WorldWideScience

Sample records for skin test panel

  1. Stressed skin panels

    Anon

    2001-07-01

    Advantages and disadvantages of stressed skin panels, also known as structural insulated panels (SIPs), are discussed as material and labour-saving alternatives to traditional stick framing. Stressed skin panels are manufactured 'sandwich' assemblies with a rigid insulating polystyrene foam core, whose interior and exterior surfaces are bonded into panels. The skins distribute and carry the structural loading while the bonded foam core provides insulation and keeps the two skins aligned. Since there are fewer framing members, there is little thermal bridging and the R-value remains high. SIPs are usually manufactured in four feet by eight feet panels, although some manufacturers can produce panels up to eight feet by forty feet. SIPs are resource efficient as they use less wood than conventional framing (about 25 per cent less); can structurally cover large spans, requiring less supplementary framing. Use of SIPs eliminate the need for headers over small openings; provide the ability to nail anywhere; create less scrap and waste; lessen vulnerability to unfavourable weather and other job-site hazards, can reduce delays, and often can produce significant savings in material and labour costs. Limitations include the more complex approaches to plumbing and electrical systems, although this can be minimized by designers by incorporating much of the plumbing and electrical work on interior (non-panel) walls. Most stressed skin panels require one-half inch interior gypsum drywall. If become wet, stressed skin panels take a long time to dry out and may harbour mold growth. Larger stressed-skin panels used in floors and roofs, may require cranes or other machinery for handling because of their weight. Although not without some environmental impact, overall, stressed skin panels are judged to be a resource-efficient building technology with significant energy-efficiency benefits and distinct advantages over stick framing. 3 photos.

  2. Histoplasma skin test

    Histoplasmosis skin test ... health care provider cleans an area of your skin, usually the forearm. An allergen is injected just below the cleaned skin surface. An allergen is a substance that causes ...

  3. Allergy testing - skin

    Patch tests - allergy; Scratch tests - allergy; Skin tests - allergy; RAST test; Allergic rhinitis - allergy testing; Asthma - allergy testing; Eczema - allergy testing; Hayfever - allergy testing; Dermatitis - allergy testing; Allergy testing; ...

  4. Mantoux Tuberculin Skin Test

    Learn how to evaluate people for latent TB infection with the Mantoux tuberculin skin test. This podcast includes sections on administering and reading the Mantoux tuberculin skin test, the standard method for detecting latent TB infection since the 1930s.

  5. Danish translation and validation of the International Skin Tear Advisory Panel Skin Tear Classification System

    Skiveren, J; Bermark, S; LeBlanc, K

    2015-01-01

    OBJECTIVE: The aim of this study was to translate, validate and establish reliability of the International Skin Tear Classification System in Danish. METHOD: Phase 1 of the project involved the translation of the International Skin Tear Advisory Panel (ISTAP) Skin Tear Classification System......) and social and health-care assistants (non-RN) from both primary health care and a Danish university hospital in Copenhagen. Thirty photographs, with equal representation of the three types of skin tears, were selected to test validity. The photographs chosen were those originally used for internal...... and external validation by the ISTAP group. The subjects were approached in their place of work and invited to participate in the study and to attend an educational session related to skin tears. RESULTS: The Danish translation of the ISTAP classification system was tested on 270 non-wound specialists...

  6. Allergy Skin Tests

    ... and symptoms. Medications can interfere with results Before scheduling a skin test, bring your doctor a list ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  7. Tuberculin Skin Testing

    ... Appendix 1 Appendix 2 Appendix 3 Interim Laboratory Biosafety Guidance for XDR Mycobacterium tuberculosis strains Data & Statistics ... The Mantoux tuberculin skin test (TST) is the standard method of determining whether a person is infected ...

  8. Mantoux Tuberculin Skin Test

    2006-11-22

    Learn how to evaluate people for latent TB infection with the Mantoux tuberculin skin test. This podcast includes sections on administering and reading the Mantoux tuberculin skin test, the standard method for detecting latent TB infection since the 1930s.  Created: 11/22/2006 by National Center for HIV, STD and TB Prevention (NCHHSTP).   Date Released: 12/12/2006.

  9. Predicting the Occurrence of Cosmetic Defects in Automotive Skin Panels

    Hazra, S.; Williams, D.; Roy, R.; Aylmore, R.; Allen, M.; Hollingdale, D.

    2011-01-01

    The appearance of defects such as 'hollows' and 'shock lines' can affect the perceived quality and attractiveness of automotive skin panels. These defects are the result of the stamping process and appear as small, localized deviations from the intended styling of the panels. Despite their size, they become visually apparent after the application of paint and the perceived quality of a panel may become unacceptable. Considerable time is then dedicated to minimizing their occurrence through tool modifications. This paper will investigate the use of the wavelet transform as a tool to analyze physically measured panels. The transform has two key aspects. The first is its ability to distinguish small scale local defects from large scale styling curvature. The second is its ability to characterize the shape of a defect in terms of its wavelength and a 'correlation value'. The two features of the transform enable it to be used as a tool for locating and predicting the severity of defects. The paper will describe the transform and illustrate its application on test cases.

  10. Skin graft viability test

    Wahner, H.W.; Robertson, J.S.

    1983-01-01

    With respect to skin pedicles (tubular pedicle or direct flap), an estimation of the blood supply is of great importance in making a decision as to when to perform the separation from the original blood supply. This decision is based on empiric observation of the normal time of healing and varies greatly with the site and the concepts of the individual surgery. A number of methods have been proposed for testing the circulation of pedicle skin flaps or tubes, and these methods all seem more complicated and less accurate than the isotope method that is described in this chapter

  11. Proficiency testing for sensory profile panels : measuring panel performance

    Mcewan, J.A.; Hunter, E.A.; Gemert, L.J. van; Lea, P.

    2002-01-01

    Proficiency testing in sensory analysis is an important step towards demonstrating that results from one sensory panel are consistent with the results of other sensory panels. The uniqueness of sensory analysis poses some specific problems for measuring the proficiency of the human instrument

  12. Optimization of aluminium stressed skin panels in offshore applications

    Hove, van B.W.E.M.; Soetens, F.; Songmene, V.

    2013-01-01

    Since the introduction of Eurocode 9 specific design rules for the calculation of aluminium stressed skin panels are available. These design rules have been used for optimization of two extrusions: one for explosions and wind loading governing and one for explosions and floor loading governing. The

  13. Specifications for Supplementary Classroom Units, Stressed Skin Panel.

    Waring, Robert B.; And Others

    Complete outline specifications are given for the construction of supplementary classroom units using stressed skin panels. Sections included are--(1) concrete and related work, (2) masonry, (3) structural and miscellaneous metal, (4) curtain walls and metal windows, (5) carpentry and related work, (6) roofing, sheet metal, and related work, (7)…

  14. An intersection test for panel unit roots

    Hanck, C.

    2013-01-01

    This article proposes a new panel unit root test based on Simes' ( 1986) classical intersection test. The test is robust to general patterns of cross-sectional dependence and yet is straightforward to implement, only requiring p-values of time series unit root tests of the series in the panel, and

  15. Blood Test: Comprehensive Metabolic Panel (CMP)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Comprehensive Metabolic Panel (CMP) KidsHealth / For Parents / Blood ... de sangre: panel metabólico ampliado What Is a Blood Test? A blood test is when a sample of ...

  16. Gene panel testing for inherited cancer risk.

    Hall, Michael J; Forman, Andrea D; Pilarski, Robert; Wiesner, Georgia; Giri, Veda N

    2014-09-01

    Next-generation sequencing technologies have ushered in the capability to assess multiple genes in parallel for genetic alterations that may contribute to inherited risk for cancers in families. Thus, gene panel testing is now an option in the setting of genetic counseling and testing for cancer risk. This article describes the many gene panel testing options clinically available to assess inherited cancer susceptibility, the potential advantages and challenges associated with various types of panels, clinical scenarios in which gene panels may be particularly useful in cancer risk assessment, and testing and counseling considerations. Given the potential issues for patients and their families, gene panel testing for inherited cancer risk is recommended to be offered in conjunction or consultation with an experienced cancer genetic specialist, such as a certified genetic counselor or geneticist, as an integral part of the testing process. Copyright © 2014 by the National Comprehensive Cancer Network.

  17. Outgassing tests on iras solar panel samples

    Premat, G.; Zwaal, A.; Pennings, N. H.

    1980-01-01

    Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

  18. Orbiter radiator panel solar focusing test

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  19. Robust block bootstrap panel predictability tests

    Westerlund, J.; Smeekes, S.

    2013-01-01

    Most panel data studies of the predictability of returns presume that the cross-sectional units are independent, an assumption that is not realistic. As a response to this, the current paper develops block bootstrap-based panel predictability tests that are valid under very general conditions. Some

  20. Flu Vaccine Skin Patch Tested

    ... Subscribe September 2017 Print this issue Health Capsule Flu Vaccine Skin Patch Tested En español Send us ... Each year, millions of people nationwide catch the flu. The best way to protect yourself is to ...

  1. The skin prick test – European standards

    Heinzerling Lucie

    2013-02-01

    Full Text Available Abstract Skin prick testing is an essential test procedure to confirm sensitization in IgE-mediated allergic disease in subjects with rhinoconjunctivitis, asthma, urticaria, anapylaxis, atopic eczema and food and drug allergy. This manuscript reviews the available evidence including Medline and Embase searches, abstracts of international allergy meetings and position papers from the world allergy literature. The recommended method of prick testing includes the appropriate use of specific allergen extracts, positive and negative controls, interpretation of the tests after 15 – 20 minutes of application, with a positive result defined as a wheal ≥3 mm diameter. A standard prick test panel for Europe for inhalants is proposed and includes hazel (Corylus avellana, alder (Alnus incana, birch (Betula alba, plane (Platanus vulgaris, cypress (Cupressus sempervirens, grass mix (Poa pratensis, Dactilis glomerata, Lolium perenne, Phleum pratense, Festuca pratensis, Helictotrichon pretense, Olive (Olea europaea, mugwort (Artemisia vulgaris, ragweed (Ambrosia artemisiifolia, Alternaria alternata (tenuis, Cladosporium herbarum, Aspergillus fumigatus, Parietaria, cat, dog, Dermatophagoides pteronyssinus, Dermatophagoides farinae, and cockroach (Blatella germanica. Standardization of the skin test procedures and standard panels for different geographic locations are encouraged worldwide to permit better comparisons for diagnostic, clinical and research purposes.

  2. Elevated-Temperature Tests Under Static and Aerodynamic Conditions on Honeycomb-Core Sandwich Panels

    Groen, Joseph M.; Johnson, Aldie E., Jr.

    1959-01-01

    Stainless-steel honeycomb-core sandwich panels which differed primarily in skin thicknesses were tested at elevated temperatures under static and aerodynamic conditions. The results of these tests were evaluated to determine the insulating effectiveness and structural integrity of the panels. The static radiant-heating tests were performed in front of a quartz-tube radiant heater at panel skin temperatures up to 1,5000 F. The aerodynamic tests were made in a Mach 1.4 heated blowdown wind tunnel. The tunnel temperature was augmented by additional heat supplied by a radiant heater which raised the panel surface temperature above 8000 F during air flow. Static radiant-heating tests of 2 minutes duration showed that all the panels protected the load-carrying structure about equally well. Thin-skin panels showed an advantage for this short-time test over thick-skin panels from a standpoint of weight against insulation. Permanent inelastic strains in the form of local buckles over each cell of the honeycomb core caused an increase in surface roughness. During the aero- dynamic tests all of the panels survived with little or no damage, and panel flutter did not occur.

  3. Quiz: Test Your Skin Cancer IQ

    ... Feature: Skin Cancer Quiz: Test Your Skin Cancer IQ Past Issues / Summer 2013 Table of Contents 1. ... Sun – Safety First / Quiz: Test Your Skin Cancer IQ Summer 2013 Issue: Volume 8 Number 2 Page ...

  4. Lepromin skin test

    ... if left untreated. It is caused by Mycobacterium leprae bacteria. This test is a research tool that ... Renault CA, Ernst JD. Mycobacterium leprae (leprosy). In: Bennett ... Principles and Practice of Infectious Diseases, Updated Edition . ...

  5. Weight reductions for the airbus A380; postbuckling of the A380 VTP skin panels

    Kroese, R.

    2014-01-01

    The skin panels of the Vertical Tail Plane (VTP) are the largest single piece composite components assembled on the Airbus A380. By allowing postbuckling to these skin panels might result in severe weight reductions for the VTP of the A380. The goal of the study is to give an indication of possible

  6. Developing a solar panel testing system

    Árpád Rácz

    2009-10-01

    Full Text Available Solar energy is increasingly used togenerate electricity for individual households. There isa wide variety of solar panel technologies, whichshould be tested at an individual level during theirlifetime. In this paper, the development of a testingstation at the University of Debrecen is presented. Thetesting system can be used for research andeducational purposes and for in field applicationsequally well.

  7. Improvements in skin-testing technique.

    Carr, Warner W

    2006-01-01

    Allergy skin testing is the primary modality used in the diagnosis of allergic diseases and guides development of treatment and avoidance plans. The goal of the Allergist is to skin test the appropriate population with a device and technique that minimizes pain while maximizing sensitivity and specificity. The debate involving the use of intradermal versus skin-prick testing in the diagnosis of aeroallergy has been long lasting. Past and present medical literature will be reviewed, establishing the lack of diagnostic use of intradermal testing in the setting of aeroallergy. New skin devices continue to be developed with a trend toward production of multidevices. Performance characteristics of various skin test devices will be reviewed with an emphasis on sensitivity, specificity, and variability of skin-prick testing devices. Significant statistical differences exist between all devices tested and reported in the literature. Whether these statistical differences equate to clinical differences is not known. With this review the practicing allergist should carefully evaluate multiple different devices and choose a device that suits their practice needs. In addition, allergists must ensure that technicians are sufficiently trained on the correct use of their device and should conduct continuing education to ensure that proper skin testing techniques are being used in their practice. Finally, the use of skin testing in pediatrics will be reviewed with a focus on safety. Care should be taken when skin testing infants < or = 6 months of age, especially in the setting of eczema and a family history of atopy.

  8. Tuned Chamber Core Panel Acoustic Test Results

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  9. Nonlinear Analysis and Post-Test Correlation for a Curved PRSEUS Panel

    Gould, Kevin; Lovejoy, Andrew E.; Jegley, Dawn; Neal, Albert L.; Linton, Kim, A.; Bergan, Andrew C.; Bakuckas, John G., Jr.

    2013-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept, developed by The Boeing Company, has been extensively studied as part of the National Aeronautics and Space Administration's (NASA s) Environmentally Responsible Aviation (ERA) Program. The PRSEUS concept provides a light-weight alternative to aluminum or traditional composite design concepts and is applicable to traditional-shaped fuselage barrels and wings, as well as advanced configurations such as a hybrid wing body or truss braced wings. Therefore, NASA, the Federal Aviation Administration (FAA) and The Boeing Company partnered in an effort to assess the performance and damage arrestments capabilities of a PRSEUS concept panel using a full-scale curved panel in the FAA Full-Scale Aircraft Structural Test Evaluation and Research (FASTER) facility. Testing was conducted in the FASTER facility by subjecting the panel to axial tension loads applied to the ends of the panel, internal pressure, and combined axial tension and internal pressure loadings. Additionally, reactive hoop loads were applied to the skin and frames of the panel along its edges. The panel successfully supported the required design loads in the pristine condition and with a severed stiffener. The panel also demonstrated that the PRSEUS concept could arrest the progression of damage including crack arrestment and crack turning. This paper presents the nonlinear post-test analysis and correlation with test results for the curved PRSEUS panel. It is shown that nonlinear analysis can accurately calculate the behavior of a PRSEUS panel under tension, pressure and combined loading conditions.

  10. Supersonic Panel Flutter Test Results for Flat Fiber-Glass Sandwich Panels with Foamed Cores

    Tuovila, W. J.; Presnell, John G., Jr.

    1961-01-01

    Flutter tests have been made on flat panels having a 1/4 inch-thick plastic-foam core covered with thin fiber-glass laminates. The testing was done in the Langley Unitary Plan wind tunnel at Mach numbers from 1.76 t o 2.87. The flutter boundary for these panels was found to be near the flutter boundary of thin metal panels when compared on the basis of an equivalent panel stiffness. The results also demonstrated that the depth of the cavity behind the panel has a pronounced influence on flutter. Changing the cavity depth from 1 1/2 inches to 1/2 inch reduced the dynamic pressure at start of flutter by 40 percent. No flutter was obtained when the spacers on the back of the panel were against the bottom of the cavity.

  11. Multiple Site Damage in Flat Panel Testing

    Shrage, Daniel

    2000-01-01

    This report aimed to experimentally verify analytical models that predict the residual strength of representative aircraft structures, such as wide panels, that are subjected to Multiple Site Damage (MSD...

  12. Skin prick test in patients with chronic allergic skin disorders

    Pooja Bains

    2015-01-01

    Full Text Available Background: Chronic allergic skin disorders are the inflammatory and proliferative conditions in which both genetic and environmental factors play important roles. Chronic idiopathic urticaria (CIU and atopic dermatitis (AD are among the most common chronic allergic skin disorders. These can be provoked by various food and aeroallergens. Skin prick tests (SPTs represent the cheapest and most effective method to diagnose type I hypersensitivity. Positive skin tests with a history suggestive of clinical sensitivity strongly incriminate the allergen as a contributor to the disease process. Aim s and Objectives: To determine the incidence of positive SPT in patients with chronic allergic skin disorders and to identify the various allergens implicated in positive SPT. Methods: Fifty patients of chronic allergic disorders were recruited in this study. They were evaluated by SPT with both food and aeroallergens. Results: In our study, SPT positivity in patients of CIU was 63.41% and in AD was 77.78%. Out of the 41 patients of CIU, the most common allergen groups showing SPT positivity were dust and pollen, each comprising 26.83% patients. SPT reaction was positive with food items (21.6%, insects (17.07%, fungus (12.20%, and Dermatophagoides farinae, that is, house dust mite (HDM (7.32%. The allergen which showed maximum positivity was grain dust wheat (19.51%. Among nine patients of AD, maximum SPT positivity was seen with Dermatophagoides farinae, pollen Amaranthus spinosus, grain dust wheat, and cotton mill dust; each comprising 22.22% of patients. Conclusion: Our study showed that a significant number of patients of CIU and AD showed sensitivity to dust, pollen, insects, Dermatophagoides farinae, and fungi on SPT. Thus, it is an important tool in the diagnosis of CIU and AD.

  13. Creep-age forming of AA7475 aluminum panels for aircraft lower wing skin application

    Diego José Inforzato

    2012-08-01

    Full Text Available Creep-age forming (CAF is an interesting process for the airframe industry, as it is able to form or shape panels into smooth, but complex, curvatures. In the CAF process, the ageing cycle of the alloy is used to relax external loads imposed to the part, through creep mechanisms. Those relaxed stresses impose a new curvature to the part. At the end of the process, significant spring back (sometimes about 70% is observed and the success in achieving the desired form depends on how the spring back can be predicted in order to compensate it by tooling changes. Most of the applications relate to simple (non stiffened panels. The present work deals with the CAF of aluminum panels for aircraft wing skin application. CAF was performed using vacuum-bagging autoclave technique in small scale complex shape stiffened panels, machined from an AA7475 alloy plate. An analytical reference model from the literature was employed estimate the spring back effect in such panel geometry. This model that deals with simple plates was adapted to stiffened panels using a geometric simplification, resulting in a semi-empirical model. The results demonstrate that CAF is a promising process to form stiffened panels, and the spring back can be roughly estimated through a simple model and few experiments.

  14. Discussion panel: field test design & data analysis

    Daniel M. Schmitt; William E. Waters; B. Leo Cadogan; Gerald S. Walton

    1985-01-01

    I think it is time to open the panel. On my left respectively are Bill Waters, Professor of Entomology and Forestry, University of California, Berkeley; Gerald S. Walton, Biometrician, Northeastern Forest Experiment Station, Hamden; and Leo Cadogan, Forest Pest Management Institute, Canadian Forestry Service, Sault Ste. Marie, Ontario. My name is Dan Schmitt, Program...

  15. Outer skin protection of columbium Thermal Protection System (TPS) panels

    Culp, J. D.

    1973-01-01

    A coated columbium alloy material system 0.04 centimeter thick was developed which provides for increased reliability to the load bearing character of the system in the event of physical damage to and loss of the exterior protective coating. The increased reliability to the load bearing columbium alloy (FS-85) was achieved by interposing an oxidation resistant columbium alloy (B-1) between the FS-85 alloy and a fused slurry silicide coating. The B-1 alloy was applied as a cladding to the FS-85 and the composite was fused slurry silicide coated. Results of material evaluation testing included cyclic oxidation testing of specimens with intentional coating defects, tensile testing of several material combinations exposed to reentry profile conditions, and emittance testing after cycling of up to 100 simulated reentries. The clad material, which was shown to provide greater reliability than unclad materials, holds significant promise for use in the thermal protection system of hypersonic reentry vehicles.

  16. Thermal stress analysis of space shuttle orbiter wing skin panel and thermal protection system

    Ko, William L.; Jenkins, Jerald M.

    1987-01-01

    Preflight thermal stress analysis of the space shuttle orbiter wing skin panel and the thermal protection system (TPS) was performed. The heated skin panel analyzed was rectangular in shape and contained a small square cool region at its center. The wing skin immediately outside the cool region was found to be close to the state of elastic instability in the chordwise direction based on the conservative temperature distribution. The wing skin was found to be quite stable in the spanwise direction. The potential wing skin thermal instability was not severe enough to tear apart the strain isolation pad (SIP) layer. Also, the preflight thermal stress analysis was performed on the TPS tile under the most severe temperature gradient during the simulated reentry heating. The tensile thermal stress induced in the TPS tile was found to be much lower than the tensile strength of the TPS material. The thermal bending of the TPS tile was not severe enough to cause tearing of the SIP layer.

  17. Stress Testing of Organic Light- Emitting Diode Panels and Luminaires

    Lynn Davis, Kelley Rountree, Karmann Mills

    2018-01-31

    This report builds on previous DOE efforts with OLED technology by updating information on a previously benchmarked OLED product (the Chalina luminaire from Acuity Brands) and provides new benchmarks on the performance of Brite 2 and Brite Amber OLED panels from OLEDWorks. During the tests described here, samples of these devices were subjected to continuous operation in stress tests at elevated ambient temperature environments of 35°C or 45°C. In addition, samples were also operated continuously at room temperature in a room temperature operational life test (RTOL). One goal of this study was to investigate whether these test conditions can accelerate failure of OLED panels, either through panel shorting or an open circuit in the panel. These stress tests are shown to provide meaningful acceleration of OLED failure modes, and an acceleration factor of 2.6 was calculated at 45°C for some test conditions. In addition, changes in the photometric properties of the emitted light (e.g., luminous flux and chromaticity maintenance) was also evaluated for insights into the long-term stability of these products compared to earlier generations. Because OLEDs are a lighting system, electrical testing was also performed on the panel-driver pairs to provide insights into the impact of the driver on long-term panel performance.

  18. Static and fatigue experimental tests on a full scale fuselage panel and FEM analyses

    Raffaele Sepe

    2016-02-01

    Full Text Available A fatigue test on a full scale panel with complex loading condition and geometry configuration has been carried out using a triaxial test machine. The demonstrator is made up of two skins which are linked by a transversal butt-joint, parallel to the stringer direction. A fatigue load was applied in the direction normal to the longitudinal joint, while a constant load was applied in the longitudinal joint direction. The test panel was instrumented with strain gages and previously quasi-static tests were conducted to ensure a proper load transferring to the panel. In order to support the tests, geometric nonlinear shell finite element analyses were conducted to predict strain and stress distributions. The demonstrator broke up after about 177000 cycles. Subsequently, a finite element analysis (FEA was carried out in order to correlate failure events; due to the biaxial nature of the fatigue loads, Sines criterion was used. The analysis was performed taking into account the different materials by which the panel is composed. The numerical results show a good correlation with experimental data, successfully predicting failure locations on the panel.

  19. Natural history of skin prick test reactivity

    Schou Nielsen, Jesper; Meteran, Howraman; Ulrik, Charlotte Suppli

    2017-01-01

    population sample of children and adolescents in relation to symptoms of rhinitis. METHODS: A total of 983 individuals, aged 7 to 17 years, were randomly selected in 1986 and invited to 4 examinations during a 20-year period. During each examination, a skin prick test was performed using common local...

  20. Numerical simulation study on rolling-chemical milling process of aluminum-lithium alloy skin panel

    Huang, Z. B.; Sun, Z. G.; Sun, X. F.; Li, X. Q.

    2017-09-01

    Single curvature parts such as aircraft fuselage skin panels are usually manufactured by rolling-chemical milling process, which is usually faced with the problem of geometric accuracy caused by springback. In most cases, the methods of manual adjustment and multiple roll bending are used to control or eliminate the springback. However, these methods can cause the increase of product cost and cycle, and lead to material performance degradation. Therefore, it is of significance to precisely control the springback of rolling-chemical milling process. In this paper, using the method of experiment and numerical simulation on rolling-chemical milling process, the simulation model for rolling-chemical milling process of 2060-T8 aluminum-lithium alloy skin was established and testified by the comparison between numerical simulation and experiment results for the validity. Then, based on the numerical simulation model, the relative technological parameters which influence on the curvature of the skin panel were analyzed. Finally, the prediction of springback and the compensation can be realized by controlling the process parameters.

  1. Evaluation of sex-related changes in skin topography and structure using innovative skin testing equipment.

    Dąbrowska, M; Mielcarek, A; Nowak, I

    2018-04-29

    Evaluation of skin condition on the basis of parametrization and objective measurements of the parameters has become obligatory. The aim of this study was to assess sex-related changes in skin topography and structure using the skin testing equipment. The study was carried out on the group of 40 volunteers (20 females and 20 males) of the mean age 24 ± 3 years. The skin parameters were measured using 3 devices: Visioscan ®  VC 98 (skin topography), Visioline ® VL 650 (skin macro relief) and Ultrascan UC22 (ultrasound imaging of the skin). All measurements were performed on the inner part of the left forearm. The skin parameters measured revealed significant differences in skin surface and structure between females and males. The skin of all women subjects was more homogenous in its structure with the presence of more abundant superficial skin lines and wrinkles in comparison to male skin. The higher number of skin furrows in the skin of women is in agreement with literature reports claiming that men's skin has lower number of wrinkles which are deeper and more pronounced. Ultrasound imaging of the skin indicated greater thickness and lower density of the dermis of men subjects compared to those of females. Non-invasive methods of skin testing using new and advanced equipment have provided a possibility of objective parametrization and evaluation of sex-related changes in skin topography and structure. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. In-plane shear test of fibre reinforced concrete panels

    Solgaard, Anders Ole Stubbe; Stang, Henrik; Goltermann, Per

    2008-01-01

    The present paper concerns the investigation of polymer Fiber Reinforced Concrete (FRC) panels subjected to in-plane shear. The use of fibers as primary reinforcement in panels is a new application of fiber reinforcement, hence test methods, design bases and models are lacking. This paper...... contributes to the investigation of fibers as reinforcement in panels with experimental results and a consistent approach to material characterization and modeling. The proposed model draws on elements from the classical yield line theory of rigid, perfectly plastic materials and the theory of fracture...... mechanics. Model panels have been cast to investigate the correlation between the load bearing capacity and the amount of fibers (vol. %) in the mixture. The type of fibers in the mixture was Poly Vinyl Alcohol (PVA) fibers, length 8 mm, diameter 0.04 mm. The mechanical properties of the FRC have been...

  3. Blood Test: Basic Metabolic Panel (BMP)

    ... this topic for: Parents Kids Teens Definition: Hypoglycemia Diabetes Center Hypoglycemia Calcium Urine Test: Microalbumin-to-Creatinine Ratio When Your Child Has a Chronic Kidney Disease Kidneys and Urinary ...

  4. A Bootstrap Cointegration Rank Test for Panels of VAR Models

    Callot, Laurent

    functions of the individual Cointegrated VARs (CVAR) models. A bootstrap based procedure is used to compute empirical distributions of the trace test statistics for these individual models. From these empirical distributions two panel trace test statistics are constructed. The satisfying small sample...

  5. Syndromic Panel-Based Testing in Clinical Microbiology.

    Ramanan, Poornima; Bryson, Alexandra L; Binnicker, Matthew J; Pritt, Bobbi S; Patel, Robin

    2018-01-01

    The recent development of commercial panel-based molecular diagnostics for the rapid detection of pathogens in positive blood culture bottles, respiratory specimens, stool, and cerebrospinal fluid has resulted in a paradigm shift in clinical microbiology and clinical practice. This review focuses on U.S. Food and Drug Administration (FDA)-approved/cleared multiplex molecular panels with more than five targets designed to assist in the diagnosis of bloodstream, respiratory tract, gastrointestinal, or central nervous system infections. While these panel-based assays have the clear advantages of a rapid turnaround time and the detection of a large number of microorganisms and promise to improve health care, they present certain challenges, including cost and the definition of ideal test utilization strategies (i.e., optimal ordering) and test interpretation. Copyright © 2017 American Society for Microbiology.

  6. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  7. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  8. A simple nonstationary-volatility robust panel unit root test

    Demetrescu, Matei; Hanck, Christoph

    2012-01-01

    We propose an IV panel unit root test robust to nonstationary error volatility. Its finite-sample performance is convincing even for many units and strong cross-correlation. An application to GDP prices illustrates the inferential impact of nonstationary volatility. (C) 2012 Elsevier B.V. All rights

  9. Progress and Strategies for Testing of Materials for Solar Panels

    Kurtz, Sarah

    2017-04-25

    Accelerated testing is key to confident launch of a new product. However, for new products like solar panels, the best approach is not always clear. The challenge for materials manufacturers is that test times can be long. Also, small-coupon testing may not predict the behavior in the full-size module, but testing of the full-size module is too expensive. As a result, solar panel test standards like IEC 61215 are useful, but are not sufficient. Material manufacturers have needed to define their own test protocols. This presentation will review some historical data (e.g., data show that manufacturers are making great progress toward reducing encapsulant discoloration) and describe advances in material testing (for example, new techniques are being demonstrated on how to more quantitatively assess adhesion, detect tendency for delamination, and understand how encapsulant properties affect other properties like cracking of cells). The International PV Quality Assurance Task Force has been researching climate-specific weathering tests toward the goal of defining international standards that would simplify qualification and quality assurance testing for materials. The status of these tests and the strategies for how to organize these standards to best meet the needs of the industry will be discussed.

  10. Tank testing of a 2500-cm2 solar panel

    Bever, R. S.; Staskus, J.

    1981-01-01

    A 50 cm by 50 cm solar array panel test patch was investigated for spacecraft charging and arcing effects. Bombardment with monochromatic electron was carried out. Some objectives of the test were: (1) to estimate at what voltage of electron bombardment arcing would be probable; (2) to find whether the arc's energy would be tolerable or damagingly large; (3) to try and separate thermal and photoeffects; and, (4) to see whether materials used were such as to minimize arcing. Some conclusions were: In sunlight the tracking data relay satellite's solar panel which has ceria glass on the front and conductive paint on the backside is probably a good design for reducing charge-up. In a geomagnetic substorm simulated in testing there will be arcing at the interconnects during eclipse and transitions into and out of eclipse in testing especially in view of the very cold temperatures that will be reached by this lightweight array. Ceria-doped glass is preferred to fused silica glass for reducing charge build up. The Kapton bare patch should still be conductively painted. The differential voltages on the panel determine when arcing first begins, and the electron beam voltages vary depending upon whether the metallic structure is directly grounded or semifloating.

  11. Simulated hail impact testing of photovoltaic solar panels

    Moore, D.; Wilson, A.; Ross, R.

    1978-01-01

    Techniques used to simulate and study the effect of hail on photovoltaic solar panels are described. Simulated hail stones (frozen ice spheres projected at terminal velocity) or steel balls were applied by air guns, gravity drop, or static loading. Tests with simulated hail and steel balls yielded different results. The impact strength of 10 commercially available flat-plate photovoltaic modules was tested. It was found that none of the six panel designs incorporating clear potting silicone material as the outermost layer remained undamaged by 1-in. simulated hailstones, while a photovoltaic module equipped with a 0.188-in.-thick acrylic cover sheet would be able to withstand the impact of a 2-in.-diameter hailstone.

  12. A parametric study on supersonic/hypersonic flutter behavior of aero-thermo-elastic geometrically imperfect curved skin panel

    Abbas, L.K.; Rui, X.; Marzocca, P.; Abdalla, M.; De Breuker, R.

    2011-01-01

    In this paper, the effect of the system parameters on the flutter of a curved skin panel forced by a supersonic/hypersonic unsteady flow is numerically investigated. The aeroelastic model investigated includes the third-order piston theory aerodynamics for modeling the flow-induced forces and the

  13. [Allergens used in skin tests in Mexico].

    Larenas Linnemann, Désirée; Arias Cruz, Alfredo; Guidos Fogelbach, Guillermo Arturo; Cid del Prado, Mari Lou

    2009-01-01

    Immunotherapy is the only recognized causal treatment for allergies. It is prepared on an individual basis, based on the patient's clinical history and the result of the skin prick test (SPT). An adequate composition of the allergens with which to test the patient is crucial for an optimal diagnosis. To know allergens used in tests in allergy practices in Mexico. A national survey among all members of the Colegio Mexicano de Inmunología Clínica y Alergia (CMICA) and of the Colegio Mexicano de Pediatras Especialistas en Inmunología Clínica y Alergia (COMPEDIA) was carried out. In a second phase respondents were asked to send in the composition of a routine SPT in their clinic. The results are presented descriptively and the frequency is calculated by which certain allergen is tested in the interviewed practices. A survey response rate of 61 (17%) was obtained and 54% showed their SPT content. Weeds' representation in the SPT seems adequate; Atriplex is tested in all allergy practices. Some trees that show cross-reactivity might be eliminated from the SPT, but 20% doesn't test for Cynodon nor Holcus, and 25% doesn't for important allergens as cat, dog and cockroach. House dust and tobacco are still tested with certain frequency. The selection of which allergens to test in a SPT is based on multiple data, that change continuously with new investigations and discoveries. Our specialty is the most indicated--and obligated--to adjust constantly to these changes to have the best diagnostic tool to detect specific allergies.

  14. Tuberculin skin testing: Spectrum of adverse reactions.

    Praveen, Ramar; Bahuguna, Amit; Dhadwal, Bhumesh Singh

    2015-01-01

    Tuberculin skin testing (TST) is one of the primary diagnostic modalities recommended by the World Health Organization (WHO) and the National Institute for Health and Care Excellence (NICE) study conducted in the United Kingdom (UK) for diagnosing tuberculosis (TB). Even after acceptance as a diagnostic modality and stern standardization, TST has its own flaws that include a spectrum of adverse reactions. We report a series of cases with a spectrum of adverse reactions occurring with a higher frequency than present in the available evidence. The study has some demerits such as being a retrospective one with interobserver variation and lack of histopathological confirmation. The observation is presented to accentuate the fact that adverse reactions are not a rarity and that further studies are required to establish the cause and exact incidence of the same.

  15. Ageing tests study on wood-based sandwich panels

    Mateo, Raquel

    2011-12-01

    Full Text Available Composite lightweight wood panels are being increasingly used in construction in Spain. Their growing use should be accompanied by necessary guarantees based on studies of their properties. As it is prescriptive and in addition to others tests, in the present work is examinated the durability of these panels when exposed to the climatic conditions, a characteristic of great importance for wood products, according to Guide ETAG 016, the current standard defining the ageing tests to be used. However, due to the use class of this material, there are indications that the testing outlined in this Guide is inappropriate for assessing the ageing of wood-based sandwich panels. Alternative tests are here proposed that recreate rather better the real conditions under which these products are used. Covering the samples in a waterproof sheeting permeable to the outward movement of water vapour, which is in fact used in the installation, provided the best procedure for testing these panels.

    Los paneles sándwich de madera son un producto de creciente aplicación en la edificación de nuestro país. Este ascendente uso del material debe estar acompañado de las garantías necesarias avaladas por un estudio previo de sus prestaciones. Como es preceptivo y entre otros, se evalúa su durabilidad frente a las condiciones climatológicas, clave en los productos derivados de la madera, acorde a la normativa actual definida con tal fin, la Guía ETAG 016. Sin embargo, debido a la clase de uso del material, se ha detectado que dicha normativa tal y como está concebida no es capaz de valorar su envejecimiento adecuadamente. En este trabajo se proponen ensayos alternativos al establecido tras exhaustivos análisis que recrean las condiciones reales de uso y más acordes a los productos de madera. Se concluye que la incorporación de una lámina impermeable pero permeable al vapor de agua hacia el exterior, como las utilizadas en el montaje, aportan el mejor

  16. Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

    Frady, Gregory P.; Duvall, Lowery D.; Fulcher, Clay W. G.; Laverde, Bruce T.; Hunt, Ronald A.

    2011-01-01

    rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for component-loaded curved orthogrid panels typical of launch vehicle skin structures. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was applied to correlate the measured input sound pressures across the energized panel. This application quantifies the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software developed for the RPTF method allows easy replacement of the diffuse acoustic field with other pressure fields such as a turbulent boundary layer (TBL) model suitable for vehicle ascent. Structural responses

  17. A test battery measuring auditory capabilities of listening panels

    Ghani, Jody; Ellermeier, Wolfgang; Zimmer, Karin

    2005-01-01

    a battery of tests covering a larger range of auditory capabilities in order to assess individual listeners. The format of all tests is kept as 'objective' as possible by using a three-alternative forced-choice paradigm in which the subject must choose which of the sound samples is different, thus keeping...... the instruction to the subjects simple and common for all tests. Both basic (e.g. frequency discrimination) and complex (e.g. profile analysis) psychoacoustic tests are covered in the battery and a threshold of discrimination or detection is obtained for each test. Data were collected on 24 listeners who had been...... recruited for participation in an expert listening panel for evaluating the sound quality of hi-fi audio systems. The test battery data were related to the actual performance of the listeners when judging the degradation in quality produced by audio codecs....

  18. Mechanical testing of a FW panel attachment system for ITER

    Oliva, Vladislav; Vaclavik, Jaroslav; Materna, Ales; Lorenzetto, Patrick; Furmanek, Andreas

    2009-01-01

    An objective of experiments and finite element simulations was to check the stiffness, the strength and the fatigue resistance of the attachment of the First Wall panels onto a shield block of blanket modules according to the ITER 2001 design. The panel has a poloidal key at the rear side (in so-called option A with the rear access bolting) and it is attached by means of special studs located on a key-way in the shield block. Special device for a test of stud tensile pre-load relaxation during a thermal cycling was developed. True-to-scale panels, the shield block mock-up and simplified studs were fabricated and the assembly was loaded alternatively by radial moment, poloidal force or poloidal moment simulating the loading during off-normal plasma operations. Thermal cycling led to an acceptable stud pre-load relaxation. Mechanical cycling caused neither the pre-load relaxation nor the loss of the contact in the key-way nor a damage of the attachment system. The combination of poloidal moment and radial force during vertical displacement events (VDEs) seems to be a most dangerous case because it could lead to the loss of the key-key-way contact.

  19. Alternative methods for skin irritation testing: the current status : ECVAM skin irritation task force report 1

    Botham, P.A.; Earl, L.K.; Fentem, J.H.; Roguet, R.; Sandt, J.J.M.

    1998-01-01

    The ECVAM Skin Irritation Task Force was established in November 1996, primarily to prepare a report on the current status of the development and validation of alternative tests for skin irritation and corrosion and, in particular, to identify any appropriate non-animal tests for predicting human

  20. Analysis and Tests of Reinforced Carbon-Epoxy/Foam-Core Sandwich Panels with Cutouts

    Baker, Donald J.; Rogers, Charles

    1996-01-01

    The results of a study of a low-cost structurally efficient minimum-gage shear-panel design that can be used in light helicopters are presented. The shear-panel design is based on an integrally stiffened syntactic-foam stabilized-skin with an all-bias-ply tape construction for stabilized-skin concept with an all-bias-ply tape construction for the skins. This sandwich concept is an economical way to increase the panel bending stiffness weight penalty. The panels considered in the study were designed to be buckling resistant up to 100 lbs/in. of shear load and to have an ultimate strength of 300 lbs/in. The panel concept uses unidirectional carbon-epoxy tape on a syntactic adhesive as a stiffener that is co-cured with the skin and is an effective concept for improving panel buckling strength. The panel concept also uses pultruded carbon-epoxy rods embedded in a syntactic adhesive and over-wrapped with a bias-ply carbon-epoxy tape to form a reinforcing beam which is an effective method for redistributing load around rectangular cutout. The buckling strength of the reinforced panels is 83 to 90 percent of the predicted buckling strength based on a linear buckling analysis. The maximum experimental deflection exceeds the maximum deflection predicted by a nonlinear analysis by approximately one panel thickness. The failure strength of the reinforced panels was two and a half to seven times of the buckling strength. This efficient shear-panel design concept exceeds the required ultimate strength requirement of 300 lbs/in by more than 100 percent.

  1. 10-MWe pilot-plant-receiver panel test requirements document solar thermal test facility

    1978-08-25

    Testing plans for a full-scale test receiver panel and supporting hardware which essentially duplicate both physically and functionally, the design planned for the Barstow Solar Pilot Plant are presented. Testing is to include operation during normal start and shutdown, intermittent cloud conditions, and emergencies to determine the panel's transient and steady state operating characteristics and performance under conditions equal to or exceeding those expected in the pilot plant. The effects of variations of input and output conditions on receiver operation are also to be investigated. Test hardware are described, including the pilot plant receiver, the test receiver assembly, receiver panel, flow control, electrical control and instrumentation, and structural assembly. Requirements for the Solar Thermal Test Facility for the tests are given. The safety of the system is briefly discussed, and procedures are described for assembly, installation, checkout, normal and abnormal operations, maintenance, removal and disposition. Also briefly discussed are quality assurance, contract responsibilities, and test documentation. (LEW)

  2. Fabrication and testing of fire resistant graphite composite panels

    Roper, W. D.

    1986-01-01

    Eight different graphite composite panels were fabricated using four different resin matrices. The resin matrices included Hercules 71775, a blend of vinylpolystyrpyridine and bismaleimide, H795, a bismaleimide, Cycom 6162, a phenolic, and PSP 6022m, a polystyrylpyridine. Graphite panels were fabricated using fabric or unidirectional tape. Described are the processes for preparing these panels and some of their mechanical, thermal and flammability properties. Panel properties are compared with state-of-the-art epoxy fiberglass composite panels.

  3. The development of an Infrared Environmental System for TOPEX Solar Panel Testing

    Noller, E.

    1994-01-01

    Environmental testing and flight qualification of the TOPEX/POSEIDON spacecraft solar panels were performed with infrared (IR) lamps and a control system that were newly designed and integrated. The basic goal was more rigorous testing of the costly panels' new composite-structure design without jeopardizing their safety. The technique greatly reduces the costs and high risks of testing flight solar panels.

  4. Panel manipulation in social stress testing: The Bath Experimental Stress Test for Children (BEST-C).

    Cheetham, Tara J; Turner-Cobb, Julie M

    2016-01-01

    Whilst acute stress paradigms in adults make use of adult panel members, similar paradigms modified for child participants have not manipulated the panel. Most work has utilised an audience of adult confederates, regardless of the age of the population being tested. The aim of this study was to trial a social stress test for children that provided a meaningful environment using age-matched child peers as panel actors. Thirty-three participants (7-11 years) underwent the Bath Experimental Stress Test for Children (BEST-C). Based on the Trier Social Stress Test (TSST), it comprises a shortened six-minute public speaking task and four-minute maths challenge. It differs from previous stress tests by using age-matched children on the panel, pre-recorded and presented as a live feed, and includes an expanded manipulation check of subjective experience. Salivary cortisol was assessed at four time points, pre-post stress testing; life events, daily hassles and coping strategies were measured through questionnaires. A simple numerical coding scheme was applied to post-test interview data. The BEST-C generated a typical stress and adaptation response in salivary cortisol (p=.032). Age and gender differences were observed during recovery. Cortisol responses mapped directly onto three distinct subjective response patterns: (i) expected response and recovery; (ii) expected response, no recovery; (iii) no response. The BEST-C, utilising child confederates of participant target age is a meaningful social stress test for children. This is the first social stress test developed specifically for children that manipulates panel characteristics by using child confederates and a pre-recorded sham panel. Greater cortisol responses to the test were also found to match subjective verbal accounts of the experience. It offers a meaningful acute stress paradigm with potential applications to other child and adolescent age groups. Furthermore, it leads the way in the use of panel manipulation

  5. Analysis and design of lattice materials for large cord and curvature variations in skin panels of morphing wings

    Vigliotti, Andrea; Pasini, Damiano

    2015-01-01

    In the past few decades, several concepts for morphing wings have been proposed with the aim of improving the structural and aerodynamic performance of conventional aircraft wings. One of the most interesting challenges in the design of a morphing wing is represented by the skin, which needs to meet specific deformation requirements. In particular when morphing involves changes of cord or curvature, the skin is required to undergo large recoverable deformation in the actuation direction, while maintaining the desired shape and strength in the others. One promising material concept that can meet these specifications is represented by lattice materials. This paper examines the use of alternative planar lattices in the embodiment of a skin panel for cord and camber morphing of an aircraft wing. We use a structural homogenization scheme capable of capturing large geometric nonlinearity, to examine the structural performance of lattice skin concepts, as well as to tune their mechanical properties in desired directions. (technical note)

  6. Hepatitis Panel: MedlinePlus Lab Test Information

    ... this page: https://medlineplus.gov/labtests/hepatitispanel.html Hepatitis Panel To use the sharing features on this page, please enable JavaScript. What is a Hepatitis Panel? Hepatitis is a type of liver disease. ...

  7. Differential skin test reactivity to pollens in pollen food allergy syndrome versus allergic rhinitis.

    Ta, Von; Scott, David R; Chin, William K; Wineinger, Nathan E; Kelso, John M; White, Andrew A

    2015-01-01

    Pollen food allergy syndrome (PFAS), also called oral allergy syndrome, is a form of food allergy in which uncooked foods cause allergic symptoms generally limited to the oral mucosa. It occurs in a subset of patients with pollen allergy, although not all patients have prominent rhinitis symptoms. PFAS is related to antigenic similarity between the pollen and food allergen. The size of skin test reactions in a group of subjects with pollen sensitivity with PFAS was compared with a group of subjects who were pollen sensitive and without PFAS. Self-reported rhinitis symptoms between the two groups were compared to identify if symptom severity differed. Twenty subjects with PFAS and 20 subjects with seasonal allergic rhinitis without PFAS were enrolled in the study. All the subjects underwent standard skin-prick testing to a panel of common allergens, including select fresh fruits and vegetables. The subjects completed a Mini Rhinoconjunctivitis Quality of Life Questionnaire as part of their clinical evaluation. The subjects with PFAS and those without PFAS were compared statistically. The subjects with PFAS had significantly larger-sized skin-prick test results specific to pollens (p PFAS reported milder nasal symptoms in relation to pollen skin test result size when compared with allergic rhinitis controls without PFAS. Our study outlined basic differences between two seemingly similar patient groups with a particularly striking discordance between skin test result sizes and rhinitis symptoms. This discordance should be explored further to increase mechanistic understanding of allergen cross-reactivity in PFAS.

  8. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  9. Elective penicillin skin testing in a pediatric outpatient setting.

    Jost, Barbara Capes; Wedner, H James; Bloomberg, Gordon R

    2006-12-01

    Adverse reactions associated with penicillin-type antibiotics are common in pediatric practice, leading to the subsequent unnecessary use of alternative antibiotics. IgE-mediated penicillin allergy represents only a fraction of these adverse reactions. To examine (1) the trend of penicillin skin test reactivity during a recent 10-year interval, (2) the relative distribution of specific reagents related to a positive skin test result, and (3) skin test reactivity as a function of reaction history. Penicillin testing using 3 reagents--benzylpenicilloyl polylysine, penicillin G, and sodium penicilloate (penicillin A)--was conducted in a prospective study of 359 consecutive patients referred to an outpatient pediatric allergy clinic between January 1, 1993, and May 31, 2003. We also retrospectively reviewed penicillin skin test results for 562 children previously tested between January 1, 1979, and December 31, 1992. Between 1993 and 2003, the prevalence of penicillin skin test sensitivity markedly declined. Of all the positive skin test results between 1979 and 2002, either penicillin G or sodium penicilloate or both identified 34%, with sodium penicilloate alone responsible for 8.5%. The rate of positive skin test reactions was not significantly different between patients with vs without a history of suggestive IgE-mediated reactions. A marked decline in penicillin skin test sensitivity in the pediatric age group is identified. The minor determinant reagents penicillin G and sodium penicilloate are both necessary for determining potential penicillin allergy. Relating history alone to potential penicillin sensitivity is unreliable in predicting the presence or absence of a positive skin test result.

  10. Analysing sensory panel performance in a proficiency test using the PanelCheck software

    Tomic, O.; Luciano, G.; Nilsen, A.

    2010-01-01

    Check software, a workflow is proposed that guides the user through the data analysis process. This allows practitioners and non-statisticians to get an overview over panel performances in a rapid manner without the need to be familiar with details on the statistical methods. Visualisation of data analysis...... results plays an important role as this provides a time saving and efficient way of screening and investigating sensory panel performances. Most of the statistical methods used in this paper are available in the open source software PanelCheck, which may be downloaded and used for free....

  11. Method of estimating patient skin dose from dose displayed on medical X-ray equipment with flat panel detector

    Fukuda, Atsushi; Koshida, Kichiro; Togashi, Atsuhiko; Matsubara, Kousuke

    2004-01-01

    The International Electrotechnical Commission (IEC) has stipulated that medical X-ray equipment for interventional procedures must display radiation doses such as air kerma in free air at the interventional reference point and dose area product to establish radiation safety for patients (IEC 60601-2-43). However, it is necessary to estimate entrance skin dose for the patient from air kerma for an accurate risk assessment of radiation skin injury. To estimate entrance skin dose from displayed air kerma in free air at the interventional reference point, it is necessary to consider effective energy, the ratio of the mass-energy absorption coefficient for skin and air, and the backscatter factor. In addition, since automatic exposure control is installed in medical X-ray equipment with flat panel detectors, it is necessary to know the characteristics of control to estimate exposure dose. In order to calculate entrance skin dose under various conditions, we investigated clinical parameters such as tube voltage, tube current, pulse width, additional filter, and focal spot size, as functions of patient body size. We also measured the effective energy of X-ray exposure for the patient as a function of clinical parameter settings. We found that the conversion factor from air kerma in free air to entrance skin dose is about 1.4 for protection. (author)

  12. An in vitro human skin test for assessing sensitization potential.

    Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M

    2016-05-01

    Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Testing for seasonal unit roots in monthly panels of time series

    R.M. Kunst (Robert); Ph.H.B.F. Franses (Philip Hans)

    2009-01-01

    textabstractWe consider the problem of testing for seasonal unit roots in monthly panel data. To this aim, we generalize the quarterly CHEGY test to the monthly case. This parametric test is contrasted with a new nonparametric test, which is the panel counterpart to the univariate RURS test that

  14. Lap Shear Testing of Candidate Radiator Panel Adhesives

    Ellis, David; Briggs, Maxwell; McGowan, Randy

    2013-01-01

    During testing of a subscale radiator section used to develop manufacturing techniques for a full-scale radiator panel, the adhesive bonds between the titanium heat pipes and the aluminum face sheets failed during installation and operation. Analysis revealed that the thermal expansion mismatch between the two metals resulted in relatively large shear stresses being developed even when operating the radiator at moderate temperatures. Lap shear testing of the adhesive used in the original joints demonstrated that the two-part epoxy adhesive fell far short of the strength required. A literature review resulted in several candidate adhesives being selected for lap shear joint testing at room temperature and 398 K, the nominal radiator operating temperature. The results showed that two-part epoxies cured at room and elevated temperatures generally did not perform well. Epoxy film adhesives cured at elevated temperatures, on the other hand, did very well with most being sufficiently strong to cause yielding in the titanium sheet used for the joints. The use of an epoxy primer generally improved the strength of the joint. Based upon these results, a new adhesive was selected for the second subscale radiator section.

  15. Skin test of radiosensitivity. Application to Fanconi anemia

    Dutreix, J.; Gluckman, E.

    1983-01-01

    A test of skin radiosensitivity is described. It is achieved by irradiating small skin fields (15 mm in diameter) with 50 kV X-rays. The radiosensitivity is evaluated from the skin reaction observed for a single acute dose of 8 and 10 Gy; it is considered increased if the reaction for 10 Gy exceeds the desquamation threshold, and scored according to the observed reaction. The test includes an evaluation of the cellular repair, assessed on the comparison of the reactions for single dose and split irradiation. The time of the reaction peak is also reported. Abnormal reactions have been observed on 4 out of 8 patients with Fanconi Anemia

  16. Skin test of radiosensitivity. Application to Fanconi anemia

    Dutreix, J. (Institut Gustave-Roussy, 94 - Villejuif (France)); Gluckman, E. (Centre Hayem, Hopital St.-Louis, 75 Paris (France))

    1983-01-01

    A test of skin radiosensitivity is described. It is achieved by irradiating small skin fields (15 mm in diameter) with 50 kV X-rays. The radiosensitivity is evaluated from the skin reaction observed for a single acute dose of 8 and 10 Gy; it is considered increased if the reaction for 10 Gy exceeds the desquamation threshold, and scored according to the observed reaction. The test includes an evaluation of the cellular repair, assessed on the comparison of the reactions for single dose and split irradiation. The time of the reaction peak is also reported. Abnormal reactions have been observed on 4 out of 8 patients with Fanconi Anemia.

  17. Testing for Marshall-Lerner hypothesis: A panel approach

    Azizan, Nur Najwa; Sek, Siok Kun

    2014-12-01

    The relationship between real exchange rate and trade balances are documented in many theories. One of the theories is the so-called Marshall-Lerner condition. In this study, we seek to test for the validity of Marshall-Lerner hypothesis, i.e. to reveal if the depreciation of real exchange rate leads to the improvement in trade balances. We focus our study in ASEAN-5 countries and their main trade partners of U.S., Japan and China. The dynamic panel data of pooled mean group (PMG) approach is used to detect the Marshall-Lerner hypothesis among ASEAN-5, between ASEAN-5 and U.S., between ASEAN-5 and Japan and between ASEAN-5 and China respectively. The estimation is based on the autoregressive Distributed Lag or ARDL model for the period of 1970-2012. The paper concludes that Marshal Lerner theory does not hold in bilateral trades in four groups of countries. The trade balances of ASEAN5 are mainly determined by the domestic income level and foreign production cost.

  18. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2013 . Scientific Opinion on the substantiation of a health claim related to VeriSol ® P and a change in skin elasticity leading to an improvement in skin function pursuant to Article 13(5) of Regulation (EC) No 1924/2006

    Tetens, Inge

    related to VeriSol®P and a change in skin elasticity leading to an improvement in skin function. The Panel considers that the food, VeriSol®P, which is the subject of the health claim, is sufficiently characterised. The claimed effect proposed by the applicant is “maintenance of skin health, as indicated...... by an increased skin elasticity and a reduction of wrinkles volume”. The target population proposed by the applicant is the general adult population. The Panel considers that a change in skin elasticity leading to an improvement in skin function is a beneficial physiological effect. The applicant presented two...... of VeriSol®P and a change in skin elasticity leading to an improvement in skin function. © European Food Safety Authority, 2013...

  19. Nickel deposited on the skin-visualization by DMG test.

    Julander, Anneli; Skare, Lizbet; Vahter, Marie; Lidén, Carola

    2011-03-01

    Nickel is the most common cause of contact allergy and an important risk factor for hand eczema. Visualization techniques may be powerful in showing exposures. The dimethylglyoxime (DMG) test might be used to establish skin exposure to nickel. To develop and evaluate methods for visualization of nickel on the skin by the DMG test and hand imprints. Nickel solutions at different concentrations were applied in duplicate on the hands in healthy subjects (n = 5). The DMG test and acid wipe sampling for quantification were then performed. Hand imprints were taken after manipulation of nickel-releasing tools (n = 1), and in workers performing their normal tasks (n = 7). The imprints were developed by the DMG test. The DMG test on hands gave positive results in all subjects. The lowest concentration giving rise to a colour change was set to 0.13 µg/cm(2) for DMG testing on skin. DMG test-developed imprints worked well except when hands were heavily contaminated by other particles/dust. The DMG test may be used as a simple and powerful tool for visualization of nickel on skin. DMG test-developed hand imprints may, in the future, be used for semi-quantitative or quantitative exposure assessment. © 2011 John Wiley & Sons A/S.

  20. Why Panel Tests of Purchasing Power Parity Should Allow for Heterogeneous Mean Reversion

    C.G. Koedijk (Kees); B. Tims (Ben); M.A. van Dijk (Mathijs)

    2010-01-01

    textabstractAbstract Recent studies of purchasing power parity (PPP) use panel tests that fail to take into account heterogeneity in the speed of mean reversion across real exchange rates. In contrast to several other severe restrictions of panel models and tests of PPP, the assumption of

  1. Cone calorimeter testing of foam core sandwich panels treated with intumescent paper underneath the veneer (FRV)

    Mark A. Dietenberger; Ali Shalbafan; Johannes Welling

    2017-01-01

    Surfaces of novel foam core sandwich panels were adhered with intumescent fire‐retardant paper underneath the veneers (FRV) to improve their flammability properties. The panels were evaluated by means of cone calorimeter test (ASTM E 1354). Variables tested were different surface layer treatments, adhesives used for veneering, surface layer thicknesses, and processing...

  2. Income and CO2 emissions: Evidence from panel unit root and cointegration tests

    Lee, C.-C.; Lee, J.-D.

