WorldWideScience

Sample records for small animal bone

  1. Bone scintigraphy for the investigation of lameness in small animals

    International Nuclear Information System (INIS)

    Bolln, G.; Franke, C.

    2010-01-01

    Bone scintigraphy has been used as a helpful method in diagnosing lameness in small animals. It is a sensitive, non-invasive method to evaluate bone lesions and orthopaedic disorders. It provides a functional image of the skeleton and thereby aiding in the localisation and diagnosing of obscure lameness. Compared to human medicine one important difference is the inability of an animal to characterize its pain to the examiner. Another difference is the lacking cooperation of an animal during bone scintigraphy. Before this background are shown on the basis of 5 examples the advantages, the method and the different indication of bone scintigraphy. The technique of this method arrives from a human medicine protocol of a 2-phase-bone-scintigraphy and has to be done under light anaesthesia, to avoid artefacts of movement during acquisitions. The authors are convinced that bone scintigraphy is a very useful and diagnostic method for evaluation of obscure lameness because it can give a quick diagnosis and aimed therapy. Therefore secondary changes and additional costs can be avoided for the animal and its owner. (orig.)

  2. Discrete tomography in an in vivo small animal bone study.

    Science.gov (United States)

    Van de Casteele, Elke; Perilli, Egon; Van Aarle, Wim; Reynolds, Karen J; Sijbers, Jan

    2018-01-01

    This study aimed at assessing the feasibility of a discrete algebraic reconstruction technique (DART) to be used in in vivo small animal bone studies. The advantage of discrete tomography is the possibility to reduce the amount of X-ray projection images, which makes scans faster and implies also a significant reduction of radiation dose, without compromising the reconstruction results. Bone studies are ideal for being performed with discrete tomography, due to the relatively small number of attenuation coefficients contained in the image [namely three: background (air), soft tissue and bone]. In this paper, a validation is made by comparing trabecular bone morphometric parameters calculated from images obtained by using DART and the commonly used standard filtered back-projection (FBP). Female rats were divided into an ovariectomized (OVX) and a sham-operated group. In vivo micro-CT scanning of the tibia was done at baseline and at 2, 4, 8 and 12 weeks after surgery. The cross-section images were reconstructed using first the full set of projection images and afterwards reducing them in number to a quarter and one-sixth (248, 62, 42 projection images, respectively). For both reconstruction methods, similar changes in morphometric parameters were observed over time: bone loss for OVX and bone growth for sham-operated rats, although for DART the actual values were systematically higher (bone volume fraction) or lower (structure model index) compared to FBP, depending on the morphometric parameter. The DART algorithm was, however, more robust when using fewer projection images, where the standard FBP reconstruction was more prone to noise, showing a significantly bigger deviation from the morphometric parameters obtained using all projection images. This study supports the use of DART as a potential alternative method to FBP in X-ray micro-CT animal studies, in particular, when the number of projections has to be drastically minimized, which directly reduces

  3. Small animals bone density and morphometry analysis with a dual energy X-rays absorptiometry bone densitometer using a 2D digital radiographic detector

    International Nuclear Information System (INIS)

    Boudousq, V.; Bordy, T.; Gonon, G.; Dinten, J.M.

    2004-01-01

    LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. In previous papers, technical principles and patients' Bone Mineral Density (BMD) measurement performances were presented. Bone densitometers are also used on small animals for drug development. In this presentation, we show how LEXXOS can be adapted for small animals' examinations and evaluate its performances. At first, in order to take advantage of the whole area of the 20 x 20 cm 2 digital radiographic detector, it has been made profit of X-Rays magnification by adapting the geometrical configuration. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the averaged total body BMD has been measured. This evaluation shows that the right order of BMD magnitude is obtained and, as expected, BMD increases on two sets until a period around puberty and the ovariectomized set presents a significant decrease after. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing useful complementary information on bone morphometry and architecture. This study shows that LEXXOS cone beam bone densitometer provides simultaneously useful quantitative and qualitative information for analysis of bone evolution on small animals. In the future, same system architecture and processing methodology can be used with higher resolution detectors in order to refine information on bone architecture. (authors)

  4. Whole bone testing in small animals: systematic characterization of the mechanical properties of different rodent bones available for rat fracture models.

    Science.gov (United States)

    Prodinger, Peter M; Foehr, Peter; Bürklein, Dominik; Bissinger, Oliver; Pilge, Hakan; Kreutzer, Kilian; von Eisenhart-Rothe, Rüdiger; Tischer, Thomas

    2018-02-14

    Rat fracture models are extensively used to characterize normal and pathological bone healing. Despite, systematic research on inter- and intra-individual differences of common rat bones examined is surprisingly not available. Thus, we studied the biomechanical behaviour and radiological characteristics of the humerus, the tibia and the femur of the male Wistar rat-all of which are potentially available in the experimental situation-to identify useful or detrimental biomechanical properties of each bone and to facilitate sample size calculations. 40 paired femura, tibiae and humeri of male Wistar rats (10-38 weeks, weight between 240 and 720 g) were analysed by DXA, pQCT scan and three-point-bending. Bearing and loading bars of the biomechanical setup were adapted percentually to the bone's length. Subgroups of light (skeletal immature) rats under 400 g (N = 11, 22 specimens of each bone) and heavy (mature) rats over 400 g (N = 9, 18 specimens of each bone) were formed and evaluated separately. Radiologically, neither significant differences between left and right bones, nor a specific side preference was evident. Mean side differences of the BMC were relatively small (1-3% measured by DXA and 2.5-5% by pQCT). Over all, bone mineral content (BMC) assessed by DXA and pQCT (TOT CNT, CORT CNT) showed high correlations between each other (BMC vs. TOT and CORT CNT: R 2  = 0.94-0.99). The load-displacement diagram showed a typical, reproducible curve for each type of bone. Tibiae were the longest bones (mean 41.8 ± 4.12 mm) followed by femurs (mean 38.9 ± 4.12 mm) and humeri (mean 29.88 ± 3.33 mm). Failure loads and stiffness ranged from 175.4 ± 45.23 N / 315.6 ± 63.00 N/mm for the femurs, 124.6 ± 41.13 N / 260.5 ± 59.97 N/mm for the humeri to 117.1 ± 33.94 N / 143.8 ± 36.99 N/mm for the tibiae. Smallest interindividual differences were observed in failure loads of the femurs (CV% 8.6) and tibiae (CV% 10.7) of heavy

  5. Enxerto ósseo esponjoso autólogo em pequenos animais Autologous cancellous bone graft in small animals

    Directory of Open Access Journals (Sweden)

    Fernanda Carpi dos Santos

    2004-12-01

    Full Text Available O enxerto ósseo esponjoso autólogo é formado por osso trabecular, poroso e altamente celular. Visto ser de fundamental importância na cirurgia ortopédica de pequenos animais, o trabalho teve por objetivo discorrer sobre a função, locais de colheita, cuidados, formas de aplicação, indicações e contra-indicações desse enxerto. Ele estimula a formação óssea devido ao fornecimento de células vivas e fatores de crescimento, mas não possui suporte mecânico. A asa do ílio craniodorsal, úmero proximal, tíbia proximal e fêmur distal, são os locais de colheita mais utilizados em cães. A asa do ílio consiste no local mais satisfatório para gatos. Para maximizar a incorporação do enxerto com o tecido hospedeiro, devem ser tomados alguns cuidados entre a colheita e a transferência para a área receptora. Além disso, pode ser aplicado sem compressão dentro do local recipiente. A freqüência de complicações é considerada baixa.The autologous cancellous bone is formed by trabecular bone, porous, and highly cellular. Since this graft is very important in orthopedic surgery of small animals, the purpose of this paper is to describe the function, donor sites, precautions, application methods, indications, and contraindications. It stimulates the bone formation because it provides live cells and growth factors, but it did not have mechanical support. Cranial dorsal wing of the ilium, proximal humerus, proximal tibia, and distal femur are the most common harvest sites used in dogs. The wing of the ilium is the most satisfactory harvest site in cats. To maximize the graft incorporation with the tissue it is necessary to take care during the harvest and transference to recipient site. In addition, it may be put into the recipient site with no compression. The frequency of complications is considered low.

  6. Precision of high-resolution dual energy x-ray absorptiometry of bone mineral status and body composition in small animal models

    Directory of Open Access Journals (Sweden)

    Lochmüller E. M.

    2001-01-01

    Full Text Available The purpose of this study was to analyze the in situ precision (reproducibility of bone mineral and body composition measurements in mice of different body weights and rats, using a high-resolution DXA (dual energy X-ray absorptiometry scanner. We examined 48 NMRI mice weighing approximately 10 to 60 g, and 10 rats weighing approximately 140 g. Four repeated measurements were obtained on different days. In mice, the standard deviations of repeated measurements ranged from 2.5 to 242 mg for bone mineral content (BMC, from 0.16 to 3.74 g for fat, and from 0.40 to 4.21 g for lean mass. The coefficient of variation in percent (CV% for BMC/BMD (bone mineral density was highest in the 10 g mice (12.8% / 4.9% and lowest in the 40 g mice (3.5% /1.7%. In rats, it was 2.5 /1.2% in the lower extremity, 7.1/3.0 % in the spine, 5.7/2.0 % in the femur, and 3.6%/2.1% in the tibia. The CV% for fat and lean mass in mice was higher than for BMC. The study demonstrates good precision of bone mineral and moderate precision of body composition measure-ments in small animals, using a high-resolution DXA system. The technique can be used for testing the efficacy of drugs in small animal models, for muta-genesis screens, and for the phenotypic characterization of transgenic mice.

  7. Small animal radiotherapy research platforms

    Energy Technology Data Exchange (ETDEWEB)

    Verhaegen, Frank; Granton, Patrick [Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Tryggestad, Erik, E-mail: frank.verhaegen@maastro.nl [Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD 21231 (United States)

    2011-06-21

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research. (topical review)

  8. Small animal radiotherapy research platforms

    Science.gov (United States)

    Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik

    2011-06-01

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research.

  9. Small animal radiotherapy research platforms

    International Nuclear Information System (INIS)

    Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik

    2011-01-01

    Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research. (topical review)

  10. Small animals bone density and morphometry analysis with a dual energy X-rays absorptiometry bone densitometer using a 2D digital radiographic detector; Analyse de la densite osseuse et de la morphometrie de petits animaux avec un osteodensitometre bi-energie utilisant un capteur 2D de radiographie numerique

    Energy Technology Data Exchange (ETDEWEB)

    Boudousq, V. [Centre Hospitalier Universitaire de Nimes, 30 (France); Bordy, T.; Gonon, G.; Dinten, J.M. [CEA Grenoble (DTBS/STD), Lab. d' Electronique et de Technologie de l' Informatique, LETI, 38 (France)

    2004-07-01

    LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. In previous papers, technical principles and patients' Bone Mineral Density (BMD) measurement performances were presented. Bone densitometers are also used on small animals for drug development. In this presentation, we show how LEXXOS can be adapted for small animals' examinations and evaluate its performances. At first, in order to take advantage of the whole area of the 20 x 20 cm{sup 2} digital radiographic detector, it has been made profit of X-Rays magnification by adapting the geometrical configuration. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the averaged total body BMD has been measured. This evaluation shows that the right order of BMD magnitude is obtained and, as expected, BMD increases on two sets until a period around puberty and the ovariectomized set presents a significant decrease after. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing useful complementary information on bone morphometry and architecture. This study shows that LEXXOS cone beam bone densitometer provides simultaneously useful quantitative and qualitative information for analysis of bone evolution on small animals. In the future, same system architecture and processing methodology can be used with higher resolution detectors in order to refine information on bone architecture. (authors)

  11. Neurological examination in small animals

    Directory of Open Access Journals (Sweden)

    Viktor Paluš

    2014-03-01

    Full Text Available This clinical review about the neurological examination in small animals describes the basics about the first steps of investigation when dealing with neurological patients. The knowledge of how to perform the neurological examination is important however more important is how to correctly interpret these performed tests. A step-by-step approach is mandatory and examiners should master the order and the style of performing these tests. Neurological conditions can be sometimes very distressing for owners and for pets that might not be the most cooperating. The role of a veterinary surgeon, as a professional, is therefore to collect the most relevant history, to examine a patient in a professional manner and to give to owners an educated opinion about the further treatment and prognosis. However neurological examinations might look challenging for many. But it is only the clinical application of neuroanatomy and neurophysiology to an every-day situation for practicing veterinarians and it does not require any specific in-to-depth knowledge. This clinical review is aimed not only to provide the information on how to perform the neurological examination but it is also aimed to appeal on veterinarians to challenge their daily routine and to start practicing on neurologically normal patients. This is the best and only way to differentiate between the normal and abnormal in a real situation.

  12. Small animal imaging. Basics and practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, Fabian [Aachen Univ. (RWTH) (Germany). Chair of Experimental Molecular Imaging; Pichler, Bernd J. (eds.) [Tuebingen Univ. (Germany). Lab. for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation

    2011-07-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  13. Small animal imaging. Basics and practical guide

    International Nuclear Information System (INIS)

    Kiessling, Fabian; Pichler, Bernd J.

    2011-01-01

    Small animal imaging has been recognized as an important tool in preclinical research. Nevertheless, the results of non-invasive imaging are often disappointing owing to choice of a suboptimal imaging modality and/or shortcomings in study design, experimental setup, and data evaluation. This textbook is a practical guide to the use of non-invasive imaging in preclinical research. Each of the available imaging modalities is discussed in detail, with the assistance of numerous informative illustrations. In addition, many useful hints are provided on the installation of a small animal unit, study planning, animal handling, and the cost-effective performance of small animal imaging. Cross-calibration methods, data postprocessing, and special imaging applications are also considered in depth. This is the first book to cover all the practical basics in small animal imaging, and it will prove an invaluable aid for researchers, students, and technicians. (orig.)

  14. Antimicrobial stewardship in small animal veterinary practice

    DEFF Research Database (Denmark)

    Guardabassi, Luca; Prescott, John F

    2015-01-01

    Despite the increasing recognition of the critical role for antimicrobial stewardship in preventing the spread of multidrug-resistant bacteria, examples of effective antimicrobial stewardship programs are rare in small animal veterinary practice. This article highlights the basic requirements...

  15. Thermoacoustic Molecular Imaging of Small Animals

    Directory of Open Access Journals (Sweden)

    Robert A. Kruger

    2003-04-01

    Full Text Available We have designed, constructed, and tested a thermoacoustic computed tomography (TCT scanner for imaging optical absorption in small animals in three dimensions. The device utilizes pulsed laser irradiation (680–1064 nm and a unique, 128-element transducer array. We quantified the isotropic spatial resolution of this scanner to be 0.35 mm. We describe a dual-wavelength subtraction technique for isolating optical dyes with TCT. Phantom experiments demonstrate that we can detect 5 fmol of a near-infrared dye (indocyanine green, ICG in a 1-ML volume using dual-wavelength subtraction. Initial TCT imaging in phantoms and in two sacrificed mice suggests that three-dimensional, optical absorption patterns in small animals can be detected with an order of magnitude better spatial resolution and an order of magnitude better low-contrast detectability in small animals when compared to fluorescence imaging or diffusion optical tomography.

  16. Advanced Small Animal Conformal Radiation Therapy Device.

    Science.gov (United States)

    Sharma, Sunil; Narayanasamy, Ganesh; Przybyla, Beata; Webber, Jessica; Boerma, Marjan; Clarkson, Richard; Moros, Eduardo G; Corry, Peter M; Griffin, Robert J

    2017-02-01

    We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.

  17. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  18. GPR Imaging of Prehistoric Animal Bone-beds

    Science.gov (United States)

    Schneider, Blair Benson

    This research investigates the detection capabilities of Ground-penetrating radar for imaging prehistoric animal bone-beds. The first step of this investigation was to determine the dielectric properties of modern animal bone as a proxy for applying non-invasive ground-penetrating radar (GPR) for detecting prehistoric animal remains. Over 90 thin section samples were cut from four different modern faunal skeleton remains: bison, cow, deer, and elk. One sample of prehistoric mammoth core was also analyzed. Sample dielectric properties (relative permittivity, loss factor, and loss-tangent values) were measured with an impedance analyzer over frequencies ranging from 10 MHz to 1 GHz. The results reveal statistically significant dielectric-property differences among different animal fauna, as well as variation as a function of frequency. The measured sample permittivity values were then compared to modeled sample permittivity values using common dielectric-mixing models. The dielectric mixing models were used to report out new reported values of dry bone mineral of 3-5 in the frequency range of 10 MHz to 1 GHz. The second half of this research collected controlled GPR experiments over a sandbox containing buried bison bone elements to evaluate GPR detection capabilities of buried animal bone. The results of the controlled GPR sandbox tests were then compared to numerical models in order to predict the ability of GPR to detect buried animal bone given a variety of different depositional factors, the size and orientation of the bone target and the degree of bone weathering. The radar profiles show that GPR is an effective method for imaging the horizontal and vertical extent of buried animal bone. However, increased bone weathering and increased bone dip were both found to affect GPR reflection signal strength. Finally, the controlled sandbox experiments were also utilized to investigate the impact of survey design for imaging buried animal bone. In particular, the

  19. Osteoporotic Animal Models of Bone Healing: Advantages and Pitfalls.

    Science.gov (United States)

    Calciolari, Elena; Donos, Nikolaos; Mardas, Nikos

    2017-10-01

    The aim of this review was to summarize the advantages and pitfalls of the available osteoporotic animal models of bone healing. A thorough literature search was performed in MEDLINE via OVID and EMBASE to identify animal studies investigating the effect of experimental osteoporosis on bone healing and bone regeneration. The osteotomy model in the proximal tibia is the most popular osseous defect model to study the bone healing process in osteoporotic-like conditions, although other well-characterized models, such as the post-extraction model, might be taken into consideration by future studies. The regenerative potential of osteoporotic bone and its response to biomaterials/regenerative techniques has not been clarified yet, and the critical size defect model might be an appropriate tool to serve this purpose. Since an ideal animal model for simulating osteoporosis does not exist, the type of bone remodeling, the animal lifespan, the age of peak bone mass, and the economic and ethical implications should be considered in our selection process. Furthermore, the influence of animal species, sex, age, and strain on the outcome measurement should be taken into account. In order to make future studies meaningful, standardized international guidelines for osteoporotic animal models of bone healing need to be set up.

  20. Clinical aspects of toxoplasmosis in small animal

    Directory of Open Access Journals (Sweden)

    André Luiz Baptista Galvão

    2014-02-01

    Full Text Available Toxoplasmosis, a zoonosis of worldwide distribution, has importance in human and veterinary medicine. Animals can be direct or indirect source of infection to man, and this intermediate host, the disease may be responsible for encephalitis and deaths due to congenital form as coinfection in neonates and patients with acquired immunodeficiency syndrome. The man and animals can acquire the disease by eating undercooked meat or cures, infected with tissue cysts, as well as food and water contaminated with oocysts. Iatrogenic, such as, blood transfusion and organ transplantation are other less frequent routes of transmission. The causative agent of this disease is Toxoplasma gondii, a protozoan obligate intracellular coccidian. In small animals, the infection has been reported in several countries, promoting varied clinical manifestations and uncommon but severe and fatal, which is a challenge in the clinical diagnosis of small animals, especially when the nervous system involvement. Thus, constitute the purpose of this review address the participation of small animals in the spread of the disease, clinical aspects related to it, as well as discuss methods of diagnosis, therapeutic measures, prophylaxis and control of this disease.

  1. Small Animal Models for Evaluating Filovirus Countermeasures.

    Science.gov (United States)

    Banadyga, Logan; Wong, Gary; Qiu, Xiangguo

    2018-05-11

    The development of novel therapeutics and vaccines to treat or prevent disease caused by filoviruses, such as Ebola and Marburg viruses, depends on the availability of animal models that faithfully recapitulate clinical hallmarks of disease as it is observed in humans. In particular, small animal models (such as mice and guinea pigs) are historically and frequently used for the primary evaluation of antiviral countermeasures, prior to testing in nonhuman primates, which represent the gold-standard filovirus animal model. In the past several years, however, the filovirus field has witnessed the continued refinement of the mouse and guinea pig models of disease, as well as the introduction of the hamster and ferret models. We now have small animal models for most human-pathogenic filoviruses, many of which are susceptible to wild type virus and demonstrate key features of disease, including robust virus replication, coagulopathy, and immune system dysfunction. Although none of these small animal model systems perfectly recapitulates Ebola virus disease or Marburg virus disease on its own, collectively they offer a nearly complete set of tools in which to carry out the preclinical development of novel antiviral drugs.

  2. Advances in Small Animal Imaging Systems

    International Nuclear Information System (INIS)

    Loudos, George K.

    2007-01-01

    The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided

  3. Animal models for bone tissue engineering and modelling disease

    Science.gov (United States)

    Griffin, Michelle

    2018-01-01

    ABSTRACT Tissue engineering and its clinical application, regenerative medicine, are instructing multiple approaches to aid in replacing bone loss after defects caused by trauma or cancer. In such cases, bone formation can be guided by engineered biodegradable and nonbiodegradable scaffolds with clearly defined architectural and mechanical properties informed by evidence-based research. With the ever-increasing expansion of bone tissue engineering and the pioneering research conducted to date, preclinical models are becoming a necessity to allow the engineered products to be translated to the clinic. In addition to creating smart bone scaffolds to mitigate bone loss, the field of tissue engineering and regenerative medicine is exploring methods to treat primary and secondary bone malignancies by creating models that mimic the clinical disease manifestation. This Review gives an overview of the preclinical testing in animal models used to evaluate bone regeneration concepts. Immunosuppressed rodent models have shown to be successful in mimicking bone malignancy via the implantation of human-derived cancer cells, whereas large animal models, including pigs, sheep and goats, are being used to provide an insight into bone formation and the effectiveness of scaffolds in induced tibial or femoral defects, providing clinically relevant similarity to human cases. Despite the recent progress, the successful translation of bone regeneration concepts from the bench to the bedside is rooted in the efforts of different research groups to standardise and validate the preclinical models for bone tissue engineering approaches. PMID:29685995

  4. Evaluation of photon-absorptiometry for determination of bone mineral content in experimental animals

    International Nuclear Information System (INIS)

    Krasznai, I.; Szathmary, M.; Horvath, Cs.; Hollo, G.; Fabu, G.

    1994-01-01

    Instruments commonly used for determination of bone mineral content in human were evaluated for their use in small laboratory animals. By measuring bone phantoms and rat femurs in vitro, authors found 0.015 and 0.034 g/cm sensitivity for (SPA) and (DEXA) methods, respectively. High reproducibility was obtained, with values of relative standard deviations being <2 and approximately 4% for SPA and DEXA, respectively. Both techniques were found suitable for determination of bone mineral content of laboratory animals, but DEXA is suggested as the preferred method for evaluations under in vivo circumstances. (N.T.)

  5. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  6. Effects of Spaceflight on Bone: The Rat as an Animal Model for Human Bone Loss

    Science.gov (United States)

    Halloran, B.; Weider, T.; Morey-Holton, E.

    1999-01-01

    The loss of weight bearing during spaceflight results in osteopenia in humans. Decrements in bone mineral reach 3-10% after as little as 75-184 days in space. Loss of bone mineral during flight decreases bone strength and increases fracture risk. The mechanisms responsible for, and the factors contributing to, the changes in bone induced by spaceflight are poorly understood. The rat has been widely used as an animal model for human bone loss during spaceflight. Despite its potential usefulness, the results of bone studies performed in the rat in space have been inconsistent. In some flights bone formation is decreased and cancellous bone volume reduced, while in others no significant changes in bone occur. In June of 1996 Drs. T. Wronski, S. Miller and myself participated in a flight experiment (STS 78) to examine the effects of glucocorticoids on bone during weightlessness. Technically the 17 day flight experiment was flawless. The results, however, were surprising. Cancellous bone volume and osteoblast surface in the proximal tibial metaphysis were the same in flight and ground-based control rats. Normal levels of cancellous bone mass and bone formation were also detected in the lumbar vertebrae and femoral neck of flight rats. Furthermore, periosteal bone formation rate was found to be identical in flight and ground-based control rats. Spaceflight had little or no effect on bone metabolism! These results prompted us to carefully review the changes in bone observed in, and the flight conditions of previous spaceflight missions.

  7. Determination of processed animal proteins, including meat and bone meal, in animal feed

    NARCIS (Netherlands)

    Gizzi, G.; Holst, von C.; Baeten, V.; Berben, G.; Raamsdonk, van L.W.D.

    2004-01-01

    The presence of processed animal proteins (PAP), including meat and bone meal (MBM) from various species, in animal feed was investigated. It was demonstrated that microscopy is the most reliable method for enforcing the current total MBM ban in the European Uion (EU). It was shown that near

  8. Modality comparison for small animal radiotherapy: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova, Magdalena, E-mail: bazalova@stanford.edu; Nelson, Geoff; Noll, John M.; Graves, Edward E. [Department of Radiation Oncology, Molecular Imaging Program at Stanford, Stanford University, Stanford, California 94305 (United States)

    2014-01-15

    Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by

  9. Nitrogen and carbon isotopic composition of bone collagen from marine and terrestrial animals

    International Nuclear Information System (INIS)

    Schoeninger, M.J.; DeNiro, M.J.

    1984-01-01

    The stable nitrogen and carbon isotope ratios of bone collagen prepared from more than 100 animals representing 66 species of birds, fish, and mammals are presented. The delta 15 N values of bone collagen from animals that fed exclusively in the marine environment are, on average, 9 per mille more positive than those from animals that fed exclusively in the terrestrial environment: ranges for the two groups overlap by less than 1 per mille. Bone collagen delta 15 N values also serve to separate marine fish from the small number of freshwater fish we analyzed. The bone collagen delta 15 N values of birds and fish that spent part of their life cycles feeding in the marine environment and part in the freshwater environment are intermediate between those of animals that fed exclusively in one or the other system. Further, animals that fed at successive trophic levels in the marine and terrestrial environment are separated, on average, by a 3 per mille difference in the delta 15 N values of their bone collagen. Results are given and discussed. (author)

  10. Paleopathological analysis of changes on animal bones originating from archaeological sites Caricin Grad and Studenica Monastery

    Directory of Open Access Journals (Sweden)

    Marković Nemanja

    2014-01-01

    Full Text Available This work presents the estimation of incidence and analysis of paleopathological changes on skeletal remains of the animals from archaeological sites Caricin Grad and Studenica Monastery. Moreover, there has been carried out the assessment of the skeletal elements, as well as taxonomic and age determination. The total of 2595 bones or bone fragments were examined. In 22 specimens there were noticed various abnormal skeletal changes in following animal species: cattle, sheep, goats, pigs, horses, donkeys and camels. Pathological changes were noticed on the teeth, mandibles, joints of long bones and phalanxes. By macroscopic analysis of these acquired pathological changes on bones of the animals, there was determined that the observed lesions had had proliferative, hypertrophic and chronic character. Proliferative changes on the bones of the cattle, horses, donkeys and camels point out to the fact that these animals were used for towing and/or load carrying. Identified diseases of oral cavity in small ruminants point out to improper and inadequate nutrition of these animals in the past.

  11. Blended learning in the small animal clinic

    DEFF Research Database (Denmark)

    Langebæk, Rikke

    2011-01-01

    At the Department of Small Animal Clinical Sciences, Basic Surgical Skills are taught in groups of 30-35 students in the first year of the master program (4th year students). The eight day course is an example of ‘blended learning’ in which students use our e-learning-material (Step 1) to prepare...... for the practical part of the course (Step 2, 3 and 4). From their home computers, students log on to the e-learning platform of Copenhagen University: https://absalon.ku.dk and go to the Basic Surgical Skills course, which consist of a line of chapters concerning a variety of surgical subjects. Each subject...... the implementation of these new teaching methods (e-learning and Skills Lab), teachers have ascertained a more satisfactory level of preparation, students that seem more focused and live-animal surgery that is conducted at a more ‘professional’ level than before. Finally, our research in this field shows...

  12. Theoretical considerations on maximum running speeds for large and small animals.

    Science.gov (United States)

    Fuentes, Mauricio A

    2016-02-07

    Mechanical equations for fast running speeds are presented and analyzed. One of the equations and its associated model predict that animals tend to experience larger mechanical stresses in their limbs (muscles, tendons and bones) as a result of larger stride lengths, suggesting a structural restriction entailing the existence of an absolute maximum possible stride length. The consequence for big animals is that an increasingly larger body mass implies decreasing maximal speeds, given that the stride frequency generally decreases for increasingly larger animals. Another restriction, acting on small animals, is discussed only in preliminary terms, but it seems safe to assume from previous studies that for a given range of body masses of small animals, those which are bigger are faster. The difference between speed scaling trends for large and small animals implies the existence of a range of intermediate body masses corresponding to the fastest animals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. A cognitive network for oracle bone characters related to animals

    Science.gov (United States)

    Dress, Andreas; Grünewald, Stefan; Zeng, Zhenbing

    2016-01-01

    In this paper, we present an analysis of oracle bone characters for animals from a “cognitive” point of view. After some general remarks on oracle-bone characters presented in Sec. 1 and a short outline of the paper in Sec. 2, we collect various oracle-bone characters for animals from published resources in Sec. 3. In the next section, we begin analyzing a group of 60 ancient animal characters from www.zdic.net, a highly acclaimed internet dictionary of Chinese characters that is strictly based on historical sources, and introduce five categories of specific features regarding their (graphical) structure that will be used in Sec. 5 to associate corresponding feature vectors to these characters. In Sec. 6, these feature vectors will be used to investigate their dissimilarity in terms of a family of parameterized distance measures. And in the last section, we apply the SplitsTree method as encoded in the NeighborNet algorithms to construct a corresponding family of dissimilarity-based networks with the intention of elucidating how the ancient Chinese might have perceived the “animal world” in the late bronze age and to demonstrate that these pictographs reflect an intuitive understanding of this world and its inherent structure that predates its classification in the oldest surviving Chinese encyclopedia from approximately the third century BC, the Er Ya, as well as similar classification systems in the West by one to two millennia. We also present an English dictionary of 70 oracle bone characters for animals in Appendix A. In Appendix B, we list various variants of animal characters that were published in the Jia Gu Wen Bian (cf. 甲骨文编, A Complete Collection of Oracle Bone Characters, edited by the Institute of Archaeology of the Chinese Academy of Social Sciences, published by the Zhonghua Book Company in 1965). We recall the frequencies of the 521 most frequent oracle bone characters in Appendix C as reported in [T. Chen, Yin-Shang Jiaguwen Zixing

  14. Enclosure for small animals during awake animal imaging

    Science.gov (United States)

    Goddard, Jr., James S

    2013-11-26

    An enclosure or burrow restrains an awake animal during an imaging procedure. A tubular body, made from a radiolucent material that does not attenuate x-rays or gamma rays, accepts an awake animal. A proximal end of the body includes an attachment surface that corresponds to an attachment surface of an optically transparent and optically uniform window. An anti-reflective coating may be applied to an inner surface, an outer surface, or both surfaces of the window. Since the window is a separate element of the enclosure and it is not integrally formed as part of the body, it can be made with optically uniform thickness properties for improved motion tracking of markers on the animal with a camera during the imaging procedure. The motion tracking information is then used to compensate for animal movement in the image.

  15. Coupler for surgery on small animals

    Science.gov (United States)

    Johnson, J. E., Jr.; Swartz, P. F.

    1979-01-01

    Minicoupler simplifies exchange of fluids with organs of laboratory animals enabling one person to perform surgery on experimental animals such as rats and mice. Innovation eliminates obstructing hands and instruments from areas of surgery.

  16. Animal Models for Evaluation of Bone Implants and Devices: Comparative Bone Structure and Common Model Uses.

    Science.gov (United States)

    Wancket, L M

    2015-09-01

    Bone implants and devices are a rapidly growing field within biomedical research, and implants have the potential to significantly improve human and animal health. Animal models play a key role in initial product development and are important components of nonclinical data included in applications for regulatory approval. Pathologists are increasingly being asked to evaluate these models at the initial developmental and nonclinical biocompatibility testing stages, and it is important to understand the relative merits and deficiencies of various species when evaluating a new material or device. This article summarizes characteristics of the most commonly used species in studies of bone implant materials, including detailed information about the relevance of a particular model to human bone physiology and pathology. Species reviewed include mice, rats, rabbits, guinea pigs, dogs, sheep, goats, and nonhuman primates. Ultimately, a comprehensive understanding of the benefits and limitations of different model species will aid in rigorously evaluating a novel bone implant material or device. © The Author(s) 2015.

  17. Radioactive contamination of animal bones by 90Sr

    International Nuclear Information System (INIS)

    Franic, Z.; Maracic, M.

    1996-01-01

    90 Sr has been regarded as the fission product of great potential hazard to living things because of the unique combination of its 28-y long half-life, the very energetic beta particle of its 90 Y daughter, and its general resemblance to calcium in metabolic processes. Therefore, due to chemical and metabolic similarity to calcium, bone is the critical organ for radioactive isotopes of strontium. The Department of Radiation Protection of the Institute for Medical Research and Occupational Health, has carried out radioactivity measurements of the food chain as part of an extended monitoring programme, since 1963. This includes systematic, long-term measurements of 90 Sr in long bones of some domestic animals (cows and pigs) while data on lamb bones exist for the very beginning of the investigated period, and for the period after the Chernobyl nuclear accident

  18. Calcium isotope ratios in animal and human bone

    Science.gov (United States)

    Reynard, L. M.; Henderson, G. M.; Hedges, R. E. M.

    2010-07-01

    Calcium isotopes in tissues are thought to be influenced by an individual's diet, reflecting parameters such as trophic level and dairy consumption, but this has not been carefully assessed. We report the calcium isotope ratios (δ 44/42Ca) of modern and archaeological animal and human bone ( n = 216). Modern sheep raised at the same location show 0.14 ± 0.08‰ higher δ 44/42Ca in females than in males, which we attribute to lactation by the ewes. In the archaeological bone samples the calcium isotope ratios of the herbivorous fauna vary by location. At a single site, the archaeological fauna do not show a trophic level effect. Humans have lower δ 44/42Ca than the mean site fauna by 0.22 ± 0.22‰, and the humans have a greater δ 44/42Ca range than the animals. No effect of sex or age on the calcium isotope ratios was found, and intra-individual skeletal δ 44/42Ca variability is negligible. We rule out dairy consumption as the main cause of the lower human δ 44/42Ca, based on results from sites pre-dating animal domestication and dairy availability, and suggest instead that individual physiology and calcium intake may be important in determining bone calcium isotope ratios.

  19. Bone augmentation for cancellous bone- development of a new animal model

    Science.gov (United States)

    2013-01-01

    Background Reproducible and suitable animal models are required for in vivo experiments to investigate new biodegradable and osteoinductive biomaterials for augmentation of bones at risk for osteoporotic fractures. Sheep have especially been used as a model for the human spine due to their size and similar bone metabolism. However, although sheep and human vertebral bodies have similar biomechanical characteristics, the shape of the vertebral bodies, the size of the transverse processes, and the different orientation of the facet joints of sheep are quite different from those of humans making the surgical approach complicated and unpredictable. Therefore, an adequate and safe animal model for bone augmentation was developed using a standardized femoral and tibia augmentation site in sheep. Methods The cancellous bone of the distal femur and proximal tibia were chosen as injection sites with the surgical approach via the medial aspects of the femoral condyle and proximal tibia metaphysis (n = 4 injection sites). For reproducible drilling and injection in a given direction and length, a custom-made c-shaped aiming device was designed. Exact positioning of the aiming device and needle positioning within the intertrabecular space of the intact bone could be validated in a predictable and standardized fashion using fluoroscopy. After sacrifice, bone cylinders (∅ 32 mm) were harvested throughout the tibia and femur by means of a diamond-coated core drill, which was especially developed to harvest the injected bone area exactly. Thereafter, the extracted bone cylinders were processed as non-decalcified specimens for μCT analysis, histomorphometry, histology, and fluorescence evaluation. Results The aiming device could be easily placed in 63 sheep and assured a reproducible, standardized injection area. In four sheep, cardiovascular complications occurred during surgery and pulmonary embolism was detected by computed tomography post surgery in all of these animals

  20. Re-evaluation of bone pain in patients with type 1 Gaucher disease suggests that bone crises occur in small bones as well as long bones.

    Science.gov (United States)

    Baris, Hagit N; Weisz Hubshman, Monika; Bar-Sever, Zvi; Kornreich, Liora; Shkalim Zemer, Vered; Cohen, Ian J

    2016-09-01

    Bone crises in type 1 Gaucher disease are reported in long bones and occasionally in weight bearing bones and other bones, but rarely in small bones of the hands and feet. We retrospectively examined the incidence of bone pain in patients followed at the Rabin Medical Center, Israel, before and following the initiation of enzyme replacement therapy (ERT) and evaluated them for bone crises. Of 100 type I Gaucher disease patients, 30 (30%) experienced one or more bone crises. Small bone crises represented 31.5% of all bone crises and were always preceded by crises in other bones. While the incidence of long bone crises reduced after the initiation of ERT, small bone crises increased. Almost 60% of patients with bone crises were of the N370S/84GG genotype suggesting a greater susceptibility of N370S/84GG patients to severe bone complications. These patients also underwent the greatest number of splenectomies (70.6% of splenectomised patients). Splenectomised patients showed a trend towards increased long and small bone crises after surgery. Active investigation of acute pain in the hands and feet in patients in our cohort has revealed a high incidence of small bone crises. Physicians should consider imaging studies to investigate unexplained pain in these areas. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Improved dopamine transporter binding activity after bone marrow mesenchymal stem cell transplantation in a rat model of Parkinson's disease: small animal positron emission tomography study with F-18 FP-CIT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Bok-Nam; Lee, Kwanjae; An, Young-Sil [School of Medicine, Ajou University, Department of Nuclear Medicine and Molecular Imaging, Woncheon-dong, Yeongtong-gu, Gyeonggi-do, Suwon (Korea, Republic of); Kim, Jang-Hee; Park, So Hyun [Ajou University School of Medicine, Department of Pathology, Suwon (Korea, Republic of)

    2015-05-01

    We evaluated the effects of bone marrow-derived mesenchymal stem cells (BMSCs) in a model of Parkinson's disease (PD) using serial F-18 fluoropropylcarbomethoxyiodophenylnortropane (FP-CIT) PET. Hemiparkinsonian rats were treated with intravenously injected BMSCs, and animals without stem cell therapy were used as the controls. Serial FP-CIT PET was performed after therapy. The ratio of FP-CIT uptake in the lesion side to uptake in the normal side was measured. The changes in FP-CIT uptake were also analyzed using SPM. Behavioural and histological changes were observed using the rotational test and tyrosine hydroxylase (TH)-reactive cells. FP-CIT uptake ratio was significantly different in the BMSCs treated group (n = 28) at each time point. In contrast, there was no difference in the ratio in control rats (n = 25) at any time point. SPM analysis also revealed that dopamine transporter binding activity was enhanced in the right basal ganglia area in only the BMSC therapy group. In addition, rats that received BMSC therapy also exhibited significantly improved rotational behaviour and preservation of TH-positive neurons compared to controls. The therapeutic effect of intravenously injected BMSCs in a rat model of PD was confirmed by dopamine transporter PET imaging, rotational functional studies, and histopathological evaluation. (orig.)

  2. Improved dopamine transporter binding activity after bone marrow mesenchymal stem cell transplantation in a rat model of Parkinson's disease: small animal positron emission tomography study with F-18 FP-CIT

    International Nuclear Information System (INIS)

    Park, Bok-Nam; Lee, Kwanjae; An, Young-Sil; Kim, Jang-Hee; Park, So Hyun

    2015-01-01

    We evaluated the effects of bone marrow-derived mesenchymal stem cells (BMSCs) in a model of Parkinson's disease (PD) using serial F-18 fluoropropylcarbomethoxyiodophenylnortropane (FP-CIT) PET. Hemiparkinsonian rats were treated with intravenously injected BMSCs, and animals without stem cell therapy were used as the controls. Serial FP-CIT PET was performed after therapy. The ratio of FP-CIT uptake in the lesion side to uptake in the normal side was measured. The changes in FP-CIT uptake were also analyzed using SPM. Behavioural and histological changes were observed using the rotational test and tyrosine hydroxylase (TH)-reactive cells. FP-CIT uptake ratio was significantly different in the BMSCs treated group (n = 28) at each time point. In contrast, there was no difference in the ratio in control rats (n = 25) at any time point. SPM analysis also revealed that dopamine transporter binding activity was enhanced in the right basal ganglia area in only the BMSC therapy group. In addition, rats that received BMSC therapy also exhibited significantly improved rotational behaviour and preservation of TH-positive neurons compared to controls. The therapeutic effect of intravenously injected BMSCs in a rat model of PD was confirmed by dopamine transporter PET imaging, rotational functional studies, and histopathological evaluation. (orig.)

  3. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  4. Prevalence and pattern of small animal orthopaedic conditions at ...

    African Journals Online (AJOL)

    Small animal orthopaedic case records of a 20-year period were surveyed to obtain the prevalence and pattern of orthopaedic conditions presented to the Veterinary Teaching Hospital (VTH), University of Ibadan, Nigeria, with the objective of providing data for planning on small animal healthcare facilities, policy ...

  5. [Comparation on Haversian system between human and animal bones by imaging analysis].

    Science.gov (United States)

    Lu, Hui-Ling; Zheng, Jing; Yao, Ya-Nan; Chen, Sen; Wang, Hui-Pin; Chen, Li-Xian; Guo, Jing-Yuan

    2006-04-01

    To explore the differences in Haversian system between human and animal bones through imaging analysis and morphology description. Thirty-five slices grinding from human being as well as dog, pig, cow and sheep bones were observed to compare their structure, then were analysed with the researchful microscope. Plexiform bone or oeston band was not found in human bones; There were significant differences in the shape, size, location, density of Haversian system, between human and animal bones. The amount of Haversian lamella and diameter of central canal in human were the biggest; Significant differences in the central canal diameter and total area percentage between human and animal bones were shown by imaging analysis. (1) Plexiform bone and osteon band could be the exclusive index in human bone; (2) There were significant differences in the structure of Haversian system between human and animal bones; (3) The percentage of central canals total area was valuable in species identification through imaging analysis.

  6. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. The Japanese Medakafish (Oryzias latipes) as Animal Model for Space-related Bone Research

    Science.gov (United States)

    Renn, J.; Schaedel, M.; Elmasri, H.; Wagner, T.; Goerlich, R.; Furutani-Seiki, M.; Kondoh, H.; Schartl, M.; Winkler, C.

    Long-term space flight leads to bone loss due to reduced mechanical load. Animal models are needed to support the analysis of the underlying mechanisms at the molecular and cellular level that are presently largely unclear. For this, small laboratory fish offer many experimental advantages as in vivo models to study disease related processes. They produce large numbers of completely transparent embryos, are easy to keep under laboratory and space conditions and have relatively compact genomes. We are using the Japanese Medaka to characterize the genetic networks regulating bone formation and to study bone formation and remodeling under microgravity. We showed that despite the large evolutionary distance many known factors regulating bone formation are conserved between fish and humans. This includes osteoprotegerin (opg), a key regulator of bone resorption that is altered at the transcriptional level by simulated microgravity in mammals in vitro (Kanematsu et al., Bone 30, 2002). To monitor, how opg is regulated by altered gravity in vivo in fish and how fish react to microgravity, we isolated the Medaka opg regulatory region and produced transgenic fish that carry the green fluorescent protein reporter under the control of the Medaka opg promoter. This model will be useful to monitor gravity-induced changes at the molecular level in vivo. Fish also provide the opportunity to identify novel genes involved in bone formation by using large-scale mutagenesis screens. We have characterized several lines of mutant fish subjected to ENU mutagenesis that show morphological defects in the formation of the bone precursor cell compartment of the axial skeleton, the sclerotome. Using this genetic approach, the identification of the mutated genes is expected to reveal novel components of the genetic cascades that regulate bone formation. In an attempt to identify genes specifically expressed in the sclerotome in Medaka, we identified and characterized dmrt2, a gene that so far

  8. Biological effects of high-strength electric fields on small laboratory animals. Interim report, March 1, 1978-September 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, R.D.; Anderson, L.E.; Kaune, W.T.

    1979-12-01

    Progress is described on a project assessing the biological effects of 60-Hz electric fields on small laboratory animals (rats and mice). The report includes sections on hematology and seram chemistry, immunology, pathology, metabolism, bone growth, endocrinology, cardiovascular function, neurophysiology, growth and development, and animal behavior. (ACR)

  9. Influence of different methods of internal bone fixation on characteristics of bone callus in experimental animals

    Directory of Open Access Journals (Sweden)

    Gajdobranski Đorđe

    2014-01-01

    Full Text Available Introduction. Correct choice of osteosynthesis method is a very important factor in providing the optimal conditions for appropriate healing of the fracture. There are still disagreements about the method of stabilization of some long bone fractures. Critically observed, no method of fracture fixation is ideal. Each osteosynthesis method has both advantages and weaknesses. Objective. The objective of this study was to compare the results of the experimental application of three different internal fixation methods: plate fixation, intramedullary nail fixation and self-dynamisable internal fixator (SIF. Methods. A series of 30 animals were used (Lepus cuniculus as experimental animals, divided into three groups of ten animals each. Femoral diaphysis of each animal was osteotomized and fixed with one of three implants. Ten weeks later all animals were sacrificed and each specimen underwent histological and biomechanical testing. Results. Histology showed that the healing process with SIF was more complete and bone callus was more mature in comparison to other two methods. During biomechanical investigation (computerized bending stress test, it was documented with high statistical significance that using SIF led to stronger healing ten weeks after the operation. Conclusion. According to the results obtained in this study, it can be concluded that SIF is a suitable method for fracture treatment.

  10. Animal models of maternal nutrition and altered offspring bone structure – Bone development across the lifecourse

    Directory of Open Access Journals (Sweden)

    SA Lanham

    2011-11-01

    Full Text Available It is widely accepted that the likelihood of offspring developing heart disease, stroke, or diabetes in later life, is influenced by the their in utero environment and maternal nutrition. There is increasing epidemiological evidence that osteoporosis in the offspring may also be influenced by the mother’s nutrition during pregnancy. This review provides evidence from a range of animal models that supports the epidemiological data; suggesting that lifelong bone development and growth in offspring is determined during gestation.

  11. A new small-animal model for the study of acquired heterotopic ossification after hip surgery.

    Science.gov (United States)

    Anthonissen, Joris; Ossendorf, Christian; Hock, Johanna Lisa; Ritz, Ulrike; Hofmann, Alexander; Rommens, Pol Maria

    2015-01-01

    Heterotopic ossification (HO)--the formation of bone in soft tissues--is a frequent problem after surgery of the hip and pelvis, but little is known about its underlying pathogenic mechanisms. It is vital to study the underlying pathogenesis in animal models to develop and evaluate new prophylactic regimens directed against HO. However, previously developed small-animal models for the study of HO imitate neither surgery nor trauma-mechanisms that potentially cause HO. Hence, the goal of this study was to develop a novel small-animal model imitating hip surgery that can reliably produce HO. Twenty male Wistar rats were subjected to surgery of the right hip during which the femoral canal was reamed in three steps up to 2 mm, and a muscle lesion was made. Twelve weeks after surgery, the amount of heterotopic bone was assessed using micro-computed tomography. Eighteen of 20 animals showed HO around the hip 12 weeks after surgery. The amount of heterotopic bone varied from very small particles up to near ankylosis. A rat model of hip/pelvic surgery that does not use exogenous osteogenic stimulus and can reliably produce HO was developed.

  12. Cortical inactivation by cooling in small animals

    Directory of Open Access Journals (Sweden)

    Ben eCoomber

    2011-06-01

    Full Text Available Reversible inactivation of the cortex by surface cooling is a powerful method for studying the function of a particular area. Implanted cooling cryoloops have been used to study the role of individual cortical areas in auditory processing of awake-behaving cats. Cryoloops have also been used in rodents for reversible inactivation of the cortex, but recently there has been a concern that the cryoloop may also cool non-cortical structures either directly or via the perfusion of blood, cooled as it passed close to the cooling loop. In this study we have confirmed that the loop can inactivate most of the auditory cortex without causing a significant reduction in temperature of the auditory thalamus or other sub-cortical structures. We placed a cryoloop on the surface of the guinea pig cortex, cooled it to 2°C and measured thermal gradients across the neocortical surface. We found that the temperature dropped to 20-24°C among cells within a radius of about 2.5mm away from the loop. This temperature drop was sufficient to reduce activity of most cortical cells and led to the inactivation of almost the entire auditory region. When the temperature of thalamus, midbrain, and middle ear were measured directly during cortical cooling, there was a small drop in temperature (about 4°C but this was not sufficient to directly reduce neural activity. In an effort to visualise the extent of neural inactivation we measured the uptake of thallium ions following an intravenous injection. This confirmed that there was a large reduction of activity across much of the ipsilateral cortex and only a small reduction in subcortical structures.

  13. Technical note - Considerations for MR imaging of small animals

    International Nuclear Information System (INIS)

    Baker, Martin A.

    2011-01-01

    Routine clinical veterinary use of MR scanning is becoming more common. This article addresses the major technical considerations for radiographers performing MR examinations on small animals and provides practical advice for scanning techniques.

  14. Small animal PET and its applications in biomedical research

    International Nuclear Information System (INIS)

    Qiu Feichan

    2004-01-01

    Positron emission tomography (PET) is a nuclear medical imaging technique that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. As the leading technology in nuclear medicine, PET has extended its applications from the clinical field to the study of small laboratory animals. In recent years, the development of new detector technology has dramatically improved the spatial resolution and image quality of small animal PET scanner, which is being used increasingly as a basic tool in modern biomedical research. In particular, small animal PET will play an important role in drug discovery and development, in the study of small animal models of human diseases, in characterizing gene expression and in many other ways. (authors)

  15. Chemical and biomechanical characterization of hyperhomocysteinemic bone disease in an animal model

    Directory of Open Access Journals (Sweden)

    Howell David S

    2003-02-01

    Full Text Available Abstract Background Classical homocystinuria is an autosomal recessive disorder caused by cystathionine β-synthase (CBS deficiency and characterized by distinctive alterations of bone growth and skeletal development. Skeletal changes include a reduction in bone density, making it a potentially attractive model for the study of idiopathic osteoporosis. Methods To investigate this aspect of hyperhomocysteinemia, we supplemented developing chicks (n = 8 with 0.6% dl-homocysteine (hCySH for the first 8 weeks of life in comparison to controls (n = 10, and studied biochemical, biomechanical and morphologic effects of this nutritional intervention. Results hCySH-fed animals grew faster and had longer tibiae at the end of the study. Plasma levels of hCySH, methionine, cystathionine, and inorganic sulfate were higher, but calcium, phosphate, and other indices of osteoblast metabolism were not different. Radiographs of the lower limbs showed generalized osteopenia and accelerated epiphyseal ossification with distinct metaphyseal and suprametaphyseal lucencies similar to those found in human homocystinurics. Although biomechanical testing of the tibiae, including maximal load to failure and bone stiffness, indicated stronger bone, strength was proportional to the increased length and cortical thickness in the hCySH-supplemented group. Bone ash weights and IR-spectroscopy of cortical bone showed no difference in mineral content, but there were higher Ca2+/PO43- and lower Ca2+/CO32- molar ratios than in controls. Mineral crystallization was unchanged. Conclusion In this chick model, hyperhomocysteinemia causes greater radial and longitudinal bone growth, despite normal indices of bone formation. Although there is also evidence for an abnormal matrix and altered bone composition, our finding of normal biomechanical bone strength, once corrected for altered morphometry, suggests that any increase in the risk of long bone fracture in human hyperhomocysteinemic

  16. Investigation of the collagen-mineral-relation in bone with special respect to bone diseases with collagen defects by small-angle X-ray scattering

    International Nuclear Information System (INIS)

    Schreiber, S. A.

    1996-06-01

    Small-angle X-ray scattering (SAXS) was used to study the structure of the collagen/mineral composite of bone in the nanometer range. The most important results were: - In horse radius, the angular distribution of mineral crystals as measured by SAXS agreed well with previous measurements of collagen orientation using circularly polarized light microscopy. This shows that the crystals are parallel to the collagen fibrils. - The effect of sodium fluoride, which stimulates bone formation, and bisphosphonates, which reduce bone resorption, were analyzed. A slight increase in the average thickness of the mineral crystals as well as changes in the structure of the mineral/collagen composite were found in the case of fluoride treated animals. No differences were found between alendronate treated animals and controls. The changes with NaF correlate with bone weakening found in an earlier study with the same animals. - In cortical bone from 9 patients with Osteogenesis Imperfecta (brittle bone disease) the mean thickness of the mineral crystals was found approximately constant around 2.4 nm, while in control bones it constantly increased with age up to about 3.5 nm. In addition, the parallel alignment of the mineral crystals was less in OI-bone than in normal controls. Hence, despite the great variability of this genetic collagen defect, smaller and less well aligned mineral crystals seem to characterize the collagen/mineral composite in OI-bone. (author)

  17. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  18. DXA measurements in Rett syndrome reveal small bones with low bone mass.

    Science.gov (United States)

    Roende, Gitte; Ravn, Kirstine; Fuglsang, Kathrine; Andersen, Henrik; Nielsen, Jytte Bieber; Brøndum-Nielsen, Karen; Jensen, Jens-Erik Beck

    2011-09-01

    Low bone mass is reported in growth-retarded patients harboring mutations in the X-linked methyl-CpG-binding protein 2 (MECP2) gene causing Rett syndrome (RTT). We present the first study addressing both bone mineral density (BMD) and bone size in RTT. Our object was to determine whether patients with RTT do have low BMD when correcting for smaller bones by examination with dual-energy X-ray absorptiometry (DXA). We compared areal BMD (aBMD(spine) and aBMD(total hip) ) and volumetric bone mineral apparent density (vBMAD(spine) and vBMAD(neck) ) in 61 patients and 122 matched healthy controls. Further, spine and hip aBMD and vBMAD of patients were associated with clinical risk factors of low BMD, low-energy fractures, MECP2 mutation groups, and X chromosome inactivation (XCI). Patients with RTT had reduced bone size on the order of 10% and showed lower values of spine and hip aBMD and vBMAD (p bone mass and small bones are evident in RTT, indicating an apparent low-bone-formation phenotype. Copyright © 2011 American Society for Bone and Mineral Research.

  19. Molecular Imaging with Small Animal PET/CT

    DEFF Research Database (Denmark)

    Binderup, T.; El-Ali, H.H.; Skovgaard, D.

    2011-01-01

    is also described. In addition, the non-invasive nature of molecular imaging and the targets of these promising new tracers are attractive for other research areas as well, although these fields are much less explored. We present an example of an interesting research field with the application of small......Small animal positron emission tomography (PET) and computer tomography (CT) is an emerging field in pre-clinical imaging. High quality, state-of-the-art instruments are required for full optimization of the translational value of the small animal studies with PET and CT. However...... in this field of small animal molecular imaging with special emphasis on the targets for tissue characterization in tumor biology such as hypoxia, proliferation and cancer specific over-expression of receptors. The added value of applying CT imaging for anatomical localization and tumor volume measurements...

  20. Scanning small angle X-ray scattering investigations of bone

    International Nuclear Information System (INIS)

    Rinnerthaler, S.

    1998-06-01

    An important characteristic of bone is its strength, which is determined by bone mass, architecture and material quality. From a physical point of view bone is a composite material consisting of an organic matrix (collagen) and of inlets of mineral crystals (hydroxyapatite). These components build up a hierarchical, heterogeneous structure. The size of the mineral crystals lies in the nano-meter range and can be investigated by positionsensitive Small-Angle X-ray Scattering (Scanning-SAXS) in a non-destructive way. The average thickness, the degree and direction of the predominant orientation, as well as some information about shape and arrangement of the mineral crystals were determined in bones of humans, mice, and baboons by Scanning-SAXS with respect to age, bone diseases (osteogenesis imperfecta, pycnodysostosis) or medical treatments (fluoride or alendronate) of osteoporosis. The crystal thickness and the degree of orientation is much smaller in young individuals than in adults and the predominant orientation of the mineral crystals is different in a mixture of bone and mineralized cartilage compared to bone. Further, because position-resolved measurements are now possible, results from Scanning-SAXS measurements could be compared with the results of other position resolved methods. Due to this new feature it was possible, for the first time, to correlate directly 'mottled' bone visible in back-scattered electron imaging with small η-parameters evaluated from SAXS-patterns and the course of the collagen fibers with the predominant orientation of the mineral crystals. Scanning-SAXS proved to be a powerful tool to characterize bone nano-structure. (author)

  1. Acute small bowel obstruction due to chicken bone bezoar

    Directory of Open Access Journals (Sweden)

    Vetpillai P

    2012-12-01

    Full Text Available Preadeepan Vetpillai,1 Ayo Oshowo21CT2 Surgery in General, Charing Cross Hospital, 2Colorectal and Laparoscopic Surgery, Whittington Hospital, London, UKAbstract: Acute intestinal obstruction due to foreign bodies, or bezoar, is a rare occurrence in an adult with a normal intestinal tract. We report an unusual case of a 43-year-old black man with no previous abdominal surgery and no significant medical history who presented with an acute episode of small bowel obstruction due to an impacted undigested chicken bone.Keywords: small bowel obstruction, chicken bone, bezoar

  2. Animal Models and Bone Histomorphometry: Translational Research for the Human Research Program

    Science.gov (United States)

    Sibonga, Jean D.

    2010-01-01

    This slide presentation reviews the use of animal models to research and inform bone morphology, in particular relating to human research in bone loss as a result of low gravity environments. Reasons for use of animal models as tools for human research programs include: time-efficient, cost-effective, invasive measures, and predictability as some model are predictive for drug effects.

  3. UTIs in small animal patients: part 1: etiology and pathogenesis.

    Science.gov (United States)

    Smee, Nicole; Loyd, Kimberly; Grauer, Greg

    2013-01-01

    Understanding how urinary tract infections (UTIs) can occur and how to classify them can help the practitioner to make a plan for treatment. This review summarizes the etiology, pathogenesis, and host defense mechanisms associated with bacterial UTIs in dogs and cats. UTIs in Small Animal Patients: Part 2: Diagnosis, Treatment, and Complications will appear in the March/April 2013 issue of the Journal of the American Animal Hospital Association.

