADRANT: STRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Du, Xinyu; Xu, Ye; Yang, Ji; Sun, Yan; Li, Facheng; Zhang, Shaobo; Zhou, Xin, E-mail: xydu@pmo.ac.cn, E-mail: xuye@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Science, Nanjing 210008 (China)

    2016-05-01

    The lack of arm tracers, especially remote tracers, is one of the most difficult problems preventing us from studying the structure of the Milky Way. Fortunately, with its high-sensitivity CO survey, the Milky Way Imaging Scroll Painting (MWISP) project offers such an opportunity. Since completing about one-third of its mission, an area of l = [100, 150]°, b = [−3, 5]° has nearly been covered. The Outer arm of the Milky Way first clearly revealed its shape in the second galactic quadrant in the form of molecular gas—this is the first time that the Outer arm has been reported in such a large-scale mapping of molecular gas. Using the 115 GHz {sup 12}CO(1–0) data of MWISP at the LSR velocity ≃[−100, −60] km s{sup −1} and in the area mentioned above, we have detected 481 molecular clouds in total, and among them 332 (about 69%) are newly detected and 457 probably belong to the Outer arm. The total mass of the detected Outer arm clouds is ∼3.1 × 10{sup 6} M {sub ⊙}. Assuming that the spiral arm is a logarithmic spiral, the pitch angle is fitted as ∼13.°1. Besides combining both the CO data from MWISP and the 21 cm H i data from the Canadian Galactic Plane Survey (CGPS), the gas distribution, warp, and thickness of the Outer arm are also studied.

  15. Armed guards on vessels : insurance and liability

    Directory of Open Access Journals (Sweden)

    Mišo Mudrić

    2011-12-01

    Full Text Available The Paper examines the insurance and liability issues resulting from the use of armed guards on board vessels. The study begins with an overview of the available data on key economic fi gures representing the projected overall annual costs of modern piracy. The focus is then shifted to the issue of public versus private security, where possible dangers of private-based security options are discussed in general. After explaining why the Somalia region deserves a closer attention when compared to other pirate-infested waters, a brief summary of the international effort to combat piracy threat is presented, followed by a structured overview of the use of private maritime security options in the maritime sector in general. One security option is the use of armed guards on board vessels. This option is explored both from the political (the acceptance by stakeholders and legal standpoint (legal issues arising from the use of armed guards. An important remedy for the shipping companies/ operators threatened by the piracy hazard is the existence of affordable and effective (specialized marine insurance. A study of available piracy insurance policies is presented, followed by an analysis of case law and other legal issues arising from piracy attacks, which could prove important when considering the legal implications of armed guards employment. Finally, a simplifi ed economic analysis of available security options is presented, followed by the final assessment of benefi ts derived from the use of armed guards.

  16. Analyst Tools and Quality Control Software for the ARM Data System

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.T.

    2004-12-14

    ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

  17. Calcium regulates ATP-sensitive microtubule binding by Chlamydomonas outer arm dynein.

    Science.gov (United States)

    Sakato, Miho; King, Stephen M

    2003-10-31

    The Chlamydomonas outer dynein arm contains three distinct heavy chains (alpha, beta, and gamma) that exhibit different motor properties. The LC4 protein, which binds 1-2 Ca2+ with KCa = 3 x 10-5 m, is associated with the gamma heavy chain and has been proposed to act as a sensor to regulate dynein motor function in response to alterations in intraflagellar Ca2+ levels. Here we genetically dissect the outer arm to yield subparticles containing different motor unit combinations and assess the microtubule-binding properties of these complexes both prior to and following preincubation with tubulin and ATP, which was used to inhibit ATP-insensitive (structural) microtubule binding. We observed that the alpha heavy chain exhibits a dominant Ca2+-independent ATP-sensitive MT binding activity in vitro that is inhibited by attachment of tubulin to the structural microtubule-binding domain. Furthermore, we show that ATP-sensitive microtubule binding by a dynein subparticle containing only the beta and gamma heavy chains does not occur at Ca2+ concentrations below pCa 6 but is maximally activated above pCa 5. This activity was not observed in mutant dyneins containing small deletions in the microtubule-binding region of the beta heavy chain or in dyneins that lack both the alpha heavy chain and the motor domain of the beta heavy chain. These findings strongly suggest that Ca2+ binding directly to a component of the dynein complex regulates ATP-sensitive interactions between the beta heavy chain and microtubules and lead to a model for how individual motor units are controlled within the outer dynein arm.

  18. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  19. Optimization on robot arm machining by using genetic algorithms

    Science.gov (United States)

    Liu, Tung-Kuan; Chen, Chiu-Hung; Tsai, Shang-En

    2007-12-01

    In this study, an optimization problem on the robot arm machining is formulated and solved by using genetic algorithms (GAs). The proposed approach adopts direct kinematics model and utilizes GA's global search ability to find the optimum solution. The direct kinematics equations of the robot arm are formulated and can be used to compute the end-effector coordinates. Based on these, the objective of optimum machining along a set of points can be evolutionarily evaluated with the distance between machining points and end-effector positions. Besides, a 3D CAD application, CATIA, is used to build up the 3D models of the robot arm, work-pieces and their components. A simulated experiment in CATIA is used to verify the computation results first and a practical control on the robot arm through the RS232 port is also performed. From the results, this approach is proved to be robust and can be suitable for most machining needs when robot arms are adopted as the machining tools.

  20. A Scintigraphic Method for Quantitation of Lymphatic Function in Arm Lymphedema

    DEFF Research Database (Denmark)

    Hvidsten, Svend; Toyserkani, Navid M; Sørensen, Jens A

    2018-01-01

    ) measure of lymph fluid passing through the arm. METHODS AND RESULTS: Eleven patients, aged 34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent simultaneous bilateral lymphoscintigraphy using intradermal injection of 99mTc-labeled human serum albumin (HSA). Imaging...... was performed at 30-45 minute intervals for 5 hours. Time activity curves from each injection site and each arm region were recorded. The input into the arm region was obtained as the (minus) time derivative of the injection site activity curve. In the proposed model the arm activity curve was considered...

  1. The Lifferth Dome for Small Telescopes

    Science.gov (United States)

    Wilson, B. L.; Olsen, C. S.; Iverson, E. P.; Paget, A.; Lifferth, W.; Brown, P. J.; Moody, J. W.

    2004-12-01

    The Lifferth Dome is a pull-off roof designed for small telescopes and other observational equipment. It was specifically designed for the needs of the ROVOR project. The roof itself is completely removed from the observatory housing walls and cranked off to the side below the optical horizon. This is done using two swing arms on either side of the observatory that work in unison to lift the roof off the structure and rotate down and away into a cleared location. The torque is provided by a threaded rod connected to an electric motor at the back of the building. As the motor rotates, the threads turn through a threaded sleeve connected directly to the support arms. Advantages to this design are no lost horizon, no roller surfaces to keep clean, low power and simple limit switches. Operation is by computer control using by National Instruments LabVIEW via the internet. We present its design and construction.

  2. Analysis of hypothetical loss-of-control-arm accidents in HIFAR

    International Nuclear Information System (INIS)

    Connolly, J.W.; Clark, N.

    1986-11-01

    The reactor power transient produced in the HIFAR materials testing reactor upon severance of a central coarse control arm connecting rod and the subsequent pivoting of the arm out of the core has been calculated for a range of reactor conditions likely to be encountered in normal operation. It is concluded that as long as the remaining arms of the control arm bank can be relied on to suppress the post power peak oscillations in power, the reactor will withstand the consequences of such an accident

  3. Minimum Q Electrically Small Antennas

    DEFF Research Database (Denmark)

    Kim, O. S.

    2012-01-01

    Theoretically, the minimum radiation quality factor Q of an isolated resonance can be achieved in a spherical electrically small antenna by combining TM1m and TE1m spherical modes, provided that the stored energy in the antenna spherical volume is totally suppressed. Using closed-form expressions...... for a multiarm spherical helix antenna confirm the theoretical predictions. For example, a 4-arm spherical helix antenna with a magnetic-coated perfectly electrically conducting core (ka=0.254) exhibits the Q of 0.66 times the Chu lower bound, or 1.25 times the minimum Q....

  4. Overview of Actuated Arm Support Systems and Their Applications

    Directory of Open Access Journals (Sweden)

    E.A. Lomonova

    2013-10-01

    Full Text Available Arm support systems provide support throughout daily tasks, training or in an industrial environment. During the last decades a large diversity of actuated arm support systems have been developed. To analyze the actuation principles in these systems, an overview of actuated arm support systems is provided. This overview visualizes the current trends on research and development of these support systems and distinguishes three categories. These categories depend mainly on the functional status of the user environment, which defines the specifications. Therefore, the actuated arm support systems are classified according to their user environment, namely: ambulatory, rehabilitation and industrial. Furthermore, three main actuation principles and three mechanical construction principles have been identified.

  5. Mid-upper-arm-circumference and mid-upper-arm circumference z-score

    DEFF Research Database (Denmark)

    Rasmussen, J; Andersen, A; Fisker, A B

    2012-01-01

    Mid-upper-arm circumference (MUAC) is a simple method of assessing nutritional status in children above 6 months of age. In 2007 World Health Organization (WHO) introduced a MUAC z-score for children above 3 months of age. We evaluated whether MUAC or MUAC z-score had the best ability to identify...

  6. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  7. Systems Approach to Arms Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, K; Neimeyer, I; Listner, C; Stein, G; Chen, C; Dreicer, M

    2015-05-15

    Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.

  8. Smooth-arm spiral galaxies: their properties and significance to cluster-galaxy evolution

    International Nuclear Information System (INIS)

    Wilkerson, M.S.

    1979-01-01

    In this dissertation a number of galaxies with optical appearances between those of normal, actively-star-forming spirals and SO galaxies have been examined. These so-called smooth-arm spiral galaxies exhibit spiral arms without any of the spiral tracers - H II regions, O-B star associations, dust - indicative of current star formation. Tests were made to find if, perhaps, these smooth-arm spirals could have, at one time, been normal, actively-star-forming spirals whose gas had been somehow removed; and that are currently transforming into SO galaxies. This scenario proceeds as (1) removal of gas, (2) gradual dying of disk density wave, (3) emergence of SO galaxy. If the dominant method of gas removal is ram-pressure stripping by a hot, intracluster medium, then smooth-arm spirals should occur primarily in x-ray clusters. Some major findings of this dissertation are as follows: (1) Smooth-arm spirals are redder than normal spirals of the same morphological type. Most smooth-arm spirals cannot be distinguished by color from SO galaxies. (2) A weak trend exists for smooth-arm spirals with stronger arms to be bluer than those with weaker arms; thus implying that the interval since gas removal has been shorter for the galaxies with stronger arms. (3) Smooth-arm spirals are deficient in neutral hydrogen - sometimes by an order of magnitude or, possibly, more

  9. Lightweight Small Arms Technologies

    Science.gov (United States)

    2006-11-01

    conducted using several methods. Initial measurements were obtained using a strand burner , followed by closed bomb measurements using both pressed... pellets and entire cases. Specialized fixtures were developed to measure primer and booster combustion properties. The final verification of interior

  10. Dynamic model of the octopus arm. II. Control of reaching movements.

    Science.gov (United States)

    Yekutieli, Yoram; Sagiv-Zohar, Roni; Hochner, Binyamin; Flash, Tamar

    2005-08-01

    The dynamic model of the octopus arm described in the first paper of this 2-part series was used here to investigate the neural strategies used for controlling the reaching movements of the octopus arm. These are stereotypical extension movements used to reach toward an object. In the dynamic model, sending a simple propagating neural activation signal to contract all muscles along the arm produced an arm extension with kinematic properties similar to those of natural movements. Control of only 2 parameters fully specified the extension movement: the amplitude of the activation signal (leading to the generation of muscle force) and the activation traveling time (the time the activation wave takes to travel along the arm). We found that the same kinematics could be achieved by applying activation signals with different activation amplitudes all exceeding some minimal level. This suggests that the octopus arm could use minimal amplitudes of activation to generate the minimal muscle forces required for the production of the desired kinematics. Larger-amplitude signals would generate larger forces that increase the arm's stability against perturbations without changing the kinematic characteristics. The robustness of this phenomenon was demonstrated by examining activation signals with either a constant or a bell-shaped velocity profile. Our modeling suggests that the octopus arm biomechanics may allow independent control of kinematics and resistance to perturbation during arm extension movements.

  11. A prognostic scoring system for arm exercise stress testing.

    Science.gov (United States)

    Xie, Yan; Xian, Hong; Chandiramani, Pooja; Bainter, Emily; Wan, Leping; Martin, Wade H

    2016-01-01

    Arm exercise stress testing may be an equivalent or better predictor of mortality outcome than pharmacological stress imaging for the ≥50% for patients unable to perform leg exercise. Thus, our objective was to develop an arm exercise ECG stress test scoring system, analogous to the Duke Treadmill Score, for predicting outcome in these individuals. In this retrospective observational cohort study, arm exercise ECG stress tests were performed in 443 consecutive veterans aged 64.1 (11.1) years. (mean (SD)) between 1997 and 2002. From multivariate Cox models, arm exercise scores were developed for prediction of 5-year and 12-year all-cause and cardiovascular mortality and 5-year cardiovascular mortality or myocardial infarction (MI). Arm exercise capacity in resting metabolic equivalents (METs), 1 min heart rate recovery (HRR) and ST segment depression ≥1 mm were the stress test variables independently associated with all-cause and cardiovascular mortality by step-wise Cox analysis (all pstatistic of 0.81 before and 0.88 after adjustment for significant demographic and clinical covariates. Arm exercise scores for the other outcome end points yielded C-statistic values of 0.77-0.79 before and 0.82-0.86 after adjustment for significant covariates versus 0.64-0.72 for best fit pharmacological myocardial perfusion imaging models in a cohort of 1730 veterans who were evaluated over the same time period. Arm exercise scores, analogous to the Duke Treadmill Score, have good power for prediction of mortality or MI in patients who cannot perform leg exercise.

  12. The purposes, achievements, and priorities of arms control

    International Nuclear Information System (INIS)

    Brown, P.S.

    1987-09-01

    Arms control purposes include strengthening the framework of deterrence and reducing the threat of the use of nuclear weapons, reducing the dangers of attack and accidental nuclear war, and allowing more resources for the civilian economy. The paper briefly describes achievements in arms control since World War II. These include the Limited Test Ban Treaty (LTBT), Nonproliferation Treaty (NPT), Anti-Ballistic Missile Treaty (ABMT)-SALT I, SALT II, Threshold Test Ban Treaty (TTBT), Peaceful Nuclear Explosions Treaty (PNET), and Nuclear-Free Zones treaties. The author also discusses his views on what the priorities of arms control activities should be

  13. Interventional C-arm tomosynthesis for vascular imaging: initial results

    Science.gov (United States)

    Langan, David A.; Claus, Bernhard E. H.; Al Assad, Omar; Trousset, Yves; Riddell, Cyril; Avignon, Gregoire; Solomon, Stephen B.; Lai, Hao; Wang, Xin

    2015-03-01

    As percutaneous endovascular procedures address more complex and broader disease states, there is an increasing need for intra-procedure 3D vascular imaging. In this paper, we investigate C-Arm 2-axis tomosynthesis ("Tomo") as an alternative to C-Arm Cone Beam Computed Tomography (CBCT) for workflow situations in which the CBCT acquisition may be inconvenient or prohibited. We report on our experience in performing tomosynthesis acquisitions with a digital angiographic imaging system (GE Healthcare Innova 4100 Angiographic Imaging System, Milwaukee, WI). During a tomo acquisition the detector and tube each orbit on a plane above and below the table respectively. The tomo orbit may be circular or elliptical, and the tomographic half-angle in our studies varied from approximately 16 to 28 degrees as a function of orbit period. The trajectory, geometric calibration, and gantry performance are presented. We overview a multi-resolution iterative reconstruction employing compressed sensing techniques to mitigate artifacts associated with incomplete data reconstructions. In this work, we focus on the reconstruction of small high contrast objects such as iodinated vasculature and interventional devices. We evaluate the overall performance of the acquisition and reconstruction through phantom acquisitions and a swine study. Both tomo and comparable CBCT acquisitions were performed during the swine study thereby enabling the use of CBCT as a reference in the evaluation of tomo vascular imaging. We close with a discussion of potential clinical applications for tomo, reflecting on the imaging and workflow results achieved.

  14. Beyond arms control? Looking for the lost paradigm.

    International Nuclear Information System (INIS)

    Dahan, P.

    2002-01-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  15. Comparison of upper arm and forearm blood pressure.

    Science.gov (United States)

    Domiano, Kathy L; Hinck, Susan M; Savinske, Debra L; Hope, Kathryn L

    2008-11-01

    The upper arm is the primary site used to obtain a blood pressure measurement (BPM); however, when it is not possible to use the upper arm, the forearm is a commonly used alternate site. This study determines if there is a significant difference between upper arm and forearm BPMs among adults and examines the relationship of participant characteristics to the BPM difference. A convenience sample was recruited from a low-income, independent-living, 104-apartment complex in the Midwest. Of the 106 participants, 64% were female and 89% were White. Ages ranged from 20 to 85 years (M = 50.7). The investigators calculated the BMIs (range = 18 to 42, M = 29.3, SD = 5.4) for the 89% (n = 94) of participants who reported their weight. The forearm tended to have higher BPMs than the upper arm (M difference = 4.0 mm Hg systolic, 2.3 mm Hg diastolic). However, site differences were greatest for men, obese adults, and middle aged (36 to 65) adults.

  16. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  17. WORKSPACE DRAWING FROM A MANIPULATOR ARM WITH 6 DOF

    Directory of Open Access Journals (Sweden)

    NAIDIN Gigi

    2011-06-01

    Full Text Available Modelling and simulation is an important aspect in robotic field. Knowing of the workspace is very important to the operation of manipulators arm. This paper investigates operational performance of space manipulator arm destined for industrial manufacturing, by defining and analyzing their workspace and manipulability measure. The authors show that manipulator arm developing requires the consideration of more efficient dynamic models and use of dedicated processing techniques such as Autodesk-Inventor 9, MATLAB, WorkSpace software.

  18. Chaotic evolution of arms races

    Science.gov (United States)

    Tomochi, Masaki; Kono, Mitsuo

    1998-12-01

    A new set of model equations is proposed to describe the evolution of the arms race, by extending Richardson's model with special emphases that (1) power dependent defensive reaction or historical enmity could be a motive force to promote armaments, (2) a deterrent would suppress the growth of armaments, and (3) the defense reaction of one nation against the other nation depends nonlinearly on the difference in armaments between two. The set of equations is numerically solved to exhibit stationary, periodic, and chaotic behavior depending on the combinations of parameters involved. The chaotic evolution is realized when the economic situation of each country involved in the arms race is quite different, which is often observed in the real world.

  19. Information booklet on personal protective equipment: arm and hand protection

    International Nuclear Information System (INIS)

    1992-01-01

    Fire, heat, cold, electro-magnetic and ionising radiation, electricity, chemicals, impacts, cuts, abrasion, etc. are the common hazards for arms and hands at work. The gloves chosen for protection of the arm and hand should cover those parts adequately and the material of the gloves should be capable of offering protection against the specific hazard involved. Criteria for choosing arm and hand protection equipment will be based on their shape and part of the arm and hand protected. Guide lines for choosing such personal protection equipment for nuclear facilities are given. (M.K.V.). 3 annexures, 1 appendix

  20. The arms race control; Le controle de la course aux armements

    Energy Technology Data Exchange (ETDEWEB)

    Nemo, J.

    2010-07-15

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  1. Beyond arms control? Looking for the lost paradigm..; Au-dela de l'arms control? A la recherche du paradigme perdu..

    Energy Technology Data Exchange (ETDEWEB)

    Dahan, P

    2002-07-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  2. Coat of Arms.

    Science.gov (United States)

    Smith, Bryan

    1998-01-01

    Describes an activity, the "coat of arms," that can serve as an ice-breaker or warm-up for the first day of an English-as-a-Second/Foreign-Language class, as a motivating start to the week, or act as an innovative segue between skill lessons. The technique can be adapted for students ranging from elementary school to adult language learners of all…

  3. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  4. G141.2+5.0, A NEW PULSAR WIND NEBULA DISCOVERED IN THE CYGNUS ARM OF THE MILKY WAY

    Energy Technology Data Exchange (ETDEWEB)

    Kothes, R.; Foster, T. J. [National Research Council Herzberg, Dominion Radio Astrophysical Observatory, P.O. Box 248, Penticton, British Columbia, V2A 6J9 (Canada); Sun, X. H. [Sydney Institute for Astronomy, School of Physics, The University of Sydney, NSW 2006 (Australia); Reich, W., E-mail: roland.kothes@nrc-cnrc.gc.ca [Max-Planck-Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany)

    2014-04-01

    We report the discovery of the new pulsar wind nebula (PWN) G141.2+5.0 in data observed with the Dominion Radio Astrophysical Observatory's Synthesis Telescope at 1420 MHz. The new PWN has a diameter of about 3.'5, which translates to a spatial extent of about 4 pc at a distance of 4.0 kpc. It displays a radio spectral index of α ≈ –0.7, similar to the PWN G76.9+1.1. G141.2+5.0 is highly polarized up to 40% with an average of 15% in the 1420 MHz data. It is located in the center of a small spherical H I bubble, which is expanding at a velocity of 6 km s{sup –1} at a systemic velocity of v {sub LSR} = –53 km s{sup –1}. The bubble could be the result of the progenitor star's mass loss or the shell-type supernova remnant (SNR) created by the same supernova explosion in a highly advanced stage. The systemic LSR velocity of the bubble shares the velocity of H I associated with the Cygnus spiral arm, which is seen across the second and third quadrants and an active star-forming arm immediately beyond the Perseus arm. A kinematical distance of 4 ± 0.5 kpc is found for G141.2+5.0, similar to the optical distance of the Cygnus arm (3.8 ± 1.1 kpc). G141.2+5.0 represents the first radio PWN discovered in 17 years and the first SNR discovered in the Cygnus spiral arm, which is in stark contrast with the Perseus arm's overwhelming population of shell-type remnants.

