WorldWideScience

Sample records for skinfold thickness

  1. Body fat assessed from body density and estimated from skinfold thickness in normal children and children with cystic fibrosis.

    Science.gov (United States)

    Johnston, J L; Leong, M S; Checkland, E G; Zuberbuhler, P C; Conger, P R; Quinney, H A

    1988-12-01

    Body density and skinfold thickness at four sites were measured in 140 normal boys, 168 normal girls, and 6 boys and 7 girls with cystic fibrosis, all aged 8-14 y. Prediction equations for the normal boys and girls for the estimation of body-fat content from skinfold measurements were derived from linear regression of body density vs the log of the sum of the skinfold thickness. The relationship between body density and the log of the sum of the skinfold measurements differed from normal for the boys and girls with cystic fibrosis because of their high body density even though their large residual volume was corrected for. However the sum of skinfold measurements in the children with cystic fibrosis did not differ from normal. Thus body fat percent of these children with cystic fibrosis was underestimated when calculated from body density and invalid when calculated from skinfold thickness.

  2. High-Impact Aerobic and Zumba Fitness on Increasing VO2MAX, Heart Rate Recovery and Skinfold Thickness

    Science.gov (United States)

    Suminar, T. J.; Kusnanik, N. W.; Wiriawan, O.

    2018-01-01

    Purpose of this study is to determine the significant effect of high-impact aerobics exercise, and Zumba fitness on increasing VO2Max, decreasing of heart rate recovery, and decreasing of skinfold thickness. A sample of this study is 30 members aerobics of student activity unit. Type of this study was quantitative by using a quasi-experimental design method. The design of this study used Matching-Only Design. Data were Analyzed by using the t test (paired t-test). The samples divided into three groups consisted of experimental group I, experimental group II, and control group. They were given a treatment for 8 weeks or 24 meeting. For the data, retrieval is done by MFT test, heart rate recovery test, and skinfold thickness test. Furthermore, the result was analyzed by using SPSS 21 series. In conclusion, significant effect of high-impact aerobics and Zumba fitness on increasing VO2Max, heart rate recovery, skinfold thickness.

  3. Sex differences in association of race performance, skin-fold thicknesses, and training variables for recreational half-marathon runners.

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Senn, Oliver

    2010-12-01

    The purpose of this study was to investigate the association between selected skin-fold thicknesses and training variables with a half-marathon race time, for both male and female recreational runners, using bi- and multivariate analysis. In 52 men, two skin-fold thicknesses (abdominal and calf) were significantly and positively correlated with race time; whereas in 15 women, five (pectoral, mid-axilla, subscapular, abdominal, and suprailiac) showed positive and significant relations with total race time. In men, the mean weekly running distance, minimum distance run per week, maximum distance run per week, mean weekly hours of running, number of running training sessions per week, and mean speed of the training sessions were significantly and negatively related to total race time, but not in women. Interaction analyses suggested that race time was more strongly associated with anthropometry in women than men. Race time for the women was independently associated with the sum of eight skin-folds; but for the men, only the mean speed during training sessions was independently associated. Skin-fold thicknesses and training variables in these groups were differently related to race time according to their sex.

  4. Triceps and Subscapular Skinfold Thickness Percentiles and Cut-Offs for Overweight and Obesity in a Population-Based Sample of Schoolchildren and Adolescents in Bogota, Colombia

    Science.gov (United States)

    Ramírez-Vélez, Robinson; López-Cifuentes, Mario Ferney; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Córdoba-Rodríguez, Diana Paola; Vivas, Andrés; Triana-Reina, Hector Reynaldo; Schmidt-RioValle, Jacqueline

    2016-01-01

    The assessment of skinfold thickness is an objective measure of adiposity. The aims of this study were to establish Colombian smoothed centile charts and LMS L (Box–Cox transformation), M (median), and S (coefficient of variation) tables for triceps, subscapular, and triceps + subscapular skinfolds; appropriate cut-offs were selected using receiver operating characteristic (ROC) analysis based on a population-based sample of children and adolescents in Bogotá, Colombia. A cross-sectional study was conducted in 9618 children and adolescents (55.7% girls; age range of 9–17.9 years). Triceps and subscapular skinfold measurements were obtained using standardized methods. We calculated the triceps + subscapular skinfold (T + SS) sum. Smoothed percentile curves for triceps and subscapular skinfold thickness were derived using the LMS method. ROC curve analyses were used to evaluate the optimal cut-off point of skinfold thickness for overweight and obesity, based on the International Obesity Task Force definitions. Subscapular and triceps skinfolds and T + SS were significantly higher in girls than in boys (p < 0.001). The ROC analysis showed that subscapular and triceps skinfolds and T + SS have a high discriminatory power in the identification of overweight and obesity in the sample population in this study. Our results provide sex- and age-specific normative reference standards for skinfold thickness values from a population from Bogotá, Colombia. PMID:27669294

  5. Triceps and Subscapular Skinfold Thickness Percentiles and Cut-Offs for Overweight and Obesity in a Population-Based Sample of Schoolchildren and Adolescents in Bogota, Colombia

    Directory of Open Access Journals (Sweden)

    Robinson Ramírez-Vélez

    2016-09-01

    Full Text Available The assessment of skinfold thickness is an objective measure of adiposity. The aims of this study were to establish Colombian smoothed centile charts and LMS L (Box–Cox transformation, M (median, and S (coefficient of variation tables for triceps, subscapular, and triceps + subscapular skinfolds; appropriate cut-offs were selected using receiver operating characteristic (ROC analysis based on a population-based sample of children and adolescents in Bogotá, Colombia. A cross-sectional study was conducted in 9618 children and adolescents (55.7% girls; age range of 9–17.9 years. Triceps and subscapular skinfold measurements were obtained using standardized methods. We calculated the triceps + subscapular skinfold (T + SS sum. Smoothed percentile curves for triceps and subscapular skinfold thickness were derived using the LMS method. ROC curve analyses were used to evaluate the optimal cut-off point of skinfold thickness for overweight and obesity, based on the International Obesity Task Force definitions. Subscapular and triceps skinfolds and T + SS were significantly higher in girls than in boys (p < 0.001. The ROC analysis showed that subscapular and triceps skinfolds and T + SS have a high discriminatory power in the identification of overweight and obesity in the sample population in this study. Our results provide sex- and age-specific normative reference standards for skinfold thickness values from a population from Bogotá, Colombia.

  6. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study

    Science.gov (United States)

    West, Jane; Manchester, Ben; Wright, John; Lawlor, Debbie A; Waiblinger, Dagmar

    2011-01-01

    Summary West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. PMID:21281329

  7. The relationship between skinfold thickness and body mass index in North European Caucasian and East Asian women with anorexia nervosa: implications for diagnosis and management.

    Science.gov (United States)

    Soh, Nerissa L; Touyz, Stephen; Dobbins, Timothy A; Clarke, Simon; Kohn, Michael R; Lee, Ee Lian; Leow, Vincent; Ung, Ken E K; Walter, Garry

    2009-01-01

    To investigate the relationship between skinfold thickness and body mass index (BMI) in North European Caucasian and East Asian young women with and without anorexia nervosa (AN) in two countries. Height, weight and skinfold thicknesses were assessed in 137 young women with and without AN, in Australia and Singapore. The relationship between BMI and the sum of triceps, biceps, subscapular and iliac crest skinfolds was analysed with clinical status, ethnicity, age and country of residence as covariates. For the same BMI, women with AN had significantly smaller sums of skinfolds than women without AN. East Asian women both with and without AN had significantly greater skinfold sums than their North European Caucasian counterparts after adjusting for BMI. Lower BMI goals may be appropriate when managing AN patients of East Asian ancestry and the weight for height diagnostic criterion should be reconsidered for this group.

  8. Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation.

    Science.gov (United States)

    Medeiros, Flávia V A; Vieira, Amilton; Carregaro, Rodrigo L; Bottaro, Martim; Maffiuletti, Nicola A; Durigan, João L Q

    2015-01-01

    Subcutaneous adipose tissue may influence the transmission of electrical stimuli through to the skin, thus affecting both evoked torque and comfort perception associated with neuromuscular electrical stimulation (NMES). This could seriously affect the effectiveness of NMES for either rehabilitation or sports purposes. To investigate the effects of skinfold thickness (SFT) on maximal NMES current intensity, NMES-evoked torque, and NMES-induced discomfort. First, we compared NMES current intensity, NMES-induced discomfort, and NMES-evoked torque between two subgroups of subjects with thicker (n=10; 20.7 mm) vs. thinner (n=10; 29.4 mm) SFT. Second, we correlated SFT to NMES current intensity, NMES-induced discomfort, and NMES-evoked knee extension torque in 20 healthy women. The NMES-evoked torque was normalized to the maximal voluntary contraction (MVC) torque. The discomfort induced by NMES was assessed with a visual analog scale (VAS). NMES-evoked torque was 27.5% lower in subjects with thicker SFT (p=0.01) while maximal current intensity was 24.2% lower in subjects with thinner SFT (p=0.01). A positive correlation was found between current intensity and SFT (r=0.540, p=0.017). A negative correlation was found between NMES-evoked torque and SFT (r=-0.563, p=0.012). No significant correlation was observed between discomfort scores and SFT (rs=0.15, p=0.53). These results suggest that the amount of subcutaneous adipose tissue (as reflected by skinfold thickness) affected NMES current intensity and NMES-evoked torque, but had no effect on discomfort perception. Our findings may help physical therapists to better understand the impact of SFT on NMES and to design more rational stimulation strategies.

  9. Relationships between neonatal weight, limb lengths, skinfold thicknesses, body breadths and circumferences in an Australian cohort.

    Directory of Open Access Journals (Sweden)

    Emma Pomeroy

    Full Text Available Low birth weight has been consistently associated with adult chronic disease risk. The thrifty phenotype hypothesis assumes that reduced fetal growth impacts some organs more than others. However, it remains unclear how birth weight relates to different body components, such as circumferences, adiposity, body segment lengths and limb proportions. We hypothesized that these components vary in their relationship to birth weight.We analysed the relationship between birth weight and detailed anthropometry in 1270 singleton live-born neonates (668 male from the Mater-University of Queensland Study of Pregnancy (Brisbane, Australia. We tested adjusted anthropometry for correlations with birth weight. We then performed stepwise multiple regression on birth weight of: body lengths, breadths and circumferences; relative limb to neck-rump proportions; or skinfold thicknesses. All analyses were adjusted for sex and gestational age, and used logged data.Circumferences, especially chest, were most strongly related to birth weight, while segment lengths (neck-rump, thigh, upper arm, and especially lower arm and lower leg were relatively weakly related to birth weight, and limb lengths relative to neck-rump length showed no relationship. Skinfolds accounted for 36% of birth weight variance, but adjusting for size (neck-rump, thigh and upper arm lengths, and head circumference, this decreased to 10%. There was no evidence that heavier babies had proportionally thicker skinfolds.Neonatal body measurements vary in their association with birth weight: head and chest circumferences showed the strongest associations while limb segment lengths did not relate strongly to birth weight. After adjusting for body size, subcutaneous fatness accounted for a smaller proportion of birth weight variance than previously reported. While heavier babies had absolutely thicker skinfolds, this was proportional to their size. Relative limb to trunk length was unrelated to birth

  10. Percentile curves for skinfold thickness for Canadian children and youth.

    Science.gov (United States)

    Kuhle, Stefan; Ashley-Martin, Jillian; Maguire, Bryan; Hamilton, David C

    2016-01-01

    Background. Skinfold thickness (SFT) measurements are a reliable and feasible method for assessing body fat in children but their use and interpretation is hindered by the scarcity of reference values in representative populations of children. The objective of the present study was to develop age- and sex-specific percentile curves for five SFT measures (biceps, triceps, subscapular, suprailiac, medial calf) in a representative population of Canadian children and youth. Methods. We analyzed data from 3,938 children and adolescents between 6 and 19 years of age who participated in the Canadian Health Measures Survey cycles 1 (2007/2009) and 2 (2009/2011). Standardized procedures were used to measure SFT. Age- and sex-specific centiles for SFT were calculated using the GAMLSS method. Results. Percentile curves were materially different in absolute value and shape for boys and girls. Percentile girls in girls steadily increased with age whereas percentile curves in boys were characterized by a pubertal centered peak. Conclusions. The current study has presented for the first time percentile curves for five SFT measures in a representative sample of Canadian children and youth.

  11. Impact of the use of different skinfold calipers for the analysis of the body composition

    Directory of Open Access Journals (Sweden)

    Cyrino Edilson Serpeloni

    2003-01-01

    Full Text Available With the advances in the studies of body composition, it has been observed that several factors can interfere with the estimates of relative body fat using the skinfold thicknesses method. Therefore, the purpose of this study was to investigate the impact of the use of different skinfold calipers for the analysis of body composition by skinfold thicknesses measurements. Two hundred and fifty nine male subjects (23.3 ± 2.9 years took part of the study. Nine skinfold thicknesses were measured (abdominal, subscapular, suprailiac, triceps, biceps, midaxillary, chest, medial calf, and thigh using the Lange (USA and the Cescorf (Brazil calipers with accuracy of 1.0 and 0.1 mm, respectively. Significant differences were found in the comparison between the two calipers on all the investigated skinfold thicknesses (1.8 to 31.0% with highest values obtained by the Lange caliper (p < 0.01. When these values were applied to four different predictive equations, developed by different researchers, the body fat estimate was significantly modified (p < 0.01, resulting in differences of 5.2 to 6.9%. Results indicate that the use of different skinfold calipers may maximize the errors of estimation produced by different predictive equations used for the analysis of body composition.

  12. Trends in the prevalence of elevated skinfold thickness among children and adolescents in Shandong Province, China, 1995-2014.

    Science.gov (United States)

    Wang, Shu-Rong; Cheng, Yan; Chen, Min; Zhang, Ying-Xiu

    2018-04-04

    There are abundant data on secular trends in BMI; however, information on the change in subcutaneous fat is limited. The present study examined the trends in the prevalence of elevated skinfold thickness among children and adolescents over the past 19 years (1995-2014) in Shandong Province, China. Data for the study were obtained from two cross-sectional surveys of schoolchildren carried out in 1995 and 2014. Triceps and subscapular skinfold thicknesses (SFT) of all participants were measured. The sum of triceps and subscapular SFT (SSFT) was applied. Children and adolescents with SSFT above or equal to the national age- and sex-specific 85th percentile were defined as 'high SFT'. Shandong Province, China. A total of 16 917 students aged 7-18 years were included. For both boys and girls, an increasing trend in 'high SFT' was observed between 1995 and 2014. The overall prevalence of 'high SFT' increased from 10·31 % for boys and 13·40 % for girls in 1995 to 33·94 % for boys and 29·30 % for girls in 2014 (P<0·01). There are more children and adolescents with very high levels of SFT. These trends describe very unfavourable changes in the body composition and should give cause for concern.

  13. Percentile curves for skinfold thickness for Canadian children and youth

    Directory of Open Access Journals (Sweden)

    Stefan Kuhle

    2016-07-01

    Full Text Available Background. Skinfold thickness (SFT measurements are a reliable and feasible method for assessing body fat in children but their use and interpretation is hindered by the scarcity of reference values in representative populations of children. The objective of the present study was to develop age- and sex-specific percentile curves for five SFT measures (biceps, triceps, subscapular, suprailiac, medial calf in a representative population of Canadian children and youth. Methods. We analyzed data from 3,938 children and adolescents between 6 and 19 years of age who participated in the Canadian Health Measures Survey cycles 1 (2007/2009 and 2 (2009/2011. Standardized procedures were used to measure SFT. Age- and sex-specific centiles for SFT were calculated using the GAMLSS method. Results. Percentile curves were materially different in absolute value and shape for boys and girls. Percentile girls in girls steadily increased with age whereas percentile curves in boys were characterized by a pubertal centered peak. Conclusions. The current study has presented for the first time percentile curves for five SFT measures in a representative sample of Canadian children and youth.

  14. Dual-energy X-ray absorptiometry, skinfold thickness and waist circumference for assessing body composition in ambulant and non-ambulant wheelchair games players

    Directory of Open Access Journals (Sweden)

    Annika eWillems

    2015-11-01

    Full Text Available Field-based assessments provide a cost–effective and accessible alternative to dual-energy X-ray absorptiometry (DXA for practitioners determining body composition in athletic populations. It remains unclear how the range of physical impairments classifiable in wheelchair sports may affect the utility of field-based body composition techniques. The present study assessed body composition using DXA in 14 wheelchair games players who were either wheelchair dependent (non-walkers; n =7 or relied on a wheelchair for sports participation only (walkers; n =7. Anthropometric measurements were used to predict body fat percentage with existing regression equations established for able-bodied persons by Sloan & Weir, Durnin & Womersley, Lean et al, Gallagher et al and Pongchaiyakul et al. In addition, linear regression analysis was performed to calculate the association between body fat percentage and BMI, waist circumference, sum of 6 skinfold thicknesses and sum of 8 skinfold thicknesses. Results showed that non-walkers had significantly lower total lean tissue mass (46.2±=6.6 kg vs. 59.4±8.2 kg, P =.006 and total body mass (65.8 ±4.2 kg vs. 79.4 ±14.9 kg; P =0.05 than walkers. Body fat percentage calculated from most existing regression equations was significantly lower than that from DXA, by 2 to 9% in walkers and 8 to14% in non-walkers. Of the anthropometric measurements, the sum of 8 skinfold thicknesses had the lowest standard error of estimation in predicting body fat content. In conclusion, existing anthropometric equations developed in able-bodied populations substantially underestimated body fat content in wheelchair athletes, particularly non-walkers. Impairment specific equations may be needed in wheelchair athletes.

  15. Skinfold thickness, body fat percentage and body mass index in obese and non-obese Indian boys.

    Science.gov (United States)

    Chatterjee, Satipati; Chatterjee, Pratima; Bandyopadhyay, Amit

    2006-01-01

    Childhood obesity is presently increasing worldwide and has created enormous concern for researchers working in the field of obesity related diseases with special interest in child health and development. Selected anthropometric measurements including stature, body mass, and skinfolds are globally accepted sensitive indicators of growth patterns and health status of a child. The present study was therefore aimed not only at evaluating the body mass index (BMI), skinfolds, body fat percentage (%fat) in obese school going boys of West Bengal, India, but also aimed to compare these data with their non-obese counterparts. Ten to sixteen year old obese boys (N = 158) were separated from their non-obese counterparts using the age-wise international cut-off points of BMI. Skinfolds were measured using skinfold calipers, BMI and %fat were calculated from standard equations. Body mass, BMI, skinfolds and %fat were significantly (Pimportance in order to identify or categorize obese boys, and to take preventative steps to minimise serious health problems that appear during the later part of life.

  16. Dorsal skinfold chamber models in mice

    Directory of Open Access Journals (Sweden)

    Schreiter, Jeannine

    2017-07-01

    Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter

  17. The Use of Skinfold to Estimate Body Fatness on Children and Youth.

    Science.gov (United States)

    Lohman, T. G.

    1987-01-01

    Concern about the body fat of children and its relation to adult obesity has led to the development of standards for assessing children's optimal body fat content. The use of skinfold thickness measures to establish the degree of fatness is described. (MT)

  18. Ecogeographical associations between climate and human body composition: analyses based on anthropometry and skinfolds.

    Science.gov (United States)

    Wells, Jonathan C K

    2012-02-01

    In the 19th century, two "ecogeographical rules" were proposed hypothesizing associations of climate with mammalian body size and proportions. Data on human body weight and relative leg length support these rules; however, it is unknown whether such associations are attributable to lean tissue (the heat-producing component) or fat (energy stores). Data on weight, height, and two skinfold thickness were obtained from the literature for 137 nonindustrialized populations, providing 145 male and 115 female individual samples. A variety of indices of adiposity and lean mass were analyzed. Preliminary analyses indicated secular increases in skinfolds in men but not women, and associations of age and height with lean mass in both sexes. Decreasing annual temperature was associated with increasing body mass index (BMI), and increasing triceps but not subscapular skinfold. After adjusting for skinfolds, decreasing temperature remained associated with increasing BMI. These results indicate that colder environments favor both greater peripheral energy stores, and greater lean mass. Contrasting results for triceps and subscapular skinfolds might be due to adaptive strategies either constraining central adiposity in cold environments to reduce cardiovascular risk, or favoring central adiposity in warmer environments to maintain energetic support of the immune system. Polynesian populations were analyzed separately and contradicted all of the climate trends, indicating support for the hypothesis that they are cold-adapted despite occupying a tropical region. It is unclear whether such associations emerge through natural selection or through trans-generational and life-course plasticity. These findings nevertheless aid understanding of the wide variability in human physique and adiposity. Copyright © 2011 Wiley Periodicals, Inc.

  19. Detecting overweight and obesity among young Syrian boys based on skinfold thickness

    Directory of Open Access Journals (Sweden)

    Al-Bachir Mahfouz

    2016-03-01

    Full Text Available There is no data on the prevalence of overweight and obesity in young Syrian boys. Therefore, the present study aimed to provide baseline and reference data on the prevalence of overweight and obesity among young Syrian boys using skin-fold thickness measurements and deuterium dilution (DD as a reference method. The sample of 2470 healthy Syrian 18- to 19-year-old boys were enrolled in this study. SFTs were measured at the biceps (B, triceps (T, subscapular (SI and suprailiac locations (SS were done and validated using the DD technique as a reference method. Receiver operating characteristics (ROC curve was drawn to determine appropriate cut-off points of the Σ2 limb SFT (T+B, Σ2 trunk SFT (SI+SS, Σ4 SFT (T+B+SI+SS and Log Σ4 SFT for defining overweight and obesity. The overall prevalence of overweight and obesity in young Syrian boys, based on biceps SFT, triceps SFT, subscapular SFT, suprailiac SFT, Σ2 limb SFT, Σ2 trunk SFT, Σ4 SFT, logarithm Σ4 SFT, and DDT were 35.3%, 32%, 31.6%, 14.8%, 32.9%, 26.6%, 28.1%, 24.1%, 46.5%, respectively. Strongly positive correlation was found between SFT and total body fat in adolescents. For diagnosing overweight on the basis of Σ2 limb SFT, Σ2 trunk SFT, Σ4 SFT and logarithm Σ4 SFT, we propose the following cut-off points: 17.25 mm, 23.50 mm, 39.25 mm and 1.60, respectively. To predict obesity, Σ2 limb SFT, Σ2 trunk SFT, Σ4 SFT and logarithm Σ4 SFT threshold were increased to 23.25 mm, 32.50 mm, 55.25 and 1.75, respectively. Basing on SFT clearly leads to underestimates of the prevalence of weight problems among young boys. SFT measurement screen missed 11.2 to 31.7% of overall overweight and obesity cases.

  20. Nuchal Skinfold Thickness: A Novel Parameter for Assessment of Body Composition in Childhood Craniopharyngioma

    Science.gov (United States)

    Sterkenburg, Anthe S.; Hoffmann, Anika; Reichel, Julia; Lohle, Kristin; Eveslage, Maria; Warmuth-Metz, Monika

    2016-01-01

    Context: Hypothalamic obesity, cardiovascular disease (CVD), and relapse/progression have a major impact on prognosis in childhood-onset craniopharyngioma (CP). We analyzed nuchal skinfold thickness (NST) on magnetic resonance imaging performed for follow-up monitoring as a novel parameter for body composition (BC) and CVD in CP. Objective: The objective of the study was to identify the association of NST with body mass index (BMI), waist to height ratio (WHtR), functional capacity, and blood pressure (BP) in CP and controls. Design: This was a cross-sectional and longitudinal prospective study in CP patients. Setting: The study was conducted at HIT-Endo, KRANIOPHARYNGEOM 2000/2007. Patients: Participants included 94 CP patients and 75 controls. Interventions: There were no interventions. Main Outcome Measures: Association of NST with BC and BP in 43 CP and 43 controls was measured. Results: NST correlated with BMI SD score (SDS; r = 0.78; P < .001; n = 169) and WHtR (r = 0.85; P < .001; n = 86) in the total cohort and CP patients (NST-BMI SDS: r = 0.77, P < .001, n = 94); NST-WHtR: r = 0.835, P < .001, n=43) and controls (NST-BMI SDS: r = 0.792, P < .001, n = 75; NST-WHtR: r = 0.671, P < .001, n = 43). In CP, systolic BP correlated with NST (r = 0.575, P < .001), BMI SDS (r = 0.434, P = .004), and WHtR (r = 0.386, P = .011). Similar results were observed for diastolic BP in CP. In multivariate analyses, NST had a predictive value for hypertension in postpubertal CP and controls (odds ratio 6.98, 95% confidence interval [1.65, 29.5], P = .008). During a longitudinal follow-up, changes in NST correlated with changes in BMI SDS (P < .001) and WHtR (P = .01) but not with changes in BP and functional capacity. Conclusions: Because monitoring of magnetic resonance imaging and BC is essential for follow-up in CP, NST could serve as a novel and clinically relevant parameter for longitudinal assessment of BC and CVD risk in CP. PMID:27680877

  1. Developing best practices teaching procedures for skinfold assessment: observational examination using the Think Aloud method.

    Science.gov (United States)

    Holmstrup, Michael E; Verba, Steven D; Lynn, Jeffrey S

    2015-12-01

    Skinfold assessment is valid and economical; however, it has a steep learning curve, and many programs only include one exposure to the technique. Increasing the number of exposures to skinfold assessment within an undergraduate curriculum would likely increase skill proficiency. The present study combined observational and Think Aloud methodologies to quantify procedural and cognitive characteristics of skinfold assessment. It was hypothesized that 1) increased curricular exposure to skinfold assessment would improve proficiency and 2) the combination of an observational and Think Aloud analysis would provide quantifiable areas of emphasis for instructing skinfold assessment. Seventy-five undergraduates with varied curricular exposure performed a seven-site skinfold assessment on a test subject while expressing their thoughts aloud. A trained practitioner recorded procedural observations, with transcripts generated from audio recordings to capture cognitive information. Skinfold measurements were compared with a criterion value, and bias scores were generated. Participants whose total bias fell within ±3.5% of the criterion value were proficient, with the remainder nonproficient. An independent-samples t-test was used to compare procedural and cognitive observations across experience and proficiency groups. Additional curricular exposure improved performance of skinfold assessment in areas such as the measurement of specific sites (e.g., chest, abdomen, and thigh) and procedural (e.g., landmark identification) and cognitive skills (e.g., complete site explanation). Furthermore, the Think Aloud method is a valuable tool for determining curricular strengths and weaknesses with skinfold assessment and as a pedagogical tool for individual instruction and feedback in the classroom. Copyright © 2015 The American Physiological Society.

  2. Shifting Patterns of BMI and Skinfold Fatness among US Children: 1985/87 vs. 2012

    Directory of Open Access Journals (Sweden)

    Yan Yang

    2016-12-01

    Full Text Available Background: Childhood obesity has been recognized as a major public health concern. The purpose of this study was to determine specific shifting patterns of BMI and skinfold fatness across different age and sex groups between 1985/87 and 2012. Methods: The data of 9,366 children aged 8-15 years from two nationally representative surveys, i.e., 1985/87 National Children and Youth Fitness Study I & II and 2012 National Health and Nutrition Examination Survey National Youth Fitness Survey, were analyzed. Specifically, changes of BMI-based obesity prevalence and shifting patterns of BMI, height, weight, skinfold body fat percentage (skinfold-fat%, subscapular skinfold, and triceps skinfold from 1985/87 to 2012 were estimated by age and sex using the 1985/87 quartiles as the baseline. Results: Significantly increased obesity prevalence were reconfirmed for both boys (12.12%, P <.001 and girls (3.53%, P <.001 from 1985/87 to 2012. Except for height, all other measures in 2012 experienced an unbalanced shifting pattern, mainly from other quartiles into the 4th quartile of 1985/87. Conclusion: The shifting of both boys’ and girls’ BMI and skinfold-fat% were all concentrated in the 4th quartile of 1985/87, indicating not only that there was a significant increase in BMI and skinfold-fat% in the U.S. children from 1985/87 to 2012, but also into the overweight and obese subgroups, which serves as a serious warning for childhood obesity epidemic and public health.

  3. Accuracy and Utility of Estimating Lean Body Mass and Nutritional Status in Patients with Chronic Kidney Disease on Long-Term Hemodialysis Using Anthropometric Skinfold Thickness Measurements.

    Science.gov (United States)

    Leong, Khai Gene; Chee, Jia Lian; Karahalios, Amalia; Skelley, Annabelle; Wong, Kim

    2018-01-01

    Malnutrition is common in patients on hemodialysis (prevalence of 30% to 50%) and is associated with higher mortality. Lean body mass (LBM) assessment is an accurate way of assessing nutritional status. The dual-energy X-ray absorptiometry (DEXA) scan is a reliable method in assessing body compositions and LBM; however, it is expensive and largely inaccessible. Anthropometric skinfold thickness measurement (ASFM) is useful in assessing LBM. It is cheaper and accessible, but underutilized clinically. The subjective global score (SGA) is a well-established method of assessing nutritional status. All three methods of assessing nutritional status were compared. In this pilot observational study, there was a significant correlation between LBM% estimated by DEXA and ASFM (mean difference -1.46% [95% CI -4.09 to 1.18]; LOA -14.0 to 11.1). Nutritional status by SGA could only detect those severely malnourished when using LBM% by ASFM as comparison. Our study demonstrated that ASFM is a useful method of assessing LBM and nutritional status, which can be easily utilized clinically. Copyright© by the American Nephrology Nurses Association.

  4. Biphasic response of subscapular skinfold thickness to hGH or IGF-1 administration to patients with congenital IGHD, congenital MPHD and Laron syndrome.

    Science.gov (United States)

    Bisker-Kassif, Orly; Kauli, Rivka; Lilos, Pearl; Laron, Zvi

    2014-01-01

    To evaluate changes in adiposity in congenital GH/IGF-1 deficient children during hGH or IGF-1 treatment. 27 children with congenital isolated growth hormone deficiency (cIGHD) treated with hGH for 2.5-€“15.2 years (mean 10.0 ± 3.4), 18 children with congenital multiple pituitary hormone deficiency (cMPHD), treated with hGH for 2.3-€“17.9 years (mean 6.1 ± 4.3), and 14 children with Laron syndrome (LS) treated with IGF-1 for 1.2-12 years (mean 5.5 ± 3.7) were studied. Changes in the degree of adiposity were evaluated by subscapular skinfold thickness (SSFT), before, during and up to 2 years after treatment. All the children had various degrees of obesity. During the pretreatment period, cIGHD patients showed little changes in SSFT (P = 0.45), cMPHD and LS patients showed an increase in SSFT (P = 0.01, P = 0.06 respectively). During the initial 0.6-1.1 years of hGH/IGF-1 treatment, the SSFT decreased in all 3 groups (P < 0.001), while during subsequent years a significant increase in SSFT (P < 0.001) was observed, in all types of patients, notably in females. Only the cIGHD patients demonstrated a significant correlation between the degree of SSFT decrease and height SDS gain (R = -ˆ’0.56, P = 0.002) in the first period of treatment. Short term replacement therapy of 0.6-€“1.1 years with either hGH or IGF-1, induced a reduction in subscapular subcutaneous fat whereas prolongation of therapy led to an increase in the subcutaneous fat. © 2014 Asian Oceanian Association for the Study of Obesity . Published by Elsevier Ltd. All rights reserved.

  5. Tongue thickness relates to nutritional status in the elderly.

    Science.gov (United States)

    Tamura, Fumiyo; Kikutani, Takeshi; Tohara, Takashi; Yoshida, Mitsuyoshi; Yaegaki, Ken

    2012-12-01

    Many elderly people under long-term care suffer from malnutrition caused by dysphagia, frequently leading to sarcopenia. Our hypothesis is that sarcopenia may compromise oral function, resulting in dysphagia. The objectives of this study were to evaluate sarcopenia of the lingual muscles by measuring the tongue thickness, and elucidate its relationship with nutritional status. We examined 104 elderly subjects (mean age = 80.3 ± 7.9 years). Anthropometric data, such as triceps skinfold thickness and midarm muscle area (AMA), were obtained. The tongue thickness of the central part was determined using ultrasonography. Measurement was performed twice and the mean value was obtained. The relationship between tongue thickness and nutritional status was analyzed by Pearson's correlation coefficient and Spearman's rank correlation coefficient. AMA and age were identified by multiple-regression analysis as factors influencing tongue thickness. The results of this study suggest that malnutrition may induce sarcopenia not only in the skeletal muscles but also in the tongue.

  6. Epidemiologia das pregas cutâneas triciptal e subescapular elevadas em adolescentes Epidemiology of elevated triciptal and subscapular skinfolds in adolescents

    Directory of Open Access Journals (Sweden)

    Rodrigo Pereira Duquia

    2008-01-01

    Full Text Available O objetivo deste estudo foi descrever e comparar as pregas cutâneas triciptal (PCT e subescapular (PCS de acordo com características demográficas, sócio-econômicas, comportamentais e biológicas em adolescentes de Pelotas, Rio Grande do Sul, Brasil. Realizou-se um estudo transversal aninhado a uma coorte de nascimentos (N = 4.452; média de idade = 11 anos. Os desfechos foram apresentar prega cutânea maior ou igual ao percentil 90 da curva de referência do National Center for Health Statistics. A prevalência de PCT e PCS elevada foi, respectivamente, de 20,2% e 17,3% nos meninos e de 14,2% e 10,5% nas meninas. O fator mais fortemente associado com adiposidade nos meninos foi o nível econômico (p The objective of this study was to describe and compare the tricipital (TSF and subscapular skinfold (SSF thickness according to demographic, socioeconomic, behavioral, and biological characteristics in adolescents from Pelotas, Rio Grande do Sul State, Brazil. A cross-sectional study nested in a birth cohort (n = 4,452; mean age = 11 years was conducted. The outcomes were defined as skinfold thickness > 90th percentile of the National Center for Health Statistics reference curve. The prevalence rates for elevated TSF and SSF were 20.2% and 17.3%, respectively, in boys and 14.2% and 10.5% in girls. The strongest factor associated with adiposity in boys was socioeconomic status (p < 0.001, whereas among girls it was maternal body mass index (p < 0.001. Low physical activity (< 300 minutes/week was associated with elevated SSF only among girls, while schooling was associated with increased TSF and SSF only among boys. Diet, skin color, and sedentary behavior were not associated with any of the outcomes. We concluded that the main predictors of adiposity were maternal and socioeconomic characteristics. We recommend that further studies on this issue apply other methods to estimate body composition in order to confirm our results.

  7. The dorsal skinfold chamber: window into the dynamic interaction of biomaterials with their surrounding host tissue

    Directory of Open Access Journals (Sweden)

    MW Laschke

    2011-09-01

    Full Text Available The implantation of biomaterials into the human body has become an indispensable part of almost all fields of modern medicine. Accordingly, there is an increasing need for appropriate approaches, which can be used to evaluate the suitability of different biomaterials for distinct clinical indications. The dorsal skinfold chamber is a sophisticated experimental model, which has been proven to be extremely valuable for the systematic in vivo analysis of the dynamic interaction of small biomaterial implants with the surrounding host tissue in rats, hamsters and mice. By means of intravital fluorescence microscopy, this chronic model allows for repeated analyses of various cellular, molecular and microvascular mechanisms, which are involved in the early inflammatory and angiogenic host tissue response to biomaterials during the initial 2-3 weeks after implantation. Therefore, the dorsal skinfold chamber has been broadly used during the last two decades to assess the in vivo performance of prosthetic vascular grafts, metallic implants, surgical meshes, bone substitutes, scaffolds for tissue engineering, as well as for locally or systemically applied drug delivery systems. These studies have contributed to identify basic material properties determining the biocompatibility of the implants and vascular ingrowth into their surface or internal structures. Thus, the dorsal skinfold chamber model does not only provide deep insights into the complex interactions of biomaterials with the surrounding soft tissues of the host but also represents an important tool for the future development of novel biomaterials aiming at an optimisation of their biofunctionality in clinical practice.

  8. Prevalence of Overweight and Obesity in Portuguese Adolescents: Comparison of Different Anthropometric Methods

    Science.gov (United States)

    Minghelli, Beatriz; Nunes, Carla; Oliveira, Raul

    2013-01-01

    Background: The recommended anthropometric methods to assess the weight status include body mass index (BMI), skinfold thickness, and waist circumference. However, these methods have advantages and disadvantages regarding the classification of overweight and obesity in adolescents. Aims: The study was to analyze the correlation between the measurements of BMI, skinfold thickness and waist circumference to assess overweight and obesity in Portuguese adolescents. Materials and Methods: A sample of 966 students of Portugal was used. Of them, 437 (45.2%) were males and 529 (54.8%) were females aged between 10 and 16 years. The evaluations included BMI calculation, skinfold thickness, and waist circumference measurements. Results: This study revealed a high prevalence of overweight and obesity with values ranging from 31.6%, 61.4%, and 41.1% according to the measurement of BMI, skinfold thickness, and waist circumference, respectively. The results found a high level of correlation between BMI and skinfold thickness (P < 0.001, r = 0.712), between BMI and waist circumference (P < 0.001, r = 0.884), and waist circumference and skinfold thickness (P < 0.001, r = 0.701). Conclusions: This study revealed a high prevalence of overweight and obesity in Portuguese adolescents using three different anthropometric methods, where the BMI showed the lowest values of prevalence of overweight and obesity and the skinfold thickness showed the highest values. The three anthropometric methods were highly correlated. PMID:24404544

  9. Anatomical fat patterning in male Nigerian soccer players | Adeniran ...

    African Journals Online (AJOL)

    Results showed that the midfielders had the least (13.5 ± 3.7 %), while the goalkeepers had the highest percentage body fat (16.8 ± 2.3 %). Skinfold values were found to vary by playing positions. Goalkeepers had the highest biceps skinfold thickness (7.2 ± 2.8 mm). Supra-iliac skinfold thickness was least in the defenders ...

  10. Anthropometric and training variables related to half-marathon running performance in recreational female runners.

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Rosemann, Thomas

    2011-05-01

    The relationship between skin-fold thickness and running has been investigated in distances ranging from 100 m to the marathon distance (42.195 km), with the exclusion of the half-marathon distance (21.0975 km). We investigated the association between anthropometric variables, prerace experience, and training variables with race time in 42 recreational, nonprofessional, female half-marathon runners using bi- and multivariate analysis. Body weight (r, 0.60); body mass index (r, 0.48); body fat percentage (r, 0.56); pectoral (r, 0.61), mid-axilla (r, 0.69), triceps (r, 0.49), subscapular (r, 0.61), abdominal (r, 0.59), suprailiac (r, 0.55), and medial calf (r, 0.53) skin-fold thickness; mean speed of the training sessions (r, -0.68); and personal best time in a half-marathon (r, 0.69) correlated with race time after bivariate analysis. Body weight (P = 0.0054), pectoral skin-fold thickness (P = 0.0068), and mean speed of the training sessions (P = 0.0041) remained significant after multivariate analysis. Mean running speed during training was related to mid-axilla (r, -0.31), subscapular (r, -0.38), abdominal (r, -0.44), and suprailiac (r, -0.41) skin-fold thickness, the sum of 8 skin-fold thicknesses (r, -0.36); and percent body fat (r, -0.31). It was determined that variables of both anthropometry and training were related to half-marathon race time, and that skin-fold thicknesses were associated with running speed during training. For practical applications, high running speed during training (as opposed to extensive training) may both reduce upper-body skin-fold thicknesses and improve race performance in recreational female half-marathon runners.

  11. Relationship between in utero sonographic evaluation and subcutaneous plicometry after birth in infants with intrauterine growth restriction: an exploratory study

    Directory of Open Access Journals (Sweden)

    Giannì Maria L

    2010-10-01

    Full Text Available Abstract Background Intrauterine growth restriction (IUGR is associated with several medical complications before and after delivery. The aim of this study was to evaluate the concordance between the fetal ultrasonographic measurement of subcutaneous tissue thicknesses and the skinfold thicknesses assessment in intrauterine growth restricted newborns. Methods We designed an exploratory study. Fetal ultrasonographic measurement of subcutaneous tissue thicknesses, according to Bernstein's and Galan's method, and neonatal skinfold thicknesses were evaluated in 13 intrauterine growth restricted newborns within 4 hours before delivery and on the first day of life, respectively. Concordance between fetal and neonatal measurements was assessed using the Lin's correlation coefficient and the Bland-Altman method. Results The data obtained by the measurements of neonatal skinfold thicknesses was significantly correlated with the prenatal measurements (Lin's coefficients, arm: 0.60; subscapular: 0.72; abdomen: 0.51. Bland-Altman analysis showed moderate agreement between the fetal ultrasonographic measurement of subcutaneous tissue thicknesses and the neonatal skinfold thicknesses assessment. Conclusions The present study provides preliminary evidence that fetal sonographic measurements may represent additional indices of intrauterine growth restriction.

  12. Predictor variables for half marathon race time in recreational female runners

    Directory of Open Access Journals (Sweden)

    Beat Knechtle

    2011-01-01

    Full Text Available INTRODUCTION: The relationship between skin-fold thickness and running performance has been investigated from 100 m to the marathon distance, except the half marathon distance. OBJECTIVE: To investigate whether anthropometry characteristics or training practices were related to race time in 42 recreational female half marathoners to determine the predictor variables of half-marathon race time and to inform future novice female half marathoners. METHODS: Observational field study at the 'Half Marathon Basel' in Switzerland. RESULTS: In the bivariate analysis, body mass (r = 0.60, body mass index (r = 0.48, body fat (r = 0.56, skin-fold at pectoral (r = 0.61, mid-axilla (r = 0.69, triceps (r = 0.49, subscapular (r = 0.61, abdominal (r = 0.59, suprailiac (r = 0.55 medial calf (r = 0.53 site, and speed of the training sessions (r = -0.68 correlated to race time. Mid-axilla skin-fold (p = 0.04 and speed of the training sessions (p = 0.0001 remained significant after multi-variate analysis. Race time in a half marathon might be predicted by the following equation (r² = 0.71: Race time (min = 166.7 + 1.7x (mid-axilla skin-fold, mm - 6.4x (speed in training, km/h. Running speed during training was related to skinfold thickness at mid-axilla (r = -0.31, subscapular (r = -0.38, abdominal (r = -0.44, suprailiacal (r = -0.41, the sum of eight skin-folds (r = -0.36 and percent body fat (r = -0.31. CONCLUSION: Anthropometric and training variables were related to half-marathon race time in recreational female runners. Skin-fold thicknesses at various upper body locations were related to training intensity. High running speed in training appears to be important for fast half-marathon race times and may reduce upper body skin-fold thicknesses in recreational female half marathoners.

  13. Predictor variables for half marathon race time in recreational female runners.

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Rosemann, Thomas; Lepers, Romuald

    2011-01-01

    The relationship between skin-fold thickness and running performance has been investigated from 100 m to the marathon distance, except the half marathon distance. To investigate whether anthropometry characteristics or training practices were related to race time in 42 recreational female half marathoners to determine the predictor variables of half-marathon race time and to inform future novice female half marathoners. Observational field study at the 'Half Marathon Basel' in Switzerland. In the bivariate analysis, body mass (r = 0.60), body mass index (r = 0.48), body fat (r = 0.56), skin-fold at pectoral (r = 0.61), mid-axilla (r = 0.69), triceps (r = 0.49), subscapular (r = 0.61), abdominal (r = 0.59), suprailiac (r = 0.55) medial calf (r = 0.53) site, and speed of the training sessions (r = -0.68) correlated to race time. Mid-axilla skin-fold (p = 0.04) and speed of the training sessions (p = 0.0001) remained significant after multi-variate analysis. Race time in a half marathon might be predicted by the following equation (r² = 0.71): Race time (min) = 166.7 + 1.7x (mid-axilla skin-fold, mm) - 6.4x (speed in training, km/h). Running speed during training was related to skinfold thickness at mid-axilla (r = -0.31), subscapular (r = -0.38), abdominal (r = -0.44), suprailiacal (r = -0.41), the sum of eight skin-folds (r = -0.36) and percent body fat (r = -0.31). Anthropometric and training variables were related to half-marathon race time in recreational female runners. Skin-fold thicknesses at various upper body locations were related to training intensity. High running speed in training appears to be important for fast half-marathon race times and may reduce upper body skin-fold thicknesses in recreational female half marathoners.

  14. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    International Nuclear Information System (INIS)

    Newby, M.J.; Keim, N.L.; Brown, D.L.

    1990-01-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg less lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients

  15. Assessment of nutritional status in adult patients with cystic fibrosis: whole-body bioimpedance vs body mass index, skinfolds, and leg-to-leg bioimpedance

    NARCIS (Netherlands)

    Hollander, F.M.; Roos, de N.M.; Vries, de J.H.M.; Berkhout, van F.T.

    2005-01-01

    Objective: To investigate whether body mass index (BMI) or body fat percentage estimated from BMI, skinfolds, or leg-to-leg bioimpedance are good indicators of nutritional status in adult patients with cystic fibrosis. Body fat percentage measured by whole-body bioimpedance was used as the reference

  16. Body composition of italian female hockey players

    Directory of Open Access Journals (Sweden)

    P Pavan

    2009-07-01

    Full Text Available Objective: In this work the anthropometric features and the body composition of Italian hockey players, members of the Female National team, were analysed. The purpose of the research was to verify if morphological features could influence the performance of different positional groups. Materials and Methods: Each player was measured for her total and sitting height, weight, 9 skinfolds thickness and bioelectrical impedance analysis. Different equations were used to calculate the Fat% from skinfolds thickness. Results: Average height is not a crucial advantage for this sport. On the contrary the proportion trunk-limb seems to play an important role for the performance of the midfield players. Percentage of body fat of the hockey players was lower than the Fat% of the non-athletes women of the same age. Significant differences were found between Fat% determined by skinfolds thickness and Fat% obtained by bioelectrical impedance analysis. Conclusions: The results of this study indicate that there are significant differences in anthropometric features and in body composition between positional groups, stressing the importance of a specific training program. Keywords: field hockey, bioelectrical impedance, skinfolds thickness, anthropometry.

  17. The effect of hypocaloric diet enriched in legumes with or without L-arginine and selenium on anthropometric measures in central obese women

    Science.gov (United States)

    Alizadeh, Mohammad; Daneghian, Sevana; Ghaffari, Aida; Ostadrahimi, Alireza; Safaeiyan, Abdolrasoul; Estakhri, Rassul; Gargari, Bahram Pourghasem

    2010-01-01

    BACKGROUND: Identifying new ways to decrease adiposity will be very valuable for health. The aim of this study was to find out whether L-Arginine (Arg) and selenium alone or together can increase the effect of hypocaloric diet enriched in legumes (HDEL) on anthropometric measures in healthy obese women. METHODS: This randomized, double-blind, placebo-controlled trial was undertaken in 84 healthy premenopausal women with central obesity. After 2 weeks of run-in on an isocaloric diet, participants were randomly considered to eat HDEL, Arg (5 g/d) and HDEL, selenium (200 µg/d) and HDEL or Arg, selenium and HDEL for 6 weeks. The following variables were assessed before intervention and 3 and 6 weeks after it: weight, waist circumference, hip circumference, waist to hip ratio (WHR), body mass index (BMI), and fasting nitrite/nitrate (NOx) concentrations. Other variables (arm, thigh, calf and breast circumferences, subscapular, triceps, biceps and suprailiac skinfold thicknesses, sum of skinfold thicknesses (SSF), body density (D) and estimated percent of body fat (EPF)) were assessed before and after intervention. RESULTS: HDEL showed a significant effect in reduction of waist, hip, arm, thigh, calf and breast circumferences, triceps, biceps, subscapular and suprailiac skinfold thicknesses, WHR, SSF, D and EPF. HDEL + Arg + selenium significantly reduced suprailiac skinfold thicknesses; and there was no significant effect of HDEL, Arg, selenium and Arg plus selenium on weight, BMI and fasting NOx. CONCLUSIONS: The study indicates that HDEL + Arg + selenium reduce suprailiac skinfold thicknesses which represents the abdominal obesity reduction. PMID:21526106

  18. The effect of hypocaloric diet enriched in legumes with or without L- arginine and selenium on anthropometric measures in central obese women

    Directory of Open Access Journals (Sweden)

    Mohammad Alizadeh

    2010-01-01

    Full Text Available Background: Identifying new ways to decrease adiposity will be very valuable for health. The aim of this study was to find out whether L- Arginine (Arg and selenium alone or together can increase the effect of hypocaloric diet enriched in legumes (HDEL on anthropometric measures in healthy obese women. Methods: This randomized, double- blind, placebo- controlled trial was undertaken in 84 healthy premenopausal women with central obesity. After 2 weeks of run- in on an isocaloric diet, participants were randomly considered to eat HDEL, Arg (5 g/d and HDEL, selenium (200 μg/d and HDEL or Arg, selenium and HDEL for 6 weeks. The following variables were assessed before intervention and 3 and 6 weeks after it: weight, waist circumference, hip circumference, waist to hip ratio (WHR, body mass index (BMI, and fasting nitrite/nitrate (NOx concentrations. Other variables (arm, thigh, calf and breast circumferences, subscapular, triceps, biceps and suprailiac skinfold thicknesses, sum of skinfold thicknesses (SSF, body density (D and estimated percent of body fat (EPF were assessed before and after intervention. Results: HDEL showed a significant effect in reduction of waist, hip, arm, thigh, calf and breast circumferences, triceps, biceps, subscapular and suprailiac skinfold thicknesses, WHR, SSF, D and EPF. HDEL + Arg + selenium significantly reduced suprailiac skinfold thicknesses; and there was no significant effect of HDEL, Arg, selenium and Arg plus selenium on weight, BMI and fasting NOx . Conclusions: The study indicates that HDEL + Arg + selenium reduce suprailiac skinfold thicknesses which represents the abdominal obesity reduction.

  19. Caffeine Intake During Pregnancy in Different Intrauterine Environments and its Association with Infant Anthropometric Measurements at 3 and 6 Months of Age.

    Science.gov (United States)

    de Medeiros, Thamíris Santos; Bernardi, Juliana Rombaldi; de Brito, Mariana Lopes; Bosa, Vera Lucia; Goldani, Marcelo Zubaran; da Silva, Clécio Homrich

    2017-06-01

    Objective To investigate the association between maternal caffeine intake during pregnancy and infant anthropometric measurements at age 3 and 6 months. Methods Longitudinal observational study of mother-child pairs stratified into five groups: diabetic women (DM), hypertensive women (HYP), smoking mothers (SMO), mothers of infants small for gestational age (SGA), and controls (CTL). Pairs were recruited from three public hospitals in Porto Alegre, Brazil, from 2011 to 2015, using a convenience sampling strategy. The Food Frequency Questionnaire (FFQ) was administered on postpartum day 7 to evaluate maternal caffeine intake during pregnancy. The anthropometric measurements of interest (weight, length, and skinfold thickness) were assessed at birth and at age 3 and 6 months. Linear regression was used to analyze the interaction between caffeine intake and skinfold thickness. Results Overall, 272 mother-child pairs were investigated (41 DM, 26 HYP, 68 SMO, 25 SGA, and 112 CTL). There were no differences in anthropometric measurements between infants born to mothers who had and had not consumed caffeine during pregnancy (P > 0.05). Children of mothers in the DM group had the highest adjusted average skinfold thicknesses at 3 months. An interaction between maternal caffeine intake during pregnancy and the sum of skinfolds at age 3 months was found in the DM and CTL groups (P caffeine intake influenced infants skinfold thickness measurements at 3 months of age. This parameter was reduced in infants born to mothers with DM and increased in those born to healthy control mothers.

  20. Anthropometry and physical activity level in the prediction of metabolic syndrome in children.

    Science.gov (United States)

    Andaki, Alynne Christian Ribeiro; Tinôco, Adelson Luiz Araújo; Mendes, Edmar Lacerda; Andaki Júnior, Roberto; Hills, Andrew P; Amorim, Paulo Roberto S

    2014-10-01

    To evaluate the effectiveness of anthropometric measures and physical activity level in the prediction of metabolic syndrome (MetS) in children. Cross-sectional study with children from public and private schools. Children underwent an anthropometric assessment, blood pressure measurement and biochemical evaluation of serum for determination of TAG, HDL-cholesterol and glucose. Physical activity level was calculated and number of steps per day obtained using a pedometer for seven consecutive days. Viçosa, south-eastern Brazil. Boys and girls (n 187), mean age 9·90 (SD 0·7) years. Conicity index, sum of four skinfolds, physical activity level and number of steps per day were accurate in predicting MetS in boys. Anthropometric indicators were accurate in predicting MetS for girls, specifically BMI, waist circumference measured at the narrowest point and at the level of the umbilicus, four skinfold thickness measures evaluated separately, the sum of subscapular and triceps skinfold thickness, the sum of four skinfolds and body fat percentage. The sum of four skinfolds was the most accurate method in predicting MetS in both genders.

  1. Determination of abdominal fat thickness using dual electrode separation in the focused impedance method (FIM)

    International Nuclear Information System (INIS)

    Surovy, Nusrat Jahan; Billah, Md Masum; Haowlader, Salahuddin; Al-Quaderi, Golam Dastegir; Rabbani, K Siddique-e

    2012-01-01

    Subcutaneous fat layer thickness in the abdomen is a risk indicator of several diseases and disorders like diabetes and heart problems and could be used as a measure of fitness. Skinfold measurement using mechanical calipers is simple but prone to error. Ultrasound scanning techniques are yet to be established as accurate methods for this purpose. magnetic resonance imaging (MRI) and computed tomography (CT) scans can provide the answer but are expensive and not available widely. Some initiatives were made earlier to use electrical impedance to this end, but had inadequacies. In the first part of this paper, a 4-electrode focused impedance method (FIM) with different electrode separations has been studied for its possible use in the determination of abdominal fat thickness in a localized region. For this, a saline phantom was designed to provide different electrode separations and different layers of resistive materials adjacent to the electrodes. The background saline simulated the internal organs having low impedance while the resistive layers simulated the subcutaneous fat. The plot of the measured impedance with electrode separation had different ‘slopes’ for different thicknesses of resistive layers, which offered a method to obtain an unknown thickness of subcutaneous fat layer. In the second part, measurements were performed on seven human subjects using two electrode separations. Fat layer thickness was measured using mechanical calipers. A plot of the above ‘slope’ against fat thickness could be fitted using a straight line with an R 2 of 0.93. Then this could be used as a calibration curve for the determination of unknown fat thickness. Further work using more accurate CT and MRI measurements would give a better calibration curve for practical use of this non-invasive and low-cost technique in abdominal fat thickness measurement. (paper)

  2. Exercise effects on fitness, lipids, glucose tolerance and insulin levels in young adults.

    Science.gov (United States)

    Israel, R G; Davidson, P C; Albrink, M J; Krall, J M

    1981-07-01

    The effect of 3 different physical training programs on cardiorespiratory (cr) fitness, fasting plasma lipids, glucose and insulin levels, and scapular skinfold thickness was assessed in 64 healthy college men. Training sessions were held 4 times a week for 5 weeks. The cr fitness improved significantly and skinfold thickness decreased following the aerobic, the pulse workout (interval training), and the anaerobic training compared to the control group. Skinfold thickness, plasma insulin, and triglyceride concentrations were significantly intercorrelated before and after training. The exercise programs had no significant effect on plasma cholesterol, triglycerides, phospholipids, glucose tolerance, or insulin levels. Change in adipose mass was thus dissociated from change in plasma insulin and triglyceride concentrations. It was concluded that in young men plasma triglycerides, the lipid component mostly readily reduced by exercise, were too low to be reduced further by a physical training program.

  3. High prevalence of malnutrition among patients with solid non-hematological tumors as found by using skinfold and circumference measurements

    Directory of Open Access Journals (Sweden)

    Adriana Garófolo

    Full Text Available CONTEXT AND OBJECTIVE: Malnutrition in cancer patients has many causes. Nutritional status is usually assessed from weight/height indices. These present limitations for the nutritional assessment of cancer patients: their weights include tumor mass, and lean mass changes are not reflected in weight/height indices. The objective was to evaluate differences between two anthropometric methods and compare deficits, in non-hematological tumor patients and hematological disease patients. DESIGN AND SETTING: Cross-sectional study at Instituto de Oncologia Pediátrica, Universidade Federal de São Paulo. METHODS: Children and adolescents were evaluated between March 1998 and January 2000. Traditional anthropometric measurements were obtained in the first month of treatment (induction therapy, by weight-for-height (W/H using z-scores index for children and body mass index (BMI for adolescents. Body composition evaluations consisted of specific anthropometric measurements: triceps skinfold thickness (TSFT, mid-upper arm circumference (MUAC and arm muscle circumference (AMC. Data were analyzed to compare nutritional assessment methods for diagnosing malnutrition prevalence. The chi-squared test was used for comparative analyses between tumor patients and hematological disease patients. RESULTS: Analysis was done on 127 patients with complete data. Higher percentages of deficits were found among tumor patients, by W/H z-scores or BMI and by MUAC and AMC. Higher percentages of deficits were shown by TSFT (40.2% and MUAC (35.4% than by W/H z-scores or BMI (18.9%. CONCLUSION: Non-hematological tumor patients presented higher malnutrition prevalence than did hematological disease patients. Body composition measurements by TSFT and MUAC detected more patients with malnutrition than did W/H or BMI.

  4. Impact of nutrition education and medical supervision on pregnancy outcome.

    Science.gov (United States)

    Sachdeva, R; Mann, S K

    1993-11-01

    Sixty Punjabi women from low and lower middle income groups were selected from eight villages of Ludhiana district. The supplements of iron, folic acid and calcium in the form of Folifer and Calcium Sandoz tablets were regularly supplied to experimental (E) group from second trimester onwards. A pamphlet about the diet during pregnancy was distributed to the E group along with four individual and three group contacts during the second half of pregnancy. The control (C) group was provided iron and folate supplements as per Government practice. Body height, weight, mid-upper arm circumference (MUA) and skinfold thickness of the subjects were recorded. Weight gained during pregnancy and post partum weight were also recorded and body mass index was calculated. In addition, crown heel length (CHL), birth weight (BW), skinfold thickness, MUA, head circumference (HC), Chest circumference (CC) and ponderal index (PI) of the neonates were recorded within eight hours of their birth. The gain in weight during pregnancy was 6.30 and 5.7 kg in E and C groups respectively. The study revealed that BW, CHL, skinfold thickness and PI of the newborns were significantly (p < 0.01) higher in E group. The mean BW of newborns in E and C groups was 2700 g and 2300 g, respectively. Weight gained during pregnancy had significant (p < 0.05) correlation to MUA, BW and skinfold thickness of the newborn.

  5. Different factors associate with body image in adolescence than in emerging adulthood: A gender comparison in a follow-up study

    Directory of Open Access Journals (Sweden)

    Sunna Gestsdottir

    2017-11-01

    Full Text Available Background Body image dissatisfaction has been linked with a range of adverse psychosocial outcomes in both genders and has become an important public health issue. Across all ages, women have reported being more dissatisfied with their bodies than men. The aim of the current study was to examine if fitness and physical activity associate with body image satisfaction differently across gender and age, measured in the same participants. Participants and procedure Participants were measured initially at age 15 years (N = 385 and again at age 23 years (N = 201. Structural equation modelling was used to examine the association between body image satisfaction, fitness, and physical activity. Covariates included skinfold thickness, body mass index, socioeconomic status, anxiety, and depression. Results Fitness and physical activity declined during the study period, body mass index increased, but no changes were found in body image satisfaction, depression, anxiety, or skinfold thickness. For women at ages 15 and 23 years, self-reported fitness and depression were found to be related to body image satisfaction, including body mass index at the age of 23 years. For 15-year-old men, skinfold thickness and aerobic fitness related to body image satisfaction, whereas skinfold thickness, depression, body mass index, and self-reported fitness did so at age 23 years. Conclusions Results suggest that different approaches are needed across gender to improve body image in adolescence whereas more similar ones can be used in emerging adulthood.

  6. Neuronal genes for subcutaneous fat thickness in human and pig are identified by local genomic sequencing and combined SNP association study.

    Directory of Open Access Journals (Sweden)

    Kyung-Tai Lee

    2011-02-01

    Full Text Available Obesity represents a major global public health problem that increases the risk for cardiovascular or metabolic disease. The pigs represent an exceptional biomedical model related to energy metabolism and obesity in humans. To pinpoint causal genetic factors for a common form of obesity, we conducted local genomic de novo sequencing, 18.2 Mb, of a porcine QTL region affecting fatness traits, and carried out SNP association studies for backfat thickness and intramuscular fat content in pigs. In order to relate the association studies in pigs to human obesity, we performed a targeted genome wide association study for subcutaneous fat thickness in a cohort population of 8,842 Korean individuals. These combined association studies in human and pig revealed a significant SNP located in a gene family with sequence similarity 73, member A (FAM73A associated with subscapular skin-fold thickness in humans (rs4121165, GC-corrected p-value  = 0.0000175 and with backfat thickness in pigs (ASGA0029495, p-value  = 0.000031. Our combined association studies also suggest that eight neuronal genes are responsible for subcutaneous fat thickness: NEGR1, SLC44A5, PDE4B, LPHN2, ELTD1, ST6GALNAC3, ST6GALNAC5, and TTLL7. These results provide strong support for a major involvement of the CNS in the genetic predisposition to a common form of obesity.

  7. Effect of strength training and short-term detraining on muscle mass in women aged over 50 years old

    Directory of Open Access Journals (Sweden)

    Maryam Delshad

    2013-01-01

    Full Text Available Background: The loss of muscle mass is associated with aging. The aim of this study was to determine the effects of resistance training and detraining on muscle mass in elderly women. Methods: Twenty post-menopausal women aged ≥50 years old were enrolled. Matching for age, they were randomly assigned into control and resistance training group (RT. The intervention consisted of three sets of 10 repetitions for 10 movements with Thera-Band tubing (based on 80-100% 10-RM, three times a week, for 12 weeks and thereafter, four weeks detraining. Skinfold thickness was determined by caliper. Percentage of body fat was estimated from skinfold thickness (triceps and subscapular by McArdle method. Fat mass (FM and fat-free mass (FFM were calculated. Range of motion for trunk flexion and extension was determined. Results: During 12 weeks of intervention, significant increases were observed in 1-RM of biceps curl, FFM, trunk flexion and extension and significant decreases during four weeks detraining in RT group. The RT group demonstrated significant decreases during resistance training and increases during detraining in skinfold thickness. FFM, trunk flexion, and extension decreased and skinfold thickness, %FM, and weight of body fat increased in the control group (P < 0.05. Conclusions: Resistance training with Thera-Band enhanced strength and muscle endurance in elderly women and a 4-week detraining period had an adverse effect on muscle power. This suggests that a strength training program is an effective intervention to prevent functional reductions, and can contribute to improve neuromuscular function in older adults.

  8. Skinfold creep under load of caliper. Linear visco- and poroelastic model simulations.

    Science.gov (United States)

    Nowak, Joanna; Nowak, Bartosz; Kaczmarek, Mariusz

    2015-01-01

    This paper addresses the diagnostic idea proposed in [11] to measure the parameter called rate of creep of axillary fold of tissue using modified Harpenden skinfold caliper in order to distinguish normal and edematous tissue. Our simulations are intended to help understanding the creep phenomenon and creep rate parameter as a sensitive indicator of edema existence. The parametric analysis shows the tissue behavior under the external load as well as its sensitivity to changes of crucial hydro-mechanical tissue parameters, e.g., permeability or stiffness. The linear viscoelastic and poroelastic models of normal (single phase) and oedematous tissue (twophase: swelled tissue with excess of interstitial fluid) implemented in COMSOL Multiphysics environment are used. Simulations are performed within the range of small strains for a simplified fold geometry, material characterization and boundary conditions. The predicted creep is the result of viscosity (viscoelastic model) or pore fluid displacement (poroelastic model) in tissue. The tissue deformations, interstitial fluid pressure as well as interstitial fluid velocity are discussed in parametric analysis with respect to elasticity modulus, relaxation time or permeability of tissue. The creep rate determined within the models of tissue is compared and referred to the diagnostic idea in [11]. The results obtained from the two linear models of subcutaneous tissue indicate that the form of creep curve and the creep rate are sensitive to material parameters which characterize the tissue. However, the adopted modelling assumptions point to a limited applicability of the creep rate as the discriminant of oedema.

  9. The contribution of fat component to gestational weight gain

    Directory of Open Access Journals (Sweden)

    2013-12-01

    Full Text Available Objective: to estimate the role of adipose tissue in gestational weight gain (GWG and preferential fat deposition among normal-weight women. Subjects and methods: prospective cohort study of 84 pregnancies: maternal body mass index 18,5–24,9 kg/m2, singleton term pregnancy, nondiabetic women, somatically well. GWG and skinfold thickness were evaluated in the 1st, 2nd, 3d trimesters, on the 3d day after delivery. Results: fat mass gain in low GWG was similar to recommended GWG and in the high-GWG group was greater one. Women with recommended and low GWG returned to their initial fat level on the 3d day after delivery, in excessive weight gain fat significantly increased (р=0,025. Compared to initial recommended GWG resulted in triceps skinfold thicknesses loss (р=0,001, in abdominal skinfold gained nothing and in thighs skinfold thicknesses increasing (р=0,021. Inadequate GWG leads to fat loss in arms (р=0,017, fat of abdominal area and thighs return to initial level. In excessive GWG fat in the upper trunk and arms not changed, in the lower area (thighs significantly increased compared to initial level (р=0,001 or other groups (р=0,001. Conclusion: excessive GWG was associated with greater adipose tissue cumulation and its deposition preferentially over the thighs. Inadequate GWG was clearly linked to low fat-free mass gain.

  10. Associations of out of school physical activity, sedentary lifestyle and socioeconomic status with weight status and adiposity of Cameroon children.

    Science.gov (United States)

    Navti, Lifoter K; Atanga, Mary B; Niba, Loveline L

    2017-01-01

    Low physical activity and a sedentary lifestyle are contributing to overweight/obesity in children. This study aims to explore relationships between out of school physical activity, sedentary lifestyle and socioeconomic status indicators with children's weight status and adiposity. Five hundred twenty-two children of ages 5 to 12 years were randomly selected in a school-based cross sectional study in Bamenda, Cameroon. Weight and height were measured and BMI calculated. These variables were standardized for age and gender. Socioeconomic variables and proxy measures of physical activity and sedentary lifestyle of children were reported by parents using a structured questionnaire. Bivariate and multivariable logistic regression was used to calculate odds ratios.Quantile regression was used to compare median values of triceps skinfold thickness across the different factors. In bivariate analysis, physical activity > 4 - 7 times/week was significantly ( p  = 0.010) associated with a lower prevalence (5.9%) of overweight/obesity. In multivariable analysis, physical activity > twice a week (OR 0.1, 95% CI 0.05 - 0.3), sedentary lifestyle > 3 h/day (OR 2.4, 95% CI 1.2 - 4.3) and being in the high occupation class (OR 4.3, 95% CI 2.2 - 8.1) independently predicted overweight/obesity. With quantile regression, physical activity > 4 - 7 times/week was significantly ( p  = 0.023) associated with a 1.36 mm decrease in median triceps skinfold thickness, while sedentary lifestyle (> 3 h/day) ( p  = 0.026) and being in the high occupation class ( p  = 0.007) were significantly associated with a 1.37 mm and 1.86 mm increase in median triceps skinfold thickness respectively. Physical activity is inversely related to BMI-defined overweight/obesity and triceps skinfold thickness. Also, a high sedentary lifestyle and a high occupation class were associated with overweight/obesity and had the largest significant relationship with triceps skinfold thickness

  11. Associations of infant subcutaneous fat mass with total and abdominal fat mass at school-age. The Generation R Study

    Science.gov (United States)

    Santos, Susana; Gaillard, Romy; Oliveira, Andreia; Barros, Henrique; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Jaddoe, Vincent WV

    2017-01-01

    Background Skinfold thickness enables the measurement of overall and regional subcutaneous fatness in infancy and may be associated with total and abdominal body fat in later childhood. We examined the associations of subcutaneous fat in infancy with total and abdominal fat at school-age. Methods In a population-based prospective cohort study among 821 children, we calculated total subcutaneous fat (sum of biceps, triceps, suprailiacal and subscapular skinfold thicknesses) and central-to-total subcutaneous fat ratio (sum of suprailiacal and subscapular skinfold thicknesses/total subcutaneous fat) at 1.5 and 24 months. At 6 years, we measured fat mass index (total fat/height3), central-to-total fat ratio (trunk fat/total fat) and android-to-gynoid fat ratio (android fat/gynoid fat) by dual-energy X-ray absorptiometry and preperitoneal fat mass area by abdominal ultrasound. Results Central-to-total subcutaneous fat ratio at 1.5 months was positively associated with fat mass index and central-to-total fat ratio at 6 years, whereas both total and central-to-total subcutaneous fat ratio at 24 months were positively associated with all childhood adiposity measures (pfat at 24 months was associated with an increased risk of childhood overweight (Odds Ratio 1.70 [95% Confidence Interval 1.36, 2.12]). These associations were weaker than those for body mass index and stronger among girls than boys. Conclusions Subcutaneous fat in infancy is positively associated with total and abdominal fat at school-age. Our results also suggest that skinfold thicknesses add little value to estimate later body fat, as compared to body mass index. PMID:27225335

  12. Associations of Infant Subcutaneous Fat Mass with Total and Abdominal Fat Mass at School-Age: The Generation R Study.