    2009-01-01

    This paper re-investigates the stationarity properties of per capita carbon dioxide (CO 2 ) emissions and real Gross Domestic Product (GDP) per capita for 109 countries within seven regional panel sets covering 1971-2003. We apply the recent unit-root test of the panel seemingly unrelated regressions augmented Dickey-Fuller (SURADF) test developed by Breuer et al. [2001. Misleading inferences from panel unit-root tests with an illustration from purchasing power parity. Review of International Economics 9, 482-493; 2002. Series-specific unit-root tests with panel data, Oxford Bulletin of Economics and Statistics 64, 527-546]. The panel SURADF test accounts for the presence of cross-country correlations in the data, and the parameters in the panel specification vary across countries. More importantly, this test allows us to identify how many and which members of the panel contain a unit root. Overall, our empirical results illustrate that real GDP and CO 2 emissions in these countries are a mixture of I(0) and I(1) processes, and that the traditional panel unit-root tests could lead to misleading inferences as well as the conduct of cointegration analysis being perhaps inappropriate. The results of our analysis carry critical implications for the modeling of CO 2 emissions and GDP because of the different orders of integration for the two variables

  3. Reliability of skin testing as a measure of nutritional state

    Forse, R.A.; Christou, N.; Meakins, J.L.; MacLean, L.D.; Shizgal, H.M.

    1981-01-01

    The reliability of skin testing to assess the nutritional state was evaluated in 257 patients who received total parenteral nutrition (TPN). The nutritional state was assessed by determining body composition, by multiple-isotope dilution. Immunocompetence was simultaneously evaluated by skin testing with five recall antigens. These measurements were carried out before and at two-week intervals during TPN. A statistically significant relationship existed between the response to skin testing and the nutritional state. A body composition consistent with malnutrition was present in the anergic patients, while body composition was normal in the patients who reacted normally to skin testing. However, a considerable overlap existed as 43% of the reactive patients were malnourished, and 21% of the anergic patients were normally nourished. Thirty-seven (43%) of the 86 anergic patients converted and became reactive during TPN, and their body composition improved significantly. The remaining 49 anergic patients (57%) did not convert, and their body composition did not change despite similar nutritional support. The principal difference between the two groups of anergic patients was the nature of the therapy administered. In the anergic patients who converted, therapy was aggressive and appropriate, and clinical improvement occurred in 23 (62.2%) of the patients, with a mortality of 5.4%. In the 49 patients who remained anergic, therapy was often inappropriate or unsuccessful, with clinical improvement in only three (6.1%) of the patients and a mortality of 42.8%. The data demonstrated a significant relationship between the response to skin testing and the nutritional state. However, because of the wide overlap, skin testing does not accurately assess a person's nutritional state. The persistence of the anergic state is indicative of a lack of response to therapy

  4. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  5. A Bootstrap Neural Network Based Heterogeneous Panel Unit Root Test: Application to Exchange Rates

    Christian de Peretti; Carole Siani; Mario Cerrato

    2010-01-01

    This paper proposes a bootstrap artificial neural network based panel unit root test in a dynamic heterogeneous panel context. An application to a panel of bilateral real exchange rate series with the US Dollar from the 20 major OECD countries is provided to investigate the Purchase Power Parity (PPP). The combination of neural network and bootstrapping significantly changes the findings of the economic study in favour of PPP.

  6. Testing for bubbles in housing markets: a panel data approach

    Mikhed, V.; Zemčík, Petr

    2009-01-01

    Roč. 38, č. 4 (2009), s. 366-386 ISSN 0895-5638 R&D Projects: GA MŠk LC542 Institutional research plan: CEZ:AV0Z70850503 Keywords : house prices * cointegration * panel data Subject RIV: AH - Economics Impact factor: 0.659, year: 2009

  7. A note on Testing Environmental Kuznets Curves with Panel Data

    E. Dijkgraaf (Elbert); H.R.J. Vollebergh (Herman)

    2003-01-01

    textabstractThis paper casts doubt on empirical results based on panel estimations of an "inverted-U" relationship between per capita GDP and pollution. Using a new data set for OECD countries on carbon dioxide emissions for the period 1960-1997, we find that the crucial assumption of homogeneity

  8. Persistence Heterogeneity Testing in Panels with Interactive Fixed Effects

    Ergemen, Yunus Emre; Velasco, Carlos

    We consider large N,T panel data models with fixed effects, a common factor allowing for cross-section dependence, and persistent data and shocks, which are assumed fractionally integrated. In a basic setup, the main interest is on the fractional parameter of the idiosyncratic component, which...

  9. On the estimation and testing of predictive panel regressions

    Karabiyik, H.; Westerlund, Joakim; Narayan, Paresh

    2016-01-01

    Hjalmarsson (2010) considers an OLS-based estimator of predictive panel regressions that is argued to be mixed normal under very general conditions. In a recent paper, Westerlund et al. (2016) show that while consistent, the estimator is generally not mixed normal, which invalidates standard normal

  10. The local lymph node assay and skin sensitization testing.

    Kimber, Ian; Dearman, Rebecca J

    2010-01-01

    The mouse local lymph node assay (LLNA) is a method for the identification and characterization of skin sensitization hazards. In this context the method can be used both to identify contact allergens, and also determine the relative skin sensitizing potency as a basis for derivation of effective risk assessments.The assay is based on measurement of proliferative responses by draining lymph node cells induced following topical exposure of mice to test chemicals. Such responses are known to be causally and quantitatively associated with the acquisition of skin sensitization and therefore provide a relevant marker for characterization of contact allergic potential.The LLNA has been the subject of exhaustive evaluation and validation exercises and has been assigned Organization for Economic Cooperation and Development (OECD) test guideline 429. Herein we describe the conduct and interpretation of the LLNA.

  11. Food Sensitivity in Children with Acute Urticaria in Skin Prick Test: Single Center Experience

    Hatice Eke Gungor

    2015-11-01

    Full Text Available Aim: Families of children with acute urticaria often think that there is food allergy in children with urticaria and insist for skin tests. In this study, it was aimed to determine whether skin prick tests are necessary in cases presented with acute urticaria, in whom other causes of acute urticaria are excluded. Material and Method: A test panel involving cow milk, egg white, wheat, hazelnut, peanut, soybean, walnut, sesame, and tuna fish antigens was applied to the children presented with acute urticaria between 1 August 2013 and 1 August 2014, in whom other causes of acute urticaria were excluded and suspected food allergy was reported by parents. Results: Overall, 574 children aged 1-14 years were included to the study. Of the patients, sensitization against at least one food antigen was detected in 22.3% (128/574 of the patients. This rate was found to be 31.9% among those younger than 3 years, while 19.3% in those older than 3 years. Overall, sensitization rates against food allergen in panel were as follows: egg white, 7.3%; wheat, 3.3%; cow milk, 2.7%,; sesame, 2.8%; hazelnut, 2.4%; soybean, 2.3%; peanut, 1.9%, walnut, 1.6%; tuna fish, 1.6%. In general, the history of patients wasn%u2019t compatible with food sensitization detected. Discussion: Sensitization to food allergens is infrequent in children presented with acute urticaria, particularly among those older than 3 years despite expressions of parent and skin prick tests seems to be unnecessary unless strongly suggestive history is present.

  12. Convergence Hypothesis: Evidence from Panel Unit Root Test with Spatial Dependence

    Lezheng Liu

    2006-10-01

    Full Text Available In this paper we test the convergence hypothesis by using a revised 4- step procedure of panel unit root test suggested by Evans and Karras (1996. We use data on output for 24 OECD countries over 40 years long. Whether the convergence, if any, is conditional or absolute is also examined. According to a proposition by Baltagi, Bresson, and Pirotte (2005, we incorporate spatial autoregressive error into a fixedeffect panel model to account for not only the heterogeneous panel structure, but also spatial dependence, which might induce lower statistical power of conventional panel unit root test. Our empirical results indicate that output is converging among OECD countries. However, convergence is characterized as conditional. The results also report a relatively lower convergent speed compared to conventional panel studies.

  13. Laser welded steel sandwich panel bridge deck development : finite element analysis and stake weld strength tests.

    2009-09-01

    This report summarizes the analysis of laser welded steel sandwich panels for use in bridge structures and : static testing of laser stake welded lap shear coupons. Steel sandwich panels consist of two face sheets : connected by a relatively low-dens...

  14. Pattern Of Skin Prick Allergy Test Results In Enugu | Mgbor ...

    In this study we report on pattern of allergy prick skin test results found among atopic patients attending the department of otorhinolargngology of the University of Nigeria Teaching Hospital Enugu and Hansa Clinics, Enugu and propose ways of minimizing the exposure of the population to allergens. Material and method

  15. Where to prick the apple for skin testing?

    Vlieg-Boerstra, B. J.; van de Weg, W. E.; van der Heide, S.; Dubois, A. E. J.

    Mal d 1 is not equally distributed over the apple. We aimed to examine the influence of the location of pricking in the apple on prick-to-prick skin prick test (PTP) results. PTPs were performed in autumn 2007 and spring 2008, before the birch pollen season, in 32 Dutch adults with symptoms of oral

  16. Erythema exsudativum multiforme after a Leishmania skin test

    Wind, Bas S.; Guimarães, Luiz H.; Machado, Paulo R. L.

    2014-01-01

    A 45-year-old otherwise healthy male from an endemic region for Leishmania braziliensis infection in Bahia, Brazil, presented with three erosive hemorrhagic infiltrated plaques on the left shin accompanied with lymphadenopathy in the groin since one month. A Leishmania skin test performed on the

  17. Where to prick the apple for skin testing?

    Vlieg-Boerstra, B.J.; Weg, van de W.E.; Heide, van der S.; Dubois, A.E.J.

    2013-01-01

    Mal d 1 is not equally distributed over the apple. We aimed to examine the influence of the location of pricking in the apple on prick-to-prick skin prick test (PTP) results. PTPs were performed in autumn 2007 and spring 2008, before the birch pollen season, in 32 Dutch adults with symptoms of oral

  18. Experimental Test for Benchmark 1--Deck Lid Inner Panel

    Xu Siguang; Lanker, Terry; Zhang, Jimmy; Wang Chuantao

    2005-01-01

    The Benchmark 1 deck lid inner is designed for both aluminum and steel based on a General Motor Corporation's current vehicle product. The die is constructed with a soft tool material. The die successfully produced aluminum and steel panels without splits and wrinkles. Detailed surface strains and thickness measurement were made at selected sections to include a wide range of deformation patterns from uniaxial tension mode to bi-axial tension mode. The springback measurements were done by using CMM machine along the part's hem edge which is critical to correct dimensional accuracy. It is expected that the data obtained will provide a useful source for forming and springback study on future automotive panels

  19. Skin test reactivity among Danish children measured 15 years apart

    Thomsen, SF; Ulrik, Charlotte Suppli; Porsbjerg, C

    2006-01-01

    BACKGROUND: Knowledge of secular trends in the prevalence of allergy among children stems in large part from questionnaire surveys, whereas repeated cross-sectional studies using objective markers of atopic sensitization are sparse. OBJECTIVES: To investigate whether the prevalence of skin prick...... (n = 527) and the second in 2001 (n = 480). Skin test reactivity to nine common aeroallergens was measured at both occasions. RESULTS: The prevalence of positive SPT to at least one allergen decreased from 24.1% in 1986 to 18.9% in 2001, (p = 0.05). We found a declining prevalence of sensitization...

  20. Coal consumption and economic growth nexus: Evidence from bootstrap panel Granger causality test

    Anoruo Emmanuel

    2017-01-01

    Full Text Available This paper explores the causal relationship between coal consumption and economic growth for a panel of 15 African countries using bootstrap panel Granger causality test. Specifically, this paper uses the Phillips-Perron unit root test to ascertain the order of integration for the coal consumption and economic growth series. A bootstrap panel Granger causality test is employed to determine the direction of causality between coal consumption and economic growth. The results provide evidence of unidirectional causality from economic growth to coal consumption. This finding implies that coal conservation measures may be implemented with little or no adverse impact on economic growth for the sample countries as a group.

  1. Correlation Results for a Mass Loaded Vehicle Panel Test Article Finite Element Models and Modal Survey Tests

    Maasha, Rumaasha; Towner, Robert L.

    2012-01-01

    High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons

  2. Sporotrichin Skin Test for the Diagnosis of Sporotrichosis.

    Bonifaz, Alexandro; Toriello, Conchita; Araiza, Javier; Ramírez-Soto, Max C; Tirado-Sánchez, Andrés

    2018-05-09

    Sporotrichosis is the most common implantation mycosis caused by several species of the Sporothrix schenckii complex. The gold standard for diagnosis is concerned with the isolation of the fungus; although, fresh examinations, staining, and biopsies are also helpful for this purpose. The sporotrichin is an antigenic complex comprised of a peptide-rhamnomannan, which is relevant with respect to pathogenic fungi; it is primarily used for serological and skin testing. We present a study regarding the use of sporotrichin as a diagnostic aid for cutaneous sporotrichosis. Furthermore, 138 cases with suspicion of sporotrichosis were included, 55 of which were proven through cultures. Moreover, out of these 55 cases, 52 (94.5%) tested positive for sporotrichin, while the negative cases corresponded to the disseminated cutaneous forms. We observed a sensitivity of 94.5% and a specificity of 95.2%. We consider that the use of sporotrichin as a skin test helps us as an auxiliary diagnosis before a positive sample culture.

  3. Validation of artificial skin equivalents as in vitro testing systems

    Schmitt, Robert; Marx, Ulrich; Walles, Heike; Schober, Lena

    2011-03-01

    With the increasing complexity of the chemical composition of pharmaceuticals, cosmetics and everyday substances, the awareness of potential health issues and long term damages for humanoid organs is shifting into focus. Artificial in vitro testing systems play an important role in providing reliable test conditions and replacing precarious animal testing. Especially artificial skin equivalents ASEs are used for a broad spectrum of studies like penetration, irritation and corrosion of substances. One major challenge in tissue engineering is the qualification of each individual ASE as in vitro testing system. Due to biological fluctuations, the stratum corneum hornified layer of some ASEs may not fully develop or other defects might occur. For monitoring these effects we developed an fully automated Optical Coherence Tomography device. Here, we present different methods to characterize and evaluate the quality of the ASEs based on image and data processing of OCT B-scans. By analysing the surface structure, defects, like cuts or tears, are detectable. A further indicator for the quality of the ASE is the morphology of the tissue. This allows to determine if the skin model has reached the final growth state. We found, that OCT is a well suited technology for automatically characterizing artificial skin equivalents and validating the application as testing system.

  4. VLF Cutler: September 1997 Four-Panel Tests; RADHAZ and Field Strength Measurement

    Hansen, P

    1998-01-01

    The objective of the four panel tests was to provide VLF Cutler with the capability of performing the special painting project and normal maintenance on the bow tie area towers of an inactive array...

  5. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) ; Guidance on the scientific requirements for health claims related to bone, joints, skin and oral health

    Tetens, Inge

    The Panel on Dietetic Products, Nutrition and Allergies (NDA) has been asked by the European Food Safety Authority (EFSA) to draft guidance on the scientific requirements for health claims related to bone, joints, skin, and oral health. This guidance has been drawn from scientific opinions...

  6. Panel Unit Root Tests by Combining Dependent Values: A Comparative Study

    Xuguang Sheng

    2011-01-01

    Full Text Available We conduct a systematic comparison of the performance of four commonly used value combination methods applied to panel unit root tests: the original Fisher test, the modified inverse normal method, Simes test, and the modified truncated product method (TPM. Our simulation results show that under cross-section dependence the original Fisher test is severely oversized, but the other three tests exhibit good size properties. Simes test is powerful when the total evidence against the joint null hypothesis is concentrated in one or very few of the tests being combined, but the modified inverse normal method and the modified TPM have good performance when evidence against the joint null is spread among more than a small fraction of the panel units. These differences are further illustrated through one empirical example on testing purchasing power parity using a panel of OECD quarterly real exchange rates.

  7. A research program to reduce interior noise in general aviation airplanes. Design of an acoustic panel test facility

    Roskam, J.; Muirhead, V. U.; Smith, H. W.; Henderson, T. D.

    1977-01-01

    The design, construction, and costs of a test facility for determining the sound transmission loss characteristics of various panels and panel treatments are described. The pressurization system and electronic equipment used in experimental testing are discussed as well as the reliability of the facility and the data gathered. Tests results are compared to pertinent acoustical theories for panel behavior and minor anomalies in the data are examined. A method for predicting panel behavior in the stiffness region is also presented.

  8. Membrane properties for permeability testing: Skin versus synthetic membranes.

    Haq, Anika; Dorrani, Mania; Goodyear, Benjamin; Joshi, Vivek; Michniak-Kohn, Bozena

    2018-03-25

    Synthetic membranes that are utilized in diffusion studies for topical and transdermal formulations are usually porous thin polymeric sheets for example cellulose acetate (CA) and polysulfones. In this study, the permeability of human skin was compared using two synthetic membranes: cellulose acetate and Strat-M® membrane and lipophilic and hydrophilic compounds either as saturated or formulated solutions as well as marketed dosage forms. Our data suggests that hydrophilic compounds have higher permeation in Strat-M membranes compared with lipophilic ones. High variation in permeability values, a typical property of biological membranes, was not observed with Strat-M. In addition, the permeability of Strat-M was closer to that of human skin than that of cellulose acetate (CA > Strat-M > Human skin). Our results suggest that Strat-M with little or no lot to lot variability can be applied in pilot studies of diffusion tests instead of human skin and is a better substitute than a cellulose acetate. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Panel manipulation in social stress testing:The Bath experimental stress test for children (BEST-C)

    Cheetham, Tara J.; Turner-Cobb, Julie M.

    2016-01-01

    BackgroundWhilst acute stress paradigms in adults make use of adult panel members, similar paradigms modified for child participants have not manipulated the panel. Most work has utilised an audience of adult confederates, regardless of the age of the population being tested. The aim of this study was to trial a social stress test for children that provided a meaningful environment using age-matched child peers as panel actors.MethodsThirty-three participants (7-11 years) underwent the Bath E...

  10. 575 Photoaging Attenuates Skin Test Response to Histamine More Than Natural Aging

    King, Monroe James; Fitzhugh, David; Lockey, Richard F.

    2012-01-01

    Background Clinical experience suggests that skin test reactivity is often decreased in photo-exposed skin versus sun-protected skin in older individuals. The current study was designed to address whether photoaging or natural aging of skin causes a greater diminution in skin test reponse. Methods Prick-puncture skin tests to histamine were performed on sun-exposed and sun-protected areas in younger (n = 61, age 20–50) and older (n = 63, age 60–87) adult volunteers who were recruited for skin...

  11. Tuberculosis skin testing, anergy and protein malnutrition in Peru.

    Pelly, T F; Santillan, C F; Gilman, R H; Cabrera, L Z; Garcia, E; Vidal, C; Zimic, M J; Moore, D A J; Evans, C A

    2005-09-01

    Malnutrition and intestinal parasites cause immunosuppression. This may cause false-negative tuberculin skin tests (TST) and failure to identify tuberculosis (TB) infection. To assess factors associated with TST positivity and anergy in disadvantaged communities in Peru. A study of 212 randomly selected adults: 102 in a rural Amazonian village and 110 shanty town residents in urban Lima. Respectively 52% and 53% of urban and rural jungle populations were TST-positive. Using simultaneous tetanus and candida skin tests, 99% had at least one positive skin test. Generalised anergy was therefore rare, despite frequent intestinal parasitic infection, including 34% helminth infection prevalence in the jungle. TST positivity was associated with age (P = 0.001), known TB contact (P = 0.02) and poor household ventilation (P = 0.007). TST positivity was not significantly associated with crowding, reported past TB, single/multiple BCG vaccination, income, intestinal parasites, dietary factors, body mass index or body fat. Individuals with lower anthropometric body protein, as measured by corrected arm muscle area, were less likely to be TST-positive (P = 0.02), implying that protein malnutrition caused tuberculin-specific anergy. These results identify the importance of household ventilation for community TB transmission and add to the evidence that protein malnutrition suppresses TB immunity, causing false-negative TST results.

  12. Radiant heating tests of several liquid metal heat-pipe sandwich panels

    Camarda, C.J.; Basiulis, A.

    1983-08-01

    Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors

  13. Comprehensive embryo testing. Experts' opinions regarding future directions: an expert panel study on comprehensive embryo testing.

    Hens, Kristien; Dondorp, Wybo J; Geraedts, Joep P M; de Wert, Guido M

    2013-05-01

    What do scientists in the field of preimplantation genetic diagnosis (PGD) and preimplantation genetic screening (PGS) consider to be the future direction of comprehensive embryo testing? Although there are many biological and technical limitations, as well as uncertainties regarding the meaning of genetic variation, comprehensive embryo testing will impact the IVF/PGD practice and a timely ethical reflection is needed. Comprehensive testing using microarrays is currently being introduced in the context of PGD and PGS, and it is to be expected that whole-genome sequencing will also follow. Current ethical and empirical sociological research on embryo testing focuses on PGD as it is practiced now. However, empirical research and systematic reflection regarding the impact of comprehensive techniques for embryo testing is missing. In order to understand the potential of this technology and to be able to adequately foresee its implications, we held an expert panel with seven pioneers in PGD. We conducted an expert panel in October 2011 with seven PGD pioneers from Belgium, The Netherlands, Germany and the UK. Participants expected the use of comprehensive techniques in the context of PGD. However, the introduction of these techniques in embryo testing requires timely ethical reflection as it involves a shift from choosing an embryo without a particular genetic disease (i.e. PGD) or most likely to result in a successful pregnancy (i.e. PGS) to choosing the best embryo based on a much wider set of criteria. Such ethical reflection should take account of current technical and biological limitations and also of current uncertainties with regard to the meaning of genetic variance. However, ethicists should also not be afraid to look into the future. There was a general agreement that embryo testing will be increasingly preceded by comprehensive preconception screening, thus enabling smart combinations of genetic testing. The group was composed of seven participants from

  14. Skin Sensitive Difference of Human Body Sections under Clothing-Smirnov Test of Skin Surface Temperatures' Dynamic Changing

    LI Jun; WU Hai-yan; WANG Yun-yi

    2004-01-01

    Skin sensitive difference of human body sections under clothing is the theoretic foundation of thermal insulation clothing design.By a new method of researching on clothing comfort perception,the skin temperature live changing procedure of human body sections affected by the same cold stimulation is inspected.Furthermore with the Smirnov test the skin temperatures dynamic changing patterns of main human body sections are obtained.

  15. Laboratory Testing of Precast Bridge Beck Panel Transverse Connections for Use in Accelerated Bridge Construction

    Porter, Scott D.

    2009-01-01

    Precast concrete bridge deck panels have been used for decades to accelerate bridge construction. Cracking of the transverse connection between panels is a common problem that can damage deck overlays and cause connection leaking leading to corrosion of lower bridge elements. To better understand the behavior of bridge deck transverse female-to-female connections, shear and moment lab testing were performed at Utah State University for the Utah Department of Transportation. Two existing UDOT ...

  16. A Panel Test of Purchasing Power Parity Under the Null of Stationarity

    Hunter, J; Simpson, M

    2001-01-01

    Purchasing Power Parity (PPP) is tested using a sample of real exchange rate data for twelve European countries. Acknowledging that Augmented Dickey Fuller tests have low power, we apply a Panel test that considers the null of stationarity and corrects for serial dependence using a non-parametric kernel based method.

  17. [Characteristics of allergic conjunctivitis with positive skin prick test].

    Yang, S; Jiang, Y; Jin, Y M; Zhang, J Y; Li, Y

    2017-09-11

    Objective: To observe the clinical characteristics of allergic conjunctivitis, and the correlations with skin prick test results. Methods: A retrospective study. Forty patients with positive skin prick test result were included. Patients underwent an ophthalmologic examination to identify their primary presenting signs and symptoms. The allergy types were divided into 5 groups. All dates were analyzed for the dependence, normality and homogeneity of variance. Chi-square test, Mann-Whitney U test, Kruskal-Wallis H test and Spearman correlation analysis were performed accordingly. Results: Among 40 patients, 18(45.0%) had a clinical diagnosis of seasonal allergic conjunctivitis, 14(35.0%) had perennial allergic conjunctivitis, 5(12.5%) had vernal keratoconjunctivitis, and 2(5.0%) had atopic keratoconjunctivits, and 1(2.5%) had giant papillary conjunctivitis. There was no significant difference in the number of symptoms and signs score among different types of allergic conjunctivitis, the score of itching and hyperemia had a positive relationship with the number of positive allergens ( r =0.74, Ptest of the allergen, the more symptoms and signs encountered in terms of severity. Conclusion: Seasonal allergic conjunctivitis was the most prevalent disorder, the most important clinical characteristics of allergic conjunctivitis are itching and conjunctival congestion, the main allergens are dust and pollens, patients may be sensitive to multiple allergens. (Chin J Ophthalmol, 2017, 53: 689-693) .

  18. Solar concentrator panel and gore testing in the JPL 25-foot space simulator

    Dennison, E. W.; Argoud, M. J.

    1981-01-01

    The optical imaging characteristics of parabolic solar concentrator panels (or gores) have been measured using the optical beam of the JPL 25-foot space simulator. The simulator optical beam has been characterized, and the virtual source position and size have been determined. These data were used to define the optical test geometry. The point source image size and focal length have been determined for several panels. A flux distribution of a typical solar concentrator has been estimated from these data. Aperture photographs of the panels were used to determine the magnitude and characteristics of the reflecting surface errors. This measurement technique has proven to be highly successful at determining the optical characteristics of solar concentrator panels.

  19. Experimental vibroacoustic testing of plane panels using synthesized random pressure fields.

    Robin, Olivier; Berry, Alain; Moreau, Stéphane

    2014-06-01

    The experimental reproduction of random pressure fields on a plane panel and corresponding induced vibrations is studied. An open-loop reproduction strategy is proposed that uses the synthetic array concept, for which a small array element is moved to create a large array by post-processing. Three possible approaches are suggested to define the complex amplitudes to be imposed to the reproduction sources distributed on a virtual plane facing the panel to be tested. Using a single acoustic monopole, a scanning laser vibrometer and a baffled simply supported aluminum panel, experimental vibroacoustic indicators such as the Transmission Loss for Diffuse Acoustic Field, high-speed subsonic and supersonic Turbulent Boundary Layer excitations are obtained. Comparisons with simulation results obtained using a commercial software show that the Transmission Loss estimation is possible under both excitations. Moreover and as a complement to frequency domain indicators, the vibroacoustic behavior of the panel can be studied in the wave number domain.

  20. Advanced Development of Leishmania Topical Skin Test Antigen

    2012-09-28

    was discarded. The lysate was then heated in a water bath for 30 minutes at 60°C. The material was cooled to 10 °C, poured into sterile centrifuge...followed to assess the effectiveness of the cleaning and sanitization procedures. The filling, capping and assembly of final containers occurred in Class...40 and 80 µg doses per 0.1 mL. For all skin tests, 0.1 mL was injected intradermally into the volar surface of the forearm . Final LtSTA Report for

  1. Safety panel and new procedures evaluation by simulator tests

    Meslin, T.

    1986-01-01

    With more than thirty weeks of simulator testing (for the last three years only) and approximately three hundred scenarios, EDF's experience in this field is extensive. This practice is well known within Fossil and Nuclear Generation and is well accepted by the operating teams which participate in it. Simulator testing appears to be an essential decision-making tool in the process of developing new operating aids in PWR plants. Accelerated development and the elimination of long and expensive modifications after commissioning is an economic advantage. The saving in time is obvious, since modifications are carried out continuously throughout the development phase. Finally, operators participate in the development of systems and receive fixed, well-defined applications. This practice has become systematic, and all new applications concerning the operation of PWR plants are simulator-tested, particularly 1300-MW unit computers and operating procedures, the new generation of 900-MW unit computers, and the new 1500-MW fully computerized control rooms. Finally, this simulator testing allows us to considerably increase our knowledge concerning the behavior of operators in accident situations, and special tests are performed for this purpose

  2. Evaluation of farmed cod products by a trained sensory panel and consumers in different test settings

    Sveinsdottir, K.; Martinsdottir, E.; Thorsdottir, F.; Schelvis-Smit, A.A.M.; Kole, A.; Thorsdottir, I.

    2010-01-01

    Sensory characteristics of farmed cod exposed to low or conventional stress levels prior to slaughter were evaluated by a trained sensory panel. Consumers in two different settings, central location test (CLT) and home-use test (HUT), also tasted the products and rated them according to overall

  3. Sporotrichin Skin Test for the Diagnosis of Sporotrichosis

    Alexandro Bonifaz

    2018-05-01

    Full Text Available Sporotrichosis is the most common implantation mycosis caused by several species of the Sporothrix schenckii complex. The gold standard for diagnosis is concerned with the isolation of the fungus; although, fresh examinations, staining, and biopsies are also helpful for this purpose. The sporotrichin is an antigenic complex comprised of a peptide-rhamnomannan, which is relevant with respect to pathogenic fungi; it is primarily used for serological and skin testing. We present a study regarding the use of sporotrichin as a diagnostic aid for cutaneous sporotrichosis. Furthermore, 138 cases with suspicion of sporotrichosis were included, 55 of which were proven through cultures. Moreover, out of these 55 cases, 52 (94.5% tested positive for sporotrichin, while the negative cases corresponded to the disseminated cutaneous forms. We observed a sensitivity of 94.5% and a specificity of 95.2%. We consider that the use of sporotrichin as a skin test helps us as an auxiliary diagnosis before a positive sample culture.

  4. Unit Root Testing in Heteroscedastic Panels Using the Cauchy Estimator

    Demetrescu, Matei; Hanck, Christoph

    The Cauchy estimator of an autoregressive root uses the sign of the first lag as instrumental variable. The resulting IV t-type statistic follows a standard normal limiting distribution under a unit root case even under unconditional heteroscedasticity, if the series to be tested has no

  5. Solar panel acceptance testing using a pulsed solar simulator

    Hershey, T. L.

    1977-01-01

    Utilizing specific parameters as area of an individual cell, number in series and parallel, and established coefficient of current and voltage temperature dependence, a solar array irradiated with one solar constant at AMO and at ambient temperature can be characterized by a current-voltage curve for different intensities, temperatures, and even different configurations. Calibration techniques include: uniformity in area, depth and time, absolute and transfer irradiance standards, dynamic and functional check out procedures. Typical data are given for individual cell (2x2 cm) to complete flat solar array (5x5 feet) with 2660 cells and on cylindrical test items with up to 10,000 cells. The time and energy saving of such testing techniques are emphasized.

  6. Identification of low allergenic apple cultivars using skin prick tests and oral food challenge tests

    Vlieg-Boerstra, B.J.; Weg, van de W.E.; Heide, van der S.; Arens, P.F.P.; Heijerman-Peppelman, G.; Dubois, A.E.J.

    2011-01-01

    Background: As oral allergy syndrome (OAS) symptoms to apple are frequent, we aimed to identify low allergenic apple cultivars and to validate the prick-to-prick skin prick test (SPT) as a suitable screening method. Methods: Sixty-eight apple cultivars were tested by SPTs in 33 Dutch adults with

  7. EPA Releases Draft Policy to Reduce Animal Testing for Skin Sensitization

    The document, Draft Interim Science Policy: Use of Alternative Approaches for Skin Sensitization as a Replacement for Laboratory Animal Testing, describes the science behind the non-animal alternatives that can now be used to identify skin sensitization.

  8. Low frequency noise as a control test for spacial solar panels

    Orsal, B.; Alabedra, R.; Ruas, R.

    1986-07-01

    The present study of low frequency noise in a forward-biased dark solar cell, in order to develop an NDE test method for solar panels, notes that a single cell with a given defect is thus detectable under dark conditions. The test subject was a space solar panel consisting of five cells in parallel and five in series; these cells are of the n(+)-p monocrystalline Si junction type. It is demonstrated that the noise associated with the defective cell is 10-15 times higher than that of a good cell. Replacement of a good cell by a defective one leads to a 30-percent increase in the noise level of the panel as a whole.

  9. Corrosion Modeling and Testing of Riveted Aluminum Alloy Panel

    2012-08-28

    Curve Measurement • V-I measurement using rotating disk electrode ( RDE ) captures mass transport contribution • Mass transport can be important for...curve measurement needed Rotating Disk Electrode ( RDE ) y = 0.0353x + 0.1796 0 10 20 30 40 50 60 70 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 5 10 15 B ou nd...ar y la ye r t hi ck ne ss , um D iff us io n Li m ite d C ur re nt ( m A /c m 2 ) Rotation Rate, w1/2 (radian s-1)1/2 Cu RDE Tests IL, mA

  10. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  11. Testing Cross-Sectional Correlation in Large Panel Data Models with Serial Correlation

    Badi H. Baltagi

    2016-11-01

    Full Text Available This paper considers the problem of testing cross-sectional correlation in large panel data models with serially-correlated errors. It finds that existing tests for cross-sectional correlation encounter size distortions with serial correlation in the errors. To control the size, this paper proposes a modification of Pesaran’s Cross-sectional Dependence (CD test to account for serial correlation of an unknown form in the error term. We derive the limiting distribution of this test as N , T → ∞ . The test is distribution free and allows for unknown forms of serial correlation in the errors. Monte Carlo simulations show that the test has good size and power for large panels when serial correlation in the errors is present.

  12. Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing FINAL REPORT

    McDowell, Michael W [Pratt & Whitney Rocketdyne; Miner, Kris [Pratt & Whitney Rocketdyne

    2013-03-30

    The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then complete the fabrication and testing of key components of the receive design that will be used to validate the design. This project shall have a significant impact on solar thermal power plant design. Receiver panels of suitable size for utility scale plants are a key element to a solar power tower plant. Many subtle and complex manufacturing processes are involved in producing a reliable, robust receiver panel. Given the substantial size difference between receiver panels manufactured in the past and those needed for large plant designs, the manufacture and demonstration on prototype receiver panel components with representative features of a full-sized panel will be important to improving the build process for commercial success. Given the thermal flux limitations of the test facility, the panel components cannot be rendered full size. Significance changes occurred in the projects technical strategies from project initiation to the accomplishments described herein. The initial strategy was to define cost improvements for the receiver, design and build a scale prototype receiver and test, on sun, with a molten salt heat transport system. DOE had committed to constructing a molten salt heat transport loop to support receiver testing at the top of the NSTTF tower. Because of funding constraints this did not happen. A subsequent plan to

  13. Expanding the genotype-phenotype spectrum in hereditary colorectal cancer by gene panel testing

    Rohlin, Anna; Rambech, Eva; Kvist, Anders

    2017-01-01

    Hereditary syndromes causing colorectal cancer include both polyposis and non-polyposis syndromes. Overlapping phenotypes between the syndromes have been recognized and this make targeted molecular testing for single genes less favorable, instead there is a gaining interest for multi-gene panel...

  14. Electrical design for origami solar panels and a small spacecraft test mission

    Drewelow, James; Straub, Jeremy

    2017-05-01

    Efficient power generation is crucial to the design of spacecraft. Mass, volume, and other limitations prevent the use of traditional spacecraft support structures from being suitable for the size of solar array required for some missions. Folding solar panel / panel array systems, however, present a number of design challenges. This paper considers the electrical design of an origami system. Specifically, it considers how to provide low impedance, durable channels for the generated power and the electrical aspects of the deployment system and procedure. The ability to dynamically reconfigure the electrical configuration of the solar cells is also discussed. Finally, a small satellite test mission to demonstrate the technology is proposed, before concluding.

  15. Plasma Panel Detectors for MIP Detection for the SLHC and a Test Chamber Design

    Ball, Robert; Etzion, Erez; Friedman, Peter S; Levin, Daniel S; Moshe, Meny Ben; Weaverdyck, Curtis; Zhou, Bing

    2010-01-01

    Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays. The design and production of PDPs is supported by four decades of industrial development. Emerging from this television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally an array of micro-Geiger plasma discharge cells operating in a non-ageing, hermetically sealed gas mixture . We report on the PPS development program, including design of a PPS Test Cell.

  16. Skin prick test reactivity to aeroallergens by filaggrin mutation status

    Hougaard, M G; Johansen, J D; Linneberg, A

    2014-01-01

    BACKGROUND: Studies have shown that filaggrin gene (FLG) mutations are positively associated with sensitization to aero allergens. We hypothesized that FLG mutations would also have an effect on the mean size of positive skin prick test (SPT) reactions as well as the number of positive reactions....... OBJECTIVE: To investigate the effect of FLG mutations on the mean size and the number of positive SPT reactions, as well as the association with positive specific IgE. METHODS: A random sample of 3335 adults from the general population in Denmark was genotyped for the R501X and 2282del4 mutations in the FLG...... mutations alone are insufficient to cause secondary sensitization to allergens. The positive association seen in patients must be explained by a combination of further barrier abnormality caused by dermatitis as well as increased allergen exposure....

  17. Standardization of food allergen extracts for skin prick test

    Skamstrup Hansen, K; Bindslev-Jensen, C; Skov, P S

    2001-01-01

    The aim of the study was to standardize and evaluate technically optimized food allergen extracts for use in skin prick test (SPT). The standardization procedure comprised 36 allergic histories in 32 food allergic patients with 21 healthy, non-atopic individuals serving as controls. The patients...... had a history of allergic symptoms upon ingestion of either cow's milk (n=3), hen's egg (n=9), wheat (n=4), hazelnut (n=14) or cod (n=6). They also had specific IgE in serum to the food in question and a positive SPT with a fresh preparation of the food. The diagnosis had been confirmed by a double......-blind, placebo-controlled food challenge, except for the hazelnut-allergic patients. The controls were subjected to an open food challenge with all the foods to ensure tolerance. The standardization was performed by means of titrated SPT in accordance with the guidelines on biological standardization from...

  18. Wearable device for skin contact thermography: design, construction and testing

    Giansanti, D.; Maccioni, G.

    2008-01-01

    The need for wearable devices for thermal monitoring is rising. These devices could be used to continuously monitor patients for breast cancer investigation or vascular, dermatological and rheumatic disorders, in viability studies, or during physical exercise. We designed and constructed a wearable device for skin-contact thermography that uses integrated silicon sensors. The device was validated using a phantom with a dynamic bench test. The thermal resolution was greater than 0.030'C, and the spatial resolution was equal to 1.6x10-5 m'2. We also investigated the device's performance on five clinical subjects. Results of these studies showed a maximal error of less than 0.10'C in each evaluation [it

  19. AXAF-I Low Intensity-Low Temperature (LILT) Testing of the Development Verification Test (DVT) Solar Panel

    Alexander, Doug; Edge, Ted; Willowby, Doug

    1998-01-01

    The planned orbit of the AXAF-I spacecraft will subject the spacecraft to both short, less than 30 minutes for solar and less than 2 hours for lunar, and long earth eclipses and lunar eclipses with combined conjunctive duration of up to 3 to 4 hours. Lack of proper Electrical Power System (EPS) conditioning prior to eclipse may cause loss of mission. To avoid this problem, for short eclipses, it is necessary to off-point the solar array prior to or at the beginning of the eclipse to reduce the battery state of charge (SOC). This yields less overcharge during the high charge currents at sun entry. For long lunar eclipses, solar array pointing and load scheduling must be tailored for the profile of the eclipse. The battery SOC, loads, and solar array current-voltage (I-V) must be known or predictable to maintain the bus voltage within acceptable range. To address engineering concerns about the electrical performance of the AXAF-I solar array under Low Intensity and Low Temperature (LILT) conditions, Marshall Space Flight Center (MSFC) engineers undertook special testing of the AXAF-I Development Verification Test (DVT) solar panel in September-November 1997. In the test the DVT test panel was installed in a thermal vacuum chamber with a large view window with a mechanical "flapper door". The DVT test panel was "flash" tested with a Large Area Pulse Solar Simulator (LAPSS) at various fractional sun intensities and panel (solar cell) temperatures. The testing was unique with regards to the large size of the test article and type of testing performed. The test setup, results, and lessons learned from the testing will be presented.

  20. Advances in the diagnosis of hereditary kidney cancer: Initial results of a multigene panel test.

    Nguyen, Kevin A; Syed, Jamil S; Espenschied, Carin R; LaDuca, Holly; Bhagat, Ansh M; Suarez-Sarmiento, Alfredo; O'Rourke, Timothy K; Brierley, Karina L; Hofstatter, Erin W; Shuch, Brian

    2017-11-15

    Panel testing has been recently introduced to evaluate hereditary cancer; however, limited information is available regarding its use in kidney cancer. The authors retrospectively reviewed test results and clinical data from patients who underwent targeted multigene panel testing of up to 19 genes associated with hereditary kidney cancer from 2013 to 2016. The frequency of positive (mutation/variant likely pathogenic), inconclusive (variant of unknown significance), and negative results was evaluated. A logistic regression analysis evaluated predictive factors for a positive test. Patients (n = 1235) had a median age at diagnosis of 46 years, which was significantly younger than the US population of individuals with kidney cancer (P kidney cancer. Panel tests may be particularly useful for patients who lack distinguishing clinical characteristics of known hereditary kidney cancer syndromes. The current results support the use of early age of onset for genetic counseling and/or testing. Cancer 2017;123:4363-71. © 2017 American Cancer Society. © 2017 American Cancer Society.

  1. The integration of major fuel source markets in China. Evidence from panel cointegration tests

    Ma, Hengyun; Oxley, Les

    2010-01-01

    The paper tests for energy price co-movement in China over the 'new regime' as part of a strategy to test for the existence of a national energy market. Panel cointegration test statistics suggest that not all energy commodities are spatially homogenous in prices and the processes of energy price cointegration are different over time and over groups of fuels. The statistics demonstrate China's gradual, spatially partial and idiosyncratic energy reform process. Coal and electricity price series have co-moved since 2003, while the national panel cointegration test statistics suggest that gasoline and diesel price series have co-moved since 1997. Regional panel tests also show that there are apparently differences in the emergence of energy price co-movement. This suggests that regional energy markets have emerged in China. One of the important lessons of the research is that an energy market has, to some extent, already emerged in China and, as a consequence, energy prices are much less distorted than previously. If correct, this fact is of major global significance both in terms of future environmental effects and future trade and investment negotiations as China is seen internationally as a 'market driven economy'. (author)

  2. A panel Granger-causality test of endogenous vs. exogenous growth

    Jochen Hartwig

    2009-01-01

    The paper proposes a new test of endogenous vs. exogenous growth theories based on the Granger-causality methodology and applies it to a panel of 20 OECD countries. The test yields divergent evidence with respect to physical and human capital. For physical capital, the test results favor Solow-type exogenous growth theory over AK-type endogenous growth models. On the other hand, the test results lend support to human capital oriented endogenous growth models - like the Uzawa-Lucas model - rat...

  3. Properties of fly ash and metakaolín based geopolymer panels under fire resistance tests

    Luna-Galiano, Y.

    2015-09-01

    Full Text Available This paper presents the results of a study about the effect of fire on geopolymer paste composed of fly ashes, metakaolin and sodium silicate. 2 cm thick, 28 cm high and 18 cm wide panels were filled with the paste obtained. After 28 days of curing at 20 °C and 45% of relative humidity, different tests were carried out in the geopolymers: physico-chemical (density, water absorption, porosity, mechanical (flexural and compressive strength, fire resistance and environmental (leaching and radioactivity. The panels manufactured have been compared with other commercial panels in order to determine the recycling possibilities of fly ashes in manufacturing new fire-insulating geopolymers. The panels obtained can be utilized for the production of interior wall materials, with a good physical, mechanical, fire resistant properties without any environmental problem.Este documento presenta los resultados de un estudio sobre el efecto del fuego sobre pastas de geopolímeros compuestas de cenizas volantes, metacaolín y silicato sódico. Con la pasta obtenida se han rellenado paneles de dimensiones 2 cm de espesor, 28 cm de altura y 18 cm de ancho. Tras 28 días de curado a 20 °C y un 45% de humedad relativa, diferentes ensayos fueron realizados en los geopolímeros obtenidos: fisicoquímicos (densidad, absorción de agua, porosidad, mecánicos (resistencia a compresión y a flexión, de resistencia al fuego y medioambientales (lixiviación y radioactividad. Los paneles fabricados han sido comparados con paneles comerciales para determinar las posibilidades de reciclaje de las cenizas volantes para la fabricación de nuevos productos geopoliméricos con propiedades aislantes al fuego. Los paneles obtenidos pueden ser utilizados para la producción de paredes interiores, con buenas propiedades físicas, mecánicas y de resistencia al fuego sin ningún problema medioambiental.

  4. Characteristics of children with positive tuberculin skin test.

    Hocaoğlu, Arzu Babayiğit; Erge, Duygu Olmez; Anal, Ozden; Makay, Balahan; Uzuner, Nevin; Karaman, Ozkan

    2011-01-01

    The aim of the study was to define the characteristics of children with latent tuberculosis diagnosed with positive tuberculin skin test (TST) and evaluate potential risk factors in children with positive TST. Children followed with the diagnosis of latent tuberculosis infection were included in the study retrospectively. Demographic characteristics of patients including history of atopy, respiratory infections, family history of tuberculosis and atopy, number of BCG vaccinations, findings of physical examination and laboratory data were extracted from patient's file. Eighty-one children (51 male, 30 female) who had positive TST were retrospectively evaluated in the study. Mean age of the patients was 8.00 ± 4.00 years. Only 13 (16%) of the children had contact with a case who had active tuberculosis. It was shown that the age of the patients, number of BCG scars and BCG vaccination significantly affected TST reaction size. TST size was not affected with time passed after last dose of BCG vaccination, family history of tuberculosis, presence of TST positive case in the family, exposure to cigarette smoke, number of household family members and presence of respiratory allergic disease. The patient's age, numbers of BCG vaccination and BCG scars significantly affect TST results in childhood. This may cause difficulty in diagnosing latent tuberculosis infection and in decision of initiating prophylactic treatment. The results of this study may show that recently developed, more accurate and convenient in vitro tests that they have higher costs and require sophisticated laboratory, can be used to diagnose latent tuberculosis.

  5. Papain-induced asthma: diagnosis by skin test, RAST and bronchial provocation test

    Baur, X.; Fruhmann, G.

    1979-01-01

    Seven out of eleven workers occupationally exposed to airborne papain developed immediate hypersensitive reactions, predominantly asthma and rhinitis. Skin tests and RAST with papain were positive in all symptomatic workers, but not in the four asymptomatic workers. Furthermore, out of forty non-exposed asthmatics, thirty-eight had negative RAST results and all had negative skin test results. Bronchial provocation tests with 0.15-0.5 mg papain performed in five patients with a positive case history showed in each case an immediate asthmatic reaction; in addition to that, one patient developed signs of a dual asthmatic reaction. These results suggest that airborne papain is a highly immunogenic agent in humans, which induces type I allergic reactions in a large percentage of the exposed subjects. (author)

  6. The colour of blood in skin: a comparison of Allen's test and photonics simulations.

    Välisuo, Petri; Kaartinen, Ilkka; Kuokkanen, Hannu; Alander, Jarmo

    2010-11-01

    The colour of the skin reflects many physiological and pathological states of an individual. Usually, the skin colour is examined by the bare eye alone. Several scaling systems have been developed to quantify the sensory evaluation of skin colour. In this work, the reflectance of the skin is measured directly using an objective instrument. Haemoglobin inside the dermal circulation is one of the key factors of skin colour and it also has a major role in the appearance of many skin lesions and scars. To quantitatively measure and analyse such conditions, the relation between the skin colour and the haemoglobin concentration in the skin needs to be resolved. To examine the effect of blood concentration on the skin colour, five Allen's tests were performed on 20 persons. The skin colour change was measured using a spectrophotometer by changing the blood concentration by the Allen's test. Light interaction with the skin was simulated with a Monte Carlo model, tuning the blood concentration parameter until the simulated and the measured spectra matched, yielding the relationship between the skin colour and the blood concentration. The simulation produced spectra similar to those measured. The change in the blood concentration in the simulation model and in the skin produced changes similar to the spectra. The reflectance of the skin was found to be a nonlinear function of the blood concentration. The relationship found between skin colour and blood concentration makes it possible to quantify those skin conditions expressed by blood volume better than plain colour. © 2010 John Wiley & Sons A/S.

  7. Testing for Unit Roots in Small Panels with Short-run and Long-run Cross-sectional Dependencies

    Yoosoon Chang; Wonho Song

    2009-01-01

    An IV approach, using as instruments non-linear transformations of the lagged levels, is explored to test for unit roots in panels with general dependency and heterogeneity across cross-sectional units. We allow not only for the cross-sectional dependencies of innovations, but also for the presence of co-integration across cross-sectional levels. Unbalanced panels and panels with differing individual short-run dynamics and cross-sectionally related dynamics are also permitted. We also more ca...

  8. In-Situ Testing and Performance Assessment of a Redesigned WIPP Panel Closure - 13192

    Klein, Thomas [URS-Professional Solutions, 4021 National Parks Highway Carlsbad, NM 88220 (United States); Patterson, Russell [Department of Energy-Carlsbad Field Office, 4021 National Parks Highway Carlsbad, NM 88220 (United States); Camphouse, Chris; Herrick, Courtney; Kirchner, Thomas; Malama, Bwalya; Zeitler, Todd [Sandia National Laboratories-Carlsbad, 4100 National Parks Highway Carlsbad, NM 88220 (United States); Kicker, Dwayne [SM Stoller Corporation-Carlsbad, 4100 National Parks Highway Carlsbad, NM (United States)

    2013-07-01

    operations and a greater understanding of the waste and the behavior of the underground salt formation, the DOE has established a revised panel closure design. This revised design meets both the short-term NMED Permit requirements for the operational period, and also the Federal requirements for long-term repository performance. This new design is simpler, easier to construct and has less of an adverse impact on waste disposal operations than the originally approved Option D design. The Panel Closure Redesign is based on: (1) the results of in-situ constructability testing performed to determine run-of-mine salt reconsolidation parameters and how the characteristics of the bedded salt formation affect these parameters and, (2) the results of air flow analysis of the new design to determine that the limit for the migration of Volatile Organic Compounds (VOCs) will be met at the compliance point. Waste panel closures comprise a repository feature that has been represented in WIPP performance assessment (PA) since the original Compliance Certification Application of 1996. Panel closures are included in WIPP PA models principally because they are a part of the disposal system, not because they play a substantive role in inhibiting the release of radionuclides to the outside environment. The 1998 rulemaking that certified WIPP to receive transuranic waste placed conditions on the panel closure design to be implemented in the repository. The revised panel closure design, termed the Run-of-Mine (ROM) Panel Closure System (ROMPCS), is comprised of 30.48 meters of ROM salt with barriers at each end. The ROM salt is generated from ongoing mining operations at the WIPP and may be compacted and/or moistened as it is emplaced in a panel entry. The barriers consist of bulkheads, similar to those currently used in the panels as room closures. A WIPP performance assessment has been completed that incorporates the ROMPCS design into the representation of the repository, and compares

  9. Simplification of intradermal skin testing in Hymenoptera venom allergic children.

    Cichocka-Jarosz, Ewa; Stobiecki, Marcin; Brzyski, Piotr; Rogatko, Iwona; Nittner-Marszalska, Marita; Sztefko, Krystyna; Czarnobilska, Ewa; Lis, Grzegorz; Nowak-Węgrzyn, Anna

    2017-03-01

    The direct comparison between children and adults with Hymenoptera venom anaphylaxis (HVA) has never been extensively reported. Severe HVA with IgE-documented mechanism is the recommendation for venom immunotherapy, regardless of age. To determine the differences in the basic diagnostic profile between children and adults with severe HVA and its practical implications. We reviewed the medical records of 91 children and 121 adults. Bee venom allergy was exposure dependent, regardless of age (P bee venom allergic group, specific IgE levels were significantly higher in children (29.5 kU A /L; interquartile range, 11.30-66.30 kU A /L) compared with adults (5.10 kU A /L; interquartile range, 2.03-8.30 kU A /L) (P venom were higher in bee venom allergic children compared with the wasp venom allergic children (P venom. At concentrations lower than 0.1 μg/mL, 16% of wasp venom allergic children and 39% of bee venom allergic children had positive intradermal test results. The median tryptase level was significantly higher in adults than in children for the entire study group (P = .002), as well as in bee (P = .002) and wasp venom allergic groups (P = .049). The basic diagnostic profile in severe HVA reactors is age dependent. Lower skin test reactivity to culprit venom in children may have practical application in starting the intradermal test procedure with higher venom concentrations. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  10. Purchasing Power Parity in Transition Countries: Panel Stationary Test with Smooth and Sharp Breaks

    Mohsen Bahmani-Oskooee

    2015-05-01

    Full Text Available This study examines whether the long-run purchasing power parity (PPP holds in transition economies (Bulgaria, the Czech Republic, Hungary, Latvia, Lithuania, Poland, Romania and Russia using monthly data over the 1995–2011 period. We apply a recently introduced panel stationary test, which accounts for sharp breaks and smooth shifts. The results indicate that the PPP holds only in two countries (i.e., Lithuania and Poland.

  11. Qualification test results for DOE solar photovoltaic flat panel procurement - PRDA 38

    Griffith, J. S.

    1980-01-01

    Twelve types of prototypes modules for the DOE Photovoltaic Flat Panel Procurement (PRDA 38) were subjected to qualification tests at the Jet Propulsion Laboratory according to a new specification. Environmental exposures were carried out separately and included temperature cycling, humidity, wind simulation, and hail. The most serious problems discovered were reduced insulation resistance to ground and ground continuity of the metal frames, electrical degradation, erratic power readings, and delamination. The electrical and physical characteristics of the newly received modules are also given.

  12. Extension of the ACE solar panels is tested in SAEF-II

    1997-01-01

    Extension of the solar panels is tested on the Advanced Composition Explorer (ACE) spacecraft in KSC's Spacecraft Assembly and Encapsulation Facility-II (SAEF-II). Scheduled for launch on a Delta II rocket from Cape Canaveral Air Station on Aug. 25, ACE will study low-energy particles of solar origin and high-energy galactic particles. The collecting power of instruments aboard ACE is 10 to 1,000 times greater than anything previously flown to collect similar data by NASA.

  13. A tuberculin skin test survey among Ghanaian school children

    Bonsu Christian

    2010-01-01

    Full Text Available Abstract Background Ghana has not conducted a national tuberculin survey or tuberculosis prevalence survey since the establishment of the National Tuberculosis Control Programme. The primary objective of this study was therefore to determine the prevalence of tuberculin skin sensitivity in Ghanaian school children aged 6-10 years in 8 out of 10 regions of Ghana between 2004 and 2006. Methods Tuberculin survey was conducted in 179 primary schools from 21 districts in 8 regions. Schools were purposively selected so as to reflect the proportion of affluent private and free tuition public schools as well as the proportion of small and large schools. Results Of the 24,778 children registered for the survey, 23,600 (95.2% were tested of which 21,861 (92.6% were available for reading. The age distribution showed an increase in numbers of children towards older age: 11% of the children were 6 years and 25%, 10 years. Females were 52.5% and males 47.5%. The proportion of girls was higher in all age groups (range 51.4% to 54.0%, p Conclusion Tuberculosis infection is still a public health problem in Ghana and to monitor the trend, the survey needs to be repeated at 5 years interval.

  14. Where to prick the apple for skin testing?

    Vlieg-Boerstra, B J; van de Weg, W E; van der Heide, S; Dubois, A E J

    2013-09-01

    Mal d 1 is not equally distributed over the apple. We aimed to examine the influence of the location of pricking in the apple on prick-to-prick skin prick test (PTP) results. PTPs were performed in autumn 2007 and spring 2008, before the birch pollen season, in 32 Dutch adults with symptoms of oral allergy to fresh apple, using apples harvested in autumn 2007. PTPs with fresh intact and unpeeled Pink Lady, Golden Delicious, Elise, Santana and Modi apples were performed using material obtained from approximately 2 cm near the stalk (top), and the middle region. All PTP responses were greater when performed with apple material near the stalk than from the middle region. In 2007, these differences were statistically significant for Pink Lady, Golden Delicious and Elise, and in 2008, for Pink Lady and Modi. When performing PTPs, the apple should be pricked near the stalk rather than in the middle. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Investigation of Energy Absorption in Aluminum Foam Sandwich Panels By Drop Hammer Test: Experimental Results

    Mohammad Nouri Damghani

    2016-05-01

    Full Text Available The sandwich panel structures with aluminum foam core and metal surfaces have light weight with high performance in dispersing energy. This has led to their widespread use in the absorption of energy. The cell structure of foam core is subjected to plastic deformation in the constant tension level that absorbs a lot of kinetic energy before destruction of the structure. In this research, by making samples of aluminum foam core sandwich panels with aluminum surfaces, experimental tests of low velocity impact by a drop machine are performed for different velocities and weights of projectile on samples of sandwich panels with aluminum foam core with relative density of 18%, 23%, and 27%. The output of device is acceleration‐time diagram which is shown by an accelerometer located on the projectile. From the experimental tests, the effect of weight, velocity and energy of the projectile and density of the foam on the global deformation, and energy decrease rate of projectile have been studied. The results of the experimental testes show that by increasing the density of aluminum foam, the overall impression is reduced and the slop of energy loss of projectile increases. Also by increasing the velocity of the projectile, the energy loss increases.

  16. Penicillin skin testing is a safe and effective tool for evaluating penicillin allergy in the pediatric population.

    Fox, Stephanie J; Park, Miguel A

    2014-01-01

    Penicillin skin testing has been validated in the evaluation of adult patients with penicillin allergy. However, the commercially available benzylpenicilloyl polylysine (Pre-Pen) is not indicated in the pediatric population. Moreover, the safety and validity of penicillin skin testing in the pediatric population has not been well studied. We describe the safety and validity of penicillin skin testing in the evaluation of children with a history of penicillin allergy. Children (penicillin allergy were evaluated with penicillin skin tests and were reviewed for basic demographics, penicillin skin test results, adverse drug reaction to penicillin after penicillin skin test, and adverse reaction to penicillin skin test. By using the χ(2) test, we compared the differences in the proportion of children and adults with a positive penicillin skin test. P value (penicillin skin testing; 703 of 778 patients had a negative penicillin skin test (90.4%), 66 had a positive test (8.5%), and 9 had an equivocal test (1.1%). Children were more likely to have a positive penicillin skin test (P penicillin skin test (52%) were challenged with penicillin, and 14 of 369 patients (3.8%) had an adverse drug reaction. No adverse reactions to penicillin skin testing were observed. Penicillin skin testing was safe and effective in the evaluation of children with a history of penicillin allergy. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  17. Penicillin skin testing in the evaluation and management of penicillin allergy.