  5. Hysteresis of targeting civilians in armed conflicts

    OpenAIRE

    Uih Ran Lee

    2015-01-01

    This article explores warring groups’ intentional targeting behavior against civilians, a strictly prohibited war strategy by international norms. Using dynamic panel regressions run on a comprehensive dataset of contemporary warfare which covers 22 years (1989-2010), I find that warring actors, both sovereign states and formally organized armed groups, behave systematically in terms of civilian targeting when they are involved in prolonged armed conflict (15-22 years). Warring actors’ lethal...

  6. Relaxation near Supermassive Black Holes Driven by Nuclear Spiral Arms: Anisotropic Hypervelocity Stars, S-stars, and Tidal Disruption Events

    Energy Technology Data Exchange (ETDEWEB)

    Hamers, Adrian S. [Institute for Advanced Study, School of Natural Sciences, Einstein Drive, Princeton, NJ 08540 (United States); Perets, Hagai B., E-mail: hamers@ias.edu [Technion—Israel Institute of Technology, Haifa 32000 (Israel)

    2017-09-10

    Nuclear spiral arms are small-scale transient spiral structures found in the centers of galaxies. Similarly to their galactic-scale counterparts, nuclear spiral arms can perturb the orbits of stars. In the case of the Galactic center (GC), these perturbations can affect the orbits of stars and binaries in a region extending to several hundred parsecs around the supermassive black hole (SMBH), causing diffusion in orbital energy and angular momentum. This diffusion process can drive stars and binaries to close approaches with the SMBH, disrupting single stars in tidal disruption events (TDEs), or disrupting binaries, leaving a star tightly bound to the SMBH and an unbound star escaping the galaxy, i.e., a hypervelocity star (HVS). Here, we consider diffusion by nuclear spiral arms in galactic nuclei, specifically the Milky Way GC. We determine nuclear-spiral-arm-driven diffusion rates using test-particle integrations and compute disruption rates. Our TDE rates are up to 20% higher compared to relaxation by single stars. For binaries, the enhancement is up to a factor of ∼100, and our rates are comparable to the observed numbers of HVSs and S-stars. Our scenario is complementary to relaxation driven by massive perturbers. In addition, our rates depend on the inclination of the binary with respect to the Galactic plane. Therefore, our scenario provides a novel potential source for the observed anisotropic distribution of HVSs. Nuclear spiral arms may also be important for accelerating the coalescence of binary SMBHs and for supplying nuclear star clusters with stars and gas.

  7. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    International Nuclear Information System (INIS)

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor

    2011-01-01

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 ± 0.44 mm (Mean ± STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 ± 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

  8. Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Dehghan, Ehsan; Moradi, Mehdi; Wen, Xu; French, Danny; Lobo, Julio; Morris, W. James; Salcudean, Septimiu E.; Fichtinger, Gabor [School of Computing, Queen' s University, Kingston, Ontario K7L-3N6 (Canada); Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T-1Z4 (Canada); Vancouver Cancer Centre, Vancouver, British Columbia V5Z-1E6 (Canada); Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, British Columbia V6T-1Z4 (Canada); School of Computing, Queen' s University, Kingston, Ontario K7L-3N6 (Canada)

    2011-10-15

    Purpose: Accurate localization of prostate implants from several C-arm images is necessary for ultrasound-fluoroscopy fusion and intraoperative dosimetry. The authors propose a computational motion compensation method for tomosynthesis-based reconstruction that enables 3D localization of prostate implants from C-arm images despite C-arm oscillation and sagging. Methods: Five C-arm images are captured by rotating the C-arm around its primary axis, while measuring its rotation angle using a protractor or the C-arm joint encoder. The C-arm images are processed to obtain binary seed-only images from which a volume of interest is reconstructed. The motion compensation algorithm, iteratively, compensates for 2D translational motion of the C-arm by maximizing the number of voxels that project on a seed projection in all of the images. This obviates the need for C-arm full pose tracking traditionally implemented using radio-opaque fiducials or external trackers. The proposed reconstruction method is tested in simulations, in a phantom study and on ten patient data sets. Results: In a phantom implanted with 136 dummy seeds, the seed detection rate was 100% with a localization error of 0.86 {+-} 0.44 mm (Mean {+-} STD) compared to CT. For patient data sets, a detection rate of 99.5% was achieved in approximately 1 min per patient. The reconstruction results for patient data sets were compared against an available matching-based reconstruction method and showed relative localization difference of 0.5 {+-} 0.4 mm. Conclusions: The motion compensation method can successfully compensate for large C-arm motion without using radio-opaque fiducial or external trackers. Considering the efficacy of the algorithm, its successful reconstruction rate and low computational burden, the algorithm is feasible for clinical use.

  9. STRUCTURED MOLECULAR GAS REVEALS GALACTIC SPIRAL ARMS

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Tsuyoshi [Joint ALMA Office, Alonso de Cordova 3107, Vitacura, Santiago 763-0355 (Chile); Hasegawa, Tetsuo [NAOJ Chile Observatory, Joaquin Montero 3000 Oficina 702, Vitacura, Santiago 763-0409 (Chile); Koda, Jin, E-mail: sawada.tsuyoshi@nao.ac.jp [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794-3800 (United States)

    2012-11-01

    We explore the development of structures in molecular gas in the Milky Way by applying the analysis of the brightness distribution function and the brightness distribution index (BDI) in the archival data from the Boston University-Five College Radio Astronomy Observatory {sup 13}CO J = 1-0 Galactic Ring Survey. The BDI measures the fractional contribution of spatially confined bright molecular emission over faint emission extended over large areas. This relative quantity is largely independent of the amount of molecular gas and of any conventional, pre-conceived structures, such as cores, clumps, or giant molecular clouds. The structured molecular gas traced by higher BDI is located continuously along the spiral arms in the Milky Way in the longitude-velocity diagram. This clearly indicates that molecular gas changes its structure as it flows through the spiral arms. Although the high-BDI gas generally coincides with H II regions, there is also some high-BDI gas with no/little signature of ongoing star formation. These results support a possible evolutionary sequence in which unstructured, diffuse gas transforms itself into a structured state on encountering the spiral arms, followed by star formation and an eventual return to the unstructured state after the spiral arm passage.

  10. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  11. Small-angle X-ray Solution Scattering Study of the Multi-aminoacyl-tRNA Synthetase Complex Reveals an Elongated and Multi-armed particle*

    Science.gov (United States)

    Dias, José; Renault, Louis; Pérez, Javier; Mirande, Marc

    2013-01-01

    In animal cells, nine aminoacyl-tRNA synthetases are associated with the three auxiliary proteins p18, p38, and p43 to form a stable and conserved large multi-aminoacyl-tRNA synthetase complex (MARS), whose molecular mass has been proposed to be between 1.0 and 1.5 MDa. The complex acts as a molecular hub for coordinating protein synthesis and diverse regulatory signal pathways. Electron microscopy studies defined its low resolution molecular envelope as an overall rather compact, asymmetric triangular shape. Here, we have analyzed the composition and homogeneity of the native mammalian MARS isolated from rabbit liver and characterized its overall internal structure, size, and shape at low resolution by hydrodynamic methods and small-angle x-ray scattering in solution. Our data reveal that the MARS exhibits a much more elongated and multi-armed shape than expected from previous reports. The hydrodynamic and structural features of the MARS are large compared with other supramolecular assemblies involved in translation, including ribosome. The large dimensions and non-compact structural organization of MARS favor a large protein surface accessibility for all its components. This may be essential to allow structural rearrangements between the catalytic and cis-acting tRNA binding domains of the synthetases required for binding the bulky tRNA substrates. This non-compact architecture may also contribute to the spatiotemporal controlled release of some of its components, which participate in non-canonical functions after dissociation from the complex. PMID:23836901

  12. Tracked Robot with Blade Arms to Enhance Crawling Capability

    OpenAIRE

    Jhu-Wei Ji; Fa-Shian Chang; Lih-Tyng Hwang; Chih-Feng Liu; Jeng-Nan Lee; Shun-Min Wang; Kai-Yi Cho

    2016-01-01

    This paper presents a tracked robot with blade arms powered to assist movement in difficult environments. As a result, the tracked robot is able to pass a ramp or climb stairs. The main feature is a pair of blade arms on both sides of the vehicle body working in collaboration with previously validated transformable track system. When the robot encounters an obstacle in a terrain, it enlists the blade arms with power to overcome the obstacle. In disaster areas, there usually will be terrains t...

  13. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  14. C-arm CT for planning and guidance of extrahepatic embolizations

    International Nuclear Information System (INIS)

    Wacker, F.K.; Meissner, O.A.; Meyer, B.C.

    2009-01-01

    Interventional radiological vascular embolizations are complex procedures that require exact imaging of the target region to facilitate safe and effective treatment. The purpose of this paper is to present the technique and feasibility of flat detector C-arm computed tomography (C-arm CT) for control and guidance of extrahepatic abdominal embolization procedures. C-arm CT images can provide important information on both vascular and cross-sectional anatomy of the target region, help in determining therapy endpoints and provide follow-up during and immediately after the abdominal interventions.The cases presented demonstrate that C-arm CT images are beneficial for abdominal embolization procedures and facilitate precise treatment. (orig.) [de

  15. Co-Simulation Control of Robot Arm Dynamics in ADAMS and MATLAB

    OpenAIRE

    Luo Haitao; Liu Yuwang; Chen Zhengcang; Leng Yuquan

    2013-01-01

    The main objective of this study is how to quickly establish the virtual prototyping model of robot arm system and effectively solve trajectory tracking control for a given signal. Taking the 2-DOF robot arm as an example, a co-simulation control method is introduced to research multi-body dynamics. Using Newton-Euler and Lagrange method, respectively establish the dynamics model of robot arm and verify the correctness of equations. Firstly, the physical model of robot arm was built by PROE a...

  16. ARM Cloud Radar Simulator Package for Global Climate Models Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yuying [North Carolina State Univ., Raleigh, NC (United States); Xie, Shaocheng [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-01

    It has been challenging to directly compare U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility ground-based cloud radar measurements with climate model output because of limitations or features of the observing processes and the spatial gap between model and the single-point measurements. To facilitate the use of ARM radar data in numerical models, an ARM cloud radar simulator was developed to converts model data into pseudo-ARM cloud radar observations that mimic the instrument view of a narrow atmospheric column (as compared to a large global climate model [GCM] grid-cell), thus allowing meaningful comparison between model output and ARM cloud observations. The ARM cloud radar simulator value-added product (VAP) was developed based on the CloudSat simulator contained in the community satellite simulator package, the Cloud Feedback Model Intercomparison Project (CFMIP) Observation Simulator Package (COSP) (Bodas-Salcedo et al., 2011), which has been widely used in climate model evaluation with satellite data (Klein et al., 2013, Zhang et al., 2010). The essential part of the CloudSat simulator is the QuickBeam radar simulator that is used to produce CloudSat-like radar reflectivity, but is capable of simulating reflectivity for other radars (Marchand et al., 2009; Haynes et al., 2007). Adapting QuickBeam to the ARM cloud radar simulator within COSP required two primary changes: one was to set the frequency to 35 GHz for the ARM Ka-band cloud radar, as opposed to 94 GHz used for the CloudSat W-band radar, and the second was to invert the view from the ground to space so as to attenuate the beam correctly. In addition, the ARM cloud radar simulator uses a finer vertical resolution (100 m compared to 500 m for CloudSat) to resolve the more detailed structure of clouds captured by the ARM radars. The ARM simulator has been developed following the COSP workflow (Figure 1) and using the capabilities available in COSP

  17. Rock Moved by Mars Lander Arm

    Science.gov (United States)

    2008-01-01

    The robotic arm on NASA's Phoenix Mars Lander slid a rock out of the way during the mission's 117th Martian day (Sept. 22, 2008) to gain access to soil that had been underneath the rock.The lander's Surface Stereo Imager took the two images for this stereo view later the same day, showing the rock, called 'Headless,' after the arm pushed it about 40 centimeters (16 inches) from its previous location. 'The rock ended up exactly where we intended it to,' said Matt Robinson of NASA's Jet Propulsion Laboratory, robotic arm flight software lead for the Phoenix team. The arm had enlarged the trench near Headless two days earlier in preparation for sliding the rock into the trench. The trench was dug to about 3 centimeters (1.2 inches) deep. The ground surface between the rock's prior position and the lip of the trench had a slope of about 3 degrees downward toward the trench. Headless is about the size and shape of a VHS videotape. The Phoenix science team sought to move the rock in order to study the soil and the depth to subsurface ice underneath where the rock had been. This image was taken at about 12:30 p.m., local solar time on Mars. The view is to the north northeast of the lander. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by JPL, Pasadena, Calif. Spacecraft development was by Lockheed Martin Space Systems, Denver.

  18. 77 FR 42707 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-07-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-35] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Force (DAY) [[Page 42709

  19. ARMED CONFLICT IN CHECHNYA IN EUROPEAN (NON ENGLISH HISTORIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Николай Николаевич Малишевский

    2016-12-01

    Full Text Available The article deals with the problems of historiography of the armed conflict in the Chechen Republic. The activephase of themilitary operationsofthe armed conflictin Chechnyawas completedin2001. At that timehistorians, analysts andjournalists created awide range of theoretical worksconcerningthe conflict.Inthese publications there were discussed a number of commonfeaturesofthe use ofbasicresources. The degree ofaccessibilityof the sourceswhichfocus onthe descriptionof the conflictand itssocio-political assessment is of great importance for researchersand their objectives. The author analyzes Western (European historiography of the armed conflict in the Chechen Republic. It considers the publications and specialized monographs of European (French, German and Polish authors on the subjects under research. There areput forward the ideas of the consequences of the armed conflict in the Chechen Republic, articulated in the works of European researchers.For the first time within the study of the Western historiography of the war in Chechnya the author analyzes the main blocks of the supposed and factual consequences of the conflict for both the Russian and Chechen sides. The European historiography, dedicated tothe armed conflictin Chechnya, is just being developedand thestate ofitsdocumentarycomplexis characterized bya number ofqualitative changes.

  20. New Horizons and New Strategies in Arms Control

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J. editor

    1998-12-04

    In the last ten years, since the break-up of the Soviet Union, remarkable progress in arms control and disarmament has occurred. The Nuclear Non-Proliferation Treaty (NPT), the completion of the Comprehensive Test Ban Treaty (CTBT), and the Chemical Weapons Treaty (CWC) are indicative of the great strides made in the non- proliferation arena. Simultaneously, the Intermediate Nuclear Forces Treaty (INF), the Conventional Forces Treaty in Europe (CFE), and the Strategic Arms Reduction Treaties (START), all associated with US-Soviet Union (now Russia) relations have assisted in redefining European relations and the security landscape. Finally, it now appears that progress is in the offing in developing enhanced compliance measures for the Biological and Toxin Weapons Convention (BTWC). In sum, all of these achievements have set the stage for the next round of arms control activities, which may lead to a much broader, and perhaps more diffused multilateral agenda. In this new and somewhat unpredictable international setting, arms control and disarmament issues will require solutions that are both more creative and innovative than heretofore.

  1. Arm coordination in octopus crawling involves unique motor control strategies.

    Science.gov (United States)

    Levy, Guy; Flash, Tamar; Hochner, Binyamin

    2015-05-04

    To cope with the exceptional computational complexity that is involved in the control of its hyper-redundant arms [1], the octopus has adopted unique motor control strategies in which the central brain activates rather autonomous motor programs in the elaborated peripheral nervous system of the arms [2, 3]. How octopuses coordinate their eight long and flexible arms in locomotion is still unknown. Here, we present the first detailed kinematic analysis of octopus arm coordination in crawling. The results are surprising in several respects: (1) despite its bilaterally symmetrical body, the octopus can crawl in any direction relative to its body orientation; (2) body and crawling orientation are monotonically and independently controlled; and (3) contrasting known animal locomotion, octopus crawling lacks any apparent rhythmical patterns in limb coordination, suggesting a unique non-rhythmical output of the octopus central controller. We show that this uncommon maneuverability is derived from the radial symmetry of the arms around the body and the simple pushing-by-elongation mechanism by which the arms create the crawling thrust. These two together enable a mechanism whereby the central controller chooses in a moment-to-moment fashion which arms to recruit for pushing the body in an instantaneous direction. Our findings suggest that the soft molluscan body has affected in an embodied way [4, 5] the emergence of the adaptive motor behavior of the octopus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Initial explorations of ARM processors for scientific computing

    International Nuclear Information System (INIS)

    Abdurachmanov, David; Elmer, Peter; Eulisse, Giulio; Muzaffar, Shahzad

    2014-01-01

    Power efficiency is becoming an ever more important metric for both high performance and high throughput computing. Over the course of next decade it is expected that flops/watt will be a major driver for the evolution of computer architecture. Servers with large numbers of ARM processors, already ubiquitous in mobile computing, are a promising alternative to traditional x86-64 computing. We present the results of our initial investigations into the use of ARM processors for scientific computing applications. In particular we report the results from our work with a current generation ARMv7 development board to explore ARM-specific issues regarding the software development environment, operating system, performance benchmarks and issues for porting High Energy Physics software

  3. Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model.

    Science.gov (United States)

    Veulemans, Verena; Mollus, Sabine; Saalbach, Axel; Pietsch, Max; Hellhammer, Katharina; Zeus, Tobias; Westenfeld, Ralf; Weese, Jürgen; Kelm, Malte; Balzer, Jan

    2016-10-26

    To investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR). Rotational C-arm CT (RCT) under rapid ventricular pacing was performed in 57 consecutive patients with severe aortic stenosis as part of the pre-procedural cardiac catheterization. With prototype software each RCT data set was segmented using a 3D heart model. From that the line of perpendicularity curve was obtained that generates a perpendicular view of the aortic annulus according to the right-cusp rule. To evaluate the accuracy of a model-based overlay we compared model- and expert-derived aortic root diameters. For all 57 patients in the RCT cohort diameter measurements were obtained from two independent operators and were compared to the model-based measurements. The inter-observer variability was measured to be in the range of 0°-12.96° of angular C-arm displacement for two independent operators. The model-to-operator agreement was 0°-13.82°. The model-based and expert measurements of aortic root diameters evaluated at the aortic annulus ( r = 0.79, P optimal C-arm configuration, potentially simplifying current clinical workflows before and during TAVR.

  4. Light Duty Utility Arm computer software configuration management plan

    International Nuclear Information System (INIS)

    Philipp, B.L.

    1998-01-01

    This plan describes the configuration management for the Light Duty Utility Arm robotic manipulation arm control software. It identifies the requirement, associated documents, and the software control methodology. The Light Duty Utility Ann (LDUA) System is a multi-axis robotic manipulator arm and deployment vehicle, used to perform surveillance and characterization operations in support of remediation of defense nuclear wastes currently stored in the Hanford Underground Storage Tanks (USTs) through the available 30.5 cm (12 in.) risers. This plan describes the configuration management of the LDUA software

  5. Multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Luo-Luo, E-mail: jiangluoluo@gmail.com [College of Physics and Electronic Information Engineering, Wenzhou University, Wenzhou 325035 (China); College of Physics and Technology, Guangxi Normal University, Guilin, Guangxi 541004 (China); Wang, Wen-Xu [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States); Department of Physics, Beijing Normal University, Beijing 100875 (China); Lai, Ying-Cheng [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States); Department of Physics, Arizona State University, Tempe, AZ 85287 (United States); Ni, Xuan [School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 (United States)

    2012-07-09

    We study the formation of multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games with mobile individuals. We discover a set of seed distributions of species, which is able to produce multi-armed spirals and multi-pairs antispirals with a finite number of arms and pairs based on stochastic processes. The joint spiral waves are also predicted by a theoretical model based on partial differential equations associated with specific initial conditions. The spatial entropy of patterns is introduced to differentiate the multi-armed spirals and multi-pairs antispirals. For the given mobility, the spatial entropy of multi-armed spirals is higher than that of single armed spirals. The stability of the waves is explored with respect to individual mobility. Particularly, we find that both two armed spirals and one pair antispirals transform to the single armed spirals. Furthermore, multi-armed spirals and multi-pairs antispirals are relatively stable for intermediate mobility. The joint spirals with lower numbers of arms and pairs are relatively more stable than those with higher numbers of arms and pairs. In addition, comparing to large amount of previous work, we employ the no flux boundary conditions which enables quantitative studies of pattern formation and stability in the system of stochastic interactions in the absence of excitable media. -- Highlights: ► Multi-armed spirals and multi-pairs antispirals are observed. ► Patterns are predicted by computer simulations and partial differential equations. ► The spatial entropy of patterns is introduced. ► Patterns are relatively stable for intermediate mobility. ► The joint spirals with lower numbers of arms and pairs are relatively more stable.