  4. The biological application of small animal PET imaging

    International Nuclear Information System (INIS)

    Myers, Ralph

    2001-01-01

    The short history of small animal PET is reviewed in the context of its application in the laboratory. Early work has demonstrated a role for the technique in both drug development and in the in vivo monitoring of neuroreceptor function with time. As spatial resolution approaches 1 mm, challenges in quantification remain. However, the ability to carry out animal PET studies that are analogous to human PET will form an important bridge between laboratory and clinical sciences

  5. Euthanasia of Small Animals with Nitrogen; Comparison with Intravenous Pentobarbital

    OpenAIRE

    Quine, John P.; Buckingham, William; Strunin, Leo

    1988-01-01

    Intravenous pentobarbital (with or without addition of saturated potassium chloride) was compared with nitrogen gas exposure for euthanasia of small animals (dogs, cats, and rabbits) in a humane society environment. Initially, electrocardiographic) and electroencephalographic monitoring were used to establish the time of death in presedated animals given either pentobarbital or exposed to nitrogen; later, nitrogen euthanasia alone was studied. Sedation with acepromazine delayed the effects of...

  6. Quantitative separation of bone and muscle radioactivity in small rodents using Dermestid beetles

    International Nuclear Information System (INIS)

    Walburg, H.E.; Eisele, G.R.; Mraz, F.R.

    1979-01-01

    The use of Dermestid beetles, which feed on dead animals, to separate muscle and bone radioactivity in small rodent carcasses was studied. Eviscerated carcasses of mice injected with 1μCi 95 Nb 48hr before killing were placed in jars with adult beetle larvae. Within 3 weeks the skeletons were completely free of muscle. Losses of radioactivity were acceptably small. The actual muscle activity was measured by counting activity in beetles, larvae and excreta, and compared with estimated values. Dermestid digestion has proved to be effective for small carcasses, where size precludes other methods of separation, and is in current use in studies of tissue localization of radionuclides. (author)

  7. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  8. Frequency domain fluorescence diffuse tomography of small animals

    Science.gov (United States)

    Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.

    2007-05-01

    Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.

  9. Treatment planning for a small animal using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chow, James C. L.; Leung, Michael K. K.

    2007-01-01

    The development of a small animal model for radiotherapy research requires a complete setup of customized imaging equipment, irradiators, and planning software that matches the sizes of the subjects. The purpose of this study is to develop and demonstrate the use of a flexible in-house research environment for treatment planning on small animals. The software package, called DOSCTP, provides a user-friendly platform for DICOM computed tomography-based Monte Carlo dose calculation using the EGSnrcMP-based DOSXYZnrc code. Validation of the treatment planning was performed by comparing the dose distributions for simple photon beam geometries calculated through the Pinnacle3 treatment planning system and measurements. A treatment plan for a mouse based on a CT image set by a 360-deg photon arc is demonstrated. It is shown that it is possible to create 3D conformal treatment plans for small animals with consideration of inhomogeneities using small photon beam field sizes in the diameter range of 0.5-5 cm, with conformal dose covering the target volume while sparing the surrounding critical tissue. It is also found that Monte Carlo simulation is suitable to carry out treatment planning dose calculation for small animal anatomy with voxel size about one order of magnitude smaller than that of the human

  10. Importance of Attenuation Correction (AC) for Small Animal PET Imaging

    DEFF Research Database (Denmark)

    El Ali, Henrik H.; Bodholdt, Rasmus Poul; Jørgensen, Jesper Tranekjær

    2012-01-01

    was performed. Methods: Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPETTM Focus 120 and ImTek’s MicroCATTM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity...

  11. Computed tomography of the central nervous system in small animals

    International Nuclear Information System (INIS)

    Tipold, A.; Tipold, E.

    1991-01-01

    With computed tomography in 44 small animals some well defined anatomical structures and pathological processes of the central nervous system are described. Computed tomography is not only necessary for the diagnosis of tumors; malformations, inflammatory, degenerative and vascular diseases and traumas are also visible

  12. Quantification in dynamic and small-animal positron emission tomography

    NARCIS (Netherlands)

    Disselhorst, Johannes Antonius

    2011-01-01

    This thesis covers two aspects of positron emission tomography (PET) quantification. The first section addresses the characterization and optimization of a small-animal PET/CT scanner. The sensitivity and resolution as well as various parameters affecting image quality (reconstruction settings, type

  13. Marketing small animal theriogenology services--one perspective.

    Science.gov (United States)

    Barber, J A

    2007-08-01

    Once a decision is made to add small animal theriogenology services to a practice, marketing strategies must be developed and implemented to attract clients to the new services. Marketing strategies for the niche market of theriogenology include start-up marketing methods, referral programs, internal marketing, and continued marketing. Marketing theriogenology services is a dynamic, ongoing process that never ends.

  14. Monte Carlo simulations in small animal PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Susana [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)], E-mail: susana.silva@fc.ul.pt; Jan, Sebastien [Service Hospitalier Frederic Joliot, CEA/DSV/DRM, Orsay (France); Almeida, Pedro [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)

    2007-10-01

    This work is based on the use of an implemented Positron Emission Tomography (PET) simulation system dedicated for small animal PET imaging. Geant4 Application for Tomographic Emission (GATE), a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET FOCUS system and to implement realistic phantoms, such as the MOBY phantom, and data maps from real examinations. The use of a microPET FOCUS simulation model with GATE has been validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results from realistic studies of the mouse body using {sup -}F and [{sup 18}F]FDG imaging protocols are presented. These simulations include the injection of realistic doses into the animal and realistic time framing. The results have shown that it is possible to simulate small animal PET acquisitions under realistic conditions, and are expected to be useful to improve the quantitative analysis in PET mouse body studies.

  15. Non-Invasive in vivo Imaging in Small Animal Research

    Directory of Open Access Journals (Sweden)

    V. Koo

    2006-01-01

    Full Text Available Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI, Computed Tomography (CT, Positron Emission Tomography (PET, bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

  16. An animal model in sheep for biocompatibility testing of biomaterials in cancellous bones.

    Science.gov (United States)

    Nuss, Katja M R; Auer, Joerg A; Boos, Alois; von Rechenberg, Brigitte

    2006-08-15

    The past years have seen the development of many synthetic bone replacements. To test their biocompatibility and ability for osseointegration, osseoinduction and -conduction requires their placement within bone preferably in an animal experiment of a higher species. A suitable experimental animal model in sheep with drill holes of 8 mm diameter and 13 mm depth within the proximal and distal humerus and femur for testing biocompatibility issues is introduced. This present sheep model allows the placing of up to 8 different test materials within one animal and because of the standardization of the bone defect, routine evaluation by means of histomorphometry is easily conducted. This method was used successfully in 66 White Alpine Sheep. When the drill holes were correctly placed no complications such as spontaneous fractures were encountered. This experimental animal model serves an excellent basis for testing the biocompatibility of novel biomaterials to be used as bone replacement or new bone formation enhancing materials.

  17. An animal model in sheep for biocompatibility testing of biomaterials in cancellous bones

    Science.gov (United States)

    Nuss, Katja MR; Auer, Joerg A; Boos, Alois; Rechenberg, Brigitte von

    2006-01-01

    Background The past years have seen the development of many synthetic bone replacements. To test their biocompatibility and ability for osseointegration, osseoinduction and -conduction requires their placement within bone preferably in an animal experiment of a higher species. Methods A suitable experimental animal model in sheep with drill holes of 8 mm diameter and 13 mm depth within the proximal and distal humerus and femur for testing biocompatibility issues is introduced. Results This present sheep model allows the placing of up to 8 different test materials within one animal and because of the standardization of the bone defect, routine evaluation by means of histomorphometry is easily conducted. This method was used successfully in 66 White Alpine Sheep. When the drill holes were correctly placed no complications such as spontaneous fractures were encountered. Conclusion This experimental animal model serves an excellent basis for testing the biocompatibility of novel biomaterials to be used as bone replacement or new bone formation enhancing materials. PMID:16911787

  18. Bone mineral analysis through dual energy X-ray absorptiometry in laboratory animals

    International Nuclear Information System (INIS)

    Tsujio, Masashi; Mizorogi, Toshihiro; Kitamura, Itsuko

    2009-01-01

    To determine how to eliminate species difference in animal bone experiment, bone mineral content (BMC) was measured using dual energy X-ray absorptiometry (DXA) on the femurs of laboratory mice (Mus musculus) and rats (Rattus norvegicus), and common marmosets (Callithrix jacchus). Measures were taken on femurs in situ, detached from the body, skinned and defleshed, or dried completely. When the BMC of the bone measured in the intact limb attached to the trunk was set at 100%, the actual BMC of the dry bone was 58.7±11.5% in mice and 103.2±3.2% in rats. Similarly, the bone area (Area) and bone mineral density (BMD) of the dried femur was significantly lower in the mouse femurs than intact limb. Thus, soft limb tissue such as skin and muscle modified the BMC, Area, and BMD only in mouse but not in those from rats or marmosets. The bone mineral ratio (BMR; BMC divided by dry bone weight) was nearest to the human bone value in the rat femurs, whereas the mouse femur BMR was the most different. The BMR was proved to be a practical index in evaluating bone characteristics in laboratory animals, but the mouse femur might not be suitable as an animal model for research into the aging of human bone. (author)

  19. INAA of cortical and trabecular bone samples from animals

    International Nuclear Information System (INIS)

    Takata, M.K.; Saiki, M.

    2004-01-01

    Instrumental neutron activation analysis (INAA) was applied to determine Ba, Br, Ca, Cl, Fe, K, Mg, Mn, Na, P, Sr and Zn in bovine and porcine rib bones. Precise results were obtained in analyses of freeze-dried cortical and trabecular bones separately, and also of whole bone ashes. Cortical tissues presented higher concentrations of Ba, Ca, Mg, Mn, Na, P, Sr and Zn than those obtained in trabecular ones. Comparisons were also made between the results obtained for bovine and porcine rib bones. (author)

  20. On the surveillance for animal diseases in small herds

    DEFF Research Database (Denmark)

    Greiner, Matthias; Dekker, Aldo

    2005-01-01

    Small herds may present a problem in surveillance for infectious animal diseases because typical levels of a within-herd design prevalence are not directly applicable. We suggest a definition of small herds as those smaller than 2/(within-herd design prevalence) on the basis that such herds would...... be expected to have less than two (i.e. only one) infected animals. Consequently, the probability of detecting small herds cannot be improved by choosing a larger sample size within the herd. We derive necessary sample sizes of herds and the probability ("confidence") of detecting disease within a stratum...... conservative (lower) estimates of the confidence for a given sample size and should therefore be preferred....

  1. Investigations of 90Sr Activity Concentrations in Animal Bones in Republic of Croatia

    International Nuclear Information System (INIS)

    Maracic, M.; Franic, Z.; Marovic, G.

    2008-01-01

    The paper presents investigations of 90Sr activity concentrations in long bones of some domestic animals (cows, pigs, lambs) collected over the last ten years in the Republic of Croatia. The investigations are a part of an extended and still ongoing monitoring programme of radioactive contamination of human environment of Croatia. Bone is critical organ for the accumulation of many radionuclides, including 90Sr, a highly toxic radionuclide, similar to calcium in its chemical behaviour and metabolic processes. It has been found that the 90Sr activity concentrations in bones differ between respective animal species, the highest activity concentrations being found in lamb bones in year 2005 (472.61 mBqgCa -1 or 2.14 Bqkg -1 ). In cow bones highest value being found was in 1998, being 611.42 mBqgCa -1 or 69.09 Bqkg -1 90Sr. The transient increases and decreases in 90Sr activity concentrations in bones can be partially explained by a variety of environmental physical and biochemical factors that naturally fluctuate. As the levels of stable strontium in bone tissue is strongly correlated to calcium content of bone, 90Sr can be used as efficient radiotracer of stable strontium, which is itself important since it positively affects bone metabolism promoting bone formation and decreasing bone resorption, leading to normalized bone density.(author)

  2. Intrinsic respiratory gating in small-animal CT

    International Nuclear Information System (INIS)

    Bartling, Soenke H.; Dinkel, Julien; Kauczor, Hans-Ulrich; Stiller, Wolfram; Semmler, Wolfhard; Grasruck, Michael; Madisch, Ijad; Gupta, Rajiv; Kiessling, Fabian

    2008-01-01

    Gating in small-animal CT imaging can compensate artefacts caused by physiological motion during scanning. However, all published gating approaches for small animals rely on additional hardware to derive the gating signals. In contrast, in this study a novel method of intrinsic respiratory gating of rodents was developed and tested for mice (n=5), rats (n=5) and rabbits (n=2) in a flat-panel cone-beam CT system. In a consensus read image quality was compared with that of non-gated and retrospective extrinsically gated scans performed using a pneumatic cushion. In comparison to non-gated images, image quality improved significantly using intrinsic and extrinsic gating. Delineation of diaphragm and lung structure improved in all animals. Image quality of intrinsically gated CT was judged to be equivalent to extrinsically gated ones. Additionally 4D datasets were calculated using both gating methods. Values for expiratory, inspiratory and tidal lung volumes determined with the two gating methods were comparable and correlated well with values known from the literature. We could show that intrinsic respiratory gating in rodents makes additional gating hardware and preparatory efforts superfluous. This method improves image quality and allows derivation of functional data. Therefore it bears the potential to find wide applications in small-animal CT imaging. (orig.)

  3. Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

    International Nuclear Information System (INIS)

    Donnelley, Martin; Parsons, David; Morgan, Kaye; Siu, Karen

    2010-01-01

    Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 μm and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the

  4. Hyperpolarized singlet NMR on a small animal imaging system

    DEFF Research Database (Denmark)

    Laustsen, Christoffer; Pileio, Giuseppe; Tayler, Michael C. D.

    2012-01-01

    Nuclear spin hyperpolarization makes a significant advance toward overcoming the sensitivity limitations of in vivo magnetic resonance imaging, particularly in the case of low-gamma nuclei. The sensitivity may be improved further by storing the hyperpolarization in slowly relaxing singlet...... populations of spin- 1/2 pairs. Here, we report hyperpolarized 13C spin order transferred into and retrieved from singlet spin order using a small animal magnetic resonance imaging scanner. For spins in sites with very similar chemical shifts, singlet spin order is sustained in high magnetic field without...... requiring strong radiofrequency irradiation. The demonstration of robust singlet-to-magnetization conversion, and vice versa, on a small animal scanner, is promising for future in vivo and clinical deployments....

  5. Simulation of time curves in small animal PET using GATE

    International Nuclear Information System (INIS)

    Simon, Luc; Strul, Daniel; Santin, Giovanni; Krieguer, Magalie; Morel, Christian

    2004-01-01

    The ClearPET project of the Crystal Clear Collaboration (CCC) is building spin-off technology for high resolution small animal Positron Emission Tomography (PET). Monte Carlo simulation is essential for optimizing the specifications of these systems with regards to their most important characteristics, such as spatial resolution, sensitivity, or count rate performance. GATE, the Geant4 Application for Tomographic Emission simulates the passing of time during real acquisitions, allowing to handle dynamic systems such as decaying source distributions or moving detectors. GATE output is analyzed on an event-by-event basis. The time associated with each single event allows to sort coincidences and to model dead-time. This leads to the study of time curves for a prospective small animal PET scanner design. The count rates of true, and random coincidences are discussed together with the corresponding Noise Equivalent Count (NEC) rates as a function of some PET scanner specifications such as detector dead time, or coincidence time window

  6. [Application of paramunity inducers in small animal practice].

    Science.gov (United States)

    Proksch, A L; Hartmann, K

    2016-01-01

    Paramunity inducers have been used to treat small animals for decades. Paramunity inducers are based on attenuated and inactivated poxviruses (avipox virus and parapox virus). Their applications include both therapeutic and prophylactic use in various diseases. Despite their wide and variable use, only a very small number of placebo-controlled studies has been published. Positive effects in preventing kitten mortality and in treating feline stomatitis have been reported, however, no statistically significant effect of their therapeutic use in canine parvovirus infection, feline leukemia infection virus infection or canine papillomavirus infection could be demonstrated. For these infectious diseases, paramunity inducers do not appear to be effective.

  7. Current concepts in oncologic surgery in small animals.

    Science.gov (United States)

    Matz, Brad M

    2015-05-01

    Surgical oncology is experiencing rapid transition in veterinary medicine. Mast cell tumors and soft tissue sarcomas are two of the most common neoplasms in small animal patients. Clinicians should be familiar with the need for staging and the procedures involved in treating patients with these tumors. Clinicians should be comfortable with available adjuvant therapies and when to use them in certain patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Small Animal Massage Therapy: A Brief Review and Relevant Observations.

    Science.gov (United States)

    Formenton, Maira Rezende; Pereira, Marco Aurélio Amador; Fantoni, Denise Tabacchi

    2017-12-01

    Massage therapy is becoming increasingly popular in human and animal physiotherapy and rehabilitation. Wider application of the technique led to research efforts aimed at providing scientific support to anecdotal beneficial effects, particularly pain relief. Recent studies have shown that massage therapy alters dopamine and serotonin levels, decreases noradrenaline levels, and modulates the immune system. Psychological effects such as reduction of stress and anxiety, with improvement of depressive patients, have been reported in humans. This article set out to review the major aspects of massage therapy based on recent publications on the topic, and to extrapolate concepts and practical aspects described in human physiotherapy to the veterinary patient, particularly the applicability of different techniques in Small Animal Medicine. Indications of massage therapy in small animals include pain relief, orthopedic rehabilitation, Canine Sports Medicine, intensive care, and management of nonspecific edema. Techniques described in this article were originally intended for use in humans and scientific data supporting anecdotal, beneficial effects in domestic animals are still lacking; this fruitful area for research is therefore open to veterinary professionals. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. In vivo small animal imaging: Current status and future prospects

    International Nuclear Information System (INIS)

    Kagadis, George C.; Loudos, George; Katsanos, Konstantinos; Langer, Steve G.; Nikiforidis, George C.

    2010-01-01

    The use of small animal models in basic and preclinical sciences constitutes an integral part of testing new pharmaceutical agents prior to commercial translation to clinical practice. Whole-body small animal imaging is a particularly elegant and cost-effective experimental platform for the timely validation and commercialization of novel agents from the bench to the bedside. Biomedical imaging is now listed along with genomics, proteomics, and metabolomics as an integral part of biological and medical sciences. Miniaturized versions of clinical diagnostic modalities, including but not limited to microcomputed tomography, micromagnetic resonance tomography, microsingle-photon-emission tomography, micropositron-emission tomography, optical imaging, digital angiography, and ultrasound, have all greatly improved our investigative abilities to longitudinally study various experimental models of human disease in mice and rodents. After an exhaustive literature search, the authors present a concise and critical review of in vivo small animal imaging, focusing on currently available modalities as well as emerging imaging technologies on one side and molecularly targeted contrast agents on the other. Aforementioned scientific topics are analyzed in the context of cancer angiogenesis and innovative antiangiogenic strategies under-the-way to the clinic. Proposed hybrid approaches for diagnosis and targeted site-specific therapy are highlighted to offer an intriguing glimpse of the future.

  10. Advances in endoscopic surgery for small animal reproduction.

    Science.gov (United States)

    Katic, N; Dupré, G

    2016-09-01

    Although endoscopic surgery entered its "golden era" in the mid-1980s, it is still advancing at a tremendous pace. Novel surgical techniques and devices are continuously developed and applied, and new indications (and/or contraindications) for the use of endoscopic surgery are routinely reported in the literature and subjected to systematic assessments. Although endoscopic surgery (laparoscopy in particular) has already become established as the gold standard in human medicine, it has yet to be proven as a viable alternative to open surgery in the field of veterinary medicine. The advantages of minimally invasive surgery include better intra-operative visualization, reduced postoperative pain, reduced scar formation and increased postoperative mobility. Therefore, it is reasonable to expect that the application of this will continue to expand. Small animal reproduction, a field within the broad discipline of veterinary medicine, has already recognized and begun to reap the benefits of endoscopic surgery. Herein, we retrospectively review the most recent successful novel applications of endoscopic surgery in the small animal reproduction system to provide small animal reproductive surgeons with important knowledge to help improve their own veterinarian medical practice. © 2016 Blackwell Verlag GmbH.

  11. An animal model in sheep for biocompatibility testing of biomaterials in cancellous bones

    OpenAIRE

    Nuss, Katja MR; Auer, Joerg A; Boos, Alois; Rechenberg, Brigitte von

    2006-01-01

    Abstract Background The past years have seen the development of many synthetic bone replacements. To test their biocompatibility and ability for osseointegration, osseoinduction and -conduction requires their placement within bone preferably in an animal experiment of a higher species. Methods A suitable experimental animal model in sheep with drill holes of 8 mm diameter and 13 mm depth within the proximal and distal humerus and femur for testing biocompatibility issues is introduced. Result...

  12. Neutron activation analysis of medullar and cortical bone tissues from animals

    International Nuclear Information System (INIS)

    Takata, Marcelo Kazuo; Saiki, Mitiko

    2000-01-01

    In this work, neutron activation analysis was applied in the determination of the elements Ba, Br, Ca, Cl, Cr, Fe, K, Mg, Mn, Na, P, Rb, Sb, Sc, Sr and Zn present in animal bone tissues. The obtained results indicated a significant difference between the elemental concentrations present in medullar and cortical tissues. The results obtained for bone tissues from distinct animal species were also different. (author)

  13. Small Animal [18F]FDG PET Imaging for Tumor Model Study

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Kyeong Min; Cheon, Gi Jeong

    2008-01-01

    PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with [ 18 F]FDG has been successfully applied to investigation of metabolism, receptor, ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of [ 18 F]FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal [ 18 F]FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model

  14. Coded Aperture Nuclear Scintigraphy: A Novel Small Animal Imaging Technique

    Directory of Open Access Journals (Sweden)

    Dawid Schellingerhout

    2002-10-01

    Full Text Available We introduce and demonstrate the utility of coded aperture (CA nuclear scintigraphy for imaging small animals. CA imaging uses multiple pinholes in a carefully designed mask pattern, mounted on a conventional gamma camera. System performance was assessed using point sources and phantoms, while several animal experiments were performed to test the usefulness of the imaging system in vivo, with commonly used radiopharmaceuticals. The sensitivity of the CA system for 99mTc was 4.2 × 103 cps/Bq (9400 cpm/μCi, compared to 4.4 × 104 cps/Bq (990 cpm/μCi for a conventional collimator system. The system resolution was 1.7 mm, as compared to 4–6 mm for the conventional imaging system (using a high-sensitivity low-energy collimator. Animal imaging demonstrated artifact-free imaging with superior resolution and image quality compared to conventional collimator images in several mouse and rat models. We conclude that: (a CA imaging is a useful nuclear imaging technique for small animal imaging. The advantage in signal-to-noise can be traded to achieve higher resolution, decreased dose or reduced imaging time. (b CA imaging works best for images where activity is concentrated in small volumes; a low count outline may be better demonstrated using conventional collimator imaging. Thus, CA imaging should be viewed as a technique to complement rather than replace traditional nuclear imaging methods. (c CA hardware and software can be readily adapted to existing gamma cameras, making their implementation a relatively inexpensive retrofit to most systems.

  15. Semiautomated analysis of small-animal PET data.

    Science.gov (United States)

    Kesner, Adam L; Dahlbom, Magnus; Huang, Sung-Cheng; Hsueh, Wei-Ann; Pio, Betty S; Czernin, Johannes; Kreissl, Michael; Wu, Hsiao-Ming; Silverman, Daniel H S

    2006-07-01

    The objective of the work reported here was to develop and test automated methods to calculate biodistribution of PET tracers using small-animal PET images. After developing software that uses visually distinguishable organs and other landmarks on a scan to semiautomatically coregister a digital mouse phantom with a small-animal PET scan, we elastically transformed the phantom to conform to those landmarks in 9 simulated scans and in 18 actual PET scans acquired of 9 mice. Tracer concentrations were automatically calculated in 22 regions of interest (ROIs) reflecting the whole body and 21 individual organs. To assess the accuracy of this approach, we compared the software-measured activities in the ROIs of simulated PET scans with the known activities, and we compared the software-measured activities in the ROIs of real PET scans both with manually established ROI activities in original scan data and with actual radioactivity content in immediately harvested tissues of imaged animals. PET/atlas coregistrations were successfully generated with minimal end-user input, allowing rapid quantification of 22 separate tissue ROIs. The simulated scan analysis found the method to be robust with respect to the overall size and shape of individual animal scans, with average activity values for all organs tested falling within the range of 98% +/- 3% of the organ activity measured in the unstretched phantom scan. Standardized uptake values (SUVs) measured from actual PET scans using this semiautomated method correlated reasonably well with radioactivity content measured in harvested organs (median r = 0.94) and compared favorably with conventional SUV correlations with harvested organ data (median r = 0.825). A semiautomated analytic approach involving coregistration of scan-derived images with atlas-type images can be used in small-animal whole-body radiotracer studies to estimate radioactivity concentrations in organs. This approach is rapid and less labor intensive than are

  16. Fundamental image quality limits for microcomputed tomography in small animals

    International Nuclear Information System (INIS)

    Ford, N.L.; Thornton, M.M.; Holdsworth, D.W.

    2003-01-01

    Small-animal imaging has become increasingly more important as transgenic and knockout mice are produced to model human diseases. One imaging technique that has emerged is microcomputed tomography (micro-CT). For live-animal imaging, the precision in the images will be determined by the x-ray dose given to the animal. As a result, we propose a simple method to predict the noise performance of an x-ray micro-CT system as a function of dose and image resolution. An ideal, quantum-noise limited micro-CT scanner, assumed to have perfect resolution and ideal efficiency, was modeled. Using a simplified model, the coefficient of variation (COV) of the linear attenuation coefficient was calculated for a range of entrance doses and isotropic voxel sizes. COV calculations were performed for the ideal case and with simulated imperfections in efficiency and resolution. Our model was validated in phantom studies and mouse images were acquired with a specimen scanner to illustrate the results. A simplified model of noise propagation in the case of isotropic resolution indicates that the COV in the linear attenuation coefficient is proportional to (dose) -1/2 and to the (isotropic voxel size) -2 in the reconstructed volume. Therefore an improvement in the precision can be achieved only by increasing the isotropic voxel size (thereby decreasing the resolution of the image) or by increasing the x-ray dose. For the ideal scanner, a COV of 1% in the linear attenuation coefficient for an image of a mouse exposed to 0.25 Gy is obtained with a minimum isotropic voxel size of 135 μm. However, the same COV is achieved at a dose of 5.0 Gy with a 65 μm isotropic voxel size. Conversely, for a 68 mm diameter rat, a COV of 1% obtained from an image at 5.0 Gy would require an isotropic voxel size of 100 μm. These results indicate that short-term, potentially lethal, effects of ionizing radiation will limit high-resolution live animal imaging. As improvements in detector technology allow the

  17. Small carpal bone surface area, a characteristic of Turner's syndrome

    International Nuclear Information System (INIS)

    Cleveland, R.H.; Done, S.; Correia, J.A.; Crawford, J.D.; Kushner, D.C.; Herman, T.E.

    1985-01-01

    An abnormality which has received little attention but may be easily recognized on radiographs of the hand of patients with Turner's syndrome is described. Eleven of thirty-one patients (35.5%) with Turner's syndrome were shown on radiographs of the hand to have a visually detectable smallness of the bone surface area of the carpus when compared to the area of the second through fifth metacarpals. Values for the ''C/M'' ratio (the area of the carpals divided by the area of the second through fifth metacarpals) were calculated for films of 31 individuals with gonadal dysgenesis and compared with those from bone age-matched films of seventy-six individuals with normal development of the hand and wrist. A consistent difference with minimal overlap was documented. (orig./WL)

  18. Advances in SPECT Instrumentation (Including Small Animal Scanners). Chapter 4

    International Nuclear Information System (INIS)

    Di Domenico, G.; Zavattini, G.

    2009-01-01

    Fundamental major efforts have been devoted to the development of positron emission tomography (PET) imaging modality over the last few decades. Recently, a novel surge of interest in single photon emission computed tomography (SPECT) technology has occurred, particularly after the introduction of the hybrid SPECT-CT imaging system. This has led to a flourishing of investigations in new types of detectors and collimators, and to more accurate refinement of reconstruction algorithms. Along with SPECT-CT, new, fast gamma cameras have been developed for dedicated cardiac imaging. The existing gap between PET and SPECT in sensitivity and spatial resolution is progressively decreasing, and this trend is particularly apparent in the field of small animal imaging where the most important advances have been reported in SPECT tomographs. An outline of the basic features of SPECT technology, and of recent developments in SPECT instrumentation for both clinical applications and basic biological research on animal models is described. (author)

  19. Micro-computed tomography newly developed for in vivo small animal imaging

    International Nuclear Information System (INIS)

    Arai, Yoshinori; Ninomiya, Tadashi; Kato, Takafumi; Masuda, Yuji

    2005-01-01

    The aim of this paper is to report a newly developed micro-computed tomography system for in vivo use. The system was composed of a micro-focus X-ray tube and an image intensifier (I.I.), both of which rotated around the object stage. A guinea pig and a rat were examined. The anesthetized animal was set on the secure object stage. Images of the head of the guinea pig and the tibia knee joint of the rat were taken. In addition, an image of the rat's tail was taken. The reconstruction and the image viewing were carried out using I-View software. The voxel matrix was 512 x 512 x 384. The voxel sizes ranged from 10 x 10 x 10 μm to 100 x 100 x 100 μm. The exposure time was 17 s, and the reconstruction time was 150 s. The head of the guinea pig and the tibia/knee joint of the rat were observed clearly under 100-μm and 30μm voxels, respectively. The trabecular bone of the tail was also observed clearly under a 10 μm voxel. The newly developed micro-computed tomography system makes it possible to obtain images of anesthetized animals set on a secure object stage. Clear bone images of the small animals could be obtained within a short time. (author)

  20. Computer-aided pulmonary image analysis in small animal models

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J. [Center for Infectious Disease Imaging (CIDI), Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Bagci, Ulas, E-mail: ulasbagci@gmail.com [Center for Research in Computer Vision (CRCV), University of Central Florida (UCF), Orlando, Florida 32816 (United States); Kramer-Marek, Gabriela [The Institute of Cancer Research, London SW7 3RP (United Kingdom); Luna, Brian [Microfluidic Laboratory Automation, University of California-Irvine, Irvine, California 92697-2715 (United States); Kubler, Andre [Department of Medicine, Imperial College London, London SW7 2AZ (United Kingdom); Dey, Bappaditya; Jain, Sanjay [Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Foster, Brent [Department of Biomedical Engineering, University of California-Davis, Davis, California 95817 (United States); Papadakis, Georgios Z. [Radiology and Imaging Sciences, National Institutes of Health (NIH), Bethesda, Maryland 32892 (United States); Camp, Jeremy V. [Department of Microbiology and Immunology, University of Louisville, Louisville, Kentucky 40202 (United States); Jonsson, Colleen B. [National Institute for Mathematical and Biological Synthesis, University of Tennessee, Knoxville, Tennessee 37996 (United States); Bishai, William R. [Howard Hughes Medical Institute, Chevy Chase, Maryland 20815 and Center for Tuberculosis Research, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Udupa, Jayaram K. [Medical Image Processing Group, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2015-07-15

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next. The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.

  1. Hyperspectral small animal fluorescence imaging: spectral selection imaging

    Science.gov (United States)

    Leavesley, Silas; Jiang, Yanan; Patsekin, Valery; Hall, Heidi; Vizard, Douglas; Robinson, J. Paul

    2008-02-01

    Molecular imaging is a rapidly growing area of research, fueled by needs in pharmaceutical drug-development for methods for high-throughput screening, pre-clinical and clinical screening for visualizing tumor growth and drug targeting, and a growing number of applications in the molecular biology fields. Small animal fluorescence imaging employs fluorescent probes to target molecular events in vivo, with a large number of molecular targeting probes readily available. The ease at which new targeting compounds can be developed, the short acquisition times, and the low cost (compared to microCT, MRI, or PET) makes fluorescence imaging attractive. However, small animal fluorescence imaging suffers from high optical scattering, absorption, and autofluorescence. Much of these problems can be overcome through multispectral imaging techniques, which collect images at different fluorescence emission wavelengths, followed by analysis, classification, and spectral deconvolution methods to isolate signals from fluorescence emission. We present an alternative to the current method, using hyperspectral excitation scanning (spectral selection imaging), a technique that allows excitation at any wavelength in the visible and near-infrared wavelength range. In many cases, excitation imaging may be more effective at identifying specific fluorescence signals because of the higher complexity of the fluorophore excitation spectrum. Because the excitation is filtered and not the emission, the resolution limit and image shift imposed by acousto-optic tunable filters have no effect on imager performance. We will discuss design of the imager, optimizing the imager for use in small animal fluorescence imaging, and application of spectral analysis and classification methods for identifying specific fluorescence signals.

  2. Small-Animal Imaging Using Diffuse Fluorescence Tomography.

    Science.gov (United States)

    Davis, Scott C; Tichauer, Kenneth M

    2016-01-01

    Diffuse fluorescence tomography (DFT) has been developed to image the spatial distribution of fluorescence-tagged tracers in living tissue. This capability facilitates the recovery of any number of functional parameters, including enzymatic activity, receptor density, blood flow, and gene expression. However, deploying DFT effectively is complex and often requires years of know-how, especially for newer mutlimodal systems that combine DFT with conventional imaging systems. In this chapter, we step through the process of using MRI-DFT imaging of a receptor-targeted tracer in small animals.

  3. Role of surgery in multimodal cancer therapy for small animals.

    Science.gov (United States)

    Boston, Sarah; Henderson, Ralph A

    2014-09-01

    Surgery is a critical component in the treatment of most solid tumors in small animals. Surgery is increasingly combined with adjuvant therapies such as chemotherapy and radiation so surgeons who are treating cancer must have a good understanding of surgical oncology principles, cancer biology, and the roles and potential interactions of surgery, radiation, and chemotherapy. The sequencing plan for these modalities should be determined before treatment is initiated. The surgical oncologist must have a working knowledge of chemotherapy agents and radiation and the effect of these treatments on the ability of tissues to heal and the outcome for the patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Report on intercomparison A-12 of the determination of radionuclides in animal bone

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1982-12-01

    It is widely recognised that radionuclides contained in food are responsible for the major part of the radiation dose which the human population has received through the development of atomic energy for military purposes. Some of them, such as strontium-89 and -90 or naturally occurring radium-226 and -228, follow calcium into bone and are retained there for long periods. Their expanded radiation may affect the bone and bone-marrow cells. Leukaemia and bone cancer are sometimes considered as a consequence of ingestion of fission products. Many medical and biological laboratories are obliged to determine radionuclides in bone and have to check the accuracy of their results. To meet their needs, the IAEA's Analytical Quality Control Service organized intercomparisons of the determination of fission products and natural radionuclides in calcinated animal bone

  5. Effect of latrogenic trauma on the bone scintigram: an animal study. Concise communication

    International Nuclear Information System (INIS)

    Alazraki, N.; Moitoza, J.; Heaphy, J.; Taylor, A. Jr.

    1984-01-01

    An animal study was performed to assess the effect on the Tc-99m phosphate bone scintigram of injury by needle aspiration or drill hole to metaphyseal and diaphyseal areas in immature and mature bones. Results showed that in 12 immature rabbits such trauma to metaphyseal regions had no effect on the bone image. Similar metaphyseal trauma in two mature dogs showed definite abnormalities on the bone image, but in one mature rabbit, no abnormality could be identified by scintigram. Diaphyseal trauma always gave a definitely abnormal bone image. Extrapolation of these results to humans should be cautious, but it suggests that needling or drilling in metaphyseal regions in neonates or young children probably does not affect later bone images

  6. Development of a Magnetoencephalograph System for Small Animals

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. E.; Kim, I. S.; Kang, C. S.; Kwon, H.; Kim, J. M.; Lee, Y. H.; Kim, K. [Brain and Cognition Measurement Laboratory, Korea Research Institute of Standards and Science(KRISS), Daejeon (Korea, Republic of)

    2011-08-15

    We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/Hz{sup 1/2}/cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

  7. Development of a Magnetoencephalograph System for Small Animals

    International Nuclear Information System (INIS)

    Kim, J. E.; Kim, I. S.; Kang, C. S.; Kwon, H.; Kim, J. M.; Lee, Y. H.; Kim, K.

    2011-01-01

    We developed a four-channel first order gradiometer system to measure magnetoencephalogram for mice. We used double relaxation oscillation SQUID (DROS). The diameter of the pickup coil is 4 mm and the distance between the coils is 5 mm. Coil distance was designed to have good spatial resolution for a small mouse brain. We evaluated the current dipole localization confidence region for a mouse brain, using the spherical conductor model. The white noise of the measurement system was about 30 fT/Hz 1/2 /cm when measured in a magnetically shielded room. We measured magnetic signal from a phantom having the same size of a mouse brain, which was filled with 0.9% saline solution. The results suggest that the developed system has a feasibility to study the functions of brain of small animals.

  8. Veterinarians' perceptions of behaviour support in small-animal practice.

    Science.gov (United States)

    Roshier, A L; McBride, E A

    2013-03-09

    Veterinarians are professionals considered to be at the forefront of animal welfare, including behaviour medicine. However, concerns raised, both within the profession and without, highlight that the support offered is not optimal, due to deficiencies in veterinary training, which focuses on physical aspects and overlooks psychological aspects. This preliminary study explored the experiences and perceptions of six veterinarians (three male, three female, age range: 23-55 years) in two UK small-animal practices. Seventeen annual booster consultations were videoed and conversations thematically analysed for welfare topics discussed. Both veterinarians and clients completed questionnaires to gather demographic information and perspectives. All veterinarians recognised behaviour as a component of their caseload, and acknowledged that clients expected them to provide behaviour support. Veterinarians varied in their experiences of and confidence in providing behaviour support. Five felt unable to meet client expectations; four did not feel their training had prepared them sufficiently. Only one provided dedicated behaviour consultations, the others referred cases. All provided suggestions for behaviour skills needed for new veterinary graduates. The study has afforded an insight into the experiences of a small opportunistic sample of veterinarians. The data indicated important limitations regarding time available in general consultations to discuss behaviour concerns, and practitioner knowledge and skill in detection, anamnesis, assessment and provision of appropriate behaviour information. Suggestions for veterinary training in behaviour are provided.

  9. Preliminary study for small animal preclinical hadrontherapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Russo, G. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Pisciotta, P., E-mail: pietro.pisciotta@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cirrone, G.A.P.; Romano, F. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Acquaviva, R. [University of Catania, Catania (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Cuttone, G. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy)

    2017-02-21

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  10. Preliminary study for small animal preclinical hadrontherapy facility

    Science.gov (United States)

    Russo, G.; Pisciotta, P.; Cirrone, G. A. P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G. I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M. C.; Cuttone, G.

    2017-02-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  11. Preliminary study for small animal preclinical hadrontherapy facility

    International Nuclear Information System (INIS)

    Russo, G.; Pisciotta, P.; Cirrone, G.A.P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M.C.; Cuttone, G.

    2017-01-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  12. Integration of optical imaging with a small animal irradiator

    International Nuclear Information System (INIS)

    Weersink, Robert A.; Ansell, Steve; Wang, An; Wilson, Graham; Shah, Duoaud; Lindsay, Patricia E.; Jaffray, David A.

    2014-01-01

    Purpose: The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (CBCT) imaging. The integration of optical imaging will improve targeting of the radiation treatment and offer longitudinal tracking of tumor response of small animal models treated using the system. Methods: The existing image-guided small animal irradiator consists of a variable kilovolt (peak) x-ray tube mounted opposite an aSi flat panel detector, both mounted on a c-arm gantry. The tube is used for both CBCT imaging and targeted irradiation. The optical component employs a CCD camera perpendicular to the x-ray treatment/imaging axis with a computer controlled filter for spectral decomposition. Multiple optical images can be acquired at any angle as the gantry rotates. The optical to CBCT registration, which uses a standard pinhole camera model, was modeled and tested using phantoms with markers visible in both optical and CBCT images. Optically guided 2D targeting in the anterior/posterior direction was tested on an anthropomorphic mouse phantom with embedded light sources. The accuracy of the mapping of optical signal to the CBCT surface was tested using the same mouse phantom. A surface mesh of the phantom was generated based on the CBCT image and optical intensities projected onto the surface. The measured surface intensity was compared to calculated surface for a point source at the actual source position. The point-source position was also optimized to provide the closest match between measured and calculated intensities, and the distance between the optimized and actual source positions was then calculated. This process was repeated for multiple wavelengths and sources. Results: The optical to CBCT registration error was 0.8 mm. Two

  13. Prompt gamma-ray imaging for small animals

    Science.gov (United States)

    Xu, Libai

    Small animal imaging is recognized as a powerful discovery tool for small animal modeling of human diseases, which is providing an important clue to complete understanding of disease mechanisms and is helping researchers develop and test new treatments. The current small animal imaging techniques include positron emission tomography (PET), single photon emission tomography (SPECT), computed tomography (CT), magnetic resonance imaging (MRI), and ultrasound (US). A new imaging modality called prompt gamma-ray imaging (PGI) has been identified and investigated primarily by Monte Carlo simulation. Currently it is suggested for use on small animals. This new technique could greatly enhance and extend the present capabilities of PET and SPECT imaging from ingested radioisotopes to the imaging of selected non-radioactive elements, such as Gd, Cd, Hg, and B, and has the great potential to be used in Neutron Cancer Therapy to monitor neutron distribution and neutron-capture agent distribution. This approach consists of irradiating small animals in the thermal neutron beam of a nuclear reactor to produce prompt gamma rays from the elements in the sample by the radiative capture (n, gamma) reaction. These prompt gamma rays are emitted in energies that are characteristic of each element and they are also produced in characteristic coincident chains. After measuring these prompt gamma rays by surrounding spectrometry array, the distribution of each element of interest in the sample is reconstructed from the mapping of each detected signature gamma ray by either electronic collimations or mechanical collimations. In addition, the transmitted neutrons from the beam can be simultaneously used for very sensitive anatomical imaging, which provides the registration for the elemental distributions obtained from PGI. The primary approach is to use Monte Carlo simulation methods either with the specific purpose code CEARCPG, developed at NC State University or with the general purpose

  14. Registration-based segmentation with articulated model from multipostural magnetic resonance images for hand bone motion animation.

    Science.gov (United States)

    Chen, Hsin-Chen; Jou, I-Ming; Wang, Chien-Kuo; Su, Fong-Chin; Sun, Yung-Nien

    2010-06-01

    The quantitative measurements of hand bones, including volume, surface, orientation, and position are essential in investigating hand kinematics. Moreover, within the measurement stage, bone segmentation is the most important step due to its certain influences on measuring accuracy. Since hand bones are small and tubular in shape, magnetic resonance (MR) imaging is prone to artifacts such as nonuniform intensity and fuzzy boundaries. Thus, greater detail is required for improving segmentation accuracy. The authors then propose using a novel registration-based method on an articulated hand model to segment hand bones from multipostural MR images. The proposed method consists of the model construction and registration-based segmentation stages. Given a reference postural image, the first stage requires construction of a drivable reference model characterized by hand bone shapes, intensity patterns, and articulated joint mechanism. By applying the reference model to the second stage, the authors initially design a model-based registration pursuant to intensity distribution similarity, MR bone intensity properties, and constraints of model geometry to align the reference model to target bone regions of the given postural image. The authors then refine the resulting surface to improve the superimposition between the registered reference model and target bone boundaries. For each subject, given a reference postural image, the proposed method can automatically segment all hand bones from all other postural images. Compared to the ground truth from two experts, the resulting surface image had an average margin of error within 1 mm (mm) only. In addition, the proposed method showed good agreement on the overlap of bone segmentations by dice similarity coefficient and also demonstrated better segmentation results than conventional methods. The proposed registration-based segmentation method can successfully overcome drawbacks caused by inherent artifacts in MR images and

  15. Small bowel perforation due to fish bone: A case report

    Directory of Open Access Journals (Sweden)

    Huseyin Pulat

    2015-09-01

    Full Text Available Accidental ingestion of foreign bodies are a common condition in clinical practice. However, small bowel perforation which dues to ingestion foreign bodies has been rarely seen. In this article, we report a case of small bowel perforation which dues to ingestion foreign body. A 80-year-old female patient, presenting with complaints of acute abdomen, was admitted to the emergency department. She denied abdominal pain, nausea and vomiting. The patient had tenderness and defense on the right lower quadrant. Contrast enhanced abdominal computed tomography has been used on the patient's diagnosis. This revealed small bowel perforation due to the ingestion of foreign body. The patient was operated emergency. A microperforation due to fish bone was detected on the terminal ileum. The patient underwent debridement and primary repair. The patient was discharged postoperative 7th day without problem. Bowel perforation due to the ingestion of foreign bodies should be considered in the differential diagnosis of acute abdomen. Keywords: Foreign body, Small intestine, Perforation

  16. The therapeutic lamp: treating small-animal phobias.

    Science.gov (United States)

    Wrzesien, Maja; Alcañiz, Mariano; Botella, Cristina; Burkhardt, Jean-Marie; Bretón-López, Juana; Ortega, Mario; Brotons, Daniel Beneito

    2013-01-01

    We all have an irrational fear or two. Some of us get scared by an unexpected visit from a spider in our house; others get nervous when they look down from a high building. Fear is an evolutionary and adaptive function that can promote self-preservation and help us deal with the feared object or situation. However, when this state becomes excessive, it might develop into psychological disorders such as phobias, producing high anxiety and affecting everyday life. The Therapeutic Lamp is an interactive projection-based augmented-reality system for treating small-animal phobias. It aims to increase patient-therapist communication, promote more natural interaction, and improve the patient's engagement in the therapy.

  17. Attenuation correction for the NIH ATLAS small animal PET scanner

    CERN Document Server

    Yao, Rutao; Liow, JeihSan; Seidel, Jurgen

    2003-01-01

    We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to (I for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom, and 3) a mouse injected with left bracket **1**8F right bracket FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.

  18. Utility of Small Animal Models of Developmental Programming.

    Science.gov (United States)

    Reynolds, Clare M; Vickers, Mark H

    2018-01-01

    Any effective strategy to tackle the global obesity and rising noncommunicable disease epidemic requires an in-depth understanding of the mechanisms that underlie these conditions that manifest as a consequence of complex gene-environment interactions. In this context, it is now well established that alterations in the early life environment, including suboptimal nutrition, can result in an increased risk for a range of metabolic, cardiovascular, and behavioral disorders in later life, a process preferentially termed developmental programming. To date, most of the mechanistic knowledge around the processes underpinning development programming has been derived from preclinical research performed mostly, but not exclusively, in laboratory mouse and rat strains. This review will cover the utility of small animal models in developmental programming, the limitations of such models, and potential future directions that are required to fully maximize information derived from preclinical models in order to effectively translate to clinical use.

  19. Imaging of hypoxia in small animals with 18F fluoromisonidasole

    Directory of Open Access Journals (Sweden)

    Kilian Krzysztof

    2016-06-01

    Full Text Available A method of automated synthesis of [18F]fluoromisonidazole ([18F]FMISO for application in preclinical studies on small animals was presented. A remote-controlled synthesizer Synthra RNplus was used for nucleophilic substitution of NITTP (1′-(2′-nitro-1-imidazolyl-2-O-tetrahydropyranyl-3-O-toluenesulfonyl-propanediol with 18F anion. Labeling of 5 mg of precursor was performed in anhydrous acetonitrile at 100°C for 10 min, and the hydrolysis with HCl was performed at 100°C for 5 min. Final purification was done with high-performance liquid chromatography (HPLC and the radiochemical purity of radiotracer was higher than 99%. Proposed [18F]FMISO synthesis was used as a reliable tool in studies on hypoxia in Lewis lung carcinoma (LLC in mouse models.

  20. Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging

    International Nuclear Information System (INIS)

    Chaudhari, Abhijit J; Darvas, Felix; Bading, James R; Moats, Rex A; Conti, Peter S; Smith, Desmond J; Cherry, Simon R; Leahy, Richard M

    2005-01-01

    For bioluminescence imaging studies in small animals, it is important to be able to accurately localize the three-dimensional (3D) distribution of the underlying bioluminescent source. The spectrum of light produced by the source that escapes the subject varies with the depth of the emission source because of the wavelength-dependence of the optical properties of tissue. Consequently, multispectral or hyperspectral data acquisition should help in the 3D localization of deep sources. In this paper, we describe a framework for fully 3D bioluminescence tomographic image acquisition and reconstruction that exploits spectral information. We describe regularized tomographic reconstruction techniques that use semi-infinite slab or FEM-based diffusion approximations of photon transport through turbid media. Singular value decomposition analysis was used for data dimensionality reduction and to illustrate the advantage of using hyperspectral rather than achromatic data. Simulation studies in an atlas-mouse geometry indicated that sub-millimeter resolution may be attainable given accurate knowledge of the optical properties of the animal. A fixed arrangement of mirrors and a single CCD camera were used for simultaneous acquisition of multispectral imaging data over most of the surface of the animal. Phantom studies conducted using this system demonstrated our ability to accurately localize deep point-like sources and show that a resolution of 1.5 to 2.2 mm for depths up to 6 mm can be achieved. We also include an in vivo study of a mouse with a brain tumour expressing firefly luciferase. Co-registration of the reconstructed 3D bioluminescent image with magnetic resonance images indicated good anatomical localization of the tumour

  1. Reduction of acute rejection by bone marrow mesenchymal stem cells during rat small bowel transplantation.

    Directory of Open Access Journals (Sweden)

    Yang Yang

    Full Text Available Bone marrow mesenchymal stem cells (BMMSCs have shown immunosuppressive activity in transplantation. This study was designed to determine whether BMMSCs could improve outcomes of small bowel transplantation in rats.Heterotopic small bowel transplantation was performed from Brown Norway to Lewis rats, followed by infusion of BMMSCs through the superficial dorsal veins of the penis. Controls included rats infused with normal saline (allogeneic control, isogeneically transplanted rats (BN-BN and nontransplanted animals. The animals were sacrificed after 1, 5, 7 or 10 days. Small bowel histology and apoptosis, cytokine concentrations in serum and intestinal grafts, and numbers of T regulatory (Treg cells were assessed at each time point.Acute cellular rejection occurred soon after transplantation and became aggravated over time in the allogeneic control rats, with increase in apoptosis, inflammatory response, and T helper (Th1/Th2 and Th17/Treg-related cytokines. BMMSCs significantly attenuated acute cellular rejection, reduced apoptosis and suppressed the concentrations of interleukin (IL-2, IL-6, IL-17, IL-23, tumor necrosis factor (TNF-α, and interferon (IFN-γ while upregulating IL-10 and transforming growth factor (TGF-β expression and increasing Treg levels.BMMSCs improve the outcomes of allogeneic small bowel transplantation by attenuating the inflammatory response and acute cellular rejection. Treatment with BMMSCs may overcome acute cellular rejection in small bowel transplantation.

  2. Magnetic resonance imaging for precise radiotherapy of small laboratory animals

    Energy Technology Data Exchange (ETDEWEB)

    Frenzel, Thorsten [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Bereich Strahlentherapie; Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Inst. fuer Anatomie und Experimentelle Morphologie; Kaul, Michael Gerhard; Ernst, Thomas Michael; Salamon, Johannes [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Jaeckel, Maria [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radioonkologie; Schumacher, Udo [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Inst. fuer Anatomie und Experimentelle Morphologie; Kruell, Andreas [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Bereich Strahlentherapie

    2017-05-01

    Radiotherapy of small laboratory animals (SLA) is often not as precisely applied as in humans. Here we describe the use of a dedicated SLA magnetic resonance imaging (MRI) scanner for precise tumor volumetry, radiotherapy treatment planning, and diagnostic imaging in order to make the experiments more accurate. Different human cancer cells were injected at the lower trunk of pfp/rag2 and SCID mice to allow for local tumor growth. Data from cross sectional MRI scans were transferred to a clinical treatment planning system (TPS) for humans. Manual palpation of the tumor size was compared with calculated tumor size of the TPS and with tumor weight at necropsy. As a feasibility study MRI based treatment plans were calculated for a clinical 6 MV linear accelerator using a micro multileaf collimator (μMLC). In addition, diagnostic MRI scans were used to investigate animals which did clinical poorly during the study. MRI is superior in precise tumor volume definition whereas manual palpation underestimates their size. Cross sectional MRI allow for treatment planning so that conformal irradiation of mice with a clinical linear accelerator using a μMLC is in principle feasible. Several internal pathologies were detected during the experiment using the dedicated scanner. MRI is a key technology for precise radiotherapy of SLA. The scanning protocols provided are suited for tumor volumetry, treatment planning, and diagnostic imaging.

  3. Laser surgery for selected small animal soft-tissue conditions

    Science.gov (United States)

    Bartels, Kenneth E.

    1991-05-01

    With the acquisition of a Nd:YAG and a CO2 laser in the College of Veterinary Medicine at Oklahoma State University in 1989, over 100 small animal clinical cases have been managed with these modern modalities for surgical excision and tissue vaporization. Most procedures have been for oncologic problems, but inflammatory, infectious, or congenital conditions including vaporization of acral lick 'granulomas,' excision/vaporization of foreign body induced, infected draining tracts, and resection of elongated soft palates have been successfully accomplished. Laser excision or vaporization of both benign and malignant neoplasms have effectively been performed and include feline nasal squamous cell carcinoma, mast cell tumors, and rectal/anal neoplasms. Results to date have been excellent with animals exhibiting little postoperative pain, swelling, and inflammation. Investigations involving application of laser energy for tissue welding of esophageal lacerations and hepatitic interstitial hyperthermia for metastatic colorectal cancer have also shown potential. A review of cases with an emphasis on survival time and postoperative morbidity suggests that carefully planned laser surgical procedures in clinical veterinary practice done with standardized protocols and techniques offer an acceptable means of treating conditions that were previously considered extremely difficult or virtually impossible to perform.

  4. An animal model in sheep for biocompatibility testing of biomaterials in cancellous bones

    Directory of Open Access Journals (Sweden)

    Boos Alois

    2006-08-01

    Full Text Available Abstract Background The past years have seen the development of many synthetic bone replacements. To test their biocompatibility and ability for osseointegration, osseoinduction and -conduction requires their placement within bone preferably in an animal experiment of a higher species. Methods A suitable experimental animal model in sheep with drill holes of 8 mm diameter and 13 mm depth within the proximal and distal humerus and femur for testing biocompatibility issues is introduced. Results This present sheep model allows the placing of up to 8 different test materials within one animal and because of the standardization of the bone defect, routine evaluation by means of histomorphometry is easily conducted. This method was used successfully in 66 White Alpine Sheep. When the drill holes were correctly placed no complications such as spontaneous fractures were encountered. Conclusion This experimental animal model serves an excellent basis for testing the biocompatibility of novel biomaterials to be used as bone replacement or new bone formation enhancing materials.

  5. Investigations of 90 SR activity concentrations in animal bones in Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Maracic, M.; Franic, Z.; Marovic, G. [Institute for Medical Research and Occupational Health, Zagreb (Croatia)

    2006-07-01

    The paper describes investigations of 90 Sr activity concentrations in long bones of some domestic animals (cows, pigs and lambs) collected over the last ten years in the Republic of Croatia. These investigations are a part of an extended and still ongoing monitoring programme of radioactive contamination of human environment in Croatia. Bone is a critical organ for the accumulation of many radionuclides, including 90 Sr, a highly toxic radionuclide, similar to calcium in its chemicalaviour and metabolic processes. It has been found that the 90 Sr activity concentrations in bones differ between respective animal species, the highest activity concentrations being found in lamb bones. As the decrease of activity concentrations can be generally described by the exponential function, by fitting the measured data to the theoretical curve was estimated the ecological half-life of 90 Sr in bones of respective species. In addition was investigated the relation between 90 Sr activity concentrations in bones and fallout. The transient increases and decreases in 90 Sr activity concentrations in bones can be partially explained by a variety of environmental physical factors that naturally fluctuate. (authors)

  6. Investigating the Role of Polyunsaturated Fatty Acids in Bone Development Using Animal Models

    Directory of Open Access Journals (Sweden)

    Beatrice Y.Y. Lau

    2013-11-01

    Full Text Available Incorporating n-3 polyunsaturated fatty acids (PUFA in the diet may promote the development of a healthy skeleton and thereby reduce the risk of developing osteoporosis in later life. Studies using developing animal models suggest lowering dietary n-6 PUFA and increasing n-3 PUFA intakes, especially long chain n-3 PUFA, may be beneficial for achieving higher bone mineral content, density and stronger bones. To date, the evidence regarding the effects of α-linolenic acid (ALA remain equivocal, in contrast to evidence from the longer chain products, eicosapentaenoic acid (EPA and docosahexaenoic acid (DHA. This review reports the results of investigations into n-3 PUFA supplementation on bone fatty acid composition, strength and mineral content in developing animal models as well as the mechanistic relationships of PUFA and bone, and identifies critical areas for future research. Overall, this review supports a probable role for essential (ALA and long chain (EPA and DHA n-3 PUFA for bone health. Understanding the role of PUFA in optimizing bone health may lead to dietary strategies that promote bone development and maintenance of a healthy skeleton.

  7. Investigations of 90 SR activity concentrations in animal bones in Croatia

    International Nuclear Information System (INIS)

    Maracic, M.; Franic, Z.; Marovic, G.

    2006-01-01

    The paper describes investigations of 90 Sr activity concentrations in long bones of some domestic animals (cows, pigs and lambs) collected over the last ten years in the Republic of Croatia. These investigations are a part of an extended and still ongoing monitoring programme of radioactive contamination of human environment in Croatia. Bone is a critical organ for the accumulation of many radionuclides, including 90 Sr, a highly toxic radionuclide, similar to calcium in its chemical behaviour and metabolic processes. It has been found that the 90 Sr activity concentrations in bones differ between respective animal species, the highest activity concentrations being found in lamb bones. As the decrease of activity concentrations can be generally described by the exponential function, by fitting the measured data to the theoretical curve was estimated the ecological half-life of 90 Sr in bones of respective species. In addition was investigated the relation between 90 Sr activity concentrations in bones and fallout. The transient increases and decreases in 90 Sr activity concentrations in bones can be partially explained by a variety of environmental physical factors that naturally fluctuate. (authors)

  8. Neutron activation analysis of NBS oyster tissue (SRM 1566) and IAEA animal bone (H-5)

    International Nuclear Information System (INIS)

    Lepel, E.A.; Laul, J.C.