    Fox, Stephanie; Park, Miguel A

    2011-01-01

    to review the role of penicillin skin testing in the evaluation and management of penicillin allergy mediated by IgE. PubMed and OVID search of English-language articles regarding penicillin allergy, penicillin allergy testing, and management of penicillin allergy. articles pertinent to the subject matter were selected and reviewed. the major determinant (benzylpenicillin polylysine) detects the greatest number of penicillin allergic patients during skin testing, and the minor determinants of penicillin increase the sensitivity of penicillin skin testing. Penicillin skin testing to the major and minor determinants was found to have a negative predictive value of 97% to 99%. The incidence of systemic adverse reaction to penicillin skin testing is less than 1%. a detailed history of the prior reaction to penicillin is an integral part of the evaluation, but it is not accurate in predicting a positive penicillin skin test result. A patient with a negative penicillin skin test result to the major and minor determinants is at a low risk of an immediate-type hypersensitivity reaction to penicillin. Patients with a positive skin test result should undergo desensitization to penicillin or an alternative antibiotic should be considered.

  18. Hepatic (Liver) Function Panel

    ... Educators Search English Español Blood Test: Hepatic (Liver) Function Panel KidsHealth / For Parents / Blood Test: Hepatic (Liver) ... kidneys ) is working. What Is a Hepatic (Liver) Function Panel? A liver function panel is a blood ...

  19. Compatibility of Clinical Manifestation with Skin Prick Test Result and Food Provocation Test in Food Cross Reaction

    Lubis, Azwin; Barlianto, Wisnu; Endaryanto, Anang; Harsono, Ariyanto

    2017-01-01

    Background: Subjective diagnostic test of food allergy is hugely biased, resulting in irrational diet avoidance. Additional objective tools by skin prick test following food provocation test resulting more accurate cause and prevalence on population. Purpose: To evaluate the compatibility of clinical symptoms with skin prick test and provocation test for imunoglobulin E (IgE) mediated food allergy in Dr. Soetomo Hospital Surabaya. Methods: Cross sectional observational analytic study. Patient...

  20. Skin

    Hunter, R.D.

    1985-01-01

    Malignant disease involving the skin represents a significant work load to the general radiotherapist and can involve interesting diagnostic and therapeutic decisions. Primary skin cancer is also relatively common and there is a need to provide an efficient service in which the first treatment is successful in the majority of patients. The reward for careful attention to technique is very considerable both in terms of clinical cancer control and functional results. Squamous cell carcinoma, basal cell carcinoma, and intra-epidermal carcinoma constitute the majority of the lesions dealt with clinically, but metastatic disease, lymphomas, and malignant melanomas are also referred regularly for opinions and may require radiotherapy. The general principle of the techniques of assessment and radiotherapeutic management to be described are equally applicable to any malignant skin tumour once the decision has been made to accept it for radiotherapy. Dosage and fractionation may have to be adjusted to allow for the nature of the disease process and the intent of the treatment

  1. Test and Analysis Correlation of Form Impact onto Space Shuttle Wing Leading Edge RCC Panel 8

    Fasanella, Edwin L.; Lyle, Karen H.; Gabrys, Jonathan; Melis, Matthew; Carney, Kelly

    2004-01-01

    Soon after the Columbia Accident Investigation Board (CAIB) began their study of the space shuttle Columbia accident, "physics-based" analyses using LS-DYNA were applied to characterize the expected damage to the Reinforced Carbon-Carbon (RCC) leading edge from high-speed foam impacts. Forensic evidence quickly led CAIB investigators to concentrate on the left wing leading edge RCC panels. This paper will concentrate on the test of the left-wing RCC panel 8 conducted at Southwest Research Institute (SwRI) and the correlation with an LS-DYNA analysis. The successful correlation of the LS-DYNA model has resulted in the use of LS-DYNA as a predictive tool for characterizing the threshold of damage for impacts of various debris such as foam, ice, and ablators onto the RCC leading edge for shuttle return-to-flight.

  2. Verification test for helium panel of cryopump for DIII-D advanced divertor

    Baxi, C.B.; Laughon, G.J.; Langhorn, A.R.; Schaubel, K.M.; Smith, J.P.; Gootgeld, A.M.; Campbell, G.L.; Menon, M.M.

    1992-01-01

    It is planned to install a cryogenic pump in the lower divertor portion of the DIII-D tokamak with a pumping speed of 50000 ell/s and an exhaust of 2670 Pa-ell/s (20 Torr-ell/s). A coaxial counter flow configuration has been chosen for the helium panel of this cryogenic pump. This paper evaluates cool-down rates and fluid stability of this configuration. A prototypic test was performed at General Atomics (GA) to increase confidence in the design. It was concluded that the helium panel cooldown rate agreed quite well with analytical prediction and was within acceptable limits. The design flow rate proved stable and two-phase pressure drop can be predicted quite accurately

  3. Verification test for helium panel of cryopump for DIII-D advanced divertor

    Baxi, C.B.; Laughon, G.J.; Langhorn, A.R.; Schaubel, K.M.; Smith, J.P.; Gootgeld, A.M.; Campbell, G.L.; Menon, M.M.

    1991-10-01

    It is planned to install a cryogenic pump in the lower divertor portion of the D3-D tokamak with a pumping speed of 50000 ell/s and an exhaust of 2670 Pa-ell/s (20 Torr-ell s). A coaxial counter flow configuration has been chosen for the helium panel of this cryogenic pump. This paper evaluates cooldown rates and fluid stability of this configuration. A prototypic test was performed at General Atomics (GA) to increase confidence in the design. It was concluded that the helium panel cooldown rate agreed quite well with analytical prediction and was within acceptable limits. The design flow rate proved stable and two-phase pressure drop can be predicted quite accurately. 8 refs., 5 figs., 1 tab

  4. Testing solar panels for small-size satellites: the UPMSAT-2 mission

    Roibás-Millán, E; Alonso-Moragón, A; Jiménez-Mateos, A G; Pindado, S

    2017-01-01

    At present, the development of small-size satellites by universities, companies and research institutions has become usual practice, and is spreading rapidly. In this kind of project cost plays a significant role. One of the main areas are the assembly, integration and test (AIT) plans, which carry an associated cost for simulating environmental conditions. For instance, in the power subsystems test and, in particular, in the testing of solar panels, the irradiance and temperature conditions might be optimum so the performance of the system can be shown next to real operational conditions. To reproduce the environmental conditions in terms of irradiance, solar simulators are usually used, which carries an associated increase in cost for testing the equipment. The aim of this paper is to present an alternative and inexpensive way to perform AIT plans on spacecraft power subsystems, from a testing campaign performed using outdoor clean-sky conditions and an isolation system to protect the panels. A post-process of the measured data is therefore needed, taking into account the conditions in which the test has been accomplished. The I–V characteristics obtained are compared with a theoretical 1-diode/2-resistor equivalent electric circuit, achieving enough precision based solely on the manufacturer’s data. (paper)

  5. Testing solar panels for small-size satellites: the UPMSAT-2 mission

    Roibás-Millán, E.; Alonso-Moragón, A.; Jiménez-Mateos, A. G.; Pindado, S.

    2017-11-01

    At present, the development of small-size satellites by universities, companies and research institutions has become usual practice, and is spreading rapidly. In this kind of project cost plays a significant role. One of the main areas are the assembly, integration and test (AIT) plans, which carry an associated cost for simulating environmental conditions. For instance, in the power subsystems test and, in particular, in the testing of solar panels, the irradiance and temperature conditions might be optimum so the performance of the system can be shown next to real operational conditions. To reproduce the environmental conditions in terms of irradiance, solar simulators are usually used, which carries an associated increase in cost for testing the equipment. The aim of this paper is to present an alternative and inexpensive way to perform AIT plans on spacecraft power subsystems, from a testing campaign performed using outdoor clean-sky conditions and an isolation system to protect the panels. A post-process of the measured data is therefore needed, taking into account the conditions in which the test has been accomplished. The I-V characteristics obtained are compared with a theoretical 1-diode/2-resistor equivalent electric circuit, achieving enough precision based solely on the manufacturer’s data.

  6. Insertion Testing of Polyethylene Glycol Microneedle Array into Cultured Human Skin with Biaxial Tension

    Takano, Naoki; Tachikawa, Hiroto; Miyano, Takaya; Nishiyabu, Kazuaki

    Aiming at the practical use of polyethylene glycol (PEG) microneedles for transdermal drug delivery system (DDS), a testing apparatus for their insertion into cultured human skin has been developed. To simulate the variety of conditions of human skin, biaxial tension can be applied to the cultured human skin. An adopted testing scheme to apply and control the biaxial tension is similar to the deep-draw forming technique. An attention was also paid to the short-time setup of small, thin and wet cultured skin. One dimensional array with four needles was inserted and influence of tension was discussed. It was found that tension, deflection of skin during insertion and original curvature of skin are the important parameters for microneedles array design.

  7. Mean reversion in the current account of forty-eight african countries: Evidence from the Panel SURADF test

    Chu, Hsiao-Ping; Chang, Tsangyao; Chang, Hsu-Ling; Su, Chi-Wei; Yuan, Young

    2007-10-01

    Here, the Panel seemingly unrelated regressions augmented Dickey-Fuller test (SURADF) test, first introduced and advanced by Breuer et al. [Misleading inferences from panel unit-root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9(3) (2001) 482-493], is used to investigate the mean-reverting behavior of the current account of 48 African countries during the 1980-2004 periods. The empirical results from numerous panel-based unit root tests, conducted earlier, indicated that the current account of each of these countries is stationary; however, when Breuer et al.'s (2001) Panel SURADF test is conducted, it is found that a unit root exists in the current account of 11 of the countries studied. These results have one extremely important policy implication for the 48 African countries studied: the current account deficit of most is sustainable, and thus signifying that those nations should have no incentive to default on their international debt.

  8. Evaluation of skin test reactivity to environmental allergens in healthy cats and cats with atopic dermatitis.

    Schleifer, Sebastian G; Willemse, Ton

    2003-06-01

    To evaluate skin test reactivity to environmental allergens in healthy cats and in cats with atopic dermatitis (AD). 10 healthy cats and 10 cats with AD. 10 allergens in serial dilutions were injected ID on the lateral aspect of the thorax of sedated cats. Histamine (0.01% solution) and buffer solutions were used as positive and negative controls, respectively. Immediately after the last injection, 10% fluorescein solution was administered IV. Skin test results were evaluated with ultraviolet light after 15 to 30 minutes and at 4 and 6 hours by 2 independent observers. In the control group, skin tests were repeated after 6 weeks. Skin test reactivity and the nature of the immunoglobulin involved were investigated by use of the Prausnitz-Küstner test with untreated and heat-treated cat sera. Intertest and interobserver agreement were high when measurement of the diameter of the fluorescent wheal was used to evaluate skin test responses, compared with assessment of its intensity. In both groups of cats, immediate skin test reactivity was observed as an IgE-mediated reaction, as an IgG-mediated reaction, and as a result of nonspecific mast cell degranulation. There was no correlation between allergen concentration and the type of reaction observed. Skin test reactivity in cats should be evaluated after IV administration of 10% fluorescein solution by means of a Prausnitz-Küstner test to differentiate among IgE-mediated, IgG-mediated, and nonspecific reactions.

  9. Designing, Modeling, Constructing, and Testing a Flat Panel Speaker and Sound Diffuser for a Simulator

    Dillon, Christina

    2013-01-01

    The goal of this project was to design, model, build, and test a flat panel speaker and frame for a spherical dome structure being made into a simulator. The simulator will be a test bed for evaluating an immersive environment for human interfaces. This project focused on the loud speakers and a sound diffuser for the dome. The rest of the team worked on an Ambisonics 3D sound system, video projection system, and multi-direction treadmill to create the most realistic scene possible. The main programs utilized in this project, were Pro-E and COMSOL. Pro-E was used for creating detailed figures for the fabrication of a frame that held a flat panel loud speaker. The loud speaker was made from a thin sheet of Plexiglas and 4 acoustic exciters. COMSOL, a multiphysics finite analysis simulator, was used to model and evaluate all stages of the loud speaker, frame, and sound diffuser. Acoustical testing measurements were utilized to create polar plots from the working prototype which were then compared to the COMSOL simulations to select the optimal design for the dome. The final goal of the project was to install the flat panel loud speaker design in addition to a sound diffuser on to the wall of the dome. After running tests in COMSOL on various speaker configurations, including a warped Plexiglas version, the optimal speaker design included a flat piece of Plexiglas with a rounded frame to match the curvature of the dome. Eight of these loud speakers will be mounted into an inch and a half of high performance acoustic insulation, or Thinsulate, that will cover the inside of the dome. The following technical paper discusses these projects and explains the engineering processes used, knowledge gained, and the projected future goals of this project

  10. Prognostic classification of MDS is improved by the inclusion of FISH panel testing with conventional cytogenetics.

    Kokate, Prajakta; Dalvi, Rupa; Koppaka, Neeraja; Mandava, Swarna

    2017-10-01

    Cytogenetics is a critical independent prognostic factor in myelodysplastic syndromes (MDS). Conventional cytogenetics (CC) and Fluorescence in situ hybridization (FISH) Panel Testing are extensively used for the prognostic stratification of MDS, although the FISH test is not yet a bona fide component of the International Prognostic Scoring System (IPSS). The present study compares the utility of CC and FISH to detect chromosomal anomalies and in prognostic categorization. GTG-Banding and FISH Panel Testing specifically for -5/-5q, -7/-7q, +8 and -20q was performed on whole blood or bone marrow samples from 136 patients with MDS. Chromosomal anomalies were found in 40 cases by CC, including three novel translocations. FISH identified at least one anomaly in 54/136 (39.7%) cases. More than one anomaly was found in 18/54 (33.3%) cases, therefore, overall FISH identified 75 anomalies of which 32 (42.6%) were undetected by CC. FISH provided additional information in cases with CC failure and in cases with a normal karyotype. Further, in ten cases with an abnormal karyotype, FISH could identify additional anomalies, increasing the number of abnormalities per patient. Although CC is the gold standard in the cytogenetic profiling of MDS, FISH has proven to be an asset in identifying additional abnormalities. The number of anomalies per patient can predict the prognosis in MDS and hence, FISH contributed towards prognostic re-categorization. The FISH Panel testing should be used as an adjunct to CC, irrespective of the adequacy of the number of metaphases in CC, as it improves the prognostic classification of MDS. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A new checkerboard panel for testing bacterial markers in periodontal disease.

    Dahlén, G; Leonhardt, A

    2006-02-01

    Various microbiological methods have been used for testing bacterial markers for periodontitis and periodontal disease progression. Most studies have used only a limited number of well recognized bacterial species. The purpose of the present study was to evaluate the association of 13 more recently identified bacterial species in a new panel in comparison with 12 previously more recognized periodontotopathogens ('old panel') using the 'checkerboard' DNA-DNA hybridization method. Fifty individuals were chosen who showed at least one site with a probing pocket depth of 6 mm or more (disease) and bleeding on probing and at least one site with a probing pocket depth of 3 mm and without bleeding on probing (health). One diseased and one healthy site on each individual were sampled with the paperpoint technique and the samples were processed in the checkerboard technique against deoxigenin-labeled whole genomic probes to 25 subgingival species representing 12 well recognized and 13 newly identified periodontitis associated species. Twenty-four (out of 25) species were detected more frequently in the subgingival plaque of diseased than healthy sites both at score 1 (> 10(4)) and score 3 (> 10(5)). A significant difference at the higher score (score 3) was noticed for all species of the old panel except for three (Streptococcus intermedius, Selenomonas noxia, and Eikenella corrodens). Of the species in the new panel only Prevotella tannerae, Filifactor alocis, and Porphyromonas endodontalis showed a statistical significant difference between diseased and healthy sites. It was concluded that P. tannerae, F. alocis, and P. endodontalis should be added to the 12 species used for routine diagnostics of periodontitis-associated bacterial flora.

  12. Documented tuberculin skin testing among infliximab users following a multi-modal risk communication interventions.

    Shatin, Deborah; Rawson, Nigel S B; Curtis, Jeffrey R; Braun, M Miles; Martin, Carolyn K; Moreland, Larry W; Becker, Angela F; Patkar, Nivedita M; Allison, Jeroan J; Saag, Kenneth G

    2006-01-01

    Following its licensure, tuberculosis (TB) was reported as a potential adverse effect of infliximab. Subsequently, the product circular was changed to recommend tuberculin skin testing before patients received infliximab, which was reinforced by several risk communication efforts. The aim of this study was to evaluate patterns and predictors of documented tuberculin skin testing in patients before and after manufacturer, federal, and academic risk communications. Patients administered infliximab were identified from 11 health plans located throughout the United States, and claims data were examined to determine whether the patients had received a tuberculin skin test. Patients were divided into three cohorts depending on the timing of their first infliximab treatment in relation to the risk communication efforts. The overall tuberculin skin testing rate doubled from 15.4% in the first cohort to 30.9% in the last cohort, while the rate of pre-infliximab treatment testing increased from 0 to 27.7% (Chi-squared test for trend, p skin testing rates were significantly higher in women, those with a diagnosis of rheumatoid or psoriatic arthritis, and those with a rheumatologist as prescriber. After multivariable analysis, only rheumatologist remained significantly associated with tuberculin skin testing. Although the tuberculin skin testing rate was relatively low overall, tuberculin skin testing doubled over 30 months of ongoing risk communication efforts and under ascertainment likely occurred. We also found variation in the tuberculin skin testing rate associated with physician specialty. This study demonstrates a significant change in patient care following risk communication efforts. (c) 2005 John Wiley & Sons, Ltd.

  13. Feasibility, Benefits, and Limitations of a Penicillin Allergy Skin Testing Service.

    Narayanan, Prasanna P; Jeffres, Meghan N

    2017-06-01

    To critically examine the feasibility, benefits, and limitations of an inpatient penicillin skin testing service and how pharmacists can be utilized. A PubMed search was performed from July 2016 through September 2016 using the following search terms: penicillin skin testing, penicillin allergy, β-lactam allergy. Additional references were identified from a review of literature citations. All English-language studies assessing the use of penicillin skin testing as well as management and clinical outcomes of patients with a β-lactam allergy were evaluated. The prevalence of people self-identifying as penicillin allergic ranges from 10% to 20% in the United States. Being improperly labeled as penicillin allergic is associated with higher health care costs, worse clinical outcomes, and an increased prevalence of multidrug-resistant infections. Penicillin skin testing can be a tool used to clarify penicillin allergies and has been demonstrated to be a successful addition to antimicrobial stewardship programs in multiple health care settings. Prior to implementing a penicillin skin testing service, institutions will need to perform a feasibility analysis of who will supply labor and accept the financial burden as well as identify if the positive benefits of a penicillin skin testing service overcome the limitations of this diagnostic test. We conclude that institutions with high percentages of patients receiving non-β-lactams because of penicillin allergy labels would likely benefit the most from a penicillin skin testing service.

  14. Immediate hypersensitivity to iodinated contrast media: diagnostic accuracy of skin tests and intravenous provocation test with low dose.

    Sesé, L; Gaouar, H; Autegarden, J-E; Alari, A; Amsler, E; Vial-Dupuy, A; Pecquet, C; Francès, C; Soria, A

    2016-03-01

    The diagnosis of HSR to iodinated contrast media (ICM) is challenging based on clinical history and skin tests. This study evaluates the negative predictive value (NPV) of skin tests and intravenous provocation test (IPT) with low-dose ICM in patients with suspected immediate hypersensitivity reaction (HSR) to ICM. Thirty-seven patients with suspected immediate hypersensitivity reaction to ICM were included retrospectively. Skin tests and a single-blind placebo-controlled intravenous provocation test (IPT) with low-dose iodinated contrast media (ICM) were performed. Skin tests with ICM were positive in five cases (one skin prick test and five intradermal test). Thirty-six patients were challenged successfully by IPT, and only one patient had a positive challenge result, with a grade I reaction by the Ring and Messmer classification. Ten of 23 patients followed up by telephone were re-exposed to a negative tested ICM during radiologic examination; two experienced a grade I immediate reaction. For immediate hypersensitivity reaction to ICM, the NPV for skin tests and IPT with low dose was 80% (95% CI 44-97%). © 2016 John Wiley & Sons Ltd.

  15. A tuberculin skin test survey among Ghanaian school children

    Addo, K.K.; van den Hof, S.; Mensah, G.I.; Hesse, A.; Bonsu, C.; Koram, K.A.; Afutu, F.K.; Bonsu, F.A.

    2010-01-01

    Ghana has not conducted a national tuberculin survey or tuberculosis prevalence survey since the establishment of the National Tuberculosis Control Programme. The primary objective of this study was therefore to determine the prevalence of tuberculin skin sensitivity in Ghanaian school children aged

  16. A tuberculin skin test survey among Ghanaian school children.

    Addo, Kennedy Kwasi; van den Hof, Susan; Mensah, Gloria Ivy; Hesse, Adukwei; Bonsu, Christian; Koram, Kwadwo Ansah; Afutu, Felix Kwami; Bonsu, Frank Adae

    2010-01-26

    Ghana has not conducted a national tuberculin survey or tuberculosis prevalence survey since the establishment of the National Tuberculosis Control Programme. The primary objective of this study was therefore to determine the prevalence of tuberculin skin sensitivity in Ghanaian school children aged 6-10 years in 8 out of 10 regions of Ghana between 2004 and 2006. Tuberculin survey was conducted in 179 primary schools from 21 districts in 8 regions. Schools were purposively selected so as to reflect the proportion of affluent private and free tuition public schools as well as the proportion of small and large schools. Of the 24,778 children registered for the survey, 23,600 (95.2%) were tested of which 21,861 (92.6%) were available for reading. The age distribution showed an increase in numbers of children towards older age: 11% of the children were 6 years and 25%, 10 years. Females were 52.5% and males 47.5%. The proportion of girls was higher in all age groups (range 51.4% to 54.0%, p < 0.001). BCG scar was visible in 89.3% of the children. The percentage of children with a BCG scar differed by district and by age. The percentage of children with a BCG scar decreased with increasing age in all districts, reflecting increasing BCG vaccination coverage in Ghana in the last ten years. The risk of tuberculosis infection was low in the northern savannah zones compared to the southern coastal zones. Using a cut-off of 15 mm, the prevalence of infection ranged from 0.0% to 5.4% and the Annual Risks of Tuberculosis Infection 0.0% to 0.6%. There was an increase in the proportion of infected children after the age of 7 years. Children attending low and middle-class schools had a higher risk of infection than children attending upper-class schools. Tuberculosis infection is still a public health problem in Ghana and to monitor the trend, the survey needs to be repeated at 5 years interval.

  17. Fatigue test of a fiberglass based composite panel. Increasing the lifetime of freight wagon

    Sobek, M.; Baier, A.; Grabowski, Ł.; Majzner, M.

    2016-08-01

    In the XXI century transportation of goods plays a key role in the economy. Due to a good logistics the economy is able to grow fluently. Although land transportation is carried out mainly through trucks for the last several years there has been noted an increase in the percentage share of rail transport in the freight transport. The main goods transported by railways are mineral fuels, mining and quarrying products. They constitute the greater part of 70% of total transported goods. Transportation of material of such high weight, high hardness and with different shapes involves increased and accelerated wear and tear of the cargo space of the wagon. This process is also magnified by substances used to prevent overheating or goods theft. Usually they are in the form of chemical compounds powder, eg. Calcium. A very large impact on the wear of the freight wagons hull is made because of mechanical damage. Their source comes mostly from loading cargo with impetus and using heavy machines during unloading. A large number of cycles of loading and unloading during the working period causes abrasion of body and as a result after several years a wagon car qualifies for a major maintenance. Possibility of application composite panels in the process of renovating the wagons body could reduce the weight of whole train and prolong the service life between mandatory technical inspection. The Paper "Fatigue test of a fiberglass based composite panel. Increasing the lifetime of freight wagon" presents the research process and the results of the endurance test of the composite panel samples fixed to a metal plate. As a fixing method a stainless steel rivet nut and a stainless steel button head socket screws were chosen. Cyclic and multiple load were applied to test samples using a pneumatic cylinder. Such a methodology simulated the forces resulting from loading and unloading of the wagon and movement of the cargo during transport. In the study a dedicated stand equipped with a

  18. Component and prototype panel testing of the mini-dome Fresnel lens photovoltaic concentrator array

    Piszczor, Michael F.; Swartz, Clifford K.; O'Neill, Mark J.

    1990-01-01

    The mini-dome Fresnel lens concentrator array, a high-efficiency, lightweight space photovoltaic array concept, is described. The three critical elements of the array concept are the Fresnel lens concentrator, the prismatic cell power cover, and the photovoltaic cell. Prototype concentrator lenses have been fabricated and tested, with optical efficiencies reaching 90 percent. Work is progressing on the design and fabrication of the panel structure. The impact of recent advances in 30 percent-efficient multijunction photovoltaic cells on array performance is also discussed. Near-term performance goals of 300 w/sq m and 100 w/kg are now feasible.

  19. The solar panels of the spacecraft Stardust are deployed before undergoing lighting test in the PHSF

    1999-01-01

    In the Payload Hazardous Servicing Facility, workers look over the solar panels on the Stardust spacecraft that are deployed for lighting tests. Stardust is scheduled to be launched aboard a Boeing Delta II rocket from Launch Pad 17A, Cape Canaveral Air Station, on Feb. 6, 1999, for a rendezvous with the comet Wild 2 in January 2004. Stardust will use a substance called aerogel to capture comet particles flying off the nucleus of the comet, plus collect interstellar dust for later analysis. The collected samples will return to Earth in a sample return capsule to be jettisoned as it swings by Earth in January 2006.

  20. Skin signs in Ehlers-Danlos syndrome: clinical tests and para-clinical methods

    Remvig, Lars; Duhn, Ph; Ullman, S

    2010-01-01

    Objective: The criteria for Ehlers-Danlos syndrome (EDS) and the hypermobility syndrome (HMS) should be reliable. Examination for general joint hypermobility has high reliability but there is only sparse information on the reliability of skin tests, and no information on the level of normal skin...

  1. Skin signs in Ehlers-Danlos syndrome: clinical tests and para-clinical methods

    Remvig, L; Duhn, Ph; Ullman, S

    2010-01-01

    The criteria for Ehlers-Danlos syndrome (EDS) and the hypermobility syndrome (HMS) should be reliable. Examination for general joint hypermobility has high reliability but there is only sparse information on the reliability of skin tests, and no information on the level of normal skin extensibility...

  2. Comprehensive metabolic panel

    Metabolic panel - comprehensive; Chem-20; SMA20; Sequential multi-channel analysis with computer-20; SMAC20; Metabolic panel 20 ... Chernecky CC, Berger BJ. Comprehensive metabolic panel (CMP) - blood. In: ... Tests and Diagnostic Procedures . 6th ed. St Louis, MO: ...

  3. Pollen food allergy syndrome in Turkey: Clinical characteristics and evaluation of its association with skin test reactivity to pollens.

    Özdemir, Seςil Kepil; Özgüςlü, Selcan

    2017-09-17

    There is limited data regarding pollen food allergy syndrome (PFAS) in Turkey. To investigate the clinical characteristics and possible risk factors of PFAS in Turkey, and to evaluate if there was an association between skin test reactivity to pollens and presence of PFAS. A total of 254 consecutive adult patients with pollen sensitivity were prospectively recruited. Patients were interviewed with a questionnaire including a list of pollen-associated foods. Patients were classified as having PFAS if they reported clear allergic symptoms compatible with PFAS. All participants underwent skin prick tests (SPT) to a panel of common aeroallergens, prick-to-prick tests with culprit fresh foods were performed in patients who gave consent. Self-reported PFAS was observed in 49 patients (19.3%). The most common culprit foods were kiwi, peach, tomato, melon and watermelon. Multiple logistic regression analysis showed that potential risk factors for PFAS were having asthma (OR=2.392, P=0.044) and tree pollen sensitization (OR=2.904, P=0.004). There were no significant differences in the SPT wheal sizes to individual pollen extracts between patients with and without PFAS with a positive SPT result for that pollen extract (P> 0.05). PFAS is frequent in pollen sensitized adults in Turkey. The most commonly implicated foods are kiwi, peach,tomato, melon and watermelon, in our geographical region. SPT wheal sizes to pollen extracts seems to be similar in patients with and without PFAS.

  4. Factors influencing and modifying the decision to pursue genetic testing for skin cancer risk.

    Fogel, Alexander L; Jaju, Prajakta D; Li, Shufeng; Halpern-Felsher, Bonnie; Tang, Jean Y; Sarin, Kavita Y

    2017-05-01

    Across cancers, the decision to pursue genetic testing is influenced more by subjective than objective factors. However, skin cancer, which is more prevalent, visual, and multifactorial than many other malignancies, may offer different motivations for pursuing such testing. The primary objective was to determine factors influencing the decision to receive genetic testing for skin cancer risk. A secondary objective was to assess the impact of priming with health questions on the decision to receive testing. We distributed anonymous online surveys through ResearchMatch.org to assess participant health, demographics, motivations, and interest in pursuing genetic testing for skin cancer risk. Two surveys with identical questions but different question ordering were used to assess the secondary objective. We received 3783 responses (64% response rate), and 85.8% desired testing. Subjective factors, including curiosity, perceptions of skin cancer, and anxiety, were the most statistically significant determinants of the decision to pursue testing (P < .001), followed by history of sun exposure (odds ratio 1.85, P < .01) and history of skin cancer (odds ratio 0.5, P = .01). Age and family history of skin cancer did not influence this decision. Participants increasingly chose testing if first queried about health behaviors (P < .0001). The decision to pursue hypothetical testing may differ from in-clinic decision-making. Self-selected, online participants may differ from the general population. Surveys may be subject to response bias. The decision to pursue genetic testing for skin cancer is primarily determined by subjective factors, such as anxiety and curiosity. Health factors, including skin cancer history, also influenced decision-making. Priming with consideration of objective health factors can increase the desire to pursue testing. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Design, Fabrication, and Testing of Active Skin Antenna with 3D Printing Array Framework

    Jinzhu Zhou

    2017-01-01

    Full Text Available An active skin antenna with structural load-bearing and electromagnetic functions is usually installed in the structural surface of mobile vehicles such as aircrafts, warships, and high-speed train. This paper presents the design, fabrication, and testing of a novel active skin antenna which consists of an encapsulation shell, antenna skin, and RF and beam control circuits. The antenna skin which consists of the facesheet, honeycomb, array framework, and microstrip antenna elements was designed by using Bayesian optimization, in order to improve the design efficiency. An active skin antenna prototype with 32 microstrip antenna elements was fabricated by using a hybrid manufacturing method. In this method, 3D printing technology was applied to fabricate the array framework, and the different layers were bonded to form the final antenna skin by using traditional composite process. Some experimental testing was conducted, and the testing results validate the feasibility the proposed antenna skin structure. The proposed design and fabrication technique is suitable for the development of conformal load-bearing antenna or smart skin antenna installed in the structural surface of aircraft, warships, and armored vehicles.

  6. Nuclear energy consumption, oil consumption and economic growth in G-6 countries: Bootstrap panel causality test

    Chu, Hsiao-Ping; Chang Tsangyao

    2012-01-01

    This study applies bootstrap panel Granger causality to test whether energy consumption promotes economic growth using data from G-6 countries over the period of 1971–2010. Both nuclear and oil consumption data are used in this study. Regarding the nuclear consumption-economic growth nexus, nuclear consumption causes economic growth in Japan, the UK, and the US; economic growth causes nuclear consumption in the US; nuclear consumption and economic growth show no causal relation in Canada, France and Germany. Regarding oil consumption-economic growth nexus, we find that there is one-way causality from economic growth to oil consumption only in the US, and that oil consumption does not Granger cause economic growth in G-6 countries except Germany and Japan. Our results have important policy implications for the G-6 countries within the context of economic development. - Highlights: ► Bootstrap panel Granger causality test whether energy consumption promotes economic growth. ► Data from G-6 countries for both nuclear and oil consumption data are used. ► Results have important policy implications within the context of economic development.

  7. The procurement and testing of the stainless steel in-vessel panels of the Wendelstein 7-X Stellarator

    Peacock, A., E-mail: alan.peacock@ipp.mpg.de [European Commission c/o Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Girlinger, A. [MAN Diesel and Turbo SE D-94469 Deggendorf (Germany); Vorkoeper, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 17491 Greifswald (Germany); Boscary, J.; Greuner, H. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Hurd, F. [European Commission c/o Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Mendelevitch, B.; Pirsch, H.; Stadler, R.; Zangl, G. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany)

    2011-10-15

    320 In-vessel water cooled stainless steel panels, poloidal closure plates and pumping gap panels, covering an area of approximately 100 m{sup 2}, are used in Wendelstein7-X to protect the plasma vessel. The panels are manufactured at Deggendorf, Germany by MAN Diesel and Turbo SE. The panels consist of a laser welded sandwich of stainless steel plates together with a labyrinth of cooling channels and have a complicated geometry to fit the plasma vessel of Wendelstein 7-X. The hydraulic and mechanical stability requirements whilst maintaining the tight tolerances for the shape of the components are very demanding. The panels are designed to operate at up to an average heat load of 100 kW/m{sup 2} and a maximum heat load of 200 kW/m{sup 2} with a water velocity of approximately 2 m s{sup -1}. High heat flux testing of an un-cooled panel at a time averaged load of 200 kW/m{sup 2} for 10 s were successfully performed to support the start up phase of Wendelstein 7-X operation. Extensive testing both during manufacture and after delivery to IPP-Garching demonstrates the suitability of the delivered panels for their purpose.

  8. The procurement and testing of the stainless steel in-vessel panels of the Wendelstein 7-X Stellarator

    Peacock, A.; Girlinger, A.; Vorkoeper, A.; Boscary, J.; Greuner, H.; Hurd, F.; Mendelevitch, B.; Pirsch, H.; Stadler, R.; Zangl, G.

    2011-01-01

    320 In-vessel water cooled stainless steel panels, poloidal closure plates and pumping gap panels, covering an area of approximately 100 m 2 , are used in Wendelstein7-X to protect the plasma vessel. The panels are manufactured at Deggendorf, Germany by MAN Diesel and Turbo SE. The panels consist of a laser welded sandwich of stainless steel plates together with a labyrinth of cooling channels and have a complicated geometry to fit the plasma vessel of Wendelstein 7-X. The hydraulic and mechanical stability requirements whilst maintaining the tight tolerances for the shape of the components are very demanding. The panels are designed to operate at up to an average heat load of 100 kW/m 2 and a maximum heat load of 200 kW/m 2 with a water velocity of approximately 2 m s -1 . High heat flux testing of an un-cooled panel at a time averaged load of 200 kW/m 2 for 10 s were successfully performed to support the start up phase of Wendelstein 7-X operation. Extensive testing both during manufacture and after delivery to IPP-Garching demonstrates the suitability of the delivered panels for their purpose.

  9. A Comparative Study of the Analysis, Numerical Modelling and Experimental Test on a Sandwich Panel with Plane and Profiled Facings

    Raluca Hohan

    2010-01-01

    Full Text Available Sandwich panels are remarkable products because they can be as strong as a solid material but with less weight. The analysis that is required to predict the stresses and deflections in panels with flat or lightly profiled facings is that of conventional beam theory but with the addition of shear deformation. Knowing that the profiled sheets bring an increase of the flexural stiffness, formulas showing the calculus of a panel with flat and profiled facings are established. A comparison between the results of a mathematical calculus, an experimental test and a numerical modelling is provided.

  10. Utilization of multigene panels in hereditary cancer predisposition testing: analysis of more than 2,000 patients

    LaDuca, Holly; Stuenkel, A J; Dolinsky, Jill S.; Keiles, Steven; Tandy, Stephany; Pesaran, Tina; Chen, Elaine; Gau, Chia-Ling; Palmaer, Erika; Shoaepour, Kamelia; Shah, Divya; Speare, Virginia; Gandomi, Stephanie; Chao, Elizabeth

    2014-01-01

    Purpose: The aim of this study was to determine the clinical and molecular characteristics of 2,079 patients who underwent hereditary cancer multigene panel testing. Methods: Panels included comprehensive analysis of 14–22 cancer susceptibility genes (BRCA1 and BRCA2 not included), depending on the panel ordered (BreastNext, OvaNext, ColoNext, or CancerNext). Next-generation sequencing and deletion/duplication analyses were performed for all genes except EPCAM (deletion/duplication analysis o...

  11. Helminths and skewed cytokine profiles increase tuberculin skin test positivity in Warao Amerindians

    Verhagen, L. M.; Hermans, P. W. M.; Warris, A.; de Groot, R.; Maes, M.; Villalba, J. A.; del Nogal, B.; van den Hof, S.; Mughini Gras, L.; van Soolingen, D.; Pinelli, E.; de Waard, J. H.

    2012-01-01

    The immune regulatory mechanisms involved in the acquisition of Mycobacterium tuberculosis infection in children are largely unknown. We investigated the influence of parasitic infections, malnutrition and plasma cytokine profiles on tuberculin skin test (TST) positivity in Warao Amerindians in

  12. Impact of changed legislation on skin tests: the present and future

    Klimek, Ludger; Hoffmann, Hans Jürgen; Kugler, Alexa; Muraro, Antonella; Hellings, Peter W.

    2016-01-01

    To discuss the impact of current European Union regulations on the availability of commercially available skin test allergens in European member states. European Union legislations now define diagnostic allergens to be medicine requiring market authorization of every individual diagnostic allergen

  13. Dual skin tests with Mycobacterium avium sensitin and PPD to detect misdiagnosis of latent tuberculosis infection.

    Larson, E M; O'Donnell, M; Chamblee, S; Horsburgh, C R; Marsh, B J; Moreland, J D; Johnson, L S; von Reyn, C Fordham

    2011-11-01

    A positive tuberculin skin test (TST) may indicate cross-reacting immunity to non-tuberculous mycobacteria (NTM) and not latent tuberculosis infection (LTBI). To assess misclassification of LTBI, as assessed by skin testing with Mycobacterium avium sensitin (MaS), and to determine how this misclassification affects the analysis of risk factors for LTBI. In a population-based survey, participants underwent skin testing with M. tuberculosis purified protein derivative (PPD) and MaS. A PPD-dominant skin test was a reaction that was ≥ 3 mm larger than the MaS reaction; a MaS-dominant skin test was a reaction that was ≥ 3 mm larger than the PPD reaction. Of 447 randomly selected persons, 135 (30%) had a positive PPD test. Of these, 21 (16%) were MaS- dominant, and were therefore attributable to NTM and misclassified as LTBI. PPD reactions of 5-14 mm were more likely to be misclassified than those ≥ 15 mm (OR = 5.0, 95%CI 1.9-13.2). Adjusting for misclassification had only a small impact on the analysis of risk factors for LTBI. A substantial number of individuals who are diagnosed with LTBI are actually sensitized to NTM. Using dual skin testing would reduce misdiagnosis and prevent unnecessary treatment.

  14. Testing the Grossman model of medical spending determinants with macroeconomic panel data.

    Hartwig, Jochen; Sturm, Jan-Egbert

    2018-02-16

    Michael Grossman's human capital model of the demand for health has been argued to be one of the major achievements in theoretical health economics. Attempts to test this model empirically have been sparse, however, and with mixed results. These attempts so far relied on using-mostly cross-sectional-micro data from household surveys. For the first time in the literature, we bring in macroeconomic panel data for 29 OECD countries over the period 1970-2010 to test the model. To check the robustness of the results for the determinants of medical spending identified by the model, we include additional covariates in an extreme bounds analysis (EBA) framework. The preferred model specifications (including the robust covariates) do not lend much empirical support to the Grossman model. This is in line with the mixed results of earlier studies.

  15. CAT SCRATCH DISEASE: RESULTS OF COMPLEMENT-FIXATION AND SKIN TESTS

    Serologic and skin-testing data on a group of patients having cat scratch disease are presented to demonstrate a possible relationship to the psitt...indicate that the incidence of positive serologic reactions with the psitt-LGV group antigen is consistently higher in patients with cat scratch disease...patients, 2 of 5 did not respond with positive skin reactions when tested with cat scratch antigen, and at least 2 of the remaining 3 responded in a manner difficult to interpret.

  16. [Practice patterns in Mexican allergologists about skin tests with allergens during 2005-2006].

    Larenas Linnemann, Désirée; Fogelbach, Guillermo Arturo Guidos; Cruz, Alfredo Arias

    2008-01-01

    Immunotherapy has been practiced since over a hundred years. The exact composition of the immunotherapy concentrate, with which the patient is treated, depends partly on the results of the skin prick tests applied to the allergic patient. As such, the effectiveness of the immunotherapy depends heavily on the quality of the skin prick test. The detailed recommendations for the realization of the skin prick tests have evolved and changed over the years, leading to multiple variations in its application in Mexico. We tried to get a picture of the daily practice patterns of the members of CMICA and CoMPedIA concerning the application of skin prick tests. Aquestionnaire was sent in various occasions to all members of the Colegio Mexicano de Inmunologia Clinica y Alergia (CMICA) and of the Colegio Mexicano de Pediatras, Especialistas en Inmunologia y Alergia (CoMPedIA). The results are presented descriptively and by calculation of the frequency/percentages of intervals of replies, in the case of numerical responses. A response rate of 61 (17%) was obtained of the College members, showing consistency in some replies but a wide variation in others, for example in the time certain medication has to be suspended before the execution of the skin prick test. Comparing the replies obtained with recent recommendations in international publications, some discrepancy can be detected. In some aspects of the survey there is coincidence of the skin test practices among the participants; however, in other items there is an important variation.

  17. Skin age testing criteria: characterization of human skin structures by 500 MHz MRI multiple contrast and image processing

    Sharma, Rakesh

    2010-01-01

    Ex vivo magnetic resonance microimaging (MRM) image characteristics are reported in human skin samples in different age groups. Human excised skin samples were imaged using a custom coil placed inside a 500 MHz NMR imager for high-resolution microimaging. Skin MRI images were processed for characterization of different skin structures. Contiguous cross-sectional T1-weighted 3D spin echo MRI, T2-weighted 3D spin echo MRI and proton density images were compared with skin histopathology and NMR peaks. In all skin specimens, epidermis and dermis thickening and hair follicle size were measured using MRM. Optimized parameters TE and TR and multicontrast enhancement generated better MRI visibility of different skin components. Within high MR signal regions near to the custom coil, MRI images with short echo time were comparable with digitized histological sections for skin structures of the epidermis, dermis and hair follicles in 6 (67%) of the nine specimens. Skin % tissue composition, measurement of the epidermis, dermis, sebaceous gland and hair follicle size, and skin NMR peaks were signatures of skin type. The image processing determined the dimensionality of skin tissue components and skin typing. The ex vivo MRI images and histopathology of the skin may be used to measure the skin structure and skin NMR peaks with image processing may be a tool for determining skin typing and skin composition.

  18. Skin age testing criteria: characterization of human skin structures by 500 MHz MRI multiple contrast and image processing

    Sharma, Rakesh, E-mail: rs05h@fsu.ed [Departments of Chemical Engineering and Biomedical Engineering, FAMU-FSU College of Engineering, Tallahassee, FL 32310 (United States)

    2010-07-21

    Ex vivo magnetic resonance microimaging (MRM) image characteristics are reported in human skin samples in different age groups. Human excised skin samples were imaged using a custom coil placed inside a 500 MHz NMR imager for high-resolution microimaging. Skin MRI images were processed for characterization of different skin structures. Contiguous cross-sectional T1-weighted 3D spin echo MRI, T2-weighted 3D spin echo MRI and proton density images were compared with skin histopathology and NMR peaks. In all skin specimens, epidermis and dermis thickening and hair follicle size were measured using MRM. Optimized parameters TE and TR and multicontrast enhancement generated better MRI visibility of different skin components. Within high MR signal regions near to the custom coil, MRI images with short echo time were comparable with digitized histological sections for skin structures of the epidermis, dermis and hair follicles in 6 (67%) of the nine specimens. Skin % tissue composition, measurement of the epidermis, dermis, sebaceous gland and hair follicle size, and skin NMR peaks were signatures of skin type. The image processing determined the dimensionality of skin tissue components and skin typing. The ex vivo MRI images and histopathology of the skin may be used to measure the skin structure and skin NMR peaks with image processing may be a tool for determining skin typing and skin composition.

  19. Utility of minor determinants for skin testing in inpatient penicillin allergy evaluation.

    Geng, Bob; Eastman, Jacqueline J; Mori, Karen; Braskett, Melinda; Riedl, Marc A

    2017-09-01

    Most patients with a history of penicillin allergy can tolerate penicillin. Skin testing can identify tolerant patients, but not all known allergenic determinants are commercially available. Protocols exist that use only available reagents, but the sensitivity and safety of these protocols, particularly for hospitalized patients, are controversial. To determine the number of hospitalized patients referred for penicillin skin testing who showed unique positivity to the minor determinants penicilloate and penilloate. A retrospective chart review was conducted of all inpatients who underwent penicillin skin testing at 1 institution. Patients were referred by their treating physician. All patients underwent skin prick testing to benzylpenicilloyl polylysine (major determinant), penicillin G, penicilloate, penilloate (minor determinants), amoxicillin, and positive and negative controls. If the result was negative, then intradermal testing was done with the same penicillin determinants and the negative control. A 4-mm wheal with flare was considered a positive reaction. Inpatient penicillin skin testing was done in 528 subjects. Any positive test reaction was found in 107 subjects (20%). Three subjects (3%) reacted to penilloate only, 25 (23%) reacted to penicilloate only, 2 (2%) reacted to penicillin G only, and 8 (8%) reacted to amoxicillin only. Sixty-eight subjects (64%) reacted to a compound other than the major determinant. This study found a high rate of exclusively positive skin test reactions to the minor determinants penicilloate and penilloate. Because patients with positive test reactions are at increased risk of reaction to drug challenge, these data support the use of these reagents for penicillin skin testing in hospitalized patients. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  20. Electrostatic Discharge Testing of Carbon Composite Solar Array Panels for Use in the Jovian Environment

    Green, Nelson W.; Dawson, Stephen F.

    2015-01-01

    NASA is currently considering a mission to investigate the moons of Jupiter. When designing a spacecraft for this type of mission, there are a number of engineering challenges, especially if the mission chooses to utilize solar arrays to provide the spacecraft power. In order for solar arrays to be feasible for the mission, their total mass needed to fit within the total budget for the mission, which strongly suggested the use of carbon composite facesheets on an aluminum core for the panel structure. While these composite structures are a good functional substitution for the metallic materials they replace, they present unique challenges when interacting with the harsh Jovian space environment. As a composite material, they are composed of more than one material and can show different base properties depending in differing conditions. Looking at the electrical properties, in an Earth-based environment the carbon component of the composite dominates the response of the material to external stimulus. Under these conditions, the structures strongly resembles a conductor. In the Jovian environment, with temperatures reaching 50K and under the bombardment from energetic electrons, the non-conducting pre-preg binding materials may come to the forefront and change the perceived response. Before selecting solar arrays as the baseline power source for a mission to Jupiter, the response of the carbon composites to energetic electrons while held at cryogenic temperatures needed to be determined. A series of tests were devised to exam the response of a sample solar array panel composed of an M55J carbon weave layup with an RS-3 pre-preg binder. Test coupons were fabricated and exposed to electrons ranging from 10 keV to 100 keV, at 1 nA/cm2, while being held at cryogenic temperatures. While under electron bombardment, electrical discharges were observed and recorded with the majority of discharges occurring with electron energies of 25 keV. A decrease in temperature to liquid

  1. Fabrication and Testing of Carbon Fiber, Graphite-Epoxy Panels for Submillimeter Telescope Use

    Rieger, H.; Helwig, G.; Parks, R. E.; Ulich, B. L.

    1983-12-01

    An experimental carbon-fiber, graphite-epoxy, aluminum Flexcore sandwich panel roughly 1-m square was made by Dornier System, Friedrichshafen, West Germany. The panel was a pre-prototype of the panels to be used in the dish of the 10-m diameter Sub-Millimeter Telescope, a joint project of the Max-Planck-Institute fur Radioastronomie, Bonn, West Germany, and Steward Observatory, the University of Arizona in Tucson. This paper outlines the fabrication process for the panel and indicates the surface accuracy of the panel replication process. To predict the behavior of the panel under various environmental loads, the panel was modeled structurally using anisotropic elements for the core material. Results of this analysis along with experimental verification of these predictions are also given.

  2. Panel-Based Clinical Genetic Testing in 85 Children with Inherited Retinal Disease.

    Taylor, Rachel L; Parry, Neil R A; Barton, Stephanie J; Campbell, Christopher; Delaney, Claire M; Ellingford, Jamie M; Hall, Georgina; Hardcastle, Claire; Morarji, Jiten; Nichol, Elisabeth J; Williams, Lindsi C; Douzgou, Sofia; Clayton-Smith, Jill; Ramsden, Simon C; Sharma, Vinod; Biswas, Susmito; Lloyd, I Chris; Ashworth, Jane L; Black, Graeme C; Sergouniotis, Panagiotis I

    2017-07-01

    To assess the clinical usefulness of genetic testing in a pediatric population with inherited retinal disease (IRD). Single-center retrospective case series. Eighty-five unrelated children with a diagnosis of isolated or syndromic IRD who were referred for clinical genetic testing between January 2014 and July 2016. Participants underwent a detailed ophthalmic examination, accompanied by electrodiagnostic testing (EDT) and dysmorphologic assessment where appropriate. Ocular and extraocular features were recorded using Human Phenotype Ontology terms. Subsequently, multigene panel testing (105 or 177 IRD-associated genes) was performed in an accredited diagnostic laboratory, followed by clinical variant interpretation. Diagnostic yield and clinical usefulness of genetic testing. Overall, 78.8% of patients (n = 67) received a probable molecular diagnosis; 7.5% (n = 5) of these had autosomal dominant disease, 25.4% (n = 17) had X-linked disease, and 67.2% (n = 45) had autosomal recessive disease. In a further 5.9% of patients (n = 5), a single heterozygous ABCA4 variant was identified; all these participants had a spectrum of clinical features consistent with ABCA4 retinopathy. Most participants (84.7%; n = 72) had undergone EDT and 81.9% (n = 59) of these patients received a probable molecular diagnosis. The genes most frequently mutated in the present cohort were CACNA1F and ABCA4, accounting for 14.9% (n = 10) and 11.9% (n = 8) of diagnoses respectively. Notably, in many cases, genetic testing helped to distinguish stationary from progressive IRD subtypes and to establish a precise diagnosis in a timely fashion. Multigene panel testing pointed to a molecular diagnosis in 84.7% of children with IRD. The diagnostic yield in the study population was significantly higher compared with that in previously reported unselected IRD cohorts. Approaches similar to the one described herein are expected to become a standard component of care in pediatric ophthalmology

  3. Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.

    Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin

    2015-02-01

    The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.

  4. [Hypersensitivity to platinum salts and taxanes: The value of skin tests and tolerance induction procedures].

    Brault, F; Waton, J; Poreaux, C; Schmutz, J-L; Barbaud, A

    2017-11-01

    The rate of hypersensitivity reactions to platinum salts (PS) and taxanes (TX) is on the increase. The aim of our study was to show the value of skin testing and efficacy of rapid drug desensitization. This was a retrospective study conducted between January 2007 and February 2016 in patients consulting for immediate or delayed hypersensitivity to PS and TX. Skin prick tests (pT) and intradermal reaction tests (IDR) were performed according to the ENDA/EAACI recommendations. We used a 12-step desensitization protocol for rapid drug desensitization. Among the 99 patients included (30 men, 69 women, age 60.4) PS were suspected in 86 cases and taxanes in 13 cases. Skin tests were positive in 25 patients (7 pT, 18 IDR), 23 for platinum salts and 2 for taxanes. Rapid drug desensitization was proposed in 50 patients and performed in 33 (30 PS and 3 TX), proved effective in 29 patients, with protocol adaptation being necessary in 7 cases, and was ineffective in 4 patients. The skin tests for the latter 4 patients were positive. Seventy-five percent of patients with positive skin tests to oxaliplatin presented hypersensitivity reactions during desensitization, i.e. twice as many as patients having negative skin tests. Two percent of patient for PS and 7% for TX had cross reactivity. This French study confirms the efficacy of the 12-step protocol that allows patients to receive chemotherapy after hypersensitivity reaction. Skin test permits the detection of cross-reactions but their practice must be considered based on the patient's history. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Use of recombinant purified protein derivative (PPD) antigens as specific skin test for tuberculosis.

    Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan

    2012-11-01

    Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB.

  6. Evaluation of seven rapid tests for syphilis available in Brazil using defibrinated plasma panels.

    Bazzo, Maria Luiza; da Motta, Leonardo Rapone; Rudolf-Oliveira, Renata Cristina Messores; Bigolin, Alisson; Golfetto, Lisléia; Mesquita, Fábio; Benzaken, Adele Schwartz; Gaspar, Pamela Cristina; Pires, Ana Flavia Nacif P Coelho; Ferreira Júnior, Orlando da Costa; Franchini, Miriam

    2017-12-01

    In 2012, the WHO estimated that 6 million new cases of syphilis per year would occur worldwide, including 937 000 in Brazil. Early diagnosis and treatment of syphilis are essential to reduce morbidity and prevent transmission. The availability of rapid tests (RTs) for this diagnosis means that testing can be performed more quickly, as a point-of-care test, even in non-laboratory environments and requires only simple technical training to antibodies detection. The objective of this study was to evaluate the performance and operational aspects of seven commercially available RTs for syphilis in Brazil. Seven rapid treponemal tests were evaluated for sensitivity, specificity, accuracy and Kappa value, according to a panel composed of 493 members. The operational performance of the assay was also determined for these tests. The seven RTs showed sensitivity ranging from 94.5% to 100% when compared with the reference tests and specificity of between 91.5% and 100%. All the RTs evaluated presented good operational performance, and only one failed to present the minimum specificity as defined by Brazil's Ministry of Health. All the tests presented good operational performance, and the professionals who performed them considered them to be easy to use and interpret. This evaluation is important for making informed choices of tests to be used in the Brazilian Unified Health System. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Integrating non-animal test information into an adaptive testing strategy - skin sensitization proof of concept case.

    Jaworska, Joanna; Harol, Artsiom; Kern, Petra S; Gerberick, G Frank

    2011-01-01

    There is an urgent need to develop data integration and testing strategy frameworks allowing interpretation of results from animal alternative test batteries. To this end, we developed a Bayesian Network Integrated Testing Strategy (BN ITS) with the goal to estimate skin sensitization hazard as a test case of previously developed concepts (Jaworska et al., 2010). The BN ITS combines in silico, in chemico, and in vitro data related to skin penetration, peptide reactivity, and dendritic cell activation, and guides testing strategy by Value of Information (VoI). The approach offers novel insights into testing strategies: there is no one best testing strategy, but the optimal sequence of tests depends on information at hand, and is chemical-specific. Thus, a single generic set of tests as a replacement strategy is unlikely to be most effective. BN ITS offers the possibility of evaluating the impact of generating additional data on the target information uncertainty reduction before testing is commenced.

  8. Surprisingly high specificity of the PPD skin test for M. tuberculosis infection from recent exposure in The Gambia.

    Hill, Philip C; Brookes, Roger H; Fox, Annette; Jackson-Sillah, Dolly; Lugos, Moses D; Jeffries, David J; Donkor, Simon A; Adegbola, Richard A; McAdam, Keith P W J

    2006-12-20

    Options for intervention against Mycobacterium tuberculosis infection are limited by the diagnostic tools available. The Purified Protein Derivative (PPD) skin test is thought to be non-specific, especially in tropical settings. We compared the PPD skin test with an ELISPOT test in The Gambia. Household contacts over six months of age of sputum smear positive TB cases and community controls were recruited. They underwent a PPD skin test and an ELISPOT test for the T cell response to PPD and ESAT-6/CFP10 antigens. Responsiveness to M. tuberculosis exposure was analysed according to sleeping proximity to an index case using logistic regression. 615 household contacts and 105 community controls were recruited. All three tests assessed increased significantly in positivity with increasing M. tuberculosis exposure, the PPD skin test most dramatically (OR 15.7; 95% CI 6.6-35.3). While the PPD skin test positivity continued to trend downwards in the community with increasing distance from a known case (61.9% to 14.3%), the PPD and ESAT-6/CFP-10 ELISPOT positivity did not. The PPD skin test was more in agreement with ESAT-6/CFP-10 ELISPOT (75%, p = 0.01) than the PPD ELISPOT (53%, pPPD skin test positive increased (pPPD skin test negative decreased (pPPD skin test has surprisingly high specificity for M. tuberculosis infection from recent exposure in The Gambia. In this setting, anti-tuberculous prophylaxis in PPD skin test positive individuals should be revisited.

  9. The use of ex vivo human skin tissue for genotoxicity testing

    Reus, Astrid A.; Usta, Mustafa; Krul, Cyrille A.M.