  6. Multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games

    International Nuclear Information System (INIS)

    Jiang, Luo-Luo; Wang, Wen-Xu; Lai, Ying-Cheng; Ni, Xuan

    2012-01-01

    We study the formation of multi-armed spirals and multi-pairs antispirals in spatial rock–paper–scissors games with mobile individuals. We discover a set of seed distributions of species, which is able to produce multi-armed spirals and multi-pairs antispirals with a finite number of arms and pairs based on stochastic processes. The joint spiral waves are also predicted by a theoretical model based on partial differential equations associated with specific initial conditions. The spatial entropy of patterns is introduced to differentiate the multi-armed spirals and multi-pairs antispirals. For the given mobility, the spatial entropy of multi-armed spirals is higher than that of single armed spirals. The stability of the waves is explored with respect to individual mobility. Particularly, we find that both two armed spirals and one pair antispirals transform to the single armed spirals. Furthermore, multi-armed spirals and multi-pairs antispirals are relatively stable for intermediate mobility. The joint spirals with lower numbers of arms and pairs are relatively more stable than those with higher numbers of arms and pairs. In addition, comparing to large amount of previous work, we employ the no flux boundary conditions which enables quantitative studies of pattern formation and stability in the system of stochastic interactions in the absence of excitable media. -- Highlights: ► Multi-armed spirals and multi-pairs antispirals are observed. ► Patterns are predicted by computer simulations and partial differential equations. ► The spatial entropy of patterns is introduced. ► Patterns are relatively stable for intermediate mobility. ► The joint spirals with lower numbers of arms and pairs are relatively more stable.

  7. EU Armed Forces' Use of Social Media in Areas of Deployment

    OpenAIRE

    Hellman, Maria; Olsson, Eva-Karin; Wagnsson, Charlotte

    2016-01-01

    The advent of social media can be seen both as a risk and an opportunity by armed forces. Previous research has primarily examined whether or not the use of social media endangers or strengthens armed forces’ strategic narrative. We examine armed forces’ perceptions of risks and opportunities on a broad basis, with a particular focus on areas of deployment. The article is based on a survey of perceptions of social media amongst the armed forces of EU member states, thus adding to previous res...

  8. Differences Between Right and Left Arm Blood Pressures in the Elderly

    OpenAIRE

    Hashimoto, Fred; Hunt, William C.; Hardy, Linda

    1984-01-01

    Recommendations vary on whether blood pressures should be measured in the right or in the left arm because no frequency distributions for a pressure difference between the arms exist. We took a total of 12 blood pressure determinations in both arms of 174 elderly persons and analyzed the data by a least-squares components of variance method. The mean difference between the arms (right minus left) was 0.93 mm of mercury for systole and 0.70 mm of mercury for diastole. For systole the proportio...

  9. European Union's Arms Control Regime and Arms Exports to China: Background and Legal Analysis

    National Research Council Canada - National Science Library

    Grimmett, Richard F; Papademetriou, Theresa

    2005-01-01

    In recent months, discussions have been held within the European Union (EU) on the question of lifting the embargo on arms exports to the People's Republic of China that was imposed on China on June 27, 1989...

  10. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  11. Hand-Arm vibration assessment among tiller operator

    Directory of Open Access Journals (Sweden)

    P. Nassiri

    2013-08-01

    Result: Results of the present study indicated that in all measured situations, exposure to hand arm vibration was higher than the standard limit suggested by Iranian occupational health committee and there was risk of vibration-induced disorders. The maximum exposure to vibration is in plowing ground. Exposure to hand arm vibration in three modes of plowing, transmission and natural, were respectively 16.95, 14.16 and 8.65 meters per second squared. Additionally, in all situations, vibration exposure was highest in the X-axis in comparison with Z- and Y-axes. .Conclusion: This study emphasizes on the need to provide intervention and controlling and managing strategies in order to eliminate or reduce vibration transmitted from tiller to operators hand and arm and also prevent to serious problems including neurovascular disorders, discomfort and white finger syndrome. Meanwhile, more studies are necessary to identify the sources of vibration on different models of tiller.

  12. Synthesis of Mikto-Arm Star Peptide Conjugates.

    Science.gov (United States)

    Koo, Jin Mo; Su, Hao; Lin, Yi-An; Cui, Honggang

    2018-01-01

    Mikto-arm star peptide conjugates are an emerging class of self-assembling peptide-based structural units that contain three or more auxiliary segments of different chemical compositions and/or functionalities. This group of molecules exhibit interesting self-assembly behavior in solution due to their chemically asymmetric topology. Here we describe the detailed procedure for synthesis of an ABC Mikto-arm star peptide conjugate in which two immiscible entities (a saturated hydrocarbon and a hydrophobic and lipophobic fluorocarbon) are conjugated onto a short β-sheet forming peptide sequence, GNNQQNY, derived from the Sup35 prion, through a lysine junction. Automated and manual Fmoc-solid phase synthesis techniques are used to synthesize the Mikto-arm star peptide conjugates, followed by HPLC purification. We envision that this set of protocols can afford a versatile platform to synthesize a new class of peptidic building units for diverse applications.

  13. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  14. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report: Updated in 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-15

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. ARM currently provides data and supporting metadata (information about the data or data quality) to its users through several sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, ARM relies on Instrument Mentors and the ARM Data Quality Office to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. This report is a continuation of the work presented by Campos and Sisterson (2015) and provides additional uncertainty information from instruments not available in their report. As before, a total measurement uncertainty has been calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). This study will not expand on methods for computing these uncertainties. As before, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available to the ARM community through the ARM Instrument Mentors and their ARM instrument handbooks. This study continues the first steps towards reporting ARM measurement uncertainty as: (1) identifying how the uncertainty of individual ARM measurements is currently expressed, (2) identifying a consistent approach to measurement uncertainty, and then (3) reclassifying ARM instrument measurement uncertainties in a common framework.

  15. Worldwide Report, Arms Control.

    Science.gov (United States)

    1986-02-04

    8217Unpredictable Consequences’ of SDI (Moscow PRAVDA, 7 Dec 85) 22 Moscow TV on ASTEC Meeting, Military Monopolies, SDI (Tomas Kolesnichenko; Moscow...planet. /8309 CSO: 5200/1228 22 JPRS-TAO86*014 4 February 1986 SDI AND SPACE ARMS MOSCOW TV ON ASTEC MEETING, MILITARY MONOPOLIES, SDI

  16. Virtual sine arm kinematic mount system

    International Nuclear Information System (INIS)

    Xu, Z.; Randall, K.J.

    1997-01-01

    A novel kinematic mount system for a vertical focusing mirror of the soft x-ray spectroscopy beamline at the Advanced Photon Source is described. The system contains three points in a horizontal plane. Each point consists of two horizontal linear precision stages, a spherical ball bearing, and a vertical precision stage. The horizontal linear stages are aligned orthogonally and are conjoined by a spherical ball bearing, supported by the vertical linear stage at each point. The position of each confined horizontal stage is controlled by a motorized micrometer head by spring-loading the flat tip of the micrometer head onto a tooling ball fixing on the carriage of the stage. A virtual sine arm is formed by tilting the upstream horizontal stage down and the two downstream horizontal stages up by a small angle. The fine pitch motion is achieved by adjusting the upstream stage. This supporting structure is extremely steady due to a relatively large span across the supporting points and yields extremely high resolution on the pitch motion. With a one degree tilt and a microstepping motor, the authors achieved a 0.4 nanoradian resolution on the mirror pitch motion

  17. Armed Helicopters: How the Army Fought Its Way into Attack Aviation

    Science.gov (United States)

    2015-04-01

    arm. It is included as an integral part of armies, corps and divisions; and as such must operate in close liaison with all arms.”5 The observation... launchers machine guns and mini-guns.57 There still seemed to be little if any systematic approach to the armed helicopter concept. The leadership

  18. Placement of the VenaTech LP Caval Filter in the Elderly: Feasibility and Clinical Benefits of Insertion Via the Arm

    International Nuclear Information System (INIS)

    Le Blanche, Alain F.; Pautas, Eric; Gouin, Isabelle; Baguees, Audrey; Piette, Francois; Chaibi, Pascal

    2005-01-01

    Purpose. To evaluate routine use of access sites in the arm for percutaneous caval filter placement (PCFP) in elderly patients. Neck arthritis, patient anxiety, access site thrombosis or fecal/urinary incontinence complicating jugular or femoral access may require alternative access sites in this population. Methods. Access via the right arm was chosen for PCFP (VenaTech LP). The indication for PCFP was deep vein thrombosis, a history of pulmonary embolism, and a contraindication to anticoagulant therapy. Ultrasound-guided puncture was performed after diameter measurement of the arm veins (O AV ). The filter was inserted with standard imaging procedures. Procedural difficulty was graded and compared with O AV and the angle from the arm vein to the superior vena cava (α AV/SVC ). Results. Over 2 years, 16 patients (14 women, 2 men) with an average age of 90 years (range 79-97 years) were included in the study. The average O AV value of the basilic or brachial veins was 4.2 mm (range 3.0-5.1 mm). The minimal O AV for successful access was determined after the first 15 patients. No hematoma occurred at the puncture sites. The average α AV/SVC value was 62 deg. (range 29 deg. - 90 deg.). Arm access was possible in 12 of 16 patients (75%) with O AV ≥ 3.5 mm and α AV/SVC ≥ 29 deg. Every procedure via the arm was graded 'easy' by the operator, regardless of angulation values. Femoral access was used in one case due to the impossibility of traversing the heart (patient no. 2), and jugular access was used in 3 of 16 (19%) patients due to puncture failure (patient no. 4), small O AV (3 mm) (patient no. 6), and stenosis of the distal right subclavian vein (patient no.16), respectively. Conclusion. PCFP via the arm can be routinely accomplished in patients older than 75 years, provided O AV ≥ 3.5 mm, and α AV/SVC ≥ 29 deg

  19. Light duty utility arm deployment in Hanford tank T-106

    International Nuclear Information System (INIS)

    Kiebel, G.R.

    1997-07-01

    An existing gap in the technology for the remediation of underground waste storage tanks filled by the Light Duty Utility Arm (LDUA) System. On September 27 and 30, 1996, the LDUA System was deployed in underground storage tank T-106 at Hanford. The system performed successfully, satisfying all objectives of the in-tank operational test (hot test); performing close-up video inspection of features of tank dome, risers, and wall; and grasping and repositioning in-tank debris. The successful completion of hot testing at Hanford means that areas of tank structure and waste surface that were previously inaccessible are now within reach of remote tools for inspection, waste analysis, and small-scale retrieval. The LDUA System has become a new addition to the arsenal of technologies being applied to solve tank waste remediation challenges

  20. Light duty utility arm deployment in Hanford tank T-106

    Energy Technology Data Exchange (ETDEWEB)

    Kiebel, G.R.

    1997-07-01

    An existing gap in the technology for the remediation of underground waste storage tanks filled by the Light Duty Utility Arm (LDUA) System. On September 27 and 30, 1996, the LDUA System was deployed in underground storage tank T-106 at Hanford. The system performed successfully, satisfying all objectives of the in-tank operational test (hot test); performing close-up video inspection of features of tank dome, risers, and wall; and grasping and repositioning in-tank debris. The successful completion of hot testing at Hanford means that areas of tank structure and waste surface that were previously inaccessible are now within reach of remote tools for inspection, waste analysis, and small-scale retrieval. The LDUA System has become a new addition to the arsenal of technologies being applied to solve tank waste remediation challenges.

  1. Worldwide Report, Arms Control

    Science.gov (United States)

    1986-02-28

    NACHRICHTEN , 18 Oct 85) 39 Presummit Polish Reporting on SDI Issues (Warsaw RZECZPOSPOLITA, 19-20 Oct 85; Warsaw ZYCIE WARSZAWY, 15 Oct 85) 42...28 February 1986 SDI AND SPACE ARMS MEETING REVEALS SOME SUPPORT FOR EUREKA LINK TO MILITARY Puesseldbrf VDI NACHRICHTEN in German 18 Oct 85 p 10

  2. Arms Trafficking and Colombia

    Science.gov (United States)

    2003-01-01

    chronology of the intensification of violence in the area, see Noche Y Niebla: Panorama De Derechos Humanos Y Violencia Politica En Colombia, Bogotá...Arms, London, UK: Zed Books, 2000, pp. 155–178. Noche Y Niebla: Panorama De Derechos Humanos Y Violencia Politica En Colombia, Bogotá: Cinep & Justicia

  3. Regenerator cross arm seal assembly

    Science.gov (United States)

    Jackman, Anthony V.

    1988-01-01

    A seal assembly for disposition between a cross arm on a gas turbine engine block and a regenerator disc, the seal assembly including a platform coextensive with the cross arm, a seal and wear layer sealingly and slidingly engaging the regenerator disc, a porous and compliant support layer between the platform and the seal and wear layer porous enough to permit flow of cooling air therethrough and compliant to accommodate relative thermal growth and distortion, a dike between the seal and wear layer and the platform for preventing cross flow through the support layer between engine exhaust and pressurized air passages, and air diversion passages for directing unregenerated pressurized air through the support layer to cool the seal and wear layer and then back into the flow of regenerated pressurized air.

  4. The Accountability of Armed Groups under Human Rights Law

    NARCIS (Netherlands)

    Fortin, K.M.A.

    2015-01-01

    The starting point for this NWOI funded Ph.D. research is the observation that although UN accountability mechanisms are increasingly holding armed groups ‘accountable’ under human rights law, the legal basis for the responsibility of armed groups under human rights law remains controversial

  5. Inverse kinematics of OWI-535 robotic arm

    OpenAIRE

    DEBENEC, PRIMOŽ

    2015-01-01

    The thesis aims to calculate the inverse kinematics for the OWI-535 robotic arm. The calculation of the inverse kinematics determines the joint parameters that provide the right pose of the end effector. The pose consists of the position and orientation, however, we will focus only on the second one. Due to arm limitations, we have created our own type of the calculation of the inverse kinematics. At first we have derived it only theoretically, and then we have transferred the derivation into...

  6. Animals and the law of armed conflict

    OpenAIRE

    Roscini, M.

    2017-01-01

    The main purposes of this article are to assess whether the existing rules of the law of armed conflict provide adequate protection to animals and to highlight the fault lines in the law. The article distinguishes the general provisions of the law of armed conflict, i.e. those that were not adopted with specific regard to animals but the application of which might restrict the killing and injuring of animals, from the provisions that specifically provide protection to animals. The analysis es...

  7. Unequal arm space-borne gravitational wave detectors

    International Nuclear Information System (INIS)

    Larson, Shane L.; Hellings, Ronald W.; Hiscock, William A.

    2002-01-01

    Unlike ground-based interferometric gravitational wave detectors, large space-based systems will not be rigid structures. When the end stations of the laser interferometer are freely flying spacecraft, the armlengths will change due to variations in the spacecraft positions along their orbital trajectories, so the precise equality of the arms that is required in a laboratory interferometer to cancel laser phase noise is not possible. However, using a method discovered by Tinto and Armstrong, a signal can be constructed in which laser phase noise exactly cancels out, even in an unequal arm interferometer. We examine the case where the ratio of the armlengths is a variable parameter, and compute the averaged gravitational wave transfer function as a function of that parameter. Example sensitivity curve calculations are presented for the expected design parameters of the proposed LISA interferometer, comparing it to a similar instrument with one arm shortened by a factor of 100, showing how the ratio of the armlengths will affect the overall sensitivity of the instrument

  8. Processing ARM VAP data on an AWS cluster

    Science.gov (United States)

    Martin, T.; Macduff, M.; Shippert, T.

    2017-12-01

    The Atmospheric Radiation Measurement (ARM) Data Management Facility (DMF) manages over 18,000 processes and 1.3 TB of data each day. This includes many Value Added Products (VAPs) that make use of multiple instruments to produce the derived products that are scientifically relevant. A thermodynamic and cloud profile VAP is being developed to provide input to the ARM Large-eddy simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) project (https://www.arm.gov/capabilities/vaps/lasso-122) . This algorithm is CPU intensive and the processing requirements exceeded the available DMF computing capacity. Amazon Web Service (AWS) along with CfnCluster was investigated to see how it would perform. This cluster environment is cost effective and scales dynamically based on demand. We were able to take advantage of autoscaling which allowed the cluster to grow and shrink based on the size of the processing queue. We also were able to take advantage of the Amazon Web Services spot market to further reduce the cost. Our test was very successful and found that cloud resources can be used to efficiently and effectively process time series data. This poster will present the resources and methodology used to successfully run the algorithm.

  9. 76 FR 17111 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-03-28

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-10] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  10. 76 FR 37071 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-06-24

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-03] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  11. 76 FR 37075 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-06-24

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-77] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  12. 76 FR 43659 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-07-21

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-28] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  13. 76 FR 27026 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-05-10

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-13] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  14. 76 FR 37078 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-06-24

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-68] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  15. 77 FR 60384 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-54] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This is...

  16. 76 FR 29212 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-05-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-75] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  17. 75 FR 76418 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-65] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  18. 75 FR 76415 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-72] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  19. 75 FR 74011 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-11-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-24] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  20. 75 FR 76412 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-69] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  1. 77 FR 60391 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-32] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This is...

  2. 75 FR 74014 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-11-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-49] 36(b)(1) Arms Sales Notification AGENCY: Department of Defense, Defense Security Cooperation Agency. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  3. 76 FR 27022 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-05-10

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-12] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  4. 77 FR 60387 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-26] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This is...

  5. 75 FR 76408 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-12-08

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-73] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, Department of Defense. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...

  6. Affine pairings on ARM

    NARCIS (Netherlands)

    Acar, T.; Lauter, K.; Naehrig, M.; Shumow, D.; Abdalla, M.; Lange, T.

    2013-01-01

    We report on relative performance numbers for affine and projective pairings on a dual-core Cortex A9 ARM processor. Using a fast inversion in the base field and doing inversion in extension fields by using the norm map to reduce to inversions in smaller fields, we find a very low ratio of

  7. Science Plan for the Atmospheric Radiation Measurement Program (ARM)

    International Nuclear Information System (INIS)

    1996-02-01

    The purpose of this Atmospheric Radiation Measurement (ARM) Science Plan is to articulate the scientific issues driving the ARM Program, and to relate them to DOE's programmatic objectives for ARM, based on the experience and scientific progress gained over the past five years. ARM programmatic objectives are to: (1) Relate observed radiative fluxes and radiances in the atmosphere, spectrally resolved and as a function of position and time, to the temperature and composition of the atmosphere, specifically including water vapor and clouds, and to surface properties, and sample sufficient variety of situations so as to span a wide range of climatologically relevant possibilities; (2) develop and test parameterizations that can be used to accurately predict the radiative properties and to model the radiative interactions involving water vapor and clouds within the atmosphere, with the objective of incorporating these parameterizations into general circulation models. The primary observational methods remote sending and other observations at the surface, particularly remote sensing of clouds, water vapor and aerosols

  8. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    Science.gov (United States)

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  9. Swiss Armed Forces Reform: Doctrinal and Organizational Challenges

    Science.gov (United States)

    2016-06-10

    conservatism and military innovation since this is where the essence of the Armed Forces resides. Sound doctrine and coherent organizations enables the...established doctrine can become part of the conservatism of the military institution. So the innovative capabilities of the military organization affect...in other fields. They challenged the inherent conservatism of the military institution. The down-sizing of the Armed Forces, the reduction of

  10. One arm exercise induces significant interarm diastolic blood pressure difference.

    Science.gov (United States)

    Hong, Dezhi; Wang, Jiwei; Su, Hai; Xu, Jingsong; Liu, Yanna; Peng, Qiang; Wang, Lijuan

    2011-06-01

    This study is designed to investigate the inducing effect of one arm exercise on interarm difference (IAD) in the blood pressure (BP). Fifty healthy young participants were included in the study. Three-minute exercises of the right arm elbow flexion and extension were performed. The bilateral brachial BP was simultaneously measured with two automatic BP measurement devices before (basic) and immediately 0, 5, 10, 15, 20, and 30 min after exercise. The absolute difference in the systolic BP (SBP) and diastolic BP (DBP) between the left and right BP of at least 10 mmHg was recognized as sIAD and dIAD. The baseline data of the SBP and DBP in left and right arms revealed no significant difference (SBP: 110 ± 10 vs. 111 ± 11 mmHg; DBP: 66 ± 8 vs. 66 ± 9 mmHg, both not significant). The prevalence of dIAD was 2% at the baseline. However, this prevalence increased to 80% at 0 min, as right arm exercise induced the right DBP decrease and left DBP increase, and then the prevalence decreased gradually within a 30-min recovery period. The prevalence of sIAD was zero at the baseline and the maximal prevalence was 8% during the 20-min postexercise period. One arm exercise can lead to a significant IAD in DBP. Any arm exercise should be avoided before BP measurement.

  11. Localization of age-related macular degeneration-associated ARMS2 in cytosol, not mitochondria

    Science.gov (United States)

    Wang, Gaofeng; Spencer, Kylee L.; Court, Brenda L.; Olson, Lana M.; Scott, William K.; Haines, Jonathan L.; Pericak-Vance, Margaret A.

    2010-01-01

    PURPOSE To analyze the relationship between ARMS2 and HTRA1 in the association with age-related macular degeneration (AMD) in an independent case-control dataset, and to investigate the subcellular localization of the ARMS2 protein in an in vitro system. METHOD Two SNPs in ARMS2 and HTRA1 were genotyped in 685 cases and 269 controls by Taqman Assay. Allelic association was tested by a χ2 test. A likelihood ratio test (LRT) of full vs. reduced models was utilized to analyze the interaction between ARMS2 and smoking and HTRA1 and smoking, after adjusting for CFH and age. Immunofluorescence and immunoblot were applied to localize ARMS2 in retinal epithelial ARPE-19 cells and COS7 cell transfected by ARMS2 constructs. RESULT Both significantly associated SNP rs10490924 and rs11200638 (P<0.0001) are in strong linkage disequilibrium (LD) (D′=0.97, r2=0.93) that generates virtually identical association test and odds ratios. In separate logistic regression models the interaction effect for both smoking with ARMS2 and with HTRA1 was not statistically significant. Immunofluorescence and immunoblot show that both endogenous and exogenous ARMS2 are mainly distributed in the cytosol, not the mitochondria. Comparing to wild type, ARMS2 A69S is more likely to be associated with cytoskeleton in COS7 cells. CONCLUSIONS The significant associations in ARMS2 and HTRA1 are with polymorphisms in strong LD that confer virtually identical risks, preventing differentiation at the statistical level. We found that ARMS2 was mainly distributed in the cytosol, not in mitochondrial outer membrane as previously reported, suggesting that ARMS2 may not confer risk to AMD through the mitochondrial pathway. PMID:19255159

  12. Arms Transfer and Confl ict in Africa The Role of China in Sudan ...

    African Journals Online (AJOL)

    The central argument of this article is that arms transfers from countries such as China to Sudan help sustain the armed confl ict in the country, as well as in the Horn of Africa region. This is because arms transfer increases the risk of ethnic disharmony, deeper militarisation, increased crime rate, multiplication of armed ...