    1984-03-01

    Instrumental and radiochemical neutron activation analysis (INAA and RNAA) were employed to measure about 37 major, minor, and trace elements in two standard reference materials: oyster tissue (SRM 1566) supplied by the National Bureau of Standards (NBS) and animal bone (H-5) supplied by the International Atomic Energy Agency (IAEA). Wherever the comparison exists, our data show excellent agreement with accepted values for each SRM. These SRM's are useful as reference standards for the analysis of biological materials. Additionally, the chondritic normalized rare earth element pattern of animal bone behaves as a smooth function of the ionic radii, as previously observed for biological materials

  9. [Role of helminth antigens in the abnormal mitosis of bone marrow cells in laboratory animals].

    Science.gov (United States)

    Sivkova, T N; Tatarnikova, N A; Berezhko, V K; Benediktov, I I

    2013-01-01

    The intraabdominal administration of somatic extracts of the cestodes Hydatigera taeniaformis Batsch 1786, Lamarck, 1816 and Diphyllobothrium latum Linnaeus, 1758 and the nematodes Anisakis simplex larva Rudolphi 1809, Toxocara canis Railliet et Henry, 1912 in albino mice proved that these helminths had a karyopathic effect on the bone marrow cells of the animals. The antigenic composition of these extracts was investigated using the agar gel immunodiffusion test. The antigenic composition of the parasites was ascertained to affect their karyopathic properties. The amount of antigens and their foreignness caused a marked karyopathic effect on the bone marrow cells of laboratory animals during intraabdominal administration.

  10. Fluorine determination in human and animal bones by particle-induced gamma-ray emission

    International Nuclear Information System (INIS)

    Sastri, Chaturvedula S.; Hoffmann, Peter; Ortner, Hugo M.; Iyengar, Venkatesh; Blondiaux, Gilbert; Tessier, Yves; Petri, Hermann; Aras, Namik K.; Zaichick, Vladimir

    2002-01-01

    Fluorine was determined in the iliac crest bones of patients and in ribs collected from postmortem investigations by particle-induced gamma-ray emission based on the 19 F(p,pγ) 19 F reaction, using 20/2.5 MeV protons. The results indicate that for 68% of the human samples the F concentration is in the range 500-1999 μg g -1 . For comparison purposes fluorine was also determined in some animal bones; in some animal tissues lateral profiles of fluorine were measured. (abstract)

  11. A new generation of PET scanners for small animal studies

    International Nuclear Information System (INIS)

    Hegyesi, G.; Imrek, J.; Kalinka, G.; Molnar, J.; Novak, D.; Valastyan, I.; Balkay, L.; Emri, M.; Kis, S.; Tron, L.

    2008-01-01

    Complete text of publication follows. Research on small animal PET scanners has been a hot topic in recent years. These devices are used in the preclinical phases of drug tests and during the development of new radiopharmaceuticals. They also provide a cost efficient way to test new materials, new design concepts and new technologies that later can be used to build more efficient human medical imaging devices. The development of a PET scanner requires expertise on different fields, therefore a consortium was formed that brought together Hungarian academic and industrial partners: the Nuclear Research Institute (which has experience in the development of nuclear detectors and data acquisition systems), the PET Center of the University of Debrecen (which has clinical experience in the application of nuclear imaging devices and background in image processing software), Mediso Ltd. (which has been developing, manufacturing, selling and servicing medical imaging devices since 1990) and other academic partners. This consortium has been working together since 2003: the knowledge base acquired during the development of our small animal PET scanners (miniPET-I and miniPET-II) is now being utilized to build a commercial multimodal human PET scanner. The operation of a PET scanner is based on the simultaneous detection ('coincidence') of two gamma photons originating from a positron annihilation. In traditional PET scanners coincidence is detected by a central unit during the measurement. In our system there is no such central module: all detected single gamma events are recorded (list mode data acquisition), and the list of events are processed using a computer cluster (built from PCs). The usage of independent detector modules and commercial components reduce both development and maintenance costs. Also, this mode of data acquisition is more suitable for development purposes, since once the data is collected and stored it can be used many times to test different signal

  12. Key roles of Arf small G proteins and biosynthetic trafficking for animal development.

    Science.gov (United States)

    Rodrigues, Francisco F; Harris, Tony J C

    2017-04-14

    Although biosynthetic trafficking can function constitutively, it also functions specifically for certain developmental processes. These processes require either a large increase to biosynthesis or the biosynthesis and targeted trafficking of specific players. We review the conserved molecular mechanisms that direct biosynthetic trafficking, and discuss how their genetic disruption affects animal development. Specifically, we consider Arf small G proteins, such as Arf1 and Sar1, and their coat effectors, COPI and COPII, and how these proteins promote biosynthetic trafficking for cleavage of the Drosophila embryo, the growth of neuronal dendrites and synapses, extracellular matrix secretion for bone development, lumen development in epithelial tubes, notochord and neural tube development, and ciliogenesis. Specific need for the biosynthetic trafficking system is also evident from conserved CrebA/Creb3-like transcription factors increasing the expression of secretory machinery during several of these developmental processes. Moreover, dysfunctional trafficking leads to a range of developmental syndromes.

  13. Selection of phosphorus solubilizing bacteria with biocontrol potential for growth in phosphorus rich animal bone charcoal

    NARCIS (Netherlands)

    Postma, J.; Nijhuis, E.H.; Sommeus, E.

    2010-01-01

    Bacteria with the ability to solubilize phosphorus (P) and to improve plant health were selected and tested for growth and survival in P-rich animal bone charcoal (ABC). ABC is suggested to be suitable as a carrier for biocontrol agents, offering them a protected niche as well as delivering

  14. Sinography in the investigation of draining tracts in small animals: retrospective review of 25 cases

    International Nuclear Information System (INIS)

    Lamb, C.R.; White, R.N.; McEvoy, F.J.

    1994-01-01

    The signalment, history, clinical signs, radiographic findings, and surgical findings of 25 consecutive animals that had sinography were reviewed to assess the contribution made by sinography to diagnosing and surgically managing draining tracts in small animals. There were 23 dogs and 2 cats; a variety of breeds and both sexes were represented (18 males, 7 females). Before referral the mean duration of clinical signs was 9.8 months (range, 0.5 to 33 months) and a mean of 2.0 surgical procedures (range, 1 to 5) had been performed. Sinuses occurred in a variety of locations, most commonly the neck (10), head (6), and paws (5). The most common cause was foreign body (15). Survey radiographs showed abnormalities in 21 of 26 (78%) instances, including soft-tissue swelling (11), chronic-appearing periosteal reaction on adjacent bones (5), possible foreign body (4), and gas in soft tissues (2). Sinography (or fistulography) enabled definite diagnosis of the cause of the sinus (or fistula) in 15 of 26 (58%) instances and demonstrated 13 of 15 foreign bodies (sensitivity 87%; specificity 100%). Tracts caused by an esophageal perforation and otitis media were also correctly shown by fistulography. In 11 animals, sinography indicated that the position or extent of the lesion was different to that expected on the basis of clinical signs and survey radiographs

  15. New bone-seeking agent. Animal study of Tc-99m-incadronate

    International Nuclear Information System (INIS)

    Shigematsu, Makoto; Shiomi, Susumu; Iwao, Hiroshi; Ochi, Hironobu

    2002-01-01

    Disodium cycloheptylaminomethylenediphosphonate monohydrate (incadronate disodium) is a third-generation bisphosphonate compound which potently inhibits bone resorption, and a highly effective drug in the treatment of metastatic bone disease. We first labeled incadronate disodium with 99m Tc, and examined its biodistribution and bone uptake after intravenous injection in rats to assess its potential for clinical use as a bone-seeking agent for judgment of the therapeutic effect of incadronate on bone metastases. Bone scan with 99m Tc-labeled incadronate ( 99m Tc-incadronate) may yield important information prior to the use of incadronate for treatment of bone metastases. Synthesis of 99m Tc-incadronate was carried out by reduction of 99m Tc-pertechnetate in the presence of SnCl 2 and N 2 gas. Normal rats were injected with 18.5 MBq (0.5 mCi) 99m Tc-incadronate in a volume of 0.1 ml intravenously and then sacrificed at 15 min, 30 min, 1 h or 2 h (six rats at each time point) after injection. Samples of muscle, stomach, small intestine, kidney, liver and bone (femur) were taken and weighed. In addition, a 1-ml sample of blood was drawn from the heart, and urine was taken from the urinary bladder immediately after sacrifice. Samples were measured for radioactivity and expressed as percent uptake of injected dose per gram or per milliliter (% ID/g or ml). Bone-to-blood and bone-to-muscle uptake ratios were determined from the % ID/g or ml values for these organs. The greatest accumulation of 99m Tc-incadronate was found in bone. Radioactivity in bone was as high as 3.22±0.68% ID/g at 2 hours after injection. Scintigraphic images of 99m Tc-incadronate in normal rats revealed highly selective skeletal uptake. 99m Tc-incadronate exhibited high uptake in bone, and relatively low uptake in soft tissue, suggesting that it may be useful as a bone-seeking agent for judgment of the therapeutic effect of incadronate on bone metastases, by determining the degree of its

  16. Tooth-marked small theropod bone: an extremely rare trace

    DEFF Research Database (Denmark)

    Jacobsen, Aase Roland

    2001-01-01

    Tooth-marked dinosaur bones provide insight into feeding behaviours and biting strategies of theropod dinosaurs. The majority of theropod tooth marks reported to date have been found on herbivorous dinosaur bones, although some tyrannosaurid bones with tooth marks have also been reported. In 1988...

  17. A small animal PET prototype based on Silicon Photomultipliers

    International Nuclear Information System (INIS)

    Marcatili, S; Belcari, N.; Bisogni, M.G.; Del Guerra, A.; Collazuol, G.; Pedreschi, E.; Spinella, F.; Sportelli, G.; Marzocca, C.

    2011-01-01

    Next generation PET scanners should full fill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (Si P M) matrices is proposed for the construction of a small animal PET system consisting of two detector heads based on Lyso continuos crystals. The use of large area multi-pixel Silicon Photomultiplier (Si P M) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we developed a DAQ board for the read-out of 2 64-pixel Si P M matrices in time coincidence for Positron Emission Tomography (PET) applications. The proof of principles is based on 64-pixel detectors, but the whole system has been conceived to be easily scalable to a higher number of channels. Here we describe the Group-V INFN DASi P M 2 (Development and Application of Si P M) project and related results.

  18. Filtering and deconvolution for bioluminescence imaging of small animals

    International Nuclear Information System (INIS)

    Akkoul, S.

    2010-01-01

    This thesis is devoted to analysis of bioluminescence images applied to the small animal. This kind of imaging modality is used in cancerology studies. Nevertheless, some problems are related to the diffusion and the absorption of the tissues of the light of internal bioluminescent sources. In addition, system noise and the cosmic rays noise are present. This influences the quality of the images and makes it difficult to analyze. The purpose of this thesis is to overcome these disturbing effects. We first have proposed an image formation model for the bioluminescence images. The processing chain is constituted by a filtering stage followed by a deconvolution stage. We have proposed a new median filter to suppress the random value impulsive noise which corrupts the acquired images; this filter represents the first block of the proposed chain. For the deconvolution stage, we have performed a comparative study of various deconvolution algorithms. It allowed us to choose a blind deconvolution algorithm initialized with the estimated point spread function of the acquisition system. At first, we have validated our global approach by comparing our obtained results with the ground truth. Through various clinical tests, we have shown that the processing chain allows a significant improvement of the spatial resolution and a better distinction of very close tumor sources, what represents considerable contribution for the users of bioluminescence images. (author)

  19. Quantifying the limitations of small animal positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oxley, D.C. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)], E-mail: dco@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cooper, R.J.; Cresswell, J.R.; Grint, A.N.; Nolan, P.J.; Scraggs, D.P. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Warrington, WA4 4AD Cheshire (United Kingdom); Beveridge, T.E. [School of Materials and Engineering, Monash University, Melbourne (Australia)

    2009-06-01

    The application of position sensitive semiconductor detectors in medical imaging is a field of global research interest. The Monte-Carlo simulation toolkit GEANT4 [ (http://geant4.web.cern.ch/geant4/)] was employed to improve the understanding of detailed {gamma}-ray interactions within the small animal Positron Emission Tomography (PET), high-purity germanium (HPGe) imaging system, SmartPET [A.J. Boston, et al., Oral contribution, ANL, Chicago, USA, 2006]. This system has shown promising results in the field of PET [R.J. Cooper, et al., Nucl. Instr. and Meth. A (2009), accepted for publication] and Compton camera imaging [J.E. Gillam, et al., Nucl. Instr. and Meth. A 579 (2007) 76]. Images for a selection of single and multiple point, line and phantom sources were successfully reconstructed using both a filtered-back-projection (FBP) [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007] and an iterative reconstruction algorithm [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007]. Simulated data were exploited as an alternative route to a reconstructed image allowing full quantification of the image distortions introduced in each phase of the data processing. Quantifying the contribution of uncertainty in all system components from detector to reconstruction algorithm allows the areas in need of most attention on the SmartPET project and semiconductor PET to be addressed.

  20. Cell and small animal models for phenotypic drug discovery

    Directory of Open Access Journals (Sweden)

    Szabo M

    2017-06-01

    Full Text Available Mihaly Szabo,1 Sara Svensson Akusjärvi,1 Ankur Saxena,1 Jianping Liu,2 Gayathri Chandrasekar,1 Satish S Kitambi1 1Department of Microbiology Tumor, and Cell Biology, 2Department of Biochemistry and Biophysics, Karolinska Institutet, Solna, Sweden Abstract: The phenotype-based drug discovery (PDD approach is re-emerging as an alternative platform for drug discovery. This review provides an overview of the various model systems and technical advances in imaging and image analyses that strengthen the PDD platform. In PDD screens, compounds of therapeutic value are identified based on the phenotypic perturbations produced irrespective of target(s or mechanism of action. In this article, examples of phenotypic changes that can be detected and quantified with relative ease in a cell-based setup are discussed. In addition, a higher order of PDD screening setup using small animal models is also explored. As PDD screens integrate physiology and multiple signaling mechanisms during the screening process, the identified hits have higher biomedical applicability. Taken together, this review highlights the advantages gained by adopting a PDD approach in drug discovery. Such a PDD platform can complement target-based systems that are currently in practice to accelerate drug discovery. Keywords: phenotype, screening, PDD, discovery, zebrafish, drug

  1. Design considerations and construction of a small animal PET prototype

    International Nuclear Information System (INIS)

    Tzanakos, G.; Nikolaou, M.; Drakoulakos, D.; Karamitros, D.; Kontaxakis, G.; Logaras, E.; Panayiotakis, G.; Pavlopoulos, S.; Skiadas, M.; Spyrou, G.; Thireou, T.; Vamvakas, D.

    2006-01-01

    We are developing a small animal PET scanner consisting of two block detectors, each made of 216 BGO crystals of dimensions 3.75 mmx3.75 mmx20 mm, cylindrically arranged and coupled to a position-sensitive photomultiplier tube (R2486 PSPMT). Our design was based on a very detailed Monte Carlo, that simulates the function of a PET scanner from the system level down to the individual γ-ray detectors. We have made laboratory measurements of the individual detector performance as well as measurements of characteristics of the PSPMTs. The two detector blocks which will form the basic tomographic unit have been assembled. We are developing electronics to individually process (amplify and digitize) anode signals, and use field programmable gate arrays (FPGAs) in the position determination and energy measurement of the γ-rays. At present, as an intermediate step, we are using the electronics supplied from Hamamatsu to study various aspects of the system and produce initial images

  2. Imaging modalities used to confirm diaphragmatic hernia in small animals

    International Nuclear Information System (INIS)

    Williams, J.; Leveille, R.; Myer, C.W.

    1998-01-01

    When a patient is presented for treatment following a traumatic accident such as being hit by a car, thoracic radiographs are usually an integral part of the overall diagnostic evaluation. Diagnosis at diaphragmatic hernia (DH) is often challenging in small animals. The thorax may contain substantial fluid, thereby masking the presence of cranially displaced abdominal soft tissues (e.g., liver or spleen). The most common cause of decreased radiographic visualization of the diaphragm on survey radiographs is pleural fluid; however, the second most common cause is DH. Obviously, if a gas-filledviscus is identified within the thoracic cavity on survey radiographs, the diagnosis of DH is straightforward and relatively routine. If, however, there is substantial pleural effusion and the herniated structure is a soft tissue parenchymal organ (e.g., liver or spleen), the diagnosis is less clearly defined on survey radiographs. This review discusses the various imaging modalities (survey, positional, and contrast-enhanced radiographs and ultrasonography) that can be used in the diagnosis or confirmation of DH

  3. Monte Carlo simulation of small field electron beams for small animal irradiation

    International Nuclear Information System (INIS)

    Lee, Chung-Chi; Chen, Ai-Mei; Tung, Chuan-Jong; Chao, Tsi-Chian

    2011-01-01

    The volume effect of detectors in the dosimetry of small fields for photon beams has been well studied due to interests in radiosurgery and small beamlets used in IMRT treatments; but there is still an unexplored research field for small electron beams used in small animal irradiation. This study proposes to use the BEAM Monte Carlo (MC) simulation to assess characteristics of small electron beams (4, 6, 14, 30 mm in diameter) with the kinetic energies of 6 and 18 MeV. Three factors influencing beam characteristics were studied (1) AE and ECUT settings, (2) photon jaw settings and (3) simulation pixel sizes. Study results reveal that AE/ECUT settings at 0.7 MeV are adequate for linear accelerator treatment head simulation, while 0.521 MeV is more favorable to be used for the phantom study. It is also demonstrated that voxel size setting at 1/4 of the simulation field width in all directions is sufficient to achieve accurate results. As for the photon jaw setting, it has great impact on the absolute output of different field size setting (i.e. output factor) but with minimum effect on the relative lateral distribution.

  4. Radiation-induced relief of pain in an animal model with bone invasion from cancer

    International Nuclear Information System (INIS)

    Seong, J.; Kim, J.; Kim, K.H.; Kim, U.J.; Lee, B.W.

    2003-01-01

    In clinic, local radiation is effective for relief of pain from cancer invasion into the bones. This effect is usually observed before the regression of tumor occurs, which implies radiation-induced pain relief by mechanisms other than tumor irradication. In this study, possible mechanisms were explored in animal model system. To establish an animal model, syngeneic hepatocarcinoma, HCa-I was transplanted on femoral periosteum of C3H/HeJ male mice and bone-invasive tumor growth was identified through the histological analysis. Development of tumor-induced pain was assessed by von Frey filament test, acetone test, and radiant heat test. Animals were also irradiated for their tumors. Any change in pain was analyzed by above tests for the quantitative change and by immunohistochemical stain for the expression of molecules such as c-fos, substance P, and calcitonin gene-related peptide (CGRP) in lumbar spinal cord. Cancer invasion into the bone was started from 7th day after transplantation and became evident at day 14. Objective increase of pain in the ipsilateral thigh was observed at day 14 on von Frey filament test and acetone test, while there was no remarkable regression of the tumors. In this model system, local radiation of tumor resulted in decrease in objective pain on von Frey filament test and acetone test. In the immunohistochemical stain for lumbar spinal cord, the expression of substance P and CGRP but not c-fos increased in tumor-bearing animal compared to the control. The expression of these molecules decreased in animals given local radiation. In summary, an animal model system was established for objective pain from cancer invasion into the bones. Local radiation of tumor induced objective pain relief and this effect seems to be mediated not by tumor regression but through altered production of pain-related molecules

  5. Radiation-induced relief of pain in an animal model with bone invasion from cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seong, J; Kim, J; Kim, K H; Kim, U J; Lee, B W [Yonsei University Medical College, (Korea, Republic of)

    2003-07-01

    In clinic, local radiation is effective for relief of pain from cancer invasion into the bones. This effect is usually observed before the regression of tumor occurs, which implies radiation-induced pain relief by mechanisms other than tumor irradication. In this study, possible mechanisms were explored in animal model system. To establish an animal model, syngeneic hepatocarcinoma, HCa-I was transplanted on femoral periosteum of C3H/HeJ male mice and bone-invasive tumor growth was identified through the histological analysis. Development of tumor-induced pain was assessed by von Frey filament test, acetone test, and radiant heat test. Animals were also irradiated for their tumors. Any change in pain was analyzed by above tests for the quantitative change and by immunohistochemical stain for the expression of molecules such as c-fos, substance P, and calcitonin gene-related peptide (CGRP) in lumbar spinal cord. Cancer invasion into the bone was started from 7th day after transplantation and became evident at day 14. Objective increase of pain in the ipsilateral thigh was observed at day 14 on von Frey filament test and acetone test, while there was no remarkable regression of the tumors. In this model system, local radiation of tumor resulted in decrease in objective pain on von Frey filament test and acetone test. In the immunohistochemical stain for lumbar spinal cord, the expression of substance P and CGRP but not c-fos increased in tumor-bearing animal compared to the control. The expression of these molecules decreased in animals given local radiation. In summary, an animal model system was established for objective pain from cancer invasion into the bones. Local radiation of tumor induced objective pain relief and this effect seems to be mediated not by tumor regression but through altered production of pain-related molecules.

  6. Fluence compensated photoacoustic tomography in small animals (Conference Presentation)

    Science.gov (United States)

    Hussain, Altaf; Pool, Martin; Daoudi, Khalid; de Vries, Liesbeth G.; Steenbergen, Wiendelt

    2017-03-01

    Light fluence inside turbid media can be experimentally mapped by measuring ultrasonically modulated light (Acousto-optics). To demonstrate the feasibility of fluence corrected Photoacoustic (PA) imaging, we have realized a tri-modality (i.e. photoacoustic, acousto-optic and ultrasound) tomographic small animal imaging system. Wherein PA imaging provides high resolution map of absorbed optical energy density, Acousto-optics yields the fluence distribution map in the corresponding PA imaging plane and Ultrasound provides morphological information. Further, normalization of the PA image with the acousto-optically measured fluence map results in an image that directly represents the optical absorption. Human epidermal growth factor receptor 2 (HER2) is commonly found overexpressed in human cancers, among which breast cancers, resulting in a more aggressive tumor phenotype. Identification of HER2-expression is clinically relevant, because cancers overexpressing this marker are amenable to HER2-directed therapies, among which antibodies trastuzumab and pertuzumab. Here, we investigate the feasibility and advantage of acousto-optically assisted fluence compensated PA imaging over PA imaging alone in visualizing and quantifying HER2 expression. For this experiment, nude mice were xenografted with human breast cancer cell lines SKBR3 and BT474 (both HER2 overexpressing), as well as HER2-negative MDA-MB-231. To visualize HER2 expression in these mice, HER2 monoclonal antibody pertuzumab (Perjeta®, Roche), was conjugated to near-infrared dye IRDye 800CW (800CW, LICOR Biosciences) at a ratio of 1∶2 antibody to 800CW. When xenograft tumors measured ≥ 100 mm3, mice received 100 µg 800CW-pertuzumab intravenously. Three days post injection, mice were scanned for fluorescence signal with an IVIS scanner. After fluorescence scans, mice were euthanized and imaged in our PA tomographic imaging system.

  7. Spectroscopic characterization of bone tissue of experimental animals after glucocorticoid treatment and recovery period

    Science.gov (United States)

    Mitić, Žarko J.; Najman, Stevo J.; Cakić, Milorad D.; Ajduković, Zorica R.; Ignjatović, Nenad L.; Nikolić, Ružica S.; Nikolić, Goran M.; Stojanović, Sanja T.; Vukelić, Marija Đ.; Trajanović, Miroslav D.

    2014-09-01

    The influence of glucocorticoids on the composition and mineral/organic content of the mandible in tested animals after recovery and healing phase was investigated in this work. The results of FTIR analysis demonstrated that bone tissue composition was changed after glucocorticoid treatment. The increase of calcium, magnesium, phosphorus content and mineral part of bones was statistically significant in recovery phase and in treatment phase that included calcitonin and thymus extract. Some changes also happened in the organic part of the matrix, as indicated by intensity changes for already present IR bands and the appearance of new IR bands in the region 3500-1300 cm-1.

  8. Influence of culinary processing on the 90Sr extraction from the animal bones

    International Nuclear Information System (INIS)

    Novakova, E.; Petkov, T.; Shopov, N.

    1990-01-01

    The beta-radioactivity of femur of young animals having consummed contaminated food after Chernobyl is measured - fresh, after boiling in the course of 1.5 hrs, and the broth from cookery processing. Before the analysis each sample has been ashed and homogenized. The radioactivity of the samples is registered by a beta-radiometer (with an efficiency for 90 Y - 60%). No statistically significant differences have been established in the 90 Sr content between the processed and unprocessed bones; the radionuclide content in the broth is negligible. In the light of these results the requirements for removing the bones before the culinary processing prove senseless. 1 tab

  9. Subchondral Bone Plate Thickening Precedes Chondrocyte Apoptosis and Cartilage Degradation in Spontaneous Animal Models of Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Zaitunnatakhin Zamli

    2014-01-01

    Full Text Available Osteoarthritis (OA is the most common joint disorder characterised by bone remodelling and cartilage degradation and associated with chondrocyte apoptosis. These processes were investigated at 10, 16, 24, and 30 weeks in Dunkin Hartley (DH and Bristol Strain 2 (BS2 guinea pigs that develop OA spontaneously. Both strains had a more pronounced chondrocyte apoptosis, cartilage degradation, and subchondral bone changes in the medial than the lateral side of the tibia, and between strains, the changes were always greater and faster in DH than BS2. In the medial side, a significant increase of chondrocyte apoptosis and cartilage degradation was observed in DH between 24 and 30 weeks of age preceded by a progressive thickening and stiffening of subchondral bone plate (Sbp. The Sbp thickness consistently increased over the 30-week study period but the bone mineral density (BMD of the Sbp gradually decreased after 16 weeks. The absence of these changes in the medial side of BS2 may indicate that the Sbp of DH was undergoing remodelling. Chondrocyte apoptosis was largely confined to the deep zone of articular cartilage and correlated with thickness of the subchondral bone plate suggesting that cartilage degradation and chondrocyte apoptosis may be a consequence of continuous bone remodelling during the development of OA in these animal models of OA.

  10. Animals

    International Nuclear Information System (INIS)

    Skuterud, L.; Strand, P.; Howard, B.J.

    1997-01-01

    The radionuclides of most concern with respect to contamination of animals after a nuclear accident are radioiodine, radiocaesium and radiostrontium (ICRP 30, 1979). Of the other significant anthropogenic radionuclides likely to be released in most accidents, only small proportions of that ingested will be absorbed in an animals gut, and the main animal products, milk and meat, will not normally be contaminated to a significant extent. Animal products will mostly be contaminated as a result of ingestion of contaminated feed and possibly, but to a much lesser extent, from inhalation (for radioiodine only). Direct external contamination of animals is of little or no consequence in human food production. Radioiodine and radiostrontium are important with respect to contamination of milk; radiocaesium contaminates both milk and meat. The physical and chemical form of a radionuclide can influence its absorption in the animal gut. For example, following the Chernobyl accident radiocaesium incorporated into vegetation by root uptake was more readily absorbed than that associated with the original deposit. The transfer of radiocaesium and radiostrontium to animals will be presented both as transfer coefficients and aggregated transfer coefficients. For most animal meat products, only radiocaesium is important as other radionuclides do not significantly contaminate muscle. Farm animal products are the most important foodstuff determining radiocaesium intake by the average consumer in the Nordic countries. The major potential source of radioiodine and radiostrontium to humans is milk and milk products. Of the different species, the smaller animals have the highest transfer of radiocaesium from fodder to meat and milk. (EG)

  11. Heterogeneous stock rat: a unique animal model for mapping genes influencing bone fragility.

    Science.gov (United States)

    Alam, Imranul; Koller, Daniel L; Sun, Qiwei; Roeder, Ryan K; Cañete, Toni; Blázquez, Gloria; López-Aumatell, Regina; Martínez-Membrives, Esther; Vicens-Costa, Elia; Mont, Carme; Díaz, Sira; Tobeña, Adolf; Fernández-Teruel, Alberto; Whitley, Adam; Strid, Pernilla; Diez, Margarita; Johannesson, Martina; Flint, Jonathan; Econs, Michael J; Turner, Charles H; Foroud, Tatiana

    2011-05-01

    Previously, we demonstrated that skeletal mass, structure and biomechanical properties vary considerably among 11 different inbred rat strains. Subsequently, we performed quantitative trait loci (QTL) analysis in four inbred rat strains (F344, LEW, COP and DA) for different bone phenotypes and identified several candidate genes influencing various bone traits. The standard approach to narrowing QTL intervals down to a few candidate genes typically employs the generation of congenic lines, which is time consuming and often not successful. A potential alternative approach is to use a highly genetically informative animal model resource capable of delivering very high resolution gene mapping such as Heterogeneous stock (HS) rat. HS rat was derived from eight inbred progenitors: ACI/N, BN/SsN, BUF/N, F344/N, M520/N, MR/N, WKY/N and WN/N. The genetic recombination pattern generated across 50 generations in these rats has been shown to deliver ultra-high even gene-level resolution for complex genetic studies. The purpose of this study is to investigate the usefulness of the HS rat model for fine mapping and identification of genes underlying bone fragility phenotypes. We compared bone geometry, density and strength phenotypes at multiple skeletal sites in HS rats with those obtained from five of the eight progenitor inbred strains. In addition, we estimated the heritability for different bone phenotypes in these rats and employed principal component analysis to explore relationships among bone phenotypes in the HS rats. Our study demonstrates that significant variability exists for different skeletal phenotypes in HS rats compared with their inbred progenitors. In addition, we estimated high heritability for several bone phenotypes and biologically interpretable factors explaining significant overall variability, suggesting that the HS rat model could be a unique genetic resource for rapid and efficient discovery of the genetic determinants of bone fragility. Copyright

  12. A cognitive network for oracle-bone characters related to animals

    Science.gov (United States)

    Dress. Andreas; Grünewald, Stefan; Zeng, Zhenbing

    This paper is dedicated to HAO Bailin on the occasion of his eighties birthday, the great scholar and very good friend who never tired to introduce us to the wonderful and complex intricacies of Chinese culture and history. In this paper, we present an analysis of oracle-bone characters for animals from a `cognitive' point of view. After some general remarks on oraclebone characters presented in Section 1 and a short outline of the paper in Section 2, we collect various oracle-bone characters for animals from published resources in Section 3. In the next section, we begin analysing a group of 60 ancient animal characters from www.zdic.net, a highly acclaimed internet dictionary of Chinese characters that is strictly based on historical sources, and introduce five categories of specific features regarding their (graphical) structure that will be used in Section 5 to associate corresponding feature vectors to these characters. In Section 6, these feature vectors will be used to investigate their dissimilarity in terms of a family of parameterised distance measures. And in the last section, we apply the SplitsTree method as encoded in the NeighbourNet algorithms to construct a corresponding family of dissimilarity-based networks with the intention of elucidating how the ancient Chinese might have perceived the `animal world' in the late bronze age and to demonstrate that these pictographs reflect an intuitive understanding of this world and its inherent structure that predates its classification in the oldest surviving Chinese encyclopedia from approximately the 3rd century BC, the ErYa, as well as similar classification systems in the West by one to two millennia. We also present an English dictionary of 70 oracle-bone characters for animals in Appendix 1. In Appendix 2, we list various variants of animal characters that were published in the Jia Gu Wen Bian (cf. , A Complete Collection of Oracle Bone Characters, edited by the Institute of Archaeology of the Chinese

  13. DXA measurements in rett syndrome reveal small bones with low bone mass

    DEFF Research Database (Denmark)

    Roende, Gitte; Ravn, Kirstine; Fuglsang, Kathrine

    2011-01-01

    Low bone mass is reported in growth-retarded patients harboring mutations in the X-linked methyl-CpG-binding protein 2 (MECP2) gene causing Rett syndrome (RTT). We present the first study addressing both bone mineral density (BMD) and bone size in RTT. Our object was to determine whether patients...

  14. Uranium from phosphates to rabbit bones: Predicting dietary contribution to uranium deposition in animal bones

    International Nuclear Information System (INIS)

    Canella Avelar, A.; Motta Ferreira, W.; Menezes, M.

    2014-01-01

    Uranium is a hazardous element, both for radioactivity and metallotoxicity. Health implications of human overexposure to uranium are well documented: from reproduction impairment, liver and kidney diseases to some types of cancer. There are limited data in the modern literature concerning the levels of uranium in animal tissues and foods, as well the dietary daily intake of uranium is not fully known both for man and livestock. On the other hand, practically every phosphate and its products contain uranium in its structure. The average U content in agricultural phosphate may vary from 10 up to 390 ppm. In this particular feature, uranium can reach animal and man food chain by ingestion of feed and food grade phosphate containing U.

  15. A new tissue segmentation method to calculate 3D dose in small animal radiation therapy.

    Science.gov (United States)

    Noblet, C; Delpon, G; Supiot, S; Potiron, V; Paris, F; Chiavassa, S

    2018-02-26

    In pre-clinical animal experiments, radiation delivery is usually delivered with kV photon beams, in contrast to the MV beams used in clinical irradiation, because of the small size of the animals. At this medium energy range, however, the contribution of the photoelectric effect to absorbed dose is significant. Accurate dose calculation therefore requires a more detailed tissue definition because both density (ρ) and elemental composition (Z eff ) affect the dose distribution. Moreover, when applied to cone beam CT (CBCT) acquisitions, the stoichiometric calibration of HU becomes inefficient as it is designed for highly collimated fan beam CT acquisitions. In this study, we propose an automatic tissue segmentation method of CBCT imaging that assigns both density (ρ) and elemental composition (Z eff ) in small animal dose calculation. The method is based on the relationship found between CBCT number and ρ*Z eff product computed from known materials. Monte Carlo calculations were performed to evaluate the impact of ρZ eff variation on the absorbed dose in tissues. These results led to the creation of a tissue database composed of artificial tissues interpolated from tissue values published by the ICRU. The ρZ eff method was validated by measuring transmitted doses through tissue substitute cylinders and a mouse with EBT3 film. Measurements were compared to the results of the Monte Carlo calculations. The study of the impact of ρZ eff variation over the range of materials, from ρZ eff  = 2 g.cm - 3 (lung) to 27 g.cm - 3 (cortical bone) led to the creation of 125 artificial tissues. For tissue substitute cylinders, the use of ρZ eff method led to maximal and average relative differences between the Monte Carlo results and the EBT3 measurements of 3.6% and 1.6%. Equivalent comparison for the mouse gave maximal and average relative differences of 4.4% and 1.2%, inside the 80% isodose area. Gamma analysis led to a 94.9% success rate in the 10% isodose

  16. Neutron activation analysis of NBS oyster tissue (SRM 1566) and IAEA animal bone (H-5)

    International Nuclear Information System (INIS)

    Lepel, E.A.; Laul, J.C.

    1983-10-01

    Data have been presented for 35 elements determined by INAA for NBS oyster tissue (SRM 1566) and for 38 elements determined by INAA and RNAA for IAEA animal bone (H-5). The experimental data showed excellent agreement with published values wherever the comparison exists. Additional trace-element data in the ppb range have been presented for the elements Sc, Sb, Cs, La, Ce, Nd, Sm, Eu, Tb, Dy, Ho, Yb, Lu, Hf, Ta, W and Th in NBS oyster tissue. Also, additional trace-element data for IAEA animal bone (H-5) in the ppb range for the elements Al, Sc, Co, Rb, Cs, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Tm, Yb, lu, Hf, Ta and Th have been presented

  17. Animal Bone Supported SnO2 as Recyclable Photocatalyst for Degradation of Rhodamine B Dye.

    Science.gov (United States)

    Wu, Yun; Wang, Hui; Cao, Mengdie; Zhang, Yichi; Cao, Feifei; Zheng, Xinsheng; Hu, Jinfei; Dong, Jiangshan; Xiao, Zhidong

    2015-09-01

    SnO2 nanoparticles supported on an animal bone which serves as inexpensive and environment-friendly natural products were developed by a facile hydrothermal approach. As a promising photocatalyst, the novel SnO2/porcine bone material exhibited high photocatalytic activity towards the degradation of rhodamine B (RhB) dye under UV-Vis irradiation. About 97.3% of RhB can be effectively decomposed by the catalysis with the SnO2/porcine bone in 90 min, while only 51.5% of RhB can be degraded by pure SnO2 nanoparticles. Moreover, the photocatalytic activity was incremental with the increase of cycle times in previous five cycles. It is mainly because the photocatalyst which has been used for several times possesses a stronger ability of light absorption and utilization compared to the fresh catalyst according to the results of the characterization and relative experiments. It is noteworthy that the animal bone support can improve the activity for the photocatalyst, which would provide further impetus to alternate synthesis strategies for photocatalysts and make the photocatalysis process faster, less expensive, and more environmentally friendly.

  18. Osteoinduction of calcium phosphate biomaterials in small animals

    International Nuclear Information System (INIS)

    Cheng, Lijia; Shi, Yujun; Ye, Feng; Bu, Hong

    2013-01-01

    Although osteoinduction mechanism of calcium phosphate (CP) ceramics is still unclear, several essential properties have been reported, such as chemical composition, pore size and porosity, etc. In this study, calcium phosphate powder (Ca 3 (PO 4 ) 2 , CaP, group 1), biphasic calcium phosphate ceramic powder (BCP, group 2), and intact BCP rods (group 3) were implanted into leg muscles of mice and dorsal muscles of rabbits. One month and three months after implantation, samples were harvested for biological and histological analysis. New bone tissues were observed in 10/10 samples in group 1, 3/10 samples in group 2, and 9/10 samples in group 3 at 3rd month in mice, but not in rabbits. In vitro, human mesenchymal stem cells (hMSCs) were cultured with trace CaP and BCP powder, and osteogenic differentiation was observed at day 7. Our results suggested that chemical composition is the prerequisite in osteoinduction, and pore structure would contribute to more bone formation. - Highlights: ► Intrinsic osteoinduction of calcium phosphate biomaterials was observed implanted in muscles of mice. ► Biomaterials powder also has osteoinduction property. ► Osteogenic genes and protein could be detected by RT-PCR and Western blot in implanted biomaterials. ► Osteogenic phenomenon could be observed by electron microscopy. ► The chemical composition is the prerequisite in osteoinduction, and pore structure would contribute to more bone formation

  19. Osteoinduction of calcium phosphate biomaterials in small animals

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Lijia; Shi, Yujun [Key Laboratory of Transplant Engineering and Immunology, Ministry of Health, West China Hospital, Sichuan University, Chengdu (China); Ye, Feng [Department of Pathology, West China Hospital, Sichuan University, Chengdu, 610041 (China); Bu, Hong, E-mail: hongbu@scu.edu.cn [Key Laboratory of Transplant Engineering and Immunology, Ministry of Health, West China Hospital, Sichuan University, Chengdu (China); Department of Pathology, West China Hospital, Sichuan University, Chengdu, 610041 (China)

    2013-04-01

    Although osteoinduction mechanism of calcium phosphate (CP) ceramics is still unclear, several essential properties have been reported, such as chemical composition, pore size and porosity, etc. In this study, calcium phosphate powder (Ca{sub 3}(PO{sub 4}){sub 2}, CaP, group 1), biphasic calcium phosphate ceramic powder (BCP, group 2), and intact BCP rods (group 3) were implanted into leg muscles of mice and dorsal muscles of rabbits. One month and three months after implantation, samples were harvested for biological and histological analysis. New bone tissues were observed in 10/10 samples in group 1, 3/10 samples in group 2, and 9/10 samples in group 3 at 3rd month in mice, but not in rabbits. In vitro, human mesenchymal stem cells (hMSCs) were cultured with trace CaP and BCP powder, and osteogenic differentiation was observed at day 7. Our results suggested that chemical composition is the prerequisite in osteoinduction, and pore structure would contribute to more bone formation. - Highlights: ► Intrinsic osteoinduction of calcium phosphate biomaterials was observed implanted in muscles of mice. ► Biomaterials powder also has osteoinduction property. ► Osteogenic genes and protein could be detected by RT-PCR and Western blot in implanted biomaterials. ► Osteogenic phenomenon could be observed by electron microscopy. ► The chemical composition is the prerequisite in osteoinduction, and pore structure would contribute to more bone formation.

  20. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  1. Bone marrow stromal cell therapy for ischemic stroke: A meta-analysis of randomized control animal trials.

    Science.gov (United States)

    Wu, Qing; Wang, Yuexiang; Demaerschalk, Bart M; Ghimire, Saruna; Wellik, Kay E; Qu, Wenchun

    2017-04-01

    Background Results of animal studies assessing efficacy of bone marrow stromal cell therapy for ischemic stroke remain inconsistent. Aims The aims are to assess efficacy of bone marrow stromal cell therapy for ischemic stroke in animal studies. Methods Randomized controlled animal trials assessing efficacy of bone marrow stromal cell therapy were eligible. Stroke therapy academic industry round table was used to assess methodologic quality of included studies. Primary outcomes were total infarction volume and modified Neurological Severity Score. Multiple prespecified sensitivity analyses and subgroup analyses were conducted. Random effects models were used for meta-analysis. Results Thirty-three randomized animal trials were included with a total of 796 animals. The median quality score was 6 (interquartile range, 5-7). Bone marrow stromal cell therapy decreased total infarction volume (standardized mean difference, 0.897; 95% confidence interval, 0.553-1.241; P animals treated with bone marrow stromal cell and controls was 2.47 (95% confidence interval, 1.84-3.11; P animal studies. Conclusions Bone marrow stromal cell therapy significantly decreased total infarction volume and increased neural functional recovery in randomized controlled animal models of ischemic stroke.

  2. New approach to intracardiac hemodynamic measurements in small animals

    DEFF Research Database (Denmark)

    Eskesen, Kristian; Olsen, Niels T; Dimaano, Veronica L

    2012-01-01

    Invasive measurements of intracardiac hemodynamics in animal models have allowed important advances in the understanding of cardiac disease. Currently they are performed either through a carotid arteriotomy or via a thoracotomy and apical insertion. Both of these techniques have disadvantages...... and are not conducive to repeated measurements. Therefore, the purpose of this study was to develop a new technique for measuring intracardiac hemodynamics....

  3. Maxillary sinus floor augmentation with Bio-Oss or Bio-Oss mixed with autogenous bone as graft in animals

    DEFF Research Database (Denmark)

    Jensen, T; Schou, S; Stavropoulos, Andreas

    2012-01-01

    The objective of the present systematic review was to test the hypothesis of no differences between the use of Bio-Oss or Bio-Oss mixed with autogenous bone as graft for maxillary sinus floor augmentation (MSFA) applying the lateral window technique, as evaluated in animals. A MEDLINE (Pub...... of the graft improved significantly with increased proportion of Bio-Oss. Bone regeneration, bone-to-implant contact (BIC), biomechanical implant test values, and biodegradation of Bio-Oss after MSFA with Bio-Oss or Bio-Oss mixed with autogenous bone have never been compared within the same study in animals....... Thus, the hypothesis of no differences between the use of Bio-Oss and Bio-Oss mixed with autogenous bone as graft for MSFA could neither be confirmed nor rejected based on existing animal studies....

  4. Animals

    Energy Technology Data Exchange (ETDEWEB)

    Skuterud, L.; Strand, P. [Norwegian Radiation Protection Authority (Norway); Howard, B.J. [Inst. of Terrestrial Ecology (United Kingdom)

    1997-10-01

    The radionuclides of most concern with respect to contamination of animals after a nuclear accident are radioiodine, radiocaesium and radiostrontium (ICRP 30, 1979). Of the other significant anthropogenic radionuclides likely to be released in most accidents, only small proportions of that ingested will be absorbed in an animals gut, and the main animal products, milk and meat, will not normally be contaminated to a significant extent. Animal products will mostly be contaminated as a result of ingestion of contaminated feed and possibly, but to a much lesser extent, from inhalation (for radioiodine only). Direct external contamination of animals is of little or no consequence in human food production. Radioiodine and radiostrontium are important with respect to contamination of milk; radiocaesium contaminates both milk and meat. The physical and chemical form of a radionuclide can influence its absorption in the animal gut. For example, following the Chernobyl accident radiocaesium incorporated into vegetation by root uptake was more readily absorbed than that associated with the original deposit. The transfer of radiocaesium and radiostrontium to animals will be presented both as transfer coefficients and aggregated transfer coefficients. For most animal meat products, only radiocaesium is important as other radionuclides do not significantly contaminate muscle. Farm animal products are the most important foodstuff determining radiocaesium intake by the average consumer in the Nordic countries. The major potential source of radioiodine and radiostrontium to humans is milk and milk products. Of the different species, the smaller animals have the highest transfer of radiocaesium from fodder to meat and milk. (EG). 68 refs.

  5. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    International Nuclear Information System (INIS)

    Han, Su Chul; Park, Seung Woo

    2017-01-01

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom

  6. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Park, Seung Woo [Radilogcial and Medico-Oncological Sciences, University of Sciences and Technology, Daejeon (Korea, Republic of)

    2017-03-15

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

  7. Complications after cryosurgery with new miniature cryoprobes in long hollow bones: An animal trial

    Directory of Open Access Journals (Sweden)

    Fischer Jürgen H

    2005-08-01

    Full Text Available Abstract Background In vitro studies show that new miniature cryoprobes are suitable for cryoablation of bone tissue. The aim of this animal trial on 24 sheep was to examine the perioperative complications, particularly the danger of embolism, of cryoablation when using miniature cryoprobes. Methods Cryoablations with 2 freeze-thaw cycles each were carried out in the epiphysis of the right tibia and the metaphysis of the left femur. Pulmonary artery pressure (PAP and central venous pressure (CVP were measured. Throughout the intra- and perioperative phase, heart rate and oxygen saturation by pulse oxymetry, blood gas and electrolytes were monitored regularly. Postoperative complications were examined up to 24 weeks postoperativ. Results As result, no significant increase of PAP, CVP or heart rate were observed. Blood gases were unremarkable, with pO2 and pCO2 remaining constant throughout the operation. Regarding pH, standard bicarbonate and base excess, only a non-significant shift towards a slight acidosis was seen. There was a mean hemoglobin decrease of 0.5 g/dl. One animal showed postoperative wound infection and wound edge necrosis. No major peri- and postoperative complications associated with cryosurgery of bone were observed, especially regarding clinically relevant pulmonary embolism. Conclusion Surgery with new types of miniature cryoprobes appears to be a safe alternative to or a complement to conventional resection of abnormal bone tissue.

  8. Small molecule alteration of RNA sequence in cells and animals.

    Science.gov (United States)

    Guan, Lirui; Luo, Yiling; Ja, William W; Disney, Matthew D

    2017-10-18

    RNA regulation and maintenance are critical for proper cell function. Small molecules that specifically alter RNA sequence would be exceptionally useful as probes of RNA structure and function or as potential therapeutics. Here, we demonstrate a photochemical approach for altering the trinucleotide expanded repeat causative of myotonic muscular dystrophy type 1 (DM1), r(CUG) exp . The small molecule, 2H-4-Ru, binds to r(CUG) exp and converts guanosine residues to 8-oxo-7,8-dihydroguanosine upon photochemical irradiation. We demonstrate targeted modification upon irradiation in cell culture and in Drosophila larvae provided a diet containing 2H-4-Ru. Our results highlight a general chemical biology approach for altering RNA sequence in vivo by using small molecules and photochemistry. Furthermore, these studies show that addition of 8-oxo-G lesions into RNA 3' untranslated regions does not affect its steady state levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Multispecies animal investigation on biodistribution, pharmacokinetics and toxicity of 177Lu-EDTMP, a potential bone pain palliation agent

    International Nuclear Information System (INIS)

    Mathe, Domokos; Balogh, Lajos; Polyak, Andras; Kiraly, Reka; Marian, Terez; Pawlak, Dariusz; Zaknun, John J.; Pillai, Maroor R.A.; Janoki, Gyozo A.

    2010-01-01

    Introduction: Radionuclide therapy (RNT) is an effective method for bone pain palliation in patients suffering from bone metastasis. Due to the long half-life, easy production and relatively low β- energy, 177 Lu [T 1/2 =6.73 days, E βmax =497 keV, E γ =113 keV (6.4%), 208 keV (11%)]-based radiopharmaceuticals offer logistical advantage for wider use. This paper reports the results of a multispecies biodistribution and toxicity studies of 177 Lu-EDTMP to collect preclinical data for starting human clinical trials. Methods: 177 Lu-EDTMP with radiochemical purity greater than 99% was formulated by using a lyophilized kit of EDTMP (35 mg of EDTMP, 5.72 g of CaO and 14.1 mg of NaOH). Biodistribution studies were conducted in mice and rabbits. Small animal imaging was performed using NanoSPECT/CT (Mediso, Ltd., Hungary) and digital autoradiography. Gamma camera imaging was done in rabbits and dogs. Four levels of activity (9.25 through 37 MBq/kg body weight) of 177 Lu-EDTMP were injected in four groups of three dogs each to study the toxicological effects. Results: 177 Lu-EDTMP accumulated almost exclusively in the skeletal system (peak ca. 41% of the injected activity in bone with terminal elimination half-life of 2130 and 1870 h in mice and rabbits, respectively) with a peak uptake during 1-3 h. Excretion of the radiopharmaceutical was through the urinary system. Imaging studies showed that all species (mouse, rat, rabbit and dog) take up the compound in regions of remodeling bone, while kidney retention is not visible after 1 day postinjection (pi). In dogs, the highest applied activity (37 MBq/kg body weight) led to a moderate decrease in platelet concentration (mean, 160 g/L) at 1 week pi with no toxicity. Conclusion: The protracted effective half-life of 177 Lu-EDTMP in bone supports that modifying the EDTMP molecule by introducing 177 Lu does not alter its biological behaviour as a specific bone-seeking tracer. Species-specific pharmacokinetic behavior

  10. Multispecies animal investigation on biodistribution, pharmacokinetics and toxicity of {sup 177}Lu-EDTMP, a potential bone pain palliation agent

    Energy Technology Data Exchange (ETDEWEB)

    Mathe, Domokos [Department of Applied Radioisotopes and Animal Experimentation, National ' Frederic Joliot-Curie' Institute of Radiobiology and Radiohygiene, H-1221 Budapest (Hungary)], E-mail: mdomokos@hp.osski.hu; Balogh, Lajos; Polyak, Andras; Kiraly, Reka [Department of Applied Radioisotopes and Animal Experimentation, National ' Frederic Joliot-Curie' Institute of Radiobiology and Radiohygiene, H-1221 Budapest (Hungary); Marian, Terez [Institute of Nuclear Medicine, Debrecen University, Debrecen (Hungary); Pawlak, Dariusz [Institute of Atomic Energy, Radioisotope Centre POLATOM, Swierk-Otwock (Poland); Zaknun, John J.; Pillai, Maroor R.A. [International Atomic Energy Agency (IAEA), Vienna (Austria); Janoki, Gyozo A. [Department of Applied Radioisotopes and Animal Experimentation, National ' Frederic Joliot-Curie' Institute of Radiobiology and Radiohygiene, H-1221 Budapest (Hungary)

    2010-02-15

    Introduction: Radionuclide therapy (RNT) is an effective method for bone pain palliation in patients suffering from bone metastasis. Due to the long half-life, easy production and relatively low {beta}- energy, {sup 177}Lu [T{sub 1/2}=6.73 days, E{sub {beta}}{sub max}=497 keV, E{sub {gamma}}=113 keV (6.4%), 208 keV (11%)]-based radiopharmaceuticals offer logistical advantage for wider use. This paper reports the results of a multispecies biodistribution and toxicity studies of {sup 177}Lu-EDTMP to collect preclinical data for starting human clinical trials. Methods: {sup 177}Lu-EDTMP with radiochemical purity greater than 99% was formulated by using a lyophilized kit of EDTMP (35 mg of EDTMP, 5.72 g of CaO and 14.1 mg of NaOH). Biodistribution studies were conducted in mice and rabbits. Small animal imaging was performed using NanoSPECT/CT (Mediso, Ltd., Hungary) and digital autoradiography. Gamma camera imaging was done in rabbits and dogs. Four levels of activity (9.25 through 37 MBq/kg body weight) of {sup 177}Lu-EDTMP were injected in four groups of three dogs each to study the toxicological effects. Results: {sup 177}Lu-EDTMP accumulated almost exclusively in the skeletal system (peak ca. 41% of the injected activity in bone with terminal elimination half-life of 2130 and 1870 h in mice and rabbits, respectively) with a peak uptake during 1-3 h. Excretion of the radiopharmaceutical was through the urinary system. Imaging studies showed that all species (mouse, rat, rabbit and dog) take up the compound in regions of remodeling bone, while kidney retention is not visible after 1 day postinjection (pi). In dogs, the highest applied activity (37 MBq/kg body weight) led to a moderate decrease in platelet concentration (mean, 160 g/L) at 1 week pi with no toxicity. Conclusion: The protracted effective half-life of {sup 177}Lu-EDTMP in bone supports that modifying the EDTMP molecule by introducing {sup 177}Lu does not alter its biological behaviour as a specific bone

  11. Use of perfusion bioreactors and large animal models for long bone tissue engineering.

    Science.gov (United States)

    Gardel, Leandro S; Serra, Luís A; Reis, Rui L; Gomes, Manuela E

    2014-04-01

    Tissue engineering and regenerative medicine (TERM) strategies for generation of new bone tissue includes the combined use of autologous or heterologous mesenchymal stem cells (MSC) and three-dimensional (3D) scaffold materials serving as structural support for the cells, that develop into tissue-like substitutes under appropriate in vitro culture conditions. This approach is very important due to the limitations and risks associated with autologous, as well as allogenic bone grafiting procedures currently used. However, the cultivation of osteoprogenitor cells in 3D scaffolds presents several challenges, such as the efficient transport of nutrient and oxygen and removal of waste products from the cells in the interior of the scaffold. In this context, perfusion bioreactor systems are key components for bone TERM, as many recent studies have shown that such systems can provide dynamic environments with enhanced diffusion of nutrients and therefore, perfusion can be used to generate grafts of clinically relevant sizes and shapes. Nevertheless, to determine whether a developed tissue-like substitute conforms to the requirements of biocompatibility, mechanical stability and safety, it must undergo rigorous testing both in vitro and in vivo. Results from in vitro studies can be difficult to extrapolate to the in vivo situation, and for this reason, the use of animal models is often an essential step in the testing of orthopedic implants before clinical use in humans. This review provides an overview of the concepts, advantages, and challenges associated with different types of perfusion bioreactor systems, particularly focusing on systems that may enable the generation of critical size tissue engineered constructs. Furthermore, this review discusses some of the most frequently used animal models, such as sheep and goats, to study the in vivo functionality of bone implant materials, in critical size defects.

  12. Development and characterization of a novel porous small intestine submucosa-hydroxyapatite scaffold for bone regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Castilla Bolaños, Maria Alejandra, E-mail: ma.castilla964@uniandes.edu.co; Buttigieg, Josef; Briceño Triana, Juan Carlos

    2017-03-01

    The fabricated small intestine submucosa (SIS) – hydroxyapatite (HAp) sponges can act as biomimetic scaffolds to be utilized in tissue engineering and regeneration. Here we developed SIS-HAp sponges and investigated their mechanical, physical and chemical characteristics using scanning electron microscopy, Fourier transformed infrared spectroscopy, uniaxial compression, porosity, and swelling testing techniques. The results demonstrated mechanical properties superior to comparable bone substitutes fabricated with similar methods. SIS-HAp scaffolds possess an interconnected macroporosity, similar to that of trabecular bone, hence presenting a novel biomaterial that may serve as a superior bone substitute and tissue scaffold. - Highlights: • Small intestine submucosa (SIS) – hydroxyapatite (HAp) scaffolds were developed. • SIS-HAp scaffolds possess a trabecular bone-like structure. • FTIR indicated a molecular interaction between the organic groups of SIS and HAp. • SIS-HAp sponges presented a superior Young modulus to comparable bone substitutes.

  13. Development and characterization of a novel porous small intestine submucosa-hydroxyapatite scaffold for bone regeneration

    International Nuclear Information System (INIS)

    Castilla Bolaños, Maria Alejandra; Buttigieg, Josef; Briceño Triana, Juan Carlos

    2017-01-01

    The fabricated small intestine submucosa (SIS) – hydroxyapatite (HAp) sponges can act as biomimetic scaffolds to be utilized in tissue engineering and regeneration. Here we developed SIS-HAp sponges and investigated their mechanical, physical and chemical characteristics using scanning electron microscopy, Fourier transformed infrared spectroscopy, uniaxial compression, porosity, and swelling testing techniques. The results demonstrated mechanical properties superior to comparable bone substitutes fabricated with similar methods. SIS-HAp scaffolds possess an interconnected macroporosity, similar to that of trabecular bone, hence presenting a novel biomaterial that may serve as a superior bone substitute and tissue scaffold. - Highlights: • Small intestine submucosa (SIS) – hydroxyapatite (HAp) scaffolds were developed. • SIS-HAp scaffolds possess a trabecular bone-like structure. • FTIR indicated a molecular interaction between the organic groups of SIS and HAp. • SIS-HAp sponges presented a superior Young modulus to comparable bone substitutes.

  14. Pre-clinical research in small animals using radiotherapy technology. A bidirectional translational approach

    International Nuclear Information System (INIS)

    Tillner, Falk; Buetof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang; Helmholtz-Zentrum Dresden-Rossendorf, Dresden; Technische Univ. Dresden; Helmholtz-Zentrum Dresden-Rossendorf, Dresden

    2014-01-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.

  15. Small animal MRI: clinical MRI as an interface to basic biomedical research

    International Nuclear Information System (INIS)

    Pinkernelle, J.G.; Stelter, L.; Hamm, B.; Teichgraeber, U.

    2008-01-01

    The demand for highly resolved small animal MRI for the purpose of biomedical research has increased constantly. Dedicated small animal MRI scanners working at ultra high field strengths from 4.7 to 7.0 T and even above are MRI at its best. However, using high resolution RF coils in clinical scanners up to 3.0 T, small animal MRI can achieve highly resolved images showing excellent tissue contrast. In fact, in abundant experimental studies, clinical MRI is used for small animal imaging. Mostly clinical RF coils in the single-loop design are applied. In addition, custom-built RF coils and even gradient inserts are used in a clinical scanner. For the reduction of moving artifacts, special MRI-compatible animal ECG und respiration devices are available. In conclusion, clinical devices offer broad availability, are less expense in combination with good imaging performance and provide a translational nature of imaging results. (orig.)