    2012-01-01

    As a result of the chemical legislation concerning the registration, evaluation, authorization and restriction of chemicals (REACH), and the Seventh Amendment to the Cosmetics Directive, which prohibits animal testing in Europe for cosmetics, alternative methods for safety evaluation of chemicals are urgently needed. Current in vitro genotoxicity assays are not sufficiently predictive for the in vivo situation, resulting in an unacceptably high number of misleading positives. For many chemicals and ingredients of personal care products the skin is the first site of contact, but there are no in vitro genotoxicity assays available in the skin for additional evaluation of positive or equivocal responses observed in regulatory in vitro genotoxicity assays. In the present study ex vivo human skin tissue obtained from surgery was used for genotoxicity evaluation of chemicals by using the comet assay. Fresh ex vivo human skin tissue was cultured in an air–liquid interface and topically exposed to 20 chemicals, including true positive, misleading positive and true negative genotoxins. Based on the results obtained in the present study, the sensitivity, specificity and accuracy of the ex vivo skin comet assay to predict in vivo genotoxicity were 89%, 90% and 89%, respectively. Donor and experimental variability were mainly reflected in the magnitude of the response and not the difference between the presence and absence of a genotoxic response. The present study indicates that human skin obtained from surgery is a promising and robust model for safety evaluation of chemicals that are in direct contact with the skin. -- Highlights: ► We use human skin obtained from surgery for genotoxicity evaluation of chemicals. ► We use the comet assay as parameter for genotoxicity in ex vivo human skin. ► Sensitivity, specificity and accuracy to predict in vivo genotoxins are determined. ► Sensitivity, specificity and accuracy are 89%, 90% and 90%, respectively. ► The method

  10. The use of ex vivo human skin tissue for genotoxicity testing

    Reus, Astrid A.; Usta, Mustafa [TNO Triskelion BV, Utrechtseweg 48, 3704 HE, Zeist (Netherlands); Krul, Cyrille A.M., E-mail: cyrille.krul@tno.nl [TNO, Utrechtseweg 48, 3704 HE Zeist (Netherlands)

    2012-06-01

    As a result of the chemical legislation concerning the registration, evaluation, authorization and restriction of chemicals (REACH), and the Seventh Amendment to the Cosmetics Directive, which prohibits animal testing in Europe for cosmetics, alternative methods for safety evaluation of chemicals are urgently needed. Current in vitro genotoxicity assays are not sufficiently predictive for the in vivo situation, resulting in an unacceptably high number of misleading positives. For many chemicals and ingredients of personal care products the skin is the first site of contact, but there are no in vitro genotoxicity assays available in the skin for additional evaluation of positive or equivocal responses observed in regulatory in vitro genotoxicity assays. In the present study ex vivo human skin tissue obtained from surgery was used for genotoxicity evaluation of chemicals by using the comet assay. Fresh ex vivo human skin tissue was cultured in an air–liquid interface and topically exposed to 20 chemicals, including true positive, misleading positive and true negative genotoxins. Based on the results obtained in the present study, the sensitivity, specificity and accuracy of the ex vivo skin comet assay to predict in vivo genotoxicity were 89%, 90% and 89%, respectively. Donor and experimental variability were mainly reflected in the magnitude of the response and not the difference between the presence and absence of a genotoxic response. The present study indicates that human skin obtained from surgery is a promising and robust model for safety evaluation of chemicals that are in direct contact with the skin. -- Highlights: ► We use human skin obtained from surgery for genotoxicity evaluation of chemicals. ► We use the comet assay as parameter for genotoxicity in ex vivo human skin. ► Sensitivity, specificity and accuracy to predict in vivo genotoxins are determined. ► Sensitivity, specificity and accuracy are 89%, 90% and 90%, respectively. ► The method

  11. Development, validation and testing of a skin sampling method for assessment of metal exposure.

    Erfani, Behnaz; Midander, Klara; Lidén, Carola; Julander, Anneli

    2017-07-01

    Nickel, cobalt and chromium are frequent skin sensitizers. Skin exposure results in eczema in sensitized individuals, the risk being related to the skin dose. To develop a self-sampling method for quantification of skin exposure to metals, to validate the method, and to assess its feasibility. Defined metal doses (0.01-5 µg) were applied to the fingers of 5 participants. Skin areas (2 cm 2 ) were sampled with 1% HNO 3 , either as 0.1 ml on a swab, or as 0.5 ml on a wipe. Furthermore, 17 participants performed self-sampling by swab after 2 h of leisure activity. Samples were extracted in 1% HNO 3 and analysed by inductively coupled plasma mass spectrometry. The sampling efficiency by swab was 46%, as compared with 93% for acid wipe sampling, for all tested doses. Most metal from the skin dose was detected in the first swab (33-43%). Despite lower sampling efficiency by swab, skin doses of metals following 2 h of leisure activity without hand washing were quantified in all participants, and ranged from 0.0016 to 0.15 µg/cm 2 , from 0.00014 to -0.0020 µg/cm 2 and from 0.00048 to -0.027 µg/cm 2 for nickel, cobalt, and chromium, respectively. The results indicate a future potential of skin sampling by swab to detect and monitor metals on skin by self-sampling. This will contribute to better knowledge of metal skin exposure among dermatitis patients, workers, and the general population. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. A research program to reduce interior noise in general aviation airplanes: Investigation of the characteristics of an acoustic panel test facility

    Grosveld, F.; Vanaken, J.

    1978-01-01

    Sound pressure levels in the test facility were studied that are caused by varying: (1) microphone positions; (2) equalizer setting; and (3) panel clamping forces. Measurements were done by using a Beranek tube or this Beranek tube in combinations with an extension tube and a special test section. In all configurations tests were executed with and without a test panel installed. The influence of the speaker back panel and the back panel of the Beranek tube on the sound pressure levels inside the test tube were also investigated. It is shown that the definition of noise reduction is more useful in relation to this test facility than transmission loss.

  13. [Assessment of hypersensitivity to honey-bee venom in beekeepers by skin tests].

    Becerril-Ángeles, Martín; Núñez-Velázquez, Marco; Marín-Martínez, Javier

    2013-01-01

    Beekeepers are exposed to frequent honey-bee stings, and have the risk to develop hypersensitivity to bee venom, but long-term exposure can induce immune tolerance in them. Up to 30% of beekeepers show positive skin tests with honey-bee venom. The prevalence of systemic reactions to bee stings in beekeepers is from 14% to 42%. To know the prevalence of hypersensitivity to honeybee venom in Mexican beekeepers and non-beekeepers by the use of skin tests. A group of 139 beekeepers and a group of 60 non-beekeeper volunteers had a history and physical related to age, sex, family and personal atopic history and time of exposure to bee stings. Both groups received intradermal skin tests with honey-bee venom, 0.1 mcg/mL and 1 mcg/mL, and histamine sulphate 0.1 mg/mL and Evans solution as controls. The skin tests results of both groups were compared by chi-squared test. Of the group of beekeepers, 116 were men (83%) and 23 women, average age was 39.3 years, had atopic family history 28% and personal atopy 13%, average time of exposure to bee stings was 10.9 years, skin tests with honey-bee venom were positive in 16.5% and 11% at 1 mcg/mL and 0.1 mcg/mL, respectively. In the non-beekeepers group venom skin tests were positive in 13.3% and 6.7% at 1 mcg/mL and 0.1 mcg/mL. We did not find significant differences between the two venom concentrations tested in both groups, neither in the number of positive skin tests between the two groups. We found hypersensivity to honey-bee venom slightly higher in the beekeepers than in the group apparently not exposed. Both honey-bee venom concentrations used did not show difference in the results of the skin tests. The similarity of skin tests positivity between both groups could be explained by immune tolerance due to continued exposure of beekeepers.

  14. Optical coherence tomography applied to tests of skin care products in humans--a case study.

    Vasquez-Pinto, L M C; Maldonado, E P; Raele, M P; Amaral, M M; de Freitas, A Z

    2015-02-01

    When evaluating skin care products for human skin, quantitative test methods need to be simple, precise and reliable. Optical coherence tomography (OCT), provides high-resolution sectional images of translucent materials to a depth of a few millimeters, a technique usually applied to medical measurements in ophthalmology and dermatology. This study aimed to demonstrate the application of OCT as the main technique for monitoring changes in skin topography during tests of a wrinkle-reduction product in humans. We used a commercial OCT apparatus to perform clinical examinations of skin roughness in treated and non-treated sites in the periorbital region of thirty human voluntaries who were using an anti-aging product commercially available: Natura Chronos® Flavonóides de Passiflora 45+ FPS15, from Natura Cosméticos, Brazil. Measurements were performed days 0, 7, 14 and 28 of treatment. Equipment and software allowed real-time recording of skin roughness parameters and wrinkle depths. The OCT measurements have allowed the monitoring of changes in skin roughness, which have shown reduction in treated sites around 10%. The obtained depth distributions also indicate reduction in the occurrence of wrinkles deeper than 170 μm. The verified results are consistent with those typically obtained after successful treatment with modern anti-aging products. By using the OCT technique, it was possible to quantify changes in skin roughness and in the distribution of depths of skin wrinkles, with adequate sensitivity. OCT imaging allows the direct visualization of the skin topography with resolution of micrometers, a reliable and interactive tool for clinical use. Therefore, for the first time, we demonstrated the use of OCT technique to verify the efficacy of cosmetic products in real time. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. The Relationship between Financial Freedom, Financial Depth and Mutual Funds: Panel Bounds Testing Approach

    Gönül YÜCE

    2013-03-01

    Full Text Available The purpose of this study is to investigate the nexus between mutual fund assets, financial freedom, and financial depth in 54 countries from 2000 to 2011 by employing panel ARDL bounds testing approach. To examine this linkage, we use the two-step procedure from ARDL bounds testing model: In first step, we explore the long-term relationship between the variables by using ARDL test of cointegration. Secondly, we employ a dynamic error correction model to explore the short-term relationship between the variables. All results suggest that there is a positive and statistically significant evidence between central bank independence, financial freedom, and economic growth in both long and short-term. Besides, long-term empirical results refer that current period central bank independence and financial freedom are the important factors for determining the national output level. In addition, the results of the short-term dynamics are parallel with the long-term estimation results. Furthermore, because the error correction term is found negative and statistically significant, it can be said that the variables converge to equilibrium quickly, and short-term imbalances will be overcomed in the long-term.

  16. Testing Environmental Kuznets Curve in the Selected Transition Economies with Panel Smooth Transition Regression Analysis

    Mahmut Zortuk

    2016-08-01

    Full Text Available The Environmental Kuznets Curve (EKC introduces an inverted U-shaped relationship between environmental pollution and economic development. The inverted U-shaped curve is seen as complete pattern for developed economies. However, our study tests the EKC for developing transition economies of European Union, therefore, our results could make a significant contribution to the literature. In this paper, the relationship between carbon dioxide (CO2 emissions, gross domestic product (GDP, energy use and urban population is investigated in the Transition Economies (Bulgaria, Croatia, Czech Republic, Estonia, Hungary, Latvia, Lithuania, Poland, Romania, Slovakia and Slovenia. Environmental Kuznets Curve is tested by panel smooth transition regression for these economies for 1993 – 2010 periods. As a result of study, the null hypothesis of linearity was rejected and no-remaining nonlinearity test showed that there is a smooth transition exists between two regimes (below $5176 GDP per capita is first one and above $5176 GDP per capita is second one in the related period for these economies.

  17. Sensitivity and specificity of skin tests in the diagnosis of clarithromycin allergy.

    Mori, Francesca; Barni, Simona; Pucci, Neri; Rossi, Elisabetta; Azzari, Chiara; de Martino, Maurizio; Novembre, Elio

    2010-05-01

    Clarithromycin is one of the most frequently prescribed oral macrolidic antibiotics in the pediatric population. Suspected adverse reactions to clarithromycin have been frequently described by parents of children examined in pediatric allergy units, but there is a lack of reliable methods available in detecting the presence of specific IgE antibodies. To investigate the prevalence of a clarithromycin allergy in children seen in a pediatric allergy unit using standardized skin tests and oral provocation tests (OPTs). Sixty-four children were referred with a history of a clarithromycin-associated adverse drug reaction. All these children underwent skin tests and OPTs. The nonirritating intradermal skin test concentration for clarithromycin was determined in a control group of 18 children who had tolerated clarithromycin in the previous month. The threshold nonirritating intradermal concentration was established at the 10:2 dilution (0.5 mg/mL). Nine of the 64 children had an immediately positive intradermal response to the 10:2 dilution and only 1 child to the 10:3 dilution (0.05 mg/mL). None had positive skin prick test results or delayed skin responses to intradermal tests. Four of 64 children (6%) with previously described adverse reactions due to clarithromycin intake had a positive OPT reaction. When we correlated the intradermal skin test results to the OPT results, intradermal test sensitivity and specificity were 75% and 90%, respectively. Intradermal tests seem to be useful in allergologic workup in children with suspected clarithromycin hypersensitivity and may help reduce the need for OPTs.

  18. QSAR models of human data can enrich or replace LLNA testing for human skin sensitization

    Alves, Vinicius M.; Capuzzi, Stephen J.; Muratov, Eugene; Braga, Rodolpho C.; Thornton, Thomas; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2016-01-01

    Skin sensitization is a major environmental and occupational health hazard. Although many chemicals have been evaluated in humans, there have been no efforts to model these data to date. We have compiled, curated, analyzed, and compared the available human and LLNA data. Using these data, we have developed reliable computational models and applied them for virtual screening of chemical libraries to identify putative skin sensitizers. The overall concordance between murine LLNA and human skin sensitization responses for a set of 135 unique chemicals was low (R = 28-43%), although several chemical classes had high concordance. We have succeeded to develop predictive QSAR models of all available human data with the external correct classification rate of 71%. A consensus model integrating concordant QSAR predictions and LLNA results afforded a higher CCR of 82% but at the expense of the reduced external dataset coverage (52%). We used the developed QSAR models for virtual screening of CosIng database and identified 1061 putative skin sensitizers; for seventeen of these compounds, we found published evidence of their skin sensitization effects. Models reported herein provide more accurate alternative to LLNA testing for human skin sensitization assessment across diverse chemical data. In addition, they can also be used to guide the structural optimization of toxic compounds to reduce their skin sensitization potential. PMID:28630595

  19. Use of genotoxicity information in the development of integrated testing strategies (ITS) for skin sensitization.

    Mekenyan, Ovanes; Patlewicz, Grace; Dimitrova, Gergana; Kuseva, Chanita; Todorov, Milen; Stoeva, Stoyanka; Kotov, Stefan; Donner, E Maria

    2010-10-18

    Skin sensitization is an end point of concern for various legislation in the EU, including the seventh Amendment to the Cosmetics Directive and Registration Evaluation, Authorisation and Restriction of Chemicals (REACH). Since animal testing is a last resort for REACH or banned (from 2013 onward) for the Cosmetics Directive, the use of intelligent/integrated testing strategies (ITS) as an efficient means of gathering necessary information from alternative sources (e.g., in vitro, (Q)SARs, etc.) is gaining widespread interest. Previous studies have explored correlations between mutagenicity data and skin sensitization data as a means of exploiting information from surrogate end points. The work here compares the underlying chemical mechanisms for mutagenicity and skin sensitization in an effort to evaluate the role mutagenicity information can play as a predictor of skin sensitization potential. The Tissue Metabolism Simulator (TIMES) hybrid expert system was used to compare chemical mechanisms of both end points since it houses a comprehensive set of established structure-activity relationships for both skin sensitization and mutagenicity. The evaluation demonstrated that there is a great deal of overlap between skin sensitization and mutagenicity structural alerts and their underlying chemical mechanisms. The similarities and differences in chemical mechanisms are discussed in light of available experimental data. A number of new alerts for mutagenicity were also postulated for inclusion into TIMES. The results presented show that mutagenicity information can provide useful insights on skin sensitization potential as part of an ITS and should be considered prior to any in vivo skin sensitization testing being initiated.

  20. Microbiological specifications and testing methods for irradiated food. Report of a panel of experts

    1970-01-01

    In recent years there has been increased interest in the development of food items processed by means of ionizing radiation, wherever that form of preservation might show advantage over other methods. If this method becomes successful, the various items will be commercially exploited; it would then be convenient to have similar legislation in many countries of the world to control this type of processing and to facilitate international trade. To gather information and suggestions in order to devise legislation on irradiated food, a Joint FAO/IAEA/ WHO Expert Committee on the Technical Basis for Legislation on Irradiated Food was held in Rome on 21-28 April 1964. The Committee's report, 'The technical basis for legislation on irradiated food', was published as FAO Atomic Energy Series No.6 and WHO Technical Series No. 316. The Committee's terms of reference were to consider the available evidence on the effect on food of treatment with ionizing radiation in the context of wholesomeness and safety for consumption. Nutritional aspects were taken into account, but microbiological safety and microbiological methods for irradiated food were excluded since these subjects were believed to be too broad for adequate coverage in the working time available at the meeting. However, realizing the importance of radiation microbiology and the need for guidance in formulating regulations in this field, the committee drafted the following recommendation: 'The methods and standards used to ensure the microbiological safety of the irradiated product should, as a matter of urgency, be subject to review by competent international bodies in order that internationally acceptable methods and standards may be agreed upon'. In response to this recommendation an FAO/IAEA Panel on Microbiological Standards and Testing Methods for Irradiated Food was held in Vienna on 22-26 June 1965, in collaboration with the International Association of Microbiological Societies (IAMS). This was a working

  1. Microbiological specifications and testing methods for irradiated food. Report of a panel of experts

    1971-01-01

    In recent years there has been increased interest in the development of food items processed by means of ionizing radiation, wherever that form of preservation might show advantage over other methods. If this method becomes successful, the various items will be commercially exploited; it would then be convenient to have similar legislation in many countries of the world to control this type of processing and to facilitate international trade. To gather information and suggestions in order to devise legislation on irradiated food, a Joint FAO/IAEA/ WHO Expert Committee on the Technical Basis for Legislation on Irradiated Food was held in Rome on 21-28 April 1964. The Committee's report, 'The technical basis for legislation on irradiated food', was published as FAO Atomic Energy Series No.6 and WHO Technical Series No. 316. The Committee's terms of reference were to consider the available evidence on the effect on food of treatment with ionizing radiation in the context of wholesomeness and safety for consumption. Nutritional aspects were taken into account, but microbiological safety and microbiological methods for irradiated food were excluded since these subjects were believed to be too broad for adequate coverage in the working time available at the meeting. However, realizing the importance of radiation microbiology and the need for guidance in formulating regulations in this field, the committee drafted the following recommendation: 'The methods and standards used to ensure the microbiological safety of the irradiated product should, as a matter of urgency, be subject to review by competent international bodies in order that internationally acceptable methods and standards may be agreed upon'. In response to this recommendation an FAO/IAEA Panel on Microbiological Standards and Testing Methods for Irradiated Food was held in Vienna on 22-26 June 1965, in collaboration with the International Association of Microbiological Societies (IAMS). This was a working

  2. Microbiological specifications and testing methods for irradiated food. Report of a panel of experts

    NONE

    1970-04-01

    In recent years there has been increased interest in the development of food items processed by means of ionizing radiation, wherever that form of preservation might show advantage over other methods. If this method becomes successful, the various items will be commercially exploited; it would then be convenient to have similar legislation in many countries of the world to control this type of processing and to facilitate international trade. To gather information and suggestions in order to devise legislation on irradiated food, a Joint FAO/IAEA/ WHO Expert Committee on the Technical Basis for Legislation on Irradiated Food was held in Rome on 21-28 April 1964. The Committee's report, 'The technical basis for legislation on irradiated food', was published as FAO Atomic Energy Series No.6 and WHO Technical Series No. 316. The Committee's terms of reference were to consider the available evidence on the effect on food of treatment with ionizing radiation in the context of wholesomeness and safety for consumption. Nutritional aspects were taken into account, but microbiological safety and microbiological methods for irradiated food were excluded since these subjects were believed to be too broad for adequate coverage in the working time available at the meeting. However, realizing the importance of radiation microbiology and the need for guidance in formulating regulations in this field, the committee drafted the following recommendation: 'The methods and standards used to ensure the microbiological safety of the irradiated product should, as a matter of urgency, be subject to review by competent international bodies in order that internationally acceptable methods and standards may be agreed upon'. In response to this recommendation an FAO/IAEA Panel on Microbiological Standards and Testing Methods for Irradiated Food was held in Vienna on 22-26 June 1965, in collaboration with the International Association of Microbiological Societies (IAMS). This was a working

  3. A SKIN TEST FOR DETECTING GROUP C HEMOLYTIC STREPTOCOCCAL INFECTION CAUSING EPIZOOTIC LYMPHADENITIS IN GUINEA PIGS

    Moen, Johannes K.

    1936-01-01

    1. A skin test with a crude bacterial extract prepared from group C (Lancefield) hemolytic streptococci was used as a means of detecting possible carriers of the streptococcus causing epizootic lymphadenitis in guinea pigs. A positive test similar to a positive tuberculin reaction was considered presumptive evidence of present or recent infection with this streptococcus. 2. 20 positive reactors were found in 330 supposedly normal guinea pigs. 3. 195 negatively reacting animals were used as a breeding stock which yielded 1,296 progeny over a period of 15 months. None of the breeding stock or their progeny showed evidence of spontaneous lymphadenitis. Skin tests of 100 of the progeny were all negative. 4. The use of this skin test as a means of obtaining guinea pig breeding stock free of the streptococcus causing spontaneous lymphadenitis is suggested. PMID:19870552

  4. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    Bousquet, P.-J.; Burbach, G.; Heinzerling, L. M.; Edenharter, G.; Bachert, C.; Bindslev-Jensen, C.; Bonini, S.; Bousquet-Rouanet, L.; Demoly, P.; Bresciani, M.; Bruno, A.; Gjomarkaj, M.; Canonica, G. W.; Darsow, U.; Durham, S.; Fokkens, W. J.; Giavi, S.; Gramiccioni, C.; Papadopoulos, N. G.; Haahtela, T.; Kowalski, M. L.; Magyar, P.; Muraközi, G.; Orosz, M.; Röhnelt, C.; Stingl, G.; Todo-Bom, A.; von Mutius, E.; Wiesner, A.; Wöhrl, S.; Bousquet, J.; Zuberbier, T.

    2009-01-01

    Background: The number of allergens to be tested in order to identify sensitized patients is important in order to have the most cost-effective approach in epidemiological studies. Objective: To define the minimal number and the type of skin prick test (SPT) allergens required to identify a patient

  5. Modifications to the application of pressure to a quarter of the circumference of panel rings (tests 54 and 55)

    Van Duyse, H [INIEX

    1978-01-01

    Tests 54 and 55 were carried out on rings made up of the usual type of panel. Test 54 involved panels manufactured at Zolder and Test 55 involved those manufactured at Beringen. Both types of ring are 20 cm thick, 64 cm wide and have an internal diameter of 4.20 m. The tests involved application of pressure to one quarter of the circumference, the remainder of the ring being subject to restraint against the steel testing frame. Timber chocks were inserted between the ring and the frame. The reinforcements tested were those used with the normal type of panel. An account of deformation of the ring, cracking of the panels, and deformation of the concrete is given. Tables and figures summarizing the results achieved are included. Maximum load prior to breaking was 292 t in the case of the Zolder ring and 293 t in the case of the Beringen ring; initial cracking occurred at 35 and 30 t, respectively. (In French and in Dutch)

  6. Fabrication and laboratory-based performance testing of a building-integrated photovoltaic-thermal roofing panel

    Chen, Fangliang; Yin, Huiming

    2016-01-01

    Highlights: • A BIPVT solar panel is designed and fabricated for energy efficient buildings. • A high-speed manufacture method is developed to produce the functionally graded materials. • Laboratory tests demonstrate BIPVT’s energy efficiency improvement and innovations. • The PV efficiency is enhanced ∼24% through temperature control of the panel by water flow. • The combined electric and thermal efficiency reaches >75% of solar irradiation. - Abstract: A building integrated photovoltaic-thermal (BIPVT) multifunctional roofing panel has been developed in this study to harvest solar energy in the form of PV electricity as well as heat energy through the collection of warm water. As a key component of the multifunctional building envelope, an aluminum/high-density polyethylene (HDPE) functionally graded material (FGM) panel embedded with aluminum water tubes has been fabricated through the vibration-sedimentation approach. The FGM layer gradually transits material phases from well-conductive side (with aluminum dominated) to another highly insulated side (with HDPE). The heat in the PV cells can be easily transferred into the conductive side of the FGM and then collected by the water flow in the embedded tubes. Therefore, the operational temperature of the PV cells can be significantly lowered down, which recovers the PV efficiency in hot weather. In this way, the developed BIPVT panel is able to efficiently harvest solar energy in the form of both PV electricity and heat. The performance of a prototype BIPVT panel has been evaluated in terms of its thermal efficiency via warm water collection and PV efficiency via the output electricity. The laboratory test results demonstrate that significant energy conversion efficiency improvement can be achieved for both electricity generation and heat collection by the presented BIPVT roofing system. Overall, the performance indicates a very promising prospective of the new BIPVT multifunctional roofing panel.

  7. Concrete Flow in Diaphragm Wall Panels : A Full-Scale In-Situ Test

    Van Dalen, J.H.; Bosch, J.W.; Broere, W.

    2015-01-01

    Flow processes, taking place during the concreting of diaphragm wall panels (D-wall panels), are of great importance for the quality of the wall. During this phase, the bentonite, present in the excavated trench, should be completely replaced by concrete in a controlled way. In literature several

  8. Reliability of candida skin test in the evaluation of T-cell function in ...

    Background: Both standardized and non-standardized candida skin tests are used in clinical practice for functional in-vivo assessment of cellular immunity with variable results and are considered not reliable under the age of 1 year. We sought to investigate the reliability of using manually prepared candida intradermal test ...

  9. Studies on the prevalence of leishmanin skin test positivity in the Baringo District, Rift Valley, Kenya

    Schaefer, K. U.; Kurtzhals, J. A.; Kager, P. A.; Gachihi, G. S.; Gramiccia, M.; Kagai, J. M.; Sherwood, J. A.; Muller, A. S.

    1994-01-01

    The leishmanin skin test (LST) was applied in 26 clusters of an average of 97 individuals in Baringo District, Kenya. These clusters were centered around recent cases of visceral leishmaniasis (VL). Of 2,411 individuals tested, 254 (10.5%, 155 males and 99 females) had a positive reaction. Among

  10. In vitro and in vivo characterization of hazelnut skin prick test extracts

    Akkerdaas, Jaap H.; Wensing, Marjolein; Knulst, André C.; Aalberse, Rob C.; Hefle, Susan L.; van Ree, Ronald

    2003-01-01

    RATIONALE: Hazelnut allergy ranks among the most frequently observed food allergies. Clinical symptoms range from the oral allergy syndrome to life threatening anaphylaxis. Diagnosis of hazelnut allergy partially relies on in vivo testing by means of skin prick testing (SPT). The aim of this study

  11. Identification of low allergenic apple cultivars using skin prick tests and oral food challenges

    Vlieg-Boerstra, B. J.; van de Weg, W. E.; van der Heide, S.; Kerkhof, M.; Arens, P.; Heijerman-Peppelman, G.; Dubois, A. E. J.

    2011-01-01

    As oral allergy syndrome (OAS) symptoms to apple are frequent, we aimed to identify low allergenic apple cultivars and to validate the prick-to-prick skin prick test (SPT) as a suitable screening method. Sixty-eight apple cultivars were tested by SPTs in 33 Dutch adults with OAS, before and during

  12. Identification of low allergenic apple cultivars using skin prick tests and oral food challenges

    Vlieg-Boerstra, B. J.; van de Weg, W. E.; van der Heide, S.; Kerkhof, M.; Arens, P.; Heijerman-Peppelman, G.; Dubois, A. E. J.

    P>Background: As oral allergy syndrome (OAS) symptoms to apple are frequent, we aimed to identify low allergenic apple cultivars and to validate the prick-to-prick skin prick test (SPT) as a suitable screening method. Methods: Sixty-eight apple cultivars were tested by SPTs in 33 Dutch adults with

  13. The study of fix composite panel and steel plates on testing stand

    Wróbel, A.; Płaczek, M.; Wachna, M.

    2016-08-01

    In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".

  14. GA(2)LEN skin test study II: clinical relevance of inhalant allergen sensitizations in Europe

    Burbach, G J; Heinzerling, L M; Edenharter, G

    2009-01-01

    BACKGROUND: Skin prick testing is the standard for diagnosing IgE-mediated allergies. A positive skin prick reaction, however, does not always correlate with clinical symptoms. A large database from a Global Asthma and Allergy European Network (GA(2)LEN) study with data on clinical relevance was ...... the clinical relevance of positive skin prick tests and calls for further studies, which may, ultimately, help increase the positive predictive value of allergy testing.......BACKGROUND: Skin prick testing is the standard for diagnosing IgE-mediated allergies. A positive skin prick reaction, however, does not always correlate with clinical symptoms. A large database from a Global Asthma and Allergy European Network (GA(2)LEN) study with data on clinical relevance...... was used to determine the clinical relevance of sensitizations against the 18 most frequent inhalant allergens in Europe. The study population consisted of patients referred to one of the 17 allergy centres in 14 European countries (n = 3034, median age = 33 years). The aim of the study was to assess...

  15. A simple in chemico method for testing skin sensitizing potential of chemicals using small endogenous molecules.

    Nepal, Mahesh Raj; Shakya, Rajina; Kang, Mi Jeong; Jeong, Tae Cheon

    2018-06-01

    Among many of the validated methods for testing skin sensitization, direct peptide reactivity assay (DPRA) employs no cells or animals. Although no immune cells are involved in this assay, it reliably predicts the skin sensitization potential of a chemical in chemico. Herein, a new method was developed using endogenous small-molecular-weight compounds, cysteamine and glutathione, rather than synthetic peptides, to differentiate skin sensitizers from non-sensitizers with an accuracy as high as DPRA. The percent depletion of cysteamine and glutathione by test chemicals was measured by an HPLC equipped with a PDA detector. To detect small-size molecules, such as cysteamine and glutathione, a derivatization by 4-(4-dimethylaminophenylazo) benzenesulfonyl chloride (DABS-Cl) was employed prior to the HPLC analysis. Following test method optimization, a cut-off criterion of 7.14% depletion was applied to differentiate skin sensitizers from non-sensitizers in combination of the ratio of 1:25 for cysteamine:test chemical with 1:50 for glutathione:test chemical for the best predictivity among various single or combination conditions. Although overlapping HPLC peaks could not be fully resolved for some test chemicals, high levels of sensitivity (100.0%), specificity (81.8%), and accuracy (93.3%) were obtained for 30 chemicals tested, which were comparable or better than those achieved with DPRA. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Skin Cancer Screening

    ... Genetics of Skin Cancer Skin Cancer Screening Research Skin Cancer Screening (PDQ®)–Patient Version What is screening? ... These are called diagnostic tests . General Information About Skin Cancer Key Points Skin cancer is a disease ...

  17. Transmission of Mycobacterium tuberculosis Undetected by Tuberculin Skin Testing

    Anderson, S. T.; Williams, A. J.; Brown, J. R.; Newton, S. M.; Šimšová, Marcela; Nicol, M. P.; Šebo, Peter; Levin, M.; Wilkinson, R. J.; Wilkinson, K. A.

    2006-01-01

    Roč. 173, - (2006), s. 1038-1042 ISSN 1073-449X R&D Projects: GA AV ČR IAA5020406 Institutional research plan: CEZ:AV0Z50200510 Keywords : adenylate cyclase * diagnostic tests and procedures * mycobacterium tuberculosis Subject RIV: EE - Microbiology, Virology Impact factor: 9.091, year: 2006

  18. Diagnosis of mold allergy by RAST and skin prick testing.

    Nordvall, S L; Agrell, B; Malling, H J; Dreborg, S

    1990-11-01

    Sera from 33 patients with mold allergy proven by bronchial provocation were analyzed for specific IgE against six mold species comparing an improved Phadebas RAST with four other techniques. The new method was more sensitive and gave significantly higher IgE antibody concentrations for all tested molds except Cladosporium herbarum.

  19. Flight Test of a Technology Transparent Light Concentration Panel on SMEX/WIRE

    Stern, Theodore G.; Lyons, John

    2000-01-01

    A flight experiment has demonstrated a modular solar concentrator that can be used as a direct substitute replacement for planar photovoltaic panels in spacecraft solar arrays. The Light Concentrating Panel (LCP) uses an orthogrid arrangement of composite mirror strips to form an array of rectangular mirror troughs that reflect light onto standard, high-efficiency solar cells at a concentration ratio of approximately 3:1. The panel area, mass, thickness, and pointing tolerance has been shown to be similar to a planar array using the same cells. Concentration reduces the panel's cell area by 2/3, which significantly reduces the cost of the panel. An opportunity for a flight experiment module arose on NASA's Small Explorer / Wide-Field Infrared Explorer (SMEX/WIRE) spacecraft, which uses modular solar panel modules integrated into a solar panel frame structure. The design and analysis that supported implementation of the LCP as a flight experiment module is described. Easy integration into the existing SMEX-LITE wing demonstrated the benefits of technology transparency. Flight data shows the stability of the LCP module after nearly one year in Low Earth Orbit.

  20. Performance and Pain Tolerability of Current Diagnostic Allergy Skin Prick Test Devices.

    Tversky, Jody R; Chelladurai, Yohalakshmi; McGready, John; Hamilton, Robert G

    2015-01-01

    Allergen skin prick testing remains an essential tool for diagnosing atopic disease and guiding treatment. Sensitivity needs to be defined for newly introduced devices. Our aim was to compare the performance of 10 current allergy skin prick test devices. Single- and multiheaded skin test devices (n = 10) were applied by a single operator in a prospective randomized manner. Histamine (1 and 6 mg/mL) and control diluent were introduced at 6 randomized locations onto the upper and lower arms of healthy subjects. Wheal and flare reactions were measured independently by 2 masked technicians. Twenty-four subjects provided consent, and 768 skin tests were placed. Mean wheal diameter among devices differed from 3.0 mm (ComforTen; Hollister-Stier, Spokane, Wash) to 6.8 mm (UniTest PC; Lincoln Diagnostics, Decatur, Ill) using 1 mg/mL histamine (P Diagnostics, Decatur, Ill; and Sharp-Test; Panatrex, Placentia, Calif) using 6 mg/mL histamine (P pain score of less than 4 on a 10-point visual analog scale. Pain scores were higher among women, but this did not reach statistical significance. The Multi-Test PC and the UniTest PC had the lowest pain scores compared with the other devices. All 10 skin prick test devices displayed good analytical sensitivity and specificity; however, 3 mm cannot arbitrarily be used as a positive threshold. The use of histamine at 1 mg/mL is unacceptable for certain devices but may be preferable for the most sensitive devices. On average, there was no pain score difference between multiheaded and single-head devices. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  1. Pulse testing in the presence of wellbore storage and skin effects

    Ogbe, D.O.; Brigham, W.E.

    1984-08-01

    A pulse test is conducted by creating a series of short-time pressure transients in an active (pulsing) well and recording the observed pressure response at an observation (responding) well. Using the pressure response and flow rate data, the transmissivity and storativity of the tested formation can be determined. Like any other pressure transient data, the pulse-test response is significantly influenced by wellbore storage and skin effects. The purpose of this research is to examine the influence of wellbore storage and skin effects on interference testing in general and on pulse-testing in particular, and to present the type curves and procedures for designing and analyzing pulse-test data when wellbore storage and skin effects are active at either the responding well or the pulsing well. A mathematical model for interference testing was developed by solving the diffusivity equation for radial flow of a single-phase, slightly compressible fluid in an infinitely large, homogeneous reservoir. When wellbore storage and skin effects are present in a pulse test, the observed response amplitude is attenuated and the time lag is inflated. Consequently, neglecting wellbore storage and skin effects in a pulse test causes the calculated storativity to be over-estimated and the transmissivity to be under-estimated. The error can be as high as 30%. New correlations and procedures are developed for correcting the pulse response amplitude and time lag for wellbore storage effects. Using these correlations, it is possible to correct the wellbore storage-dominated response amplitude and time lag to within 3% of their expected values without wellbore storage, and in turn to calculate the corresponding transmissivity and storativity. Worked examples are presented to illustrate how to use the new correction techniques. 45 references.

  2. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: skin irritation.

    Macfarlane, Martin; Jones, Penny; Goebel, Carsten; Dufour, Eric; Rowland, Joanna; Araki, Daisuke; Costabel-Farkas, Margit; Hewitt, Nicola J; Hibatallah, Jalila; Kirst, Annette; McNamee, Pauline; Schellauf, Florian; Scheel, Julia

    2009-07-01

    Evaluation of the skin irritancy and corrosivity potential of an ingredient is a necessity in the safety assessment of cosmetic ingredients. To date, there are two formally validated alternatives to the rabbit Draize test for skin corrosivity in place, namely the rat skin transcutaneous electrical resistance (TER) assay and the Human Skin Model Test using EpiSkin, EpiDerm and SkinEthic reconstructed human epidermal equivalents. For skin irritation, EpiSkin, EpiDerm and SkinEthic are validated as stand-alone test replacements for the rabbit Draize test. Data from these tests are rarely considered in isolation and are evaluated in combination with other factors to establish the overall irritating or corrosive potential of an ingredient. In light of the deadlines established in the Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. In conclusion, the safety assessments for skin irritation/corrosion of new chemicals for use in cosmetics can be confidently accomplished using exclusively alternative methods.

  3. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  4. Lack of Correlation between Severity of Clinical Symptoms, Skin Test Reactivity, and Radioallergosorbent Test Results in Venom-Allergic Patients

    Warrington RJ

    2006-06-01

    Full Text Available Abstract Purpose To retrospectively examine the relation between skin test reactivity, venom-specific immunoglobulin E (IgE antibody levels, and severity of clinical reaction in patients with insect venom allergy. Method Thirty-six patients (including 15 females who presented with a history of allergic reactions to insect stings were assessed. The mean age at the time of the reactions was 33.4 ± 15.1 years (range, 4-76 years, and patients were evaluated 43.6 ± 90 months (range, 1-300 months after the reactions. Clinical reactions were scored according to severity, from 1 (cutaneous manifestations only to 3 (anaphylaxis with shock. These scores were compared to scores for skin test reactivity (0 to 5, indicating the log increase in sensitivity from 1 μg/mL to 0.0001 μg/mL and radioallergosorbent test (RAST levels (0 to 4, indicating venom-specific IgE levels, from undetectable to >17.5 kilounits of antigen per litre [kUA/L]. Results No correlation was found between skin test reactivity (Spearman's coefficient = 0.15, p = .377 or RAST level (Spearman's coefficient = 0.32, p = .061 and the severity of reaction. Skin test and RAST scores both differed significantly from clinical severity (p p = .042. There was no correlation between skin test reactivity and time since reaction (Spearman's coefficient = 0.18, p = .294 nor between RAST and time since reaction (r = 0.1353, p = .438. Elimination of patients tested more than 12 months after their reaction still produced no correlation between skin test reactivity (p = .681 or RAST score (p = .183 and the severity of the clinical reaction. Conclusion In venom-allergic patients (in contrast to reported findings in cases of inhalant IgE-mediated allergy, there appears to be no significant correlation between the degree of skin test reactivity or levels of venom-specific IgE (determined by RAST and the severity of the clinical reaction.

  5. Increased Sensitization to Mold Allergens Measured by Intradermal Skin Testing following Hurricanes.

    Saporta, Diego; Hurst, David

    2017-01-01

    Objective . To report on changes in sensitivity to mold allergens determined by changes in intradermal skin testing reactivity, after exposure to two severe hurricanes. Methods . A random, retrospective allergy charts review divided into 2 groups of 100 patients each: Group A, patients tested between 2003 and 2010 prior to hurricanes, and Group B, patients tested in 2014 and 2015 following hurricanes. Reactivity to eighteen molds was determined by intradermal skin testing. Test results, age, and respiratory symptoms were recorded. Chi-square test determined reactivity/sensitivity differences between groups. Results . Posthurricane patients had 34.6 times more positive results ( p hurricanes ( p hurricanes ( p hurricanes. This supports climatologists' hypothesis that environmental changes resulting from hurricanes can be a health risk as reflected in increased allergic sensitivities and symptoms and has significant implications for physicians treating patients from affected areas.

  6. A skin test survey of valley fever in Tijuana, Mexico.

    Fredrich, B E

    1989-01-01

    Results of a study of the prevalence of valley fever among 1128 residents of Tijuana, Baja California are presented. Children from primary and middle schools (n = 497) and adults from technical institutes and maquiladoras (assembly plants) were tested for reaction to both spherulin and coccidioidin during 1985-1986, and they completed a questionnaire containing 23 variables on their socio-environment. Place of residence was mapped. The population sampled is largely middle class. Discriminant analysis indicates the distribution of positive cases is not clustered, nor can it be correlated with geomorphic factors such as mesa tops, canyons, or valley bottoms.

  7. Proficiency testing of skin prick testers as part of a quality assurance system

    Malling, Hans-Jørgen; Allesen-Holm, Pernille; Karved, Lisbeth Sys

    2016-01-01

    BACKGROUND: Skin prick test is an important diagnostic procedure in clinical allergy but documentation of the quality is often missing. METHODS: We describe a proficiency system to evaluate staff members in relation to the international recommended reproducibility in terms of coefficient...... of variation (CV 0.85) based on blinded octuplicate histamine testing using histamine 3, 10, 30 and 100 mg/ml. RESULTS: Fourteen trained allergy nurses participated in the proficiency testing. More than 95 % of the nurses, generated coefficient of variation...

  8. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy.

    Tannert, Line Kring; Mortz, Charlotte Gotthard; Skov, Per Stahl; Bindslev-Jensen, Carsten

    According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. To investigate the clinical relevance of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged, but deemed allergic on the basis of a recent anaphylactic reaction or delayed reactions to skin testing. Another sample of convenience of 18 patients, 17 overlapping with the 25 challenged, with initial skin testing and s-IgE (median, 25; range, 3-121), months earlier (T -1 ), was repeat skin tested and had s-IgE measured (T 0 ), and then skin tested and had s-IgE measured 4 weeks later (T 1 ). Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T 0 . Positive ST result or positive s-IgE alone did not predict penicillin allergy. Among the 18 patients repeatedly tested, 46.2% (12 of 25) of positive ST results at T -1 were reproducibly positive at T 0 . For s-IgE, 54.2% (14 of 24) positive measurements were still positive at T 0 and 7 converted to positive at T 1 . The best predictor for a clinically significant (IgE-mediated) penicillin allergy is a combination of a positive case history with simultaneous positive ST result and s-IgE or a positive challenge result. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  9. Skin test concentrations for systemically administered drugs -- an ENDA/EAACI Drug Allergy Interest Group position paper

    Brockow, K.; Garvey, L. H.; Aberer, W.; Atanaskovic-Markovic, M.; Barbaud, A.; Bilo, M. B.; Bircher, A.; Blanca, M.; Bonadonna, B.; Campi, P.; Castro, E.; Cernadas, J. R.; Chiriac, A. M.; Demoly, P.; Grosber, M.; Gooi, J.; Lombardo, C.; Mertes, P. M.; Mosbech, H.; Nasser, S.; Pagani, M.; Ring, J.; Romano, A.; Scherer, K.; Schnyder, B.; Testi, S.; Torres, M.; Trautmann, A.; Terreehorst, I.

    2013-01-01

    Skin tests are of paramount importance for the evaluation of drug hypersensitivity reactions. Drug skin tests are often not carried out because of lack of concise information on specific test concentrations. The diagnosis of drug allergy is often based on history alone, which is an unreliable

  10. Comparison of two interferon-gamma assays and tuberculin skin test for tracing tuberculosis contacts

    Arend, Sandra M.; Thijsen, Steven F. T.; Leyten, Eliane M. S.; Bouwman, John J. M.; Franken, Willeke P. J.; Koster, Ben F. P. J.; Cobelens, Frank G. J.; van Houte, Arend-Jan; Bossink, Ailko W. J.

    2007-01-01

    The tuberculin skin test (TST) has low specificity. QuantiFERON-TB Gold (QFT-G) and T-SPOT.TB are based on interferon (IFN)-gamma responses to Mycobacterium tuberculosis-specific antigens. A novel in-tube format of QFT-G (QFT-GIT) offers logistical advantages. To compare TST, QFT-GIT, and T-SPOT.TB

  11. Dragon Skin - How It Changed Body Armor Testing in the United States Army

    2015-09-01

    members of this committee who have their kids at one time or another wearing body armor in theater, either Iraq or Afghanistan. And that includes... YouTube has pictures of Dragon Skin body armor testing on the Internet and Wikipedia has posted a carefully documented description of the history of

  12. Development and characterisation of an in vitro photomicronucleus test using ex vivo human skin tissue

    Reus, A.A.; Meeuwen, R.N.C. van; Vogel, N. de; Maas, W.J.M.; Krul, C.A.M.

    2011-01-01

    Photosafety testing is of concern for the evaluation of personal care products and pharmaceuticals. Current regulatory guidance state that photosafety should be evaluated for compounds that absorb radiation between 290 and 700 nm with relevant exposure in the skin or eyes. However, oversensitivity

  13. Tuberculin skin testing in patients with HIV infection: limited benefit of reduced cutoff values

    Cobelens, Frank G.; Egwaga, Saidi M.; van Ginkel, Tessa; Muwinge, Hemed; Matee, Mecky I.; Borgdorff, Martien W.

    2006-01-01

    BACKGROUND: When determining eligibility for isoniazid preventive therapy of human immunodeficiency virus (HIV)-infected patients, the cutoff value of the tuberculin skin test (TST) is often reduced from an induration of 10 mm in diameter to one of 5 mm in diameter to compensate for loss of

  14. TEST performance of a myositis panel in a clinical immunology laboratory in New South Wales, Australia.

    Tan, Teck Choon; Wienholt, Louise; Adelstein, Stephen

    2016-10-01

    There is increasing recognition of a clinico-serological correlation between the idiopathic inflammatory myopathies and myositis-specific autoantibodies (MSA). We review the use of a line immunoassay-based myositis panel incorporating both MSA and myositis-associated autoantibodies (MAA) in a selected population of patients. A retrospective analysis of patients with myositis panel assays performed in 2013 were reviewed and compared against clinical diagnoses. A total of 96 patient samples were evaluated, the clinical indications include 60 patients with suspected idiopathic inflammatory myositis (IIM), 24 patients with suspected interstitial lung disease (ILD) and 12 patients with suspected systemic autoimmune disease (SAD). In the myositis group, there were 21 patients diagnosed with IIM and 18 patients diagnosed with IIM had a positive myositis panel. Of the 39 patients without IIM, nine of these patients had a positive myositis panel. In the ILD group, 10 of 24 patients had a positive myositis panel; of these, two were diagnosed anti-synthetase syndrome (ASS) and five patients with ILD. In the suspected SAD group, three had positive myositis panel and all did not appear associated with their final diagnoses. In patients with a clinical diagnosis of IIM or ILD-associated SAD, four patients with anti-PL-12 were detected, three patients with anti-signal recognition protein, two patients with anti-Jo-1, and two patients with anti-Mi2. The myositis panel is an objective investigative modality with a sensitivity of 80.00% and a specificity of 75.76% in a setting of high pretest clinical suspicion. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  15. Residual Strength Pressure Tests and Nonlinear Analyses of Stringer- and Frame-Stiffened Aluminum Fuselage Panels with Longitudinal Cracks

    Young, Richard D.; Rouse, Marshall; Ambur, Damodar R.; Starnes, James H., Jr.

    1999-01-01

    The results of residual strength pressure tests and nonlinear analyses of stringer- and frame-stiffened aluminum fuselage panels with longitudinal cracks are presented. Two types of damage are considered: a longitudinal crack located midway between stringers, and a longitudinal crack adjacent to a stringer and along a row of fasteners in a lap joint that has multiple-site damage (MSD). In both cases, the longitudinal crack is centered on a severed frame. The panels are subjected to internal pressure plus axial tension loads. The axial tension loads are equivalent to a bulkhead pressure load. Nonlinear elastic-plastic residual strength analyses of the fuselage panels are conducted using a finite element program and the crack-tip-opening-angle (CTOA) fracture criterion. Predicted crack growth and residual strength results from nonlinear analyses of the stiffened fuselage panels are compared with experimental measurements and observations. Both the test and analysis results indicate that the presence of MSD affects crack growth stability and reduces the residual strength of stiffened fuselage shells with long cracks.

  16. Course of Skin Symptoms and Quality of Life in Children Referred for Patch Testing

    Simonsen, Anne B; Sommerlund, Mette; Deleuran, Mette

    2015-01-01

    Children are patch tested in the same manner as adults, but little has been done to establish whether positive or negative findings influence the course of skin symptoms. To uncover the course of skin symptoms and the impact of persistent eczema on life quality in paediatric patients referred...... to follow-up. Among patients without atopic dermatitis, 23.5% reported to suffer from chronic eczema. Persistent eczema increased the risk of severe impairment of life quality. Our findings indicate a significant risk of childhood eczema becoming chronic and affecting life quality considerably. Patch...

  17. Hypersensitivity reactions to penicillins: studies in a group of patients with negative benzylpenicillin G skin test.

    Qiao, H-L; Li, Z; Yang, J; Tian, X; Gao, N; Jia, L-J

    2009-06-01

    Although skin tests are usually employed to evaluate current penicillin allergy status, a negative result does not exclude hypersensitivity. There is a need for accurate in vitro tests to exclude hypersensitivity. A radioallergosorbent test (RAST) is a potentially good supplementary approach, but there is little information on the suitability of this method to diagnose penicillin hypersensitivity in subjects with a negative skin test to benzylpenicillin. A total of 133 patients with a negative skin test to benzylpenicillin G (PG) and all of whom developed allergic reactions to PG were studied. RAST was used to detect eight kinds of specific IgE antibodies to penicillins in serum, which included four kinds of major and minor antigenic determinants to four penicillin drugs. The combination sites for the specific IgE antibodies were studied by RAST inhibition test. The rate of positive reactions for the specific IgE antibodies was 59.40% (79/133). Of the eight kinds of antigenic determinants, the positive rates for specific IgE against the major and minor determinants were 39.10% (52) and 42.86% (57) respectively. Of the four drugs, positive cases only to PG were 10 (7.5%), were significantly fewer than the cross-reacting positive cases (36) to PG (P penicillins could induce specific responses with a variable degree of cross-reactivity among the different penicillins. Radioallergosorbent test is a good complementary test in persons who are skin-test negative with PG, and the sensitivity of RAST increases with increasing specificity of IgE antibodies to be detected. 6-APA and the groups, making part of the different side-chains on penicillins, all contributed to the cross-reactivity.

  18. The adverse outcome pathway for skin sensitisation: Moving closer to replacing animal testing.

    Schultz, Terry W; Dimitrova, Gergana; Dimitrov, Sabcho; Mekenyan, Ovanes G

    2016-10-01

    This article outlines the work of the Organisation for Economic Co-operation and Development (OECD) that led to being jointly awarded the 2015 Lush Black Box Prize. The award-winning work centred on the development of 'The Adverse Outcome Pathway for Skin Sensitisation Initiated by Covalent Binding to Proteins'. This Adverse Outcome Pathway (AOP) has provided the mechanistic basis for the integration of skin sensitisation-related information. Recent developments in integrated approaches to testing and assessment, based on the AOP, are summarised. The impact of the AOP on regulatory policy and on the Three Rs are discussed. An overview of the next generation of the skin sensitisation AOP module in the OECD QSAR Toolbox, based on more-recent work at the Laboratory of Mathematical Chemistry, is also presented. 2016 FRAME.

  19. Biodegradable Polymers Induce CD54 on THP-1 Cells in Skin Sensitization Test.

    Jung, Yeon Suk; Kato, Reiko; Tsuchiya, Toshie

    2011-01-01

    Currently, nonanimal methods of skin sensitization testing for various chemicals, biodegradable polymers, and biomaterials are being developed in the hope of eliminating the use of animals. The human cell line activation test (h-CLAT) is a skin sensitization assessment that mimics the functions of dendritic cells (DCs). DCs are specialized antigen-presenting cells, and they interact with T cells and B cells to initiate immune responses. Phenotypic changes in DCs, such as the production of CD86 and CD54 and internalization of MHC class II molecules, have become focal points of the skin sensitization test. In this study, we used h-CLAT to assess the effects of biodegradable polymers. The results showed that several biodegradable polymers increased the expression of CD54, and the relative skin sensitizing abilities of biodegradable polymers were PLLG (75 : 25) < PLLC (40 : 60) < PLGA (50 : 50) < PCG (50 : 50). These results may contribute to the creation of new guidelines for the use of biodegradable polymers in scaffolds or allergenic hazards.

  20. Biodegradable Polymers Induce CD54 on THP-1 Cells in Skin Sensitization Test

    Yeon Suk Jung

    2011-01-01

    Full Text Available Currently, nonanimal methods of skin sensitization testing for various chemicals, biodegradable polymers, and biomaterials are being developed in the hope of eliminating the use of animals. The human cell line activation test (h-CLAT is a skin sensitization assessment that mimics the functions of dendritic cells (DCs. DCs are specialized antigen-presenting cells, and they interact with T cells and B cells to initiate immune responses. Phenotypic changes in DCs, such as the production of CD86 and CD54 and internalization of MHC class II molecules, have become focal points of the skin sensitization test. In this study, we used h-CLAT to assess the effects of biodegradable polymers. The results showed that several biodegradable polymers increased the expression of CD54, and the relative skin sensitizing abilities of biodegradable polymers were PLLG (75 : 25 < PLLC (40 : 60 < PLGA (50 : 50 < PCG (50 : 50. These results may contribute to the creation of new guidelines for the use of biodegradable polymers in scaffolds or allergenic hazards.

  1. Full-thickness human skin explants for testing the toxicity of topically applied chemicals

    Nakamura, M.; Rikimaru, T.; Yano, T.; Moore, K.G.; Pula, P.J.; Schofield, B.H.; Dannenberg, A.M. Jr.

    1990-01-01

    This report describes a model organ-culture system for testing the toxicity of chemical substances that are topically applied to human skin. In this system, the viable keratinocytes in the full-thickness skin explants are protected by the same keratinized layer as skin remaining on the donor, and toxicity can be assessed microscopically and/or biochemically. The human skin specimens were discards from a variety of surgical procedures. They were cut into full-thickness 1.0-cm2 explants, and briefly exposed to the military vesicant sulfur mustard (SM), which was used as a model toxicant. The explants were then organ cultured in small Petri dishes for 24 h at 36 degrees C. In the 0.03-1.0% dosage range, a straight-line dose-response relationship occurred between the concentration of SM applied and the number of paranuclear vacuoles seen histologically in the epidermis. Within the same SM dosage range, there was also a proportional decrease in 14C-leucine incorporation by the explants. Thus, the number of paranuclear vacuoles reflected decreases in protein synthesis by the injured epidermal cells. The epidermis of full-thickness untreated (control) human skin explants usually remained viable for 7 d when stored at 4 degrees C in culture medium. During storage, a relatively small number of paranuclear vacuoles developed within the epidermis, but the explants were still quite satisfactory for testing SM toxicity. Incubation (for 4 or 24 h at 36 degrees C) of such control skin explants reduced (often by 50%) the small number of paranuclear vacuoles produced during 4-7 d of storage. This reduction was probably caused by autolysis of many of the vacuolated cells. Two types of paranuclear vacuoles could be identified by both light and electron microscopy: a storage type and a toxicant type. The storage type seemed to be caused by autolysis of cell components

  2. Full-thickness human skin explants for testing the toxicity of topically applied chemicals

    Nakamura, M.; Rikimaru, T.; Yano, T.; Moore, K.G.; Pula, P.J.; Schofield, B.H.; Dannenberg, A.M. Jr. (Johns Hopkins Univ., Baltimore, MD (USA))

    1990-09-01

    This report describes a model organ-culture system for testing the toxicity of chemical substances that are topically applied to human skin. In this system, the viable keratinocytes in the full-thickness skin explants are protected by the same keratinized layer as skin remaining on the donor, and toxicity can be assessed microscopically and/or biochemically. The human skin specimens were discards from a variety of surgical procedures. They were cut into full-thickness 1.0-cm2 explants, and briefly exposed to the military vesicant sulfur mustard (SM), which was used as a model toxicant. The explants were then organ cultured in small Petri dishes for 24 h at 36 degrees C. In the 0.03-1.0% dosage range, a straight-line dose-response relationship occurred between the concentration of SM applied and the number of paranuclear vacuoles seen histologically in the epidermis. Within the same SM dosage range, there was also a proportional decrease in 14C-leucine incorporation by the explants. Thus, the number of paranuclear vacuoles reflected decreases in protein synthesis by the injured epidermal cells. The epidermis of full-thickness untreated (control) human skin explants usually remained viable for 7 d when stored at 4 degrees C in culture medium. During storage, a relatively small number of paranuclear vacuoles developed within the epidermis, but the explants were still quite satisfactory for testing SM toxicity. Incubation (for 4 or 24 h at 36{degrees}C) of such control skin explants reduced (often by 50%) the small number of paranuclear vacuoles produced during 4-7 d of storage. This reduction was probably caused by autolysis of many of the vacuolated cells. Two types of paranuclear vacuoles could be identified by both light and electron microscopy: a storage type and a toxicant type. The storage type seemed to be caused by autolysis of cell components.

  3. Hepatitis virus panel

    ... page: //medlineplus.gov/ency/article/003558.htm Hepatitis virus panel To use the sharing features on this page, please enable JavaScript. The hepatitis virus panel is a series of blood tests used ...

  4. Antinuclear antibody panel

    ... page: //medlineplus.gov/ency/article/003535.htm Antinuclear antibody panel To use the sharing features on this page, please enable JavaScript. The antinuclear antibody panel is a blood test that looks at ...

  5. Evaluation of autologous serum skin test and skin prick test reactivity to house dust mite in patients with chronic spontaneous urticaria.