  13. Feasibility Analysis of an All Volunteer Armed Force in Turkey

    National Research Council Canada - National Science Library

    Alanc, Ozgun U

    2007-01-01

    .... Accordingly, this project report provides a Draft versus All Volunteer Forces (AVF) analysis for the Turkish Armed Forces, by evaluating the feasibility and the desirability of an AVF for the Turkish Armed Forces...

  14. 75 FR 60424 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-09-30

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-28 and 10-30] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of two section 36(b)(1) arms sales notifications to...

  15. 75 FR 29998 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-05-28

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-22] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  16. 75 FR 23247 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-05-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-08] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  17. 75 FR 27314 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-05-14

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-19] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  18. 75 FR 11865 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2010-03-12

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal No. 10-12] 36(b)(1) Arms Sales Notification AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification to fulfill the...

  19. 76 FR 60455 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-71] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... support. (iv) Military Department: Army (UJT). (v) Prior Related Cases, if any: None. (vi) Sales...

  20. 77 FR 12037 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-11] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... support. (iv) Military Department: Navy (SAF). (v) Prior Related Cases, if any: None. (vi) Sales...

  1. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  2. Targeting and killing of glioblastoma with activated T cells armed with bispecific antibodies

    International Nuclear Information System (INIS)

    Zitron, Ian M; Thakur, Archana; Norkina, Oxana; Barger, Geoffrey R; Lum, Lawrence G; Mittal, Sandeep

    2013-01-01

    Since most glioblastomas express both wild-type EGFR and EGFRvIII as well as HER2/neu, they are excellent targets for activated T cells (ATC) armed with bispecific antibodies (BiAbs) that target EGFR and HER2. ATC were generated from PBMC activated for 14 days with anti-CD3 monoclonal antibody in the presence of interleukin-2 and armed with chemically heteroconjugated anti-CD3×anti-HER2/neu (HER2Bi) and/or anti-CD3×anti-EGFR (EGFRBi). HER2Bi- and/or EGFRBi-armed ATC were examined for in vitro cytotoxicity using MTT and 51 Cr-release assays against malignant glioma lines (U87MG, U118MG, and U251MG) and primary glioblastoma lines. EGFRBi-armed ATC killed up to 85% of U87, U118, and U251 targets at effector:target ratios (E:T) ranging from 1:1 to 25:1. Engagement of tumor by EGFRBi-armed ATC induced Th1 and Th2 cytokine secretion by armed ATC. HER2Bi-armed ATC exhibited comparable cytotoxicity against U118 and U251, but did not kill HER2-negative U87 cells. HER2Bi- or EGFRBi-armed ATC exhibited 50—80% cytotoxicity against four primary glioblastoma lines as well as a temozolomide (TMZ)-resistant variant of U251. Both CD133– and CD133+ subpopulations were killed by armed ATC. Targeting both HER2Bi and EGFRBi simultaneously showed enhanced efficacy than arming with a single BiAb. Armed ATC maintained effectiveness after irradiation and in the presence of TMZ at a therapeutic concentration and were capable of killing multiple targets. High-grade gliomas are suitable for specific targeting by armed ATC. These data, together with additional animal studies, may provide the preclinical support for the use of armed ATC as a valuable addition to current treatment regimens

  3. Naval trends in ASEAN: is there a new arms race?

    OpenAIRE

    Jones, Frank Curtis

    1995-01-01

    Global military spending is decreasing. However this trend does not apply to some regions of the world, specifically Southeast Asia. This thesis describes the ongoing naval arms buildup in this region and examines why it is occurring when the rest of the world is decreasing military spending. Next, this thesis asks if this arms build-up is dangerous. Unlike many other arms races around the world, the Southeast Asian build-up is not particularly dangerous because of the parallel development of...

  4. Patterns of motor activity in the isolated nerve cord of the octopus arm.

    Science.gov (United States)

    Gutfreund, Yoram; Matzner, Henry; Flash, Tamar; Hochner, Binyamin

    2006-12-01

    The extremely flexible octopus arm provides a unique opportunity for studying movement control in a highly redundant motor system. We describe a novel preparation that allows analysis of the peripheral nervous system of the octopus arm and its interaction with the muscular and mechanosensory elements of the arm's intrinsic muscular system. First we examined the synaptic responses in muscle fibers to identify the motor pathways from the axial nerve cord of the arm to the surrounding musculature. We show that the motor axons project to the muscles via nerve roots originating laterally from the arm nerve cord. The motor field of each nerve is limited to the region where the nerve enters the arm musculature. The same roots also carry afferent mechanosensory information from the intrinsic muscle to the axial nerve cord. Next, we characterized the pattern of activity generated in the dorsal roots by electrically stimulating the axial nerve cord. The evoked activity, although far reaching and long lasting, cannot alone account for the arm extension movements generated by similar electrical stimulation. The mismatch between patterns of activity in the isolated cord and in an intact arm may stem from the involvement of mechanosensory feedback in natural arm extension.

  5. Stereotypical reaching movements of the octopus involve both bend propagation and arm elongation.

    Science.gov (United States)

    Hanassy, S; Botvinnik, A; Flash, T; Hochner, B

    2015-05-13

    The bend propagation involved in the stereotypical reaching movement of the octopus arm has been extensively studied. While these studies have analyzed the kinematics of bend propagation along the arm during its extension, possible length changes have been ignored. Here, the elongation profiles of the reaching movements of Octopus vulgaris were assessed using three-dimensional reconstructions. The analysis revealed that, in addition to bend propagation, arm extension movements involve elongation of the proximal part of the arm, i.e., the section from the base of the arm to the propagating bend. The elongations are quite substantial and highly variable, ranging from an average strain along the arm of -0.12 (i.e. shortening) up to 1.8 at the end of the movement (0.57 ± 0.41, n = 64 movements, four animals). Less variability was discovered in an additional set of experiments on reaching movements (0.64 ± 0.28, n = 30 movements, two animals), where target and octopus positions were kept more stationary. Visual observation and subsequent kinematic analysis suggest that the reaching movements can be broadly segregated into two groups. The first group involves bend propagation beginning at the base of the arm and propagating towards the arm tip. In the second, the bend is formed or present more distally and reaching is achieved mainly by elongation and straightening of the segment proximal to the bend. Only in the second type of movements is elongation significantly positively correlated with the distance of the bend from the target. We suggest that reaching towards a target is generated by a combination of both propagation of a bend along the arm and arm elongation. These two motor primitives may be combined to create a broad spectrum of reaching movements. The dynamical model, which recapitulates the biomechanics of the octopus muscular hydrostatic arm, suggests that achieving the observed elongation requires an extremely low ratio of longitudinal to transverse muscle

  6. The effect of unilateral arm swing motion on lower extremity running mechanics associated with injury risk.

    Science.gov (United States)

    Agresta, Cristine; Ward, Christian R; Wright, W Geoffrey; Tucker, Carole A

    2018-06-01

    Many field sports involve equipment that restricts one or both arms from moving while running. Arm swing during running has been examined from a biomechanical and physiologic perspective but not from an injury perspective. Moreover, only bilateral arm swing suppression has been studied with respect to running. The purpose of this study was to determine the influence of running with one arm restrained on lower extremity mechanics associated with running or sport-related injury. Fifteen healthy participants ran at a self-selected speed with typical arm swing, with one arm restrained and with both arms restrained. Lower extremity kinematics and spatiotemporal measures were analysed for all arm swing conditions. Running with one arm restrained resulted in increased frontal plane knee and hip angles, decreased foot strike angle, and decreased centre of mass vertical displacement compared to typical arm swing or bilateral arm swing restriction. Stride length was decreased and step frequency increased when running with one or both arms restrained. Unilateral arm swing restriction induces changes in lower extremity kinematics that are not similar to running with bilateral arm swing restriction or typical arm swing motion. Running with one arm restrained increases frontal plane mechanics associated with risk of knee injury.

  7. The Asteroid Redirect Mission (ARM)

    Science.gov (United States)

    Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Mazanek, Dan; Reeves, David; Ticker, Ronald

    2016-07-01

    To achieve its long-term goal of sending humans to Mars, the National Aeronautics and Space Administration (NASA) plans to proceed in a series of incrementally more complex human spaceflight missions. Today, human flight experience extends only to Low-Earth Orbit (LEO), and should problems arise during a mission, the crew can return to Earth in a matter of minutes to hours. The next logical step for human spaceflight is to gain flight experience in the vicinity of the Moon. These cis-lunar missions provide a "proving ground" for the testing of systems and operations while still accommodating an emergency return path to the Earth that would last only several days. Cis-lunar mission experience will be essential for more ambitious human missions beyond the Earth-Moon system, which will require weeks, months, or even years of transit time. In addition, NASA has been given a Grand Challenge to find all asteroid threats to human populations and know what to do about them. Obtaining knowledge of asteroid physical properties combined with performing technology demonstrations for planetary defense provide much needed information to address the issue of future asteroid impacts on Earth. Hence the combined objectives of human exploration and planetary defense give a rationale for the Asteroid Re-direct Mission (ARM). Mission Description: NASA's ARM consists of two mission segments: 1) the Asteroid Redirect Robotic Mission (ARRM), the first robotic mission to visit a large (greater than ~100 m diameter) near-Earth asteroid (NEA), collect a multi-ton boulder from its surface along with regolith samples, demonstrate a planetary defense technique, and return the asteroidal material to a stable orbit around the Moon; and 2) the Asteroid Redirect Crewed Mission (ARCM), in which astronauts will take the Orion capsule to rendezvous and dock with the robotic vehicle, conduct multiple extravehicular activities to explore the boulder, and return to Earth with samples. NASA's proposed

  8. Dermal safety assessment of Arm & Hammer laundry products formulated for sensitive skin.

    Science.gov (United States)

    Frederick, Douglas M; Vorwerk, Linda; Gupta, Archana; Ghassemi, Annahita

    2017-09-01

    product (Arm & Hammer Free & Clear) and other nonirritant controls. In the Wrist Band Wear test, exposure to laundered fabrics under exaggerated conditions gave similar results for the test and control products, with no objective signs of skin irritation, and no self-reported persistent adverse sensory effects. Very mild, transient and isolated sensory effects were noted in daily diaries by a small proportion of subjects, and were similar for the test and control products. The Safety In-Use tests evaluated 4-week exposure to product and laundered fabrics under realistic use conditions. There were no clinically objective signs of skin irritation, and reports of transitory, mild sensory effects were minimal and similar for the test and controls. A comprehensive skin safety program on a lightly scented sensitive skin laundry formulation (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent) conducted among panels of self-assessed sensitive skin subjects demonstrated that the presence of a light fragrance did not adversely impact skin compatibility in any of the testing protocols when the product was compared to a similar product with no fragrance. The lightly fragranced product demonstrated overall skin compatibility and mildness when tested in a self-assessed sensitive skin population, and compared favorably to currently marketed sensitive skin products.

  9. 78 FR 62590 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-43] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii) Sensitivity of...

  10. 76 FR 43662 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-07-21

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-15] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Military Department: Navy (AAR) (v) Prior Related Cases, if any: None (vi) Sales Commission, Fee, etc...

  11. 75 FR 61440 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-10-05

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-47, 10-48, and 10-51] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of three section 36(b)(1) arms sales notifications...

  12. 77 FR 37884 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-06-25

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-19] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Department: Navy (LAN). (v) Prior Related Cases, if any: None. (vi) Sales Commission, Fee, etc., Paid...

  13. 78 FR 26324 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-05-06

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-20] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Gasoline). (v) Prior Related Cases, if any: Numerous cases dating back to 1995. (vi) Sales Commission, Fee...

  14. 75 FR 48646 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-08-11

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-27, 10-31 and 10-41] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION: Notice. SUMMARY: The Department of Defense is publishing the unclassified text of three section 36(b)(1) arms sales notifications...

  15. 78 FR 76114 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-12-16

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-66] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii) Sensitivity of Technology...

  16. 78 FR 42051 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-07-15

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-26] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... any: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii...

  17. 78 FR 62600 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-47] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed To Be Paid: None (vii) Sensitivity of...

  18. 77 FR 51780 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-08-27

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-42] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... support. (iv) Military Department: Air Force (QAZ). (v) Prior Related Cases, if any: None. (vi) Sales...

  19. 77 FR 70151 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-11-23

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-56] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: Army (UAK). (v) Prior Related Cases, if any: None. (vi) Sales Commission, Fee, etc., Paid, Offered, or...

  20. 77 FR 13564 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-03-07

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-53] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This..., if any: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii...

  1. 78 FR 62588 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-53] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii) Sensitivity of Technology...

  2. 75 FR 41820 - 36(b)(1) Arms Sales Notifications

    Science.gov (United States)

    2010-07-19

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 10-05, 10-11, 10-18, 10-21 and 10-29] 36(b)(1) Arms Sales Notifications AGENCY: Defense Security Cooperation Agency, DoD. ACTION...) arms sales notifications to fulfill the requirements of section 155 of Public Law 104-164, dated 21...

  3. 76 FR 60467 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-34] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: a Foreign Military Sales Order II (FMSO II) to provide funds for blanket order requisitions, under...

  4. 78 FR 69073 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-11-18

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-59] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Military Department: Air Force (QAH) (v) Prior Related Cases: None (vi) Sales Commission, Fee, etc., Paid...

  5. Rosoboroneksport: Arms Sales and the Structure of Russian Defense Industry

    National Research Council Canada - National Science Library

    Blank, Stephen J

    2007-01-01

    .... Arms sales thus have become the main source of its revenue until the present and will play a key role in Russia's ongoing attempt to regenerate its armed forces while winning friends and influence abroad...

  6. Arm circumference: its importance for dialysis patients in the obesity era.

    Science.gov (United States)

    Akpolat, Tekin; Kaya, Coşkun; Utaş, Cengiz; Arinsoy, Turgay; Taşkapan, Hülya; Erdem, Emre; Yilmaz, M Emin; Ataman, Rezzan; Bozfakioğlu, Semra; Özener, Çetin; Karayaylali, Ibrahim; Kazancioğlu, Rümeyza; Çamsari, Taner; Yavuz, Mahmut; Ersoy, Fevzi; Duman, Soner; Ateş, Kenan

    2013-08-01

    The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients. 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations. Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002). Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.

  7. Increasing cognitive load attenuates right arm swing in healthy human walking

    Science.gov (United States)

    Killeen, Tim; Easthope, Christopher S.; Filli, Linard; Lőrincz, Lilla; Schrafl-Altermatt, Miriam; Brugger, Peter; Linnebank, Michael; Curt, Armin; Zörner, Björn; Bolliger, Marc

    2017-01-01

    Human arm swing looks and feels highly automated, yet it is increasingly apparent that higher centres, including the cortex, are involved in many aspects of locomotor control. The addition of a cognitive task increases arm swing asymmetry during walking, but the characteristics and mechanism of this asymmetry are unclear. We hypothesized that this effect is lateralized and a Stroop word-colour naming task-primarily involving left hemisphere structures-would reduce right arm swing only. We recorded gait in 83 healthy subjects aged 18-80 walking normally on a treadmill and while performing a congruent and incongruent Stroop task. The primary measure of arm swing asymmetry-an index based on both three-dimensional wrist trajectories in which positive values indicate proportionally smaller movements on the right-increased significantly under dual-task conditions in those aged 40-59 and further still in the over-60s, driven by reduced right arm flexion. Right arm swing attenuation appears to be the norm in humans performing a locomotor-cognitive dual-task, confirming a prominent role of the brain in locomotor behaviour. Women under 60 are surprisingly resistant to this effect, revealing unexpected gender differences atop the hierarchical chain of locomotor control.

  8. Study on the Orion spiral arm structure by the statistical modelling method

    International Nuclear Information System (INIS)

    Basharina, T.S.; Pavlovskaya, E.D.; Filippova, A.A.

    1980-01-01

    A method of investigation of the spiral structure based on the statistical modelling methods is suggested. This method is used for the study of the Orion spiral arm. The maxima of density and the widths of the Orion arm in the direction of the areas considered for the longitude interval 55 deg - 187 deg are defined under the assumption of normal distribution of stars across the arm. The Sun is shown to be at the inner edge of the arm [ru

  9. Gender Integration and the Swedish Armed Forces

    DEFF Research Database (Denmark)

    Gustafsson, Daniel Marcus Sunil

    This paper discusses different gender aspects of the Swedish Armed Forces with specific references to sexual harassment and prostitution. By using the concept of Hegemonic Masculinity, sexual harassment of the women in the Swedish Armed Forces is explained in terms of a need of the men within...... the organisation to reinforce the notion of women as inferior and subordinate to men, whereby the external hegemony is believed to be restored. Likewise, male Swedish peacekeepers’ demand for prostitution during international peacekeeping missions is explained in terms of a need to confirm manhood and as homo...

  10. Neurobiology: motor control of flexible octopus arms.

    Science.gov (United States)

    Sumbre, Germán; Fiorito, Graziano; Flash, Tamar; Hochner, Binyamin

    2005-02-10

    Animals with rigid skeletons can rely on several mechanisms to simplify motor control--for example, they have skeletal joints that reduce the number of variables and degrees of freedom that need to be controlled. Here we show that when the octopus uses one of its long and highly flexible arms to transfer an object from one place to another, it employs a vertebrate-like strategy, temporarily reconfiguring its arm into a stiffened, articulated, quasi-jointed structure. This indicates that an articulated limb may provide an optimal solution for achieving precise, point-to-point movements.

  11. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger-arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3-DOF fingers are attached to the end-effector of a 6-DOF arm to configure a multi-finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi-finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini-max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi-finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  12. Re-usable low density polyethylene arm glove for puerperal ...

    African Journals Online (AJOL)

    Objective: To design a long arm glove that can be used within a puerperal uterus to prevent the health-care worker contracting HIV from an infected patient. The designed long arm glove should be cheap (affordable) and readily available in low resource centres and must have proven sterility assurance and tensile strength ...

  13. 78 FR 78939 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-12-27

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-68] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-$98M (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: N/A (vii) Sensitivity of...

  14. 77 FR 42709 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-07-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-24] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... Cases, if any: None (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None (vii...

  15. 78 FR 26326 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-05-06

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-09] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-20Feb08. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None. (vii) Sensitivity of...

  16. 76 FR 60459 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-19] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-$280 million-29Nov07. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None. (vii...

  17. A POSSIBLE EXTENSION OF THE SCUTUM-CENTAURUS ARM INTO THE OUTER SECOND QUADRANT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yan; Xu, Ye; Yang, Ji; Li, Fa-Cheng; Du, Xin-Yu; Zhang, Shao-Bo; Zhou, Xin, E-mail: yansun@pmo.ac.cn [Purple Mountain Observatory and Key Laboratory of Radio Astronomy, Chinese Academy of Sciences, Nanjing 210008 (China)

    2015-01-10

    Combining H I data from the Canadian Galactic Plane Survey and CO data from the Milky Way Imaging Scroll Painting project, we have identified a new segment of a spiral arm between Galactocentric radii of 15 and 19 kpc that apparently lies beyond the Outer Arm in the second Galactic quadrant. Over most of its length, the arm is 400-600 pc thick in z. The new arm appears to be the extension of the distant arm recently discovered by Dame and Thaddeus as well as the Scutum-Centaurus Arm into the outer second quadrant. Our current survey identified a total of 72 molecular clouds with masses on the order of 10{sup 2}-10{sup 4} M {sub ☉} that probably lie in the new arm. When all of the available data from the CO molecular clouds are fit, the best-fitting spiral model gives a pitch angle of 9.°3 ± 0.°7.

  18. Arm and leg substrate utilization and muscle adaptation after prolonged low-intensity training

    DEFF Research Database (Denmark)

    Helge, Jørn Wulff

    2010-01-01

    This review will focus on current data where substrate metabolism in arm and leg muscle is investigated and discuss the presence of higher carbohydrate oxidation and lactate release observed during arm compared with leg exercise. Furthermore, a basis for a possible difference in substrate partiti...... at comparable workloads. Finally, the influence and capacity of low-intensity training to influence metabolic fitness in the face of a limited effect on aerobic fitness will be challenged....... partitioning between endogenous and exogenous substrate during arm and leg exercise will be debated. Moreover the review will probe if differences between arm and leg muscle are merely a result of different training status rather than a qualitative difference in limb substrate regulation. Along this line...... the review will address the available studies on low-intensity training performed separately with arm or legs or as whole-body training to evaluate if this leads to different adaptations in arm and leg muscle resulting in different substrate utilization patterns during separate arm or leg exercise...