    Science.gov (United States)

    Santos, Susana; Gaillard, Romy; Oliveira, Andreia; Barros, Henrique; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Jaddoe, Vincent W V

    2016-09-01

    Skinfold thickness enables the measurement of overall and regional subcutaneous fatness in infancy and may be associated with total and abdominal body fat in later childhood. We examined the associations of subcutaneous fat in infancy with total and abdominal fat at school-age. In a population-based prospective cohort study among 821 children, we calculated total subcutaneous fat (sum of biceps, triceps, suprailiacal, and subscapular skinfold thicknesses) and central-to-total subcutaneous fat ratio (sum of suprailiacal and subscapular skinfold thicknesses/total subcutaneous fat) at 1.5 and 24 months. At 6 years, we measured fat mass index (total fat/height(3) ), central-to-total fat ratio (trunk fat/total fat), and android-to-gynoid fat ratio (android fat/gynoid fat) by dual-energy X-ray absorptiometry and preperitoneal fat mass area by abdominal ultrasound. Central-to-total subcutaneous fat ratio at 1.5 months was positively associated with fat mass index and central-to-total fat ratio at 6 years, whereas both total and central-to-total subcutaneous fat ratio at 24 months were positively associated with all childhood adiposity measures. A 1-standard-deviation scores higher total subcutaneous fat at 24 months was associated with an increased risk of childhood overweight (odds ratio 1.70, 95% confidence interval 1.36, 2.12). These associations were weaker than those for body mass index and stronger among girls than boys. Subcutaneous fat in infancy is positively associated with total and abdominal fat at school-age. Our results also suggest that skinfold thicknesses add little value to estimate later body fat, as compared with body mass index. © 2016 John Wiley & Sons Ltd.

  13. Biometrical characteristics and physiological responses to a local cold exposure of the extremities.

    Science.gov (United States)

    Savourey, G; Sendowski, I; Bittel, J

    1996-01-01

    The aim of this study was firstly to describe the physiological responses observed in 19 subjects during immersion of the arm up to the elbow in water at 5 degrees C (5 min) followed by a 10-min recovery and secondly, to correlate the observed physiological responses with biometrical characteristics of the subjects (maximal oxygen uptake, VO2max, percentage fat content of whole body, BF, and arm, forearm and hand skinfold thickness). The results showed that the time courses of changes in forearm and hand skin temperature were different compared to those of finger skin temperatures both during local cooling and during rewarming (P immersion, decreased hand skin temperature was correlated to VO2max (r = 0.45, P < or = 0.05) whereas decreased forearm skin temperature was correlated both to VO2max (r = 0.44, P < or = 0.05) and to skinfold thickness (r = -0.44, P < or = 0.05) but not to BF. During the beginning of the recovery period only, outside, inside forearm and hand skin temperatures were related to VO2max (r = 0.54, P < or = 0.05; r = 0.66, P < or = 0.01 and r = 0.45, P < or = 0.05, respectively) and all the skinfold thicknesses (r = -0.47 to -0.71, P < or = 0.05). It was concluded that the local skin temperature profiles differed according to the upper limb segment both during cooling and during early rewarming. Moreover, VO2max and upper limb skinfold thickness but not BF did influence the forearm and hand skin temperature changes during cooling and early rewarming but not the finger skin temperature changes and cardiovascular responses.

  14. Is total lymphocyte count related to nutritional markers in hospitalized older adults?

    Directory of Open Access Journals (Sweden)

    Vânia Aparecida LEANDRO-MERHI

    Full Text Available ABSTRACT BACKGROUND Older patients are commonly malnourished during hospital stay, and a high prevalence of malnutrition is found in hospitalized patients aged more than 65 years. OBJECTIVE To investigate whether total lymphocyte count is related to other nutritional markers in hospitalized older adults. METHODS Hospitalized older adults (N=131 were recruited for a cross-sectional study. Their nutritional status was assessed by the Nutritional Risk Screening (NRS, anthropometry, and total lymphocyte count. The statistical analyses included the chi-square test, Fisher's exact test, and Mann-Whitney test. Spearman's linear correlation coefficient determined whether total lymphocyte count was correlated with the nutritional markers. Multiple linear regression determined the parameters associated with lymphocyte count. The significance level was set at 5%. RESULTS According to the NRS, 41.2% of the patients were at nutritional risk, and 36% had mild or moderate depletion according to total lymphocyte count. Total lymphocyte count was weakly correlated with mid-upper arm circumference (r=0.20507; triceps skinfold thickness (r=0.29036, and length of hospital stay (r= -0.21518. Total lymphocyte count in different NRS categories differed significantly: older adults who were not at nutritional risk had higher mean and median total lymphocyte count ( P =0.0245. Multiple regression analysis showed that higher lymphocyte counts were associated with higher triceps skinfold thicknesses and no nutritional risk according to the NRS. CONCLUSION Total lymphocyte count was correlated with mid-upper arm circumference, triceps skinfold thickness, and nutritional risk according to the NRS. In multiple regression the combined factors that remained associated with lymphocyte count were NRS and triceps skinfold thickness. Therefore, total lymphocyte count may be considered a nutritional marker. Other studies should confirm these findings.

  15. [Development of weight-estimation formulae for the bedridden elderly requiring care].

    Science.gov (United States)

    Oonishi, Reiko; Fujii, Kouji; Tsuda, Hiroko; Imai, Katsumi

    2012-01-01

    Bedridden elderly persons requiring care need special body-weight measurement implements, and body-weighting assumes more difficult if they live at their own homes. Therefore, we tried to design a new weight-estimation formulae using various anthropometric variables. The subjects were 33 male and 132 female elderly inpatients certified to be at care level 4 or 5. The body composition included height, body weight, arm circumference, triceps skinfold thickness, subscapular skinfold thickness, calf circumference, and waist circumference. We studied the correlation between the body weight and each anthropometric variable and age. In men, the highest correlation with body weight was shown by waist circumference (r=0.891, pbedridden elderly patients requiring care.

  16. Associations Between Cardiorespiratory Fitness and Overweight With Academic Performance in 12-Year-Old Brazilian Children.

    Science.gov (United States)

    de Almeida Santana, Carla Caroliny; Farah, Breno Quintella; de Azevedo, Liane Beretta; Hill, James O; Gunnarsdottir, Thrudur; Botero, João Paulo; do Prado, Edna Cristina; do Prado, Wagner Luiz

    2017-05-01

    Obesity has been associated with poor academic achievement, while cardiorespiratory fitness (CRF) has been linked to academic success. To investigate whether CRF is associated with academic performance in Brazilian students, independently of body mass index (BMI), fatness and socioeconomic status (SES). 392 5th and 6th grade students (193 girls) (12.11 ± 0.75 years old) were evaluated in 2012. Skinfold thickness measures were performed, and students were classified according to BMI-percentile. CRF was estimated by a 20-meter shuttle run test, and academic achievement by standardized math and Portuguese tests. Multiple linear regression analyses were conducted to explore the association between academic performance and CRF, adjusted for SES, skinfold thickness or BMI-percentile. Among girls CRF was associated with higher academic achievement in math (β = 0.146;p = .003) and Portuguese (β = 0.129;p = .004) in crude and adjusted analyses. No significant association was found among boys. BMI was not associated with overall academic performance. There was a weak negative association between skinfold thickness and performance in mathematics in boys (β =- 0.030;p = .04), but not in girls. The results highlight the importance of maintaining high fitness levels in girls throughout adolescence a period commonly associated with reductions in physical activity levels and CRF.

  17. Bioactive leptin is stronger related to parameters of fat mass and distribution than conventionally measured leptin: Findings from a longitudinal study in obese children participating in a lifestyle intervention.

    Science.gov (United States)

    Niklowitz, Petra; Rothermel, Juliane; Lass, Nina; Barth, Andre; Reinehr, Thomas

    2018-05-01

    This study analyzed the relationships between bioactive leptin, conventionally measured leptin, and parameters of fat mass and distribution in obese children before and after weight reduction. We determined bioactive leptin (bioLep), conventional measured leptin (conLep), weight, height, body fat based on skinfold measurements and bioimpedance analyses, waist circumference (wc), and pubertal stage in 88 obese children participating in a lifestyle intervention at baseline and one year later. We identified no child with homozygous or heterozygous status for bioinactive leptin mutations. The baseline associations between bioLep and BMI (r = 0.53), BMI-SDS (r = 0.48), body fat (bioimpedance: r = 0.61, skinfold thickness: r = 0.49), wc (r = 0.42), and waist to height ratio (whr) (r = 0.39) were stronger than the associations between conLep and BMI (r = 0.50), BMI-SDS (r = 0.44), body fat (bioimpedance: r = 0.57, skinfold thickness: r = 0.41), wc (r = 0.41), and whr (r = 0.37). The changes of bioLep were stronger related to changes of BMI-SDS (r = 0.54), body fat (bioimpedance r = 0.59, skinfold thickness: r = 0.37), wc (r = 0.22), and whr (r = 0.21) than the associations between changes of conLep and changes of BMI-SDS (r = 0.48), body fat (bioimpedance: r = 0.56, skinfold thickness: r = 0.43), wc (r = 0.20), and whr (r = 0.20). The same findings were observed in multiple linear regression analyses adjusted to multiple confounders. In contrast to changes of conLep (r = 0.22), the changes of bioLep during intervention were not related to weight regain after the end of intervention. BioLep concentrations did not differ between prepubertal girls and boys, but were higher in pubertal girls compared to pubertal boys (p = 0.031). Bioactive leptin was stronger related to fat mass and distribution compared to conventionally measured leptin. Copyright © 2018 Elsevier B.V. All rights

  18. A new in vivo model using a dorsal skinfold chamber to investigate microcirculation and angiogenesis in diabetic wounds

    Directory of Open Access Journals (Sweden)

    Langer, Stefan

    2016-02-01

    Full Text Available Introduction: Diabetes mellitus describes a dysregulation of glucose metabolism due to improper insulin secretion, reduced insulin efficacy or both. It is a well-known fact that diabetic patients are likely to suffer from impaired wound healing, as diabetes strongly affects tissue angiogenesis. Until now, no satisfying in vivo murine model has been established to analyze the dynamics of angiogenesis during diabetic wound healing. To help understand the pathophysiology of diabetes and its effect on angiogenesis, a novel in vivo murine model was established using the skinfold chamber in mice.Materials and Methods: Mutant diabetic mice (db; wildtype mice ( and laboratory BALB/c mice were examined. They were kept in single cages with access to laboratory chow with an 12/12 hour day/night circle. Lesions of the panniculus muscle (Ø 2 mm were created in the center of the transparent window chamber and the subsequent muscular wound healing was then observed for a period of 22 days. Important analytic parameters included vessel diameter, red blood cell velocity, vascular permeability, and leakage of muscle capillaries and post capillary venules. The key parameters were functional capillary density (FCD and angiogenesis positive area (APA.Results: We established a model which allows high resolution in vivo imaging of functional angiogenesis in diabetic wounds. As expected, db mice showed impaired wound closure (day 22 compared to wounds of BALB/c or WT mice (day 15. FCD was lower in diabetic mice compared to WT and BALB/c during the entire observation period. The dynamics of angiogenesis also decreased in db mice, as reflected by the lowest APA levels. Significant variations in the skin buildup were observed, with the greatest skin depth in db mice. Furthermore, in db mice, the dermis:subcutaneous ratio was highly shifted towards the subcutaneous layers as opposed to WT or BALB/c mice.Conclusion: Using this new in vivo model of the skinfold chamber, it

  19. Body fat and blood pressure: comparison of blood pressure measurements in Chinese children with different body fat levels.

    Science.gov (United States)

    Ma, Jun; Wang, Zhiqiang; Dong, Bin; Song, Yi; Hu, Peijin; Zhang, Bing

    2012-11-14

    Children in China are experiencing a rapid increase in the prevalence of obesity, which is associated with hypertension. To compare the effect of body fat on blood pressure (BP) with that of the normal physical growth, we compared BP levels in Chinese children with different body fat levels. In the present population-based study, 13 972 children in the highest-skinfold-thickness-quartile group were individually matched to 13 972 children in the lowest-skinfold-thickness-quartile group by height and weight. Similarly, 5103 children in the highest-waist-circumference-quartile group were matched to the same number of children in the lowest-waist-circumference-quartile group. The high- and low-fat groups had similar height and weight but the high-fat group had significantly higher skinfold and waist circumference measurements. The differences in systolic BP (SBP) between the high- and low-skinfold-thickness groups were small: 0·01 (95 % CI -0·41, 0·44) mmHg in boys and 0·20 (95 % CI -0·15, 0·54) mmHg in girls. The differences in diastolic BP (DBP) were also small (0·39 and 0·38 mmHg for boys and girls, respectively) but were statistically significant. The differences in both SBP and DBP between the high- and low-waist-circumference groups were small but not statistically significant. For a given body size as measured by height and weight, relative body fat had little impact on BP levels in these children. Fat mass and lean mass may have a similar quantitative impact on BP in healthy-weight children.

  20. Association between Body Composition and Motor Performance in Preschool Children

    Directory of Open Access Journals (Sweden)

    Tanja H. Kakebeeke

    2017-09-01

    Full Text Available Objective: Being overweight makes physical movement more difficult. Our aim was to investigate the association between body composition and motor performance in preschool children. Methods: A total of 476 predominantly normal-weight preschool children (age 3.9 ± 0.7 years; m/f: 251/225; BMI 16.0 ± 1.4 kg/m2 participated in the Swiss Preschoolers' Health Study (SPLASHY. Body composition assessments included skinfold thickness, waist circumference (WC, and BMI. The Zurich Neuromotor Assessment (ZNA was used to assess gross and fine motor tasks. Results: After adjustment for age, sex, socioeconomic status, sociocultural characteristics, and physical activity (assessed with accelerometers, skinfold thickness and WC were both inversely correlated with jumping sideward (gross motor task β-coefficient -1.92, p = 0.027; and -3.34, p = 0.014, respectively, while BMI was positively correlated with running performance (gross motor task β-coefficient 9.12, p = 0.001. No significant associations were found between body composition measures and fine motor tasks. Conclusion: The inverse associations between skinfold thickness or WC and jumping sideward indicates that children with high fat mass may be less proficient in certain gross motor tasks. The positive association between BMI and running suggests that BMI might be an indicator of fat-free (i.e., muscle mass in predominately normal-weight preschool children.

  1. A comparison between two methods of measuring total fat in the Iranian soldiers

    Directory of Open Access Journals (Sweden)

    J. Rahmani

    2017-04-01

    Full Text Available Background: Constant checkup and control of body fat mass is an important parameter for the health and efficiency of individuals in any society. This parameter is especially crucial in army soldiers since physical fitness is a key role in reaching high physical performance, health, and survival in war. Objective: This study was designed to compare two methods of measuring fat, the method of circumference-based military equations (CBEs to estimate body fat mass compared to the method of skinfold thickness-based equation (SBE in Iranian soldiers. Methods: This cross-sectional study was conducted on 246 Iranian soldiers were recruited in Tehran (2016. Height, waist, and neck circumference were measured and the total body fat mass was calculated using CBEs. Then, the results of using Pierson’s correlation and Bland-Altman methods were compared with Jackson and Pollock’s skinfold thickness measurement. Findings: The total body fat mass of the soldiers using CBEs was 18.94±6.30% and using Jakson and Pollock’s skinfold thickness formula was 17.43±4.45%. The correlation between the two methods was r=0.984 and SEE was 1.1% (P<0.001. Conclusion: The more body fat makes the error waist circumference greater. The error is so much that don’t use this method to measure fat.

  2. The effect of individual antiretroviral drugs on body composition in HIV-infected persons initiating highly active antiretroviral therapy.

    Science.gov (United States)

    Shlay, Judith C; Sharma, Shweta; Peng, Grace; Gibert, Cynthia L; Grunfeld, Carl

    2009-07-01

    To examine the long-term effects of individual antiretroviral drugs on body composition among 416 persons initiating antiretroviral therapy (ART). In a substudy of a clinical trial of persons initiating ART, changes in body composition attributable to individual ART were examined. ARTs assessed were as follows: indinavir, ritonavir, nelfinavir, efavirenz, nevirapine, stavudine (d4T), zidovudine (ZDV), lamivudine (3TC), didanosine, and abacavir. Skinfolds and circumferences were measured at baseline and every 4 months. Mid arm, mid thigh, and waist subcutaneous tissue areas and nonsubcutaneous tissue areas were calculated. Rates of change per year of exposure to each individual ART drug were determined using multivariate longitudinal regression. d4T and ZDV use was associated with losses in subcutaneous tissue area and skinfold thickness. 3TC use was associated with gains in all subcutaneous tissue areas and skinfold thickness, whereas abacavir use was associated with an increase in waist subcutaneous tissue area. Indinavir was associated with gains in waist subcutaneous tissue area, whereas indinavir, efavirenz, and nevirapine were associated with increases in upper back skinfolds. d4T use was also associated with increases in all nonsubcutaneous tissue areas; 3TC use was associated with the greatest increase in waist nonsubcutaneous tissue area. In this prospective nonrandomized evaluation, the nucleoside reverse transcriptase inhibitors d4T and ZDV were associated with decreases in subcutaneous tissue areas, whereas 3TC use was associated with increased subcutaneous tissue areas and waist nonsubcutaneous tissue area.

  3. Estimating body weight and body composition of chickens by using noninvasive measurements.

    Science.gov (United States)

    Latshaw, J D; Bishop, B L

    2001-07-01

    The major objective of this research was to develop equations to estimate BW and body composition using measurements taken with inexpensive instruments. We used five groups of chickens that were created with different genetic stocks and feeding programs. Four of the five groups were from broiler genetic stock, and one was from sex-linked heavy layers. The goal was to sample six males from each group when the group weight was 1.20, 1.75, and 2.30 kg. Each male was weighed and measured for back length, pelvis width, circumference, breast width, keel length, and abdominal skinfold thickness. A cloth tape measure, calipers, and skinfold calipers were used for measurement. Chickens were scanned for total body electrical conductivity (TOBEC) before being euthanized and frozen. Six females were selected at weights similar to those for males and were measured in the same way. Each whole chicken was ground, and a portion of ground material of each was used to measure water, fat, ash, and energy content. Multiple linear regression was used to estimate BW from body measurements. The best single measurement was pelvis width, with an R2 = 0.67. Inclusion of three body measurements in an equation resulted in R2 = 0.78 and the following equation: BW (g) = -930.0 + 68.5 (breast, cm) + 48.5 (circumference, cm) + 62.8 (pelvis, cm). The best single measurement to estimate body fat was abdominal skinfold thickness, expressed as a natural logarithm. Inclusion of weight and skinfold thickness resulted in R2 = 0.63 for body fat according to the following equation: fat (%) = 24.83 + 6.75 (skinfold, ln cm) - 3.87 (wt, kg). Inclusion of the result of TOBEC and the effect of sex improved the R2 to 0.78 for body fat. Regression analysis was used to develop additional equations, based on fat, to estimate water and energy contents of the body. The body water content (%) = 72.1 - 0.60 (body fat, %), and body energy (kcal/g) = 1.097 + 0.080 (body fat, %). The results of the present study

  4. The Appropriateness of the Length of Insulin Needles Based on Determination of Skin and Subcutaneous Fat Thickness in the Abdomen and Upper Arm in Patients with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Kang Hee Sim

    2014-04-01

    Full Text Available BackgroundLonger needle and complicated insulin injection technique such as injecting at a 45-degree angle and making skinfolds may decrease patient compliance to insulin injection therapy. In this light, shorter insulin needles have been recently developed. However, it is necessary to ascertain that such shorter needles are appropriate for Korean patients with diabetes as well.MethodsFirst, the diverse demographic and diabetic features of 156 Korean adults with diabetes were collected by a questionnaire and a device unit of body fat measurement. The skin and subcutaneous fat thicknesses of each subject were measured by Ultrasound device with a 7- to 12-MHz probe. Data were analyzed using analysis of variance and multiple linear regression.ResultsThe mean skin thickness was 2.29±0.37 mm in the abdomen and 2.00±0.34 mm in the upper arms, and the mean subcutaneous fat thickness was to 10.15±6.54 mm in the abdomen and 5.50±2.68 mm in the upper arms. Our analysis showed that the factors affecting the skin thickness of the abdomen and upper arms were gender and body mass index (BMI, whereas the factors influencing the subcutaneous fat thickness in the abdomen were gender and BMI, and the factors influencing the subcutaneous fat thickness in the upper arms were gender, BMI, and age. Insulin fluids may not appear to be intradermally injected into the abdomen and upper arms at any needle lengths. The risk of intramuscular injection is likely to increase with longer insulin needles and lower BMI.ConclusionIt is recommended to fully inform the patients about the lengths of needles for insulin injections. As for the recommended needle length, the findings of this study indicate that needles as short as 4 mm are sufficient to deliver insulin for Korean patients with diabetes.

  5. [PHYSICAL ACTIVITY LEVELS, PHYSICAL FITNESS AND SCREE TIME AMONG CHILDREN AND ADOLESCENTS FROM BOGOTÁ, COLOMBIA].

    Science.gov (United States)

    Prieto-Benavides, Daniel Humberto; Correa-Bautista, Jorge Enrique; Ramírez-Vélez, Robinson

    2015-11-01

    to investigate the association between objective measures of physical activity levels, physical fitness and screen time in Colombia children and adolescents from Bogota, Colombia. a sample of 149 healthy Colombian youth, children and adolescents (9-17.9 years old) participated in the study. Physical activity level was assessed over 7 days using an accelerometer. Weight, height, waist circumference, hip waist, subscapular/ triceps skinfold thicknesses and self-reported screen time (television/internet and videogame-viewing time) were measured. Aerobic capacity, handgrip strength, standing broad jump, vertical jump, speed/agility and flexibility were used as indicators of physical fitness. in girls with a high level of physical activity had favorable aerobic capacity (r = 0.366) and inverse relationship with subscapular/triceps skinfold thicknesses (r = -0.257) and (r = -0,237) p < 0.05, respectively. In boys, vigorous physical activity were associated with higher values of flexibility (r = 0.277) and aerobic capacity (r = 0.347), p < 0.05. Finally, the participants who watched 2 h or less of television per day showed 1.81 times (95%CI 1.401 to 2.672) that met physical activity guidelines. the healthy Colombian youth who reported moderate to vigorous objective measures of physical activity levels, presented higher levels in physical fitness especially in aerobic capacity and flexibility and lower values in subscapular/triceps skinfold thicknesses. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  6. Effect of heat stress on six beef breeds in the Zastron district: the ...

    African Journals Online (AJOL)

    LA Foster

    and fat (7) and was determined on three occasions from January to March of 2008. Skin-fold thickness .... Respiration rate was measured on eleven events. The Rr rate .... Applied Genetics Publishing Inc. Cody, Wyoming, USA. Dowling, D.F. ...

  7. Body composition and energy metabolism in elderly people

    NARCIS (Netherlands)

    Visser, M.

    1995-01-01

    This thesis describes several studies related to the three components of energy balance in elderly people: body composition, energy expenditure, and energy intake.

    Body composition. The applicability of the body mass index, skinfold thickness method, and

  8. Full reflector thickness and isolation thickness on neutron transport

    International Nuclear Information System (INIS)

    Sakai, Tomohiro; Naito, Yoshitaka; Komuro, Yuichi.

    1988-08-01

    A method to determine ''full reflector thickness'' and ''isolation thickness'', which is utilized for criticality safety evaluation on nuclear fuel facilities, was proposed in this paper. Firstly, a calculation was tryed to obtain the two kinds of thicknesses from the result of criticality calculations for a specific case. Then, two simple equations which calculates the two kinds of thicknesses were made from the relation between reflector (or isolator) thickness and k eff , and one-group diffusion theory. Finally, we proposed a new method to determine the thicknesses. From the method we proposed, ''full reflector thickness'' and ''isolation thickness'' can be obtain using the equations and migration length of the reflector (or isolator) and infinite and effective multiplication factor of the fuel. (author)

  9. Anthropometry profiles of elite rugby players: quantifying changes in lean mass.

    Science.gov (United States)

    Duthie, G M; Pyne, D B; Hopkins, W G; Livingstone, S; Hooper, S L

    2006-03-01

    To demonstrate the utility of a practical measure of lean mass for monitoring changes in the body composition of athletes. Between 1999 and 2003 body mass and sum of seven skinfolds were recorded for 40 forwards and 32 backs from one Super 12 rugby union franchise. Players were assessed on 13 (7) occasions (mean (SD)) over 1.9 (1.3) years. Mixed modelling of log transformed variables provided a lean mass index (LMI) of the form mass/skinfolds(x), for monitoring changes in mass controlled for changes in skinfold thickness. Mean effects of phase of season and time in programme were modelled as percentage changes. Effects were standardised for interpretation of magnitudes. The exponent x was 0.13 for forwards and 0.14 for backs (90% confidence limits +/-0.03). The forwards had a small decrease in skinfolds (5.3%, 90% confidence limits +/-2.2%) between preseason and competition phases, and a small increase (7.8%, 90% confidence limits +/-3.1%) during the club season. A small decrease in LMI (approximately 1.5%) occurred after one year in the programme for forwards and backs, whereas increases in skinfolds for forwards became substantial (4.3%, 90% confidence limits +/-2.2%) after three years. Individual variation in body composition was small within a season (within subject SD: body mass, 1.6%; skinfolds, 6.8%; LMI, 1.1%) and somewhat greater for body mass (2.1%) and LMI (1.7%) between seasons. Despite a lack of substantial mean changes, there was substantial individual variation in lean mass within and between seasons. An index of lean mass based on body mass and skinfolds is a potentially useful tool for assessing body composition of athletes.

  10. Socio-cultural determinants of adiposity and physical activity in preschool children: a cross-sectional study.

    Science.gov (United States)

    Bürgi, Flavia; Meyer, Ursina; Niederer, Iris; Ebenegger, Vincent; Marques-Vidal, Pedro; Granacher, Urs; Kriemler, Susi; Puder, Jardena J

    2010-11-26

    Both individual socio-cultural determinants such as selected parental characteristics (migrant background, low educational level and workload) as well as the regional environment are related to childhood overweight and physical activity (PA). The purpose of the study was to compare the impact of distinct socio-cultural determinants such as the regional environment and selected parental characteristics on adiposity, PA and motor skills in preschool children. Forty preschools (N = 542 children) of two culturally different urban regions (German and French speaking part of Switzerland) participated in the study (Ballabeina Study). Outcome measures included adiposity (BMI and skinfold thickness), objectively measured sedentary activities and PA (accelerometers) and agility performance (obstacle course). Parental characteristics (migrant status, educational level and workload) were assessed by questionnaire. Children from the French speaking areas had higher adiposity, lower levels of total and of more intense PA, were more sedentary and less agile than children from the German speaking regions (percent differences for all outcome parameters except for BMI ≥10%; all p ≤ 0.04). Differences in skinfold thickness, sedentary activities and agility, but not in PA, were also found between children of Swiss and migrant parents, though they were ≤8% (p ≤ 0.02). While paternal workload had no effect, maternal workload and parental education resulted in differences in some PA measures and/or agility performance (percent differences in both: ≤9%, p ≤ 0.008), but not in adiposity or sedentary activities (p = NS). Regional differences in skinfold thickness, PA, sedentary activities and agility performance persisted after adjustment for parental socio-cultural characteristics, parental BMI and, where applicable, children's skinfolds (all p ≤ 0.01). The regional environment, especially the broader social environment, plays a prominent role in determining adiposity, PA and

  11. Socio-cultural determinants of adiposity and physical activity in preschool children: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Kriemler Susi

    2010-11-01

    Full Text Available Abstract Background Both individual socio-cultural determinants such as selected parental characteristics (migrant background, low educational level and workload as well as the regional environment are related to childhood overweight and physical activity (PA. The purpose of the study was to compare the impact of distinct socio-cultural determinants such as the regional environment and selected parental characteristics on adiposity, PA and motor skills in preschool children. Methods Forty preschools (N = 542 children of two culturally different urban regions (German and French speaking part of Switzerland participated in the study (Ballabeina Study. Outcome measures included adiposity (BMI and skinfold thickness, objectively measured sedentary activities and PA (accelerometers and agility performance (obstacle course. Parental characteristics (migrant status, educational level and workload were assessed by questionnaire. Results Children from the French speaking areas had higher adiposity, lower levels of total and of more intense PA, were more sedentary and less agile than children from the German speaking regions (percent differences for all outcome parameters except for BMI ≥10%; all p ≤ 0.04. Differences in skinfold thickness, sedentary activities and agility, but not in PA, were also found between children of Swiss and migrant parents, though they were ≤8% (p ≤ 0.02. While paternal workload had no effect, maternal workload and parental education resulted in differences in some PA measures and/or agility performance (percent differences in both: ≤9%, p ≤ 0.008, but not in adiposity or sedentary activities (p = NS. Regional differences in skinfold thickness, PA, sedentary activities and agility performance persisted after adjustment for parental socio-cultural characteristics, parental BMI and, where applicable, children's skinfolds (all p ≤ 0.01. Conclusions The regional environment, especially the broader social environment

  12. Single and Multiple Indicators of Physical Attractiveness and Psychosocial Behaviors among Young Adolescents.

    Science.gov (United States)

    Perkins, Daniel F.; Lerner, Richard M.

    1995-01-01

    Examined relations among several indicators of physical attractiveness (PA): height, weight, and triceps skinfold thickness. Appraised whether multiple PA indicators accounted for more variation in measures of psychosocial functioning than did single PA indexes. Facial attractiveness was the most frequent statistically significant predictor of…

  13. Novel equations to predict body fat percentage of Brazilian professional soccer players: A case study

    Directory of Open Access Journals (Sweden)

    Luiz Fernando Novack

    2014-12-01

    Full Text Available This study analyzed classical and developed novel mathematical models to predict body fat percentage (%BF in professional soccer players from the South Brazilian region using skinfold thicknesses measurement. Skinfolds of thirty one male professional soccer players (age of 21.48 ± 3.38 years, body mass of 79.05 ± 9.48 kg and height of 181.97 ± 8.11 cm were introduced into eight mathematical models from the literature for the prediction of %BF; these results were then compared to Dual-energy X-ray Absorptiometry (DXA. The classical equations were able to account from 65% to 79% of the variation of %BF in DXA. Statistical differences between most of the classical equations (seven of the eight classic equations and DXA were found, rendering their widespread use in this population useless. We developed three new equations for prediction of %BF with skinfolds from: axils, abdomen, thighs and calves. Theses equations accounted for 86.5% of the variation in %BF obtained with DXA.

  14. A randomized controlled intervention with fish oil versus sunflower oil from 9 to 18 months of age

    DEFF Research Database (Denmark)

    Andersen, Anders D; Michaelsen, Kim F; Hellgren, Lars

    2011-01-01

    intake affects adipose tissue growth, we randomly allocated 154 healthy infants to daily supplementation with FO or sunflower oil (SO) from 9 to 18 mo of age and measured z-score changes in various anthropometric assessments of body size and skinfold thicknesses and plasma adipokine concentrations. Among...

  15. Exclusive breastfeedingand postnatal changes in maternal ...

    African Journals Online (AJOL)

    To evaluate the impact of exclusive breastfeeding (EBFing) practice on maternal anthropometry during the first 6months of birth. Measurement of weight, height, triceps skin-fold thickness (TST), and mid-arm circumference (MAC) was carried out in a matched cohort of women practicing EBFing and those using other ...

  16. Personal best marathon time and longest training run, not anthropometry, predict performance in recreational 24-hour ultrarunners.

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Lepers, Romuald

    2011-08-01

    In recent studies, a relationship between both low body fat and low thicknesses of selected skinfolds has been demonstrated for running performance of distances from 100 m to the marathon but not in ultramarathon. We investigated the association of anthropometric and training characteristics with race performance in 63 male recreational ultrarunners in a 24-hour run using bi and multivariate analysis. The athletes achieved an average distance of 146.1 (43.1) km. In the bivariate analysis, body mass (r = -0.25), the sum of 9 skinfolds (r = -0.32), the sum of upper body skinfolds (r = -0.34), body fat percentage (r = -0.32), weekly kilometers ran (r = 0.31), longest training session before the 24-hour run (r = 0.56), and personal best marathon time (r = -0.58) were related to race performance. Stepwise multiple regression showed that both the longest training session before the 24-hour run (p = 0.0013) and the personal best marathon time (p = 0.0015) had the best correlation with race performance. Performance in these 24-hour runners may be predicted (r2 = 0.46) by the following equation: Performance in a 24-hour run, km) = 234.7 + 0.481 (longest training session before the 24-hour run, km) - 0.594 (personal best marathon time, minutes). For practical applications, training variables such as volume and intensity were associated with performance but not anthropometric variables. To achieve maximum kilometers in a 24-hour run, recreational ultrarunners should have a personal best marathon time of ∼3 hours 20 minutes and complete a long training run of ∼60 km before the race, whereas anthropometric characteristics such as low body fat or low skinfold thicknesses showed no association with performance.

  17. Lead Thickness Measurements

    International Nuclear Information System (INIS)

    Rucinski, R.

    1998-01-01

    The preshower lead thickness applied to the outside of D-Zero's superconducting solenoid vacuum shell was measured at the time of application. This engineering documents those thickness measurements. The lead was ordered in sheets 0.09375-inch and 0.0625-inch thick. The tolerance on thickness was specified to be +/- 0.003-inch. The sheets all were within that thickness tolerance. The nomenclature for each sheet was designated 1T, 1B, 2T, 2B where the numeral designates it's location in the wrap and 'T' or 'B' is short for 'top' or 'bottom' half of the solenoid. Micrometer measurements were taken at six locations around the perimeter of each sheet. The width,length, and weight of each piece was then measured. Using an assumed pure lead density of 0.40974 lb/in 3 , an average sheet thickness was calculated and compared to the perimeter thickness measurements. In every case, the calculated average thickness was a few mils thinner than the perimeter measurements. The ratio was constant, 0.98. This discrepancy is likely due to the assumed pure lead density. It is not felt that the perimeter is thicker than the center regions. The data suggests that the physical thickness of the sheets is uniform to +/- 0.0015-inch.

  18. Skin color and tissue thickness effects on transmittance, reflectance, and skin temperature when using 635 and 808 nm lasers in low intensity therapeutics.

    Science.gov (United States)

    Souza-Barros, Leanna; Dhaidan, Ghaith; Maunula, Mikko; Solomon, Vaeda; Gabison, Sharon; Lilge, Lothar; Nussbaum, Ethne L

    2018-04-01

    To examine the role of skin color and tissue thickness on transmittance, reflectance, and skin heating using red and infrared laser light. Forty volunteers were measured for skin color and skin-fold thickness at a standardized site near the elbow. Transmittance, reflectance and skin temperature were recorded for energy doses of 2, 6, 9, and 12 Joules using 635 nm (36 mW) and 808 nm (40 mW) wavelength laser diodes with irradiances within American National Standards Institute safety guidelines (4.88 mm diameter, 0.192 W/cm 2 and 4.88 mm diameter, 0.214 W/cm 2 , respectively). The key factors affecting reflectance to an important degree were skin color and wavelength. However, the skin color effects were different for the two wavelengths: reflectance decreased for darker skin with a greater decrease for red light than near infrared light. Transmittance was greater using 808 nm compared with 635 nm. However, the effect was partly lost when the skin was dark rather than light, and was increasingly lost as tissue thickness increased. Dose had an increasing effect on temperature (0.7-1.6°C across the 6, 9, and 12 J doses); any effects of wavelength, skin color, and tissue thickness were insignificant compared to dose effects. Subjects themselves were not aware of the increased skin temperature. Transmittance and reflectance changes as a function of energy were very small and likely of no clinical significance. Absorption did not change with higher energy doses and increasing temperature. Skin color and skin thickness affect transmittance and reflectance of laser light and must be accounted for when selecting energy dose to ensure therapeutic effectiveness at the target tissue. Skin heating appears not to be a concern when using 635 and 808 nm lasers at energy doses of up to 12 J and irradiance within American National Standards Institute standards. Photobiomodulation therapy should never exceed the American National Standards Institute

  19. The nutritional status of patients with tuberculosis in comparison with ...

    African Journals Online (AJOL)

    Mid-upper-arm circumference (MUAC) was measured to the nearest 1 mm and skinfold thickness measurements to the nearest 0.2 mm. The 24-hour dietary recall method was used to obtain dietary information and analysed in the nutrition database of the Medical Research Council in order to translate foods into nutrients.

  20. Mathematical model for body fat percentage of children with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Eduardo Borba Neves

    Full Text Available Abstract Introduction The aim of this study was to develop a specific mathematical model to estimate the body fat percentage (BF% of children with cerebral palsy, based on a Brazilian population of patients with this condition. Method This is a descriptive cross-sectional study. The study included 63 Caucasian children with cerebral palsy, both males and females, aged between three and ten-years-old. Participants were assessed for functional motor impairment using the Gross Motor Function Classification System (GMFCS, dual energy x-ray absorptiometry (DXA and skinfold thickness. Total body mass (TBM and skinfolds thickness from: triceps (Tr, biceps (Bi, Suprailiac (Si, medium thigh (Th, abdominal (Ab, medial calf (Ca and subscapular (Se were collected. Fat mass (FM was estimated by dual energy x-ray absorptiometry (gold standard. Results The model was built from multivariate linear regression; FM was set as a dependent variable and other anthropometric variables, age and sex, were set as independent variables. The final model was established as F%=((0.433xTBM + 0.063xTh + 0.167xSi - 6.768 ÷ TBM × 100, the R2 value was 0.950, R2adjusted=0.948 and the standard error of estimate was 1.039 kg. Conclusion This method was shown to be valid to estimate body fat percentage of children with cerebral palsy. Also, the measurement of skinfolds on both sides of the body showed good results in this modelling.

  1. Choroidal thickness in Malaysian eyes with full-thickness macular holes

    Directory of Open Access Journals (Sweden)

    Chew Y Tan

    2018-02-01

    Full Text Available AIM: To compare choroidal thickness at the macula in eyes with unilateral idiopathic full-thickness macular holes(FTMHwith that of unaffected fellow eyes, and eyes of normal control patients.METHODS: Cross-sectional study. Thirty patients with unilateral idiopathic FTMH and thirty age, sex, and race-matched controls were recruited. Axial lengths were measured using laser interferometry. Enhanced depth imaging optical coherence tomography images were obtained using Heidelberg spectral-domain optical coherence tomography. Choroidal thickness was measured at the fovea, and at 1 mm and 2 mm nasally, temporally, superiorly and inferiorly from the center of the fovea. Statistical analysis was performed using independent and paired t-tests, chi-square tests, and Pearson correlation tests(PRESULTS: The mean subfoveal choroidal thickness was 201.0±44.0 μm in the FTMH group, 225.3±51.4 μm in the fellow eye group and 262.3±70.3 μm in the control group. The choroid was thinner in FTMH eyes at all locations when compared to control eyes(PPP>0.05. Choroidal thickness was generally highest subfoveally and lowest nasally. Subfoveal choroidal thickness was negatively correlated with age(r=-0.278, P=0.032, and axial length(r=-0.328, P=0.011.CONCLUSION: Choroidal thickness is lower in both eyes of patients with unilateral FTMH compared to healthy control eyes.

  2. Adipose tissue content and distribution in children and adolescents with bronchial asthma.

    Science.gov (United States)

    Umławska, Wioleta

    2015-02-01

    The excess of adipose tissue and the pattern of adipose tissue distribution in the body seem to play an important role in the complicated dependencies between obesity and risk of developing asthma. The aim of the present study was to determine nutritional status in children and adolescents with bronchial asthma with special emphasis on adipose tissue distribution evaluated on the basis of skin-fold thicknesses, and to determine the relationships between patterns of adipose tissue distribution and the course of the disease. Anthropometric data on height, weight, circumferences and skin-fold thicknesses were extracted from the medical histories of 261 children diagnosed with asthma bronchitis. Values for children with asthma were compared to Polish national growth reference charts. Distribution of subcutaneous adipose tissue was evaluated using principal components analysis (PCA). Multivariate linear regression analyses tested the effect of three factors on subcutaneous adipose tissue distribution: type of asthma, the severity of the disease and the duration of the disease. Mean body height in the children examined in this study was lower than in their healthy peers. Mean BMI and skin-fold thicknesses were significantly higher and lean body mass was lower in the study group. Excess body fat was noted, especially in girls. Adipose tissue was preferentially deposited in the trunk in girls with severe asthma, as well as in those who had been suffering from asthma for a longer time. The type of asthma, atopic or non-atopic, had no observable effect on subcutaneous adipose tissue distribution in children examined. The data suggest that long-treated subjects and those with severe bronchial asthma accumulate more adipose tissue on the trunk. It is important to regularly monitor nutritional status in children with asthma, especially in those receiving high doses of systemic or inhaled glucocorticosteroids, and long-term treatment as well. Copyright © 2014 Elsevier Ltd. All

  3. Accuracy of Prediction Equations to Assess Percentage of Body Fat in Children and Adolescents with Down Syndrome Compared to Air Displacement Plethysmography

    Science.gov (United States)

    Gonzalez-Aguero, A.; Vicente-Rodriguez, G.; Ara, I.; Moreno, L. A.; Casajus, J. A.

    2011-01-01

    To determine the accuracy of the published percentage body fat (%BF) prediction equations (Durnin et al., Johnston et al., Brook and Slaughter et al.) from skinfold thickness compared to air displacement plethysmography (ADP) in children and adolescents with Down syndrome (DS). Twenty-eight children and adolescents with DS (10-20 years old; 12…

  4. Lean body mass in small for gestational age and appropriate for gestational age infants

    International Nuclear Information System (INIS)

    Petersen, S.; Gotfredsen, A.; Knudsen, F.U.

    1988-01-01

    Dual photon absorptiometry using 153 Gd in a whole-body scanner was used to measure lean body mass (LBM) in 51 newborn infants. LBM% decreased exponentially with increasing gestational age in both small for gestational age (SGA) and appropriate for gestational age (AGA) infants. In preterm SGA and AGA infants LBM was 104% and 103%, respectively, indicating that no fat was detectable. In term SGA infants LBM was 98%, which corresponded to 48 gm fat on average, and in term AGA infants LBM was 87%, which corresponded to 452 gm fat on average. The LBM%, ponderal index, and skinfold thickness were significantly different between AGA and SGA infants. Infants with clinical signs of intrauterine wastage had significantly higher LBM% than did infants without signs of weight loss. Our results on LBM% by dual photon absorptiometry agree with earlier dissection data; the clinically applicable methods of (1) height combined with weight (i.e., ponderal index), (2) skinfold thickness, and (3) scoring by clinical observations are useful for the estimation of lack of fat as an indicator of intrauterine growth retardation

  5. Growth during infancy and early childhood in relation to blood pressure and body fat measures at age 8-18 years of IVF children and spontaneously conceived controls born to subfertile parents.

    Science.gov (United States)

    Ceelen, Manon; van Weissenbruch, Mirjam M; Prein, Janneke; Smit, Judith J; Vermeiden, Jan P W; Spreeuwenberg, Marieke; van Leeuwen, Flora E; Delemarre-van de Waal, Henriette A

    2009-11-01

    Little is known about post-natal growth in IVF offspring and the effects of rates of early post-natal growth on blood pressure and body fat composition during childhood and adolescence. The follow-up study comprised 233 IVF children aged 8-18 years and 233 spontaneously conceived controls born to subfertile parents. Growth data from birth to 4 years of age, available for 392 children (n = 193 IVF, n = 199 control), were used to study early post-natal growth. Furthermore, early post-natal growth velocity (weight gain) was related to blood pressure and skinfold measurements at follow-up. We found significantly lower weight, height and BMI standard deviation scores (SDSs) at 3 months, and weight SDS at 6 months of age in IVF children compared with controls. Likewise, IVF children demonstrated a greater gain in weight SDS (P pressure in IVF children (P = 0.014 systolic, 0.04 diastolic) but not in controls. Growth during late infancy was not related to skinfold thickness in IVF children, unlike controls (P = 0.002 peripheral sum, 0.003 total sum). Growth during early childhood was related to skinfold thickness in both IVF and controls (P = 0.005 and 0.01 peripheral sum and P = 0.003 and 0.005 total sum, respectively). Late infancy growth velocity of IVF children was significantly higher compared with controls. Nevertheless, early childhood growth instead of infancy growth seemed to predict cardiovascular risk factors in IVF children. Further research is needed to confirm these findings and to follow-up growth and development of IVF children into adulthood.

  6. Static and dynamic through thickness lamina properties of thick laminates

    NARCIS (Netherlands)

    Lahuerta, F.; Nijssen, R.P.L.; Van der Meer, F.P.; Sluys, L.J.

    2015-01-01

    Thick laminates are increasingly present in large composites structures such as wind turbine blades. Different factors are suspected to be involved in the decreased static and dynamic performance of thick laminates. These include the effect of self-heating, the scaling effect, and the manufacturing

  7. Through thickness property variations in a thick plate AA7050 friction stir welded joint

    International Nuclear Information System (INIS)

    Canaday, Clinton T.; Moore, Matthew A.; Tang, Wei; Reynolds, A.P.

    2013-01-01

    In this study, moderately thick (32 mm) AA7050 plates were joined by friction stir welding (FSW). Various methods were used to characterize the welded joints, including nugget grain size measurements at different locations through the thickness, micro-hardness indentation through nugget, thermo-mechanically affected zone (TMAZ), and heat affected zone (HAZ) at different cross section heights, and residual stress measurement using the cut compliance method with full thickness and partial thickness specimens. All testing results are consistent with the presence of a strong gradient in peak temperature through the plate thickness during FSW.

  8. Effect of nutritional support in children with spastic quadriplegia.

    Science.gov (United States)

    Soylu, Ozlem Bekem; Unalp, Aycan; Uran, Nedret; Dizdarer, Gülsen; Ozgonul, Figen Oksel; Conku, Aliye; Ataman, Hamide; Ozturk, Aysel Aydogan

    2008-11-01

    Malnutrition is a common problem in patients with cerebral palsy. We evaluated the effect of nutritional support on clinical findings in children with spastic quadriplegia. Feeding history, numbers of lower respiratory tract infections, and gastrointestinal and neurologic findings were evaluated via questionnaire. Weight, height, head circumference, midarm circumference, and triceps skinfold thickness were measured. Height for age, weight for age, weight for height, body mass index, and weight and height z-scores were calculated. Clinical findings and anthropometric parameters were re-evaluated after nutritional support for 6 months. Forty-five patients were enrolled. No difference was evident between the first and the last height z-scores of 31 patients who completed the follow-up. Weight, height, weight z-scores, weight for age, weight for height, body mass index, midarm circumference, and triceps skinfold thickness exhibited improvement. Moreover, a significant decrease in number of infections was evident. Frequency of seizures and Gross Motor Function Classification System status did not change. Constipation decreased significantly. Nutritional therapy revealed improvements in some anthropometric findings and a decrease in number of infections. Although there was no difference regarding motor development or seizure frequency, further studies with a longer follow-up are required.

  9. Associations between adiposity indicators and elevated blood pressure among Chinese children and adolescents.

    Science.gov (United States)

    Dong, B; Wang, Z; Wang, H-J; Ma, J

    2015-04-01

    Adiposity is closely related to elevated blood pressure (BP); however, which adiposity indicator is the best predictor of elevated BP among children and adolescents is unclear. To clarify this, 99,366 participants aged 7-17 years from the Chinese National Survey on Students' Constitution and Health in 2010 were included in this study. The adiposity indicators, including weight, body mass index (BMI), waist circumference, waist-to-height ratio (WHtR), hip circumference, body adiposity index (BAI), waist-to-hip ratio (WHR) and skinfold thickness, were converted into z-scores before use. The associations between elevated BP and adiposity indicators z-scores were assessed by using logistic regression model and area under the receiver operating characteristic curve (AUC). In general, BAI, BMI and WHtR z-scores were superior for predicting elevated BP compared with weight, waist circumference, hip circumference, WHR and skinfold thickness z-scores. In both sexes, BMI z-score revealed slightly higher AUCs than other indicators. Our findings suggest that general adiposity indicators were equivalent, if not superior, to abdominal adiposity indicators to predict elevated BP. BMI could be a better predictor of elevated BP than other studied adiposity indicators in children.

  10. Non-contact radiation thickness gauge

    International Nuclear Information System (INIS)

    Tsujii, T.; Okino, T.

    1983-01-01

    A noncontact thickness gauge system for measuring the thickness of a material comprising a source of radiation, a detector for detecting the amount of radiation transmitted through the material which is a function of the absorptance and thickness of the material, a memory for storing the output signals of the detector and curve-defining parameters for a plurality of quadratic calibration curves which correspond to respective thickness ranges, and a processor for processing the signals and curve defining parameters to determine the thickness of the material. Measurements are made after precalibration to obtain calibration curves and these are stored in the memory, providing signals representative of a nominal thickness and an alloy compensation coefficient for the material. The calibration curve corresponding to a particular thickness range is selected and the curve compensated for drift; the material is inserted into the radiation path and the detector output signal processed with the compensated calibration curve to determine the thickness of the material. (author)

  11. Thickness filters for gradient based multi-material and thickness optimization of laminated composite structures

    DEFF Research Database (Denmark)

    Sørensen, Rene; Lund, Erik

    2015-01-01

    This paper presents a new gradient based method for performing discrete material and thickness optimization of laminated composite structures. The novelty in the new method lies in the application of so-called casting constraints, or thickness filters in this context, to control the thickness...... variation throughout the laminate. The filters replace the layerwise density variables with a single continuous through-the-thickness design variable. Consequently, the filters eliminate the need for having explicit constraints for preventing intermediate void through the thickness of the laminate....... Therefore, the filters reduce both the number of constraints and design variables in the optimization problem. Based upon a continuous approximation of a unit step function, the thickness filters are capable of projecting discrete 0/1 values to the underlying layerwise or ”physical” density variables which...

  12. Clinical and nutritional aspects of cystic fibrosis patients assisted by a home enteral nutrition program in Brazil

    OpenAIRE

    Haack, Adriana; Garbi Novaes, Maria Rita

    2013-01-01

    This study to assessed 47 cystic fibrosis (CF) patients assisted by a program of Home Enteral Nutrition. Anthropometric measurements included weight, height, triceps skinfold thickness, waist circunference and spirometry was also performed. Enzymes, nutritional and fat-soluble vitamin supplementations were recorded. There were no associations with enzymes and vitamin supplements between groups that did or did not have a nutritional deficit. Spirometry of patients without nutritional deficit, ...

  13. Comparison of 120- and 140-μm SMILE Cap Thickness Results in Eyes With Thick Corneas.

    Science.gov (United States)

    Liu, Manli; Zhou, Yugui; Wu, Xianghua; Ye, Tiantian; Liu, Quan

    2016-10-01

    To evaluate clinical outcomes after small incision lenticule extraction (SMILE) with different cap thicknesses in thick corneas. Forty patients with central corneal thickness of more than 560 μm were recruited in this prospective, randomized, masked, paired-eye study. Patients were randomized to receive SMILE with a 120-μm cap thickness in 1 eye and 140-μm cap thickness in the other. Uncorrected and corrected distance visual acuity (CDVA), contrast sensitivity (CS), higher-order aberrations (HOAs), and morphologic modifications of corneal architecture were measured during the 3-month follow-up period. Postoperative refractive outcomes, visual outcomes, CS, and the changes in HOAs were similar between both groups. The persistence of brightly reflective particles in the corneal interface layer was 1388.6 ± 219.5/mm in eyes with 120-μm cap thickness and 54.7 ± 8.6/mm in eyes with 140-μm cap thickness (P line at the interface layer almost disappeared in all eyes with 140-μm cap thickness, and it still persisted in 43% of the fellow eyes at 3 months postoperatively. The anterior surfaces of lenticules in the 140-μm cap thickness group exhibited more smoothness than in the 120-μm cap thickness group. There was a lower level corneal wound-healing response after SMILE with a 140-μm cap thickness than with a 120-μm cap thickness, although the thickness of cap creation did not affect visual outcomes by 3 months postoperatively.

  14. IL-6, TNF-α, IL-10, and nutritional status in pediatric patients with biliary atresia,

    Directory of Open Access Journals (Sweden)

    Maria Ines de Albuquerque Wilasco

    Full Text Available Abstract Objectives: The objective of the present study is to evaluate whether IL-6, TNF-α, IL-10 are associated with nutritional status in patients with cirrhosis secondary to biliary atresia and compare to healthy controls. Methods: The parameters used for nutritional assessment were the standard deviation scores of height-for-age and of triceps skinfold thickness-for-age. The severity of cirrhosis was evaluated using the Child–Pugh score and PELD/MELD. Serum cytokines were measured using Cytometric Bead Array flow cytometry. Results: IL-6, TNF-α, and IL-10 were significantly higher in the cirrhosis group when compared with the control group (2.4 vs. 0.24 (p < 0.001, 0.21 vs. 0.14 (p = 0.007, and 0.65 vs. 0.36 (p = 0.004, respectively. IL-6 and IL-10 were positively correlated with disease severity (0.450 [p = 0.001] and 0.410; [p = 0.002], respectively. TNF-α did not show a significant correlation with disease severity (0.100; p = 0.478. Regarding nutritional evaluation, IL-6 was negatively correlated with the standard deviation score of height-for-age (−0.493; p < 0.001 and of triceps skinfold thickness-for-age (−0.503; p < 0.001, respectively. IL-10 exhibited a negative correlation with the standard deviation score of height-for-age (−0.476; p < 0.001 and the standard deviation score of triceps skinfold thickness-for-age (−0.388; p = 0.004. TNF-α did not show any significance in both anthropometric parameters (−0.083 (p = 0.555 and −0.161 (p = 0.253. Conclusion: The authors suggest that, in patients with cirrhosis secondary to biliary atresia, IL-6 could be used as a possible supporting biomarker of deficient nutritional status and elevated IL-10 levels could be used as a possible early-stage supporting biomarker of deteriorating nutritional status.

  15. Comparison of anthropometric and training characteristics between recreational male marathoners and 24-hour ultramarathoners

    Directory of Open Access Journals (Sweden)

    Rüst CA

    2012-10-01

    Full Text Available Christoph Alexander Rüst,1 Beat Knechtle,1,2 Patrizia Knechtle,2 Thomas Rosemann11Institute of General Practice and for Health Services Research, University of Zurich, Zurich, 2Gesundheitszentrum St Gallen, St Gallen, SwitzerlandBackground: Of the anthropometry and training variables used to predict race performance in a 24-hour ultrarun, the personal best marathon time is the strongest predictor in recreational male 24-hour ultramarathoners. This finding raises the question of whether similarities exist between male recreational 24-hour ultramarathoners and male recreational marathoners.Methods: The association between age, anthropometric variables (ie, body mass, body height, body mass index, percent body fat, skeletal muscle mass, limb circumference, and skinfold thickness at the pectoral, mid axillary, triceps, subscapular, abdominal, suprailiac, front thigh, and medial calf sites, previous experience and training characteristics (ie, volume, speed, and personal best time, and race time for 79 male recreational 24-hour ultramarathoners and 126 male recreational marathoners was investigated using bivariate and multivariate analysis.Results: The 24-hour ultramarathoners were older (P < 0.05, had a lower circumference at both the upper arm (P < 0.05 and thigh (P < 0.01, and a lower skinfold thickness at the pectoral, axillary, and suprailiac sites (P < 0.05 compared with the marathoners. During training, the 24-hour ultramarathoners were running for more hours per week (P < 0.001 and completed more kilometers (P < 0.001, but were running slower (P < 0.01 compared with the marathoners. In the 24-hour ultramarathoners, neither anthropometric nor training variables were associated with kilometers completed in the race (P > 0.05. In the marathoners, percent body fat (P < 0.001 and running speed during training (P < 0.0001 were related to marathon race times.Conclusion: In summary, differences in anthropometric and training predictor variables do

  16. Thickness-Dependent Bioelectrochemical and Energy Applications of Thickness-Controlled Meso-Macroporous Antimony-Doped Tin Oxide

    Directory of Open Access Journals (Sweden)

    Daniel Mieritz

    2018-04-01

    Full Text Available Coatings of hierarchically meso-macroporous antimony-doped tin oxide (ATO enable interfacing adsorbed species, such as biomacromolecules, with an electronic circuit. The coating thickness is a limiting factor for the surface coverage of adsorbates, that are electrochemically addressable. To overcome this challenge, a carbon black-based templating method was developed by studying the composition of the template system, and finding the right conditions for self-standing templates, preventing the reaction mixture from flowing out of the mask. The thicknesses of as-fabricated coatings were measured using stylus profilometry to establish a relationship between the mask thickness and the coating thickness. Cyclic voltammetry was performed on coatings with adsorbed cytochrome c to check whether the entire coating thickness was electrochemically addressable. Further, bacterial photosynthetic reaction centers were incorporated into the coatings, and photocurrent with respect to coating thickness was studied. The template mixture required enough of both carbon black and polymer, roughly 7% carbon black and 6% poly(ethylene glycol. Coatings were fabricated with thicknesses approaching 30 µm, and thickness was shown to be controllable up to at least 15 µm. Under the experimental conditions, photocurrent was found to increase linearly with the coating thickness, up to around 12 µm, above which were diminished gains.

  17. Perfil antropométrico de mulheres adultas da área urbana e rural no município de Barcelos, AM Anthropometric profile of women from the urban and rural areas in Barcelos municipality. (Amazonas, Brazil

    Directory of Open Access Journals (Sweden)

    Dionísia Nagahama

    2003-01-01

    Full Text Available De um total de 203 mulheres adultas entrevistadas, foram avaliadas 175 (entre 16 a 73 anos, por meio de medidas antropométricas: peso, altura, prega cutânea tricipital (PCT, circunferência braquial (CB, circunferência muscular (CMB e Índice de Massa Corpórea (IMC. Das mulheres analisadas, 84,0% (n=147 residiam na zona urbana e 16,0% (n=28 na zona rural. Verificou-se que o peso médio das mulheres não nutrizes residentes na área urbana foi de 54,1 kg; altura de 149,0 cm e o IMC de 24,4 kg/m², enquanto que a PCT, CB e a CMB forneceram valores médios de 19,2 mm, 27,5 cm e 21,5 cm, respectivamente. Na área rural, as mulheres apresentaram um peso médio de 50,4 kg, altura de 148,6 cm, IMC de 23,0 kg/cm² e a PCT, CB e a CMB foram 13,8 mm, 26,4 cm e 22,1 cm, respectivamente. Houve diferença estatisticamente significativa apenas nos valores médios da PCT entre as mulheres procedentes da área urbana e rural (pFrom a total of 203 adult women interviewed, 175 subjects aged 16 to 73 years were evaluated for the anthropometrics variables: weight, height, triceps skinfold thickness, mid-upper arm circumference, arm muscle circumference and body mass index (BMI. Of these women, 84,0% (147 were living in the urban area and 16,0% (28 in the rural area. Observing the mean values for non-lactating women in the urban area were: weight 54,1 kg, height 149,0 cm, BMI 24,4 kg/m², triceps skinfold thickness 19,2 mm, arm circumference 27,5 cm, arm muscle circumference 21,5 cm. For women in the rural area the values were: weight 50,4 kg, height 148,6 cm, BMI 23,0 kg/cm², triceps skinfold thickness 13,8 mm, arm circumference 26,4 cm, arm muscle circumference 22,1 cm. There was a significant difference in the average triceps skinfold thickness values between women in the rural area and women in the urban area (p<0,05. In the urban area women a 6,5% prevalence of low weight was found, a 28,2% prevalence of overweight and a 11,3% prevalence of obesity. In the

  18. Central obesity and risk for type 2 diabetes in Maori, Pacific and European young men in New Zealand

    Energy Technology Data Exchange (ETDEWEB)

    Rush, E; Laulu, M S [Department of Applied Science, Auckland Institute of Technology, Auckland (New Zealand); Mitchelson, E [Department of Nursing, Unitec Institute of Technology, Auckland (New Zealand); Plank, L [Department of Surgery, School of Medicine, University of Auckland, Auckland (New Zealand)

    2002-07-01

    Thirty healthy male volunteers between the ages of 18 and 27 and of a wide range of fatness were recruited for this study. Equal numbers (10) self identified as belonging to each of the Maori Pacific and European ethnic groups. Originally it was intended that 90 men(30 in each group) should be measured but the cost and availability of the doubly-labelled water prevented this. Specific measurements undertaken included resting metabolic rate by indirect calorimetry, total energy expenditure over 14 days by the doubly-labelled water technique; total and regional body fat from dual-energy x-ray absorptiometry; anthropometry (body mass index, skinfold thicknesses and girths); fat and carbohydrate utilisation from respiratory quotients and from carbon-13 analysis of expired breath; and dietary intake of macronutrients. Glucose tolerance, insulin, thyroid hormone, leptin and blood lipid determinations were also performed. The groups did not differ significantly in BMI, height body mass or fat mass - but the European group had significantly lower subscapular to triceps skinfolds and fat free mass than the Maori and Pacific group. Resting metabolic rate adjusted for fat mass and fat free mass was not different among the groups. Carbon-13 in expired breath was positively correlated to the subscapular to triceps skinfold ratio and insulin. Reported intake of dietary fibre was negatively related to blood lipids and subscapular to triceps skinfold ratio. Central obesity showed strong associations with biochemical measures of Type 2 diabetes risk These findings emphasise the relationships between body composition and fat distribution with risk of diabetes independent of ethnicity. (author)

  19. Central obesity and risk for type 2 diabetes in Maori, Pacific and European young men in New Zealand

    International Nuclear Information System (INIS)

    Rush, E.; Laulu, M.S.; Mitchelson, E.; Plank, L.

    2002-01-01

    Thirty healthy male volunteers between the ages of 18 and 27 and of a wide range of fatness were recruited for this study. Equal numbers (10) self identified as belonging to each of the Maori Pacific and European ethnic groups. Originally it was intended that 90 men(30 in each group) should be measured but the cost and availability of the doubly-labelled water prevented this. Specific measurements undertaken included resting metabolic rate by indirect calorimetry, total energy expenditure over 14 days by the doubly-labelled water technique; total and regional body fat from dual-energy x-ray absorptiometry; anthropometry (body mass index, skinfold thicknesses and girths); fat and carbohydrate utilisation from respiratory quotients and from carbon-13 analysis of expired breath; and dietary intake of macronutrients. Glucose tolerance, insulin, thyroid hormone, leptin and blood lipid determinations were also performed. The groups did not differ significantly in BMI, height body mass or fat mass - but the European group had significantly lower subscapular to triceps skinfolds and fat free mass than the Maori and Pacific group. Resting metabolic rate adjusted for fat mass and fat free mass was not different among the groups. Carbon-13 in expired breath was positively correlated to the subscapular to triceps skinfold ratio and insulin. Reported intake of dietary fibre was negatively related to blood lipids and subscapular to triceps skinfold ratio. Central obesity showed strong associations with biochemical measures of Type 2 diabetes risk These findings emphasise the relationships between body composition and fat distribution with risk of diabetes independent of ethnicity. (author)

  20. Autonomous Sea-Ice Thickness Survey

    Science.gov (United States)

    2016-06-01

    the conductivity of an infinitely thick slab of sea ice. Ice thickness, Hice, is then obtained by subtracting the height of the ...Thickness Survey of Sea Ice Runway” ERDC/CRREL SR-16-4 ii Abstract We conducted an autonomous survey of sea -ice thickness using the Polar rover Yeti...efficiency relative to manual surveys routinely con- ducted to assess the safety of roads and runways constructed on the sea ice. Yeti executed the

  1. Thickness evaluation using a new relationship between film density and penetrated thickness in radiography

    International Nuclear Information System (INIS)

    Lee, Sung Sik; Kim, Young H.

    2005-01-01

    In order to improve the accuracies in the thickness evaluation using radiography, a new relationship between film density and penetrated thickness has been proposed, and experimental verification of the proposed relationship was carried out by using the X- and γ-ray radiographs of two carbon steel step wedges. A new parameter, the logarithmic gradient of film density, was defined in order to express the characteristics of the radiographic film for wider range of film density. A new relationship between the film density and the penetrated thickness were formulated using the logarithmic gradient of the film density. In experiment, the logarithmic gradient of the film density was independent on both the exposure and the film density and measured for the radiographic film used in the present work from the slope of the fitting lines for the same penetrated thickness. Experimental results verifies the accuracy of the proposed relationship between film density and the penetrated thickness for the range of film density from 1.0 to 3.5. The thickness can be more accurately determined by using the proposed relationship and the parameters determined by experiment. It is also found that the γ-ray having simple energy spectrum is more appropriate radiation source for the evaluation of the thickness from the film density of the radiograph

  2. Disentangling The Thick Concept Argument

    DEFF Research Database (Denmark)

    Blomberg, Olle

    2007-01-01

    Critics argue that non-cognitivism cannot adequately account for the existence and nature of some thick moral concepts. They use the existence of thick concepts as a lever in an argument against non-cognitivism, here called the Thick Concept Argument (TCA). While TCA is frequently invoked...

  3. Application of Industrial XRF Coating Thickness Analyzer for Phosphate Coating Thickness on Steel

    Directory of Open Access Journals (Sweden)

    Aleksandr Sokolov

    2018-03-01

    Full Text Available The results of industrial application of an online X-ray fluorescence coating thickness analyzer for measuring the thickness of phosphate coatings on moving steel strips are considered in the article. The target range of coating thickness to be measured is from tens to hundreds of mg/m2 in a measurement time of 10 s. The measurement accuracy observed during long-duration factory acceptance test was 10–15%. The coating thickness analyzer consists of two XRF gauges, mounted above and below the steel strip and capable of moving across the moving strip system for their suspension and relocation and electronic control unit. Fully automated software was developed to automatically and continuously (24/7 control both gauges, scanning both sides of the steel strip, and develop and test methods for measuring new coatings. It allows performing offline storage and retrieval of the measurement results, remotely controlling the analyzer components and measurement modes from a control room. The developed XRF coating thickness analyzer can also be used for real-time measurement of other types of coatings, both metallic and non-metallic.

  4. Cranial vault thickness in primates: Homo erectus does not have uniquely thick vault bones.

    Science.gov (United States)

    Copes, Lynn E; Kimbel, William H

    2016-01-01

    Extremely thick cranial vaults have been noted as a diagnostic characteristic of Homo erectus since the first fossil of the species was identified, but relatively little work has been done on elucidating its etiology or variation across fossils, living humans, or extant non-human primates. Cranial vault thickness (CVT) is not a monolithic trait, and the responsiveness of its layers to environmental stimuli is unknown. We obtained measurements of cranial vault thickness in fossil hominins from the literature and supplemented those data with additional measurements taken on African fossil specimens. Total CVT and the thickness of the cortical and diploë layers individually were compared to measures of CVT in extant species measured from more than 500 CT scans of human and non-human primates. Frontal and parietal CVT in fossil primates was compared to a regression of CVT on cranial capacity calculated for extant species. Even after controlling for cranial capacity, African and Asian H. erectus do not have uniquely high frontal or parietal thickness residuals, either among hominins or extant primates. Extant primates with residual CVT thickness similar to or exceeding H. erectus (depending on the sex and bone analyzed) include Nycticebus coucang, Perodicticus potto, Alouatta caraya, Lophocebus albigena, Galago alleni, Mandrillus sphinx, and Propithecus diadema. However, the especially thick vaults of extant non-human primates that overlap with H. erectus values are composed primarily of cortical bone, while H. erectus and other hominins have diploë-dominated vault bones. Thus, the combination of thick vaults comprised of a thickened diploë layer may be a reliable autapomorphy for members of the genus Homo. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Multi-frequency bioelectrical impedance analysis (BIA) compared to magnetic resonance imaging (MRI) for estimation of fat-free mass in colorectal cancer patients treated with chemotherapy

    DEFF Research Database (Denmark)

    Palle, Stine Skov; Tang Møllehave, Line; Kadkhoda, Zahra Taheri

    2016-01-01

    during the course of their treatments. Objective: To examine relationships between single cross-sectional thighs magnetic resonance imaging (MRI), skeletal muscle mass (SM) as reference and multi-frequency bioelectrical impedance analysis (BIA) fat free mass (FFM) in patients with colorectal cancer...... undergoing chemotherapy. Design: In an observational, prospective study we examine the relationships between single cross-sectional thighs MRI (T1-weighted (1.5 T) SM compared to FFM BIA (8-electrodes multi-frequency Tanita MC780MA)) and FFM skin-fold thickness (ST) (4-points (Harpenden, Skinfold Caliper......)) and SM equation for non-obese persons from Lee et al. 2000 (L2000) (based on age, height, weight, sex and race). FFM and SM (kg) were calculated based on either area (MRI) or weight. Results: 18 CRC patients (10 males and 8 females) with mean (SD) age 67 yr (6) were measured at baseline, and 13 were...