    Zhiqiang Song

    Full Text Available BACKGROUND: Chronic spontaneous urticaria (CSU is a common skin disorder with etiology that is not well understood. METHODS: In this study, we evaluated the prevalence of autologous serum skin test (ASST and skin prick testing (SPT to house dust mite (HDM in 862 CSU cases in China. Clinical features, courses and treatment responses were also recorded. RESULTS: The prevalence of positive ASST was 46.3%, and patients aged 30-39 years had the highest positive rate (52.1%. Positive SPT to HDM was seen in 153 patients (17.7% with the highest positive rate (34.2% in patients aged 20 or less. Patients with positive ASST had higher urticaria activity scores (UAS (4.18±0.65 vs. 3.67±0.53 but lower positive rates of HDM (24.6% vs. 37.6%, as compared with those with negative ASST (odds ratio (OR 1.84, 95% CI 1.38-2.47. Patients could be categorized into four groups based on the results of ASST and SPT to HDM and patients with positive ASST and positive SPT to HDM had the highest disease activity scores, experienced higher frequencies of angioedema, diseases duration, and required higher dosage of loratadine every month, compared with other subgroups (P<0.0001. CONCLUSIONS: Patients with CSU showed varied responses of positive ASST and varied sensitivity to HDM, Patients with positive ASST and/or positive SPT had more disease activity compared with patients with negative ASST and/or negative SPT. Further classification can be made based on the result of SPT and ASST.

  6. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  7. A comprehensive custom panel design for routine hereditary cancer testing: preserving control, improving diagnostics and revealing a complex variation landscape.

    Castellanos, Elisabeth; Gel, Bernat; Rosas, Inma; Tornero, Eva; Santín, Sheila; Pluvinet, Raquel; Velasco, Juan; Sumoy, Lauro; Del Valle, Jesús; Perucho, Manuel; Blanco, Ignacio; Navarro, Matilde; Brunet, Joan; Pineda, Marta; Feliubadaló, Lidia; Capellá, Gabi; Lázaro, Conxi; Serra, Eduard

    2017-01-04

    We wanted to implement an NGS strategy to globally analyze hereditary cancer with diagnostic quality while retaining the same degree of understanding and control we had in pre-NGS strategies. To do this, we developed the I2HCP panel, a custom bait library covering 122 hereditary cancer genes. We improved bait design, tested different NGS platforms and created a clinically driven custom data analysis pipeline. The I2HCP panel was developed using a training set of hereditary colorectal cancer, hereditary breast and ovarian cancer and neurofibromatosis patients and reached an accuracy, analytical sensitivity and specificity greater than 99%, which was maintained in a validation set. I2HCP changed our diagnostic approach, involving clinicians and a genetic diagnostics team from panel design to reporting. The new strategy improved diagnostic sensitivity, solved uncertain clinical diagnoses and identified mutations in new genes. We assessed the genetic variation in the complete set of hereditary cancer genes, revealing a complex variation landscape that coexists with the disease-causing mutation. We developed, validated and implemented a custom NGS-based strategy for hereditary cancer diagnostics that improved our previous workflows. Additionally, the existence of a rich genetic variation in hereditary cancer genes favors the use of this panel to investigate their role in cancer risk.

  8. Will initiatives to promote hydroelectricity consumption be effective? Evidence from univariate and panel LM unit root tests with structural breaks

    Lean, Hooi Hooi; Smyth, Russell

    2014-01-01

    This paper examines whether initiatives to promote hydroelectricity consumption are likely to be effective by applying univariate and panel Lagrange Multiplier (LM) unit root tests to hydroelectricity consumption in 55 countries over the period 1965–2011. We find that for the panel, as well as about four-fifths of individual countries, that hydroelectricity consumption is stationary. This result implies that shocks to hydroelectricity consumption in most countries will only result in temporary deviations from the long-run growth path. An important consequence of this finding is that initiatives designed to have permanent positive effects on hydroelectricity consumption, such as large-scale dam construction, are unlikely to be effective in increasing the share of hydroelectricity, relative to consumption of fossil fuels. - Highlights: • Applies unit root tests to hydroelectricity consumption. • Hydroelectricity consumption is stationary. • Shocks to hydroelectricity consumption result in temporary deviations from the long-run growth path

  9. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults.

    Kim, Sung Ryeol; Park, Hye Jung; Park, Kyung Hee; Lee, Jae-Hyun; Park, Jung-Won

    2016-08-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was detected most frequently, at a rate of 25.4%. Sensitization rates to other food allergens were as follows: maize grain (13.4%), shrimp (11.9%), almond (11.1%), wheat flour (8.2%), lobster (8.2%), buckwheat (8.2%), mackerel (5.2%), pollack (5.2%), halibut (4.5%), peanut (4.5%), anchovy (4.4%), squid (3.7%), saury (3.0%), common eel (3.0%), yellow corvina (3.0%), hairtail (2.2%), octopus (2.2%), and others. In addition to well-known food allergens, sensitivity to mackerel, chrysalis, pollack, and halibut, which are popular foods in Korea, was observed at high rates in Korean adults. We suggest that the SPT panel for food allergy in Korea should include these allergens.

  10. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults

    2016-01-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was detected most frequently, at a rate of 25.4%. Sensitization rates to other food allergens were as follows: maize grain (13.4%), shrimp (11.9%), almond (11.1%), wheat flour (8.2%), lobster (8.2%), buckwheat (8.2%), mackerel (5.2%), pollack (5.2%), halibut (4.5%), peanut (4.5%), anchovy (4.4%), squid (3.7%), saury (3.0%), common eel (3.0%), yellow corvina (3.0%), hairtail (2.2%), octopus (2.2%), and others. In addition to well-known food allergens, sensitivity to mackerel, chrysalis, pollack, and halibut, which are popular foods in Korea, was observed at high rates in Korean adults. We suggest that the SPT panel for food allergy in Korea should include these allergens. PMID:27478328

  11. Unit root tests for cross-sectionally dependent panels : The influence of observed factors

    Becheri, I.G.; Drost, F.C.; van den Akker, R.

    This paper considers a heterogeneous panel unit root model with cross-sectional dependence generated by a factor structure—the factor common to all units being an observed covariate. The model is shown to be Locally Asymptotically Mixed Normal (LAMN), with the random part of the limiting Fisher

  12. Research Program Tests for the U.S. Defense Special Weapons Agency (DSWA) for Breaching of Concrete Panels Set Against a Sandstone Rock Wall

    Harvey, Kent

    2006-01-01

    ...) Determine the difficulties and nuances of drilling behind wall test panels 3) Test different blast hole sizes, blast hole locations, and blasting sequences in an effort to identify the advantages and disadvantages of different breaching approaches...

  13. [Diagnostic capacity of skin prick test in egg and cow's milk allergic infants].

    Yan, Jun-mei; Chen, Jing; Li, Hai-qi; Hu, Yan

    2011-05-01

    Mean diameter is the most common used parameter for wheal response assessment after skin prick test. This study aimed to investigate the diagnostic capacity of mean diameter according to the outcome of oral food challenge, and to determine the cut-off points that could render food challenges unnecessary. Data of 173 children referred to the Division of Primary Child Health Care for the evaluation of suspected food allergy were prospectively studied. All children underwent skin prick test and open food challenge to the relevant food(s) in clinic. The mean wheal diameter of skin prick test was measured, and open food challenge was performed to confirm food allergy. The SPSS software package version 13.0 for windows (SPSS, Chicago, IL, USA) was used for all statistical analysis. Open food challenge was taken as the gold standard for diagnosis. Diagnostic capacity of skin prick test, including the sensitivity, specificity, positive predictive value, negative predictive value, was calculated by cross-table. In addition, receiver operating characteristic curve (ROC) was plotted and area under the curve (AUC) was calculated to quantify the accuracy of the parameter. For the 173 children, 271 open food challenges were performed with egg white, egg yolk and cow's milk, In which 123 were positive, 99 children were diagnosed as food allergy. Cutaneous symptoms (87.0%) were most common, followed by gastrointestinal symptoms (9.8%). The AUC of mean diameter was 0.794 for egg white, 0.804 for egg yolk and 0.904 for cow's milk. The sensitivity of skin prick test with a cut-off value of ≥ 3 mm was ranged from 71% to 87%, while the specificity was between 31% and 57%. The authors also defined food specific skin prick test mean diameters that were 100% diagnostic for allergy to egg white (≥ 8.5 mm), egg yolk (≥ 5.5 mm), cow's milk (≥ 5.5 mm). Predictive decision points for a positive outcome of food challenges can be calculated for egg and cow's milk using mean diameter. It

  14. Determining Damping Trends from a Range of Cable Harness Assemblies on a Launch Vehicle Panel from Test Measurements

    Smith, Andrew; Davis, R. Ben; LaVerde, Bruce; Jones, Douglas

    2012-01-01

    The team of authors at Marshall Space Flight Center (MSFC) has been investigating estimating techniques for the vibration response of launch vehicle panels excited by acoustics and/or aero-fluctuating pressures. Validation of the approaches used to estimate these environments based on ground tests of flight like hardware is of major importance to new vehicle programs. The team at MSFC has recently expanded upon the first series of ground test cases completed in December 2010. The follow on tests recently completed are intended to illustrate differences in damping that might be expected when cable harnesses are added to the configurations under test. This validation study examines the effect on vibroacoustic response resulting from the installation of cable bundles on a curved orthogrid panel. Of interest is the level of damping provided by the installation of the cable bundles and whether this damping could be potentially leveraged in launch vehicle design. The results of this test are compared with baseline acoustic response tests without cables. Damping estimates from the measured response data are made using a new software tool that employs a finite element model (FEM) of the panel in conjunction with advanced optimization techniques. This paper will report on the \\damping trend differences. observed from response measurements for several different configurations of cable harnesses. The data should assist vibroacoustics engineers to make more informed damping assumptions when calculating vibration response estimates when using model based analysis approach. Achieving conservative estimates that have more flight like accuracy is desired. The paper may also assist analysts in determining how ground test data may relate to expected flight response levels. Empirical response estimates may also need to be adjusted if the measured response used as an input to the study came from a test article without flight like cable harnesses.

  15. Assuring consumer safety without animal testing: a feasibility case study for skin sensitisation.

    Maxwell, Gavin; Aleksic, Maja; Aptula, Aynur; Carmichael, Paul; Fentem, Julia; Gilmour, Nicola; Mackay, Cameron; Pease, Camilla; Pendlington, Ruth; Reynolds, Fiona; Scott, Daniel; Warner, Guy; Westmoreland, Carl

    2008-11-01

    Allergic Contact Dermatitis (ACD; chemical-induced skin sensitisation) represents a key consumer safety endpoint for the cosmetics industry. At present, animal tests (predominantly the mouse Local Lymph Node Assay) are used to generate skin sensitisation hazard data for use in consumer safety risk assessments. An animal testing ban on chemicals to be used in cosmetics will come into effect in the European Union (EU) from March 2009. This animal testing ban is also linked to an EU marketing ban on products containing any ingredients that have been subsequently tested in animals, from March 2009 or March 2013, depending on the toxicological endpoint of concern. Consequently, the testing of cosmetic ingredients in animals for their potential to induce skin sensitisation will be subject to an EU marketing ban, from March 2013 onwards. Our conceptual framework and strategy to deliver a non-animal approach to consumer safety risk assessment can be summarised as an evaluation of new technologies (e.g. 'omics', informatics), leading to the development of new non-animal (in silico and in vitro) predictive models for the generation and interpretation of new forms of hazard characterisation data, followed by the development of new risk assessment approaches to integrate these new forms of data and information in the context of human exposure. Following the principles of the conceptual framework, we have been investigating existing and developing new technologies, models and approaches, in order to explore the feasibility of delivering consumer safety risk assessment decisions in the absence of new animal data. We present here our progress in implementing this conceptual framework, with the skin sensitisation endpoint used as a case study. 2008 FRAME.

  16. The value of Tzanck smear test in diagnosis of erosive, vesicular, bullous, and pustular skin lesions.

    Durdu, Murat; Baba, Mete; Seçkin, Deniz

    2008-12-01

    Tzanck smear is generally used for the diagnosis of the pemphigus group of autoimmune bullous diseases and mucocutaneous herpesvirus infections. There are only a few studies in the literature investigating its diagnostic value. We aimed to investigate Tzanck smear findings and to determine the diagnostic value of this test in moist (erosive, vesicular, bullous, and pustular) skin lesions. We also aimed to develop an algorithmic approach for the diagnosis of these types of skin lesions according to the Tzanck smear findings. Samples were stained with May-Grünwald-Giemsa and evaluated by the same dermatologist. In some patients, methylene blue and Gram staining or direct immunofluorescence examinations were additionally performed. In all of the study cases, after the evaluation of clinical and laboratory findings (including, when appropriate, potassium hydroxide examination; viral serology; bacterial and fungal cultures; histopathology; direct and indirect immunofluorescence; patch testing), the definite diagnosis was established. We also determined the sensitivity and the specificity of certain Tzanck smear findings. Tzanck smear was performed in a total of 400 patients with moist skin lesions. The sensitivities of multinucleated giant cells and acantholytic cells in herpetic infections, dyskeratotic acantholytic cells and cocci in bullous impetigo, pseudohyphae in candidiasis, acantholytic cells in pemphigus and more than 10 tadpole cells (magnification x100) in spongiotic dermatitis were 84.7%, 92%, 100%, 100%, and 81.5%, respectively. Because Tzanck smears were evaluated by the same dermatologist, no comment could be made regarding the interobserver reliability of this test and how the level of experience with this technique might affect the results. Also, the sensitivity and the specificity of Tzanck smear test findings for certain diseases could not be calculated because of an insufficient number of patients. The Tzanck smear test is an inexpensive, useful

  17. Testing and Analysis of the Peeling of Medical Adhesives From Human Skin

    Karwoski, Alicia Corrine

    2003-01-01

    The analysis of peeling tape or a bandage from skin is a challenging problem. Skin is a very complex material made of many layers with anisotropic material properties. Adhesives that bond tapes or patches to skin must attach to skin through moisture and skin movement, but then be removed with little skin trauma. A computer model of peeling from skin apparently has not been developed previously. With experiments and the application of mechanics, research was conducted to analyze adhesion to sk...

  18. Development, standardization and testing of a bacterial wound infection model based on ex vivo human skin.

    Christoph Schaudinn

    Full Text Available Current research on wound infections is primarily conducted on animal models, which limits direct transferability of these studies to humans. Some of these limitations can be overcome by using-otherwise discarded-skin from cosmetic surgeries. Superficial wounds are induced in fresh ex vivo skin, followed by intradermal injection of Pseudomonas aeruginosa under the wound. Subsequently, the infected skin is incubated for 20 hours at 37°C and the CFU/wound are determined. Within 20 hours, the bacteria count increased from 107 to 109 bacteria per wound, while microscopy revealed a dense bacterial community in the collagen network of the upper wound layers as well as numerous bacteria scattered in the dermis. At the same time, IL-1alpha and IL-1beta amounts increased in all infected wounds, while-due to bacteria-induced cell lysis-the IL-6 and IL-8 concentrations rose only in the uninfected samples. High-dosage ciprofloxacin treatment resulted in a decisive decrease in bacteria, but consistently failed to eradicate all bacteria. The main benefits of the ex vivo wound model are the use of healthy human skin, a quantifiable bacterial infection, a measureable donor-dependent immune response and a good repeatability of the results. These properties turn the ex vivo wound model into a valuable tool to examine the mechanisms of host-pathogen interactions and to test antimicrobial agents.

  19. A Preliminary Test for Skin Gas Assessment Using a Porphyrin Based Evanescent Wave Optical Fiber Sensor

    Roman SELYANCHYN

    2011-02-01

    Full Text Available An evanescent-wave optical fibre sensor modified with tetrakis-(4-sulfophenyl porphine (TSPP and poly(allylamine hydrochloride (PAH bilayers using layer-by-layer (LbL electrostatic self-assembly was tested to measure the gas emitted from human skin. Optical intensity changes at different wavelengths in the transmission spectrum of the porphyrin-based film were induced by the human skin gas and measured as sensor response. Influence of relative humidity, which can be a major interference to sensor response, was thoroughly studied and shown to be significantly different when compared to the influence of skin emanations. Responses of the current optical sensor system could be considered as composite sensor array, where different optical wavelengths act as channels that have selective response to specific volatile compounds. Data obtained from the sensor system was analyzed using principal component analysis (PCA. This approach enabled to distinguish skin odors of different people and their altered physiological conditions after alcohol consumption.

  20. Assessment of biofouling community development on test panels submerged in Kudankulam coast with special reference to the Nuclear Power Project

    Satheesh, S.; Wesley, S. Godwin

    2008-01-01

    Biofouling is known to be one of the common problems in cooling water systems of power plants and several incidents of plant shutdown have been reported from various parts of the world. The settlement of marine organisms on an exposed hard surface depends obviously on the species, which are naturally present at a given site as well as their ability to attach and grow on that surface. Information on the organisms forming the fouling complex is necessary in view of the damages they cause to various marine structures and for devising protective measures. The present paper reports the results of the investigations of biofouling carried out for a period of two years from November 2003 to October 2004 at Kudankulam coast where a mega nuclear power project is under construction. Wooden test panels (10x10x3 cm) were fitted to a raft and submerged in the coastal waters. Total fouling biomass, thickness, coverage and community composition were analysed from the panels. Barnacles, mussels, ascidians, polychaetes, amphipods and seaweeds were the common fouling groups settled on the test panels. The total biomass reached to a maximum of 69.9 g.dm -2 (dry weight) after 330 days of exposure. The fouling thickness reached a maximum of 42.3 mm after 225 days of exposure. Results also showed a strong temporal variation in the fouling community recruitment. Based on the observations, Kudankulam coast could be categorized as a moderate fouling station mainly due to the low abundance of mussels in this region. (author)

  1. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  2. Sensitization to Food Additives in Patients with Allergy: A Study Based on Skin Test and Open Oral Challenge.

    Moghtaderi, Mozhgan; Hejrati, Zinatosadat; Dehghani, Zahra; Dehghani, Faranak; Kolahi, Niloofar

    2016-06-01

    There has been a great increase in the consumption of various food additives in recent years. The purpose of this study was to identify the incidence of sensitization to food additives by using skin prick test in patients with allergy and to determine the concordance rate between positive skin tests and oral challenge in hypersensitivity to additives. This cross-sectional study included 125 (female 71, male 54) patients aged 2-76 years with allergy and 100 healthy individuals. Skin tests were performed in both patient and control groups with 25 fresh food additives. Among patients with allergy, 22.4% showed positive skin test at least to one of the applied materials. Skin test was negative to all tested food additives in control group. Oral food challenge was done in 28 patients with positive skin test, in whom 9 patients showed reaction to culprit (Concordance rate=32.1%). The present study suggested that about one-third of allergic patients with positive reaction to food additives showed positive oral challenge; it may be considered the potential utility of skin test to identify the role of food additives in patients with allergy.

  3. Evaluation of Precast Panels for Airfield Pavement Repair. Phase 1: System Optimization and Test Section Construction

    2013-06-01

    provided the most eccentric loading. Configurations with multiple wheel loads on the panel at one time were converted to a composite eccentric load at...Bearing capacity (safety factor), lb/in.2 Type Considered Main gear wheels considered load, kip Eccentricity from center x, in. y, in...dimensions were typically 12 ft x 12 ft x 10 in. with three 1.5-in.-diameter dowel bars cast in the wheel paths to ensure load transfer across the joints

  4. A Test for Parameter Homogeneity in CO2Panel EKC Estimations

    Dijkgraaf, E.; Vollebergh, H.R.J.

    2005-01-01

    This paper casts doubt on empirical results based on panel estimations of an 'inverted-U' relationship between per capita GDP and pollution. Using a new dataset for OECD countries on carbon dioxide emissions for the period 1960-1997, we find that the crucial assumption of homogeneity across countries is problematic. Decisively rejected are model specifications that feature even weaker homogeneity assumptions than are commonly used. Furthermore, our results challenge the existence of an overall Environmental Kuznets Curve for carbon dioxide emissions

  5. Food allergies in children: a comparison of parental reports and skin prick test results

    Camilia Metadea Aji Savitri

    2018-04-01

    Full Text Available Background Food allergy is common in children and its prevalence is generally on the rise. Imprecise parental reports about reactions to particular foods can lead to unnecessary restrictions. Since children have specific growth requirements, such nutritional restrictions may have disturbing effects on children’s growth and development. Objective To compare parental reports on food reactions to skin prick test results in their children. Method Retrospective, cross sectional study using patient’s medical record data during one-year study period. Data were analyzed manually and statistically, to assess the degree of agreement (Kappa’s coefficient and significance (P. Results We collected data from 154 subjects aged 0-18 years. For every allergen assessed, parents reported more food reactions than positive skin prick test results. Allergy incidence were caused, in order, by cow’s milk and chicken (25.3%, eggs (22.1%, chocolate (20.1%, fruits (14.3%, seafood (13%, and saltwater fish (1.9%. Kappa coefficient are all poor (0.05 except for chicken (P=0.02. Conclusion Most parents tend to overestimate which food cause reactions in their children, as reactions reported were not necessarily allergenic. Therefore, every patient experiencing allergy reactions should undergo skin prick testing to confirm the possibility of allergy.

  6. Tests of Flammability of Cotton Fabrics and Expected Skin Burns in Microgravity

    Cavanagh, Jane M.; Torvi, David A.; Gabriel, Kamiel S.; Ruff, Gary A.

    2004-01-01

    During a shuttle launch and other portions of space flight, astronauts wear specialized flame resistant clothing. However during most of their missions on board the Space Shuttle or International Space Station, astronauts wear ordinary clothing, such as cotton shirts and pants. As the behaviour of flames is considerably different in microgravity than under earth s gravity, fabrics are expected to burn in a different fashion in microgravity than when tested on earth. There is interest in determining how this change in burning behaviour may affect times to second and third degree burn of human skin, and how the results of standard fabric flammability tests conducted under earth s gravity correlate with the expected fire behaviour of textiles in microgravity. A new experimental apparatus was developed to fit into the Spacecraft Fire Safety Facility (SFSF), which is used on NASA s KC-135 low gravity aircraft. The new apparatus was designed to be similar to the apparatus used in standard vertical flammability tests of fabrics. However, rather than using a laboratory burner, the apparatus uses a hot wire system to ignite 200 mm high by 80 mm wide fabric specimens. Fabric temperatures are measured using thermocouples and/or an infrared imaging system, while flame spread rates are measured using real time observations or video. Heat flux gauges are placed between 7 and 13 mm away from the fabric specimen, so that heat fluxes from the burning fabric to the skin can be estimated, along with predicted times required to produce skin burns.

  7. MPPT algorithm test on a photovoltaic emulating system constructed by a DC power supply and an indoor solar panel

    Zhou, Z.; Holland, P.M.; Igic, P.

    2014-01-01

    Highlights: • A novel PV emulator is constructed by using conventional solar panels with a DC power supply. • The proposed PV emulator is cost-effectiveness, relatively easy implementation. • The proposed PV emulator avoids the bandwidth problem associated with electronics PV emulators. • Indoor testing of MPPT algorithms and power converters avoids the dependency on solar irradiation. • The PV emulating system has been used for testing a P and O MPPT algorithm and a boost dc converter. - Abstract: In this paper a novel photovoltaic (PV) emulating scheme for testing maximum power point tracking (MPPT) algorithms and PV inverters has been proposed. It is constructed by the parallel connection of conventional solar panels with a DC power supply operating in current source mode. The advantages of the proposed scheme are cost-effectiveness, relatively easy implementation and indoor testing of MPPT algorithms and power converters avoiding weather and time of day dependency on solar irradiation levels. Furthermore, the proposed PV emulator avoids the bandwidth problem associated with the dc converter based PV emulating systems. Detailed circuit connection, parameters, electrical characteristics and mathematical model of the PV emulator are presented and discussed. Proposed PV emulating system has been used to test a boost DC/DC converter controlled by Perturb and Observe (P and O) MPPT algorithm. Test results confirmed the effectiveness of the proposed PV emulation system and all achieved results correspond well to the original designed values

  8. Degree of skin denervation and its correlation to objective thermal sensory test in leprosy patients.

    Ismael Alves Rodrigues Júnior

    Full Text Available BACKGROUND: Leprosy is an infectious disease affecting skin and peripheral nerves resulting in increased morbidity and physical deformities. Early diagnosis provides opportune treatment and reduces its complications, relying fundamentally on the demonstration of impaired sensation in suggestive cutaneous lesions. The loss of tactile sensitivity in the lesions is preceded by the loss of thermal sensitivity, stressing the importance of the thermal test in the suspicious lesions approach. The gold-standard method for the assessment of thermal sensitivity is the quantitative sensory test (QST. Morphological study may be an alternative approach to access the thin nerve fibers responsible for thermal sensitivity transduction. The few studies reported in leprosy patients pointed out a rarefaction of thin dermo-epidermal fibers in lesions, but used semi-quantitative evaluation methods. METHODOLOGY/PRINCIPAL FINDINGS: This work aimed to study the correlation between the degree of thermal sensitivity impairment measured by QST and the degree of denervation in leprosy skin lesions, evaluated by immunohistochemistry anti-PGP 9.5 and morphometry. Twenty-two patients were included. There were significant differences in skin thermal thresholds among lesions and contralateral skin (cold, warm, cold induced pain and heat induced pain. The mean reduction in the density of intraepidermal and subepidermal fibers in lesions was 79.5% (SD = 19.6 and 80.8% (SD = 24.9, respectively. CONCLUSIONS/SIGNIFICANCE: We observed a good correlation between intraepidermal and subepidermal fibers deficit, but no correlation between these variables and those accounting for the degree of impairment in thermal thresholds, since the thin fibers rarefaction was homogeneously intense in all patients, regardless of the degree of sensory deficit. We believe that the homogeneously intense denervation in leprosy lesions should be objective of further investigations focused on its

  9. Performance of different mono- and multiplex nucleic acid amplification tests on a multipathogen external quality assessment panel.

    Loens, K; van Loon, A M; Coenjaerts, F; van Aarle, Y; Goossens, H; Wallace, P; Claas, E J C; Ieven, M

    2012-03-01

    An external quality assessment (EQA) panel consisting of a total of 48 samples in bronchoalveolar lavage (BAL) fluid or transport medium was prepared in collaboration with Quality Control for Molecular Diagnostics (QCMD) (www.qcmd.org). The panel was used to assess the proficiency of the three laboratories that would be responsible for examining the 6,000 samples to be collected in the GRACE Network of Excellence (www.grace-lrti.org). The main objective was to decide on the best-performing testing approach for the detection of influenza viruses A and B, parainfluenza virus types 1 to 3, respiratory syncytial virus (RSV), human metapneumovirus, coronavirus, rhinovirus, adenovirus, Chlamydophila pneumoniae, Mycoplasma pneumoniae, and Legionella pneumophila by nucleic acid amplification techniques (NAATs). Two approaches were chosen: (i) laboratories testing samples using their in-house procedures for extraction and amplification and (ii) laboratories using their in-house amplification procedures on centrally extracted samples. Furthermore, three commercially available multiplex NAAT tests-the ResPlex (Qiagen GmbH, Hilden, Germany), RespiFinder plus (PathoFinder, Maastricht, The Netherlands), and RespiFinder Smart 21 (PathoFinder) tests-were evaluated by examination of the same EQA panel by the manufacturer. No large differences among the 3 laboratories were noticed when the performances of the assays developed in-house in combination with the in-house extraction procedures were compared. Also, the extraction procedure (central versus local) had little effect on performance. However, large differences in amplification efficacy were found between the commercially available tests; acceptable results were obtained by using the PathoFinder assays.

  10. Development and psychometric testing of the 'Motivation and Self-Efficacy in Early Detection of Skin Lesions' index.

    Dyson, Judith; Cowdell, Fiona

    2014-12-01

    To develop and psychometrically test the Motivation and Self-Efficacy in Early Detection of Skin Lesions Index. Skin cancer is the most frequently diagnosed cancer worldwide. The primary strategy used to prevent skin cancer is promotion of sun avoidance and the use of sun protection. However, despite costly and extensive campaigns, cases of skin cancer continue to increase. If found and treated early, skin cancer is curable. Early detection is, therefore, very important. The study was conducted in 2013. Instrument Development. A literature review and a survey identified barriers (factors that hinder) and levers (factors that help) to skin self-examination. These were categorized according to a the Theoretical Domains Framework and this formed the basis of an instrument, which was tested for validity and reliability using confirmatory factor analysis and Cronbach's alpha respectively. A five-factor 20-item instrument was used that tested well for reliability and construct validity. Test-retest reliability was good for all items and domains. The five factors were: (i) Outcome expectancies; (ii) Intention; (iii) Self-efficacy; (iv) Social influences; (v) Memory. The Motivation and Self-Efficacy in Early Detection of Skin Lesions Index provides a reliable and valid method of assessing barriers and levers to skin self-examination. The next step is to design a theory-based intervention that can be tailored according to individual determinants to behaviour change identified by this instrument. © 2014 John Wiley & Sons Ltd.

  11. Analysis of the suitableness of some enzymatic tests for estimation the degree of radiational injury of skin

    Matyushichev, V.B.; Kornikov, V.V.; Taratukhin, V.R.; Timofeeva, O.E.; Vereshchagina, E.M.

    1981-01-01

    Possibilities to characterize the degree of skin injury of white male-rats on the 14th day after external 85 Kr #betta#-irradiation at 3, 4, 5, 6, 7, 8, 9, 10 krad doses by activity levels of alkali and acid DNA-ases of skin and blood plasma as well as skin and plasma alpha-amylase have been studied using the methods of factor analysis. It has been ascertained that alkali and acid DNA-ases of skin have the best indicating properties. Other tests in the main only supplement the general picture. The combined accounting of properties of alkali and acid DNA-ases of skin as well as acid DNA-ase and alpha-amylase of blood plasma permits to demarkate individuals completely according to the degree (zero - 3d) of skin injuries. These indicators can be used in practical dosimetry

  12. Design, fabrication, installation and flight service evaluation of a composite cargo ramp skin on a model CH-53 helicopter

    Lowry, D. W.; Rich, M. J.

    1983-01-01

    The installation of a composite skin panel on the cargo ramp of a CH-530 marine helicopter is discussed. The composite material is of Kevlar/Epoxy (K/E) which replaces aluminum outer skins on the aft two bays of the ramp. The cargo ramp aft region was selected as being a helicopter airframe surface subjected to possible significant field damage and would permit an evaluation of the long term durability of the composite skin panel. A structural analysis was performed and the skin shears determined. Single lap joints of K/E riveted to aluminum were statically tested. The joint tests were used to determine bearing allowables and the required K/E skin gage. The K/E skin panels riveted to aluminum edge members were tested in a shear fixture to confirm the allowable shear and bearing strengths. Impact tests were conducted on aluminum skin panels to determine energy level and damage relationship. The K/E skin panels of various ply orientations and laminate thicknesses were then impacted at similar energy levels. The results of the analysis and tests were used to determine the required K/E skin gages in each of the end two bays of the ramp.

  13. Development of an in vitro skin sensitization test based on ROS production in THP-1 cells.

    Saito, Kazutoshi; Miyazawa, Masaaki; Nukada, Yuko; Sakaguchi, Hitoshi; Nishiyama, Naohiro

    2013-03-01

    Recently, it has been reported that reactive oxygen species (ROS) produced by contact allergens can affect dendritic cell migration and contact hypersensitivity. The aim of the present study was to develop a new in vitro assay that could predict the skin sensitizing potential of chemicals by measuring ROS production in THP-1 (human monocytic leukemia cell line) cells. THP-1 cells were pre-loaded with a ROS sensitive fluorescent dye, 5-(and 6-)-chloromethyl-2', 7'-dichlorodihydrofluorescein diacetate, acetyl ester (CM-H2DCFDA), for 15min, then incubated with test chemicals for 30min. The fluorescence intensity was measured by flow cytometry. For the skin sensitizers, 25 out of 30 induced over a 2-fold ROS production at more than 90% of cell viability. In contrast, increases were only seen in 4 out of 20 non-sensitizers. The overall accuracy for the local lymph node assay (LLNA) was 82% for 50 chemicals tested. A correlation was found between the estimated concentration showing 2-fold ROS production in the ROS assay and the EC3 values (estimated concentration required to induce positive response) of the LLNA. These results indicated that the THP-1 cell-based ROS assay was a rapid and highly sensitive detection system able to predict skin sensitizing potentials and potency of chemicals. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Experimental testing and constitutive modeling of the mechanical properties of the swine skin tissue.

    Łagan, Sylwia D; Liber-Kneć, Aneta

    2017-01-01

    The aim of the study was an estimation of the possibility of using hyperelastic material models to fit experimental data obtained in the tensile test for the swine skin tissue. The uniaxial tensile tests of samples taken from the abdomen and back of a pig was carried out. The mechanical properties of the skin such as the mean Young's modulus, the mean maximum stress and the mean maximum elongation were calculated. The experimental data have been used to identify the parameters in specific strain-energy functions given in seven constitutive models of hyperelastic materials: neo-Hookean, Mooney-Rivlin, Ogden, Yeoh, Martins, Humphrey and Veronda-Westmann. An analysis of errors in fitting of theoretical and experimental data was done. Comparison of load -displacement curves for the back and abdomen regions of skin taken showed a different scope of both the mean maximum loading forces and the mean maximum elongation. Samples which have been prepared from the abdominal area had lower values of the mean maximum load compared to samples from the spine area. The reverse trend was observed during the analysis of the values of elongation. An analysis of the accuracy of model fitting to the experimental data showed that, the least accurate were the model of neo- -Hookean, model of Mooney-Rivlin for the abdominal region and model of Veronda-Westmann for the spine region. An analysis of seven hyperelastic material models showed good correlations between the experimental and the theoretical data for five models.

  15. Non-occlusive topical exposure of human skin in vitro as model for cytotoxicity testing of irritant compounds.

    Lönnqvist, Susanna; Briheim, Kristina; Kratz, Gunnar

    2016-02-01

    Testing of irritant compounds has traditionally been performed on animals and human volunteers. Animal testing should always be restricted and for skin irritancy mice and rabbits hold poor predictive value for irritant potential in humans. Irritant testing on human volunteers is restricted by the duration subjects can be exposed, and by the subjectivity of interpreting the visual signs of skin irritation. We propose an irritant testing system using viable human full thickness skin with the loss of cell viability in the exposed skin area as end point measurement. Skin was exposed to sodium dodecyl sulfate (SDS) at 20% concentration by non-occluded topical exposure to establish a positive control response and subsequent test compounds were statistically compared with the 20% SDS response. Cell viability and metabolism were measured with 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The model presents correlation between increased concentration of SDS and decreased viability of cells in the exposed skin area (R(2) = 0.76). We propose the model to be used for cytotoxicity testing of irritant compounds. With fully intact barrier function, the model comprises all cells present in the skin with quantifiable end point measurement.

  16. Radiophosphorus (32P)-test on precancerosis and malignant tumors of the skin

    Biersack, H.J.; Rodermund, O.E.; Meurin, G.; Winkler, C.; Bonn Univ.

    1976-01-01

    In 21 patients with a variety of skin tumors (squamous cell carcinomas, malignant melanomas, basal cell epitheliomas and mycosis fungoides) or precancerous lesions (Bowen's disease, actinic keratosis, junctional nevus cell nevus) the radioactive phosphorus uptake test demonstrates a sign ficantly increased concentration of P 32 in those tumors. There were no false negative tests. The possibility of differentiation of malignant melanoma from benign nevus cell nevus and the early recognition of cutaneous metastases is described. Furthermore recurrence of previously irradiated or excised basal cell epitheliomas can be detected without a biopsy. No hematological side-effects were observed. (orig.) [de

  17. A Test for Parameter Homogeneity in CO{sub 2}Panel EKC Estimations

    Dijkgraaf, E. [Erasmus University Rotterdam and SEOR, Rotterdam (Netherlands); Vollebergh, H.R.J. [Department of Economics, Erasmus University Rotterdam, PO Box 1738, 3000 DR Rotterdam (Netherlands)

    2005-10-15

    This paper casts doubt on empirical results based on panel estimations of an 'inverted-U' relationship between per capita GDP and pollution. Using a new dataset for OECD countries on carbon dioxide emissions for the period 1960-1997, we find that the crucial assumption of homogeneity across countries is problematic. Decisively rejected are model specifications that feature even weaker homogeneity assumptions than are commonly used. Furthermore, our results challenge the existence of an overall Environmental Kuznets Curve for carbon dioxide emissions.

  18. Assessment of a Protein Cocktail-Based Skin Test for Bovine Tuberculosis in a Double-Blind Field Test in Cattle

    Xin, Ting; Jia, Hong; Ding, Jiabo; Li, Pingjun; Yang, Hongjun; Hou, Shaohua; Yuan, Weifeng; Guo, Xiaoyu; Wang, Haichun; Liang, Qianqian; Li, Ming

    2013-01-01

    Bovine tuberculosis (bTB) is a worldwide zoonosis caused mainly by Mycobacterium bovis. The traditional diagnostic method used often is the tuberculin skin test, which uses bovine purified protein derivatives (PPD-B). However, it is difficult to maintain uniformity of PPD-B from batch to batch, and it shares common antigens with nonpathogenic environmental mycobacteria. To overcome these problems, M. bovis-specific antigens that showed good T cell stimulation, such as CFP-10, ESAT-6, Rv3615c, etc., have been used in the skin test, but there have been no large-scale clinical studies on these antigens. In this study, two combinations (CFP-10/ESAT-6/TB10.4 protein cocktail and CFP-10/ESAT-6/Rv3872/MPT63 protein cocktail) were developed and used as stimuli in the skin test. Cattle were double-blind tested to assess the efficiency of the protein cocktail-based skin tests. The results showed that the CFP-10/ESAT-6/TB10.4 protein cocktail-based skin test can differentiate TB-infected cattle from Mycobacterium avium-infected ones and that it shows a high degree of agreement with the traditional tuberculin skin test (κ = 0.8536) and gamma interferon (IFN-γ) release assay (κ = 0.8154). Compared to the tuberculin skin test, the relative sensitivity and relative specificity of the CFP-10/ESAT-6/TB10.4-based skin test were 87% and 97%, respectively., The relative sensitivity and relative specificity of the CFP-10/ESAT-6/TB10.4-based skin test were 93% and 92%, respectively, on comparison with the IFN-γ release assay. The correlation between the increases in skin thickness observed after the inoculation of stimuli was high (PPD-B versus CFP-10/ESAT-6/TB10.4, Spearman r of 0.8435). The correlation between the optical density at 450 nm (OD450) obtained after blood stimulation with PPD-B and the increase in skin thickness observed after inoculation of the CFP-10/ESAT-6/TB10.4 protein cocktail was high (Spearman r = 0.7335). Therefore, the CFP-10/ESAT-6/TB10.4-based skin test

  19. Skin test concentrations for systemically administered drugs -- an ENDA/EAACI Drug Allergy Interest Group position paper

    Brockow, K; Garvey, L H; Aberer, W

    2013-01-01

    Skin tests are of paramount importance for the evaluation of drug hypersensitivity reactions. Drug skin tests are often not carried out because of lack of concise information on specific test concentrations. The diagnosis of drug allergy is often based on history alone, which is an unreliable...... indicator of true hypersensitivity.To promote and standardize reproducible skin testing with safe and nonirritant drug concentrations in the clinical practice, the European Network and European Academy of Allergy and Clinical Immunology (EAACI) Interest Group on Drug Allergy has performed a literature...... search on skin test drug concentration in MEDLINE and EMBASE, reviewed and evaluated the literature in five languages using the GRADE system for quality of evidence and strength of recommendation. Where the literature is poor, we have taken into consideration the collective experience of the group...

  20. Derivation and application of mathematical model for well test analysis with variable skin factor in hydrocarbon reservoirs

    Pengcheng Liu

    2016-06-01

    Full Text Available Skin factor is often regarded as a constant in most of the mathematical model for well test analysis in oilfields, but this is only a kind of simplified treatment with the actual skin factor changeable. This paper defined the average permeability of a damaged area as a function of time by using the definition of skin factor. Therefore a relationship between a variable skin factor and time was established. The variable skin factor derived was introduced into existing traditional models rather than using a constant skin factor, then, this newly derived mathematical model for well test analysis considering variable skin factor was solved by Laplace transform. The dimensionless wellbore pressure and its derivative changed with dimensionless time were plotted with double logarithm and these plots can be used for type curve fitting. The effects of all the parameters in the expression of variable skin factor were analyzed based on the dimensionless wellbore pressure and its derivative. Finally, actual well testing data were used to fit the type curves developed which validates the applicability of the mathematical model from Sheng-2 Block, Shengli Oilfield, China.

  1. Sensitivity Comparison of the Skin Prick Test and Serum and Fecal Radio Allergosorbent Test (RAST in Diagnosis of Food Allergy in Children

    Hamid Reza Kianifar

    2016-05-01

    Full Text Available Background: Diagnosis of food allergy is difficult in children. Food allergies are diagnosed using several methods that include medical histories, clinical examinations, skin prick and serum-specific immunoglobulin E (IgE tests, radio-allergosorbent test (RAST, food challenge, and supervised elimination diets. In this study we evaluated allergies to cow's milk, egg, peanut, and fish in children with suspected food allergies with skin prick tests and serum and feces RAST. Methods: Forty-one children with clinical symptoms of food allergies were enrolled in the study. Skin prick tests and serum and fecal RAST were performed and compared with challenge tests. Results: The most common sites of food allergy symptoms were gastrointestinal (82.9% and skin (48.8%. 100% of the patients responded to the challenge tests with cow’s milk, egg, peanut, and fish. 65% of the patients tested positive with the skin prick test, 12.1% tested positive with serum RAST, and 29.2% tested positive with fecal RAST. Conclusions: The skin prick test was more sensitive than serum or fecal RAST, and fecal RAST was more than twice as sensitive as serum RAST.

  2. Antibiotic-induced immediate type hypersensitivity is a risk factor for positive allergy skin tests for neuromuscular blocking agents.

    Hagau, Natalia; Gherman, Nadia; Cocis, Mihaela; Petrisor, Cristina

    2016-01-01

    Skin tests for neuromuscular blocking agents (NMBAs) are not currently recommended for the general population undergoing general anaesthesia. In a previous study we have reported a high incidence of positive allergy tests for NMBAs in patients with a positive history of non-anaesthetic drug allergy, a larger prospective study being needed to confirm those preliminary results. The objective of this study was to compare the skin tests results for patients with a positive history of antibiotic-induced immediate type hypersensitivity reactions to those of controls without drug allergies. Ninety eight patients with previous antibiotic hypersensitivity and 72 controls were prospectively included. Skin tests were performed for atracurium, pancuronium, rocuronium, and suxamethonium. We found 65 positive skin tests from the 392 tests performed in patients with a positive history of antibiotic hypersensitivity (1 6.58%) and 23 positive skin tests from the 288 performed in controls (7.98%), the two incidences showing significant statistical difference (p = 0.0011). The relative risk for having a positive skin test for NMBAs for patients versus controls was 1.77 (1.15-2.76). For atracurium, skin tests were more often positive in patients with a positive history of antibiotic hypersensitivity versus controls (p = 0.02). For pancuronium, rocuronium and suxamethonium the statistical difference was not attained (p-values 0.08 for pancuronium, 0.23 for rocuronium, and 0.26 for suxamethonium). Patients with a positive history of antibiotic hypersensitivity seem to have a higher incidence of positive skin tests for NMBAs. They might represent a group at higher risk for developing intraoperative anaphylaxis compared to the general population. Copyright © 2015 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  3. Comparison of sensitivity of quantiferon-tb gold test and tuberculin skin test in active pulmonary tuberculosis

    Khalil, K.F.; Ambreen, A.; Butt, T.

    2013-01-01

    Objective: To compare the sensitivity of tuberculin skin test (TST) and quantiFERON-TB gold test (QFT-G) in active pulmonary tuberculosis. Study Design: Analytical study. Place and Duration of Study: Department of Pulmonology, Fauji Foundation Hospital, Rawalpindi, from July 2011 to January 2012. Methodology: QuantiFERON-TB gold test (QFT-G) was evaluated and compared it with tuberculin skin test (TST) in 50 cases of active pulmonary tuberculosis, in whom tuberculous infection was suspected on clinical, radiological and microbiological grounds. Sensitivity was determined against positive growth for Mycobacterium tuberculosis. Results: Out of 50 cases, 43 were females and 7 were males. The mean age was 41.84 A+- 19.03 years. Sensitivity of QFT-G was 80% while that of TST was 28%. Conclusion: QFT-G has much higher sensitivity than TST for active pulmonary tuberculosis. It is unaffected by prior BCG administration and prior exposure to atypical mycobacteria. A positive QFT-G result can be an adjunct to diagnosis in patients having clinical and radiological data compatible with pulmonary tuberculosis. (author)

  4. Geolocalisation of athletes for out-of-competition drug testing: ethical considerations. Position statement by the WADA Ethics Panel.

    Borry, Pascal; Caulfield, Timothy; Estivill, Xavier; Loland, Sigmund; McNamee, Michael; Knoppers, Bartha Maria

    2018-04-01

    Through the widespread availability of location-identifying devices, geolocalisation could potentially be used to place athletes during out-of-competition testing. In light of this debate, the WADA Ethics Panel formulated the following questions: (1) should WADA and/or other sponsors consider funding such geolocalisation research projects?, (2) if successful, could they be proposed to athletes as a complementary device to Anti-Doping Administration and Management System to help geolocalisation and reduce the risk of missed tests? and (3) should such devices be offered on a voluntary basis, or is it conceivable that they would be made mandatory for all athletes in registered testing pools? In this position paper, the WADA Ethics Panel concludes that the use of geolocalisation could be useful in a research setting with the goal of understanding associations between genotype, phenotype and environment; however, it recognises that the use of geolocalisation as part of or as replacement of whereabouts rules is replete with ethical concerns. While benefits remain largely hypothetical and minimal, the potential invasion of privacy and the data security threats are real. Considering the impact on privacy, data security issues, the societal ramifications of offering such services and various pragmatic considerations, the WADA Ethics Panel concludes that at this time, the use of geolocalisation should neither be mandated as a tool for disclosing whereabouts nor implemented on a voluntary basis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Contralateral prophylactic mastectomy rate and predictive factors among patients with breast cancer who underwent multigene panel testing for hereditary cancer.

    Elsayegh, Nisreen; Webster, Rachel D; Gutierrez Barrera, Angelica M; Lin, Heather; Kuerer, Henry M; Litton, Jennifer K; Bedrosian, Isabelle; Arun, Banu K

    2018-05-07

    Although multigene panel testing is increasingly common in patients with cancer, the relationship between its use among breast cancer patients with non-BRCA mutations or variants of uncertain significance (VUS) and disease management decisions has not been well described. This study evaluated the rate and predictive factors of CPM patients who underwent multigene panel testing. Three hundred and fourteen patients with breast cancer who underwent multigene panel testing between 2014 and 2017 were included in the analysis. Of the 314 patients, 70 elected CPM. Election of CPM by gene status was as follows: BRCA carriers (42.3%), non-BRCA carriers (30.1%), and VUS (10.6%). CPM election rates did not differ between non-BRCA carriers and BRCA carriers (P = 0.6205). Among non-BRCA carriers, negative hormone receptor status was associated with CPM (P = 0.0115). For those with a VUS, hormone receptor status was not associated with CPM (P = 0.1879). Although the rate of CPM between BRCA carriers and non-BRCA carriers was not significantly different, the predictors of CPM were different in each group. Our analyses shed the light on the increasing use of CPM among patients who are non-BRCA carriers as well those with a VUS. Our study elucidates the differing predictive factors of CPM election among BRCA carriers, non-BRCA carries, and those with a VUS. Our findings reveal the need for providers to be cognizant that non-BRCA genes and VUS drive women to elect CPM despite the lack of data for contralateral breast cancer risk associated with these genes. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  6. Validation of the cephalosporin intradermal skin test for predicting immediate hypersensitivity: a prospective study with drug challenge.

    Yoon, S-Y; Park, S Y; Kim, S; Lee, T; Lee, Y S; Kwon, H-S; Cho, Y S; Moon, H-B; Kim, T-B

    2013-07-01

    Cephalosporin is a major offending agent in terms of drug hypersensitivity along with penicillin. Cephalosporin intradermal skin tests (IDTs) have been widely used; however, their validity for predicting immediate hypersensitivity has not been studied. This study aimed to determine the predictive value of cephalosporin intradermal skin testing before administration of the drug. We prospectively conducted IDTs with four cephalosporins, one each of selected first-, second-, third-, or fourth-generation cephalosporins: ceftezol; cefotetan or cefamandole; ceftriaxone or cefotaxime; and flomoxef, respectively, as well as with penicillin G. After the skin test, whatever the result, one of the tested cephalosporins was administered intravenously and the patient was carefully observed. We recruited 1421 patients who required preoperative cephalosporins. Seventy-four patients (74/1421, 5.2%) were positive to at least one cephalosporin. However, none of responders had immediate hypersensitivity reactions after a challenge dose of the same or different cephalosporin, which were positive in the skin test. Four patients who suffered generalized urticaria and itching after challenge gave negative skin tests for the corresponding drug. The IDT for cephalosporin had a sensitivity of 0%, a specificity of 97.5%, a negative predictive value of 99.7%, and a positive predictive value (PPV) of 0%, when challenged with the same drugs that were positive in the skin test. Routine skin testing with a cephalosporin before its administration is not useful for predicting immediate hypersensitivity because of the extremely low sensitivity and PPV of the skin test (CRIS registration no. KCT0000455). © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of a health claim related to a combination of lycopene, vitamin E, lutein and selenium and protection of the skin from UV-induced (including photo-oxidative) damage pursuant to Article 13

    Tetens, Inge

    related to a combination of lycopene, vitamin E, lutein and selenium and protection of the skin from UV-induced (including photo-oxidative) damage. The Panel considers that the combination of lycopene, vitamin E, lutein and selenium is sufficiently characterised. The claimed effect refers to the photo...... could be drawn from this study for the scientific substantiation of the claim. The Panel concludes that a cause and effect relationship has not been established between the consumption of a combination of lycopene, vitamin E, lutein and selenium and protection of the skin from UV-induced (including......-protective activity of the food, delaying the appearance of UV-induced erythema and decreasing its intensity. The target population proposed by the applicant is healthy adults in the general population, and in particular people with sensitive skin. The Panel considers that protection of the skin from UV...

  8. The sensitization potential of sunscreen after ablative fractional skin resurfacing using modified human repeated insult patch test.

    Boonchai, Waranya; Sathaworawong, Angkana; Wongpraparut, Chanisada; Wanitphakdeedecha, Rungsima

    2015-10-01

    Ablative fractional skin resurfacing has become popular and proven to be useful in treating scars, photoaging and wrinkles. Although post-inflammatory hyperpigmentation (PIH) is the most common complication especially in dark-skinned patients like Asian. Several modalities have been used to overcome the PIH. To determine the sensitization potential of sunscreen applied immediately after ablative fractional skin resurfacing. Sixty volunteers were recruited. Of these 30 subjects were from previous ablative fractional skin resurfacing study who applied broad-spectrum sunscreen containing anti-inflammatory agent starting on the first day after resurfacing and another 30 non-resurfacing subjects had applied the same sunscreen on the intact skin. All subjects were patch/photopatch tested for sensitization study by using modified human repeated insult patch test (HRIPT). There were significantly higher sensitization rate of UV-filter, octocrylene and the sunscreen in resurfacing group than in non-resurfacing group. Early application of sunscreen after ablative fractional skin resurfacing has increased the incidence of sensitization potential of sunscreen. The sunscreen is recommended to start using from D3 after fractional ablative skin resurfacing to ensure the complete recovery of skin barrier and minimize the risk of sensitization.

  9. Compositional analysis and physicochemical and mechanical testing of tanned rabbit skins

    M.L. R. Sousa

    2016-09-01

    Full Text Available Chemical composition and physicochemical and mechanical parameters of New Zealand White rabbit tanned skin were evaluated. Skin samples from 70-d-old males, in natura and semi-finished, were collected for evaluation. The in natura treatment comprise skins without any processing, while semi-finished treatment comprise skins after soaking, fleshing, liming, de-liming, purging, degreasing, pickling, tanning, neutralising, re-tanning and dyeing, followed by oiling, drying, stretching and softening. After tanning, samples from the dorsal and flank regions were removed for tensile and physicochemical testing in the longitudinal and transverse directions. A split plot design was used with plot treatments (leather regions: R1=dorsal and R2=flank and subplots directions (S1=longitudinal and S2=transversal, using 10 examples per treatment. At the end of processing, the leather analysis revealed low moisture (31.76%, protein (46.48% and fat content (24.95%, and a high ash content (8.58%. Leather presented a pH of 4.9 and contained 2.0% chromium oxide, 25.5% extractable substances in dichloromethane, and these characteristics were coupled with a higher tensile strength (10.84 N/mm2 in the dorsal region. However, samples in the same region proved to have higher elasticity (64.57% in the longitudinal direction, although there was no difference in the progressive tearing analysis (21.07-23.50 N/mm. Overall, our analyses suggest that, in this case, the tanned leather product does not have sufficient resistance for application in clothing production.

  10. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion.

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-09-02

    Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Design and commission of an experimental test rig to apply a full-scale pressure load on composite sandwich panels representative of an aircraft secondary structure

    Crump, D A; Dulieu-Barton, J M; Savage, J

    2010-01-01

    This paper describes the design of a test rig, which is used to apply a representative pressure load to a full-scale composite sandwich secondary aircraft structure. A generic panel was designed with features to represent those in the composite sandwich secondary aircraft structure. To provide full-field strain data from the panels, the test rig was designed for use with optical measurement techniques such as thermoelastic stress analysis (TSA) and digital image correlation (DIC). TSA requires a cyclic load to be applied to a structure for the measurement of the strain state; therefore, the test rig has been designed to be mounted on a standard servo-hydraulic test machine. As both TSA and DIC require an uninterrupted view of the surface of the test panel, an important consideration in the design is facilitating the optical access for the two techniques. To aid the test rig design a finite element (FE) model was produced. The model provides information on the deflections that must be accommodated by the test rig, and ensures that the stress and strain levels developed in the panel when loaded in the test rig would be sufficient for measurement using TSA and DIC. Finally, initial tests using the test rig have shown it to be capable of achieving the required pressure and maintaining a cyclic load. It was also demonstrated that both TSA and DIC data can be collected from the panels under load, which are used to validate the stress and deflection derived from the FE model

  12. Buckling Testing and Analysis of Honeycomb Sandwich Panel Arc Segments of a Full-Scale Fairing Barrel. Part 3; 8-ply Out-of-Autoclave Facesheets

    Pineda, Evan J.; Myers, David E.; Kosareo, Daniel N.; Kellas, Sotiris

    2014-01-01

    Four honeycomb sandwich panels, representing 1/16th arc segments of a 10 m diameter barrel section of the heavy lift launch vehicle, were manufactured under the NASA Composites for Exploration program and the NASA Constellation Ares V program. Two configurations were chosen for the panels: 6-ply facesheets with 1.125 in. honeycomb core and 8-ply facesheets with 1.000 in. honeycomb core. Additionally, two separate carbon fiber/epoxy material systems were chosen for the facesheets: inautoclave IM7/977-3 and out-of-autoclave T40-800B/5320-1. Smaller 3- by 5-ft panels were cut from the 1/16th barrel sections. These panels were tested under compressive loading at the NASA Langley Research Center. Furthermore, linear eigenvalue and geometrically nonlinear finite element analyses were performed to predict the compressive response of the 3- by 5-ft panels. This manuscript summarizes the experimental and analytical modeling efforts pertaining to the panel composed of 8-ply, T40-800B/5320-1 facesheets (referred to as Panel C). To improve the robustness of the geometrically nonlinear finite element model, measured surface imperfections were included in the geometry of the model. Both the linear and nonlinear, two-dimensional (2-D) and three-dimensional (3-D), models yield good qualitative and quantitative predictions. Additionally, it was predicted correctly that the panel would fail in buckling prior to failing in strength.

  13. Summarized results of the cryosorption panel test programme for the ITER cryopumping system

    Day, C.; Haas, H.; Mack, A.; Kazakovsky, N.T.; Murdoch, D.K.; Roehrig, D.; Saksagansky, G.L.

    2001-01-01

    A reliable but versatile primary cryopumping system is required for high vacuum pumping of the ITER torus during all phases of plasma operation. To achieve that goal, an extensive R and D programme has been performed within the framework of the Nuclear Fusion Project of FZK, supported by the European Communities under the European Fusion Technology Programme. The present paper covers that part of the programme, which focuses on the pumping speed of the recommended cryopanel type and the various aspects of the charcoal-bonding system in the cryogenic temperature range. It is demonstrated that the investigated cryosorption panels exhibit a very good behaviour with respect to pumping efficiency, long-term thermomechanical endurance and compatibility with tritium. The recommended cryopump design was therefore chosen as point design for ITER. (author)

  14. Opisthorchis felineus negatively associates with skin test reactivity in Russia-EuroPrevall-International Cooperation study.

    Fedorova, O S; Janse, J J; Ogorodova, L M; Fedotova, M M; Achterberg, R A; Verweij, J J; Fernández-Rivas, M; Versteeg, S A; Potts, J; Minelli, C; van Ree, R; Burney, P; Yazdanbakhsh, M

    2017-07-01

    Most studies on the relationship between helminth infections and atopic disorders have been conducted in (sub)tropical developing countries where exposure to multiple parasites and lifestyle can confound the relationship. We aimed to study the relationship between infection with the fish-borne helminth Opishorchis felineus and specific IgE, skin prick testing, and atopic symptoms in Western Siberia, with lifestyle and hygiene standards of a developed country. Schoolchildren aged 7-11 years were sampled from one urban and two rural regions. Skin prick tests (SPT) and specific IgE (sIgE) against food and aeroallergens were measured, and data on allergic symptoms and on demographic and socioeconomic factors were collected by questionnaire. Diagnosis of opisthorchiasis was based on PCR performed on stool samples. Of the 732 children included, 34.9% had opisthorchiasis. The sensitization to any allergen when estimated by positive SPT was 12.8%, while much higher, 24.0%, when measured by sIgE. Atopic symptoms in the past year (flexural eczema and/or rhinoconjunctivitis) were reported in 12.4% of the children. SPT was positively related to flexural eczema and rhinoconjunctivitis, but not to wheezing. Opisthorchiasis showed association with lower SPT response, as well as borderline association with low IgE reactivity to any allergen. However, the effect of opisthorchiasis on SPT response was not mediated by IgE, suggesting that opisthorchiasis influences SPT response through another mechanism. Opisthorchiasis also showed borderline association with lower atopic symptoms. There is a negative association between a chronic helminth infection and skin prick test reactivity even in a developed country. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. The prevalence of skin-test-positive allergic rhinitis in Danish adults

    Linneberg, A; Jørgensen, T; Nielsen, N H

    2000-01-01

    BACKGROUND: It is disputed whether increases in self-reported respiratory allergy represent a true increase or merely increased recognition. We aimed to investigate whether the prevalence of skin-prick-test (SPT)-positive allergic rhinitis had increased in an adult general population in Copenhagen...... (participation rate 74.6%) and 482 (participation rate 53.4%) subjects were examined in 1990 and 1998, respectively. Diagnoses of SPT-positive allergic rhinitis were based on a history of nasal symptoms on exposure to allergens and SPT positivity to allergens. RESULTS: The prevalence of a diagnosis of SPT...