  19. Accuracy of the WatchBP office ABI device for office blood pressure measurement over a wide range of arm sizes.

    Science.gov (United States)

    Palatini, Paolo; Fania, Claudio; Gasparotti, Federica

    2018-04-01

    The aim of this study was to determine the accuracy of the WatchBP Office ABI monitor for office blood pressure measurement over a wide range of arm circumferences using the ANSI/AAMI/ISO 81060-2:2013 protocol. The device accuracy was tested in 88 participants whose mean±SD age was 54.5±17.6 years, whose arm circumference was 30.6±8.3 cm (range: 15-46 cm), and whose entry blood pressure (BP) was 138.3±23.4 mmHg for systolic and 83.7±14.6 mmHg for diastolic BP. Four cuffs (small, standard, large, and extra-large) suitable for arm circumferences ranging from 14.0 to 52.0 cm were used. The mean device-observer difference in the 264 separate BP data pairs was 0.7±3.8 mmHg for systolic BP and was 0.0±3.7 mmHg for diastolic BP. These data were in agreement with criterion 1 of the ANSI/AAMI/ISO 81060-2:2013 standard requirements (≤5±8 mmHg). Moreover, criterion 2 was satisfied, the mean±SD device-observer difference of the 88 participants being 0.7±3.1 and 0.0±3.2 mmHg, respectively, for systolic and diastolic BP. Good agreement between observer and device was present across the whole range of arm circumferences. These data show that the Microlife WatchBP Office ABI monitor satisfied the ANSI/AAMI/ISO 81060-2:2013 standard requirements across a wide range of arm sizes.

  20. Atmospheric Radiation Measurement Climate Research (ARM)

    Data.gov (United States)

    Federal Laboratory Consortium — With heavily instrumented field sites around the globe, the ARM Climate Research Facility provides the world's most comprehensive outdoor laboratory and data archive...

  1. Application of C-arm computed tomography in cardiology; Kardiale Anwendung der C-Arm-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Abteilung fuer Kardiologie, Medizinische Poliklinik, Muenchen (Germany); Rohkohl, C. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Lehrstuhl fuer Mustererkennung, Department Informatik, Erlangen (Germany); Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Lauritsch, G. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Rittger, H. [Krankenhaus Coburg, Abteilung fuer Kardiologie, Coburg (Germany); Meissner, O. [Siemens AG, Healthcare Sector, Forchheim, Forchheim (Germany); Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2009-09-15

    C-arm computed tomography is currently being introduced into cardiac imaging and offers the potential for three-dimensional imaging of the cardiac anatomy within the interventional environment. This detailed view is necessary to support complex interventional strategies, such as transcutaneous valve replacement, interventional therapy of atrial fibrillation, implantation of biventricular pacemakers and assessment of myocardial perfusion. Currently, the major limitation of this technology is its insufficient temporal resolution which limits the visualization of fast moving parts of the heart. (orig.) [German] Durch die Entwicklung der C-Arm-Computertomographie- (CACT-)Angiographie ist es erstmals moeglich, waehrend einer Herzkatheteruntersuchung eine detaillierte dreidimensionale Darstellung der kardialen Anatomie zu erhalten. Derartige zusaetzliche Informationen koennten die Durchfuehrung der immer komplexer werdenden Strategien der interventionellen Kardiologie wirkungsvoll unterstuetzen. Hierzu zaehlen u. a. der transkutane Klappenersatz, die interventionelle Behandlung von Vorhofflimmern, die Implantation biventrikulaerer Schrittmacher sowie die Beurteilung der Myokardperfusion. Die derzeit groesste Limitation dieser Methode ist die relativ geringe zeitliche Aufloesung, die aufgrund der Bewegung des Herzens die Anwendung dieser Technologie einschraenkt. (orig.)

  2. Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.

    Science.gov (United States)

    Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan

    2016-08-15

    Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.

  3. Patterns of arm muscle activation involved in octopus reaching movements.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Fiorito, G; Hochner, B

    1998-08-01

    The extreme flexibility of the octopus arm allows it to perform many different movements, yet octopuses reach toward a target in a stereotyped manner using a basic invariant motor structure: a bend traveling from the base of the arm toward the tip (Gutfreund et al., 1996a). To study the neuronal control of these movements, arm muscle activation [electromyogram (EMG)] was measured together with the kinematics of reaching movements. The traveling bend is associated with a propagating wave of muscle activation, with maximal muscle activation slightly preceding the traveling bend. Tonic activation was occasionally maintained afterward. Correlation of the EMG signals with the kinematic variables (velocities and accelerations) reveals that a significant part of the kinematic variability can be explained by the level of muscle activation. Furthermore, the EMG level measured during the initial stages of movement predicts the peak velocity attained toward the end of the reaching movement. These results suggest that feed-forward motor commands play an important role in the control of movement velocity and that simple adjustment of the excitation levels at the initial stages of the movement can set the velocity profile of the whole movement. A simple model of octopus arm extension is proposed in which the driving force is set initially and is then decreased in proportion to arm diameter at the bend. The model qualitatively reproduces the typical velocity profiles of octopus reaching movements, suggesting a simple control mechanism for bend propagation in the octopus arm.

  4. Synthesis of Well-Defined Three-Arm Star-Branched Polystyrene through Arm-First Coupling Approach by Atom Transfer Radical Polymerization

    Directory of Open Access Journals (Sweden)

    Syed Shahabuddin

    2015-01-01

    Full Text Available Here we describe a simple route to synthesize three-arm star-branched polystyrene. Atom transfer radical polymerization technique has been utilized to yield branched polystyrene involving Williamson coupling strategy. Initially a linear polymeric chain of predetermined molecular weight has been synthesized which is further end-functionalized into a primary alkyl bromide moiety, a prime requisition for Williamson reaction. The end-functionalized polymer is then coupled using 1,1,1-tris(4-hydroxyphenylethane, a trifunctional core molecule, to give well-defined triple-arm star-branched polystyrene.

  5. Piezoelectric micromotor based on the structure of serial bending arms.

    Science.gov (United States)

    Tong, Jianhua; Cui, Tianhong; Shao, Peige; Wang, Liding

    2003-09-01

    This paper presents a new piezoelectric micromotor based on the structure of serial bending arms. Serial bending arms are composed of two piezoelectric bimorphs with one end fixed and the other end free, driven by two signals of a biased square wave with a phase difference of pi/2. The free end of a cantilever arm will move along an elliptic orbit so that the cantilever is used to drive a cylinder rotor. The rotor's end surface contacts the free end of the cantilever, resulting in the rotor's rotation. There are six serial bending arms anchored on the base. The driving mechanism of the micromotor is proposed and analyzed. A new micromotor prototype, 5 mm in diameter, has been fabricated and characterized. The maximum rotational speed reaches 325 rpm, and the output torque is about 36.5 microNm.

  6. Optimal Control of Holding Motion by Nonprehensile Two-Cooperative-Arm Robot

    Directory of Open Access Journals (Sweden)

    Changan Jiang

    2016-01-01

    Full Text Available Recently, more researchers have focused on nursing-care assistant robot and placed their hope on it to solve the shortage problem of the caregivers in hospital or nursing home. In this paper, a nonprehensile two-cooperative-arm robot is considered to realize holding motion to keep a two-rigid-link object (regarded as a care-receiver stable on the robot arms. By applying Newton-Euler equations of motion, dynamic model of the object is obtained. In this model, for describing interaction behavior between object and robot arms in the normal direction, a viscoelastic model is employed to represent the normal forces. Considering existence of friction between object and robot arms, LuGre dynamic model is applied to describe the friction. Based on the obtained model, an optimal regulator is designed to control the holding motion of two-cooperative-arm robot. In order to verify the effectiveness of the proposed method, simulation results are shown.

  7. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. 78 FR 46579 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-08-01

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-30] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: FMS case YAD-$22M-16Jan10. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid: None...

  9. 78 FR 78941 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-12-27

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-70] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... any: FMS Case GAC--$82M--12Mar10 (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to be Paid...

  10. 76 FR 72686 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-11-25

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-47] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This..., if any: FMS Case FAL-$73M-6Apr11 (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed To Be...

  11. 76 FR 60461 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2011-09-29

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 11-27] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... any: FMS Case JAH-$402 million-11Dec91. FMS Case ZUF-$375 million-22Dec08. (vi) Sales Commission, Fee...

  12. 77 FR 42711 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-07-20

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-20] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This..., Amd 3). (v) Prior Related Cases, if any: FMS case ULJ-$46M-15Jan10. (vi) Sales Commission, Fee, etc...

  13. 78 FR 32632 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-05-31

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-28] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-31Dec06. FMS case NZU-$93 million-19Aug10. (vi) Sales Commission, Fee, etc., Paid, Offered, or Agreed to...

  14. 78 FR 26328 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-05-06

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-06] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...) Prior Related Cases, if any: FMS case QAA-$301M-3Dec08. (vi) Sales Commission, Fee, etc., Paid, Offered...

  15. 77 FR 46417 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-08-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-39] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...: USA (UAF) (v) Prior Related Cases, if any: FMS case UAD-$95M-23Jan12 (vi) Sales Commission, Fee, etc...

  16. Highly sensitive detection of individual HEAT and ARM repeats with HHpred and COACH.

    Science.gov (United States)

    Kippert, Fred; Gerloff, Dietlind L

    2009-09-24

    HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high

  17. Kinematic equations for resolved-rate control of an industrial robot arm

    Science.gov (United States)

    Barker, L. K.

    1983-01-01

    An operator can use kinematic, resolved-rate equations to dynamically control a robot arm by watching its response to commanded inputs. Known resolved-rate equations for the control of a particular six-degree-of-freedom industrial robot arm and proceeds to simplify the equations for faster computations are derived. Methods for controlling the robot arm in regions which normally cause mathematical singularities in the resolved-rate equations are discussed.

  18. User interface development and metadata considerations for the Atmospheric Radiation Measurement (ARM) archive

    Science.gov (United States)

    Singley, P. T.; Bell, J. D.; Daugherty, P. F.; Hubbs, C. A.; Tuggle, J. G.

    1993-01-01

    This paper will discuss user interface development and the structure and use of metadata for the Atmospheric Radiation Measurement (ARM) Archive. The ARM Archive, located at Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, is the data repository for the U.S. Department of Energy's (DOE's) ARM Project. After a short description of the ARM Project and the ARM Archive's role, we will consider the philosophy and goals, constraints, and prototype implementation of the user interface for the archive. We will also describe the metadata that are stored at the archive and support the user interface.

  19. ARM Data File Standards Version: 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Kehoe, Kenneth [University of Oklahoma; Beus, Sherman [Pacific Northwest National Laboratory; Cialella, Alice [Brookhaven National Laboratory; Collis, Scott [Argonne National Laboratory; Ermold, Brian [Pacific Northwest National Laboratory; Perez, Robin [State University of New York, Albany; Shamblin, Stefanie [Oak Ridge National Laboratory; Sivaraman, Chitra [Pacific Northwest National Laboratory; Jensen, Mike [Brookhaven National Laboratory; McCord, Raymond [Oak Ridge National Laboratory; McCoy, Renata [Sandia National Laboratories; Moore, Sean [Alliant Techsystems, Inc.; Monroe, Justin [University of Oklahoma; Perkins, Brad [Los Alamos National Laboratory; Shippert, Tim [Pacific Northwest National Laboratory

    2014-04-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility performs routine in situ and remote-sensing observations to provide a detailed and accurate description of the Earth atmosphere in diverse climate regimes. The result is a diverse data sets containing observational and derived data, currently accumulating at a rate of 30 TB of data and 150,000 different files per month (http://www.archive.arm.gov/stats/storage2.html). Continuing the current processing while scaling this to even larger sizes is extremely important to the ARM Facility and requires consistent metadata and data standards. The standards described in this document will enable development of automated analysis and discovery tools for the ever-growing volumes of data. It also will enable consistent analysis of the multiyear data, allow for development of automated monitoring and data health status tools, and facilitate development of future capabilities for delivering data on demand that can be tailored explicitly to user needs. This analysis ability will only be possible if the data follows a minimum set of standards. This document proposes a hierarchy that includes required and recommended standards.

  20. The future of U.S.-Russia nuclear arms control

    Science.gov (United States)

    Pifer, Steven

    2017-11-01

    Nuclear arms control has long made contributions to U.S.-Soviet and U.S.-Russian security, but the current regime is at risk. The 1987 Intermediate-range Nuclear Forces Treaty may be headed for collapse. Both the United States and Russia are modernizing their strategic forces, and the fate of the 2010 New Strategic Arms Reduction Treaty is unclear. In the unlikely case that the sides are prepared to go beyond New START, there are ways to address further reductions and related issues. A collapse of the arms control regime, on the other hand, would mean the end of constraints on U.S. and Russian nuclear forces, a significant loss of transparency, and potential costs to U.S. security.

  1. Searching for the Perseus arm in the anticenter direction

    Directory of Open Access Journals (Sweden)

    Figueras F.

    2012-02-01

    Full Text Available Here we propose a two step approach to provide new insights on the outer spiral arm pattern of the Milky Way: 1 a Strömgren photometric survey to map the stellar space density of moderate young type stars tracing the Perseus arm, and 2 a spectroscopic survey to determine the velocity perturbation due to the density wave through accurate Radial Velocity (RV, hereafter. First reduced preliminary data suggest an overdensity around 1.5–2 kpc, probably associated with the Perseus arm. Results from this project will present a significant step towards mapping the spiral structure between the second and the third galactic quadrant, where the determination of kinematic distances is not possible.

  2. 78 FR 65451 - Agency Information Collection (Shoulder and Arm Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-10-31

    ... and Arm Conditions Disability Benefits Questionnaire) Activity Under OMB Review AGENCY: Veterans... Control No. 2900- NEW (Shoulder and Arm Conditions Disability Benefits Questionnaire)'' in any... Benefits Questionnaire).'' SUPPLEMENTARY INFORMATION: Title: (Shoulder and Arm Conditions Disability...

  3. The Implications of a New ERa in Arms Control -- Perspectives and Analysis

    International Nuclear Information System (INIS)

    Mladineo, Stephen V.; Durbin, Karyn R.; Indusi, Joseph P.; Smoot, John L.; Vannoni, Michael G.; Satkowiak, Lawrence J.

    2004-01-01

    On November 13, 2003 the INMM hosted a workshop in Washington, DC entitled 'The Implications of a New Era in Arms Control on Regional Nonproliferation and Nuclear Materials Management'. In this paper we summarize the workshop's highlights and provide our analysis of the dominant themes. Ambassador Linton Brooks, Administrator of the National Nuclear Security Agency (NNSA), delivered the keynote address and focused on four points that are key to understanding the new era: (1) The demise of traditional East/West arms control; (2) The new strategic relationship between Russia and the United States; (3) The blurring of the distinction between nonproliferation and counter-terrorism; (4) The growing recognition that the nonproliferation regime is no longer adequate and needs to be strengthened. He issued a set of challenges to the workshop participants: if his premises were right, what should replace the lexicon of arms control? He described a four-part strategy for nuclear materials protection in Russia, and asked if that model should be replicated globally - potentially by leveraging the new relationship with Russia. Should it be through the IAEA, bilaterally, or some other mechanism? Asserting that the old Nonproliferation Treaty regime was inadequate, he asked what should replace it, and how do we bring it about? Three panel discussions were presented: (1) Implications of a New Era in US/Russia Arms Control Agreements; (2) Implications of a New in Arms Control Upon Regional Nuclear Nonproliferation: South Asia/East Asia/Middle East; and (3) Nuclear Materials Management in a New Era of Arms Control In the first panel, Daryl Kimball, Executive Director of the Arms Control Association argued that arms control agreements provided predictability in the reduction of arms, and had been successful in advancing the methods of verification. Lucas Fischer, the Deputy Assistant Secretary for Arms Control at the US State Department acknowledged that INF and START provide a basis

  4. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    Science.gov (United States)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  5. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  6. EU Armed Forces’ Use of Social Media in Areas of Deployment

    Directory of Open Access Journals (Sweden)

    Maria Hellman

    2016-02-01

    Full Text Available The advent of social media can be seen both as a risk and an opportunity by armed forces. Previous research has primarily examined whether or not the use of social media endangers or strengthens armed forces’ strategic narrative. We examine armed forces’ perceptions of risks and opportunities on a broad basis, with a particular focus on areas of deployment. The article is based on a survey of perceptions of social media amongst the armed forces of EU member states, thus adding to previous research through its comparative perspective. Whereas previous research has mainly focused on larger powers, such as the US and the UK, this article includes the views of the armed forces of 26 EU states, including several smaller nations. In analyzing the results we asked whether or not risk and opportunity perceptions were related to national ICT maturity and the existence of a social media strategy. The analysis shows that perceptions of opportunities outweigh perceptions of risks, with marketing and two-way communication as the two most prominent opportunities offered by the use of social media. Also, armed forces in countries with a moderate to high ICT maturity emphasize social media as a good way for marketing purposes.

  7. Human arm stiffness and equilibrium-point trajectory during multi-joint movement.

    Science.gov (United States)

    Gomi, H; Kawato, M

    1997-03-01

    By using a newly designed high-performance manipulandum and a new estimation algorithm, we measured human multi-joint arm stiffness parameters during multi-joint point-to-point movements on a horizontal plane. This manipulandum allows us to apply a sufficient perturbation to subject's arm within a brief period during movement. Arm stiffness parameters were reliably estimated using a new algorithm, in which all unknown structural parameters could be estimated independent of arm posture (i.e., constant values under any arm posture). Arm stiffness during transverse movement was considerably greater than that during corresponding posture, but not during a longitudinal movement. Although the ratios of elbow, shoulder, and double-joint stiffness were varied in time, the orientation of stiffness ellipses during the movement did not change much. Equilibrium-point trajectories that were predicted from measured stiffness parameters and actual trajectories were slightly sinusoidally curved in Cartesian space and their velocity profiles were quite different from the velocity profiles of actual hand trajectories. This result contradicts the hypothesis that the brain does not take the dynamics into account in movement control depending on the neuromuscular servo mechanism; rather, it implies that the brain needs to acquire some internal models of controlled objects.

  8. The effect of the development of theatre missile defences on the arms control structure

    International Nuclear Information System (INIS)

    Liu Min

    1998-01-01

    Th arms control structure usually refers to current and past results of the efforts by the USA and former Soviet Union to negotiate strategic arms control agreements. The structure is to be represented by the various arms control agreements, such as the Strategic Arms Limitation Talks (SALT) and the strategic Reduction Talks (START). Whatever the motives of the parties to these agreements, today people commonly regard the structure as the best way to achieve strategic stability. The profile od arms control and the impact of the Anti-Ballistic Missile (ABM) Treaty, to understand how the Theatre Missile Defence (TMD) program affects the arms control structure

  9. The importance of domestic law to international arms control

    International Nuclear Information System (INIS)

    Lehman, R.F. II.

    1993-11-01

    Studies of arms control and disarmament tend to focus on political, military, and diplomatic processes. Recently, in the context of the conversion of defense activities to civilian use, the economic aspects of arms control have also received renewed interest. The legal dimension, however, is in need of fresh examination. Both international and domestic law are sailing increasingly in uncharted waters. Recent arms control agreements and related developments in international peacekeeping have expanded the scope of international law and altered how one perceives certain fundamentals, including the principle of national sovereignty. Still, the nation state is largely unchallenged as the primary actor in international affairs. National governments retain near absolute sovereign rights and responsibilities even in an age of trans-national economic integration and codified international norms for human rights, freedom of the press, and the peaceful resolution of disputes. Indeed, the role of domestic law in arms control and disarmament may be more significant now than ever before. A brief review of relationships between arms control and domestic law should illustrate ways in which ones thinking has been underestimating the importance of domestic law. Hopefully, this survey will set the stage properly for the excellent, more detailed case studies by Elinor Hammarskjold and Alan Crawford. Toward that end, this paper will highlight a number of more general, and sometimes provocative, themes. These themes should be kept in mind when those two complementary presentations are considered

  10. The importance of domestic law to international arms control

    Energy Technology Data Exchange (ETDEWEB)

    Lehman, R.F. II

    1993-11-01

    Studies of arms control and disarmament tend to focus on political, military, and diplomatic processes. Recently, in the context of the conversion of defense activities to civilian use, the economic aspects of arms control have also received renewed interest. The legal dimension, however, is in need of fresh examination. Both international and domestic law are sailing increasingly in uncharted waters. Recent arms control agreements and related developments in international peacekeeping have expanded the scope of international law and altered how one perceives certain fundamentals, including the principle of national sovereignty. Still, the nation state is largely unchallenged as the primary actor in international affairs. National governments retain near absolute sovereign rights and responsibilities even in an age of trans-national economic integration and codified international norms for human rights, freedom of the press, and the peaceful resolution of disputes. Indeed, the role of domestic law in arms control and disarmament may be more significant now than ever before. A brief review of relationships between arms control and domestic law should illustrate ways in which ones thinking has been underestimating the importance of domestic law. Hopefully, this survey will set the stage properly for the excellent, more detailed case studies by Elinor Hammarskjold and Alan Crawford. Toward that end, this paper will highlight a number of more general, and sometimes provocative, themes. These themes should be kept in mind when those two complementary presentations are considered.

  11. Managing the backscatter component from the robotic arm of an a-Si EPID

    International Nuclear Information System (INIS)

    Lee, C.G.; Menk, F.; Greer, P.B.