  16. Pre-clinical research in small animals using radiotherapy technology--a bidirectional translational approach.

    Science.gov (United States)

    Tillner, Falk; Thute, Prasad; Bütof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang

    2014-12-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained. Copyright © 2014. Published by Elsevier GmbH.

  17. Pre-clinical research in small animals using radiotherapy technology. A bidirectional translational approach

    Energy Technology Data Exchange (ETDEWEB)

    Tillner, Falk; Buetof, Rebecca [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; Thute, Prasad [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Krause, Mechthild [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; German Cancer Consortium (DKTK), Dresden (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); Enghardt, Wolfgang [Technische Univ. Dresden (Germany). OncoRay - National Center for Radiation Research in Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Univ. Dresden (Germany). Dept. of Radiation Oncology; Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany). Inst. of Radiooncology

    2014-07-01

    For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.

  18. Strontium 90 content in bone samples of deer and domestic animals

    International Nuclear Information System (INIS)

    Kostadinov, K.; Pozhinarova, M.

    1993-01-01

    A comparative radioecological determination of 90 Sr content in leg bone samples of wild deer from Bulgaria (Veliko Tyrnovo), rain deer from Finland (Lapland) and domestic cows and pigs from Bulgaria have been carried out. The study includes four Finish rain deer, three of them 1-5 Y old, shut in 1991, and one - 13.5 Y old, shut in 1974, two Bulgarian deer, 5-6 Y old, shut in 1991, two cows and a pig killed in 1991. The samples have been prepared by a standard procedure. The fumic nitric acid method has been used for chemical separation of 90 Sr, and a low background beta plastic scintillation device - for counting, The results show that the contamination effect is better expressed in the wild animals due to their specific open air manner of life. The 90 Sr activities vary from 41,5 to 136.9 Bq/kg bone in the Bulgarian deer, from 219.5 to 386.1 Bq/kg bone in the three younger Finish deer, and from 1921.0 to 1967.9 Bq/kg bone in the oldest rain deer. The higher 90 Sr values in the samples of the Finish deer can be connected with the specific trophic chain of these animals and the important role in it of lichen. The quantity of 90 Sr in the investigated pig is 10-20 times lower than its content in the deer (2.1 - 4.4 Bq/kg bone). It is explained with the pig's age (10 months old) and the diet based on food grown about 5 years after Chernobyl. There is no significant difference in 90 Sr content of the cows' and deer's samples. This is due to their very similar zoological systems of eating and similar trophic chains (open pasture). The data obtained show a good reproducibility proved by the similar values of the radiochemical yields achieved (60-70%) in each of the analysis made. 1 tab., 1 refs

  19. Bone mineral content measurement in small infants by single-photon absorptiometry: current methodologic issues

    International Nuclear Information System (INIS)

    Steichen, J.J.; Asch, P.A.; Tsang, R.C.

    1988-01-01

    Single-photon absorptiometry (SPA), developed in 1963 and adapted for infants by Steichen et al. in 1976, is an important tool to quantitate bone mineralization in infants. Studies of infants in which SPA was used include studies of fetal bone mineralization and postnatal bone mineralization in very low birth weight infants. The SPA technique has also been used as a research tool to investigate longitudinal bone mineralization and to study the effect of nutrition and disease processes such as rickets or osteopenia of prematurity. At present, it has little direct clinical application for diagnosing bone disease in single patients. The bones most often used to measure bone mineral content (BMC) are the radius, the ulna, and, less often, the humerus. The radius appears to be preferred as a suitable bone to measure BMC in infants. It is easily accessible; anatomic reference points are easily palpated and have a constant relationship to the radial mid-shaft site; soft tissue does not affect either palpation of anatomic reference points or BMC quantitation in vivo. The peripheral location of the radius minimizes body radiation exposure. Trabecular and cortical bone can be measured separately. Extensive background studies exist on radial BMC in small infants. Most important, the radius has a relatively long zone of constant BMC. Finally, SPA for BMC in the radius has a high degree of precision and accuracy. 61 references

  20. Non-invasive 3D-microscopy with 10-μm spatial resolution inside alive small laboratory animals

    International Nuclear Information System (INIS)

    Sasov, A.; Dewaele, D.; De Clerck, N.

    2002-01-01

    Full text: Small laboratory animals (mice and rats) are widely used in development of drugs and treatments. Micro-CT or microtomography allows non-invasive 3D imaging and measurements of the microstructure inside the body of alive animals. To recognise the internal changes of bones and different organs in the very early stage, high-resolution micro-CT scanner for in-vivo 3D-imaging has been developed. The Micro-CT scanner based on the X-ray geometry with source-detector pair rotation around the object instead of object rotation geometry, typical for other micro-CT systems. Object illuminated by an X-ray source with 5 microns spot size and 20-100keV energies. X-ray images collected by a digital x-ray camera. Projection images with 8000x1000x16bit format collected from several hundreds angular projections. On the base of this information cross sectional images can be reconstructed in 8000x8000x32bit full format or 1024x1024x32bit preview. Maximum object size (scanning volume) is 80mm in diameter by 200mm in length with 10-microns isotropic pixel size for reconstruction at any place of this space. All software for system control, reconstruction and 3D analysis runs on Pentium-4 2GHz or Dual Intel Xeon 1.7GHz computer under Microsoft Windows-2000. The instrument is widely used for scanning of physical phantoms as well as different alive small laboratory animals under anesthesia. Achieved spatial resolution is 20microns for low-contrast objects and 10-microns for high-contrast objects (bone, etc.). Typical scanning time is 20-120min, typical irradiation dose - 0.25-0.7Gy per scan. To avoid movement artefacts from breathing, the instrument can synchronise acquisition cycle with pulses from special breathing sensor. Software package includes dual-processor reconstruction software, 3D-rendering and measurement of all general and bone-specific morphological parameters. New in-vivo Micro-CT scanner allows non-destructive 3D-imaging and measurements of the internal

  1. Design and dosimetry of small animal radiation facilities

    Science.gov (United States)

    Rodriguez, Manuel R.

    The aim of this work was to develop an irradiation system for radiobiology studies. We designed a novel image-guided micro-irradiator capable of partial-body zebrafish embryo irradiation. The radiation source is a 50 kV photon beam from a miniature x-ray source (Xoft Inc., CA). The source is inserted in a cylindrical brass collimator, 3 cm in diameter and 3 cm in length. The collimator has a 1 mm-diameter pinhole along the longitudinal axis, which provides a well-focused beam with a sharp penumbra. A photodiode is installed at one exit of the pinhole collimator to monitor the photon dose rate. The source with the collimator is attached under a movable table. A video camera, connected to the computer, is placed above the movable table to record position of the specimens in relation to the pinhole collimator. The captured images are analyzed, and the relative distances between the specimens and the pinhole are calculated. The coordinates are sent to the computer-controlled movable table to accurately position the specimens in the beam. Monte Carlo simulations were performed to characterize dosimetric properties of the system, to determine dosimetric sensitivity, and to help in the design. The image-guidance and high precision of the movable table enable very accurate specimen position. The beam monitoring system provides accurate, fast and easy dose determination. Portability and self-shielding make this system suitable for any radiobiology laboratory. This novel micro-irradiator is appropriate for partial irradiation of zebrafish embryos; however its potential use is much wider like irradiation of cell cultures or other small specimens.

  2. Cone Beam Micro-CT System for Small Animal Imaging and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Shouping Zhu

    2009-01-01

    in this paper. Experimental results show that the system is suitable for small animal imaging and is adequate to provide high-resolution anatomic information for bioluminescence tomography to build a dual modality system.

  3. Glucocorticoid induced osteopenia in cancellous bone of sheep: validation of large animal model for spine fusion and biomaterial research.

    Science.gov (United States)

    Ding, Ming; Cheng, Liming; Bollen, Peter; Schwarz, Peter; Overgaard, Søren

    2010-02-15

    Glucocorticoid with low calcium and phosphorus intake induces osteopenia in cancellous bone of sheep. To validate a large animal model for spine fusion and biomaterial research. A variety of ovariectomized animals has been used to study osteoporosis. Most experimental spine fusions were based on normal animals, and there is a great need for suitable large animal models with adequate bone size that closely resemble osteoporosis in humans. Eighteen female skeletal mature sheep were randomly allocated into 3 groups, 6 each. Group 1 (GC-1) received prednisolone (GC) treatment (0.60 mg/kg/day, 5 times weekly) for 7 months. Group 2 (GC-2) received the same treatment as GC-1 for 7 months followed by 3 months without treatment. Group 3 was left untreated and served as the controls. All sheep received restricted diet with low calcium and phosphorus during experiment. After killing the animals, cancellous bone specimens from the vertebra, femurs, and tibias were micro-CT scanned and tested mechanically. Serum biomarkers were determined. In lumbar vertebra, the GC treatment resulted in significant decrease of cancellous bone volume fraction and trabecular thickness, and bone strength. However, the microarchitecture and bone strength of GC-2 recovered to a similar level of the controls. A similar trend of microarchitectural changes was also observed in the distal femur and proximal tibia of both GC treated sheep. The bone formation marker serum-osteocalcin was largely reduced in GC-1 compared to the controls, but recovered with a rebound increase at month 10 in GC-2. The current investigation demonstrates that the changes in microarchitecture and mechanical properties were comparable with those observed in humans after long-term GC treatment. A prolonged GC treatment is needed for a long-term observation to keep osteopenic bone. This model resembles long-term glucocorticoid treated osteoporotic model, and is useful in preclinical studies.

  4. Validity of bioluminescence measurements for noninvasive in vivo imaging of tumor load in small animals

    NARCIS (Netherlands)

    Klerk, Clara P. W.; Overmeer, Renée M.; Niers, Tatjana M. H.; Versteeg, Henri H.; Richel, Dick J.; Buckle, Tessa; van Noorden, Cornelis J. F.; van Tellingen, Olaf

    2007-01-01

    A relatively new strategy to longitudinally monitor tumor load in intact animals and the effects of therapy is noninvasive bioluminescence imaging (BLI). The validity of BLI for quantitative assessment of tumor load in small animals is critically evaluated in the present review. Cancer cells are

  5. The motivations and methodology for high-throughput PET imaging of small animals in cancer research.

    NARCIS (Netherlands)

    Aide, N.; Visser, E.P.; Lheureux, S.; Heutte, N.; Szanda, I.; Hicks, R.J.

    2012-01-01

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has

  6. Application of MOSFET detectors for dosimetry in small animal radiography using short exposure times.

    Science.gov (United States)

    De Lin, Ming; Toncheva, Greta; Nguyen, Giao; Kim, Sangroh; Anderson-Evans, Colin; Johnson, G Allan; Yoshizumi, Terry T

    2008-08-01

    Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.

  7. Small intestinal submucosa: A potential osteoconductive and osteoinductive biomaterial for bone tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Li, Mei [Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, Ningbo, Zhejiang 315211 (China); Ningbo Medical Science Research Institute, Ningbo, Zhejiang 315020 (China); Zhang, Chi; Cheng, Mengjie; Gu, Qiaoqiao [Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, Ningbo, Zhejiang 315211 (China); Zhao, Jiyuan, E-mail: zhaojiyuan@nbu.edu.cn [Zhejiang Key Laboratory of Pathophysiology, School of Medicine, Ningbo University, Ningbo, Zhejiang 315211 (China)

    2017-06-01

    SIS is an acellular, naturally occurring collagenous extracellular matrix (ECM) material with various bioactive factors, which broadly applied in tissue engineering in clinic. Several studies have applied SIS in bone tissue engineering to enhance bone regeneration in animal models. However, the mechanism was rarely investigated. The aim of the current study was to investigate the osteoconductivity and osteoinductivity of SIS scaffold to bone regeneration systematically and the potential mechanism. Our results showed that SIS scaffold with excellent biocompatibility was beneficial for cell attachment, proliferation, migration and osteogenic differentiation of various cells contributing to bone repair. In mouse calvarial defect model, bone regeneration was significantly enhanced in the defects implanted with SIS scaffolds, along with the up-regulation of BMP-2 and CD31 expression. Accordingly, ID-1, the downstream target gene of BMPs, was increased in BMSCs cultured on SIS scaffolds. The results of this study suggest that SIS scaffold is a potential osteoconductive and osteoinductive biomaterial which plays multiple roles to various cells during process of bone regeneration. - Highlights: • SIS facilitates cell adhesion of BMSCs, osteoblasts and fibroblasts. • SIS promotes cell proliferation of osteoblasts and fibroblasts. • SIS promotes osteogenic differentiation of BMSCs and osteoblasts via BMP-2 pathway. • Synergistic effects of SIS to multiple cells enhance bone regeneration in vivo.

  8. Small intestinal submucosa: A potential osteoconductive and osteoinductive biomaterial for bone tissue engineering

    International Nuclear Information System (INIS)

    Li, Mei; Zhang, Chi; Cheng, Mengjie; Gu, Qiaoqiao; Zhao, Jiyuan

    2017-01-01

    SIS is an acellular, naturally occurring collagenous extracellular matrix (ECM) material with various bioactive factors, which broadly applied in tissue engineering in clinic. Several studies have applied SIS in bone tissue engineering to enhance bone regeneration in animal models. However, the mechanism was rarely investigated. The aim of the current study was to investigate the osteoconductivity and osteoinductivity of SIS scaffold to bone regeneration systematically and the potential mechanism. Our results showed that SIS scaffold with excellent biocompatibility was beneficial for cell attachment, proliferation, migration and osteogenic differentiation of various cells contributing to bone repair. In mouse calvarial defect model, bone regeneration was significantly enhanced in the defects implanted with SIS scaffolds, along with the up-regulation of BMP-2 and CD31 expression. Accordingly, ID-1, the downstream target gene of BMPs, was increased in BMSCs cultured on SIS scaffolds. The results of this study suggest that SIS scaffold is a potential osteoconductive and osteoinductive biomaterial which plays multiple roles to various cells during process of bone regeneration. - Highlights: • SIS facilitates cell adhesion of BMSCs, osteoblasts and fibroblasts. • SIS promotes cell proliferation of osteoblasts and fibroblasts. • SIS promotes osteogenic differentiation of BMSCs and osteoblasts via BMP-2 pathway. • Synergistic effects of SIS to multiple cells enhance bone regeneration in vivo.

  9. Collagen type I from bovine bone. Effect of animal age, bone anatomy and drying methodology on extraction yield, self-assembly, thermal behaviour and electrokinetic potential

    OpenAIRE

    Ferraro, Vincenza; Gaillard-Martinie, Brigitte; Sayd, Thierry; Chambon, Christophe; Anton, Marc; Sante-Lhoutellier, Veronique

    2017-01-01

    Natural collagen is easily available from animal tissues such as bones. Main limitations reported in the use of natural collagen are heterogeneity and loss of integrity during recovery. However, its natural complexity, functionality and bioactivity still remain to be achieved through synthetic and recombinant ways. Variability of physicochemical prope...

  10. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  11. Dry coupling for whole-body small-animal photoacoustic computed tomography

    Science.gov (United States)

    Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.

    2017-04-01

    We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.

  12. An integrated multimodality image-guided robot system for small-animal imaging research

    International Nuclear Information System (INIS)

    Hsu, Wen-Lin; Hsin Wu, Tung; Hsu, Shih-Ming; Chen, Chia-Lin; Lee, Jason J.S.; Huang, Yung-Hui

    2011-01-01

    We design and construct an image-guided robot system for use in small-animal imaging research. This device allows the use of co-registered small-animal PET-MRI images to guide the movements of robotic controllers, which will accurately place a needle probe at any predetermined location inside, for example, a mouse tumor, for biological readouts without sacrificing the animal. This system is composed of three major components: an automated robot device, a CCD monitoring mechanism, and a multimodality registration implementation. Specifically, the CCD monitoring mechanism was used for correction and validation of the robot device. To demonstrate the value of the proposed system, we performed a tumor hypoxia study that involved FMISO small-animal PET imaging and the delivering of a pO 2 probe into the mouse tumor using the image-guided robot system. During our evaluation, the needle positioning error was found to be within 0.153±0.042 mm of desired placement; the phantom simulation errors were within 0.693±0.128 mm. In small-animal studies, the pO 2 probe measurements in the corresponding hypoxia areas showed good correlation with significant, low tissue oxygen tensions (less than 6 mmHg). We have confirmed the feasibility of the system and successfully applied it to small-animal investigations. The system could be easily adapted to extend to other biomedical investigations in the future.

  13. Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals

    International Nuclear Information System (INIS)

    Lee, Byeong Il; Kim, Hyeon Sik; Jeong, Hye Jin; Lee, Hyung Jae; Moon, Seung Min; Kwon, Seung Young; Jeong, Shin Young; Bom, Hee Seung; Min, Jung Joon; Choi, Eun Seo

    2009-01-01

    Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future

  14. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R., E-mail: m_vettorato@hotmail.com [Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2017-11-15

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  15. Implementation of immobilization accessories for positioning of small animals for radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, M.C.; Girotto, C.H.; Fogaça, J.L.; Vulcano, L.C.; Fernandes, M.A.R.

    2017-01-01

    Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes. (author)

  16. Caisson disease of bone: a study of the Göttingen mini-pig as an animal model.

    Science.gov (United States)

    Gregg, P J; Walder, D N; Rannie, I

    1980-02-01

    Investigation of the exact aetiology, early diagnosis and prevention of caisson disease of bone has been hindered by the inability to produce, by the use of realistic compression/decompression exposures, truly comparable lesions in animals. Four Gottingen mini-pigs were subjected to repeated exposures to pressures of 27 p.s.i.g. for 6 h over a period of 9 months and decompressed according to standard tables. Two mini-pigs acted as controls. In one animal radiological changes were recognised in the left lower femoral shaft 19 weeks after the exposures were started and subsequent examination of that bone confirmed the presence, at that site, of a lesion which macroscopically and microscopically resembled, in every way, the appearances of those seen in the shafts of long bones in man. It is concluded therefore that, properly used, the mini-pig may be a suitable animal model for the study of this condition in man.

  17. State of the art in both in vitro and in vivo aspects of small animal imaging

    International Nuclear Information System (INIS)

    Maziere, B.; Lebars, D.

    2002-01-01

    Full text: In vivo imaging for small animals is dramatically expanding due to the coincidence of mainly three technical factors: 1. the explosion in computer power 2. the enhancement in image processing 3. the accessibility and affordability of digital autoradiography systems and small-animal scanners. Among these imaging techniques let us mention the anatomical imaging techniques such as ultrasonography, X-rays and IRM and the functional imaging radioisotopic techniques SPECT and TEP. The main advantage of the first group of imaging techniques is essentially linked to the high resolution of the anatomical images (with the drawback of the necessity of putting the animal at rest using anaesthesia). The main advantages of SPECT and PET are their high sensitivity and the vast number of functions or metabolism they allow to image. The applications for isotopic functional imaging in small animals are increasing rapidly. Factors contributing to this dramatic expansion include the three previous technical factors plus, at least, three methodological factors: 1. the drug discovery process based on receptor / mechanism of action 2. the increasing number of rodent models of human diseases (SCID mice implanted with human tumors, gene knock-out mice, transgene mice) 3. the advances in isotope and validated tracer availability performances Small animal radioisotopic functional imaging for drug development. In vivo quantification of biological processes to measure the mechanism of action of a potential drug and its concentration at the site of action has become mandatory for developing a drug. Rational and efficient means of confirming mechanisms of action are required. For this purpose, PET and/or SPECT functional - biochemical - molecular imaging in small animals are tools of choice for economical reasons (in the domain of drug development, industry is suffering huge opportunity costs by failing to weed out non-performing new active substances until late phases II and III) and

  18. Recommendations on vaccination for Asian small animal practitioners: a report of the WSAVA Vaccination Guidelines Group.

    Science.gov (United States)

    Day, M J; Karkare, U; Schultz, R D; Squires, R; Tsujimoto, H

    2015-02-01

    In 2012 and 2013, the World Small Animal Veterinary Association (WSAVA) Vaccination Guidelines Group (VGG) undertook fact-finding visits to several Asian countries, with a view to developing advice for small companion animal practitioners in Asia related to the administration of vaccines to dogs and cats. The VGG met with numerous first opinion practitioners, small animal association leaders, academic veterinarians, government regulators and industry representatives and gathered further information from a survey of almost 700 veterinarians in India, China, Japan and Thailand. Although there were substantial differences in the nature and magnitude of the challenges faced by veterinarians in each country, and also differences in the resources available to meet those challenges, overall, the VGG identified insufficient undergraduate and postgraduate training in small companion animal microbiology, immunology and vaccinology. In most of the countries, there has been little academic research into small animal infectious diseases. This, coupled with insufficient laboratory diagnostic support, has limited the growth of knowledge concerning the prevalence and circulating strains of key infectious agents in most of the countries visited. Asian practitioners continue to recognise clinical infections that are now considered uncommon or rare in western countries. In particular, canine rabies virus infection poses a continuing threat to animal and human health in this region. Both nationally manufactured and international dog and cat vaccines are variably available in the Asian countries, but the product ranges are small and dominated by multi-component vaccines with a licensed duration of immunity (DOI) of only 1 year, or no description of DOI. Asian practitioners are largely unaware of current global trends in small animal vaccinology or of the WSAVA vaccination guidelines. Consequently, most practitioners continue to deliver annual revaccination with both core and non

  19. Prognostic factors for survival among patients with primary bone sarcomas of small bones

    Directory of Open Access Journals (Sweden)

    Wang Z

    2018-05-01

    Full Text Available Zhan Wang,1,* Shu Li,2,* Yong Li,1 Nong Lin,1 Xin Huang,1 Meng Liu,1 Weibo Pan,1 Xiaobo Yan,1 Lingling Sun,1 Hengyuan, Li,1 Binghao Li,1 Hao Qu,1 Yan Wu,1 Peng Lin,1 Zhaoming Ye1 1Department of Orthopaedics, The Second Affiliated Hospital of Zhejiang University School of Medicine, Centre for Orthopaedic Research, Orthopedics Research Institute of Zhejiang University, Hangzhou, China; 2Key Laboratory of Cancer Prevention and Intervention, Key Laboratory of Molecular Biology in Medical Sciences, National Ministry of Education, Department of Hematology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Cancer Institute, Hangzhou, China *These authors contributed equally to this work Background: Primary bone sarcomas of the hands or feet are rare lesions and poorly documented. Moreover, the prognostic determinants of bone sarcomas of the hands or feet have not been reported. Materials and methods: The Surveillance, Epidemiology, and End Results (SEER program database was used to screen patients with bone sarcomas of the hands or feet from 1973 to 2013, with attention paid to chondrosarcoma, Ewing sarcoma, and osteosarcoma. The prognostic values of overall survival (OS and cancer-specific survival (CSS were assessed using Cox proportional hazards regression model with univariate and multivariate analyses. The Kaplan–Meier method was used to obtain OS and CSS curves. Results: A total of 457 cases were selected from the SEER database. Chondrosarcoma was the most common form of lesion in hands or feet or both, followed by Ewing sarcoma and osteosarcoma. The 5- and 10-year OS rates of the entire group were 75.7% and 66.1%, respectively. The 5- and 10-year CSS rates were 78.7% and 73.7%, respectively. Multivariate analysis revealed that age under 40 years, localized stage, low grade, surgical treatment, and first primary tumor were associated with improved OS, and decade of diagnosis, stage, grade, and surgery were independent

  20. Study of the circumstance influence on the elemental distribution in ancient animal bone using μ-XRF

    International Nuclear Information System (INIS)

    Yan Lingtong; Feng Songlin; Li Li; Xu Wei; Feng Xiangqian; Xie Guoxi

    2010-01-01

    Elemental analysis of archaeological bone plays an important role in the study of the dietary habits of ancient animals. The elemental characteristic of diagenetic skeletons depends on the surrounding circumstance. The study of environmental influence on the elemental concentration of ancient bone is significant. In this paper, the diagenetic influence on archaeological skeletons is analyzed by microbeam X-ray fluorescence (μ-XRF). The results show that the enamel is an excellent barrier to the diagenesis and the element Sr in bone isn't susceptible to contamination from the buried environment. (authors)

  1. Animal versus plant protein and adult bone health: A systematic review and meta-analysis from the National Osteoporosis Foundation.

    Directory of Open Access Journals (Sweden)

    Marissa M Shams-White

    Full Text Available Protein may have both beneficial and detrimental effects on bone health depending on a variety of factors, including protein source.The aim was to conduct a systematic review and meta-analysis evaluating the effects of animal versus plant protein intake on bone mineral density (BMD, bone mineral content (BMC and select bone biomarkers in healthy adults.Searches across five databases were conducted through 10/31/16 for randomized controlled trials (RCTs and prospective cohort studies in healthy adults that examined the effects of animal versus plant protein intake on 1 total body (TB, total hip (TH, lumbar spine (LS or femoral neck (FN BMD or TB BMC for at least one year, or 2 select bone formation and resorption biomarkers for at least six months. Strength of evidence (SOE was assessed and random effect meta-analyses were performed.Seven RCTs examining animal vs. isoflavone-rich soy (Soy+ protein intake in 633 healthy peri-menopausal (n = 1 and post-menopausal (n = 6 women were included. Overall risk of bias was medium. Limited SOE suggests no significant difference between Soy+ vs. animal protein on LS, TH, FN and TB BMD, TB BMC, and bone turnover markers BSAP and NTX. Meta-analysis results showed on average, the differences between Soy+ and animal protein groups were close to zero and not significant for BMD outcomes (LS: n = 4, pooled net % change: 0.24%, 95% CI: -0.80%, 1.28%; TB: n = 3, -0.24%, 95% CI: -0.81%, 0.33%; FN: n = 3, 0.13%, 95% CI: -0.94%, 1.21%. All meta-analyses had no statistical heterogeneity.These results do not support soy protein consumption as more advantageous than animal protein, or vice versa. Future studies are needed examining the effects of different protein sources in different populations on BMD, BMC, and fracture.

  2. The role of laboratory animals in studying bone cancer resulting from skeletally deposited radionuclides

    International Nuclear Information System (INIS)

    Boecker, B.B.; Miller, S.C.; Lloyd, R.D.; Taylor, G.N.; Griffith, W.C.; Guilmette, R.A.; Hahn, F.F.; Muggenburg, B.A.

    1994-01-01

    There is a continuing need to determine and understand the long-term health risks of internally deposited radionuclides in persons exposed medically or occupationally, or from radionuclides in the environment. A full understanding of these health risks, particularly for exposures involving low doses and dose rates, requires in-depth knowledge of both the dosimetry of a given exposure and the resulting long-term biological effects. Human data on 224 Ra and 226,228 Ra and their decay products are our primary sources of knowledge on the health risks of chronic alpha irradiation of the skeleton and serve as essential segments of our radiation protection practices for internally deposited radionuclides. However, we cannot obtain all of the needed information from these studies. This paper examines the role of laboratory animal studies in complementing and extending the knowledge of radiation-induced bone cancer obtained from studies of humans exposed to 224 Ra or 226,228 Ra

  3. SYNTHESIS OF OXIMES WITH THE DOPED POTASSIUM FLUORIDE ANIMAL BONE MEAL AS A CATALYST

    Directory of Open Access Journals (Sweden)

    M. AIT TALEB

    2017-12-01

    Full Text Available The potassium fluoride doped Animal Bone Meal (KF/ABM was prepared and characterized using several techniques to identify the structural properties. After, it has been used as a new and eco-friendly catalyst for the preparation of from aldehydes and ketones oximes under solvent-free conditions. It is clearly shown that this reaction (using this catalyst can lead to the corresponding oximes in good yields (80 % to excellent yields (96 %. In the case of dissymmetric aldehydes and ketones, this catalyst can lead to a mixture of Z- and E- isomers (Z/E = 86/14–90/10. The remarkable advantages of this catalyst are high conversion, short reaction times, cleaner reaction profiles, reusability up to 8 times without significant loss of activity, and reduction in catalyst toxicity.

  4. Small-Diameter Awls Improve Articular Cartilage Repair After Microfracture Treatment in a Translational Animal Model.

    Science.gov (United States)

    Orth, Patrick; Duffner, Julia; Zurakowski, David; Cucchiarini, Magali; Madry, Henning

    2016-01-01

    Microfracture is the most commonly applied arthroscopic marrow stimulation procedure. Articular cartilage repair is improved when the subchondral bone is perforated by small-diameter microfracture awls compared with larger awls. Controlled laboratory study. Standardized rectangular (4 × 8 mm) full-thickness chondral defects (N = 24) were created in the medial femoral condyle of 16 adult sheep and debrided down to the subchondral bone plate. Three treatment groups (n = 8 defects each) were tested: 6 microfracture perforations using small-diameter awls (1.0 mm; group 1), large-diameter awls (1.2 mm; group 2), or without perforations (debridement control; group 3). Osteochondral repair was assessed at 6 months in vivo using established macroscopic, histological, immunohistochemical, biochemical, and micro-computed tomography analyses. Compared with control defects, histological cartilage repair was always improved after both microfracture techniques (P Subchondral bone cysts and intralesional osteophytes were frequently observed after either microfracture treatment. Macroscopic grading, DNA, proteoglycan, and type I and type II collagen contents as well as degenerative changes within the adjacent cartilage remained unaffected by the awl diameter. Small-diameter microfracture awls improve articular cartilage repair in the translational sheep model more effectively than do larger awls. These data support the use of small microfracture instruments for the surgical treatment of cartilage defects and warrant prolonged clinical investigations. © 2015 The Author(s).

  5. Bone formation in mono cortical mandibular critical size defects after augmentation with two synthetic nanostructured and one xenogenous hydroxyapatite bone substitute - in vivo animal study.

    Science.gov (United States)

    Dau, Michael; Kämmerer, Peer W; Henkel, Kai-Olaf; Gerber, Thomas; Frerich, Bernhard; Gundlach, Karsten K H

    2016-05-01

    Healing characteristics as well as level of tissue integration and degradation of two different nanostructured hydroxyapatite bone substitute materials (BSM) in comparison with a deproteinized hydroxyapatite bovine BSM were evaluated in an in vivo animal experiment. In the posterior mandible of 18 minipigs, bilateral mono cortical critical size bone defects were created. Randomized augmentation procedures with NanoBone(®) (NHA1), Ostim(®) (NHA2) or Bio-Oss(®) (DBBM) were conducted (each material n = 12). Samples were analyzed after five (each material n = 6) and 8 months (each material n = 6). Defect healing, formation of soft tissue and bone as well as the amount of remaining respective BSM were quantified both macro- and microscopically. For NHA2, the residual bone defect after 5 weeks was significantly less compared to NHA1 or DBBM. There was no difference in residual BSM between NHA1 and DBBM, but the amount in NHA2 was significantly lower. NHA2 also showed the least amount of soft tissue and the highest amount of new bone after 5 weeks. Eight months after implantation, no significant differences in the amount of residual bone defects, in soft tissue or in bone formation were detected between the groups. Again, NHA2 showed significant less residual material than NHA1 and DBBM. We observed non-significant differences in the biological hard tissue response of NHA1 and DBBM. The water-soluble NHA2 initially induced an increased amount of new bone but was highly compressed which may have a negative effect in less stable augmentations of the jaw. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Bone regeneration in experimental animals using calcium phosphate cement combined with platelet growth factors and human growth hormone.

    Science.gov (United States)

    Emilov-Velev, K; Clemente-de-Arriba, C; Alobera-García, M Á; Moreno-Sansalvador, E M; Campo-Loarte, J

    2015-01-01

    Many substances (growth factors and hormones) have osteoinduction properties and when added to some osteoconduction biomaterial they accelerate bone neoformation properties. The materials included 15 New Zealand rabbits, calcium phosphate cement (Calcibon(®)), human growth hormone (GH), and plasma rich in platelets (PRP). Each animal was operated on in both proximal tibias and a critical size bone defect of 6mm of diameter was made. The animals were separated into the following study groups: Control (regeneration only by Calcibon®), PRP (regeneration by Calcibon® and PRP), GH (regeneration by Calcibon® and GH). All the animals were sacrificed at 28 days. An evaluation was made of the appearance of the proximal extreme of rabbit tibiae in all the animals, and to check the filling of the critical size defect. A histological assessment was made of the tissue response, the presence of new bone formation, and the appearance of the biomaterial. Morphometry was performed using the MIP 45 image analyser. ANOVA statistical analysis was performed using the Statgraphics software application. The macroscopic appearance of the critical defect was better in the PRP and the GH group than in the control group. Histologically greater new bone formation was found in the PRP and GH groups. No statistically significant differences were detected in the morphometric study between bone formation observed in the PRP group and the control group. Significant differences in increased bone formation were found in the GH group (p=0.03) compared to the other two groups. GH facilitates bone regeneration in critical defects filled with calcium phosphate cement in the time period studied in New Zealand rabbits. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  7. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75) on Bone Ingrowth in an Experimental Animal Model.

    Science.gov (United States)

    Zuchuat, Jésica; Berli, Marcelo; Maldonado, Ysaí; Decco, Oscar

    2017-12-26

    Cr-Co-Mo (ASTM F75) alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  8. Influence of Chromium-Cobalt-Molybdenum Alloy (ASTM F75 on Bone Ingrowth in an Experimental Animal Model

    Directory of Open Access Journals (Sweden)

    Jésica Zuchuat

    2017-12-01

    Full Text Available Cr-Co-Mo (ASTM F75 alloy has been used in the medical environment, but its use as a rigid barrier membrane for supporting bone augmentation therapies has not been extensively investigated. In the present study, Cr-Co-Mo membranes of different heights were placed in New Zealand white, male rabbit tibiae to assess the quality and volume of new bone formation, without the use of additional factors. Animals were euthanized at 20, 30, 40, and 60 days. Bone formation was observed in all of the cases, although the tibiae implanted with the standard membranes reached an augmentation of bone volume that agreed with the density values over the timecourse. In all cases, plasmatic exudate was found under the membrane and in contact with the new bone. Histological analysis indicated the presence of a large number of chondroblasts adjacent to the inner membrane surface in the first stages, and osteoblasts and osteocytes were observed under them. The bone formation was appositional. The Cr-Co-Mo alloy provides a scaffold with an adequate microenvironment for vertical bone volume augmentation, and the physical dimensions and disposition of the membrane itself influence the new bone formation.

  9. Glucocorticoid induced osteopenia in cancellous bone of sheep: validation of large animal model for spine fusion and biomaterial research

    DEFF Research Database (Denmark)

    Ding, Ming; Cheng, Liming; Bollen, Peter

    2010-01-01

    STUDY DESIGN: Glucocorticoid with low calcium and phosphorus intake induces osteopenia in cancellous bone of sheep. OBJECTIVE: To validate a large animal model for spine fusion and biomaterial research. SUMMARY OF BACKGROUND DATA: A variety of ovariectomized animals has been used to study...... osteoporosis. Most experimental spine fusions were based on normal animals, and there is a great need for suitable large animal models with adequate bone size that closely resemble osteoporosis in humans. METHODS: Eighteen female skeletal mature sheep were randomly allocated into 3 groups, 6 each. Group 1 (GC......-1) received prednisolone (GC) treatment (0.60 mg/kg/day, 5 times weekly) for 7 months. Group 2 (GC-2) received the same treatment as GC-1 for 7 months followed by 3 months without treatment. Group 3 was left untreated and served as the controls. All sheep received restricted diet with low calcium...

  10. Transplantation of bone marrow mononuclear cells modulates hippocampal expression of growth factors in chronically epileptic animals.

    Science.gov (United States)

    Zanirati, Gabriele; Azevedo, Pamella Nunes; Marinowic, Daniel Rodrigo; Rodrigues, Felipe; de Oliveira Dias, Ana Christina; Venturin, Gianina Teribele; Greggio, Samuel; Simão, Fabrício; DaCosta, Jaderson Costa

    2015-05-01

    In previous studies, transplantation of bone marrow mononuclear cells (BMMCs) in epileptic animals has been found to be neuroprotective. However, the mechanism by which the BMMCs act remains unclear. We hypothesize that BMMCs may provide neuroprotection to the epileptic brain through trophic support. To test our hypothesis, we studied the temporal expression of neurotrophins after BMMC transplantation in the epileptic rat hippocampus. Chronically epileptic rats were intravenously transplanted with 1 × 10(7) BMMCs isolated from GFP transgenic mice. Expression levels of BDNF, GDNF, NGF, VEGF, and TGF-β1, and their receptors, were evaluated by ELISA and/or qRT-PCR analysis. Our data revealed increased protein expression of BDNF, GDNF, NGF, and VEGF and reduced levels of TGF-β1 in the hippocampus of transplanted epileptic animals. Additionally, an increase in the mRNA expression of BDNF, GDNF, and VEGF, a reduction in TGF-β1, and a decrease in mRNA levels of the TrkA and TGFR-β1 receptors were also observed. The gain provided by transplanted BMMCs in the epileptic brain may be related to the ability of these cells in modulating the network of neurotrophins and angiogenic signals. © 2015 John Wiley & Sons Ltd.

  11. Performance of the first Japanese large-scale facility for radon inhalation experiments with small animals

    International Nuclear Information System (INIS)

    Ishimori, Y.; Mitsunobu, F.; Yamaoka, K.; Tanaka, H.; Kataoka, T.; Sakoda, A.

    2011-01-01

    A radon test facility for small animals was developed in order to increase the statistical validity of differences of the biological response in various radon environments. This paper illustrates the performances of that facility, the first large-scale facility of its kind in Japan. The facility has a capability to conduct approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups with five independent cages each. Different radon concentrations in each animal chamber group are available. Because the first target of this study is to examine the in vivo behaviour of radon and its effects, the major functions to control radon and to eliminate thoron were examined experimentally. Additionally, radon progeny concentrations and their particle size distributions in the cages were also examined experimentally to be considered in future projects. (authors)

  12. Scalable Electrophysiology in Intact Small Animals with Nanoscale Suspended Electrode Arrays

    OpenAIRE

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Ben W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-01-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires low-throughput and invasive dissections. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the fi...

  13. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  14. Direct measurement of local oxygen concentration in the bone marrow of live animals

    Science.gov (United States)

    Spencer, Joel A.; Ferraro, Francesca; Roussakis, Emmanuel; Klein, Alyssa; Wu, Juwell; Runnels, Judith M.; Zaher, Walid; Mortensen, Luke J.; Alt, Clemens; Turcotte, Raphaël; Yusuf, Rushdia; Côté, Daniel; Vinogradov, Sergei A.; Scadden, David T.; Lin, Charles P.

    2014-04-01

    Characterization of how the microenvironment, or niche, regulates stem cell activity is central to understanding stem cell biology and to developing strategies for the therapeutic manipulation of stem cells. Low oxygen tension (hypoxia) is commonly thought to be a shared niche characteristic in maintaining quiescence in multiple stem cell types. However, support for the existence of a hypoxic niche has largely come from indirect evidence such as proteomic analysis, expression of hypoxia inducible factor-1α (Hif-1α) and related genes, and staining with surrogate hypoxic markers (for example, pimonidazole). Here we perform direct in vivo measurements of local oxygen tension (pO2) in the bone marrow of live mice. Using two-photon phosphorescence lifetime microscopy, we determined the absolute pO2 of the bone marrow to be quite low (hypoxic as it is perfused with small arteries that are often positive for the marker nestin. These pO2 values change markedly after radiation and chemotherapy, pointing to the role of stress in altering the stem cell metabolic microenvironment.

  15. SU-E-U-02: The Development of a Practical Ultrasonic System for Cross-Sectional Imaging of Small Animals

    Energy Technology Data Exchange (ETDEWEB)

    Kamp, J [Wayne State University, Detroit, MI (United States); Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Malyarenko, E [Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Tessonics Corp, Birmingham, MI (United Kingdom); Chen, D [Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Wydra, A [True Phantoms Solutions, Windsor, ON (Canada); University of Windsor - Institute for Diagnostic Imaging Research, Windsor, ON (Canada); Maev, R [Wayne State University, Detroit, MI (United States); Karmanos Cancer Institute - International Imaging Center, Detroit, MI (United States); Tessonics Corp, Birmingham, MI (United Kingdom); True Phantoms Solutions, Windsor, ON (Canada); University of Windsor - Institute for Diagnostic Imaging Research, Windsor, ON (Canada)

    2015-06-15

    Purpose: To test the feasibility of developing a practical medium frequency ultrasound tomography method for small animal imaging. The ability to produce cross-sectional or full body images of a live small animal using a low-cost tabletop ultrasound scanner without any special license would be very beneficial to long term biological studies, where repeated scanning is often required over an extended period of time. Methods: The cross sectional images were produced by compounding multiple B-scans of a laboratory phantom or an animal acquired at different projection angles. Two imaging systems were used to test the concept. The first system included a programmable 64-channel phased array controller driving a 128-channel, 5–10 MHz linear probe to produce 143 B-Mode projections of the spinning object. The second system designed and manufactured in house, produced 64 or 128 B-Mode projections with a single unfocused 8 MHz transducer scanning with a 0.116 mm step size. Results: The phased array system provided good penetration through the phantoms/mice (with the exception of the lungs) and allowed to acquire data in a very short time. The cross-sectional images have enough resolution and dynamic range to detect both high- and low-contrast organs. The single transducer system takes longer to scan, and the data require more sophisticated processing. To date, our images allow seeing details as small as 1–2 mm in the phantoms and in small animals, with the contrast mostly due to highly reflecting bones and air inclusions. Conclusion: The work indicates that very detailed and anatomically correct images can be created by relatively simple and inexpensive means. With more advanced algorithms and improved system design, scan time can be reduced considerably, enabling high-resolution full 3D imaging. This will allow for quick and easy scans that can help monitor tumor growth and/or regression without contributing any dose to the animal. The authors would like to acknowledge

  16. The effects of honey (Apis dorsata) supplements on increased bone strength in ovariectomized rat as animal model of osteoporosis

    Science.gov (United States)

    Yudaniayanti, Ira Sari; Primarizky, Hardany; Nangoi, Lianny

    2018-04-01

    Osteoporosis is a chronic skeletal disease characterized by low bone mass and microarchitectural deterioration with a consequent increase in bone fragility and fracture risk. The aim of the study was to evaluate the effects of honey (Apis dorsata) supplements on increased bone strength in ovariectomized rat as animal models of osteoporosis. Twenty female rats at 3 months of age, weighing 150-200 g were used in the study. The rats were divided into five groups (n=4) : Sham operation group (SH); ovariectomy group no treatment(OVX); ovariectomy with treatment Apis dorsata 1g/Kg BW (AD-1); ovariectomy with treatment Apis dorsata 2g/Kg BW (AD-2); ovariectomy with treatment Apis dorsata 4g/Kg BW (AD-3). The treatment started to be given the next day after ovariectomy operation for 12 weeks. The Rats were sacrified within 12 weeks, and then the right femur were taken bone strength test. Based on the statistical analysis of the bone strength test, the greatest score belongs to the Sham operation group (SH) that have significant difference (p0,05). In conclusion, honey (Apis dorsata) supplements has the effect of increasing bone strength in ovariectomized rat as animal models of osteoporosis, so that honey (Apis dorsata) supplements has the potential to be used as an alternative treatment for osteoporosis.

  17. SU-E-T-124: Anthropomorphic Phantoms for Confirmation of Linear Accelerator Based Small Animal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Perks, J; Benedict, S [UC Davis Cancer Center, Sacramento, CA (United States); Lucero, S [UC Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specifically mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.

  18. Role of the small integrin-binding ligand N-linked glycoprotein (SIBLING), bone sialoprotein (BSP) in bone development and remodeling.

    OpenAIRE

    Malaval, L.; Aubin, J.; Vico, L.

    2009-01-01

    14 pages; International audience; Members of the “small, integrin binding ligand, N-linked glycoprotein” (SIBLING) family, which have both mineral binding and cell binding (integrins) abilities, appear as potent regulators of bone mineralisation and remodeling. Among these, osteopontin (OPN) and bone sialoprotein (BSP) are highly expressed in early bone. Gene knockout of OPN results in increased mineralisation and a resorption defect making mutant mice unable to respond to such challenges as ...

  19. Accessories for detention and protection used in small animals radiation therapy

    International Nuclear Information System (INIS)

    Vettorato, Michel Campos; Vulcano, Luiz Carlos; Fernandes, Marco Antonio Rodrigues

    2016-01-01

    Radiation therapy is a medical method well established in the treatment of cancer in veterinary medicine worldwide. The radiotherapy protocols applied in animals vary according to several factors. In most procedures require sedation or anesthesia of the animal and this fact imposes the use of immobilization accessories specially developed for the different species of animals and treated as their specified procedures. Therefore, this study aims to describe the types of accessories used for immobilization and for the protection of small animals undergoing radiotherapy. For its development a literature search was performed by search sites like Google Scholar, Scielo, Bireme, PubMed, and consultations in books campus library Botucatu UNESP. Despite the limitations of each accessory rated this review, it was possible to identify the use of each and how this can be advantageous for the treatment of animals undergoing radiation therapy. (author)

  20. Development of a SiPM-based PET imaging system for small animals

    International Nuclear Information System (INIS)

    Lu, Yanye; Yang, Kun; Zhou, Kedi; Zhang, Qiushi; Pang, Bo; Ren, Qiushi

    2014-01-01

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development

  1. Development of a SiPM-based PET imaging system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yanye [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Yang, Kun, E-mail: yangkun9999@hotmail.com [Department of Control Technology and Instrumentation, College of Quality and Technical Supervision, Hebei University, Baoding, 071000 (China); Zhou, Kedi; Zhang, Qiushi; Pang, Bo [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ren, Qiushi, E-mail: renqsh@coe.pku.edu.cn [Department of Biomedicine and Engineering, College of Engineering, Peking University, Beijing 100871 (China)

    2014-04-11

    Advances in small animal positron emission tomography (PET) imaging have been accelerated by many new technologies such as the successful incorporation of silicon photomultiplier (SiPM). In this paper, we have developed a compact, lightweight PET imaging system that is based on SiPM detectors for small animals imaging, which could be integrated into a multi-modality imaging system. This PET imaging system consists of a stationary detector gantry, a motor-controlled animal bed module, electronics modules, and power supply modules. The PET detector, which was designed as a multi-slice circular ring geometry of 27 discrete block detectors, is composed of a cerium doped lutetium–yttrium oxyorthosilicate (LYSO) scintillation crystal and SiPM arrays. The system has a 60 mm transaxial field of view (FOV) and a 26 mm axial FOV. Performance tests (e.g. spatial resolution, energy resolution, and sensitivity) and phantom and animal imaging studies were performed to evaluate the imaging performance of the PET imaging system. The performance tests and animal imaging results demonstrate the feasibility of an animal PET system based on SiPM detectors and indicate that SiPM detectors can be promising photodetectors in animal PET instrumentation development.

  2. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation

    International Nuclear Information System (INIS)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Wong, John; Iordachita, Iulian; Siewerdsen, Jeffrey

    2015-01-01

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal (‘tubular’ geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal (‘pancake’ geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry

  3. Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation.

    Science.gov (United States)

    Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Iordachita, Iulian; Siewerdsen, Jeffrey; Wong, John

    2015-07-07

    The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal ('tubular' geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal ('pancake' geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry, respectively.

  4. Using Hydroxyapatite-Gelatin Scaffold Seeded with Bone Marrow Stromal Cells as a Bone Graft in Animal Model

    Directory of Open Access Journals (Sweden)

    Mahsoumeh Behruzi

    2016-11-01

    Full Text Available Background: Nowadays, composite scaffolds with some desired characteristics have a numerous applications in hard tissue engineering. In present study, the role of composite hydroxyapatite - gelatin was examined in both alone and coated by Bone Marrow Stromal Stem Cells (BMSCs conditions in the process of healing bone defects, reduction of time repair and the immune response of body by laboratory studies (in vitro and in vivo on the skull of adult rats as well. Materials and Methods: In present study, nano-hydroxyapatite powder and gelatin were used to provide nano-hydroxyapatite-gelatin scaffold, BMSCs were isolated by Flushing method. Fifteen adult male Wistar rats weighing 250-200 g were used. Studing groups included bone defect with hydroxyapatite-gelatin scaffold, bone defect with hydroxyapatite-gelatin with BMSCs and bone defects without scaffolding as a controlwhich were examined after a week and a month after surgery. MTT assay was used in order to evaluation of biocompatibility of scaffolds. To confirm the healing progress trend and the presence of inflammatory cells we used hematoxylin-eosin and we used Masson's trichrome staining in order to study of synthesis of collagen fibers. Results: The results of MTT showed that the scaffold has no toxic effects on stromal cells. The first signs of ossification in hydroxyapatite-gelatin with BMSCs cells group, appeared in the first week. However, in the fourth week, ossification was completed and the scaffold remaining was found as embedded islands in the spongy bone tissue. The greatest number of lymphocytes was observed in the experimental group after one week of planting scaffold. Conclusion: it seems that Hydroxyapatite-gelatin scaffold coated with BMSCs cells has a potential role in the healing process of bone and it can be suitable as a therapeutic strategy to repair extensive bone lesions.

  5. Primary functions of the first Japanese large-scale facility for exposing small animals to radon

    International Nuclear Information System (INIS)

    Ishimori, Yuu; Tanaka, Hiroshi; Mitsunobu, Fumihiro; Yamaoka, Kiyonori; Kataoka, Takahiro; Sakoda, Akihiro

    2010-01-01

    The Japan Atomic Energy Agency (JAEA) and Okayama University have carried out the experimental animal study and its related studies since 2007 in order to examine the physiological effects of radon in detail. Thus, a radon test facility for small animals was developed in order to increase the statistical certainty of our animal tests. This paper illustrates the performances of that facility, the first large-scale facility of its types in Japan. The facility has a potential of approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups each of which consists of five independent cages. Different radon concentrations in each animal chamber group are available. The major functions of the facility controlling radon and avoiding thoron were shown theoretically and experimentally. The relative standard deviation of radon concentration at the highest concentration group was about 5%, although the lower concentration groups seemed to be affected by variations in background radon. (author)

  6. Development of computational small animal models and their applications in preclinical imaging and therapy research

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Tianwu [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211 (Switzerland); Geneva Neuroscience Center, Geneva University, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB (Netherlands)

    2016-01-15

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  7. Techniques necessary for multiple tracer quantitative small-animal imaging studies

    International Nuclear Information System (INIS)

    Sharp, Terry L.; Dence, Carmen S.; Engelbach, John A.; Herrero, Pilar; Gropler, Robert J.; Welch, Michael J.

    2005-01-01

    Introduction: An increasing number and variety of studies on rodent models are being conducted using small-animal positron emission tomography scanners. We aimed to determine if animal handling techniques could be developed to perform routine animal imaging in a timely and efficient manner and with minimal effect on animal physiology. These techniques need to be reproducible in the same animal while maintaining hemodynamic and physiological stability. Methods: The necessary techniques include (a) the use of inhalant anesthesia, (b) arterial and venous cannulation for multiple tracer administrations and blood sampling, (c) development of small-volume analytic columns and techniques and (d) measurement of the physiological environment during the imaging session. Results: We provide an example of a cardiac imaging study using four radiotracers ( 15 O-water, 1-[ 11 C]-acetate, 1-[ 11 C]-palmitate and 1-[ 11 C]-glucose) injected into normal rats. Plasma substrates, CO 2 production and total metabolites were measured. The animals remained anesthetized over the entire imaging session, and their physiological state was maintained. Conclusion: The intrastudy stability of the physiological measurements and substrate levels and interstudy reproducibility of the measurements are reported

  8. Development of computational small animal models and their applications in preclinical imaging and therapy research.

    Science.gov (United States)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

  9. Development of computational small animal models and their applications in preclinical imaging and therapy research

    International Nuclear Information System (INIS)

    Xie, Tianwu; Zaidi, Habib

    2016-01-01

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future

  10. Automated analysis of small animal PET studies through deformable registration to an atlas

    NARCIS (Netherlands)

    Gutierrez, Daniel F.; Zaidi, Habib

    This work aims to develop a methodology for automated atlas-guided analysis of small animal positron emission tomography (PET) data through deformable registration to an anatomical mouse model. A non-rigid registration technique is used to put into correspondence relevant anatomical regions of

  11. Precise image-guided irradiation of small animals: a flexible non-profit platform

    International Nuclear Information System (INIS)

    Tillner, Falk; Thute, Prasad; Löck, Steffen; Dietrich, Antje; Fursov, Andriy; Haase, Robert; Lukas, Mathias; Krause, Mechthild; Baumann, Michael; Bütof, Rebecca; Enghardt, Wolfgang; Rimarzig, Bernd; Sobiella, Manfred

    2016-01-01

    Preclinical in vivo studies using small animals are essential to develop new therapeutic options in radiation oncology. Of particular interest are orthotopic tumour models, which better reflect the clinical situation in terms of growth patterns and microenvironmental parameters of the tumour as well as the interplay of tumours with the surrounding normal tissues. Such orthotopic models increase the technical demands and the complexity of preclinical studies as local irradiation with therapeutically relevant doses requires image-guided target localisation and accurate beam application. Moreover, advanced imaging techniques are needed for monitoring treatment outcome. We present a novel small animal image-guided radiation therapy (SAIGRT) system, which allows for precise and accurate, conformal irradiation and x-ray imaging of small animals. High accuracy is achieved by its robust construction, the precise movement of its components and a fast high-resolution flat-panel detector. Field forming and x-ray imaging is accomplished close to the animal resulting in a small penumbra and a high image quality. Feasibility for irradiating orthotopic models has been proven using lung tumour and glioblastoma models in mice. The SAIGRT system provides a flexible, non-profit academic research platform which can be adapted to specific experimental needs and therefore enables systematic preclinical trials in multicentre research networks. (paper)

  12. Performance evaluation of a mouse-sized camera for dynamic studies in small animals

    International Nuclear Information System (INIS)

    Loudos, George; Majewski, Stan; Wojcik, Randy; Weisenberger, Andrew; Sakellios, Nicolas; Nikita, Konstantina; Uzunoglu, Nikolaos; Bouziotis, Penelope; Varvarigou, Alexandra

    2007-01-01

    A mouse sized camera has been built in terms of collaboration between the presenting institutions. The system is used for the performance of dynamic studies in small animals, in order to evaluate novel radiopharmaceuticals. The active area of the detector is approximately 48x96 mm allowing depiction of the entire mouse in a single view. The system is based on two flat-panel Hamamatsu H8500 position sensitive photomultiplier tubes (PSPMT), a pixellated NaI(Tl) scintillator and a copper-beryllium (CuBe) parallel-hole collimator. In this work, the evaluation results of the system are presented, using phantoms and small animals injected with conventional radiophrmaceuticals. Average resolution was ∼1.6 mm on the collimator surface and increased to ∼4.1 mm in 12 cm distance from the detector. The average energy resolution was measured and found to be ∼15.6% for Tc 99m . Results from imaging thin capillaries demonstrated system's high resolution and sensitivity in activity variations was shown. Initial dynamic studies have been carried out in small animals injected with Tc 99m -DTPA and Tc 99m -MDP. The results show system's ability to perform kinetic imaging in small animals

  13. Management of occupational health risks in small-animal veterinary practices.

    Science.gov (United States)

    D'Souza, Eva; Barraclough, Richard; Fishwick, David; Curran, Andrew

    2009-08-01

    Small-animal work is a major element of veterinary practice in the UK and may be hazardous, with high levels of work-related injuries and ill-health reported in Australia and USA. There are no studies addressing the management of occupational health risks arising from small-animal work in the UK. To investigate the sources of health and safety information used and how health and safety and 12 specific occupational health risks are managed by practices. A cross-sectional postal survey of all small-animal veterinary practices in Hampshire. A response was mandatory as this was a Health & Safety Executive (HSE) inspection activity. A total of 118 (100%) practices responded of which 93 were eligible for inclusion. Of these, 99 and 86%, respectively, were aware of the Royal College of Veterinary Surgeons (RCVS) practice standards and had British Small Animal Veterinary Association (BSAVA) staff members, while only 51% had previous contact with HSE (publications, advice and visit). Ninety per cent had health and safety policies, but only 31% had trained responsible staff in health and safety. Specific health hazards such as occupational allergens and computer use were relatively overlooked both by practices and the RCVS/BSAVA guidance available in 2002. Failings in active health risk management systems could be due to a lack of training to ensure competence in those with responsibilities. Practices rely on guidance produced by their professional bodies. Current RCVS guidance, available since 2005, has remedied some previous omissions, but further improvements are recommended.

  14. Small animal positron emission tomography imaging and in vivo studies of atherosclerosis

    DEFF Research Database (Denmark)

    Hag, Anne Mette Fisker; Ripa, Rasmus Sejersten; Pedersen, Sune Folke

    2013-01-01

    Atherosclerosis is a growing health challenge globally, and despite our knowledge of the disease has increased over the last couple of decades, many unanswered questions remain. As molecular imaging can be used to visualize, characterize and measure biological processes at the molecular and cellu...... knowledge obtained from in vivo positron emission tomography studies of atherosclerosis performed in small animals....

  15. Nigerian Veterinary Journal The record of J 14small animal trauma ...

    African Journals Online (AJOL)

    base for the establishment of protocols for trauma patient care. Trauma cases ranked first and accounted fOT46.3% of all small animal surgical cases presented during the period. Species involvement markedly favoured the canine species. Incidence of trauma was significantly higher (1)<0.05) in males (60.5%) and younger.

  16. Current status and future perspectives of in vivo small animal imaging using radiolabeled nanoparticles

    International Nuclear Information System (INIS)

    Loudos, George; Kagadis, George C.; Psimadas, Dimitris

    2011-01-01

    Small animal molecular imaging is a rapidly expanding efficient tool to study biological processes non-invasively. The use of radiolabeled tracers provides non-destructive, imaging information, allowing time related phenomena to be repeatedly studied in a single animal. In the last decade there has been an enormous progress in related technologies and a number of dedicated imaging systems overcome the limitations that the size of small animal possesses. On the other hand, nanoparticles (NPs) gain increased interest, due to their unique properties, which make them perfect candidates for biological applications. Over the past 5 years the two fields seem to cross more and more often; radiolabeled NPs have been assessed in numerous pre-clinical studies that range from oncology, till HIV treatment. In this article the current status in the tools, applications and trends of radiolabeled NPs reviewed.