  16. Testing Human Skin and Respiratory Sensitizers—What Is Good Enough?

    Anki Malmborg

    2017-01-01

    Full Text Available Alternative methods for accurate in vitro assessment of skin and respiratory sensitizers are urgently needed. Sensitization is a complex biological process that cannot be evaluated accurately using single events or biomarkers, since the information content is too restricted in these measurements. On the contrary, if the tremendous information content harbored in DNA/mRNA could be mined, most complex biological processes could be elucidated. Genomic technologies available today, including transcriptional profiling and next generation sequencing, have the power to decipher sensitization, when used in the right context. Thus, a genomic test platform has been developed, denoted the Genomic Allergen Rapid Detection (GARD assay. Due to the high informational content of the GARD test, accurate predictions of both the skin and respiratory sensitizing capacity of chemicals, have been demonstrated. Based on a matured dendritic cell line, acting as a human-like reporter system, information about potency has also been acquired. Consequently, multiparametric diagnostic technologies are disruptive test principles that can change the way in which the next generation of alternative methods are designed.

  17. Identification of common allergens for united airway disease by skin prick test

    Vikas Deep Mishra

    2016-01-01

    Full Text Available Objective: Identification of common allergens by skin prick test in patients of united airway disease. Materials and Methods: Skin prick test was performed in 60 patients of United Airway Disease to identify the common allergens. A total of 62 allergens consisting of 36 types of pollen, 5 fungi, 4 insects, 8 type of dusts, 4 dander, 3 fabrics, Dust mite and Parthenium leaves were tested. Result: Most common allergens were Dust mite (60% followed by Parthenium leaves (45%, insects (18.75%, pollen (14.81%, dust allergens (8.51%, fabrics (8.33%, fungi (5.66%, dander (5%. Most common insect allergens were cockroach (female (30%, cockroach (male (23.33%. Common pollens were Ricinus communis (28.33%, Amaranthus spinosus (28.33%, Parthenium hysterophorus (26.66%, Eucalyptus tereticornis (26.66% and Cynodon dactylon (25%. Common dust allergens were house dust (21.66%, paper dust (11.66% and cotton mill dust (10%. Among fabrics kapok cotton (13.33% showed maximum positivity. Among fungi Aspergillus fumigatus (10% followed by A. niger (6.66% were most common. In animal dander group common ones were cat dander followed by dog dander. Conclusion: In conclusion it can be said that the knowledge drawn by above study will help to treat patients by immunotherapy or avoidance strategy.

  18. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy

    Tannert, Line Kring; Mørtz, Charlotte G; Skov, Per Stahl

    2017-01-01

    INTRODUCTION: According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. OBJECTIVE: To investigate the clinical relevance...... of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. METHODS: A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged......-IgE measured (T0), and then skin tested and had s-IgE measured 4 weeks later (T1). RESULTS: Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T0. Positive ST result or positive s-IgE alone did not predict...

  19. Association of Short-Term Exposure to Ambient Fine Particulate Matter with Skin Symptoms in Schoolchildren: A Panel Study in a Rural Area of Western Japan

    Masanari Watanabe

    2017-03-01

    Full Text Available Numerous studies have unmasked the deleterious effects of particulate matter less than 2.5 μm (PM2.5 on health. However, epidemiologic evidence focusing on the effects of PM2.5 on skin health remains limited. An important aspect of Asian dust (AD in relationship to health is the amount of PM2.5 contained therein. Several studies have demonstrated that AD can aggravate skin symptoms. The current study aimed to investigate the effects of short-term exposure to PM2.5 and AD particles on skin symptoms in schoolchildren. A total of 339 children recorded daily skin symptom scores during February 2015. Light detection and ranging were used to calculate AD particle size. Generalized estimating equation logistic regression analyses were used to estimate the associations among skin symptoms and the daily levels of PM2.5 and AD particles. Increases in the levels of PM2.5 and AD particles were not related to an increased risk of skin symptom events, with increases of 10.1 μg/m3 in PM2.5 and 0.01 km−1 in AD particles changing odds ratios by 1.03 and 0.99, respectively. These results suggest that short-term exposure to PM2.5 and AD does not impact skin symptoms in schoolchildren.

  20. 78 FR 68076 - Request for Information on Alternative Skin Sensitization Test Methods and Testing Strategies and...

    2013-11-13

    ... Laboratory for Alternatives to Animal Testing (EURL ECVAM), and by the industry organization Cosmetics Europe... products. Pesticides and other marketed chemicals, including cosmetic ingredients, are routinely tested for... sensitization. NICEATM collaboration with industry scientists to develop an open-source Bayesian network as an...

  1. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng

    2014-01-01

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers

  2. Instrumental intelligent test of food sensory quality as mimic of human panel test combining multiple cross-perception sensors and data fusion

    Ouyang, Qin; Zhao, Jiewen; Chen, Quansheng, E-mail: qschen@ujs.edu.cn

    2014-09-02

    Highlights: • To develop a novel instrumental intelligent test methodology for food sensory analysis. • A novel data fusion was used in instrumental intelligent test methodology. • Linear and nonlinear tools were comparatively used for modeling. • The instrumental test methodology can be imitative of human test behavior. - Abstract: Instrumental test of food quality using perception sensors instead of human panel test is attracting massive attention recently. A novel cross-perception multi-sensors data fusion imitating multiple mammal perception was proposed for the instrumental test in this work. First, three mimic sensors of electronic eye, electronic nose and electronic tongue were used in sequence for data acquisition of rice wine samples. Then all data from the three different sensors were preprocessed and merged. Next, three cross-perception variables i.e., color, aroma and taste, were constructed using principal components analysis (PCA) and multiple linear regression (MLR) which were used as the input of models. MLR, back-propagation artificial neural network (BPANN) and support vector machine (SVM) were comparatively used for modeling, and the instrumental test was achieved for the comprehensive quality of samples. Results showed the proposed cross-perception multi-sensors data fusion presented obvious superiority to the traditional data fusion methodologies, also achieved a high correlation coefficient (>90%) with the human panel test results. This work demonstrated that the instrumental test based on the cross-perception multi-sensors data fusion can actually mimic the human test behavior, therefore is of great significance to ensure the quality of products and decrease the loss of the manufacturers.

  3. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of a health claim related to flaxseed oil and vitamin E and maintenance of the skin permeability barrier function pursuant to Article 13(5) of Regulation (EC) No 1924/2006

    Tetens, Inge

    related to a combination of flaxseed oil and vitamin E and maintenance of the skin permeability barrier function. The food constituent that is the subject of the health claim is a combination of flaxseed oil and vitamin E. The Panel considers that the combination of flaxseed oil and vitamin E...... be drawn from these studies for the scientific substantiation of the claim. The Panel concludes that a cause and effect relationship has not been established between the consumption of a combination of flaxseed oil and vitamin E and maintenance of the skin permeability barrier function...... is sufficiently characterised. The claimed effect is “contributes to maintain skin permeability barrier function”. The target population proposed by the applicant is healthy adults with dry and sensitive skin. Maintenance of the permeability barrier function of the skin is a beneficial physiological effect...

  4. Concordant or discordant results by the tuberculin skin test and the quantiFERON-TB test in children reflect immune biomarker profiles

    Dhanasekaran, S; Jenum, S; Stavrum, R

    2014-01-01

    The tuberculin skin test (TST) and QuantiFERON-TB-Gold-In-tube (QFTGIT) are adjunctive tests used in the diagnosis of pediatric tuberculosis (TB). Neither test can rule out TB; however, a positive test usually triggers preventive treatment in TB contacts aged <5 years. TST and QFTGIT can give div...

  5. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  6. Panel development for multicolor flow-cytometry testing of proliferation and immunophenotype in hMSCs.

    Bradford, Jolene A; Clarke, Scott T

    2011-01-01

    Adult human mesenchymal stem cells (hMSC) are rare fibroblast-like cells capable of differentiation into a variety of cell tissues which include bone, cartilage, muscle, ligament, tendon, and adipose. Normal adult bone marrow and adipose tissue are the most common sources of these cells. The International Society for Cellular Therapy (ISCT) has proposed a set of standards to define hMSC for laboratory investigations and preclinical studies: adherence to plastic in standard culture conditions; in vitro differentiation into osteoblasts, adipocytes, and chondroblasts; and specific surface antigen expression. Direct measurement of proliferation combined with simultaneous detection of the ISCT-consensus immunophenotypic profile provides data that is used to determine the differentiation status and health of the cells. Flow cytometry provides a powerful technology that is routinely used to simultaneously and rapidly measure multiple parameters in a single sample. This chapter describes a flow cytometric panel for the simultaneous detection of immunophenotypic profile, proliferative capacity, and DNA content measurement in hMSC. Because a relatively small number of cells are needed with this approach, measurements can be made with minimal impact on expansion potential. The ability to assess antigen expression and proliferative status enables the investigator to make informed decisions on expansion and harvesting.

  7. Association between parasitic infections and tuberculin skin test results in refugees.

    Watts, Nathaniel S; Mizinduko, Mucho M; Barnett, Elizabeth D; White, Laura F; Hochberg, Natasha S

    Parasitic infections are known to modulate the immune response necessary for controlling Mycobacterium tuberculosis infection. We sought to investigate species-specific effects of parasite infection on M. tuberculosis infection. As part of the Refugee Health Assessment Program, stool examinations and tuberculin skin testing were performed on refugees seen at Boston Medical Center between 1995 and 2012. Tuberculin skin test (TST) and stool examination data were collected for 6669 refugees; 3349 (50.2%) were TST positive (≥10 mm). Among TST-positive subjects, 176 (5.3%) had helminth infections and 1149 (34.3%) protozoa. After adjusting for sex, age, and country of origin, helminth and protozoan infections were not associated with TST-positivity. When species-specific effects were examined, subjects infected with Trichuris trichiura and Giardia lamblia had reduced odds of TST-positivity (adjusted OR [aOR] 0.65 [95%CI 0.44-0.96; p = 0.03] and aOR 0.79 [95%CI 0.65-0.95, p = 0.01], respectively). Our findings suggest that T. trichiura and G. lamblia may provide protection against M. tuberculosis infection. This study adds to a growing body of literature suggesting that immune response modulation and susceptibility to M. tuberculosis infection is parasite species-dependent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. GALEN skin test study III: Minimum battery of test inhalent allergens needed in epidemiological studies in patients

    Bousquet, P-J; Burbach, G; Heinzerling, L M

    2009-01-01

    Background: The number of allergens to be tested in order to identify sensitized patients is important in order to have the most cost-effective approach in epidemiological studies. Objective: To define the minimal number and the type of skin prick test (SPT) allergens required to identify a patient...... the allergens selection. Result: Among the 3034 patients involved, 1996 (68.2%) were sensitized to at least one allergen. Overall, eight allergens (grass pollen, Dermatophagoides pteronyssinus, birch pollen, cat dander, Artemisia, olive pollen, Blatella and Alternaria) allowed to identified more than 95......% of sensitized subjects. However, differences were observed between countries, two allergens being sufficient for Switzerland (grass pollen and cat dander) as opposed to nine for France (grass pollen, Dermatophagoides pteronyssinus, olive pollen, cat dander, Blatella, cypress, dog dander, alder and [Artemisia...

  9. Intraoperative anaphylaxis to sugammadex and a protocol for intradermal skin testing.

    Sadleir, P H M; Russell, T; Clarke, R C; Maycock, E; Platt, P R

    2014-01-01

    Sugammadex is a selective binding agent for aminosteroid neuromuscular blockers whose use is increasing in anaesthetic practice. We present three cases of severe anaphylaxis coincident with sugammadex administration. Subsequent intradermal testing confirmed sugammadex as the triggering agent, with all patients having positive skin responses to a 1:100 dilution of the standard 100 mg/ml solution and two out of three having a positive response to a 1:1000 dilution. As all patients were administered sugammadex to reverse neuromuscular blockade with rocuronium, we considered that sugammadex-rocuronium complexes were a potential unique allergen. In the two patients who were additionally tested with a rocuronium-sugammadex (3.6:1 molecular ratio) mixture, the wheal-and-flare response was significantly attenuated.

  10. Skin sensitisation: the Colipa strategy for developing and evaluating non-animal test methods for risk assessment.

    Maxwell, Gavin; Aeby, Pierre; Ashikaga, Takao; Bessou-Touya, Sandrine; Diembeck, Walter; Gerberick, Frank; Kern, Petra; Marrec-Fairley, Monique; Ovigne, Jean-Marc; Sakaguchi, Hitoshi; Schroeder, Klaus; Tailhardat, Magali; Teissier, Silvia; Winkler, Petra

    2011-01-01

    Allergic contact dermatitis is a delayed-type hypersensitivity reaction induced by small reactive chemicals (haptens). Currently, the sensitising potential and potency of new chemicals is usually characterised using data generated via animal studies, such as the local lymph node assay (LLNA). There are, however, increasing public and political concerns regarding the use of animals for the testing of new chemicals. Consequently, the development of in vitro, in chemico or in silico models for predicting the sensitising potential and/or potency of new chemicals is receiving widespread interest. The Colipa Skin Tolerance task force currently collaborates with and/or funds several academic research groups to expand our understanding of the molecular and cellular events occurring during the acquisition of skin sensitisation. Knowledge gained from this research is being used to support the development and evaluation of novel alternative approaches for the identification and characterisation of skin sensitizing chemicals. At present three non-animal test methods (Direct Peptide Reactivity Assay (DPRA), Myeloid U937 Skin Sensitisation Test (MUSST) and human Cell Line Activation Test (hCLAT)) have been evaluated in Colipa interlaboratory ring trials for their potential to predict skin sensitisation potential and were recently submitted to ECVAM for formal pre-validation. Data from all three test methods will now be used to support the study and development of testing strategy approaches for skin sensitiser potency prediction. This publication represents the current viewpoint of the cosmetics industry on the feasibility of replacing the need for animal test data for informing skin sensitisation risk assessment decisions.

  11. Laser heat stimulation of tiny skin areas adds valuable information to quantitative sensory testing in postherpetic neuralgia.

    Franz, Marcel; Spohn, Dorothee; Ritter, Alexander; Rolke, Roman; Miltner, Wolfgang H R; Weiss, Thomas

    2012-08-01

    Patients suffering from postherpetic neuralgia often complain about hypo- or hypersensation in the affected dermatome. The loss of thermal sensitivity has been demonstrated by quantitative sensory testing as being associated with small-fiber (Aδ- and C-fiber) deafferentation. We aimed to compare laser stimulation (radiant heat) to thermode stimulation (contact heat) with regard to their sensitivity and specificity to detect thermal sensory deficits related to small-fiber dysfunction in postherpetic neuralgia. We contrasted detection rate of laser stimuli with 5 thermal parameters (thresholds of cold/warm detection, cold/heat pain, and sensory limen) of quantitative sensory testing. Sixteen patients diagnosed with unilateral postherpetic neuralgia and 16 age- and gender-matched healthy control subjects were tested. Quantitative sensory testing and laser stimulation of tiny skin areas were performed in the neuralgia-affected skin and in the contralateral homologue of the neuralgia-free body side. Across the 5 thermal parameters of thermode stimulation, only one parameter (warm detection threshold) revealed sensory abnormalities (thermal hypoesthesia to warm stimuli) in the neuralgia-affected skin area of patients but not in the contralateral area, as compared to the control group. In contrast, patients perceived significantly less laser stimuli both in the affected skin and in the contralateral skin compared to controls. Overall, laser stimulation proved more sensitive and specific in detecting thermal sensory abnormalities in the neuralgia-affected skin, as well as in the control skin, than any single thermal parameter of thermode stimulation. Thus, laser stimulation of tiny skin areas might be a useful diagnostic tool for small-fiber dysfunction. Copyright © 2012 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  12. Puncture panel optimization

    Glass, R.E.; Longenbaugh, R.S.

    1986-01-01

    Sandia National Laboratories developed the TRansUranic PACkage Transporter (TRUPACT) to transport defense contact-handled transuranic wastes. The package has been designed to meet the normal and hypothetical accident conditions in 10CFR71 which includes the demonstrated ability to survive a 1-meter drop onto a mild steel pin. The puncture protection is provided by puncture resistant panels. In conjunction with the development of TRUPACT, a series of experiments has been conducted to reduce the weight of the puncture resistant panels. The initial scoping tests resulted in a preliminary design incorporating 30 layers of Kevlar. This design has been shown to meet the regulatory puncture test. To reduce the weight of this panel, subscale tests were conducted on panels utilizing Kevlar yarns with varying mass per unit length (denier) as well as different resins. This paper reviews the testing undertaken in the original panel development and discusses the results obtained from the recent subscale and full-scale optimization tests

  13. Composite panel development at JPL

    Mcelroy, Paul; Helms, Rich

    1988-01-01

    Parametric computer studies can be use in a cost effective manner to determine optimized composite mirror panel designs. An InterDisciplinary computer Model (IDM) was created to aid in the development of high precision reflector panels for LDR. The materials properties, thermal responses, structural geometries, and radio/optical precision are synergistically analyzed for specific panel designs. Promising panels designs are fabricated and tested so that comparison with panel test results can be used to verify performance prediction models and accommodate design refinement. The iterative approach of computer design and model refinement with performance testing and materials optimization has shown good results for LDR panels.

  14. Novel Field test design and initial result for AC and DC characterization for PV-panels

    Thorsteinsson, Sune; Riedel, Nicholas; Santamaria Lancia, Adrian Alejo

    This work describes the design and initial test results of a field test for PV modules, where the PV modules the majority of the time operates to produce power at their maximum power point. Sequentially the individual modules are switched into a measurement circuitry for IV curves and impedance s...

  15. Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.

    Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk

    2013-06-01

    The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Testes cutâneos de hipersensibilidade imediata com o evoluir da idade Positive skin test and age

    Wilma Carvalho Neves Forte

    2001-04-01

    Full Text Available OBJETIVO: avaliação da positividade aos testes cutâneos de hipersensibilidade imediata em crianças com asma brônquica e/ou rinite alérgica em diferentes faixas etárias. CASUÍSTICA E MÉTODOS: foi observada a positividade aos testes cutâneos de hipersensibilidade imediata, por testes de puntura, frente a diferentes alérgenos de mesma procedência: poeira total e Dermatophagóides sp, Dermatophagoides pteronyssinus, Dermatophagoides farinae e Blomia tropicalis, Penicillium sp, Alternaria alternata, Cladosporium herbarium, Aspergillus fumigatus, grama bermuda, capim de pasto, epitélio de cão, epitélio de gato, penas, Blatella germanica, lã. Foram selecionadas 713 crianças divididas em grupos conforme a faixa etária: grupo I (6 a 11 meses, II (1 a 3 anos e 11 meses, III (4 a 8 anos e 11 meses e IV (9 a 15 anos. Para análise estatística utilizou-se o cálculo do qui-quadrado. RESULTADOS: o total de diferenças significativas entre os vários grupos foi: I e II = 5; II e III = 5; II e IV = 5; III e IV = 6; I e III = 10 e I e IV = 10 CONCLUSÃO: concluiu-se que a positividade ao teste de hipersensibilidade imediata foi maior com o evoluir da idade, havendo positividade já aos doze meses de vida, sendo esta positividade significativamente maior a partir de quatro anos de idade.OBJECTIVE: to evaluate positive responses to skin tests for immediate hypersensitivity to allergens in children with asthma and rhinitis at different ages. METHOD: we observed positive skin test reactivity in prick tests using fifteen allergens of same origin (total dust and Dermatophagoides sp.; Dermatophagoides pteronyssinus; Dermatophagoides farinae; Blomia tropicalis; Penicillium sp; Alternaria alternata; Cladosporium herbarium; Aspergillus fumigatus; Bermuda grass; forage grass; dog and cat epithelia; feathers; Blatella germanica and wool. We placed 713 selected patients into different age groups - Group I: 6 to 11 months; Group II: 1 to 3 years and 11

  17. Development and preliminary testing of a standardized method for quantifying excess water in over-hydrated skin using evaporimetry

    Fader, M; Clark-O'Neill, S R; Cottenden, A M; Wong, W K R; Runeman, B; Farbrot, A

    2011-01-01

    Although evaporimetry (the measurement of water vapour flux density from the skin) has often been used to study the impact on skin hydration of using products such as baby diapers and incontinence pads, it is difficult to interpret results and to compare data from different studies because of the diversity of unvalidated methodologies used. The aim of this work was to develop a robust methodology for measuring the excess water in over-hydrated skin and test it on volar forearm and hip skin which had been occluded with saline soaked patches. Three repeat measurements were made on the volar forearm and the hip of five young (31–44 years) and six older (67–85 years) women and moderately good within-subject repeatability was found for both skin sites for both subject groups. Measurements taken from the hip were significantly higher (P = 0.001) than those from the arm and had larger coefficients of variation (3.5–22.1%) compared to arms (3.0–14.0%). There were no significant differences between young and older skin, implying that women for future studies could be recruited without regard to age. This is the first time that a robust evaporimetric methodology for quantifying excess water in over-hydrated skin has been described and validated, and it will form a solid basis for future work

  18. Effects of different base agents on prediction of skin irritation by sodium lauryl sulfate using patch testing and repeated application test.

    Horita, Kotomi; Horita, Daisuke; Tomita, Hiroyuki; Yasoshima, Mitsue; Yagami, Akiko; Matsunaga, Kayoko

    2017-05-01

    Animal testing for cosmetics was banned in the European Union (EU) in 2013; therefore, human tests to predict and ensure skin safety such as the patch test or usage test are now in demand in Japan as well as in the EU. In order to investigate the effects of different bases on the findings of tests to predict skin irritation, we performed patch testing (PT) and the repeated application test (RAT) using sodium lauryl sulfate (SLS), a well-known irritant, dissolved in 6 different base agents to examine the effects of these bases on skin irritation by SLS. The bases for PT were distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream. The concentrations of SLS were 0.2% and 0.5%. Twelve different base combinations were applied to the normal back skin of 19 individuals for 24h. RAT was performed with distilled water, 50% ethanol, 100% ethanol, a gel containing 50% ethanol, white petrolatum, and hydrophilic cream containing SLS at concentrations of 0.2%, 2%, and 5%, being applied to the arms of the same PT subjects. The test preparation of each base was applied at the same site, with 0.2% SLS being used in the first week, 2% SLS in the following week, and 5% SLS in the final week. The results of PT revealed that skin irritation scores varied when SLS at the same concentration was dissolved in a different base. The results of RAT showed that although skin irritation appeared with every base at a concentration of 5%, the positive rate was approximately the same. In conclusion, our results suggest that skin irritation elicited in PT depends on the base, while in RAT, it does not depend on the type of base employed. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Buckling Testing and Analysis of Honeycomb Sandwich Panel Arc Segments of a Full-Scale Fairing Barrel: Comparison of In- and Out-of-Autoclave Facesheet Configurations

    Pineda, Evan Jorge; Myers, David E.; Kosareo, Daniel N.; Zalewski, Bart F.; Kellas, Sotiris; Dixon, Genevieve D.; Krivanek, Thomas M.; Gyekenyesi, Thomas G.

    2014-01-01

    Four honeycomb sandwich panels, representing 1/16th arc segments of a 10-m diameter barrel section of the Heavy Lift Launch Vehicle, were manufactured and tested under the NASA Composites for Exploration and the NASA Constellation Ares V programs. Two configurations were chosen for the panels: 6-ply facesheets with 1.125 in. honeycomb core and 8-ply facesheets with 1.0 in. honeycomb core. Additionally, two separate carbon fiber/epoxy material systems were chosen for the facesheets: in-autoclave IM7/977-3 and out-of-autoclave T40-800b/5320-1. Smaller 3 ft. by 5 ft. panels were cut from the 1/16th barrel sections and tested under compressive loading. Furthermore, linear eigenvalue and geometrically nonlinear finite element analyses were performed to predict the compressive response of each 3 ft. by 5 ft. panel. To improve the robustness of the geometrically nonlinear finite element model, measured surface imperfections were included in the geometry of the model. Both the linear and nonlinear models yielded good qualitative and quantitative predictions. Additionally, it was correctly predicted that the panel would fail in buckling prior to failing in strength. Furthermore, several imperfection studies were performed to investigate the influence of geometric imperfections, fiber angle misalignments, and three-dimensional effects on the compressive response of the panel.

  20. Histamine 50-skin-prick test: a tool to diagnose histamine intolerance.

    Kofler, Lukas; Ulmer, Hanno; Kofler, Heinz

    2011-01-01

    Background. Histamine intolerance results from an imbalance between histamine intake and degradation. In healthy persons, dietary histamine can be sufficiently metabolized by amine oxidases, whereas persons with low amine oxidase activity are at risk of histamine toxicity. Diamine oxidase (DAO) is the key enzyme in degradation. Histamine elicits a wide range of effects. Histamine intolerance displays symptoms, such as rhinitis, headache, gastrointestinal symptoms, palpitations, urticaria and pruritus. Objective. Diagnosis of histamine intolerance until now is based on case history; neither a validated questionnaire nor a routine test is available. It was the aim of this trial to evaluate the usefullness of a prick-test for the diagnosis of histamine intolerance. Methods. Prick-testing with 1% histamine solution and wheal size-measurement to assess the relation between the wheal in prick-test, read after 20 to 50 minutes, as sign of slowed histamine degradation as well as history and symptoms of histamine intolerance. Results. Besides a pretest with 17 patients with HIT we investigated 156 persons (81 with HIT, 75 controls): 64 out of 81 with histamine intolerance(HIT), but only 14 out of 75 persons from the control-group presented with a histamine wheal ≥3 mm after 50 minutes (P < .0001). Conclusion and Clinical Relevance. Histamine-50 skin-prickt-test offers a simple tool with relevance.

  1. Autoimmune liver disease panel

    Liver disease test panel - autoimmune ... Autoimmune disorders are a possible cause of liver disease. The most common of these diseases are autoimmune hepatitis and primary biliary cholangitis (formerly called primary biliary cirrhosis). This group of tests ...

  2. The incidence and features of systemic reactions to skin prick tests.

    Sellaturay, Priya; Nasser, Shuaib; Ewan, Pamela

    2015-09-01

    Skin prick testing (SPT) has been regarded as a safe procedure with few systemic reactions. To evaluate the rate of systemic reactions and their associations after SPT in the largest population to date. In this study reactions were recorded prospectively in a specialist UK allergy clinic for 6 years (2007-2013). An estimated 31,000 patients underwent SPT. Twenty-four patients (age range 7 months to 56 years, mean 23.5 years, 17 female patients, 12 with asthma) had systemic reactions. The rate of systemic reactions to SPT was 0.077%. The likely allergens causing the reaction were foods (18; peanut, 7; walnut, 1; Brazil nut, 2; pistachio, 1; lupin, 1; cow's milk, 2; shrimp, 1; spinach, 1; legume, 1; soy, 1), aeroallergens (4; rabbit, 1; rat, 1; ragwort, 1; grass pollen, 1), wasp venom (1), and Tazocin (1). The causative SPT wheal was larger than 8 mm in 75%. The reaction to Tazocin was severe, with anaphylaxis occurring minutes after SPT. Reactions were treated immediately in the clinic and did not require further medical care. In this largest single-center study, the rate of systemic reactions after SPT was 77 per 100,000 patients. It is the first study to identify foods as a common and important cause (75%), with nuts posing the highest risk. This study reports the first systemic reaction to venom SPT and the first anaphylactic reaction after drug SPT. There was an association with a history of severe reactions and large skin test reaction. There are risks, albeit small, when undertaking SPT. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. The Tritiated Water Skin Barrier Integrity Test: Considerations for Acceptance Criteria with and Without 14C-Octanol.

    Lehman, Paul A; Beatch, Kacie; Raney, Sam G; Franz, Thomas J

    2017-01-01

    A study was designed to assess barrier integrity simultaneously using separate compounds (probes) for polar and non-polar pathways through the skin, 3 H 2 O and 14 C-octanol, respectively; and to determine whether the two probe approach could better define barrier integrity. A 5-min dose of water containing 3 H 2 O and 14 C -octanol was applied to ex vivo human skin mounted in Franz diffusion cells. The receptor solution was sampled at 30 min, analyzed for 3 H and 14 C content, and the correlation between water and octanol absorption was determined by statistical tests suitable for non-normally distributed data. This study was conducted on skin from 37 donors with from 3 to 30 replicate skin sections per donor (a total of 426 sections). The correlation between 3 H 2 O and 14 C-octanol absorption was low (Pearson correlation coefficient = 0.3485). The 3 H 2 O absorption cutoff used in this study to select for a normal skin barrier rejected some sections in which 14 C-octanol absorption was within normal limits and accepted others in which 14 C-octanol absorption was abnormally high. The converse was true for 3 H 2 O absorption when the 14 C-octanol-based cutoff was used. The results of the 3 H 2 O test or of similar tests that primarily assess the permeability of polar pathways through the skin may not necessarily provide information relevant to the absorption of highly lipophilic compounds. Octanol, or another molecule that more closely matches the physicochemical attributes of the test compound, may characterize properties of the skin barrier that are more relevant to compounds of low water solubility.

  4. LLNA variability: An essential ingredient for a comprehensive assessment of non-animal skin sensitization test methods and strategies.

    Hoffmann, Sebastian

    2015-01-01

    The development of non-animal skin sensitization test methods and strategies is quickly progressing. Either individually or in combination, the predictive capacity is usually described in comparison to local lymph node assay (LLNA) results. In this process the important lesson from other endpoints, such as skin or eye irritation, to account for variability reference test results - here the LLNA - has not yet been fully acknowledged. In order to provide assessors as well as method and strategy developers with appropriate estimates, we investigated the variability of EC3 values from repeated substance testing using the publicly available NICEATM (NTP Interagency Center for the Evaluation of Alternative Toxicological Methods) LLNA database. Repeat experiments for more than 60 substances were analyzed - once taking the vehicle into account and once combining data over all vehicles. In general, variability was higher when different vehicles were used. In terms of skin sensitization potential, i.e., discriminating sensitizer from non-sensitizers, the false positive rate ranged from 14-20%, while the false negative rate was 4-5%. In terms of skin sensitization potency, the rate to assign a substance to the next higher or next lower potency class was approx.10-15%. In addition, general estimates for EC3 variability are provided that can be used for modelling purposes. With our analysis we stress the importance of considering the LLNA variability in the assessment of skin sensitization test methods and strategies and provide estimates thereof.

  5. Development of an artificial neural network model for risk assessment of skin sensitization using human cell line activation test, direct peptide reactivity assay, KeratinoSens™ and in silico structure alert parameter.

    Hirota, Morihiko; Ashikaga, Takao; Kouzuki, Hirokazu

    2018-04-01

    It is important to predict the potential of cosmetic ingredients to cause skin sensitization, and in accordance with the European Union cosmetic directive for the replacement of animal tests, several in vitro tests based on the adverse outcome pathway have been developed for hazard identification, such as the direct peptide reactivity assay, KeratinoSens™ and the human cell line activation test. Here, we describe the development of an artificial neural network (ANN) prediction model for skin sensitization risk assessment based on the integrated testing strategy concept, using direct peptide reactivity assay, KeratinoSens™, human cell line activation test and an in silico or structure alert parameter. We first investigated the relationship between published murine local lymph node assay EC3 values, which represent skin sensitization potency, and in vitro test results using a panel of about 134 chemicals for which all the required data were available. Predictions based on ANN analysis using combinations of parameters from all three in vitro tests showed a good correlation with local lymph node assay EC3 values. However, when the ANN model was applied to a testing set of 28 chemicals that had not been included in the training set, predicted EC3s were overestimated for some chemicals. Incorporation of an additional in silico or structure alert descriptor (obtained with TIMES-M or Toxtree software) in the ANN model improved the results. Our findings suggest that the ANN model based on the integrated testing strategy concept could be useful for evaluating the skin sensitization potential. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Comparison between sensitivity of autologous skin serum test and autologous plasma skin test in patients with Chronic Idiopathic Urticaria for detection of antibody against IgE or IgE receptor (FcεRIα).

    Sajedi, Vahid; Movahedi, Masoud; Aghamohammadi, Asghar; Aghamohamadi, Asghar; Gharagozlou, Mohammad; Ghareguzlou, Mohammad; Shafiei, Alireza; Soheili, Habib; Sanajian, Nahal

    2011-06-01

    Intradermal injection of autologous serum and plasma elicit a cutaneous reactivity in almost 45-60% of patients with Chronic Idiopathic Urticaria (CIU). This reactivity is associated with the presence of auto antibodies against IgE or IgE receptors. This study was carried out to compare the cutaneous reactivity of autologous serum and plasma skin tests in a series of patients with CIU for diagnosis of auto antibodies against IgE or IgE receptor. Fifty eight patients with CIU were injected intradermally with autologous serum and plasma (anticoagulated by citrate). Histamine was used as positive control and normal saline as negative control. The study group was checked by routine laboratory tests (CBC, U/A etc), allergens with skin prick tests, and serum IgE level, and auto antibodies against thyroid as well. Duration of urticaria was another factor which was assessed.There was no significant difference between positive ASST and positive APST patients for the above mentioned tests. 77.6% of the patients were Positive for APST and 65.5% were ASST positive. Duration of urticaria was longer in patients with positive ASST and APST than ASST and APST negative patients, although the difference was not statistically significant.Autologus serum skin test (ASST) and autologous plasma skin test (APST) could be used for estimation of duration and severity of urticaria and planning for the treatment.

  7. Impact damage and residual strength analysis of composite panels with bonded stiffeners. [for primary aircraft structures

    Madan, Ram C.; Shuart, Mark J.

    1990-01-01

    Blade-stiffened, compression-loaded cover panels were designed, manufactured, analyzed, and tested. All panels were fabricated from IM6/1808I interleafed graphite-epoxy. An orthotropic blade stiffener and an orthotropic skin were selected to satisfy the design requirements for an advanced aircraft configuration. All specimens were impact damaged prior to testing. Experimental results were obtained for three- and five-stiffener panels. Analytical results described interlaminar forces caused by impact and predicted specimen residual strength. The analytical results compared reasonably with the experimental results for residual strength of the specimens.

  8. Nuclear electronics equipment for control and monitoring panel. Ratemeter data and test methods

    1977-09-01

    This document first reviews the main notations used, and some definitions, then states its scope and gives a bibliography. The main characteristics of ratemeter electronic sub-assemblies are then given, and corresponding test methods are described. This type of instrument indicates, on a linear or logarithmic scale, the counting rate of pulses applied to its input. The document reviews analogue and digital ratemeters with linear or logarithmic characteristics, for general purpose applications, reactor control, health physics, plant and laboratory applications. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials, plant operators and, generally, for members of the electronics profession [fr

  9. Panel Analysis

    Brænder, Morten; Andersen, Lotte Bøgh

    2014-01-01

    Based on our 2013-article, ”Does Deployment to War Affect Soldiers' Public Service Motivation – A Panel Study of Soldiers Before and After their Service in Afghanistan”, we present Panel Analysis as a methodological discipline. Panels consist of multiple units of analysis, observed at two or more...... in research settings where it is not possible to distribute units of analysis randomly or where the independent variables cannot be manipulated. The greatest disadvantage in regard to using panel studies is that data may be difficult to obtain. This is most clearly vivid in regard to the use of panel surveys...... points in time. In comparison with traditional cross-sectional studies, the advantage of using panel studies is that the time dimension enables us to study effects. Whereas experimental designs may have a clear advantage in regard to causal inference, the strength of panel studies is difficult to match...

  10. QSAR models of human data can enrich or replace LLNA testing for human skin sensitization

    Alves, Vinicius M.; Capuzzi, Stephen J.; Muratov, Eugene; Braga, Rodolpho C.; Thornton, Thomas; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2016-01-01

    Skin sensitization is a major environmental and occupational health hazard. Although many chemicals have been evaluated in humans, there have been no efforts to model these data to date. We have compiled, curated, analyzed, and compared the available human and LLNA data. Using these data, we have developed reliable computational models and applied them for virtual screening of chemical libraries to identify putative skin sensitizers. The overall concordance between murine LLNA and human skin ...

  11. Nuclear electronic equipment for control and monitoring panel. Specifications and methods for testing radiation detectors

    Roguin, Andre.

    1976-02-01

    This document will be of interest to users and makers of neutron and gamma radiations detectors in the field of nuclear reactor control and protection. Information is given which will enable users to optimize their choice and methods of using equipment, and makers to optimize their methods of fabrication. It should also serve as a model from which official specifications, technical instructions and test methods for these detectors, could be established. A detailed description is given of the appropriate parameters, terminology and notations. General specifications, operating conditions and test methods are indicated. The following detectors are studied: in-core detectors: fission ionization chambers, self powered neutron detectors (S.P.N.D.); out-core detectors: boron ionization chambers (for monitoring), boron trifluoride proportional counter tubes, boron lined proportional counter tubes, helium-3 proportional counter tubes. The devices described in the document are intended for industrial radiation monitoring applications and not for calibration standards (dosimetry) or for health physics measurement purposes. They are characterized by their fidelity, fast response, reliability and long lifetimes [fr

  12. Evaluation, testing and application of participatory approaches in the Czech Republic Consensus panel - Spent nuclear fuel management alternatives. Deliverable 11

    Vojtechova, Hana

    2009-06-01

    An important part of the ARGONA project is the testing and application of novel participation and dialogue approaches. The ways in this is being done include a series of events involving different stakeholders such as a focused science shop, a consensus panel and an interaction panel. In the framework of these activities in the Czech Republic the consensus panel was held on June 12, 2008 in Rez and addressed the theme: 'Spent nuclear fuel management alternatives'. The main goals of this consensus panel were: 1. Identification of the main criteria relevant to the assessment of the existing alternatives and determination their importance (weight) from the perspective of all stakeholders; 2. Achieving at least a partial consensus on selecting the most suitable alternative (management of radioactive waste and spent nuclear fuel). A broader audience was selected with a suitable mixture of specialists and interested technical and non-technical peers including representatives from NRI, universities, Ministry of Industry and Trade, Ministry of the Environment, State Office for Nuclear Safety and Radioactive Waste Repository Authority, representatives of municipalities and NGOs, and waste producers such as CEZ plc etc. In opinion of all participants, there was a 'safe space' for debate ensured and everyone had the same opportunity to express his opinion. All participants also agreed that the whole course of seminar was transparent and correct. From this perspective, the chosen format of dialogue seems appropriate to ensure the exchange of new information and mutual discussion among the interested parties on the contentious issues in the NWM and nuclear energy in general. It was also found, however, that at present the social and political problems are the most important and the most urgent problems in the field of the nuclear waste management in the Czech Republic. It is very important not only to ensure a safe space for meaningful communication, but also: - To increase the

  13. Diagnostic evaluation of a large group of patients with immediate allergy to penicillins: the role of skin testing.

    Torres, M J; Romano, A; Mayorga, C; Moya, M C; Guzman, A E; Reche, M; Juarez, C; Blanca, M

    2001-09-01

    Penicillin is no longer the most commonly prescribed beta-lactam, and the pattern of reactions has changed. We studied the diagnostic value of skin testing in penicillin-allergic subjects from a population where benzylpenicillin is not now the most frequently used beta-lactam. Patients with a history of immediate allergic reactions to penicillins were studied with: skin tests with major and minor determinants of benzylpenicillin (BPO/MDM), amoxicillin, and ampicillin; in vitro determination of specific IgE; and controlled administration for those with a positive history but negative skin and in vitro tests. A reaction was considered immediate when symptoms appeared within a maximum of 1 h after drug intake. After testing, 290 patients (71% having anaphylaxis and 29% having urticaria) proved to be allergic. Amoxicillin was involved in 64.8% and benzylpenicillin in 2.8% of the patients. Skin test positivity to at least one determinant appeared in 70% of cases, amoxicillin being the most frequent. The overall sensitivity decreased markedly when only BPO and MDM were considered. In 13.1% of patients, the diagnosis was established by in vitro test and in 16.9% by controlled administration. Of the 290 patients, 42.1% were positive to determinants generated from benzylpenicillin and 57.9% were selective responders. Sensitivity of skin tests to BPO was lower than reported, being partly replaced by minor determinants, mostly amoxicillin. The incorporation of additional reagents and the development of new tests are required, and these will probably change as the patterns of consumption vary.

  14. New evidence on the convergence of per capita carbon dioxide emissions from panel seemingly unrelated regressions augmented Dickey-Fuller tests

    Lee, Chien-Chiang; Chang, Chun-Ping

    2008-01-01

    Using the data for per capita carbon dioxide (CO 2 ) emissions relative to the average per capita emissions for 21 countries in the organisation for economic co-operation and development (OECD) covering the period 1960-2000, this paper seeks to determine whether the stochastic convergence and β-convergence of CO 2 emissions are supported in countries with the same level of development. In other words, are shocks to relative per capita CO 2 emissions temporary in industrialized countries? We respond to this question by utilizing Breuer et al.'s [Breuer JB, McNown R, Wallace MS. Misleading inferences from panel unit-root tests with an illustration from purchasing power parity. Review of International Economics 2001;9(3):482-93; Breuer JB, McNown R, Wallace MS. Series-specific unit-root tests with panel data. Oxford Bulletin of Economics and Statistics 2002 64(5):527-46] panel seemingly unrelated regressions augmented Dickey-Fuller (SURADF) unit-root tests, which allow us to account for possible cross-sectional effects and to identify how many and which members of the panel contain a unit root. Our empirical findings provide evidence that relative per capita CO 2 emissions in OECD countries are a mixture of I(0) and I(1) processes, in which 14 out of 21 OECD countries exhibit divergence. The results reveal that conventional panel unit-root tests can lead to misleading inferences biased towards stationarity even if only one series in the panel is strongly stationary. (author)

  15. Systematic evaluation of non-animal test methods for skin sensitisation safety assessment

    Reisinger, K.; Hoffmann, S.; Alépée, N.; Ashikaga, T.; Barroso, J.; Elcombe, C.; Gellatly, N.; Galbiati, V.; Gibbs, S.; Groux, H.; Hibatallah, J.; Keller, D.; Kern, P.; Klaric, M.; Kolle, S.; Kuehnl, J.; Lambrechts, N.; Lindstedt, M.; Millet, M.; Martinozzi-Teissier, S.; Natsch, A.; Petersohn, D.; Pike, I.; Sakaguchi, H.; Schepky, A.; Tailhardat, M.; Templier, M.; van Vliet, E; Maxwell, G.

    2015-01-01

    The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has

  16. Out-of-autoclave manufacturing of a stiffened thermoplastic carbon fibre PEEK panel

    Flanagan, M.; Goggins, J.; Doyle, A.; Weafer, B.; Ward, M.; Bizeul, M.; Canavan, R.; O'Bradaigh, C.; Doyle, K.; Harrison, N.

    2017-10-01

    Out-of-Autoclave manufacturing methods, specifically Automated Tape Placement (ATP) and induction welding, used in the fabrication of a stiffened thermoplastic demonstrator panel, are presented in this study. The demonstrator panel consists of two stiffeners induction welded to a flat skin, to form a typical load bearing aerospace sub-component. The skin of the panel is manufactured from uni-directional Carbon Fibre (CF) Polyetheretherkeytone (PEEK) using laser assisted Automated Tape Placement (ATP) and the stiffeners are press formed from woven CF-PEEK. The stiffeners are fusion bonded to the skin using a continuous induction welding process. A susceptor material is used at the interface to ensure the required heating is concentrated at the weldline. Microscopy was used to examine the manufactured coupons for defects. Destructive testing was carried out to evaluate the strength of the overall assembly. The work shows that assemblies manufactured using continuous induction welding and ATP are suitable for load bearing aerospace applications.

  17. Fabrication of metallic honeycomb panels for reusable TPS - structures

    Tabernig, B.; Thierfelder, W.; Alber, H.; Sudmeijer, K.

    2001-01-01

    The manufacturing technology with specific regard to high temperature brazing was developed to fabricate a honeycomb panel consisting of a thin-sectioned PM 2000 core material sandwiched on both sides with PM 1000 face sheets. For brazing the PM 1000 / PM 2000 panel the braze alloy PdNi was selected due to the best oxidation behavior while good mechanical properties and wetting behavior compared with other tested filler alloys. To examine the concept of a hybrid PM 1000/2000 panel as a stiffened skin panel a number of engineering test samples of sub-scale and two full-size panels were fabricated at Plansee AG and supplied to Fokker Space for testing under representative in-service conditions. Engineering tests showed that the test samples were rather insensitive to temperature gradients even at temperature differences between the face sheets of 550 o C. The engineering test samples exhibited no plastic deformation after testing at different heating rates ranging from 5 to 40 o C/s and at temperature profiles representative for two flights. The requirement for the designed application regarding impact properties at low as well as high speed were met. Impact at low speed with an energy of 8 J did not cause any cracks. Hail tests where ice bullets were fired with speeds to 208 m/s at different angles from 25 o to 90 o C against the test piece showed no damage at 25 o and caused slight indentation at 45 o and cracks at 90 o , which demonstrated a good performance for the fly through a hail cloud without any problems. In tests to determine the response of a full-size panel to a number of simulated thermo-mechanical flight load cycles the panel passed 50 cycles successfully without damage. (author)

  18. Panel and planar experimental shear behavior of wood panels ...

    Panel shear strength along the thickness and planar shear along the length of wood panels laminated softwood oriented OSB 10 mm thick, conditioned at different moisture contents (anhydrous medium, ambient temperature and humid medium) was measured on standardized test specimens, cut in half lengthwise panel ...

  19. Medical clowns ease anxiety and pain perceived by children undergoing allergy prick skin tests.

    Goldberg, A; Stauber, T; Peleg, O; Hanuka, P; Eshayek, L; Confino-Cohen, R

    2014-10-01

    Intervention of medical clowns (MC) during various medical procedures performed in children has been used to relieve anxiety and pain. Their role in allergy skin testing has never been evaluated. To evaluate whether MC can diminish pain and anxiety perceived by children undergoing allergy skin prick tests (SPT). In a prospective, randomized, controlled, and blinded study, children undergoing SPT were or were not accompanied by MC. All parents and children ≥8 years completed the State-Trait Anxiety Inventory (STAI) before and after SPT. Videotapes recorded during the procedure were scored for anxiety (m-YPAS) for all children and for pain (FLACC) for children 2-7 years old by a psychologist who was unaware of the MC's presence. After SPT, children ≥8 years completed a visual analog score (VAS) for pain. Ninety-one children (mean age 8.2 years, M/F = 54/37) were recruited of whom 45 were accompanied by clowns. A significant reduction in state-STAI was found in the clowns group, in both parents and children, when compared with the regular group (26.9 ± 6.6 and 32.3 ± 10.0; P = 0.004, and 27.1 ± 4.2 and 34.3 ± 7.6; P = 0.002, respectively). Both m-YPAS and FLACC were reduced in the clowns group compared with the regular one. In the clowns group, m-YPAS positively correlated with both VAS and FLACC (P = 0.000 and 0.002, respectively). m-YPAS was positively correlated with FLACC in the regular group (P = 0.000). Medical clowns significantly decrease the level of anxiety perceived by both children undergoing allergy SPT and their parents, as well as the pain perceived by young children. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Bowing and expansion of natural stone panels: marble and limestone testing and assessment

    Grelk, Bent

    2008-06-01

    Full Text Available Natural stone has been used as a building material for centuries. In the past, load bearing members were made of entirely of stone, but in the last 50 years new processing techniques have made the production and use of thin facade cladding a profitable venture. Unfortunately however, marble facades on buildings in Europe and elsewhere have undergone severe deterioration. The EC-financed TEAM project (2000-2005 studied the bowing observed on marble facades in both cold and warm climates. TEAM’s main objectives were to understand and explain the expansion, bowing, and strength loss mechanisms governing the decay of marble- and limestone-clad facades, and to draft new European standards to prevent the use of marble and limestone poorly suited to outdoor cladding. A survey of some 200 buildings afforded a clear picture of the geographical, geological and climatic scope of the problem. Detailed case studies of six buildings resulted in a facade assessment methodology that included a monitoring system and risk assessment. Both laboratory and field research was conducted on almost 100 different types of stone from different countries and in place in different climates. The outcome was the determination of the decay mechanisms and critical factors. Two test methods and respective precision statements, one for bowing and the other for irreversible thermal expansion in high humidity conditions, were prepared for submission to CEN TC 246.La piedra natural se ha empleado como material de construcción durante siglos. En el pasado, se solía utilizar en elementos de carga, pero en los últimos 50 años las nuevas técnicas de procesamiento han permitido que sea comercialmente rentable producir y utilizar revestimientos para fachadas de espesor reducido. Desafortunadamente, numerosas fachadas de mármol de edificios tanto en Europa como fuera de ella han sufrido graves problemas derivados del deterioro de la piedra. El proyecto TEAM (2000

  1. Decontamination efficiency of detergents on the market for the skin contaminated with radioactive materials. The comparative test (1)

    Miyabe, Kenjiro; Ninomiya, Kazushi; Takasaki, Koji; Horiuchi, Nobuharu; Yasunaka, Hideo; Izumi, Yuichi

    1999-04-01

    Contamination incidence on human body and skin happens sometimes during radiation works in controlled area. The radioactive surface contamination should be removed from the skin as soon as possible for radiation control and exposure management. Titanium oxide paste, which is reserved as a detergent for decontamination, has a satisfactory and reliable result for decontamination effects. The titanium oxide paste, however, has a short preservation period, and must be updated and supplied every serenal months. Decontamination tests for about 60 kinds of detergents on the market were carried out with swine and radioactive material, Ce-144. Radioactive solution of Ce-144 was dropped on the test samples of swine skin, which were left for 5 min or 40 min as it is. Radioactivities of the samples were measured before and after washing by the detergents. As a result of the decontamination tests, 22 kinds of detergents on the market which have a similar decontamination efficiency to the titanium oxide paste were selected. It was also ascertained that the decontamination efficiency of all the detergents decreased on the test samples which were immersed in the radioactive solution for 40 min and wounded on skin surface. (Suetake, M.)

  2. Tuberculin skin test and QuantiFERON® assay in young children investigated for tuberculosis in South Africa

    Moyo, S.; Isaacs, F.; Gelderbloem, S.; Verver, S.; Hawkridge, A. J.; Hatherill, M.; Tameris, M.; Geldenhuys, H.; Workman, L.; Pai, M.; Hussey, G.; Hanekom, W. A.; Mahomed, H.

    2011-01-01

    Although the literature on interferon-gamma release assays on tuberculosis (TB) in children has increased, data pertaining to young children remain relatively limited. To compare results from the tuberculin skin test (TST) and the QuantiFERON®-TB Gold In-Tube assay (QFT) in children aged <3 years

  3. F-15B in on ramp with close-up of test panels covered with advanced spray-on foam insulation materia

    1999-01-01

    Test panels covered with an advanced foam insulation material for the Space Shuttle's giant external fuel tank were test flown aboard an F-15B research aircraft at NASA's Dryden Flight Research Center, Edwards, Calif. Six panels were mounted on the left side of a heavily instrumented Flight Text Fixture mounted underneath the F-15B's fuselage. Insulation on this panel was finely machined over a horizontal rib structure to simulate in-line airflow past the tank; other panels had the ribs mounted vertically or had the insulation left in a rough as-sprayed surface. The tests were part of an effort by NASA's Marshall Space Flight Center to determine why small particles of the new insulation flaked off the tank on recent Shuttle missions. The tests with Dryden's F-15B were designed to replicate the pressure environment the Shuttle encounters during the first minute after launch. No noticeable erosion of the insulation material was noted after the flight experiment at Dryden.

  4. Manufacturing and testing of active composite panels with embedded piezoelectric sensors and actuators: wires out by molded-in holes

    Ghasemi-Nejhad, Mehrdad N.; Pourjalali, Saeid

    2003-08-01

    This work presents manufacturing and testing of active composite panels (ACPs) with embedded piezoelectric sensors and actuators. The composite material employed here is a plain weave carbon epoxy prepreg fabric with about 0.33 mm ply thickness. The piezoelectric patches employed here are Continuum Control Corporation, CCC, (recently Continuum Photonics, Inc) active fiber composite patches with 0.33 mm thickness, i.e. close to the composite ply thickness. Composite cut-out layers are used to fill the space around the embedded piezoelectric patches to minimize the problems associated with ply drops in composites. The piezoelectric patches were embedded inside the composite laminate. High-temperature wires were soldered to the piezoelectric leads, insulated from the carbon substructure by high-temperature materials, and were taken out of the composite laminates employing a molded-in hole technique that reduces the stress concentration as opposed to a drilled hole, and thereby enhancing the performance of the composite structure. The laminated ACP"s were co-cured inside an autoclave employing the cure cycle recommended by the composite material supplier. The curie temperature of the embedded piezoelectric patches should be well above the curing temperature of the composite materials as was the case here. The manufactured ACP beams and plates were trimmed and then tested for their functionality. Vibration suppression as well as simultaneous vibration suppression and precision positioning tests, using PID control as well as Hybrid Adaptive Control techniques were successfully conducted on the manufactured ACP beams and their functionality were demonstrated. Recommendations on the use of this embedding technique for ACPs are provided.

  5. Identification of low allergenic apple cultivars using skin prick tests and oral food challenges.

    Vlieg-Boerstra, B J; van de Weg, W E; van der Heide, S; Kerkhof, M; Arens, P; Heijerman-Peppelman, G; Dubois, A E J

    2011-04-01

    As oral allergy syndrome (OAS) symptoms to apple are frequent, we aimed to identify low allergenic apple cultivars and to validate the prick-to-prick skin prick test (SPT) as a suitable screening method. Sixty-eight apple cultivars were tested by SPTs in 33 Dutch adults with OAS, before and during the birch pollen season in 2006 and 2007, respectively. Three cultivars yielding the largest number of negative SPTs (Elise, Santana and Pink Lady®) and one reference cultivar (Golden Delicious) were subsequently tested by single-blind oral food challenges (SBFC) just after picking in fall 2007 (fresh) and in spring 2008 (stored), outside the birch pollen season and preceded by SPTs. In spring, Santana was replaced by Modi®. In fresh apples, OAS symptoms of Elise, as measured by cumulative scores on a Visual Analogue Scale VASt, were significantly lower than those of Santana, Pink Lady and Golden Delicious (P = 0.021; 0.040 and 0.005, respectively). VASt scores of Santana were significantly lower than those of Golden Delicious (P = 0.049). In stored apples, VASt scores of Elise were significantly lower than that of Golden Delicious (P = 0.038). VASt scores of fresh apples did not differ significantly from stored apples, except in Golden Delicious (spring < fall: P = 0.021). The SPTs did not predict the severity of OAS. SPTs are not useful to assess the allergenicity of apple cultivars. By using SBFC, Elise and Santana were identified as low allergenic apple cultivars in patient with OAS. Our data on the effect of storage are inconclusive. © 2010 John Wiley & Sons A/S.

  6. The Clinical Test of Nano gold Cosmetic for Recovering Skin Damage Due to Chemicals: Special Case

    Taufikurohmah, T.; Wardana, A. P.; Tjahjani, S.; Sanjaya, I. G. M.; Baktir, A.; Syahrani, A.

    2018-01-01

    Manufacturing of Nano gold cosmetics was done at PT. Gizi Indonesia. Clinical trials to cosmetics data supported that cosmetics are able to treat skin health which has been reported partially. For special cases, the recovery process of facial skin damage should also receive attention including cases of facial skin damage caused by chemicals such as phenol, HCl, aqua regia or other harsh chemicals. The problem determined whether the Nano gold is able to recover skin damage due to the harsh chemicals. This clinical trial data on the forms of early skin damage caused by phenol was delivered in the forms of facial photos patients. The recovery progress of facial skin condition was obtained every week for two months. The data included the forms of widespread wounds during the recovery process. This statement supported by anova statistical analysis of the widespread wound changing every week for 8 times. The conclusion is skin damage due to Phenol impregnation can be recovered with the use of Nano gold cosmetics for 8 weeks. This results support the manufacturing of Nano gold cosmetics for the needs of society. It also suggest that Nano gold material can be used for medicine manufacturing in the future.

  7. [IFN-gamma enzyme-linked immunospot assay versus PPD tuberculin skin test in the diagnosis of tuberculous epididymitis].

    Huang, Hao; Yang, Xi-Fei; Deng, Qun-Yi; Li, Bing; Liu, Guo-Hui; Zhang, Jie-Yun; Yang, Da-Fei

    2012-06-01

    To explore the potential application of IFN-gamma enzyme-linked immunospot (ELISPOT) assay in the diagnosis of tuberculous epididymitis (TE) by comparing ELISPOT assay with the traditional purified protein derivative (PPD) tuberculin skin test. We examined 13 TE patients using an in-house ELISPOT kit, another 11 TE patients by PPD skin testing, and 57 healthy male volunteers by parallel test with both the methods. Twelve (92.3%) of the 13 TE cases were positive on ELISPOT assay, and 10 (90.9%) of the 11 TE cases positive on PPD skin test, with no statistically significant differences between the two groups (P > 0.05). Among the 57 healthy male volunteers, 8 (14.0%) were positive on ELISPOT, and 28 (49.1%) positive on PPD test, the latter significantly higher than the former (P PPD test in the examination of tuberculous epididymitis. As for specificity, ELISPOT assay seems better than PPD test in differentiating tuberculous epididymitis patients from healthy males.