  6. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    Science.gov (United States)

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be

  7. Anthropometric, morphological and somatotype characteristics of athletes of the Brazilian Men’s volleyball team: an 11-year descriptive study

    Directory of Open Access Journals (Sweden)

    Edio Luiz Petroski

    2013-03-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2013v15n2p184 This study analyzed the anthropometric and morphological characteristics of the adult male players in the Brazilian volleyball team for 11 years. The sample comprised 92 athletes selected for the national team from 1995 to 2005. Anthropometric measures were collected and body composition and somatotype components were estimated. Oneway ANOVA and the Bonferroni test were used for descriptive statistical analysis, and the level of significance was set at p<0.05. Along the 11 years, there was a significant increase in the flexed arm perimeter, humerus diameter and lean mass. Skinfold thickness and percent body fat tended to decrease. Height increased and was greater than 1.97 m. The somatotype of the volleyball players in the Brazilian team changed along the years. Ectomorphic and mesomorphic somatotypes were the most frequent. In 11 years, the athletes selected for the Brazilian team had an increase in body mass and a decrease in skinfold thickness and percent body fat. The most frequent anthropometric classifications were mesomorph-ectomorph for five years, followed by mesomorphic-ectomorph for three years, which suggests that greater height and low body fat were taken into consideration when selecting athletes for the national team

  8. Comparison between recreational male Ironman triathletes and marathon runners.

    Science.gov (United States)

    Gianoli, Daniele; Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Rüst, Christoph Alexander; Rosemann, Thomas

    2012-08-01

    Recent investigations described a personal best marathon time as a predictor variable for an Ironman race time in recreational male Ironman triathletes. Similarities and differences in anthropometry and training were investigated between 83 recreational male Ironman triathletes and 81 recreational male marathoners. Ironman triathletes were significantly taller and had a higher body mass and a higher skin-fold thickness of the calf compared to the marathoners. Weekly training volume in hours was higher in Ironman triathletes. In the Ironman triathletes, percent body fat was related to overall race time and both the split time in cycling and running. The weekly swim kilometres were related to the split time in swimming, and the speed in cycling was related to the bike split time. For the marathoners, the calf skin-fold thickness and running speed during training were related to marathon race time. Although personal best marathon time was a predictor of Ironman race time in male triathletes, anthropometric and training characteristics of male marathoners were different from those of male Ironman triathletes, probably due to training of different muscle groups and metabolic endurance beyond marathon running, as the triathletes are also training for high-level performance in swimming and cycling. Future studies should compare Olympic distance triathletes and road cyclists with Ironman triathletes.

  9. Longitudinal Associations of Exposure to Perfluoroalkylated Substances in Childhood and Adolescence and Indicators of Adiposity and Glucose Metabolism 6 and 12 Years Later: The European Youth Heart Study.

    Science.gov (United States)

    Domazet, Sidsel L; Grøntved, Anders; Timmermann, Amalie G; Nielsen, Flemming; Jensen, Tina K

    2016-10-01

    To investigate the long-term association of exposure to perfluoroalkylated substances, including perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), during childhood (9 years) and adolescence (15 years) on indicators of adiposity and glucose metabolism in adolescence (15 years) and young adulthood (21 years). Secondarily, we aim to clarify the degree of tracking of exposure from childhood into young adulthood. Data derived from a large multicenter prospective cohort study, in which the same participants have been observed from childhood (N = 590), during adolescence (N = 444), and into young adulthood (N = 369). Stored plasma samples were analyzed for PFOS and PFOA. Indicators of adiposity comprising body height, body weight, sum of four skinfolds, and waist circumference, as well as indicators of glucose metabolism, comprising fasting blood glucose, triglyceride, and insulin levels, β-cell function, and insulin resistance, have been collected at all study waves. Multiple linear regression was applied in order to model earlier exposure on later outcome while controlling for baseline outcome levels, sex, age, and socioeconomic factors. Childhood exposure to PFOS was associated with indicators of adiposity at 15 years of age that are displayed in elevated BMI, skinfold thickness, and waist circumference, as well as increased skinfold thickness and waist circumference at 21 years of age. PFOA exposure in childhood was associated with decreased β-cell function at 15 years of age. We did not observe associations between exposure during adolescence and indicators of adiposity and glucose metabolism in young adulthood. This study found evidence for childhood exposure to PFOS and PFOA predicting adiposity at 15 and 21 years of age and impaired β-cell function at 15 years of age, respectively. © 2016 by the American Diabetes Association.

  10. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato and others

    1989-02-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K).

  11. Influence of slice thickness on the determination of left ventricular wall thickness and dimension by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato

    1989-01-01

    Wall thickness of the ventricular septum and left ventricle, and left ventricular cavity dimension were determined on magnetic resonance (MR) images with slices 5 mm and 10 mm in thickness. Subjects were 3 healthy volunteers and 7 patients with hypertension (4), hypertrophic cardiomyopathy (one) or valvular heart disease (2). In visualizing the cardiac structures such as left ventricular papillary muscle and right and left ventricles, 5 mm-thick images were better than 10 mm-thick images. Edges of ventricular septum and left ventricular wall were more clearly visualized on 5 mm-thick images than 10 mm-thick images. Two mm-thick MR images obtained from 2 patients yielded the most excellent visualization in end-systole, but failed to reveal cardiac structures in detail in end-diastole. Phantom studies revealed no significant differences in image quality of 10 mm and 5 mm in thickness in the axial view 80 degree to the long axis. In the axial view 45 degree to the long axis, 10 mm-thick images were inferior to 5 mm-thick images in detecting the edge of the septum and the left ventricular wall. These results indicate that the selection of slice thickness is one of the most important determinant factors in the measurement of left ventricular wall thickness and cavity dimension. (Namekawa, K)

  12. Corneal thickness: measurement and implications.

    Science.gov (United States)

    Ehlers, Niels; Hjortdal, Jesper

    2004-03-01

    The thickness of the cornea was reported in more than 100-year-old textbooks on physiological optics (Helmholtz, Gullstrand). Physiological interest was revived in the 1950s by David Maurice, and over the next 50 years, this 'simple' biological parameter has been studied extensively. Several techniques for its measurement have been described and physiological and clinical significance have been studied. In this review, the different methods and techniques of measurement are briefly presented (optical, ultrasound). While the corneal thickness of many animals are the same over a considerable part of the surface, in the human cornea anterior and posterior curvature are not concentric giving rise to a problem of definition. Based on this the precision and accuracy of determining the central corneal thickness are discussed. Changes in corneal thickness reflects changes in function of the boundary layers, in particular the endothelial barrier. The absolute value of thickness is of importance for the estimation of IOP but also in diagnosis of corneal and systemic disorders. Finally it is discussed to what extent the thickness is a biometric parameter of significance, e.g. in the progression of myopia or in the development of retinal detachment.

  13. Overweight and obesity in students of a dental college of Karachi: lifestyle influence and measurement by an appropriate anthropometric index.

    Science.gov (United States)

    Hingorjo, Mozaffer Rahim; Syed, Sadiqa; Qureshi, Masood Anwar

    2009-08-01

    To compare body mass index (BMI), waist circumference (WC), and body fat percentage (%BF), as index of overweight and obesity in young adults. We also intended to find an association between lifestyle behaviours and obesity. A cross-sectional study was conducted at Fatima Jinnah Dental College, Karachi, during 2007 to 2008, with 192 first year dental students, (18-21years) of high socioeconomic class. All were questioned regarding lifestyle behaviours. Overweight and obesity were estimated by measuring %BF, BMI, and WC. For %BF, skinfold thickness was measured using skinfold calipers. BMI > or = 23.0-24.9 kg/m2 was taken as overweight and > or = 25.0 kg/m2 as obese (Asians criteria proposed by Western Pacific Regional Office of World Health Organization). WC using Asian cutoff values for overweight and obesity were: males > or = 78 cm and > or = 90 cm; females > or = 72 cm and > or = 80 cm, respectively. Body fat percentage used to define overweight and obesity was: males 22.1-27.0 and > 27.1; females 27.1-32.0 and > 32.1, respectively. Pearson's correlation was done between the BMI, WC and %BF with statistical significance taken at P obese. Obesity was underpredicted by BMI when compared to skinfold calipers method. The obese were seen to skip breakfast more often [odds ratio (OR): 2.39], take frequent snacks (OR: 1.58), watch television more (OR: 1.58), and were physically less active than their non-obese counterparts. Body fat percentage using skinfold caliper is a reliable index of obesity. Lack of sleep and skipping of breakfast, are prominent promoters of obesity, in addition to other lifestyle behaviours.

  14. Predictor variables for half marathon race time in recreational female runners

    OpenAIRE

    Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Rosemann, Thomas; Lepers, Romuald

    2011-01-01

    INTRODUCTION: The relationship between skin-fold thickness and running performance has been investigated from 100 m to the marathon distance, except the half marathon distance. OBJECTIVE: To investigate whether anthropometry characteristics or training practices were related to race time in 42 recreational female half marathoners to determine the predictor variables of half-marathon race time and to inform future novice female half marathoners. METHODS: Observational field study at the ‘Half ...

  15. Three-dimensional primate molar enamel thickness.

    Science.gov (United States)

    Olejniczak, Anthony J; Tafforeau, Paul; Feeney, Robin N M; Martin, Lawrence B

    2008-02-01

    Molar enamel thickness has played an important role in the taxonomic, phylogenetic, and dietary assessments of fossil primate teeth for nearly 90 years. Despite the frequency with which enamel thickness is discussed in paleoanthropological discourse, methods used to attain information about enamel thickness are destructive and record information from only a single plane of section. Such semidestructive planar methods limit sample sizes and ignore dimensional data that may be culled from the entire length of a tooth. In light of recently developed techniques to investigate enamel thickness in 3D and the frequent use of enamel thickness in dietary and phylogenetic interpretations of living and fossil primates, the study presented here aims to produce and make available to other researchers a database of 3D enamel thickness measurements of primate molars (n=182 molars). The 3D enamel thickness measurements reported here generally agree with 2D studies. Hominoids show a broad range of relative enamel thicknesses, and cercopithecoids have relatively thicker enamel than ceboids, which in turn have relatively thicker enamel than strepsirrhine primates, on average. Past studies performed using 2D sections appear to have accurately diagnosed the 3D relative enamel thickness condition in great apes and humans: Gorilla has the relatively thinnest enamel, Pan has relatively thinner enamel than Pongo, and Homo has the relatively thickest enamel. Although the data set presented here has some taxonomic gaps, it may serve as a useful reference for researchers investigating enamel thickness in fossil taxa and studies of primate gnathic biology.

  16. Thickly Syndetical Sensitivity of Topological Dynamical System

    Directory of Open Access Journals (Sweden)

    Heng Liu

    2014-01-01

    Full Text Available Consider the surjective continuous map f:X→X, where X is a compact metric space. In this paper we give several stronger versions of sensitivity, such as thick sensitivity, syndetic sensitivity, thickly syndetic sensitivity, and strong sensitivity. We establish the following. (1 If (X,f is minimal and sensitive, then (X,f is syndetically sensitive. (2 Weak mixing implies thick sensitivity. (3 If (X,f is minimal and weakly mixing, then it is thickly syndetically sensitive. (4 If (X,f is a nonminimal M-system, then it is thickly syndetically sensitive. Devaney chaos implies thickly periodic sensitivity. (5 We give a syndetically sensitive system which is not thickly sensitive. (6 We give thickly syndetically sensitive examples but not cofinitely sensitive ones.

  17. Education and "Thick" Epistemology

    Science.gov (United States)

    Kotzee, Ben

    2011-01-01

    In this essay Ben Kotzee addresses the implications of Bernard Williams's distinction between "thick" and "thin" concepts in ethics for epistemology and for education. Kotzee holds that, as in the case of ethics, one may distinguish between "thick" and "thin" concepts of epistemology and, further, that this distinction points to the importance of…

  18. Relationship between macular ganglion cell complex thickness and macular outer retinal thickness: a spectral-domain optical coherence tomography study.

    Science.gov (United States)

    Kita, Yoshiyuki; Kita, Ritsuko; Takeyama, Asuka; Anraku, Ayako; Tomita, Goji; Goldberg, Ivan

    2013-01-01

    To assess the relationship between macular ganglion cell complex and macular outer retinal thicknesses. Case-control study. Forty-two normal eyes and 91 eyes with primary open-angle glaucoma were studied. Spectral-domain optical coherence tomography (RTVue-100) was used to measure the macular ganglion cell complex and macular outer retinal thickness. Ganglion cell complex to outer retinal thickness ratio was also calculated. The relationships between the ganglion cell complex and outer retinal thicknesses and between the ganglion cell complex to outer retinal thickness ratio and outer retinal thickness were evaluated. There was a positive correlation between ganglion cell complex and outer retinal thicknesses in the normal group and the glaucoma group (r = 0.53, P variation in the outer retinal thickness. Therefore, when determining the ganglion cell complex, it seems necessary to consider the outer retinal thickness as well. We propose the ratio as a suitable parameter to account for individual variations in outer retinal thickness. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  19. Use of buffy coat thick films in detecting malaria parasites in patients with negative conventional thick films.

    Science.gov (United States)

    Duangdee, Chatnapa; Tangpukdee, Noppadon; Krudsood, Srivicha; Wilairatana, Polrat

    2012-04-01

    To determine the frequency of malaria parasite detection from the buffy coat blood films by using capillary tube in falciparum malaria patients with negative conventional thick films. Thirty six uncomplicated falciparum malaria patients confirmed by conventional thick and thin films were included in the study. The patients were treated with artemisinin combination therapy at Hospital for Tropical Diseases, Bangkok, Thailand for 28 day. Fingerpricks for conventional blood films were conducted every 6 hours until negative parasitemia, then daily fingerpricks for parasite checks were conducted until the patients were discharged from hospital. Blood samples were also concurrently collected in 3 heparinized capillary tubes at the same time of fingerpricks for conventional blood films when the prior parasitemia was negative on thin films and parasitemia was lower than 50 parasites/200 white blood cells by thick film. The first negative conventional thick films were compared with buffy coat thick films for parasite identification. Out of 36 patients with thick films showing negative for asexual forms of parasites, buffy coat films could detect remaining 10 patients (27.8%) with asexual forms of Plasmodium falciparum. The study shows that buffy coat thick films are useful and can detect malarial parasites in 27.8% of patients whose conventional thick films show negative parasitemia.

  20. Effect of the Ti-Nanolayer Thickness on the Self-Lift-off of Thick GaN Epitaxial Layers

    International Nuclear Information System (INIS)

    Yugov, A. A.; Malahov, S. S.; Donskov, A. A.; Duhnovskii, M. P.; Knyazev, S. N.; Kozlova, Yu. P.; Yugova, T. G.; Belogorokhov, I. A.

    2016-01-01

    The effect of the type of substrate, sapphire substrate (c- and r-orientation) or GaN/Al_2O_3 template (c- and r-orientations), on the nitridation of an amorphous titanium nanolayer is shown. The effect of the titanium-nanolayer thickness on thick GaN epitaxial layer self-separation from the substrate is revealed. The titanium-nanolayer thickness at which thick GaN layer is reproducibly self-separated is within 20–40 nm.

  1. Thick film hydrogen sensor

    Science.gov (United States)

    Hoffheins, Barbara S.; Lauf, Robert J.

    1995-01-01

    A thick film hydrogen sensor element includes an essentially inert, electrically-insulating substrate having deposited thereon a thick film metallization forming at least two resistors. The metallization is a sintered composition of Pd and a sinterable binder such as glass frit. An essentially inert, electrically insulating, hydrogen impermeable passivation layer covers at least one of the resistors.

  2. Maternal obesity influences the relationship between location of neonate fat mass and total fat mass.

    Science.gov (United States)

    Hull, H R; Thornton, J; Paley, C; Navder, K; Gallagher, D

    2015-08-01

    It is suggested that maternal obesity perpetuates offspring obesity to future generations. To determine whether location of neonate fat mass (FM: central vs. peripheral) is related to total neonate FM and whether maternal obesity influences this relationship. Neonate body composition and skin-fold thicknesses were assessed in healthy neonates (n = 371; 1-3 days old). Linear regression models examined the relationship between total FM and location of FM (central vs. peripheral). Location of FM was calculated by skin-folds: peripheral was the sum of (biceps and triceps)/2 and central was represented by the subscapular skin-fold. A significant interaction was found for location of FM and maternal obesity. Holding all predictors constant, in offspring born to non-obese mothers, a 0.5 mm increase in central FM predicted a 15 g greater total FM, whereas a 0.5 mm increase in peripheral FM predicted a 66 g greater total FM. However, in offspring born to obese mothers, a 0.5 mm increase in central FM predicted a 56 g total FM, whereas a 0.5 mm increase in peripheral FM predicted a 14 g greater total FM. The relationship between total FM and location of FM is influenced by maternal obesity. © 2014 The Authors. Pediatric Obesity © 2014 World Obesity.

  3. Ultrasound cavitation versus cryolipolysis for non-invasive body contouring.

    Science.gov (United States)

    Mahmoud ELdesoky, Mohamed Taher; Mohamed Abutaleb, Enas ELsayed; Mohamed Mousa, Gihan Samir

    2015-08-24

    The demand for non-surgical and non-invasive devices is continuous and increasing. Such devices have gradually gained ground in the reduction of localised fat and the improvement of body contouring. The study aimed to compare the effects of ultrasound cavitation and cryolipolysis on localised abdominal fat. In total, 60 participants with a body mass index (BMI) over 30 kg/m 2 , whose age ranged between 25 and 45 years, were included. The participants were randomly assigned to three groups of 20 each, using ultrasound cavitation and diet, cryolipolysis and diet, and diet only (the control group), respectively. Measures were bodyweight, BMI, waist circumference and suprailiac skinfold were measured at the beginning of the study and 2 months later. The three groups showed significant improvements in all measured variables after 2 months. There was no statistically significant difference in bodyweight or in BMI among the groups after treatment. However, the groups using ultrasound cavitation and cryolipolysis showed better post-treatment improvement than the diet-only group in waist circumference and suprailiac skinfold. There was no statistically significant difference post-treatment between the cavitation and cryolipolysis groups in waist circumference or suprailiac skinfold. Both ultrasound cavitation and cryolipolysis are safe and effective for the reduction of abdominal fat thickness and for abdominal contouring. © 2015 The Australasian College of Dermatologists.

  4. The obesity paradox in elderly patients with heart failure: analysis of nutritional status.

    Science.gov (United States)

    Casas-Vara, Antonio; Santolaria, Francisco; Fernández-Bereciartúa, Ainhoa; González-Reimers, Emilio; García-Ochoa, Alfonso; Martínez-Riera, Antonio

    2012-06-01

    The obesity paradox refers to the improved survival of obese compared with non-obese elderly or diseased patients for reasons that are not clear. To assess the relative roles of fat and other factors in this improved survival, we analyzed the prognostic value of overweight and obesity elderly patients with heart failure (HF), controlling for other nutritional data such as midarm anthropometrics, serum proteins, and muscle strength. Two hundred forty-four patients (83.2 ± 0.5 y old) hospitalized for HF were included. A nutritional survey was performed in all patients. After discharge, the patients were followed up by telephone. Fourteen patients (5.7%) died during hospitalization. The median survival was 984 d. Patients with better nutritional status as assessed by the body mass index (BMI), subjective score, midarm muscle area, triceps skinfold thickness, handgrip, lymphocyte count, and serum albumin, prealbumin, and cholesterol levels showed better short- and long-term prognoses. Obese patients with a BMI above 30 kg/m(2) showed a better long-term prognosis than those with a BMI from 25 to 30 kg/m(2), those with a BMI from 20 to 25 kg/m(2), and those with a BMI lower than 20 kg/m(2). However, survival was not significantly related to a triceps skinfold thickness above the 95th percentile. Obese and overweight patients were younger and had better a nutritional status than those with a normal or decreased BMI as shown by the anthropometrics, subjective score, handgrip, lymphocyte count, hemoglobin, and serum albumin, prealbumin, and cholesterol levels. All the nutritional data correlated closely with each other. New York Heart Association class also correlated with nutrition-derived data: as the HF class increased, the nutritional status deteriorated. On multivariate analysis, to predict long-term survival, neither BMI nor triceps skinfold thickness showed an independent predictive value, whereas a larger midarm muscle area did. The obesity paradox was confirmed in

  5. Origami-Inspired Folding of Thick, Rigid Panels

    Science.gov (United States)

    Trease, Brian P.; Thomson, Mark W.; Sigel, Deborah A.; Walkemeyer, Phillip E.; Zirbel, Shannon; Howell, Larry; Lang, Robert

    2014-01-01

    To achieve power of 250 kW or greater, a large compression ratio of stowed-to-deployed area is needed. Origami folding patterns were used to inspire the folding of a solar array to achieve synchronous deployment; however, origami models are generally created for near-zero-thickness material. Panel thickness is one of the main challenges of origami-inspired design. Three origami-inspired folding techniques (flasher, square twist, and map fold) were created with rigid panels and hinges. Hinge components are added to the model to enable folding of thick, rigid materials. Origami models are created assuming zero (or near zero) thickness. When a material with finite thickness is used, the panels are required to bend around an increasingly thick fold as they move away from the center of the model. The two approaches for dealing with material thickness are to use membrane hinges to connect the panels, or to add panel hinges, or hinges of the same thickness, at an appropriate width to enable folding.

  6. Predictor Variables for Marathon Race Time in Recreational Female Runners

    OpenAIRE

    Schmid, Wiebke; Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Rüst, Christoph Alexander; Rosemann, Thomas; Lepers, Romuald

    2012-01-01

    Purpose We intended to determine predictor variables of anthropometry and training for marathon race time in recreational female runners in order to predict marathon race time for future novice female runners. Methods Anthropometric characteristics such as body mass, body height, body mass index, circumferences of limbs, thicknesses of skin-folds and body fat as well as training variables such as volume and speed in running training were related to marathon race time using bi- and multi-varia...

  7. Sedentary Behavior Is Independently Related to Fat Mass among Children and Adolescents in South China

    OpenAIRE

    Xue, Hongmei; Tian, Guo; Duan, Ruonan; Quan, Liming; Zhao, Li; Yang, Min; Libuda, Lars; Muckelbauer, Rebecca; Cheng, Guo

    2016-01-01

    We aim to explore the independent associations of sedentary behaviors (SB) with body mass distribution among Chinese children. Data on the screen-based sedentary time (television viewing and computer use) and doing homework, physical activities and dietary intake of 1586 Chinese children (50.3% girls) aged 7–15 years were obtained through validated questionnaires. Skin-fold thickness, body height, and weight were measured to calculate percent body fat (%BF), fat mass index (FMI), and fat-free...

  8. Fatigue behavior of thick composite single lap joints

    Energy Technology Data Exchange (ETDEWEB)

    Tang, J.H.; Sridhar, I.; Srikanth, N. [Nanyang Technological Univ., Singapore (Singapore)

    2012-07-01

    In consideration of bondline thickness variability, in bonded joints where thick adherend is adopted, relative thick adhesive layer (2-5 mm) is preferable. This paper aims to give some insight in fatigue strength of adhesively bonded structures involving thick adherend coupled with thick adhesive layer. Single lap joints with nominal adherend thickness of 8 mm and two different nominal thicknesses (2.5 mm and 5.5 mm) were made and tested under fatigue loading. The failure mode exhibits always a tendency for interfacial initiation, followed by interlaminar separation. Fatigue strength for higher adhesive thickness is found to be lower. (Author)

  9. Dual beam x-ray thickness gauge

    International Nuclear Information System (INIS)

    Allport, J.J.

    1977-01-01

    The apparatus and method for continuous measurement of thickness of a sheet at a rolling mill or the like without contacting the sheet are described. A system directing radiation through the sheet in two energy bands and providing a measure of change in composition of the material as it passes the thickness gauging station is included. A system providing for changing the absorption coefficient of the material in the thickness measurement as a function of the change in composition so that the measured thickness is substantially independent of variations in composition is described

  10. Uncertainties in thick-target PIXE analysis

    International Nuclear Information System (INIS)

    Campbell, J.L.; Cookson, J.A.; Paul, H.

    1983-01-01

    Thick-target PIXE analysis insolves uncertainties arising from the calculation of thick-target X-ray production in addition to the usual PIXE uncertainties. The calculation demands knowledge of ionization cross-sections, stopping powers and photon attenuation coefficients. Information on these is reviewed critically and a computational method is used to estimate the uncertainties transmitted from this data base into results of thick-target PIXE analyses with reference to particular specimen types using beams of 2-3 MeV protons. A detailed assessment of the accuracy of thick-target PIXE is presented. (orig.)

  11. Study on the ionization chamber for thickness measurement

    International Nuclear Information System (INIS)

    Xue Shili; Miao Qiangwen

    1988-01-01

    The principle, construction and performances of ionization chambers for measuring the thickness of metal and nonmetal materials are introduced. With them the thickness of thin materials (thickness ranging from 10 to 6000 g/m 2 ), the surface layer thickness of composed materials and the thickness of steel plate (thickness ranging from 0 to 32 kg/m 2 ) are measured effectively

  12. Body mass index and skinfolds as indicators of obesity in schoolchildren aged 8 to 10 years

    Directory of Open Access Journals (Sweden)

    João Paulo Buraneli Mantoan

    2008-06-01

    Full Text Available The aim of this study was to compare the concordance of two obesity indicators, BMI and % body fat in boys and girls. Therefore, 100 girls and 100 boys, with ages ranging from 8 to 10 years, were submitted to anthropometric measurements for subsequent calculation of Body Mass Index (BMI and % body fat, both as obesity indicators. The variables were analyzed with relation to the reference criteria proposed by Williams et al and Cole et al. The results were then analyzed with the kappa index, elucidating that 79% of the boys and 85% of the girls were classified simultaneously by both procedures. The kappa index indicated a moderate agreement between the two obesity indicators for obese and non-obese classification. However, our data demonstrated that 21% of the boys and 15% of the girls showed normal weight according to BMI, but were classified as obese according to the % body fat. The results show that BMI, when compared with skinfolds, had moderate agreement in children from 8 to 10 years old for detecting obesity. ResumoO objetivo deste estudo foi comparar a concordância entre dois indicadores de obesidade, IMC e percentual de gordura, em escolares de ambos os sexos. Para tanto, 100 meninas e 100 meninos de 8 a 10 anos, alunos do ensino fundamental do município de Londrina, foram submetidos a medidas antropométricas para subseqüente cálculo do Índice de Massa Corporal (IMC e percentual de gordura como indicadores de obesidade. As variáveis foram analisadas em relação aos critérios de referência apresentados por Williams et al e Cole et al. Os resultados foram analisados pelo índice Kappa, evidenciando que 79% dos meninos e 85% das meninas foram classificados simultaneamente pelos dois procedimentos. Uma concordância moderada entre os dois indicadores de obesidade na classificação para meninos e meninas foi evidenciada (kappa=0,43 e 0,50, respectivamente. Entretanto, os dados encontrados demonstraram que 21% dos meninos e 15% das

  13. Thick Toenails

    Science.gov (United States)

    ... in individuals with nail fungus (onychomycosis), psoriasis and hypothyroidism. Those who have problems with the thickness of their toenails should consult a foot and ankle surgeon for proper diagnosis and treatment. Find an ACFAS Physician Search Search Tools Find ...

  14. doped ZnO thick film resistors

    Indian Academy of Sciences (India)

    The characterization and ethanol gas sensing properties of pure and doped ZnO thick films were investigated. Thick films of pure zinc oxide were prepared by the screen printing technique. Pure zinc oxide was almost insensitive to ethanol. Thick films of Al2O3 (1 wt%) doped ZnO were observed to be highly sensitive to ...

  15. A method to measure the mean thickness and non-uniformity of non-uniform thin film by alpha-ray thickness gauge

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Yoshida, Makoto; Watanabe, Tamaki

    1977-01-01

    The α-ray thickness gauge is used to measure non-destructively the thicknesses of thin films, and up to the present day, a thin film with uniform thickness is only taken up as the object of α-ray thickness gauge. When the thickness is determined from the displacement between the absorption curves in the presence and absence of thin film, the absorption curve must be displaced in parallel. When many uniform particles were dispersed as sample, the shape of the absorption curve was calculated as the sum of many absorption curves corresponding to the thin films with different thicknesses. By the comparison of the calculated and measured absorption curves, the number of particles, or the mean superficial density can be determined. This means the extension of thickness measurement from uniform to non-uniform films. Furthermore, these particle models being applied to non-uniform thin film, the possibility of measuring the mean thickness and non-uniformity was discussed. As the result, if the maximum difference of the thickness was more than 0.2 mg/cm 2 , the nonuniformity was considered to distinguish by the usual equipment. In this paper, an α-ray thickness gauge using the absorption curve method was treated, but one can apply this easily to an α-ray thickness gauge using α-ray energy spectra before and after the penetration of thin film. (auth.)

  16. How accurate are estimates of glacier ice thickness? Results from ITMIX, the Ice Thickness Models Intercomparison eXperiment

    DEFF Research Database (Denmark)

    Farinotti, Daniel; Brinkerhoff, Douglas J.; Clarke, Garry K. C.

    2017-01-01

    Knowledge of the ice thickness distribution of glaciers and ice caps is an important prerequisite for many glaciological and hydrological investigations. A wealth of approaches has recently been presented for inferring ice thickness from characteristics of the surface. With the Ice Thickness Models...

  17. Body image dissatisfaction among rural and urban adolescents

    Directory of Open Access Journals (Sweden)

    M.F. Glaner

    2009-01-01

    Full Text Available To identify the prevalence of body image dissatisfaction among adolescents living in rural and urban areas, and to analyze the influence of demographic and anthropometric variables on body image dissatisfaction. A total of 629 adolescents aged 13 to 17 years from urban and rural areas participated in the study. Demographic variables (gender, age, area of residence, anthropometric measurements (body weight, height, skinfold thickness and body image data were collected. BMI (underweight: 25 kg/m² and the sum of two skinfold thicknesses, Σ2SF (girls: low: 36 mm; boys: low: 25 mm were then calculated. The prevalence of body image dissatisfaction was similar (p≥0,05 among rural (64,2% and urban adolescents (62,8%. Boys wished to increase the size of their body silhouette (41,3%, whereas girls wished to reduce it (50,5% (p<0,001. Adolescents with low and excess weight based on BMI and with high Σ2SF presented a 3,14, 8,45 and 2,08 times higher chance of body image dissatisfaction, respectively. A high prevalence of body image dissatisfaction was observed among adolescents from rural and urban areas. An unhealthy nutritional status and body adiposity increase the chances of body image dissatisfaction. These findings emphasize the social pressure on girls to remain slim and on boys to attain an athletic body.

  18. The effects of a reformer Pilates program on body composition and morphological characteristics in active women after a detraining period.

    Science.gov (United States)

    Vaquero-Cristóbal, Raquel; Alacid, Fernando; Esparza-Ros, Francisco; López-Plaza, Daniel; Muyor, José M; López-Miñarro, Pedro A

    2016-10-01

    The aim of this quasi-experimental pilot study was to explore the effects of a reformer Pilates program on the anthropometry, body composition, and somatotype of active adult women after a short non-exercise period. Twenty-eight women (mean age: 40.21 ± standard deviation of 8.12 years old) with one to three years of reformer Pilates experience participated in the study. The women participated in a reformer Pilates program for 16 weeks (one hour, twice per week) after 4 weeks of detraining (summer holidays) in 2012. The International Society for the Advancement of Kinanthropometry full profile was assessed before and after the intervention program. Significant decreases (p ≤ 0.05) from pre- to post-program were observed for triceps, iliac crest, supraspinale, abdominal, front thigh and medial calf skinfold thicknesses, six and eight skinfold thickness sums, forearm and ankle girths, waist/hip ratio, endomorphy, and fat mass. Significant increases (p ≤ .05) were observed for corrected arm, corrected calf girths, and muscle mass. Generally, women showed a mesomorphic endomorph (endomorphy predominant) and mesomorph-endomorph (endomorphy and mesomorphy predominant) in the pre- and posttests, respectively. In conclusion, the practice of reformer Pilates was associated with healthy changes in anthropometric parameters, body composition, and somatotype in Pilates-experienced women after 4 weeks of no physical exercise.

  19. Survey of Anthropometric Indices Addicts due to the History of Addiction and Substance Abuse in Qom Province, 2014

    Directory of Open Access Journals (Sweden)

    Mohammad Hozoori

    2017-02-01

    Full Text Available Background: Substance abuse has significant impact on nutritional status. Due to the increased malnutrition during drug use and withdrawal, this study aimed at assessing the anthropometric indices in individuals referring to drug treatment centers in Qom. Methods: In this descriptive-analytical study, 329 addicted individuals referring to addiction centers in Qom were randomly selected. A questionnaire was used with three parts including demographic characteristics, drug abuse history, and anthropometric indices including measurement of height, weight, waist circumference, arm circumference, and skinfold thickness in triceps and calf muscles. Results: The participants consisted of 328 men and only one woman, 29% of whom were in detoxification. The participants' mean age was 39.0 ± 7.1 years. The first and most-frequently used drug was opium. All anthropometric indices were associated with the consumption of opium substances and drug use was associated significantly with some parameters. With the exception of skinfold thickness in the calf, all the indices were affected by the type of consumed substances. The opium addicts had a higher body mass index compared with other drug users. Conclusions: Due to the importance of nutrition status in drug abusers' health and their lack of self-care, careful monitoring and evaluation of dietary intake, as well as nutrition status can play important roles in the rehabilitation of these individuals and help to prevent from reappearance of these habits.

  20. An anthropometric model to estimate neonatal fat mass using air displacement plethysmography

    Directory of Open Access Journals (Sweden)

    Deierlein Andrea L

    2012-03-01

    Full Text Available Abstract Background Current validated neonatal body composition methods are limited/impractical for use outside of a clinical setting because they are labor intensive, time consuming, and require expensive equipment. The purpose of this study was to develop an anthropometric model to estimate neonatal fat mass (kg using an air displacement plethysmography (PEA POD® Infant Body Composition System as the criterion. Methods A total of 128 healthy term infants, 60 females and 68 males, from a multiethnic cohort were included in the analyses. Gender, race/ethnicity, gestational age, age (in days, anthropometric measurements of weight, length, abdominal circumference, skin-fold thicknesses (triceps, biceps, sub scapular, and thigh, and body composition by PEA POD® were collected within 1-3 days of birth. Backward stepwise linear regression was used to determine the model that best predicted neonatal fat mass. Results The statistical model that best predicted neonatal fat mass (kg was: -0.012 -0.064*gender + 0.024*day of measurement post-delivery -0.150*weight (kg + 0.055*weight (kg2 + 0.046*ethnicity + 0.020*sum of three skin-fold thicknesses (triceps, sub scapular, and thigh; R2 = 0.81, MSE = 0.08 kg. Conclusions Our anthropometric model explained 81% of the variance in neonatal fat mass. Future studies with a greater variety of neonatal anthropometric measurements may provide equations that explain more of the variance.

  1. Thick brane solutions

    International Nuclear Information System (INIS)

    Dzhunushaliev, Vladimir; Minamitsuji, Masato; Folomeev, Vladimir

    2010-01-01

    This paper gives a comprehensive review on thick brane solutions and related topics. Such models have attracted much attention from many aspects since the birth of the brane world scenario. In many works, it has been usually assumed that a brane is an infinitely thin object; however, in more general situations, one can no longer assume this. It is also widely considered that more fundamental theories such as string theory would have a minimal length scale. Many multidimensional field theories coupled to gravitation have exact solutions of gravitating topological defects, which can represent our brane world. The inclusion of brane thickness can realize a variety of possible brane world models. Given our understanding, the known solutions can be classified into topologically non-trivial solutions and trivial ones. The former class contains solutions of a single scalar (domain walls), multi-scalar, gauge-Higgs (vortices), Weyl gravity and so on. As an example of the latter class, we consider solutions of two interacting scalar fields. Approaches to obtain cosmological equations in the thick brane world are reviewed. Solutions with spatially extended branes (S-branes) and those with an extra time-like direction are also discussed.

  2. [Endoscopic full-thickness resection].

    Science.gov (United States)

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  3. Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

    Energy Technology Data Exchange (ETDEWEB)

    Humbert, Ludovic, E-mail: ludohumberto@gmail.com [Galgo Medical, Barcelona 08036 (Spain); Hazrati Marangalou, Javad; Rietbergen, Bert van [Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB (Netherlands); Río Barquero, Luis Miguel del [CETIR Centre Medic, Barcelona 08029 (Spain); Lenthe, G. Harry van [Biomechanics Section, KU Leuven–University of Leuven, Leuven 3001 (Belgium)

    2016-04-15

    Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed. Methods: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context. Results: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (−18 ± 92 mg/cm{sup 3}) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm{sup 3}), and 0.10 ± 0.24 mm (−10 ± 115 mg/cm{sup 3}) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm{sup 3}). A trend for the

  4. Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

    International Nuclear Information System (INIS)

    Humbert, Ludovic; Hazrati Marangalou, Javad; Rietbergen, Bert van; Río Barquero, Luis Miguel del; Lenthe, G. Harry van

    2016-01-01

    Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed. Methods: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context. Results: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (−18 ± 92 mg/cm"3) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm"3), and 0.10 ± 0.24 mm (−10 ± 115 mg/cm"3) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm"3). A trend for the cortical thickness and

  5. Optimum target thickness for polarimeters

    International Nuclear Information System (INIS)

    Sitnik, I.M.

    2003-01-01

    Polarimeters with thick targets are a tool to measure the proton polarization. But the question about the optimum target thickness is still the subject of discussion. An attempt to calculate the most common parameters concerning this problem, in a few GeV region, is made

  6. Monitoring production target thickness

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1993-01-01

    Pion and muon production targets at the Clinton P. Anderson Meson Physics Facility consist of rotating graphite wheels. The previous target thickness monitoring Procedure scanned the target across a reduced intensity beam to determine beam center. The fractional loss in current across the centered target gave a measure of target thickness. This procedure, however, required interruption of beam delivery to experiments and frequently indicated a different fractional loss than at normal beam currents. The new monitoring Procedure compares integrated ups and downs toroid current monitor readings. The current monitors are read once per minute and the integral of readings are logged once per eight-hour shift. Changes in the upstream to downstream fractional difference provide a nonintrusive continuous measurement of target thickness under nominal operational conditions. Target scans are now done only when new targets are installed or when unexplained changes in the current monitor data are observed

  7. A thick placenta: a predictor of adverse pregnancy outcomes.

    Science.gov (United States)

    Miwa, Ichiro; Sase, Masakatsu; Torii, Mayumi; Sanai, Hiromi; Nakamura, Yasuhiko; Ueda, Kazuyuki

    2014-01-01

    The aim of this study is to evaluate the efficacy of an ultrasonographic measurement of placental thickness and the correlation of a thick placenta with adverse perinatal outcome. Placental thickness was measured in single gravidas, 16 to 40 weeks of gestation, between 2005 and 2009. Placentas were considered to be thick if their measured thickness were above the 95th percentile for gestational age. The incidence of thick placentas was 4.3% (138/3,183). Perinatal morbidity and neonatal conditions were worse in cases with thick placenta rather than without thick placenta. Ultrasonographic measurement of placental thickness is a simple method to estimate placental size. Thick placenta may be a useful predictor of adverse pregnancy outcomes.

  8. Influence of Thickness on Ethanol Sensing Characteristics of Doctor-bladed Thick Film from Flame-made ZnO Nanoparticles

    Directory of Open Access Journals (Sweden)

    Sukon Phanichphant

    2007-02-01

    Full Text Available ZnO nanoparticles were produced by flame spray pyrolysis (FSP using zincnaphthenate as a precursor dissolved in toluene/acetonitrile (80/20 vol%. The particleproperties were analyzed by XRD, BET, and HR-TEM. The sensing films were produced bymixing the particles into an organic paste composed of terpineol and ethyl cellulose as avehicle binder and were fabricated by doctor-blade technique with various thicknesses (5,10, 15 μm. The morphology of the sensing films was analyzed by SEM and EDS analyses.The gas sensing characteristics to ethanol (25-250 ppm were evaluated as a function of filmthickness at 400°C in dry air. The relationship between thickness and ethanol sensingcharacteristics of ZnO thick film on Al2O3 substrate interdigitated with Au electrodes wereinvestigated. The effects of film thickness, as well as the cracking phenomenon, though,many cracks were observed for thicker sensing films. Crack widths increased withincreasing film thickness. The film thickness, cracking and ethanol concentration havesignificant effect on the sensing characteristics. The sensing characteristics with variousthicknesses were compared, showing the tendency of the sensitivity to ethanol decreasedwith increasing film thickness and response time. The relationship between gas sensingproperties and film thickness was discussed on the basis of diffusively and reactivity of thegases inside the oxide films. The thinnest sensing film (5 μm showed the highest sensitivityand the fastest response time (within seconds.

  9. The influence of fiber thickness, wall thickness and gap distance on the spiral nanofibrous scaffolds for bone tissue engineering

    International Nuclear Information System (INIS)

    Wang Junping; Shah, Ami; Yu Xiaojun

    2011-01-01

    We have developed a 3D nanofibrous spiral scaffold for bone tissue engineering which has shown enhanced cell attachment, proliferation and differentiation compared to traditional cylindrical scaffolds due to the spiral structures and the nanofiber incorporation. Some important parameters of these spiral scaffolds including gap distance, wall thickness and especially fiber thickness are crucial to the performance of the spiral structured scaffolds. In this study, we investigated the fiber thickness, gap distance and wall thickness of the spiral structure on the behavior of osteoblast cells. The human osteoblast cells are seeded on spiral structured scaffolds with various fiber thickness, gap distance and wall thickness and cell attachment, proliferation, differentiation and mineralized matrix deposition on the scaffolds are evaluated. It was found that increasing the thickness of nanofiber layer not only limited the cell infiltration into the scaffolds, but also restrained the osteoblastic cell phenotype development. Moreover, the geometric effect studies indicated that scaffolds with the thinner wall and gap distance 0.2 mm show the best bioactivity for osteoblasts.

  10. Thickness measurement by using cepstrum ultrasonic signal processing

    International Nuclear Information System (INIS)

    Choi, Young Chul; Yoon, Chan Hoon; Choi, Heui Joo; Park, Jong Sun

    2014-01-01

    Ultrasonic thickness measurement is a non-destructive method to measure the local thickness of a solid element, based on the time taken for an ultrasound wave to return to the surface. When an element is very thin, it is difficult to measure thickness with the conventional ultrasonic thickness method. This is because the method measures the time delay by using the peak of a pulse, and the pulses overlap. To solve this problem, we propose a method for measuring thickness by using the power cepstrum and the minimum variance cepstrum. Because the cepstrums processing can divides the ultrasound into an impulse train and transfer function, where the period of the impulse train is the traversal time, the thickness can be measured exactly. To verify the proposed method, we performed experiments with steel and, acrylic plates of variable thickness. The conventional method is not able to estimate the thickness, because of the overlapping pulses. However, the cepstrum ultrasonic signal processing that divides a pulse into an impulse and a transfer function can measure the thickness exactly.

  11. Equilibrium helium film in the thick film limit

    International Nuclear Information System (INIS)

    Klier, J.; Schletterer, F.; Leiderer, P.; Shikin, V.

    2003-01-01

    For the thickness of a liquid or solid quantum film, like liquid helium or solid hydrogen, there exist still open questions about how the film thickness develops in certain limits. One of these is the thick film limit, i.e., the crossover from the thick film to bulk. We have performed measurements in this range using the surface plasmon resonance technique and an evaporated Ag film deposited on glass as substrate. The thickness of the adsorbed helium film is varied by changing the distance h of the bulk reservoir to the surface of the substrate. In the limiting case, when h > 0, the film thickness approaches about 100 nm following the van der Waals law in the retarded regime. The film thickness and its dependence on h is precisely determined and theoretically modeled. The equilibrium film thickness behaviour is discussed in detail. The agreement between theory and experiment is very good

  12. Obesity Related Indices for Screening of Obesity in Adolescents

    Directory of Open Access Journals (Sweden)

    Amit Sohani

    2015-09-01

    Full Text Available Background: Obesity is a fast growing problem in the developing countries like India and is now known to be associated with increased health risk. Realizing the fact that the obesity in adolescent age group does not receive the deserved attention in the prevention and control programme, the present study was undertaken on 585 adolescent subjects studying in one college and three schools. Aims and Objectives: 1. To study the prevalence of overweight and obesity in adolescent population. 2. To find the association of body mass index (BMI with important parameters like skin fold thickness, waist circumference and waist to hip ratio. Methods: It was a cross sectional observational study. The study population was school and college going adolescents in the age group of 11-19 years. The estimated sample size for present study is 585 students. The subjects were screened by body mass index, skin fold thickness, waist circumference and waist to hip ratio. Results: The prevalence of overweight and obesity was 19.14% and 4.44% respectively. It was found that there was strong association between the waist circumference with overweight and obesity. Similarly a strong association between waist to hip ratio with overweight and obesity has been found. Also it was found that there was a strong association between skin fold thickness with overweight and obesity. Skin-fold thickness has more sensitivity as compared to waist circumference and waist to hip ratio. Waist to hip ratio has got maximum specificity amongst all but when both sensitivity and specificity criteria are considered together waist circumference stands out. Conclusion: It was found that the prevalence of overweight and obesity was 19.14% and 4.44% respectively. Skin-fold thickness has more sensitivity as compared waist circumference and waist to hip ratio. Waist to hip ratio has got maximum specificity. When sensitivity and specificity criteria are considered together waist circumference can be

  13. Choroidal thickness in traumatic optic neuropathy.

    Science.gov (United States)

    Lee, Ju-Yeun; Eo, Doo-Ri; Park, Kyung-Ah; Oh, Sei Yeul

    2017-12-01

    To examine the choroidal thickness in patients with indirect traumatic optic neuropathy (TON) Methods: Patients with unilateral traumatic optic neuropathy over a period of 4 years were included in this study. Horizontal and vertical enhanced-depth imaging (EDI) from spectral-domain optical coherence tomography (SD-OCT) scans of the fovea were obtained in patients with unilateral TON within 2 weeks of injury. The main outcome measure was the choroidal thickness at nine locations. The choroidal thickness was compared between affected and unaffected eyes in the TON group, and the mean difference in the choroidal thickness in both eyes was compared between TON and control groups. A total of 16 patients and 20 control subjects were included. The choroidal thickness at horizontal, vertical and average subfoveal, inner temporal, and outer inferior locations was significantly thicker (13-23%) in affected eyes than in unaffected fellow eyes (p = 0.042, 0.046, 0.024, 0.013, 0.018, and 0.027, respectively). The mean difference value between choroidal thickness measurements in both eyes was significantly larger in the TON group than in the control group at the horizontal, vertical and average subfoveal, inner temporal, inner nasal, inner superior, inner inferior, and outer superior locations (p = 0.001, 0.011,  0.05). Eyes affected by TON showed a regionally thicker choroid than unaffected fellow eye. This thick choroid might be due to impaired blood circulation and vascular remodeling of the optic nerve head and choroid. These results help to better understand the pathophysiology of TON.

  14. Mechanical Properties of Additively Manufactured Thick Honeycombs

    Directory of Open Access Journals (Sweden)

    Reza Hedayati

    2016-07-01

    Full Text Available Honeycombs resemble the structure of a number of natural and biological materials such as cancellous bone, wood, and cork. Thick honeycomb could be also used for energy absorption applications. Moreover, studying the mechanical behavior of honeycombs under in-plane loading could help understanding the mechanical behavior of more complex 3D tessellated structures such as porous biomaterials. In this paper, we study the mechanical behavior of thick honeycombs made using additive manufacturing techniques that allow for fabrication of honeycombs with arbitrary and precisely controlled thickness. Thick honeycombs with different wall thicknesses were produced from polylactic acid (PLA using fused deposition modelling, i.e., an additive manufacturing technique. The samples were mechanically tested in-plane under compression to determine their mechanical properties. We also obtained exact analytical solutions for the stiffness matrix of thick hexagonal honeycombs using both Euler-Bernoulli and Timoshenko beam theories. The stiffness matrix was then used to derive analytical relationships that describe the elastic modulus, yield stress, and Poisson’s ratio of thick honeycombs. Finite element models were also built for computational analysis of the mechanical behavior of thick honeycombs under compression. The mechanical properties obtained using our analytical relationships were compared with experimental observations and computational results as well as with analytical solutions available in the literature. It was found that the analytical solutions presented here are in good agreement with experimental and computational results even for very thick honeycombs, whereas the analytical solutions available in the literature show a large deviation from experimental observation, computational results, and our analytical solutions.

  15. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    Science.gov (United States)

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade

  16. The optimum lead thickness for lead-activation detectors

    International Nuclear Information System (INIS)

    Si Fenni; Hu Qingyuan

    2009-01-01

    The optimum lead thickness for lead-activation detectors has been studied in this paper. First existence of the optimum lead thickness is explained theoretically. Then the optimum lead thickness is obtained by two methods, MCNP5 calculation and mathematical estimation. At last factors which affect the optimum lead thickness are discussed. It turns out that the optimum lead thickness is irrelevant to incident neutron energies. It is recommended 2.5 cm generally.

  17. Thick vortices in SU(2) lattice gauge theory

    OpenAIRE

    Cheluvaraja, Srinath

    2004-01-01

    Three dimensional SU(2) lattice gauge theory is studied after eliminating thin monopoles and the smallest thick monopoles. Kinematically this constraint allows the formation of thick vortex loops which produce Z(2) fluctuations at longer length scales. The thick vortex loops are identified in a three dimensional simulation. A condensate of thick vortices persists even after the thin vortices have all disappeared. The thick vortices decouple at a slightly lower temperature (higher beta) than t...

  18. Razão peso/comprimento: um bom indicador do estado nutricional em recém-nascidos a termo? Weight/length ratio: is it a good index to assess the nutritional status of full-term newborns?

    Directory of Open Access Journals (Sweden)

    Taciana D. de A. Braga

    2002-01-01

    Full Text Available Objetivo: uma avaliação acurada do estado nutricional da criança ao nascer tem importância na identificação precoce de eventos mórbidos relacionados com a aceleração ou desaceleração do crescimento intra-útero. Os índices antropométricos resultantes das razões entre o peso e o comprimento e aqueles que resultam da razão entre o perímetro braquial e o perímetro cefálico podem ser uma alternativa, dentro da antropometria, para esse fim. O objetivo principal deste estudo foi verificar o grau de correlação entre a prega cutânea triciptal e os índices antropométricos - índice ponderal de Rohrer, índice de massa corpórea, razão peso/comprimento, razão perímetro braquial/perímetro cefálico - utilizados como critério de avaliação do estado nutricional de recém-nascidos. Métodos: realizou-se um estudo de corte transversal em 390 recém-nascidos a termo na maternidade do Centro de Atenção à Saúde da Mulher do Instituto Materno-Infantil de Pernambuco, no período de maio a julho de 1999. Os recém-nascidos foram avaliados quanto ao peso, comprimento, perímetros cefálico e braquial e prega cutânea triciptal. Resultados: os resultados mostraram que os índices antropométricos apresentaram correlação significante com a prega cutânea triciptal, tendo sido a razão simples entre o peso e o comprimento aquele que se correlacionou mais fortemente (r = 0,63; p Objective: An accurate assessment of the nutritional status of an infant at birth is very important, since it provides information on early identification of pathological events related to intrauterine growth acceleration or retardation. Anthropometric ratios such as weight/length and mid-arm circumference/head circumference may be used as alternative tools for this purpose. The main objective of this study was to verify the correlation between triceps skinfold thickness with Rohrer Index, Body Mass Index, weight/length ratio, and mid-arm circumference

  19. A semi-analytical solution for elastic analysis of rotating thick cylindrical shells with variable thickness using disk form multilayers.

    Science.gov (United States)

    Zamani Nejad, Mohammad; Jabbari, Mehdi; Ghannad, Mehdi

    2014-01-01

    Using disk form multilayers, a semi-analytical solution has been derived for determination of displacements and stresses in a rotating cylindrical shell with variable thickness under uniform pressure. The thick cylinder is divided into disk form layers form with their thickness corresponding to the thickness of the cylinder. Due to the existence of shear stress in the thick cylindrical shell with variable thickness, the equations governing disk layers are obtained based on first-order shear deformation theory (FSDT). These equations are in the form of a set of general differential equations. Given that the cylinder is divided into n disks, n sets of differential equations are obtained. The solution of this set of equations, applying the boundary conditions and continuity conditions between the layers, yields displacements and stresses. A numerical solution using finite element method (FEM) is also presented and good agreement was found.

  20. A Semi-Analytical Solution for Elastic Analysis of Rotating Thick Cylindrical Shells with Variable Thickness Using Disk Form Multilayers

    Directory of Open Access Journals (Sweden)

    Mohammad Zamani Nejad

    2014-01-01

    Full Text Available Using disk form multilayers, a semi-analytical solution has been derived for determination of displacements and stresses in a rotating cylindrical shell with variable thickness under uniform pressure. The thick cylinder is divided into disk form layers form with their thickness corresponding to the thickness of the cylinder. Due to the existence of shear stress in the thick cylindrical shell with variable thickness, the equations governing disk layers are obtained based on first-order shear deformation theory (FSDT. These equations are in the form of a set of general differential equations. Given that the cylinder is divided into n disks, n sets of differential equations are obtained. The solution of this set of equations, applying the boundary conditions and continuity conditions between the layers, yields displacements and stresses. A numerical solution using finite element method (FEM is also presented and good agreement was found.

  1. Prospective randomized comparison of scar appearances between cograft of acellular dermal matrix with autologous split-thickness skin and autologous split-thickness skin graft alone for full-thickness skin defects of the extremities.

    Science.gov (United States)

    Yi, Ju Won; Kim, Jae Kwang

    2015-03-01

    The purpose of this study was to evaluate the clinical outcomes of cografting of acellular dermal matrix with autologous split-thickness skin and autologous split-thickness skin graft alone for full-thickness skin defects on the extremities. In this prospective randomized study, 19 consecutive patients with full-thickness skin defects on the extremities following trauma underwent grafting using either cograft of acellular dermal matrix with autologous split-thickness skin graft (nine patients, group A) or autologous split-thickness skin graft alone (10 patients, group B) from June of 2011 to December of 2012. The postoperative evaluations included observation of complications (including graft necrosis, graft detachment, or seroma formation) and Vancouver Scar Scale score. No statistically significant difference was found regarding complications, including graft necrosis, graft detachment, or seroma formation. At week 8, significantly lower Vancouver Scar Scale scores for vascularity, pliability, height, and total score were found in group A compared with group B. At week 12, lower scores for pliability and height and total scores were identified in group A compared with group B. For cases with traumatic full-thickness skin defects on the extremities, a statistically significant better result was achieved with cograft of acellular dermal matrix with autologous split-thickness skin graft than with autologous split-thickness skin graft alone in terms of Vancouver Scar Scale score. Therapeutic, II.

  2. Macular thickness and volume in the elderly

    DEFF Research Database (Denmark)

    Subhi, Yousif; Forshaw, Thomas; Sørensen, Torben Lykke

    2016-01-01

    manifests in the macula of the elderly focusing on clinical relevant measures that are thicknesses and volumes of different macular areas. Ageing seems to increase center point foveal thickness. Ageing does not seem to change the center subfield thickness significantly. Ageing decreases the inner and outer...

  3. Graph Treewidth and Geometric Thickness Parameters

    OpenAIRE

    Dujmović, Vida; Wood, David R.

    2005-01-01

    Consider a drawing of a graph $G$ in the plane such that crossing edges are coloured differently. The minimum number of colours, taken over all drawings of $G$, is the classical graph parameter "thickness". By restricting the edges to be straight, we obtain the "geometric thickness". By further restricting the vertices to be in convex position, we obtain the "book thickness". This paper studies the relationship between these parameters and treewidth. Our first main result states that for grap...

  4. Does cement mantle thickness really matter?

    OpenAIRE

    Caruana, J.

    2008-01-01

    The thickness of the cement mantle around the femoral component of total hip replacements is a contributing factor to aseptic loosening and revision. Nevertheless, various designs of stems and surgical tooling lead to cement mantles of differing thicknesses. This thesis is concerned with variability in cement thickness around the Stanmore Hip, due to surgical approach, broach size and stem orientation, and its effects on stress and cracking in the cement. The extent to which cement mantle thi...

  5. Radiation transmission pipe thickness measurement system

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  6. Characteristics of the thick, compound refractive lens

    International Nuclear Information System (INIS)

    Pantell, Richard H.; Feinstein, Joseph; Beguiristain, H. Raul; Piestrup, Melvin A.; Gary, Charles K.; Cremer, Jay T.

    2003-01-01

    A compound refractive lens (CRL), consisting of a series of N closely spaced lens elements each of which contributes a small fraction of the total focusing, can be used to focus x rays or neutrons. The thickness of a CRL can be comparable to its focal length, whereupon a thick-lens analysis must be performed. In contrast with the conventional optical lens, where the ray inside the lens follows a straight line, the ray inside the CRL is continually changing direction because of the multiple refracting surfaces. Thus the matrix representation for the thick CRL is quite different from that for the thick optical lens. Principal planes can be defined such that the thick-lens matrix can be converted to that of a thin lens. For a thick lens the focal length is greater than for a thin lens with the same lens curvature, but this lengthening effect is less for the CRL than for the conventional optical lens

  7. Uncertainty estimation of ultrasonic thickness measurement

    International Nuclear Information System (INIS)

    Yassir Yassen, Abdul Razak Daud; Mohammad Pauzi Ismail; Abdul Aziz Jemain

    2009-01-01

    The most important factor that should be taken into consideration when selecting ultrasonic thickness measurement technique is its reliability. Only when the uncertainty of a measurement results is known, it may be judged if the result is adequate for intended purpose. The objective of this study is to model the ultrasonic thickness measurement function, to identify the most contributing input uncertainty components, and to estimate the uncertainty of the ultrasonic thickness measurement results. We assumed that there are five error sources significantly contribute to the final error, these sources are calibration velocity, transit time, zero offset, measurement repeatability and resolution, by applying the propagation of uncertainty law to the model function, a combined uncertainty of the ultrasonic thickness measurement was obtained. In this study the modeling function of ultrasonic thickness measurement was derived. By using this model the estimation of the uncertainty of the final output result was found to be reliable. It was also found that the most contributing input uncertainty components are calibration velocity, transit time linearity and zero offset. (author)

  8. Quantitative estimation of myocardial thickness by the wall thickness map with Tl-201 myocardial SPECT and its clinical use

    International Nuclear Information System (INIS)

    Sekiai, Yasuhiro; Sawai, Michihiko; Murayama, Susumu

    1988-01-01

    To estimate the wall thickness of left ventricular myocardium objectively and quantitatively, we adopted the device of wall thickness map (WTM) with Tl-201 myocardial SPECT. For validation on measuring left ventricular wall thickness with SPECT, fundamental studies were carried out with phantom models, and clinical studies were performed in 10 cases comparing the results from SPECT with those in echocardiography. To draw the WTM, left ventricular wall thickness was measured using the cut off method from SPECT images obtained at 5.6 mm intervals from the base and middle of left ventricle: short-axis image for the base and middle of left ventricle and vertical and horizontal long-axis images for the apical region. Wall thickness was defined from the number of pixel above the cut off level. Results of fundamental studies disclosed that it is impossible to evaluate the thickness of less than 10 mm by Tl-201 myocardial SPECT but possible to discriminate wall thickness of 10 mm, 15 mm, and 20 mm by Tl-201 myocardial SPECT. Echocardiographic results supported the validity of WTM, showing a good linear correlation (r = 0.96) between two methods on measuring wall thickness of left ventricle. We conclude that the WTM applied in this report may be useful for objective and quantitative estimation of myocardial hypertrophy. (author)

  9. Elastic stability of thick auxetic plates

    International Nuclear Information System (INIS)

    Lim, Teik-Cheng

    2014-01-01

    Auxetic materials and structures exhibit a negative Poisson’s ratio while thick plates encounter shear deformation, which is not accounted for in classical plate theory. This paper investigates the effect of a negative Poisson’s ratio on thick plates that are subjected to buckling loads, taking into consideration the shear deformation using Mindlin plate theory. Using a highly accurate shear correction factor that allows for the effect of Poisson’s ratio, the elastic stability of circular and square plates are evaluated in terms of dimensionless parameters, namely the Mindlin-to-Kirchhoff critical buckling load ratio and Mindlin critical buckling load factors. Results for thick square plates reveal that both parameters increase as the Poisson’s ratio becomes more negative. In the case of thick circular plates, the Mindlin-to-Kirchhoff critical buckling load ratios and the Mindlin critical buckling load factors increase and decrease, respectively, as the Poisson’s ratio becomes more negative. The results obtained herein show that thick auxetic plates behave as thin conventional plates, and therefore suggest that the classical plate theory can be used to evaluate the elastic stability of thick plates if the Poisson’s ratio of the plate material is sufficiently negative. The results also suggest that materials with highly negative Poisson’s ratios are recommended for square plates, but not circular plates, that are subjected to buckling loads. (paper)

  10. Rapid Measurement of Nanoparticle Thickness Profiles

    International Nuclear Information System (INIS)

    Katz-Boon, Hadas; Rossouw, Chris J.; Dwyer, Christian; Etheridge, Joanne

    2013-01-01

    A method to measure the thickness of a single-crystal nanoparticle in the direction parallel to the incident beam from annular dark field scanning transmission electron microscope (ADF-STEM) images is reported, providing a map of thickness versus position across the nanoparticle—a ‘thickness profile’ image. The method is rapid and hence suitable for surveying large numbers of nanoparticles. The method measures the intensity scattered to a characterised ADF detector and compares this to the incident beam intensity, to obtain a normalized ADF image. The normalised intensity is then converted to thickness via dynamical ADF image simulations. The method is accurate within 10% and the precision is dominated primarily by ‘shot noise’. Merits and limitations of this method are discussed. A method to calibrate the response function of the ADF detector without external equipment is also described, which is applicable to the entire range of gain and background settings. -- Highlights: ► A method is developed to convert ADF-STEM images to ‘thickness profile’ images. ► It is applicable in particles survey, facets determination and discrete tomography. ► A method to calibrate the response of the ADF detector is described. ► The response in analysed across a range of conditions. ► Dynamical ADF image simulations are presented, demonstrating intensity vs. thickness dependence.

  11. Predictor variables for marathon race time in recreational female runners.

    Science.gov (United States)

    Schmid, Wiebke; Knechtle, Beat; Knechtle, Patrizia; Barandun, Ursula; Rüst, Christoph Alexander; Rosemann, Thomas; Lepers, Romuald

    2012-06-01

    We intended to determine predictor variables of anthropometry and training for marathon race time in recreational female runners in order to predict marathon race time for future novice female runners. Anthropometric characteristics such as body mass, body height, body mass index, circumferences of limbs, thicknesses of skin-folds and body fat as well as training variables such as volume and speed in running training were related to marathon race time using bi- and multi-variate analysis in 29 female runners. The marathoners completed the marathon distance within 251 (26) min, running at a speed of 10.2 (1.1) km/h. Body mass (r=0.37), body mass index (r=0.46), the circumferences of thigh (r=0.51) and calf (r=0.41), the skin-fold thicknesses of front thigh (r=0.38) and of medial calf (r=0.40), the sum of eight skin-folds (r=0.44) and body fat percentage (r=0.41) were related to marathon race time. For the variables of training, maximal distance ran per week (r=- 0.38), number of running training sessions per week (r=- 0.46) and the speed of the training sessions (r= - 0.60) were related to marathon race time. In the multi-variate analysis, the circumference of calf (P=0.02) and the speed of the training sessions (P=0.0014) were related to marathon race time. Marathon race time might be partially (r(2)=0.50) predicted by the following equation: Race time (min)=184.4 + 5.0 x (circumference calf, cm) -11.9 x (speed in running during training, km/h) for recreational female marathoners. Variables of both anthropometry and training were related to marathon race time in recreational female marathoners and cannot be reduced to one single predictor variable. For practical applications, a low circumference of calf and a high running speed in training are associated with a fast marathon race time in recreational female runners.

  12. APPLIED ORIGAMI. Origami of thick panels.

    Science.gov (United States)

    Chen, Yan; Peng, Rui; You, Zhong

    2015-07-24

    Origami patterns, including the rigid origami patterns in which flat inflexible sheets are joined by creases, are primarily created for zero-thickness sheets. In order to apply them to fold structures such as roofs, solar panels, and space mirrors, for which thickness cannot be disregarded, various methods have been suggested. However, they generally involve adding materials to or offsetting panels away from the idealized sheet without altering the kinematic model used to simulate folding. We develop a comprehensive kinematic synthesis for rigid origami of thick panels that differs from the existing kinematic model but is capable of reproducing motions identical to that of zero-thickness origami. The approach, proven to be effective for typical origami, can be readily applied to fold real engineering structures. Copyright © 2015, American Association for the Advancement of Science.

  13. Translucency of dental ceramics with different thicknesses.

    Science.gov (United States)

    Wang, Fu; Takahashi, Hidekazu; Iwasaki, Naohiko

    2013-07-01

    The increased use of esthetic restorations requires an improved understanding of the translucent characteristics of ceramic materials. Ceramic translucency has been considered to be dependent on composition and thickness, but less information is available about the translucent characteristics of these materials, especially at different thicknesses. The purpose of this study was to investigate the relationship between translucency and the thickness of different dental ceramics. Six disk-shaped specimens of 8 glass ceramics (IPS e.max Press HO, MO, LT, HT, IPS e.max CAD LT, MO, AvanteZ Dentin, and Trans) and 5 specimens of 5 zirconia ceramics (Cercon Base, Zenotec Zr Bridge, Lava Standard, Lava Standard FS3, and Lava Plus High Translucency) were prepared following the manufacturers' instructions and ground to a predetermined thickness with a grinding machine. A spectrophotometer was used to measure the translucency parameters (TP) of the glass ceramics, which ranged from 2.0 to 0.6 mm, and of the zirconia ceramics, which ranged from 1.0 to 0.4 mm. The relationship between the thickness and TP of each material was evaluated using a regression analysis (α=.05). The TP values of the glass ceramics ranged from 2.2 to 25.3 and the zirconia ceramics from 5.5 to 15.1. There was an increase in the TP with a decrease in thickness, but the amount of change was material dependent. An exponential relationship with statistical significance (Pceramics and zirconia ceramics. The translucency of dental ceramics was significantly influenced by both material and thickness. The translucency of all materials increased exponentially as the thickness decreased. All of the zirconia ceramics evaluated in the present study showed some degree of translucency, which was less sensitive to thickness compared to that of the glass ceramics. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  14. Technical note: cortical thickness and density estimation from clinical CT using a prior thickness-density relationship

    NARCIS (Netherlands)

    Humbert, L.; Hazrati Marangalou, J.; Del Río Barquero, L.M.; van Lenthe, G.H.; van Rietbergen, B.

    2016-01-01

    Purpose: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical

  15. Thick-film analysis: literature search and bibliography

    International Nuclear Information System (INIS)

    Gehman, R.W.

    1981-09-01

    A literature search was conducted to support development of in-house diagnostic testing of thick film materials for hybrid microcircuits. A background literature review covered thick film formulation, processing, structure, and performance. Important material properties and tests were identified and several test procedures were obtained. Several tests were selected for thick film diagnosis at Bendix Kansas City. 126 references

  16. Rifting Thick Lithosphere - Canning Basin, Western Australia

    Science.gov (United States)

    Czarnota, Karol; White, Nicky

    2016-04-01

    The subsidence histories and architecture of most, but not all, rift basins are elegantly explained by extension of ~120 km thick lithosphere followed by thermal re-thickening of the lithospheric mantle to its pre-rift thickness. Although this well-established model underpins most basin analysis, it is unclear whether the model explains the subsidence of rift basins developed over substantially thick lithosphere (as imaged by seismic tomography beneath substantial portions of the continents). The Canning Basin of Western Australia is an example where a rift basin putatively overlies lithosphere ≥180 km thick, imaged using shear wave tomography. Subsidence modelling in this study shows that the entire subsidence history of the account for the observed subsidence, at standard crustal densities, the lithospheric mantle is required to be depleted in density by 50-70 kg m-3, which is in line with estimates derived from modelling rare-earth element concentrations of the ~20 Ma lamproites and global isostatic considerations. Together, these results suggest that thick lithosphere thinned to > 120 km is thermally stable and is not accompanied by post-rift thermal subsidence driven by thermal re-thickening of the lithospheric mantle. Our results show that variations in lithospheric thickness place a fundamental control on basin architecture. The discrepancy between estimates of lithospheric thickness derived from subsidence data for the western Canning Basin and those derived from shear wave tomography suggests that the latter technique currently is limited in its ability to resolve lithospheric thickness variations at horizontal half-wavelength scales of <300 km.

  17. Anthropometric changes in adolescents with anorexia nervosa in response to resistance training

    OpenAIRE

    Fernández del Valle, María; Larumbe Zabala, Eneko; Graell Berna, Montserrat; Pérez Ruiz, Margarita

    2015-01-01

    The follow-up of anthropometric percentiles such as triceps and mid-thigh skinfold thickness (TSF, MTSF), mid-upper arm and mid-thigh circumferences (MUAC, MTC), and arm and mid-thigh muscle areas (AMA, MTMA) after a resistance training might allow for detecting nutritional progress of fat and muscular tissue during the treatment of anorexia nervosa restricting (AN-R) type patients. A total of 44 AN-R patients were randomized for control (CG 13.0 ± 0.6 years) and intervention (IG 12.7 ± 0....

  18. Card controlled beta backscatter thickness measuring instrument

    International Nuclear Information System (INIS)

    Schlesinger, J.