  17. The effect of an osteolytic tumor on the three-dimensional trabecular bone morphology in an animal model

    International Nuclear Information System (INIS)

    Kurth, A.A.; Mueller, R.

    2001-01-01

    Objective. To investigate the application of micro-computed tomography (μCT) for the assessment of density differences and deterioration of three-dimensional architecture of trabecular bone in an experimental rat model for tumor- induced osteolytic defects.Design and materials. Walker carcinosarcoma 256 malignant breast cancer cells (W256) were surgically implanted into the medullary canal of the left femur of 15 4-month-old rats. Twenty-eight days after surgery all animals were killed and both femora from each rat were harvested. A total of 30 specimens (left and right femur) were scanned in a desk-top μCT imaging system (μCT 20, Scanco Medical) to assess densitometric and architectural parameters. For each specimen a total of 200 micro-tomographic slices with a resolution of 30 μm in the distal metaphysis was taken. Bone mineral content (BMC) was analyzed for both cortical and trabecular bone (ctBMC), and for trabecular bone only (tBMC). Architectural indices (BV/TV, Tb.N, Tb.Th, Tb.Sp) according to standard definitions used in histomorphometry were calculated for trabecular bone.Results. The quantitative analysis of density parameters revealed significantly (P<0.001) lower values for ctBMC and tBMC in the tumor-bearing group (T) of 26% and 31%, respectively, compared with the contralateral control group. The quantitative analysis revealed significant (P<0.001) changes in the architectural parameters in the tumor-bearing bones compared with the contralateral control group: BV/TV was 30% lower, Tb.N and BS/TV decreased by 24% and 21%, respectively, Tb.Th. decreased by 10% and Tb.Sp. increased by 94%.Conclusions. This study demonstrates that μCT is able to provide three-dimensional parameters of bone mass and trabecular structure in an animal model for tumor-induced bone loss. Recent advances in therapeutic approaches for skeletal diseases such as osteoporosis and metastatic bone disease rely on an understanding of the effects of the agents on the mechanical

  18. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  19. Palmitic Acid Reduces Circulating Bone Formation Markers in Obese Animals and Impairs Osteoblast Activity via C16-Ceramide Accumulation.

    Science.gov (United States)

    Alsahli, Ahmad; Kiefhaber, Kathryn; Gold, Tziporah; Muluke, Munira; Jiang, Hongfeng; Cremers, Serge; Schulze-Späte, Ulrike

    2016-05-01

    Obesity and impaired lipid metabolism increase circulating and local fatty acid (FA) levels. Our previous studies showed that a high high-saturated -fat diet induced greater bone loss in mice than a high high-unsaturated-fat diet due to increased osteoclast numbers and activity. The impact of elevated FA levels on osteoblasts is not yet clear. We induced obesity in 4 week old male mice using a palmitic acid (PA)- or oleic acid (OA)-enriched high fat high-fat diet (HFD) (20 % of calories from FA), and compared them to mice on a normal (R) caloric diet (10 % of calories from FA). We collected serum to determine FA and bone metabolism marker levels. Primary osteoblasts were isolated; cultured in PA, OA, or control (C) medium; and assessed for mineralization activity, gene expression, and ceramide levels. Obese animals in the PA and OA groups had significantly lower serum levels of bone formation markers P1NP and OC compared to normal weight animals (*p < 0.001), with the lowest marker levels in animals on an PA-enriched HFD (*p < 0.001). Accordingly, elevated levels of PA significantly reduced osteoblast mineralization activity in vitro (*p < 0.05). Elevated PA intake significantly increased C16 ceramide accumulation. This accumulation was preventable through inhibition of SPT2 (serine palmitoyl transferase 2) using myriocin. Elevated levels of PA reduce osteoblast function in vitro and bone formation markers in vivo. Our findings suggest that saturated PA can compromise bone health by affecting osteoblasts, and identify a potential mechanism through which obesity promotes bone loss.

  20. Partial body irradiation of small laboratory animals with an industrial X-ray tube

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas; Grohmann, Carsten; Schumacher, Udo

    2014-01-01

    Dedicated precise small laboratory animal irradiation sources are needed for basic cancer research and to meet this need expensive high precision radiation devices have been developed. To avoid such expenses a cost efficient way is presented to construct a device for partial body irradiation of small laboratory animals by adding specific components to an industrial X-ray tube. A custom made radiation field tube was added to an industrial 200 kV X-ray tube. A light field display as well as a monitor ionization chamber were implemented. The field size can rapidly be changed by individual inserts of MCP96 that are used for secondary collimation of the beam. Depth dose curves and cross sectional profiles were determined with the use of a custom made water phantom. More components like positioning lasers, a custom made treatment couch, and a commercial isoflurane anesthesia unit were added to complete the system. With the accessories described secondary small field sizes down to 10 by 10 mm 2 (secondary collimator size) could be achieved. The dosimetry of the beam was constructed like those for conventional stereotactical clinical linear accelerators. The water phantom created showed an accuracy of 1 mm and was well suited for all measurements. With the anesthesia unit attached to the custom made treatment couch the system is ideal for the radiation treatment of small laboratory animals like mice. It was feasible to shrink the field size of an industrial X-ray tube from whole animal irradiation to precise partial body irradiation of small laboratory animals. Even smaller secondary collimator sizes than 10 by 10 mm 2 are feasible with adequate secondary collimator inserts. Our custom made water phantom was well suited for the basic dosimetry of the X-ray tube.

  1. The zoonotic potential of Clostridium difficile from small companion animals and their owners.

    Science.gov (United States)

    Rabold, Denise; Espelage, Werner; Abu Sin, Muna; Eckmanns, Tim; Schneeberg, Alexander; Neubauer, Heinrich; Möbius, Nadine; Hille, Katja; Wieler, Lothar H; Seyboldt, Christian; Lübke-Becker, Antina

    2018-01-01

    Clostridium difficile infections (CDI) in humans range from asymptomatic carriage to life-threatening intestinal disease. Findings on C. difficile in various animal species and an overlap in ribotypes (RTs) suggest potential zoonotic transmission. However, the impact of animals for human CDI remains unclear. In a large-scale survey we collected 1,447 fecal samples to determine the occurrence of C. difficile in small companion animals (dogs and cats) and their owners and to assess potential epidemiological links within the community. The Germany-wide survey was conducted from July 2012-August 2013. PCR ribotyping, Multilocus VNTR Analysis (MLVA) and PCR detection of toxin genes were used to characterize isolated C. difficile strains. A database was defined and logistic regression used to identify putative factors associated with fecal shedding of C. difficile. In total, 1,418 samples met the inclusion criteria. The isolation rates for small companion animals and their owners within the community were similarly low with 3.0% (25/840) and 2.9% (17/578), respectively. PCR ribotyping revealed eight and twelve different RTs in animals and humans, respectively, whereas three RTs were isolated in both, humans and animals. RT 014/0, a well-known human hospital-associated lineage, was predominantly detected in animal samples. Moreover, the potentially highly pathogenic RTs 027 and 078 were isolated from dogs. Even though, C. difficile did not occur simultaneously in animals and humans sharing the same household. The results of the epidemiological analysis of factors associated with fecal shedding of C. difficile support the hypothesis of a zoonotic potential. Molecular characterization and epidemiological analysis revealed that the zoonotic risk for C. difficile associated with dogs and cats within the community is low but cannot be excluded.

  2. Animal Bone Remnants from Trench CLXII of the Bolgar City Site: Some New Methods of Archaeozoological Materials Processing and Evaluation

    Directory of Open Access Journals (Sweden)

    Yavorskaya Lilia V.

    2012-03-01

    Full Text Available It is for the first time in the study of animal bone remnants from the Bolgar city site that modern techniques have been applied, which have made it possible to solve archaeological and historical problems rather than purely biological ones. A detailed description of the work process based on these techniques and of the results obtained is offered. In particular, it has been found out that the cattle intended for slaughter in Bolgar had not been bred within the city limits but rather supplied from outside. Also for the first time, a change in the distribution structure of finds of wild animals’ bones as per chronological periods has been recorded.

  3. Attitudes of Austrian veterinarians towards euthanasia in small animal practice: impacts of age and gender on views on euthanasia

    OpenAIRE

    Hartnack, Sonja; Springer, Svenja; Pittavino, Marta; Grimm, Herwig

    2016-01-01

    Background Euthanasia of pets has been described by veterinarians as ?the best and the worst? of the profession. The most commonly mentioned ethical dilemmas veterinarians face in small animal practice are: limited treatment options due to financial constraints, euthanizing of healthy animals and owners wishing to continue treatment of terminally ill animals. The aim of the study was to gain insight into the attitudes of Austrian veterinarians towards euthanasia of small animals. This include...

  4. In vivo fluorescence enhanced optical tomography reconstruction of lung cancer of non immersed small animals

    Science.gov (United States)

    Hervé, L.; Koenig, A.; Da Silva, A.; Berger, M.; Boutet, J.; Dinten, J. M.; Peltié, P.; Rizo, P.

    2007-02-01

    Fluorescence enhanced diffuse optical tomography (fDOT) is envisioned to be useful to collect functional information from small animal models. For oncology applications, cancer-targeted fluorescent markers can be used as a surrogate of the cancer activity. We are developing a continuous wave fDOT bench intended to be integrated in systems dedicated to whole body small animal fluorescence analyses. The focus is currently put on the reconstruction of non immersed small animals imaged by a CCD camera. The reconstruction stage already corrects the tissue heterogeneity artifacts through the computation of an optical heterogeneity map. We will show how this formalism coupled with the determination of the animal boundaries performed by a laser scanner, can be used to manage non contact acquisitions. The time of reconstruction for a 10 × 9 laser source positions, 45 × 40 detector elements and 14 × 11 × 14 mesh voxels is typically 10 minutes on a 3GHz PCs corresponding to the acquisition time allowing the two tasks to be performed in parallel. The system is validated on an in vivo experiment performed on three healthy nude mice and a mouse bearing a lung tumor at 10, 12 and 14 days after implantation allowing the follow up of the disease. The 3D fluorescence reconstructions of this mouse are presented and the total fluorescence amounts are compared.

  5. Ethical dilemmas encountered by small animal veterinarians: characterisation, responses, consequences and beliefs regarding euthanasia.

    Science.gov (United States)

    Kipperman, Barry; Morris, Patricia; Rollin, Bernard

    2018-05-12

    Small animal veterinarians' opinions were investigated regarding the frequency and nature of ethical dilemmas encountered, beliefs regarding euthanasia and balancing client and animal interests, prevalence and value of ethics training and proposals to mitigate the stressful effects of ethical dilemmas. The majority (52 per cent) of 484 respondents in the USA indicated via an online survey experiencing an ethical dilemma regarding the interests of clients and those of their patients at least weekly. Scenarios involving client financial concerns were commonly reported causes of ethical conflicts. While only 20 per cent of respondents indicated that other practitioners prioritise patient interests, 50 per cent of respondents characterised their own behaviour as prioritising patients. Most respondents (52 per cent) reported that ethical dilemmas are the leading cause, or are one of many equal causes, of work-related stress. Less experienced practitioners, general practitioners and associate veterinarians were more likely to encounter situations they defined as ethical dilemmas, and female respondents were more likely to find ethical dilemmas stressful. Most small animal veterinarians experience ethical dilemmas regularly, which contribute to moral stress. Results suggested that most small animal practitioners believe that greater awareness of moral stress and providing training in ethical theories and tools for coping with ethical dilemmas can ameliorate moral stress. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. 9.4 T small animal MRI using clinical components for direct translational studies.

    Science.gov (United States)

    Felder, Jörg; Celik, A Avdo; Choi, Chang-Hoon; Schwan, Stefan; Shah, N Jon

    2017-12-28

    Magnetic resonance is a major preclinical and clinical imaging modality ideally suited for longitudinal studies, e.g. in pharmacological developments. The lack of a proven platform that maintains an identical imaging protocol between preclinical and clinical platforms is solved with the construction of an animal scanner based on clinical hard- and software. A small animal magnet and gradient system were connected to a clinical MR system. Several hardware components were either modified or built in-house to achieve compatibility. The clinical software was modified to account for the different field-of-view of a preclinical MR system. The established scanner was evaluated using clinical QA protocols, and platform compatibility for translational research was verified against clinical scanners of different field strength. The constructed animal scanner operates with the majority of clinical imaging sequences. Translational research is greatly facilitated as protocols can be shared between preclinical and clinical platforms. Hence, when maintaining sequences parameters, maximum similarity between pulses played out on a human or an animal system is maintained. Coupling of a small animal magnet with a clinical MR system is a flexible, easy to use way to establish and advance translational imaging capability. It provides cost and labor efficient translational capability as no tedious sequence reprogramming between moieties is required and cross-platform compatibility of sequences facilitates multi-center studies.

  7. Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours

    International Nuclear Information System (INIS)

    Novak, P; Moros, E G; Parry, J J; Rogers, B E; Myerson, R J; Zeug, A; Locke, J E; Rossin, R; Straube, W L; Singh, A K

    2005-01-01

    An external local ultrasound (US) system was developed to induce controlled hyperthermia of subcutaneously implanted tumours in small animals (e.g., mice and rats). It was designed to be compatible with a small animal positron emission tomography scanner (microPET) to facilitate studies of hyperthermia-induced tumour re-oxygenation using a PET radiopharmaceutical, but it is applicable for any small animal study requiring controlled heating. The system consists of an acrylic applicator bed with up to four independent 5 MHz planar disc US transducers of 1 cm in diameter, a four-channel radiofrequency (RF) generator, a multiple thermocouple thermometry unit, and a personal computer with custom monitoring and controlling software. Although the system presented here was developed to target tumours of up to 1 cm in diameter, the applicator design allows for different piezoelectric transducers to be exchanged and operated within the 3.5-6.5 MHz band to target different tumour sizes. Temperature feedback control software was developed on the basis of a proportional-integral-derivative (PID) approach when the measured temperatures were within a selectable temperature band about the target temperature. Outside this band, an on/off control action was applied. Perfused tissue-mimicking phantom experiments were performed to determine optimum controller gain constants, which were later employed successfully in animal experiments. The performance of the SAHUS (small animal hyperthermia ultrasound system) was tested using several tumour types grown in thighs of female nude (nu/nu) mice. To date, the system has successfully treated 83 tumours to target temperatures in the range of 41-43 deg. C for periods of 65 min on average

  8. FDG small animal PET permits early detection of malignant cells in a xenograft murine model

    International Nuclear Information System (INIS)

    Nanni, Cristina; Spinelli, Antonello; Trespidi, Silvia; Ambrosini, Valentina; Castellucci, Paolo; Farsad, Mohsen; Franchi, Roberto; Fanti, Stefano; Leo, Korinne di; Tonelli, Roberto; Pession, Andrea; Pettinato, Cinzia; Rubello, Domenico

    2007-01-01

    The administration of new anticancer drugs in animal models is the first step from in vitro to in vivo pre-clinical protocols. At this stage it is crucial to ensure that cells are in the logarithmic phase of growth and to avoid vascular impairment, which can cause inhomogeneous distribution of the drug within the tumour and thus lead to bias in the final analysis of efficacy. In subcutaneous xenograft murine models, positivity for cancer is visually recognisable 2-3 weeks after inoculation, when a certain amount of necrosis is usually already present. The aim of this study was to evaluate the accuracy of FDG small animal PET for the early detection of malignant masses in a xenograft murine model of human rhabdomyosarcoma. A second goal was to analyse the metabolic behaviour of this xenograft tumour over time. We studied 23 nude mice, in which 7 x 10 6 rhabdomyosarcoma cells (RH-30 cell line) were injected in the dorsal subcutaneous tissues. Each animal underwent four FDG PET scans (GE, eXplore Vista DR) under gas anaesthesia. The animals were studied 2, 5, 14 and 20 days after inoculation. We administered 20 MBq of FDG via the tail vein. Uptake time was 60 min, and acquisition time, 20 min. Images were reconstructed with OSEM 2D iterative reconstruction and the target to background ratio (TBR) was calculated for each tumour. Normal subcutaneous tissue had a TBR of 0.3. Necrosis was diagnosed when one or more cold areas were present within the mass. All the animals were sacrificed and histology was available to verify PET results. PET results were concordant with the findings of necropsy and histology in all cases. The incidence of the tumour was 69.6% (16/23 animals); seven animals did not develop a malignant mass. Ten of the 23 animals had a positive PET scan 2 days after inoculation. Nine of these ten animals developed a tumour; the remaining animal became negative, at the third scan. The positive predictive value of the early PET scan was 90% (9/10 animals

  9. Performance characteristics of a small animal PET camera for molecular imaging

    International Nuclear Information System (INIS)

    Hastings, D.L.; Reader, A.J.; Julyan, P.J.; Zweit, J.; Jeavons, A.P.; Jones, T.

    2007-01-01

    The performance of a novel type of animal PET camera, the quad High-Density Avalanche Chamber (HIDAC) was assessed for a non-rotating 16-module system. Spatial resolution was 1.0 mm, and invariant within a standard deviation ≤5%. Absolute sensitivity was 0.95%, and the scatter-background corrected sensitivity was 0.75%. The count rate capability was linear at typical activities used in animal imaging, with a 20% loss at 11.5 MBq. The camera demonstrates small regions of radiotracer uptake with excellent detail in the mouse

  10. Fungal Infections of the Central Nervous System in Small Animals: Clinical Features, Diagnosis, and Management.

    Science.gov (United States)

    Bentley, R Timothy; Taylor, Amanda R; Thomovsky, Stephanie A

    2018-01-01

    Small animal mycoses vary geographically. Different clinical presentations are seen in animals with infection of the central nervous system (CNS), including multifocal meningoencephalomyelitis, intracranial lesions that accompany sinonasal lesions, rapidly progressive ventriculitis, or solitary granuloma of the brain or spinal cord. Systemic, nasal, or extraneural clinical signs are common but, especially in granuloma cases, do not always occur. Surgery may have a diagnostic and therapeutic role in CNS granuloma. There have been recent advancements in serology. Fluconazole, voriconazole, and posaconazole cross the blood-brain barrier, but voriconazole is neurotoxic to cats. Liposomal and lipid-encapsulated formulations of amphotericin B are preferred. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Development of in-vivo micro CT system for small animals

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ki Yong; Lim, Jong Hyeok; Jeong, Young Jo; Park, Jeong Gwon [Institute for Radiological Imaging Science, Iksan (Korea, Republic of); Park, Jung Bung [DRGEM Corp., Seoul (Korea, Republic of); Yoon, Kwon Ha [Institute for Radiological Imaging Science and Medical School of Radiology, Iksan (Korea, Republic of)

    2005-07-01

    Computed tomography system with the spatial resolution of {approx}25 {mu}m has been developed for the application to small animals. This system is designed by gantry-rotation type for minimizing animal movement. To get image with micro-spatial resolution, system characteristic such as geometry between main components of source, specimen and detector, field of view, etc., is described in this paper. The requirements of x-ray spot size and CCD pixel size to approach the resolution are discussed. In-vivo imaging test for mouse is also presented as a result.

  12. Development of in-vivo micro CT system for small animals

    International Nuclear Information System (INIS)

    Nam, Ki Yong; Lim, Jong Hyeok; Jeong, Young Jo; Park, Jeong Gwon; Park, Jung Bung; Yoon, Kwon Ha

    2005-01-01

    Computed tomography system with the spatial resolution of ∼25 μm has been developed for the application to small animals. This system is designed by gantry-rotation type for minimizing animal movement. To get image with micro-spatial resolution, system characteristic such as geometry between main components of source, specimen and detector, field of view, etc., is described in this paper. The requirements of x-ray spot size and CCD pixel size to approach the resolution are discussed. In-vivo imaging test for mouse is also presented as a result

  13. Monitoring of small laboratory animal experiments by a designated web-based database.

    Science.gov (United States)

    Frenzel, T; Grohmann, C; Schumacher, U; Krüll, A

    2015-10-01

    Multiple-parametric small animal experiments require, by their very nature, a sufficient number of animals which may need to be large to obtain statistically significant results.(1) For this reason database-related systems are required to collect the experimental data as well as to support the later (re-) analysis of the information gained during the experiments. In particular, the monitoring of animal welfare is simplified by the inclusion of warning signals (for instance, loss in body weight >20%). Digital patient charts have been developed for human patients but are usually not able to fulfill the specific needs of animal experimentation. To address this problem a unique web-based monitoring system using standard MySQL, PHP, and nginx has been created. PHP was used to create the HTML-based user interface and outputs in a variety of proprietary file formats, namely portable document format (PDF) or spreadsheet files. This article demonstrates its fundamental features and the easy and secure access it offers to the data from any place using a web browser. This information will help other researchers create their own individual databases in a similar way. The use of QR-codes plays an important role for stress-free use of the database. We demonstrate a way to easily identify all animals and samples and data collected during the experiments. Specific ways to record animal irradiations and chemotherapy applications are shown. This new analysis tool allows the effective and detailed analysis of huge amounts of data collected through small animal experiments. It supports proper statistical evaluation of the data and provides excellent retrievable data storage. © The Author(s) 2015.

  14. An automated robot arm system for small animal tissue biopsy under dual-image modality

    International Nuclear Information System (INIS)

    Huang, Y.H.; Wu, T.H.; Lin, M.H.; Yang, C.C.; Guo, W.Y.; Wang, Z.J.; Chen, C.L.; Lee, J.S.

    2006-01-01

    The ability to non-invasively monitor cell biology in vivo is one of the most important goals of molecular imaging. Imaging procedures could be inter-subject performed repeatedly at different investigating stages; thereby need not sacrifice small animals during the entire study period. Thus, the ultimate goal of this study was to design a stereotactic image-guided system for small animals and integrated it with an automatic robot arm for in vivo tissue biopsy analysis. The system was composed of three main parts, including one small animal stereotactic frame, one imaging-fusion software and an automatic robot arm system. The system has been thoroughly evaluated with three components; the robot position accuracy was 0.05±0.02 mm, the image registration accuracy was 0.37±0.18 mm and the system integration was satisfactorily within 1.20±0.39 mm of error. From these results, the system demonstrated sufficient accuracy to guide the micro-injector from the planned delivery routes into practice. The entire system accuracy was limited by the image fusion and orientation procedures, due to its nature of the blurred PET imaging obtained from the small objects. The primary improvement is to acquire as higher resolution as possible the fused imaging for localizing the targets in the future

  15. Anesthesia condition for 18F-FDG imaging of lung metastasis tumors using small animal PET

    International Nuclear Information System (INIS)

    Woo, Sang-Keun; Lee, Tae Sup; Kim, Kyeong Min; Kim, June-Youp; Jung, Jae Ho; Kang, Joo Hyun; Cheon, Gi Jeong; Choi, Chang Woon; Lim, Sang Moo

    2008-01-01

    Small animal positron emission tomography (PET) with 18 F-FDG has been increasingly used for tumor imaging in the murine model. The aim of this study was to establish the anesthesia condition for imaging of lung metastasis tumor using small animal 18 F-FDG PET. Methods: To determine the impact of anesthesia on 18 F-FDG distribution in normal mice, five groups were studied under the following conditions: no anesthesia, ketamine and xylazine (Ke/Xy), 0.5% isoflurane (Iso 0.5), 1% isoflurane (Iso 1) and 2% isoflurane (Iso 2). The ex vivo counting, standard uptake value (SUV) image and glucose SUV of 18 F-FDG in various tissues were evaluated. The 18 F-FDG images in the lung metastasis tumor model were obtained under no anesthesia, Ke/Xy and Iso 0.5, and registered with CT image to clarify the tumor region. Results: Blood glucose concentration and muscle uptake of 18 F-FDG in the Ke/Xy group markedly increased more than in the other groups. The Iso 2 group increased 18 F-FDG uptake in heart compared with the other groups. The Iso 0.5 anesthesized group showed the lowest 18 F-FDG uptake in heart and chest wall. The small size of lung metastasis tumor (2 mm) was clearly visualized by 18 F-FDG image with the Iso 0.5 anesthesia. Conclusion: Small animal 18 F-FDG PET imaging with Iso 0.5 anesthesia was appropriate for the detection of lung metastasis tumor. To acquire 18 F-FDG PET images with small animal PET, the type and level of anesthetic should be carefully considered to be suitable for the visualization of target tissue in the experimental model

  16. Multi-institutional MicroCT image comparison of image-guided small animal irradiators

    Science.gov (United States)

    Johnstone, Chris D.; Lindsay, Patricia; E Graves, Edward; Wong, Eugene; Perez, Jessica R.; Poirier, Yannick; Ben-Bouchta, Youssef; Kanesalingam, Thilakshan; Chen, Haijian; E Rubinstein, Ashley; Sheng, Ke; Bazalova-Carter, Magdalena

    2017-07-01

    To recommend imaging protocols and establish tolerance levels for microCT image quality assurance (QA) performed on conformal image-guided small animal irradiators. A fully automated QA software SAPA (small animal phantom analyzer) for image analysis of the commercial Shelley micro-CT MCTP 610 phantom was developed, in which quantitative analyses of CT number linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, spatial resolution by means of modulation transfer function (MTF), and CT contrast were performed. Phantom microCT scans from eleven institutions acquired with four image-guided small animal irradiator units (including the commercial PXi X-RAD SmART and Xstrahl SARRP systems) with varying parameters used for routine small animal imaging were analyzed. Multi-institutional data sets were compared using SAPA, based on which tolerance levels for each QA test were established and imaging protocols for QA were recommended. By analyzing microCT data from 11 institutions, we established image QA tolerance levels for all image quality tests. CT number linearity set to R 2  >  0.990 was acceptable in microCT data acquired at all but three institutions. Acceptable SNR  >  36 and noise levels  1.5 lp mm-1 for MTF  =  0.2) was obtained at all but four institutions due to their large image voxel size used (>0.275 mm). Ten of the eleven institutions passed the set QA tolerance for geometric accuracy (2000 HU for 30 mgI ml-1). We recommend performing imaging QA with 70 kVp, 1.5 mA, 120 s imaging time, 0.20 mm voxel size, and a frame rate of 5 fps for the PXi X-RAD SmART. For the Xstrahl SARRP, we recommend using 60 kVp, 1.0 mA, 240 s imaging time, 0.20 mm voxel size, and 6 fps. These imaging protocols should result in high quality images that pass the set tolerance levels on all systems. Average SAPA computation time for complete QA analysis for a 0.20 mm voxel, 400 slice Shelley phantom microCT data set

  17. Collagen type I from bovine bone. Effect of animal age, bone anatomy and drying methodology on extraction yield, self-assembly, thermal behaviour and electrokinetic potential.

    Science.gov (United States)

    Ferraro, Vincenza; Gaillard-Martinie, Brigitte; Sayd, Thierry; Chambon, Christophe; Anton, Marc; Santé-Lhoutellier, Véronique

    2017-04-01

    Natural collagen is easily available from animal tissues such as bones. Main limitations reported in the use of natural collagen are heterogeneity and loss of integrity during recovery. However, its natural complexity, functionality and bioactivity still remain to be achieved through synthetic and recombinant ways. Variability of physicochemical properties of collagen extracted from bovine bone by acetic acid was then investigated taking into account endogenous and exogenous factors. Endogenous: bovine's bones age (4 and 7 years) and anatomy (femur and tibia); exogenous: thermal treatments (spray-drying and lyophilisation). Scanning electron microscopy, spectroscopy (EDS, FTIR, UV/Vis and CD), differential scanning calorimetry (DSC), centesimal composition, mass spectrometry, amino acids and zeta-potential analysis were used for the purpose. Age correlated negatively with yield of recovery and positively with minerals and proteoglycans content. Comparing the anatomy, higher yields were found for tibias, and higher stability of tibias collagen in solution was noticed. Whatever the age and the anatomy, collagens were able to renature and to self-assemble into tri-dimensional structures. Nonetheless thermal stability and kinetics of renaturation were different. Variability of natural collagen with bone age and anatomy, and drying methodology, may be a crucial advantage to conceive tailor-made applications in either the biological or technical sector. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Feeding strategies for improving milk production from milch animals owned by small farmers in India

    International Nuclear Information System (INIS)

    Leng, R.A.

    1990-01-01

    Over the last decade the National Dairy Development Board of India has researched and developed feeding strategies for lactating cattle and buffaloes fed on basal forage diets. Depending on the season and climate, these diets are largely mature forage from tropical pastures or crop residues, which are generally low in protein and of relatively low digestibility. Supplementation of the rumen microbial ecosystem with essential nutrients by providing each animal with a urea/molasses block stimulates production by improving feed digestibility, intake and the balance of nutrients available from the feed. Supplementation with a bypass protein to supply the animal directly with additional amino acids stimulates the efficiency of feed utilization by reducing the heat increment of feeding. In hot environments this reduces heat stress and allows feed intake to be maintained. These feeding strategies are now being applied to a large number of milch animals in the herds of small farmers in India. (author). 16 refs, 1 fig., 7 tabs

  19. Characterization of a high-purity germanium detector for small-animal SPECT.

    Science.gov (United States)

    Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E

    2011-09-21

    We present an initial evaluation of a mechanically cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axes. Finally, a flood-corrected flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT.

  20. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    International Nuclear Information System (INIS)

    Lee, Se Ho; Lee, Seung Wook; Han, Su Chul; Park, Seung Woo

    2016-01-01

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study

  1. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Se Ho; Lee, Seung Wook [Pusan National University, Busan (Korea, Republic of); Han, Su Chul; Park, Seung Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2016-05-15

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study.

  2. Carriage of methicillin-resistant Staphylococcus pseudintermedius in small animal veterinarians

    DEFF Research Database (Denmark)

    Paul, Narayan Chandra; Moodley, Arshnee; Ghibaudo, G.

    2011-01-01

    Methicillin-resistant Staphylococcus pseudintermedius (MRSP) is increasingly reported in small animals and cases of human infections have already been described despite its recent emergence in veterinary practice. We investigated the prevalence of MRSP and methicillin-resistant Staphylococcus...... aureus (MRSA) among small animal dermatologists attending a national veterinary conference in Italy. Nasal swabs were obtained from 128 veterinarians, seven of which harboured MRSP (n = 5; 3.9%) or MRSA (n = 2; 1.6%). A follow-up study of two carriers revealed that MRSP persisted for at least 1 month...... by spa typing. Methicillin-resistant isolates were further typed by antimicrobial susceptibility testing, SCCmec and multi-locus sequence typing. Two lineages previously associated with pets were identified among the five MRSP isolates; the European epidemic clone ST71-SCCmec II-III and ST106-SCCmec IV...

  3. A 3D high-resolution gamma camera for radiopharmaceutical studies with small animals

    CERN Document Server

    Loudos, G K; Giokaris, N D; Styliaris, E; Archimandritis, S C; Varvarigou, A D; Papanicolas, C N; Majewski, S; Weisenberger, D; Pani, R; Scopinaro, F; Uzunoglu, N K; Maintas, D; Stefanis, K

    2003-01-01

    The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2 mm in planar and 2-3 mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system.

  4. [Study of migration and distribution of bone marrow cells transplanted animals with B16 melanoma ].

    Science.gov (United States)

    Poveshchenko, A F; Solovieva, A O; Zubareva, K E; Strunkin, D N; Gricyk, O B; Poveshchenko, O V; Shurlygina, A V; Konenkov, V I

    2017-01-01

    Purpose. Reveal features migration and distribution of syngeneic bone marrow cells (BMC) and subpopulations (MSC) after transplantation into the recipient carrier B16 melanoma bodies. Methods. We used mouse male and female C57BL/6 mice. Induction of Tumor Growth: B16 melanoma cells implanted subcutaneously into right hind paw of female C57BL/6 mice at a dose of 2.5 x 105 cells / mouse. migration study in vivo distribution and BMC and MSC was performed using genetic markers - Y-chromosome specific sequence line male C57Bl/6 syngeneic intravenous transplantation in females using the polymerase chain reaction (PCR) in real time on Authorized Termal Cycler - Light Cycler 480 II / 96 (Roche). Introduction suspension of unseparated bone marrow cells, mesenchymal stem cells from donor to recipient male mice (syngeneic recipient female C57BL/6), followed by isolation of recipients of organs was performed at regular intervals, then of organ recipients isolated DNA. Results. It was shown that bone marrow cells positive for Y-chromosome in migrate lymphoid (lymph nodes, spleen, bone marrow) or in non-lymphoid organs (liver, heart, brain, skin) syngeneic recipients. In addition to the migration of cells from the bone marrow to other organs, there is a way back migration of cells from the circulation to the bone marrow. B16 melanoma stimulates the migration of transplanted MSCs and BMC in bone marrow. It is found that tumor growth enhanced migration of transplanted bone marrow cells, including populations of MSCs in the bone marrow. In the early stages of tumor formation MSC migration activity higher than the BMC. In the later stages of tumor formation undivided population of bone marrow cells migrate to the intense swelling compared with a population of MSCs. Conclusion. The possibility of using bone marrow MSCs for targeted therapy of tumor diseases, because migration of MSCs in tumor tissue can be used to effectively deliver anticancer drugs.

  5. Increased concentration of Pseudomonas aeruginosa and Staphylococcus sp. in small animals exposed to aerospace environments

    Science.gov (United States)

    Guthrie, R. K.

    1976-01-01

    The effects of increased concentrations of PSEUDOMONAS AERUGINOSA AND STAPHYLOCOCCUS in the total bacterial flora of small animals exposed to simulated spacecraft environments were evaluated. Tests to detect changes in infectivity, effects of antibiotic treatments, immune responses to bacterial antigens, and effectiveness of immune responses in the experimental environment were conducted. The most significant results appear to be the differences in immune responses at simulated altitudes and the production of infection in the presence of a specific antibody.

  6. Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

    Energy Technology Data Exchange (ETDEWEB)

    Joint Graduate Group in Bioengineering, University of California, San Francisco and University of California, Berkeley; Department of Radiology, University of California; Gullberg, Grant T; Hwang, Andrew B.; Franc, Benjamin L.; Gullberg, Grant T.; Hasegawa, Bruce H.

    2008-02-15

    Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the

  7. Dynamic studies of small animals with a four-color diffuse optical tomography imager

    International Nuclear Information System (INIS)

    Schmitz, Christoph H.; Graber, Harry L.; Pei Yaling; Farber, Mark; Stewart, Mark; Levina, Rita D.; Levin, Mikhail B.; Xu Yong; Barbour, Randall L.

    2005-01-01

    We present newly developed instrumentation for full-tomographic four-wavelength, continuous wave, diffuse optical tomography (DOT) imaging on small animals. A small-animal imaging stage was constructed, from materials compatible with in-magnet studies, which offers stereotaxic fixation of the animal and precise, stable probe positioning. Instrument performance, based on calibration and phantom studies, demonstrates excellent long-term signal stability. DOT measurements of the functional rat brain response to electric paw stimulation are presented, and these demonstrate high data quality and excellent sensitivity to hemodynamic changes. A general linear model analysis on individual trials is used to localize and quantify the occurrence of functional behavior associated with the different hemoglobin state responses. Statistical evaluation of outcomes of individual trials is employed to identify significant regional response variations for different stimulation sites. Image results reveal a diffuse cortical response and a strong reaction of the thalamus, both indicative of activation of pain pathways by the stimulation. In addition, a weaker lateralized functional component is observed in the brain response, suggesting presence of motor activation. An important outcome of the experiment is that it shows that reactions to individual provocations can be monitored, without having to resort to signal averaging. Thus the described technology may be useful for studies of long-term trends in hemodynamic response, as would occur, for example, in behavioral studies involving freely moving animals

  8. Near Field UHF RFID Antenna System Enabling the Tracking of Small Laboratory Animals

    Directory of Open Access Journals (Sweden)

    Luca Catarinucci

    2013-01-01

    Full Text Available Radio frequency identification (RFID technology is more and more adopted in a wide range of applicative scenarios. In many cases, such as the tracking of small-size living animals for behaviour analysis purposes, the straightforward use of commercial solutions does not ensure adequate performance. Consequently, both RFID hardware and the control software should be tailored for the particular application. In this work, a novel RFID-based approach enabling an effective localization and tracking of small-sized laboratory animals is proposed. It is mainly based on a UHF Near Field RFID multiantenna system, to be placed under the animals’ cage, and able to rigorously identify the NF RFID tags implanted in laboratory animals (e.g., mice. Once the requirements of the reader antenna have been individuated, the antenna system has been designed and realized. Moreover, an algorithm based on the measured Received Signal Strength Indication (RSSI aiming at removing potential ambiguities in data captured by the multiantenna system has been developed and integrated. The animal tracking system has been largely tested on phantom mice in order to verify its ability to precisely localize each subject and to reconstruct its path. The achieved and discussed results demonstrate the effectiveness of the proposed tracking system.

  9. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  10. Human multipotent mesenchymal stromal cells in the treatment of postoperative temporal bone defect: an animal model

    Czech Academy of Sciences Publication Activity Database

    Školoudík, L.; Chrobok, V.; Kalfert, D.; Kočí, Zuzana; Syková, Eva; Chumak, Tetyana; Popelář, Jiří; Syka, Josef; Laco, J.; Dědková, J.; Dayanithi, Govindan; Filip, S.

    2016-01-01

    Roč. 25, č. 7 (2016), s. 1405-1414 ISSN 0963-6897 R&D Projects: GA MŠk(CZ) LO1309 Institutional support: RVO:68378041 Keywords : Human bone marrow * Human mesenchymal stromal cells (hMSCs) * Middle ear surgery * Temporal bone Subject RIV: FP - Other Medical Disciplines Impact factor: 3.006, year: 2016

  11. Coil concepts for rapid and motion-compensated MR-Imaging of small animals

    International Nuclear Information System (INIS)

    Korn, Matthias

    2009-01-01

    In this work radiofrequency-coils for the imaging of small animals in clinical whole-body MRI-systems were developed. Therefore in a first step single-channel solenoids were designed and characterized. The solenoids had two and three windings respectively, which were implemented as double wires to increase the homogeneity of the receive profile. These coils allow the acquisition of whole-body images of mice with high signal-to-noise ratio and homogeneity over a distance of at least 6.3 cm. Since many imaging experiments require rapid image acquisition, in the next step a novel coil concept was developed, which, due to its geometry, enables parallel imaging in arbitrary directions. A prototype was assembled and tested on phantom and small-animal experiments. With an accelerating factor of R=2, the difference of the SNR in all directions from the theoretical maximum, was less than 1%. In order to compensate physiological motion by the self-gating technique, in this work a coil is presented for the first time, which selectively amplifies the self-gating signal, while - due to a optical detuning technique - preserving the homogeneous illumination of the image. In vivo experiments on a small animal show an amplification of the self-gating signal by at least 40%. (orig.)

  12. Open-Source Medical Devices (OSMD) Design of a Small Animal Radiotherapy System

    Science.gov (United States)

    Prajapati, S.; Mackie, T. R.; Jeraj, R.

    2014-03-01

    Open-Source Medical Devices (OSMD) was initiated with the goal of facilitating medical research by developing medical technologies including both hardware and software on an open-source platform. Our first project was to develop an integrated imaging and radiotherapy device for small animals that includes computed tomography (CT), positron emission tomography (PET) and radiation therapy (RT) modalities for which technical specifications were defined in the first OSMD conference held in Madison, Wisconsin, USA in December 2011. This paper specifically focuses on the development of a small animal RT (micro-RT) system by designing a binary micro multileaf collimator (bmMLC) and a small animal treatment planning system (SATPS) to enable intensity modulated RT (IMRT). Both hardware and software projects are currently under development and their current progresses are described. After the development, both bmMLC and TPS will be validated and commissioned for a micro-RT system. Both hardware design and software development will be open-sourced after completion.

  13. GATE simulation of a new design of pinhole SPECT system for small animal brain imaging

    International Nuclear Information System (INIS)

    Ozsahin, D. Uzun; Bläckberg, L.; Fakhri, G. El; Sabet, H.

    2017-01-01

    Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.

  14. Design of a multimodal fibers optic system for small animal optical imaging.

    Science.gov (United States)

    Spinelli, Antonello E; Pagliazzi, Marco; Boschi, Federico

    2015-02-01

    Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using fluorescence or bioluminescence modalities. In this work we presented a set of simulated results of a novel small animal optical imaging module based on a fibers optics matrix, coupled with a position sensitive detector, devoted to acquire bioluminescence and Cerenkov images. Simulations were performed using GEANT 4 code with the GAMOS architecture using the tissue optics plugin. Results showed that it is possible to image a 30 × 30 mm region of interest using a fiber optics array containing 100 optical fibers without compromising the quality of the reconstruction. The number of fibers necessary to cover an adequate portion of a small animal is thus quite modest. This design allows integrating the module with magnetic resonance (MR) in order to acquire optical and MR images at the same time. A detailed model of the mouse anatomy, obtained by segmentation of 3D MRI images, will improve the quality of optical 3D reconstruction. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  16. A 3D HIDAC-PET camera with sub-millimeter resolution for imaging small animals

    International Nuclear Information System (INIS)

    Jeavons, A.P.; Chandler, R.A.; Dettmar, C.A.R.

    1999-01-01

    A HIDAC-PET camera consisting essentially of 5 million 0.5 mm gas avalanching detectors has been constructed for small-animal imaging. The particular HIDAC advantage--a high 3D spatial resolution--has been improved to 0.95 mm fwhm and to 0.7 mm fwhm when reconstructing with 3D-OSEM methods incorporating resolution recovery. A depth-of-interaction resolution of 2.5 mm is implicit, due to the laminar construction. Scatter-corrected sensitivity, at 8.9 cps/kBq (i.e. 0.9%) from a central point source, or 7.2 cps/kBq (543 cps/kBq/cm 3 ) from a distributed (40 mm diameter, 60 mm long) source is now much higher than previous, and other, work. A field-of-view of 100 mm (adjustable to 200 mm) diameter by 210 mm axially permits whole-body imaging of small animals, containing typically 4MBqs of activity, at 40 kcps of which 16% are random coincidences, with a typical scatter fraction of 44%. Throughout the field-of-view there are no positional distortions and relative quantitation is uniform to ± 3.5%, but some variation of spatial resolution is found. The performance demonstrates that HIDAC technology is quite appropriate for small-animal PET cameras

  17. Human amniotic membrane, best healing accelerator, and the choice of bone induction for vestibuloplasty technique (an animal study

    Directory of Open Access Journals (Sweden)

    Ahad Khoshzaban

    2010-12-01

    Full Text Available Mohammad H Samandari1, Shahriar Adibi2, Ahad Khoshzaban3, Sara Aghazadeh5, Parviz Dihimi4, Siamak S Torbaghan6, Saeed H Keshel5, Zohreh Shahabi71Department of Oral and Maxillofacial Surgery, Dentistry Faculty, 2Dental Research of Torabinejad Research Centre, 3Iranian Tissue Bank Research and Preparation Centre, Imam Khomeini Hospital Complex, 4Department of Oral and Maxillofacial Pathology, Dentistry Faculty, Isfahan University of Medical Sciences, Isfahan, Iran; 5Stem Cells Preparation Unit, Eye Research Center, Farabi Hospital, 6Department of Pathology, Imam Khomeini Medical Centre, 7BMT Center, Shariati Hospital, Tehran University of Medical Sciences, Tehran, IranObjective: To investigate the effects of amniotic membrane (AM in bone induction and wound healing after vestibuloplasty surgery on animal samples while receptacle proteins such as growth factors were considered as accelerators for wound healing and bone induction after these operations.Material and methods: Ten adult dogs (5 females, 5 males; race, Iranian mixed; weight, 44 pounds were included, which underwent surgery for transplantation on mandible and maxillary. AM was used for promoting bone induction and healing.Results: The tissue samples were obtained after 2, 8, and 12 weeks for histology survey. No significant differences were observed between male and female or left and right jaws. AM decreased fibrinoleukocytic exudates and inflammation in the experimental group, had significant effects on bone formation, considerably improves wound healing, and gives rise to bone induction (P < 0.0001.Conclusions: Our study findings indicate that the AM is a suitable cover for different injuries and acellular AM has the potential for rapid improvement and bone induction. The AM contains collagen, laminin, and fibronectin, which provide an appropriate substrate for bone induction. This substrate promoted bone induction and might contribute to induction of the progenitor cells and/or stem

  18. Animator

    Science.gov (United States)

    Tech Directions, 2008

    2008-01-01

    Art and animation work is the most significant part of electronic game development, but is also found in television commercials, computer programs, the Internet, comic books, and in just about every visual media imaginable. It is the part of the project that makes an abstract design idea concrete and visible. Animators create the motion of life in…

  19. Geo-PET: A novel generic organ-pet for small animal organs and tissues

    Science.gov (United States)

    Sensoy, Levent

    Reconstructed tomographic image resolution of small animal PET imaging systems is improving with advances in radiation detector development. However the trend towards higher resolution systems has come with an increase in price and system complexity. Recent developments in the area of solid-state photomultiplication devices like silicon photomultiplier arrays (SPMA) are creating opportunities for new high performance tools for PET scanner design. Imaging of excised small animal organs and tissues has been used as part of post-mortem studies in order to gain detailed, high-resolution anatomical information on sacrificed animals. However, this kind of ex-vivo specimen imaging has largely been limited to ultra-high resolution muCT. The inherent limitations to PET resolution have, to date, excluded PET imaging from these ex-vivo imaging studies. In this work, we leverage the diminishing physical size of current generation SPMA designs to create a very small, simple, and high-resolution prototype detector system targeting ex-vivo tomographic imaging of small animal organs and tissues. We investigate sensitivity, spatial resolution, and the reconstructed image quality of a prototype small animal PET scanner designed specifically for imaging of excised murine tissue and organs. We aim to demonstrate that a cost-effective silicon photomultiplier (SiPM) array based design with thin crystals (2 mm) to minimize depth of interaction errors might be able to achieve sub-millimeter resolution. We hypothesize that the substantial decrease in sensitivity associated with the thin crystals can be compensated for with increased solid angle detection, longer acquisitions, higher activity and wider acceptance energy windows (due to minimal scatter from excised organs). The constructed system has a functional field of view (FoV) of 40 mm diameter, which is adequate for most small animal specimen studies. We perform both analytical (3D-FBP) and iterative (ML-EM) methods in order to

  20. Small body size and extreme cortical bone remodeling indicate phyletic dwarfism in Magyarosaurus dacus (Sauropoda: Titanosauria).

    Science.gov (United States)

    Stein, Koen; Csiki, Zoltan; Rogers, Kristina Curry; Weishampel, David B; Redelstorff, Ragna; Carballido, Jose L; Sander, P Martin

    2010-05-18

    Sauropods were the largest terrestrial tetrapods (>10(5) kg) in Earth's history and grew at rates that rival those of extant mammals. Magyarosaurus dacus, a titanosaurian sauropod from the Upper Cretaceous (Maastrichtian) of Romania, is known exclusively from small individuals (dwarfism (phyletic nanism) in dinosaurs, but a recent study suggested that the small Romanian titanosaurs actually represent juveniles of a larger-bodied taxon. Here we present strong histological evidence that M. dacus was indeed a dwarf (phyletic nanoid). Bone histological analysis of an ontogenetic series of Magyarosaurus limb bones indicates that even the smallest Magyarosaurus specimens exhibit a bone microstructure identical to fully mature or old individuals of other sauropod taxa. Comparison of histologies with large-bodied sauropods suggests that Magyarosaurus had an extremely reduced growth rate, but had retained high basal metabolic rates typical for sauropods. The uniquely decreased growth rate and diminutive body size in Magyarosaurus were adaptations to life on a Cretaceous island and show that sauropod dinosaurs were not exempt from general ecological principles limiting body size.

  1. Do Bone Graft and Cracking of the Sclerotic Cavity Improve Fixation of Titanium and Hydroxyapatite-coated Revision Implants in an Animal Model?

    Science.gov (United States)

    Elmengaard, Brian; Baas, Joergen; Jakobsen, Thomas; Kold, Soren; Jensen, Thomas B; Bechtold, Joan E; Soballe, Kjeld

    2017-02-01

    We previously introduced a manual surgical technique that makes small perforations (cracks) through the sclerotic bone shell that typically forms during the process of aseptic loosening ("crack" revision technique). Perforating just the shell (without violating the proximal cortex) can maintain overall bone continuity while allowing marrow and vascular elements to access the implant surface. Because many revisions require bone graft to fill defects, we wanted to determine if bone graft could further increase implant fixation beyond what we have experimentally shown with the crack technique alone. Also, because both titanium (Ti6Al4V) and hydroxyapatite (HA) implant surfaces are used in revisions, we also wanted to determine their relative effectiveness in this model. We hypothesized that both (1) allografted plasma-sprayed Ti6Al4V; and (2) allografted plasma-sprayed HA-coated implants inserted with a crack revision technique have better fixation compared with a noncrack revision technique in each case. Under approval from our Institutional Animal Care and Use Committee, a female canine animal model was used to evaluate the uncemented revision technique (crack, noncrack) using paired contralateral implants while implant surface (Ti6Al4V, HA) was qualitatively compared between the two (unpaired) series. All groups received bone allograft tightly packed around the implant. This revision model includes a cylindrical implant pistoning 500 μm in a 0.75-mm gap, with polyethylene particles, for 8 weeks. This engenders a bone and tissue response representative of the metaphyseal cancellous region of an aseptically loosened component. At 8 weeks, the original implants were revised and followed for an additional 4 weeks. Mechanical fixation was assessed by load, stiffness, and energy to failure when loaded in axial pushout. Histomorphometry was used to determine the amount and location of bone and fibrous tissue in the grafted gap. The grafted crack revision improved

  2. Filtering and deconvolution for bioluminescence imaging of small animals; Filtrage et deconvolution en imagerie de bioluminescence chez le petit animal

    Energy Technology Data Exchange (ETDEWEB)

    Akkoul, S.

    2010-06-22

    This thesis is devoted to analysis of bioluminescence images applied to the small animal. This kind of imaging modality is used in cancerology studies. Nevertheless, some problems are related to the diffusion and the absorption of the tissues of the light of internal bioluminescent sources. In addition, system noise and the cosmic rays noise are present. This influences the quality of the images and makes it difficult to analyze. The purpose of this thesis is to overcome these disturbing effects. We first have proposed an image formation model for the bioluminescence images. The processing chain is constituted by a filtering stage followed by a deconvolution stage. We have proposed a new median filter to suppress the random value impulsive noise which corrupts the acquired images; this filter represents the first block of the proposed chain. For the deconvolution stage, we have performed a comparative study of various deconvolution algorithms. It allowed us to choose a blind deconvolution algorithm initialized with the estimated point spread function of the acquisition system. At first, we have validated our global approach by comparing our obtained results with the ground truth. Through various clinical tests, we have shown that the processing chain allows a significant improvement of the spatial resolution and a better distinction of very close tumor sources, what represents considerable contribution for the users of bioluminescence images. (author)

  3. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  4. Acceleration of vascularized bone tissue-engineered constructs in a large animal model combining intrinsic and extrinsic vascularization.

    Science.gov (United States)

    Weigand, Annika; Beier, Justus P; Hess, Andreas; Gerber, Thomas; Arkudas, Andreas; Horch, Raymund E; Boos, Anja M

    2015-05-01

    During the last decades, a range of excellent and promising strategies in Bone Tissue Engineering have been developed. However, the remaining major problem is the lack of vascularization. In this study, extrinsic and intrinsic vascularization strategies were combined for acceleration of vascularization. For optimal biomechanical stability of the defect site and simplifying future transition into clinical application, a primary stable and approved nanostructured bone substitute in clinically relevant size was used. An arteriovenous (AV) loop was microsurgically created in sheep and implanted, together with the bone substitute, in either perforated titanium chambers (intrinsic/extrinsic) for different time intervals of up to 18 weeks or isolated Teflon(®) chambers (intrinsic) for 18 weeks. Over time, magnetic resonance imaging and micro-computed tomography (CT) analyses illustrate the dense vascularization arising from the AV loop. The bone substitute was completely interspersed with newly formed tissue after 12 weeks of intrinsic/extrinsic vascularization and after 18 weeks of intrinsic/extrinsic and intrinsic vascularization. Successful matrix change from an inorganic to an organic scaffold could be demonstrated in vascularized areas with scanning electron microscopy and energy dispersive X-ray spectroscopy. Using the intrinsic vascularization method only, the degradation of the scaffold and osteoclastic activity was significantly lower after 18 weeks, compared with 12 and 18 weeks in the combined intrinsic-extrinsic model. Immunohistochemical staining revealed an increase in bone tissue formation over time, without a difference between intrinsic/extrinsic and intrinsic vascularization after 18 weeks. This study presents the combination of extrinsic and intrinsic vascularization strategies for the generation of an axially vascularized bone substitute in clinically relevant size using a large animal model. The additional extrinsic vascularization promotes tissue

  5. An in vivo technique for the measurement of bone blood flow in animals

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; DeLuca, P.M. Jr.; Pearson, D.W.; Nickles, R.J.; Lehner, C.E.; Lanphier, E.H.

    1987-01-01

    A new technique to measure the in vivo clearance of 41 Ar from the bone mineral matrix is demonstrated following fast neutron production of 41 Ar in bone via the 44 Ca(n,α) reaction at 14.1 MeV. At the end of irradiation, the 41 Ar activity is assayed with a Ge(Li) detector where sequential gamma-ray spectra are taken. Following full-energy peak integration, background and dead time correction, the activity of 41 Ar as a function of time is determined. Results indicated that the Ar washout from bone in rats using this technique was approximately 16 ml (100 ml min) -1 and in agreement with other measurement techniques. For sheep the bone perfusion in the tibia was approximately 1.9+-0.2 ml (100 ml min) -1 . (author)

  6. Prototype design of singles processing unit for the small animal PET

    Science.gov (United States)

    Deng, P.; Zhao, L.; Lu, J.; Li, B.; Dong, R.; Liu, S.; An, Q.

    2018-05-01

    Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly used for studying the animal model of disease, new drugs and new therapies. A prototype of Singles Processing Unit (SPU) for a small animal PET system was designed to obtain the time, energy, and position information. The energy and position is actually calculated through high precison charge measurement, which is based on amplification, shaping, A/D conversion and area calculation in digital signal processing domian. Analysis and simulations were also conducted to optimize the key parameters in system design. Initial tests indicate that the charge and time precision is better than 3‰ FWHM and 350 ps FWHM respectively, while the position resolution is better than 3.5‰ FWHM. Commination tests of the SPU prototype with the PET detector indicate that the system time precision is better than 2.5 ns, while the flood map and energy spectra concored well with the expected.

  7. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  8. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  9. Anaphylaxis Imaging: Non-Invasive Measurement of Surface Body Temperature and Physical Activity in Small Animals.

    Directory of Open Access Journals (Sweden)

    Krisztina Manzano-Szalai

    Full Text Available In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i milk allergy, ii peanut allergy and iii egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour.

  10. Design of small-animal thermal neutron irradiation facility at the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Liu, H.B.

    1996-01-01

    The broad beam facility (BBF) at the Brookhaven Medical Research Reactor (BMRR) can provide a thermal neutron beam with flux intensity and quality comparable to the beam currently used for research on neutron capture therapy using cell-culture and small-animal irradiations. Monte Carlo computations were made, first, to compare with the dosimetric measurements at the existing BBF and, second, to calculate the neutron and gamma fluxes and doses expected at the proposed BBF. Multiple cell cultures or small animals could be irradiated simultaneously at the so-modified BBF under conditions similar to or better than those individual animals irradiated at the existing thermal neutron irradiation Facility (TNIF) of the BMRR. The flux intensity of the collimated thermal neutron beam at the proposed BBF would be 1.7 x 10 10 n/cm 2 ·s at 3-MW reactor power, the same as at the TNIF. However, the proposed collimated beam would have much lower gamma (0.89 x 10 -11 cGy·cm 2 /n th ) and fast neutron (0.58 x 10 -11 cGy·cm 2 /n th ) contaminations, 64 and 19% of those at the TNIF, respectively. The feasibility of remodeling the facility is discussed

  11. Subchondral Bone Plate Thickening Precedes Chondrocyte Apoptosis and Cartilage Degradation in Spontaneous Animal Models of Osteoarthritis

    OpenAIRE

    Zamli, Zaitunnatakhin; Robson Brown, Kate; Tarlton, John F.; Adams, Mike A.; Torlot, Georgina E.; Cartwright, Charlie; Cook, William A.; Vassilevskaja, Kristiina; Sharif, Mohammed

    2014-01-01

    Osteoarthritis (OA) is the most common joint disorder characterised by bone remodelling and cartilage degradation and associated with chondrocyte apoptosis. These processes were investigated at 10, 16, 24, and 30 weeks in Dunkin Hartley (DH) and Bristol Strain 2 (BS2) guinea pigs that develop OA spontaneously. Both strains had a more pronounced chondrocyte apoptosis, cartilage degradation, and subchondral bone changes in the medial than the lateral side of the tibia, and between strains, the ...

  12. Heterogeneous Stock Rat: A Unique Animal Model for Mapping Genes Influencing Bone Fragility

    OpenAIRE

    Alam, Imranul; Koller, Daniel L.; Sun, Qiwei; Roeder, Ryan K.; Cañete, Toni; Blázquez, Gloria; López-Aumatell, Regina; Martínez-Membrives, Esther; Vicens-Costa, Elia; Mont, Carme; Díaz, Sira; Tobeña, Adolf; Fernández-Teruel, Alberto; Whitley, Adam; Strid, Pernilla

    2011-01-01

    Previously, we demonstrated that skeletal mass, structure and biomechanical properties vary considerably among 11 different inbred rat strains. Subsequently, we performed quantitative trait loci (QTL) analysis in 4 inbred rat strains (F344, LEW, COP and DA) for different bone phenotypes and identified several candidate genes influencing various bone traits. The standard approach to narrowing QTL intervals down to a few candidate genes typically employs the generation of congenic lines, which ...