  8. Risk of redocumenting penicillin allergy in a cohort of patients with negative penicillin skin tests.

    Rimawi, Ramzy H; Shah, Kaushal B; Cook, Paul P

    2013-11-01

    Even though electronic documentation of allergies is critical to patient safety, inaccuracies in documentation can potentiate serious problems. Prior studies have not evaluated factors associated with redocumenting penicillin allergy in the medical record despite a proven tolerance with a penicillin skin test (PST). Assess the prevalence of reinstating inaccurate allergy information and associated factors thereof. We conducted a retrospective observational study from August 1, 2012 to July 31, 2013 of patients who previously had a negative PST. We reviewed records from the hospital, long-term care facilities (LTCF), and primary doctors' offices. Vidant Health, a system of 10 hospitals in North Carolina. Patients with proven penicillin tolerance rehospitalized within a year period from the PST. We gauged hospital reappearances, penicillin allergy redocumentation, residence, antimicrobial use, and presence of dementia or altered mentation. Of the 150 patients with negative PST, 55 (37%) revisited a Vidant system hospital within a 1-year period, of whom 21 were LTCF residents. Twenty (36%) of the 55 patients had penicillin allergy redocumented without apparent reason. Factors associated with penicillin allergy redocumentation included age >65 years (P = 0.011), LTCF residence (P = 0.0001), acutely altered mentation (P Penicillin allergy was still listed in all 21 (100%) of the LTCF records. At our hospital system, penicillin allergies are often redocumented into the medical record despite proven tolerance. The benefits of PST may be limited by inadequately removing the allergy from different electronic/paper hospital, LTCF, primary physician, and community pharmacy records. © 2013 Society of Hospital Medicine.

  9. Testing a linear time invariant model for skin conductance responses by intraneural recording and stimulation.

    Gerster, Samuel; Namer, Barbara; Elam, Mikael; Bach, Dominik R

    2018-02-01

    Skin conductance responses (SCR) are increasingly analyzed with model-based approaches that assume a linear and time-invariant (LTI) mapping from sudomotor nerve (SN) activity to observed SCR. These LTI assumptions have previously been validated indirectly, by quantifying how much variance in SCR elicited by sensory stimulation is explained under an LTI model. This approach, however, collapses sources of variability in the nervous and effector organ systems. Here, we directly focus on the SN/SCR mapping by harnessing two invasive methods. In an intraneural recording experiment, we simultaneously track SN activity and SCR. This allows assessing the SN/SCR relationship but possibly suffers from interfering activity of non-SN sympathetic fibers. In an intraneural stimulation experiment under regional anesthesia, such influences are removed. In this stimulation experiment, about 95% of SCR variance is explained under LTI assumptions when stimulation frequency is below 0.6 Hz. At higher frequencies, nonlinearities occur. In the intraneural recording experiment, explained SCR variance is lower, possibly indicating interference from non-SN fibers, but higher than in our previous indirect tests. We conclude that LTI systems may not only be a useful approximation but in fact a rather accurate description of biophysical reality in the SN/SCR system, under conditions of low baseline activity and sporadic external stimuli. Intraneural stimulation under regional anesthesia is the most sensitive method to address this question. © 2017 The Authors. Psychophysiology published by Wiley Periodicals, Inc. on behalf of Society for Psychophysiological Research.

  10. Frozen fruit skin prick test for the diagnosis of fruit allergy.

    Garriga, Teresa; Guilarte, Mar; Luengo, Olga; Guillén, Mercé; Labrador-Horrillo, Moisés; Fadeeva, Tatiana; Sala, Anna; Cardona, Victória

    2010-12-01

    Diagnosis of fruit sensitisation by skin prick test (SPT) is fast and easy to perform. Nevertheless, some fruit is not available throughout the year. Freezing aliquots of these fresh fruits to be defrosted would be a good solution to perform SPT at any time. To compare the reproducibility of SPT with Rosaceae and Cucurbitaceae frozen fruit with fresh and commercial fruit extracts. SPT with the following fruit were performed: apricot, cherry, strawberry, nectarine, Japanese medlar, peach, (peel and pulp), yellow and red plum, melon and watermelon. We compared fresh fruit, commercial extract and fruit which had been frozen at -18 degrees C. Results were read by planimetry (Inmunotek prick-film) after 15 minutes. The study group comprised 48 patients (9 males, 39 females) with a mean age of 31, 6 +/- 2.0 years. Concordance of positive and negative results was extremely high and significant in all cases. Correlation between frozen fruit and commercial extract, frozen fruit and fresh and commercial extract and fresh fruit was statistically significant in all cases except for strawberry. The use of frozen fruit is a valid method, as the performance of the SPT is similar to that of fresh fruit. This enables diagnostic procedures with seasonal fruit at any time of the year.

  11. Results of molten salt panel and component experiments for solar central receivers: Cold fill, freeze/thaw, thermal cycling and shock, and instrumentation tests

    Pacheco, J.E.; Ralph, M.E.; Chavez, J.M.; Dunkin, S.R.; Rush, E.E.; Ghanbari, C.M.; Matthews, M.W.

    1995-01-01

    Experiments have been conducted with a molten salt loop at Sandia National Laboratories in Albuquerque, NM to resolve issues associated with the operation of the 10MW{sub e} Solar Two Central Receiver Power Plant located near Barstow, CA. The salt loop contained two receiver panels, components such as flanges and a check valve, vortex shedding and ultrasonic flow meters, and an impedance pressure transducer. Tests were conducted on procedures for filling and thawing a panel, and assessing components and instrumentation in a molten salt environment. Four categories of experiments were conducted: (1) cold filling procedures, (2) freeze/thaw procedures, (3) component tests, and (4) instrumentation tests. Cold-panel and -piping fill experiments are described, in which the panels and piping were preheated to temperatures below the salt freezing point prior to initiating flow, to determine the feasibility of cold filling the receiver and piping. The transient thermal response was measured, and heat transfer coefficients and transient stresses were calculated from the data. Freeze/thaw experiments were conducted with the panels, in which the salt was intentionally allowed to freeze in the receiver tubes, then thawed with heliostat beams. Slow thermal cycling tests were conducted to measure both how well various designs of flanges (e.g., tapered flanges or clamp type flanges) hold a seal under thermal conditions typical of nightly shut down, and the practicality of using these flanges on high maintenance components. In addition, the flanges were thermally shocked to simulate cold starting the system. Instrumentation such as vortex shedding and ultrasonic flow meters were tested alongside each other, and compared with flow measurements from calibration tanks in the flow loop.

  12. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of a health claim related to Wheat Polar Lipid Extract and protection of the skin against dehydration pursuant to Article 13(5) of Regulation (EC) No 1924/2006

    Tetens, Inge

    Following an application from Extraction Purification Innovation France, submitted pursuant to Article 13(5) of Regulation (EC) No 1924/2006 via the Competent Authority of France, the Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to deliver an opinion on the scientific...... substantiation of a health claim related to Wheat Polar Lipid Extract and protection of the skin against dehydration. The Panel considers that Wheat Polar Lipid Extract is sufficiently characterised. The claimed effect is “contributes to improve skin hydration”. The target population proposed by the applicant...... can be drawn from one uncontrolled pilot study, nor from one study which was not carried out with the food which is the subject of the claim. In weighing the evidence, the Panel took into account that one human intervention study reported an effect of consumption of Wheat Polar Lipid Extract...

  13. Histological and Immunological Description of the Leishmanin Skin Test in Ibizan Hounds.

    Ordeix, L; Silva, J E Dos S; Llull, J; Quirola, P; Montserrat-Sangrà, S; Martínez-Orellana, P; Solano-Gallego, L

    2018-01-01

    The leishmanin skin test (LST), a delayed-type hypersensitivity (DTH) reaction to Leishmania infantum, can specifically identify dogs that have made a cell-mediated immune response to L. infantum infection. The Ibizan hound appears to be more resistant to L. infantum infection than other breeds of dog. The aim of this study was to describe the histological and immunohistochemical changes induced by the LST in Ibizan hounds living in an area highly endemic for leishmaniosis. The majority of dogs were apparently healthy, lacked serum antibody to L. infantum and blood parasitaemia, but had marked specific interferon gamma production after in-vitro blood stimulation with L. infantum. Leishmanin (3 × 10 8 killed promastigotes of L. infantum/ml) was injected intradermally and biopsy samples were obtained from a positive reaction at 72 h from nine Ibizan hounds. A moderate to intense, perivascular to interstitial dermatitis and panniculitis characterized the inflammatory response at the injection site. In addition, three samples had diffuse inflammation in the deep dermis and panniculus. Oedema and necrosis were present in the deep dermis and panniculus. Congestion and haemorrhage were observed in five biopsies. T lymphocytes (CD3 + ) and large mononuclear cells (lysozyme - ) were the most prevalent cells. CD3 + cells were significantly more numerous than CD20 + B cells and lysozyme + cells. B cells were sparsely distributed, especially in the deep dermis and panniculus. Rare neutrophils and macrophages (lysozyme + ) were observed with few eosinophils. Toll-like receptor (TLR)-2 protein was expressed in large mononuclear cells mainly located in the superficial dermis. Leishmania immunohistochemistry was negative and quantitative polymerase chain reaction was positive in all cases. The intradermal injection of killed L. infantum promastigotes in Ibizan hounds causes similar histological and immunohistochemical findings to those described for human subjects and are

  14. Relevance of Cat and Dog Sensitization by Skin Prick Testing in Childhood Eczema and Asthma.

    Hon, Kam Lun; Tsang, Kathy Yin Ching; Pong, Nga Hin Henry; Leung, Ting Fan

    2017-01-01

    Household animal dander has been implicated as aeroallergen in childhood atopic diseases. Many parents seek healthcare advice if household pet keeping may be detrimental in atopic eczema (AE), allergic rhinitis and asthma. We investigated if skin sensitization by cat/dog dander was associated with disease severity and quality of life in children with AE. Demographics, skin prick test (SPT) results, disease severity (Nottingham eczema severity score NESS), Children Dermatology Life Quality Index (CDLQI), blood IgE and eosinophil counts of a cohort of AE patients were reviewed. 325 AE patients followed at a pediatric dermatology clinic were evaluated. Personal history of asthma was lowest (20%) in the dog-dander-positive-group but highest (61%) in bothcat- and-dog-dander-positive group (p=0.007). Binomial logistic regression ascertained that catdander sensitization was associated with increasing age (adjusted odds ratio [aOR], 1.056; 95% Confidence Interval [CI], 1.006 to 1.109; p=0.029), dust-mite sensitization (aOR, 4.625; 95% CI, 1.444 to 14.815; p=0.010), food-allergen sensitization (aOR, 2.330; 95% CI, 1.259 to 4.310; p=0.007) and keeping-cat-ever (aOR, 7.325; 95% CI, 1.193 to 44.971; p=0.032); whereas dogdander sensitization was associated with dust-mite sensitization (aOR, 9.091; 95% CI, 1.148 to 71.980; p=0.037), food-allergen sensitization (aOR, 3.568; 95% CI, 1.341 to 9.492; p=0.011) and keeping-dog-ever (aOR, 6.809; 95% CI, 2.179 to 21.281; p=0.001). However, neither cat nor dog sensitization were associated with asthma, allergic rhinitis, parental or sibling atopic status, disease severity or quality of life. Physicians should advise parents that there is no direct correlation between AE severity, quality of life, asthma or allergic rhinitis with cutaneous sensitization to cats or dogs. Sensitized patients especially those with concomitant asthma and severe symptoms may consider non-furry alternatives if they plan to have a pet. Highly sensitized

  15. ABC deck panel testing.

    2013-09-01

    Accelerated Bridge Construction techniques have resulted in innovative options that : save time and money during the construction of bridges. One such group of techniques : that has generated considerable interest is the usage of individual precast c...

  16. De-labelling self-reported penicillin allergy within the emergency department through the use of skin tests and oral drug provocation testing.

    Marwood, Joseph; Aguirrebarrena, Gonzalo; Kerr, Stephen; Welch, Susan A; Rimmer, Janet

    2017-10-01

    Self-reported penicillin allergy is common among patients attending the ED, but is a poor predictor of true immunoglobulin E-mediated hypersensitivity to penicillin. We hypothesise that with a combination of skin testing and drug provocation testing, selected patients can be safely de-labelled of their allergy. This prospective study enrolled a sample of patients presenting to an urban academic ED between 2011 and 2016 with a self-reported allergy to penicillin. Standardised skin prick and intradermal testing with amoxicillin and both major and minor determinants of penicillin was performed in the department. If negative, testing was followed by a graded oral challenge of amoxicillin over 9 days. The primary end point was the allergy status of participants at the end of the study. A total of 100 patients (mean age 42; standard deviation 14 years; 54% women) completed the testing. Of these, 81% (95% confidence interval 71.9-88.2) showed no hypersensitivity to penicillin and were labelled non-allergic. The majority (16/19) of allergies were confirmed by skin testing, with three suspected allergies detected by the oral challenge. Women were more likely than men to have a true penicillin allergy, with odds ratio of 4.0 (95% confidence interval 1.23-13.2). There were no serious adverse events. Selected patients in the ED who self-report an allergy to penicillin can be safely tested there for penicillin allergy, using skin tests and oral drug provocation testing. This testing allows a significant de-labelling of penicillin allergy, with the majority of these patients able to tolerate penicillin without incident. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  17. The effect of Ramadan fasting on tuberculin skin test and leukocyte count

    Jafar Nasiri

    2017-03-01

    Full Text Available Background & Objectives: Annually, many Muslims fast during the month of Ramadan worldwide. This practice has different favorable medical and physiological effects, such as improved serum lipid profile and blood glucose level due to changes in diet and sleep patterns. It has also been hypothesized that Ramadan fasting may affect the immune system. As reported, Ramadan fasting can influence the immunoglobulin and cytokine levels. Accordingly, tuberculin skin test or purified protein derivative (PPD test, which is a delayed-type hypersensitivity of cellular immune response, may also be affected by Ramadan fasting. Regarding this, the present study aimed to investigate the alteration of PPD test during and after Ramadan. Materials & Methods: A total of 42 males (seminary students who fasted during Ramadan in 2006 were included in the study; however, only 28 cases completed the study. For data collection, the participants underwent blood and tuberculin tests at the fourth week of Ramadan and three months after this month. The white blood cell (WBC count and the tuberculin induration were recorded and compared between the two intervals to evaluate the changes. Results: According to the results of the study, the mean age of the participants was 19.21±3.83 years. Furthermore, the mean tuberculin induration was 9.3±5.4 mm (size range: 2-22 mm on the fourth week of Ramadan, which increased to 9.79±6.8 mm (size range: 3-35 mm three months after this month (P=0.501. The mean count of WBC decreased insignificantly from 5907±1879 mcL to 5601±1362 mcL after Ramadan (P=0.334. Additionally, the mean lymphocytes count decreased significantly from 2292±520/mcL to 2023±486/mcL after this month (P=0.003. Likewise, the lymphocyte (P=0.014 and mean neutrophil percentage also reduced significantly (P0.05. Conclusion: As the findings of the present study indicated, Ramadan fasting induce some changes in the immune status, including lymphocyte and neutrophil

  18. Standardisation of defined approaches for skin sensitisation testing to support regulatory use and international adoption: position of the International Cooperation on Alternative Test Methods.

    Casati, S; Aschberger, K; Barroso, J; Casey, W; Delgado, I; Kim, T S; Kleinstreuer, N; Kojima, H; Lee, J K; Lowit, A; Park, H K; Régimbald-Krnel, M J; Strickland, J; Whelan, M; Yang, Y; Zuang, Valérie

    2018-02-01

    Skin sensitisation is the regulatory endpoint that has been at the centre of concerted efforts to replace animal testing in recent years, as demonstrated by the Organisation for Economic Co-operation and Development (OECD) adoption of five non-animal methods addressing mechanisms under the first three key events of the skin sensitisation adverse outcome pathway. Nevertheless, the currently adopted methods, when used in isolation, are not sufficient to fulfil regulatory requirements on the skin sensitisation potential and potency of chemicals comparable to that provided by the regulatory animal tests. For this reason, a number of defined approaches integrating data from these methods with other relevant information have been proposed and documented by the OECD. With the aim to further enhance regulatory consideration and adoption of defined approaches, the European Union Reference Laboratory for Alternatives to Animal testing in collaboration with the International Cooperation on Alternative Test Methods hosted, on 4-5 October 2016, a workshop on the international regulatory applicability and acceptance of alternative non-animal approaches, i.e., defined approaches, to skin sensitisation assessment of chemicals used in a variety of sectors. The workshop convened representatives from more than 20 regulatory authorities from the European Union, United States, Canada, Japan, South Korea, Brazil and China. There was a general consensus among the workshop participants that to maximise global regulatory acceptance of data generated with defined approaches, international harmonisation and standardisation are needed. Potential assessment criteria were defined for a systematic evaluation of existing defined approaches that would facilitate their translation into international standards, e.g., into a performance-based Test Guideline. Informed by the discussions at the workshop, the ICATM members propose practical ways to further promote the regulatory use and facilitate

  19. 389 Allergic Reactions to Local Anesthetics: Detection by Skin Tests and Subcutaneous Provocation. Analysis of 160 Cases

    Arcanjo, Luiz; Gonçalves Tavares, Tania Maria; Delcourt, Nathalia; Baroni, Juliana; Rios, João; Rios, José Luiz

    2012-01-01

    Background Adverse reactions to local anesthetics (LA) are frequent and often referred to as allergic. Although immune-mediated reactions are rare, it should be investigated for suspected cases. The objective of this study was to determine the frequency of positive skin test to these drugs in patients with a suspected history of allergic reactions and describe the main socio-demographic characteristics of these individuals. Methods Retrospective study of medical records of patients attended at Policlínica Geral do Rio de Janeiro Allergic Clinic, between 2008 and 2011. The parameters evaluated were the test indication and the patient ages and gender. The drug tested was that the patient had a history of suspicion. Patients underwent skin prick and intradermal tests and subcutaneous provocation. Descriptive statistical analysis of the data was performed. Results It was performed 160 tests (125 female). Three of this total was excluded due to inconclusive results. In women, the highest proportion of tests was in the age group from 41 to 60 years (43%), while in males the higher concentration was at a youngest age group: 21 to 40 years (41%). The most common indication (103 cases, 65%) for the tests was a previous suspected anaphylactic reaction by LA. Seven of 157 tests had a positive result (4.4%), 6 of them occurred in women (4.8%). Only one test resulted in a type of anaphylactic reaction response (0.67%). All patients who presented positive response to the test had a history of per-anesthetic reaction that suggested an immune-mediated mechanism. Conclusions In patients with a history of previous reaction to local anesthetics, the skin tests with these drugs have a key role in the prevention of anaphylaxis, and on guidance for adequate anesthetic procedures.

  20. Predicting the outcome of oral food challenges with hen's egg through skin test end-point titration.

    Tripodi, S; Businco, A Di Rienzo; Alessandri, C; Panetta, V; Restani, P; Matricardi, P M

    2009-08-01

    Oral food challenge (OFC) is the diagnostic 'gold standard' of food allergies but it is laborious and time consuming. Attempts to predict a positive OFC through specific IgE assays or conventional skin tests so far gave suboptimal results. To test whether skin test with titration curves predict with enough confidence the outcome of an oral food challenge. Children (n=47; mean age 6.2 +/- 4.2 years) with suspected and diagnosed allergic reactions to hen's egg (HE) were examined through clinical history, physical examination, oral food challenge, conventional and end-point titrated skin tests with HE white extract and determination of serum specific IgE against HE white. Predictive decision points for a positive outcome of food challenges were calculated through receiver operating characteristic (ROC) analysis for HE white using IgE concentration, weal size and end-point titration (EPT). OFC was positive (Sampson's score >or=3) in 20/47 children (42.5%). The area under the ROC curve obtained with the EPT method was significantly bigger than the one obtained by measuring IgE-specific antibodies (0.99 vs. 0.83, P<0.05) and weal size (0.99 vs. 0.88, P<0.05). The extract's dilution that successfully discriminated a positive from a negative OFC (sensitivity 95%, specificity 100%) was 1 : 256, corresponding to a concentration of 5.9 microg/mL of ovotransferrin, 22.2 microg/mL of ovalbumin, and 1.4 microg/mL of lysozyme. EPT is a promising approach to optimize the use of skin prick tests and to predict the outcome of OFC with HE in children. Further studies are needed to test whether this encouraging finding can be extended to other populations and food allergens.

  1. Prospective, multicenter clinical trial to validate new products for skin tests in the diagnosis of allergy to penicillin.

    Fernández, J; Torres, M J; Campos, J; Arribas-Poves, F; Blanca, M

    2013-01-01

    Allergy to penicillin is the most commonly reported type of drug hypersensitivity. Diagnosis is currently confirmed using skin tests with benzylpenicillin reagents, ie, penicilloyl-polylysine (PPL) as the major determinant of benzylpenicillin and benzylpenicillin, benzylpenicilloate and benzylpenilloate as a minor determinant mixture (MDM). To synthesize and assess the diagnostic capacity of 2 new benzylpenicillin reagents in patients with immediate hypersensitivity reactions to B-lactams: benzylpenicilloyl octa-L-lysine (BP-OL) as the major determinant and benzylpenilloate (penilloate) as the minor determinant. Prospective multicenter clinical trial performed in 18 Spanish centers. Efficacy was assessed by detection of positive skin test results in an allergic population and negative skin test results in a nonallergic, drug-exposed population. Sensitivity, specificity, and negative and positive predictive values were determined. The study sample comprised 94 allergic patients: 31 (35.23%) presented anaphylaxis, 4 (4.55%) anaphylactic shock, 51 (58.04%) urticaria, and 2 (2.27%) no specific condition. The culprit 8-lactams were amoxicillin in 63 cases (71.60%), benzypencillin in 14 cases (15.89%), cephalosporins in 2 cases (2.27%), other drugs in 3 cases (3.42%), and unidentified agents in 6 cases (6.82%). The results of testing with BP-OL were positive in 46 cases (52.3%); the results of testing with penilloate were positive in 33 cases (37.5%). When both reagents were taken into consideration, sensitivity reached 61.36% and specificity 100%. Skin testing with penilloate was significantly more often negative when the interval between the reaction and the study was longer. The sensitivity of BP-OL and penilloate was 61%. Considering that amoxicillin was the culprit drug in 71% of reactions, these results indicate that most patients were allergic to the whole group of penicillins. These data support the use of benzylpenicillin determinants in the diagnosis of allergy

  2. Skin prick test results in patients with atopic symptoms in Yozgat district

    Emine Çölgeçen

    2014-03-01

    Full Text Available Objective: Skin prick test (SPT is used widely and fastly to determine the allergens in atopic disease. We aimed in this study to analysis the relationship between total serum IgE (T.IgE and allergens that found by SPT and looking over the frequency of allergens. Methods: We evaluated clinical findings and SPT results and T.IgE levels of 190 patients who admitted to dermatology outpatient clinic, retrospectively. Rsults: 53 (27.9% patients had idiopathic generalized pruritus (IGP, 41 (21.6% had atopic dermatitis (AD, 40 (21.1% had chronic idiopathic urticaria (CIU, 38 (20% had allergic rhinitis (AR, and 18 (9.5% had allergic asthma (AA. 123 (64.7% patients had positive reaction to at least one or more allergen on SPT. Of these patients 28 were IGP, 30 were AD, 20 were CIU, 28 were AR, and 17 were AA. The most common allergens were pine pollen (25.3%, wheat pollen (18.4%, and dog epithelium (15.8%. The mean levels of T.IgE was 382.61 ± 517.28 IU/ml (1-2500. T.IgE is higher 54.9% of patients. It was seen that DPT positivity was significantly more frequent in patients with increased T.IgE levels than those with normal total serum IgE level (p<0.05. Conclusion: We think that pine tree and wheat pollens are the most commonly encountered allergens at Yozgat area. Moreover, our findings indicated to the requirement and benefits of DPT in patients with AD, AR and AA in addition to the those KİU and İJP, particularly in patients with increased T.IgE levels, although further studies with larger sample size are needed. J Clin Exp Invest 2014; 5 (1: 64-68

  3. Oral Challenge without Skin Testing Safely Excludes Clinically Significant Delayed-Onset Penicillin Hypersensitivity.

    Confino-Cohen, Ronit; Rosman, Yossi; Meir-Shafrir, Keren; Stauber, Tali; Lachover-Roth, Idit; Hershko, Alon; Goldberg, Arnon

    Penicillins are the drug family most commonly associated with hypersensitivity reactions. Current guidelines recommend negative skin tests (ST) before re-administering penicillins to patients with previous nonimmediate reactions (NIR). The objective of this study was to examine whether ST are necessary before re-administering penicillin to patients with NIR. Patients with NIR to penicillins starting longer than 1 hour after last dose administration or starting any time after the first treatment day or patients with vague recollection of their reaction underwent penicillin ST. Disregarding ST results, patients were challenged with the relevant penicillins. One-tenth of the therapeutic dose followed by the full dose was administered at 1-hour interval and patients continued taking the full dose for 5 days. A total of 710 patients with alleged BL allergy were evaluated. Patients with a history of immediate reaction (52, 7.3%) or cephalosporin allergy (16, 2.2%) were excluded. Of the remaining 642 patients, 62.3% had negative ST, 5.3% positive ST, and 32.4% equivocal ST. A total of 617 (96.1%) patients were challenged. Immediate reaction was observed in 9 patients (1.5%): 1-positive ST, 7-negative ST, and 1-equivocal ST (P = .7). Late reaction to the first-day challenge occurred in 24 patients (4%). An at-home challenge was continued by 491 patients. Complete 5-day and partial challenges were well tolerated by 417 (85%) and 44 patients (8.9%), respectively, disregarding ST results. Thirty patients (6.1%) developed mild reactions to the home challenge regardless of their ST results. A 5-day oral challenge without preceding ST is safe and sufficient to exclude penicillin allergy after NIR developing during penicillin treatment. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. House dust bioactivities predict skin prick test reactivity for children with high risk of allergy.

    Kim, Haejin; Tse, Kevin; Levin, Linda; Bernstein, David; Reponen, Tiina; LeMasters, Grace; Lummus, Zana; Horner, Anthony A

    2012-06-01

    Although evidence suggests that ambient exposures to endotoxin and other immunostimulants during early life influence allergic risk, efforts to understand this host-environment relationship have been hampered by a paucity of relevant assays. These investigations determined whether parameters of house dust extract (HDE) bioactivity were predictive of allergen skin prick test (SPT) reactivity for infants at high risk of allergy participating in the Cincinnati Childhood Allergy and Air Pollution Study (CCAAPS). We conducted a nested case-control study, selecting 99 CCAAPS children who had positive SPT results to at least 1 aeroallergen at age 3 years and 101 subjects with negative SPT results. HDEs were prepared from dust samples collected from the subjects' homes at age 1 year. Murine splenocytes and bone marrow-derived dendritic cells were incubated with HDEs, and supernatant cytokine concentrations were determined by means of ELISA. Alternatively, bone marrow-derived dendritic cells were preincubated with HDEs, and then LPS-induced IL-6 responses were assessed. HDE endotoxin levels were determined by using the limulus amebocyte lysate assay. HDEs derived from the homes of children with positive (cases) and negative (control subjects) SPT results had similar bioactivities. However, when cases were considered in isolation, HDEs with higher levels of bioactivity were significantly associated with children who had lower numbers of positive SPT results. Analogous statistical analyses did not identify any association between HDE endotoxin levels and the aeroallergen sensitization profiles of children included in this study. HDE immunostimulatory activities predicted the aeroallergen sensitization status of CCAAPS subjects better than HDE endotoxin levels. These results provide the first published evidence that HDE bioassays have clinical relevance in predicting atopic risk. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All

  5. Graphite/epoxy orthogrid panel fabrication

    Lager, J. R.

    1978-01-01

    The structural concept considered for a spacecraft body structure is a grid stiffened skin with a skin laminate configuration and the stiffener grid geometry selected to best suit the design requirements. The orthogrid panel developed weighs 0.55 lb/sq ft and resisted an ultimate in-plane shear load of 545 lbf/in. The basic concept of a grid stiffener composite panel is that a relatively thin skin is reinforced with a gridwork of stiffeners so that the overall panel can resist design loads without becoming structurally unstable or being overstressed. The main feature of the orthogrid panel design is that it provides the potential for low cost structural panels when advanced to the production phase. The most innovative part of the fabrication method is the foam/fiberglass stiffener web grid billet fabrication and machining to size.

  6. Diagnostic value of scratch-chamber test, skin prick test, histamine release and specific IgE in birch-allergic patients with oral allergy syndrome to apple

    Osterballe, M; Scheller, R; Stahl Skov, P

    2003-01-01

    BACKGROUND: The aim of the study was to examine the diagnostic value of skin prick test (SPT), scratch-chamber test (SCT), histamine release (HR) and specific immunoglobulin E (IgE) in birch-allergic patients with oral allergy syndrome to apple. METHODS: Ten birch-allergic patients with oral...... a detailed case history about symptoms of oral allergy syndrome combined with a SPT with fresh apple peel or A72 will be useful....

  7. Interactions of skin thickness and physicochemical properties of test compounds in percutaneous penetration studies

    Wilkinson, Simon C.; Maas, Wilfred J. M.; Nielsen, Jesper Bo

    2006-01-01

    : Percutaneous penetration of caffeine (log P -0.01), testosterone (log P 3.32), propoxur (log P 1.52) (finite dose in ethanol to water vehicle ratio) and butoxyethanol (log P 0.83) (undiluted finite dose or as an infinite dose 50% [v/v] aqueous solution) through skin of varying thicknesses under occluded...... conditions was measured using flow through cells for 8-24 h. Saline (adjusted to pH 7.4) was used as receptor fluid, with BSA added for studies with testosterone and propoxur. Following exposure, the remaining surface dose was removed by swabbing and the skin digested prior to scintillation counting. Results......: The maximum flux of caffeine was increased with decreasing skin thickness, although these differences were found to be non-significant. The presence of caffeine in the skin membrane was not altered by skin thickness. Maximum flux and cumulative dose absorbed of testosterone and butoxyethanol (in both finite...

  8. Skin graft

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  9. Diagnosis of penicillin allergy revisited: the value of case history, skin testing, specific IgE and prolonged challenge.

    Hjortlund, J; Mortz, C G; Skov, P S; Bindslev-Jensen, C

    2013-08-01

    Skin testing in duplicate, correlation between case history of immediate and nonimmediate reactions and challenge outcome and prolonged oral treatment with penicillin in the diagnostic evaluation of allergic reactions to β-lactam antibiotics, mimicking real-life situations, have only been addressed in few studies. A total of 342 patients suspected of having β-lactam allergy were investigated according to the European Network for Drug Allergy (ENDA) guidelines and patients found to be negative in the ENDA program were supplemented with a 7-day oral treatment with penicillin. Skin testing with penicillins was performed in duplicate. Patients with case histories of reactions to other β-lactams were also subsequently challenged with the culprit drug. Nineteen patients were IgE-sensitized to penicillin. Then, intracutaneous tests (ICTs) were performed, in which 35 patients tested positive for allergy, 21 with delayed and 14 with immediate reactions. Only three patients tested positive for the major (PPL) and/or minor (MDM) penicillin determinants, all being positive for penicillin G in ICT. The remaining 291 patients were challenged with penicillin: 10 tested positive in single-dose challenge and 23 tested positive in the 7-day challenge. A total of 17 of 78 patients with a negative penicillin challenge tested positive during challenges with other β-lactams. We found no correlation between case histories of immediate and nonimmediate reactions and reaction time during challenge. The data suggest that case history is often insufficient to discriminate between immediate reactors and nonimmediate reactors. A 7-day challenge with the culprit β-lactam may yield more positive reactions than the accepted one- or 2-day challenge. Interpretation of skin testing should be made with caution. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Safety of the two-step tuberculin skin test in Indian health care workers.

    Christopher, Devasahayam J; Shankar, Deepa; Datey, Ashima; Zwerling, Alice; Pai, Madhukar

    2014-12-01

    Health care workers (HCW) in low and middle income countries are at high risk of nosocomial tuberculosis infection. Periodic screening of health workers for both TB disease and infection can play a critical role in TB infection control. Occupational health programs that implement serial tuberculin skin testing (TST) are advised to use a two-step baseline TST. This helps to ensure that boosting of waned immune response is not mistaken as new TB infection (i.e. conversion). However, there are no data on safety of the two-step TST in the Indian context where HCWs are repeatedly exposed. Nursing students were recruited from 2007 to 2009 at the Christian Medical College and Hospital, Vellore, India. Consenting nursing students were screened with a baseline two-step TST at the time of recruitment. From 2007 to 2008 adverse events were recorded when reported during the TST reading (Cohort A). Nurses recruited in the final study year (2009) answered an investigator administered questionnaire assessing all likely side-effects Cohort B). This information was extracted from the case report forms and analysed. Between 2007 and 09, 800 trainees consented to participate in the annual TB screening study and 779 did not have a past history of TB or recall a positive TST and were selected to administer TST. Of these, 755 returned for reading the result and had complete data and were included for the final analysis - 623 subjects in (cohort A) and 132 in (cohort B). These were included for the final analysis. In cohort A only 1.3% reported adverse events. In cohort B, as per the investigator administered questionnaire; 25% reported minor side effects. Itching and local pain were the most common side effects encountered. There were no major adverse events reported. In particular, the adverse events were similar in the second step of the test and not more severe. Screening of HCWs with two-step TST for LTBI is simple and safe, and hence suitable for wide scale implementation in high

  11. Reel Efektif Döviz Kurunun Durağanlığının Yapısal Kırılmalı Panel Birim Kök Testleri Kullanılarak Sınanması = Analyzing the Stationarity of Reel Effective Exchange Rates Using Panel Unit Root Tests with Structural Breaks

    Ferda YERDELEN TATOĞLU

    2009-06-01

    Full Text Available In the last years, many studies have analyzed the stationarity of reel exchange rates which gives important knowledge about economic stability of countries. The panel unit root tests which include both pooled and individual unit root tests are used frequently to analyze the stationarity of real exchange rates. Generally, structural breaks issue have taken place in macroeconomic time series for some years. If unit root tests are used without taking account these structural breaks, stationarity hypothesis can be rejected mistakenly. In this study, panel unit root tests with and without structural breaks were used to analyze the validity of Purchasing Power Parity hypothesis in 25 OECD countries. According to the results, while in panel unit root tests with no break, PPP theory is valid for only 10 countries; it is valid for all countries in panel unit root tests with structural breaks.

  12. Modeling slug tests in unconfined aquifers with both oscillatory and overdamped responses, and with low-K and high-K skin effects

    Thoma, M. J.; Malama, B.; Barrash, W.; Bohling, G.; Butler, J. J.

    2009-12-01

    We extend the models for slug tests developed by Hyder et al. (1994) and Butler and Zhan (2004) to obtain a single general model for slug tests in unconfined aquifers in partially penetrating wells with a near-well disturbed zone (skin). The full range of responses, oscillatory to overdamped, is considered since both types of responses are common in wells in unconsolidated coarse fluvial aquifers, and others. The general semi-analytical solution allows for skin and formation storage as well as anisotropy in skin and formation hydraulic conductivity (K). The water table is treated as a fixed head boundary so the solution is applicable for wells screened below the water table. The model is validated by comparison with other models and by matching field data from unconfined fluvial aquifers at sites in Nebraska (MSEA) and Idaho (BHRS). We examine the effects of varying skin K and skin thickness to simulate the impact of a near-well disturbed zone that is lower (damage) or higher (filter pack) K than the formation. Results indicate that, for a given set of measured behavior at an example test zone, minor progressive decreases in estimated formation K occur with increases in assumed skin K, and moderate increases in estimated formation K occur with decreases in assumed skin K. Major increases (orders of magnitude) in estimated formation K occur with increased thickness of low-K skin. The importance of incorporating a finite-thickness representation of the skin, rather than the conventional infinitely thin representation, is also addressed.

  13. IgE Sensitization Patterns to Commonly Consumed Foods Determined by Skin Prick Test in Korean Adults

    Kim, Sung Ryeol; Park, Hye Jung; Park, Kyung Hee; Lee, Jae-Hyun; Park, Jung-Won

    2016-01-01

    Offending food allergens can vary with regional preferences in food consumption. In this study, we analysed sensitization rates to commonly consumed foods in Korean adults suspected of having food allergy. One hundred and thirty four subjects underwent a skin prick test (SPT) with 55 food allergens, of which 13 were made by our laboratory and the rest were commercially purchased. Of the 134 patients, 73 (54.5%) were sensitized to one or more food allergens. Sensitization to chrysalis was dete...

  14. Panel Session

    Bertelsen, Olav Wedege

    2004-01-01

    In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach.......In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach....

  15. An evaluation of the diagnostic value of different skin tests with egg in clinically egg-allergic children having atopic dermatitis

    Hansen, Tine K; Høst, Arne; Bindslev-Jensen, Carsten

    2004-01-01

    Skin testing is a common diagnostic procedure in food allergy, but the final diagnosis of food allergy is based on the clinical response to food challenge. We studied the value of the skin prick-prick test (SPT), skin application food test (SAFT) and atopy patch test (APT) with fresh egg extract......-allergic children were positive in SPT and 40-60% in APT. In APT and in SPT false-positive reactions to egg were observed. In this study comprising a small number of patients including control subjects, neither SAFT nor APT with fresh whole egg extract were able to increase the diagnostic accuracy in detecting egg...

  16. Manufacturing and Structural Feasibility of Natural Fiber Reinforced Polymeric Structural Insulated Panels for Panelized Construction

    Nasim Uddin

    2011-01-01

    Full Text Available Natural fibers are emerging in the fields of automobile and aerospace industries to replace the parts such as body panels, seats, and other parts subjected to higher bending strength. In the construction industries, they have the potential to replace the wood and oriented strand boards (OSB laminates in the structural insulated panels (SIPs. They possess numerous advantages over traditional OSB SIPs such as being environmental friendly, recyclable, energy efficient, inherently flood resistant, and having higher strength and wind resistance. This paper mainly focuses on the manufacturing feasibility and structural characterization of natural fiber reinforced structural insulated panels (NSIPs using natural fiber reinforced polymeric (NFRP laminates as skin. To account for the use of natural fibers, the pretreatments are required on natural fibers prior to use in NFRP laminates, and, to address this issue properly, the natural fibers were given bleaching pretreatments. To this end, flexure test and low-velocity impact (LVI tests were carried out on NSIPs in order to evaluate the response of NSIPs under sudden impact loading and uniform bending conditions typical of residential construction. The paper also includes a comparison of mechanical properties of NSIPs with OSB SIPs and G/PP SIPs. The results showed significant increase in the mechanical properties of resulting NSIP panels mainly a 53% increase in load-carrying capacity compared to OSB SIPs. The bending modulus of NSIPs is 190% higher than OSB SIPs and 70% weight reduction compared to OSB SIPs.

  17. Occurrence of sea spider Endeis mollis Carpenter (Arthropoda: Pycnogonida on the test panels submerged in Gulf of Mannar, southeast coast of India

    S. Satheesh

    2012-06-01

    Full Text Available Sea spiders (Pycnogonids are exclusively marine arthropods with worldwide distribution. Pycnogonida remains one of the poorly investigated groups encountered in fouling communities. In the present study, distribution pycnogonid species Endeis mollis associated with the fouling community developed on test panels submerged at Kudankulam coast, Gulf of Mannar was studied for a period of two years. Throughout the period of investigation, Endeis mollis was observed on the test panels. A maximum of 55 individuals per square dm was observed during pre-monsoon season and a minimum of 9 individuals per square dm during monsoon season. Results of this study on seasonal distribution are of considerable interest because so little has been documented on the ecology of Pycnogonids in India.

  18. Testing the Causal Links between School Climate, School Violence, and School Academic Performance: A Cross-Lagged Panel Autoregressive Model

    Benbenishty, Rami; Astor, Ron Avi; Roziner, Ilan; Wrabel, Stephani L.

    2016-01-01

    The present study explores the causal link between school climate, school violence, and a school's general academic performance over time using a school-level, cross-lagged panel autoregressive modeling design. We hypothesized that reductions in school violence and climate improvement would lead to schools' overall improved academic performance.…

  19. Full-scale testing of infilled steel frames with precast concrete panels provided with a window opening

    Teeuwen, P.A; Kleinman, C.S.; Snijder, H.H.; Hofmeyer, H.

    2008-01-01

    As an alternative to conventional structures for tall buildings, a hybrid lateral load resisting building system has been designed, enabling the assembly of tall buildings directly from truck. It consists of steel frames with discretely connected precast concrete infill panels provided with a window

  20. Deconstructing the education-innovation-development nexus in the EU-28 using panel causality and poolability tests

    Makkonen, Teemu; Mitze, Timo Friedel

    2018-01-01

    We apply panel econometrics to assess the causal linkages between education, research and innovation (R&I) and economic development for EU-28 countries over the time period 1998–2013. Since this period coincides with the biggest enlargement wave in the EU’s history, we particularly aim at identif...

  1. Proposal of abolition of the skin sensitivity test before equine rabies immune globulin application

    CUPO Palmira

    2001-01-01

    Full Text Available An epizootic outbreak of rabies occurred in 1995 in Ribeirão Preto, SP, with 58 cases of animal rabies (54 dogs, 3 cats and 1 bat confirmed by the Pasteur Institute of São Paulo, and one human death. The need to provide care to a large number of people for the application of equine rabies immune globulin (ERIG prevented the execution of the skin sensitivity test (SST and often also the execution of desensitization, procedures routinely used up to that time at the Emergency Unit of the University Hospital of the Faculty of Medicine of Ribeirão Preto, University of São Paulo (EU-UHFMRP-USP, a reference hospital for the application of heterologous sera. In view of our positive experience of several years with the abolition of SST and of the use of premedication before the application of antivenom sera, we used a similar schedule for ERIG application. Of the 1489 victims of animal bites, 1054 (71% received ERIG; no patient was submitted to SST and all received intravenously anti-histamines (anti-H1 + anti-H2 and corticosteroids before the procedure. The patients were kept under observation for 60 to 180 minutes and no adverse reaction was observed. On the basis of these results, since December 1995 ERIG application has been decentralized in Ribeirão Preto and has become the responsibility of the Emergency Unit of the University Hospital and the Central Basic Health Unit, where the same routine is used. Since then, 4216 patients have received ERIG (1818 at the Basic Health Unit and 2398 at the EU-UHFMRP, with no problems. The ideal would be the routine use of human rabies immune globulin (HRIG in public health programs, but this is problematic, because of their high cost. However, while this does not occur, the use of SST is no longer justified at the time of application of ERIG, in view of the clinical evidence of low predictive value and low sensitivity of SST involving the application of heterologous sera. It is very important to point out

  2. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Cha, Bo Kyung; Jeon, Seongchae; Seo, Chang-Woo

    2016-01-01

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd_2O_2S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  3. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Cha, Bo Kyung, E-mail: goldrain99@kaist.ac.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiological Science, Yonsei University, Gangwon-do 220-710 (Korea, Republic of)

    2016-09-21

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  4. No evidence that protein truncating variants in BRIP1 are associated with breast cancer risk: implications for gene panel testing

    Easton, Douglas Frederick; Lesueur, Fabienne; Decker, Brennan; Michailidou, Kyriaki; Li, Jun; Allen, Jamie; Luccarini, Craig; Pooley, Karen Anne; Shah, Mitulkumar Nandlal; Bolla, Manjeet K; Wang, Qin; Dennis, Joe; Ahmad, Jamil; Thompson, Ella R; Damiola, Francesca

    2016-01-01

    Background BRCA1 interacting protein C-terminal helicase 1 (BRIP1) is one of the Fanconi Anaemia Complementation (FANC) group family of DNA repair proteins. Biallelic mutations in BRIP1 are responsible for FANC group J, and previous studies have also suggested that rare protein truncating variants in BRIP1 are associated with an increased risk of breast cancer. These studies have led to inclusion of BRIP1 on targeted sequencing panels for breast cancer risk prediction. Metho...

  5. Two-step rating-based 'double-faced applicability' test for sensory analysis of spread products as an alternative to descriptive analysis with trained panel.

    Kim, In-Ah; den-Hollander, Elyn; Lee, Hye-Seong

    2018-03-01

    Descriptive analysis with a trained sensory panel has thus far been the most well defined methodology to characterize various products. However, in practical terms, intensive training in descriptive analysis has been recognized as a serious defect. To overcome this limitation, various novel rapid sensory profiling methodologies have been suggested in the literature. Among these, attribute-based methodologies such as check-all-that-apply (CATA) questions showed results comparable to those of conventional sensory descriptive analysis. Kim, Hopkinson, van Hout, and Lee (2017a, 2017b) have proposed a novel attribute-based methodology termed the two-step rating-based 'double-faced applicability' test with a novel output measure of applicability magnitude (d' A ) for measuring consumers' product usage experience throughout various product usage stages. In this paper, the potential of the two-step rating-based 'double-faced applicability' test with d' A was investigated as an alternative to conventional sensory descriptive analysis in terms of sensory characterization and product discrimination. Twelve commercial spread products were evaluated using both conventional sensory descriptive analysis with a trained sensory panel and two-step rating-based 'double-faced applicability' test with an untrained sensory panel. The results demonstrated that the 'double-faced applicability' test can be used to provide a direct measure of the applicability magnitude of sensory attributes of the samples tested in terms of d' A for sensory characterization of individual samples and multiple sample comparisons. This suggests that when the appropriate list of attributes to be used in the questionnaire is already available, the two-step rating-based 'double-faced applicability' test with d' A can be used as a more efficient alternative to conventional descriptive analysis, without requiring any intensive training process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Field Method for Testing Repellency of an Icaridin-Containing Skin Lotion against Vespid Wasps

    Jean-Luc Boevé

    2016-06-01

    Full Text Available Vespid wasps are ecologically beneficial predators of insects but their stings also pose a human health risk. Current control methods based on killing vespids are suboptimal. Here, the repellent effect against Vespula vulgaris of a 20% icaridin skin lotion was evaluated under field conditions. An experimental setup was designed in which six artificial skin pieces (10 × 10 cm were video-recorded for 1 h, to count each min the numbers of flying and feeding vespids. Prior to monitoring, five pieces were successively smeared with 2 mg of cream per cm2, in 30 min intervals, from t = −120 min to 0. The sixth sheet remained untreated to serve as a control. One milliliter of an attractant, fruit jam, was deposited on each of the six surfaces at t = 0. The control surface was free of any flying or feeding vespid during an average period of 25 min, whereas the other five surfaces (treated at t = −120, −90, −60, −30, and 0 min remained vespid-free for 39, 40, 45, 49, and 51 min, respectively. The skin lotion remained significantly active for at least 2 h. The experimental methodology is adjustable and allows the study of repellents against vespids in semi-natural conditions.

  7. Comparison of the skin sensitizing potential of unsaturated compounds as assessed by the murine local lymph node assay (LLNA) and the guinea pig maximization test (GPMT).

    Kreiling, R; Hollnagel, H M; Hareng, L; Eigler, D; Lee, M S; Griem, P; Dreessen, B; Kleber, M; Albrecht, A; Garcia, C; Wendel, A

    2008-06-01

    The skin sensitization potential of eight unsaturated and one saturated lipid (bio)chemicals was tested in both the LLNA and the GPMT to address the hypothesis that chemicals with unsaturated carbon-carbon double bonds may result in a higher number of unspecific (false positive) results in the LLNA compared to the GPMT. Seven substances (oleic acid, linoleic acid, linolenic acid, undecylenic acid, maleic acid, squalene and octinol) gave clear positive results in the LLNA (stimulation index (SI)> or = 3) and thus would require labelling as skin sensitizer. Fumaric acid and succinic acid gave clearly negative results. In the GPMT, besides some sporadic skin reactions, reproducible skin reactions indicating an allergic response were found in a few animals for four test substances. Based on the GPMT results, only undecylenic acid would have to be classified and labelled as a skin sensitizer according to the European Dangerous Substance Directive (67/548/EEC) (results for linoleic acid were inconclusive), while the other seven test substances would not require labelling. Possible mechanisms for unspecific skin cell stimulation and lymph node responses are discussed. In conclusion, the suitability of the LLNA for unsaturated compounds bearing structural similarity to the tested substances should be carefully considered and the GPMT should remain available as an accepted test method for skin sensitization hazard identification.

  8. Skin Diseases: Skin Health and Skin Diseases

    Skip Navigation Bar Home Current Issue Past Issues Skin Diseases Skin Health and Skin Diseases Past Issues / Fall 2008 Table of Contents ... acne to wrinkles Did you know that your skin is the largest organ of your body? It ...

  9. Safety and efficacy of the C-Tb skin test to diagnose Mycobacterium tuberculosis infection, compared with an interferon γ release assay and the tuberculin skin test: a phase 3, double-blind, randomised, controlled trial.

    Ruhwald, Morten; Aggerbeck, Henrik; Gallardo, Rafael Vázquez; Hoff, Søren T; Villate, José I; Borregaard, Bettine; Martinez, José A; Kromann, Ingrid; Penas, Antón; Anibarro, Luis L; de Souza-Galvão, Maria Luiza; Sánchez, Francisca; Rodrigo-Pendás, Jose Ángel; Noguera-Julian, Antoni; Martínez-Lacasa, Xavier; Tuñez, Maria Victoria; Fernández, Virginia Leiro; Millet, Joan P; Moreno, Antonio; Cobos, Nazaret; Miró, José M; Roldan, Llanos; Orcau, Angels; Andersen, Peter; Caylá, Joan A

    2017-04-01

    Targeted screening and treatment of Mycobacterium tuberculosis infection substantially reduces the risk of developing active tuberculosis. C-Tb (Statens Serum Institute, Copenhagen, Denmark) is a novel specific skin test based on ESAT-6 and CFP10 antigens. We investigated the safety and diagnostic potential of C-Tb compared with established tests in the contact-tracing setting. Negative controls, close contacts, occasional contacts, and patients with active pulmonary tuberculosis were enrolled at 13 centres in Spain. We compared C-Tb with the QuantiFERON-TB Gold In-Tube ([QFT] Qiagen, Hilden, Germany) interferon γ release assay (IGRA) and the purified protein derivative (PPD) RT 23 tuberculin skin test ([TST] Statens Serum Institute). All participants older than 5 years were tested with QFT. Some participants in the negative control group received C-Tb without the TST to test for potential interactions between C-Tb and PPD RT 23. The rest were randomly assigned in blocks of ten and tested with both C-Tb and TST, with five in each block receiving injection of C-Tb in the right arm and the TST in the left arm and five vice versa. The primary and safety analyses were done in all participants randomly assigned to a group who received any test. This trial is registered with ClinicalTrials.gov, number NCT01631266, and with EudraCT, number 2011-005617-36. From July 24, 2012, to Oct 2, 2014, 979 participants were enrolled, of whom 263 were negative controls, 299 were occasional contacts, 316 were close contacts, and 101 were patients with tuberculosis. 970 (99%) participants completed the trial. Induration sizes were similar for C-Tb and TST, but TST positivity was affected by BCG vaccination status. We found a strong positive trend towards C-Tb test positivity with increasing risk of infection, from 3% in negative controls to 16% in occasional contacts, to 43% in close contacts. C-Tb and QFT results were concordant in 785 (94%) of 834 participants aged 5 years and older

  10. Screening health care workers with interferon-γ release assay versus tuberculin skin test: impact on costs and adherence to testing (the SWITCH study).

    Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward

    2012-07-01

    To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.

  11. High temperature structural sandwich panels

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several

  12. Skin sensitisation--moving forward with non-animal testing strategies for regulatory purposes in the EU.

    Basketter, David; Alépée, Nathalie; Casati, Silvia; Crozier, Jonathan; Eigler, Dorothea; Griem, Peter; Hubesch, Bruno; de Knecht, Joop; Landsiedel, Robert; Louekari, Kimmo; Manou, Irene; Maxwell, Gavin; Mehling, Annette; Netzeva, Tatiana; Petry, Thomas; Rossi, Laura H

    2013-12-01

    In a previous EPAA-Cefic LRI workshop in 2011, issues surrounding the use and interpretation of results from the local lymph node assay were addressed. At the beginning of 2013 a second joint workshop focused greater attention on the opportunities to make use of non-animal test data, not least since a number of in vitro assays have progressed to an advanced position in terms of their formal validation. It is already recognised that information produced from non-animal assays can be used in regulatory decision-making, notably in terms of classifying a substance as a skin sensitiser. The evolution into a full replacement for hazard identification, where the decision is not to classify, requires the generation of confidence in the in vitro alternative, e.g. via formal validation, the existence of peer reviewed publications and the knowledge that the assay(s) are founded on key elements of the Adverse Outcome Pathway for skin sensitisation. It is foreseen that the validated in vitro assays and relevant QSAR models can be organised into formal testing strategies to be applied for regulatory purposes by the industry. To facilitate progress, the European Partnership for Alternative Approaches to animal testing (EPAA) provided the platform for cross-industry and regulatory dialogue, enabling an essential and open debate on the acceptability of an in vitro based integrated strategy. Based on these considerations, a follow up activity was agreed upon to explore an example of an Integrated Testing Strategy for skin sensitisation hazard identification purposes in the context of REACH submissions. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. The challenge of producing skin test antigens with minimal resources suitable for human application against a neglected tropical disease; leprosy.

    Becky L Rivoire

    Full Text Available True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan and MLCwA (M. leprae cell wall antigens. In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.

  14. The challenge of producing skin test antigens with minimal resources suitable for human application against a neglected tropical disease; leprosy.

    Rivoire, Becky L; TerLouw, Stephen; Groathouse, Nathan A; Brennan, Patrick J

    2014-01-01

    True incidence of leprosy and its impact on transmission will not be understood until a tool is available to measure pre-symptomatic infection. Diagnosis of leprosy disease is currently based on clinical symptoms, which on average take 3-10 years to manifest. The fact that incidence, as defined by new case detection, equates with prevalence, i.e., registered cases, suggests that the cycle of transmission has not been fully intercepted by implementation of multiple drug therapy. This is supported by a high incidence of childhood leprosy. Epidemiological screening for pre-symptomatic leprosy in large endemic populations is required to facilitate targeted chemoprophylactic interventions. Such a test must be sensitive, specific, simple to administer, cost-effective, and easy to interpret. The intradermal skin test method that measures cell-mediated immunity was explored as the best option. Prior knowledge on skin testing of healthy subjects and leprosy patients with whole or partially fractionated Mycobacterium leprae bacilli, such as Lepromin or the Rees' or Convit' antigens, has established an acceptable safety and potency profile of these antigens. These data, along with immunoreactivity data, laid the foundation for two new leprosy skin test antigens, MLSA-LAM (M. leprae soluble antigen devoid of mycobacterial lipoglycans, primarily lipoarabinomannan) and MLCwA (M. leprae cell wall antigens). In the absence of commercial interest, the challenge was to develop these antigens under current good manufacturing practices in an acceptable local pilot facility and submit an Investigational New Drug to the Food and Drug Administration to allow a first-in-human phase I clinical trial.

  15. Lipid Panel

    ... A routine cardiac risk assessment typically includes a fasting lipid panel. Beyond that, research continues into the usefulness of other non-traditional markers of cardiac risk, such as Lp-PLA 2 . A health practitioner may choose to evaluate one or more ...

  16. Evaluation of the effect of Dardia Lipo Line on skin inflammation induced by surfactants using the repeated open-application test.

    Ortonne, J-P; Queille-Roussel, C

    2007-09-01

    Medical skin care products are topical preparations with mainly moisturizing properties. A new line of medical skin products with an excellent tolerability profile and improved hydration for dry skin has been developed, but beneficial effects have not yet been investigated on damaged skin. To investigate if these products maintain barrier function and hydration status, improve subjective symptoms due to irritant contact dermatitis and to prove their tolerability on damaged skin. Single-centre, blinded, randomized, controlled study in 20 healthy Caucasian women. 5% sodium lauryl sulphate solution was used to induce skin irritation. Two sites on the inside surface of both forearms of each subject were treated daily for 5 days (irritation period). Lipo Cream, Lipo Milk (water-in-oil emulsions) and Lipo Ointment (water-free formulation) were applied twice daily to three of the four test sites on days 1-5. The fourth site was used as a control. Visual readings, subjective symptom assessments, transepidermal water loss (TEWL) and colorimetric measurements, corneometry and skin microrelief macrophotographies were done on days 1-6. On day 6, TEWL was increased vs baseline on all sites; however, TEWL with Lipo Cream or Lipo Ointment was significantly lower than control. At day 6, skin capacitance was 94%, 100% and 85% of baseline value for the cream, milk and ointment, respectively, versus 72% for control. All test products were well tolerated. Lipo Line products showed both protective properties against epidermal dysfunction and significant hydrating effect.

  17. Development and Validation of a Serologic Test Panel for Detection of Powassan Virus Infection in U.S. Patients Residing in Regions Where Lyme Disease Is Endemic.