    1978-01-01

    An improved beta backscatter instrument for the nondestructive measurement of the thickness of thin coatings on a substrate is described. Included therein is the utilization of a bank of memory stored data representative of isotope, substrate, coating material and thickness range characteristics in association with a control card having predetermined indicia thereon selectively representative of a particular isotope, substrate material, coating material and thickness range for conditioning electronic circuit means by memory stored data selected in accord with the predetermined indicia on a control card for converting backscattered beta particle counts into indicia of coating thickness

  19. Relationship of body build and development of pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, K

    1974-01-01

    Height, weight, Body Build Index (relative body weight), sub-scapular skinfold thickness, serum cholesterol level, hemoglobin concentration, and serum uric acid level immediately preceding detection of tuberculosis were compared between index and control cases on 145 pairs, by sex and age group (49 or under and 50 or over). Average height of index cases was greater than that of the control cases. Control cases were heavier than index cases for both sexes and age groups. Comparison of Body Build Index exhibited more distinct differences between the two groups, which were more remarkable in the older age group. Significantly thicker skinfold was demonstrated only among the female control cases. Serum cholesterol and uric acid level were significantly higher among the male control cases. No difference in hemoglobin concentration was observed between the index and control cases. Results not only support previous studies which had shown higher morbidity of tuberculosis among underweight persons, but also suggest that nutritional factors might be important in lowering the susceptibility to development of tuberculosis. (DLC)

  20. Debris thickness patterns on debris-covered glaciers

    Science.gov (United States)

    Anderson, Leif S.; Anderson, Robert S.

    2018-06-01

    Many debris-covered glaciers have broadly similar debris thickness patterns: surface debris thickens and tends to transition from convex- to concave-up-down glacier. We explain this pattern using theory (analytical and numerical models) paired with empirical observations. Down glacier debris thickening results from the conveyor-belt-like nature of the glacier surface in the ablation zone (debris can typically only be added but not removed) and from the inevitable decline in ice surface velocity toward the terminus. Down-glacier thickening of debris leads to the reduction of sub-debris melt and debris emergence toward the terminus. Convex-up debris thickness patterns occur near the up-glacier end of debris covers where debris emergence dominates (ablation controlled). Concave-up debris thickness patterns occur toward glacier termini where declining surface velocities dominate (velocity controlled). A convex-concave debris thickness profile inevitably results from the transition between ablation-control and velocity-control down-glacier. Debris thickness patterns deviating from this longitudinal shape are most likely caused by changes in hillslope debris supply through time. By establishing this expected debris thickness pattern, the effects of climate change on debris cover can be better identified.

  1. Storm-time slab thickness at low latitudes

    International Nuclear Information System (INIS)

    Chauhan, N.S.; Gurm, H.S.

    1981-01-01

    The ATS-6 data for a period of 1975-76 is used for the study of slab thickness during two moderate storms (Ksub(p) - ) around the crest of the anomaly, Ahmedabad and a very great (Ksub(p) + ) outside the equatorial anomaly region, Delhi. While at Ahmedabad, on the average, the slab thickness is found to be above the frequency. Comparison of slab thickness with foF2 and the equatorial magnetic record (for Ahmedabad only) shows that the foF2 changes alone cannot be held responsible for the slab thickness variation and thus entry of the plasma flux from the plasmasphere cannot be ruled out. The pressure variation effect of storm-time heating on the slab thickness at Ahmedabad is that even for Ksub(p)=8, the thermal expansion and the contraction effects are unable to explain complete quantitative and qualitative features of the observations

  2. The thickness of the interplanetary collisionless shock waves

    International Nuclear Information System (INIS)

    Pinter, S.

    1980-05-01

    The thicknesses of magnetic structures of the interplanetary shock waves related to the upstream solar wind plasma parameters are studied. From this study the following results have been obtained: the measured shock thickness increases for decreasing upstream proton number density and decreases for increasing proton flux energy. The shock thickness strongly depends on the ion plasma β, i.e. for higher values of the β the thickness decreases. (author)

  3. Effect of annealing, thickness ratio and bend angle on springback of AA6061-T6 with non-uniform thickness section

    Directory of Open Access Journals (Sweden)

    Adnan M.F.

    2017-01-01

    Full Text Available Non-uniform thickness section section is considered one of the most effective approaches to reduce automotive part weight. Reduction in term of mass and size result in less fuel consumption and greenhouse gases. Thickness is the most significant parameter to formability, therefore forming a section with non-uniform thickness becomes a great challenge. Improper process and incorrect decision may lead to severe defect and one of the main concerns is the springback. This study will focus on springback behaviour of non-uniform thickness AA6061 strip with complex profile using Taguchi Method. Profile projector (PC 3000 is used to measure the spring back and two-line technique is applied to measure angles (after loading between two lines. Three parameters (i.e. annealing temperature, thickness ratio and bend angle are studied, and results determine that the most significant parameter is bend angle, followed by thickness ratio, and then by the annealing temperature of the specimen during bending process.

  4. Skull thickness in patients with clefts

    DEFF Research Database (Denmark)

    Arntsen, T; Kjaer, I; Sonnesen, L

    2010-01-01

    The purpose was to analyze skull thickness in incomplete cleft lip (CL), cleft palate (CP), and combined cleft lip and palate (UCLP).......The purpose was to analyze skull thickness in incomplete cleft lip (CL), cleft palate (CP), and combined cleft lip and palate (UCLP)....

  5. Retinal sensitivity and choroidal thickness in high myopia.

    Science.gov (United States)

    Zaben, Ahmad; Zapata, Miguel Á; Garcia-Arumi, Jose

    2015-03-01

    To estimate the association between choroidal thickness in the macular area and retinal sensitivity in eyes with high myopia. This investigation was a transversal study of patients with high myopia, all of whom had their retinal sensitivity measured with macular integrity assessment microperimetry. The choroidal thicknesses in the macular area were then measured by optical coherence tomography, and statistical correlations between their functionality and the anatomical structuralism, as assessed by both types of measurements, were analyzed. Ninety-six eyes from 77 patients with high myopia were studied. The patients had a mean age ± standard deviation of 38.9 ± 13.2 years, with spherical equivalent values ranging from -6.00 diopter to -20.00 diopter (8.74 ± 2.73 diopter). The mean central choroidal thickness was 159.00 ± 50.57. The mean choroidal thickness was directly correlated with sensitivity (r = 0.306; P = 0.004) and visual acuity but indirectly correlated with the spherical equivalent values and patient age. The mean sensitivity was not significantly correlated with the macular foveal thickness (r = -0.174; P = 0.101) or with the overall macular thickness (r = 0.103; P = 0.334); furthermore, the mean sensitivity was significantly correlated with visual acuity (r = 0.431; P < 0.001) and the spherical equivalent values (r = -0.306; P = 0.003). Retinal sensitivity in highly myopic eyes is directly correlated with choroidal thickness and does not seem to be associated with retinal thickness. Thus, in patients with high myopia, accurate measurements of choroidal thickness may provide more accurate information about this pathologic condition because choroidal thickness correlates to a greater degree with the functional parameters, patient age, and spherical equivalent values.

  6. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  7. Body composition assessment in American Indian children.

    Science.gov (United States)

    Lohman, T G; Caballero, B; Himes, J H; Hunsberger, S; Reid, R; Stewart, D; Skipper, B

    1999-04-01

    Although the high prevalence of obesity in American Indian children was documented in several surveys that used body mass index (BMI, in kg/m2) as the measure, there is limited information on more direct measurements of body adiposity in this population. The present study evaluated body composition in 81 boys (aged 11.2+/-0.6 y) and 75 girls (aged 11.0+/-0.4 y) attending public schools in 6 American Indian communities: White Mountain Apache, Pima, and Tohono O'Odham in Arizona; Oglala Lakota and Sicangu Lakota in South Dakota; and Navajo in New Mexico and Arizona. These communities were participating in the feasibility phase of Pathways, a multicenter intervention for the primary prevention of obesity. Body composition was estimated by using a combination of skinfold thickness and bioelectrical impedance measurements, with a prediction equation validated previously in this same population. The mean BMI was 20.4+/-4.2 for boys and 21.1+/-5.0 for girls. The sum of the triceps plus subscapular skinfold thicknesses averaged 28.6+/-7.0 mm in boys and 34.0+/-8.0 mm in girls. Mean percentage body fat was 35.6+/-6.9 in boys and 38.8+/-8.5 in girls. The results from this study confirmed the high prevalence of excess body fatness in school-age American Indian children and permitted the development of procedures, training, and quality control for measurement of the main outcome variable in the full-scale Pathways study.

  8. Comparison of body composition and aerobic and anaerobic performance between competitive cyclists and triathletes

    Directory of Open Access Journals (Sweden)

    Vanderson Luis Moro

    2013-09-01

    Full Text Available The aim of this study was to compare anthropometric characteristics and aerobic and anaerobic fitness between competitive cyclists and triathletes. The sample consisted of 11cyclists and 12 triathletes with experience in competitions. The tests were performed on two different days, with an interval of 48 h between sessions. On the first day,the athletes were submitted to anthropometric assessment (body mass, height,and skinfold thickness and a maximal incremental test to determine maximal oxygen uptake, maximum power, maximum heart rate, maximum lactate, and the first (LL1 and second lactate threshold (LL2. The Wingate test was conducted on the second day to determine peak power, average power, and fatigue index. There were significant difference (p < 0.05, with medium effect size (0.80- 1.5, in mid-thigh skinfold thickness (15.2 ± 6.3 and 10.5 ± 4.8 mm, power at LL1 (195.0 ± 30.9 and 162.7 ± 28.3 W, power at LL2 (247.6 ± 25.0 and 219.7± 37.9 W, and fatigue index (47.2 ± 13.0 and 60.1 ± 16.4% between cyclists and triathletes, respectively. The other variables did not differ between groups. Anthropometric characteristics are similar in triathletes and cyclists. However, cyclists present higher power outputs at the lactate thresholds (LL1 and LL2 and lower fatigue indexes.

  9. Genetic parameters for chronic progressive lymphedema in Belgian Draught Horses.

    Science.gov (United States)

    De Keyser, K; Janssens, S; Peeters, L M; Foqué, N; Gasthuys, F; Oosterlinck, M; Buys, N

    2014-12-01

    Genetic parameters for chronic progressive lymphedema (CPL)-associated traits in Belgian Draught Horses were estimated, using a multitrait animal model. Clinical scores of CPL in the four limbs/horse (CPLclin ), skinfold thickness and hair samples (hair diameter) were studied. Due to CPLclin uncertainty in younger horses (progressive CPL character), a restricted data set (D_3+) was formed, excluding records from horses under 3 years from the complete data set (D_full). Age, gender, coat colour and limb hair pigmentation were included as fixed, permanent environment and date of recording as random effects. Higher CPLclin certainty (D_3+) increased heritability coefficients of, and genetic correlations between traits, with CPLclin heritabilities (SE) for the respective data sets: 0.11 (0.06) and 0.26 (0.05). A large proportion of the CPLclin variance was attributed to the permanent environmental effect in D_full, but less in D_3+. Date of recording explained a proportion of variance from 0.09 ± 0.03 to 0.61 ± 0.08. Additive genetic correlations between CPLclin and both skinfold thickness and hair diameter showed the latter two traits cannot be used as a direct diagnostic aid for CPL. Due to the relatively low heritability of CPLclin , selection should focus on estimated breeding values (from repeated clinical examinations) to reduce CPL occurrence in the Belgian Draught Horse. © 2014 Blackwell Verlag GmbH.

  10. 30 CFR 816.105 - Backfilling and grading: Thick overburden.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Backfilling and grading: Thick overburden. 816...-SURFACE MINING ACTIVITIES § 816.105 Backfilling and grading: Thick overburden. (a) Definition. Thick... surrounding terrain. (b) Performance standards. Where thick overburden occurs within the permit area, the...

  11. Radiographic detection of 100 A thickness variations in 1-μm-thick coatings applied to submillimeter-diameter laser fusion targets

    International Nuclear Information System (INIS)

    Stupin, D.M.

    1986-01-01

    We have developed x-ray radiography to measure thickness variations of coatings on laser fusion targets. Our technique is based on measuring the variation in x-ray transmission through the targets. The simplest targets are hollow glass microshells or microballoons 100 to 500 μm in diameter, that have several layers of metals or plastics, 1 to 100 μm thick. Our goal is to examine these opaque coatings for thickness variations as small as 1% or 0.1%, depending on the type of defect. Using contact radiography we have obtained the desired sensitivity for concentric and elliptical defects of 1%. This percentage corresponds to thickness variations as small as 100 A in a 1-μm-thick coating. For warts and dimples, the desired sensitivity is a function of the area of the defect, and we are developing a system to detect 0.1% thickness variations that cover an area 10 μm by 10 μm. We must use computer analysis of contact radiographs to measure 1% thickness variations in either concentricity or ellipticity. Because this analysis takes so long on our minicomputer, we preselect the radiographs by looking for defects at the 10% level on a video image analysis system

  12. Effectiveness of dispersants on thick oil slicks

    International Nuclear Information System (INIS)

    Ross, S.; Belore, R.

    1993-01-01

    Experiments were conducted to determine the relationship between dispersant effectiveness and oil slick thickness, and thereby determine the optimum time for applying dispersant onto spilled oil at sea. Tests were completed at a lab-scale level by varying the three parameters of oil type, dispersant application, and oil thickness. The tests were intended to be comparative only. The primary oils used were Alberta sweet mix blend and Hibernia B-27 crude. The dispersant, Corexit 9527, was applied either premixed with the oil, dropwise in one application, or dropwise in multiple applications to simulate a multi-hit aircraft operation. The apparatus used in the experiment was an oscillating hoop tank, with oil-containing rings used to obtain and maintain uniform slick thickness. The results indicate that the effectiveness potential of a chemical dispersant does not decrease as slick thickness increases. In fact, results of the tests involving Hibernia oil suggest that oils that tend to herd easily would be treated more effectively if dispersant were applied when the oil was relatively thick (1 mm or greater) to avoid herding problems. The oil slicks premixed with dispersant did not disperse well in the thick oil tests, not because of dispersant-oil interaction problems but because of reduced mixing energy. 6 refs., 4 figs., 1 tab

  13. TOSGAGETM-8000A series X-ray thickness gauge

    International Nuclear Information System (INIS)

    Obara, Satoshi

    2009-01-01

    X-ray thickness gauges are widely used for online measurement of the thickness of plates in a steel roiling line. As the thickness of the steel has a direct effect on the yield rate of the rolling line, thickness gauge measurement data are necessary for accuracy and reliability. In recent years, there have also been increasing requirements for rapid delivery, flexible interface specifications, and low cost. To meet these market requirements. Toshiba has developed the TOSGAGE TM -8000A series X-ray thickness gauge, which is the first release of a new series of measuring instruments for rolling applications with a new interface and employing an industrial computer for data processing. (author)

  14. Applications of precision ultrasonic thickness gauging

    International Nuclear Information System (INIS)

    Fowler, K.A.; Elfbaum, G.M.; Husarek, V.; Castel, J.G.

    1976-01-01

    Pulse-echo ultrasonic thickness gauging is now recognized as an accurate method of measuring thickness of a product from one side when the velocity of ultrasound in the material is known. The advantages and present limitation of this gauging technique are presented, together with several applications of industrial interest [fr

  15. Spacer Thickness-Dependent Electron Transport Performance of Titanium Dioxide Thick Film for Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Reda E. El-Shater

    2015-01-01

    Full Text Available A titanium dioxide (P25 film was deposited by cast coating as conductive photoelectrode and subsequently immersed in dye solution (N719 to fabricate the photoanode of dye-sensitized solar cells (DSSCs. A plastic spacer was used as a separation and sealant layer between the photoanode and the counter electrode. The effect of the thickness of this spacer on the transfer of electrons in the liquid electrolyte of the DSSCs was studied by means of both IV curves and electrochemical impedance. Using a spacer thickness range of 20 μm to 50 μm, efficiency ranges from 3.73% to 7.22%. The highest efficiency of 7.22% was obtained with an optimal spacer thickness of 40 μm.

  16. Correlates of eggshell thickness | Okereke | Global Journal of Pure ...

    African Journals Online (AJOL)

    This study discussed the effects of age and genotype of birds and location of farm on eggshell thickness. The ultimate objective of the study is to determine the correlates of eggshell thickness which may be relevant to improve eggshell thickness. Secondary data on eggshell thickness collected from the Agricultural ...

  17. Eggshell thickness in mourning dove populations

    Science.gov (United States)

    Kreitzer, J.F.

    1971-01-01

    Eggs (n = 452) of the mourning dove (Zenaidura macroura) were collected from 9 states in 1969 and 11 states in 1970, and shell thickness was compared with that of eggs (n = 97) collected from 24 states during the years 1861 to 1935. Mean shell thickness did not differ significantly in the test groups.

  18. Eddy current technologies for thick metal structures

    International Nuclear Information System (INIS)

    Takagi, Toshiyuki; Endo, Hisashi

    2004-01-01

    One of approach of an eddy current testing (ECT) for thick metal structures is introduced. The detection limit of ECT is capable of enlarging thick more than 10 mm, which is ordinarily about 5 mm, by the design of probe. On the basis of results of numerical analysis, the defect detection in thick and shape is evaluated by the distribution of experimental ECT signals. The problems of ECT for thick metal structures and measures, approach to probe design, the specifications of probe, evaluation of experimental results and defect detection are described. By ECT fast simulator, good slit sharp is simulated in the case of 10 and 20 mm of EDM slit length and 5, 10 and 15 mm of slit height. (S.Y.)

  19. Surgical correction of cryptotia combined with an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap.

    Science.gov (United States)

    Yu, Xiaobo; Yang, Qinghua; Jiang, Haiyue; Pan, Bo; Zhao, Yanyong; Lin, Lin

    2017-11-01

    Cryptotia is a common congenital ear deformity in Asian populations. In cryptotia, a portion of the upper ear is hidden and fixed in a pocket of the skin of the mastoid. Here we describe our method for cryptotia correction by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. We developed a new method for correcting cryptotia by using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap. Following ear release, the full-thickness skin rotation flap is rotated into the defect, and the donor site is covered with an ultra-delicate split-thickness skin graft raised in continuity with the flap. All patients exhibited satisfactory release of cryptotia. No cases involved partial or total flap necrosis, and post-operative outcomes using this new technique for cryptotia correction have been more than satisfactory. Our method of using an ultra-delicate split-thickness skin graft in continuity with a full-thickness skin rotation flap to correct cryptotia is simple and reliable. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Localizing gravity on exotic thick 3-branes

    International Nuclear Information System (INIS)

    Castillo-Felisola, Oscar; Melfo, Alejandra; Pantoja, Nelson; Ramirez, Alba

    2004-01-01

    We consider localization of gravity on thick branes with a nontrivial structure. Double walls that generalize the thick Randall-Sundrum solution, and asymmetric walls that arise from a Z 2 symmetric scalar potential, are considered. We present a new asymmetric solution: a thick brane interpolating between two AdS 5 spacetimes with different cosmological constants, which can be derived from a 'fake supergravity' superpotential, and show that it is possible to confine gravity on such branes

  1. A database of worldwide glacier thickness observations

    DEFF Research Database (Denmark)

    Gärtner-Roer, I.; Naegeli, K.; Huss, M.

    2014-01-01

    One of the grand challenges in glacier research is to assess the total ice volume and its global distribution. Over the past few decades the compilation of a world glacier inventory has been well-advanced both in institutional set-up and in spatial coverage. The inventory is restricted to glacier...... the different estimation approaches. This initial database of glacier and ice caps thickness will hopefully be further enlarged and intensively used for a better understanding of the global glacier ice volume and its distribution....... surface observations. However, although thickness has been observed on many glaciers and ice caps around the globe, it has not yet been published in the shape of a readily available database. Here, we present a standardized database of glacier thickness observations compiled by an extensive literature...... review and from airborne data extracted from NASA's Operation IceBridge. This database contains ice thickness observations from roughly 1100 glaciers and ice caps including 550 glacier-wide estimates and 750,000 point observations. A comparison of these observational ice thicknesses with results from...

  2. Minimum thickness blanket-shield for fusion reactors

    International Nuclear Information System (INIS)

    Karni, Y.; Greenspan, E.

    1989-01-01

    A lower bound on the minimum thickness fusion reactor blankets can be designed to have, if they are to breed 1.267 tritons per fusion neutron, is identified by performing a systematic nucleonic optimization of over a dozen different blanket concepts which use either Be, Li 17 Pb 83 , W or Zr for neutron multiplication. It is found that Be offers minimum thickness blankets; that the blanket and shield (B/S) thickness of Li 17 Pb 83 based blankets which are supplemented by Li 2 O and/or TiH 2 are comparable to the thickness of Be based B/S; that of the Be based blankets, the aqueous self-cooled one offers one of the most compact B/S; and that a number of blanket concepts might enable the design of B/S which is approximately 12 cm and 39 cm thinner than the B/S thickness of, respectively, conventional self-cooled Li 17 Pb 83 and Li blankets. Aqueous self-cooled tungsten blankets could be useful for experimental fusion devices provided they are designed to be heterogeneous. (orig.)

  3. Determination of the coating base thickness with beta backscattering gauges

    International Nuclear Information System (INIS)

    Krejndlin, I.I.; Novikov, V.S.; Pravikov, A.A.

    1976-01-01

    In using beta thickness meters for coating examination, it is necessary that the substrate thickness be greater or equal to the saturation thickness for which one can neglect a systematic error caused by substrate thickness variation. A formula is derived and nomograms are presented for the determination of the substrate saturation thickness with the account of factors affecting the results of coating thickness measurement. The results of saturation thickness calculation are tabulated for a number of substrate materials with using different β-sources ( 147 Pm, 85 Kr, 90 Sr+ 90 Y)

  4. Thick melanoma in Tuscany.

    Science.gov (United States)

    Chiarugi, Alessandra; Nardini, Paolo; Borgognoni, Lorenzo; Brandani, Paola; Gerlini, Gianni; Rubegni, Pietro; Lamberti, Arianna; Salvini, Camilla; Lo Scocco, Giovanni; Cecchi, Roberto; Sirna, Riccardo; Lorenzi, Stefano; Gattai, Riccardo; Battistini, Silvio; Crocetti, Emanuele

    2017-03-14

    The epidemiologic trends of cutaneous melanoma are similar in several countries with a Western-type life style, where there is a progressive increasing incidence and a low but not decreasing mor- tality, or somewhere an increase too, especially in the older age groups. Also in Tuscany there is a steady rise in incidence with prevalence of in situ and invasive thin melanomas, with also an increase of thick melanomas. It is necessary to reduce the frequency of thick melanomas to reduce specific mortality. The objective of the current survey has been to compare, in the Tuscany population, by a case- case study, thin and thick melanoma cases, trying to find out those personal and tumour characteristics which may help to customize preventive interventions. RESULTS The results confirmed the age and the lower edu- cation level are associated with a later detection. The habit to perform skin self-examination is resulted protec- tive forward thick melanoma and also the diagnosis by a doctor. The elements emerging from the survey allow to hypothesize a group of subjects resulting at higher risk for a late diagnosis, aged over 50 and carrier of a fewer constitutional and environmental risk factors: few total and few atypical nevi, and lower sun exposure and burning. It is assumable that a part of people did not be reached from messages of prevention because does not recognize oneself in the categories of people at risk for skin cancers described in educational cam- paigns. If we want to obtain better results on diagnosis of skin melanoma we have to think a new strategy. At least to think over the educational messages discriminating people more at risk of incidence of melanoma from people more at risk to die from melanoma, and to renewed active involvement of the Gen- eral Practitioners .

  5. Interferometric measurement of film thickness during bubble blowing

    Science.gov (United States)

    Wang, Z.; Mandracchia, B.; Ferraro, V.; Tammaro, D.; Di Maio, E.; Maffettone, P. L.; Ferraro, P.

    2017-06-01

    In this paper, we propose digital holography in transmission configuration as an effective method to measure the time-dependent thickness of polymeric films during bubble blowing. We designed a complete set of experiments to measure bubble thickness, including the evaluation of the refractive index of the polymer solution. We report the measurement of thickness distribution along the film during the bubble formation process until the bubble`s rupture. Based on those data, the variation range and variation trend of bubble film thickness are clearly measured during the process of expansion to fracture is indicated.

  6. Splitting diffraction peak in different thickness LL-interferometer and determination of thickness of damaged layer induced by electron irradiation of plates

    International Nuclear Information System (INIS)

    Truni, K.G.; Sedrakyan, A.G.; Papoyan, A.A.; Bezirganyan, P.A.

    1988-01-01

    Amplitude of twice reflected beam is calculated analytically, oscillatory dependence of peak intensity in the centre of diffraction image on the small variations in thickness is shown. The expression, clearly binding the splitting value of diffraction peak with variation in thickness of the interferometer plates, is received. The effect of variation in thickness on the splitting value of focal line is studied experimentally in case of irradiation of the equal-arm Π-shaped interferometer blocks by fast electron flow, thickness of the originated damaged layers are determined

  7. Process simulations for manufacturing of thick composites

    Science.gov (United States)

    Kempner, Evan A.

    The availability of manufacturing simulations for composites can significantly reduce the costs associated with process development. Simulations provide a tool for evaluating the effect of processing conditions on the quality of parts produced without requiring numerous experiments. This is especially significant in parts that have troublesome features such as large thickness. The development of simulations for thick walled composites has been approached by examining the mechanics of resin flow and fiber deformation during processing, applying these evaluations to develop simulations, and evaluating the simulation with experimental results. A unified analysis is developed to describe the three-dimensional resin flow and fiber preform deformation during processing regardless of the manufacturing process used. It is shown how the generic governing evaluations in the unified analysis can be applied to autoclave molding, compression molding, pultrusion, filament winding, and resin transfer molding. A comparison is provided with earlier models derived individually for these processes. The evaluations described for autoclave curing were used to produce a one-dimensional cure simulation for autoclave curing of thick composites. The simulation consists of an analysis for heat transfer and resin flow in the composite as well as bleeder plies used to absorb resin removed from the part. Experiments were performed in a hot press to approximate curing in an autoclave. Graphite/epoxy laminates of 3 cm and 5 cm thickness were cured while monitoring temperatures at several points inside the laminate and thickness. The simulation predicted temperatures fairly closely, but difficulties were encountered in correlation of thickness results. This simulation was also used to study the effects of prepreg aging on processing of thick composites. An investigation was also performed on filament winding with prepreg tow. Cylinders were wound of approximately 12 mm thickness with pressure

  8. Bladder wall thickness mapping for magnetic resonance cystography

    International Nuclear Information System (INIS)

    Zhao Yang; Liang Zhengrong; Zhu Hongbin; Han Hao; Yan Zengmin; Duan Chaijie; Lu Hongbing; Gu Xianfeng

    2013-01-01

    Clinical studies have shown evidence that the bladder wall thickness is an effective biomarker for bladder abnormalities. Clinical optical cystoscopy, the current gold standard, cannot show the wall thickness. The use of ultrasound by experts may generate some local thickness information, but the information is limited in field-of-view and is user dependent. Recent advances in magnetic resonance (MR) imaging technologies lead MR-based virtual cystoscopy or MR cystography toward a potential alternative to map the wall thickness for the entire bladder. From a high-resolution structural MR volumetric image of the abdomen, a reasonable segmentation of the inner and outer borders of the bladder wall can be achievable. Starting from here, this paper reviews the limitation of a previous distance field-based approach of measuring the thickness between the two borders and then provides a solution to overcome the limitation by an electric field-based strategy. In addition, this paper further investigates a surface-fitting strategy to minimize the discretization errors on the voxel-like borders and facilitate the thickness mapping on the three-dimensional patient-specific bladder model. The presented thickness calculation and mapping were tested on both phantom and human subject datasets. The results are preliminary but very promising with a noticeable improvement over the previous distance field-based approach. (paper)

  9. Influence of processing parameters on PZT thick films

    International Nuclear Information System (INIS)

    Huang, Oliver; Bandyopadhyay, Amit; Bose, Susmita

    2005-01-01

    We have studied influence of processing parameters on the microstructure and ferroelectric properties of lead zirconate titanate (PZT)-based thick films in the range of 5-25 μm. PZT and 2% La-doped PZT thick films were processed using a modified sol-gel process. In this process, PZT- and La-doped PZT powders were first prepared via sol-gel. These powders were calcined and then used with respective sols to form a slurry. Slurry composition was optimized to spin-coat thick films on platinized Si substrate (Si/SiO 2 /Ti/Pt). Spinning rate, acceleration and slurry deposition techniques were optimized to form thick films with uniform thickness and without any cracking. Increasing solids loading was found to enhance the surface smoothness of the film and decrease porosity. Films were tested for their electrical properties and ferroelectric fatigue response. The maximum polarization obtained was 40 μC/cm 2 at 250 kV/cm for PZT thick film and 30 μC/cm 2 at 450 kV/cm for La-doped PZT thick film. After 10 9 cycles of fatiguing at 35 kHz, La-doped PZT showed better resistance for ferroelectric fatigue compared with un-doped PZT films

  10. Loess Thickness Variations Across the Loess Plateau of China

    Science.gov (United States)

    Zhu, Yuanjun; Jia, Xiaoxu; Shao, Mingan

    2018-01-01

    The soil thickness is very important for investigating and modeling soil-water processes, especially on the Loess Plateau of China with its deep loess deposit and limited water resources. A digital elevation map (DEM) of the Loess Plateau and neighborhood analysis in ArcGIS software were used to generate a map of loess thickness, which was then validated by 162 observations across the plateau. The generated loess thickness map has a high resolution of 100 m × 100 m. The map indicates that loess is thick in the central part of the plateau and becomes gradually shallower in the southeast and northwest directions. The areas near mountains and river basins have the shallowest loess deposit. The mean loess thickness is the deepest in the zones with 400-600-mm precipitation and decreases gradually as precipitation varies beyond this range. Our validation indicates that the map just slightly overestimates loess thickness and is reliable. The loess thickness is mostly between 0 and 350 m in the Loess Plateau region. The calculated mean loess thickness is 105.7 m, with the calibrated value being 92.2 m over the plateau exclusive of the mountain areas. Our findings provide very basic data of loess thickness and demonstrate great progress in mapping the loess thickness distribution for the plateau, which are valuable for a better study of soil-water processes and for more accurate estimations of soil water, carbon, and solute reservoirs in the Loess Plateau of China.

  11. Smoluchowski coagulation models of sea ice thickness distribution dynamics

    Science.gov (United States)

    Godlovitch, D.; Illner, R.; Monahan, A.

    2011-12-01

    Sea ice thickness distributions display a ubiquitous exponential decrease with thickness. This tail characterizes the range of ice thickness produced by mechanical redistribution of ice through the process of ridging, rafting, and shearing. We investigate how well the thickness distribution can be simulated by representing mechanical redistribution as a generalized stacking process. Such processes are naturally described by a well-studied class of models known as Smoluchowski Coagulation Models (SCMs), which describe the dynamics of a population of fixed-mass "particles" which combine in pairs to form a "particle" with the combined mass of the constituent pair at a rate which depends on the mass of the interacting particles. Like observed sea ice thickness distributions, the mass distribution of the populations generated by SCMs has an exponential or quasi-exponential form. We use SCMs to model sea ice, identifying mass-increasing particle combinations with thickness-increasing ice redistribution processes. Our model couples an SCM component with a thermodynamic component and generates qualitatively accurate thickness distributions with a variety of rate kernels. Our results suggest that the exponential tail of the sea ice thickness distribution arises from the nature of the ridging process, rather than specific physical properties of sea ice or the spatial arrangement of floes, and that the relative strengths of the dynamic and thermodynamic processes are key in accurately simulating the rate at which the sea ice thickness tail drops off with thickness.

  12. The association between higher maternal pre-pregnancy body mass index and increased birth weight, adiposity and inflammation in the newborn.

    Science.gov (United States)

    McCloskey, K; Ponsonby, A-L; Collier, F; Allen, K; Tang, M L K; Carlin, J B; Saffery, R; Skilton, M R; Cheung, M; Ranganathan, S; Dwyer, T; Burgner, D; Vuillermin, P

    2018-01-01

    Excess adiposity and adiposity-related inflammation are known risk factors for cardiovascular disease in adults; however, little is known regarding the determinants of adiposity-related inflammation at birth. The aim of this study was to investigate the association between maternal pre-pregnancy BMI and newborn adiposity and inflammation. Paired maternal (28-week gestation) and infant (umbilical cord) blood samples were collected from a population-derived birth cohort (Barwon Infant Study, n = 1074). Data on maternal comorbidities and infant birth anthropomorphic measures were compiled, and infant aortic intima-media thickness was measured by trans-abdominal ultrasound. In a selected subgroup of term infants (n = 161), matched maternal and cord lipids, high-sensitivity C-reactive protein (hsCRP) and maternal soluble CD14 were measured. Analysis was completed by using pairwise correlation and linear regression. Because of their non-normal distribution, pathology blood measures were log transformed prior to analysis. Maternal pre-pregnancy BMI was positively associated with increased birth weight (mean difference 17.8 g per kg m -2 , 95% CI 6.6 to 28.9; p = 0.002), newborn mean skin-fold thickness (mean difference 0.1 mm per kg m -2 , 95% CI 0.0 to 0.1; p pregnancy BMI, 95% CI 0.6 to 7.7%, p = 0.02), but not cord blood soluble CD14. Inclusion of maternal hsCRP as a covariate attenuated the associations between pre-pregnancy BMI and both newborn skin-fold thickness and cord blood hsCRP. Higher maternal pre-pregnancy BMI is associated with increased newborn adiposity and inflammation. These associations may be partially mediated by maternal inflammation during pregnancy. © 2016 World Obesity Federation.

  13. Current Efavirenz (EFV or ritonavir-boosted lopinavir (LPV/r use correlates with elevate markers of atherosclerosis in HIV-infected subjects in Addis Ababa, Ethiopia.

    Directory of Open Access Journals (Sweden)

    Rudolph L Gleason

    Full Text Available HIV patients on antiretroviral therapy have shown elevated incidence of dyslipidemia, lipodystrophy, and cardiovascular disease (CVD. Most studies, however, focus on cohorts from developed countries, with less data available for these co-morbidities in Ethiopia and sub-Saharan Africa.Adult HIV-negative (n = 36, treatment naïve (n = 51, efavirenz (EFV-treated (n = 91, nevirapine (NVP-treated (n = 95, or ritonavir-boosted lopinavir (LPV/r-treated (n=44 subjects were recruited from Black Lion Hospital in Addis Ababa, Ethiopia. Aortic pressure, augmentation pressure, and pulse wave velocity (PWV were measured via applanation tonometry and carotid intima-media thickness (cIMT and carotid arterial stiffness, and brachial artery flow-mediated dilation (FMD were measured via non-invasive ultrasound. Body mass index, waist-to-hip circumference ratio (WHR, skinfold thickness, and self-reported fat redistribution were used to quantify lipodystrophy. CD4+ cell count, plasma HIV RNA levels, fasting glucose, total-, HDL-, and LDL-cholesterol, triglycerides, hsCRP, sVCAM-1, sICAM-1, leptin and complete blood count were measured.PWV and normalized cIMT were elevate and FMD impaired in EFV- and LPV/r-treated subjects compared to NVP-treated subjects; normalized cIMT was also elevated and FMD impaired in the EFV- and LPV/r-treated subjects compared to treatment-naïve subjects. cIMT was not statistically different across groups. Treated subjects exhibited elevated markers of dyslipidemia, inflammation, and lipodystrophy. PWV was associated with age, current EFV and LPV/r used, heart rate, blood pressure, triglycerides, LDL, and hsCRP, FMD with age, HIV duration, WHR, and glucose, and cIMT with age, current EFV use, skinfold thickness, and blood pressure.Current EFV- or LPV/r-treatment, but not NVP-treatment, correlated with elevated markers of atherosclerosis, which may involve mechanisms distinct from traditional risk factors.

  14. Cortical thickness patterns as state biomarker of anorexia nervosa.

    Science.gov (United States)

    Lavagnino, Luca; Mwangi, Benson; Cao, Bo; Shott, Megan E; Soares, Jair C; Frank, Guido K W

    2018-03-01

    Only few studies have investigated cortical thickness in anorexia nervosa (AN), and it is unclear whether patterns of altered cortical thickness can be identified as biomarkers for AN. Cortical thickness was measured in 19 adult women with restricting-type AN, 24 individuals recovered from restricting-type AN (REC-AN) and 24 healthy controls. Those individuals with current or recovered from AN had previously shown altered regional cortical volumes across orbitofrontal cortex and insula. A linear relevance vector machine-learning algorithm estimated patterns of regional thickness across 24 subdivisions of those regions. Region-based analysis showed higher cortical thickness in AN and REC-AN, compared to controls, in the right medial orbital (olfactory) sulcus, and greater cortical thickness for short insular gyri in REC-AN versus controls bilaterally. The machine-learning algorithm identified a pattern of relatively higher right orbital, right insular and left middle frontal cortical thickness, but lower left orbital, right middle and inferior frontal, and bilateral superior frontal cortical thickness specific to AN versus controls (74% specificity and 74% sensitivity, χ 2 p < .004); predicted probabilities differed significantly between AN and controls (p < .023). No pattern significantly distinguished the REC-AN group from controls. Higher cortical thickness in medial orbitofrontal cortex and insula probably contributes to higher gray matter volume in AN in those regions. The machine-learning algorithm identified a mixed pattern of mostly higher orbital and insular, but relatively lower superior frontal cortical thickness in individuals with current AN. These novel results suggest that regional cortical thickness patterns could be state markers for AN. © 2018 Wiley Periodicals, Inc.

  15. Thick Filament Protein Network, Functions, and Disease Association.

    Science.gov (United States)

    Wang, Li; Geist, Janelle; Grogan, Alyssa; Hu, Li-Yen R; Kontrogianni-Konstantopoulos, Aikaterini

    2018-03-13

    Sarcomeres consist of highly ordered arrays of thick myosin and thin actin filaments along with accessory proteins. Thick filaments occupy the center of sarcomeres where they partially overlap with thin filaments. The sliding of thick filaments past thin filaments is a highly regulated process that occurs in an ATP-dependent manner driving muscle contraction. In addition to myosin that makes up the backbone of the thick filament, four other proteins which are intimately bound to the thick filament, myosin binding protein-C, titin, myomesin, and obscurin play important structural and regulatory roles. Consistent with this, mutations in the respective genes have been associated with idiopathic and congenital forms of skeletal and cardiac myopathies. In this review, we aim to summarize our current knowledge on the molecular structure, subcellular localization, interacting partners, function, modulation via posttranslational modifications, and disease involvement of these five major proteins that comprise the thick filament of striated muscle cells. © 2018 American Physiological Society. Compr Physiol 8:631-709, 2018. Copyright © 2018 American Physiological Society. All rights reserved.

  16. Coating thickness measurement

    International Nuclear Information System (INIS)

    1976-12-01

    The standard specifies measurements of the coating thickness, which make use of beta backscattering and/or x-ray fluorescence. For commonly used combinations of coating material and base material the appropriate measuring ranges and radionuclides to be used are given for continuous as well as for discontinuous measurements

  17. Brief communication: Enamel thickness and durophagy in mangabeys revisited.

    Science.gov (United States)

    McGraw, W Scott; Pampush, James D; Daegling, David J

    2012-02-01

    The documentation of enamel thickness variation across primates is important because enamel thickness has both taxonomic and functional relevance. The Old World monkeys commonly referred to as mangabeys have figured prominently in investigations of feeding ecology and enamel thickness. In this article, we report enamel thickness values for four mangabey taxa (Cercocebus atys, Cercocebus torquatus, Lophocebus aterrimus, and Lophocebus albigena), offer revised interpretation of the significance of thick enamel in papionin evolution, and place our new data in a broader comparative framework. Our data indicate that all mangabeys have thick enamel and that the values obtained for Cercocebus and Lophocebus equal or exceed those published for most extant non-human primates. In addition, new field data combined with a current reading of the dietary literature indicate that hard foods make up a portion of the diet of every mangabey species sampled to date. Clarification on the relationship between diet and enamel thickness among mangabeys is important not only because of recognition that mangabeys are not a natural group but also because of recent arguments that explain thick enamel as an evolved response to the seasonal consumption of hard foods. Copyright © 2011 Wiley Periodicals, Inc.

  18. Self-heating forecasting for thick laminate specimens in fatigue

    Science.gov (United States)

    Lahuerta, F.; Westphal, T.; Nijssen, R. P. L.

    2014-12-01

    Thick laminate sections can be found from the tip to the root in most common wind turbine blade designs. Obtaining accurate and reliable design data for thick laminates is subject of investigations, which include experiments on thick laminate coupons. Due to the poor thermal conductivity properties of composites and the material self-heating that occurs during the fatigue loading, high temperature gradients may appear through the laminate thickness. In the case of thick laminates in high load regimes, the core temperature might influence the mechanical properties, leading to premature failures. In the present work a method to forecast the self-heating of thick laminates in fatigue loading is presented. The mechanical loading is related with the laminate self-heating, via the cyclic strain energy and the energy loss ratio. Based on this internal volumetric heat load a thermal model is built and solved to obtain the temperature distribution in the transient state. Based on experimental measurements of the energy loss factor for 10mm thick coupons, the method is described and the resulting predictions are compared with experimental surface temperature measurements on 10 and 30mm UD thick laminate specimens.

  19. Spin-wave wavelength down-conversion at thickness steps

    Science.gov (United States)

    Stigloher, Johannes; Taniguchi, Takuya; Madami, Marco; Decker, Martin; Körner, Helmut S.; Moriyama, Takahiro; Gubbiotti, Gianluca; Ono, Teruo; Back, Christian H.

    2018-05-01

    We report a systematic experimental study on the refraction and reflection of magnetostatic spin-waves at a thickness step between two Permalloy films of different thickness. The transmitted spin-waves for the transition from a thick film to a thin film have a higher wave vector compared to the incoming waves. Consequently, such systems may find use as passive wavelength transformers in magnonic networks. We investigate the spin-wave transmission behavior by studying the influence of the external magnetic field, incident angle, and thickness ratio of the films using time-resolved scanning Kerr microscopy and micro-focused Brillouin light scattering.

  20. Sampling supraglacial debris thickness using terrestrial photogrammetry

    Science.gov (United States)

    Nicholson, Lindsey; Mertes, Jordan

    2017-04-01

    The melt rate of debris-covered ice differs to that of clean ice primarily as a function of debris thickness. The spatial distribution of supraglacial debris thickness must therefore be known in order to understand how it is likely to impact glacier behaviour, and meltwater contribution to local hydrological resources and global sea level rise. However, practical means of determining debris cover thickness remain elusive. In this study we explore the utility of terrestrial photogrammetry to produce high resolution, scaled and texturized digital terrain models of debris cover exposures above ice cliffs as a means of quantifying and characterizing debris thickness. Two Nikon D5000 DSLRs with Tamron 100mm lenses were used to photograph a sample area of the Ngozumpa glacier in the Khumbu Himal of Nepal in April 2016. A Structure from Motion workflow using Agisoft Photoscan software was used to generate a surface models with <10cm resolution. A Trimble Geo7X differential GPS with Zephyr antenna, along with a local base station, was used to precisely measure marked ground control points to scale the photogrammetric surface model. Measurements of debris thickness along the exposed cliffline were made from this scaled model, assuming that the ice surface at the debris-ice boundary is horizontal, and these data are compared to 50 manual point measurements along the same clifftops. We conclude that sufficiently high resolution photogrammetry, with precise scaling information, provides a useful means to determine debris thickness at clifftop exposures. The resolution of the possible measurements depends on image resolution, the accuracy of the ground control points and the computational capacity to generate centimetre scale surface models. Application of such techniques to sufficiently high resolution imagery from UAV-borne cameras may offer a powerful means of determining debris thickness distribution patterns over debris covered glacier termini.

  1. three dimensional photoelastic investigations on thick rectangular

    African Journals Online (AJOL)

    user

    1983-09-01

    Sep 1, 1983 ... Thick rectangular plates are investigated by means of three-dimensional photoelasticity ... a thin plate theory and a higher order thick plate theory. 1. ..... number of fringes lest the accuracy of the results will be considerably.

  2. Portable abdomen radiography. Moving to thickness-based protocols

    International Nuclear Information System (INIS)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

    2018-01-01

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  3. Portable abdomen radiography. Moving to thickness-based protocols

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

    2018-02-15

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  4. On the book thickness of $k$-trees

    OpenAIRE

    Dujmović, Vida; Wood, David R.

    2009-01-01

    Graphs and Algorithms; International audience; Every k-tree has book thickness at most k + 1, and this bound is best possible for all k \\textgreater= 3. Vandenbussche et al. [SIAM J. Discrete Math., 2009] proved that every k-tree that has a smooth degree-3 tree decomposition with width k has book thickness at most k. We prove this result is best possible for k \\textgreater= 4, by constructing a k-tree with book thickness k + 1 that has a smooth degree-4 tree decomposition with width k. This s...

  5. Are galaxy discs optically thick?

    International Nuclear Information System (INIS)

    Disney, Michael; Davies, Jonathan; Phillipps, Steven

    1989-01-01

    We re-examine the classical optical evidence for the low optical depths traditionally assigned to spiral discs and argue that it is highly model-dependent and unconvincing. In particular, layered models with a physically thin but optically thick dust layer behave like optically thin discs. The opposite hypotheses, that such discs are optically thick is then examined in the light of modern evidence. We find it to be consistent with the near-infrared and IRAS observations, with the surface brightnesses, with the HI and CO column densities and with the Hα measurements. (author)

  6. Infrared sensing and the measurement of oil slick thickness

    International Nuclear Information System (INIS)

    Brown, H.M.; Baschuk, J.J.; Goodman, R.H.

    1998-01-01

    The issue of whether infrared images can be used to detect the thickness of a marine oil spill was discussed. Infrared images of oil spills on water show density variations because of variations in oil temperature and emissivity. These observations have been used to determine thickness variations in the oil. Experiments were conducted in a large wave basin using two typical crude oils in the thickness range of 1 mm to 10 mm. Infrared images of oil spills were recorded and simultaneous thickness measurements were made using an acoustic thickness gauge. The study showed that there is no relationship between infrared image pixel greyness and the thickness measured with an acoustic probe. It was not possible to determine the volume of a spill using infrared images. 2 refs., 1 tab., 4 figs

  7. Thickness measuring instrument for rubber cord calender production

    International Nuclear Information System (INIS)

    Ye Songfeng

    1988-01-01

    The thickness measuring gauge has been used to measure the rubber film thickness on the coating of textile cord at tire four cord calenders. Combined with micro-computer it completes the automatic control system and acheives automatic thickness measurement and adjustment. The fundamentals, construction, specifications, characteristic and application results are described. Prominent economic benefit has been gained for tire production

  8. Thick resist for MEMS processing

    Science.gov (United States)

    Brown, Joe; Hamel, Clifford

    2001-11-01

    The need for technical innovation is always present in today's economy. Microfabrication methods have evolved in support of the demand for smaller and faster integrated circuits with price performance improvements always in the scope of the manufacturing design engineer. The dispersion of processing technology spans well beyond IC fabrication today with batch fabrication and wafer scale processing lending advantages to MEMES applications from biotechnology to consumer electronics from oil exploration to aerospace. Today the demand for innovative processing techniques that enable technology is apparent where only a few years ago appeared too costly or not reliable. In high volume applications where yield and cost improvements are measured in fractions of a percent it is imperative to have process technologies that produce consistent results. Only a few years ago thick resist coatings were limited to thickness less than 20 microns. Factors such as uniformity, edge bead and multiple coatings made high volume production impossible. New developments in photoresist formulation combined with advanced coating equipment techniques that closely controls process parameters have enable thick photoresist coatings of 70 microns with acceptable uniformity and edge bead in one pass. Packaging of microelectronic and micromechanical devices is often a significant cost factor and a reliability issue for high volume low cost production. Technologies such as flip- chip assembly provide a solution for cost and reliability improvements over wire bond techniques. The processing for such technology demands dimensional control and presents a significant cost savings if it were compatible with mainstream technologies. Thick photoresist layers, with good sidewall control would allow wafer-bumping technologies to penetrate the barriers to yield and production where costs for technology are the overriding issue. Single pass processing is paramount to the manufacturability of packaging

  9. Geologic thickness data: Candidate repository horizons

    International Nuclear Information System (INIS)

    Cross, R.W.; Fairchild, K.R.

    1985-01-01

    This data package contains information on the thickness of the Umtanum, McCoy Canyon, Cohassett, and Rocky Coulee flows and their intraflow structures in 20 boreholes and 2 surface sections in the Pasco Basin. Thickness data are for total flow, flow top, entablature, and colonnade (or just flow top and dense interior in some cases). Summary figures which contain descriptions and footages are included

  10. A bend thickness sensitivity study of Candu feeder piping

    International Nuclear Information System (INIS)

    Li, M.; Aggarwal, M.L.; Meysner, A.; Micelotta, C.

    2005-01-01

    In CANDU reactors, feeder bends close to the connection at the fuel channel may be subjected to the highest Flow Accelerated Corrosion (FAC) and stresses. Feeder pipe stress analysis is crucial in the life extension of aging CANDU plants. Typical feeder pipes are interconnected by upper link plates and spacers. It is well known that the stresses at the bends are sensitive to the local bend thicknesses. It is also known from the authors' study (Li and et al, 2005) that feeder inter linkage effect is significant and cannot be ignored. The field measurement of feeder bend thickness is difficult and may be subjected to uncertainty in accuracy. Hence, it is desirable to know how the stress on a subject feeder could be affected by the bend thickness variation of the neighboring feeders. This effect cannot be evaluated by the traditional 'single' feeder model approach. In this paper, the 'row' and 'combined' models developed in the previous study (Li and et al, 2005), which include the feeder interactions, are used to investigate the sensitivity of bend thickness. A series of random thickness bounded by maximum and minimum measured values were applied to feeders in the model. The results show that an individual feeder is not sensitive to the bend thickness variation of the remaining feeders in the model, but depends primarily on its own bend thickness. The highest stress at a feeder always occurs when the feeder has the smallest possible bend thickness. A minimum acceptable bend thickness for individual feeders can be computed by an iterative computing process. The dependency of field thickness measurement and the amount of required analysis work can be greatly reduced. (authors)

  11. Biometric estimation of chest wall thickness of females

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1985-01-01

    Optimal use of whole-body counting data to estimate pulmonary deposition of many of the actinides is dependent upon accurate measurement of the thickness of the chest wall because of severe attenuation of low-energy x rays and photons associated with the decay of these radionuclides. An algorithm for estimation of female chest wall thicknesses, verified by real-time ultrasonic measurements, has been derived based on the correlation of measured chest wall thickness and other common biometric quantities. Use of this algorithm will reduce the error generally associated with estimation of internal actinide deposition previously resulting from assuming an average chest wall thickness for all female subjects

  12. Thickness measurement by two-sided step-heating thermal imaging

    Science.gov (United States)

    Li, Xiaoli; Tao, Ning; Sun, J. G.; Zhang, Cunlin; Zhao, Yuejin

    2018-01-01

    Infrared thermal imaging is a promising nondestructive technique for thickness prediction. However, it is usually thought to be only appropriate for testing the thickness of thin objects or near-surface structures. In this study, we present a new two-sided step-heating thermal imaging method which employed a low-cost portable halogen lamp as the heating source and verified it with two stainless steel step wedges with thicknesses ranging from 5 mm to 24 mm. We first derived the one-dimensional step-heating thermography theory with the consideration of warm-up time of the lamp, and then applied the nonlinear regression method to fit the experimental data by the derived function to determine the thickness. After evaluating the reliability and accuracy of the experimental results, we concluded that this method is capable of testing thick objects. In addition, we provided the criterions for both the required data length and the applicable thickness range of the testing material. It is evident that this method will broaden the thermal imaging application for thickness measurement.

  13. A variable thickness window: Thermal and structural analyses

    International Nuclear Information System (INIS)

    Wang, Zhibi; Kuzay, T.M.

    1994-01-01

    In this paper, the finite difference formulations for variable thickness thermal analysis and variable thickness plane stress analysis are presented. In heat transfer analysis, radiation effects and temperature-dependent thermal conductivity are taken into account. While in thermal stress analysis, the thermal expansion coefficient is considered as temperature dependent. An application of the variable thickness window to an Advanced Photon Source beamline is presented

  14. Collimation of particle beams from thick accretion discs

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, M [N. Copernicus Astronomical Center, Warszawa (Poland); Wilson, D B [Cambridge Univ. (UK). Inst. of Astronomy

    1981-11-01

    The acceleration and collimation of particle beams in the funnel of thick accretion discs is studied in the approximation that the flow is optically thin. Such flows can be collimated to within approximately 0.1 radians by sufficiently thick discs. The flow cannot convert more than a small fraction of the disc's (super-Eddington) luminosity into the energy flow of a narrow beam without being optically thick.

  15. Soliton models for thick branes

    International Nuclear Information System (INIS)

    Peyravi, Marzieh; Riazi, Nematollah; Lobo, Francisco S.N.

    2016-01-01

    In this work, we present new soliton solutions for thick branes in 4+1 dimensions. In particular, we consider brane models based on the sine-Gordon (SG), φ 4 and φ 6 scalar fields, which have broken Z 2 symmetry in some cases and are responsible for supporting and stabilizing the thick branes. The origin of the symmetry breaking in these models resides in the fact that the modified scalar field potential may have non-degenerate vacua. These vacua determine the cosmological constant on both sides of the brane. We also study the geodesic equations along the fifth dimension, in order to explore the particle motion in the neighborhood of the brane. Furthermore, we examine the stability of the thick branes, by determining the sign of the w 2 term in the expansion of the potential for the resulting Schroedinger-like equation, where w is the five-dimensional coordinate. It turns out that the φ 4 brane is stable, while there are unstable modes for certain ranges of the model parameters in the SG and φ 6 branes. (orig.)

  16. The Thickness Dependence of Optical Constants of Ultrathin Iron Films

    International Nuclear Information System (INIS)

    Gao Shang; Lian Jie; Wang Xiao; Li Ping; Sun Xiao-Fen; Li Qing-Hao

    2013-01-01

    Ultrathin iron films with different thicknesses from 7.1 to 51.7 nm are deposited by magnetron sputtering and covered by tantalum layers protecting them from being oxidized. These ultrathin iron films are studied by spectroscopic ellipsometry and transmittance measurement. An extra tantalum film is deposited under the same sputtering conditions and its optical constants and film thickness are obtained by a combination of ellipsometry and transmission measurement. After introducing these obtained optical constants and film thickness into the tantalum-iron film, the optical constants and film thicknesses of ultrathin iron films with different thicknesses are obtained. The results show that combining ellipsometry and transmission measurement improves the uniqueness of the obtained film thickness. The optical constants of ultrathin iron films depend strongly on film thicknesses. There is a broad absorption peak at about 370 nm and it shifts to 410 nm with film thickness decreasing

  17. Thick film heater for sensor application

    International Nuclear Information System (INIS)

    Milewski, J; Borecki, M; Kalenik, J; Król, K

    2014-01-01

    A thick film microheater was elaborated. The microheater is intended for fast heating of small volume samples under measurement in optical based system. Thermal analysis of microheater was carried out using finite element method (FEM) for heat transfer calculation as a function of time and space. A nodal heat transfer function was calculated in classical form including all basics mechanisms of heat exchange – heat conduction, convection and radiation were considered. Work focuses on the influence of some construction parameters (ex. length, thermal conductivity of substrate, substrate thickness) on microheater performance. The results show that application of thin substrate of low thermal conductivity and low thickness for miroheater construction and resistor of optimum dimensions leads to significant power consumption decrease and increase of overall optical measurement system performance.

  18. The design and characteristics of QNT-type thickness gauge

    International Nuclear Information System (INIS)

    Li Furong; Liu Yisi

    1992-01-01

    The theoretical projection of QNT-Type radiation thickness gauge is given. The relations between sensitivity and radiation energy, the thickness resolution and the effect of scattering radiation have been discussed. The characteristics of this type of thickness gauge were described

  19. XRD measurement of mean thickness, thickness distribution and strain for illite and illite-smectite crystallites by the Bertaut-Warren-Averbach technique

    Science.gov (United States)

    Drits, Victor A.; Eberl, Dennis D.; Środoń, Jan

    1998-01-01

    A modified version of the Bertaut-Warren-Averbach (BWA) technique (Bertaut 1949, 1950; Warren and Averbach 1950) has been developed to measure coherent scattering domain (CSD) sizes and strains in minerals by analysis of X-ray diffraction (XRD) data. This method is used to measure CSD thickness distributions for calculated and experimental XRD patterns of illites and illite-smectites (I-S). The method almost exactly recovers CSD thickness distributions for calculated illite XRD patterns. Natural I-S samples contain swelling layers that lead to nonperiodic structures in the c* direction and to XRD peaks that are broadened and made asymmetric by mixed layering. Therefore, these peaks cannot be analyzed by the BWA method. These difficulties are overcome by K-saturation and heating prior to X-ray analysis in order to form 10-Å periodic structures. BWA analysis yields the thickness distribution of mixed-layer crystals (coherently diffracting stacks of fundamental illite particles). For most I-S samples, CSD thickness distributions can be approximated by lognormal functions. Mixed-layer crystal mean thickness and expandability then can be used to calculate fundamental illite particle mean thickness. Analyses of the dehydrated, K-saturated samples indicate that basal XRD reflections are broadened by symmetrical strain that may be related to local variations in smectite interlayers caused by dehydration, and that the standard deviation of the strain increases regularly with expandability. The 001 and 002 reflections are affected only slightly by this strain and therefore are suited for CSD thickness analysis. Mean mixed-layer crystal thicknesses for dehydrated I-S measured by the BWA method are very close to those measured by an integral peak width method.

  20. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  1. Ocean Sediment Thickness Contours

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean sediment thickness contours in 200 meter intervals for water depths ranging from 0 - 18,000 meters. These contours were derived from a global sediment...

  2. Wall thickness of major coronary arteries in Pakistani population

    International Nuclear Information System (INIS)

    Ullah, Q.W.; Qamar, K.; Butt, S.A.; Butt, S.A.

    2012-01-01

    To measure the wall thickness of major coronary arteries in Pakistani population, through micrometry. Study design: An observational study. Place and duration of study: Combined Military Hospital Rawalpindi, Khyber Medical College Peshawar and District Headquarter Hospital, Rawalpindi, in collaboration with Departments of Anatomy and Pathology, Army Medical College Rawalpindi. The duration of study was six months with effect from September 2009 to March 2010. Material and methods: After incising pericardium, 1 mm long segments of major coronary arteries i.e. right coronary artery (RCA), left anterior descending artery (LAD) and left circumflex artery (LCX) were taken 1cm distal to their origin, from adult male cadavers of up to 40 years age. After processing for paraffin embedding, 5 mu m thick sections were prepared, mounted on glass slides and subsequently stained with Hematoxylin and Eosin (H and E) for routine histological study. Verhoeff's elastic stain was used to make the elastic lamina more prominent. Wall thickness for each section was measured through micrometry, circumferentially at eight different places along the planes at 45 deg. to each other and then their mean taken as a reading for the respective artery. Results: The total wall thickness of major coronary arteries and of the individual tunicae was less in Pakistani population. The mean thickness of RCA was 0.61 +- 0.05 mm; LAD had mean thickness of 0.55 +- 0.06 mm whereas that of LCX was 0.66 +- 0.13 mm. The mean thickness of tunica intima of RCA was noted to be 0.230 +- 0.044 mm; tunica media measured 0.205 +- 0.031 mm whereas tunica adventitia was 0.172 +- 0.023 mm thick. The mean thickness of tunica intima of LAD measured 0.156 +- 0.032 mm; tunica media was observed to be 0.224 +- 0.026 mm thick whereas the tunica adventitia was 0.170 +- 0.032 mm thick. The mean thickness of tunica intima of LCX was observed to be 0.203 +- 0.059 mm; tunica media to be 0.282 +- 0.097 mm whereas that of tunica

  3. Model-based cartilage thickness measurement in the submillimeter range

    International Nuclear Information System (INIS)

    Streekstra, G. J.; Strackee, S. D.; Maas, M.; Wee, R. ter; Venema, H. W.

    2007-01-01

    Current methods of image-based thickness measurement in thin sheet structures utilize second derivative zero crossings to locate the layer boundaries. It is generally acknowledged that the nonzero width of the point spread function (PSF) limits the accuracy of this measurement procedure. We propose a model-based method that strongly reduces PSF-induced bias by incorporating the PSF into the thickness estimation method. We estimated the bias in thickness measurements in simulated thin sheet images as obtained from second derivative zero crossings. To gain insight into the range of sheet thickness where our method is expected to yield improved results, sheet thickness was varied between 0.15 and 1.2 mm with an assumed PSF as present in the high-resolution modes of current computed tomography (CT) scanners [full width at half maximum (FWHM) 0.5-0.8 mm]. Our model-based method was evaluated in practice by measuring layer thickness from CT images of a phantom mimicking two parallel cartilage layers in an arthrography procedure. CT arthrography images of cadaver wrists were also evaluated, and thickness estimates were compared to those obtained from high-resolution anatomical sections that served as a reference. The thickness estimates from the simulated images reveal that the method based on second derivative zero crossings shows considerable bias for layers in the submillimeter range. This bias is negligible for sheet thickness larger than 1 mm, where the size of the sheet is more than twice the FWHM of the PSF but can be as large as 0.2 mm for a 0.5 mm sheet. The results of the phantom experiments show that the bias is effectively reduced by our method. The deviations from the true thickness, due to random fluctuations induced by quantum noise in the CT images, are of the order of 3% for a standard wrist imaging protocol. In the wrist the submillimeter thickness estimates from the CT arthrography images correspond within 10% to those estimated from the anatomical

  4. Perceptions of Healthy-Looking and Sexy-Looking Brow Thickness.

    Science.gov (United States)

    Hwang, Kun; Kim, Hun

    2018-06-01

    This study aims to determine which brow thickness levels were considered ideal, healthy-looking, young-looking, and sexy-looking by Koreans.The 163 women and 38 men who visited a brow bar were asked to view illustrations of 4 brow thickness levels defined in terms of the percentage of the eye width at the lateral canthus: very thin (VTn-1/6) (16% of eye width), thin (Tn-1/5) (20%), medium (Med-1/4) (25%), and thick (Tk-1/3) (33%) and to choose which they thought were ideal, young-looking, healthy-looking, and sexy-looking.Med-1/4 (61.2%) was the brow thickness most often considered to be ideal, followed by Tk-1/3 (17.4%) and Tn-1/5 (15.9%). VTn-1/6 was the least preferred (5.5%). Med-1/4 was the most preferred ideal thickness among both sexes. Tk-1/3 (40.8%) was the thickness most often considered to be young-looking, followed by Med-1/4 (35.3%) and Tn-1/5 (18.4%). VTn-1/6 was the least preferred (5.5%). Tk-1/3 was the most preferred young-looking thickness among both sexes. Tk-1/3 (48.8%) was the thickness most often considered to be healthy-looking, followed by Med-1/4 (30.8%) and Tn-1/5 (11.9%). VTn-1/6 was the least preferred (8.5%). Tk-1/3 was the most preferred healthy-looking thickness by women (52.2%), whereas Med-1/4 was the most common choice among men (39.5%). Tn-1/5 (40.8%) was the thickness most often considered to be sexy-looking, followed by VTn-1/6 (25.9%) and Med-1/4 (21.4%). Tk-1/3 was the least preferred (11.9%). Tn-1/5 was the most preferred sexy-looking thickness among both sexes.The results may be used as guidelines for patient or customer preferences in facial rejuvenation operations, brow esthetics, or tattooing.

  5. Critical thickness of atomically ordered III-V alloys

    Energy Technology Data Exchange (ETDEWEB)

    France, R. M.; McMahon, W. E.; Guthrey, H. L. [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401 (United States)

    2015-10-12

    The critical thickness model is modified with a general boundary energy that describes the change in bulk energy as a dislocation regularly alters the atomic structure of an ordered material. The model is evaluated for dislocations gliding through CuPt-ordered GaInP and GaInAs, where the boundary energy is negative and the boundary is stable. With ordering present, the critical thickness is significantly lowered and remains finite as the mismatch strain approaches zero. The reduction in critical thickness is most significant when the order parameter is greatest and the amount of misfit energy is low. The modified model is experimentally validated for low-misfit GaInP epilayers with varying order parameters using in situ wafer curvature and ex situ cathodoluminescence. With strong ordering, relaxation begins at a lower thickness and occurs at a greater rate, which is consistent with a lower critical thickness and increased glide force. Thus, atomic ordering is an important consideration for the stability of lattice-mismatched devices.

  6. The Thickness of Amalgamations and Cartesian Product of Graphs

    Directory of Open Access Journals (Sweden)

    Yang Yan

    2017-08-01

    Full Text Available The thickness of a graph is the minimum number of planar spanning subgraphs into which the graph can be decomposed. It is a measurement of the closeness to the planarity of a graph, and it also has important applications to VLSI design, but it has been known for only few graphs. We obtain the thickness of vertex-amalgamation and bar-amalgamation of graphs, the lower and upper bounds for the thickness of edge-amalgamation and 2-vertex-amalgamation of graphs, respectively. We also study the thickness of Cartesian product of graphs, and by using operations on graphs, we derive the thickness of the Cartesian product Kn □ Pm for most values of m and n.

  7. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    Science.gov (United States)

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Trochanteric Soft Tissue Thickness and Hip Fracture in Older Men

    Science.gov (United States)

    Nielson, Carrie M.; Bouxsein, Mary L.; Freitas, Sinara S.; Ensrud, Kristine E.; Orwoll, Eric S.

    2009-01-01

    Background: Greater thickness of the tissue extending laterally from the greater trochanter has been associated with a lower risk of hip fracture in women. The effect of trochanteric soft tissue thickness on the risk of incident hip fracture has not been evaluated in men. Methods: We measured trochanteric soft tissue thickness by dual-energy x-ray absorptiometry for all incident hip fracture cases (n = 70) and 222 randomly selected noncases in older men (≥65 yr) enrolled in the Osteoporotic Fractures in Men (MrOS) Study. Differences in tissue thickness between cases and controls were examined. Changes in fall force and factor-of-risk (the ratio of force from a sideways fall to femoral bone strength) associated with tissue thickness were determined. The relative risk for incident hip fracture per sd decrease in tissue thickness was calculated. Results: Mean trochanteric soft tissue thickness did not differ significantly between cases and noncases (29.1 ± 11.9 vs 31.0 ± 11.5 mm; P = 0.2). Although increased tissue thickness reduced both the estimates of fall force and the factor-of-risk, tissue thickness was not associated with the risk of hip fracture (age- and bone mineral density-adjusted relative risk per sd decrease in tissue thickness = 0.90; 95% confidence interval, 0.70–1.16). Conclusions: In this study of elderly community-dwelling men, we found no significant association between trochanteric soft tissue thickness and incident hip fracture. Trochanteric soft tissue thickness in these men was less than previously reported in older women and may explain the difference between these results and those reported in women. PMID:19017753

  9. Mass thickness measurement of dual-sample by dual-energy X-rays

    International Nuclear Information System (INIS)

    Chen Mincong; Li Hongmei; Chen Ziyu; Shen Ji

    2008-01-01

    X-ray equivalent energy can be used to measure mass thicknesses of materials. Based on this, a method of mass thickness measurement of dual-sample was discussed. It was found that in the range of sample mass thickness under investigation, the equivalent mass attenuation coefficient of a component could be used to compute mass thicknesses of a dual-sample, with relative errors of less than 5%. Mass thickness measurement of a fish sample was performed, and the fish bone and flesh could be displayed separately and clearly by their own mass thicknesses. This indicates that the method is effective in mass thickness measurement of dual-sample of suitable thicknesses. (authors)

  10. Surgical Management of the Thick-Skinned Nose.

    Science.gov (United States)

    Davis, Richard E; Hrisomalos, Emily N

    2018-02-01

    When executed properly, open structure rhinoplasty can dramatically improve the consistency, durability, and quality of the cosmetic surgical outcome. Moreover, in expert hands, dramatic transformations in skeletal architecture can be accomplished with minimal risk and unparalleled control, all while preserving nasal airway function. While skeletal enhancements have become increasingly more controlled and precise, the outer skin-soft tissue envelope (SSTE) often presents a formidable obstacle to a satisfactory cosmetic result. In noses with unusually thick skin, excessive skin volume and characteristically hostile healing responses frequently combine to obscure or sometimes even negate cosmetic skeletal modifications and taint the surgical outcome. For this challenging patient subgroup, care must be taken to optimize the SSTE using a graduated treatment strategy directed at minimizing skin thickness and controlling unfavorable healing responses. When appropriate efforts are implemented to manage thick nasal skin, cosmetic outcomes are often substantially improved, sometimes even negating the ill-effects of thick skin altogether. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Interocular Symmetry in Macular Choroidal Thickness in Children

    Directory of Open Access Journals (Sweden)

    Christiane Al-Haddad

    2014-01-01

    Full Text Available Objective. To report interocular differences in choroidal thickness in children using spectral domain optical coherence tomography (SD-OCT and correlate findings with biometric data. Methods. This observational cross-sectional study included 91 (182 eyes healthy children aged 6 to 17 years with no ocular abnormality except refractive error. After a comprehensive eye exam and axial length measurement, high definition macular scans were performed using SD-OCT. Two observers manually measured the choroidal thickness at the foveal center and at 1500 µm nasally, temporally, inferiorly, and superiorly. Interocular differences were computed; correlations with age, gender, refractive error, and axial length were performed. Results. Mean age was 10.40 ± 3.17 years; mean axial length and refractive error values were similar between fellow eyes. There was excellent correlation between the two observers’ measurements. No significant interocular differences were observed at any location. There was only a trend for right eyes to have higher values in all thicknesses, except the superior thickness. Most of the choroidal thickness measurements correlated positively with spherical equivalent but not with axial length, age, or gender. Conclusion. Choroidal thickness measurements in children as performed using SD-OCT revealed a high level of interobserver agreement and consistent interocular symmetry. Values correlated positively with spherical equivalent refraction.