  13. Scaffold-cell bone engineering in a validated preclinical animal model: precursors vs differentiated cell source.

    Science.gov (United States)

    Berner, A; Henkel, J; Woodruff, M A; Saifzadeh, S; Kirby, G; Zaiss, S; Gohlke, J; Reichert, J C; Nerlich, M; Schuetz, M A; Hutmacher, D W

    2017-07-01

    The properties of osteoblasts (OBs) isolated from the axial skeleton (tOBs) differ from OBs of the orofacial skeleton (mOBs) due to the different embryological origins of the bones. The aim of the study was to assess and compare the regenerative potential of allogenic bone marrow-derived mesenchymal progenitor cells with allogenic tOBs and allogenic mOBs in combination with a mPCL-TCP scaffold in critical-sized segmental bone defects in sheep tibiae. After 6 months, the tibiae were explanted and underwent biomechanical testing, micro-computed tomography (microCT) and histological and immunohistochemical analyses. Allogenic MPCs demonstrated a trend towards a better outcome in biomechanical testing and the mean values of newly formed bone. Biomechanical, microCT and histological analysis showed no significant differences in the bone regeneration potential of tOBs and mOBs in our in vitro study, as well as in the bone regeneration potential of different cell types in vivo. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Radiosteoplasty study in animal bone and radiodosimetric evaluation using Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcia Flavia; Campos, Tarcisio Passos Ribeiro [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear]. E-mail: marciaflaviafisio@gmail.com; campos@nuclear.ufmg.br

    2007-07-01

    The radiosteoplasty is a procedure that consists of the injection of a radioactive biomaterial incorporated to the bone cement into the osseous structure affected by cancer. This technique has been developed with the major objective to control the tumor or the regional bone metastasis (in situ) besides pain reduction and structural resistance increasing. In the present study the radiosteoplasty is applied to the bovine and swine bones in vitro using non-radioactive cement. The objective is to know the spatial distribution of the cold compound (non radioactive) in pig and ox bones after implant. A 2 mm needle was introduced into the cortical bone previously perforated. The distribution of this biomaterial was observed trough radiological images obtained just after the compound application. Recent dosimetric studies using Monte Carlo N-Particle method (MCNP-5) concluded that the spatial dose distribution is suitable for the protocol namely radiosteoplasty applied to treat bone tumors on superior and inferior members. The Monte Carlo method simulates the present process and it is particularly interesting tool to solve the complex photon and electron particle transport problems that can not be modeled by codes based on deterministic methods. These related radiodosimetric studies are presented and discussed. (author)

  15. Pain control in small animalsControle da dor em pequenos animais

    Directory of Open Access Journals (Sweden)

    Julia Duarte Penter

    2011-12-01

    Full Text Available Pain is an unpleasant sensory or emotional experience that follows the application of a noxious stimulus. Can be experienced with or without the concomitant occurrence of physical stress signs, which occurs frequently in animals caused by trauma, systemic disease or surgical procedures. The control depends on length, where there are painful impulses and mental status of the animal. It is an important clinical condition, resulting in suffer that will affect quality life. This paper is a review of pathophysiology and pain control in small animals.A dor é uma experiência sensorial ou emocional desagradável que se segue à aplicação de um estímulo nocivo. Pode ser vivenciada com ou sem o acontecimento concomitante de sinais físicos de estresse, trauma, doença sistêmica ou procedimento cirúrgico. Seu controle depende de sua duração, de onde surgem os impulsos dolorosos e do estado de consciência do animal. É uma condição clinicamente importante, que resulta em sofrimento e afeta a qualidade de vida dos animais. O objetivo deste trabalho é a revisão da fisiopatologia e controle da dor em pequenos animais.

  16. An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb.

    Science.gov (United States)

    Farrell, Brad J; Prilutsky, Boris I; Kistenberg, Robert S; Dalton, John F; Pitkin, Mark

    2014-03-01

    Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking. Full-body mechanics of walking in two cats were recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading on the implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study. The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth. The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a bone-anchored prosthesis. Future studies with this model will help optimize the implant and prosthesis properties. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Development of a New Positron Emission Tomography Tracer for Targeting Tumor Angiogenesis: Synthesis, Small Animal Imaging, and Radiation Dosimetry

    Directory of Open Access Journals (Sweden)

    David S. Lalush

    2013-05-01

    Full Text Available Angiogenesis plays a key role in cancer progression and correlates with disease aggressiveness and poor clinical outcomes. Affinity ligands discovered by screening phage display random peptide libraries can be engineered to molecularly target tumor blood vessels for noninvasive imaging and early detection of tumor aggressiveness. In this study, we tested the ability of a phage-display-selected peptide sequence recognizing specifically bone marrow- derived pro-angiogenic tumor-homing cells, the QFP-peptide, radiolabeled with 64Cu radioisotope to selectively image tumor vasculature in vivo by positron emission tomography (PET. To prepare the targeted PET tracer we modified QFP-phage with the DOTA chelator and radiolabeled the purified QFP-phage-DOTA intermediate with 64Cu to obtain QFP-targeted radioconjugate with high radiopharmaceutical yield and specific activity. We evaluated the new PET tracer in vivo in a subcutaneous (s.c. Lewis lung carcinoma (LLC mouse model and conducted tissue distribution, small animal PET/CT imaging study, autoradiography, histology, fluorescence imaging, and dosimetry assessments. The results from this study show that, in the context of the s.c. LLC immunocompetent mouse model, the QFP-tracer can target tumor blood vessels selectively. However, further optimization of the biodistribution and dosimetry profile of the tracer is necessary to ensure efficient radiopharmaceutical applications enabled by the biological specificity of the QFP-peptide.

  18. The effects of cutting parameters on cutting forces and heat generation when drilling animal bone and biomechanical test materials.

    Science.gov (United States)

    Cseke, Akos; Heinemann, Robert

    2018-01-01

    The research presented in this paper investigated the effects of spindle speed and feed rate on the resultant cutting forces (thrust force and torque) and temperatures while drilling SawBones ® biomechanical test materials and cadaveric cortical bone (bovine and porcine femur) specimens. It also investigated cortical bone anisotropy on the cutting forces, when drilling in axial and radial directions. The cutting forces are only affected by the feed rate, whereas the cutting temperature in contrast is affected by both spindle speed and feed rate. The temperature distribution indicates friction as the primary heat source, which is caused by the rubbing of the tool margins and the already cut chips over the borehole wall. Cutting forces were considerably higher when drilling animal cortical bone, in comparison to cortical test material. Drilling direction, and therewith anisotropy, appears to have a negligible effect on the cutting forces. The results suggest that this can be attributed to the osteons being cut at an angle rather than in purely axial or radial direction, as a result of a twist drill's point angle. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Use of aspiration method for collecting brain samples for rabies diagnosis in small wild animals.

    Science.gov (United States)

    Iamamoto, K; Quadros, J; Queiroz, L H

    2011-02-01

    In developing countries such as Brazil, where canine rabies is still a considerable problem, samples from wildlife species are infrequently collected and submitted for screening for rabies. A collaborative study was established involving environmental biologists and veterinarians for rabies epidemiological research in a specific ecological area located at the Sao Paulo State, Brazil. The wild animals' brains are required to be collected without skull damage because the skull's measurements are important in the identification of the captured animal species. For this purpose, samples from bats and small mammals were collected using an aspiration method by inserting a plastic pipette into the brain through the magnum foramen. While there is a progressive increase in the use of the plastic pipette technique in various studies undertaken, it is also appreciated that this method could foster collaborative research between wildlife scientists and rabies epidemiologists thus improving rabies surveillance. © 2009 Blackwell Verlag GmbH.

  20. In Vivo Respiratory-Gated Micro-CT Imaging in Small-Animal Oncology Models

    Directory of Open Access Journals (Sweden)

    Dawn Cavanaugh

    2004-01-01

    Full Text Available Micro-computed tomography (micro-CT is becoming an accepted research tool for the noninvasive examination of laboratory animals such as mice and rats, but to date, in vivo scanning has largely been limited to the evaluation of skeletal tissues. We use a commercially available micro-CT device to perform respiratory gated in vivo acquisitions suitable for thoracic imaging. The instrument is described, along with the scan protocol and animal preparation techniques. Preliminary results confirm that lung tumors as small as 1 mm in diameter are visible in vivo with these methods. Radiation dose was evaluated using several approaches, and was found to be approximately 0.15 Gy for this respiratory-gated micro-CT imaging protocol. The combination of high-resolution CT imaging and respiratory-gated acquisitions appears well-suited to serial in vivo scanning.

  1. [The small pox vaccine: its first century in Brazil (from the Jennerian to the animal vaccine)].

    Science.gov (United States)

    Fernandes, T

    1999-01-01

    Covering a period of roughly hundred years, the article looks at some of the more meaningful events during the period in which the small pox vaccine was institutionalized in Brazil. Discoveries and discussions then taking place in other countries are also examined, particularly as they influenced Brazil. The process is followed from introduction of the human vaccine to the arrival of the animal vaccine and creation of the Municipal Vaccine Institute--a private initative by physician Pedro Affonso Franco, also known as the barao de Pedro Affonso. Adoption of the animal vaccine not only represented progress in controlling the disease but also spurred discussions that saw medical and political groups in Brazil taking sides with either Oswaldo Cruz or the barao de Pedro Affonso. The debate continued within the academic and political arenas until the Vaccine Institute was made part of the Manguinhos laboratories.

  2. RFID Technology for Continuous Monitoring of Physiological Signals in Small Animals.

    Science.gov (United States)

    Volk, Tobias; Gorbey, Stefan; Bhattacharyya, Mayukh; Gruenwald, Waldemar; Lemmer, Björn; Reindl, Leonhard M; Stieglitz, Thomas; Jansen, Dirk

    2015-02-01

    Telemetry systems enable researchers to continuously monitor physiological signals in unrestrained, freely moving small rodents. Drawbacks of common systems are limited operation time, the need to house the animals separately, and the necessity of a stable communication link. Furthermore, the costs of the typically proprietary telemetry systems reduce the acceptance. The aim of this paper is to introduce a low-cost telemetry system based on common radio frequency identification technology optimized for battery-independent operational time, good reusability, and flexibility. The presented implant is equipped with sensors to measure electrocardiogram, arterial blood pressure, and body temperature. The biological signals are transmitted as digital data streams. The device is able of monitoring several freely moving animals housed in groups with a single reader station. The modular concept of the system significantly reduces the costs to monitor multiple physiological functions and refining procedures in preclinical research.

  3. Incorporation of osteogenic and angiogenic small interfering RNAs into chitosan sponge for bone tissue engineering

    Directory of Open Access Journals (Sweden)

    Jia S

    2014-11-01

    Full Text Available Sen Jia,1,* Xinjie Yang,1,* Wen Song,2,* Lei Wang,1 Kaixiu Fang,3 Zhiqiang Hu,1,4 Zihui Yang,1 Chun Shan,1 Delin Lei,1 Bin Lu1 1Department of Oral and Maxillofacial Surgery, 2Department of Prosthetic Dentistry, 3Department of Implant Dentistry, School of Stomatology, State Key Laboratory of Military Stomatology, Fourth Military Medical University, Xi’an People’s Republic of China; 4Department of Otorhinolaryngology, No 113 Hospital of People’s Liberation Army, Ningbo, People’s Republic of China *These authors contributed to this paper equally and are considered to be joint first authors Abstract: Engineered bone substitutes are being extensively explored in response to growing demand. However, the angiogenesis that occurs during bone formation is often overlooked in scaffold design. In this novel study, we incorporated two small interfering RNAs (siRNAs, ie, small interfering RNA targets casein kinase 2 interaction protein 1 (siCkip-1 and small interfering RNA targets soluble VEGF receptor 1 (siFlt-1, which can promote osteogenesis and angiogenesis, into a chitosan sponge. This scaffold could maintain siRNAs for over 2 weeks in neutral phosphate-buffered saline and degraded rapidly in the presence of lysozyme. The chitosan sponge with siCkip-1 and siFlt-1 in vitro bioactivity was investigated using mesenchymal stem cells. Target genes were significantly suppressed, and osteocalcin, alkaline phosphatase, and vascular endothelial growth factor were significantly upregulated. Alizarin Red staining revealed that mineralization of the extracellular matrix was markedly enhanced by dual transfection. Further analysis by immunofluorescence confirmed that the siRNA-modified scaffold simultaneously improved the expression of osteocalcin and von Willebrand factor. In vivo testing in a skull critical-size defect model showed marked bone regeneration in rats treated with siCkip-1 and siFlt-1. In conclusion, chitosan sponge containing osteogenic and

  4. Biological X-ray irradiator characterization for use with small animals and cells.

    Science.gov (United States)

    Bruno, A Colello; Mazaro, S J; Amaral, L L; Rego, E M; Oliveira, H F; Pavoni, J F

    2017-03-02

    This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.

  5. Fully automated intrinsic respiratory and cardiac gating for small animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, J; Baeuerle, T; Semmler, W; Bartling, S H [Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg (Germany); Dinkel, J [Department of Radiology, German Cancer Research Center, Heidelberg (Germany); Zwick, S [Department of Diagnostic Radiology, Medical Physics, Freiburg University (Germany); Grasruck, M [Siemens Healthcare, Forchheim (Germany); Kiessling, F [Chair of Experimental Molecular Imaging, RWTH-Aachen University, Medical Faculty, Aachen (Germany); Gupta, R [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)], E-mail: j.kuntz@dkfz.de

    2010-04-07

    A fully automated, intrinsic gating algorithm for small animal cone-beam CT is described and evaluated. A parameter representing the organ motion, derived from the raw projection images, is used for both cardiac and respiratory gating. The proposed algorithm makes it possible to reconstruct motion-corrected still images as well as to generate four-dimensional (4D) datasets representing the cardiac and pulmonary anatomy of free-breathing animals without the use of electrocardiogram (ECG) or respiratory sensors. Variation analysis of projections from several rotations is used to place a region of interest (ROI) on the diaphragm. The ROI is cranially extended to include the heart. The centre of mass (COM) variation within this ROI, the filtered frequency response and the local maxima are used to derive a binary motion-gating parameter for phase-sensitive gated reconstruction. This algorithm was implemented on a flat-panel-based cone-beam CT scanner and evaluated using a moving phantom and animal scans (seven rats and eight mice). Volumes were determined using a semiautomatic segmentation. In all cases robust gating signals could be obtained. The maximum volume error in phantom studies was less than 6%. By utilizing extrinsic gating via externally placed cardiac and respiratory sensors, the functional parameters (e.g. cardiac ejection fraction) and image quality were equivalent to this current gold standard. This algorithm obviates the necessity of both gating hardware and user interaction. The simplicity of the proposed algorithm enables adoption in a wide range of small animal cone-beam CT scanners.

  6. Biological X-ray irradiator characterization for use with small animals and cells

    Directory of Open Access Journals (Sweden)

    A. Colello Bruno

    Full Text Available This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current, the radiometric survey (leakage radiation and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1 and remained stable for long (constant and short (repeatability intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer. The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators for cells and small animal irradiation, especially in early research stages.

  7. Techniques for small-bone lengthening in congenital anomalies of the hand and foot.

    Science.gov (United States)

    Minguella, J; Cabrera, M; Escolá, J

    2001-10-01

    The purpose of this study is to analyse three different lengthening techniques used in 31 small bones for congenital malformations of the hand and foot: 15 metacarpals, 12 metatarsals, 1 foot stump and 3 spaces between a previously transplanted phalanx end of the carpus or the metacarpal. Progressive lengthening with an external fixator device was performed in 23 cases: the callus distraction (callotasis) technique was used in 15 cases, whereas in the other 8 cases the speed of lengthening was faster and the defect bridged with a bone graft as a second stage. In another eight cases, a one-stage lengthening was performed. In the callotasis group, the total length gained ranged from 9 mm to 30 mm and the percentage of lengthening obtained (compared with the initial bone length) averaged 53.4%; in the fast lengthening group, the length gained ranged from 8 mm to 15 mm, and the average percentage of lengthening was 53.1%; and in the one-stage group, the length gained ranged from 7 mm to 15 mm, and the average percentage of lengthening was 43%. The overall complication rate was 22.5%.

  8. Small-animal dark-field radiography for pulmonary emphysema evaluation

    Science.gov (United States)

    Yaroshenko, Andre; Meinel, Felix G.; Hellbach, Katharina; Bech, Martin; Velroyen, Astrid; Müller, Mark; Bamberg, Fabian; Nikolaou, Konstantin; Reiser, Maximilian F.; Yildirim, Ali Ã.-.; Eickelberg, Oliver; Pfeiffer, Franz

    2014-03-01

    Chronic obstructive pulmonary disease (COPD) is one of the leading causes of morbidity and mortality worldwide and emphysema is one of its main components. The disorder is characterized by irreversible destruction of the alveolar walls and enlargement of distal airspaces. Despite the severe changes in the lung tissue morphology, conventional chest radiographs have only a limited sensitivity for the detection of mild to moderate emphysema. X-ray dark-field is an imaging modality that can significantly increase the visibility of lung tissue on radiographic images. The dark-field signal is generated by coherent, small-angle scattering of x-rays on the air-tissue interfaces in the lung. Therefore, morphological changes in the lung can be clearly visualized on dark-field images. This is demonstrated by a preclinical study with a small-animal emphysema model. To generate a murine model of pulmonary emphysema, a female C57BL/6N mouse was treated with a single orotracheal application of porcine pancreatic elastase (80 U/kg body weight) dissolved in phosphate-buffered saline (PBS). Control mouse received PBS. The mice were imaged using a small-animal dark-field scanner. While conventional x-ray transmission radiography images revealed only subtle indirect signs of the pulmonary disorder, the difference between healthy and emphysematous lungs could be clearly directly visualized on the dark-field images. The dose applied to the animals is compatible with longitudinal studies. The imaging results correlate well with histology. The results of this study reveal the high potential of dark-field radiography for clinical lung imaging.

  9. Position-Sensitive Detector with Depth-of-Interaction Determination for Small Animal PET

    CERN Document Server

    Fedorov, A; Kholmetsky, A L; Korzhik, M V; Lecoq, P; Lobko, A S; Missevitch, O V; Tkatchev, A

    2002-01-01

    Crystal arrays made of LSO and LuAP crystals 2x2x10 mm pixels were manufactured for evaluation of detector with depth-of-interaction (DOI) determination capability intended for small animal positron emission tomograph. Position-sensitive LSO/LuAP phoswich DOI detector based on crystal 8x8 arrays and HAMAMATSU R5900-00-M64 position-sensitive multi-anode photomultiplier tube was developed and evaluated. Time resolution was found to be not worse than 1.0 ns FWHM for both layers, and spatial resolution mean value was 1.5 mm FWHM for the center of field-of-view.

  10. New design of a quasi-monolithic detector module with DOI capability for small animal pet

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Lee, Seung-Jae; Baek, Cheol-Ha; Choi, Yong

    2008-01-01

    We report a new design of a detector module with depth of interaction (DOI) based on a quasi-monolithic LSO crystal, a multi-channel sensor, and maximum-likelihood position-estimation (MLPE) algorithm. Light transport and detection were modeled in a quasi-monolithic crystal using DETECT2000 code, with lookup tables (LUTs) built by simulation. Events were well separated by applying the MLPE method within 2.0 mm spatial resolution in both trans-axial and DOI directions. These results demonstrate that the proposed detector provides dependable positioning capability for small animal positron emission tomography (PET)

  11. Energy resolution of a four-layer depth of interaction detector block for small animal PET

    International Nuclear Information System (INIS)

    Tsuda, Tomoaki; Kawai, Hideyuki; Orita, Narimichi; Murayama, Hideo; Yoshida, Eiji; Inadama, Naoko; Yamaya, Taiga; Omura, Tomohide

    2004-01-01

    We are now planning to develop a positron emission tomograph dedicated to small animals such as rats and mice which meets the demand for higher sensitivity. We proposed a new depth of interaction (DOI) detector arrangement to obtain DOI information by using a four-layer detector with all the same crystal elements. In this DOI detector, we control the behavior of scintillation photons by inserting the reflectors between crystal elements so that the DOI information of four layers can be extracted from one two-dimensional (2D) position histogram made by Anger-type calculation. In this work, we evaluate the energy resolution of this four-layer DOI detector. (author)

  12. Plutonium and other alpha-emitters in bones of wild, herbivorous animals from north-eastern Poland

    Energy Technology Data Exchange (ETDEWEB)

    Mietelski, J.W. E-mail: mietelsk@alf.ifj.edu.pl; Gaca, P.; Jasinska, M

    2000-07-15

    The results of the investigation of {sup 239+240}Pu, {sup 241}Am and thorium isotope activity concentrations in bones of wild herbivorous animals (deer, roe-deer, boars, elks) from north-eastern Poland are presented. The area on which the animals were living had relatively high Chernobyl plutonium fallout. Possible traces of plutonium were seen only in four samples, but only for one it was it 3{sigma} above background, at 6.2 {+-} 2.4 mBq/kg (ash). The {sup 241}Am activity concentration was below the detection limits in all samples. The maximum {sup 228}Th concentration in the samples was 7.81 {+-} 0.44 Bq/kg (ash), calculated under the assumption of 100% thorium recovery. This isotope seems to originate in bones not from direct incorporation but from the decay of {sup 228}Ra. Large variations in activity concentration was observed, as well as some differences between boars and the chewing animals.

  13. Absolute quantitative total-body small-animal SPECT with focusing pinholes

    International Nuclear Information System (INIS)

    Wu, Chao; Have, Frans van der; Vastenhouw, Brendan; Beekman, Freek J.; Dierckx, Rudi A.J.O.; Paans, Anne M.J.

    2010-01-01

    In pinhole SPECT, attenuation of the photon flux on trajectories between source and pinholes affects quantitative accuracy of reconstructed images. Previously we introduced iterative methods that compensate for image degrading effects of detector and pinhole blurring, pinhole sensitivity and scatter for multi-pinhole SPECT. The aim of this paper is (1) to investigate the accuracy of the Chang algorithm in rodents and (2) to present a practical Chang-based method using body outline contours obtained with optical cameras. Here we develop and experimentally validate a practical method for attenuation correction based on a Chang first-order method. This approach has the advantage that it is employed after, and therefore independently from, iterative reconstruction. Therefore, no new system matrix has to be calculated for each specific animal. Experiments with phantoms and animals were performed with a high-resolution focusing multi-pinhole SPECT system (U-SPECT-II, MILabs, The Netherlands). This SPECT system provides three additional optical camera images of the animal for each SPECT scan from which the animal contour can be estimated. Phantom experiments demonstrated that an average quantification error of -18.7% was reduced to -1.7% when both window-based scatter correction and Chang correction based on the body outline from optical images were applied. Without scatter and attenuation correction, quantification errors in a sacrificed rat containing sources with known activity ranged from -23.6 to -9.3%. These errors were reduced to values between -6.3 and +4.3% (with an average magnitude of 2.1%) after applying scatter and Chang attenuation correction. We conclude that the modified Chang correction based on body contour combined with window-based scatter correction is a practical method for obtaining small-animal SPECT images with high quantitative accuracy. (orig.)

  14. The use of lyophilised bovine bone xenograft in mandibular reconstructive surgery - an animal experimental surgery

    International Nuclear Information System (INIS)

    Samsudin, A.R.; Meor Kamal, M. Z.; Afifi Abu Bakar

    1999-01-01

    The aim of this study is to look at the effectiveness of using lyophillised bovine bone xenograft in mandibular reconstructive surgery. Six adult merino sheep underwent bilateral marginal block resection of the mandible under general anaesthesia. The defect on the right body of mandible was left alone while the similar mandibulectomy defect on the left body of mandible was reconstructed using a cortico-cancellous block of radiosterilised lyophillised bovine bone xenograft which was procured from a calve femur. The bone xenograft was fixed and immobilized using titanium mini plates and screws. All the sheep returned to the controlled grazing ground on the 7th. Postoperative day. One sheep was sacrificed every month and the mandible was retrieved for postmortem gross and microscopical histological examination. Clinical results showed no evidence of tissue rejection in the mandible of the sheep and all the wounds healed well. All sheep showed no problem with normal eating habits. Histological examination showed resorption of the xenograft very early at one month postoperative and xenograft resorption together with new host bone deposition started at 2 months postoperative and maximise at 6 months postoperative. There is also evidence showing that the cancellous portion resorp more than the cortical portion of the xenograft. In conclusion, cortico-cancellous blocks of bovine bone xenograft may be use in mandibular reconstructive surgery giving esthetically acceptable, functional, biocompatible and overall clinically predictable results

  15. The Nerve Supply of the Bone Marrow in Different Laboratory Animals

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, W. [Forschungsgruppe Freiburg, Institut fuer Haematologie der Gesellschaft fuer Strahlenforschung Assoziation mit EURATOM, Freiburg/Breisgau, Federal Republic of Germany (Germany)

    1967-07-15

    The proliferation and release of the different types of cells from the bone marrow presents so many obscurities in the explanation of the maintenance of homeostasis at the level of the blood corpuscles that one wonders if this difficulty is due to a lack of information in some important area. The function of an organ, and the influence that other organs may have on its physiological and pathological changes, cannot be understood if the role of the nervous system and the hormones are not taken into consideration; but when we study the bone marrow and speak about its function as a blood-forming organ, the nervous system is continually ignored. The situation is such that the first question that comes to mind is this: Are there nerves in the bone marrow? The answer of the old anatomists was: Yes. The description of nerves entering into the bone cavity can be found in papers published more than one hundred years ago, but the description of their distribution and relation with the different elements of the marrow is vague and contradictory. Consequently we considered it worthwhile to study the problem of the innervation of the bone marrow anew.

  16. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    Science.gov (United States)

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future

  17. First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Daniel H.; Lundstroem, Ulf; Burvall, Anna; Hertz, Hans M. [Department of Applied Physics, KTH Royal Institute of Technology/Albanova, 10691 Stockholm (Sweden); Westermark, Ulrica K.; Arsenian Henriksson, Marie [Department of Microbiology, Tumor and Cell Biology (MTC), Karolinska Institutet, 17177 Stockholm (Sweden)

    2013-02-15

    Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

  18. Design and testing of small scale fish meat bone separator useful for fish processing.

    Science.gov (United States)

    Ali Muhammed, M; Manjunatha, N; Murthy, K Venkatesh; Bhaskar, N

    2015-06-01

    The present study relates to the food processing machinery and, more specifically machine for producing boneless comminuted meat from raw fish fillet. This machine is of belt and drum type meat bone separator designed for small scale fish processing in a continuous mode. The basic principal involved in this machine is compression force. The electric geared motor consists of 1HP and the conveyor belt has a linear velocity of 19 to 22 m min(-1), which was sufficient to debone the fish effectively. During the meat bone separation trials an efficiency up to 75 % on dressed fish weight basis was observed and with a capacity to separate 70 kg h(-1) of meat from fish at the machine speed of 25 rpm. During the trials, it was demonstrated that there was no significant change in the proximate composition of comminuted fish meat when compared to unprocessed fish meat. This design has a greater emphasis on hygiene, provision for cleaning-in-place (CIP) and gives cost effective need and reliability for small scale industries to produce fish meat in turn used for their value added products.

  19. Animal Bone Remnants from Trench CLXII of the Bolgar City Site: Some New Methods of Archaeozoological Materials Processing and Evaluation

    OpenAIRE

    Yavorskaya Lilia V.

    2012-01-01

    It is for the first time in the study of animal bone remnants from the Bolgar city site that modern techniques have been applied, which have made it possible to solve archaeological and historical problems rather than purely biological ones. A detailed description of the work process based on these techniques and of the results obtained is offered. In particular, it has been found out that the cattle intended for slaughter in Bolgar had not been bred within the city limits but rather supplied...

  20. Scalable electrophysiology in intact small animals with nanoscale suspended electrode arrays

    Science.gov (United States)

    Gonzales, Daniel L.; Badhiwala, Krishna N.; Vercosa, Daniel G.; Avants, Benjamin W.; Liu, Zheng; Zhong, Weiwei; Robinson, Jacob T.

    2017-07-01

    Electrical measurements from large populations of animals would help reveal fundamental properties of the nervous system and neurological diseases. Small invertebrates are ideal for these large-scale studies; however, patch-clamp electrophysiology in microscopic animals typically requires invasive dissections and is low-throughput. To overcome these limitations, we present nano-SPEARs: suspended electrodes integrated into a scalable microfluidic device. Using this technology, we have made the first extracellular recordings of body-wall muscle electrophysiology inside an intact roundworm, Caenorhabditis elegans. We can also use nano-SPEARs to record from multiple animals in parallel and even from other species, such as Hydra littoralis. Furthermore, we use nano-SPEARs to establish the first electrophysiological phenotypes for C. elegans models for amyotrophic lateral sclerosis and Parkinson's disease, and show a partial rescue of the Parkinson's phenotype through drug treatment. These results demonstrate that nano-SPEARs provide the core technology for microchips that enable scalable, in vivo studies of neurobiology and neurological diseases.

  1. Small Animal Models for Human Metapneumovirus: Cotton Rat is More Permissive than Hamster and Mouse

    Science.gov (United States)

    Zhang, Yu; Niewiesk, Stefan; Li, Jianrong

    2014-01-01

    Human metapneumovirus (hMPV) is the second most prevalent causative agent of pediatric respiratory infections worldwide. Currently, there are no vaccines or antiviral drugs against this virus. One of the major hurdles in hMPV research is the difficulty to identify a robust small animal model to accurately evaluate the efficacy and safety of vaccines and therapeutics. In this study, we compared the replication and pathogenesis of hMPV in BALB/c mice, Syrian golden hamsters, and cotton rats. It was found that BALB/c mice are not permissive for hMPV infection despite the use of a high dose (6.5 log10 PFU) of virus for intranasal inoculation. In hamsters, hMPV replicated efficiently in nasal turbinates but demonstrated only limited replication in lungs. In cotton rats, hMPV replicated efficiently in both nasal turbinate and lung when intranasally administered with three different doses (4, 5, and 6 log10 PFU) of hMPV. Lungs of cotton rats infected by hMPV developed interstitial pneumonia with mononuclear cells infiltrates and increased lumen exudation. By immunohistochemistry, viral antigens were detected at the luminal surfaces of the bronchial epithelial cells in lungs. Vaccination of cotton rats with hMPV completely protected upper and lower respiratory tract from wildtype challenge. The immunization also elicited elevated serum neutralizing antibody. Collectively, these results demonstrated that cotton rat is a robust small animal model for hMPV infection. PMID:25438015

  2. Three-dimensional segmentation and skeletonization to build an airway tree data structure for small animals

    International Nuclear Information System (INIS)

    Chaturvedi, Ashutosh; Lee, Zhenghong

    2005-01-01

    Quantitative analysis of intrathoracic airway tree geometry is important for objective evaluation of bronchial tree structure and function. Currently, there is more human data than small animal data on airway morphometry. In this study, we implemented a semi-automatic approach to quantitatively describe airway tree geometry by using high-resolution computed tomography (CT) images to build a tree data structure for small animals such as rats and mice. Silicon lung casts of the excised lungs from a canine and a mouse were used for micro-CT imaging of the airway trees. The programming language IDL was used to implement a 3D region-growing threshold algorithm for segmenting out the airway lung volume from the CT data. Subsequently, a fully-parallel 3D thinning algorithm was implemented in order to complete the skeletonization of the segmented airways. A tree data structure was then created and saved by parsing through the skeletonized volume using the Python programming language. Pertinent information such as the length of all airway segments was stored in the data structure. This approach was shown to be accurate and efficient for up to six generations for the canine lung cast and ten generations for the mouse lung cast

  3. Potential Applications of Flat-Panel Volumetric CT in Morphologic, Functional Small Animal Imaging

    Directory of Open Access Journals (Sweden)

    Susanne Greschus

    2005-08-01

    Full Text Available Noninvasive radiologic imaging has recently gained considerable interest in basic, preclinical research for monitoring disease progression, therapeutic efficacy. In this report, we introduce flat-panel volumetric computed tomography (fpVCT as a powerful new tool for noninvasive imaging of different organ systems in preclinical research. The three-dimensional visualization that is achieved by isotropic high-resolution datasets is illustrated for the skeleton, chest, abdominal organs, brain of mice. The high image quality of chest scans enables the visualization of small lung nodules in an orthotopic lung cancer model, the reliable imaging of therapy side effects such as lung fibrosis. Using contrast-enhanced scans, fpVCT displayed the vascular trees of the brain, liver, kidney down to the subsegmental level. Functional application of fpVCT in dynamic contrast-enhanced scans of the rat brain delivered physiologically reliable data of perfusion, tissue blood volume. Beyond scanning of small animal models as demonstrated here, fpVCT provides the ability to image animals up to the size of primates.

  4. Online virtual isocenter based radiation field targeting for high performance small animal microirradiation

    Science.gov (United States)

    Stewart, James M. P.; Ansell, Steve; Lindsay, Patricia E.; Jaffray, David A.

    2015-12-01

    Advances in precision microirradiators for small animal radiation oncology studies have provided the framework for novel translational radiobiological studies. Such systems target radiation fields at the scale required for small animal investigations, typically through a combination of on-board computed tomography image guidance and fixed, interchangeable collimators. Robust targeting accuracy of these radiation fields remains challenging, particularly at the millimetre scale field sizes achievable by the majority of microirradiators. Consistent and reproducible targeting accuracy is further hindered as collimators are removed and inserted during a typical experimental workflow. This investigation quantified this targeting uncertainty and developed an online method based on a virtual treatment isocenter to actively ensure high performance targeting accuracy for all radiation field sizes. The results indicated that the two-dimensional field placement uncertainty was as high as 1.16 mm at isocenter, with simulations suggesting this error could be reduced to 0.20 mm using the online correction method. End-to-end targeting analysis of a ball bearing target on radiochromic film sections showed an improved targeting accuracy with the three-dimensional vector targeting error across six different collimators reduced from 0.56+/- 0.05 mm (mean  ±  SD) to 0.05+/- 0.05 mm for an isotropic imaging voxel size of 0.1 mm.

  5. Development of an Extracorporeal Perfusion Device for Small Animal Free Flaps.

    Directory of Open Access Journals (Sweden)

    Andreas M Fichter

    Full Text Available Extracorporeal perfusion (ECP might prolong the vital storage capabilities of composite free flaps, potentially opening a wide range of clinical applications. Aim of the study was the development a validated low-cost extracorporeal perfusion model for further research in small animal free flaps.After establishing optimal perfusion settings, a specially designed extracorporeal perfusion system was evaluated during 8-hour perfusion of rat epigastric flaps followed by microvascular free flap transfer. Controls comprised sham-operation, ischemia and in vivo perfusion. Flaps and perfusate (diluted blood were closely monitored by blood gas analysis, combined laser Doppler flowmetry and remission spectroscopy and Indocyanine-Green angiography. Evaluations were complemented by assessment of necrotic area and light microscopy at day 7.ECP was established and maintained for 8 hours with constant potassium and pH levels. Subsequent flap transfer was successful. Notably, the rate of necrosis of extracorporeally perfused flaps (27% was even lower than after in vivo perfusion (49%, although not statistically significant (P = 0,083. After sham-operation, only 6% of the total flap area became necrotic, while 8-hour ischemia led to total flap loss (98%. Angiographic and histological findings confirmed these observations.Vital storage capabilities of microvascular flaps can be prolonged by temporary ECP. Our study provides important insights on the pathophysiological processes during extracorporeal tissue perfusion and provides a validated small animal perfusion model for further studies.

  6. Evaluation of 3D reconstruction algorithms for a small animal PET camera

    International Nuclear Information System (INIS)

    Johnson, C.A.; Gandler, W.R.; Seidel, J.

    1996-01-01

    The use of paired, opposing position-sensitive phototube scintillation cameras (SCs) operating in coincidence for small animal imaging with positron emitters is currently under study. Because of the low sensitivity of the system even in 3D mode and the need to produce images with high resolution, it was postulated that a 3D expectation maximization (EM) reconstruction algorithm might be well suited for this application. We investigated four reconstruction algorithms for the 3D SC PET camera: 2D filtered back-projection (FBP), 2D ordered subset EM (OSEM), 3D reprojection (3DRP), and 3D OSEM. Noise was assessed for all slices by the coefficient of variation in a simulated uniform cylinder. Resolution was assessed from a simulation of 15 point sources in the warm background of the uniform cylinder. At comparable noise levels, the resolution achieved with OSEM (0.9-mm to 1.2-mm) is significantly better than that obtained with FBP or 3DRP (1.5-mm to 2.0-mm.) Images of a rat skull labeled with 18 F-fluoride suggest that 3D OSEM can improve image quality of a small animal PET camera

  7. Small-animal whole-body imaging using a photoacoustic full ring array system

    Science.gov (United States)

    Xia, Jun; Guo, Zijian; Aguirre, Andres; Zhu, Quing; Wang, Lihong V.

    2011-03-01

    In this report, we present a novel 3D photoacoustic computed tomography (PACT) system for small-animal whole-body imaging. The PACT system, based on a 512-element full-ring transducer array, received photoacoustic signals primarily from a 2-mm-thick slice. The light was generated by a pulse laser, and can either illuminate from the top or be reshaped to illuminate the sample from the side, using a conical lens and an optical condenser. The PACT system was capable of acquiring an in-plane image in 1.6 s; by scanning the sample in the elevational direction, a 3D tomographic image could be constructed. We tested the system by imaging a cylindrical phantom made of human hairs immersed in a scattering medium. The reconstructed image achieved an in-plane resolution of 0.1 mm and an elevational resolution of 1 mm. After deconvolution in the elevational direction, the 3D image was found to match well with the phantom. The system was also used to image a baby mouse in situ; the spinal cord and ribs can be seen easily in the reconstructed image. Our results demonstrate that the PACT system has the potential to be used for fast small-animal whole-body tomographic imaging.

  8. Investigation of incidence and risk factors for surgical glove perforation in small animal surgery.

    Science.gov (United States)

    Hayes, Galina M; Reynolds, Deborah; Moens, Noel M M; Singh, Ameet; Oblak, Michelle; Gibson, Thomas W G; Brisson, Brigitte A; Nazarali, Alim; Dewey, Cate

    2014-05-01

    To identify incidence and risk factors for surgical glove perforation in small animal surgery. Observational cohort study. Surgical gloves (n = 2132) worn in 363 surgical procedures. All gloves worn by operative personnel were assessed for perforation at end-procedure using a water leak test. Putative risk factors were recorded by a surgical team member. Associations between risk factors and perforation were assessed using multivariable multi-level random-effects logistic regression models to control for hierarchical data structure. At least 1 glove perforation occurred in 26.2% of procedures. Identified risk factors for glove perforation included increased surgical duration (surgery >1 hour OR = 1.79, 95% CI = 1.12-2.86), performing orthopedic procedures (OR = 1.88; 95% CI = 1.23-2.88), any procedure using powered instruments (OR = 1.93; 95% CI = 1.21-3.09) or surgical wire (OR = 3.02; 95% CI = 1.50-6.05), use of polyisoprene as a glove material (OR = 1.59, 95% CI = 1.05-2.39), and operative role as primary surgeon (OR = 2.01; 95% CI = 1.35-2.98). The ability of the wearer to detect perforations intraoperatively was poor, with a sensitivity of 30.8%. There is a high incidence of unrecognized glove perforations in small animal surgery. © Copyright 2014 by The American College of Veterinary Surgeons.

  9. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  10. Management and Level of Asian small-clawed otter (Aonyx cinereus Illinger, 1815 as Display Animal in Indonesia Conservation Institution

    Directory of Open Access Journals (Sweden)

    Ulfa Hansyari Ar-Rasyid

    2017-09-01

    Full Text Available Education and breeding become main reasons for asian small-clawed otter placement as display animal in zoo. Proper management is needed to maintain asian small-clawed otter welfare. This research objectives were to examine and assess asian small-clawed otter welfare in three Indonesia zoos. The study was conducted from December 2016 to February 2017 in Bandung Zoo, Ragunan Zoo and Ocean Dream Samudra Ancol. The methods of this research were literature review, interview and field observation. Data were analyzed using the suitability of management and animal welfare assessment. The result showed that there were three main management activities conducted at the three study locations, i.e., nutrition, housing, and health management. Bandung Zoo achieved the lowest score of asian small-clawed otter welfare (45,24% compared to Ragunan Zoo (62,24% and Ocean Dream Samudra (65,90%. Asian small-clawed otter welfare in three institutions were relatively low to fair category, this was due to the unfilled quality of food and water i.e.,  the type, amount, feeding frequency, diet and preparing of food; the unavailability of suitable and favorable environmental conditions; the care facilities provided could not ensure the health of animal; the appearance of abnormal behavior that affected the growth and breeding of animal; and animal had no freedom to behave as in their natural habitat. Keywords: animal display, animal welfare, Asian small-clawed otter, zoo 

  11. Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

    Science.gov (United States)

    Konik, Arda Bekir

    Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model

  12. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    International Nuclear Information System (INIS)

    Lalander, Cecilia Helena; Komakech, Allan John; Vinnerås, Björn

    2015-01-01

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies

  13. Dynamic {sup 18}F-fluoride small animal PET to noninvasively assess renal function in rats

    Energy Technology Data Exchange (ETDEWEB)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael [Klinik und Poliklinik fuer Nuklearmedizin, Muenster (Germany); Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert [Universitaetsklinikum Muenster, Medizinische Klinik und Poliklinik D, Experimentelle Nephrologie, Muenster (Germany)

    2008-12-15

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a {sup 18}F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq {sup 18}F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal {sup 18}F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide {sup 99m}Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ({sup 18}F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. {sup 18}F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  14. A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals

    Directory of Open Access Journals (Sweden)

    Yong-Jian Ma

    2016-01-01

    Full Text Available This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0±5.9 d rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0±4.0 d, and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0±2.9 d were statistically similar (all p>0.05 to and linearly correlated (r=0.96, p<0.01 with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0±2.7 d; RIB10, 33.0±1.3 d; and RIB20, 27.0±0.8 d. The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models.

  15. Image-guided small animal radiation research platform: calibration of treatment beam alignment

    International Nuclear Information System (INIS)

    Matinfar, Mohammad; Iordachita, Iulian; Kazanzides, Peter; Ford, Eric; Wong, John

    2009-01-01

    Small animal research allows detailed study of biological processes, disease progression and response to therapy with the potential to provide a natural bridge to the clinical environment. The small animal radiation research platform (SARRP) is a portable system for precision irradiation with beam sizes down to approximately 0.5 mm and optimally planned radiation with on-board cone-beam CT (CBCT) guidance. This paper focuses on the geometric calibration of the system for high-precision irradiation. A novel technique for the calibration of the treatment beam is presented, which employs an x-ray camera whose precise positioning need not be known. Using the camera system we acquired a digitally reconstructed 3D 'star shot' for gantry calibration and then developed a technique to align each beam to a common isocenter with the robotic animal positioning stages. The calibration incorporates localization by cone-beam CT guidance. Uncorrected offsets of the beams with respect to the calibration origin ranged from 0.4 mm to 5.2 mm. With corrections, these alignment errors can be reduced to the sub-millimeter range. The calibration technique was used to deliver a stereotactic-like arc treatment to a phantom constructed with EBT Gafchromic films. All beams were shown to intersect at a common isocenter with a measured beam (FWHM) of approximately 1.07 mm using the 0.5 mm collimated beam. The desired positioning accuracy of the SARRP is 0.25 mm and the results indicate an accuracy of 0.2 mm. To fully realize the radiation localization capabilities of the SARRP, precise geometric calibration is required, as with any such system. The x-ray camera-based technique presented here provides a straightforward and semi-automatic method for system calibration.

  16. SU-E-T-217: Intrinsic Respiratory Gating in Small Animal CT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y; Smith, M; Mistry, N [University of Maryland School of Medicine, Baltimore, MD (United States)

    2014-06-01

    Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable

  17. Dynamic 18F-fluoride small animal PET to noninvasively assess renal function in rats

    International Nuclear Information System (INIS)

    Schnoeckel, Uta; Stegger, Lars; Schaefers, Klaus P.; Hermann, Sven; Schober, Otmar; Schaefers, Michael; Reuter, Stefan; Schlatter, Eberhard; Gabriels, Gert

    2008-01-01

    Renal function can be quantified by both laboratory and scintigraphic methods. In the case of small animal diagnostics, scintigraphic image-based methods are ideal since they can assess split renal function, work noninvasively, and can be repeated. The aim of this study is to validate a 18 F-PET-based method to quantify renal function in rats. Fluoride clearance was calculated from a dynamic whole body listmode acquisition of 60 min length in a small animal PET scanner following an i.v. injection of 15 MBq 18 F-fluoride. Volumes of interest (VOIs) were placed in the left ventricle and the bladder as well as traced around the kidney contours. The respective time-activity curves (TAC) were calculated. The renal 18 F-clearance was calculated by the ratio of the total renal excreted activity (bladder VOI) and the integral of the blood TAC. PET-derived renal function was validated by intraindividual measurements of creatinine clearance (n=23), urea clearance (n=23), and tubular excretion rate (TER-MAG3). The split renal function was derived from the injection of the clinically available radionuclide 99m Tc-mercaptotriglycine by blood sampling and planar renography (n=8). In all animals studied, PET revealed high-quality TACs. PET-derived renal fluoride clearance was linearly correlated with intraindividual laboratory measures (PET vs. creatinine: r=0.78; PET vs. urea: r=0.73; PET vs. TER-MAG3: r=0.73). Split function was comparable ( 18 F-PET vs. MAG3-renography: r=0.98). PET-derived measures were highly reproducible. 18 F-PET is able to noninvasively assess renal function in rats and provides a significant potential for serial studies in different experimental scenarios. (orig.)

  18. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  19. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Energy Technology Data Exchange (ETDEWEB)

    Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Komakech, Allan John [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala (Uganda); Vinnerås, Björn [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden)

    2015-05-15

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.

  20. Collimator optimization for small animal radiation therapy at a micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Felix, Manuela C. [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Glatting, Gerhard [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Giordano, Frank A.; Wenz, Frederik; Fleckenstein, Jens [Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Brockmann, Marc A. [Heidelberg Univ., Mannheim (Germany). Dept. of Neuroradiology; University Medical Center Mainz (Germany). Dept. of Neuroradiology

    2017-05-01

    In radiation therapy of small animals treatment depths range from a few millimetres to several centimetres. In order to spare surrounding organs at risk steep dose gradients are necessary. To minimize the treatment time, and therefore the strain to the animals, a high dose rate is required. A description how these parameters can be optimized through an appropriate choice of collimators with different source surface distances (SSD) as well as different materials and geometries is presented. An industrial micro-CT unit (Y.Fox, YXLON GmbH, Hamburg, Germany) was converted into a precision irradiator for small animals. Different collimators of either stainless steel (Fe) with cylindrical bores (SSD = 42 mm) or tungsten (W) with conical bores (SSD = 14 mm) were evaluated. The dosimetry of very small radiation fields presents a challenge and was performed with GafChromic EBT3 films (Ashland, Vayne, KY, USA) in a water phantom. The films were calibrated with an ionization chamber in the uncollimated field. Treatments were performed via a rotation of the objects with a fixed radiation source. As expected, the shorter SSD of the W-collimators resulted in a (4.5 ± 1.6)-fold increase of the dose rates compared to the corresponding Fe-collimators. The ratios of the dose rates at 1 mm and 10 mm depth in the water phantom was (2.6 ± 0.2) for the Fe- and (4.5 ± 0.1) for the W-collimators. For rotational treatments in a cylindrical plastic phantom maximum dose rates of up to 1.2 Gy/min for Fe- and 5.1 Gy/min for W-collimators were measured. Choosing the smallest possible SSD leads to a high dose rate and a high surface dose, which is of advantage for the treatment of superficial target volumes. For larger SSD the dose rate is lower and the depth dose curve is shallower. This leads to a reduction of the surface dose and is best suited for treatments of deeper seated target volumes. Divergent collimator bores have, due to the reduced scatter within the collimators, a steeper

  1. The Korean herbal formulation Yukmijihwangtang stimulates longitudinal bone growth in animal models.

    Science.gov (United States)

    Cho, Sung-Min; Lee, Sun Haeng; Lee, Donghun; Lee, Ji Hong; Chang, Gyu Tae; Kim, Hocheol; Lee, Jin Yong

    2017-05-02

    Yukmijihwangtang (YJT) is a traditional Korean medicine that has been used to treat kidney-yin deficiency symptoms such as dizziness and tinnitus. In addition, because it is also thought to nourish kidney-yin, it has been used to treat short stature from congenital deficiency. This study evaluated the effects of YJT on longitudinal bone growth in rats. Female adolescent rats were randomly assigned to groups that received distilled water (per os [p.o.] twice a day; control), recombinant human growth hormone (rhGH; 20 μg/kg, subcutaneous [s.c.] once a day), or two different doses of YJT (100 or 300 mg/kg, p.o. twice a day). In each group, treatment was maintained for 4 days. Rats were injected intraperitoneally with 5-bromo-2'-deoxyuridine (BrdU; 50 mg/kg) to label proliferating chondrocytes on days 2 - 4. Tetracycline hydrochloride (20 mg/kg) was injected intraperitoneally to form fluorescent bands on the growth plates on day 3 for measuring the longitudinal bone growth rate. Expression of insulin-like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) in the growth plate was identified using immunohistochemistry. There was a significant increase in the rate of bone growth in the 300 mg/kg YJT group (523.8 ± 23.7 μm/day; P growth plate in the 300 mg/kg YJT and rhGH groups. YJT increased the longitudinal bone growth rate by stimulating chondrocyte proliferation with increasing increments of local IGF-1 and BMP-2 expression. Based on these findings, YJT may be a therapeutic candidate for the treatment of growth retardation during adolescence.

  2. Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry

    International Nuclear Information System (INIS)

    Angelis, G I; Kyme, A Z; Ryder, W J; Fulton, R R; Meikle, S R

    2014-01-01

    Attenuation correction in positron emission tomography brain imaging of freely moving animals is a very challenging problem since the torso of the animal is often within the field of view and introduces a non negligible attenuating factor that can degrade the quantitative accuracy of the reconstructed images. In the context of unrestrained small animal imaging, estimation of the attenuation correction factors without the need for a transmission scan is highly desirable. An attractive approach that avoids the need for a transmission scan involves the generation of the hull of the animal’s head based on the reconstructed motion corrected emission images. However, this approach ignores the attenuation introduced by the animal’s torso. In this work, we propose a virtual scanner geometry which moves in synchrony with the animal’s head and discriminates between those events that traversed only the animal’s head (and therefore can be accurately compensated for attenuation) and those that might have also traversed the animal’s torso. For each recorded pose of the animal’s head a new virtual scanner geometry is defined and therefore a new system matrix must be calculated leading to a time-varying system matrix. This new approach was evaluated on phantom data acquired on the microPET Focus 220 scanner using a custom-made phantom and step-wise motion. Results showed that when the animal’s torso is within the FOV and not appropriately accounted for during attenuation correction it can lead to bias of up to 10% . Attenuation correction was more accurate when the virtual scanner was employed leading to improved quantitative estimates (bias < 2%), without the need to account for the attenuation introduced by the extraneous compartment. Although the proposed method requires increased computational resources, it can provide a reliable approach towards quantitatively accurate attenuation correction for freely moving animal studies. (paper)

  3. A high resolution small animal radiation research platform (SARRP) with x-ray tomographic guidance capabilities

    Science.gov (United States)

    Wong, John; Armour, Elwood; Kazanzides, Peter; Iordachita, Iulian; Tryggestad, Erik; Deng, Hua; Matinfar, Mohammad; Kennedy, Christopher; Liu, Zejian; Chan, Timothy; Gray, Owen; Verhaegen, Frank; McNutt, Todd; Ford, Eric; DeWeese, Theodore L.

    2008-01-01

    Purpose To demonstrate the CT imaging, conformal irradiation and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods The SARRP employs a dual-focal spot, constant voltage x-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120° from vertical. Eighty to 100 kVp x-rays from the smaller 0.4 mm focal spot are used for imaging. Both 0.4 mm and 3.0 mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam (CB) CT imaging is achieved by rotating the horizontal animal between the stationary x-ray source and a flat-panel detector. Radiation beams range from 0.5 mm in diameter to (60 × 60) mm2. Dosimetry is measured with radio-chromic films. Monte Carlo dose calculations are employed for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results The SARRP spans 3 ft × 4 ft × 6 ft (WxLxH). Depending on filtration, the isocenter dose outputs at 1 cm depth in water range from 22 to 375 cGy/min from the smallest to the largest radiation fields. The 20% to 80% dose fall-off spans 0.16 mm. CBCT with (0.6 × 0.6 × 0.6) mm3 voxel resolution is acquired with less than 1 cGy. Treatment planning is performed at sub-mm resolution. Conclusions The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation. PMID:18640502

  4. Improved instrumentation for blood flow velocity measurements in the microcirculation of small animals

    International Nuclear Information System (INIS)

    Mesquita, Jayme Alves Jr. de; Bouskela, Eliete; Wajnberg, Eliane; Lopes de Melo, Pedro

    2007-01-01

    Microcirculation is the generic name of vessels with internal diameter less than 100 μm of the circulatory system, whose main functions are tissue nutrition and oxygen supply. In microcirculatory studies, it is important to know the amount of oxyhemoglobin present in the blood and how fast it is moving. The present work describes improvements introduced in a classical hardware-based instrument that has usually been used to monitor blood flow velocity in the microcirculation of small animals. It consists of a virtual instrument that can be easily incorporated into existing hardware-based systems, contributing to reduce operator related biases and allowing digital processing and storage. The design and calibration of the modified instrument are described as well as in vitro and in vivo results obtained with electrical models and small animals, respectively. Results obtained in in vivo studies showed that this new system is able to detect a small reduction in blood flow velocity comparing arteries and arterioles (p<0.002) and a further reduction in capillaries (p<0.0001). A significant increase in velocity comparing capillaries and venules (p<0.001) and venules and veins (p<0.001) was also observed. These results are in close agreement with biophysical principles. Moreover, the improvements introduced in the device allowed us to clearly observe changes in blood flow introduced by a pharmacological intervention, suggesting that the system has enough temporal resolution to track these microcirculatory events. These results were also in close conformity to physiology, confirming the high scientific potential of the modified system and indicating that this instrument can also be useful for pharmacological evaluations

  5. Radiobiological long-term accumulation of environmental alpha radioactivity in extracted human teeth and animal bones in Malaysia.

    Science.gov (United States)

    Almayahi, B A; Tajuddin, A A; Jaafar, M S

    2014-03-01

    In this study, the radiobiological analysis of natural alpha emitters in extracted human teeth and animal bones from Malaysia was estimated. The microdistributions of alpha particles in tooth and bone samples were measured using CR-39 alpha-particle track detectors. The lowest and highest alpha emission rates in teeth in the Kedah and Perak states were 0.0080 ± 0.0005 mBq cm(-2) and 0.061 ± 0.008 mBq cm(-2), whereas those of bones in the Perlis and Kedah states were 0.0140 ± 0.0001 mBq cm(-2) and 0.7700 ± 0.0282 mBq cm(-2), respectively. The average alpha emission rate in male teeth was 0.0209 ± 0.0008 mBq cm(-2), whereas that of female teeth was 0.0199 ± 0.0010 mBq cm(-2). The alpha emission rate in teeth is higher in smokers (0.0228 ± 0.0008 mBq cm(-2)) than in non-smokers (0.0179 ± 0.0008 mBq cm(-2)). Such difference was found statistically significant (p < 0.01). Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Scanning multiple mice in a small-animal PET scanner: Influence on image quality

    International Nuclear Information System (INIS)

    Siepel, Francoise J.; Lier, Monique G.J.T.B. van; Chen Mu; Disselhorst, Jonathan A.; Meeuwis, Antoi P.W.; Oyen, Wim J.G.; Boerman, Otto C.; Visser, Eric P.

    2010-01-01

    To achieve high throughput in small-animal positron emission tomography (PET), it may be advantageous to scan more than one animal in the scanner's field of view (FOV) at the same time. However, due to the additional activity and increase of Poisson noise, additional attenuating mass, extra photon scattering, and radial or axial displacement of the animals, a deterioration of image quality can be expected. In this study, the NEMA NU 4-2008 image quality (NU4IQ) phantom and up to three FDG-filled cylindrical 'mouse phantoms' were positioned in the FOV of the Siemens Inveon small-animal PET scanner to simulate scans with multiple mice. Five geometrical configurations were examined. In one configuration, the NU4IQ phantom was scanned separately and placed in the center of the FOV (1C). In two configurations, a mouse phantom was added with both phantoms displaced radially (2R) or axially (2A). In two other configurations, the NU4IQ phantom was scanned along with three mouse phantoms with all phantoms displaced radially (4R), or in a combination of radial and axial displacement (2R2A). Images were reconstructed using ordered subset expectation maximization in 2 dimensions (OSEM2D) and maximum a posteriori (MAP) reconstruction. Image quality parameters were obtained according to the NEMA NU 4-2008 guidelines. Optimum image quality was obtained for the 1C geometry. Image noise increased by the addition of phantoms and was the largest for the 4R configuration. Spatial resolution, reflected in the recovery coefficients for the FDG-filled rods, deteriorated by radial displacement of the NU4IQ phantom (2R, 2R2A, and 4R), most strongly for OSEM2D, and to a smaller extent for MAP reconstructions. Photon scatter, as indicated by the spill-over ratios in the non-radioactive water- and air-filled compartments, increased by the addition of phantoms, most strongly for the 4R configuration. Application of scatter correction substantially lowered the spill-over ratios, but caused an

  7. An animal experimental study of transient synovitis of hip using three phase bone imaging

    International Nuclear Information System (INIS)

    Liang Jiugen; Lu Bing; Lu Xiaohu; Liu Shangli

    1994-01-01

    A model of transient synovitis was established by means of injecting noradrenaline (NA) into the joint cavity of young dogs. Radionuclide three phase bone imaging was then used to observe the local blood supply of femoral head and histological examination was used to understand the natural course of the disease process. The result showed that there were transient synovitis of the hip and decrease of blood supply in the affected femoral head after NA injection, but the changes gradually returned to normal after 4 weeks. No evidence of femoral head necrosis had been noticed. It is suggested that serial quantitative analysis of three phase bone imaging may have good clinical value in the early diagnosis transient hip synovitis, as well as in the assessment of the stage of the disease etc

  8. Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

    Science.gov (United States)

    Du, Junwei; Schmall, Jeffrey P.; Yang, Yongfeng; Di, Kun; Roncali, Emilie; Mitchell, Gregory S.; Buckley, Steve; Jackson, Carl; Cherry, Simon R.

    2015-01-01

    Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm2 and the total size of the detector head is 47.8 × 46.3 mm2. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve

  9. Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

    International Nuclear Information System (INIS)

    Du, Junwei; Schmall, Jeffrey P.; Yang, Yongfeng; Di, Kun; Roncali, Emilie; Mitchell, Gregory S.; Buckley, Steve; Jackson, Carl; Cherry, Simon R.

    2015-01-01

    Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm 2 and the total size of the detector head is 47.8 × 46.3 mm 2 . Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can

  10. Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals.