    2010-01-01

    Full text: Backscatter from the robotic arm mechanism of an a-Si EPID in IMRT images was examined. Images corrected with a conventional flood field (FF) containing a backscatter component (BSC) from the robotic ann were compared with a BSC-free FF. A Yarian 21 EX linac (6 MV, 18 MV) was used. All images were acquired with two aS500 EPIDs, one R-arm and one E-arm. The BSC of an EPID image is the ratio of an image acquired with the EPID attached to the arm then detaching the arm from the EPID and acquiring the same image. A range of square field sizes from 2.5 x 2.5 cm to 27.5 x 27.5 cm were acquired and the BSC analyzed. The BSC of the FFs were also measured. A series of IMRT fields were acquired. Each field was corrected with a conventional FF and compared with a BSC-free FF. Figure I shows the magnitude of the BSC from each arm in the inplane for a 6 x beam. Square fields above 16 x l6 cm (R-arm) and lO x 10 cm (E-arm) benefited from a conventional FF as it tended to cancel out the BSC in the acquired square field. The opposite was observed for smaller field sizes. A gamma analysis of the IMRT fields showed a FF correction containing a BSC reduces the effect of the arm in the final image. IMRT EPID images using conventional FFs have been shown to be less affected by backscatter from the robotic arm compared to BSC-free flood fields. (author)

  12. Nuclear physicist, arms control advocate

    CERN Multimedia

    Chang, K

    2002-01-01

    Victor F. Weisskopf, a nuclear physicist who worked on the Manhattan Project to build the first atomic bomb in World War II and later became an ardent advocate of arms control, died Monday at his home in Newton, MA, USA. He was 93 (1 page).

  13. The ARM-GCSS Intercomparison Study of Single-Column Models and Cloud System Models

    International Nuclear Information System (INIS)

    Cederwall, R.T.; Rodriques, D.J.; Krueger, S.K.; Randall, D.A.

    1999-01-01

    The Single-Column Model (SCM) Working Group (WC) and the Cloud Working Group (CWG) in the Atmospheric Radiation Measurement (ARM) Program have begun a collaboration with the GEWEX Cloud System Study (GCSS) WGs. The forcing data sets derived from the special ARM radiosonde measurements made during the SCM Intensive Observation Periods (IOPs), the wealth of cloud and related data sets collected by the ARM Program, and the ARM infrastructure support of the SCM WG are of great value to GCSS. In return, GCSS brings the efforts of an international group of cloud system modelers to bear on ARM data sets and ARM-related scientific questions. The first major activity of the ARM-GCSS collaboration is a model intercomparison study involving SCMs and cloud system models (CSMs), also known as cloud-resolving or cloud-ensemble models. The SCM methodologies developed in the ARM Program have matured to the point where an intercomparison will help identify the strengths and weaknesses of various approaches. CSM simulations will bring much additional information about clouds to evaluate cloud parameterizations used in the SCMs. CSMs and SCMs have been compared successfully in previous GCSS intercomparison studies for tropical conditions. The ARM Southern Great Plains (SGP) site offers an opportunity for GCSS to test their models in continental, mid-latitude conditions. The Summer 1997 SCM IOP has been chosen since it provides a wide range of summertime weather events that will be a challenging test of these models

  14. Locomotor-like leg movements evoked by rhythmic arm movements in humans.

    Directory of Open Access Journals (Sweden)

    Francesca Sylos-Labini

    Full Text Available Motion of the upper limbs is often coupled to that of the lower limbs in human bipedal locomotion. It is unclear, however, whether the functional coupling between upper and lower limbs is bi-directional, i.e. whether arm movements can affect the lumbosacral locomotor circuitry. Here we tested the effects of voluntary rhythmic arm movements on the lower limbs. Participants lay horizontally on their side with each leg suspended in an unloading exoskeleton. They moved their arms on an overhead treadmill as if they walked on their hands. Hand-walking in the antero-posterior direction resulted in significant locomotor-like movements of the legs in 58% of the participants. We further investigated quantitatively the responses in a subset of the responsive subjects. We found that the electromyographic (EMG activity of proximal leg muscles was modulated over each cycle with a timing similar to that of normal locomotion. The frequency of kinematic and EMG oscillations in the legs typically differed from that of arm oscillations. The effect of hand-walking was direction specific since medio-lateral arm movements did not evoke appreciably leg air-stepping. Using externally imposed trunk movements and biomechanical modelling, we ruled out that the leg movements associated with hand-walking were mainly due to the mechanical transmission of trunk oscillations. EMG activity in hamstring muscles associated with hand-walking often continued when the leg movements were transiently blocked by the experimenter or following the termination of arm movements. The present results reinforce the idea that there exists a functional neural coupling between arm and legs.

  15. Admittance Control of a Multi-Finger Arm Based on Manipulability of Fingers

    Directory of Open Access Journals (Sweden)

    Takayuki Hori

    2011-09-01

    Full Text Available In the previous studies, admittance control and impedance control for a finger‐arm robot using the manipulability of the finger were studied and methods of realizing the controls have been proposed. In this study, two 3‐DOF fingers are attached to the end‐effector of a 6‐DOF arm to configure a multi‐finger arm robot. Based on the previous methods, the authors have proposed an admittance control for a multi‐finger arm robot using the manipulability of the fingers in this study. Algorithms of the averaging method and the mini‐max method were introduced to establish a manipulability criterion of the two fingers in order to generate a cooperative movement of the arm. Comparison of the admittance controls combined with the top search method and local optimization method for the multi‐finger arm robot was made and features of the control methods were also discussed. The stiffness control and damping control were experimentally evaluated to demonstrate the effectiveness of the proposed methods.

  16. Introduction on performance analysis and profiling methodologies for KVM on ARM virtualization

    Science.gov (United States)

    Motakis, Antonios; Spyridakis, Alexander; Raho, Daniel

    2013-05-01

    The introduction of hardware virtualization extensions on ARM Cortex-A15 processors has enabled the implementation of full virtualization solutions for this architecture, such as KVM on ARM. This trend motivates the need to quantify and understand the performance impact, emerged by the application of this technology. In this work we start looking into some interesting performance metrics on KVM for ARM processors, which can provide us with useful insight that may lead to potential improvements in the future. This includes measurements such as interrupt latency and guest exit cost, performed on ARM Versatile Express and Samsung Exynos 5250 hardware platforms. Furthermore, we discuss additional methodologies that can provide us with a deeper understanding in the future of the performance footprint of KVM. We identify some of the most interesting approaches in this field, and perform a tentative analysis on how these may be implemented in the KVM on ARM port. These take into consideration hardware and software based counters for profiling, and issues related to the limitations of the simulators which are often used, such as the ARM Fast Models platform.

  17. Taiwan: Major U.S. Arms Sales Since 1990

    Science.gov (United States)

    2014-03-03

    flights and tourism across the Taiwan Strait in July. While the resumption of the cross-strait dialogue for the first time in a decade was welcomed... Taiwan : Major U.S. Arms Sales Since 1990 Shirley A. Kan Specialist in Asian Security Affairs March 3, 2014 Congressional Research Service 7...number. 1. REPORT DATE 03 MAR 2014 2. REPORT TYPE 3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Taiwan : Major U.S. Arms

  18. ARM Climate Research Facility Quarterly Ingest Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Koontz, A. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2016-10-01

    The purpose of this report is to provide a concise status update for ingests maintained by the Atmospheric Radiation Measurement (ARM) Climate Research Facility. The report is divided into the following sections: (1) new ingests for which development has begun, (2) progress on existing ingests, (3) future ingests that have been recently approved, (4) other work that leads to an ingest, and (5) top requested ingests from the ARM Data Archive. New information is highlighted in blue text.

  19. ARM Climate Research Facility Quarterly Ingest Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Koontz, A. [ARM Climate Reesearch Facility, Washington, DC (United States); Sivaraman, C. [ARM Climate Reesearch Facility, Washington, DC (United States)

    2016-07-01

    The purpose of this report is to provide a concise status update for ingests maintained by the Atmospheric Radiation Measurement (ARM) Climate Research Facility. The report is divided into the following sections: (1) new ingests for which development has begun, (2) progress on existing ingests, (3) future ingests that have been recently approved, (4) other work that leads to an ingest, and (5) top requested ingests from the ARM Data Archive. New information is highlighted in blue text.

  20. Mechanical Impedance Modeling of Human Arm: A survey

    Science.gov (United States)

    Puzi, A. Ahmad; Sidek, S. N.; Sado, F.

    2017-03-01

    Human arm mechanical impedance plays a vital role in describing motion ability of the upper limb. One of the impedance parameters is stiffness which is defined as the ratio of an applied force to the measured deformation of the muscle. The arm mechanical impedance modeling is useful in order to develop a better controller for system that interacts with human as such an automated robot-assisted platform for automated rehabilitation training. The aim of the survey is to summarize the existing mechanical impedance models of human upper limb so to justify the need to have an improved version of the arm model in order to facilitate the development of better controller of such systems with ever increase in complexity. In particular, the paper will address the following issue: Human motor control and motor learning, constant and variable impedance models, methods for measuring mechanical impedance and mechanical impedance modeling techniques.

  1. Proximal biceps rupture: management of an unusual injury in an arm wrestler

    OpenAIRE

    Pratt, D A; Tennent, T D

    2007-01-01

    Arm wrestling may cause unusual injuries, which may require operative repair in the sporting individual. Injury to the proximal biceps as a consequence of arm wrestling has not been reported previously. The diagnosis and treatment of a 36‐year‐old man who sustained a proximal biceps rupture while arm wrestling and his operative management are described.

  2. Standing "the Watches" with Armed UAVs

    National Research Council Canada - National Science Library

    McCulloch, Francis

    2002-01-01

    This paper addresses the additional Options available to the operational commander in charge of conducting 'presence and monitoring' missions with the introduction of an armed capability on Unmanned Aerial Vehicles (UAVs...

  3. Comparison of Marine Boundary Layer Cloud Properties From CERES-MODIS Edition 4 and DOE ARM AMF Measurements at the Azores

    Science.gov (United States)

    Dong, X.; Xi, B.; Minnis, P.; Sun-Mack, S.

    2014-12-01

    Marine Boundary Layer (MBL) cloud properties derived for the NASA CERES Project using Terra and Aqua MODIS data are compared with observations taken at DOE ARM Mobile Facility at the Azores site from Jun. 2009 to Dec. 2010. Cloud properties derived from ARM ground-based observations were averaged over a 1-hour interval centered at the satellite overpass time, while the CERES-MODIS (CM) results were averaged within a 30×30 km2 grid box centered over the Azores site. A total of 63 daytime and 92 nighttime single-layered overcast MBL cloud cases were selected from 19 months of ARM radar-lidar and satellite observations. The CM cloud-top/base heights (Htop/Hbase) were determined from cloud-top/base temperatures (Ttop/Tbase) using a regional boundary-layer lapse rate method. For daytime comparisons, the CM-derived Htop (Hbase), on average, is 0.063 km (0.068 km) higher (lower) than its ARM radar-lidar observed counterpart, and the CM-derived Ttop and Tbase are 0.9 K less and 2.5 K greater than the surface values with high correlations (R2=0.82 and 0.84, respectively). In general, the cloud-top comparisons agree better than cloud-base comparisons because the CM Tbase and Hbase are secondary product determined from Ttop and Htop. No significant day-night difference was found in the analyses. The comparisons of microphysical properties reveal that, when averaged over a 30x30 km2 area, the CM-retrieved cloud-droplet effective radius (re) is 1.3 µm larger than that from the ARM retrievals (12.8 µm). While the CM-retrieved cloud liquid water path (LWP) is 13.5 gm-2 less than its ARM counterpart (114.2 gm-2) due to its small optical depth (τ, 9.6 vs. 13.7). The differences are reduced by 50% when the CM averages are computed only using the MODIS pixel nearest the AMF site. Using effective radius retrieved at 2.1-µm channel to calculate LWP can reduce the difference between the CM and ARM from -13.7 to 2.1 gm-2. The 10% differences between the ARM and CM LWP and re

  4. Kinematic properties of supergiants in the Perseus spiral arm

    Energy Technology Data Exchange (ETDEWEB)

    Gerasimenko, T P [Ural' skij Gosudarstvennyj Univ., Sverdlovsk (USSR)

    1963-05-01

    Large-scale inhomogeneity of the velocity field in the Perseus spiral arm region is found on the basis of the analysis of spatial motions of supergiants. The inhomogeneity seems to be connected with both presence of large groups of young stars and systematic motions in the arm predicted by the density wave theory. Proper motions of 78 stars are presented.

  5. 78 FR 76112 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-12-16

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-63] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This... case LAJ-$22M--8Mar07 FMS case GAU-$45M--25Jul08 FMS case LAL-$293M--5Jan09 (vi) Sales Commission, Fee...

  6. 77 FR 46413 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2012-08-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 12-29] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...-$131.7M-15Jun10 FMS case ZUM-$32.1M-15Jun10 FMS case ULU-$150.3M-20Oct10 (vi) Sales Commission, Fee...

  7. 78 FR 54242 - 36(b)(1) Arms Sales Notification

    Science.gov (United States)

    2013-09-03

    ... DEPARTMENT OF DEFENSE Office of the Secretary [Transmittal Nos. 13-38] 36(b)(1) Arms Sales... Department of Defense is publishing the unclassified text of a section 36(b)(1) arms sales notification. This...--$54.3M--5May04 FMS case QZX--$62.4M--24Dec03 FMS case CCZ--$48.4M--12Aug02 [[Page 54244

  8. Armed Conflict in the Chechen Republic in the French Historiography

    Directory of Open Access Journals (Sweden)

    Nikolay N. Malishevskiy

    2017-03-01

    Full Text Available The article deals with the problems of historiography of the armed conflict in the Chechen Republic. The active phase of the military operations of the armed conflict in Chechnya was completed in 2001. At that time, historians, analysts and journalists created a wide range of theoretical works concerning the conflict. A number of common features on the use of basic resources are discussed in these publications. The degree of accessibility of the sources which focus on the description of the conflict and its socio-political assessment is of great importance for researchers and their objectives. The author analyzes the European (French historiography of the armed conflict in the Chechen Republic, considers publications and specialized monographs by French authors on the given subject. The author reveals the ideas about the consequences of the armed conflict in the Chechen Republic, articulated in the works of the European researchers. For the first time within the study of the Western historiography of the war in Chechnya the author analyzes these consequences for both the Russian and Chechen sides. Being one of the most influential historical traditions, French historiography dedicated to the armed conflict in Chechnya is in the stage of development and is characterized by a number of qualitative changes and conceptual approaches.

  9. Reassignment of Drosophila willistoni Genome Scaffolds to Chromosome II Arms.

    Science.gov (United States)

    Garcia, Carolina; Delprat, Alejandra; Ruiz, Alfredo; Valente, Vera L S

    2015-10-04

    Drosophila willistoni is a geographically widespread Neotropical species. The genome of strain Gd-H4-1 from Guadeloupe Island (Caribbean) was sequenced in 2007 as part of the 12 Drosophila Genomes Project. The assembled scaffolds were joined based on conserved linkage and assigned to polytene chromosomes based on a handful of genetic and physical markers. This paucity of markers was particularly striking in the metacentric chromosome II, comprised two similarly sized arms, IIL and IIR, traditionally considered homologous to Muller elements C and B, respectively. In this paper we present the cytological mapping of 22 new gene markers to increase the number of markers mapped by in situ hybridization and to test the assignment of scaffolds to the polytene chromosome II arms. For this purpose, we generated, by polymerase chain reaction amplification, one or two gene probes from each scaffold assigned to the chromosome II arms and mapped these probes to the Gd-H4-1 strain's polytene chromosomes by nonfluorescent in situ hybridization. Our findings show that chromosome arms IIL and IIR correspond to Muller elements B and C, respectively, directly contrasting the current homology assignments in D. willistoni and constituting a major reassignment of the scaffolds to chromosome II arms. Copyright © 2015 Garcia et al.

  10. C-arm fluoroscopy: a reliable modality for retrieval of foreign bodies in the maxillofacial region.

    Science.gov (United States)

    Pandyan, Deepak; Nandakumar, N; Qayyumi, Burhanuddin N; Kumar, Santosh

    2013-11-01

    The anatomic complexity of the maxillofacial region makes the retrieval of foreign bodies a daunting task for the maxillofacial Surgeon. Moreover the inability of 2-dimensional imaging to precisely locate foreign bodies makes it challenging. The anatomic proximity of critical structures and esthetic considerations limits the access and thus poses a greater challenge for the surgeon in cases of foreign body retrieval. Hereby we propose a simple technique and a case report to support, the retrieval of small (mobile C arm Fluoroscopy and a needle triangulation method to precisely locate a loosened miniplate screw in the mandibular angle region.

  11. ARM User Survey Report: Data Access, Quality, and Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Mather, JH; Roeder, LR; Sivaraman, C

    2012-06-28

    The objective of this survey was to obtain user feedback to determine how users of the Atmospheric Radiation Measurement (ARM) Climate Research Facility Data Archive interact with the more than 2000 available types of datastreams. The survey also gathered information about data discovery and data quality. The Market and Competitive Analysis group at Pacific Northwest National Laboratory worked with web administrators to develop a landing page from which users could access the survey. A survey invitation was sent by ARM via email to about 6100 users on February 22, 2012. The invitation was also posted on the ARM website and Facebook page. Reminders were sent via e-mail and posted on Facebook while the survey was open, February 22-March 23, 2012.

  12. Concept development of a tendon arm manipulator and anthropomorphic robotic hand

    Science.gov (United States)

    Tolman, C. T.

    1987-01-01

    AMETEK/ORED inhouse research and development efforts leading toward a next-generation robotic manipulator arm and end-effector technology is summarized. Manipulator arm development has been directed toward a multiple-degree-of-freedom, flexible, tendon-driven concept referred to here as a Tendon Arm Manipulator (TAM). End-effector development has been directed toward a three-fingered, dextrous, tendon-driven, anthropomorphic configuration which is referred to as an Anthropomorphic Robotic Hand (ARH). Key technology issues are identified for both concepts.

  13. Counter-terrorism and the protection of civilians: Armed non-state actors

    OpenAIRE

    Munive, Jairo; Somer, Jonathan

    2015-01-01

    Recent events in the Middle East present the latest and undoubtedly not the last challenge to international engagement with armed non-state actors. Over the last many years international humanitarian law has increasingly regulated the behaviour of armed non-state actors with regard to the protection of civilians. At the same time, counter-terror measures have increasingly addressed such conduct, as well as controlled the extent to which other actors may interact with armed non-state actors. Y...

  14. How Computers are Arming biology!

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 23; Issue 1. In-vitro to In-silico - How Computers are Arming biology! Geetha Sugumaran Sushila Rajagopal. Face to Face Volume 23 Issue 1 January 2018 pp 83-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  15. Clinical effectiveness of decongestive treatments on excess arm volume and patient-centered outcomes in women with early breast cancer-related arm lymphedema: a systematic review

    Science.gov (United States)

    Jeffs, Eunice; Ream, Emma; Taylor, Cath; Bick, Debra

    2018-01-01

    ABSTRACT Objective: To identify the effect of decongestive lymphedema treatment on excess arm volume or patient-centered outcomes in women presenting within either 12 months or a mean nine months of developing arm lymphedema following breast cancer treatment. Introduction: Lymphedema is a common consequence of breast cancer treatment requiring life-long treatment to reduce symptoms and prevent complications. Currently, evidence to inform the optimal decongestive lymphedema treatment package is lacking. Inclusion criteria: The review included studies on women who received lymphedema treatment within either 12 months or a mean of nine months of developing unilateral breast cancer-related arm lymphedema. The intervention was any decongestive lymphedema treatment delivered with the purpose of reducing arm lymphedema, compared to another form of lymphedema treatment (whether self or practitioner-administered), placebo or no treatment. The clinical outcome was excess arm volume; patient-centered outcomes were health-related quality of life, arm heaviness, arm function, patient-perceived benefit and satisfaction with treatment. Experimental study designs were eligible, including randomized and non-randomized controlled trials, quasi-experimental, prospective and retrospective before and after studies were considered. Methods: A three-step search strategy was utilized to find published and unpublished studies. The search identified studies published from the inception of each database to July 6, 2016. Reference lists were scanned to identify further eligible studies. Studies were critically appraised using appropriate standardized critical appraisal instruments from the Joanna Briggs Institute. Details describing each study and treatment results regarding outcomes of interest were extracted from papers included in the review using appropriate standardized data extraction tools from the Joanna Briggs Institute. Due to heterogeneity in included studies, results for similar

  16. 78 FR 36307 - Proposed Information Collection (Shoulder and Arm Conditions Disability Benefits Questionnaire...

    Science.gov (United States)

    2013-06-17

    ... (Shoulder and Arm Conditions Disability Benefits Questionnaire) Activity: Comment Request AGENCY: Veterans... ``OMB Control No. 2900--NEW (Shoulder and Arm Conditions Disability Benefits Questionnaire)'' in any...: Shoulder and Arm Conditions Disability Benefits Questionnaire, VA Form 21-0960M-12. OMB Control Number...

  17. Kinematics analysis on hinges of robot arm gripper for harmful chemical handling

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Mustafa, Nurul Fahimah; Daud, Mohd Hisam

    2017-09-01

    The development of manufacturing industry is booming the application of industrial robot, and proportional to the use of robot arm. Some of the purpose of robot arm gripper is to sort things and place to the proper place. And some of the things are harmful to human, such as harmful chemical. By using robot arm to do picking and placing, it is expected to replace human tasks, as well as to reduce human from the harmful job. The problem of the robot arm gripper, most likely the problem of hinge, thus the analysis on the hinges of robot arm gripper to prevent claw is essential. By using robot arm, instead of human, is labored to do the harmful tasks and unexpected accident happen, costs and expenses in handling injured employee due to the harmful chemicals can be minimized. Thus the objective of this project is to make a kinematics analysis on the hinges of the robot arm gripper. Suitable material such as steel structure has also been selected for the construction of this hinges. This material has properties associated with compressive strength, fire resistance, corrosion and has a shape that is easy to move. Solid Works and ANSYS software is used to create animated movement on the design model and to detect deficiencies in the hinges. Detail methodology is described in this paper.