  12. Interocular symmetry in macular choroidal thickness in children.

    Science.gov (United States)

    Al-Haddad, Christiane; El Chaar, Lama; Antonios, Rafic; El-Dairi, Mays; Noureddin, Baha'

    2014-01-01

    Objective. To report interocular differences in choroidal thickness in children using spectral domain optical coherence tomography (SD-OCT) and correlate findings with biometric data. Methods. This observational cross-sectional study included 91 (182 eyes) healthy children aged 6 to 17 years with no ocular abnormality except refractive error. After a comprehensive eye exam and axial length measurement, high definition macular scans were performed using SD-OCT. Two observers manually measured the choroidal thickness at the foveal center and at 1500 µm nasally, temporally, inferiorly, and superiorly. Interocular differences were computed; correlations with age, gender, refractive error, and axial length were performed. Results. Mean age was 10.40 ± 3.17 years; mean axial length and refractive error values were similar between fellow eyes. There was excellent correlation between the two observers' measurements. No significant interocular differences were observed at any location. There was only a trend for right eyes to have higher values in all thicknesses, except the superior thickness. Most of the choroidal thickness measurements correlated positively with spherical equivalent but not with axial length, age, or gender. Conclusion. Choroidal thickness measurements in children as performed using SD-OCT revealed a high level of interobserver agreement and consistent interocular symmetry. Values correlated positively with spherical equivalent refraction.

  13. Automated Estimation of Melanocytic Skin Tumor Thickness by Ultrasonic Radiofrequency Data.

    Science.gov (United States)

    Andrekute, Kristina; Valiukeviciene, Skaidra; Raisutis, Renaldas; Linkeviciute, Gintare; Makstiene, Jurgita; Kliunkiene, Renata

    2016-05-01

    High-frequency (>20-MHz) ultrasound (US) is a noninvasive preoperative tool for assessment of melanocytic skin tumor thickness. Ultrasonic melanocytic skin tumor thickness estimation is not always easy and is related to the experience of the clinician. In this article, we present an automated thickness measurement method based on time-frequency analysis of US radiofrequency signals. The study was performed on 52 thin (≤1-mm) melanocytic skin tumors (46 melanocytic nevi and 6 melanomas). Radiofrequency signals were obtained with a single-element focused transducer (fundamental frequency, 22 MHz; bandwidth, 12-28 MHz). The radiofrequency data were analyzed in the time-frequency domain to make the tumor boundaries more noticeable. The thicknesses of the tumors were evaluated by 3 different metrics: histologically measured Breslow thickness, manually measured US thickness, and automatically measured US thickness. The results showed a higher correlation coefficient between the automatically measured US thickness and Breslow thickness (r= 0.83; Pmeasured US thickness (r = 0.68; P measurement algorithm was 96.55%, and the specificity was 78.26% compared with histologic measurement. The sensitivity of the manually measured US thickness was 75.86%, and the specificity was 73.91%. The efficient automated tumor thickness measurement method developed could be used as a tool for preoperative assessment of melanocytic skin tumor thickness. © 2016 by the American Institute of Ultrasound in Medicine.

  14. Undernutrition in children with profound intellectual and multiple disabilities (PIMD): its prevalence and influence on quality of life.

    Science.gov (United States)

    Holenweg-Gross, C; Newman, C J; Faouzi, M; Poirot-Hodgkinson, I; Bérard, C; Roulet-Perez, E

    2014-07-01

    To estimate the prevalence of undernutrition among children with profound intellectual and multiple disabilities (PIMD) and to explore its influence on quality of life. Seventy-two children with PIMD (47 male; 25 female; age range 2 to 15 years 4 months; mean age 8.6, SD 3.6) underwent an anthropometric assessment, including body weight, triceps skinfold thickness, segmental measures and recumbent length. Undernutrition was determined using tricipital skinfold percentile and z-scores of weight-for-height and height-for-age. The quality of life of each child was evaluated using the QUALIN questionnaire adapted for profoundly disabled children. Twenty-five children (34.7%) were undernourished and seven (9.7%) were obese. Among undernourished children only eight (32 %) were receiving food supplements and two (8%) had a gastrostomy, of which one was still on a refeeding programme. On multivariate analysis, undernutrition was one of the independent predictors of lower quality of life. Undernutrition remains a matter of concern in children with PIMD. There is a need to better train professionals in systematically assessing the nutritional status of profoundly disabled children in order to start nutritional management when necessary. © 2013 John Wiley & Sons Ltd.

  15. Body size, composition, and blood pressure of high-altitude Quechua from the Peruvian Central Andes (Huancavelica, 3,680 m).

    Science.gov (United States)

    Toselli, S; Tarazona-Santos, E; Pettener, D

    2001-01-01

    Although much information is available about the effects of high altitude on physiological characteristics, less is know about its effect on body composition. In the present study, anthropometric and body composition variables were investigated in a sample of 77 adult Quechua males from the Peruvian Central Andes (Huancavelica, 3,680 m). The subjects are shorter in relation to body weight than other ethnic groups, whereas body proportions are macrocormic (indicating a long trunk relative to the lower extremities), with intermediate values of the acromial-iliac index. All skinfold thicknesses are low (approximately 15th percentiles of NHANES reference values for the triceps and subscapular skinfolds), but tend to be higher than in the other Quechua populations. Similar results are obtained when percentage fat is estimated. Somatotypes are dominant in mesomorphy with very low ectomorphy. Comparison with a sample of high-altitude Kirghiz (3,200 m), previously studied with the same methods, shows higher values in the Peruvian sample for all variables related to adiposity. The presence of low adiposity in the Quechua population could be associated with stresses of the high-altitude environment. Mean values of blood pressure are very low and there is no correlation with age.

  16. Pre- and Postoperative Body Composition and Metabolic Characteristics in Patients with Acromegaly: A Prospective Study

    Science.gov (United States)

    Gao, Lu; Li, Hailong; Wang, Qiang; Wang, Zihao

    2018-01-01

    Objective To investigate the preoperative body composition, metabolic characteristics, and postoperative changes in patients with active acromegaly and analyze the effects of gender and age. Methods We included 36 patients with untreated acromegaly and 37 patients with nonfunctional pituitary adenomas. Adipose tissue (AT), the visceral fat index (VFI), sclerotin, protein, skeletal muscle, total body water (TBW), intracellular water (ICW), and extracellular water (ECW) were measured using bioelectrical impedance analysis (BIA). Total energy expenditure (TEE) and basal metabolism (BM) were measured with a cardiopulmonary and metabolic analyzer (CMA). Tricep skinfold thickness (TST), bicep circumference, waistline, hipline, and calf circumference were measured with a skinfold caliper and tape. These indices were measured before surgery and 3 months and 1 year after surgery. Results Overall, AT, VFI, and TST were lower, whereas sclerotin, protein, skeletal muscle, TBW, ICW, ECW, TEE, and BM were higher in acromegaly patients. Postoperatively, TST rose initially and then decreased, the waistline increased, and sclerotin, skeletal muscle, TEE, and BM decreased. Changes in these indices differed with gender and age in unique patterns. Conclusions Body composition and metabolism in acromegaly patients changed after surgery, and gender and age influenced these changes. PMID:29531529

  17. Positive effects of refugee presence on host community nutritional status in Turkana County, Kenya.

    Science.gov (United States)

    Gengo, Rieti G; Oka, Rahul C; Vemuru, Varalakshmi; Golitko, Mark; Gettler, Lee T

    2018-01-01

    Refugee camps are often assumed to negatively impact local host communities through resource competition and conflict. We ask instead whether economic resources and trade networks associated with refugees have benefits for host community health and nutrition. To address this question we assess the impacts of Kakuma Refugee Camp in northwest Kenya, comparing anthropometric indicators of nutritional status between Turkana communities in the region. Participants were recruited at four sites in Turkana County (N = 586): Kakuma Town, adjacent to Kakuma Refugee Camp; Lorugum, an area with sustained economic development; Lokichoggio, formerly host to international NGOs, and now underdeveloped; and Lorengo, an undeveloped, rural community. We evaluated nutritional status using summed skinfold thickness and body mass index (BMI). Structured interviews provided contextual data. Age-controlled multiple regression models reveal two distinct skinfold thickness profiles for both sexes: comparatively elevated values in Kakuma and Lorugum, and significantly lower values in Lorengo and Lokichoggio. BMI did not vary significantly by location. Despite better nutritional status, a large proportion of Kakuma residents still report worries about basic needs, including hunger, health, and economic security. Kakuma Refugee Camp is associated with better host community energetic status indicators, compared to other relevant, regional sites varying in development and resources. Based on global nutritional standards, observed differences likely represent meaningful disparities in overall health. We suggest that access to cereals via refugee trade networks and employment might mediate this relationship. However, perceptions of refugees as illegitimate interlopers maintain a high psychological burden. © 2017 Wiley Periodicals, Inc.

  18. An Open-label Randomized Controlled Trial to Compare Weight Gain of Very Low Birth Weight Babies with or without Addition of Coconut Oil to Breast Milk.

    Science.gov (United States)

    Arun, Sumitha; Kumar, Manish; Paul, Thomas; Thomas, Nihal; Mathai, Sarah; Rebekah, Grace; Thomas, Niranjan

    2018-03-23

    Nutritional guidelines involving the feeding of very low birth weight babies (VLBW) recommend addition of Human Milk Fortifiers to breast milk. Owing to financial constraints, it is a practice in low- and middle-income countries (LMIC) to add coconut oil to aid better weight gain. There are inadequate data on improvement of growth parameters with oral coconut oil supplementation of breast milk. In this randomized controlled trial, we measured growth parameters and body composition of 60 babies who received either breast milk with coconut oil or breast milk alone. Randomization was stratified according to intrauterine growth appropriate for gestational age (n = 30) and small for gestational age (n = 30). There was no difference in weight gain between the two groups. The weight gain velocity was 15 ± 3.6 and 14.4 ± 3.4 g/kg/day (p value = 0.49) in the breast milk alone and in the breast milk with coconut oil group, respectively. There was no difference in increase in head circumference and length. Triceps skinfold thickness (n = 56) was similar in both groups, but subscapular skinfold thickness was significantly more in the coconut oil group. Total body fat percentage did not differ between the groups (25.2 ± 4.3 vs. 25.5 ± 4.3%, p = 0.79). Oral supplementation of coconut oil along with breast milk did not increase growth parameters or result in change in body composition in very low birth weight (VLBW) babies.

  19. [Systematic review of fall-related factors among the house-dwelling elderly in Japan].

    Science.gov (United States)

    Ueno, Megumi; Kawai, Sachio; Mino, Tairai; Kamoshita, Hiroshi

    2006-01-01

    Fall-related factors and individual characteristics of the elderly who have had fall are necessary to develop practical fall prevention programs, and life support management. However, no nation-wide meta-analysis of the fall-related factors of elderly has been performed in Japan. To conduct a meta-analysis concerning fall-related factors among the house-dwelling elderly in Japan. Japana Centra Revuo Medicina, version 3 (systematic literature search system for Japanese literature), and Pub Med (a service of the National Library of Medicine) from January 1994 to December 2003. Study search terms included the following: retrograde case-control, prospective cohort, and retrospective cohort study with falls. Search terms included older adults (60 years and over), falls and humans. Thirty-two fall-related factors were meta-analyzed. Among 32 fall-related factors, only nine factors were statistically proven to be related to falls. These factors were female gender, age over 70 years old, fall experience, past history of cerebrovascular disease, grip strength, knee extensor strength, one foot standing time with eyes open, one foot standing time with eyes closed, and skinfold thickness (female). Eleven factors: presence of a spouse, past medical history of hypertension, complaints of dizziness, numbness of the extremities, 10 meter maximum walking velocity, tendency to stumble, use of supportive equipment, standing postural sway. sitting trunk flexion, skinfold thickness (male), and body mass index, were not statistically proven to be related to falls. More studies are necessary to determine the efficacy of fall-related factors among the Japanese elderly.

  20. Enteral nutrition in inflammatory bowel disease.

    Science.gov (United States)

    Gassull, M A; Abad, A; Cabré, E; González-Huix, F; Giné, J J; Dolz, C

    1986-01-01

    To assess the effect of the addition of enteral tube feeding with polymeric diets to the standard treatment of acute attacks of inflammatory bowel disease a total of 43 patients admitted to hospital (23 with Crohn's disease and 20 with ulcerative colitis) were studied retrospectively. Total enteral nutrition was given to 26 as the sole nutritional supply and to 17 in conjunction with a normal ward diet, when appropriate, according to the severity of attack (control group). Nutritional state was assessed and classified in all patients at admission and at the end of the study, by measuring the triceps skinfold thickness, mid arm muscle circumference, and serum albumin concentration as representative of body fat, muscle protein, and visceral protein, respectively. At admission the three nutritional variables were not statistically different between the groups. There was a significantly positive effect on mid arm muscle circumference in patients on total enteral nutrition compared with the control group, but there was no effect on either triceps skinfold thickness or serum albumin concentration. The percentage of subjects requiring intravenous albumin infusion, however, was significantly less in the group fed enterally than in the control group. In addition, fewer patients in the group fed enterally required surgical treatment compared with the control group, despite the fact that one of the criteria for starting enteral nutritional support was the expectancy that surgery would be needed. Total enteral nutrition was well tolerated and no major side effects arose during its use in patients with acute exacerbations of inflammatory bowel disease. PMID:3098646

  1. Film thickness determination by grazing incidence diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Battiston, G A; Gerbasi, R [CNR, Padua (Italy). Istituto di Chimica e Tecnologie Inorganiche e dei Materiali Avanzati

    1996-09-01

    Thin films deposited via MOCVD (Metal Organic Chemical Vapour Deposition) are layers in the thickness range of a few manometers to about ten micrometers. An understanding of the physics and chemistry of films is necessary for a better comprehension of the phenomena involved in the film deposition procedure and its optimisation. Together with the crystalline phase a parameter that must be determined is the thickness of the layer. In this work the authors present a method for the measurement of the film thickness. This procedure, based on diffraction intensity absorption of the X-rays, both incident and diffracted in passing through the layers, resulted quite simple, rapid and non-destructive.

  2. Residual stress analysis in thick uranium films

    International Nuclear Information System (INIS)

    Hodge, A.M.; Foreman, R.J.; Gallegos, G.F.

    2005-01-01

    Residual stress analysis was performed on thick, 1-25 μm, depleted uranium (DU) films deposited on an Al substrate by magnetron sputtering. Two distinct characterization techniques were used to measure substrate curvature before and after deposition. Stress evaluation was performed using the Benabdi/Roche equation, which is based on beam theory of a bi-layer material. The residual stress evolution was studied as a function of coating thickness and applied negative bias voltage (0, -200, -300 V). The stresses developed were always compressive; however, increasing the coating thickness and applying a bias voltage presented a trend towards more tensile stresses and thus an overall reduction of residual stresses

  3. Film thickness determination by grazing incidence diffraction

    International Nuclear Information System (INIS)

    Battiston, G. A.; Gerbasi, R.

    1996-01-01

    Thin films deposited via MOCVD (Metal Organic Chemical Vapour Deposition) are layers in the thickness range of a few manometers to about ten micrometers. An understanding of the physics and chemistry of films is necessary for a better comprehension of the phenomena involved in the film deposition procedure and its optimisation. Together with the crystalline phase a parameter that must be determined is the thickness of the layer. In this work the authors present a method for the measurement of the film thickness. This procedure, based on diffraction intensity absorption of the X-rays, both incident and diffracted in passing through the layers, resulted quite simple, rapid and non-destructive

  4. Turbine airfoil with outer wall thickness indicators

    Science.gov (United States)

    Marra, John J; James, Allister W; Merrill, Gary B

    2013-08-06

    A turbine airfoil usable in a turbine engine and including a depth indicator for determining outer wall blade thickness. The airfoil may include an outer wall having a plurality of grooves in the outer surface of the outer wall. The grooves may have a depth that represents a desired outer surface and wall thickness of the outer wall. The material forming an outer surface of the outer wall may be removed to be flush with an innermost point in each groove, thereby reducing the wall thickness and increasing efficiency. The plurality of grooves may be positioned in a radially outer region of the airfoil proximate to the tip.

  5. Influence of the slice thickness in CT to clinical effect

    International Nuclear Information System (INIS)

    Kimura, Kazue; Katakura, Toshihiko; Ito, Masami; Okuaki, Okihisa; Suzuki, Kenji

    1980-01-01

    CT is a kind of tomography. Therefore, what thickness of tissue is being observed in the picture - this is important in the clinical application of CT. The influence of slice thickness on the pictures, especially its clinical effect, was examined. The apparatus used is EMI CT 5005. For varying the slice thickness, it cannot be any larger than the thickness essential to the apparatus. Therefore, to make it thinner than the essential 14 mm, collimators were specially prepared, which were used on the sides of an X-ray tube and a detector. As basic observation, the revelation ability of form owing to the difference of slice thickness using acryl pipes, and the revelation ability of slice face owing to the difference of slice thickness, were examined. About clinical observation, the results for certain cases of cancer were compared with the CT images for the slice thickness of 14 mm essential to EMI CT 5005 and the slice thickness of 7 mm achieved by means of the collimators. (J.P.N.)

  6. Changes of freshwater-lens thickness in basaltic island aquifers overlain by thick coastal sediments

    Science.gov (United States)

    Rotzoll, Kolja; Oki, Delwyn S.; El-Kadi, Aly I.

    2010-01-01

    Freshwater-lens thickness and long-term changes in freshwater volume in coastal aquifers are commonly assessed through repeated measurement of salinity profiles from monitor wells that penetrate into underlying salt water. In Hawaii, the thickest measured freshwater lens is currently 262 m in dike-free, volcanic-rock aquifers that are overlain by thick coastal sediments. The midpoint depth (depth where salinity is 50% salt water) between freshwater and salt water can serve as an indicator for freshwater thickness. Most measured midpoints have risen over the past 40 years, indicating a shrinking lens. The mean rate of rise of the midpoint from 1999–2009 varied locally, with faster rates in highly developed areas (1.0 m/year) and slower rates in less developed areas (0.5 m/year). The thinning of the freshwater lenses is the result of long-term groundwater withdrawal and reduced recharge. Freshwater/salt-water interface locations predicted from measured water levels and the Ghyben-Herzberg principle may be deeper than measured midpoints during some periods and shallower during other periods, although depths may differ up to 100 m in some cases. Moreover, changes in the midpoint are slower than changes in water level. Thus, water levels may not be a reliable indicator of the amount of freshwater in a coastal aquifer.

  7. Accurate thickness measurement of graphene

    International Nuclear Information System (INIS)

    Shearer, Cameron J; Slattery, Ashley D; Stapleton, Andrew J; Shapter, Joseph G; Gibson, Christopher T

    2016-01-01

    Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1–1.3 nm to 0.1–0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials. (paper)

  8. Thickness and roughness measurements for air-dried longleaf pine bark

    Science.gov (United States)

    Thomas L. Eberhardt

    2015-01-01

    Bark thicknesses for longleaf pine (Pinus palustris Mill.) were investigated using disks collected from trees harvested on a 70-year-old plantation. Maximum inner bark thickness was relatively constant along the tree bole whereas maximum outer bark thickness showed a definite decrease from the base of the tree to the top. The minimum whole bark thickness followed the...

  9. Antecedent thermal injury worsens split-thickness skin graft quality: A clinically relevant porcine model of full-thickness burn, excision and grafting.

    Science.gov (United States)

    Carlsson, Anders H; Rose, Lloyd F; Fletcher, John L; Wu, Jesse C; Leung, Kai P; Chan, Rodney K

    2017-02-01

    Current standard of care for full-thickness burn is excision followed by autologous split-thickness skin graft placement. Skin grafts are also frequently used to cover surgical wounds not amenable to linear closure. While all grafts have potential to contract, clinical observation suggests that antecedent thermal injury worsens contraction and impairs functional and aesthetic outcomes. This study evaluates the impact of antecedent full-thickness burn on split-thickness skin graft scar outcomes and the potential mediating factors. Full-thickness contact burns (100°C, 30s) were created on the backs of anesthetized female Yorkshire Pigs. After seven days, burn eschar was tangentially excised and covered with 12/1000th inch (300μm) split-thickness skin graft. For comparison, unburned wounds were created by sharp excision to fat before graft application. From 7 to 120days post-grafting, planimetric measurements, digital imaging and biopsies for histology, immunohistochemistry and gene expression were obtained. At 120days post-grafting, the Observer Scar Assessment Scale, colorimetry, contour analysis and optical graft height assessments were performed. Twenty-nine porcine wounds were analyzed. All measured metrics of clinical skin quality were significantly worse (pskin graft quality, likely by multiple mechanisms including burn-related inflammation, microscopically inadequate excision, and dysregulation of tissue remodeling. A valid, reliable, clinically relevant model of full-thickness burn, excision and skin replacement therapy has been demonstrated. Future research to enhance quality of skin replacement therapies should be directed toward modulation of inflammation and assessments for complete excision. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  10. Soliton models for thick branes

    Energy Technology Data Exchange (ETDEWEB)

    Peyravi, Marzieh [Ferdowsi University of Mashhad, Department of Physics, School of Sciences, Mashhad (Iran, Islamic Republic of); Riazi, Nematollah [Shahid Beheshti University, Physics Department, Tehran (Iran, Islamic Republic of); Lobo, Francisco S.N. [Faculdade de Ciencias da Universidade de Lisboa, Instituto de Astrofisica e Ciencias do Espaco, Lisbon (Portugal)

    2016-05-15

    In this work, we present new soliton solutions for thick branes in 4+1 dimensions. In particular, we consider brane models based on the sine-Gordon (SG), φ{sup 4} and φ{sup 6} scalar fields, which have broken Z{sub 2} symmetry in some cases and are responsible for supporting and stabilizing the thick branes. The origin of the symmetry breaking in these models resides in the fact that the modified scalar field potential may have non-degenerate vacua. These vacua determine the cosmological constant on both sides of the brane. We also study the geodesic equations along the fifth dimension, in order to explore the particle motion in the neighborhood of the brane. Furthermore, we examine the stability of the thick branes, by determining the sign of the w{sup 2} term in the expansion of the potential for the resulting Schroedinger-like equation, where w is the five-dimensional coordinate. It turns out that the φ{sup 4} brane is stable, while there are unstable modes for certain ranges of the model parameters in the SG and φ{sup 6} branes. (orig.)

  11. Reliability Criteria for Thick Bonding Wire.

    Science.gov (United States)

    Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa

    2018-04-17

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  12. Reliability Criteria for Thick Bonding Wire

    Science.gov (United States)

    Yavuz, Mustafa

    2018-01-01

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194

  13. Facial soft tissue thickness in North Indian adult population

    Directory of Open Access Journals (Sweden)

    Tanushri Saxena

    2012-01-01

    Full Text Available Objectives: Forensic facial reconstruction is an attempt to reproduce a likeness of facial features of an individual, based on characteristics of the skull, for the purpose of individual identification - The aim of this study was to determine the soft tissue thickness values of individuals of Bareilly population, Uttar Pradesh, India and to evaluate whether these values can help in forensic identification. Study design: A total of 40 individuals (19 males, 21 females were evaluated using spiral computed tomographic (CT scan with 2 mm slice thickness in axial sections and soft tissue thicknesses were measured at seven midfacial anthropological facial landmarks. Results: It was found that facial soft tissue thickness values decreased with age. Soft tissue thickness values were less in females than in males, except at ramus region. Comparing the left and right values in individuals it was found to be not significant. Conclusion: Soft tissue thickness values are an important factor in facial reconstruction and also help in forensic identification of an individual. CT scan gives a good representation of these values and hence is considered an important tool in facial reconstruction- This study has been conducted in North Indian population and further studies with larger sample size can surely add to the data regarding soft tissue thicknesses.

  14. Comparison of Different Approaches for Measuring Tibial Cartilage Thickness

    Directory of Open Access Journals (Sweden)

    Maier Jennifer

    2017-07-01

    Full Text Available Osteoarthritis is a degenerative disease affecting bones and cartilage especially in the human knee. In this context, cartilage thickness is an indicator for knee cartilage health. Thickness measurements are performed on medical images acquired in-vivo. Currently, there is no standard method agreed upon that defines a distance measure in articular cartilage. In this work, we present a comparison of different methods commonly used in literature. These methods are based on nearest neighbors, surface normal vectors, local thickness and potential field lines. All approaches were applied to manual segmentations of tibia and lateral and medial tibial cartilage performed by experienced raters. The underlying data were contrast agent-enhanced cone-beam C-arm CT reconstructions of one healthy subject’s knee. The subject was scanned three times, once in supine position and two times in a standing weight-bearing position. A comparison of the resulting thickness maps shows similar distributions and high correlation coefficients between the approaches above 0.90. The nearest neighbor method results on average in the lowest cartilage thickness values, while the local thickness approach assigns the highest values. We showed that the different methods agree in their thickness distribution. The results will be used for a future evaluation of cartilage change under weight-bearing conditions.

  15. Economical Fabrication of Thick-Section Ceramic Matrix Composites

    Science.gov (United States)

    Babcock, Jason; Ramachandran, Gautham; Williams, Brian; Benander, Robert

    2010-01-01

    A method was developed for producing thick-section [>2 in. (approx.5 cm)], continuous fiber-reinforced ceramic matrix composites (CMCs). Ultramet-modified fiber interface coating and melt infiltration processing, developed previously for thin-section components, were used for the fabrication of CMCs that were an order of magnitude greater in thickness [up to 2.5 in. (approx.6.4 cm)]. Melt processing first involves infiltration of a fiber preform with the desired interface coating, and then with carbon to partially densify the preform. A molten refractory metal is then infiltrated and reacts with the excess carbon to form the carbide matrix without damaging the fiber reinforcement. Infiltration occurs from the inside out as the molten metal fills virtually all the available void space. Densification to thick-section components required modification of the conventional process conditions, and the means by which the large amount of molten metal is introduced into the fiber preform. Modification of the low-temperature, ultraviolet-enhanced chemical vapor deposition process used to apply interface coatings to the fiber preform was also required to accommodate the high preform thickness. The thick-section CMC processing developed in this work proved to be invaluable for component development, fabrication, and testing in two complementary efforts. In a project for the Army, involving SiC/SiC blisk development, nominally 0.8 in. thick x 8 in. diameter (approx. 2 cm thick x 20 cm diameter) components were successfully infiltrated. Blisk hubs were machined using diamond-embedded cutting tools and successfully spin-tested. Good ply uniformity and extremely low residual porosity (41 ksi (approx. 283 MPa) flexural strength.

  16. Digital Thickness Measurement of a Transparent Plastic Orthodontic Device

    Science.gov (United States)

    Kim, Yoon-Hwan; Rhim, Sung-Han

    2018-05-01

    A transparent orthodontic device is used to move the teeth to the final calibration position to form a proper set of teeth. Because the uniform thickness of the device plays an important role in tooth positioning, the accuracy of the device's thickness profile is important for effective orthodontic treatment. However, due to the complexity of the device's geometry and the transparency of the device's material, measuring the complete thickness profile has been difficult. In the present study, a new optical scanning method to measure the thickness profile of transparent plastic orthodontic devices is proposed and evaluated by using scanning electron microscopy (SEM). The error of the new measurement method is less than ±18 μm. The new method can be used to measure the thickness of non-specific, multi-curved, transparent orthodontic devices.

  17. Barium titanate thick films prepared by screen printing technique

    Directory of Open Access Journals (Sweden)

    Mirjana M. Vijatović

    2010-06-01

    Full Text Available The barium titanate (BaTiO3 thick films were prepared by screen printing technique using powders obtained by soft chemical route, modified Pechini process. Three different barium titanate powders were prepared: i pure, ii doped with lanthanum and iii doped with antimony. Pastes for screen printing were prepared using previously obtained powders. The thick films were deposited onto Al2O3 substrates and fired at 850°C together with electrode material (silver/palladium in the moving belt furnace in the air atmosphere. Measurements of thickness and roughness of barium titanate thick films were performed. The electrical properties of thick films such as dielectric constant, dielectric losses, Curie temperature, hysteresis loop were reported. The influence of different factors on electrical properties values was analyzed.

  18. Increased endometrial thickness in women with hypertension.

    Science.gov (United States)

    Bornstein, J; Auslender, R; Goldstein, S; Kohan, R; Stolar, Z; Abramovici, H

    2000-09-01

    We noticed an increase in endometrial thickness in women with hypertension who were treated with a combination of medications, including beta-blockers. The purpose of this study was to examine whether the endometrium of hypertensive women is thicker than that of healthy women and to determine whether endometrial thickening in hypertensive women is directly related to the antihypertensive beta-blocker treatment. We compared 3 groups of postmenopausal patients as follows: (1) women with a history of essential hypertension treated with a combination of medications, including beta-blockers; (2) women with a history of hypertension treated with a combination of medications that did not include beta-blockers; and (3) healthy women without hypertension. All patients were interviewed and examined, blood tests were performed, and endometrial thickness in the anterior-posterior diameter was measured by vaginal ultrasonography. Among the exclusion criteria were diabetes or an abnormal fasting blood glucose level, obesity, hormonal medication or replacement hormonal therapy during the previous 6 months, and a history of hormonal disturbances, infertility, or polycystic ovary syndrome. Of 45 hypertensive women enrolled in the study, 22 were treated with a beta-blocker combination medication and 23 were treated with other antihypertensive medications. They were compared with 25 healthy women. There was no statistically significant difference in endometrial thickness between women treated with medications, including beta-blockers, and those who were treated with other hypotensive agents. Twenty percent of women with hypertension and none of the healthy women had endometrium >5 mm thick (P infinity). Twenty percent of hypertensive postmenopausal women were found to have increased endometrial thickness. However, we were unable to substantiate an association between the type of treatment administered, whether beta-blockers were included, and the increase in endometrial thickness.

  19. The effect of unilateral partial edentulism to muscle thickness

    International Nuclear Information System (INIS)

    Koca-Ceylan, Golzem; Guler, Ahmet U.; Taskay-Yelmir, Nergiz; Lutfi, Incesu; Aksoz, Tolga

    2003-01-01

    Teeth and muscle play a very important role for occlusal equilibrium and function.when tooth loss begins ,it may also effect the function of muscle tissues. The thickness of masseter and anterior temporalis muscles were measured bilaterally in 30 healthy fully dentate adults and in 30 unilateral edentulous patients by using ultrasonographic imaging. All scans were carried out by the same radiologist to eliminate the inter-observer difference, using a real time scanner (Toshiba SSA -270A,Japan). A 7.5 MHz linear transducer was used. The effect of age, sex, duration of partial edentulism, unilateral chewing habits of the individuals to the muscle thickness were also evaluated. In all subjects,facial proportion index was also determined. Main purpose of this study was to compare and establish the differences of muscle thickness between dentate and edentulous side in unilateral partial edentulous patients with ultrasonography and to test whether the variation in the thickness of the muscle is related to the variation in the facial and morphology. Ultrasonography revealed a large variation in the thickness of the masseter and temporolis muscles in experimental and controlled groups ,both relaxed and contracted conditions.The thickness of muscles in females was less in both conditions.In experimental group, a high negative correlation was found between the thickness of the masseter muscle and Facial Proportion Index ( FPI) in the females ,however, the statistical analysis showed no significant difference in the males. Also a high negative correlation was found in female control group. There was no statistically significant relationship between unilateral chewing habits and muscle thickness .In this study the duration of partial edentulism did not affect the thickness of the muscle.Further research is required to study muscular atrophy for comparison with total edentulism. (author)

  20. Vibration of Elastic Functionally Graded Thick Rings

    Directory of Open Access Journals (Sweden)

    Guang-Hui Xu

    2017-01-01

    Full Text Available The free vibration behaviors of functionally graded rings were investigated theoretically. The material graded in the thickness direction according to the power law rule and the rings were assumed to be in plane stress and plane strain states. Based on the first-order shear deformation theory and the kinetic relation of von Kárman type, the frequency equation for free vibration of functionally graded ring was derived. The derived results were verified by those in literatures which reveals that the present theory can be appropriate to predict the free vibration characteristics for quite thick rings with the radius-to-thickness ratio from 60 down to 2.09. Comparison between the plane stress case and the plane strain case indicates a slight difference. Meanwhile, the effects of the structural dimensional parameters and the material inhomogeneous parameter are examined. It is interesting that the value of the logarithmic form of vibration frequency is inversely proportional to the logarithmic form of the radius-to-thickness ratio or the mean radius.

  1. Topology of interaction between titin and myosin thick filaments.

    Science.gov (United States)

    Kellermayer, Miklós; Sziklai, Dominik; Papp, Zsombor; Decker, Brennan; Lakatos, Eszter; Mártonfalvi, Zsolt

    2018-05-05

    Titin is a giant protein spanning between the Z- and M-lines of the sarcomere. In the A-band titin is associated with the myosin thick filament. It has been speculated that titin may serve as a blueprint for thick-filament formation due to the super-repeat structure of its A-band domains. Accordingly, titin might provide a template that determines the length and structural periodicity of the thick filament. Here we tested the titin ruler hypothesis by mixing titin and myosin at in situ stoichiometric ratios (300 myosins per 12 titins) in buffers of different ionic strength (KCl concentration range 100-300 mM). The topology of the filamentous complexes was investigated with atomic force microscopy. We found that the samples contained distinct, segregated populations of titin molecules and myosin thick filaments. We were unable to identify complexes in which myosin molecules were regularly associated to either mono- or oligomeric titin in either relaxed or stretched states of the titin filaments. Thus, the electrostatically driven self-association is stronger in both myosin and titin than their binding to each other, and it is unlikely that titin functions as a geometrical template for thick-filament formation. However, when allowed to equilibrate configurationally, long myosin thick filaments appeared with titin oligomers attached to their surface. The titin meshwork formed on the thick-filament surface may play a role in controlling thick-filament length by regulating the structural dynamics of myosin molecules and placing a mechanical limit on the filament length. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Contribution to the study of slab thickness

    International Nuclear Information System (INIS)

    Moraitis, G.A.; Rorris, G.P.

    1978-01-01

    A method is proposed for calculating the time-independent values of the equivalent slab thickness of the ionosphere, defined as the ratio of the total electron content to the corresponding maximum electron density of the F region. Periodic variations of slab thickness are studied and are correlated to relative changes in exospheric temperature, deduced from the OGO-6 model

  3. Metatarsophalangeal joint extension changes ultrasound measurements for plantar fascia thickness.

    Science.gov (United States)

    Granado, Michael J; Lohman, Everett B; Gordon, Keith E; Daher, Noha S

    2018-01-01

    Ultrasound is an inexpensive method for quantifying plantar fascia thickness, especially in those with plantar fasciitis. Ultrasound has also been used to assess the effectiveness of various treatments for plantar fasciitis by comparing plantar fascia thickness before and after an intervention period. While a plantar fascia thickness over 4 mm via ultrasound has been proposed to be consistent with plantar fasciitis, some researchers believe the 4 mm plantar fascia thickness level to be a dubious guideline for diagnosing plantar fasciitis due to the lack of standardization of the measurement process for plantar fascia thickness. In particular, no universal guidelines exist on the positioning of the metatarsophalangeal (MTP) joints during the procedure and the literature also has inconsistent protocols. The purpose of this study is to investigate and compare the influence of MTP joint extension on plantar fascia thickness in healthy participants and those with unilateral plantar fasciitis. The plantar fascia thickness of forty participants (20 with unilateral plantar fasciitis and 20 control) was measured via ultrasound three times at three different MTP joint positions: 1) at rest, 2) 30° of extension from the plantar surface, and 3) maximal extension possible. The plantar fascia became significantly thinner as MTP joint extension increased in both the plantar fasciitis group ( p  plantar fasciitis group, the involved plantar fascia was 1.2 to 1.3 mm thicker (p plantar fascia thickness between the two sides was less than 0.1 mm ( p  plantar fascia thickness. It is recommended that plantar fascia thickness measurements be performed with the toes at rest. If MTP joints must be extended, then the toes should be extended maximally and then noted to ensure subsequent ultrasound procedures are repeated. Standardizing the position of the MTP joints is not only important for attaining the most accurate thickness measurement of the plantar fascia, but is also

  4. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  5. Reliability Criteria for Thick Bonding Wire

    Directory of Open Access Journals (Sweden)

    Turker Dagdelen

    2018-04-01

    Full Text Available Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al and aluminum coated copper (CucorAl wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  6. Precision of hyaline cartilage thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, K.; Buckwalter, K.; Helvie, M.; Niklason, L.; Martel, W. (Univ. of Michigan Hospitals, Ann Arbor, MI (United States). Dept. of Radiology)

    1992-05-01

    Measurement of cartilage thickness in vivo is an important indicator of the status of a joint as the various degenerative and inflammatory arthritides directly affect the condition of the cartilage. In order to assess the precision of thickness measurements of hyaline articular cartilage, we undertook a pilot study using MR imaging, plain radiography, and ultrasonography (US). We measured the cartilage of the hip and knee joints in 10 persons (4 healthy volunteers and 6 patients). The joints in each patient were examined on two separate occasions using each modality. In the hips a swell as the knee joints, the most precise measuring method was plain film radiography. For radiographs of the knees obtained in the standing position, the coefficient of variation was 6.5%; in the hips this figure was 6.34%. US of the knees and MR imaging of the hips were the second best modalities in the measurement of cartilage thickness. In addition, MR imaging enabled the most complete visualization of the joint cartilage. (orig.).

  7. The effect of the gas factor on selecting the thickness of a layer during two-layer getting of thick seams. [USSR

    Energy Technology Data Exchange (ETDEWEB)

    Varekha, Zh P; Kurkin, A S; Vechera, V N

    1979-01-01

    For technico-economic verification of the selection of the efficient removed thickness of upper and lower layers under conditions of high gas abundance of seams, the KNIUI has developed an economic model of converted costs within a getting field, allowing for natural and technical factors. The calculation considers specific costs for stoping work when getting the upper and lower layers, digging and maintenance of development workings, coal transport, assembly-disassembly work, ventilation, labor costs, degassing, etc. The calculation dependences and nomogram obtained enable comparatively easy definition of efficient thicknesses of removed layers when designing stoping work at thick, gently sloping seams, as well as calculation converted costs using as the initial data the total thickness of the seam, its natural gas content, and the expected degree of preliminary degassing.

  8. Accuracy of Visual Estimation of LASIK Flap Thickness.

    Science.gov (United States)

    Brenner, Jason E; Fadlallah, Ali; Hatch, Kathryn M; Choi, Catherine; Sayegh, Rony R; Kouyoumjian, Paul; Wu, Simon; Frangieh, George T; Melki, Samir A

    2017-11-01

    To assess the accuracy of surgeons' visual estimation of LASIK flap thickness when created by a femtosecond laser by comparing it to ultrasound measurements. Surgeons were asked to visually estimate the thickness of a femtosecond flap during the procedure. Total corneal thickness was measured by ultrasound pachymetry prior to the procedure and the stromal bed was similarly measured after flap lifting. The estimates from three experienced surgeons (cornea fellowship trained and more than 5 years in practice) were compared to those of three cornea fellows, with each surgeon evaluating 20 eyes (120 total). Surgeons were not told the thickness of the flaps unless required for safety reasons. The average difference between visual and ultrasonic estimation of LASIK flap thickness was 15.20 μm. The flap was 10 μm thicker than estimated in 37% of eyes, 20 μm thicker in 17% of eyes, and 30 μm thicker in 10% of eyes. The largest deviation was 53 μm. There was no statistically significant difference between the accuracy of experienced surgeons and fellows (P = .51). There are significant differences between surgeons' visual estimates and ultrasonic measurements of LASIK flap thickness. Relying on these visual estimates may lead to deeper excimer laser ablation than intended. This could lead to thinner residual stromal beds and higher percent tissue altered than planned. The authors recommend that surgeons measure flaps intraoperatively to maximize accuracy and safety. [J Refract Surg. 2017;33(11):765-767.]. Copyright 2017, SLACK Incorporated.

  9. Cortical thickness abnormalities in late adolescence with online gaming addiction.

    Science.gov (United States)

    Yuan, Kai; Cheng, Ping; Dong, Tao; Bi, Yanzhi; Xing, Lihong; Yu, Dahua; Zhao, Limei; Dong, Minghao; von Deneen, Karen M; Liu, Yijun; Qin, Wei; Tian, Jie

    2013-01-01

    Online gaming addiction, as the most popular subtype of Internet addiction, had gained more and more attention from the whole world. However, the structural differences in cortical thickness of the brain between adolescents with online gaming addiction and healthy controls are not well unknown; neither was its association with the impaired cognitive control ability. High-resolution magnetic resonance imaging scans from late adolescence with online gaming addiction (n = 18) and age-, education- and gender-matched controls (n = 18) were acquired. The cortical thickness measurement method was employed to investigate alterations of cortical thickness in individuals with online gaming addiction. The color-word Stroop task was employed to investigate the functional implications of the cortical thickness abnormalities. Imaging data revealed increased cortical thickness in the left precentral cortex, precuneus, middle frontal cortex, inferior temporal and middle temporal cortices in late adolescence with online gaming addiction; meanwhile, the cortical thicknesses of the left lateral orbitofrontal cortex (OFC), insula, lingual gyrus, the right postcentral gyrus, entorhinal cortex and inferior parietal cortex were decreased. Correlation analysis demonstrated that the cortical thicknesses of the left precentral cortex, precuneus and lingual gyrus correlated with duration of online gaming addiction and the cortical thickness of the OFC correlated with the impaired task performance during the color-word Stroop task in adolescents with online gaming addiction. The findings in the current study suggested that the cortical thickness abnormalities of these regions may be implicated in the underlying pathophysiology of online gaming addiction.

  10. High-throughput measurement of polymer film thickness using optical dyes

    Science.gov (United States)

    Grunlan, Jaime C.; Mehrabi, Ali R.; Ly, Tien

    2005-01-01

    Optical dyes were added to polymer solutions in an effort to create a technique for high-throughput screening of dry polymer film thickness. Arrays of polystyrene films, cast from a toluene solution, containing methyl red or solvent green were used to demonstrate the feasibility of this technique. Measurements of the peak visible absorbance of each film were converted to thickness using the Beer-Lambert relationship. These absorbance-based thickness calculations agreed within 10% of thickness measured using a micrometer for polystyrene films that were 10-50 µm. At these thicknesses it is believed that the absorbance values are actually more accurate. At least for this solvent-based system, thickness was shown to be accurately measured in a high-throughput manner that could potentially be applied to other equivalent systems. Similar water-based films made with poly(sodium 4-styrenesulfonate) dyed with malachite green oxalate or congo red did not show the same level of agreement with the micrometer measurements. Extensive phase separation between polymer and dye resulted in inflated absorbance values and calculated thickness that was often more than 25% greater than that measured with the micrometer. Only at thicknesses below 15 µm could reasonable accuracy be achieved for the water-based films.

  11. Tungsten thick coatings for plasma facing components

    International Nuclear Information System (INIS)

    Riccardi, B.; Pizzuto, A.; Orsini, A.; Libera, S.; Visca, E.; Bertamini, L.; Casadei, F.; Severini, E.; Montanari, R.; Litunovsky, N.

    1998-01-01

    The aim of the R and D activity was to realize thick W coatings on CuCrZr hollow bars and to test the mock ups with respect to thermal fatigue. Eight mock ups provided of 4 mm thick W coating were finally manufactured. The bonding integrity between coating and substrate was checked by means of an Ultrasonic apparatus. Characterisation of coatings was performed in order to assess microstructure, impurity content, density, tensile strength, adhesion strength, thermal conductivity and thermal expansion coefficient. Macroscopic residual strain measurements were performed by means of 'hole drilling' technique. The activities performed demonstrated the feasibility of thick Tungsten coatings on geometries with more complex residual strain distribution. These coatings are reliable armour of medium heat flux plasma facing component. (author)

  12. Multiple High Voltage Pulse Stressing of Polymer Thick Film Resistors

    Directory of Open Access Journals (Sweden)

    Busi Rambabu

    2014-01-01

    Full Text Available The purpose of this paper is to study high voltage interactions in polymer thick film resistors, namely, polyvinyl chloride- (PVC- graphite thick film resistors, and their applications in universal trimming of these resistors. High voltages in the form of impulses for various pulse durations and with different amplitudes have been applied to polymer thick film resistors and we observed the variation of resistance of these resistors with high voltages. It has been found that the resistance of polymer thick film resistors decreases in the case of higher resistivity materials and the resistance of polymer thick film resistor increases in the case of lower resistivity materials when high voltage impulses are applied to them. It has been also found that multiple high voltage pulse (MHVP stressing can be used to trim the polymer thick film resistors either upwards or downwards.

  13. Percolation effect in thick film superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Sali, R.; Harsanyi, G. [Technical Univ. of Budapest (Hungary)

    1994-12-31

    A thick film superconductor paste has been developed to study the properties of granulated superconductor materials, to observe the percolation effect and to confirm the theory of the conducting mechanism in the superconducting thick films. This paste was also applied to make a superconducting planar transformer. Due to high T{sub c} and advantageous current density properties the base of the paste was chosen to be of Bi(Pb)SrCaCuO system. For contacts a conventional Ag/Pt paste was used. The critical temperature of the samples were between 110 K and 115 K depending on the printed layer thickness. The critical current density at the boiling temperature of the liquid He- was between 200-300 A/cm{sup 2}. The R(T) and V(I) functions were measured with different parameters. The results of the measurements have confirmed the theory of conducting mechanism in the material. The percolation structure model has been built and described. As an application, a superconducting planar thick film transformer was planned and produced. Ten windings of the transformer were printed on one side of the alumina substrate and one winding was printed on the other side. The coupling between the two sides was possible through the substrate. The samples did not need special drying and firing parameters. After the preparation, the properties of the transformer were measured. The efficiency and the losses were determined. Finally, some fundamental advantages and problems of the process were discussed.

  14. Aluminum oxide film thickness and emittance

    International Nuclear Information System (INIS)

    Thomas, J.K.; Ondrejcin, R.S.

    1991-11-01

    Aluminum reactor components which are not actively cooled could be subjected to high temperatures due to gamma heating after the core coolant level dropped during the ECS phase of a hypothetical LOCA event. Radiative heat transfer is the dominant heat transfer process in this scenario and therefore the emittance of these components is of interest. Of particular interest are the safety rod thimbles and Mark 60B blanket assemblies; for the K Reactor, these components have been exposed to low temperature (< 55 degrees C) moderator for about a year. The average moderator temperature was assumed to be 30 degrees C. The Al oxide film thickness at this temperature, after one year of exposure, is predicted to be 6.4 μm ± 10%; insensitive to exposure time. Dehydration of the film during the gamma heating accident would result in a film thickness of 6.0 μm ± 11%. Total hemispherical emittance is predicted to be 0.69 at 96 degrees C, decreasing to 0.45 at 600 degrees C. Some phenomena which would tend to yield thicker oxide films in the reactor environment relative to those obtained under experimental conditions were neglected and the predicted film thickness values are therefore conservative. The emittance values predicted for a given film thickness are also conservative. The conservativisms inherent in the predicted emittance are particularly relevant for uncertainty analysis of temperatures generated using these values

  15. Percolation effect in thick film superconductors

    International Nuclear Information System (INIS)

    Sali, R.; Harsanyi, G.

    1994-01-01

    A thick film superconductor paste has been developed to study the properties of granulated superconductor materials, to observe the percolation effect and to confirm the theory of the conducting mechanism in the superconducting thick films. This paste was also applied to make a superconducting planar transformer. Due to high T c and advantageous current density properties the base of the paste was chosen to be of Bi(Pb)SrCaCuO system. For contacts a conventional Ag/Pt paste was used. The critical temperature of the samples were between 110 K and 115 K depending on the printed layer thickness. The critical current density at the boiling temperature of the liquid He- was between 200-300 A/cm 2 . The R(T) and V(I) functions were measured with different parameters. The results of the measurements have confirmed the theory of conducting mechanism in the material. The percolation structure model has been built and described. As an application, a superconducting planar thick film transformer was planned and produced. Ten windings of the transformer were printed on one side of the alumina substrate and one winding was printed on the other side. The coupling between the two sides was possible through the substrate. The samples did not need special drying and firing parameters. After the preparation, the properties of the transformer were measured. The efficiency and the losses were determined. Finally, some fundamental advantages and problems of the process were discussed

  16. A note on thick subcategories of stable derived categories

    OpenAIRE

    Krause, Henning; Stevenson, Greg

    2013-01-01

    For an exact category having enough projective objects, we establish a bijection between thick subcategories containing the projective objects and thick subcategories of the stable derived category. Using this bijection, we classify thick subcategories of finitely generated modules over strict local complete intersections and produce generators for the category of coherent sheaves on a separated Noetherian scheme with an ample family of line bundles.

  17. Practicable methods for histological section thickness measurement in quantitative stereological analyses.

    Science.gov (United States)

    Matenaers, Cyrill; Popper, Bastian; Rieger, Alexandra; Wanke, Rüdiger; Blutke, Andreas

    2018-01-01

    The accuracy of quantitative stereological analysis tools such as the (physical) disector method substantially depends on the precise determination of the thickness of the analyzed histological sections. One conventional method for measurement of histological section thickness is to re-embed the section of interest vertically to its original section plane. The section thickness is then measured in a subsequently prepared histological section of this orthogonally re-embedded sample. However, the orthogonal re-embedding (ORE) technique is quite work- and time-intensive and may produce inaccurate section thickness measurement values due to unintentional slightly oblique (non-orthogonal) positioning of the re-embedded sample-section. Here, an improved ORE method is presented, allowing for determination of the factual section plane angle of the re-embedded section, and correction of measured section thickness values for oblique (non-orthogonal) sectioning. For this, the analyzed section is mounted flat on a foil of known thickness (calibration foil) and both the section and the calibration foil are then vertically (re-)embedded. The section angle of the re-embedded section is then calculated from the deviation of the measured section thickness of the calibration foil and its factual thickness, using basic geometry. To find a practicable, fast, and accurate alternative to ORE, the suitability of spectral reflectance (SR) measurement for determination of plastic section thicknesses was evaluated. Using a commercially available optical reflectometer (F20, Filmetrics®, USA), the thicknesses of 0.5 μm thick semi-thin Epon (glycid ether)-sections and of 1-3 μm thick plastic sections (glycolmethacrylate/ methylmethacrylate, GMA/MMA), as regularly used in physical disector analyses, could precisely be measured within few seconds. Compared to the measured section thicknesses determined by ORE, SR measures displayed less than 1% deviation. Our results prove the applicability

  18. Pelvic floor muscle thickness measured by perineal ultrasonography

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen; Juul, N; Grønvall, S

    1991-01-01

    Pelvic floor muscle thickness was assessed in nine healthy female physiotherapists by perineal sonography. All measurements were performed as triple-measurements. The aims were to assess the reliability of the measurements and to establish a reference material. The muscle thickness at rest...

  19. Determination of accurate metal silicide layer thickness by RBS

    International Nuclear Information System (INIS)

    Kirchhoff, J.F.; Baumann, S.M.; Evans, C.; Ward, I.; Coveney, P.

    1995-01-01

    Rutherford Backscattering Spectrometry (RBS) is a proven useful analytical tool for determining compositional information of a wide variety of materials. One of the most widely utilized applications of RBS is the study of the composition of metal silicides (MSi x ), also referred to as polycides. A key quantity obtained from an analysis of a metal silicide is the ratio of silicon to metal (Si/M). Although compositional information is very reliable in these applications, determination of metal silicide layer thickness by RBS techniques can differ from true layer thicknesses by more than 40%. The cause of these differences lies in how the densities utilized in the RBS analysis are calculated. The standard RBS analysis software packages calculate layer densities by assuming each element's bulk densities weighted by the fractional atomic presence. This calculation causes large thickness discrepancies in metal silicide thicknesses because most films form into crystal structures with distinct densities. Assuming a constant layer density for a full spectrum of Si/M values for metal silicide samples improves layer thickness determination but ignores the underlying physics of the films. We will present results of RBS determination of the thickness various metal silicide films with a range of Si/M values using a physically accurate model for the calculation of layer densities. The thicknesses are compared to scanning electron microscopy (SEM) cross-section micrographs. We have also developed supporting software that incorporates these calculations into routine analyses. (orig.)

  20. Gauging the Galactic thick disk with RR Lyrae stars

    Directory of Open Access Journals (Sweden)

    Cruz G.

    2012-02-01

    Full Text Available In this contribution we present results from the QUEST RR Lyrae Survey of the thick disk. The survey spans ~480 sq. deg. at low latitude |b| < 30°, with multi-epoch VRI observations, obtained with the QUEST-I camera at the 1m Jürgen Stock Schmidt telescope located at the National Astronomical Observatory of Venezuela. This constitutes the first deep RR Lyrae survey of the Galactic thick disk conducted at low galactic latitudes, covering simultaneously a large range in radial (8thick disk structural parameters from in situ RR Lyrae stars having accurate distances (errors <7% and individual reddenings derived from each star’s color curve at minimum light. Moreover, the use of RR Lyrae stars as tracers ensures negligible contamination from the Galactic thin disk. We find a thick disk mean scale height hZ = 0.94 ± 0.11kpc and scale length hR = 3.2 ± 0.4kpc, derived from the vertical and radial mean density profiles of RR Lyrae stars. We also find evidence of thick disk flaring and results that may suggest the thick disk radial density profile shows signs of antitruncation. We discuss our findings in the context of recent thick disk formation models.

  1. Geologic thickness data: Candidate repository horizons

    International Nuclear Information System (INIS)

    Cross, R.W.; Fairchild, K.R.

    1985-01-01

    This data package contains information on the thickness of the Umtanum, McCoy Canyon, Cohassett, and Rocky Coulee flows and their intraflow structures in 20 boreholes and 2 surface sections in the Pasco Basin. Thickness data are for total flow, flow top, entablature, and colonnade (or just flow top and dense interior in some cases). Summary figures which contain descriptions and footages are included. SD-BWI-DP-011, Rev. 2 replaces SD-BWI-DP-011, Rev. A-0 in its entirety. (Rev. A-0 replaced Rev. 0-0.) 5 refs

  2. Compressive strength of thick composite panels

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    2011-01-01

    The aim of this study is to investigate how much the compressive strength of thick composite panels is reduced due to delaminations and to investigate under which conditions a delamination will grow. Understanding of this is essential in order to move forward the design limits used in the structu......The aim of this study is to investigate how much the compressive strength of thick composite panels is reduced due to delaminations and to investigate under which conditions a delamination will grow. Understanding of this is essential in order to move forward the design limits used...

  3. Advantages of PZT thick film for MEMS sensors

    DEFF Research Database (Denmark)

    Hindrichsen, Christian Carstensen; Lou-Moller, R.; Hansen, K.

    2010-01-01

    For all MEMS devices a high coupling between the mechanical and electrical domain is desired. Figures of merit describing the coupling are important for comparing different piezoelectric materials. The existing figures of merit are discussed and a new figure of merit is introduced for a fair comp....... Improved figure of merit is reached in the piezoelectric PZT thick film, TF2100CIP, by using cold isostatic pressure in the PZT preparation process. The porosity of TF2100 is decreased 38%, hence, allowing an increase of charge sensitivity for MEMS sensors of 59%....... thin film and PZT thick film. It is shown that MEMS sensors with the PZT thick film TF2100 from InSensor A/S have potential for significant higher voltage sensitivities compared to PZT thin film base MEMS sensors when the total thickness of the MEMS cantilever, beam, bridge or membrane is high...

  4. Kinetics of the crust thickness development of bread during baking.

    Science.gov (United States)

    Soleimani Pour-Damanab, Alireza; Jafary, A; Rafiee, Sh

    2014-11-01

    The development of crust thickness of bread during baking is an important aspect of bread quality and shelf-life. Computer vision system was used for measuring the crust thickness via colorimetric properties of bread surface during baking process. Crust thickness had a negative and positive relationship with Lightness (L (*) ) and total color change (E (*) ) of bread surface, respectively. A linear negative trend was found between crust thickness and moisture ratio of bread samples. A simple mathematical model was proposed to predict the development of crust thickness of bread during baking, where the crust thickness was depended on moisture ratio that was described by the Page moisture losing model. The independent variables of the model were baking conditions, i.e. oven temperature and air velocity, and baking time. Consequently, the proposed model had well prediction ability, as the mean absolute estimation error of the model was 7.93 %.

  5. Optimization of plastic scintillator thicknesses for online beta/gamma detection

    Directory of Open Access Journals (Sweden)

    Pourtangestani K.

    2012-04-01

    Full Text Available For efficient beta detection in a mixed beta gamma field, Monte Carlo simulation models have been built to optimize the thickness of a plastic scintillator, used in a whole body monitor. The simulation has been performed using the MCNP/X code for different thicknesses of plastic scintillator from 150 μm to 600 μm. The relationship between the thickness of the scintillator and the efficiency of the detector has been analyzed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be the optimum thickness for high efficiency beta detection in the presence of low energy gamma-rays.

  6. Nearshore sediment thickness, Fire Island, New York

    Science.gov (United States)

    Locker, Stanley D.; Miselis, Jennifer L.; Buster, Noreen A.; Hapke, Cheryl J.; Wadman, Heidi M.; McNinch, Jesse E.; Forde, Arnell S.; Stalk, Chelsea A.

    2017-04-03

    Investigations of coastal change at Fire Island, New York (N.Y.), sought to characterize sediment budgets and determine geologic framework controls on coastal processes. Nearshore sediment thickness is critical for assessing coastal system sediment availability, but it is largely unquantified due to the difficulty of conducting geological or geophysical surveys across the nearshore. This study used an amphibious vessel to acquire chirp subbottom profiles. These profiles were used to characterize nearshore geology and provide an assessment of nearshore sediment volume. Two resulting sediment-thickness maps are provided: total Holocene sediment thickness and the thickness of the active shoreface. The Holocene sediment section represents deposition above the maximum flooding surface that is related to the most recent marine transgression. The active shoreface section is the uppermost Holocene sediment, which is interpreted to represent the portion of the shoreface thought to contribute to present and future coastal behavior. The sediment distribution patterns correspond to previously defined zones of erosion, accretion, and stability along the island, demonstrating the importance of sediment availability in the coastal response to storms and seasonal variability. The eastern zone has a thin nearshore sediment thickness, except for an ebb-tidal deposit at the wilderness breach caused by Hurricane Sandy. Thicker sediment is found along a central zone that includes shoreface-attached sand ridges, which is consistent with a stable or accretional coastline in this area. The thickest overall Holocene section is found in the western zone of the study, where a thicker lower section of Holocene sediment appears related to the westward migration of Fire Island Inlet over several hundred years.

  7. Magma Supply of Southwest Indian Ocean: Implication from Crustal Thickness Anomalies

    Science.gov (United States)

    Chiheng, L.; Jianghai, L.; Huatian, Z.; Qingkai, F.

    2017-12-01

    The Southwest Indian Ridge (SWIR) is one of the world's slowest spreading ridges with a full spreading rate of 14mm a-1, belonging to ultraslow spreading ridge, which are a novel class of spreading centers symbolized by non-uniform magma supply and crustal accretion. Therefore, the crustal thickness of Southwest Indian Ocean is a way to explore the magmatic and tectonic process of SWIR and the hotspots around it. Our paper uses Residual Mantle Bouguer Anomaly processed with the latest global public data to invert the relative crustal thickness and correct it according to seismic achievements. Gravity-derived crustal thickness model reveals a huge range of crustal thickness in Southwest Indian Ocean from 0.04km to 24km, 7.5km of average crustal thickness, and 3.5km of standard deviation. In addition, statistics data of crustal thickness reveal the frequency has a bimodal mixed skewed distribution, which indicates the crustal accretion by ridge and ridge-plume interaction. Base on the crustal thickness model, we divide three types of crustal thickness in Southwest Indian Ocean. About 20.31% of oceanic crust is 9.8km thick as thick crust. Furthermore, Prominent thin crust anomalies are associated with the trend of most transform faults, but thick crust anomalies presents to northeast of Andrew Bain transform fault. Cold and depleted mantle are also the key factors to form the thin crust. The thick crust anomalies are constrained by hotspots, which provide abundant heat to the mantle beneath mid-ocean ridge or ocean basin. Finally, we roughly delineate the range of ridge-plume interaction and transform fault effect.

  8. Transmission electron microscopy of bulk specimens over 10 µm in thickness

    Energy Technology Data Exchange (ETDEWEB)

    Sadamatsu, Sunao, E-mail: sadamatsu@mech.kagoshima-u.ac.jp [Department of Mechanical Engineering, Kagoshima University, Korimoto, Kagoshima 890-0065 (Japan); Tanaka, Masaki; Higashida, Kenji [Department of Materials Science and Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Matsumura, Syo [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Ultramicroscopy Research Center, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-03-15

    We succeeded the observation of microstructures in bulk-sized specimens of over 10 µm in thickness by employing a technique that combines transmission electron microscopy (TEM) with energy-filtered imaging based on electron energy-loss spectroscopy (EELS). This method is unique in that it incorporates the inelastically scattered electrons into the imaging process. Using this technique, bright and sharp images of dislocations in crystalline silicon specimens as thick as 10 µm were obtained. A calibration curve to determine foil thickness of such a thick specimen was also derived. This method simply extends the observable thickness range in TEM. If combined with tilt series of observation over a significant range of angle, it will disclose three dimensional nanostructures in a µm-order block of a specimen, promoting our understanding of the controlling mechanisms behind various bulky material properties. - Highlights: • We developed a method which enables thick specimens to be observed using EF-TEM. • The effects of energy filter width and position on images were determined. • We suggested a method to determine the thickness of a thick film sample. • We achieved observation of microstructures in specimens with a thickness of 10 µm.

  9. Preparation of tantalum targets of known thicknesses

    International Nuclear Information System (INIS)

    Alexander, J.R.; Wirth, H.L.

    1985-01-01

    A series of carbon-backed tantalum targets were produced in a heavy ion sputtering system with a Penning ion source. The target thicknesses were then measured using the alpha-ray energy loss method. The resulting tabulated measurements were reproducible and make possible the production of carbon-backed tantalum targets with pre-determined thicknesses ranging from 20 μg/cm 2 to 1 mg/cm 2 . (orig.)

  10. Minimum Plate Thickness in High-Speed Craft

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup; Zhang, Shengming

    1998-01-01

    The minimum plate thickness requirements specified by the classification societies for high-speed craft are supposed to ensure adequate resistance to impact loads such as collision with floating objects and objects falling on the deck. The paper presents analytical methods of describing such impact...... phenomena and proposes performance requirements instead of thickness requirements for hull panels in high-speed craft made of different building materials....

  11. Cortical thickness abnormalities in late adolescence with online gaming addiction.

    Directory of Open Access Journals (Sweden)

    Kai Yuan

    Full Text Available Online gaming addiction, as the most popular subtype of Internet addiction, had gained more and more attention from the whole world. However, the structural differences in cortical thickness of the brain between adolescents with online gaming addiction and healthy controls are not well unknown; neither was its association with the impaired cognitive control ability. High-resolution magnetic resonance imaging scans from late adolescence with online gaming addiction (n = 18 and age-, education- and gender-matched controls (n = 18 were acquired. The cortical thickness measurement method was employed to investigate alterations of cortical thickness in individuals with online gaming addiction. The color-word Stroop task was employed to investigate the functional implications of the cortical thickness abnormalities. Imaging data revealed increased cortical thickness in the left precentral cortex, precuneus, middle frontal cortex, inferior temporal and middle temporal cortices in late adolescence with online gaming addiction; meanwhile, the cortical thicknesses of the left lateral orbitofrontal cortex (OFC, insula, lingual gyrus, the right postcentral gyrus, entorhinal cortex and inferior parietal cortex were decreased. Correlation analysis demonstrated that the cortical thicknesses of the left precentral cortex, precuneus and lingual gyrus correlated with duration of online gaming addiction and the cortical thickness of the OFC correlated with the impaired task performance during the color-word Stroop task in adolescents with online gaming addiction. The findings in the current study suggested that the cortical thickness abnormalities of these regions may be implicated in the underlying pathophysiology of online gaming addiction.

  12. Mandibular thickness measurements in young dentate adults.

    Science.gov (United States)

    Beaty, Narlin B; Le, Thomas T

    2009-09-01

    To measure thicknesses in clinical landmark areas of the dentate mandibles of young men and women. Using standard radiologic software, we obtained mean (SD) thickness measurements at the inferior or posterior borders of the mandible at the following 7 surgically useful sites: (1) the symphysis, (2) a point halfway between the symphysis and the mental nerve, (3) the mental nerve, (4) a point halfway between the mental nerve and the facial artery notch, (5) the facial artery notch, (6) the angle vertex, and (7) the ramus-condylar neck border. University hospital. A total of 150 dentate men and 75 dentate women aged 18 to 30 years who had undergone computed tomography of the head and neck region during the period of December 20, 2006 to February 20, 2007. Thicknesses of 7 mandibular sites. Mean (SD) thicknesses at the 7 mandibular sites were as follows: symphysis, 14.03 (1.53) mm for men and 13.21 (1.46) mm for women; halfway between the symphysis and the mental nerve, 11.17 (1.37) mm for men and 10.00 (1.08) mm for women; mental nerve, 9.48 (1.28) mm for men and 8.72 (1.00) mm for women; halfway between the mental nerve and the facial artery notch, 10.33 (1.24) mm for men and 9.45 (0.92) mm for women; facial artery notch, 7.27 (0.82) mm for men and 7.10 (0.88) mm for women; angle vertex, 5.42 (0.90) mm for men and 5.39 (0.66) mm for women; and ramus-condylar neck border, 5.90 (0.86) mm for men and 5.85 (0.71) mm for women. Clinical landmark areas in young dentate mandibles have mean thicknesses with limited SDs. The thickness measurements obtained at the sites in this study provide practical reference information for mandibular reconstruction and bicortical screw length estimation.

  13. Thickness Measurement of Surface Attachment on Plate with Lamb Wave

    Science.gov (United States)

    Ma, Xianglong; Zhang, Yinghong; Wen, Lichao; He, Yehu

    2017-12-01

    Aiming at the thickness detection of the plate surface attachment, a nondestructive testing method based on the Lamb wave is presented. This method utilizes Lamb wave propagation characteristics of signals in a bi-layer medium to measure the surface attachment plate thickness. Propagation of Lamb wave in bi-layer elastic is modeled and analyzed. The two-dimensional simulation model of electromagnetic ultrasonic plate - scale is established. The simulation is conducted by software COMSOL for simulation analysis under different boiler scale thickness wave form curve. Through this study, the thickness of the attached material can be judged by analyzing the characteristics of the received signal when the thickness of the surface of the plate is measured.

  14. Thickness Dependent on Photocatalytic Activity of Hematite Thin Films

    Directory of Open Access Journals (Sweden)

    Yen-Hua Chen

    2012-01-01

    Full Text Available Hematite (Fe2O3 thin films with different thicknesses are fabricated by the rf magnetron sputtering deposition. The effects of film thicknesses on the photocatalytic activity of hematite films have been investigated. Hematite films possess a polycrystalline hexagonal structure, and the band gap decreases with an increase of film thickness. Moreover, all hematite films exhibit good photocatalytic ability under visible-light irradiation; the photocatalytic activity of hematite films increases with the increasing film thickness. This is because the hematite film with a thicker thickness has a rougher surface, providing more reaction sites for photocatalysis. Another reason is a lower band gap of a hematite film would generate more electron-hole pairs under visible-light illumination to enhance photocatalytic efficiency. Experimental data are well fitted with Langmuir-Hinshelwood kinetic model. The photocatalytic rate constant of hematite films ranges from 0.052 to 0.068 min-1. This suggests that the hematite film is a superior photocatalyst under visible-light irradiation.

  15. Chemical constraints on the formation of the Galactic thick disk

    Directory of Open Access Journals (Sweden)

    Feltzing S.

    2012-02-01

    Full Text Available We highlight some results from our detailed abundance analysis study of 703 kinematically selected F and G dwarf stars in the solar neighbourhood. The analysis is based on spectra of high-resolution (R = 45000 to 110 000 and high signal-to-noise (S/N ≈ 150 to 300. The main findings include: (1 at a given metallicity, the thick disk abundance trends are more α-enhanced than those of the thin disk; (2 the metal-rich limit of the thick disk reaches at least solar metallicities; (3 the metal-poor limit of the thin disk is around [Fe/H] ≈−0.8; (4 the thick disk shows an age-metallicity gradient; (5 the thin disk does not show an age-metallicity gradient; (6 the most metal-rich thick disk stars at [Fe/H] ≈ 0 are significantly older than the most metal-poor thin disk stars at [Fe/H] ≈−0.7; (7 based on our elemental abundances we find that kinematical criteria produce thin and thick disk stellar samples that are biased in the sense that stars from the low-velocity tail of the thick disk are classified as thin disk stars, and stars from the high-velocity tail of the thin disk are classified as thick disk stars; (8 age criteria appears to produce thin and thick disk stellar samples with less contamination.