    Science.gov (United States)

    Kujawska, Tamara; Secomski, Wojciech; Byra, Michał; Postema, Michiel; Nowicki, Andrzej

    2017-04-01

    A technique using pulsed High Intensity Focused Ultrasound (HIFU) to destroy deep-seated solid tumors is a promising noninvasive therapeutic approach. A main purpose of this study was to design and test a HIFU transducer suitable for preclinical studies of efficacy of tested, anti-cancer drugs, activated by HIFU beams, in the treatment of a variety of solid tumors implanted to various organs of small animals at the depth of the order of 1-2cm under the skin. To allow focusing of the beam, generated by such transducer, within treated tissue at different depths, a spherical, 2-MHz, 29-mm diameter annular phased array transducer was designed and built. To prove its potential for preclinical studies on small animals, multiple thermal lesions were induced in a pork loin ex vivo by heating beams of the same: 6W, or 12W, or 18W acoustic power and 25mm, 30mm, and 35mm focal lengths. Time delay for each annulus was controlled electronically to provide beam focusing within tissue at the depths of 10mm, 15mm, and 20mm. The exposure time required to induce local necrosis was determined at different depths using thermocouples. Location and extent of thermal lesions determined from numerical simulations were compared with those measured using ultrasound and magnetic resonance imaging techniques and verified by a digital caliper after cutting the tested tissue samples. Quantitative analysis of the results showed that the location and extent of necrotic lesions on the magnetic resonance images are consistent with those predicted numerically and measured by caliper. The edges of lesions were clearly outlined although on ultrasound images they were fuzzy. This allows to conclude that the use of the transducer designed offers an effective noninvasive tool not only to induce local necrotic lesions within treated tissue without damaging the surrounding tissue structures but also to test various chemotherapeutics activated by the HIFU beams in preclinical studies on small animals

  11. Adaptations in tibial cortical thickness and total volumetric bone density in postmenopausal South Asian women with small bone size.

    Science.gov (United States)

    Darling, Andrea L; Hakim, Ohood A; Horton, Khim; Gibbs, Michelle A; Cui, Liang; Berry, Jacqueline L; Lanham-New, Susan A; Hart, Kathryn H

    2013-07-01

    There is some evidence that South Asian women may have an increased risk of osteoporosis compared with Caucasian women, although whether South Asians are at increased risk of fracture is not clear. It is unknown whether older South Asian women differ from Caucasian women in bone geometry. This is the first study, to the authors' knowledge, to use peripheral Quantitative Computed Tomography (pQCT) to measure radial and tibial bone geometry in postmenopausal South Asian women. In comparison to Caucasian women, Asian women had smaller bone size at the 4% (-18% pAsians had increased cortical thickness (-17% p=0.04) at the 38% tibia, (in proportion to bone size (-30% p=0.003)). Furthermore, at the 4% and 14% tibia there were increased total densities (+12% to +29% pAsians. These differences at the 14% and 38% (but not 4%) remained statistically significant after adjustment for Body Mass Index (BMI). These adaptations are similar to those seen previously in Chinese women. Asian women had reduced strength at the radius and tibia, evidenced by the 20-40% reduction in both polar Strength Strain Index (SSIp) and fracture load (under bending). Overall, the smaller bone size in South Asians is likely to be detrimental to bone strength, despite some adaptations in tibial cortical thickness and tibial and radial density which may partially compensate for this. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Time-dependent cytokine expression in bone of experimental animals after hydroxyapatite (Hap) implantation

    International Nuclear Information System (INIS)

    Pilmane, M; Salms, G; Salma, I; Skagers, A; Locs, J; Loca, D; Berzina-Cimdina, L

    2011-01-01

    Proinflammatory cytokines mediate bone loss around the implants in patients with peri-implant disease. However, there is no complete data about the expression of cytokines into the bone around the implants. The aim of this work was to investigate the distribution and appearance of inflammatory cytokines and anti-inflammatory proteins in the bone of jaw of experimental rabbits in different time periods after HAp implantation. Material was obtained from 8 rabbits in lower jaw 6 and 8 months after HAp implants were placed. Tissues were processed for immunohistochemical detection of tumor necrosis factor alfa (TNFα), Interleukin 1, 6, 8, 10 (IL-1, IL-6, IL-8, IL-10) and defensin 2. Results demonstrated practically unchanged expression of IL-6 and IL-10 between both - experimental and control side 6 months after implantation, while IL-1 and IL-8 notably increased in control side. IL-1 and IL-10 expression did not change in either the experimental side nor the controle side after 8 months HAP implantation, but IL-6 and IL-8 demonstrated a decrease in the control sites. Only IL-8 was elevated with time in experimental sites, while IL-10 showed individual variations in 2 cases.

  13. Time-dependent cytokine expression in bone of experimental animals after hydroxyapatite (Hap) implantation

    Energy Technology Data Exchange (ETDEWEB)

    Pilmane, M [Riga Stradins University, Institute of Anatomy and Anthropology, Dzirciema 16, LV-1007, Riga (Latvia); Salms, G; Salma, I; Skagers, A [Riga Stradins University, Department of Oral and Maxillofacial Surgery, Dzirciema 20. LV-1007, Riga (Latvia); Locs, J; Loca, D; Berzina-Cimdina, L, E-mail: pilmane@latnet.lv [Riga Technical University, Riga Biomaterials innovation and development centre, Pulka 3/3, LV-1007, Riga (Latvia)

    2011-06-23

    Proinflammatory cytokines mediate bone loss around the implants in patients with peri-implant disease. However, there is no complete data about the expression of cytokines into the bone around the implants. The aim of this work was to investigate the distribution and appearance of inflammatory cytokines and anti-inflammatory proteins in the bone of jaw of experimental rabbits in different time periods after HAp implantation. Material was obtained from 8 rabbits in lower jaw 6 and 8 months after HAp implants were placed. Tissues were processed for immunohistochemical detection of tumor necrosis factor alfa (TNF{alpha}), Interleukin 1, 6, 8, 10 (IL-1, IL-6, IL-8, IL-10) and defensin 2. Results demonstrated practically unchanged expression of IL-6 and IL-10 between both - experimental and control side 6 months after implantation, while IL-1 and IL-8 notably increased in control side. IL-1 and IL-10 expression did not change in either the experimental side nor the controle side after 8 months HAP implantation, but IL-6 and IL-8 demonstrated a decrease in the control sites. Only IL-8 was elevated with time in experimental sites, while IL-10 showed individual variations in 2 cases.

  14. Feasibility of small animal cranial irradiation with the microRT system

    International Nuclear Information System (INIS)

    Kiehl, Erich L.; Stojadinovic, Strahinja; Malinowski, Kathleen T.; Limbrick, David; Jost, Sarah C.; Garbow, Joel R.; Rubin, Joshua B.; Deasy, Joseph O.; Khullar, Divya; Izaguirre, Enrique W.; Parikh, Parag J.; Low, Daniel A.; Hope, Andrew J.

    2008-01-01

    Purpose: To develop and validate methods for small-animal CNS radiotherapy using the microRT system. Materials and Methods: A custom head immobilizer was designed and built to integrate with a pre-existing microRT animal couch. The Delrin couch-immobilizer assembly, compatible with multiple imaging modalities (CT, microCT, microMR, microPET, microSPECT, optical), was first imaged via CT in order to verify the safety and reproducibility of the immobilization method. Once verified, the subject animals were CT-scanned while positioned within the couch-immobilizer assembly for treatment planning purposes. The resultant images were then imported into CERR, an in-house-developed research treatment planning system, and registered to the microRTP treatment planning space using rigid registration. The targeted brain was then contoured and conformal radiotherapy plans were constructed for two separate studies: (1) a whole-brain irradiation comprised of two lateral beams at the 90 degree sign and 270 degree sign microRT treatment positions and (2) a hemispheric (left-brain) irradiation comprised of a single A-P vertex beam at the 0 degree sign microRT treatment position. During treatment, subject animals (n=48) were positioned to the CERR-generated treatment coordinates using the three-axis microRT motor positioning system and were irradiated using a clinical Ir-192 high-dose-rate remote after-loading system. The radiation treatment course consisted of 5 Gy fractions, 3 days per week. 90% of the subjects received a total dose of 30 Gy and 10% received a dose of 60 Gy. Results: Image analysis verified the safety and reproducibility of the immobilizer. CT scans generated from repeated reloading and repositioning of the same subject animal in the couch-immobilizer assembly were fused to a baseline CT. The resultant analysis revealed a 0.09 mm average, center-of-mass translocation and negligible volumetric error in the contoured, murine brain. The experimental use of the head

  15. Radiobiological long-term accumulation of environmental alpha radioactivity in extracted human teeth and animal bones in Malaysia

    International Nuclear Information System (INIS)

    Almayahi, B.A.; Tajuddin, A.A.; Jaafar, M.S.

    2014-01-01

    In this study, the radiobiological analysis of natural alpha emitters in extracted human teeth and animal bones from Malaysia was estimated. The microdistributions of alpha particles in tooth and bone samples were measured using CR-39 alpha-particle track detectors. The lowest and highest alpha emission rates in teeth in the Kedah and Perak states were 0.0080 ± 0.0005 mBq cm −2 and 0.061 ± 0.008 mBq cm −2 , whereas those of bones in the Perlis and Kedah states were 0.0140 ± 0.0001 mBq cm −2 and 0.7700 ± 0.0282 mBq cm −2 , respectively. The average alpha emission rate in male teeth was 0.0209 ± 0.0008 mBq cm −2 , whereas that of female teeth was 0.0199 ± 0.0010 mBq cm −2 . The alpha emission rate in teeth is higher in smokers (0.0228 ± 0.0008 mBq cm −2 ) than in non-smokers (0.0179 ± 0.0008 mBq cm −2 ). Such difference was found statistically significant (p < 0.01). - Highlights: • Alpha emission rates in teeth from smokers slightly higher than non-smokers. • Difference between alpha rates in male and female tooth not statistically significant. • Alpha particles have the same effect at any age. • Difference between alpha rates in bones was statistically significant

  16. Bone Marrow Derivation of Interstitial Cells of Cajal in Small Intestine Following Intestinal Injury

    Directory of Open Access Journals (Sweden)

    Dengqun Liu

    2010-01-01

    Full Text Available Interstitial cells of Cajal (ICCs in gastrointestinal tract are specialized cells serving as pacemaker cells. The origin of ICCs is currently not fully characterized. In this work, we aimed to study whether bone marrow-derived cells (BMDCs could contribute to the origin of ICCs in the muscular plexus of small intestine using GFP-C57BL/6 chimeric mice.Engraftment of BMDCs in the intestine was investigated for GFP expression. GFP positive bone marrow mononuclear cells reached a proportion of 95.65%±3.72% at different times in chimerism. Donor-derived cells distributed widely in all the layers of the gastrointestinal tract. There were GFP positive BMDCs in the myenteric plexus, which resembled characteristics of ICCs, including myenteric location, c-Kit positive staining, and ramified morphology. Donor-derived ICCs in the myenteric plexus contributed to a percentage ranging 9.25%±4.9% of all the ICCs in the myenteric plexus. In conclusion, here we described that donor-derived BMDCs might differentiate into gastrointestinal ICCs after radiation injury, which provided an alternative source for the origin of the ICCs in the muscular plexus of adult intestine. These results further identified the plasticity of BMDCs and indicated therapeutic implications of BMDCs for the gastrointestinal dysmotility caused by ICCs disorders.

  17. STTARR: a radiation treatment and multi-modal imaging facility for fast tracking novel agent development in small animal models

    International Nuclear Information System (INIS)

    Yeung, Ivan; McKee, Trevor; Jaffray, David; Hill, Richard

    2014-01-01

    Small animal models play a pivotal role in the pipeline development of novel agents and strategies in personalized cancer therapy. The Spatio-Temporal Targeting and Amplification of Radiation Response Program (STTARR) consists of an animal imaging and precision radiation facility designed to provide innovative biologic imaging and targeted radiation treatment strategies in small animals. The design is to mirror the imaging and radiation treatment facility in a modern cancer center. The STTARR features imaging equipment of small animal scale including CT, MRI, PET, SPECT, Optical devices as well as image guided irradiators. The fleet of imaging and irradiation equipment provides a platform for identification of biological targets of the specific molecular pathways that influence both tumor progression and a patient's response to radiation therapy. Examples will be given in the utilization of the imaging facilities for development in novel approaches in cancer therapy including a PET-FAZA study for hypoxia measurement in a pancreatic adenocarcinoma xenograft model. In addition, the cone-beam image guided small animal irradiator developed at our institute will also be described. The animal platform (couch) provides motion in 3 dimensions to position the animal to the isocentre of the beam. A pair of rotational arms supporting the X-ray/detector pair enables acquisition of cone-beam images of the animal which give rise to image guided precision of 0.5 mm. The irradiation energy ranges from 50 to 225 kVp at a dose rate from 10-400 cGy/min. The gantry is able to direct X-ray beam of different directions to give conformal radiation treatment to the animal. A dedicated treatment planning system is able to perform treatment planning and provide commonly used clinical metrics in the animal treatment plan. Examples will be given to highlight the use of the image guided irradiator for research of drug/irradiation regimen in animal models. (author)

  18. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  19. Contribution of customised dosimetry for small animal to the treatments of cancers by metabolic radiotherapy

    International Nuclear Information System (INIS)

    Boutaleb, Samir

    2010-01-01

    This research thesis first reports a bibliographical study which addressed the use of ionizing radiations in cancer therapy (evolution from ionizing radiation to metabolic radiotherapy, biological and physical parameters, and absorbed dose in metabolic radiotherapy) and the role imagery has in customised dosimetry (absorbed dose calculation methods, determination of cumulative activity, dosimetric models for S factor calculation). Then, the author presents a software which has been specifically developed for the creation of dosimetric models, and reports its validation. He reports the comparison between different dosimetric models in the case of mice. He highlights two applications of the developed tool: radio-immunotherapy and metabolic radiotherapy. He finally proposes a general discussion on the impact of small animal dosimetry on metabolic radiotherapy [fr

  20. Design and testing of a 750MHz CW-EPR digital console for small animal imaging.

    Science.gov (United States)

    Sato-Akaba, Hideo; Emoto, Miho C; Hirata, Hiroshi; Fujii, Hirotada G

    2017-11-01

    This paper describes the development of a digital console for three-dimensional (3D) continuous wave electron paramagnetic resonance (CW-EPR) imaging of a small animal to improve the signal-to-noise ratio and lower the cost of the EPR imaging system. A RF generation board, an RF acquisition board and a digital signal processing (DSP) & control board were built for the digital EPR detection. Direct sampling of the reflected RF signal from a resonator (approximately 750MHz), which contains the EPR signal, was carried out using a band-pass subsampling method. A direct automatic control system to reduce the reflection from the resonator was proposed and implemented in the digital EPR detection scheme. All DSP tasks were carried out in field programmable gate array ICs. In vivo 3D imaging of nitroxyl radicals in a mouse's head was successfully performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Design and testing of a 750 MHz CW-EPR digital console for small animal imaging

    Science.gov (United States)

    Sato-Akaba, Hideo; Emoto, Miho C.; Hirata, Hiroshi; Fujii, Hirotada G.

    2017-11-01

    This paper describes the development of a digital console for three-dimensional (3D) continuous wave electron paramagnetic resonance (CW-EPR) imaging of a small animal to improve the signal-to-noise ratio and lower the cost of the EPR imaging system. A RF generation board, an RF acquisition board and a digital signal processing (DSP) & control board were built for the digital EPR detection. Direct sampling of the reflected RF signal from a resonator (approximately 750 MHz), which contains the EPR signal, was carried out using a band-pass subsampling method. A direct automatic control system to reduce the reflection from the resonator was proposed and implemented in the digital EPR detection scheme. All DSP tasks were carried out in field programmable gate array ICs. In vivo 3D imaging of nitroxyl radicals in a mouse's head was successfully performed.

  2. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  3. Measurement of evaporative water loss in small animals by dew-point hygrometry.

    Science.gov (United States)

    Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W

    1977-08-01

    This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.

  4. Establishing a small animal model for evaluating protective immunity against mumps virus.

    Directory of Open Access Journals (Sweden)

    Adrian Pickar

    Full Text Available Although mumps vaccines have been used for several decades, protective immune correlates have not been defined. Recently, mumps outbreaks have occurred in vaccinated populations. To better understand the causes of the outbreaks and to develop means to control outbreaks in mumps vaccine immunized populations, defining protective immune correlates will be critical. Unfortunately, no small animal model for assessing mumps immunity exists. In this study, we evaluated use of type I interferon (IFN alpha/beta receptor knockout mice (IFN-α/βR-/- for such a model. We found these mice to be susceptible to mumps virus administered intranasally and intracranially. Passive transfer of purified IgG from immunized mice protected naïve mice from mumps virus infection, confirming the role of antibody in protection and demonstrating the potential for this model to evaluate mumps immunity.

  5. Development of Input Function Measurement System for Small Animal PET Study

    International Nuclear Information System (INIS)

    Kim, Jong Guk; Kim, Byung Su; Kim, Jin Su

    2010-01-01

    For quantitative measurement of radioactivity concentration in tissue and a validated tracer kinetic model, the high sensitive detection system has been required for blood sampling. With the accurate measurement of time activity curves (TACs) of labeled compounds in blood (plasma) enable to provide quantitative information on biological parameters of interest in local tissue. Especially, the development of new tracers for PET imaging requires knowledge of the kinetics of the tracer in the body and in arterial blood and plasma. Conventional approaches of obtaining an input function are to sample arterial blood sequentially by manual as a function of time. Several continuous blood sampling systems have been developed and used in nuclear medicine research field to overcome the limited temporal resolution in sampling by the conventional method. In this work, we developed the high sensitive and unique geometric design of GSO detector for small animal blood activity measurement

  6. First results in the application of silicon photomultiplier matrices to small animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Llosa, G. [University of Pisa, Department of Physics, Pisa (Italy)], E-mail: gabriela.llosa@pi.infn.it; Belcari, N.; Bisogni, M.G. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Collazuol, G. [University of Pisa, Department of Physics, Pisa (Italy); Scuola Normale Superiore, Pisa (Italy); Marcatili, S. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy); Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N. [FBK irst, Trento (Italy); Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F. [Laboratoire de l' Accelerateur Lineaire, IN2P3-CNRS, Orsay (France); Del Guerra, A. [University of Pisa, Department of Physics, Pisa (Italy); INFN Pisa (Italy)

    2009-10-21

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  7. First results in the application of silicon photomultiplier matrices to small animal PET

    International Nuclear Information System (INIS)

    Llosa, G.; Belcari, N.; Bisogni, M.G.; Collazuol, G.; Marcatili, S.; Boscardin, M.; Melchiorri, M.; Tarolli, A.; Piemonte, C.; Zorzi, N.; Barrillon, P.; Bondil-Blin, S.; Chaumat, V.; La Taille, C. de; Dinu, N.; Puill, V.; Vagnucci, J-F.; Del Guerra, A.

    2009-01-01

    A very high resolution small animal PET scanner that employs matrices of silicon photomultipliers as photodetectors is under development at the University of Pisa and INFN Pisa. The first SiPM matrices composed of 16 (4x4)1mmx1mm pixel elements on a common substrate have been produced at FBK-irst, and are being evaluated for this application. The MAROC2 ASIC developed at LAL-Orsay has been employed for the readout of the SiPM matrices. The devices have been tested with pixelated and continuous LYSO crystals. The results show the good performance of the matrices and lead to the fabrication of matrices with 64 SiPM elements.

  8. Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo

    Science.gov (United States)

    Xia, Jun; Chatni, Muhammad R.; Maslov, Konstantin; Guo, Zijian; Wang, Kun; Anastasio, Mark; Wang, Lihong V.

    2012-05-01

    We report a novel small-animal whole-body imaging system called ring-shaped confocal photoacoustic computed tomography (RC-PACT). RC-PACT is based on a confocal design of free-space ring-shaped light illumination and 512-element full-ring ultrasonic array signal detection. The free-space light illumination maximizes the light delivery efficiency, and the full-ring signal detection ensures a full two-dimensional view aperture for accurate image reconstruction. Using cylindrically focused array elements, RC-PACT can image a thin cross section with 0.10 to 0.25 mm in-plane resolutions and 1.6 s/frame acquisition time. By translating the mouse along the elevational direction, RC-PACT provides a series of cross-sectional images of the brain, liver, kidneys, and bladder.

  9. Efficient system modeling for a small animal PET scanner with tapered DOI detectors

    International Nuclear Information System (INIS)

    Zhang, Mengxi; Zhou, Jian; Yang, Yongfeng; Qi, Jinyi; Rodríguez-Villafuerte, Mercedes

    2016-01-01

    A prototype small animal positron emission tomography (PET) scanner for mouse brain imaging has been developed at UC Davis. The new scanner uses tapered detector arrays with depth of interaction (DOI) measurement. In this paper, we present an efficient system model for the tapered PET scanner using matrix factorization and a virtual scanner geometry. The factored system matrix mainly consists of two components: a sinogram blurring matrix and a geometrical matrix. The geometric matrix is based on a virtual scanner geometry. The sinogram blurring matrix is estimated by matrix factorization. We investigate the performance of different virtual scanner geometries. Both simulation study and real data experiments are performed in the fully 3D mode to study the image quality under different system models. The results indicate that the proposed matrix factorization can maintain image quality while substantially reduce the image reconstruction time and system matrix storage cost. The proposed method can be also applied to other PET scanners with DOI measurement. (paper)

  10. Programmable electronics for low-cost small animal PET/SPECT imaging

    International Nuclear Information System (INIS)

    Guerra, Pedro; Rubio, Jose L.; Kontaxakis, Georgios; Ortuno, Juan E.; Ledesma, Maria J.; Santos, Andres

    2006-01-01

    This work describes and characterizes the detector module of a novel positron/single photon emission (PET/SPECT) scanner for small animals. This detector consists of a YAP/LSO phoswich, a photomultiplier and acquisition front-end, and will be used as building block of a low-cost hybrid tomograph. The front-end processes data sampled at a fixed frequency, where a state-of-the-art programmable device estimates scintillation pulse parameters by means of digital algorithms. Finally, the estimated properties of the proposed detector module are used to model a rotating four-head scanner. The performance of the proposed PET/SPECT scanner is estimated and first results are promising in both modalities, deserving further research and optimization

  11. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    International Nuclear Information System (INIS)

    Kitchen, M J; Habib, A; Lewis, R A; Fouras, A; Dubsky, S; Wallace, M J; Hooper, S B

    2010-01-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  12. Implementation and assessment of an animal management system for small-animal micro-CT / micro-SPECT imaging

    Science.gov (United States)

    Holdsworth, David W.; Detombe, Sarah A.; Chiodo, Chris; Fricke, Stanley T.; Drangova, Maria

    2011-03-01

    Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during pre-clinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/-19 HU) and acceptable artifact from high-density components within the AMS (e.g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/-0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.

  13. New experimental model for single liver lobe hyperthermia in small animals using non-directional microwaves.

    Directory of Open Access Journals (Sweden)

    Ionuț Tudorancea

    Full Text Available Our aim was to develop a new experimental model for in vivo hyperthermia using non-directional microwaves, applicable to small experimental animals. We present an affordable approach for targeted microwave heat delivery to an isolated liver lobe in rat, which allows rapid, precise and stable tissue temperature control.A new experimental model is proposed. We used a commercial available magnetron generating 2450 MHz, with 4.4V and 14A in the filament and 4500V anodic voltage. Modifications were required in order to adjust tissue heating such as to prevent overheating and to allow for fine adjustments according to real-time target temperature. The heating is controlled using a virtual instrument application implemented in LabView® and responds to 0.1° C variations in the target. Ten healthy adult male Wistar rats, weighing 250-270 g were used in this study. The middle liver lobe was the target for controlled heating, while the rest of the living animal was protected.In vivo microwave delivery using our experimental setting is safe for the animals. Target tissue temperature rises from 30°C to 40°C with 3.375°C / second (R2 = 0.9551, while the increment is lower it the next two intervals (40-42°C and 42-44°C with 0.291°C/ s (R2 = 0.9337 and 0.136°C/ s (R2 = 0.7894 respectively, when testing in sequences. After reaching the desired temperature, controlled microwave delivery insures a very stable temperature during the experiments.We have developed an inexpensive and easy to manufacture system for targeted hyperthermia using non-directional microwave radiation. This system allows for fine and stable temperature adjustments within the target tissue and is ideal for experimental models testing below or above threshold hyperthermia.

  14. Development of a Compton suppression whole body counting for small animals

    International Nuclear Information System (INIS)

    Martini, Elaine

    1995-01-01

    The basic operation, design and construction of the plastic scintillator detector is described. In order to increase the sensitivity of this detector, two blocks of plastic scintillator have been assembled to act as a anticompton system. The detectors were produced by polymerisation of styrene monomer with PPO (2,5 diphenyl-oxazole) and POPOP (1,4 bis (-5 phenyl-2- oxazoly)benzene) in proportions of 0.5 and 0.05 respectively. The transparency of this detector was evaluated by excitation of the 241 Am source located directly in the back surface plastic coupled to a photomultiplier. The light attenuation according to the detector thickness has fitted to a two-exponential function: relative height pulse = 0,519 e -0.0016 + 0.481 e -0.02112.x . Four radioactive sources 2 2 Na, 54 Mn, 137 Cs and 131 I were used to evaluate the performance of this system. The Compton reduction factor, determined by the ratio of the energy peak values of suppressed and unsuppressed spectra was 1.16. The Compton suppression factor determined by the ratio of the net photopeak area to the area of an equal spectra width in the Compton continuum, was approximately 1.208 ± 0.109. The sensitivity of the system, defined as the least amount of a radioactivity that can be quantified in the photopeak region, was 9.44 cps. First, the detector was assembled to be applied in biological studies of whole body counter measurements of small animals. Using a phantom, (small animal simulator) and a punctual 137 Cs source, located in the central region of the well counter the geometrical efficiency detector was about 5%. (author)

  15. Small animal SPECT and its place in the matrix of molecular imaging technologies

    International Nuclear Information System (INIS)

    Meikle, Steven R; Kench, Peter; Kassiou, Michael; Banati, Richard B

    2005-01-01

    Molecular imaging refers to the use of non-invasive imaging techniques to detect signals that originate from molecules, often in the form of an injected tracer, and observe their interaction with a specific cellular target in vivo. Differences in the underlying physical principles of these measurement techniques determine the sensitivity, specificity and length of possible observation of the signal, characteristics that have to be traded off according to the biological question under study. Here, we describe the specific characteristics of single photon emission computed tomography (SPECT) relative to other molecular imaging technologies. SPECT is based on the tracer principle and external radiation detection. It is capable of measuring the biodistribution of minute ( -10 molar) concentrations of radio-labelled biomolecules in vivo with sub-millimetre resolution and quantifying the molecular kinetic processes in which they participate. Like some other imaging techniques, SPECT was originally developed for human use and was subsequently adapted for imaging small laboratory animals at high spatial resolution for basic and translational research. Its unique capabilities include (i) the ability to image endogenous ligands such as peptides and antibodies due to the relative ease of labelling these molecules with technetium or iodine (ii) the ability to measure relatively slow kinetic processes (compared with positron emission tomography, for example) due to the long half-life of the commonly used isotopes and (iii) the ability to probe two or more molecular pathways simultaneously by detecting isotopes with different emission energies. In this paper, we review the technology developments and design tradeoffs that led to the current state-of-the-art in SPECT small animal scanning and describe the position SPECT occupies within the matrix of molecular imaging technologies. (topical review)

  16. SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Jermoumi, M; Ngwa, W [University of Massachusetts Lowell, MA (United States); Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States); Korideck, H; Zygmanski, P; Berbeco, R; Makrigiorgos, G; Cormack, R [Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States)

    2014-06-01

    Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests.

  17. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    International Nuclear Information System (INIS)

    Aide, Nicolas; Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard; Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver; Beyer, Thomas; Kinross, Kathryn; Hicks, Rodney J.

    2010-01-01

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of 68 Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR air and SOR water were 5.3 and 7.5%, respectively. A strong correlation (r 2 = 0.97, p 2 = 0.98; slope = 0.89, p 2 = 0.96; slope = 0.62, p 68 Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  18. SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

    International Nuclear Information System (INIS)

    Jermoumi, M; Ngwa, W; Korideck, H; Zygmanski, P; Berbeco, R; Makrigiorgos, G; Cormack, R

    2014-01-01

    Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests

  19. Work environment and occupational risk assessment for small animal Portuguese veterinary activities.

    Science.gov (United States)

    Macedo, Angela C; Mota, Vânia T; Tavares, João M; Machado, Osvaldo L; Malcata, Francisco X; Cristo, Marinela P; Mayan, Olga N

    2018-03-01

    The professional work of small animal veterinary staff encompasses a wide diversity of demanding tasks. This has prompted a number of studies covering physical, chemical, biological, ergonomic, or psychological hazards, as well as their health effects upon veterinary workers. However, such results were obtained from self-reported surveys (via paper or online). This study reports the identification of potential hazards and provides a risk assessment of 15 veterinary clinics based on data from walk-through surveys, interviews with workers, and quantification of indoor air quality parameters including concentration of volatile organic compounds (total, isoflurane, and glutaraldehyde). The risk arising from X-ray exposure was unacceptable in seven clinics; X-ray examination should be discontinued in the absence of isolated radiation rooms, poor safety practices, and lack of personal protective equipment. Ergonomic-related hazards and work practices should be revised as soon as possible, considering that improper postures, as well as moving and lifting heavy animals are major causes of musculoskeletal disorders. The risk levels were, in general, small or medium (acceptable) with regard to exposure to physical hazards (such as bites, scratches, cuts, and burns) and biological hazards. It was observed that the indoor air quality parameters including temperature, respirable particulate matter and total volatile organic compounds do not indicate a comfortable workplace environment, requiring clinics' attention to keep the safe environment. The veterinarians and nurses were exposed to isoflurane (above 2 ppm) during surgery if an extractor system for waste gas was used instead of a scavenging system. Finally, veterinary workers did not possess any type of training on occupational safety and health issues, even though they recognized its importance.

  20. A clinical gamma camera-based pinhole collimated system for high resolution small animal SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J.; Galvis-Alonso, O.Y., E-mail: mejia_famerp@yahoo.com.b [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Biologia Molecular; Castro, A.A. de; Simoes, M.V. [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Dept. de Clinica Medica; Leite, J.P. [Universidade de Sao Paulo (FMRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Dept. de Neurociencias e Ciencias do Comportamento; Braga, J. [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil). Div. de Astrofisica

    2010-11-15

    The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target's three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology. (author)

  1. Development and applications of TOHR, an original emission tomography system, adapted to small animals

    International Nuclear Information System (INIS)

    Ploux, Lydie

    1997-01-01

    For many neuro-biological studies, it is necessary to link microscopic aspects of the brain's organization with integrated brain functions. Details of the former are obtained by in vitro and in situ molecular biology techniques, whereas the latter are acquired through behavioural studies. In vivo radio-imaging methods, like emission tomography are the ideal tools to investigate the links between these two levels of brain organization. The work which is presented here focuses on a new approach of emission tomography adapted to small animal studies: TOHR (French, acronym for TOmographe Haute Resolution). The principle is based on the use of a large solid angle, high resolution and high efficiency focusing collimator. High resolution and high signal to noise ratio are improved by using nuclides having a two-photon decay with small angular correlation ( 125 I, 123 I, 111 In,...). The image is built step-by-step, by moving the animal relative to the collimator focal point. First, numerical simulation showed the possibility of reaching sub-millimetric resolutions; these results led to the collimator geometry (at present 10 over the 20 faces of an icosahedron, 15 faces in the future). Then, a prototype of TOHR has been built and characterized. Its performance is very close to the numerical prediction: spatial resolution of 1.4 mm and detection efficiency 0.64%. Finally, experiments on a rat thyroid allowed the preparation and realization of the first experiments on a rat striatum. The good quality of these images shows that it is now possible to evaluate TOHR capabilities on a dopaminergic neuron degeneration model in rats in the field of neuro-degenerative disease studies. (author)

  2. Implementation of Cascade Gamma and Positron Range Corrections for I-124 Small Animal PET

    Science.gov (United States)

    Harzmann, S.; Braun, F.; Zakhnini, A.; Weber, W. A.; Pietrzyk, U.; Mix, M.

    2014-02-01

    Small animal Positron Emission Tomography (PET) should provide accurate quantification of regional radiotracer concentrations and high spatial resolution. This is challenging for non-pure positron emitters with high positron endpoint energies, such as I-124: On the one hand the cascade gammas emitted from this isotope can produce coincidence events with the 511 keV annihilation photons leading to quantification errors. On the other hand the long range of the high energy positron degrades spatial resolution. This paper presents the implementation of a comprehensive correction technique for both of these effects. The established corrections include a modified sinogram-based tail-fitting approach to correct for scatter, random and cascade gamma coincidences and a compensation for resolution degradation effects during the image reconstruction. Resolution losses were compensated for by an iterative algorithm which incorporates a convolution kernel derived from line source measurements for the microPET Focus 120 system. The entire processing chain for these corrections was implemented, whereas previous work has only addressed parts of this process. Monte Carlo simulations with GATE and measurements of mice with the microPET Focus 120 show that the proposed method reduces absolute quantification errors on average to 2.6% compared to 15.6% for the ordinary Maximum Likelihood Expectation Maximization algorithm. Furthermore resolution was improved in the order of 11-29% depending on the number of convolution iterations. In summary, a comprehensive, fast and robust algorithm for the correction of small animal PET studies with I-124 was developed which improves quantitative accuracy and spatial resolution.

  3. Effect of National Football League games on small animal emergency room caseload.

    Science.gov (United States)

    Rozanski, Elizabeth A; Rondeau, Mark P; Shaw, Scott P; Rush, John E

    2009-07-01

    To evaluate whether games of popular professional football teams have an effect on small animal emergency room caseload and percentage of dogs and cats that subsequently are hospitalized, are euthanatized, or die following admission to veterinary emergency rooms located within a dedicated fan base. Prospective study. 818 dogs and cats admitted to the emergency room. During the 2007 New England Patriots (NEP) football season, small animal emergency room caseload was recorded for Sunday (4-hour blocks, 8:00 AM until 12:00 midnight) and Monday night (7:00 PM to 11:00 PM). Number of dogs and cats that subsequently were hospitalized, died, or were euthanatized was recorded. Mean game importance rating (GIR) was determined for NEP games (scale, 1 [mild] to 3 [great]). Percentage of dogs and cats admitted from 12:00 noon to 4:00 PM on Sundays during NEP games (mean GIR, 1.7) versus non-NEP games was not different. Mean +/- SD percentage of dogs and cats admitted from 4:00 PM to 8:00 PM on Sundays during NEP games (mean GIR, 2.4) versus non-NEP games was significantly different (18 +/- 5% and 25 +/- 7% of daily caseload, respectively). Percentage of dogs and cats admitted from 8:00 PM to 12:00 midnight on Sundays during NEP games (mean GIR, 2.1) versus non-NEP games was not different. Game type (NEP vs non-NEP) during emergency room admission did not influence whether dogs and cats subsequently were hospitalized, died, or were euthanatized. Professional sporting events may influence veterinary emergency room caseloads.

  4. Imaging circulating tumor cells in freely moving awake small animals using a miniaturized intravital microscope.

    Directory of Open Access Journals (Sweden)

    Laura Sarah Sasportas

    Full Text Available Metastasis, the cause for 90% of cancer mortality, is a complex and poorly understood process involving the invasion of circulating tumor cells (CTCs into blood vessels. These cells have potential prognostic value as biomarkers for early metastatic risk. But their rarity and the lack of specificity and sensitivity in measuring them render their interrogation by current techniques very challenging. How and when these cells are circulating in the blood, on their way to potentially give rise to metastasis, is a question that remains largely unanswered. In order to provide an insight into this "black box" using non-invasive imaging, we developed a novel miniature intravital microscopy (mIVM strategy capable of real-time long-term monitoring of CTCs in awake small animals. We established an experimental 4T1-GL mouse model of metastatic breast cancer, in which tumor cells express both fluorescent and bioluminescent reporter genes to enable both single cell and whole body tumor imaging. Using mIVM, we monitored blood vessels of different diameters in awake mice in an experimental model of metastasis. Using an in-house software algorithm we developed, we demonstrated in vivo CTC enumeration and computation of CTC trajectory and speed. These data represent the first reported use we know of for a miniature mountable intravital microscopy setup for in vivo imaging of CTCs in awake animals.

  5. "Clean, green and ethical" animal production. Case study: reproductive efficiency in small ruminants.

    Science.gov (United States)

    Martin, Graeme B; Kadokawa, Hiroya

    2006-02-01

    In response to changes in society and thus the marketplace, we need a vision for the future of our animal industries, including both on-farm and off-farm activities, that is "clean, green and ethical". Using small ruminants as a case study, we describe three "clean, green and ethical" strategies that farmers could use to improve reproductive performance. The first allows control of the timing of reproductive events by using socio-sexual signals (the "male effect") to induce synchronised ovulation in females. The second strategy, "focus feeding", is based on using short periods of nutritional supplements that are precisely timed and specifically designed for each event in the reproductive process (eg, gamete production, embryo survival, fetal programming, colostrum production). The third strategy aims to maximize offspring survival by a combination of management, nutrition and genetic selection for behaviour (temperament). All of these approaches involve non-pharmacological manipulation of the endogenous control systems of the animals and complement the detailed information from ultrasound that is now becoming available. Importantly, these approaches all have a solid foundation in reproductive biology. In several cases, they are currently used in commercial practice, but there is still room for improvement through both basic and applied research. Ultimately, these "clean, green and ethical" tools can be cost-effective, increase productivity and, at the same time, greatly improve the image of meat and milk industries in society and the marketplace.

  6. Imaging circulating tumor cells in freely moving awake small animals using a miniaturized intravital microscope.

    Science.gov (United States)

    Sasportas, Laura Sarah; Gambhir, Sanjiv Sam

    2014-01-01

    Metastasis, the cause for 90% of cancer mortality, is a complex and poorly understood process involving the invasion of circulating tumor cells (CTCs) into blood vessels. These cells have potential prognostic value as biomarkers for early metastatic risk. But their rarity and the lack of specificity and sensitivity in measuring them render their interrogation by current techniques very challenging. How and when these cells are circulating in the blood, on their way to potentially give rise to metastasis, is a question that remains largely unanswered. In order to provide an insight into this "black box" using non-invasive imaging, we developed a novel miniature intravital microscopy (mIVM) strategy capable of real-time long-term monitoring of CTCs in awake small animals. We established an experimental 4T1-GL mouse model of metastatic breast cancer, in which tumor cells express both fluorescent and bioluminescent reporter genes to enable both single cell and whole body tumor imaging. Using mIVM, we monitored blood vessels of different diameters in awake mice in an experimental model of metastasis. Using an in-house software algorithm we developed, we demonstrated in vivo CTC enumeration and computation of CTC trajectory and speed. These data represent the first reported use we know of for a miniature mountable intravital microscopy setup for in vivo imaging of CTCs in awake animals.

  7. Monte Carlo dosimetry of iodine contrast objects in a small animal microCT

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Villafuerte, M., E-mail: mercedes@fisica.unam.mx [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico); Martinez-Davalos, A. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 Mexico D.F. (Mexico)

    2011-08-21

    Small animal microcomputed tomography (microCT) studies with iodine-based contrast media are commonly used in preclinical research. While the use of contrast media improves the quality of the images, it can also result in an increase in the absorbed dose to organs with high concentration of the contrast agent, which might cause radiation damage to the animal. In this work we present the results of a Monte Carlo investigation of a microCT dosimetry study using mouse-sized cylindrical water phantoms with iodine contrast insets for different X-ray spectra (Mo and W targets, 30-80 kVp), iodine concentrations (0, 5, 10 and 15 mg mL{sup -1}) and contrast object sizes (3 and 10 mm diameter). Our results indicate an absorbed dose increase in the contrast-inset regions with respect to the absorbed dose distribution within a reference uniform water phantom. The calculated spatial absorbed dose distributions show large gradients due to beam hardening effects, and large absorbed dose enhancement as the mean energy of the beam and iodine concentration increase. We have found that absorbed doses in iodine contrast objects can increase by a factor of up to 12 for a realistic 80 kVp X-ray spectra and an iodine concentration of 15 mg mL{sup -1}.

  8. Wireless Synchronization of a Multi-Pinhole Small Animal SPECT Collimation Device With a Clinical Scanner

    Science.gov (United States)

    DiFilippo, Frank P.; Patel, Sagar

    2009-06-01

    A multi-pinhole collimation device for small animal single photon emission computed tomography (SPECT) uses the gamma camera detectors of a standard clinical SPECT scanner. The collimator and animal bed move independently of the detectors, and therefore their motions must be synchronized. One approach is manual triggering of the SPECT acquisition simultaneously with a programmed motion sequence for the device. However, some data blurring and loss of image quality result, and true electronic synchronization is preferred. An off-the-shelf digital gyroscope with integrated Bluetooth interface provides a wireless solution to device synchronization. The sensor attaches to the SPECT gantry and reports its rotational speed to a notebook computer controlling the device. Software processes the rotation data in real-time, averaging the signal and issuing triggers while compensating for baseline drift. Motion commands are sent to the collimation device with minimal delay, within approximately 0.5 second of the start of SPECT gantry rotation. Test scans of a point source demonstrate an increase in true counts and a reduction in background counts compared to manual synchronization. The wireless rotation sensor provides robust synchronization of the collimation device with the clinical SPECT scanner and enhances image quality.

  9. MOSFET assessment of radiation dose delivered to mice using the Small Animal Radiation Research Platform (SARRP).

    Science.gov (United States)

    Ngwa, Wilfred; Korideck, Houari; Chin, Lee M; Makrigiorgos, G Mike; Berbeco, Ross I

    2011-12-01

    The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites.

  10. Femoral mesenchymal chondrosarcoma with secondary aneurysmal bone cysts mimicking a small-cell osteosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Amukotuwa, Shalini A. [St. Vincent' s Hospital, Melbourne (Australia); Choong, Peter F.M.; Powell, Gerard J. [St. Vincent' s Hospital, Department of Orthopaedics, Melbourne (Australia); Smith, Peter J.; Schlicht, Stephen M. [St. Vincent' s Hospital, Department of Medical Imaging, Melbourne (Australia); Thomas, David [Peter MacCallum Cancer Centre, Ian Potter Centre for Cancer Genomics and Predictive Medicine, Melbourne (Australia)

    2006-05-15

    Mesenchymal chondrosarcoma is a rare but aggressive, high-grade malignancy of primitive cartilage-forming mesenchyme that arises most commonly from skeletal sites. Although there are radiological findings suggestive of the diagnosis, imaging features often overlap with those of other skeletal sarcomas. The definitive diagnosis relies on the histological finding of a typical bimorphic appearance, consisting of nests of small, round, poorly differentiated cells and more mature cartilaginous tissue. To highlight this, we present the case of a 21-year-old man who was referred to our institution with a history of right knee pain. Initial imaging and histological evaluation of a core biopsy of the lesion suggested osteosarcoma of the distal right femur; after review, however, the correct diagnosis of mesenchymal chondrosarcoma was made. Adequate tissue sampling and thorough histological evaluation of biopsy specimens is vital for the accurate diagnosis of primary bone malignancies, especially those of chondroid origin. (orig.)

  11. Comparison of bone age in small-for-gestationalage children vs appropriate-for-getational-age children

    Directory of Open Access Journals (Sweden)

    Lionardus Edward

    2010-04-01

    Full Text Available BackgroundAbout 10-15% small-for-gestational-age children are in higher risk for having linear growth retardation due to growth hormone-insulin like growth factor 1 axis defect (GH-IGF 1 which causes bone age delay.ObjectivesTo compare bone age in 24-36 month old children born small-for-gestational-age (SGA to that in children born appropriate-for-gestational-age (AGA.MethodsA cross-sectional study was conducted in Hasan Sadikin General Hospital, Bandung, from January to April 2009.Subjects consisted of50 healthy children of 24-36 months old (25 children born at term, SGA, 25 children born at term, AGA. We compared the appropriateness and delay of bone age between the two groups. ResultsMean bone age in the SGA group was 20.8 (SD 7.7 months, and in the AGA group was 25.7 (SD 7.1 months (P=0.022. Mean bone age deficit was -10.5 (6.5 months in the SGA group and -5.5 (SD 5.7 months in the AGA group (P=0.009. The prevalence ratio was 1.77 (95% CI: 1.19–2.62. Bone age delay was found to be higher in children born SGA than that in children of the other group (23 vs 13. On the contrary, appropriate bone age was found more in children born AGA (12 vs 2 (P=0.002.Conclusion Bone age delay in 24-36 months old children born small-for-gestational-age was found to be higher than in those born appropriate-for-gestational-age.

  12. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Directory of Open Access Journals (Sweden)

    J. Mejia

    2013-11-01

    Full Text Available The single photon emission microscope (SPEM is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD. Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  13. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    International Nuclear Information System (INIS)

    Mejia, J.; Reis, M.A.; Miranda, A.C.C.; Batista, I.R.; Barboza, M.R.F.; Shih, M.C.; Fu, G.; Chen, C.T.; Meng, L.J.; Bressan, R.A.; Amaro, E. Jr

    2013-01-01

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s -1 ·MBq -1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99m Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99m Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity

  14. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Reis, M.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Miranda, A.C.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Batista, I.R. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Barboza, M.R.F.; Shih, M.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Fu, G. [GE Global Research, Schenectady, NY (United States); Chen, C.T. [Department of Radiology, University of Chicago, Chicago, IL (United States); Meng, L.J. [Department of Nuclear, Plasma and Radiological Engineering, University of Illinois, Urbana-Champaign, IL (United States); Bressan, R.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Amaro, E. Jr [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil)

    2013-11-06

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s{sup -1}·MBq{sup -1} were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging {sup 99m}Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using {sup 99m}Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  15. An application of a new planar positron imaging system (PPIS) in a small animal. MPTP-induced parkinsonism in mouse

    International Nuclear Information System (INIS)

    Takamatsu, Hiroyuki; Noda, Akihiro; Kakiuchi, Takeharu

    2004-01-01

    Recent animal PET research has led to the development of PET scanners for small animals. A planar positron imaging system (PPIS) was newly developed to study physiological function in small animals and plants in recent years. To examine the usefulness of PPIS for functional study in small animals, we examined dopaminergic images of mouse striata in MPTP-induced parkinsonism. Male C57BL/6NCrj mice were treated with MPTP 7 days before the PPIS study. Scans were performed to measure dopamine D 1 receptor binding and dopamine transporter availability with [ 11 C]SCH23390 (about 2 MBq) and [ 11 C]β-CFT (about 2 MBq), respectively. After the PPIS study, dopamine content in the striatum was measured by high-performance liquid chromatography (HPLC). The MPTP treatment significantly reduced dopamine content in the striatum 7 days after treatment. In the MPTP-treated group, [ 11 C]β-CFT binding in the striatum was significantly decreased compared with the control group, while striatal [ 11 C]SCH23390 binding was not affected. Dopamine content in the striatum was significantly correlated with the striatal binding of [ 11 C]β-CFT. The present results suggest that PPIS is able to determine brain function in a small animal. Using PPIS, high throughput imaging of small animal brain functions could be achieved. (author)

  16. How does iliac crest bone marrow biopsy compare with imaging in the detection of bone metastases in small cell lung cancer?

    International Nuclear Information System (INIS)

    Perrin-Resche, I.; Bizais, Y.; Buhe, T.; Fiche, M.

    1993-01-01

    Iliac crest bone marrow biopsy (BMB) has often been used as the gold standard for the detection of bone marrow metastases in small cell lung cancer (SCLC). However, it is likely to lead to numerous false-negative results. For this reason, we compared the results of bone scintigraphy (BS), magnetic resonance imaging (MRI), and BMB in 48 sequential patients affected with pathologically confirmed SCLC (47 were evaluable; mean age, 58.4 years). The three procedures were carried out within 1 week, no treatment being performed during this period. Whole-body scans and spot views were obtained in the anterior and posterior projections. For MRI, only the thoracolumbar spine, the sternum and the pelvis were scanned, using spin-echo T1-weighted sequences, resulting in an acquisition time of less than 45 min. Only five BMBs were rated as positive. In these cases, both BS and MRI were also positive. The other 42 biopsies were negative. Among them, in ten cases both BS and MRI were positive. In 21 cases, both BS and MRI were negative. In five cases MRI was positive while BS was negative. Finally, in six cases MRI was negative whilst BS was positive. In most cases in which either BS or MRI was positive, follow-up scans confirmed the initial findings. This study suggests that BMB is more invasive and less sensitive than BS or MRI in detecting bone metastases. MRI seems to be more sensitive than BS in detecting small spinal or pelvic metastases. Whole-body bone scintigraphy is more sensitive in detecting skull, costal or peripheral metastases. BS and MRI should be used in combination and may replace BMB in the detection of bone metastases in SCLC. (orig.)

  17. 78 FR 59624 - Guidance for Industry #223: Small Entity Compliance Guide-Declaring Color Additives in Animal...

    Science.gov (United States)

    2013-09-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 501 [Docket No. FDA-2013-D-1088] Guidance for Industry 223: Small Entity Compliance Guide--Declaring Color Additives... industry 223 entitled ``Small Entity Compliance Guide--Declaring Color Additives in Animal Foods.'' This...

  18. Comparative characteristics of shoulder blade (Scapula and shoulder bone (Humerus of roe deer (Capreolus capreolus and sheep (Ovis aries in order to determine the animal species

    Directory of Open Access Journals (Sweden)

    Blagojević Miloš

    2016-01-01

    Full Text Available In illegal hunting it is often possible only on the basis of morphological characteristics to determine the animal species. By the method of comparison there was performed the forensic analysis of roe deer and sheep osteological features. For the purpose of investigating the shoulder blade (Scapula and shoulder bone (Humerus comparative characteristics, there were used 6 shoulder blades and 6 shoulder bones of roe deer and 8 shoulder blades and 8 shoulder bones of sheep. After the skin, muscles, arterial, venous and lymphatic vessels as well as nerves were removed from the bones, they were thermally treated in an autoclave. Subsequently, the bones were placed in 3% solutioin of hydrogen peroxide (H2O2 for bleaching and degreasing. Then they were air dried and then photographed. Shoulder blade (Scapula is a bone plate (Ossa plana roughly triangular in shape. Scapular spine (Spina scapulae is much more prominent in roe deer with acromion blade in the form of spike, while in sheep it is shorter and ends with acrimion at a right angle. Shoulder blade cup (Cavitas glenoidalis in roe deer is round in shape, and in sheep it is oval. Tuberculum supraglenoidale and Processus coracoideus in sheep are more and in roe deer less developed. Shoulder bone (Humerus in roe deer is relatively long, slender bone with proximal convexity turned cranially in regard to the same bone in sheep, which is stronger and heavier. Tuberculum majus in roe deer is less developed, and in sheep it is in a form of solid bone protuberance. Tuberculum minus and Tuberositas deltoidea in sheep are more developed than in roe deer. At medial condyle (Condylus medialis in sheep there is shallow and wide groove, while in roe deer it is deeper and narrower. On the basis of morphological differences of roe deer and sheep bones, it can be determined with certainty which animal spesies they belong to.

  19. Reflections upon the trends of education and research in small animal reproduction in Europe.

    Science.gov (United States)

    Rodríguez-Martínez, Heriberto

    2004-01-01

    An open questionnaire-based survey was performed among 86 institutions of veterinary education in 32 European countries: 15 within the European Union (EU) and 17 outside the EU, in Central and Eastern Europe and the European Free Trade Association (EFTA). The survey aimed to provide a view of the general status of education and research in small animal reproduction (SAR) in Europe. It further aimed to disclose whether ongoing trends in organization (e.g., from the classical animal reproduction discipline orientation [DO] toward a species-oriented [SO] organization) among veterinary colleges responsible for undergraduate education and research in SAR have affected the provision of clinical services, continuing professional development (CPD), specialization, post-graduate education, and research. Response rates reached 80% among EU institutions and 48.4% in other countries (overall response rate = 68.6%). A clear, significant majority of institutions (> 60%) were DO, with a well-defined comparative subject in the veterinary curriculum. No differences were reported for either orientation in their ability to provide undergraduate education or clinical services in SAR. However, more DO institutions reported active research in SAR than their SO counterparts. Similar (and stronger) differences were seen for post-graduate education, CPD, and participation in specialization programs (national or European). Finally, more DO than SO institutions provided assisted reproductive technologies (ARTs), such as AI with frozen semen, to customers. The analysis of the data emanating from the respondents' perceptions, supports the advantages of the more classical, DO-based approach. The results highlight the need for caution when institutions abandon the comparative benefits of the classical DO animal reproduction subject for a SO approach, which tends to prioritize clinical specialized service rather than research and research education. In the author's opinion, in the absence of the

  20. Multi-modality image reconstruction for dual-head small-animal PET

    International Nuclear Information System (INIS)

    Huang, Chang-Han; Chou, Cheng-Ying

    2015-01-01

    The hybrid positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI) has become routine practice in clinics. The applications of multi-modality imaging can also benefit research advances. Consequently, dedicated small-imaging system like dual-head small-animal PET (DHAPET) that possesses the advantages of high detection sensitivity and high resolution can exploit the structural information from CT or MRI. It should be noted that the special detector arrangement in DHAPET leads to severe data truncation, thereby degrading the image quality. We proposed to take advantage of anatomical priors and total variation (TV) minimization methods to reconstruct PET activity distribution form incomplete measurement data. The objective is to solve the penalized least-squares function consisted of data fidelity term, TV norm and medium root priors. In this work, we employed the splitting-based fast iterative shrinkage/thresholding algorithm to split smooth and non-smooth functions in the convex optimization problems. Our simulations studies validated that the images reconstructed by use of the proposed method can outperform those obtained by use of conventional expectation maximization algorithms or that without considering the anatomical prior information. Additionally, the convergence rate is also accelerated.

  1. Uranium in fossil bones

    International Nuclear Information System (INIS)

    Koul, S.L.

    1978-01-01

    An attempt has been made to determine the uranium content and thus the age of certain fossil bones Haritalyangarh (Himachal Pradesh), India. The results indicate that bones rich in apatite are also rich in uranium, and that the radioactivity is due to radionuclides in the uranium series. The larger animals apparently have a higher concentration of uranium than the small. The dating of a fossil jaw (elephant) places it in the Pleistocene. (Auth.)

  2. Comparative characteristics of shoulder blade (Scapula) and shoulder bone (Humerus) of roe deer (Capreolus capreolus) and sheep (Ovis aries) in order to determine the animal species

    OpenAIRE

    Blagojević Miloš; Nikolić Zora; Prokić Bogomir Bolka; Ćupić-Miladinović Dejana

    2016-01-01

    In illegal hunting it is often possible only on the basis of morphological characteristics to determine the animal species. By the method of comparison there was performed the forensic analysis of roe deer and sheep osteological features. For the purpose of investigating the shoulder blade (Scapula) and shoulder bone (Humerus) comparative characteristics, there were used 6 shoulder blades and 6 shoulder bones of roe deer and 8 shoulder blades and 8 shoulder...

  3. Bone response to hydroxyapatites with open porosity of animal origin (porcine [OsteoBiol mp3] and bovine [Endobon]): a radiological and histomorphometric study.

    Science.gov (United States)

    Ramírez-Fernández, MaPiedad; Calvo-Guirado, Jose Luis; Delgado-Ruiz, Rafael Arcesio; Maté-Sánchez Del Val, José Eduardo; Vicente-Ortega, Vicente; Meseguer-Olmos, Luis

    2011-07-01

    To carry out a radiological and histomorphometric evaluation of bone response to two xenografts of animal origin, one porcine, and the other bovine, inserted in rabbits' tibiae. Twenty New Zealand rabbits weighing 3900-4500 g were used. Twenty bovine bone grafts (Endobon) in granulated form of 500-1000 μm granulometry were inserted in the proximal metaphyseal area of the animals' right tibia, and 20 porcine bone grafts (OsteoBiol mp3) in granulated form of 600-1000 μm granulometry were inserted in the proximal metaphyseal area of the animals' left tibia. Following graft insertion, the animals were sacrificed in four groups of five, after 1, 2, 3 and 4 months, respectively. Anteroposterior and lateral radiographs were taken. Samples were processed for observation under light microscopy. Histomorphometric measurements were presented as mean values ± standard deviations. At 4 months after treatment, the bone defects displayed radiological images that showed complete repair of osseous defects. Histomorphometric evaluation showed that for the porcine xenograft, the study averages for newly formed bone represented 22.8 ± 1.8%, for residual graft material 23.6 ± 3% and for connective tissue 53.5 ± 2.5%, while for the bovine xenograft newly formed bone represented 23.1 ± 1.8%, residual graft material 39.4 ± 3% and non-mineralized connective tissue 37.5 ± 2.5%. The biomaterials assessed in the study were shown to be biocompatible and osteoconductive. Collagenized porcine xenografts proved more resorbable than bovine xenografts. Both can be used as possible bone substitutes without interfering with normal reparative bone processes. © 2011 John Wiley & Sons A/S.

  4. The Stable Isotopes of Carbon and Nitrogen in the Bones of Domestic Animals from three Cities of the European Part of Russia: First Results and Interpretations

    Directory of Open Access Journals (Sweden)

    Yavorskaya Liliya Vyacheslavovna

    2015-03-01

    Full Text Available The paper outlines the results of first purposeful research on isotopic composition (carbon 13С and nitrogen 15N in the bones collagen of domestic and wild animals from medieval towns at the European part of Russia. The published information about δ 13С и δ 15N was obtained from 61 samples of osteological collections of Yaroslavl, Rostov and Bolgar. The average values of carbon isotope in cattle bones are almost the same in all three cities. By contrast, these values for horses and pigs from Rostov and Bolgar are higher than for Yaroslavl animals. Unusual similarity for δ13С in the bones of sheep, camels and dogs among themselves from the Bolgar collection were fixed. The comparative analysis of the values δ13С in bones of domestic and wild animals allowed us to propose the hypothesis that sheep, camels and dogs appeared in Bolgar from the southern arid areas. The data on δ15N showed the inexplicably high accumulation of the nitrogen stable isotope in sheep and camel bones from the collection of Bolgar and in beaver bones from Rostov samples. This is probably due to the peculiarities of the diet of these dogs, enriched by the entrails of domestic ungulates or fish. The minimum values of δ15N in the bones of dogs from Bolgar reflect the specific diet of herding dogs with a minimal volume of meat. Simultaneously the data of 15N in sheep and camel bones from Bolgar collection and in beaver bones from Rostov samples howed the inexplicably high level of nitrogen stable isotope accumulation.