  18. Arms Production in Venezuela.

    Science.gov (United States)

    1987-12-01

    studied engineering in the United States. Cardoen produces a wide spectrum of munitions, security equipment and especially armored vehicles, and has...capabilities are: a. The amount of capital available for investment. Arms industry development requires enormous amounts of capital, especially if the...Naval Postgraduate School Monterey, CA 93943-5100 5. Director de Educacion de La Armada 1 Comandancia General de La Armada Av. Vollmer, Urb. San

  19. Kiikuv maja / Anu Arm

    Index Scriptorium Estoniae

    Arm, Anu

    2006-01-01

    Eesti Kunstiakadeemia esimese kursuse arhitektuuriüliõpilaste II semestri töö. Juhendaja arhitekt Andres Alver, ehitamise Pedaspeale organiseeris suvepraktika juhendaja arhitekt Jaan Tiidemann. Autor Anu Arm, kaasa töötasid ja valmis ehitasid: Ott Alver, Maarja Elm, Mari Hunt, Alvin Järving, Marten Kaevats, Riho Kerge, Reedik Poopuu, Anu Põime, Helen Rebane, Kaisa Saarva, Martin Tago, Reet Volt. Valmis: 19. VIII 2006

  20. U.S. – Russia Relations And Arms Control: Breating The Clinch

    Directory of Open Access Journals (Sweden)

    N. I. Bubnova

    2017-01-01

    Full Text Available The article examines the new U.S. administration’s outlook on arms control, analyses the existing problems in this field and possible ways for their resolution, compares Donald Trump’s statements on military and political issues with the president’s first steps in this area, and offers forecasts and recommendations on the prospects for U.S.-Russia cooperation in arms limitations and reductions. The author proceeds from the assumption that arms control is a key component in measures to ensure international security. Even if the current tense U.S.- Russian relations provide little room for maneuver and the internal political struggle in DC sets limits on the possible bilateral measures, Moscow should nevertheless take initiative in putting forward a set of proposals to reduce weapons, especially in the very sensitive and risk-prone nuclear field. This will allow in future negotiations to proceed from options that will take into account Russian interests and the specifics of Russia’s weapons systems, while at the same time showing the resolve of the nuclear superpowers to reduce existing threats through negotiations and leading the way for other countries to join. Taking into account the importance of arms control, all efforts should be made to enforce the existing treaties, consolidate the current international treaty-based legal system, and work further on new arms control and arms reduction agreements.

  1. Cold War Arms Control Motivations and Techniques - A Guide for the Future?

    National Research Council Canada - National Science Library

    White, Elmer

    1996-01-01

    .... This paper provides a brief historical account of some of the arms control agreements between the U.S. and the Soviet Union, examines their major motivations to enter into negotiations, and illustrates some successful negotiation techniques. The author hypothesizes on the utility of this Cold War arms control experience as a useful guide for arms control in a single superpower world.

  2. Localization Performance of Multiple Vibrotactile Cues on Both Arms.

    Science.gov (United States)

    Wang, Dangxiao; Peng, Cong; Afzal, Naqash; Li, Weiang; Wu, Dong; Zhang, Yuru

    2018-01-01

    To present information using vibrotactile stimuli in wearable devices, it is fundamental to understand human performance of localizing vibrotactile cues across the skin surface. In this paper, we studied human ability to identify locations of multiple vibrotactile cues activated simultaneously on both arms. Two haptic bands were mounted in proximity to the elbow and shoulder joints on each arm, and two vibrotactile motors were mounted on each band to provide vibration cues to the dorsal and palmar side of the arm. The localization performance under four conditions were compared, with the number of the simultaneously activated cues varying from one to four in each condition. Experimental results illustrate that the rate of correct localization decreases linearly with the increase in the number of activated cues. It was 27.8 percent for three activated cues, and became even lower for four activated cues. An analysis of the correct rate and error patterns show that the layout of vibrotactile cues can have significant effects on the localization performance of multiple vibrotactile cues. These findings might provide guidelines for using vibrotactile cues to guide the simultaneous motion of multiple joints on both arms.

  3. Visual Recognition and Its Application to Robot Arm Control

    Directory of Open Access Journals (Sweden)

    Jih-Gau Juang

    2015-10-01

    Full Text Available This paper presents an application of optical word recognition and fuzzy control to a smartphone automatic test system. The system consists of a robot arm and two webcams. After the words from the control panel that represent commands are recognized by the robot system, the robot arm performs the corresponding actions to test the smartphone. One of the webcams is utilized to capture commands on the screen of the control panel, the other to recognize the words on the screen of the tested smartphone. The method of image processing is based on the Red-Green-Blue (RGB and Hue-Saturation-Luminance (HSL color spaces to reduce the influence of light. Fuzzy theory is used in the robot arm’s position control. The Optical Character Recognition (OCR technique is applied to the word recognition, and the recognition results are then checked by a dictionary process to increase the recognition accuracy. The camera which is used to recognize the tested smartphone also provides object coordinates to the fuzzy controller, then the robot arm moves to the desired positions and presses the desired buttons. The proposed control scheme allows the robot arm to perform different assigned test functions successfully.

  4. Modulating Arm Swing Symmetry with Cognitive Load: A Window on Rhythmic Spinal Locomotor Networks in Humans?

    Science.gov (United States)

    Killeen, Tim; Easthope, Christopher S; Filli, Linard; Linnebank, Michael; Curt, Armin; Bolliger, Marc; Zörner, Björn

    2017-05-15

    In healthy subjects, changes in arm swing symmetry while walking are observed when a cognitive dual task is added, with a tendency toward left-dominant arm swing as cognitive load increases. We applied a modified Stroop word/color naming paradigm to investigate this effect in spinal cord injured (SCI) patients. Six patients with cervical SCI (cSCI), 6 with thoracic injuries (tSCI; all 12 patients American Spinal Injury Association [ASIA] Injury Score [AIS]D), and 12 healthy, matched controls underwent three-dimensional 3D gait analysis while walking normally at a comfortable speed (NW) and when performing an additional congruent (CS) and incongruent (IS) Stroop task. An arm swing symmetry index (ASI)-in which positive values indicate proportionally more movement on the left and vice versa-was calculated. Even in the baseline NW condition, all three subject groups showed larger arm movements on the left. In controls, ASI increased (NW, 13.7 ± 6.3; CS, 16.6 ± 6.4; IS, 19.6 ± 7.8) as the task became more demanding. A larger shift in tSCI patients (NW, 15.8 ± 6.0; CS, 23.4 ± 3.8; IS, 30.7 ± 4.4) was driven by a significant reduction in right wrist trajectory (p = 0.014), whereas cSCI patients showed a small reduction in mean ASI with high variability (NW, 14.2 ± 10.7; CS, 9.3 ± 13.5; IS, 6.0 ± 12.9). The effect of the IS task on ASI compared to baseline (NW) was significantly different between tSCI (+12.5 ± 6.3) and cSCI (-8.2 ± 6.0) patients (p = 0.011). Disruption of the long propriospinal connections coordinating arm and leg movements during walking may explain the heightened sensitivity to manipulation of cognitive load in tSCI, whereas the more robust automaticity in cSCI may be attributed to impaired supraspinal inputs in the context of preserved intraspinal pathways.

  5. Effects of constrained arm swing on vertical center of mass displacement during walking.

    Science.gov (United States)

    Yang, Hyung Suk; Atkins, Lee T; Jensen, Daniel B; James, C Roger

    2015-10-01

    The purpose of this study was to determine the effects of constraining arm swing on the vertical displacement of the body's center of mass (COM) during treadmill walking and examine several common gait variables that may account for or mask differences in the body's COM motion with and without arm swing. Participants included 20 healthy individuals (10 male, 10 female; age: 27.8 ± 6.8 years). The body's COM displacement, first and second peak vertical ground reaction forces (VGRFs), and lowest VGRF during mid-stance, peak summed bilateral VGRF, lower extremity sagittal joint angles, stride length, and foot contact time were measured with and without arm swing during walking at 1.34 m/s. The body's COM displacement was greater with the arms constrained (arm swing: 4.1 ± 1.2 cm, arm constrained: 4.9 ± 1.2 cm, p reaction force data indicated that the COM displacement increased in both double limb and single limb stance. However, kinematic patterns visually appeared similar between conditions. Shortened stride length and foot contact time also were observed, although these do not seem to account for the increased COM displacement. However, a change in arm COM acceleration might have contributed to the difference. These findings indicate that a change in arm swing causes differences in vertical COM displacement, which could increase energy expenditure. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Linking Publications to Instruments, Field Campaigns, Sites and Working Groups: The ARM Experience

    Science.gov (United States)

    Troyan, D.; Cialella, A. T.; Gregory, L.; Lazar, K.; Liang, M.; Ma, L.; Tilp, A.; Wagener, R.

    2017-12-01

    For the past 25 years, the ARM Climate Research Facility - a US Department of Energy scientific user facility - has been collecting atmospheric data in different climatic regimes using both in situ and remote instrumentation. Configuration of the facility's components has been designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols. Placing a premium on long-term continuous data collection resulted in terabytes of data having been collected, stored, and made accessible to any interested person. All data is accessible via the ARM.gov website and the ARM Data Discovery Tool. A team of metadata professionals assign appropriate tags to help facilitate searching the databases for desired data. The knowledge organization tools and concepts are used to create connections between data, instruments, field campaigns, sites, and measurements are familiar to informatics professionals. Ontology, taxonomy, classification, and thesauri are among the customized concepts put into practice for ARM's purposes. In addition to the multitude of data available, there have been approximately 3,000 journal articles that utilize ARM data. These have been linked to specific ARM web pages. Searches of the complete ARM publication database can be done using a separate interface. This presentation describes how ARM data is linked to instruments, sites, field campaigns, and publications through the application of standard knowledge organization tools and concepts.

  7. International Infantry and Joint Services Small Arms Systems Symposium, Exhibition and Firing Demonstration

    Science.gov (United States)

    2009-05-21

    a shoe polish tin. The company and the product were known as The Whole Kit & Caboodle. The company that began at the kitchen table of the Williams...of receivers and how well we know their positions. – Inertial navigation - Possible - DARPA recently funded development for shoe sized inertial...Future Small Caliber and 40mm Strategies  Field Capability Improvements – Green Ammunition – Case Mouth Waterproofing – Flash Suppression – Packaging

  8. OT2_tvelusam_4: Probing Galactic Spiral Arm Tangencies with [CII

    Science.gov (United States)

    Velusamy, T.

    2011-09-01

    We propose to use the unique viewing geometry of the Galactic spiral arm tangents , which provide an ideal environment for studying the effects of density waves on spiral structure. We propose a well-sampled map of the[C II] 1.9 THz line emission along a 15-degree longitude region across the Norma-3kpc arm tangential, which includes the edge of the Perseus Arm. The COBE-FIRAS instrument observed the strongest [C II] and [N II] emission along these spiral arm tangencies.. The Herschel Open Time Key Project Galactic Observations of Terahertz C+ (GOT C+), also detects the strongest [CII] emission near these spiral arm tangential directions in its sparsely sampled HIFI survey of [CII] in the Galactic plane survey. The [C II] 158-micron line is the strongest infrared line emitted by the ISM and is an excellent tracer and probe of both the diffuse gases in the cold neutral medium (CNM) and the warm ionized medium (WIM). Furthermore, as demonstrated in the GOTC+ results, [C II] is an efficient tracer of the dark H2 gas in the ISM that is not traced by CO or HI observations. Thus, taking advantage of the long path lengths through the spiral arm across the tangencies, we can use the [C II] emission to trace and characterize the diffuse atomic and ionized gas as well as the diffuse H2 molecular gas in cloud transitions from HI to H2 and C+ to C and CO, throughout the ISM. The main goal of our proposal is to use the well sampled (at arcmin scale) [C II] to study these gas components of the ISM in the spiral-arm, and inter-arm regions, to constrain models of the spiral structure and to understand the influence of spiral density waves on the Galactic gas and the dynamical interaction between the different components. The proposed HIFI observations will consist of OTF 15 degree longitude scans and one 2-degree latitude scan sampled every 40arcsec across the Norma- 3kpc Perseus Spiral tangency.

  9. Taxation, stateness and armed groups

    DEFF Research Database (Denmark)

    Hoffmann, Kasper; Vlassenroot, Koen; Marchais, Gauthier

    2016-01-01

    of authority and practices of rule that originate in the colonial era. In particular, the article shows that by appealing to both local customary and national forms of political community and citizenship, armed groups are able to assume public authority to tax civilians. However, their public authority may...

  10. 37 CFR 5.18 - Arms, ammunition, and implements of war.

    Science.gov (United States)

    2010-07-01

    ... implements of war. 5.18 Section 5.18 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK... implements of war. (a) The exportation of technical data relating to arms, ammunition, and implements of war... parts 120 through 130); the articles designated as arms, ammunitions, and implements of war are...

  11. ARM Data File Standards Version 1.2

    Energy Technology Data Exchange (ETDEWEB)

    Palanisamy, Giri [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-05-01

    The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility performs routine in situ and remote-sensing observations to provide a detailed and accurate description of the Earth atmosphere in diverse climate regimes. The result is a huge archive of diverse data sets containing observational and derived data, currently accumulating at a rate of 30 terabytes (TB) of data and 150,000 different files per month (http://www.archive.arm.gov/stats/). Continuing the current processing while scaling this to even larger sizes is extremely important to the ARM Facility and requires consistent metadata and data standards. The standards described in this document will enable development of automated analysis and discovery tools for the ever growing data volumes. It will enable consistent analysis of the multiyear data, allow for development of automated monitoring and data health status tools, and allow future capabilities of delivering data on demand that can be tailored explicitly for the user needs. This analysis ability will only be possible if the data follows a minimum set of standards. This document proposes a hierarchy of required and recommended standards.

  12. The Perseus arm in the anticenter direction

    Science.gov (United States)

    Monguió, M.; Grosbøl, P.; Figueras, F.

    2015-05-01

    The stellar overdensity due to the Perseus arm has been detected in the anticenter direction through individual field stars. For that purpose, a Str&{uml;o}mgren photometric survey covering 16° ^2 was developed with the Wide Field Camera at the Isaac Newton Telescope. This photometry allowed us to compute individual physical parameters for these stars using a new method based on atmospheric models and evolutionary tracks. The analysis of the surface density as a function of distance for intermediate young stars in this survey allowed us to detect an overdensity at 1.6±0.2 kpc from the Sun, that can be associated with the Perseus arm, with a surface density amplitude of ˜14%. The significance of the detection is above 4σ for all the cases. The fit for the radial scale length of the Galactic disk provided values in the range [2.9,3.5] kpc for the population of the B4-A1 stars. We also analyzed the interstellar visual absorption distribution, and its variation as a function of distance is coherent with a dust layer before the Perseus arm location.

  13. [Measuring the blood pressure in both arms is of little use; longitudinal study into blood pressure differences between both arms and its reproducibility in patients with diabetes mellitus type 2].

    Science.gov (United States)

    Kleefstra, N; Houweling, S T; Meyboom-de Jong, B; Bilo, H J G

    2007-07-07

    To determine the prevalence of inter-arm blood pressure differences > 10 mmHg in patients with diabetes mellitus type 2 (DM2) and to determine whether these differences are consistent over time. Descriptive. In an evaluation study of 169 DM2 patients from 5 general practices in 2003 and 2004, different methods of oscillatory measurement were used to investigate inter-arm blood pressure differences > 10 mmHg systolic or diastolic. These methods were: one measurement in each arm non-simultaneously (method A), one measurement simultaneously (B) and the mean of two simultaneous measurements (C). With method A an inter-arm blood pressure difference was found in 33% of patients. This percentage diminished to 9 with method C. In 44% (n = 7) of the patients in whom method C detected a relevant blood pressure difference, this difference was not found with method A. In 79% of patients the inter-arm blood pressure difference was not reproduced after one year. In daily practice, one non-simultaneous blood pressure measurement in each arm (method A) was of little value for identification of patients with inter-arm blood pressure differences. The reproducibility was poor one year later. Bilateral blood pressure measurement is therefore of little value.

  14. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng [Yanshan University, Hebei (China)

    2015-10-15

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  15. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    International Nuclear Information System (INIS)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng

    2015-01-01

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  16. Reprogramming the articulated robotic arm for glass handling by using Arduino microcontroller

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Kadir, Mohd Asmadi Akmal; Daud, Mohd Hisam

    2017-09-01

    The application of articulated robotic arm in industries is raised due to the expansion of using robot to replace human task, especially for the harmful tasks. However a few problems happen with the program use to schedule the arm, Thus the purpose of this project is to design, fabricate and integrate an articulated robotic arm by using Arduino microcontroller for handling glass sorting system. This project was designed to segregate glass and non-glass waste which would be pioneer step for recycling. This robotic arm has four servo motors to operate as a whole; three for the body and one for holding mechanism. This intelligent system is controlled by Arduino microcontroller and build with optical sensor to provide the distinguish objects that will be handled. Solidworks model was used to produce the detail design of the robotic arm and make the mechanical properties analysis by using a CAD software.

  17. Emergency retraction mechanism for the manipulator arm of a nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    1980-01-01

    Nuclear reactor vessels are made using numerous welds. These have to be inspected, often using ultrasonic transducers mounted on a manipulator arm. This invention seeks to solve the problem of retracting the manipulator arm should an emergency occur while it is fully extended, particularly within one of the reactor vessel nozzles. Of specific concern is the situation where power fails with the manipulator arm so extended. Details are given of an emergency retraction mechanism for use in reactor vessel inspection apparatus. A manual retraction means is used; the manipulator arm is slidably mounted within a frame. This comprises a member mounted on the arm for looping engagement by a cable, the cable being fixed at one end of the arm frame and engaging the member, and a clamp for detachably securing the cable at its other end to the arm frame at a point which is accessible from above the vessel. (U.K.)

  18. Photoelectric radar servo control system based on ARM+FPGA

    Science.gov (United States)

    Wu, Kaixuan; Zhang, Yue; Li, Yeqiu; Dai, Qin; Yao, Jun

    2016-01-01

    In order to get smaller, faster, and more responsive requirements of the photoelectric radar servo control system. We propose a set of core ARM + FPGA architecture servo controller. Parallel processing capability of FPGA to be used for the encoder feedback data, PWM carrier modulation, A, B code decoding processing and so on; Utilizing the advantage of imaging design in ARM Embedded systems achieves high-speed implementation of the PID algorithm. After the actual experiment, the closed-loop speed of response of the system cycles up to 2000 times/s, in the case of excellent precision turntable shaft, using a PID algorithm to achieve the servo position control with the accuracy of + -1 encoder input code. Firstly, This article carry on in-depth study of the embedded servo control system hardware to determine the ARM and FPGA chip as the main chip with systems based on a pre-measured target required to achieve performance requirements, this article based on ARM chip used Samsung S3C2440 chip of ARM7 architecture , the FPGA chip is chosen xilinx's XC3S400 . ARM and FPGA communicate by using SPI bus, the advantage of using SPI bus is saving a lot of pins for easy system upgrades required thereafter. The system gets the speed datas through the photoelectric-encoder that transports the datas to the FPGA, Then the system transmits the datas through the FPGA to ARM, transforms speed datas into the corresponding position and velocity data in a timely manner, prepares the corresponding PWM wave to control motor rotation by making comparison between the position data and the velocity data setted in advance . According to the system requirements to draw the schematics of the photoelectric radar servo control system and PCB board to produce specially. Secondly, using PID algorithm to control the servo system, the datas of speed obtained from photoelectric-encoder is calculated position data and speed data via high-speed digital PID algorithm and coordinate models. Finally, a

  19. Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs)

    International Nuclear Information System (INIS)

    Connolly, Bairbre; Amaral, Joao; Walsh, Sharon; Temple, Michael; Chait, Peter; Stephens, Derek

    2006-01-01

    PICCs are increasingly employed in children. Some of their risks relate to the location of the central tip. Despite care when placing lines, they sometimes move. To evaluate the influence of arm movement on the central tip location of PICCs placed in children. The central tip location of PICCs was studied in 85 children, with the arm placed in six positions. The variables of side, vein, site and arm position were examined to measure the direction and range of tip movement. The side, site or vein used did not influence the range of movement of the central tip. Change in position of the arm had a significant influence on the central tip location, moving it an average of 2.2 rib spaces, a maximum of 3.5 ribs. Elbow bending and adduction of the arm caused the central tip to move deeper into the chest, compared to when the arm was straight and abducted 90 . Arm position is the significant variable influencing PICC movement. Side, site and vein do not influence the range of movement significantly. Most PICCs descend deeper into the chest with arm adduction and elbow bending. (orig.)

  20. Suicide mortality at time of armed conflict in Ukraine.

    Science.gov (United States)

    Yur'yev, Andriy; Yur'yeva, Lyudmyla

    2015-12-01

    The purpose of this review is to explore the dynamics of suicide mortality rates in Ukraine during an ongoing armed conflict between 2014 and 2015. Suicide mortality data were obtained by reviewing annual analytical releases from the State Service for Emergent Situations of Ukraine and annual release of Russian Federal Service of State Statistics. Suicide mortality in mainland Ukraine and in the Crimea region demonstrated a mild decrease, whereas suicide mortality in the regions directly involved in the armed conflict demonstrated a prominent decrease. The results of this review support Durkheim theory. The limitation of this review includes general concern about quality of data at time of armed conflict in the country. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  1. Positioning the laparoscopic camera with industrial robot arm

    DEFF Research Database (Denmark)

    Capolei, Marie Claire; Wu, Haiyan; Andersen, Nils Axel

    2017-01-01

    This paper introduces a solution for the movement control of the laparoscopic camera employing a teleoperated robotic assistant. The project propose an autonomous robotic solution based on an industrial manipulator, provided with a modular software which is applicable to large scale. The robot arm...... industrial robot arm is designated to accomplish this manipulation task. The software is implemented in ROS in order to facilitate future extensions. The experimental results shows a manipulator capable of moving fast and smoothly the surgical tool around a remote center of motion....