  16. Pelvic floor muscle thickness measured by perineal ultrasonography

    DEFF Research Database (Denmark)

    Bernstein, Inge Thomsen; Juul, N; Grønvall, S

    1991-01-01

    Pelvic floor muscle thickness was assessed in nine healthy female physiotherapists by perineal sonography. All measurements were performed as triple-measurements. The aims were to assess the reliability of the measurements and to establish a reference material. The muscle thickness at rest...... and at contraction was 9.4 +/- 0.8 mm and 11.5 +/- 1.1 mm respectively (mean +/- SD). Contraction increased the thickness by 2.2 +/- 0.8 mm or 23 +/- 8%. The intra- and inter observer standard deviation of the estimate was in the range of 4-6%. In conclusion, we find the reliability of the measurements acceptable....

  17. Synthesis of nanometre-thick MoO3 sheets

    Science.gov (United States)

    Kalantar-Zadeh, Kourosh; Tang, Jianshi; Wang, Minsheng; Wang, Kang L.; Shailos, Alexandros; Galatsis, Kosmas; Kojima, Robert; Strong, Veronica; Lech, Andrew; Wlodarski, Wojtek; Kaner, Richard B.

    2010-03-01

    The formation of MoO3 sheets of nanoscale thickness is described. They are made from several fundamental sheets of orthorhombic α-MoO3, which can be processed in large quantities via a low cost synthesis route that combines thermal evaporation and mechanical exfoliation. These fundamental sheets consist of double-layers of linked distorted MoO6 octahedra. Atomic force microscopy (AFM) measurements show that the minimum resolvable thickness of these sheets is 1.4 nm which is equivalent to the thickness of two double-layers within one unit cell of the α-MoO3 crystal.

  18. Rapid microcantilever-thickness determination by optical interferometry

    International Nuclear Information System (INIS)

    Salmon, Andrew R; Capener, Matthew J; Elliott, Stephen R; Baumberg, Jeremy J

    2014-01-01

    Silicon microcantilevers are widely used in scanning-probe microscopy and in cantilever-sensing applications. However, the cantilever thickness is not well controlled in conventional lithography and, since it is also difficult to measure, it is the most important undefined factor in mechanical variability. An accurate method to measure this parameter is thus essential. We demonstrate the capability to measure microcantilever thicknesses rapidly (>1 Hz) and accurately (±2 nm) by optical interferometry. This is achieved with standard microscopy equipment and so can be implemented as a standard technique in both research and in batch control for commercial microfabrication. In addition, we show how spatial variations in the thickness of individual microcantilevers can be mapped, which has applications in the precise mechanical calibration of cantilevers for force spectroscopy. (paper)

  19. Increased Cortical Thickness in Professional On-Line Gamers

    Science.gov (United States)

    Hyun, Gi Jung; Shin, Yong Wook; Kim, Bung-Nyun; Cheong, Jae Hoon; Jin, Seong Nam

    2013-01-01

    Objective The bulk of recent studies have tested whether video games change the brain in terms of activity and cortical volume. However, such studies are limited by several factors including cross-sectional comparisons, co-morbidity, and short-term follow-up periods. In the present study, we hypothesized that cognitive flexibility and the volume of brain cortex would be correlated with the career length of on-line pro-gamers. Methods High-resolution magnetic resonance scans were acquired in twenty-three pro-gamers recruited from StarCraft pro-game teams. We measured cortical thickness in each individual using FreeSurfer and the cortical thickness was correlated with the career length and the performance of the pro-gamers. Results Career length was positively correlated with cortical thickness in three brain regions: right superior frontal gyrus, right superior parietal gyrus, and right precentral gyrus. Additionally, increased cortical thickness in the prefrontal cortex was correlated with winning rates of the pro-game league. Increased cortical thickness in the prefrontal and parietal cortices was also associated with higher performance of Wisconsin Card Sorting Test. Conclusion Our results suggest that in individuals without pathologic conditions, regular, long-term playing of on-line games is associated with volume changes in the prefrontal and parietal cortices, which are associated with cognitive flexibility. PMID:24474988

  20. Convergent beam thickness determination of thin foil zirconium specimens

    International Nuclear Information System (INIS)

    Cann, C.D.

    1978-07-01

    The use of convergent beam patterns to determine the thickness of zirconium foils observed in the electron microscope has been investigated both theoretically and experimentally. On the basis of many-beam dynamical theory calculations, the [1012], [1013], and [1120] reflections at an accelerating voltage of 100 kV and the [1013], [1120], and [1122] reflections at 200 kV were found most suitable for convergent beam thickness determinations. Experimental convergent beam patterns were obtained in the JEOL-200B electron microscope under two different sets of conditions based on the size of the pattern desired. Computer assisted analysis of the patterns obtained gave foil thicknesses in good agreement with those determined from thickness extinction contours. (author)

  1. Organic photovoltaic effects depending on CuPc layer thickness

    International Nuclear Information System (INIS)

    Hur, Sung Woo; Kim, Tae Wan; Chung, Dong Hoe; Oh, Hyun Seok; Kim, Chung Hyeok; Lee, Joon Ung; Park, Jong Wook

    2004-01-01

    Organic photovoltaic effects were studied in device structures of ITO/CuPc/Al and ITO/CuPc/C 60 /BCP/Al by varying the CuPc layer thickness. Since the exciton diffusion length is relatively short in organic semiconductors, a study on the thickness-dependent photovoltaic effects is important. The thickness of the CuPc layer was varied from 10 nm to 50 nm. We found that the optimum CuPc layer thickness was around 40 nm from the analysis of the current density-voltage characteristics in an ITO/CuPc/Al photovoltaic cell. The efficiency of the device shows that the multi-layered heterojunction structure is more appropriate for photovoltaic cells.

  2. Film thickness determining method of the silicon isotope superlattices by SIMS

    International Nuclear Information System (INIS)

    Takano, Akio; Shimizu, Yasuo; Itoh, Kohei M.

    2008-01-01

    It is becoming important to evaluate silicon self-diffusion with progress of a silicon semiconductor industry. In order to evaluate the self-diffusion of silicon, silicon isotope superlattices (SLs) is the only marker. For this reason, it is important to correctly evaluate a film thickness and a depth distribution of isotope SLs by secondary ion mass spectrometry (SIMS). As for film thickness, it is difficult to estimate the thicknesses correctly if the cycles of SLs are short. In this work, first, we report the determination of the film thickness for short-period SLs using mixing roughness-information (MRI) analysis to SIMS profile. Next, the uncertainty of the conventional method to determine the film thicknesses of SLs is determined. It was found that the conventional methods cannot correctly determine film thickness of short-period-isotope SLs where film thickness differs for every layer

  3. Thickness-dependent spontaneous dewetting morphology of ultrathin Ag films

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, H; Favazza, C [Department of Physics, Washington University in St Louis, MO 63130 (United States); Sachan, R; Strader, J; Kalyanaraman, R [Department of Material Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Khenner, M, E-mail: ramki@utk.edu [Department of Mathematics, Western Kentucky University, Bowling Green, KY 42101 (United States)

    2010-04-16

    We show here that the morphological pathway of spontaneous dewetting of ultrathin Ag films on SiO{sub 2} under nanosecond laser melting is dependent on film thickness. For films with thickness h of 2 nm {<=} h {<=} 9.5 nm, the morphology during the intermediate stages of dewetting consisted of bicontinuous structures. For films with 11.5 nm {<=} h {<=} 20 nm, the intermediate stages consisted of regularly sized holes. Measurement of the characteristic length scales for different stages of dewetting as a function of film thickness showed a systematic increase, which is consistent with the spinodal dewetting instability over the entire thickness range investigated. This change in morphology with thickness is consistent with observations made previously for polymer films (Sharma and Khanna 1998 Phys. Rev. Lett. 81 3463-6; Seemann et al 2001 J. Phys.: Condens. Matter 13 4925-38). Based on the behavior of free energy curvature that incorporates intermolecular forces, we have estimated the morphological transition thickness for the intermolecular forces for Ag on SiO{sub 2}. The theory predictions agree well with observations for Ag. These results show that it is possible to form a variety of complex Ag nanomorphologies in a consistent manner, which could be useful in optical applications of Ag surfaces, such as in surface enhanced Raman sensing.

  4. Temperature- and thickness-dependent elastic moduli of polymer thin films

    Directory of Open Access Journals (Sweden)

    Ao Zhimin

    2011-01-01

    Full Text Available Abstract The mechanical properties of polymer ultrathin films are usually different from those of their counterparts in bulk. Understanding the effect of thickness on the mechanical properties of these films is crucial for their applications. However, it is a great challenge to measure their elastic modulus experimentally with in situ heating. In this study, a thermodynamic model for temperature- (T and thickness (h-dependent elastic moduli of polymer thin films Ef(T,h is developed with verification by the reported experimental data on polystyrene (PS thin films. For the PS thin films on a passivated substrate, Ef(T,h decreases with the decreasing film thickness, when h is less than 60 nm at ambient temperature. However, the onset thickness (h*, at which thickness Ef(T,h deviates from the bulk value, can be modulated by T. h* becomes larger at higher T because of the depression of the quenching depth, which determines the thickness of the surface layer δ.

  5. Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

    Energy Technology Data Exchange (ETDEWEB)

    Kim, No Hyu; Lee, Sang Soon [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2003-12-15

    This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process

  6. Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

    International Nuclear Information System (INIS)

    Kim, No Hyu; Lee, Sang Soon

    2003-01-01

    This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process

  7. Thick melanoma: prognostic value of positive sentinel nodes

    NARCIS (Netherlands)

    Vermeeren, Lenka; van der Ent, Fred W. C.; Sastrowijoto, Prapto S. H.; Hulsewé, Karel W. E.

    2009-01-01

    BACKGROUND: Sentinel lymph node biopsy (SNB) is a widely accepted procedure used to accurately stage patients with melanoma. Its value in patients with thick melanoma (Breslow thickness >4 mm) is reason for discussion because of the generally poor prognosis of these patients. The purpose of this

  8. Giant moving vortex mass in thick magnetic nanodots.

    Science.gov (United States)

    Guslienko, K Y; Kakazei, G N; Ding, J; Liu, X M; Adeyeye, A O

    2015-09-10

    Magnetic vortex is one of the simplest topologically non-trivial textures in condensed matter physics. It is the ground state of submicron magnetic elements (dots) of different shapes: cylindrical, square etc. So far, the vast majority of the vortex dynamics studies were focused on thin dots with thickness 5-50 nm and only uniform across the thickness vortex excitation modes were observed. Here we explore the fundamental vortex mode in relatively thick (50-100 nm) dots using broadband ferromagnetic resonance and show that dimensionality increase leads to qualitatively new excitation spectra. We demonstrate that the fundamental mode frequency cannot be explained without introducing a giant vortex mass, which is a result of the vortex distortion due to interaction with spin waves. The vortex mass depends on the system geometry and is non-local because of important role of the dipolar interaction. The mass is rather small for thin dots. However, its importance increases drastically with the dot thickness increasing.

  9. Randomized, Paired-Site Comparison of Autologous Engineered Skin Substitutes and Split-Thickness Skin Graft for Closure of Extensive, Full-Thickness Burns.

    Science.gov (United States)

    Boyce, Steven T; Simpson, Peggy S; Rieman, Mary T; Warner, Petra M; Yakuboff, Kevin P; Bailey, J Kevin; Nelson, Judith K; Fowler, Laura A; Kagan, Richard J

    Stable closure of full-thickness burn wounds remains a limitation to recovery from burns of greater than 50% of the total body surface area (TBSA). Hypothetically, engineered skin substitutes (ESS) consisting of autologous keratinocytes and fibroblasts attached to collagen-based scaffolds may reduce requirements for donor skin, and decrease mortality. ESS were prepared from split-thickness skin biopsies collected after enrollment of 16 pediatric burn patients into an approved study protocol. ESS and split-thickness autograft (AG) were applied to 15 subjects with full-thickness burns involving a mean of 76.9% TBSA. Data consisted of photographs, tracings of donor skin and healed wounds, comparison of mortality with the National Burn Repository, correlation of TBSA closed wounds with TBSA full-thickness burn, frequencies of regrafting, and immunoreactivity to the biopolymer scaffold. One subject expired before ESS application, and 15 subjects received 2056 ESS grafts. The ratio of closed wound to donor areas was 108.7 ± 9.7 for ESS compared with a maximum of 4.0 ± 0.0 for AG. Mortality for enrolled subjects was 6.25%, and 30.3% for a comparable population from the National Burn Repository (P burn generated an R value of 0.65 (P burns of greater than 50% TBSA.

  10. Anatomical characterization of central, apical and minimal corneal thickness

    Directory of Open Access Journals (Sweden)

    Federico Saenz-Frances

    2014-08-01

    Full Text Available AIM: To anatomically locate the points of minimum corneal thickness and central corneal thickness (pupil center in relation to the corneal apex.METHODS: Observational, cross-sectional study, 299 healthy volunteers. Thickness at the corneal apex (AT, minimum corneal thickness (MT and corneal thickness at the pupil center (PT were determined using the pentacam. Distances from the corneal apex to MT (MD and PT (PD were calculated and their quadrant position (taking the corneal apex as the reference determined:point of minimum thickness (MC and point of central thickness (PC depending on the quadrant position. Two multivariate linear regression models were constructed to examine the influence of age, gender, power of the flattest and steepest corneal axes, position of the flattest axis, corneal volume (determined using the Pentacam and PT on MD and PD. The effects of these variables on MC and PC were also determined in two multinomial regression models.RESULTS: MT was located at a mean distance of 0.909 mm from the apex (79.4% in the inferior-temporal quadrant. PT was located at a mean distance of 0.156 mm from the apex. The linear regression model for MD indicated it was significantly influenced by corneal volume (B=-0.024; 95%CI:-0.043 to -0.004. No significant relations were identified in the linear regression model for PD or the multinomial logistic regressions for MC and PC.CONCLUSION: MT was typically located at the inferior-temporal quadrant of the cornea and its distance to the corneal apex tended to decrease with the increment of corneal volume.

  11. Effect of maternal obesity on birthweight and neonatal fat mass: A prospective clinical trial.

    Directory of Open Access Journals (Sweden)

    Delphine Mitanchez

    Full Text Available To discriminate the effect of maternal obesity and gestational diabetes on birth weight and adipose tissue of the newborn.Normal BMI women (group N, n = 243; 18.5≤ BMI<25 kg/m2 and obese women (group Ob, n = 253; BMI≥30 kg/m2 were recruited in a prospective study between 15 and 18 weeks of gestation. All women were submitted to a 75g oral glucose tolerance test in the second and third trimester. First trimester fasting blood glucose was also obtained from Ob women. All women with one measurement above normal values were considered positive for gestational diabetes and first treated by dietary intervention. When dietary measures were not efficient, they were treated by insulin. Neonatal anthropometrics, sum of skinfolds and cord serum hormones were measured.222 N and 226 Ob mothers and their newborns were included in the analysis. Diabetes was diagnosed in 20% and 45.2% of N and Ob women, respectively. Birth weight was not statistically different between groups (boys: 3456g±433 and 3392g±463; girls: 3316g±402 and 3391g±408 for N and Ob, respectively. Multivariate analysis demonstrated that skinfold thickness and serum leptin concentrations were significantly increased in girls born to women with obesity (18.0mm±0.6 versus 19.7mm±0.5, p = 0.004 and 11.3ng/mL±1.0 versus 15.3ng/mL±1.0, p = 0.02, but not in boys (18.4mm±0.6 versus 18.5mm±0.5, p = 0.9 and 9.3ng/mL±1.0 versus 9.0ng/mL±1.0, p = 0.9. Based on data from 136 N and 124 Ob women, maternal insulin resistance at 37 weeks was also positively related to skinfold in girls, only, with a 1-point increase in HOMA-IR corresponding to a 0.33mm±0.08 increase in skinfold (p<0.0001.Regardless of gestational diabetes, maternal obesity and insulin resistance were associated with increased adiposity in girls only. Persistence of this sexual dimorphism remains to be explored during infancy.

  12. Accommodating Thickness in Origami-Based Deployable Arrays

    Science.gov (United States)

    Zirbel, Shannon A.; Magleby, Spencer P.; Howell, Larry L.; Lang, Robert J.; Thomson, Mark W.; Sigel, Deborah A.; Walkemeyer, Phillip E.; Trease, Brian P.

    2013-01-01

    The purpose of this work is to create deployment systems with a large ratio of stowed-to-deployed diameter. Deployment from a compact form to a final flat state can be achieved through origami-inspired folding of panels. There are many models capable of this motion when folded in a material with negligible thickness; however, when the application requires the folding of thick, rigid panels, attention must be paid to the effect of material thickness not only on the final folded state, but also during the folding motion (i.e., the panels must not be required to flex to attain the final folded form). The objective is to develop new methods for deployment from a compact folded form to a large circular array (or other final form). This paper describes a mathematical model for modifying the pattern to accommodate material thickness in the context of the design, modeling, and testing of a deployable system inspired by an origami six-sided flasher model. The model is demonstrated in hardware as a 1/20th scale prototype of a deployable solar array for space applications. The resulting prototype has a ratio of stowed-to-deployed diameter of 9.2 (or 1.25 m deployed outer diameter to 0.136 m stowed outer diameter).

  13. Partial Thickness Rotator Cuff Tears: Current Concepts

    Science.gov (United States)

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  14. Partial Thickness Rotator Cuff Tears: Current Concepts

    Directory of Open Access Journals (Sweden)

    Graeme Matthewson

    2015-01-01

    Full Text Available Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized.

  15. Metallicity gradient of the thick disc progenitor at high redshift

    Science.gov (United States)

    Kawata, Daisuke; Allende Prieto, Carlos; Brook, Chris B.; Casagrande, Luca; Ciucă, Ioana; Gibson, Brad K.; Grand, Robert J. J.; Hayden, Michael R.; Hunt, Jason A. S.

    2018-01-01

    We have developed a novel Markov Chain Monte Carlo chemical 'painting' technique to explore possible radial and vertical metallicity gradients for the thick disc progenitor. In our analysis, we match an N-body simulation to the data from the Apache Point Observatory Galactic Evolution Experiment survey. We assume that the thick disc has a constant scaleheight and has completed its formation at an early epoch, after which time radial mixing of its stars has taken place. Under these assumptions, we find that the initial radial metallicity gradient of the thick disc progenitor should not be negative, but either flat or even positive, to explain the current negative vertical metallicity gradient of the thick disc. Our study suggests that the thick disc was built-up in an inside-out and upside-down fashion, and older, smaller and thicker populations are more metal poor. In this case, star-forming discs at different epochs of the thick disc formation are allowed to have different radial metallicity gradients, including a negative one, which helps to explain a variety of slopes observed in high-redshift disc galaxies. This scenario helps to explain the positive slope of the metallicity-rotation velocity relation observed for the Galactic thick disc. On the other hand, radial mixing flattens the slope of an existing gradient.

  16. Measurement of compressed breast thickness by optical stereoscopic photogrammetry.

    Science.gov (United States)

    Tyson, Albert H; Mawdsley, Gordon E; Yaffe, Martin J

    2009-02-01

    The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.

  17. Measurement of subcutaneous adipose tissue thickness by near-infrared

    International Nuclear Information System (INIS)

    Wang, Yu; Ying, Zeqiang; Hao, Dongmei; Zhang, Song; Yang, Yimin; Zeng, Yanjun

    2013-01-01

    Obesity is strongly associated with the risks of diabetes and cardiovascular disease, and there is a need to measure the subcutaneous adipose tissue (SAT) layer thickness and to understand the distribution of body fat. A device was designed to illuminate the body parts by near-infrared (NIR), measure the backscattered light, and predict the SAT layer thickness. The device was controlled by a single-chip microcontroller (SCM), and the thickness value was presented on a liquid crystal display (LCD). There were 30 subjects in this study, and the measurements were performed on 14 body parts for each subject. The paper investigated the impacts of pressure and skin colour on the measurement. Combining with principal component analysis (PCA) and support vector regression (SVR), the measurement accuracy of SAT layer thickness was 89.1 % with a mechanical caliper as reference. The measuring range was 5–11 mm. The study provides a non-invasive and low-cost technique to detect subcutaneous fat thickness, which is more accessible and affordable compared to other conventional techniques. The designed device can be used at home and in community.

  18. A Study on the Thickness Measurement of Thin Film by Ultrasonic Wave

    International Nuclear Information System (INIS)

    Han, Eung Kyo; Lee, Jae Joon; Kim, Jae Yeol

    1988-01-01

    Recently, it is gradually raised necessity that thickness of thin film is measured accurately and managed in industrial circles and medical world. In this study, regarding to the thickness of film which is in opaque object and is beyond distance resolution capacity, thickness measurement was done by MEM-cepstrum analysis of received ultrasonic wave. In measurement results, film thickness which is beyond distance resolution capacity was measured accurately. And within thickness range that don't exist interference, thickness measurement by MEM-ceptrum analysis was impossible

  19. Substrate effects on terahertz metamaterial resonances for various metal thicknesses

    International Nuclear Information System (INIS)

    Park, S. J.; Ahn, Y. H.

    2014-01-01

    We demonstrate dielectric substrate effects on the resonance shift of terahertz metamaterials with various metal thicknesses by using finite-difference time-domain simulations. We found a small red shift in the metamaterial resonance with increasing metal thickness for the free-standing case. Conversely, when the metamaterial pattern was supported by a substrate with a high dielectric constant, the resonant frequency exhibited a large blue shift because the relative contribution of the substrate's refractive index to the resonant frequency decreased drastically as we increased the metal thickness. We determined the substrate's refractive index, 1.26, at which the metamaterial resonance was independent of the metal thickness. We extracted the effective refractive index as a function of the substrate's refractive index explicitly, which was noticeably different for different film thicknesses.

  20. Influence of thickness on properties of plasticized oat starch films

    Directory of Open Access Journals (Sweden)

    Melicia Cintia Galdeano

    2013-08-01

    Full Text Available The aim of this study was to investigate the effect of thickness (between 80 and 120 µm on apparent opacity, water vapor permeability and mechanical properties (tensile and puncture of oat starch films plasticized with glycerol, sorbitol, glycerol:sorbitol mixture, urea and sucrose. Films were stored under 11, 57, 76 and 90% relative humidity (RH to study the mechanical properties. It was observed that the higher the thickness, the higher was the opacity values. Films without the plasticizer were more opaque in comparison with the plasticized ones. Glycerol:sorbitol films presented increased elongation with increasing thickness at all RH. Puncture force showed a strong dependence on the film thickness, except for the films plasticized with sucrose. In general, thickness did not affect the water permeability.

  1. Pre-Treatment Deep Curettage Can Significantly Reduce Tumour Thickness in Thick Basal Cell Carcinoma While Maintaining a Favourable Cosmetic Outcome When Used in Combination with Topical Photodynamic Therapy

    International Nuclear Information System (INIS)

    Christensen, E.; Mork, C.; Foss, O. A.

    2011-01-01

    Topical photodynamic therapy (PDT) has limitations in the treatment of thick skin tumours. The aim of the study was to evaluate the effect of pre-PDT deep curettage on tumour thickness in thick (≥2 mm) basal cell carcinoma (BCC). Additionally, 3-month treatment outcome and change of tumour thickness from diagnosis to treatment were investigated. At diagnosis, mean tumour thickness was 2.3 mm (range 2.0-4.0). Pre- and post-curettage biopsies were taken from each tumour prior to PDT. Of 32 verified BCCs, tumour thickness was reduced by 50% after deep curettage (ρ≤0.001) . Mean tumour thickness was also reduced from diagnosis to treatment. At 3-month followup, complete tumour response was found in 93% and the cosmetic outcome was rated excellent or good in 100% of cases. In conclusion, deep curettage significantly reduces BCC thickness and may with topical PDT provide a favourable clinical and cosmetic short-term outcome.

  2. New Crustal Thickness for Djibouti, Afar, Using Seismic Techniques

    Science.gov (United States)

    Dugda, Mulugeta; Bililign, Solomon

    2008-10-01

    Crustal thickness and Poisson's ratio for the seismic station ATD in Djibouti, Afar, has been investigated using two seismic techniques (H-κ stacking of receiver functions and a joint inversion of receiver functions and surface wave group velocities). Both techniques give consistent results of crustal thickness 23±1.5 km and Poisson's ratio 0.31±0.02. We also determined a mean P-wave velocity (Vp) of ˜6.2 km/s but ˜6.9-7.0 km/s below a 2 - 5 km thick low velocity layer at the surface. Previous studies of crustal structure for Djibouti reported that the crust is 6 to 11 km thick while our study shows that the crust beneath Djibouti is between 20 and 25 km. This study argues that the crustal thickness values reported for Djibouti for the last 3 decades were not consistent with the reports for the other neighboring region in central and eastern Afar. Our results for ATD in Djibouti, however, are consistent with the reports of crustal thickness in many other parts of central and eastern Afar. We attribute this difference to how the Moho (the crust-mantle discontinuity) is defined (an increase of Vp to 7.4 km/s in this study vs. 6.9 km/s in previous studies).

  3. Thickness-dependent spontaneous dewetting morphology of ultrathin Ag films.

    Science.gov (United States)

    Krishna, H; Sachan, R; Strader, J; Favazza, C; Khenner, M; Kalyanaraman, R

    2010-04-16

    We show here that the morphological pathway of spontaneous dewetting of ultrathin Ag films on SiO2 under nanosecond laser melting is dependent on film thickness. For films with thickness h of 2 nm < or = h < or = 9.5 nm, the morphology during the intermediate stages of dewetting consisted of bicontinuous structures. For films with 11.5 nm < or = h < or = 20 nm, the intermediate stages consisted of regularly sized holes. Measurement of the characteristic length scales for different stages of dewetting as a function of film thickness showed a systematic increase, which is consistent with the spinodal dewetting instability over the entire thickness range investigated. This change in morphology with thickness is consistent with observations made previously for polymer films (Sharma and Khanna 1998 Phys. Rev. Lett. 81 3463-6; Seemann et al 2001 J. Phys.: Condens. Matter 13 4925-38). Based on the behavior of free energy curvature that incorporates intermolecular forces, we have estimated the morphological transition thickness for the intermolecular forces for Ag on SiO2. The theory predictions agree well with observations for Ag. These results show that it is possible to form a variety of complex Ag nanomorphologies in a consistent manner, which could be useful in optical applications of Ag surfaces, such as in surface enhanced Raman sensing.

  4. Estimation of sand dune thickness using a vertical velocity profile

    International Nuclear Information System (INIS)

    Al-Shuhail, Abdullatif A.

    2004-01-01

    Previous field and mathematical studies have shown that sand dunes may have vertical velocity profiles (i.e. continuous increase of velocity with depth). Therefore, computing the dunes thickness using conventional seismic refraction methods that assume a vertically homogeneous layer will likely produce some errors. The purpose of this study is to quantify the effect of the vertical velocity profile in a sand dune on the process of thickness estimation using seismic refraction data. First, the time distance (T-X) data of the direct wave in the dune is calculated using a vertical velocity profile, V (z), derived from Hertz-Mindlin contact theory. Then the thickness is estimated from the calculated T-X data, intercept time and velocity of the refractor at the dune's base assuming a constant velocity in the dune. The error in the estimated thickness due to the constant-velocity assumption increases with increasing thickness and decreasing porosity of the dune. For sand dunes with porosities greater than 0.2 and thickness less than 200 meter, the error is less than 15%. (author)

  5. Sunglasses with thick temples and frame constrict temporal visual field.

    Science.gov (United States)

    Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric

    2013-12-01

    Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p thick sunglasses" than with the "thin sunglasses" (p thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.

  6. Parametric Investigation of Optimum Thermal Insulation Thickness for External Walls

    Directory of Open Access Journals (Sweden)

    Omer Kaynakli

    2011-06-01

    Full Text Available Numerous studies have estimated the optimum thickness of thermal insulation materials used in building walls for different climate conditions. The economic parameters (inflation rate, discount rate, lifetime and energy costs, the heating/cooling loads of the building, the wall structure and the properties of the insulation material all affect the optimum insulation thickness. This study focused on the investigation of these parameters that affect the optimum thermal insulation thickness for building walls. To determine the optimum thickness and payback period, an economic model based on life-cycle cost analysis was used. As a result, the optimum thermal insulation thickness increased with increasing the heating and cooling energy requirements, the lifetime of the building, the inflation rate, energy costs and thermal conductivity of insulation. However, the thickness decreased with increasing the discount rate, the insulation material cost, the total wall resistance, the coefficient of performance (COP of the cooling system and the solar radiation incident on a wall. In addition, the effects of these parameters on the total life-cycle cost, payback periods and energy savings were also investigated.

  7. Radioisotope albedo method for measuring thickness of polymers coatings on metal basis

    International Nuclear Information System (INIS)

    Kapranov, B.I.; Myakin'kova, L.V.; Shaverin, V.A.

    1986-01-01

    Theoretical analysis of albedo thickness measuring of polymer coating-metal composite has been made and experimental studies of the range of tested thicknesses of polymer coating when different metal bases and radiation sources are used have been conducted. It is shown that the thickness of polymer coating on metal can be measured using backscattered γ-radiation in the energy range of 20-120 keV at the error 0.15-0.8 mm, at that, for thickness up to 23 mm the use of 147 Pm isotope can be defined as the optimum one; for thicknesses up to 40 mm 241 Am should be used; at thicknesses up to 60 mm - 57 Co. The AGAT-1 albedo gamma thickness gage, designed for measuring thickness of fiber glass coating up to 20 mm on metal base, is described

  8. Reflectance confocal microscopy features of thin versus thick melanomas.

    Science.gov (United States)

    Kardynal, Agnieszka; Olszewska, Małgorzata; de Carvalho, Nathalie; Walecka, Irena; Pellacani, Giovanni; Rudnicka, Lidia

    2018-01-24

    In vivo reflectance confocal microscopy (RCM) plays an increasingly important role in differential diagnosis of melanoma. The aim of the study was to assess typical confocal features of thin (≤1mm according to Breslow index) versus thick (>1mm) melanomas. 30 patients with histopathologically confirmed cutaneous melanoma were included in the study. Reflectance confocal microscopy was performed with Vivascope equipment prior to excision. Fifteen melanomas were thin (Breslow thickness ≤ 1mm) and 15 were thick melanomas (Breslow thickness >1mm). In the RCM examination, the following features were more frequently observed in thin compared to thick melanomas: edged papillae (26.7% vs 0%, p=0.032) and areas with honeycomb or cobblestone pattern (33.3% vs 6.7%, p=0.068). Both features are present in benign melanocytic lesions, so in melanoma are good prognostic factors. The group of thick melanomas compared to the group of thin melanomas in the RCM images presented with greater frequency of roundish cells (100% vs 40%, p=0.001), non-edged papillae (100% vs 60%, p=0.006), numerous pagetoid cells (73.3% vs 33.3%, p=0.028), numerous atypical cells at dermal-epidermal junction (53.3% vs 20%, p=0.058) and epidermal disarray (93.3% vs 66.7%, p=0.068). Non-invasive imaging methods helps in deepening of knowledge about the evolution and biology of melanoma. The most characteristic features for thin melanomas in confocal examination are: fragments of cobblestone or honeycomb pattern and edged papillae (as good prognostic factors). The features of thick melanomas in RCM examination are: roundish cells, non-edged papillae, numerous pagetoid cells at dermal-epidermal junction and epidermal disarray.

  9. The AMBRE project: The thick thin disk and thin thick disk of the Milky Way

    Science.gov (United States)

    Hayden, M. R.; Recio-Blanco, A.; de Laverny, P.; Mikolaitis, S.; Worley, C. C.

    2017-11-01

    We analyze 494 main sequence turnoff and subgiant stars from the AMBRE:HARPS survey. These stars have accurate astrometric information from Gaia DR1, providing reliable age estimates with relative uncertainties of ±1 or 2 Gyr and allowing precise orbital determinations. The sample is split based on chemistry into a low-[Mg/Fe] sequence, which are often identified as thin disk stellar populations, and high-[Mg/Fe] sequence, which are often associated with thick disk stellar populations. We find that the high-[Mg/Fe] chemical sequence has extended star formation for several Gyr and is coeval with the oldest stars of the low-[Mg/Fe] chemical sequence: both the low- and high-[Mg/Fe] sequences were forming stars at the same time. We find that the high-[Mg/Fe] stellar populations are only vertically extended for the oldest, most-metal poor and highest [Mg/Fe] stars. When comparing vertical velocity dispersion for the low- and high-[Mg/Fe] sequences, the high-[Mg/Fe] sequence has lower vertical velocity dispersion than the low-[Mg/Fe] sequence for stars of similar age. This means that identifying either group as thin or thick disk based on chemistry is misleading. The stars belonging to the high-[Mg/Fe] sequence have perigalacticons that originate in the inner disk, while the perigalacticons of stars on the low-[Mg/Fe] sequence are generally around the solar neighborhood. From the orbital properties of the stars, the high-[Mg/Fe] and low-[Mg/Fe] sequences are most likely a reflection of the chemical enrichment history of the inner and outer disk populations, respectively; radial mixing causes both populations to be observed in situ at the solar position. Based on these results, we emphasize that it is important to be clear in defining what populations are being referenced when using the terms thin and thick disk, and that ideally the term thick disk should be reserved for purely geometric definitions to avoid confusion and be consistent with definitions in external

  10. Surface states in thin versus thick organic quantum wells

    International Nuclear Information System (INIS)

    Nguyen Ba An; Hanamura, E.

    1995-08-01

    Surface states are studied in dependence on thickness or organic quantum wells within the nearest layer approximation. It is shown that there is a material-dependent critical thickness. Structures, that have thickness thinner or thicker than the critical one, exhibit qualitatively different characteristics of surface states. Criteria for existence and sign rules for location of energy levels of surface states are established which are general and contain the results of the previous works as particular cases. (author). 18 refs, 3 figs

  11. Association between obesity and depressive disorder in adolescents at high risk for depression.

    Science.gov (United States)

    Hammerton, G; Thapar, A; Thapar, A K

    2014-04-01

    To examine the relationship between Body Mass Index (BMI) and depressive disorder in adolescents at high risk for depression. Prospective longitudinal 3-wave study of offspring of parents with recurrent depression. Replication in population-based cohort study. Three hundred and thirty-seven families where offspring were aged 9-17 years at baseline and 10-19 years at the final data point. Replication sample of adolescents from population-based cohort study aged 11-13 years at first assessment and 14-17 years at follow-up. High risk sample used BMI, skin-fold thickness, Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV)-defined major depressive disorder and depression symptoms using the Child and Adolescent Psychiatric Assessment (CAPA). Replication sample used BMI, DSM-IV depressive disorder and depression symptoms using the Development and Well-Being Assessment (DAWBA). Two hundred and eighty-nine adolescents were included in the primary analyses. The mean BMI for each age group in this sample were significantly higher than population norms. There was no significant longitudinal association between categories of weight (or BMI) and new onset depressive disorder or depression symptoms. Similar results were found for skin-fold thickness. The association was also tested in a replication population-based sample and found to be non-significant in the subsample of offspring with mothers who had experienced recurrent depression in the past. BMI at age 12 years was, however, a significant predictor of depression symptoms but not of depressive disorder at age 15 years for the total unselected population. BMI does not significantly predict the development of depression in the offspring of parents with recurrent depression.

  12. [Physical activity of 9 and 15 year old Icelandic children - Public health objectives and relations of physical activity to gender, age, anthropometry and area of living].

    Science.gov (United States)

    Magnusson, Kristjan Thor; Arngrimsson, Sigurbjorn Arni; Sveinsson, Thorarinn; Johannsson, Erling

    2011-02-01

    The main objective of the study was to assess to what degree nine and fifteen year old Icelandic children followed the national physical activity (PA) guidelines for children set forth by the Icelandic Public Health Institute, which recommend no less than 60 minutes of moderate-to-vigorous physical activity a day (MVPA). The study was conducted between September 2003 and January 2004 at eighteen randomly selected schools in the capital area of Reykjavik and towns and rural areas in the northeast. All nine years old (N=662) and fifteen years old (N=661) students were offered to participate. Half of the children were randomly chosen to partake in the PA part of the study where 176 nine-year-old and 162 fifteen-year-old children yielded usable data. We measured participants' height, weight and skinfold thickness and their PA by ActiGraph™ with respect to moderate-to-vigorous intensity (defined as counts >3400 cpm) and average volume. Only 5% of 9-year-old and 9% of 15 year-old students followed the recommended PA guidelines of at least 60 minutes a day of MVPA. MVPA was positively associated with sex (being a boy) and age, but negatively associated with skinfold thickness. Those living in the capital area of Reykjavik rather than in smaller towns and rural areas were likelier to accrue more minutes of MVPA per day. The results highlight the importance of developing PA interventions targeting children of school age. It is important to research and evaluate different ways as to how these interventions should best be conducted. Key words: physical activity, children, body composition, accelerometers.

  13. Effect of race distance on muscle oxygenation in short-track speed skating.

    Science.gov (United States)

    Hesford, Catherine M; Laing, Stewart; Cardinale, Marco; Cooper, Chris E

    2013-01-01

    Previous work identified an asymmetry in tissue desaturation changes in the left and right quadriceps muscles during on-ice skating at maximal speed in males. The effect of changing race distance on the magnitude of desaturation or leg asymmetry is unknown. Six elite male skaters (age = 23 ± 1.8 yr, height = 1.8 ± 0.1 m, mass = 80.1 ± 5.7 kg, midthigh skinfold thickness = 7 ± 2 mm) and four elite female skaters (age = 21 ± 4 yr, height = 1.6 ± 0.1 m, mass = 65.2 ± 4.3 kg, midthigh skinfold thickness = 10 ± 1 mm) were studied. Subjects completed time trials over three race distances. Blood lactate concentration and O2 uptake measurements were combined with near-infrared spectroscopy measures of muscle oxygenation (TSI) and blood volume (tHb) in the right and left vastus lateralis. Neither race distance nor gender had a significant effect on the magnitude of maximal muscle desaturation (ΔTSI(max)). Pattern of local changes in tHb during individual laps was dependent upon subtle differences in skating technique used for the different race distances. Linear regression analysis revealed asymmetry between the right and left leg desaturation in males during the final stages of each race distance, but not in females. At all race distances, local muscle desaturation reached maximal values much more quickly than global VO(2peak). The use of wearable near-infrared spectroscopy devices enabled measurement of muscle oxygenation during competitive race simulation, thus providing unique insight into the effects of velocity and technique changes on local muscle oxygenation. This may have implications for training and race pacing in speed skating.

  14. Cortical thickness differences between bipolar depression and major depressive disorder.

    Science.gov (United States)

    Lan, Martin J; Chhetry, Binod Thapa; Oquendo, Maria A; Sublette, M Elizabeth; Sullivan, Gregory; Mann, J John; Parsey, Ramin V

    2014-06-01

    Bipolar disorder (BD) is a psychiatric disorder with high morbidity and mortality that cannot be distinguished from major depressive disorder (MDD) until the first manic episode. A biomarker able to differentiate BD and MDD could help clinicians avoid risks of treating BD with antidepressants without mood stabilizers. Cortical thickness differences were assessed using magnetic resonance imaging in BD depressed patients (n = 18), MDD depressed patients (n = 56), and healthy volunteers (HVs) (n = 54). A general linear model identified clusters of cortical thickness difference between diagnostic groups. Compared to the HV group, the BD group had decreased cortical thickness in six regions, after controlling for age and sex, located within the frontal and parietal lobes, and the posterior cingulate cortex. Mean cortical thickness changes in clusters ranged from 7.6 to 9.6% (cluster-wise p-values from 1.0 e-4 to 0.037). When compared to MDD, three clusters of lower cortical thickness in BD were identified that overlapped with clusters that differentiated the BD and HV groups. Mean cortical thickness changes in the clusters ranged from 7.5 to 8.2% (cluster-wise p-values from 1.0 e-4 to 0.023). The difference in cortical thickness was more pronounced when the subgroup of subjects with bipolar I disorder (BD-I) was compared to the MDD group. Cortical thickness patterns were distinct between BD and MDD. These results are a step toward developing an imaging test to differentiate the two disorders. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Research progress on the measurement of human lens thickness in vivo

    Directory of Open Access Journals (Sweden)

    Yu-Huan Yang

    2017-05-01

    Full Text Available The precise measurement in lens thickness in vivo, provides great application value for intraocular accommodation and ametropia development mechanism research. And it has great clinical significance for the diagnosis and treatment of glaucoma and cataract. Currently, many ultrasonic methods and optical methods are used in measuring lens thickness. The measurement principles, advantages, disadvantages and the accuracy of the instruments are summarized in this paper. Among these methods, Orbscan II, Pentacam, Lenstar and AS-OCT can be used to measure lens thickness instead of A-scan. More important is the fact that UL-OCT can dynamically monitor the change of the lens thickness with intraocular accommodation. Choosing an instrument with higher measuring accuracy to examine the lens thickness, can provide more accurate and convincing lens thickness data for clinical and scientific research.

  16. Thick domain wall spacetimes with and without reflection symmetry

    International Nuclear Information System (INIS)

    Melfo, Alejandra; Pantoja, Nelson; Skirzewski, Aureliano

    2003-01-01

    We show that different thick domain wall spacetimes, for which the scalar field configuration and the potential are the same, can be found as solutions to the coupled Einstein-scalar field equations, depending on whether or not reflection symmetry on the wall is imposed. Spacetimes with reflection symmetry may be dynamic or static, while the asymmetric ones are static. Asymmetric walls are asymptotically flat on one side and reduce to the Taub spacetime on the other. Examples of asymmetric thick walls in D-dimensional spacetimes are given, and previous analysis on the distributional thin-wall limit of the dynamic symmetric thick walls are extended to the asymmetric case. A new family of reflection symmetric, static thick domain wall spacetimes, including previously known Bogomol'nyi-Prasad-Sommerfield walls, is presented

  17. [Preliminary analysis about influence of porcelain thickness on interfacial crack of PFM].

    Science.gov (United States)

    Zhu, Ziyuan; Zhang, Baowei; Zhang, Xiuyin; Xu, Kan; Fang, Ruhua; Wang, Dongmei

    2002-01-01

    This study was about the influence of porcelain thickness on crack at interface. The effect of porcelain thickness on the flaw at the interface between porcelain and metal was studied in three groups with porcelain thickness of 0.5 mm, 1.5 mm and 2.5 mm (metal thickness of 0.5 mm) by means of moire interferometre and interfacial fracture mechanics. The parameter Jc was compared among the three groups and the growing of the flaw was observed. Jc and the extreme strength of group with porcelain thickness of 0.5 mm (2.813 N/m and 9.979 N) were lower than those of the groups with porcelain thickness of 1.5 mm and 2.5 mm (5.395 N/m, 19.134 N and 5.429 N/m, 19.256 N). Flaws extend along the interface in the groups with porcelain thickness of 1.5 mm and 0.5 mm. (1) Fracture resistance of the interface in the groups with porcelain thickness of 1.5 mm and 2.5 mm is similar and it decreases in the group with 0.5 mm thick porcelain. (2) When porcelain is 1.5 mm or 0.5 mm thick, flaws will extend along the interface. When porcelain is 2.5 mm thick, flaws will extend into the porcelain layer.

  18. Retrieval of ice thickness from polarimetric SAR data

    Science.gov (United States)

    Kwok, R.; Yueh, S. H.; Nghiem, S. V.; Huynh, D. D.

    1993-01-01

    We describe a potential procedure for retrieving ice thickness from multi-frequency polarimetric SAR data for thin ice. This procedure includes first masking out the thicker ice types with a simple classifier and then deriving the thickness of the remaining pixels using a model-inversion technique. The technique used to derive ice thickness from polarimetric observations is provided by a numerical estimator or neural network. A three-layer perceptron implemented with the backpropagation algorithm is used in this investigation with several improved aspects for a faster convergence rate and a better accuracy of the neural network. These improvements include weight initialization, normalization of the output range, the selection of offset constant, and a heuristic learning algorithm. The performance of the neural network is demonstrated by using training data generated by a theoretical scattering model for sea ice matched to the database of interest. The training data are comprised of the polarimetric backscattering coefficients of thin ice and the corresponding input ice parameters to the scattering model. The retrieved ice thickness from the theoretical backscattering coefficients is compare with the input ice thickness to the scattering model to illustrate the accuracy of the inversion method. Results indicate that the network convergence rate and accuracy are higher when multi-frequency training sets are presented. In addition, the dominant backscattering coefficients in retrieving ice thickness are found by comparing the behavior of the network trained backscattering data at various incidence angels. After the neural network is trained with the theoretical backscattering data at various incidence anges, the interconnection weights between nodes are saved and applied to the experimental data to be investigated. In this paper, we illustrate the effectiveness of this technique using polarimetric SAR data collected by the JPL DC-8 radar over a sea ice scene.

  19. Phase Space Exchange in Thick Wedge Absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, David [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-01-01

    The problem of phase space exchange in wedge absorbers with ionization cooling is discussed. The wedge absorber exchanges transverse and longitudinal phase space by introducing a position-dependent energy loss. In this paper we note that the wedges used with ionization cooling are relatively thick, so that single wedges cause relatively large changes in beam phase space. Calculation methods adapted to such “thick wedge” cases are presented, and beam phase-space transformations through such wedges are discussed.

  20. A study of compressed breast thickness at Hirosaki University Hospital

    International Nuclear Information System (INIS)

    Kon, Masanori; Osanai, Tsunemi; Ootani, Yuhiko; Sugawara, Kaoru; Abe, Katsumi

    2000-01-01

    Evaluation of image quality and medical exposure dose is very important in mammography. However, the standard compressed breast thickness of Japanese women is uncertain. Authors therefore analyzed compressed breast thickness on bilateral cephalocaudal and mediolateral oblique radiographs of 3445 women who underwent mammography between June 5, 1989 and December 7, 1998. The total average compressed breast thickness was about 10 mm less than the thickness of the American College of Radiography (ACR) standard mammographic accreditation phantom. It therefore appears necessary to establish a Japanese standard for the phantom to evaluate image quality and medical exposure dose accurately in Japanese women. (K.H.)

  1. Continuous thickness control of extruded pipes with assistance of microcomputers

    International Nuclear Information System (INIS)

    Breil, J.

    1983-06-01

    Because of economic and quality securing reasons a constant wall thickness of extruded pipes in circumference and extrusion direction is an important production aim. Therefore a microcomputer controlled system was developed, which controls die centering with electric motors. The control of wall thickness distribution; was realized with two conceptions: a dead time subjected control with a rotating on line wall thickness measuring instrument and an adaptive control with sensors in the pipe die. With a PI-algorithm excentricities of 30% of the wall thickness could be controlled below a trigger level of 2% within three dead times. (orig.) [de

  2. Stresses and strains in thick perforated orthotropic plates

    Science.gov (United States)

    A. Alshaya; John Hunt; R. Rowlands

    2016-01-01

    Stress and strain concentrations and in-plane and out-of-plane stress constraint factors associated with a circular hole in thick, loaded orthotropic composite plates are determined by three-dimensional finite element method. The plate has essentially infinite in-plane geometry but finite thickness. Results for Sitka Spruce wood are emphasized, although some for carbon...

  3. METALLICITY GRADIENTS OF THICK DISK DWARF STARS

    Energy Technology Data Exchange (ETDEWEB)

    Carrell, Kenneth; Chen Yuqin; Zhao Gang, E-mail: carrell@nao.cas.cn [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2012-12-01

    We examine the metallicity distribution of the Galactic thick disk using F, G, and K dwarf stars selected from the Sloan Digital Sky Survey, Data Release 8. Using the large sample of dwarf stars with proper motions and spectroscopically determined stellar parameters, metallicity gradients in the radial direction for various heights above the Galactic plane and in the vertical direction for various radial distances from the Galaxy center have been found. In particular, we find a vertical metallicity gradient of -0.113 {+-} 0.010 (-0.125 {+-} 0.008) dex kpc{sup -1} using an isochrone (photometric) distance determination in the range 1 kpc <|Z| < 3 kpc, which is the vertical height range most consistent with the thick disk of our Galaxy. In the radial direction, we find metallicity gradients between +0.02 and +0.03 dex kpc{sup -1} for bins in the vertical direction between 1 kpc <|Z| < 3 kpc. Both of these results agree with similar values determined from other populations of stars, but this is the first time a radial metallicity gradient for the thick disk has been found at these vertical heights. We are also able to separate thin and thick disk stars based on kinematic and spatial probabilities in the vertical height range where there is significant overlap of these two populations. This should aid further studies of the metallicity gradients of the disk for vertical heights lower than those studied here but above the solar neighborhood. Metallicity gradients in the thin and thick disks are important probes into possible formation scenarios for our Galaxy and a consistent picture is beginning to emerge from results using large spectroscopic surveys, such as the ones presented here.

  4. Thick Galactic Cosmic Radiation Shielding Using Atmospheric Data

    Science.gov (United States)

    Youngquist, Robert C.; Nurge, Mark A.; Starr, Stanley O.; Koontz, Steven L.

    2013-01-01

    NASA is concerned with protecting astronauts from the effects of galactic cosmic radiation and has expended substantial effort in the development of computer models to predict the shielding obtained from various materials. However, these models were only developed for shields up to about 120 g!cm2 in thickness and have predicted that shields of this thickness are insufficient to provide adequate protection for extended deep space flights. Consequently, effort is underway to extend the range of these models to thicker shields and experimental data is required to help confirm the resulting code. In this paper empirically obtained effective dose measurements from aircraft flights in the atmosphere are used to obtain the radiation shielding function of the earth's atmosphere, a very thick shield. Obtaining this result required solving an inverse problem and the method for solving it is presented. The results are shown to be in agreement with current code in the ranges where they overlap. These results are then checked and used to predict the radiation dosage under thick shields such as planetary regolith and the atmosphere of Venus.

  5. Development of sea water pipe thickness measurement technique

    International Nuclear Information System (INIS)

    Morimoto, Kazuo; Wakayama, Seiichi; Takeuchi, Iwao; Masamori, Sigero; Yamasita, Takesi.

    1995-01-01

    In nuclear and thermal power plants, wall wear of sea water pipes is reported to occur in the inner surface due to corrosion and erosion. From the viewpoint of improving the equipments reliability, it is desirable that wall thickness should be measured from the outer surface of the pipe during operation. In the conventional method, paint on the outer surface of the pipe was locally removed at each point of a 20 by 50 mm grid, and inspection was carried out at these spots. However, this method had some problems, such as (1) it was necessary to replace the paint, and (2) it was difficult to obtain the precise distribution of wall thickness. Therefore, we have developed a wall thickness measuring system which has the following features. (1) It is possible to perform inspection from the outer surface without removing paint during operation. (2) It is possible to measure the distribution of wall thickness and display it as color contour map simultaneously. (3) The work of inspectors can be alleviated by the automatic recording of measured data. (author)

  6. Overweight is not associated with cortical thickness alterations in children

    Directory of Open Access Journals (Sweden)

    Rachel Jane Sharkey

    2015-02-01

    Full Text Available IntroductionSeveral studies report an association between body mass index (BMI and cortical thickness in adults. Some studies demonstrate diffuse cortical thinning in obesity, while others report effects in areas that are associated with self-regulation, such as lateral prefrontal cortex. MethodsThis study used multilevel modelling of data from the NIH Pediatric MRI Data Repository, a mixed longitudinal and cross-sectional database, to examine the relationship between cortical thickness and body weight in children. Cortical thickness was computed at 81,942 vertices of 716 MRI scans from 378 children aged between 4 and 18 years. Body mass index Z score for age was computed for each participant. We preformed vertex-wise statistical analysis of the relationship between cortical thickness and BMI, accounting for age and gender. In addition, cortical thickness was extracted from regions of interest in prefrontal cortex and insula.ResultsNo significant association between cortical thickness and BMI was found, either by statistical parametric mapping or by region of interest analysis. Results remained negative when the analysis was restricted to children aged 12-18.ConclusionsThe correlation between BMI and cortical thickness was not found in this large pediatric sample. The association between BMI and cortical thinning develops after adolescence. This has implications for the nature of the relationship between brain anatomy and weight gain.

  7. Determination of material and its thickness for Cs-137 gamma source shielding

    International Nuclear Information System (INIS)

    Tukiman

    2008-01-01

    Its has been determined the shielding material and its thickness necessarily conducted due to every material will have different half-thickness characteristics, and by the selection a suitable material and its thickness will be obtained. Half-thickness of any material is the ability of the material at a certain thickness to absorb any radiation intensity so that the intensity becomes half of its source. Sample materials to be used are concrete, wood, and lead with their thickness varied. From experiment data and theoretical computation can be concluded that lead is the suitable material for shielding with the value of HVT for gamma radiation 0,732 cm. For wood and concrete will give half-thickness of 11,0 cm and 3,164 cm respectively. (author)

  8. The reports of thick discs' deaths are greatly exaggerated. Thick discs are NOT artefacts caused by diffuse scattered light

    Science.gov (United States)

    Comerón, S.; Salo, H.; Knapen, J. H.

    2018-02-01

    Recent studies have made the community aware of the importance of accounting for scattered light when examining low-surface-brightness galaxy features such as thick discs. In our past studies of the thick discs of edge-on galaxies in the Spitzer Survey of Stellar Structure in Galaxies - the S4G - we modelled the point spread function as a Gaussian. In this paper we re-examine our results using a revised point spread function model that accounts for extended wings out to more than 2\\farcm5. We study the 3.6 μm images of 141 edge-on galaxies from the S4G and its early-type galaxy extension. Thus, we more than double the samples examined in our past studies. We decompose the surface-brightness profiles of the galaxies perpendicular to their mid-planes assuming that discs are made of two stellar discs in hydrostatic equilibrium. We decompose the axial surface-brightness profiles of galaxies to model the central mass concentration - described by a Sérsic function - and the disc - described by a broken exponential disc seen edge-on. Our improved treatment fully confirms the ubiquitous occurrence of thick discs. The main difference between our current fits and those presented in our previous papers is that now the scattered light from the thin disc dominates the surface brightness at levels below μ 26 mag arcsec-2. We stress that those extended thin disc tails are not physical, but pure scattered light. This change, however, does not drastically affect any of our previously presented results: 1) Thick discs are nearly ubiquitous. They are not an artefact caused by scattered light as has been suggested elsewhere. 2) Thick discs have masses comparable to those of thin discs in low-mass galaxies - with circular velocities vc< 120 km s-1 - whereas they are typically less massive than the thin discs in high-mass galaxies. 3) Thick discs and central mass concentrations seem to have formed at the same epoch from a common material reservoir. 4) Approximately 50% of the up

  9. The correlation between plantar fascia thickness and symptoms of plantar fasciitis.

    Science.gov (United States)

    Mahowald, Sarah; Legge, Bradford S; Grady, John F

    2011-01-01

    The purpose of this study was to determine whether changes in plantar fascia thickness are a reliable gauge of efficacy of treatment protocols for plantar fasciitis. Thirty-nine feet (30 patients) with plantar fasciitis received an ultrasound examination to measure the thickness of the medial band of the plantar fascia. Each patient assessed his or her pain using the visual analogue scale. Following various treatments, a second ultrasound examination was performed and the thickness of the plantar fascia was again measured and subjective pain level assessed. Twenty-nine feet (74.4%) showed a decrease in plantar fascia thickness and a decrease in pain. One foot (2.6%) experienced an increase in fascia thickness and reported an increase in pain. Four feet (10.3%) had an increase in thickness of the plantar fascia and reported no change in pain level. Three feet had minor increases in fascia thickness but reported a decrease in pain (7.7%). One foot (2.6%) had no change in fascia thickness but a decrease in pain and one foot (2.6%) had a decrease in the plantar fascia but no change in pain level. The average reduction in fascia thickness was 0.82 mm ± 1.04 mm, correlating with an average improvement in pain of 3.64 ± 2.7 (P plantar fascia is a valid objective measurement to assess effectiveness of new or existing treatment protocols.

  10. Quantitative materials analysis of micro devices using absorption-based thickness measurements

    International Nuclear Information System (INIS)

    Sim, L M; Wog, B S; Spowage, A C

    2006-01-01

    Preliminary work in designing an X-ray inspection machine with the capability of providing quantitative thickness analysis based on absorption measurements has been demonstrated. This study attempts to use the gray levels data to investigate the nature and thickness of occluded features and materials within devices. The investigation focused on metallic materials essential to semiconductor and MEMS technologies such as tin, aluminium, copper, silver, iron and zinc. The materials were arranged to simulate different feature thicknesses and sample geometries. The X-ray parameters were varied in-order to modify the X-ray energy spectrum with the aim of optimising the measurement conditions for each sample. The capability of the method to resolve differences in thicknesses was found to be highly dependent on the material. The thickness resolution with aluminium was the poorest due to its low radiographic density. The thickness resolutions achievable for silver and tin were significantly better and of the order of 0.015 mm and 0.025 mm respectively. From the linear relationship between the X-ray attenuation and sample thickness established, the energy dependent linear attenuation coefficient for each material was determined for a series of specific energy spectra. A decrease in the linear attenuation coefficient was observed as the applied voltage and thickness of the material increased. The results provide a platform for the development of a novel absorption-based thickness measurement system that can be optimised for a range of industrial applications

  11. High interannual variability of sea ice thickness in the Arctic region.

    Science.gov (United States)

    Laxon, Seymour; Peacock, Neil; Smith, Doug

    2003-10-30

    Possible future changes in Arctic sea ice cover and thickness, and consequent changes in the ice-albedo feedback, represent one of the largest uncertainties in the prediction of future temperature rise. Knowledge of the natural variability of sea ice thickness is therefore critical for its representation in global climate models. Numerical simulations suggest that Arctic ice thickness varies primarily on decadal timescales owing to changes in wind and ocean stresses on the ice, but observations have been unable to provide a synoptic view of sea ice thickness, which is required to validate the model results. Here we use an eight-year time-series of Arctic ice thickness, derived from satellite altimeter measurements of ice freeboard, to determine the mean thickness field and its variability from 65 degrees N to 81.5 degrees N. Our data reveal a high-frequency interannual variability in mean Arctic ice thickness that is dominated by changes in the amount of summer melt, rather than by changes in circulation. Our results suggest that a continued increase in melt season length would lead to further thinning of Arctic sea ice.

  12. Manual for target thickness measurement by alpha particle irradiation

    International Nuclear Information System (INIS)

    Dias, J.F.; Martins, M.N.

    1990-04-01

    A system is described for thin-target thickness measurement through the alpha particle energy loss when them traverse the target. It is also described the program used in the analysis of the target thickness. (L.C.) [pt

  13. Choroidal thickness in Chinese patients with non-arteritic anterior ischemic optic neuropathy.

    Science.gov (United States)

    Jiang, Libin; Chen, Lanlan; Qiu, Xiujuan; Jiang, Ran; Wang, Yaxing; Xu, Liang; Lai, Timothy Y Y

    2016-08-31

    Non-arteritic anterior ischemic optic neuropathy (NA-AION) is one of the most common types of ischemic optic neuropathy. Several recent studies suggested that abnormalities of choroidal thickness might be associated with NA-AION. The main objective of this case-control study was to evaluate whether choroidal thickness is an ocular risk factor for the development of NA-AION by evaluating the peripapillary and subfoveal choroidal thicknesses in affected Chinese patients. Forty-four Chinese patients with unilateral NA-AION were recruited and compared with 60 eyes of 60 normal age and refractive-error matched control subjects. Peripapillary and subfoveal choroidal thicknesses were measured by enhanced depth imaging optical coherence tomography. Choroidal thicknesses of eyes with NA-AION and unaffected fellow eyes were compared with normal controls. Choroidal thicknesses of NA-AION eyes with or without optic disc edema were also compared. The correlation between choroidal thickness and retinal nerve fiber layer (RNFL) thickness, logMAR best-corrected visual acuity (BCVA), and the mean deviation (MD) of Humphrey static perimetry in NA-AION eyes were analyzed. The peripapillary choroidal thicknesses at the nasal, nasal inferior and temporal inferior segments in NA-AION eyes with optic disc edema were significantly thicker compared with that of normal subjects (P optic disc edema and normal eyes (all P > 0.05). No significant correlation between choroidal thickness and RNFL thickness, logMAR BCVA and perimetry MD was found in eyes affected by NA-AION (all P > 0.05). Increase in peripapillary choroid thickness in some segments was found in NA-ION eyes with optic disc edema. However, our findings do not support the hypothesis that choroidal thickness is abnormal in Chinese patients with NA-AION compared with normal subjects with similar age and refractive error status.

  14. Effect of length to thickness ratio on free vibration analysis of thick fiber reinforced plastic skew cross-ply laminate with circular cutout

    Science.gov (United States)

    Srividya, K.; Reddy, Ch. Kishore; Sumanth, Ch. Mohan; Krishnaiah, P. Gopala; Kishan, V. Mallikharjuna

    2018-04-01

    The present investigation deals with the free vibration analysis of a thick four-layered symmetric cross-ply skew laminated composite plate with a circular cutout. Three dimensional finite element models (FEM) which use the elasticity theory for the determination of stiffness matrices are modeled in ANSYS software to evaluate first five natural frequencies of the laminate. The variations of the first five natural frequencies with respect to length to thickness ratio (S) for different diameter to length ratios (d/l) are presented. It is observed that, the natural frequencies decreases with increase of thickness ratio(S).

  15. Estimation of creep life of thick welded joints using a simple model. Creep characteristics in thick welded joint and their improvements. 2

    International Nuclear Information System (INIS)

    Nakacho, Keiji; Yamazaki, Masayoshi

    2001-01-01

    The information of the creep behavior of the thick welded joint is very important to secure the safety of the elevated temperature vessels like the nuclear reactors. The creep behavior of the thick welded point is very complex, thence it is difficult to practice the experiment or the theoretical analysis. A simple accurate model for theoretical analysis was developed in the first study. The simple model is constructed of several one-dimensional finite elements which can analyze three-dimensional creep behavior under a assumption. The model is easy to treat, and needs only a little labor and computation time to simulate the creep curve and local strain of the thick welded joint. In this second study, the capability of the model is expanded to estimate the creep life of the thick welded joint. New model can easily estimate the time of the rupture of the thick welded joint. It is verified comparing the result with the experimental one that the model can accurately predict the creep life. The histories of the local strains to the rupture time may be observed in the simulation by using the model. The information will be useful to improve the creep characteristics of the joints. (author)

  16. Enamel thickness after preparation of tooth for porcelain laminate.

    Science.gov (United States)

    Pahlevan, Ayoub; Mirzaee, Mansoreh; Yassine, Esmaeil; Ranjbar Omrany, Ladan; Hasani Tabatabaee, Masumeh; Kermanshah, Hamid; Arami, Sakineh; Abbasi, Mehdy

    2014-07-01

    In this investigation the thickness of enamel in the gingival, middle, and incisal thirds of the labial surface of the anterior teeth were measured regarding preparation of the teeth for porcelain laminate veneers. Part one, 20 extracted intact human maxillary central and lateral incisors ten of each were selected. The teeth were imbedded in autopolimerize acrylic resin. Cross section was preformed through the midline of the incisal, middle and cervical one-third of the labial surface of the teeth. The samples were observed under reflected stereomicroscope and the thickness of enamel was recorded. Part II, the effect of different types of preparation on dentin exposure was evaluated. Thirty maxillary central incisor teeth were randomly divided into two groups: A: Knife-edge preparation. B: Chamfer preparation. All samples were embedded in autopolimerize acrylic resin using a silicon mold. The samples were cut through the midline of the teeth. The surface of the samples were polished and enamel and dentin were observed under the stereomicroscope. Data were analyzed by ANOVA-one way test. The results of this study showed that the least enamel thickness in the central incisor was 345 and in lateral incisor is 235 μ this thickness is related to the one-third labial cervical area. Maximum thickness in maxillary central and lateral incisors in the one-third labial incisal surface was 1260 μ and 1220μ, respectively. In the second part of the study, the tendency of dentinal exposure was shown with the chamfer preparation, but no dentinal exposure was found in the knife-edge preparation. The differences between groups were significant (p<0.05). The knowledge of enamel thickness in different part of labial surface is very important. The thickness of enamel in the gingival area does not permit a chamfer preparation. The knife edge preparation is preferable in gingival area.

  17. Enamel thickness after preparation of tooth for porcelain laminate.

    Directory of Open Access Journals (Sweden)

    Ayoub Pahlevan

    2014-08-01

    Full Text Available In this investigation the thickness of enamel in the gingival, middle, and incisal thirds of the labial surface of the anterior teeth were measured regarding preparation of the teeth for porcelain laminate veneers.Part one, 20 extracted intact human maxillary central and lateral incisors ten of each were selected. The teeth were imbedded in autopolimerize acrylic resin. Cross section was preformed through the midline of the incisal, middle and cervical one-third of the labial surface of the teeth. The samples were observed under reflected stereomicroscope and the thickness of enamel was recorded. Part II, the effect of different types of preparation on dentin exposure was evaluated. Thirty maxillary central incisor teeth were randomly divided into two groups: A: Knife-edge preparation. B: Chamfer preparation. All samples were embedded in autopolimerize acrylic resin using a silicon mold. The samples were cut through the midline of the teeth. The surface of the samples were polished and enamel and dentin were observed under the stereomicroscope.Data were analyzed by ANOVA-one way test. The results of this study showed that the least enamel thickness in the central incisor was 345 and in lateral incisor is 235 μ this thickness is related to the one-third labial cervical area. Maximum thickness in maxillary central and lateral incisors in the one-third labial incisal surface was 1260 μ and 1220μ, respectively. In the second part of the study, the tendency of dentinal exposure was shown with the chamfer preparation, but no dentinal exposure was found in the knife-edge preparation. The differences between groups were significant (p<0.05.The knowledge of enamel thickness in different part of labial surface is very important. The thickness of enamel in the gingival area does not permit a chamfer preparation. The knife edge preparation is preferable in gingival area.

  18. Effects of thickness and surface roughness on mechanical properties of aluminum sheets

    International Nuclear Information System (INIS)

    Suh, Chang Hee; Jung, Yun Chul; Kim, Young Suk

    2010-01-01

    The effect of thickness on the mechanical properties of Al 6K21-T4 sheet specimens under uniaxial tension was investigated. In order to reduce the thickness of the specimens without changing the microstructure and grain size, chemical etching was carried out, resulting in Al sheets ranging from 0.40 mm to 1.58 mm in thickness. Additionally, the effect of surface roughness was determined by finite element (FE) calculations performed using FE code MARC 2007. Tensile specimens of varying surface roughness were modeled and simulated. An analysis of the combined effects of the thickness and surface roughness revealed that the yield and tensile strengths decreased when the number of grains over the thickness was decreased. The ductility also decreased when reducing the thickness. An FE simulation showed that both the surface roughness and thickness affected the flow-curve shape. Moreover, the effect of the surface roughness tended to increase when decreasing the sheet thickness of specimens having the same roughness

  19. Smoking influences on the thickness of marginal gingival epithelium

    Directory of Open Access Journals (Sweden)

    Villar Cristina Cunha

    2003-01-01

    Full Text Available Smoking patients show reduction of inflammatory clinical signs that might be associated with local vasoconstriction and an increased gingival epithelial thickness. The purpose of this work was to evaluate the thickness of the marginal gingival oral epithelium in smokers and non-smokers, with clinically healthy gingivae or with gingivitis. Twenty biopsies were obtained from four different groups. Group I: non-smokers with clinically healthy gingivae (n = 5. Group II: non-smokers with gingivitis (n = 5. Group III: smokers with clinically healthy gingivae (n = 5. Group IV: smokers with gingivitis (n = 5. These biopsies were histologically processed, serially sectioned at 5 mm, stained with H. E., and examined by image analysis software (KS400, which was used to perform the morphometric evaluation and the quantification of the major epithelial thickness, the epithelial base thickness and the external and internal epithelial perimeters. Differences between the four groups were analyzed using ANOVA test and Tukey's test. The criteria for statistical significance were accepted at the probability level p < 0.05. A greater epithelial thickness was observed in smokers independent of the gingival health situation.

  20. Enface Thickness Mapping and Reflectance Imaging of Retinal Layers in Diabetic Retinopathy.

    Science.gov (United States)

    Francis, Andrew W; Wanek, Justin; Lim, Jennifer I; Shahidi, Mahnaz

    2015-01-01

    To present a method for image segmentation and generation of enface thickness maps and reflectance images of retinal layers in healthy and diabetic retinopathy (DR) subjects. High density spectral domain optical coherence tomography (SDOCT) images were acquired in 10 healthy and 4 DR subjects. Customized image analysis software identified 5 retinal cell layer interfaces and generated thickness maps and reflectance images of the total retina (TR), inner retina (IR), outer retina (OR), and the inner segment ellipsoid (ISe) band. Thickness maps in DR subjects were compared to those of healthy subjects by generating deviation maps which displayed retinal locations with thickness below, within, and above the normal 95% confidence interval. In healthy subjects, TR and IR thickness maps displayed the foveal depression and increased thickness in the parafoveal region. OR and ISe thickness maps showed increased thickness at the fovea, consistent with normal retinal anatomy. In DR subjects, thickening and thinning in localized regions were demonstrated on TR, IR, OR, and ISe thickness maps, corresponding to retinal edema and atrophy, respectively. TR and OR reflectance images showed reduced reflectivity in regions of increased thickness. Hard exudates appeared as hyper-reflective spots in IR reflectance images and casted shadows on the deeper OR and ISe reflectance images. The ISe reflectance image clearly showed the presence of focal laser scars. Enface thickness mapping and reflectance imaging of retinal layers is a potentially useful method for quantifying the spatial and axial extent of pathologies due to DR.