  5. Locally delivered ethyl-2,5-dihydroxybenzoate using 3D printed bone implant for promotion of bone regeneration in a osteoporotic animal model

    Directory of Open Access Journals (Sweden)

    B-J Kwon

    2018-01-01

    Full Text Available Osteoporosis is a disease characterized by low bone mass, most commonly caused by an increase in bone resorption that is not matched by sufficient bone formation. The most common complications of postmenopausal osteoporosis are bone-related defects and fractures. Fracture healing is a multifactorial bone regeneration process, influenced by both biological and mechanical factors related to age, osteoporosis and stability of the osteosynthesis. During the treatment of bone defects in osteoporotic conditions, imbalanced bone remodeling is the leading cause for implant failure. To overcome these problems, ethyl-2,5-dihydroxybenzoate (E-2,5-DHB, a drug that promotes bone formation and inhibits bone resorption, was used. E-2,5-DHB-incorporating titanium (Ti implants using poly(lactic-co-glycolic acid (PLGA coating for local delivery of E-2,5-DHB were developed and the effects on bone healing of femoral defects were evaluated in an osteoporotic model. The release of E-2,5-DHB resulted in decreased bone resorption and increased bone formation around the implant. Thus, it was confirmed that, in the osteoporotic model, bone healing was increased and implant fixation was enhanced. These results suggested that E-2,5-DHB-coated Ti implants have great potential as an ultimate local drug delivery system for bone tissue scaffolds.

  6. Microbiological Standardization in Small Laboratory Animals and Recommendations for the Monitoring

    OpenAIRE

    Meral Karaman

    2014-01-01

    Microbiological standardization in laboratory animal breeding is based on the classification according to the microorganisms that the animals host and consequently their upbringing environment, as well as the certification of their microbiological status and the protection of their properties. Although there are many different classifications for microbiological standardization of laboratory animals, they can be basically classified as; gnotobiotic animals, animals bred with a complete barrie...

  7. Scintigraphic control of bone-fracture healing under ultrasonic stimulation: An animal experimental study

    International Nuclear Information System (INIS)

    Klug, W.; Franke, W.G.; Knoch, H.G.

    1986-01-01

    In a model of closed lower-leg fracture in rabbits and of secondary bone-fracture healing, scintigraphic control until biological healing was performed. Biological fracture healing was assumed for a region of interest (ROI)-activity ratio close to 1.0. After application of sup(99m)Tc-HEDP, 151 examinations were performed. ROI activity increased significantly until day 14 p.i. and reached the maximum value (Q=6.44) on day 14 postfracture. Sixty-one lower leg fractures were treated by ultrasound from days 14-28 postfractures. These stimulated fractures were biologically healed on day 168 postfracture. The fractures that were not treated by ultrasound could not be detected by scanning after day 203 postfracture. (orig.)

  8. Mechanistic models of bone cancer induction by radium and plutonium in animals compared to humans

    International Nuclear Information System (INIS)

    Bijwaard, H.

    2006-01-01

    Two-mutation carcinogenesis models of mice and rats injected with 239 Pu and 226 Ra have been derived extending previous modellings of beagle dogs injected with 239 Pu and 226 Ra and radium dial painters. In all cases statistically significant parameters could be derived fitting data from several research groups jointly. This also lead to similarly parametrized models for 239 Pu and 226 Ra for all species. For each data set not more than five free model parameters were needed to fit the data adequately. From the toxicity ratios of the animal models for 239 Pu and 226 Ra, together with the human model for 226 Ra, an approximate model for the exposure of humans to 239 Pu has been derived. Relative risk calculations with this approximate model are in good agreement with epidemiological findings for the plutonium-exposed Mayak workers. This promising result may indicate new possibilities for estimating risks for humans from animal experiments. (authors)

  9. Comparative evaluation of hydroxyapatite and nano-bioglass in two forms of conventional micro- and nano-particles in repairing bone defects (an animal study).

    Science.gov (United States)

    Nosouhian, Saied; Razavi, Mohammad; Jafari-Pozve, Nasim; Rismanchian, Mansour

    2015-01-01

    Many synthetic bone materials have been introduced for repairing bone defects. The aim of this study is to comparatively evaluate the efficacy of nano-hydroxyapatite (HA) and nano-bioglass bone materials with their traditional micro counterparts in repairing bone defects. In this prospective animal study, four healthy dogs were included. First to fourth premolars were extracted in each quadrant and five cavities in each quadrant were created using trephine. Sixteen cavities in each dog were filled by HA, nano-HA, bioglass, and nano-bioglass and four defects were left as the control group. All defects were covered by a nonrestorable membrane. Dogs were sacrificed after 15, 30, 45, and 60 days sequentially. All 20 samples were extracted by trephine #8 with a sufficient amount of surrounding bone. All specimens were investigated under an optical microscope and the percentage of total regenerated bone, lamellar, and woven bone were evaluated. Data analysis was carried out by SPSS Software ver. 15 and Mann-Whitney U-test (α =0.05). After 15 days, the bone formation percentage showed a significant difference between HA and nano-HA and between HA and bioglass (P bone formation after 15 days. Nano-bioglass and bioglass and nano-HA and nano-bioglass groups represented a significant difference and nano-bioglass showed the highest rate of bone formation after 30 days (P = 0.01). After 45 days, the bone formation percentage showed a significant difference between nano-bioglass and bioglass and between nano-HA and nano-bioglass groups (P = 0.01). Nano-HA and nano-bioglass biomaterials showed promising results when compared to conventional micro-particles in the repair of bone defects.

  10. Bat-mouse bone marrow chimera: a novel animal model for dissecting the uniqueness of the bat immune system.

    Science.gov (United States)

    Yong, Kylie Su Mei; Ng, Justin Han Jia; Her, Zhisheng; Hey, Ying Ying; Tan, Sue Yee; Tan, Wilson Wei Sheng; Irac, Sergio Erdal; Liu, Min; Chan, Xue Ying; Gunawan, Merry; Foo, Randy Jee Hiang; Low, Dolyce Hong Wen; Mendenhall, Ian Hewitt; Chionh, Yok Teng; Dutertre, Charles-Antoine; Chen, Qingfeng; Wang, Lin-Fa

    2018-03-16

    Bats are an important animal model with long lifespans, low incidences of tumorigenesis and an ability to asymptomatically harbour pathogens. Currently, in vivo studies of bats are hampered due to their low reproduction rates. To overcome this, we transplanted bat cells from bone marrow (BM) and spleen into an immunodeficient mouse strain NOD-scid IL-2R -/- (NSG), and have successfully established stable, long-term reconstitution of bat immune cells in mice (bat-mice). Immune functionality of our bat-mouse model was demonstrated through generation of antigen-specific antibody response by bat cells following immunization. Post-engraftment of total bat BM cells and splenocytes, bat immune cells survived, expanded and repopulated the mouse without any observable clinical abnormalities. Utilizing bat's remarkable immunological functions, this novel model has a potential to be transformed into a powerful platform for basic and translational research.

  11. Low relative error in consumer-grade GPS units make them ideal for measuring small-scale animal movement patterns

    Directory of Open Access Journals (Sweden)

    Greg A. Breed

    2015-08-01

    Full Text Available Consumer-grade GPS units are a staple of modern field ecology, but the relatively large error radii reported by manufacturers (up to 10 m ostensibly precludes their utility in measuring fine-scale movement of small animals such as insects. Here we demonstrate that for data collected at fine spatio-temporal scales, these devices can produce exceptionally accurate data on step-length and movement patterns of small animals. With an understanding of the properties of GPS error and how it arises, it is possible, using a simple field protocol, to use consumer grade GPS units to collect step-length data for the movement of small animals that introduces a median error as small as 11 cm. These small error rates were measured in controlled observations of real butterfly movement. Similar conclusions were reached using a ground-truth test track prepared with a field tape and compass and subsequently measured 20 times using the same methodology as the butterfly tracking. Median error in the ground-truth track was slightly higher than the field data, mostly between 20 and 30 cm, but even for the smallest ground-truth step (70 cm, this is still a signal-to-noise ratio of 3:1, and for steps of 3 m or more, the ratio is greater than 10:1. Such small errors relative to the movements being measured make these inexpensive units useful for measuring insect and other small animal movements on small to intermediate scales with budgets orders of magnitude lower than survey-grade units used in past studies. As an additional advantage, these units are simpler to operate, and insect or other small animal trackways can be collected more quickly than either survey-grade units or more traditional ruler/gird approaches.

  12. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV)

    International Nuclear Information System (INIS)

    Qian Ming; Niu Lili; Jiang Bo; Jin Qiaofeng; Jiang Chunxiang; Zheng Hairong; Wang Yanping

    2010-01-01

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  13. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    Science.gov (United States)

    Qian, Ming; Niu, Lili; Wang, Yanping; Jiang, Bo; Jin, Qiaofeng; Jiang, Chunxiang; Zheng, Hairong

    2010-10-21

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  14. Improvement of semi-quantitative small-animal PET data with recovery coefficients: a phantom and rat study.

    Science.gov (United States)

    Aide, Nicolas; Louis, Marie-Hélène; Dutoit, Soizic; Labiche, Alexandre; Lemoisson, Edwige; Briand, Mélanie; Nataf, Valérie; Poulain, Laurent; Gauduchon, Pascal; Talbot, Jean-Noël; Montravers, Françoise

    2007-10-01

    To evaluate the accuracy of semi-quantitative small-animal PET data, uncorrected for attenuation, and then of the same semi-quantitative data corrected by means of recovery coefficients (RCs) based on phantom studies. A phantom containing six fillable spheres (diameter range: 4.4-14 mm) was filled with an 18F-FDG solution (spheres/background activity=10.1, 5.1 and 2.5). RCs, defined as measured activity/expected activity, were calculated. Nude rats harbouring tumours (n=50) were imaged after injection of 18F-FDG and sacrificed. The standardized uptake value (SUV) in tumours was determined with small-animal PET and compared to ex-vivo counting (ex-vivo SUV). Small-animal PET SUVs were corrected with RCs based on the greatest tumour diameter. Tumour proliferation was assessed with cyclin A immunostaining and correlated to the SUV. RCs ranged from 0.33 for the smallest sphere to 0.72 for the largest. A sigmoidal correlation was found between RCs and sphere diameters (r(2)=0.99). Small-animal PET SUVs were well correlated with ex-vivo SUVs (y=0.48x-0.2; r(2)=0.71) and the use of RCs based on the greatest tumour diameter significantly improved regression (y=0.84x-0.81; r(2)=0.77), except for tumours with important necrosis. Similar results were obtained without sacrificing animals, by using PET images to estimate tumour dimensions. RC-based corrections improved correlation between small-animal PET SUVs and tumour proliferation (uncorrected data: Rho=0.79; corrected data: Rho=0.83). Recovery correction significantly improves both accuracy of small-animal PET semi-quantitative data in rat studies and their correlation with tumour proliferation, except for largely necrotic tumours.

  15. Method to reduce non-specific tissue heating of small animals in solenoid coils.

    Science.gov (United States)

    Kumar, Ananda; Attaluri, Anilchandra; Mallipudi, Rajiv; Cornejo, Christine; Bordelon, David; Armour, Michael; Morua, Katherine; Deweese, Theodore L; Ivkov, Robert

    2013-01-01

    Solenoid coils that generate time-varying or alternating magnetic fields (AMFs) are used in biomedical devices for research, imaging and therapy. Interactions of AMF and tissue produce eddy currents that deposit power within tissue, thus limiting effectiveness and safety. We aim to develop methods that minimise excess heating of mice exposed to AMFs for cancer therapy experiments. Numerical and experimental data were obtained to characterise thermal management properties of water using a continuous, custom water jacket in a four-turn simple solenoid. Theoretical data were obtained with method-of-moments (MoM) numerical field calculations and finite element method (FEM) thermal simulations. Experimental data were obtained from gel phantoms and mice exposed to AMFs having amplitude >50 kA/m and frequency of 160 kHz. Water has a high specific heat and thermal conductivity, is diamagnetic, polar, and nearly transparent to magnetic fields. We report at least a two-fold reduction of temperature increase from gel phantom and animal models when a continuous layer of circulating water was placed between the sample and solenoid, compared with no water. Thermal simulations indicate the superior efficiency in thermal management by the developed continuous single chamber cooling system over a double chamber non-continuous system. Further reductions of heating were obtained by regulating water temperature and flow for active cooling. These results demonstrate the potential value of a contiguous layer of circulating water to permit sustained exposure to high intensity alternating magnetic fields at this frequency for research using small animal models exposed to AMFs.

  16. Perceptions and opinions of Canadian pet owners about anaesthesia, pain and surgery in small animals.

    Science.gov (United States)

    Steagall, P V; Monteiro, B P; Ruel, H L M; Beauchamp, G; Luca, G; Berry, J; Little, S; Stiles, E; Hamilton, S; Pang, D

    2017-07-01

    The aim of this study was to evaluate the perceptions and opinions of Canadian pet owners about anaesthesia, pain and surgery in dogs and cats. Six Canadian veterinary hospitals participated. Each practice received 200 copies of a questionnaire that were distributed to pet owners. Questions regarding the use of analgesics, anaesthesia, surgery and onychectomy (cats) were included. Responses were transformed into ordinal scores and analysed with a Cochran-Mantel-Haenszel test. A total of 849 out of 1200 questionnaires were returned. Owners believed more frequently that analgesics are needed for surgical procedures than for the medical conditions. Owners rated as very important/important: "knowing what to expect during illness/injury/surgery" (99·3%), "being assured that all necessary analgesic drugs/techniques will be used" (98·6%), "being informed about procedures/risk" (98·5%), and having a board-certified anaesthesiologist (90·5%). Most owners agreed/partly agreed that pain impacts quality of life (94·2%), and affects their pet's behaviour (89·5%). Most respondents (69%) were women; they were significantly more concerned than men about anaesthesia, pain, cost and client-communication. Cat owners believed that analgesics were necessary for some procedures/conditions significantly more often than canine-only owners. Pet owners with previous surgery disagreed more frequently that "pain after surgery can be helpful" and that "pain in animals is easy to recognize" than those without previous surgery. Most owners think onychectomy should be banned in cats (56·4%). This study identified important areas of client communication regarding pain and its control in pets. © 2017 British Small Animal Veterinary Association.

  17. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence.

    Science.gov (United States)

    Buddhachat, Kittisak; Klinhom, Sarisa; Siengdee, Puntita; Brown, Janine L; Nomsiri, Raksiri; Kaewmong, Patcharaporn; Thitaram, Chatchote; Mahakkanukrauh, Pasuk; Nganvongpanit, Korakot

    2016-01-01

    Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae), antler (Cervidae), teeth and bone (humerus) across a number of species determined by handheld X-ray fluorescence (XRF) to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe) in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application.

  18. An approximation of tribological behavior of Ti1-xAlxN coatings against animal bone in ringers solution

    International Nuclear Information System (INIS)

    Esguerra A, A.; Arteaga, N. A.; Ipaz, L.; Aguilar, Y.; Amaya, C.; Alba de Sanchez, N.

    2014-01-01

    Due to their excellent properties, Ti-Al-N coatings have become attractive for biomedical applications. In this paper, friction and wear properties of Ti 1-x Al x N films having various aluminum contents, x, have been studied. Adhesion was measured by the scratch test technique; friction was carried out by a pin-on-disk tribometer using an animal bone-pin as counterpart and Ringer solution as simulated body fluid; and wear mechanisms were identified by scanning electron microscopy and Energy Dispersive X-ray Spectroscopy (EDS). It was found that the coating with x = 0.41 exhibited the highest CO F, conserves its integrity as a coating, and causes the lowest wear on the bone in Ringers solution. EDS analysis was performed to determine the contents of Ti, Al and N. An X-ray diffraction study was carried out using and X pert High Score Plus diffractometer with Cu-Kα radiation (α = 1.5406 A) at grazing angle of 0.5 grades. (Author)

  19. Small-area analyses of bone cancer diagnosed in Great Britain provide clues to aetiology

    Directory of Open Access Journals (Sweden)

    McNally Richard J Q

    2012-06-01

    Full Text Available Abstract Background The aetiology of bone cancers is poorly understood. This study examined geographical patterning in incidence of primary bone cancers diagnosed in 0–49 year olds in Great Britain during 1980–2005 to provide information on factors linked with disease development. We investigated putative associations with deprivation and population density. Methods Data on osteosarcoma and Ewing sarcoma were obtained from national population-based registries. Negative binomial regression was used to examine the relationship between incidence rates and the Townsend deprivation score (and its component variables and small-area population density. Results The study analyzed 2566 osteosarcoma and 1650 Ewing sarcoma cases. For females with osteosarcoma, statistically significant decreased risk was associated with higher levels of deprivation (relative risk [RR] per unit increase in deprivation score = 0.969; 95% confidence interval [CI] 0.946–0.993. For all Ewing sarcoma combined, statistically significant decreased risk was associated with greater area-level population density and higher levels of non-car ownership (RR per person per hectare increase = 0.984; 95% CI 0.976–0.993, RR per 1% increase in non-car ownership = 0.994; 95% CI 0.991–0.998. Conclusions Higher incidence of osteosarcoma was observed for females in areas with lower deprivation levels indicating increased risk is linked to some aspect of affluent living. Higher incidence of Ewing sarcoma occurred in areas of low population density and where more people owned cars, both characteristic of rural environments. The study adds substantially to evidence associating Ewing sarcoma risk with rural environmental exposures. Putative risk factors include agricultural exposures, such as pesticides and zoonotic agents.

  20. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn J., E-mail: frohwein@uni-muenster.de; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Hoerr, Verena; Faber, Cornelius [Department of Clinical Radiology, University Hospital of Münster, Münster 48149 (Germany)

    2015-07-15

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  1. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn J.; Schäfers, Klaus P.; Hoerr, Verena; Faber, Cornelius

    2015-01-01

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  2. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  3. Microbiological Standardization in Small Laboratory Animals and Recommendations for the Monitoring

    Directory of Open Access Journals (Sweden)

    Meral Karaman

    2014-03-01

    Full Text Available Microbiological standardization in laboratory animal breeding is based on the classification according to the microorganisms that the animals host and consequently their upbringing environment, as well as the certification of their microbiological status and the protection of their properties. Although there are many different classifications for microbiological standardization of laboratory animals, they can be basically classified as; gnotobiotic animals, animals bred with a complete barrier system (Germ free, GF, with Colonization-Resistant Flora; CRF, animals bred with a partial barrier system (Specified Pathogen Free, SPF, and animals bred by conventional methods in units without barriers (Conventional; CV. Monitoring of microbiological standardization is carried out in two ways. One is controlling barrier systems (process control and the other is controlling laboratory animals (product control. In controlling barrier systems samples are taken routinely from ambient air, surfaces, base plate materials of animals, foods and waters, and microbiological tests are carried out. FELASA guidelines are frequently used in monitoring laboratory animals. These guidelines where the monitoring frequency, sample size, micro-organisms to be tested, vary according to the microbiological quality of the animals, and test methods and are frequently updated by FELASA and shared in their web pages. In our country, in general, laboratory animals used for experimental studies present no microbiological standardization, and follow-up protocols are not implemented. Therefore, construction of facilities for the production of microbiologically standard animals and establishment of backup laboratories testing microbiological quality should be established.

  4. Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Choi, Yong; Cho, Gyuseong; Choe, Yearn Seong; Lee, Kyung-Han; Kim, Byung-Tae

    2004-01-01

    A positron emission tomograph dedicated to small animal imaging should have high spatial resolution and sensitivity, and dual layer scintillators have been developed for this purpose. In this study, simulations were performed to optimize the order and the length of each crystal of a dual layer phoswich detector, and to evaluate the possibility of measuring signals from each layer of the phoswich detector. A simulation tool GATE was used to estimate the sensitivity and resolution of a small PET scanner. The proposed scanner is based on dual layer phoswich detector modules arranged in a ring of 10 cm diameter. Each module is composed of 8 x 8 arrays of phoswich detectors consisting of LSO and LuYAP with a 2 mm x 2 mm sensitive area coupled to a Hamamatsu R7600-00-M64 PSPMT. The length of the front layer of the phoswich detector varied from 0 to 10 mm at 1 mm intervals, and the total length (LSO + LuYAP) was fixed at 20 mm. The order of the crystal layers of the phoswich detector was also changed. Radial resolutions were kept below 3.4 mm and 3.7 mm over 8 cm FOV, and sensitivities were 7.4% and 8.0% for LSO 5 mm-LuYAP 15 mm, and LuYAP 6 mm-LSO 14 mm phoswich detectors, respectively. Whereas, high and uniform resolutions were achieved by using the LSO front layer, higher sensitivities were obtained by changing the crystal order. The feasibilities for applying crystal identification methods to phoswich detectors consisting of LSO and LuYAP were investigated using simulation and experimentally derived measurements of the light outputs from each layer of the phoswich detector. In this study, the optimal order and lengths of the dual layer phoswich detector were derived in order to achieve high sensitivity and high and uniform radial resolution

  5. Endoscopic Cerenkov luminescence imaging: in vivo small animal tumor model validation

    Science.gov (United States)

    Song, Tianming; Bao, Chengpeng; Hu, Zhenhua; Wang, Kun; Liu, Xia; Tian, Jie

    2015-03-01

    Background: Cerenkov luminescence imaging (CLI) provides a great potential for clinical translation of optical molecular imaging techniques through using clinical approved radiotracers. However, it is difficult to obtain the Cerenkov luminescence signal of deeper biological tissues due to the small magnitude of the signal. To efficiently acquire the weak Cerenkov luminescence, we developed an endoscopic Cerenkov luminescence imaging (ECLI) system to reduce the in vivo imaging depth with minimum invasion, and validated the system on small animal tumor models. Methods: For the ECLI system, the laparoscope was connected to a high sensitive charge-couple device (CCD) camera (DU888+, Andor, UK) by a custom made adapter. We conducted a series of in vitro and in vivo experiments by use of the system. In the in vitro experiment, the endoscopic luminescence images of the 18F-FDG with various activities in EP tubes were acquired using ECLI system, and the sensitivity was compared with conventional CLI system. In the in vivo tumor experiment, 18F-FDG with the activity of 200μCi were intravenously injected into 3 tumor mice. Then the ECLI system was used to acquire the optical images for both non-invasive and invasive conditions. Conclusion: Experimental data showed the ECLI system could detect the 18F-FDG with the activity as low as 1μCi. Furthermore, our preliminary results indicated the possibility of ECLI technique for detecting Cerenkov signals inside the tumor tissue with deeper depth and guiding the surgical operation of tumor excision. We believe that this technique can help to accelerate the clinical translation of CLI.

  6. Development of computational small animal models and their applications in preclinical imaging and therapy research

    NARCIS (Netherlands)

    Xie, Tianwu; Zaidi, Habib

    The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal

  7. Alteration of cancer pain-related signals by radiation: Proteomic analysis in an animal model with cancer bone invasion

    International Nuclear Information System (INIS)

    Park, Hee Chul; Seong, Jinsil; An, Jung Hee; Kim, Jiyoung; Kim, Un Jung; Lee, Bae Whan

    2005-01-01

    Purpose: Although radiotherapy is highly effective in relieving bone pain due to cancer invasion, its mechanism remains unclear. The aim of this study was to explore this mechanism in an animal model system. Methods and Materials: A hind paw model of cancer pain was developed by transplanting a murine hepatocarcinoma, HCa-1, into the periosteal membrane of the foot dorsum of C3H/HeJ mice. Bone invasion from HCa-1 was histopathologically confirmed from sequential tumor sampling. For three experimental groups, a control (N), tumor without radiation (T), and tumor with radiation (TR), the development and level of pain were objectively examined in mice with a growing tumor by assessing pain-associated behavior. The differential expression of pain-related signals in the spinal cord was analyzed by proteomic analysis using high-resolution two-dimensional gel electrophoresis (2-DE) and mass spectrometry, and those of proteins by Western blotting. The pain-mediating neurotransmitters in the spinal cord were also examined by immunohistochemical staining for calcitonin gene-related peptide (CGRP) and substance P. Results: In the histopathologic examinations, bone invasion from HCa-1 was seen from Day 7 and was evident at Day 14 after transplantation, and measurable pain-associated behaviors were developed from Day 7. After 25 Gy of radiation to the tumors, the objective level of pain in the TR group decreased, with higher thresholds to mechanical and thermal stimulation than in the T group. From the 2-DE of spinal cord, 107 spots were identified; 12 proteins were changed more than fivefold because of tumor formation but then reversed after radiation in the tumor-bearing mice. The proteins involved included secretagogin, syntenin, P2X purinoreceptor 6 (P2X6), and Ca 2+ /Calmodulin-dependent protein kinase 1 (CaM kinase 1), the functions of which have been known to be involved in the Ca 2+ -signaling cascade, ATP-mediated fast synaptic transmission, or control of vesicular

  8. Alteration of cancer pain-related signals by radiation: Proteomic analysis in an animal model with cancer bone invasion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Chul [Department of Radiation Oncology, Hallym University, Chuncheon (Korea, Republic of); Seong, Jinsil [Department of Radiation Oncology, Brain Korea 21 Project for Medicine, Yonsei University, Seoul (Korea, Republic of); An, Jung Hee [Department of Radiation Oncology, Brain Korea 21 Project for Medicine, Yonsei University, Seoul (Korea, Republic of); Kim, Jiyoung [Department of Radiation Oncology, Brain Korea 21 Project for Medicine, Yonsei University, Seoul (Korea, Republic of); Kim, Un Jung [Yonsei Medical Research Center, Brain Korea 21 Project for Medicine, Yonsei University, Seoul (Korea, Republic of); Lee, Bae Whan [Yonsei Medical Research Center, Brain Korea 21 Project for Medicine, Yonsei University, Seoul (Korea, Republic of)

    2005-04-01

    Purpose: Although radiotherapy is highly effective in relieving bone pain due to cancer invasion, its mechanism remains unclear. The aim of this study was to explore this mechanism in an animal model system. Methods and Materials: A hind paw model of cancer pain was developed by transplanting a murine hepatocarcinoma, HCa-1, into the periosteal membrane of the foot dorsum of C3H/HeJ mice. Bone invasion from HCa-1 was histopathologically confirmed from sequential tumor sampling. For three experimental groups, a control (N), tumor without radiation (T), and tumor with radiation (TR), the development and level of pain were objectively examined in mice with a growing tumor by assessing pain-associated behavior. The differential expression of pain-related signals in the spinal cord was analyzed by proteomic analysis using high-resolution two-dimensional gel electrophoresis (2-DE) and mass spectrometry, and those of proteins by Western blotting. The pain-mediating neurotransmitters in the spinal cord were also examined by immunohistochemical staining for calcitonin gene-related peptide (CGRP) and substance P. Results: In the histopathologic examinations, bone invasion from HCa-1 was seen from Day 7 and was evident at Day 14 after transplantation, and measurable pain-associated behaviors were developed from Day 7. After 25 Gy of radiation to the tumors, the objective level of pain in the TR group decreased, with higher thresholds to mechanical and thermal stimulation than in the T group. From the 2-DE of spinal cord, 107 spots were identified; 12 proteins were changed more than fivefold because of tumor formation but then reversed after radiation in the tumor-bearing mice. The proteins involved included secretagogin, syntenin, P2X purinoreceptor 6 (P2X6), and Ca{sup 2+}/Calmodulin-dependent protein kinase 1 (CaM kinase 1), the functions of which have been known to be involved in the Ca{sup 2+}-signaling cascade, ATP-mediated fast synaptic transmission, or control of

  9. Modern Spirometry Supports Anesthetic Management in Small Animal Clinical Practice: A Case Series.

    Science.gov (United States)

    Calice, Ivana; Moens, Yves

    2016-01-01

    Modern spirometry, like no other monitoring technique, allows insight into breath-to-breath respiratory mechanics. Spirometers continuously measure volume, airway pressure, and flow while calculating and continuously displaying respiratory system compliance and resistance in the form of loops. The aim of this case series is to show how observation of spirometric loops, similar to electrocardiogram or CO2 curve monitoring, can improve safety of anesthetic management in small animals. Spirometric monitoring cases described in this case series are based on use of the anaesthesia monitor Capnomac Ultima with a side stream spirometry sensor. The cases illustrate how recognition and understanding of spirometric loops allows for easy diagnosis of iatrogenic pneumothorax, incorrect ventilator settings, leaks in the system, kinked or partially obstructed endotracheal tube, and spontaneous breathing interfering with intermittent positive-pressure ventilation. The case series demonstrates the potential of spirometry to improve the quality and safety of anesthetic management, and, hence, its use can be recommended during intermittent positive-pressure ventilation and procedures in which interference with ventilation can be expected.

  10. Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method

    International Nuclear Information System (INIS)

    ChavarrIas, C; Vaquero, J J; Sisniega, A; RodrIguez-Ruano, A; Soto-Montenegro, M L; GarcIa-Barreno, P; Desco, M

    2008-01-01

    We propose a retrospective respiratory gating algorithm to generate dynamic CT studies. To this end, we compared three different methods of extracting the respiratory signal from the projections of small-animal cone-beam computed tomography (CBCT) scanners. Given a set of frames acquired from a certain axial angle, subtraction of their average image from each individual frame produces a set of difference images. Pixels in these images have positive or negative values (according to the respiratory phase) in those areas where there is lung movement. The respiratory signals were extracted by analysing the shape of the histogram of these difference images: we calculated the first four central and non-central moments. However, only odd-order moments produced the desired breathing signal, as the even-order moments lacked information about the phase. Each of these curves was compared to a reference signal recorded by means of a pneumatic pillow. Given the similar correlation coefficients yielded by all of them, we selected the mean to implement our retrospective protocol. Respiratory phase bins were separated, reconstructed independently and included in a dynamic sequence, suitable for cine playback. We validated our method in five adult rat studies by comparing profiles drawn across the diaphragm dome, with and without retrospective respiratory gating. Results showed a sharper transition in the gated reconstruction, with an average slope improvement of 60.7%

  11. Performance of a DOI-encoding small animal PET system with monolithic scintillators

    International Nuclear Information System (INIS)

    Carles, M.; Lerche, Ch.W.; Sánchez, F.; Orero, A.; Moliner, L.; Soriano, A.; Benlloch, J.M.

    2012-01-01

    PET systems designed for specific applications require high resolution and sensitivity instrumentation. In dedicated system design smaller ring diameters and deeper crystals are widely used in order to increase the system sensitivity. However, this design increases the parallax error, which degrades the spatial image resolution gradually from the center to the edge of the field-of-view (FOV). Our group has designed a depth of interaction(DOI)-encoding small animal PET system based on monolithic crystals. In this work we investigate the restoration of radial resolution for transaxially off-center sources using the DOI information provided by our system. For this purpose we have designed a support for point like sources adapted to our system geometry that allows a spatial compression and resolution response study. For different point source radial positions along vertical and horizontal axes of a FOV transaxial plane we compare the results obtained by three methods: without DOI information, with the DOI provided by our system and with the assumption that all the γ-rays interact at half depth of the crystal thickness. Results show an improvement of the mean resolution of 10% with the half thickness assumption and a 16% achieved using the DOI provided by the system. Furthermore, a 10% restoration of the resolution uniformity is obtained using the half depth assumption and an 18% restoration using measured DOI.

  12. Digital signal processing applied to crystal identification in Positron Emission Tomography dedicated to small animals

    International Nuclear Information System (INIS)

    Fontaine, Rejean; Viscogliosi, Nicolas; Semmaoui, Hicham; Belanger, Francois; Lemieux, Francois; Tetrault, Marc-Andre; Michaud, Jean-Baptiste; Berard, Philippe; Cadorette, Jules; Pepin, Catherine M.; Lecomte, Roger

    2007-01-01

    The recent introduction of all-digital electronic architecture in Positron Emission Tomography (PET) scanners, enables new paradigms to be explored for extracting relevant information from the detector signals, such as energy, time and crystal identification. The LabPET TM small animal scanner, which implements free-running 45-MHz sampling directly at the output of the charge sensitive preamplifiers, provides an excellent platform to test such advanced digital algorithms. A real-time identification method, based on an Auto-Regressive Moving-Average (ARMA) scheme, was tested for discriminating between LYSO (t r ∼40 ns) and LGSO (t r ∼65 ns) scintillators in phoswich detectors, coupled to a single Avalanche Photodiode (APD). Even with a low energy threshold of 250 keV applied individually, error rates 10%, typically with conventional analog pulse shape discrimination techniques. Such digital crystal identification techniques can be readily implemented with phoswich detectors for improving spatial resolution in PET, either by increasing crystal pixellization or by mitigating parallax errors through depth-of-interaction determination. It also allows to reduce the event rate presented to the real-time coincidence engine by applying a low energy limit at the crystal granularity and rejecting more Compton photons

  13. Digital signal processing applied to crystal identification in Positron Emission Tomography dedicated to small animals

    Energy Technology Data Exchange (ETDEWEB)

    Fontaine, Rejean [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada)]. E-mail: Rejean.Fontaine@Usherbrooke.ca; Viscogliosi, Nicolas [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Semmaoui, Hicham [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Belanger, Francois [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Lemieux, Francois [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Tetrault, Marc-Andre [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Michaud, Jean-Baptiste [Department of Electrical and Computer Engineering, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Berard, Philippe [Department of Nuclear Medicine and Radiobiology, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Cadorette, Jules [Department of Nuclear Medicine and Radiobiology, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Pepin, Catherine M. [Department of Nuclear Medicine and Radiobiology, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada); Lecomte, Roger [Department of Nuclear Medicine and Radiobiology, Universite de Sherbrooke, 2500 Boul. Universite, Sherbrooke, Que., J1 K 2R1 (Canada)

    2007-02-01

    The recent introduction of all-digital electronic architecture in Positron Emission Tomography (PET) scanners, enables new paradigms to be explored for extracting relevant information from the detector signals, such as energy, time and crystal identification. The LabPET{sup TM} small animal scanner, which implements free-running 45-MHz sampling directly at the output of the charge sensitive preamplifiers, provides an excellent platform to test such advanced digital algorithms. A real-time identification method, based on an Auto-Regressive Moving-Average (ARMA) scheme, was tested for discriminating between LYSO (t{sub r}{approx}40 ns) and LGSO (t{sub r}{approx}65 ns) scintillators in phoswich detectors, coupled to a single Avalanche Photodiode (APD). Even with a low energy threshold of 250 keV applied individually, error rates<4% can be achieved, as compared to >10%, typically with conventional analog pulse shape discrimination techniques. Such digital crystal identification techniques can be readily implemented with phoswich detectors for improving spatial resolution in PET, either by increasing crystal pixellization or by mitigating parallax errors through depth-of-interaction determination. It also allows to reduce the event rate presented to the real-time coincidence engine by applying a low energy limit at the crystal granularity and rejecting more Compton photons.

  14. Climbing Mount Efficiency--small steps, not giant leaps towards higher cloning success in farm animals.

    Science.gov (United States)

    Oback, Björn

    2008-07-01

    Despite more than a decade of research efforts, farm animal cloning by somatic cell nuclear transfer (SCNT) is still frustratingly inefficient. Inefficiency manifests itself at different levels, which are currently not well integrated. At the molecular level, it leads to widespread genetic, epigenetic and transcriptional aberrations in cloned embryos. At the organismal level, these genome-wide abnormalities compromise development of cloned foetuses and offspring. Specific molecular defects need to be causally linked to specific cloned phenotypes, in order to design specific treatments to correct them. Cloning efficiency depends on the ability of the nuclear donor cell to be fully reprogrammed into an embryonic state and the ability of the enucleated recipient cell to carry out the reprogramming reactions. It has been postulated that reprogrammability of the somatic donor cell epigenome is influenced by its differentiation status. However, direct comparisons between cells of divergent differentiation status within several somatic lineages have found no conclusive evidence for this. Choosing somatic stem cells as donors has not improved cloning efficiency, indicating that donor cell type may be less critical for cloning success. Different recipient cells, on the other hand, vary in their reprogramming ability. In bovine, using zygotes instead of oocytes has increased cloning success. Other improvements in livestock cloning efficiency include better coordinating donor cell type with cell cycle stage and aggregating cloned embryos. In the future, it will be important to demonstrate if these small increases at every step are cumulative, adding up to an integrated cloning protocol with greatly improved efficiency.

  15. Evaluation of New Inorganic Scintillators for Application in a Prototype Small Animal PET Scanner

    CERN Document Server

    Kuntner, C

    2003-01-01

    In the study of new pharmaceuticals as well as brain and genetic research, Positron Emission Tomography (PET) is a useful method. It has also recently entered the clinical domain in cardiology and particularly in oncology. Small animals such as mice, are often used to validate sophisticated models of human disease. High spatial resolution PET instrumentation is therefore necessary due to the reduced dimensions of the organs. Inorganic scintillators are employed in most of the diagnostic imaging devices. The ultimate performance of the PET scanner is tightly bound to the scintillation properties of the crystals. In the last years there has been an effort to develop new scintillating materials characterized by high light output, high detection efficiency and fast decay time. The most studied systems are mainly Ce3+-doped crystals such as LSO:Ce, YAP:Ce, LuAP:Ce, and recently also mixed Lux(RE3+)1-xAlO3:Ce crystals. These crystals are very attractive for medical application because of their high density (with th...

  16. Visualization of transverse diffusion paths across fiber cells of the ocular lens by small animal MRI

    International Nuclear Information System (INIS)

    Vaghefi, Ehsan; Hunter, Peter J; Jacobs, Marc D; Pontre, Beau; Donaldson, Paul J

    2009-01-01

    The sense of vision requires that light penetrate through the ocular lens. Experiments, performed and published by many research groups, have suggested that the lens, which has no blood vessels, relies on internally directed ion and water fluxes for its circulation, survival and transparency. We investigated the internal diffusive pathways of the lens in order to better understand the constraints that may be operating on directional lens fluxes. Small animal magnetic resonance imaging, including T2-weighted and diffusion tensor imaging, was used to measure tissue properties and diffusivity throughout cultured bovine lenses. A range of concentric regions of signal intensity was distinguished inside the lens, by both T2-weighted signal and mean diffusivity. Diffusivity mapping of the lens revealed novel anisotropic polar and equatorial zones of pronounced diffusivity directed transverse to the fiber cells. In contrast, an inner zone including the lens nucleus showed isotropic and weak diffusivity. Our results lend support to models of internally directed lens micro-circulation, by placing non-structural diffusive constraints on global patterns of fluid circulation

  17. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    Energy Technology Data Exchange (ETDEWEB)

    Deng Hua [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Kennedy, Christopher W [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Armour, Elwood [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Tryggestad, Erik [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Ford, Eric [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); McNutt, Todd [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States); Jiang Licai [OSMIC Inc., 1900 Taylor Rd., Auburn Hills, MI (United States); Wong, John [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Baltimore, MD (United States)

    2007-05-21

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min{sup -1} at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of {+-}5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.

  18. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system.

    Science.gov (United States)

    Deng, Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang, Licai; Wong, John

    2007-05-21

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min(-1) at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of +/-5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD.

  19. Estimation of organ motion for gated PET imaging in small animal using artificial tumor

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang Keun; Yu, Jung Woo; Lee, Yong Jin [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-10-15

    The image quality is lowered by reducing of contrast and signal due to breathing and heart motion when acquire Positron Emission Tomography (PET) image of small animal tumor. Therefore motion correction is required for betterment of quantitative estimation of tumor. The gated PET using external monitoring device is commonly used for motion correction. But that method has limitation by reason of detection from the outside. Therefore, we had devised the in-vivo motion assessment. In-vivo motion has been demonstrated in lung, liver and abdomen region of rats by coated molecular sieve. In PET image analysis, count and SNR were drawn in the target region. The motion compensation PET image for optimal gate number was confirmed by FWHM. Artificial motion evaluation of tumor using molecular sieve suggests possibility of motion correction modeling without external monitoring devices because it estimates real internal motion of lung, liver, and abdomen. The purpose of this study was to assess the optimal gates number for each region and to improve quantitative estimation of tumor

  20. Using ground penetrating radar in levee assessment to detect small scale animal burrows

    Science.gov (United States)

    Chlaib, Hussein K.; Mahdi, Hanan; Al-Shukri, Haydar; Su, Mehmet M.; Catakli, Aycan; Abd, Najah

    2014-04-01

    Levees are civil engineering structures built to protect human lives, property, and agricultural lands during flood events. To keep these important structures in a safe condition, continuous monitoring must be performed regularly and thoroughly. Small rodent burrows are one of the major defects within levees; however, their early detection and repair helps in protecting levees during flooding events. A set of laboratory experiments was conducted to analyze the polarity change in GPR signals in the presence of subsurface voids and water-filled cavities. Ground Penetrating Radar (GPR) surveys using multi frequency antennas (400 MHz and 900 MHz) were conducted along an 875 meter section of the Lollie Levee near Conway, Arkansas, USA, to assess the levee's structural integrity. Many subsurface animal burrows, water-filled cavities, clay clasts, and metallic objects were investigated and identified. These anomalies were located at different depths and have different sizes. To ground truth the observations, hand dug trenches were excavated to confirm several anomalies. Results show an excellent match between GPR interpreted anomalies and the observed features. In-situ dielectric constant measurements were used to calculate the feature depths. The results of this research show that the 900 MHz antenna has more advantages over the 400 MHz antenna.

  1. Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method

    Energy Technology Data Exchange (ETDEWEB)

    ChavarrIas, C; Vaquero, J J; Sisniega, A; RodrIguez-Ruano, A; Soto-Montenegro, M L; GarcIa-Barreno, P; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Anexo PsiquiatrIa, 1 Planta. C/Ibiza, 43. Madrid 28007 (Spain)

    2008-09-07

    We propose a retrospective respiratory gating algorithm to generate dynamic CT studies. To this end, we compared three different methods of extracting the respiratory signal from the projections of small-animal cone-beam computed tomography (CBCT) scanners. Given a set of frames acquired from a certain axial angle, subtraction of their average image from each individual frame produces a set of difference images. Pixels in these images have positive or negative values (according to the respiratory phase) in those areas where there is lung movement. The respiratory signals were extracted by analysing the shape of the histogram of these difference images: we calculated the first four central and non-central moments. However, only odd-order moments produced the desired breathing signal, as the even-order moments lacked information about the phase. Each of these curves was compared to a reference signal recorded by means of a pneumatic pillow. Given the similar correlation coefficients yielded by all of them, we selected the mean to implement our retrospective protocol. Respiratory phase bins were separated, reconstructed independently and included in a dynamic sequence, suitable for cine playback. We validated our method in five adult rat studies by comparing profiles drawn across the diaphragm dome, with and without retrospective respiratory gating. Results showed a sharper transition in the gated reconstruction, with an average slope improvement of 60.7%.

  2. SmartPET: Applying HPGe and pulse shape analysis to small-animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool (United Kingdom)], E-mail: rjc@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Mather, A.R.; Nolan, P.J.; Scraggs, D.P.; Turk, G. [Department of Physics, University of Liverpool (United Kingdom); Hall, C.J.; Lazarus, I. [CCLRC Daresbury Laboratory, Warrington, Cheshire (United Kingdom); Berry, A.; Beveridge, T.; Gillam, J.; Lewis, R.A. [School of Physics and Materials Engineering, Monash University, Melbourne (Australia)

    2007-08-21

    The SmartPET project is the development of a prototype small-animal imaging system based on the use of Hyperpure Germanium (HPGe) detectors. The use of digital electronics and application of Pulse Shape Analysis (PSA) techniques provide fine spatial resolution, while the excellent intrinsic energy resolution of HPGe detectors makes the system ideal for multi-nuclide imaging. As a result, the SmartPET system has the potential to function as a dual modality imager, operating as a dual-head Positron Emission Tomography (PET) camera or in a Compton Camera configuration for Single Photon Emission Computed Tomography (SPECT) imaging. In this paper, we discuss how the use of simple PSA techniques greatly improves the position sensitivity of the detector yielding improved spatial resolution in reconstructed images. The PSA methods presented have been validated by comparison to data from high-precision scanning of the detectors. Results from this analysis are presented along with initial images from the SmartPET system, which demonstrates the impact of these techniques on PET images.

  3. A small animal image guided irradiation system study using 3D dosimeters

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Admovics, John

    2015-01-01

    In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies

  4. A portable telemetry system for brain stimulation and neuronal activity recording in freely behaving small animals.

    Science.gov (United States)

    Ye, Xuesong; Wang, Peng; Liu, Jun; Zhang, Shaomin; Jiang, Jun; Wang, Qingbo; Chen, Weidong; Zheng, Xiaoxiang

    2008-09-30

    A portable multi-channel telemetry system which can be used for brain stimulation and neuronal activity recording in freely behaving small animals is described here. This system consists of three major components of headstage, backpack and portable Personal Digital Assistant (PDA). The headstage contains high precision instrument amplifiers with high input impedance. The backpack is comprised of two parts: (1) a main board (size: 36 mm x 22 mm x 3.5 mm and weight: 40 g with batteries, 20 g without), with current/voltage stimulator and special circuit suitable for neuronal activity recording and (2) and a bluetooth transceiver, with a high data transmission rate up to 70 kb/s, suitable for downloading stimulation commands and uploading acquired data. We recorded neuronal activities of the primary motor area of a freely behaving rat with 12-bit resolution at 12 k samples/s. The recorded data and analysis results showed that the system was successful by comparing with the commercial equipment Cerebus 128-Channel Data Acquisition System (Cyberkinetics Inc.). Using the PDA, we can control stimulation and recording. It provides a flexible method to do some research work in the circumstances where other approaches would be difficult or impossible.

  5. Development of a Si-PM-based high-resolution PET system for small animals

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Imaizumi, Masao; Watabe, Tadashi; Shimosegawa, Eku; Hatazawa, Jun; Watabe, Hiroshi; Kanai, Yasukazu

    2010-01-01

    A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 x 4 Si-PM arrays (S11065-025P) were used for its detector blocks. Two types of LGSO scintillator of 0.75 mol% Ce (decay time: ∼45 ns; 1.1 mm x 1.2 mm x 5 mm) and 0.025 mol% Ce (decay time: ∼31 ns; 1.1 mm x 1.2 mm x 6 mm) were optically coupled in the DOI direction to form a DOI detector, arranged in a 11 x 9 matrix, and optically coupled to the Si-PM array. Pulse shape analysis was used for the DOI detection of these two types of LGSOs. Sixteen detector blocks were arranged in a 68 mm diameter ring to form the PET system. Spatial resolution was 1.6 mm FWHM and sensitivity was 0.6% at the center of the field of view. High-resolution mouse and rat images were successfully obtained using the PET system. We confirmed that the developed Si-PM-based PET system is promising for molecular imaging research.

  6. Modeling and characterization of a SPECT system with pinhole collimation for the imaging of small animals

    International Nuclear Information System (INIS)

    Auer, Benjamin

    2017-01-01

    My thesis work focuses on the development of several quantitative reconstruction methods dedicated to small animal Single Photon Emission Computed Tomography (SPECT). The latter is based on modeling the acquisition process of the 4-heads pinhole SPECT system available at Institut Pluridisciplinaire Hubert Curien (IPHC) and fully integrated to the AMISSA platform using Monte Carlo simulations. The system matrix approach, combined with the OS-EM iterative reconstruction algorithm, enabled to characterize the system performances and to compare it to the state of the art. Sensitivity of about 0,027% in the center of the field of view associated to a tomographic spatial resolution of 0, 875 ± 0, 025 mm were obtained. The major drawbacks of Monte Carlo methods led us to develop an efficient and simplified modeling of the physical effects occurring in the subject. My approach based on a system matrix decomposition, associated to a scatter pre-calculated database method, demonstrated an acceptable time for a daily imaging subject follow-up (∼ 1 h), leading to a personalized imaging reconstruction (article accepted). The inherent approximations of the scatter pre-calculated approach (first order scattering modeling and segmented emission) have a moderate impact on the recovery coefficients results, nevertheless a correction of about 10% was achieved. (author) [fr

  7. Model-Based Normalization of a Fractional-Crystal Collimator for Small-Animal PET Imaging.

    Science.gov (United States)

    Li, Yusheng; Matej, Samuel; Karp, Joel S; Metzler, Scott D

    2017-05-01

    Previously, we proposed to use a coincidence collimator to achieve fractional-crystal resolution in PET imaging. We have designed and fabricated a collimator prototype for a small-animal PET scanner, A-PET. To compensate for imperfections in the fabricated collimator prototype, collimator normalization, as well as scanner normalization, is required to reconstruct quantitative and artifact-free images. In this study, we develop a normalization method for the collimator prototype based on the A-PET normalization using a uniform cylinder phantom. We performed data acquisition without the collimator for scanner normalization first, and then with the collimator from eight different rotation views for collimator normalization. After a reconstruction without correction, we extracted the cylinder parameters from which we generated expected emission sinograms. Single scatter simulation was used to generate the scattered sinograms. We used the least-squares method to generate the normalization coefficient for each LOR based on measured, expected and scattered sinograms. The scanner and collimator normalization coefficients were factorized by performing two normalizations separately. The normalization methods were also verified using experimental data acquired from A-PET with and without the collimator. In summary, we developed a model-base collimator normalization that can significantly reduce variance and produce collimator normalization with adequate statistical quality within feasible scan time.

  8. FIMTrack: An open source tracking and locomotion analysis software for small animals.

    Directory of Open Access Journals (Sweden)

    Benjamin Risse

    2017-05-01

    Full Text Available Imaging and analyzing the locomotion behavior of small animals such as Drosophila larvae or C. elegans worms has become an integral subject of biological research. In the past we have introduced FIM, a novel imaging system feasible to extract high contrast images. This system in combination with the associated tracking software FIMTrack is already used by many groups all over the world. However, so far there has not been an in-depth discussion of the technical aspects. Here we elaborate on the implementation details of FIMTrack and give an in-depth explanation of the used algorithms. Among others, the software offers several tracking strategies to cover a wide range of different model organisms, locomotion types, and camera properties. Furthermore, the software facilitates stimuli-based analysis in combination with built-in manual tracking and correction functionalities. All features are integrated in an easy-to-use graphical user interface. To demonstrate the potential of FIMTrack we provide an evaluation of its accuracy using manually labeled data. The source code is available under the GNU GPLv3 at https://github.com/i-git/FIMTrack and pre-compiled binaries for Windows and Mac are available at http://fim.uni-muenster.de.

  9. Pinhole SPECT: high resolution imaging of brain tumours in small laboratory animals

    International Nuclear Information System (INIS)

    Franceschim, M.; Bokulic, T.; Kusic, Z.; Strand, S.E.; Erlandsson, K.

    1994-01-01

    The performance properties of pinhole SPECT and the application of this technology to evaluate radionuclide uptake in brain in small laboratory animals were investigated. System sensitivity and spatial resolution measurements of a rotating scintillation camera system were made for a low energy pinhole collimator equipped with 2.0 mm aperture pinhole insert. Projection data were acquired at 4 degree increments over 360 degrees in the step and shoot mode using a 4.5 cm radius of rotation. Pinhole planar and SPECT imaging were obtained to evaluate regional uptake of Tl-201, Tc-99m-MIBI, Tc-99m-HMPAO and Tc-99m-DTPA in tumor and control regions of the brain in a primary brain tumor model in Fisher 344 rats. Pinhole SPECT images were reconstructed using a modified cone- beam algorithm developed from a two dimensional fan-beam filtered backprojection algorithm. The reconstructed transaxial resolution of 2.8 FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0 mm pinhole collimator aperture were measured. Tumor to non-tumor uptake ratios at 19-28 days post tumor cell inoculation varied by a factor > 20:1 on SPECT images. Pinhole SPECT provides an important new approach for performing high resolution imaging: the resolution properties of pinhole SPECT are superior to those which have been achieved with conventional SPECT or PET imaging technologies. (author)

  10. The small-animal radiation research platform (SARRP): dosimetry of a focused lens system

    International Nuclear Information System (INIS)

    Deng Hua; Kennedy, Christopher W; Armour, Elwood; Tryggestad, Erik; Ford, Eric; McNutt, Todd; Jiang Licai; Wong, John

    2007-01-01

    A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV. Here, we report on the dosimetric characteristics of the focused beam from the x-ray lens subsystem for high-resolution dose delivery. Using the metric of the average dose within a 1.5 mm diameter area, the dose rates at a source-to-surface distance (SSD) of 34 cm are 259 and 172 cGy min -1 at 6 mm and 2 cm depths, respectively, with an estimated uncertainty of ±5%. The per cent depth dose is approximately 56% at 2 cm depth for a beam at 34 cm SSD

  11. Angiogenic dysfunction in bone marrow-derived early outgrowth cells from diabetic animals is attenuated by SIRT1 activation.

    Science.gov (United States)

    Yuen, Darren A; Zhang, Yanling; Thai, Kerri; Spring, Christopher; Chan, Lauren; Guo, Xiaoxin; Advani, Andrew; Sivak, Jeremy M; Gilbert, Richard E

    2012-12-01

    Impaired endothelial repair is a key contributor to microvascular rarefaction and consequent end-organ dysfunction in diabetes. Recent studies suggest an important role for bone marrow-derived early outgrowth cells (EOCs) in mediating endothelial repair, but the function of these cells is impaired in diabetes, as in advanced age. We sought to determine whether diabetes-associated EOC dysfunction might be attenuated by pharmacological activation of silent information regulator protein 1 (SIRT1), a lysine deacetylase implicated in nutrient-dependent life span extension in mammals. Despite being cultured in normal (5.5 mM) glucose for 7 days, EOCs from diabetic rats expressed less SIRT1 mRNA, induced less endothelial tube formation in vitro and neovascularization in vivo, and secreted less of the proangiogenic ELR(+) CXC chemokines CXCL1, CXCL3, and CXCL5. Ex vivo SIRT1 activation restored EOC chemokine secretion and increased the in vitro and in vivo angiogenic activity of EOC conditioned medium derived from diabetic animals to levels similar to that derived from control animals. These findings suggest a pivotal role for SIRT1 in diabetes-induced EOC dysfunction and that its pharmacologic activation may provide a new strategy for the restoration of EOC-mediated repair mechanisms.

  12. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    International Nuclear Information System (INIS)

    Ochoa Domínguez, Humberto de Jesús; Máynez, Leticia O.; Vergara Villegas, Osslan O.; Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G.

    2015-01-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image

  13. Denoising of high resolution small animal 3D PET data using the non-subsampled Haar wavelet transform

    Energy Technology Data Exchange (ETDEWEB)

    Ochoa Domínguez, Humberto de Jesús, E-mail: hochoa@uacj.mx [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Máynez, Leticia O. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Vergara Villegas, Osslan O. [Departamento de Ingeniería Industrial, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico); Mederos, Boris; Mejía, José M.; Cruz Sánchez, Vianey G. [Departamento de Ingeniería Eléctrica y computación, Universidad Autónoma de Ciudad Juárez, Ciudad Juárez, Chih. (Mexico)

    2015-06-01

    PET allows functional imaging of the living tissue. However, one of the most serious technical problems affecting the reconstructed data is the noise, particularly in images of small animals. In this paper, a method for high-resolution small animal 3D PET data is proposed with the aim to reduce the noise and preserve details. The method is based on the estimation of the non-subsampled Haar wavelet coefficients by using a linear estimator. The procedure is applied to the volumetric images, reconstructed without correction factors (plane reconstruction). Results show that the method preserves the structures and drastically reduces the noise that contaminates the image.

  14. Fabrication of a small animal restraint for synchrotron biomedical imaging using a rapid prototyper

    International Nuclear Information System (INIS)

    Zhu Ying; Zhang Honglin; McCrea, Richard; Bewer, Brian; Wiebe, Sheldon; Nichol, Helen; Ryan, Christopher; Wysokinski, Tomasz; Chapman, Dean

    2007-01-01

    Biomedical research at synchrotron facilities may involve imaging live animals that must remain motionless for extended periods of time to obtain quality images. Even breathing movements reduce image quality but on the other hand excessive restraint of animals increases morbidity and mortality. We describe a humane animal restraint designed to eliminate head movements while promoting animal survival. This paper describes how an animal restraint that conforms to the shape of an animal's head was fabricated by a 3D prototyper. The method used to translate medical computed tomography (CT) data to a 3D stereolithography format is described and images of its use at the Canadian Light Source (CLS) are shown. This type of restraint holds great promise in improving image quality and repeatability while reducing stress on experimental animals

  15. Osteoporosis in water buffalo, in relation to age, clinical condition of the animal and physical-chemical bone and hepatic copper status

    Directory of Open Access Journals (Sweden)

    Washington Luiz Assunção Pereira

    2010-04-01

    Full Text Available This paper is part of a research program of metabolic nutritional diseases in water buffalo in the Humid Tropical Amazon. In that context, the objective was to study osteoporotic processes in buffalo raised in a grazing system on Marajó Island and the relation of the disease with the age as well as physical-chemical bone and hepatic copper status. One hundred and ten animals were evaluated: 39 young or juvenile and 71 adults that presented Body Condition Index from 1 to 2. One group was composed by young buffalo and another by adult animals. Based on anatomical-clinical and bone quality analyses, the animals were subdivided in two sub-groups, according to presence or absence of clinical signs of apparent osteopathic. Analysis of calcium, phosphorus, ash and bone density was performed on the middle third of the 11th right rib, and the copper concentration was determined from liver tissue. Pathological anatomical findings showed that 98.44% of juvenile animals and 96.16% of adult animals, respectively, presented some degree of osteoporosis (+, ++, +++. Low average percentages were demonstrated for phosphorus (10.69%, in ashes (60.24% and in density (1.46 g/ml. Hepatic copper presented similar low values (19.51 mg/kg. The results showed that juvenile animals presented more severe clinical sign of osteoporosis, and the pathogenesis may be related to low reserves of phosphorus in bony tissue and copper in liver tissue.

  16. Malignant lymphoma incidentally diagnosed due to the perforation of the small intestine caused by a fish bone: A case report

    Directory of Open Access Journals (Sweden)

    Masatsugu Hiraki

    Full Text Available Introduction: The ingestion of a foreign body is relatively common. However, it rarely results in the perforation of gastrointestinal tract. We herein report an unusual case of malignant lymphoma in