  2. Solubility of lead and copper in biochar-amended small arms range soils: influence of soil organic carbon and pH.

    Science.gov (United States)

    Uchimiya, Minori; Bannon, Desmond I

    2013-08-14

    Biochar is often considered a strong heavy metal stabilizing agent. However, biochar in some cases had no effects on, or increased the soluble concentrations of, heavy metals in soil. The objective of this study was to determine the factors causing some biochars to stabilize and others to dissolve heavy metals in soil. Seven small arms range soils with known total organic carbon (TOC), cation exchange capacity, pH, and total Pb and Cu contents were first screened for soluble Pb and Cu concentrations. Over 2 weeks successive equilibrations using weak acid (pH 4.5 sulfuric acid) and acetate buffer (0.1 M at pH 4.9), Alaska soil containing disproportionately high (31.6%) TOC had nearly 100% residual (insoluble) Pb and Cu. This soil was then compared with sandy soils from Maryland containing significantly lower (0.5-2.0%) TOC in the presence of 10 wt % (i) plant biochar activated to increase the surface-bound carboxyl and phosphate ligands (PS450A), (ii) manure biochar enriched with soluble P (BL700), and (iii) unactivated plant biochars produced at 350 °C (CH350) and 700 °C (CH500) and by flash carbonization (corn). In weak acid, the pH was set by soil and biochar, and the biochars increasingly stabilized Pb with repeated extractions. In pH 4.9 acetate buffer, PS450A and BL700 stabilized Pb, and only PS450A stabilized Cu. Surface ligands of PS450A likely complexed and stabilized Pb and Cu even under acidic pH in the presence of competing acetate ligand. Oppositely, unactivated plant biochars (CH350, CH500, and corn) mobilized Pb and Cu in sandy soils; the putative mechanism is the formation of soluble complexes with biochar-borne dissolved organic carbon. In summary, unactivated plant biochars can inadvertently increase dissolved Pb and Cu concentrations of sandy, low TOC soils when used to stabilize other contaminants.

  3. Involved-Field Radiotherapy versus Elective Nodal Irradiation in Combination with Concurrent Chemotherapy for Locally Advanced Non-Small Cell Lung Cancer: A Prospective Randomized Study

    Science.gov (United States)

    Chen, Ming; Bao, Yong; Ma, Hong-Lian; Wang, Jin; Wang, Yan; Peng, Fang; Zhou, Qi-Chao; Xie, Cong-Hua

    2013-01-01

    This prospective randomized study is to evaluate the locoregional failure and its impact on survival by comparing involved field radiotherapy (IFRT) with elective nodal irradiation (ENI) in combination with concurrent chemotherapy for locally advanced non-small cell lung cancer. It appears that higher dose could be delivered in IFRT arm than that in ENI arm, and IFRT did not increase the risk of initially uninvolved or isolated nodal failures. Both a tendency of improved locoregional progression-free survival and a significant increased overall survival rate are in favor of IFRT arm in this study. PMID:23762840

  4. A Review of the Effects of Armed Conflict on Children ...

    African Journals Online (AJOL)

    Among many countries that have experienced one form of conflict, this paper tried to review the experiences of children during armed conflict in Nepal, Columbia and Nigeria. The review also delved into the impact of armed conflict on health, nutrition and education of children and further, outlined some international ...

  5. 32 CFR 250.8 - Pertinent portions of International Traffic in Arms Regulations (ITAR).

    Science.gov (United States)

    2010-07-01

    ... details of development, engineering, design, production, or manufacture of any arms, ammunition, or... the details of design, production, or manufacture of any arms, ammunition, or implements of war on the..., production, or manufacturing of any arms, ammunition, or implements of war on the U.S. Munitions List. (3) If...

  6. One-pot synthesis of star-shaped macromolecules containing polyglycidol and poly(ethylene oxide) arms.

    Science.gov (United States)

    Lapienis, Grzegorz; Penczek, Stanislaw

    2005-01-01

    Synthesis of fully hydrophilic star-shaped macromolecules with different kinds of arms (A(x)B(y)C(z)) based on polyglycidol (PGL, A(x)) and poly(ethylene oxide) (PEO, C(z)) arms and diepoxy compounds (diglycidyl ethers of ethylene glycol (DGEG) or neopentyl glycol (DGNG) in the core, B(y)) forming the core is described. Precursors of arms were prepared by polymerization of glycidol with protected -OH groups. The first-generation stars were formed in the series of consecutive-parallel reactions of arms A(x) with diepoxy compounds (B). These first-generation stars (A(x)B(y)), having approximately O-, Mt+ groups on the cores, were used as multianionic initiators for the second generation of arms (C(z)) built by polymerization of ethylene oxide. The products with M(n) up to 10(5) and having up to approximately 40 arms were obtained. The number of arms (f) was determined by direct measurements of M(n) of the first-generation stars (M(n) of arms A(x) is known), compared with f calculated from the branching index g, determined from R(g) measured with size-exclusion chromatography (SEC) triple detection with TriSEC software. The progress of the star formation was monitored by 1H NMR and SEC. These novel water-soluble stars, having a large number of hydroxyl groups, both at the ends of PEO arms as well as within the PGL arms, can be functionalized and further used for attaching compounds of interest. This approach opens, therefore, a new way of "multiPEGylation".

  7. Adaptive neural control for dual-arm coordination of humanoid robot with unknown nonlinearities in output mechanism.

    Science.gov (United States)

    Liu, Zhi; Chen, Ci; Zhang, Yun; Chen, C L P

    2015-03-01

    To achieve an excellent dual-arm coordination of the humanoid robot, it is essential to deal with the nonlinearities existing in the system dynamics. The literatures so far on the humanoid robot control have a common assumption that the problem of output hysteresis could be ignored. However, in the practical applications, the output hysteresis is widely spread; and its existing limits the motion/force performances of the robotic system. In this paper, an adaptive neural control scheme, which takes the unknown output hysteresis and computational efficiency into account, is presented and investigated. In the controller design, the prior knowledge of system dynamics is assumed to be unknown. The motion error is guaranteed to converge to a small neighborhood of the origin by Lyapunov's stability theory. Simultaneously, the internal force is kept bounded and its error can be made arbitrarily small.

  8. Obesity predicts for arm edema in conservatively treated breast cancer patients

    International Nuclear Information System (INIS)

    Werner, R.S.; McCormick, B.; Gray, J.R.; Cox, L.; Cirrincione, C.; Petrek, J.A.; Yahalom, J.

    1990-01-01

    This paper identifies risk factors for arm edema (AE) following breast-conserving surgery and radiation therapy. Upper and lower arm circumferences were measured at interval follow-up visits in 284 patients. A different of 2.5 cm or more in either measurement (treated vs untreated arms) defined AE. Possible predictors for AE examined by univariate and multivariate analysis included level of dissection; number of nodes removed; number involved; tumor size and location; use of supraclavicular fields; patient age, weight, and size (tangent separation measurement); and systemic therapy

  9. Estimation of Height from Arm Span in 6-11 Years Children in Odisha, India

    Directory of Open Access Journals (Sweden)

    Snigdha Prava Mishra

    2017-10-01

    Full Text Available Introduction: Standing height is an important anthropometric parameter to track longitudinal growth, to estimate body fatness and to calculate energy requirement. Measurement of height may be difficult in children who cannot stand. Aim: To establish regression equation for estimation of height from arm span in children. To check comparative relevancy of this equation with fixed height-to-arm span ratio (HAR for estimation of height. Materials and Methods: A cross-sectional study was conducted with 6-11 years school children (n=1465, Boys=774, Girls=691 in state of Odisha, India. Height was measured by portable stadiometer and arm span was measured by fiberglass measuring tape to nearest 0.1 cm. Pearson correlation and regression analysis was carried out between height and arm span data. p<0.05 (two tail was considered statistically significant. Results: Mean height and arm span in boys (124.16±8.74 cm and 125.57±10.43 cm respectively was significantly more (p<0.001 than height and arm span in girls (121.18±10.37 cm and 121.50±11.68 cm respectively. Mean HAR was 0.9942±0.0279. Correlation between height and arm span in boys was r = 0.94 (p<0.001 and in girls was r = 0.96 (p<0.001. Overall correlation coefficient was r = 0.95 (p<0.001. Regression equation for estimation of height from arm span was established: Height (cm = 0.8192 * arm span (cm + 21.46. Conclusion: Height in children of 6-11 years showed strong positive correlation with arm span. Regression equation established from this study can be used to estimate height from arm span. This estimation is more reliable than estimation of height from HAR.

  10. Small angle single arm spectrometer

    International Nuclear Information System (INIS)

    Chien, C.Y.

    1976-01-01

    A study is given of an experiment described in the 1975 Summer Study to review the adequacy of the apparatus for its physics goals, equipment needs, logistic needs, vacuum chambers, compatibility with other experiments and to summarize its impacts on ISABELLE. The spectrometer is designed to study single particle inclusive spectra near x = 1 with particle identification and good momentum resolution

  11. Kinematic Tests of Small Arms

    Science.gov (United States)

    2016-03-15

    muzzle devices, such as flash suppressors and muzzle compensators, if the items are designed to be operator removable. Use the ammunition that will...muzzle brake or adding a sound suppressor . A kinematics study is also a diagnostic tool to investigate weapon problems such as poor functioning with

  12. How do deltoid muscle moment arms change after reverse total shoulder arthroplasty?

    Science.gov (United States)

    Walker, David R; Struk, Aimee M; Matsuki, Keisuke; Wright, Thomas W; Banks, Scott A

    2016-04-01

    Although many advantages of reverse total shoulder arthroplasty (RTSA) have been demonstrated, a variety of complications indicate there is much to learn about how RTSA modifies normal shoulder function. This study used a subject-specific computational model driven by in vivo kinematic data to assess how RTSA affects deltoid muscle moment arms after surgery. A subject-specific 12 degree-of-freedom musculoskeletal model was used to analyze the shoulders of 26 individuals (14 RTSA and 12 normal). The model was modified from the work of Holzbaur to directly input 6 degree-of-freedom humeral and scapular kinematics obtained using fluoroscopy. The moment arms of the anterior, lateral, and posterior aspects of the deltoid were significantly different when RTSA and normal cohorts were compared at different abduction angles. Anterior and lateral deltoid moment arms were significantly larger in the RTSA group at the initial elevation of the arm. The posterior deltoid was significantly larger at maximum elevation. There was large intersubject variability within the RTSA group. Placement of implant components during RTSA can directly affect the geometric relationship between the humerus and scapula and the muscle moment arms in the RTSA shoulder. RTSA shoulders maintain the same anterior and posterior deltoid muscle moment-arm patterns as healthy shoulders but show much greater intersubject variation and larger moment-arm magnitudes. These observations provide a basis for determining optimal implant configuration and surgical placement to maximize RTSA function in a patient-specific manner. Published by Elsevier Inc.

  13. Radiotherapy in stage 3, unresectable, asymptomatic non-small cell lung cancer. Final results of a prospective randomized study of 240 patients

    International Nuclear Information System (INIS)

    Reinfuss, M.; Glinski, B.; Kowalska, T.; Kulpa, J.; Zawila, K.; Reinfuss, K.; Dymek, P.; Herman, K.; Skolyszewski, J.

    1999-01-01

    Purpose: to report the results of a prospective randomized study concerning the role of radiotherapy in the treatment of stage III, unresectable, asymptomatic non-small cell lung cancer. Material and methods: between 1992 and 1996, 240 patients with stage III, unresectable, asymptomatic non-small cell lung cancer were enrolled in this study, and sequentially randomized to one of the three treatment arms: conventional irradiation, hypo-fractionated irradiation and control group. In the conventional irradiation arm (79 patients), a dose of 50 Gy in 25 fractions in five weeks was delivered to the primary tumor and the mediastinum. In the hypo-fractionated irradiation arm (81 patients), there were two courses of irradiation separated by an interval of four weeks. In each series, patients received 20 Gy in five fractions in five days, in the same treatment volume as the conventional irradiation group. in the control group arm, 80 patients initially did not receive radiotherapy and were only observed. Delayed palliative hypo-fractionated irradiation (20-25 Gy in four to five fractions in four to five days) was given to the primary tumor when major symptoms developed. Results: the two-year actuarial survival rates for patients in the conventional irradiation, hypo-fractionated irradiation and control group arms were 18%, 6% and 0%, with a median survival time of 12 months, nine months and six months respectively. The differences between survival rates were statistically significant at the 0.05 level. Conclusion: although irradiation provides good palliation the results are disappointing. The comparison of conventional and hypo-fractionated irradiation shows an advantage for conventional schedules. (author)

  14. Liposuction of arm lymphoedema.

    OpenAIRE

    Brorson, Håkan

    2003-01-01

    Breast cancer is the most common disease in women, and up to 38% develop lymphedema of the arm following mastectomy, standard axillary node dissection and postoperative irradiation. Limb reductions have been reported utilising various conservative therapies such as manual lymph and pressure therapy. Some patients with long-standing pronounced lymphedema do not respond to these conservative treatments because slow or absent lymph flow causes the formation of excess subcutaneous adipose tissue....

  15. [Benefits of cisplatin-based polychemotherapy in non-small cell bronchogenic carcinoma. Kyushu Lung Cancer Chemotherapy Study Group].

    Science.gov (United States)

    Ohta, M; Hara, N; Ichikawa, Y; Kanda, T; Shima, K; Tamura, K; Hokama, M

    1988-06-01

    We studied the efficacy of cisplatin-based polychemotherapy for non-small-cell lung cancer. One hundred nineteen patients with adenocarcinoma or large cell carcinoma were randomized to receive cyclophosphamide, adriamycin, cisplatin and mitomycin C (CAPM) or mitomycin C, cytosine arabinoside and tegafur (MCT), and 48 patients with squamous cell carcinoma were randomized to receive cisplatin, adriamycin and peplomycin (PAP) or mitomycin C, cyclophosphamide, tespamine, toyomycin and tegafur (MCTTT). Radiation was given to the chest in patients with stage I-III disease. The response rates were CAPM, 34.5%; MCT, 13.1% (p less than 0.01) and PAP, 63.3%; MCTTT, 42.3%. A significant difference in response rate between the CAPM and MCT regimens was observed only in stage IV patients and not in stage I-III patients. The median survival was 9.5 months in the CAPM arm vs. 6.5 months in the MCT arm (p less than 0.007), and 8.5 months in the PAP arm vs. 6.5 months in the MCTTT arm. Improved median survival for the CAPM regimen was noted only in stage IV patients and not in stage I-III patients when compared to patients given the MCT regimen, respectively. Nausea and vomiting were significantly increased in patients with cisplatin-based polychemotherapy. Myelosuppression was more severe with the CAPM regimen than with the other chemotherapy regimens. We concluded that cisplatin-based polychemotherapy, CAPM and PAP therapy were of more benefit to patients with disseminated non-small-cell lung cancer than MCT and MCTTT therapy.

  16. C-arm computed tomography for transarterial chemoperfusion and chemo-embolization of thoracic lesions; Transarterielle Chemoperfusion und -embolisation thorakaler Neoplasmen mittels C-Arm CT

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.; Nour-Eldin, N.E.; Lehnert, T.; Mbalisike, E. [Klinikum der Johann-Wolfgang-Goethe-Universitaet, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany)

    2009-09-15

    To evaluate the role of C-arm CT for on-line fluoroscopy in regional transarterial chemoperfusion (TACP) and chemo-embolization (TPCE) of primary and secondary malignant thoracic lesions. From September 2008 to March 2009 a total of 31 patients (20 males and 11 females, average age: 61.7 years, range 22-84 years) with 53 thoracic malignant lesions from different origins (primary or secondary pulmonary carcinoma n=37, pleural mesothelioma n=16) were treated with TACP or TPCE using flat-detector CT (FD-CT). C-arm CT of the latest generation was used to localize the lesion before local chemotherapy (Artis Zeego, Siemens, Erlangen). For TACP a 220 rotation and a volume of 150 ml (ratio of 1:2 contrast/normal saline), delay 2 s and flow 12 ml/s was used. For TPCE a volume of 75 ml (ratio of 1:2 contrast/normal saline), delay 2 s and flow 3 ml/s was used. TPCE C-arm CT allowed the evaluation of the degree of perfusion of the tumor and the geographic areas of enhancement correlated with the post-interventional lipiodol uptake in MSCT. In TACP the intercostal arteries involved could be visualized and in 30% of interventions the catheter had to be repositioned for the following intervention. C-arm CT provides additional information on the vascular characteristics and perfusion of pulmonary lesions resulting in a change of interventional strategy in a relevant number of patients. (orig.) [German] Ziel der Arbeit war die Evaluation der Wertigkeit der C-Arm CT fuer die online gesteuerte regionale transarterielle Chemoperfusion (TACP) und die transpulmonale Chemoembolisation (TPCE) primaerer und sekundaerer thorakaler Neoplasmen Von September 2008 bis Maerz 2009 wurden 31 Patienten (11 Frauen/20 Maenner, Durchschnittsalter 61,7 Jahre) mit 53 unterschiedlichen thorakalen Neoplasmen (primaere oder sekundaere Lungenkarzinome [n=37], Pleuramesotheliome [n=16]) mittels TACP oder TPCE unter Einsatz der Flachdetektortechnologie (FD-CT) behandelt. Alle Behandlungen erfolgten an einem C

  17. Towards a digital body: the virtual arm illusion

    Directory of Open Access Journals (Sweden)

    2008-08-01

    Full Text Available The integration of the human brain with computers is an interesting new area of applied neuroscience, where one application is replacement of a person’s real body by a virtual representation. Here we demonstrate that a virtual limb can be made to feel part of your body if appropriate multisensory correlations are provided. We report an illusion that is invoked through tactile stimulation on a person’s hidden real right hand with synchronous virtual visual stimulation on an aligned 3D stereo virtual arm projecting horizontally out of their shoulder. An experiment with 21 male participants showed displacement of ownership towards the virtual hand, as illustrated by questionnaire responses and proprioceptive drift. A control experiment with asynchronous tapping was carried out with a different set of 20 male participants who did not experience the illusion. After 5 minutes of stimulation the virtual arm rotated. Evidence suggests that the extent of the illusion was also correlated with the degree of muscle activity onset in the right arm as measured by EMG during this period that the arm was rotating, for the synchronous but not the asynchronous condition. A completely virtual object can therefore be experienced as part of one’s self, which opens up the possibility that an entire virtual body could be felt as one’s own in future virtual reality applications or online games, and be an invaluable tool for the understanding of the brain mechanisms underlying body ownership.

  18. Effect of Tendon Vibration on Hemiparetic Arm Stability in Unstable Workspaces.

    Directory of Open Access Journals (Sweden)

    Megan O Conrad

    Full Text Available Sensory stimulation of wrist musculature can enhance stability in the proximal arm and may be a useful therapy aimed at improving arm control post-stroke. Specifically, our prior research indicates tendon vibration can enhance stability during point-to-point arm movements and in tracking tasks. The goal of the present study was to investigate the influence of forearm tendon vibration on endpoint stability, measured at the hand, immediately following forward arm movements in an unstable environment. Both proximal and distal workspaces were tested. Ten hemiparetic stroke subjects and 5 healthy controls made forward arm movements while grasping the handle of a two-joint robotic arm. At the end of each movement, the robot applied destabilizing forces. During some trials, 70 Hz vibration was applied to the forearm flexor muscle tendons. 70 Hz was used as the stimulus frequency as it lies within the range of optimal frequencies that activate the muscle spindles at the highest response rate. Endpoint position, velocity, muscle activity and grip force data were compared before, during and after vibration. Stability at the endpoint was quantified as the magnitude of oscillation about the target position, calculated from the power of the tangential velocity data. Prior to vibration, subjects produced unstable, oscillating hand movements about the target location due to the applied force field. Stability increased during vibration, as evidenced by decreased oscillation in hand tangential velocity.

  19. Consistency of blood pressure differences between the left and right arms.

    Science.gov (United States)

    Eguchi, Kazuo; Yacoub, Mona; Jhalani, Juhee; Gerin, William; Schwartz, Joseph E; Pickering, Thomas G

    2007-02-26

    It is unclear to what extent interarm blood pressure (BP) differences are reproducible vs the result of random error. The present study was designed to resolve this issue. We enrolled 147 consecutive patients from a hypertension clinic. Three sets of 3 BP readings were recorded, first using 2 oscillometric devices simultaneously in the 2 arms (set 1); next, 3 readings were taken sequentially for each arm using a standard mercury sphygmomanometer (set 2); finally, the readings as performed for set 1 were repeated (set 3). The protocol was repeated at a second visit for 91 patients. Large interarm systolic BP differences were consistently seen in 2 patients with obstructive arterial disease. In the remaining patients, the systolic BP and the diastolic BP, respectively, were slightly higher in the right arm than in the left arm by 2 to 3 mm Hg and by 1 mm Hg for all 3 sets (Pdifference of more than 5 mm Hg were 11 (7.5%) and 4 (2.7%) across all 3 sets of readings. Among patients who repeated the test, none had a consistent interarm BP difference of more than 5 mm Hg across the 2 visits. The interarm BP difference was consistent only when obstructive arterial disease was present. Although BP in the right arm tended to be higher than in the left arm, clinically meaningful interarm differences were not reproducible in the absence of obstructive arterial disease and are attributable to random variation.

  20. Reduced-dose C-arm computed tomography applications at a pediatric institution

    Energy Technology Data Exchange (ETDEWEB)

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2017-12-15

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance. (orig.)