  1. Terahertz Mapping of Microstructure and Thickness Variations

    Science.gov (United States)

    Roth, Donald J.; Seebo, Jeffrey P.; Winfree, William P.

    2010-01-01

    A noncontact method has been devised for mapping or imaging spatial variations in the thickness and microstructure of a layer of a dielectric material. The method involves (1) placement of the dielectric material on a metal substrate, (2) through-the-thickness pulse-echo measurements by use of electromagnetic waves in the terahertz frequency range with a raster scan in a plane parallel to the substrate surface that do not require coupling of any kind, and (3) appropriate processing of the digitized measurement data.

  2. Development of examination technique for oxide layer thickness measurement of irradiated fuel rods

    International Nuclear Information System (INIS)

    Koo, D. S.; Park, S. W.; Kim, J. H.; Seo, H. S.; Min, D. K.; Kim, E. K.; Chun, Y. B.; Bang, K. S.

    1999-06-01

    Technique for oxide layer thickness measurement of irradiated fuel rods was developed to measure oxide layer thickness and study characteristic of fuel rods. Oxide layer thickness of irradiated fuels were measured, analyzed. Outer oxide layer thickness of 3 cycle-irradiated fuel rods were 20 - 30 μm, inner oxide layer thickness 0 - 10 μm and inner oxide layer thickness on cracked cladding about 30 μm. Oxide layer thickness of 4 cycle-irradiated fuel rods were about 2 times as thick as those of 1 cycle-irradiated fuel rods. Oxide layer on lower region of irradiated fuel rods was thin and oxide layer from lower region to upper region indicated gradual increase in thickness. Oxide layer thickness from 2500 to 3000 mm showed maximum and oxide layer thickness from 3000 to top region of irradiated fuel rods showed decreasing trend. Inner oxide layer thicknesses of 4 cycle-irradiated fuel rod were about 8 μm at 750 - 3500 mm from the bottom end of fuel rod. Outer oxide layer thickness were about 8 μm at 750 - 1000 mm from the bottom end of fuel rod. These indicated gradual increase up to upper region from the bottom end of fuel rod. These indicated gradual increase up to upper region from the bottom end of fuel. Oxide layer thickness technique will apply safety evaluation and study of reactor fuels. (author). 6 refs., 14 figs

  3. Anthropometric record to be used in Centers for Family Health Support: possibilities and obstacles

    Directory of Open Access Journals (Sweden)

    Camila Fabiana Rossi Squarcini

    2015-02-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2015v17n2p248   A model of an anthropometric record to be used in the Núcleos de Apoio à Saúde da Família (Centers for Family Health Support in Brazil has been proposed in the literature, showing the logistics of use. The aim of this study was to discuss the anthropometric record, showing the potential and obstacles of its use. It was observed that, for adults, the screening measures (body mass index and waist circumference for the determination of the risk of cardiovascular and metabolic diseases can be considered promising, although the Basic Health Care network already uses these measures. Nevertheless, the supplementary assessment (skinfold thickness and body circumferences could be another potential possibility, except for the time spent to perform this assessment and the lack of studies of the cost-benefit of these anthropometric techniques. It was concluded that the anthropometric record proposed is an important instrument for improving the quality of the service provided to users of the Basic Health Care System; however, some adjustments, such as the removal of skinfold measurements as part of primary care, should be taken into consideration.

  4. Nutritional status and body composition of inpatients: the effects of nutritional transition

    Directory of Open Access Journals (Sweden)

    Kátia Cristina Portero-McLellan

    2010-03-01

    Full Text Available Objectives: To investigate the effects of nutritional transition on the nutritional status and body composition of inpatients. Methods: We assessed 819 inpatients (435 men and 384women regarding clinical, anthropometric and dietary aspects. The anthropometric variables studied were: current weight (CW, height (H, waist circumference (WC, hip circumference (HC, arm circumference (AC, triceps skinfold (TSF and subscapular skinfold thickness (SST. From these measures were determined: the body mass index (BMI, the waist and hip ratio (WHR, the waist and height ratio (RCA, the arm muscle circumference (AMC, the arm muscle area (AMA and arm fat area (AFA. For the diagnosis of central adiposity, we used the relationship between waist and hip circumferences. Results: The mean age was 53.7 ± 16.0 years, with hospital stay of 8 days, being higher among the elderly (p <0.01. Most patients (47.8% were overweight or obese, 48.6% presented altered values of waist circumference and 76.4% had central adiposity. Cardiovascular disease accounted for 45.4% of total admissions, and 60.4% among the elderly. Conclusion: This study showed high prevalence of obesity and central adiposity among inpatients regardless of gender, age, and the reason for admission, evidencing the effects of nutritional transition in the studied population.

  5. What is associated with race performance in male 100-km ultra-marathoners--anthropometry, training or marathon best time?

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas; Senn, Oliver

    2011-03-01

    We investigated the associations of anthropometry, training, and pre-race experience with race time in 93 recreational male ultra-marathoners (mean age 44.6 years, s = 10.0; body mass 74.0 kg, s = 9.0; height 1.77 m, s = 0.06; body mass index 23.4 kg · m(-2), s = 2.0) in a 100-km ultra-marathon using bivariate and multivariate analysis. In the bivariate analysis, body mass index (r = 0.24), the sum of eight skinfolds (r = 0.55), percent body fat (r = 0.57), weekly running hours (r = -0.29), weekly running kilometres (r = -0.49), running speed during training (r = -0.50), and personal best time in a marathon (r = 0.72) were associated with race time. Results of the multiple regression analysis revealed an independent and negative association of weekly running kilometres and average speed in training with race time, as well as a significant positive association between the sum of eight skinfold thicknesses and race time. There was a significant positive association between 100-km race time and personal best time in a marathon. We conclude that both training and anthropometry were independently associated with race performance. These characteristics remained relevant even when controlling for personal best time in a marathon.

  6. Kinanthropometric and performance characteristics of elite and non-elite female softball players.

    Science.gov (United States)

    Singh, S; Singh, M; Rathi, B

    2013-12-01

    The purpose of the present study was to compare the kinanthropometric and performance characteristics of elite and non-elite female softball players. A total forty elite and non-elite level female softball players were selected from the different colleges affiliated to the Guru Nanak Dev University, Amritsar, for the present study. The height of subjects was measured by using the standard anthropometric rod. Weight was measured with portable weighing machine. Widths and diameters of body parts were measured by using digital caliper. Girths and lengths were taken with steel tape. Skinfold thickness measurements were taken using the Slimguide skinfold caliper. All subjects were also assessed for performance tests i.e. vertical jump, 50m sprint, medicine ball throw, 10×4m shuttle run and reaction time. Independent samples t-test reveals that elite female softball players were significantly taller (Psoftball players also had significantly greater biacromial (Psoftball players. The non-elite female softball players were found to have significantly greater thigh circumference (Psoftball players. The non-elite players were also found to have significantly higher percentage body fat (Psoftball players. The elite female softball players had significantly greater kinanthropometric characteristics, body composition and performance characteristics than the non-elite female softball players.

  7. Ultrasonographic study of gallbladder wall thickness in acute viral hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jin Sook; Kim, Kyung Jung; Park, Yang Hee; Kang, Ik Won; Yoon, Jong Sup [Hanyang Sacred Heart Hospital, Hallym University Medical Center, Seoul (Korea, Republic of)

    1984-09-15

    Prospective study of gallbladder wall thickness by ultrasonography was performed in 38 patients of acute viral hepatitis and 50 normal subjects as a control group from June 1983 to April 1984. The results were as follows; 1. In normal population, the range of gallbladder wall thickness is from 1 mm to 3 mm with peak incidence in 2 mm (66%, 33 case). Mean thickness of gallbladder wall is about 1.9 {+-} 0.6 mm. 2. In acute viral hepatitis, the range of gallbladder wall thickness is from 2 mm to 8 mm with peak incidence in 3 mm (34%, 13 case), second peak in 4 mm (29%, 11 case). Mean thickness of gallbladder wall is about 3.6 {+-} 1.6 mm, which is thicker than normal with statistical significance. (p<0.005) 3. In acute viral hepatitis, the mean thickness of gallbladder wall is about 4.4 {+-} 1.8 mm in the group of SGOT/SGPT level above 400 IU, and 2.8 {+-} 0.8 mm in the group of SGOT/ SGPT level below 400 IU. This difference is significant statistically. (p<0.05)

  8. Ultrasonographic study of gallbladder wall thickness in acute viral hepatitis

    International Nuclear Information System (INIS)

    Lim, Jin Sook; Kim, Kyung Jung; Park, Yang Hee; Kang, Ik Won; Yoon, Jong Sup

    1984-01-01

    Prospective study of gallbladder wall thickness by ultrasonography was performed in 38 patients of acute viral hepatitis and 50 normal subjects as a control group from June 1983 to April 1984. The results were as follows; 1. In normal population, the range of gallbladder wall thickness is from 1 mm to 3 mm with peak incidence in 2 mm (66%, 33 case). Mean thickness of gallbladder wall is about 1.9 ± 0.6 mm. 2. In acute viral hepatitis, the range of gallbladder wall thickness is from 2 mm to 8 mm with peak incidence in 3 mm (34%, 13 case), second peak in 4 mm (29%, 11 case). Mean thickness of gallbladder wall is about 3.6 ± 1.6 mm, which is thicker than normal with statistical significance. (p<0.005) 3. In acute viral hepatitis, the mean thickness of gallbladder wall is about 4.4 ± 1.8 mm in the group of SGOT/SGPT level above 400 IU, and 2.8 ± 0.8 mm in the group of SGOT/ SGPT level below 400 IU. This difference is significant statistically. (p<0.05)

  9. Application of generalized function to dynamic analysis of thick plates

    International Nuclear Information System (INIS)

    Zheng, D.; Weng, Z.

    1987-01-01

    The structures with thick plates have been used extensively in national defence, mechanical engineering, chemical engineering, nuclear engineering, civil engineering, etc.. Various theories have been established to deal with the problems of elastic plates, which include the classical theory of thin plates, the improved theory of thick plates, three-dimensional elastical theory. In this paper, the derivative of δ-function is handled by using the generalized function. The dynamic analysis of thick plates subjected the concentrated load is presented. The improved Donnell's equation of thick plates is deduced and employed as the basic equation. The generalized coordinates are solved by using the method of MWR. The general expressions for the dynamic response of elastic thick plates subjected the concentrated load are given. The numerical results for rectangular plates are given herein. The results are compared with those obtained from the improved theory and the classical theory of plates. (orig./GL)

  10. Eggshell thickness variation in red-legged partridge (Alectoris rufa) from Spain

    DEFF Research Database (Denmark)

    Castilla, Aurora M.; de Aragón, Juan Martínez; Herrel, Anthony

    2009-01-01

    Eggshell thickness is commonly used as an indicator of habitat quality and effects of environmental pollution on avian reproduction. We present the first data available on eggshell thickness for Red-legged Partridge (Alectoris rufa) in Spain. We compared eggshell thickness between eggs collected...

  11. The relation between sea ice thickness and freeboard in the Arctic

    Directory of Open Access Journals (Sweden)

    V. Alexandrov

    2010-09-01

    Full Text Available Retrieval of Arctic sea ice thickness from CryoSat-2 radar altimeter freeboard data requires observational data to verify the relation between these two variables. In this study in-situ ice and snow data from 689 observation sites, obtained during the Sever expeditions in the 1980s, have been used to establish an empirical relation between thickness and freeboard of FY ice in late winter. Estimates of mean and variability of snow depth, snow density and ice density were produced on the basis of many field observations. These estimates have been used in the hydrostatic equilibrium equation to retrieve ice thickness as a function of ice freeboard, snow depth and snow/ice density. The accuracy of the ice thickness retrieval has been calculated from the estimated variability in ice and snow parameters and error of ice freeboard measurements. It is found that uncertainties of ice density and freeboard are the major sources of error in ice thickness calculation. For FY ice, retrieval of ≈ 1.0 m (2.0 m thickness has an uncertainty of 46% (37%, and for MY ice, retrieval of 2.4 m (3.0 m thickness has an uncertainty of 20% (18%, assuming that the freeboard error is ± 0.03 m for both ice types. For MY ice the main uncertainty is ice density error, since the freeboard error is relatively smaller than that for FY ice. If the freeboard error can be reduced to 0.01 m by averaging measurements from CryoSat-2, the error in thickness retrieval is reduced to about 32% for a 1.0 m thick FY floe and to about 18% for a 2.4 m thick MY floe. The remaining error is dominated by uncertainty in ice density. Provision of improved ice density data is therefore important for accurate retrieval of ice thickness from CryoSat-2 data.

  12. Comparison of Simulated PEC Probe Performance for Detecting Wall Thickness Reduction

    International Nuclear Information System (INIS)

    Shin, Young Kil; Choi, Dong Myung; Jung, Hee Sung

    2009-01-01

    In this paper, four different types of pulsed eddy current(PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction can be achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.

  13. A new attempt of measurement film thickness by x-ray diffractometry

    International Nuclear Information System (INIS)

    Kosaka, Masao; Kobayashi, Hideo

    1987-01-01

    In order to make film thickness measurements independent from the property or the structure of the film materials or the substrate, it is needed to adopt instead of directly utilizing the X-ray diffraction intensity, or attenuation information obtained from the substrate or film material, other new methods for measurement. Among the information obtained by X-ray diffraction, if intensity is excluded, others are F.W.H.M. and diffraction angle, only. If it is possible to investigate the film thickness dependency of the diffraction angle, it should be possible to measure the film thickness by diffraction angle. However, since diffraction angle has no film thickness dependency, it cannot be used directly for measurement. However, if we consider the principle of the X-ray diffractometer method, although it may be very slight, the substrate will be eccentric from the revolving center of the goniometer on account of the thickness of the film. If eccentricity occurs, this will cause changes in the diffraction angle. If we set the radius of the goniometer as R, diffraction angle θ, and the eccentricity from the revolving center of the specimen surface X, the deflection angle Δ2θ of 2θ may be expressed by Δ2θ = -2X · COSθ/R Thus, if X is caused by the film thickness, and by measuring the Δ2θ, it will be possible to measure the film thickness. As a result of the experiment, it was found that X-ray diffraction method can be used for the measurement of the film thickness of a few microns or above by utilizing the eccentricity caused by the film thickness. Especially it has the advantage of being able to measure thick films that X-rays will not penetrate, without being influenced by the chemical structure of the film or the substrates. (author)

  14. Dendritic thickness: a morphometric parameter to classify mouse retinal ganglion cells

    Directory of Open Access Journals (Sweden)

    L.D. Loopuijt

    2007-10-01

    Full Text Available To study the dendritic morphology of retinal ganglion cells in wild-type mice we intracellularly injected these cells with Lucifer yellow in an in vitro preparation of the retina. Subsequently, quantified values of dendritic thickness, number of branching points and level of stratification of 73 Lucifer yellow-filled ganglion cells were analyzed by statistical methods, resulting in a classification into 9 groups. The variables dendritic thickness, number of branching points per cell and level of stratification were independent of each other. Number of branching points and level of stratification were independent of eccentricity, whereas dendritic thickness was positively dependent (r = 0.37 on it. The frequency distribution of dendritic thickness tended to be multimodal, indicating the presence of at least two cell populations composed of neurons with dendritic diameters either smaller or larger than 1.8 µm ("thin" or "thick" dendrites, respectively. Three cells (4.5% were bistratified, having thick dendrites, and the others (95.5% were monostratified. Using k-means cluster analysis, monostratified cells with either thin or thick dendrites were further subdivided according to level of stratification and number of branching points: cells with thin dendrites were divided into 2 groups with outer stratification (0-40% and 2 groups with inner (50-100% stratification, whereas cells with thick dendrites were divided into one group with outer and 3 groups with inner stratification. We postulate, that one group of cells with thin dendrites resembles cat ß-cells, whereas one group of cells with thick dendrites includes cells that resemble cat a-cells.

  15. A de Sitter tachyon thick braneworld

    Energy Technology Data Exchange (ETDEWEB)

    Germán, Gabriel; Herrera-Aguilar, Alfredo; Malagón-Morejón, Dagoberto [Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apdo. Postal 48-3, 62251, Cuernavaca, Morelos (Mexico); Mora-Luna, Refugio Rigel [Instituto de Física y Matemáticas, Universidad Michoacana de San Nicolás de Hidalgo, Edificio C-3, Ciudad Universitaria, C.P. 58040, Morelia, Michoacán (Mexico); Rocha, Roldão da, E-mail: gabriel@fis.unam.mx, E-mail: aha@fis.unam.mx, E-mail: malagon@ifm.umich.mx, E-mail: rigel@ifm.umich.mx, E-mail: roldao.rocha@ufabc.edu.br [Centro de Matemática, Computação e Cognição, Universidade Federal do ABC, Rua Santa Adélia, 166 09210-170, Santo André, SP (Brazil)

    2013-02-01

    Among the multiple 5D thick braneworld models that have been proposed in the last years, in order to address several open problems in modern physics, there is a specific one involving a tachyonic bulk scalar field. Delving into this framework, a thick braneworld with a cosmological background induced on the brane is here investigated. The respective field equations — derived from the model with a warped 5D geometry — are highly non-linear equations, admitting a non-trivial solution for the warp factor and the tachyon scalar field as well, in a de Sitter 4D cosmological background. Moreover, the non-linear tachyonic scalar field, that generates the brane in complicity with warped gravity, has the form of a kink-like configuration. Notwithstanding, the non-linear field equations restricting character does not allow one to easily find thick brane solutions with a decaying warp factor which leads to the localization of 4D gravity and other matter fields. We derive such a thick brane configuration altogether in this tachyon-gravity setup. When analyzing the spectrum of gravity fluctuations in the transverse traceless sector, the 4D gravity is shown to be localized due to the presence of a single zero mode bound state, separated by a continuum of massive Kaluza-Klein (KK) modes by a mass gap. It contrasts with previous results, where there is a KK massive bound excitation providing no clear physical interpretation. The mass gap is determined by the scale of the metric parameter H. Finally, the corrections to Newton's law in this model are computed and shown to decay exponentially. It is in full compliance to corrections reported in previous results (up to a constant factor) within similar braneworlds with induced 4D de Sitter metric, despite the fact that the warp factor and the massive modes have a different form.

  16. The Distribution of Macular Thickness and Its Determinants in a Healthy Population.

    Science.gov (United States)

    Hashemi, Hassan; Khabazkhoob, Mehdi; Yekta, AbbasAli; Emamian, Mohammad Hassan; Nabovati, Payam; Fotouhi, Akbar

    2017-10-01

    To determine the distribution of macular thickness in a healthy Iranian population aged 45-69 years and its association with certain determinants. All participants underwent optometric examinations including measurement of uncorrected and corrected visual acuity, objective refraction by retinoscopy, and subjective refraction. Subsequently, all participants underwent slit-lamp biomicroscopy followed by fundus examination through direct and indirect ophthalmoscopy, and optical coherence tomography (OCT) imaging under pupil dilation. Mean central macular thickness was 255.4 µm (95% confidence interval, CI, 254.5-256.3 µm), average inner macular thickness was 316.5 µm (95% CI 315.9-317.1 µm), average outer macular thickness was 275.3 µm (95% CI 274.8-275.8 µm), and overall average thickness was 278.6 µm (95% CI 278.1-279.1 µm). A linear multiple regression model showed that all indexes were significantly larger in male participants (p < 0.001). Central macular thickness increased with age (coef = 0.25, p < 0.001) while overall, inner and outer macular thickness decreased with age (coef = -0.18, -0.15, -0.19, respectively, all p < 0.001). Central and inner macular thickness had a positive correlation (coef = 3.8, 2.6, respectively, both p < 0.001) and outer macular thickness had a negative correlation (coef = -1.6, p < 0.001) with axial length. Age, sex, refractive error, axial length, and keratometry were found to be associated with macular thickness. These factors should be taken into account when interpreting macular thickness measurements with spectral-domain OCT.

  17. Automatic measuring system of zirconium thickness for zirconium liner cladding tubes

    International Nuclear Information System (INIS)

    Matsui, K.; Yamaguchi, H.; Hiroshima, T.; Sakamoto, T.; Murayama, R.

    1985-01-01

    An automatic system of pure zirconium liner thickness for zirconium-zircaloy cladding tubes has been successfully developed. The system consists of three parts. (1) An ultrasonic thickness measuring method for mother tubes before cold rolling. (2) An electromagnetic thickness measuring method for the manufactured tubes. (3) An image processing method for the cross sectional view of the manufactured cut tube samples. In Japanese nuclear industry, zirconium-zircaloy cladding tubes have been tested in order to realize load following operation in the atomic power plant. In order to provide for the practical use in the near future, Sumitomo Metal Industries, Ltd. has been studied and established the practical manufacturing process of the zirconium liner cladding tubes. The zirconium-liner cladding tube is a duplex tube comprising an inner layer of pure zirconium bonded to zircaloy metallurgically. The thickness of the pure zirconium is about 10 % of the total wall thickness. Several types of the automatic thickness measuring methods have been investigated instead of the usual microscopic viewing method in which the liner thickness is measured by the microscopic cross sectional view of the cut tube samples

  18. Determination of gold coating thickness measurement by using EDXRF

    International Nuclear Information System (INIS)

    Meor Yusoff Meor Sulaian; Masliana Muslimin; Fadlullah Jili Fursani

    2005-01-01

    The paper relates a study on the development of an analysis procedure for measuring the gold coating thickness using EDXRF technique. Gold coating thickness was measured by relating the counts under the Au L? peak its thickness value. In order to get a reasonably accurate result, a calibration graph was plotted using five gold-coated reference standards of different thickness. The calibration graph shows a straight line for thin coating measurement until 0.9 μm. Beyond this the relationship was not linear and this may be resulted from the self-absorption effect. Quantitative analysis was also performed on two different samples of gold coated jewelry and a phone connector. Result from the phone connector analysis seems to agree with the manufacturer gold coating value. From the analysis of gold-coated jewelry it had been able to differentiate the two articles as gold wash and gold electroplated. (Author)

  19. Thickness-Dependent Surfactant Behavior in Trilayer Polymer Films

    Science.gov (United States)

    Sun, Yan; Shull, Kenneth; Wang, Jin

    2010-03-01

    The ability for thin liquid films to wet and remain thermodynamically stable on top of one another is a fundamental challenge in developing high quality paints, coatings, adhesives, and other industrial products. Since intermolecular interactions and interfacial energies dominate in the film thickness regime from tens to hundreds of nanometers, it is desirable to tune these long-range and short-range forces in a simple, controllable manner. Starting from an unstable model homopolymer bilayer (poly(styrene)/poly(4-vinylpyridine)), we demonstrate that sandwiching an additional homopolymer layer (poly(4-bromostyrene)) between the two layers can provide needed surfactancy. As the thickness of this center layer is increased, the full trilayer transitions from unstable (thin) to stable (moderate) to unstable (thick). We experimentally show using x-ray standing waves generated via total external reflection (TER-XSW), atomic force microscopy (AFM), and time-of-flight secondary ion mass spectroscopy (ToF-SIMS) that this behavior can be directly attributed to the autophobic dewetting phenomenon, in which the surfactant layer is thin enough to remain stable but thick enough to shield the neighboring layers, highlighting a general approach to stabilizing multilayer systems.

  20. Spatial Evolution of the Thickness Variations over a CFRP Laminated Structure

    Science.gov (United States)

    Davila, Yves; Crouzeix, Laurent; Douchin, Bernard; Collombet, Francis; Grunevald, Yves-Henri

    2017-10-01

    Ply thickness is one of the main drivers of the structural performance of a composite part. For stress analysis calculations (e.g., finite element analysis), composite plies are commonly considered to have a constant thickness compared to the reality (coefficients of variation up to 9% of the mean ply thickness). Unless this variability is taken into account reliable property predictions cannot be made. A modelling approach of such variations is proposed using parameters obtained from a 16-ply quasi-isotropic CFRP plate cured in an autoclave. A discrete Fourier transform algorithm is used to analyse the frequency response of the observed ply and plate thickness profiles. The model inputs, obtained by a mathematical representation of the ply thickness profiles, permit the generation of a representative stratification considering the spatial continuity of the thickness variations that are in good agreement with the real ply profiles spread over the composite part. A residual deformation FE model of the composite plate is used to illustrate the feasibility of the approach.

  1. Investigation of top electrode for PZT thick films based MEMS sensors

    DEFF Research Database (Denmark)

    Hindrichsen, Christian Carstensen; Pedersen, Thomas; Kristiansen, Paw T.

    2010-01-01

    In this work processing of screen printed piezoelectric PZT thick films on silicon substrates is investigated for use in future MEMS devices. E-beam evaporated Al and Pt are patterned on PZT as a top electrode using a lift-off process with a line width down to 3 mu m. Three test structures are used...... to investigate the optimal thickness of the top electrode, the degradation of the piezoelectric properties of the PZT film in absence of a diffusion barrier layer and finally how to fabricate electrical interconnects down the edge of the PZT thick film. The roughness of the PZT is found to have a strong...... influence on the conductance of the top electrode influencing the optimal top electrode thickness. A 100 nm thick top electrode on the PZT thick film with a surface roughness of 273 nm has a 4.5 times higher resistance compared to a similar wire on a planar SiO2 surface which has a surface roughness of less...

  2. Evaluation of the room shielding thickness of Hi-Art tomotherapy system

    International Nuclear Information System (INIS)

    Liu Haikuan; Wu Jinhai; Gu Naigu; Gao Yiming; Wang Li; Huang Weiqin; Wang Fengxian

    2010-01-01

    In this paper, we calculate and evaluate the room shielding thickness of a Hi-Art tomotherapy system, which is a new type of radiotherapy facility. Due to the self-shielding of the accelerator,only scattered beam and beam leakage were considered in calculating the room shielding thickness. The radiation field of the tomotherapy system was used as the basic data to calculate the shielding thickness of every 15 degree solid angle. The maximum shielding thickness required of each shielding wall was at the position with the angle of 15 degree, and the calculated shielding thickness were 1023, 975, 917, 1460, 1147 and 1189 mm for the east wall,south wall,west wall, north wall, the roof and the floor,respectively. According to the calculation results, all shielding walls, ceiling and floor could meet the requirement of the radiation protection, but the north wall thickness of 1200 mm was a little thinner. (authors)

  3. Nano-Hydroxyapatite Thick Film Gas Sensors

    International Nuclear Information System (INIS)

    Khairnar, Rajendra S.; Mene, Ravindra U.; Munde, Shivaji G.; Mahabole, Megha P.

    2011-01-01

    In the present work pure and metal ions (Co and Fe) doped hydroxyapatite (HAp) thick films have been successfully utilized to improve the structural, morphological and gas sensing properties. Nanocrystalline HAp powder is synthesized by wet chemical precipitation route, and ion exchange process is employed for addition of Co and Fe ions in HAp matrix. Moreover, swift heavy ion irradiation (SHI) technique is used to modify the surface of pure and metal ion exchanged HAp with various ion fluence. The structural investigation of pure and metal ion exchanged HAp thick films are carried out using X-ray diffraction and the presence of functional group is observed by means FTIR spectroscopy. Furthermore, surface morphology is visualized by means of SEM and AFM analysis. CO gas sensing study is carried out for, pure and metal ions doped, HAp thick films with detail investigation on operating temperature, response/recovery time and gas uptake capacity. The surface modifications of sensor matrix by SHI enhance the gas response, response/recovery and gas uptake capacity. The significant observation is here to note that, addition of Co and Fe in HAp matrix and surface modification by SHI improves the sensing properties of HAp films drastically resulting in gas sensing at relatively lower temperatures.

  4. Variations of retinal nerve fiber layer thickness and ganglion cell-inner plexiform layer thickness according to the torsion direction of optic disc.

    Science.gov (United States)

    Lee, Kang Hoon; Kim, Chan Yun; Kim, Na Rae

    2014-02-20

    To examine the relationship between the optic disc torsion and peripapillary retinal nerve fiber layer (RNFL) thickness through a comparison with the macular ganglion cell inner plexiform layer complex (GCIPL) thickness measured by Cirrus optical coherence tomography (OCT). Ninety-four eyes of 94 subjects with optic disc torsion and 114 eyes of 114 subjects without optic disc torsion were enrolled prospectively. The participants underwent fundus photography and OCT imaging in peripapillary RNFL mode and macular GCIPL mode. The participants were divided into groups according to the presence or absence of optic disc torsion. The eyes with optic disc torsion were further divided into supranasal torsion and inferotemporal torsion groups according to the direction of optic disc torsion. The mean RNFL and GCIPL thicknesses for the quadrants and subsectors were compared. The superior and inferior peak locations of the RNFL were also measured according to the torsion direction. The temporal RNFL thickness was significantly thicker in inferotemporal torsion, whereas the GCIPL thickness at all segments was unaffected. The inferotemporal optic torsion had more temporally positioned superior peak locations of the RNFL than the nontorsion and supranasal-torted optic disc. Thickening of the temporal RNFL with a temporal shift in the superior peak within the eyes with inferotemporal optic disc torsion can lead to interpretation errors. The ganglion cell analysis algorithm can assist in differentiating eyes with optic disc torsion.

  5. The critical thickness of liners of Cu interconnects

    International Nuclear Information System (INIS)

    Jiang, Q; Zhang, S H; Li, J C

    2004-01-01

    A model for the size-dependence of activation energy is developed. With the model and Fick's second law, relationships among the liner thickness, the working life and the working temperature of a TaN liner for Cu interconnects are predicted. The predicted results of the TaN liner are in good agreement with the experimental results. Moreover, the critical thicknesses of liners of some elements are calculated

  6. Orientation acoustic radiation of electrons in silicon thick crystal

    International Nuclear Information System (INIS)

    Alejnik, A.N.; Afanas'ev, S.G.; Vorob'ev, S.A.; Zabaev, V.N.; Il'in, S.I.; Kalinin, B.N.; Potylitsyn, A.P.

    1989-01-01

    Results of measuring orientation acoustic radiation of 900 and 500 MeV electrons during their movement along crystallographic axis in thick silicon crystal (h=20 mm thickness) are presented for the first time. Analysis of obtained results shows that dynamic mechanism describes rather completely the main regularities of orientation dependence of the amplitude of acoustic signal occuring under electron motion near crystallographic axis of the crystal. Phenomena of orientation acoustic radiation can be also used for investigation of solid bodies. Orientation both of thin and rather thick monocrystals can be conducted on the basis of dynamic mechanism of elastic wave excitation in crystals

  7. Mechanical properties of F82H plates with different thicknesses

    Energy Technology Data Exchange (ETDEWEB)

    Sakasegawa, Hideo, E-mail: sakasegawa.hideo@jaea.go.jp; Tanigawa, Hiroyasu

    2016-11-01

    Highlights: • Mass effect, homogeneity, and anisotropy in mechanical properties were studied. • Thickness dependence of tensile property was not observed. • Thickness dependence of Charpy impact property was observed. • Appropriate mechanical properties were obtained using an electric furnace. - Abstract: Fusion DEMO reactor requires over 11,000 tons of reduced activation ferritic/martensitic steel and it is indispensable to develop the manufacturing technology for producing large-scale components of DEMO blanket with appropriate mechanical properties. This is because mechanical properties are generally degraded with increasing production volume. In this work, we focused mechanical properties of F82H–BA12 heat which was melted in a 20 tons electric arc furnace. Plates with difference thicknesses from 18 to 100 mm{sup t} were made from its ingot through forging and hot-rolling followed by heat treatments. Tensile and Charpy impact tests were then performed on plates focusing on their homogeneity and anisotropy. From the result, their homogeneity and anisotropy were not significant. No obvious differences were observed in tensile properties between the plates with different thicknesses. However, Charpy impact property changed with increasing plate thickness, i.e. the ductile brittle transition temperature of a 100 mm{sup t} thick plate was higher than that of the other thinner plates.

  8. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  9. Influence of ni thickness on oscillation coupling in Cu/Ni multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Gagorowska, B; Dus-Sitek, M [Institute of Physics, Czestochowa University of Technology, Al. Armii Krajowej 19, 42-200 Czestochowa (Poland)

    2007-08-15

    The results of investigation of magnetic properties of [Cu/Ni]x100 were presented. Samples were deposited by face-to-face sputtering method onto the silicon substrate, the thickness of Cu layer was constant (d{sub Cu} = 2 nm) and the thickness of Ni layer - variable (1 nm {<=} d{sub Ni} {<=} 6 nm). In Cu/Ni multilayers, for the thickness of Ni layer bigger than 2 nm antiferromagnetic coupling (A-F) were observed, for the thickness of Ni smaller than 2 nm A-F coupling is absent.

  10. Influence of ni thickness on oscillation coupling in Cu/Ni multilayers

    International Nuclear Information System (INIS)

    Gagorowska, B; Dus-Sitek, M

    2007-01-01

    The results of investigation of magnetic properties of [Cu/Ni]x100 were presented. Samples were deposited by face-to-face sputtering method onto the silicon substrate, the thickness of Cu layer was constant (d Cu = 2 nm) and the thickness of Ni layer - variable (1 nm ≤ d Ni ≤ 6 nm). In Cu/Ni multilayers, for the thickness of Ni layer bigger than 2 nm antiferromagnetic coupling (A-F) were observed, for the thickness of Ni smaller than 2 nm A-F coupling is absent

  11. Sonographic Measurement of AP Diameter and Wall Thickness of the Gallbladder

    International Nuclear Information System (INIS)

    Chung, S.K.; Lee, J. S.; Huh, S. J.; Baek, I. S.

    1982-01-01

    Call bladder size and wall thickness are important in the assessment of the pathologic condition. Authors have measured AP diameter of gallbladder and evaluated the change of all thickness between fasting and postprandial state. The results were as follows: 1. The mean of AP diameter was 2.18+0.49cm 2. The wall thickness was 2.7+0.6mm in fasting state and 3.3+0.8mm after meal. 3. The increase of wall thickness after fat meal was significant statistically(p<.001)

  12. Interplay between total thickness and period thickness in the phonon thermal conductivity of superlattices from the nanoscale to the microscale: Coherent versus incoherent phonon transport

    Science.gov (United States)

    Cheaito, Ramez; Polanco, Carlos A.; Addamane, Sadhvikas; Zhang, Jingjie; Ghosh, Avik W.; Balakrishnan, Ganesh; Hopkins, Patrick E.

    2018-02-01

    We report on the room temperature thermal conductivity of AlAs-GaAs superlattices (SLs), in which we systematically vary the period thickness and total thickness between 2 -24 nm and 20.1 -2 ,160 nm , respectively. The thermal conductivity increases with the SL thickness and plateaus at a thickness around 200 nm, showing a clear transition from a quasiballistic to a diffusive phonon transport regime. These results demonstrate the existence of classical size effects in SLs, even at the highest interface density samples. We use harmonic atomistic Green's function calculations to capture incoherence in phonon transport by averaging the calculated transmission over several purely coherent simulations of independent SL with different random mixing at the AlAs-GaAs interfaces. These simulations demonstrate the significant contribution of incoherent phonon transport through the decrease in the transmission and conductance in the SLs as the number of interfaces increases. In spite of this conductance decrease, our simulations show a quasilinear increase in thermal conductivity with the superlattice thickness. This suggests that the observation of a quasilinear increase in thermal conductivity can have important contributions from incoherent phonon transport. Furthermore, this seemingly linear slope in thermal conductivity versus SL thickness data may actually be nonlinear when extended to a larger number of periods, which is a signature of incoherent effects. Indeed, this trend for superlattices with interatomic mixing at the interfaces could easily be interpreted as linear when the number of periods is small. Our results reveal that the change in thermal conductivity with period thickness is dominated by incoherent (particlelike) phonons, whose properties are not dictated by changes in the AlAs or GaAs phonon dispersion relations. This work demonstrates the importance of studying both period and sample thickness dependencies of thermal conductivity to understand the

  13. CT measurement of normal pericardial thickness in adults on computed tomography

    International Nuclear Information System (INIS)

    Choi, Young Woo; Park, Chan Sup; Jeon, Yong Sun; Bae, In Young; Choi, Sung Gyu; Koo, Jin Hoe; Chung, Won Kyun

    1998-01-01

    The purpose of this study was to establish, using computed tomography, the normal thickness of the pericardium in adults. Materials and Methods: CT scans of 50 patients, including sections through the level of the heart, were reviewed. Patients were excluded if there were any suspicions of pericardial abnormality such as infectious or neoplastic diseases. Twenty-four of the 50 were men and 26 were women; their mean age was 47.0(range,18-76) years. We measured pericardial thickness at the level of the right ventricle, interventricular septum and left ventricle, and also compared pericardial thickness in terms of age and sex. Results: In all patients, the pericardium was observed in the right ventricular region; in 41 (82%) at the interventricular septum; and in 41 (82%) along the left ventricle. The mean thickness of normal pericardium at the level of the right ventricle, interventricular septum, and left ventricle was 1.8 mm ± 0.5 mm, 1.8 mm ± 0.4 mm, and 1.7 mm ± 0.5 mm, respectively. No statistically significant correlation was apparent between pericardial thickness and age group (p > 0.63, ANOVA test). Mean pericardial thickness was 1.9 mm ± 0.6 mm in males and 1.7 mm ± 0.4 mm in females; thus, no statistically significant correlation was apparent between pericardial thickness and sex (p >0.29, Student's t-test). Conclusion: The pericardium was best visualized in sections through the right ventricle.The mean thickness of normal pericardium was 1.8 mm ± 0.5 mm and pericardial thickness did not differ according to age or sex

  14. Hot rolling of thick uranium molybdenum alloys

    Science.gov (United States)

    DeMint, Amy L.; Gooch, Jack G.

    2015-11-17

    Disclosed herein are processes for hot rolling billets of uranium that have been alloyed with about ten weight percent molybdenum to produce cold-rollable sheets that are about one hundred mils thick. In certain embodiments, the billets have a thickness of about 7/8 inch or greater. Disclosed processes typically involve a rolling schedule that includes a light rolling pass and at least one medium rolling pass. Processes may also include reheating the rolling stock and using one or more heavy rolling passes, and may include an annealing step.

  15. Glue Film Thickness Measurements by Spectral Reflectance

    International Nuclear Information System (INIS)

    Marshall, B.R.

    2010-01-01

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 (micro)m, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  16. Glue Film Thickness Measurements by Spectral Reflectance

    Energy Technology Data Exchange (ETDEWEB)

    B. R. Marshall

    2010-09-20

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  17. The critical oxide thickness for Pb-free reflow soldering on Cu substrate

    Energy Technology Data Exchange (ETDEWEB)

    Chung, C. Key [Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan (China); Assembly Test Global Materials, Intel Microelectronics Asia Ltd, B1, No. 205, Tun-Hwa North Road, 10595 Taipei, Taiwan (China); Chen, Y.J.; Li, C.C. [Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan (China); Kao, C.R., E-mail: crkao@ntu.edu.tw [Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan (China)

    2012-06-01

    Oxidation is an undesirable effect of reflow soldering. Non-wetting occurs when the oxide layer grows above the critical thickness. Characterizing the critical oxide thickness for soldering is challenging due to oxide's nano-scale thickness and irregular topographic surface. In this paper, the critical copper oxide thickness was characterized by Time-of-Flight Secondary Ion Mass Spectrometry, Scanning Electron Microscopy, Energy-Dispersive X-ray spectroscopy, and Transmission Electron Microscopy. Copper substrates were coated with an Organic-Solderable-Preservative (OSP) layer and baked at 150 Degree-Sign C and 85% Relative Humidity for different amounts of time. The onset of the non-wetting phenomenon occurred when the oxide thickness reached 18 {+-} 5 nm. As the oxide grew beyond this critical thickness, the percentage of non-wetting solder joint increased exponentially. The growth of the oxide thickness followed a parabolic rate law. The rate constant of oxidation was 0.6 Multiplication-Sign 10{sup -15} cm{sup 2} min{sup -1}. Oxidation resulted from interdiffusion of copper and oxygen atoms through the OSP and oxide layers. The oxidation mechanism will be presented and discussed. - Highlights: Black-Right-Pointing-Pointer Critical oxide thickness for Pb free solder on Cu substrate is 18 {+-} 5 nm. Black-Right-Pointing-Pointer Above the critical oxide, non-wet solder joint increases exponentially. Black-Right-Pointing-Pointer A maximum 13-nm oxide thickness is suggested for good solder joint. Black-Right-Pointing-Pointer Initial growth of oxide thickness is logarithmic and then parabolic after 12 nm. Black-Right-Pointing-Pointer Thick oxide (360-560 nm) is formed as pores shorten the oxidation path.

  18. ORIGIN OF CHEMICAL AND DYNAMICAL PROPERTIES OF THE GALACTIC THICK DISK

    International Nuclear Information System (INIS)

    Bekki, Kenji; Tsujimoto, Takuji

    2011-01-01

    We adopt a scenario in which the Galactic thick disk was formed by minor merging between the first generation of the Galactic thin disk (FGTD) and a dwarf galaxy about ∼9 Gyr ago and thereby investigate chemical and dynamical properties of the Galactic thick disk. In this scenario, the dynamical properties of the thick disk have long been influenced both by the mass growth of the second generation of the Galactic thin disk (i.e., the present thin disk) and by its non-axisymmetric structures. On the other hand, the early star formation history and chemical evolution of the thin disk was influenced by the remaining gas of the thick disk. Based on N-body simulations and chemical evolution models, we investigate the radial metallicity gradient, structural and kinematical properties, and detailed chemical abundance patterns of the thick disk. Our numerical simulations show that the ancient minor merger event can significantly flatten the original radial metallicity gradient of the FGTD, in particular, in the outer part, and also can be responsible for migration of inner metal-rich stars into the outer part (R > 10 kpc). The simulations show that the central region of the thick disk can develop a bar due to dynamical effects of a separate bar in the thin disk. Whether or not rotational velocities (V φ ) can correlate with metallicities ([Fe/H]) for the simulated thick disks depends on the initial metallicity gradients of the FGTDs. The simulated orbital eccentricity distributions in the thick disk for models with higher mass ratios (∼0.2) and lower orbital eccentricities (∼0.5) of minor mergers are in good agreement with the corresponding observations. The simulated V φ -|z| relation of the thick disk in models with low orbital inclination angles of mergers are also in good agreement with the latest observational results. The vertical metallicity gradient of the simulated thick disk is rather flat or very weakly negative in the solar neighborhood. Our Galactic

  19. Compton-thick AGN at high and low redshift

    Science.gov (United States)

    Akylas, A.; Georgantopoulos, I.; Corral, A.; Ranalli, P.; Lanzuisi, G.

    2017-10-01

    The most obscured sources detected in X-ray surveys, the Compton-thick AGN present great interest both because they represent the hidden side of accretion but also because they may signal the AGN birth. We analyse the NUSTAR observations from the serendipitous observations in order to study the Compton-thick AGN at the deepest possible ultra-hard band (>10 keV). We compare our results with our SWIFT/BAT findings in the local Universe, as well as with our results in the CDFS and COSMOS fields. We discuss the comparison with X-ray background synthesis models finding that a low fraction of Compton-thick sources (about 15 per cent of the obscured population) is compatible with both the 2-10keV band results and those at harder energies.

  20. 3D electroplated inductors with thickness variation for improved broadband performance

    Science.gov (United States)

    Farm-Guoo Tseng, Victor; Bedair, Sarah S.; Lazarus, Nathan

    2017-01-01

    The performance of an RF spiral inductor is based on the balance between ohmic losses in the outer turns and eddy current losses dominant in the inner turns where the magnetic field is the strongest. In this work, air-core spiral inductors with winding trace thicknesses decreasing towards the center are demonstrated, achieving quality factor improvement over a wide frequency range compared to uniform thickness inductors. A custom 3D copper electroplating process was used to produce spiral inductors with varying winding thicknesses in a single plating step, with patterned gaps in a seed layer used to create delays in the vertical plating. The fabricated center-lowered coil inductors were 80 nH within a one square millimeter area with thickness varying from 60 µm to 10 µm from outer to inner winding. Within the 16 MHz-160 MHz range, the center-lowered inductors were shown to have a maximum to minimum quality factor improvement of 90%-10% when compared to uniform thickness inductors with thicknesses ranging from 60 µm to 10 µm. Compared to the 20 µm uniform thickness inductor which has the optimal performance among all uniform thickness inductors in this frequency range, the center-lowered inductors were shown to achieve a maximum quality factor improvement of 20% at the edge frequencies of 16 MHz and 160 MHz, and a minimum quality factor improvement of 10% near the geometric mean center frequency of 46 MHz.

  1. Mortality by Level of Emphysema and Airway Wall Thickness

    DEFF Research Database (Denmark)

    Johannessen, Ane; Skorge, Trude Duelien; Bottai, Matteo

    2013-01-01

    There is limited knowledge of the prognostic value of quantitative computed tomography (CT) measures of emphysema and airway wall thickness (AWT) on mortality.......There is limited knowledge of the prognostic value of quantitative computed tomography (CT) measures of emphysema and airway wall thickness (AWT) on mortality....

  2. Faraday effect in hollow quantum cylinder of finite thickness

    International Nuclear Information System (INIS)

    Ismailov, T.G.; Jabrailova, G.G.

    2009-01-01

    The interband Faraday rotation in hollow quantum cylinder of finite thickness is theoretically investigated. Faraday rotation in the dependence on incident light energy for different values of cylinder thickness. It is seen that the resonance peaks appear on Faraday rotation curve. The roles of selection are obtained

  3. Correlation between choroidal thickness and macular hole

    Directory of Open Access Journals (Sweden)

    Li-Li Wang

    2018-01-01

    Full Text Available AIM:To explore the correlation between choroidal thickness and macular hole, and to provide a theoretical basis for diagnosis and treatment of macular hole. METHODS: This study included 40 cases of monocular idiopathic macular hole patients who were treated in ophthalmology of our hospital from June 2015 to June 2016 and 40 cases of healthy people. Sicked eyes of idiopathic macular hole patients(40 eyeswere set as the Group A, uninjured side eyes(40 eyeswere set as the Group B, eyes of 40 cases of healthy people(40 normal eyeswere set as the Group C. Choroidal thickness of macular fovea, macular fovea 1mm, 3mm at 9 points, 4 directions in the upper, lower, nasal and temporal regions were measured through coherent optical tomography of enhanced deep imaging(enhanced depth image optical coherence tomography, EDI-OCT. They were recorded as SFCT, SCT1mm, SCT3mm, ICT1mm, ICT3mm, NCT1mm, NCT3mm, TCT1mm, TCT3mm, and correlation analysis between SFCT and age was analyzed. RESULTS: Average SFCT of Group A, B had no significant difference, data of the Group C was significantly higher than those of the Group A, B, there was statistical significance(P1mm, SCT3mm, ICT1mm, ICT3mm, NCT1mm, NCT3mm, TCT1mm, TCT3mm of the Group A, B had no significant difference(P>0.05, and choroidal thickness at each point of the Group C was significantly higher than that of Group A and B, there was statistical significance(Pr=-0.065, P=0.148; r=-0.057, P=0.658, SFCT of the Group C was negatively correlated with age(r=-0.343, P=0.041. CONCLUSION: The pathogenesis of idiopathic macular hole may be related to the sharp decrease of choroidal thickness, choroidal thickness of uninjured side eyes reduces more sharply than normal population and choroidal vascular metabolism reduces may be pathogenic.

  4. THE EFFECT OF THE BACKFAT THICKNESS LOSS ON REPRODUCTION IN LACTATING SOWS

    Directory of Open Access Journals (Sweden)

    Luboš Brzobohatý

    2015-06-01

    Full Text Available The work discusses the influence of the backfat thickness change, during sow´s lactation, on their subsequent litter characteristics. The reproduction potential of 478 sows of two genotypes was assessed. The genotypes were 50 Large White (LWD sows and 428 crossbreeds Large White x Landrace (LWD x L sows. The backfat thickness decline was examined in accordance to P2, backfat thickness in sows during lactation namely 1 day before planned parturition as well as weaning. From the obtained results it can be stated that the backfat thickness decline level during lactation has a small influence on the number of total born piglets. In contrast, the number of piglets born alive increased when backfat thickness rate increased. With a moderate backfat thickness decline, the average birthweight piglets gradually increased. However, the opposite trend was shown for the average weight at weaning. The backfat thickness decline level during sow´s lactation influences their farrowing interval. Animals with a lower increase of the backfat thickness subsequently showed a shorter farrowing interval (148.99, respectively 151.86 days, as well as a shorter weaning – estrus interval.

  5. Load bearing capacity of welded joints between dissimilar pipelines with unequal wall thickness

    Energy Technology Data Exchange (ETDEWEB)

    Beak, Jonghyun; Kim, Youngpyo; Kim, Woosik [Korea Gas Corporation, Suwon (Korea, Republic of)

    2012-09-15

    The behavior of the load bearing capacity of a pipeline with unequal wall thickness was evaluated using finite element analyses. Pipelines with a wall thickness ratio of 1.22-1.89 were adopted to investigate plastic collapse under tensile, internal pressure, or bending stress. A parametric study showed that the tensile strength and moment of a pipeline with a wall thickness ratio less than 1.5 were not influenced by the wall thickness ratio and taper angle; however, those of a pipeline with a wall thickness ratio more than 1.5 decreased considerably at a low taper angle. The failure pressure of a pipeline with unequal wall thickness was not influenced by the wall thickness ratio and taper angle.

  6. The Effect of Eggshell Thickness on Hatching Traits of Partridges

    Directory of Open Access Journals (Sweden)

    US Yamak

    Full Text Available ABSTRACT Incubation is an important factor in poultry production, particularly in species with relatively low fertility and hatchability rates. This study examined the effect of eggshell thickness on hatching traits of partridges (A. chukar. A total of 462 eggs from intensively reared partridges were separated into three groups according to eggshell thickness, which was measured ultrasonically before incubation. Hatchability, chick weight, and chick length were assessed at the end of the incubation period. Hatching times were recorded during hatching. Embryonic mortalities in unhatched eggs were classified according to mortality stage at the end of incubation. The effect of eggshell thickness on hatchability was found to be insignificant for all groups. Moreover, eggshell thickness had no significant effect on chick weight or length.

  7. THICK-DISK EVOLUTION INDUCED BY THE GROWTH OF AN EMBEDDED THIN DISK

    International Nuclear Information System (INIS)

    Villalobos, Alvaro; Helmi, Amina; Kazantzidis, Stelios

    2010-01-01

    We perform collisionless N-body simulations to investigate the evolution of the structural and kinematical properties of simulated thick disks induced by the growth of an embedded thin disk. The thick disks used in the present study originate from cosmologically common 5:1 encounters between initially thin primary disk galaxies and infalling satellites. The growing thin disks are modeled as static gravitational potentials and we explore a variety of growing-disk parameters that are likely to influence the response of thick disks. We find that the final thick-disk properties depend strongly on the total mass and radial scale length of the growing thin disk, and much less sensitively on its growth timescale and vertical scale height as well as the initial sense of thick-disk rotation. Overall, the growth of an embedded thin disk can cause a substantial contraction in both the radial and vertical direction, resulting in a significant decrease in the scale lengths and scale heights of thick disks. Kinematically, a growing thin disk can induce a notable increase in the mean rotation and velocity dispersions of thick-disk stars. We conclude that the reformation of a thin disk via gas accretion may play a significant role in setting the structure and kinematics of thick disks, and thus it is an important ingredient in models of thick-disk formation.

  8. Effects of CPAP therapy on visceral fat thickness, carotid intima-media thickness and adipokines in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Ng, Susanna S S; Liu, Eric K H; Ma, Ronald C W; Chan, Tat-On; To, Kin-Wang; Chan, Ken K P; Ngai, Jenny; Yip, Wing-Ho; Ko, Fanny W S; Wong, Chun-Kwok; Hui, David S C

    2017-05-01

    Obstructive sleep apnoea (OSA) is associated with an increased prevalence of metabolic syndrome. This study explores the effects of continuous positive airway pressure (CPAP) for patients with OSA on visceral and mesenteric fat thickness, carotid intima-media thickness (IMT) and adipokines. A randomized controlled study was conducted at a teaching hospital on 90 patients newly diagnosed with OSA to receive either therapeutic CPAP or subtherapeutic CPAP for 3 months. Visceral fat thickness and carotid IMT were measured with B-mode ultrasound; adipokine levels were assessed at baseline and 3 months. Altogether, 45 patients received therapeutic CPAP and 45 received subtherapeutic CPAP without significant differences in age 50.3 (10.1) versus 48.7 (9.0) years, BMI 28.2 (3.9) versus 28.2 (4.5) kg/m 2 , Epworth Sleepiness Scale (ESS) 12.4 (5.9) versus 11.3 (4.7), apnoea-hypopnoea index (AHI) 30.6 (21.4) versus 35.2 (25.5) /h, minimum SaO 2 79.6 (10.8) versus 76.7 (12.4) % and existing co-morbidities. CPAP usage was therapeutic 4.2 (2.1) versus subtherapeutic 4.1 (2.0) h/night over 3 months. Adiponectin and irisin levels changed significantly following therapeutic CPAP for 3 months versus subtherapeutic CPAP (-1.6 vs 7.3, P = 0.042; 0.1 vs -0.1, P = 0.028 respectively) while only serum level of monocyte chemotactic protein 1 (MCP-1) at baseline was positively correlated with AHI (r = 0.278). No significant changes were observed in other adipokines, visceral fat thickness and IMT. Short-term therapeutic CPAP versus subtherapeutic CPAP does not significantly reduce visceral fat thickness and IMT, although it reduces adiponectin and increases irisin. © 2016 Asian Pacific Society of Respirology.

  9. Comparison of lateral abdominal muscle thickness between weightlifters and matched controls.

    Science.gov (United States)

    Sitilertpisan, Patraporn; Pirunsan, Ubon; Puangmali, Aatit; Ratanapinunchai, Jonjin; Kiatwattanacharoen, Suchart; Neamin, Hudsaleark; Laskin, James J

    2011-11-01

    To compare lateral abdominal muscle thickness between weightlifters and matched controls. A case control study design. University laboratory. 16 female Thai national weightlifters and 16 matched controls participated in this study. Ultrasound imaging with a 12-MHz linear array was used to measure the resting thickness of transversus abdominis (TrA), internal oblique (IO) and total thickness (Total) of lateral abdominal muscle (LAM) on the right side of abdominal wall. The absolute muscle thickness and the relative contribution of each muscle to the total thickness were determined. Weightlifters had significantly thicker absolute TrA and IO muscles than matched controls (p routine Olympic style weight training among female weightlifters appears to result in preferential hypertrophy or adaptation of the IO muscle. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Effect of thickness on optical properties of thermally evaporated SnS films

    International Nuclear Information System (INIS)

    Selim, M.S.; Gouda, M.E.; El-Shaarawy, M.G.; Salem, A.M.; Abd El-Ghany, W.A.

    2013-01-01

    The effect of film thickness on the structure and optical properties of thermally evaporated SnS film has been studied. SnS films with different thicknesses in the range 152–585 nm were deposited onto clean glass substrates at room temperature. X-ray diffraction study revealed that SnS films of thickness ≥ 283 nm are crystalline, whereas films of lower thickness exhibit poor crystalline with more amorphous background. The crystalline nature of the lower film thickness has been confirmed using transmission electron microscope and the corresponding electron diffraction pattern. The thicker film samples showed nearly stoichiometric chemical composition; however, thinner samples are deficient in S and rich in Sn. The optical property of the deposited films has been investigated in the wavelength range 350–2500 nm. The refractive index increases notably with increasing film thickness. The refractive index for the investigated film thicknesses are adequately described by the effective-single-oscillator model. The static refractive index and the static dielectric constant have been calculated. Analysis of the optical absorption coefficient revealed the presence of direct optical transition and the corresponding band gap values were found to decrease as the film thickness increases. - Highlights: ► X-ray diffraction was used to study the structure of SnS films. ► Transmission electron microscope confirms the crystalline state of SnS films. ► The refractive index increases notably with increasing the film thickness. ► The optical band gap of SnS films decreases with increasing film thickness

  11. Three-dimensional bioprinting of thick vascularized tissues

    Science.gov (United States)

    Kolesky, David B.; Homan, Kimberly A.; Skylar-Scott, Mark A.; Lewis, Jennifer A.

    2016-03-01

    The advancement of tissue and, ultimately, organ engineering requires the ability to pattern human tissues composed of cells, extracellular matrix, and vasculature with controlled microenvironments that can be sustained over prolonged time periods. To date, bioprinting methods have yielded thin tissues that only survive for short durations. To improve their physiological relevance, we report a method for bioprinting 3D cell-laden, vascularized tissues that exceed 1 cm in thickness and can be perfused on chip for long time periods (>6 wk). Specifically, we integrate parenchyma, stroma, and endothelium into a single thick tissue by coprinting multiple inks composed of human mesenchymal stem cells (hMSCs) and human neonatal dermal fibroblasts (hNDFs) within a customized extracellular matrix alongside embedded vasculature, which is subsequently lined with human umbilical vein endothelial cells (HUVECs). These thick vascularized tissues are actively perfused with growth factors to differentiate hMSCs toward an osteogenic lineage in situ. This longitudinal study of emergent biological phenomena in complex microenvironments represents a foundational step in human tissue generation.

  12. Hexaferrite multiferroics: from bulk to thick films

    Science.gov (United States)

    Koutzarova, T.; Ghelev, Ch; Peneva, P.; Georgieva, B.; Kolev, S.; Vertruyen, B.; Closset, R.

    2018-03-01

    We report studies of the structural and microstructural properties of Sr3Co2Fe24O41 in bulk form and as thick films. The precursor powders for the bulk form were prepared following the sol-gel auto-combustion method. The prepared pellets were synthesized at 1200 °C to produce Sr3Co2Fe24O41. The XRD spectra of the bulks showed the characteristic peaks corresponding to the Z-type hexaferrite structure as a main phase and second phases of CoFe2O4 and Sr3Fe2O7-x. The microstructure analysis of the cross-section of the bulk pellets revealed a hexagonal sheet structure. Large areas were observed of packages of hexagonal sheets where the separate hexagonal particles were ordered along the c axis. Sr3Co2Fe24O41 thick films were deposited from a suspension containing the Sr3Co2Fe24O41 powder. The microstructural analysis of the thick films showed that the particles had the perfect hexagonal shape typical for hexaferrites.

  13. Ice thickness measurements and volume estimates for glaciers in Norway

    Science.gov (United States)

    Andreassen, Liss M.; Huss, Matthias; Melvold, Kjetil; Elvehøy, Hallgeir; Winsvold, Solveig H.

    2014-05-01

    Whereas glacier areas in many mountain regions around the world now are well surveyed using optical satellite sensors and available in digital inventories, measurements of ice thickness are sparse in comparison and a global dataset does not exist. Since the 1980s ice thickness measurements have been carried out by ground penetrating radar on many glaciers in Norway, often as part of contract work for hydropower companies with the aim to calculate hydrological divides of ice caps. Measurements have been conducted on numerous glaciers, covering the largest ice caps as well as a few smaller mountain glaciers. However, so far no ice volume estimate for Norway has been derived from these measurements. Here, we give an overview of ice thickness measurements in Norway, and use a distributed model to interpolate and extrapolate the data to provide an ice volume estimate of all glaciers in Norway. We also compare the results to various volume-area/thickness-scaling approaches using values from the literature as well as scaling constants we obtained from ice thickness measurements in Norway. Glacier outlines from a Landsat-derived inventory from 1999-2006 together with a national digital elevation model were used as input data for the ice volume calculations. The inventory covers all glaciers in mainland Norway and consists of 2534 glaciers (3143 glacier units) covering an area of 2692 km2 ± 81 km2. To calculate the ice thickness distribution of glaciers in Norway we used a distributed model which estimates surface mass balance distribution, calculates the volumetric balance flux and converts it into thickness using the flow law for ice. We calibrated this model with ice thickness data for Norway, mainly by adjusting the mass balance gradient. Model results generally agree well with the measured values, however, larger deviations were found for some glaciers. The total ice volume of Norway was estimated to be 275 km3 ± 30 km3. From the ice thickness data set we selected

  14. Increased-resolution OCT thickness mapping of the human macula: a statistically based registration.

    Science.gov (United States)

    Bernardes, Rui; Santos, Torcato; Cunha-Vaz, José

    2008-05-01

    To describe the development of a technique that enhances spatial resolution of retinal thickness maps of the Stratus OCT (Carl Zeiss Meditec, Inc., Dublin, CA). A retinal thickness atlas (RT-atlas) template was calculated, and a macular coordinate system was established, to pursue this objective. The RT-atlas was developed from principal component analysis of retinal thickness analyzer (RTA) maps acquired from healthy volunteers. The Stratus OCT radial thickness measurements were registered on the RT-atlas, from which an improved macular thickness map was calculated. Thereafter, Stratus OCT circular scans were registered on the previously calculated map to enhance spatial resolution. The developed technique was applied to Stratus OCT thickness data from healthy volunteers and from patients with diabetic retinopathy (DR) or age-related macular degeneration (AMD). Results showed that for normal, or close to normal, macular thickness maps from healthy volunteers and patients with DR, this technique can be an important aid in determining retinal thickness. Efforts are under way to improve the registration of retinal thickness data in patients with AMD. The developed technique enhances the evaluation of data acquired by the Stratus OCT, helping the detection of early retinal thickness abnormalities. Moreover, a normative database of retinal thickness measurements gained from this technique, as referenced to the macular coordinate system, can be created without errors induced by missed fixation and eye tilt.

  15. Thickness optimization of the ZnO based TCO layer in a CZTSSe solar cell. Evolution of its performance with thickness when external temperature changes.

    Science.gov (United States)

    Chadel, Meriem; Moustafa Bouzaki, Mohammed; Chadel, Asma; Aillerie, Michel; Benyoucef, Boumediene

    2017-07-01

    The influence of the thickness of a Zinc Oxide (ZnO) transparent conductive oxide (TCO) layer on the performance of the CZTSSe solar cell is shown in detail. In a photovoltaic cell, the thickness of each layer largely influence the performance of the solar cell and optimization of each layer constitutes a complete work. Here, using the Solar Cell Capacitance Simulation (SCAPS) software, we present simulation results obtained in the analyze of the influence of the TCO layer thickness on the performance of a CZTSSe solar cell, starting from performance of a CZTSSe solar cell commercialized in 2014 with an initial efficiency equal to 12.6%. In simulation, the temperature was considered as a functioning parameter and the evolution of tthe performance of the cell for various thickness of the TCO layer when the external temperature changes is simulated and discussed. The best efficiency of the solar cell based in CZTSSe is obtained with a ZnO thickness equal to 50 nm and low temperature. Based on the considered marketed cell, we show a technological possible increase of the global efficiency achieving 13% by optimization of ZnO based TCO layer.

  16. Greenland Radar Ice Sheet Thickness Measurements

    Data.gov (United States)

    National Aeronautics and Space Administration — Two 150-MHz coherent radar depth sounders were developed and flown over the Greenland ice sheet to obtain ice thickness measurements in support of PARCA...

  17. Effects of buffer thickness on ATW blanket performances

    International Nuclear Information System (INIS)

    Yang, Won Sik

    2001-01-01

    This paper presents the preliminary results of target and buffer design studies for a lead-bismuth eutectic (LBE) cooled accelerator transmutation of waste (ATW) system, aimed at maximizing the source importance while simultaneously reducing the irradiation damage to fuel. Using an 840 MWt LBE cooled ATW design, the effects of buffer thickness on the blanket performances have been studied. Varying the buffer thickness for a given blanket configuration, system performances have been estimated by a series of calculations using MCNPX and REBUS-3 codes. The effects of source importance change are studied by investigating the low-energy (< 20 MeV) neutron source distribution and the equilibrium cycle blanket performance parameters such as fuel inventory, discharge burnup, burnup reactivity loss, and peak fast fluence. As the irradiation damage to fuel, the displacements per atom (dpa), hydrogen production, and helium production rates are evaluated at the buffer and blanket interface where the peak fast fluence occurs. The results show that the damage rates and the source importance increase monotonically as the buffer thickness decreases. Based on a compromise between the competing objectives of increasing the source importance and reducing the damage rates, a buffer thickness of around 20 cm appears to be reasonable

  18. Accelerating Thick Aluminum Liners Using Pulsed Power

    International Nuclear Information System (INIS)

    Kyrala, G.A.; Hammerburg, J.E.; Bowers, D.; Stokes, J.; Morgan, D.V.; Anderson, W.E.; Cochrane, J.C.

    1999-01-01

    The authors have investigated the acceleration of very thick cylindrical aluminum liners using the Pegasus II capacitory bank. These accelerated solid liners will be used to impact other objects at velocities below 1.5 km/sec, allowing one to generate and sustain shocks of a few 100 kilobar for a few microseconds. A cylindrical shell of 1100 series aluminum with an initial inner radius of 23.61 mm, an initial thickness of 3.0 mm, and a height of 20 mm, was accelerated using a current pulse of 7.15 MA peak current and a 7.4 microsecond quarter cycle time. The aluminum shell was imploded within confining copper glide planes with decreasing separation with an inward slope of 8 degrees. At impact with a cylindrical target of diameter 3-cm, the liner was moving at 1.4 km/sec and its thickness increased to 4.5 mm. Radial X-ray radiograms of the liner showed both the liner and the glide plane interface. The curvature of the inner surface of the liner was measured before impact with the 15-mm radius target. The radiograms also showed that the copper glide planes distorted as the liner radius decreased and that some axial stress is induced in the liner. The axial stresses did not affect the inner curvature significantly. Post-shot calculations of the liner behavior indicated that the thickness of the glide plane played a significant role in the distortion of the interface between the liner and the glide plane

  19. Porosity of porcine bladder acellular matrix: impact of ACM thickness.

    Science.gov (United States)

    Farhat, Walid; Chen, Jun; Erdeljan, Petar; Shemtov, Oren; Courtman, David; Khoury, Antoine; Yeger, Herman

    2003-12-01

    The objectives of this study are to examine the porosity of bladder acellular matrix (ACM) using deionized (DI) water as the model fluid and dextran as the indicator macromolecule, and to correlate the porosity to the ACM thickness. Porcine urinary bladders from pigs weighing 20-50 kg were sequentially extracted in detergent containing solutions, and to modify the ACM thickness, stretched bladders were acellularized in the same manner. Luminal and abluminal ACM specimens were subjected to fixed static DI water pressure (10 cm); and water passing through the specimens was collected at specific time interval. While for the macromolecule porosity testing, the diffusion rate and direction of 10,000 MW fluoroescein-labeled dextrans across the ACM specimens mounted in Ussing's chambers were measured. Both experiments were repeated on the thin stretched ACM. In both ACM types, the fluid porosity in both directions did not decrease with increased test duration (3 h); in addition, the abluminal surface was more porous to fluid than the luminal surface. On the other hand, when comparing thin to thick ACM, the porosity in either direction was higher in the thick ACM. Macromolecule porosity, as measured by absorbance, was higher for the abluminal thick ACM than the luminal side, but this characteristic was reversed in the thin ACM. Comparing thin to thick ACM, the luminal side in the thin ACM was more porous to dextran than in the thick ACM, but this characteristic was reversed for the abluminal side. The porcine bladder ACM possesses directional porosity and acellularizing stretched urinary bladders may increase structural density and alter fluid and macromolecule porosity. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 970-974, 2003

  20. Frobenius splitting of thick flag manifolds of Kac-Moody algebras

    OpenAIRE

    Kato, Syu

    2017-01-01

    We explain that the Pl\\"ucker relations provide the defining equations of the thick flag manifold associated to a Kac-Moody algebra. This naturally transplant the result of Kumar-Mathieu-Schwede about the Frobenius splitting of thin flag manifolds to the thick case. As a consequence, we provide a description of the global sections of line bundles of a thick Schubert variety as conjectured in Kashiwara-Shimozono [Duke Math. J. 148 (2009)]. This also yields the existence of a compatible basis o...

  1. Investigation of thick grid plasma switches for thermionic system output voltage

    International Nuclear Information System (INIS)

    Alekseev, N.I.; Kaplan, V.B.; Martsinovski, A.M.

    1992-01-01

    Plasma switches (Cs and Cs-Ba tacitrons PS) with thick grid have grid with thickness more than mesh aperture size. These grids have some advantages as compared with small-scale/1.2/ones. For instance, much more electrical strength. This paper contains the thick-grid investigation results: the grid controls efficiency, the plasma parameters, probe researches of these parameters at conductive state and their variety during the process of quenching. The results showed the thick-grid PS plasma differed from the thin-grid PS significantly at the stationary state as well as by quenching dynamic features

  2. Effect of skin graft thickness on scar development in a porcine burn model.

    Science.gov (United States)

    DeBruler, Danielle M; Blackstone, Britani N; McFarland, Kevin L; Baumann, Molly E; Supp, Dorothy M; Bailey, J Kevin; Powell, Heather M

    2018-06-01

    Animal models provide a way to investigate scar therapies in a controlled environment. It is necessary to produce uniform, reproducible scars with high anatomic and biologic similarity to human scars to better evaluate the efficacy of treatment strategies and to develop new treatments. In this study, scar development and maturation were assessed in a porcine full-thickness burn model with immediate excision and split-thickness autograft coverage. Red Duroc pigs were treated with split-thickness autografts of varying thickness: 0.026in. ("thin") or 0.058in. ("thick"). Additionally, the thin skin grafts were meshed and expanded at 1:1.5 or 1:4 to evaluate the role of skin expansion in scar formation. Overall, the burn-excise-autograft model resulted in thick, raised scars. Treatment with thick split-thickness skin grafts resulted in less contraction and reduced scarring as well as improved biomechanics. Thin skin autograft expansion at a 1:4 ratio tended to result in scars that contracted more with increased scar height compared to the 1:1.5 expansion ratio. All treatment groups showed Matrix Metalloproteinase 2 (MMP2) and Transforming Growth Factor β1 (TGF-β1) expression that increased over time and peaked 4 weeks after grafting. Burns treated with thick split-thickness grafts showed decreased expression of pro-inflammatory genes 1 week after grafting, including insulin-like growth factor 1 (IGF-1) and TGF-β1, compared to wounds treated with thin split-thickness grafts. Overall, the burn-excise-autograft model using split-thickness autograft meshed and expanded to 1:1.5 or 1:4, resulted in thick, raised scars similar in appearance and structure to human hypertrophic scars. This model can be used in future studies to study burn treatment outcomes and new therapies. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  3. Nondestructive testing technology for measurement coatings thickness on material

    International Nuclear Information System (INIS)

    Yang Mingtai; Wu Lunqiang; Zhang Lianping

    2008-01-01

    The principle, applicability range, advantage and disadvantage of electromagnetic, eddy current method, β backscatter method and XRF methods for nondestructive testing coating thickness of material have been reviewed. The relevant apparatus and manufacturers have been summarized. And the application and developmental direction of manufacturers for nondestructive testing coatings thickness has been foreshowed. (authors)

  4. Thin coating thickness determination using radioisotope-excited x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Del Castillo, Lorena A.; Calix, Virginia S.

    2001-01-01

    Three different approaches on thin coating thickness determination using a radioisotope-excited x-ray fluorescence spectrometry were demonstrated and results were compared. A standard of thin layer of gold (Au) on a nickel (Ni) substrate from the US National Bureau of Standards (with a nominal thickness of 0.300505 microns of at least 99.9% Au electrodeposited over 2 nils of Ni) on low carbon steel (1010) was analyzed using a Cd 109-excited XRF system. Au thickness computations were done using the (a) thin standard approach, (b) thick standard approach, and (c) x-ray absorption method (ASTM A754-79 1982). These three methods yielded results within the limit set by the American Society for Testing Materials (ASTM), which is +/-3%. Of the three methods, the thick standard yielded the best result with 0.124% error. (Author)

  5. Multispectral UV imaging for determination of the tablet coating thickness

    DEFF Research Database (Denmark)

    Novikova, Anna; Carstensen, Jens Michael; Zeitler, J. Axel

    2017-01-01

    The applicability of off-line multispectral ultraviolet (UV) imaging in combination with multivariate data analysis was investigated to determine the coating thickness and its distribution on the tablet surface during lab scale coating. The UV imaging results were compared with the weight gain...... measured for each individual tablet and the corresponding coating thickness and its distribution measured by terahertz pulsed imaging (TPI). Three different tablet formulations were investigated, two of which contained UV active tablet cores. Three coating formulations were applied: Aquacoat® ECD (a mainly...... translucent coating) and Eudragit® NE (a turbid coating containing solid particles). It was shown that UV imaging is a fast and non-destructive method to predict individual tablet weight gain as well as coating thickness. The coating thickness distribution profiles determined by UV imaging correlated...

  6. Effective radiation attenuation calibration for breast density: compression thickness influences and correction

    Directory of Open Access Journals (Sweden)

    Thomas Jerry A

    2010-11-01

    Full Text Available Abstract Background Calibrating mammograms to produce a standardized breast density measurement for breast cancer risk analysis requires an accurate spatial measure of the compressed breast thickness. Thickness inaccuracies due to the nominal system readout value and compression paddle orientation induce unacceptable errors in the calibration. Method A thickness correction was developed and evaluated using a fully specified two-component surrogate breast model. A previously developed calibration approach based on effective radiation attenuation coefficient measurements was used in the analysis. Water and oil were used to construct phantoms to replicate the deformable properties of the breast. Phantoms consisting of measured proportions of water and oil were used to estimate calibration errors without correction, evaluate the thickness correction, and investigate the reproducibility of the various calibration representations under compression thickness variations. Results The average thickness uncertainty due to compression paddle warp was characterized to within 0.5 mm. The relative calibration error was reduced to 7% from 48-68% with the correction. The normalized effective radiation attenuation coefficient (planar representation was reproducible under intra-sample compression thickness variations compared with calibrated volume measures. Conclusion Incorporating this thickness correction into the rigid breast tissue equivalent calibration method should improve the calibration accuracy of mammograms for risk assessments using the reproducible planar calibration measure.

  7. On the homogeneity and heterogeneity of cortical thickness profiles in Homo sapiens sapiens.

    Science.gov (United States)

    Koten, Jan Willem; Schüppen, André; Morozova, Maria; Lehofer, Agnes; Koschutnig, Karl; Wood, Guilherme

    2017-12-20

    Cortical thickness has been investigated since the beginning of the 20th century, but we do not know how similar the cortical thickness profiles among humans are. In this study, the local similarity of cortical thickness profiles was investigated using sliding window methods. Here, we show that approximately 5% of the cortical thickness profiles are similarly expressed among humans while 45% of the cortical thickness profiles show a high level of heterogeneity. Therefore, heterogeneity is the rule, not the exception. Cortical thickness profiles of somatosensory homunculi and the anterior insula are consistent among humans, while the cortical thickness profiles of the motor homunculus are more variable. Cortical thickness profiles of homunculi that code for muscle position and skin stimulation are highly similar among humans despite large differences in sex, education, and age. This finding suggests that the structure of these cortices remains well preserved over a lifetime. Our observations possibly relativize opinions on cortical plasticity.

  8. Thickness effect on the microstructure, morphology and optoelectronic properties of ZnS films

    International Nuclear Information System (INIS)

    Prathap, P; Revathi, N; Subbaiah, Y P Venkata; Reddy, K T Ramakrishna

    2008-01-01

    Thin films of ZnS with thicknesses ranging from 100 to 600 nm have been deposited on glass substrates by close spaced thermal evaporation. All the films were grown at the same deposition conditions except the deposition time. The effect of thickness on the physical properties of ZnS films has been studied. The experimental results indicated that the thickness affects the structure, lattice strain, surface morphology and optoelectronic properties of ZnS films significantly. The films deposited at a thickness of 100 nm showed hexagonal structure whereas films of thickness 300 nm or more showed cubic structure. However, coexistence of both cubic and hexagonal structures was observed in the films of 200 nm thickness. The surface roughness of the films showed an increasing trend at higher thicknesses of the films. A blue-shift in the energy band gap along with an intense UV emission band was observed with the decrease of film thickness, which are ascribed to the quantum confinement effect. The behaviour of optical constants such as refractive index and extinction coefficient were analysed. The variation of refractive index and extinction coefficient with thickness was explained on the basis of the contribution from the packing density of the layers. The electrical resistivity as well as the activation energy were evaluated and found to decrease with the increase of film thickness. The thickness had a significant influence on the optical band gap as well as the luminescence intensity

  9. Arctic Sea Ice Freeboard and Thickness

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides measurements of sea ice freeboard and sea ice thickness for the Arctic region. The data were derived from measurements made by from the Ice,...

  10. Improving friction stir welding of blanks of different thicknesses

    Energy Technology Data Exchange (ETDEWEB)

    Fratini, L. [Dipartimento di Tecnologia Meccanica, Produzione e Ingegneria Gestionale, Universita di Palermo, Viale delle Scienze, 90128 Palermo (Italy)], E-mail: abaqus@dtpm.unipa.it; Buffa, G. [Dipartimento di Tecnologia Meccanica, Produzione e Ingegneria Gestionale, Universita di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Shivpuri, R. [Ohio State University, Department of Industrial, Welding and Systems Engineering, 1971 Neil Avenue, 210 Baker Systems, Columbus, Ohio 43210 (United States)

    2007-06-25

    Friction stir welding (FSW) appears to be a promising process even in the welding of blanks of different thicknesses. Actually, such particular tailor welded blanks (TWBs) are usually characterized by a reduction in ductility due to the utilized fusion welding process. In this paper the authors, starting from a preliminary feasibility study, investigate the possibility to improve the mechanical performances of friction stir welded blanks of aluminum alloy with different thicknesses. Both experiments and a FE analyses are developed for a few case studies with different thickness ratios between the blanks. The numerical investigations are performed with the aim to highlight the material temperature distribution during the process in order to determine process conditions for which an almost symmetric thermal flow is obtained in the two blanks of the joint. In this way, a few simple process design rules are derived and verified through experiments. In particular a thickness ratio up to 2 was considered and a joint resistance of about the 80% of the parent material ultimate tensile strength was observed.

  11. Improving friction stir welding of blanks of different thicknesses

    International Nuclear Information System (INIS)

    Fratini, L.; Buffa, G.; Shivpuri, R.

    2007-01-01

    Friction stir welding (FSW) appears to be a promising process even in the welding of blanks of different thicknesses. Actually, such particular tailor welded blanks (TWBs) are usually characterized by a reduction in ductility due to the utilized fusion welding process. In this paper the authors, starting from a preliminary feasibility study, investigate the possibility to improve the mechanical performances of friction stir welded blanks of aluminum alloy with different thicknesses. Both experiments and a FE analyses are developed for a few case studies with different thickness ratios between the blanks. The numerical investigations are performed with the aim to highlight the material temperature distribution during the process in order to determine process conditions for which an almost symmetric thermal flow is obtained in the two blanks of the joint. In this way, a few simple process design rules are derived and verified through experiments. In particular a thickness ratio up to 2 was considered and a joint resistance of about the 80% of the parent material ultimate tensile strength was observed

  12. Film thickness in gas-liquid two-phase flow, (2)

    International Nuclear Information System (INIS)

    Sekoguchi, Kotohiko; Fukano, Toru; Kawakami, Yasushi; Shimizu, Hideo.

    1977-01-01

    The effect of four rectangular obstacles inserted into a circular tube has been studied in gas-liquid two-phase flow. The obstacles are set on the inner wall of the tube, and the ratio of the opening is 0.6. The water film flows partially through the obstacles. The minimum thickness of water film was measured in relation to flow speed. The serious effect of the obstacles was seen against the formation of water film, and drainage under the obstacles and backward flow play important roles. Since water film can flow partially through the obstacles, the film in case of the rectangular obstacles in thicker than that in case of an orifice when the gas flow speed was slower than 5 m/s. However, when the gas flow speed is over 5 m/s, the film thickness was thinner. The minimum film thickness of downstream of the obstacles was almost same as that in case of no obstacle. The minimum film thickness of up stream depends on the location of measurement due to the effect of drainage. (Kato, T.)

  13. Thick-film effects in the oxidation and hydriding of zirconium alloys

    International Nuclear Information System (INIS)

    Johnson, A.B. Jr.

    1989-08-01

    One of the fundamental discoveries involving radiation effects on the oxidation of Zircaloy in low-oxygen aqueous environments is the influence of thick oxide films. Zircaloy oxidation rates in low-oxygen (hydrogen-rich) coolants initially proceed at relatively low rates, often almost uninfluenced by radiation. Marked upturns in oxidation rate have signaled the onset of radiation effects. The radiation effects appear to correlate with a threshold oxide thickness. Results of the test reactor experiments lead to formulation of the Thick-Film Hypothesis: beyond a threshold oxide thickness, radiolysis of water that infiltrates oxide cracks and pores controls the oxidation rate; radiation creates microenvironments inside the oxide film, producing highly oxidizing conditions, that are no longer suppressed by the coolant-borne hydrogen. Upturns in oxidation rate on high-exposure Zircaloy pressure tubes add confirmatory evidence for the thick-film effect. This paper summarizes the early evidence for thick-film behavior, including oxidation and hydriding trends, updates confirmatory evidence from Zircaloy reactor and fuel assembly components, and highlights other observations from the test reactor series that have potential fundamental significance to explanations of radiation effects on Zircaloy. 23 refs., 10 figs

  14. Electrical characteristics of tunneling field-effect transistors with asymmetric channel thickness

    Science.gov (United States)

    Kim, Jungsik; Oh, Hyeongwan; Kim, Jiwon; Meyyappan, M.; Lee, Jeong-Soo

    2017-02-01

    Effects of using asymmetric channel thickness in tunneling field-effect transistors (TFET) are investigated in sub-50 nm channel regime using two-dimensional (2D) simulations. As the thickness of the source side becomes narrower in narrow-source wide-drain (NSWD) TFETs, the threshold voltage (V th) and the subthreshold swing (SS) decrease due to enhanced gate controllability of the source side. The narrow source thickness can make the band-to-band tunneling (BTBT) distance shorter and induce much higher electric field near the source junction at the on-state condition. In contrast, in a TFET with wide-source narrow-drain (WSND), the SS shows almost constant values and the V th slightly increases with narrowing thickness of the drain side. In addition, the ambipolar current can rapidly become larger with smaller thickness on the drain side because of the shorter BTBT distance and the higher electric-field at the drain junction. The on-current of the asymmetric channel TFET is lower than that of conventional TFETs due to the volume limitation of the NSWD TFET and high series resistance of the WSND TFET. The on-current is almost determined by the channel thickness of the source side.

  15. Effect of thickness on silicon solar cell efficiency

    Science.gov (United States)

    Sah, C.-T.; Yamakawa, K. A.; Lutwack, R.

    1982-01-01

    A computer-aided-design study on the dependence of the efficiency peak of a back-surface field solar cell on the concentrations of the recombination and dopant impurities is presented. The illuminated current-voltage characteristics of more than 100 cell designs are obtained using the transmission line circuit model to numerically solve the Shockley equations. Using an AM 1 efficiency of 17% as a target value, it is shown that the efficiency versus thickness dependence has a broad maximum which varies by less than 1% over more than a three-to-one range of cell thicknesses from 30 to 100 microns. An optically reflecting back surface will give only a slight improvement of AM 1 efficiency, about 0.7%, in this thickness range. Attention is given to the dependence of the efficiency on patchiness across the back-surface field low-high junction in thin cells.

  16. MEMS-based thick film PZT vibrational energy harvester

    DEFF Research Database (Denmark)

    Lei, Anders; Xu, Ruichao; Thyssen, Anders

    2011-01-01

    We present a MEMS-based unimorph silicon/PZT thick film vibrational energy harvester with an integrated proof mass. We have developed a process that allows fabrication of high performance silicon based energy harvesters with a yield higher than 90%. The process comprises a KOH etch using a mechan......We present a MEMS-based unimorph silicon/PZT thick film vibrational energy harvester with an integrated proof mass. We have developed a process that allows fabrication of high performance silicon based energy harvesters with a yield higher than 90%. The process comprises a KOH etch using...... a mechanical front side protection of an SOI wafer with screen printed PZT thick film. The fabricated harvester device produces 14.0 μW with an optimal resistive load of 100 kΩ from 1g (g=9.81 m s-2) input acceleration at its resonant frequency of 235 Hz....

  17. Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT

    International Nuclear Information System (INIS)

    Soo, G.; Lau, K.K.; Yik, T.; Kutschera, P.

    2010-01-01

    Aim: To evaluate the impact of different reconstructed section thicknesses on liver lesion detection using multidetector computed tomography (CT). Methods: Fifty-three patients were examined using a 16-section CT machine with axial reconstructions provided at 2.5, 5, 7.5, and 10 mm section thicknesses. Images of different reconstructed section thicknesses from different patients were presented in random order to three independent, blinded radiologists for review at multiple sessions. All images were then reviewed by three radiologists in a common session. Consensus was reached following review of the previous interpretation results and results of follow-up imaging regarding the number of true liver lesions (n = 101) for comparison. Results: Mean detection rates were as follows: 93/101 lesions detected with the 2.5 mm section thickness, 98/101 lesions detected at the 5 mm section thickness, 78/101 lesions detected at the 7.5 mm section thickness, and 54/101 lesions detected at the 10 mm section thickness. Lesions missed at the 2.5 mm section thickness were due to masking by image noise. There was particular difficulty detecting subcapsular lesions and lesions adjacent to fissures or the gall bladder at the 7.5 mm and 10 mm section thicknesses. Conclusion: The optimal reconstructed section thickness for lesion detection in the liver was 5 mm.

  18. Increase in average foveal thickness after internal limiting membrane peeling

    Directory of Open Access Journals (Sweden)

    Kumagai K

    2017-04-01

    Full Text Available Kazuyuki Kumagai,1 Mariko Furukawa,1 Tetsuyuki Suetsugu,1 Nobuchika Ogino2 1Department of Ophthalmology, Kami-iida Daiichi General Hospital, 2Department of Ophthalmology, Nishigaki Eye Clinic, Aichi, Japan Purpose: To report the findings in three cases in which the average foveal thickness was increased after a thin epiretinal membrane (ERM was removed by vitrectomy with internal limiting membrane (ILM peeling.Methods: The foveal contour was normal preoperatively in all eyes. All cases underwent successful phacovitrectomy with ILM peeling for a thin ERM. The optical coherence tomography (OCT images were examined before and after the surgery. The changes in the average foveal (1 mm thickness and the foveal areas within 500 µm from the foveal center were measured. The postoperative changes in the inner and outer retinal areas determined from the cross-sectional OCT images were analyzed.Results: The average foveal thickness and the inner and outer foveal areas increased significantly after the surgery in each of the three cases. The percentage increase in the average foveal thickness relative to the baseline thickness was 26% in Case 1, 29% in Case 2, and 31% in Case 3. The percentage increase in the foveal inner retinal area was 71% in Case 1, 113% in Case 2, and 110% in Case 3, and the percentage increase in foveal outer retinal area was 8% in Case 1, 13% in Case 2, and 18% in Case 3.Conclusion: The increase in the average foveal thickness and the inner and outer foveal areas suggests that a centripetal movement of the inner and outer retinal layers toward the foveal center probably occurred due to the ILM peeling. Keywords: internal limiting membrane, optical coherence tomography, average foveal thickness, epiretinal membrane, vitrectomy

  19. Lead Equivalent Thickness Measurement for Mixed Compositions of Barium Plaster Block

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Nur Shahriza Zainuddin; Mohd Khairusalih Md Zin; Shahrul Azlan Azizan

    2016-01-01

    Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)

  20. Russian River Ice Thickness and Duration

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set consists of river ice thickness measurements, and beginning and ending dates for river freeze-up events from fifty stations in northern Russia. The...

  1. Retrieval of sea ice thickness during Arctic summer using melt pond color

    Science.gov (United States)

    Istomina, L.; Nicolaus, M.; Heygster, G.

    2016-12-01

    The thickness of sea ice is an important climatic variable. Together with the ice concentration, it defines the total sea ice volume, is linked within the climatic feedback mechanisms and affects the Arctic energy balance greatly. During Arctic summer, the sea ice cover changes rapidly, which includes the presence of melt ponds, as well as reduction of ice albedo and ice thickness. Currently available remote sensing retrievals of sea ice thickness utilize data from altimeter, microwave, thermal infrared sensors and their combinations. All of these methods are compromised in summer in the presence of melt. This only leaves in situ and airborne sea ice thickness data available in summer. At the same time, data of greater coverage is needed for assimilation in global circulation models and correct estimation of ice mass balance.This study presents a new approach to estimate sea ice thickness in summer in the presence of melt ponds. Analysis of field data obtained during the RV "Polarstern" cruise ARK27/3 (August - October 2012) has shown a clear connection of ice thickness under melt ponds to their measured spectral albedo and to melt pond color in the hue-saturation-luminance color space from field photographs. An empirical function is derived from the HSL values and applied to aerial imagery obtained during various airborne campaigns. Comparison to in situ ice thickness shows a good correspondence to the ice thickness value retrieved in the melt ponds. A similar retrieval is developed for satellite spectral bands using the connection of the measured pond spectral albedo to the ice thickness within the melt ponds. Correction of the retrieved ice thickness in ponds to derive total thickness of sea ice is discussed. Case studies and application to very high resolution optical data are presented, as well as a concept to transfer the method to satellite data of lower spatial resolution where melt ponds become subpixel features.

  2. Pipe Wall Thickness Monitoring Using Dry-Coupled Ultrasonic Waveguide Technique

    International Nuclear Information System (INIS)

    Cheong, Yong Moo; Kim, Ha Nam; Kim, Hong Pyo

    2012-01-01

    In order to monitor a corrosion or FAC (Flow Accelerated Corrosion) in a pipe, there is a need to measure pipe wall thickness at high temperature. Ultrasonic thickness gauging is the most commonly used non-destructive testing technique for wall thickness measurement. However, current commonly available ultrasonic transducers cannot withstand high temperatures, such as above 200 .deg. C. It is therefore necessary to carry out manual measurements during plant shutdowns. The current method thus reveals several disadvantages: inspection have to be performed during shutdowns with the possible consequences of prolonging down time and increasing production losses, insulation has to be removed and replaced for each manual measurement, and scaffolding has to be installed to inaccessible areas, resulting in considerable cost for interventions. It has been suggested that a structural health monitoring approach with permanently installed ultrasonic thickness gauges could have substantial benefits over current practices. The main reasons why conventional piezoelectric ultrasonic transducers cannot be used at high temperatures are that the piezo-ceramic becomes depolarized at temperature above the Curie temperature and because differential thermal expansion of the substrate, couplant, and piezoelectric materials cause failure. In this paper, a shear horizontal waveguide technique for wall thickness monitoring at high temperature is investigated. Two different designs for contact to strip waveguide are shown and the quality of output signal is compared and reviewed. After a success of acquiring high quality ultrasonic signal, experiment on the wall thickness monitoring at high temperature is planned

  3. Sputtering of Thick Deuterium Films by KeV Electrons

    DEFF Research Database (Denmark)

    Thestrup Nielsen, Birgitte; Svendsen, Winnie Edith; Schou, Jørgen

    1994-01-01

    Sputtering of thick films of solid deuterium up to several μm by keV electrons is reported for the first time. The sputtering yield increases within a narrow range of thicknesses around 1.6 μm by about 2 orders of magnitude for 1.5 keV electrons. A similar behavior has not been observed for ion...

  4. Multispectral UV Imaging for Determination of the Tablet Coating Thickness.

    Science.gov (United States)

    Novikova, Anna; Carstensen, Jens M; Zeitler, J Axel; Rades, Thomas; Leopold, Claudia S

    2017-06-01

    The applicability of off-line multispectral UV imaging in combination with multivariate data analysis was investigated to determine the coating thickness and its distribution on the tablet surface during lab-scale coating. The UV imaging results were compared with the weight gain measured for each individual tablet and the corresponding coating thickness and its distribution measured by terahertz pulsed imaging (TPI). Three different tablet formulations were investigated, 2 of which contained UV-active tablet cores. Three coating formulations were applied: Aquacoat® ECD (a mainly translucent coating) and Eudragit® NE (a turbid coating containing solid particles). It was shown that UV imaging is a fast and nondestructive method to predict individual tablet weight gain as well as coating thickness. The coating thickness distribution profiles determined by UV imaging correlated to the results of the TPI measurements. UV imaging appears to hold a significant potential as a process analytical technology tool for determination of the tablet coating thickness and its distribution resulting from its high measurement speed, high molar absorptivity, and a high scattering coefficient, in addition to relatively low costs. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  5. A study on fracture characteristic of aluminum foam by thickness

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Teng [Dept. of Mechanical Engineering, Graduate School, Kongju National University, Kongju (Korea, Republic of); Cho, Jae Ung [Div. of Mechanical and Automotive Engineering, Kongju National University, Kongju (Korea, Republic of)

    2015-10-15

    Because foam metal has the excellent physical characteristics and mechanical performance, they are applied extensively into a lot of advanced technology areas. The aluminum foam with closed cell is one of the foam metals. It is applied widely into automobile and airplane because of the excellent absorption performance of impact energy. In this study, the mechanical characteristics by thickness was analyzed through the impact experiment of closed-cell aluminum foam, and the simulation analysis was performed for the verification. As the simulation analysis method, a finite-element analysis was carried under the same boundary conditions as the experiment by using ANSYS. By comparing with the results of experiment and simulation, it was thought that the case of thickness of 20 mm was the most efficient of among the cases of thicknesses of 10 mm, 20 mm and 30 mm. At the case of thickness of 20 mm, the absorption energy by comparing with the specimen thickness is shown to become the most among three models. By using the result of this study, it is thought that it can apply the material necessary to develop the mechanical structure with aluminum foam.

  6. Optimization of Plastic Scintillator Thicknesses for Online Beta Detection in Mixed Fields

    Energy Technology Data Exchange (ETDEWEB)

    Pourtangestani, K.; Machrafi, R. [University of Ontario Institute of Technology, Oshawa, ON (Canada)

    2013-07-15

    For efficient beta detection in a mixed beta-gamma field, Monte Carlo simulation models have been developed to optimize the thickness of a plastic scintillator used in whole body monitor. The simulation has been performed using MCNP/X code and different thicknesses of plastic scintillators ranging from 150 to 600 {mu}m have been used. The relationship between the thickness of the scintillator and the efficiency of the detector has been analysed. For 150 {mu}m thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 {mu}m to 500 {mu}m has been found to be an optimum thickness for better beta detection efficiency in the presence of low energy gamma ray. (author)

  7. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography

    Directory of Open Access Journals (Sweden)

    Nikoo Hamzeh

    2015-12-01

    Full Text Available AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT in comparison with A-scan ultrasonography (A-scan US. METHODS: There were 218 adult subjects (218 eyes aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III. Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA. The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74. Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001, and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001 CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.

  8. Versatile technique for assessing thickness of 2D layered materials by XPS

    Science.gov (United States)

    Zemlyanov, Dmitry Y.; Jespersen, Michael; Zakharov, Dmitry N.; Hu, Jianjun; Paul, Rajib; Kumar, Anurag; Pacley, Shanee; Glavin, Nicholas; Saenz, David; Smith, Kyle C.; Fisher, Timothy S.; Voevodin, Andrey A.

    2018-03-01

    X-ray photoelectron spectroscopy (XPS) has been utilized as a versatile method for thickness characterization of various two-dimensional (2D) films. Accurate thickness can be measured simultaneously while acquiring XPS data for chemical characterization of 2D films having thickness up to approximately 10 nm. For validating the developed technique, thicknesses of few-layer graphene (FLG), MoS2 and amorphous boron nitride (a-BN) layer, produced by microwave plasma chemical vapor deposition (MPCVD), plasma enhanced chemical vapor deposition (PECVD), and pulsed laser deposition (PLD) respectively, were accurately measured. The intensity ratio between photoemission peaks recorded for the films (C 1s, Mo 3d, B 1s) and the substrates (Cu 2p, Al 2p, Si 2p) is the primary input parameter for thickness calculation, in addition to the atomic densities of the substrate and the film, and the corresponding electron attenuation length (EAL). The XPS data was used with a proposed model for thickness calculations, which was verified by cross-sectional transmission electron microscope (TEM) measurement of thickness for all the films. The XPS method determines thickness values averaged over an analysis area which is orders of magnitude larger than the typical area in cross-sectional TEM imaging, hence provides an advanced approach for thickness measurement over large areas of 2D materials. The study confirms that the versatile XPS method allows rapid and reliable assessment of the 2D material thickness and this method can facilitate in tailoring growth conditions for producing very thin 2D materials effectively over a large area. Furthermore, the XPS measurement for a typical 2D material is non-destructive and does not require special sample preparation. Therefore, after XPS analysis, exactly the same sample can undergo further processing or utilization.

  9. Benefits of the Multiple Echo Technique for Ultrasonic Thickness Testing

    Energy Technology Data Exchange (ETDEWEB)

    Elder, J.; Vandekamp, R.

    2011-02-10

    Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.

  10. Measurement of the thickness of thin films by backscattered protons

    International Nuclear Information System (INIS)

    Samaniego, L.E.Q.

    1976-07-01

    The method of backscattered protons has been used to measure the thickness of thin films. A monoenergetic beam of protons is directed on the film to be measured and the backscattered protons are detected with a particle detector. The film thickness is calculated from the energy spectrum of the protons. In the case of films consisting of several layers of elements with well separated atomic masses, it is possible to separate the spectra of protons scattered from the different elements, permitting a measurement of the thicknesses of the different layers. The method consists of calculating the energy loss of the protons throughout their trajectory, from the point of incidence on the film to the final detection. Thicknesses were measured for the following film combinations: gold on mylar, chromium on mylar, gold on chromium on mylar, and pure mylar. (Author) [pt

  11. Terahertz thickness determination with interferometric vibration correction for industrial applications.

    Science.gov (United States)

    Pfeiffer, Tobias; Weber, Stefan; Klier, Jens; Bachtler, Sebastian; Molter, Daniel; Jonuscheit, Joachim; Von Freymann, Georg

    2018-05-14

    In many industrial fields, like automotive and painting industry, the thickness of thin layers is a crucial parameter for quality control. Hence, the demand for thickness measurement techniques continuously grows. In particular, non-destructive and contact-free terahertz techniques access a wide range of thickness determination applications. However, terahertz time-domain spectroscopy based systems perform the measurement in a sampling manner, requiring fixed distances between measurement head and sample. In harsh industrial environments vibrations of sample and measurement head distort the time-base and decrease measurement accuracy. We present an interferometer-based vibration correction for terahertz time-domain measurements, able to reduce thickness distortion by one order of magnitude for vibrations with frequencies up to 100 Hz and amplitudes up to 100 µm. We further verify the experimental results by numerical calculations and find very good agreement.

  12. Brain cortical thickness in male adolescents with serious substance use and conduct problems.

    Science.gov (United States)

    Chumachenko, Serhiy Y; Sakai, Joseph T; Dalwani, Manish S; Mikulich-Gilbertson, Susan K; Dunn, Robin; Tanabe, Jody; Young, Susan; McWilliams, Shannon K; Banich, Marie T; Crowley, Thomas J

    2015-01-01

    Adolescents with substance use disorder (SUD) and conduct problems exhibit high levels of impulsivity and poor self-control. Limited work to date tests for brain cortical thickness differences in these youths. To investigate differences in cortical thickness between adolescents with substance use and conduct problems and controls. We recruited 25 male adolescents with SUD, and 19 male adolescent controls, and completed structural 3T magnetic resonance brain imaging. Using the surface-based morphometry software FreeSurfer, we completed region-of-interest (ROI) analyses for group cortical thickness differences in left, and separately right, inferior frontal gyrus (IFG), orbitofrontal cortex (OFC) and insula. Using FreeSurfer, we completed whole-cerebrum analyses of group differences in cortical thickness. Versus controls, the SUD group showed no cortical thickness differences in ROI analyses. Controlling for age and IQ, no regions with cortical thickness differences were found using whole-cerebrum analyses (though secondary analyses co-varying IQ and whole-cerebrum cortical thickness yielded a between-group cortical thickness difference in the left posterior cingulate/precuneus). Secondary findings showed that the SUD group, relative to controls, demonstrated significantly less right > left asymmetry in IFG, had weaker insular-to-whole-cerebrum cortical thickness correlations, and showed a positive association between conduct disorder symptom count and cortical thickness in a superior temporal gyrus cluster. Functional group differences may reflect a more nuanced cortical morphometric difference than ROI cortical thickness. Further investigation of morphometric differences is needed. If replicable findings can be established, they may aid in developing improved diagnostic or more targeted treatment approaches.

  13. Thickness dependence of effective critical exponents in three-dimensional Ising plates

    International Nuclear Information System (INIS)

    Marques, M.I.; Gonzalo, J.A.

    2000-01-01

    Phase transitions in ising plates of equal area and different thickness have been studied by the Monte Carlo approach. The evolution of the critical temperature and of the effective critical exponents with the thickness of the lattice has been numerically determined. The thickness dependence of the maximum value of the effective critical exponents is well described by an exponential decay towards the respective three-dimensional value. (author)

  14. Relationship between Body Composition and Pulmonary Function in Early Adult Life: A Cross-Sectional Analysis Nested in Two Birth Cohort Studies.

    Directory of Open Access Journals (Sweden)

    Paula Duarte de Oliveira

    Full Text Available Overweight/obesity has been reported to worsen pulmonary function (PF. This study aimed to examine the association between PF and several body composition (BC measures in two population-based cohorts.We performed a cross-sectional analysis of individuals aged 18 and 30 years from two Pelotas Birth Cohorts in southern Brazil. PF was assessed by spirometry. Body measures that were collected included body mass index, waist circumference, skinfold thickness, percentages of total and segmented (trunk, arms and legs fat mass (FM and total fat-free mass (FFM. FM and FFM were measured by air-displacement plethysmography (BODPOD and by dual-energy x-ray absorptiometry (DXA. Associations were verified through linear regressions stratified by sex, and adjusted for weight, height, skin color, and socioeconomic, behavioral, and perinatal variables.A total of 7347 individuals were included in the analyses (3438 and 3909 at 30 and 18 years, respectively. Most BC measures showed a significant positive association between PF and FFM, and a negative association with FM. For each additional percentage point of FM, measured by BOD POD, the forced vital capacity regression coefficient adjusted by height, weight and skin color, at 18 years, was -33 mL (95% CI -38, -29 and -26 mL (95% CI -30, -22, and -30 mL (95% CI -35, -25 and -19 mL (95% CI -23, -14 at 30 years, in men and women, respectively. All the BOD POD regression coefficients for FFM were the same as for the FM coefficients, but in a positive trend (p<0.001 for all associations.All measures that distinguish FM from FFM (skinfold thickness-FM estimation-BOD POD, total and segmental DXA measures-FM and FFM proportions showed negative trends in the association of FM with PF for both ages and sexes. On the other hand, FFM showed a positive association with PF.

  15. Relationship between Body Composition and Pulmonary Function in Early Adult Life: A Cross-Sectional Analysis Nested in Two Birth Cohort Studies.

    Science.gov (United States)

    Oliveira, Paula Duarte de; Wehrmeister, Fernando C; Pérez-Padilla, Rogelio; Gonçalves, Helen; Assunção, Maria Cecília F; Horta, Bernardo Lessa; Gigante, Denise P; Barros, Fernando C; Menezes, Ana Maria Baptista

    Overweight/obesity has been reported to worsen pulmonary function (PF). This study aimed to examine the association between PF and several body composition (BC) measures in two population-based cohorts. We performed a cross-sectional analysis of individuals aged 18 and 30 years from two Pelotas Birth Cohorts in southern Brazil. PF was assessed by spirometry. Body measures that were collected included body mass index, waist circumference, skinfold thickness, percentages of total and segmented (trunk, arms and legs) fat mass (FM) and total fat-free mass (FFM). FM and FFM were measured by air-displacement plethysmography (BODPOD) and by dual-energy x-ray absorptiometry (DXA). Associations were verified through linear regressions stratified by sex, and adjusted for weight, height, skin color, and socioeconomic, behavioral, and perinatal variables. A total of 7347 individuals were included in the analyses (3438 and 3909 at 30 and 18 years, respectively). Most BC measures showed a significant positive association between PF and FFM, and a negative association with FM. For each additional percentage point of FM, measured by BOD POD, the forced vital capacity regression coefficient adjusted by height, weight and skin color, at 18 years, was -33 mL (95% CI -38, -29) and -26 mL (95% CI -30, -22), and -30 mL (95% CI -35, -25) and -19 mL (95% CI -23, -14) at 30 years, in men and women, respectively. All the BOD POD regression coefficients for FFM were the same as for the FM coefficients, but in a positive trend (pFFM (skinfold thickness-FM estimation-BOD POD, total and segmental DXA measures-FM and FFM proportions) showed negative trends in the association of FM with PF for both ages and sexes. On the other hand, FFM showed a positive association with PF.

  16. Adherence to the Mediterranean diet during pregnancy and offspring adiposity and cardiometabolic traits in childhood.

    Science.gov (United States)

    Chatzi, L; Rifas-Shiman, S L; Georgiou, V; Joung, K E; Koinaki, S; Chalkiadaki, G; Margioris, A; Sarri, K; Vassilaki, M; Vafeiadi, M; Kogevinas, M; Mantzoros, C; Gillman, M W; Oken, E

    2017-08-01

    In adults, adherence to the Mediterranean diet has been inversely associated with cardiovascular risk, but the extent to which diet in pregnancy is associated with offspring adiposity is unclear. We aimed to investigate the association between adherence to Mediterranean diet in pregnancy and offspring cardiometabolic traits in two pregnancy cohorts. We studied 997 mother-child pairs from Project Viva in Massachusetts, USA, and 569 pairs from the Rhea study in Crete, Greece. We estimated adherence to the Mediterranean diet with an a priori defined score (MDS) of nine foods and nutrients (0 to 9). We measured child weight, height, waist circumference, skin-fold thicknesses, blood pressure, and blood levels of lipids, c-reactive protein and adipokines in mid-childhood (median 7.7 years) in Viva, and in early childhood (median 4.2 years) in Rhea. We calculated cohort-specific effects and pooled effects estimates with random-effects models for cohort and child age. In Project Viva, the mean (SD, standard deviation) MDS was 2.7 (1.6); in Rhea it was 3.8 (1.7). In the pooled analysis, for each 3-point increment in the MDS, offspring BMI z-score was lower by 0.14 units (95% CI, -0.15 to -0.13), waist circumference by 0.39 cm (95% CI, -0.64 to -0.14), and the sum of skin-fold thicknesses by 0.63 mm (95% CI, -0.98 to -0.28). We also observed lower offspring systolic (-1.03 mmHg; 95% CI, -1.65 to -0.42) and diastolic blood pressure (-0.57 mmHg; 95% CI, -0.98 to -0.16). Greater adherence to Mediterranean diet during pregnancy may protect against excess offspring cardiometabolic risk. © 2017 World Obesity Federation.

  17. Polylactic acid vs. polyacrylamide hydrogel for treatment of facial lipoatrophy: a randomized controlled trial [Agence Nationale de Recherches sur le SIDA et les Hépatites Virales (ANRS) 132 SMILE].

    Science.gov (United States)

    Lafaurie, M; Dolivo, M; Girard, P-M; May, T; Bouchaud, O; Carbonnel, E; Madelaine, I; Loze, B; Porcher, R; Molina, J-M

    2013-08-01

    The aim of the study was to demonstrate the noninferiority of polyacrylamide hydrogel (PH) vs. polylactic acid (PLA) for the treatment of facial lipoatrophy in HIV-infected adults. A randomized, blinded, multicentre, noninferiority 96-week study was carried out. Patients with facial lipoatrophy were randomly assigned to receive intradermal injections with PH or PLA, and were blinded to the filler. The primary efficacy endpoint was patient satisfaction at week 48 assessed using a visual analogue scale score (VAS). Secondary efficacy end-points included cheek thickness and skin-fold, lipoatrophy grading and quality of life. Safety was assessed by the reporting of adverse events. A total of 148 patients were included in the study; 93% were men, the median age was 47 years, the median CD4 count was 528 cells/μL, and the median duration of antiretroviral therapy was 12 years. Mean VAS increased from 2.8 at baseline to 7.1 and 7.5 in the PLA and PH arms, respectively, at week 48 (P=0.0002 for noninferiority) and was sustained at week 96 (6.7 and 7.9 in the PLA and PH arms, respectively; P=0.003 for noninferiority). Cheek thickness and skin-fold increases and lipoatrophy improvement were similar in the two arms. Quality of life remained unchanged or improved depending on the questionnaire used. In injected patients, subcutaneous nodules emerged in 28 (41%) and 26 (37%) patients in the PLA and PH arms, respectively (P=0.73). Four patients in the PH arm developed severe inflammatory nodules, a median of 17 months after the last injection. PH and PLA have similar efficacies in the treatment of facial lipoatrophy, but PH may be associated with more delayed inflammatory nodules. © 2013 British HIV Association.

  18. Menstrual Changes in Body Composition of Female Athletes.

    Science.gov (United States)

    Stachoń, Aleksandra Jadwiga

    2016-06-01

    The aim of the study was to determine whether the tendencies and scope of changes in body mass, body composition and body girths across the menstrual cycle were similar or different in women of different body build. Anthropometric examinations were carried out in a group of 40 naturally regularly menstruated females practicing team sports (aged 19-21, B-v 169.3+/-6.4 cm, body mass 59.6+/-7.0 kg), in the follicular, periovulatory and luteal phases of the menstrual cycle. The phases were determined on the basis of data from two consecutive menstrual cycles taking into account the cycle’s length. To establish the type of body build, Body Mass Index, hydration status and skinfold thickness were measured. For a statistical analysis, a multiple comparisons with multiple confidence intervals were applied. The increase in body mass between the follicular and the luteal phases was observed in all groups of women, the biggest gain was recorded in slim women, who in the luteal phase weighted 0.8 kg more. The amount of fat mass increased significantly across the menstrual cycle only in more hydrated (by about 0.66 kg) and slim women (by about 0.54 kg). Significant changes between consecutive phases of the menstrual cycle in waist and hip girths, and suprailiac skinfold thickness in some groups of women also indicate influence of fatness and hydration status and slenderness. In view of the presented results, the body build seems important for an analysis of the pattern of each component’s changes across the menstrual cycle, especially for female athletes. Certain changes can be seen only in some groups of women, therefore somatic features can be considered as a predictor of the intensity of changes.

  19. Predictive capacity of anthropometric indicators for dyslipidemia screening in children and adolescents.

    Science.gov (United States)

    Quadros, Teresa Maria Bianchini; Gordia, Alex Pinheiro; Silva, Rosane Carla Rosendo; Silva, Luciana Rodrigues

    2015-01-01

    To analyze the predictive capacity of anthropometric indicators and their cut-off values for dyslipidemia screening in children and adolescents. This was a cross-sectional study involving 1139 children and adolescents, of both sexes, aged 6-18 years. Body weight, height, waist circumference, subscapular, and triceps skinfold thickness were measured. The body mass index and waist-to-height ratio were calculated. Children and adolescents exhibiting at least one of the following lipid alterations were defined as having dyslipidemia: elevated total cholesterol, low high-density lipoprotein, elevated low-density lipoprotein, and high triglyceride concentration. A receiver operating characteristic curve was constructed and the area under the curve, sensitivity, and specificity was calculated for the parameters analyzed. The prevalence of dyslipidemia was 62.1%. The waist-to-height ratio, waist circumference, subscapular, body mass index, and triceps skinfold thickness, in this order, presented the largest number of significant accuracies, ranging from 0.59 to 0.78. The associations of the anthropometric indicators with dyslipidemia were stronger among adolescents than among children. Significant differences between accuracies of the anthropometric indicators were only observed by the end of adolescence; the accuracy of waist-to-height ratio was higher than that of subscapular (p=0.048) for females, and the accuracy of waist circumference was higher than that of subscapular (p=0.029) and body mass index (p=0.012) for males. In general, the cut-off values of the anthropometric predictors of dyslipidemia increased with age, except for waist-to-height ratio. Sensitivity and specificity varied substantially between anthropometric indicators, ranging from 75.6 to 53.5 and from 75.0 to 50.0, respectively. The anthropometric indicators studied had little utility as screening tools for dyslipidemia, especially in children. Copyright © 2015 Sociedade Brasileira de Pediatria

  20. Effect of mining thickness on abutment pressure of working face

    Energy Technology Data Exchange (ETDEWEB)

    Xie Guang-xiang; Wang Lei [Anhui University of Science and Technology, Huainan (China). Academy of Energy Sources and Security

    2008-04-15

    The distribution of the abutment pressure on the advancing front and on side of the working face was analyzed. Results show that the distribution of abutment pressure correlates with the thickness of the coal seam. The size of the abutment pressure peak is inversely proportional to the first mining thickness and the distance between peak and working face is proportional to the first mining thickness; that is to say the peak intensity falls as soon as the distribution range spreads. The distribution of side abutment pressure correlates somewhat with time. 6 refs.

  1. Reliability assessment for thickness measurements of pipe wall using probability of detection

    International Nuclear Information System (INIS)

    Nakamoto, Hiroyuki; Kojima, Fumio; Kato, Sho

    2013-01-01

    This paper proposes a reliability assessment method for thickness measurements of pipe wall using probability of detection (POD). Thicknesses of pipes are measured by qualified inspectors with ultrasonic thickness gauges. The inspection results are affected by human factors of the inspectors and include some errors, because the inspectors have different experiences and frequency of inspections. In order to ensure reliability for inspection results, first, POD evaluates experimental results of pipe-wall thickness inspection. We verify that the results have differences depending on inspectors including qualified inspectors. Second, two human factors that affect POD are indicated. Finally, it is confirmed that POD can identify the human factors and ensure reliability for pipe-wall thickness inspections. (author)

  2. Electroplated thick-film cobalt platinum permanent magnets

    International Nuclear Information System (INIS)

    Oniku, Ololade D.; Qi, Bin; Arnold, David P.

    2016-01-01

    The material and magnetic properties of multi-micron-thick (up to 6 μm) L1 0 CoPt magnetic films electroplated onto silicon substrates are investigated as candidate materials for integration in silicon-based microsystems. The influence of various process conditions on the structure and magnetic properties of electroplated CoPt thick-films is studied in order to better understand the complex process/structure/property relationships associated with the electroplated films. Process variables studied here include different seed layers, electroplating current densities (ranging from 25–200 mA/cm 2 ), deposition times (up to 60 min), and post-deposition annealing times and temperatures. Analyses include film morphology, film thickness, composition, surface roughness, grain size, phase volume fractions, and L1 0 ordering parameter. Key correlations are found relating process and structure variations to the extrinsic magnetic properties (remanence, coercivity, squareness, and energy product). Strong hard magnetic properties (B r ~0.8 T, H ci ~800 kA/m, squareness close to 0.9, and BH max of 100 kJ/m 3 ) are obtained for films deposited on Si/TiN/Ti/Cu at current densities of 100 mA/cm 2 , pH of 7, and subsequently annealed at 675 °C for 30 min. - Highlights: • CoPt films plated up to 6 μm thick on silicon substrates. • A1 to L1 0 phase transformation by annealing in forming gas. • Various process–structure–property relationships explored. • Key results: B r ~0.8 T, H ci ~800 kA/m, squareness 0.9, and BH max ~100 kJ/m 3 .

  3. Duodenal endoscopic full-thickness resection (with video).

    Science.gov (United States)

    Schmidt, Arthur; Meier, Benjamin; Cahyadi, Oscar; Caca, Karel

    2015-10-01

    Endoscopic resection of duodenal non-lifting adenomas and subepithelial tumors is challenging and harbors a significant risk of adverse events. We report on a novel technique for duodenal endoscopic full-thickness resection (EFTR) by using an over-the-scope device. Data of 4 consecutive patients who underwent duodenal EFTR were analyzed retrospectively. Main outcome measures were technical success, R0 resection, histologic confirmation of full-thickness resection, and adverse events. Resections were done with a novel, over-the-scope device (full-thickness resection device, FTRD). Four patients (median age 60 years) with non-lifting adenomas (2 patients) or subepithelial tumors (2 patients) underwent EFTR in the duodenum. All lesions could be resected successfully. Mean procedure time was 67.5 minutes (range 50-85 minutes). Minor bleeding was observed in 2 cases; blood transfusions were not required. There was no immediate or delayed perforation. Mean diameter of the resection specimen was 28.3 mm (range 22-40 mm). Histology confirmed complete (R0) full-thickness resection in 3 of 4 cases. To date, 2-month endoscopic follow-up has been obtained in 3 patients. In all cases, the over-the-scope clip was still in place and could be removed without adverse events; recurrences were not observed. EFTR in the duodenum with the FTRD is a promising technique that has the potential to spare surgical resections. Modifications of the device should be made to facilitate introduction by mouth. Prospective studies are needed to further evaluate efficacy and safety for duodenal resections. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  4. Thickness and fit of mouthguards according to heating methods.

    Science.gov (United States)

    Mizuhashi, Fumi; Koide, Kaoru; Takahashi, Mutsumi

    2014-02-01

    The purpose of this study was to examine the difference in the thickness and fit of mouthguards made by four different heating methods of the mouthguard sheet material. A Sports Mouthguard(®) of 3.8-mm thickness was used in this study. Four heating methods were performed. In one method, the sheet was heated only one side. In the other methods, one side of the sheet was heated first until the center of the sheet was displaced by 0.5 cm, 1.0 cm, and 1.5 cm from the baseline, and then turned upside down and heated. The sheets were adapted using a vacuum former when the heated sheets hung 1.5 cm from the baseline. We measured the thickness and fit of the mouthguard at the areas of the central incisor and first molar. The difference in thickness at the central incisor and first molar regions was analyzed by two-way anova. The difference in fit with different heating methods was analyzed by one-way anova. The results showed that the thickness of the mouthguard differed in the central incisor and first molar areas (P heating methods. The fit of the mouthguard at the central incisor and first molar areas was significantly different among the heating methods (P heated surface of the sheet contacted the surface of the working model. This finding may help to fabricate accurate mouthguards. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Relationship between Outer Retinal Layers Thickness and Visual Acuity in Diabetic Macular Edema

    Directory of Open Access Journals (Sweden)

    Raymond L. M. Wong

    2015-01-01

    Full Text Available Purpose. To investigate the correlation of outer retinal layers (ORL thickness and visual acuity (VA in patients with diabetic macular edema (DME. Methods. Consecutive DME patients seen at the Retina Clinic of The University of Hong Kong were recruited for OCT assessment. The ORL thickness was defined as the distance between external limiting membrane (ELM and retinal pigment epithelium (RPE at the foveal center. The correlation between total retinal thickness, ORL thickness, and vision was calculated. Results. 78 patients with DME were recruited. The mean age was 58.1 years (±11.5 years and their mean visual acuity measured with Snellen chart was 0.51 (±0.18. The correlation coefficient between total retinal thickness and visual acuity was 0.34 (P < 0.001 whereas the correlation coefficient was 0.65 between ORL thickness and visual acuity (P < 0.001. Conclusion. ORL thickness correlates better with vision than the total retinal thickness. It is a novel OCT parameter in the assessment of DME. Moreover, it could be a potential long term visual prognostic factor for patients with DME.

  6. Experimental Influences in the Accurate Measurement of Cartilage Thickness in MRI.

    Science.gov (United States)

    Wang, Nian; Badar, Farid; Xia, Yang

    2018-01-01

    Objective To study the experimental influences to the measurement of cartilage thickness by magnetic resonance imaging (MRI). Design The complete thicknesses of healthy and trypsin-degraded cartilage were measured at high-resolution MRI under different conditions, using two intensity-based imaging sequences (ultra-short echo [UTE] and multislice-multiecho [MSME]) and 3 quantitative relaxation imaging sequences (T 1 , T 2 , and T 1 ρ). Other variables included different orientations in the magnet, 2 soaking solutions (saline and phosphate buffered saline [PBS]), and external loading. Results With cartilage soaked in saline, UTE and T 1 methods yielded complete and consistent measurement of cartilage thickness, while the thickness measurement by T 2 , T 1 ρ, and MSME methods were orientation dependent. The effect of external loading on cartilage thickness is also sequence and orientation dependent. All variations in cartilage thickness in MRI could be eliminated with the use of a 100 mM PBS or imaged by UTE sequence. Conclusions The appearance of articular cartilage and the measurement accuracy of cartilage thickness in MRI can be influenced by a number of experimental factors in ex vivo MRI, from the use of various pulse sequences and soaking solutions to the health of the tissue. T 2 -based imaging sequence, both proton-intensity sequence and quantitative relaxation sequence, similarly produced the largest variations. With adequate resolution, the accurate measurement of whole cartilage tissue in clinical MRI could be utilized to detect differences between healthy and osteoarthritic cartilage after compression.

  7. The crustal thickness of Australia

    Science.gov (United States)

    Clitheroe, G.; Gudmundsson, O.; Kennett, B.L.N.

    2000-01-01

    We investigate the crustal structure of the Australian continent using the temporary broadband stations of the Skippy and Kimba projects and permanent broadband stations. We isolate near-receiver information, in the form of crustal P-to-S conversions, using the receiver function technique. Stacked receiver functions are inverted for S velocity structure using a Genetic Algorithm approach to Receiver Function Inversion (GARFI). From the resulting velocity models we are able to determine the Moho depth and to classify the width of the crust-mantle transition for 65 broadband stations. Using these results and 51 independent estimates of crustal thickness from refraction and reflection profiles, we present a new, improved, map of Moho depth for the Australian continent. The thinnest crust (25 km) occurs in the Archean Yilgarn Craton in Western Australia; the thickest crust (61 km) occurs in Proterozoic central Australia. The average crustal thickness is 38.8 km (standard deviation 6.2 km). Interpolation error estimates are made using kriging and fall into the range 2.5-7.0 km. We find generally good agreement between the depth to the seismologically defined Moho and xenolith-derived estimates of crustal thickness beneath northeastern Australia. However, beneath the Lachlan Fold Belt the estimates are not in agreement, and it is possible that the two techniques are mapping differing parts of a broad Moho transition zone. The Archean cratons of Western Australia appear to have remained largely stable since cratonization, reflected in only slight variation of Moho depth. The largely Proterozoic center of Australia shows relatively thicker crust overall as well as major Moho offsets. We see evidence of the margin of the contact between the Precambrian craton and the Tasman Orogen, referred to as the Tasman Line. Copyright 2000 by the American Geophysical Union.

  8. Normalization of Impact Energy by Laminate Thickness for Compression After Impact Testing

    Science.gov (United States)

    Nettles, A. T.; Hromisin, S. M.

    2013-01-01

    The amount of impact energy used to damage a composite laminate is a critical parameter when assessing residual strength properties. The compression after impact (CAI) strength of impacted laminates is dependent upon how thick the laminate is and this has traditionally been accounted for by normalizing (dividing) the impact energy by the laminate's thickness. However, when comparing CAI strength values for a given lay-up sequence and fiber/resin system, dividing the impact energy by the specimen thickness has been noted by the author to give higher CAI strength values for thicker laminates. A study was thus undertaken to assess the comparability of CAI strength data by normalizing the impact energy by the specimen thickness raised to a power to account for the higher strength of thicker laminates. One set of data from the literature and two generated in this study were analyzed by dividing the impact energy by the specimen thickness to the 1, 1.5, 2, and 2.5 powers. Results show that as laminate thickness and damage severity decreased, the value which the laminate thickness needs to be raised to in order to yield more comparable CAI data increases.

  9. Effect of boundary layer thickness on the flow characteristics around a rectangular prism

    International Nuclear Information System (INIS)

    Ji, Ho Seong; Kim, Kyung Chun

    2001-01-01

    Effect of boundary layer thickness on the flow characteristics around a rectangular prism has been investigated by using a PIV(Particle Image Velocimetry) technique. Three different boundary layers (thick, medium and thin) were generated in the atmospheric boundary layer wind tunnel at Pusan National University. The thick boundary layer having 670mm thickness was generated by using spires and roughness elements. The medium thickness of boundary layer(δ=270mm) was the natural turbulent boundary layer at the test section with fully long developing length(18m). The thin boundary layer with 36.5mm thickness was generated by on a smooth panel elevated 70cm from the wind tunnel floor. The Reynolds number based on the free stream velocity and the height of the model was 7.9X10 3 . The mean velocity vector fields and turbulent kinetic energy distribution were measured and compared. The effect of boundary layer thickness is clearly observed not only in the length of separation bubble but also in the reattachment points. The thinner boundary layer thickness, the higher turbulent kinetic energy peak around the model roof. It is strongly recommended that the height ratio between model and approaching boundary layer thickness should be a major parameter

  10. Long-term changes in subfoveal choroidal thickness and central macula thickness after Nd:YAG laser capsulotomy.

    Science.gov (United States)

    Yilmaz, Tolga; Yilmaz, Ahu

    2017-08-01

    To evaluate changes in central macula thickness (CMT), subfoveal choroid thickness (SCT), and intraocular pressure (IOP) before and after neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy. 42 eyes of 42 patients who underwent Nd:YAG laser capsulotomy were included in this prospective study. CMT, SCT, and IOP were evaluated preoperatively and at postoperative week 1 and postoperative months 1, 3, 6, and 12. CMT was 238.1 ± 27.6 μm (mean ± SD) preoperatively, then 239.7 ± 29.8, 241.3 ± 28.7, 242.7 ± 27.2, 238.8 ± 23.7, and 238.3 ± 21.7 μm at postoperative week 1 and months 1, 3, 6, and 12, respectively. SCT was 263.3 ± 21.6 μm preoperatively, and 265.5 ± 24.8, 266.2 ± 25.7, 267.1 ± 26.3, 269.1 ± 24.2, and 269.9 ± 21.4 μm at postoperative week 1 and months 1, 3, 6, and 12, respectively. There were no significant differences between preoperative and postoperative results for CMT, SCT, or IOP (all p > 0.05). Although there were slight changes in choroid thickness in the long term, treatment of posterior capsule opacification with a low-energy Nd:YAG laser is a safe procedure that increases visual acuity without creating a significant increase in IOP, CMT, and SCT.

  11. Evaluation of retinal nerve fiber layer thickness and choroidal thickness in pseudoexfoliative glaucoma and pseudoexfoliative syndrome.

    Science.gov (United States)

    Ozge, Gokhan; Koylu, Mehmet Talay; Mumcuoglu, Tarkan; Gundogan, Fatih Cakir; Ozgonul, Cem; Ayyildiz, Onder; Kucukevcilioglu, Murat

    2016-05-01

    To compare retinal nerve fiber layer thickness (RNFLT) and choroidal thickness (ChT) measurements in eyes with pseudoexfoliative (PEX) glaucoma, PEX syndrome and healthy control eyes. Eighteen patients with PEX glaucoma in one eye and PEX syndrome in the fellow eye were included. The right eyes of thirty-nine age- and sex-matched healthy subjects were included as control group. All participants underwent a detailed biomicroscopic and funduscopic examination. RNFLT and ChT measurements were performed with a commercially available spectral-domain optical coherence tomography (SD-OCT). ChT measurements were performed by using enhanced depth imaging (EDI) mode. Patients with PEX underwent diurnal IOP measurements with 4-hour intervals before inclusion in the study. RNFLT results included the average measurement and 6 quadrants (temporal, inferotemporal, inferonasal, nasal, superonasal and supero-temporal). ChT measurements were performed in the subfoveal region and around the fovea (500µm and 1500 µm nasal and temporal to the fovea), as well as around the optic disc (average peripapillary and eight quadrants in the peripapillary region (temporal, inferotemporal, inferior, inferonasal, nasal, superonasal, superior, supero-temporal)). RNFLT in all quadrants and average thickness were significantly lower in PEX glaucoma eyes compared to PEX syndrome eyes and healthy control eyes (p0.05) except the inferotemporal quadrant. ChT measurements were similar between groups (p>0.05). Thinning of the RNFL in association with unchanged ChT may mean that the presence of PEX material is a much more significant risk factor than choroidal changes in the progression of PEX syndrome to PEX glaucoma.

  12. Spin-transfer torque in tunnel junctions with ferromagnetic layer of finite thickness

    International Nuclear Information System (INIS)

    Wilczynski, M.

    2011-01-01

    Two components of the spin torque exerted on a free ferromagnetic layer of finite thickness and a half-infinite ferromagnetic electrode in single tunnel junctions have been calculated in the spin-polarized free-electron-like one-band model. It has been found that the torque oscillates with the thickness of ferromagnetic layer and can be enhanced in the junction with the special layer thickness. The bias dependence of torque components also significantly changes with layer thickness. It is non-symmetric for the normal torque, in contrast to the symmetric junctions with two identical half-infinite ferromagnetic electrodes. The asymmetry of the bias dependence of the normal component of the torque can be also observed in the junctions with different spin splitting of the electron bands in the ferromagnetic electrodes. - Research highlights: → The torque oscillates with the thickness of ferromagnetic layer. → Bias dependence of the torque changes with the layer thickness. → Bias dependence of the normal torque can be asymmetric.

  13. Clad vent set cup open end (closure weld zone) wall-thickness study

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, G.B.; Sherrill, M.W.

    1994-09-01

    The wall thickness at the open end of Clad Vent Set (CVS) cups is a very important parameter for maintaining control of the fueled CVS closure weld process. Ideally, the wall thickness in the closure weld zone should be constant. The DOP-26 iridium alloy is very difficult to machine; therefore, key dimensional features are established during the two-draw warm-forming operation. Unfortunately, anisotropy in the forming blanks produces four ears at the open end of each cup. Formation of these ears produces axial and circumferential variations in wall thickness. The cup certification requirement is that the wall thickness in the closure weld zone, defined as the 2.5-mm band at the open end of a cup, measure from 0.63 to 0.73 mm. The wall thickness certification data for the open end of the CVS cups have been statistically evaluated. These data show that the cups recently produced for the Cassini mission have well-controlled open-end wall thicknesses.

  14. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  15. Evaluation of macular thickness change after inferior oblique muscle recession surgery

    Directory of Open Access Journals (Sweden)

    Ece Turan-Vural

    2014-01-01

    Full Text Available Purpose: This study aimed to evaluate the changes in macular thickness following inferior oblique muscle recession surgery. Materials and Methods: Thirty-eight eyes from 21 patients undergoing ocular muscle surgery were included. Patients were grouped into three groups based on the type of surgical intervention: Group I (n = 12, inferior oblique recession surgery alone; Group II (n = 12, inferior oblique plus horizontal muscle surgery; Group III (n = 14, horizontal muscle surgery alone. Each eye was scanned using the optical coherence tomography (OCT device preoperatively and on the first postoperative day to measure macular thickness. Results: Following surgery, a significant increase in foveal thickness occurred in Group I (P < 0.05 and Group II (P < 0.01. In addition, a statistically significant difference was observed between the groups with regard to the increase in foveal thickness (P = 0.016, with significantly lower changes in Group III. Conclusion: Our findings suggested that inferior oblique muscle recession surgery is associated with an increase in macular thickness.

  16. Occipital bone thickness: Implications on occipital-cervical fusion. A cadaveric study.

    Science.gov (United States)

    Zarghooni, Kourosh; Boese, Chrisoph K; Siewe, Jan; Röllinghoff, Marc; Eysel, Peer; Scheyerer, Max J

    2016-12-01

    The aim of this study was to create a map of the occipital bone using a cadaveric morphometric analysis. Twelve heads, from seven male and five female cadavers, were studied. The thickness of the occipital bone was measured with a digital vernier caliper within a coordinate system. The maximum thickness of the occipital bone could be measured at the external occipital protuberance (mean 15.4 mm; range 9-29.3 mm). All male individuals had higher bone thickness around this point. Further lateral a steady decrease of bone thickness could be observed. Same could be observed in craniocaudal direction. However, values above the superior nuchal line were on average thicker than below. The measurements demonstrated a great individual variability of bone thickness of the occipital bone. The results emphasize the role of preoperative planning for the feasibility of placement of an occipital screw. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  17. Usefulness of left ventricular wall thickness-to-diameter ratio in thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Manno, B.; Hakki, A.H.; Kane, S.A.; Iskandrian, A.S.

    1983-01-01

    The ratio of left ventricular wall thickness to the cavity dimension, as seen on thallium-201 images, was used in this study to predict left ventricular ejection fraction and volume. We obtained rest thallium-201 images in 50 patients with symptomatic coronary artery disease. The thickness of a normal-appearing segment of the left ventricular wall and the transverse diameter of the cavity were measured in the left anterior oblique projection. The left ventricular ejection fraction and volume in these patients were determined by radionuclide ventriculography. There was a good correlation between thickness-to-diameter ratio and ejection fraction and end-systolic volume. In 18 patients with a thickness-to-diameter ratio less than 0.70, the ejection fraction was lower than in the 16 patients with thickness-to-diameter ratio greater than or equal to 1.0. Similarly, in patients with a thickness-to-diameter ratio less than 0.70, the end-diastolic and end-systolic volume were higher than in the remaining patients with higher thickness-to-diameter ratios. All 18 patients with a thickness-to-diameter ratio less than 0.70 had ejection fractions less than 40%; 14 of 15 patients with a thickness-to-diameter ratio greater than or equal to 1.0 had an ejection fraction greater than 40%. The remaining 16 patients with a thickness-to-diameter ratio of 0.7-0.99 had intermediate ejection fractions and volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Ultrasonographic measurement of the axillary recess thickness in an asymptomatic shoulder

    Directory of Open Access Journals (Sweden)

    Gi-Young Park

    2017-04-01

    Full Text Available Purpose The purpose of this study was to measure the axillary recess (AR thickness in an asymptomatic shoulder by using ultrasonography (US and to analyze the factors affecting it. Methods We recruited 141 patients (52 males; 89 females; age, 57.7±9.9 years with unilateral shoulder pain and performed US on the unaffected shoulder. Two physiatrists measured the AR thickness of the unaffected shoulder independently. All patients were examined in an upright sitting position with 90° shoulder abduction. The ultrasonographic transducer was placed longitudinally on the mid-axillary line and along the long axis of the humeral shaft. The factors affecting the AR thickness values were analyzed, and intra-class correlation coefficients were used for assessing the reproducibility of each measurement. Results The intrarater reliability values for the two physiatrists were 0.98 and 0.96, respectively. The inter-rater reliability of the mean AR thickness measurements was 0.91. The mean AR thickness in all subjects, males, and females was 2.8±0.6 mm, 3.1±0.6 mm, and 2.6±0.5 mm (P<0.01, respectively. No difference between the left and the right sides (males, P=0.086; females, P=0.535 or between the dominant and the non-dominant sides (males, P=0.173; female, P=0.244 was found. The AR thickness correlated positively with the height (r=0.313, P<0.01 and the weight (r=0.319, P<0.01. However, it did not correlate with the body mass index (r=0.152, P=0.077 or the age (r=-0.056, P=0.515. Conclusion US measurements of the AR thickness in asymptomatic shoulders demonstrated excellent intrarater and inter-rater reliabilities. The AR thickness showed anatomical variation with sex, height, and weight.

  19. Measurement of Mucosal Thickness in Denture-bearing Area of Edentulous Mandible

    Directory of Open Access Journals (Sweden)

    Jian Dong

    2015-01-01

    Full Text Available Background: The thickness of the alveolar mucosa influences the probability of the occurrence of denture-induced irritations. Thick denture-supporting tissues offer relief from mucosal tenderness and ulcers; however, the uniformity of the thickness across the entire mandibular alveolar mucosa cannot be accurately determined in edentulous patients. This study aimed to assess the mucosal thickness of the denture-bearing area in the edentulous mandible. Methods: Twenty-seven edentulous patients underwent cone-beam computed tomography scanning, wherein the patients wore a record base to retract soft tissues away from the alveolar mucosa. The measured regions were the central incisor (IC, lateral incisor (IL, canine (Ca, first premolar (P1, second premolar (P2, first molar (M1, and second molar (M2 regions. The thickness was measured in the alveolar ridge crest (T, buccal (B1-B4, and lingual (L1-L4 alveolar ridge mucosa. The average thickness of the mucosa at buccal sides (B and lingual sides (L were also assessed. Results: The differences in the mucosal thickness between the left and right sides were not significant. In the Ca-M2 regions, T was the thickest, and L3 was the thinnest of all the measured points in the same regions. L was significantly less than B in posterior regions (P < 0.01. On the other hand, M2 at L4 was thinnest of all the measured regions from Ca to M2 (P < 0.01, and was thicker than IC, IL, P1, and P2 at B2. Conclusions: Since the mucosal thickness of denture-bearing area in the edentulous mandible is not uniform; the tissue surface of the denture base or custom tray should be selectively relieved, which may reduce the risk of denture-induced irritations.

  20. Ultrasonographic measurement of the axillary recess thickness in an asymptomatic shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Park, Gi Young; Lee, Jin Hoon; Kwon, Dae Gil [Dept. of Rehabilitation Medicine, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of)

    2017-04-15

    The purpose of this study was to measure the axillary recess (AR) thickness in an asymptomatic shoulder by using ultrasonography (US) and to analyze the factors affecting it. We recruited 141 patients (52 males; 89 females; age, 57.7±9.9 years) with unilateral shoulder pain and performed US on the unaffected shoulder. Two physiatrists measured the AR thickness of the unaffected shoulder independently. All patients were examined in an upright sitting position with 90° shoulder abduction. The ultrasonographic transducer was placed longitudinally on the mid-axillary line and along the long axis of the humeral shaft. The factors affecting the AR thickness values were analyzed, and intra-class correlation coefficients were used for assessing the reproducibility of each measurement. The intrarater reliability values for the two physiatrists were 0.98 and 0.96, respectively. The inter-rater reliability of the mean AR thickness measurements was 0.91. The mean AR thickness in all subjects, males, and females was 2.8±0.6 mm, 3.1±0.6 mm, and 2.6±0.5 mm (P<0.01), respectively. No difference between the left and the right sides (males, P=0.086; females, P=0.535) or between the dominant and the non-dominant sides (males, P=0.173; female, P=0.244) was found. The AR thickness correlated positively with the height (r=0.313, P<0.01) and the weight (r=0.319, P<0.01). However, it did not correlate with the body mass index (r=0.152, P=0.077) or the age (r=-0.056, P=0.515). US measurements of the AR thickness in asymptomatic shoulders demonstrated excellent intrarater and inter-rater reliabilities. The AR thickness showed anatomical variation with sex, height, and weight.