    Thomm, Angela M; Schotthoefer, Anna M; Dupuis, Alan P; Kramer, Laura D; Frost, Holly M; Fritsche, Thomas R; Harrington, Yvette A; Knox, Konstance K; Kehl, Sue C

    2018-01-01

    Powassan virus (POWV) is an emerging tick-borne arbovirus presenting a public health threat in North America. POWV lineage II, also known as deer tick virus, is the strain of the virus most frequently found in Ixodes scapularis ticks and is implicated in most cases of POWV encephalitis in the United States. Currently, no commercial tests are available to detect POWV exposure in tick-borne disease (TBD) patients. We describe here the development and analytical validation of a serologic test panel to detect POWV infections. The panel uses an indirect enzyme immunoassay (EIA) to screen. EIA-positive samples reflex to a laboratory-developed, POWV-specific immunofluorescence assay (IFA). The analytical sensitivity of the test panel was 89%, and the limit of detection was a plaque reduction neutralization test (PRNT) titer of 1:20. The analytical specificity was 100% for the IgM assay and 65% for the IgG assay when heterologous-flavivirus-positive samples were tested. On samples collected from regions where Lyme disease is endemic, seroprevalence for POWV in TBD samples was 9.4% (10 of 106) versus 2% when tested with non-TBD samples (2 of 100, P = 0.034). No evidence of POWV infection was seen in samples collected from a region where Lyme disease was not endemic (0 of 22). This test panel provides a sensitive and specific platform for detecting a serologic response to POWV early in the course of infection when neutralizing antibodies may not be detectable. Combined with clinical history, the panel is an effective tool for identifying acute POWV infection. IMPORTANCE Approximately 100 cases of POWV disease were reported in the United States over the past 10 years. Most cases have occurred in the Northeast (52) and Great Lakes (45) regions (https://www.cdc.gov/powassan/statistics.html). The prevalence of POWV in ticks and mammals is increasing, and POWV poses an increasing threat in a greater geographical range. In areas of the Northeast and Midwest where Lyme disease is

  18. Clinical evaluation of MPT-64 and MPT-59, two proteins secreted from Mycobacterium tuberculosis, for skin test reagents

    Wilcke, J T; Jensen, B N; Ravn, P

    1996-01-01

    and one healthy bacille Calmette-Guérin vaccinated subject without patient contact) reacted to MPT-64. The studies of cell proliferation and induction of interferon-gamma (IFN-gamma) following stimulation with tuberculin PPD and MPT-64 supported this profile of reactivity. CONCLUSION: None...... of the experimental skin test antigens had properties superior to tuberculin PPD RT23 in humans. The failure of MPT-64 to induce delayed type hypersensitivity reactions in the majority of tuberculosis patients is discussed, in view of the potent reactivity to MPT-64 in tuberculous guinea pigs....

  19. Comparison of Tuberculin Skin Test result and interferon gamma response to human PPD in BCG scar positive and negative children.

    Sayyahfar, Shirin; Karimi, Abdollah; Fahimzad, Alireza; Shamshiri, Ahmad Reza

    2014-03-01

    The aim of this study is to compare Tuberculin Skin Test (TST) result and interferon gamma response to human PPD (purified protein derivative), in scar positive and scar negative BCG-vaccinated children. Between August 2007 and May 2008 a total of 236 children aged 1-168 months (mean 21 months) admitted to Mofid Children's Hospital, Tehran, Iran, were enrolled in a cross-sectional study. Each patient was examined for BCG vaccine scar and tested with TST and human PPD-based Interferon Gamma Release Assay (IGRA). Two hundred and twenty one cases out of 236 (44% female, 1-168 months, mean age 21 months) were scar positive of whom 95% TST result was negative. Human PPD-based IGRA was positive in 110 (49.8%), negative in 85 (38.4 %) and indeterminate in 26 (11.8%) of scar positive patients. Fifteen children (40% female, 1-156 months; mean age 42 months) were scar negative. All the scar negative cases were TST negative. Human PPD-based IGRA was positive in 10 (66.7%), negative in 4 (26.7%) and indeterminate in 1 (6.7%) of scar negative patients. Immune responsiveness to human PPD antigens in scar positive and negative children may not correspond with results of the Tuberculin Skin Test. Copyright © 2013 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  20. Natural evolution of skin-test sensitivity in patients with IgE-mediated hypersensitivity to cephalosporins.

    Romano, A; Gaeta, F; Valluzzi, R L; Zaffiro, A; Caruso, C; Quaratino, D

    2014-06-01

    There are studies demonstrating that skin-test sensitivity to penicillins can decrease over time and that allergic patients may lose sensitivity if the responsible compounds are avoided. With regard to subjects with IgE-mediated hypersensitivity to cephalosporins, however, such studies are lacking. We evaluated prospectively in a 5-year follow-up 72 cephalosporin-allergic patients. After the first evaluation, patients were classified into two groups according to their patterns of allergologic-test positivity: to both penicillins and cephalosporins (group A), or only to cephalosporins (group B). Skin tests and serum-specific IgE assays were repeated 1 year later and, in case of persistent positivity, 3 and 5 years after the first allergologic examination. Seven (43.7%) of the 16 subjects of group A and 38 (67.8%) of the 56 patients of group B became negative; one was lost to follow-up. Patients of group B became negative sooner and more frequently than group A subjects. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Use of a smart phone based thermo camera for skin prick allergy testing: a feasibility study (Conference Presentation)

    Barla, Lindi; Verdaasdonk, Rudolf M.; Rustemeyer, Thomas; Klaessens, John; van der Veen, Albert

    2016-02-01

    Allergy testing is usually performed by exposing the skin to small quantities of potential allergens on the inner forearm and scratching the protective epidermis to increase exposure. After 15 minutes the dermatologist performs a visual check for swelling and erythema which is subjective and difficult for e.g. dark skin types. A small smart phone based thermo camera (FLIR One) was used to obtain quantitative images in a feasibility study of 17 patients Directly after allergen exposure on the forearm, thermal images were captured at 30 seconds interval and processed to a time lapse movie over 15 minutes. Considering the 'subjective' reading of the dermatologist as golden standard, in 11/17 pts (65%) the evaluation of dermatologist was confirmed by the thermo camera including 5 of 6 patients without allergic response. In 7 patients thermo showed additional spots. Of the 342 sites tested, the dermatologist detected 47 allergies of which 28 (60%) were confirmed by thermo imaging while thermo imaging showed 12 additional spots. The method can be improved with user dedicated acquisition software and better registration between normal and thermal images. The lymphatic reaction seems to shift from the original puncture site. The interpretation of the thermal images is still subjective since collecting quantitative data is difficult due to motion patient during 15 minutes. Although not yet conclusive, thermal imaging shows to be promising to improve the sensitivity and selectivity of allergy testing using a smart phone based camera.

  2. Freqüência de positividade em teste cutâneo para aeroalérgenos Frequency of positive skin tests for airborne allergic agents

    Ricardo Godinho

    2003-12-01

    Full Text Available O aumento da prevalência das rinopatias tem sido descrito na literatura médica e a rinite alérgica continua sendo a mais freqüente. O teste cutâneo é importante no diagnóstico diferencial das doenças nasais e na determinação do padrão de sensibilização da população. Esta permite a promoção de medidas de redução de exposição, sendo fundamental para o tratamento adequado da rinite alérgica. FORMA DE ESTUDO: Coorte transversal. MATERIAL E MÉTODO: Com o objetivo de determinar a freqüência de positividade no teste cutâneo para aeroalérgenos específicos, avaliamos os prontuários de 398 pacientes com sintomas nasais sugestivos de alergia ou outras queixas otorrinolaringológicas que necessitavam deste teste para esclarecimento diagnóstico. RESULTADOS: A poeira doméstica (74,9%, o dermatofagóide (58,4% e o mofo (36,5% foram os alérgenos mais freqüentes, seguidos do pêlo de cão (32,7%, gramínea (22,4%, pêlo de gato (16,9%, penas (16,4% e lã (15,6%. Apenas 3,5% com positividade para pena de periquito e 1,5% para flores. 39 pacientes (9,8% apresentaram teste cutâneo negativo, 10 (2,5% apresentaram reação ao extrato da solução e 8 (2% não reagiram à histamina. Não foram encontradas complicações à aplicação do teste. CONCLUSÃO: A poeira doméstica foi o aeroalérgeno mais freqüente. Os testes cutâneos devem ser realizados no contexto da história clínica e os resultados apresentados nos orientam para o adequado diagnóstico e tratamento das rinopatias.Medical literature has reported on the increase in the prevalence of nose diseases, and allergic rhinitis still leads the statistics. The skin test is important in the differential diagnosis of nose diseases and to determine the sensitivity pattern of the population in order to establish measures to reduce exposure. This is fundamental for adequate handling allergic rhinitis. STUDY DESIGN: Transversal cohorte. MATERIAL AND METHOD: In order to determine the

  3. Local lymph node assay (LLNA): comparison of different protocols by testing skin-sensitizing epoxy resin system components.

    Gamer, Armin O; Nies, Eberhard; Vohr, Hans-Werner

    2008-12-01

    Thirteen epoxy resin system components were tested in the LLNA with regard to their sensitizing potency. Lymph node stimulation was quantified not only by measuring the incorporation of [3H]-thymidine into the ear lymph nodes but also the counts of cells recovered from these organs. Equivalent figures were obtained with both endpoints used for the evaluation of lymph node cell proliferation if the reference stimulation indices were adjusted. When dissolved in acetone, all test substances showed skin-sensitizing potential, mainly on the boundary between "strong" and "moderate" according to common potency evaluation schemes. Replacing acetone with acetone/olive oil (4:1) as a vehicle for four selected test items, resulted in considerably lower estimated concentrations for sensitization induction. The challenges in comparing the results obtained by different LLNA variations are discussed.

  4. Non-Destructive Inspection of Impact Damage in Composite Aircraft Panels by Ultrasonic Guided Waves and Statistical Processing

    Margherita Capriotti

    2017-06-01

    Full Text Available This paper discusses a non-destructive evaluation (NDE technique for the detection of damage in composite aircraft structures following high energy wide area blunt impact (HEWABI from ground service equipment (GSE, such as heavy cargo loaders and other heavy equipment. The test structures typically include skin, co-cured stringers, and C-frames that are bolt-connected onto the skin with shear ties. The inspection exploits the waveguide geometry of these structures by utilizing ultrasonic guided waves and a line scan approach. Both a contact prototype and a non-contact prototype were developed and tested on realistic test panels subjected to impact in the laboratory. The results are presented in terms of receiver operating characteristic curves that show excellent probability of detection with low false alarm rates for defects located in the panel skin and stringers.

  5. Non-Destructive Inspection of Impact Damage in Composite Aircraft Panels by Ultrasonic Guided Waves and Statistical Processing.

    Capriotti, Margherita; Kim, Hyungsuk E; Scalea, Francesco Lanza di; Kim, Hyonny

    2017-06-04

    This paper discusses a non-destructive evaluation (NDE) technique for the detection of damage in composite aircraft structures following high energy wide area blunt impact (HEWABI) from ground service equipment (GSE), such as heavy cargo loaders and other heavy equipment. The test structures typically include skin, co-cured stringers, and C-frames that are bolt-connected onto the skin with shear ties. The inspection exploits the waveguide geometry of these structures by utilizing ultrasonic guided waves and a line scan approach. Both a contact prototype and a non-contact prototype were developed and tested on realistic test panels subjected to impact in the laboratory. The results are presented in terms of receiver operating characteristic curves that show excellent probability of detection with low false alarm rates for defects located in the panel skin and stringers.

  6. A comparative evaluation of in vitro skin sensitisation tests: the human cell-line activation test (h-CLAT) versus the local lymph node assay (LLNA).

    Ashikaga, Takao; Sakaguchi, Hitoshi; Sono, Sakiko; Kosaka, Nanae; Ishikawa, Makie; Nukada, Yuko; Miyazawa, Masaaki; Ito, Yuichi; Nishiyama, Naohiro; Itagaki, Hiroshi

    2010-08-01

    We previously developed the human cell-line activation test (h-CLAT) in vitro skin sensitisation test, based on our reported finding that a 24-hour exposure of THP-1 cells (a human monocytic leukaemia cell line) to sensitisers is sufficient to induce the augmented expression of CD86 and CD54. The aim of this study is to confirm the predictive value of h-CLAT for skin sensitisation activity by employing a larger number of test chemicals. One hundred chemicals were selected, according to their categorisation in the local lymph node assay (LLNA), as being: extreme, strong, moderate and weak sensitisers, and non-sensitisers. The correlation of the h-CLAT results with the LLNA results was 84%. There were some false negatives (e.g. benzoyl peroxide, hexyl cinnamic aldehyde) and some false positives (e.g. 1-bromobutane, diethylphthalate). Eight out of the 9 false negatives (89%) were water-insoluble chemicals. The h-CLAT could positively predict not only extreme and strong sensitisers, but also moderate and weak sensitisers, though the detection rates of weak sensitisers and non-sensitisers were comparatively low. Some sensitisers enhanced both CD86 and CD54 levels, and some enhanced the level of only one of them. The use of the combination of CD86 and CD54 induction as a positive indicator, improved the accuracy of the test. In conclusion, the h-CLAT is expected to be a useful cell-based in vitro method for predicting skin sensitisation potential. 2010 FRAME.

  7. Panel discussion

    Anon.

    1980-01-01

    The panel discussion at the 10th Allianz Forum on 'Technology and Insurance' dealt with the following topics: New technologies: energy conversion (coal, petroleum, natural gas, nuclear energy, solar energy); infrastructure (transport, data processing); basic products (metallic materials, chemical products, pharmaceutical products); integrated products (microprocessors, production line machines) as well as new risks: political; general economic (financing, market structure); insurance-related, dangers to persons and property; reduction of risks. (orig.) [de

  8. Private sector tuberculosis prevention in the US: Characteristics associated with interferon-gamma release assay or tuberculin skin testing.

    Stockbridge, Erica L; Miller, Thaddeus L; Carlson, Erin K; Ho, Christine

    2018-01-01

    To determine whether latent tuberculosis infection risk factors are associated with an increased likelihood of latent tuberculosis infection testing in the US private healthcare sector. A national sample of medical and pharmacy claims representing services rendered January 2011 through December 2013 for 3,997,986 commercially insured individuals in the US who were 0 to 64 years of age. We used multivariable logistic regression models to determine whether TB/LTBI risk factors were associated with an increased likelihood of Interferon-Gamma Release Assay (IGRA) or Tuberculin Skin Test (TST) testing in the private sector. 4.31% (4.27-4.34%) received at least one TST/IGRA test between 2011 and 2013 while 1.69% (1.67-1.72%) received a TST/IGRA test in 2013. Clinical risk factors associated with a significantly increased likelihood of testing included HIV, immunosuppressive therapy, exposure to tuberculosis, a history of tuberculosis, diabetes, tobacco use, end stage renal disease, and alcohol use disorder. Other significant variables included gender, age, asthma, the state tuberculosis rate, population density, and percent of foreign-born persons in a county. Private sector TST/IGRA testing is not uncommon and testing varies with clinical risk indicators. Thus, the private sector can be a powerful resource in the fight against tuberculosis. Analyses of administrative data can inform how best to leverage private sector healthcare toward tuberculosis prevention activities.

  9. Approach/avoidance motivation, message framing and skin cancer prevention: a test of the congruency hypothesis.

    Hevey, David; Dolan, Michelle

    2014-08-01

    The congruency hypothesis posits that approach-orientated individuals are persuaded to engage in prevention behaviours by positively framed messages; conversely, negatively framed messages are more persuasive in encouraging those who are avoidance-orientated. A 2 (frame: loss vs gain) × 2 (motivation: avoidance vs approach) design examined the effects of skin cancer information on sun-protective intentions and free sunscreen sample requests among 533 young adults. Gain-framed messages had the strongest effect on sun-protective intentions for approach-oriented individuals, whereas loss-framed messages had the strongest effect on avoidance-oriented individuals. Message framing effects on precautionary sun behaviour intentions were moderated by motivational differences. © The Author(s) 2013.

  10. Investigation on Wall Panel Sandwiched With Lightweight Concrete

    Lakshmikandhan, K. N.; Harshavardhan, B. S.; Prabakar, J.; Saibabu, S.

    2017-08-01

    The rapid population growth and urbanization have made a massive demand for the shelter and construction materials. Masonry walls are the major component in the housing sector and it has brittle characteristics and exhibit poor performance against the uncertain loads. Further, the structure requires heavier sections for carrying the dead weight of masonry walls. The present investigations are carried out to develop a simple, lightweight and cost effective technology for replacing the existing wall systems. The lightweight concrete is developed for the construction of sandwich wall panel. The EPS (Expanded Polystyrene) beads of 3 mm diameter size are mixed with concrete and developed a lightweight concrete with a density 9 kN/m3. The lightweight sandwich panel is cast with a lightweight concrete inner core and ferrocement outer skins. This lightweight wall panel is tested for in-plane compression loading. A nonlinear finite element analysis with damaged plasticity model is carried out with both material and geometrical nonlinearities. The experimental and analytical results were compared. The finite element study predicted the ultimate load carrying capacity of the sandwich panel with reasonable accuracy. The present study showed that the lightweight concrete is well suitable for the lightweight sandwich wall panels.

  11. Measurement of shear strength resistance in flexion test on PUR sandwich panels: analysis of difficulties and finite element method simulation

    J. M. Chillón Moreno

    2017-09-01

    Full Text Available The use of the composite construction elements combining different materials with complementary characteristics, it has spread increasingly. The sandwich panels composed by external metallic sheets that they contributes resistance and core of rigid insulating thermal foam, that provides qualities that improve the thermal comfort inside all kinds of constructions. They are in use in closings and covers that shape the surrounding one of the buildings. Of the different quality controls to which they have to surrender. In this article one proposes an improvement to the indicated one in the procedure for the determination of the resistance to the shear strength, Managing to avoid many anomalous results obtained by the utilization of rigid plates in the supports. Finally, so much the problem observed as the proposed solution, they are modeled and simulate by means of the method of finite elements.

  12. Advanced solar panel designs

    Ralph, E. L.; Linder, E.

    1995-01-01

    This paper describes solar cell panel designs that utilize new hgih efficiency solar cells along with lightweight rigid panel technology. The resulting designs push the W/kg and W/sq m parameters to new high levels. These new designs are well suited to meet the demand for higher performance small satellites. This paper reports on progress made on two SBIR Phase 1 contracts. One panel design involved the use of large area (5.5 cm x 6.5 cm) GaAs/Ge solar cells of 19% efficiency combined with a lightweight rigid graphite fiber epoxy isogrid substrate configuration. A coupon (38 cm x 38 cm) was fabricated and tested which demonstrated an array specific power level of 60 W/kg with a potential of reaching 80 W/kg. The second panel design involved the use of newly developed high efficiency (22%) dual junction GaInP2/GaAs/Ge solar cells combined with an advanced lightweight rigid substrate using aluminum honeycomb core with high strength graphite fiber mesh facesheets. A coupon (38 cm x 38 cm) was fabricated and tested which demonstrated an array specific power of 105 W/kg and 230 W/sq m. This paper will address the construction details of the panels and an a analysis of the component weights. A strawman array design suitable for a typical small-sat mission is described for each of the two panel design technologies being studied. Benefits in respect to weight reduction, area reduction, and system cost reduction are analyzed and compared to conventional arrays.

  13. Panel fabrication utilizing GaAs solar cells

    Mardesich, N.

    1984-01-01

    The development of the GaAs solar cells for space applications is described. The activities in the fabrication of GaAs solar panels are outlined. Panels were fabricated while introducing improved quality control, soldering laydown and testing procedures. These panels include LIPS II, San Marco Satellite, and a low concentration panel for Rockwells' evaluation. The panels and their present status are discussed.

  14. Your Skin

    ... Safe Videos for Educators Search English Español Your Skin KidsHealth / For Kids / Your Skin What's in this ... body) are really dead skin cells. Bye-Bye Skin Cells These old cells are tough and strong, ...

  15. A tan in a test tube - in vitro models for investigating ultraviolet radiation-induced damage in skin.

    Fernandez, Tara L; Dawson, Rebecca A; Van Lonkhuyzen, Derek R; Kimlin, Michael G; Upton, Zee

    2012-06-01

    Presently, global rates of skin cancers induced by ultraviolet radiation (UVR) exposure are on the rise. In view of this, current knowledge gaps in the biology of photocarcinogenesis and skin cancer progression urgently need to be addressed. One factor that has limited skin cancer research has been the need for a reproducible and physiologically-relevant model able to represent the complexity of human skin. This review outlines the main currently-used in vitro models of UVR-induced skin damage. This includes the use of conventional two-dimensional cell culture techniques and the major animal models that have been employed in photobiology and photocarcinogenesis research. Additionally, the progression towards the use of cultured skin explants and tissue-engineered skin constructs, and their utility as models of native skin's responses to UVR are described. The inherent advantages and disadvantages of these in vitro systems are also discussed. © 2012 John Wiley & Sons A/S.

  16. Diagnosis of Latent Tuberculosis in Patients with Systemic Lupus Erythematosus: T.SPOT.TB versus Tuberculin Skin Test

    Maria Del Mar Arenas Miras

    2014-01-01

    Full Text Available Early studies in patients with systemic lupus erythematosus (SLE reported increased incidence of tuberculosis. The tuberculin skin test (TST is the technique of choice to detect latent tuberculosis infection (LTBI but has several limitations. Objectives. We compared TST and the newer T.SPOT.TB test to diagnose LTBI in SLE patients. Methods. In this observational cohort study conducted between August 2009 and February 2012, we recruited 92 patients from those attending the SLE clinic of our university hospital. Data recorded were epidemiological and sociodemographic characteristics. Laboratory analyses included TST and T.SPOT.TB tests. Results. Of the patients studied, 92% were women with an average age of 42.7 years. Overall, the degree of correlation between the two tests was low (Kappa index = 0.324 but was better in patients not receiving corticosteroids (CTC/immunosuppressive (IS therapy (Kappa = 0.436 and in those receiving hydroxychloroquine (Kappa = 0.473. While TST results were adversely affected by those receiving CTC and/or IS drugs (P=0.021, the T.SPOT.TB results were not. Conclusion. Although the TST test remains a useful tool for diagnosing LTBI in SLE patients, the T.SPOT.TB test is perhaps better employed when the patient is receiving CTC and/or IS drugs.

  17. Panel surveys

    MADRE, JL; ZUMKELLER, D; CHLOND, B; ARMOOGUM, J

    2004-01-01

    l'analyse du comportement humain constitue un enjeu important dans le domaine des transports, lequel se transforme radicalement sous la pression des évolutions économique, écologique et démographique. les premières grandes études ont commence il y a plus d'une dizaine d'années : parc auto sofres en france, puget sound panel a seattle. cet article fait le bilan de ces expériences et met en évidence les principaux problèmes méthodologiques rencontres tout en proposant de nouvelles directions d'...

  18. Prognostic value of asymptomatic skin sensitization to aeroallergens

    Bødtger, Uffe

    2004-01-01

    condition affecting 8-30% of the population when using a local standard panel of aeroallergens. Clinically, immediate but not late-phase reactions are induced by allergen challenge. Absent eosinophil stimulation and migration and low IL-5 levels appear to be sentinel mechanisms. Prospective studies show...... positive skin test must be ruled out before allergen avoidance measures are initiated. SUMMARY: Surprisingly few papers exist on asymptomatic skin sensitization epidemiology and immunology, despite the intriguing question as to why symptoms do not develop in IgE-sensitized patients. It is a common...

  19. Humoral immunity in tuberculin skin test anergy and its role in high-risk persons exposed to active tuberculosis.

    Encinales, Liliana; Zuñiga, Joaquin; Granados-Montiel, Julio; Yunis, Maria; Granados, Julio; Almeciga, Ingrid; Clavijo, Olga; Awad, Carlos; Collazos, Vilma; Vargas-Rojas, María Inés; Bañales-Mendez, José Luis; Vazquez-Castañeda, Lilia; Stern, Joel N; Romero, Viviana; Fridkis-Hareli, Masha; Frindkis-Hareli, Masha; Terreros, Daniel; Fernandez-Viña, Marcelo; Yunis, Edmond J

    2010-02-01

    The most common test to identify latent tuberculosis is the tuberculin skin test that detects T cell responses of delayed type hypersensitivity type IV. Since it produces false negative reactions in active tuberculosis or in high-risk persons exposed to tuberculosis patients as shown in this report, we studied antibody profiles to explain the anergy of such responses in high-risk individuals without active infection. Our results showed that humoral immunity against tuberculin, regardless of the result of the tuberculin skin test is important for protection from active tuberculosis and that the presence of high antibody titers is a more reliable indicator of infection latency suggesting that latency can be based on the levels of antibodies together with in vitro proliferation of peripheral blood mononuclear cells in the presence of the purified protein derivative. Importantly, anti-tuberculin IgG antibody levels mediate the anergy described herein, which could also prevent reactivation of disease in high-risk individuals with high antibody titers. Such anti-tuberculin IgG antibodies were also found associated with blocking and/or stimulation of in vitro cultures of PBMC with tuberculin. In this regard, future studies need to establish if immune responses to Mycobacterium tuberculosis can generate a broad spectrum of reactions either toward Th1 responses favoring stimulation by cytokines or by antibodies and those toward diminished responses by Th2 cytokines or blocking by antibodies; possibly involving mechanisms of antibody dependent protection from Mtb by different subclasses of IgG. Published by Elsevier Ltd.

  20. A SKIN TEST FOR DETECTING GROUP C HEMOLYTIC STREPTOCOCCAL INFECTION CAUSING EPIZOOTIC LYMPHADENITIS IN GUINEA PIGS : APPLICATIONS IN SELECTING BREEDING STOCK.

    Moen, J K

    1936-09-30

    1. A skin test with a crude bacterial extract prepared from group C (Lancefield) hemolytic streptococci was used as a means of detecting possible carriers of the streptococcus causing epizootic lymphadenitis in guinea pigs. A positive test similar to a positive tuberculin reaction was considered presumptive evidence of present or recent infection with this streptococcus. 2. 20 positive reactors were found in 330 supposedly normal guinea pigs. 3. 195 negatively reacting animals were used as a breeding stock which yielded 1,296 progeny over a period of 15 months. None of the breeding stock or their progeny showed evidence of spontaneous lymphadenitis. Skin tests of 100 of the progeny were all negative. 4. The use of this skin test as a means of obtaining guinea pig breeding stock free of the streptococcus causing spontaneous lymphadenitis is suggested.

  1. Testing the relationships between energy consumption, CO2 emissions, and economic growth in 24 African countries: a panel ARDL approach.

    Asongu, Simplice; El Montasser, Ghassen; Toumi, Hassen

    2016-04-01

    This study complements existing literature by examining the nexus between energy consumption (EC), CO2 emissions (CE), and economic growth (GDP; gross domestic product) in 24 African countries using a panel autoregressive distributed lag (ARDL) approach. The following findings are established. First, there is a long-run relationship between EC, CE, and GDP. Second, a long-term effect from CE to GDP and EC is apparent, with reciprocal paths. Third, the error correction mechanisms are consistently stable. However, in cases of disequilibrium, only EC can be significantly adjusted to its long-run relationship. Fourth, there is a long-run causality running from GDP and CE to EC. Fifth, we find causality running from either CE or both CE and EC to GDP, and inverse causal paths are observable. Causality from EC to GDP is not strong, which supports the conservative hypothesis. Sixth, the causal direction from EC to GDP remains unobservable in the short term. By contrast, the opposite path is observable. There are also no short-run causalities from GDP, or EC, or EC, and GDP to EC. Policy implications are discussed.

  2. Advanced Solar Panel Designs

    Ralph, E. L.; Linder, E. B.

    1995-01-01

    Solar panel designs that utilize new high-efficiency solar cells and lightweight rigid panel technologies are described. The resulting designs increase the specific power (W/kg) achievable in the near-term and are well suited to meet the demands of higher performance small satellites (smallsats). Advanced solar panel designs have been developed and demonstrated on two NASA SBIR contracts at Applied Solar. The first used 19% efficient, large area (5.5 cm x 6.5 cm) GaAs/Ge solar cells with a lightweight rigid graphite epoxy isogrid substrate configuration. A 1,445 sq cm coupon was fabricated and tested to demonstrate 60 W/kg with a high potential of achieving 80 W/kg. The second panel design used new 22% efficiency, dual-junction GaInP2/GaAs/Ge solar cells combined with a lightweight aluminum core/graphite fiber mesh facesheet substrate. A 1,445 sq cm coupon was fabricated and tested to demonstrate 105 W/kg with the potential of achieving 115 W/kg.

  3. First-in-man open clinical trial of a combined rdESAT-6 and rCFP-10 tuberculosis specific skin test reagent.

    Winnie Bergstedt

    2010-06-01

    Full Text Available Tuberculin is still the only available skin test reagent for the diagnosis of mycobacterial infection. The product has a remarkable sensitivity, but poor specificity. Previous studies, including two human phase I clinical trials, have indicated that rdESAT-6 has a potential as an improved skin test reagent. Animal studies have shown that the sensitivity may be increased by inclusion of the genetically related CFP-10 antigen in the preparation without loosing specificity.In this study a Lactococcus fermented, recombinant skin test reagent consisting of a 1ratio1 wt/wt of rdESAT-6 and CFP-10 was manufactured according to GMP standards and tested for the first time in 42 healthy adult volunteers. The two doses of 0.01 microg or 0.1 microg were injected intradermally by the Mantoux technique with 6 or 12 weeks interval. No serious adverse events and only mild adverse reactions were reported. The reagent elicited a positive skin test reaction after the first injection in one participant, who most likely was latently infected with M. tuberculosis as indicated by an appreciable IFN gamma response just below the Quantiferon(R cut-off level at the screening visit. None of the remaining participants in the four groups had any skin test reactions and sensitisation by the reagent could therefore be excluded.The investigational skin test reagent rdESAT-6 and CFP-10 appeared safe and non-sensitising in this first-in-man clinical trial in human volunteers and can now be tested in larger clinical trials involving individuals with latent M. tuberculosis infection or active TB disease.ClinicalTrials.gov NCT00793702.

  4. Liver Panel

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  5. Characterization of the mechanical properties of a dermal equivalent compared with human skin in vivo by indentation and static friction tests.

    Zahouani, H; Pailler-Mattei, C; Sohm, B; Vargiolu, R; Cenizo, V; Debret, R

    2009-02-01

    The study of changes in skin structure with age is becoming all the more important with the increase in life. The atrophy that occurs during aging is accompanied by more profound changes, with a loss of organization within the elastic collagen network and alterations in the basal elements. The aim of this study is to present a method to determine the mechanical properties of total human skin in vivo compared with dermal equivalents (DEs) using indentation and static friction tests. A new bio-tribometer working at a low contact pressure for the characterization the mechanical properties of the skin has been developed. This device, based on indentation and static friction tests, also allows to characterize the skin in vivo and reconstructed DEs in a wide range of light contact forces, stress and strain. This original bio-tribometer shows the ability to assess the skin elasticity and friction force in a wide range of light normal load (0.5-2 g) and low contact pressure (0.5-2 kPa). The results obtained by this approach show identical values of the Young's modulus E(*) and the shear modulus G(*) of six DEs obtained from a 62-year-old subject (E(*)=8.5+/-1.74 kPa and G(*)=3.3+/-0.46 kPa) and in vivo total skin of 20 subjects aged 55 to 70 years (E(*)=8.3+/-2.1 kPa, G(*)=2.8+/-0.8 kpa).

  6. Sensitization to cereals and peanut evidenced by skin prick test and specific IgE in food-tolerant, grass pollen allergic patients

    Martens, Maria; Schnoor, Heidi J; Malling, Hans-Jørgen

    2011-01-01

    The botanical relation between grass and cereal grains may be relevant when diagnosing food allergy to cereals. The aim was to investigate the diagnostic specificity of skin prick test (SPT) and specific immunoglobulin E (sIgE) tests to cereals and peanut in grass pollen allergic subjects without...

  7. Clinical evaluation of MPT-64 and MPT-59, two proteins secreted from Mycobacterium tuberculosis, for skin test reagents

    Wilcke, J T; Jensen, B N; Ravn, P

    1996-01-01

    : In a small scale clinical investigation, skin reactions to these antigens were compared to reactions to tuberculin PPD RT23 in 1) patients with active tuberculosis, 2) BCG vaccinated healthy subjects with close contact with tuberculous patients, and 3) BCG vaccinated healthy subjects without contact...... with tuberculous patients. Tests for in vitro reactivity to these antigens were carried out in similar groups. RESULTS: All subjects gave positive reaction to tuberculin PPD RT23, whereas approximately half of the subjects in each of the three groups reacted to MPT-59. Two subjects (one patient with tuberculosis...... and one healthy bacille Calmette-Guérin vaccinated subject without patient contact) reacted to MPT-64. The studies of cell proliferation and induction of interferon-gamma (IFN-gamma) following stimulation with tuberculin PPD and MPT-64 supported this profile of reactivity. CONCLUSION: None...

  8. Average Skin-Friction Drag Coefficients from Tank Tests of a Parabolic Body of Revolution (NACA RM-10)

    Mottard, Elmo J; Loposer, J Dan

    1954-01-01

    Average skin-friction drag coefficients were obtained from boundary-layer total-pressure measurements on a parabolic body of revolution (NACA rm-10, basic fineness ratio 15) in water at Reynolds numbers from 4.4 x 10(6) to 70 x 10(6). The tests were made in the Langley tank no. 1 with the body sting-mounted at a depth of two maximum body diameters. The arithmetic mean of three drag measurements taken around the body was in good agreement with flat-plate results, but, apparently because of the slight surface wave caused by the body, the distribution of the boundary layer around the body was not uniform over part of the Reynolds number range.

  9. Reliability of candida skin test in the evaluation of T-cell function in ...

    Ehab

    2017-01-23

    Jan 23, 2017 ... considered generally reliable under the age of 1 year.6 ... We sought to investigate the reliability of manually ... Conclusion: Candida intradermal test is a cost- effective ..... Ballow M. Historical perspectives in the diagnosis.

  10. Evaluation of ear skin temperature as a cow-side test to predict postpartum calcium status in dairy cows.

    Venjakob, P L; Borchardt, S; Thiele, G; Heuwieser, W

    2016-08-01

    Subclinical hypocalcemia is considered a gateway disease that increases susceptibility to other metabolic and infectious diseases in transition dairy cows. In the absence of a cow-side test, however, it is difficult to identify hypocalcemic cows. The objective of this study was to evaluate ear skin temperature as a diagnostic predictor of serum calcium concentration. We conducted a cross-sectional study on 7 commercial dairy farms, involving 251 cows 0 to 48h after calving. Skin temperature of the ears (STEar) was scored manually by palpating both ears. An infrared thermometer was used to measure ear temperature, skin temperature on the coxal tuber (STCox), and ambient temperature. Rectal temperature was measured using a digital thermometer. A blood sample was drawn to determine serum calcium concentration. Hypocalcemia was defined as serum calcium below 2.0mmol/L, irrespective of clinical symptoms. Serum calcium concentration cows in first, second, third, and fourth or greater lactation, respectively. None of the cows in first and second lactation had clinical milk fever. The prevalence of clinical milk fever was 6.0 and 20.3% for cows in their third and fourth or greater lactation, respectively. A decrease in ear temperature of 0.39°C [95% confidence interval (CI): 0.25-0.54] was associated with a decrease of 0.1mmol/L in serum calcium concentration. Ambient temperature, however, was a major confounder for ear temperature. With an increase in ambient temperature of 1°C, STEar rose by 0.78°C (95% CI: 0.67-0.90). Hypothermia was more pronounced in clinical milk fever (median 21.8°C; interquartile range 14.7-27.0°C) compared with subclinical hypocalcemia (median 27.6°C, interquartile range 22.1-30.8°C). All temperature estimates had only accurate test characteristics based on their area under the curve for prediction of subclinical hypocalcemia (area under the curve for STEar, STCox, and rectal temperature were 0.641, 0.668, and 0.606, respectively) when cows

  11. Determination of N-acetylglucosamine in cosmetic formulations and skin test samples by hydrophilic interaction liquid chromatography and UV detection.

    Pedrali, Alice; Bleve, Mariella; Capra, Priscilla; Jonsson, Tobias; Massolini, Gabriella; Perugini, Paola; Marrubini, Giorgio

    2015-03-25

    N-Acetylglucosamine is an ingredient in pharmaceuticals, nutritional supplements and in cosmetics. N-Acetylglucosamine in cosmetics is expected to improve skin hydration, reparation, and to contribute as anti-wrinkle agent. This study reports on the validation and application of an HPLC method based on HILIC and UV detection for determining N-acetylglucosamine in cosmetics and in samples obtained after testing the skin exposed to cosmetics formulations. The chromatographic column used is a ZIC(®)-pHILIC (150 mm × 4.6 mm, 5 μm particle size) on which a mobile phase containing acetonitrile-aqueous KH2PO4 (70:30, v/v) 15 mM was applied in isocratic elution mode injecting 20 μl of sample at 0.5 ml/min constant flow-rate and 10±1°C column temperature. Under these conditions the total run time was 10 min and N-acetylglucosamine eluted baseline separated from all other compounds in the samples. Calibration in the range from 40 to 80 μg/ml allowed to assess the method linearity (R(2)>0.999) in a concentration range corresponding to about 50% to 120% of the expected levels of N-acetylglucosamine in the formulations. Precision expressed by RSD% was always better than 2% in intra-day and inter-day assays of authentic samples. Accuracy was in all cases within 95-105% of the expected concentration value in formulations containing N-acetylglucosamine. The sensitivity of the method was at the level of 10 μg/ml as limit of detection, and at 40 μg/ml as limit of quantitation. The application of the method to formulations containing solid lipid nanoparticles documents its usefulness in cosmetic quality control. The results witness that the method is also suitable for the determination of N-acetylglucosamine in samples obtained from skin test strips. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Low and High Frequency Models of Response Statistics of a Cylindrical Orthogrid Vehicle Panel to Acoustic Excitation

    Smith, Andrew; LaVerde, Bruce; Teague, David; Gardner, Bryce; Cotoni, Vincent

    2010-01-01

    This presentation further develops the orthogrid vehicle panel work. Employed Hybrid Module capabilities to assess both low/mid frequency and high frequency models in the VA One simulation environment. The response estimates from three modeling approaches are compared to ground test measurements. Detailed Finite Element Model of the Test Article -Expect to capture both the global panel modes and the local pocket mode response, but at a considerable analysis expense (time & resources). A Composite Layered Construction equivalent global stiffness approximation using SEA -Expect to capture response of the global panel modes only. An SEA approximation using the Periodic Subsystem Formulation. A finite element model of a single periodic cell is used to derive the vibroacoustic properties of the entire periodic structure (modal density, radiation efficiency, etc. Expect to capture response at various locations on the panel (on the skin and on the ribs) with less analysis expense

  13. Assessment of the respiratory metabolism in the skin from transcutaneous measurements of pO2 and pCO2: potential for non-invasive monitoring of response to tuberculin skin testing.

    Abbot, N C; Spence, V A; Swanson-Beck, J; Carnochan, F M; Gibbs, J H; Lowe, J G

    1990-03-01

    A method is described for non-invasive transcutaneous (tc) measurement of tissue respiratory gas tensions in the skin on the forearm for study of delayed hypersensitivity reactions in man. Steady state values for tcpO2 and tcpCO2 were measured, and the skin respiratory rate (oxygen consumption) and the tissue pH were estimated from the changes in tcpO2 and tcpCO2 observed after interruption of the arterial circulation by cuff occlusion for 4 minutes. The extent of within-experiment and between subject variation in the steady-state measurements was not great (coefficient of variation 10%): tcpCO2.ss (steady state) was higher in men and tcpO2.ss was higher in women, but the extent of these sex differences was also small. Reference ranges have been established for tc measurements and calculated indices of tissue respiration in the undisturbed forearm skin of normal volunteers, against which the changes induced by tuberculin testing can be assessed. Severe changes, indicative of profound hypoxia and acidosis, are seen in intense delayed hypersensitivity reactions. Similar, but less severe changes were seen at the site of skin tests on BCG-vaccinated subjects who were 'negative' by conventional criteria of measurement of dermal induration and they became greatly exaggerated after successful re-vaccination. Intradermal injection of saline did not induce hypoxia or local acidosis. These new methods are very sensitive indicators of the tissue response in the DHS reaction.

  14. Determination of the axial and circumferential mechanical properties of the skin tissue using experimental testing and constitutive modeling.

    Karimi, Alireza; Navidbakhsh, Mahdi; Haghighatnama, Maedeh; Haghi, Afsaneh Motevalli

    2015-01-01

    The skin, being a multi-layered material, is responsible for protecting the human body from the mechanical, bacterial, and viral insults. The skin tissue may display different mechanical properties according to the anatomical locations of a body. However, these mechanical properties in different anatomical regions and at different loading directions (axial and circumferential) of the mice body to date have not been determined. In this study, the axial and circumferential loads were imposed on the mice skin samples. The elastic modulus and maximum stress of the skin tissues were measured before the failure occurred. The nonlinear mechanical behavior of the skin tissues was also computationally investigated through a suitable constitutive equation. Hyperelastic material model was calibrated using the experimental data. Regardless of the anatomic locations of the mice body, the results revealed significantly different mechanical properties in the axial and circumferential directions and, consequently, the mice skin tissue behaves like a pure anisotropic material. The highest elastic modulus was observed in the back skin under the circumferential direction (6.67 MPa), while the lowest one was seen in the abdomen skin under circumferential loading (0.80 MPa). The Ogden material model was narrowly captured the nonlinear mechanical response of the skin at different loading directions. The results help to understand the isotropic/anisotropic mechanical behavior of the skin tissue at different anatomical locations. They also have implications for a diversity of disciplines, i.e., dermatology, cosmetics industry, clinical decision making, and clinical intervention.

  15. In Vitro Antimicrobial Susceptibility Testing of Animal Nocardia Isolated from Field Cases of Skin Diseases

    M. A. Oyekunle

    2001-03-01

    Full Text Available In vitro antimicrobial tests were carried out on strains of Nocardia isolated from field cases of cutaneous nocardiosis in farm animals. Results with the disc diffusion test showed the multiresistant nature of the isolates, but 23.81 and 21.43% were sensitive to ciprofloxacin and gentamycin, respectively. The MIC mode and range for oxytetracycline were 12.5 and 3.12–25 μg/ml, respectively, while those of erythromycin were 3.12 and 0.78–6.25 μg/ml, respectively.

  16. Catch-up validation study of an in vitro skin irritation test method based on an open source reconstructed epidermis (phase II).

    Groeber, F; Schober, L; Schmid, F F; Traube, A; Kolbus-Hernandez, S; Daton, K; Hoffmann, S; Petersohn, D; Schäfer-Korting, M; Walles, H; Mewes, K R

    2016-10-01

    To replace the Draize skin irritation assay (OECD guideline 404) several test methods based on reconstructed human epidermis (RHE) have been developed and were adopted in the OECD test guideline 439. However, all validated test methods in the guideline are linked to RHE provided by only three companies. Thus, the availability of these test models is dependent on the commercial interest of the producer. To overcome this limitation and thus to increase the accessibility of in vitro skin irritation testing, an open source reconstructed epidermis (OS-REp) was introduced. To demonstrate the capacity of the OS-REp in regulatory risk assessment, a catch-up validation study was performed. The participating laboratories used in-house generated OS-REp to assess the set of 20 reference substances according to the performance standards amending the OECD test guideline 439. Testing was performed under blinded conditions. The within-laboratory reproducibility of 87% and the inter-laboratory reproducibility of 85% prove a high reliability of irritancy testing using the OS-REp protocol. In addition, the prediction capacity was with an accuracy of 80% comparable to previous published RHE based test protocols. Taken together the results indicate that the OS-REp test method can be used as a standalone alternative skin irritation test replacing the OECD test guideline 404. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. PV panel model based on datasheet values

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2007-01-01

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....... Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested....

  18. Long-term repeatability of the skin prick test is high when supported by history or allergen-sensitivity tests

    Bødtger, Uffe; Jacobsen, C R; Poulsen, L K

    2003-01-01

    subjects. An SPT was positive when > or =3 mm, and repeatable if either persistently positive or negative. Clinical sensitivity to birch pollen was used as model for inhalation allergy, and was investigated at inclusion and at study termination by challenge tests, intradermal test, titrated SPT and Ig......E measurements. Birch pollen symptoms were confirmed in diaries. RESULTS: The repeatability of a positive SPT was 67%, increasing significantly to 100% when supported by the history. When not supported by history, the presence of specific IgE was significantly associated with a repeatable SPT. Allergen....... CONCLUSION: SPT changes are clinically relevant. Further studies using other allergens are needed. Long-term repeatability of SPT is high in the presence of a supportive history....

  19. Compressive Behavior of Frame-Stiffened Composite Panels

    Yovanof, Nicolette P.; Jegley, Dawn C.

    2011-01-01

    New technologies are being developed under NASA's Environmentally Responsible Aviation (ERA) Program aimed at reducing fuel burn and emissions in large commercial aircraft. A Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept is being developed which offers advantages over traditional metallic structure. In this concept a stitched carbon-epoxy material system is employed with the potential for reducing the weight and cost of transport aircraft structure by eliminating fasteners and producing a more damage tolerant design. In addition, by adding unidirectional carbon rods to the top of stiffeners and minimizing the interference between the sandwich frames and the rod-stiffened stringers, the panel becomes more structurally efficient. This document describes the results of experimentation on a PRSEUS panel in which the frames are loaded in unidirectional compression beyond the local buckling of the skin of a Hybrid Wing Body (HWB) aircraft. A comparison with analytical predictions and the relationship between these test results and the global aircraft design is presented.

  20. Smear grading and the Mantoux skin test can be used to predict sputum smear conversion in patients suffering from tuberculosis

    Saffari, Mahmood

    2017-08-01

    Full Text Available Purpose: Smear scores and induration sizes resulting from the PPD (tuberculin purified protein derivative test can serve as indicators of whether a patient suffering from tuberculosis shows smear conversion or not. Methods: Using microbiological methods smear and sputum tests, patients diagnosed as infected with between 2002 and 2015 were included in this study. All of the assumed factors that may have a role in smear conversion were studied, in addition to the prolongation of tuberculosis. Results: 398 of 512 patients fulfilled all the inclusion criteria and formed the basis of this study. 215 patients (54% were females and 183 (46% were males. The median age for both men and women was 36 years. We found a statistically significant difference between the size of induration resulting from the PPD skin test and the rate of non-conversion (=0.002. Further univariate analysis also showed that smear grading and an induration size of ≥10 mm were independently associated with delayed smear conversion. Patients with cavitary lesions showed a higher rate of non-conversion after two months, which was not significant. We could not find any association between some of the variables, such as age, sex, weight, smoking, alcoholism, addictions, respiratory diseases, diabetes mellitus, alternative anti-TB treatment, and smear conversion. Conclusion: Intensified treatment and precautions against transmission should be especially considered for TB patients with high smear grading and an induration size of more than 10 mm.

  1. Screening Test for Shed Skin Cells by Measuring the Ratio of Human DNA to Staphylococcus epidermidis DNA.

    Nakanishi, Hiroaki; Ohmori, Takeshi; Hara, Masaaki; Takahashi, Shirushi; Kurosu, Akira; Takada, Aya; Saito, Kazuyuki

    2016-05-01

    A novel screening method for shed skin cells by detecting Staphylococcus epidermidis (S. epidermidis), which is a resident bacterium on skin, was developed. Staphylococcus epidermidis was detected using real-time PCR. Staphylococcus epidermidis was detected in all 20 human skin surface samples. Although not present in blood and urine samples, S. epidermidis was detected in 6 of 20 saliva samples, and 5 of 18 semen samples. The ratio of human DNA to S. epidermidisDNA was significantly smaller in human skin surface samples than in saliva and semen samples in which S. epidermidis was detected. Therefore, although skin cells could not be identified by detecting only S. epidermidis, they could be distinguished by measuring the S. epidermidis to human DNA ratio. This method could be applied to casework touch samples, which suggests that it is useful for screening whether skin cells and human DNA are present on potential evidentiary touch samples. © 2016 American Academy of Forensic Sciences.

  2. Dermal safety assessment of Arm & Hammer laundry products formulated for sensitive skin.

    Frederick, Douglas M; Vorwerk, Linda; Gupta, Archana; Ghassemi, Annahita

    2017-09-01

    product (Arm & Hammer Free & Clear) and other nonirritant controls. In the Wrist Band Wear test, exposure to laundered fabrics under exaggerated conditions gave similar results for the test and control products, with no objective signs of skin irritation, and no self-reported persistent adverse sensory effects. Very mild, transient and isolated sensory effects were noted in daily diaries by a small proportion of subjects, and were similar for the test and control products. The Safety In-Use tests evaluated 4-week exposure to product and laundered fabrics under realistic use conditions. There were no clinically objective signs of skin irritation, and reports of transitory, mild sensory effects were minimal and similar for the test and controls. A comprehensive skin safety program on a lightly scented sensitive skin laundry formulation (i.e. Arm & Hammer™ Sensitive Skin plus Skin-Friendly Fresh Scent) conducted among panels of self-assessed sensitive skin subjects demonstrated that the presence of a light fragrance did not adversely impact skin compatibility in any of the testing protocols when the product was compared to a similar product with no fragrance. The lightly fragranced product demonstrated overall skin compatibility and mildness when tested in a self-assessed sensitive skin population, and compared favorably to currently marketed sensitive skin products.

  3. Opt-Out Panel Testing for HIV, Hepatitis B and Hepatitis C in an Urban Emergency Department: A Pilot Study.

    Sarah O'Connell

    Full Text Available Studies suggest 2 per 1000 people in Dublin are living with HIV, the level above which universal screening is advised. We aimed to assess the feasibility and acceptability of a universal opt-out HIV, Hepatitis B and Hepatitis C testing programme for Emergency Department patients and to describe the incidence and prevalence of blood-borne viruses in this population.An opt-out ED blood borne virus screening programme was piloted from March 2014 to January 2015. Patients undergoing blood sampling during routine clinical care were offered HIV 1&2 antibody/antigen assay, HBV surface antigen and HCV antibody tests. Linkage to care where necessary was co-ordinated by the study team. New diagnosis and prevalence rates were defined as the new cases per 1000 tested and number of positive tests per 1000 tested respectively.Over 45 weeks of testing, of 10,000 patient visits, 8,839 individual patient samples were available for analysis following removal of duplicates. A sustained target uptake of >50% was obtained after week 3. 97(1.09%, 44(0.49% and 447(5.05% HIV, Hepatitis B and Hepatitis C tests were positive respectively. Of these, 7(0.08%, 20(0.22% and 58(0.66% were new diagnoses of HIV, Hepatitis B and Hepatitis C respectively. The new diagnosis rate for HIV, Hepatitis B and Hepatitis C was 0.8, 2.26 and 6.5 per 1000 and study prevalence for HIV, Hepatitis B and Hepatitis C was 11.0, 5.0 and 50.5 per 1000 respectively.Opt-out blood borne viral screening was feasible and acceptable in an inner-city ED. Blood borne viral infections were prevalent in this population and newly diagnosed cases were diagnosed and linked to care. These results suggest widespread blood borne viral testing in differing clinical locations with differing population demographic risks may be warranted.

  4. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M.

    1991-01-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician

  5. Characterization of small-to-medium head-and-face dimensions for developing respirator fit test panels and evaluating fit of filtering facepiece respirators with different faceseal design

    Lin, Yi-Chun

    2017-01-01

    A respirator fit test panel (RFTP) with facial size distribution representative of intended users is essential to the evaluation of respirator fit for new models of respirators. In this study an anthropometric survey was conducted among youths representing respirator users in mid-Taiwan to characterize head-and-face dimensions key to RFTPs for application to small-to-medium facial features. The participants were fit-tested for three N95 masks of different facepiece design and the results compared to facial size distribution specified in the RFTPs of bivariate and principal component analysis design developed in this study to realize the influence of facial characteristics to respirator fit in relation to facepiece design. Nineteen dimensions were measured for 206 participants. In fit testing the qualitative fit test (QLFT) procedures prescribed by the U.S. Occupational Safety and Health Administration were adopted. As the results show, the bizygomatic breadth of the male and female participants were 90.1 and 90.8% of their counterparts reported for the U.S. youths (P < 0.001), respectively. Compared to the bivariate distribution, the PCA design better accommodated variation in facial contours among different respirator user groups or populations, with the RFTPs reported in this study and from literature consistently covering over 92% of the participants. Overall, the facial fit of filtering facepieces increased with increasing facial dimensions. The total percentages of the tests wherein the final maneuver being completed was “Moving head up-and-down”, “Talking” or “Bending over” in bivariate and PCA RFTPs were 13.3–61.9% and 22.9–52.8%, respectively. The respirators with a three-panel flat fold structured in the facepiece provided greater fit, particularly when the users moved heads. When the facial size distribution in a bivariate RFTP did not sufficiently represent petite facial size, the fit testing was inclined to overestimate the general fit

  6. Skin tests of pollen grains of taxodiaceae and cupressaceae in children with bronchial asthma.

    Midoro-Horiuti, T; Nouno, S; Seino, Y

    1992-10-01

    Atmospheric cedar pollen in the southern region of Okayama Prefecture (situated in south-western Japan) has been counted since 1988. Pollen of different species of the Taxodiaceae family (Cryptomeria japonica, Sequoia sempervirens and Metasequoia glyptostroboides) and Japanese juniper (Juniperus rigida) in the Cupressaceae family, which are propagated mainly in the southern region of Okayama Prefecture, were found among the atmospheric pollen. Scratch tests using the pollen extract from Taxodiaceae and Cupressaceae were performed on children with bronchial asthma. Forty (25%) and 30 (18.8%) of the 160 patients reacted positively to an allergen extract from the pollen grains of Japanese cedar (Cryptomeria japonica) and Japanese juniper, respectively.

  7. The mini-dome Fresnel lens photovoltaic concentrator array - Current status of component and prototype panel testing

    Piszczor, M. F.; Swartz, C. K.; O'Neill, M. J.; Mcdanal, A. J.; Fraas, L. M.

    1990-01-01

    NASA Lewis and ENTECH have been developing a high-efficiency, lightweight space photovoltaic concentrator array. The emphasis of the program has shifted to fabrication and testing of the minidome Fresnel lens and other array components. Protototype lenses have been tested for optical efficiency, with results around 90 percent, and tracking error performance. The results of these tests have been very consistent with the predicted analytical performance. Work has also progressed in the fabrication of the array support structure. Recent advances in 30 percent efficient stacked cell technology will have a significant effect on the array performance. It is concluded that near-term array performance goals of 300 W/sq m and 100 W/kg are feasible.

  8. 1994 Panel 1 Utilization Plan

    1994-01-01

    The Waste Isolation Pilot Plant (WIPP) is intended to receive, handle, and permanently dispose of transuranic (TRU) waste. To fulfill this mission, the U.S. Department of Energy (DOE) constructed a full-scale facility to demonstrate both technical and operational principles of the permanent isolation of TRU waste. The WIPP consists of surface and underground facilities. Panel 1 is situated in the underground facility horizon which is located approximately 2,150 feet below the surface in the predominantly halite Salado Formation. The Panel 1 Utilization Plan provides a strategy for the optimum use of Panel 1 which is consistent with the priorities established by the DOE to accomplish the WIPP mission. These priorities, which include maintaining personnel safety, conducting performance assessment, and continued operational enhancements, are the guiding premise for the decisions on the planned usage of the WIPP underground facility. The continuation of ongoing investigations along with the planned testing and training to be carried out in Panel 1 will enhance the current knowledge and understanding of the operational and geotechnical aspects of the panel configuration. This enhancement will ultimately lead to safer, more efficient, and more cost-effective methods of operation. Excavation of the waste storage area began in May 1986 with the mining of entries to Panel 1. The original design for the waste storage rooms at the WIPP provided a limited period of time during which to mine the openings and to emplace waste. Each panel, consisting of seven storage rooms, was scheduled to be mined and filled in less than 5 years. Panel 1 was developed to receive waste for a demonstration phase that was scheduled to start in October 1988. The demonstration phase was deferred, and the experimental test program was modified to use contact-handled (CH) transuranic waste in bin-scale tests, planned for Room 1, Panel 1

  9. Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the design and use of a thin metallic calorimeter for measuring heat transfer rate (also called heat flux). Thermocouples are attached to the unexposed surface of the calorimeter. A one-dimensional heat flow analysis is used for calculating the heat transfer rate from the temperature measurements. Applications include aerodynamic heating, laser and radiation power measurements, and fire safety testing. 1.2 Advantages 1.2.1 Simplicity of ConstructionThe calorimeter may be constructed from a number of materials. The size and shape can often be made to match the actual application. Thermocouples may be attached to the metal by spot, electron beam, or laser welding. 1.2.2 Heat transfer rate distributions may be obtained if metals with low thermal conductivity, such as some stainless steels, are used. 1.2.3 The calorimeters can be fabricated with smooth surfaces, without insulators or plugs and the attendant temperature discontinuities, to provide more realistic flow conditions for ...

  10. Nuclear electronic equipment for control and monitoring panel. Procedure guide for on-site tests of nuclear reactor instruments

    1975-10-01

    By the use of a procedure for on-site testing of nuclear reactor instruments it should be possible to judge their ability to guarantee the reactor safety and availability at the moment of divergence or during operation. Such a procedure must therefore be created as a work implement for the quick and reliable installation of electronic devices necessary for nuclear reactor control and supervision. A standard document is proposed for this purpose, allowing a ''test programme'' to be set up before the equipment is installed on the site [fr

  11. Panel Discussion

    Langer, James

    1997-03-01

    Panelists: Arthur Bienenstock, Stanford University Cherry Ann Murray, Lucent Technologies Venkatesh Narayanamurti, University of California-Santa Barbara Paul Peercy, SEMI-SEMATECH Robert Richardson, Cornell University James Roberto, Oak Ridge National Laboratory The Board on Physics and Astronomy is undertaking a series of reassessments of all branches of physics as the foundation of a new physics survey. As part of this project, a Committee on Condensed Matter and Materials Physics has been established under the leadership of Venkatesh Narayanamurti of the University of California-Santa Barbara. The committee has been working since June on a study that will include an illustrative recounting of major recent achievements; identification of new opportunities and challenges facing the field; and articulation-for leaders in government, industry, universities, and the public at large-of the important roles played by the field in modern society. An especially urgent issue is how to maintain the intellectual vitality of condensed matter and materials physics, and its contributions to the well-being of the United States, in an era of limited resources. The forum will feature a panel of materials researchers who are members of the Committee on Condensed Matter and Materials Physics. They will give a brief report on the status of the study and engage in a dialogue with the audience about issues facing the condensed matter and materials physics community. Broad community input is vital to the success of the study. Please come and make your voice heard!

  12. Skin Conditions

    Your skin is your body's largest organ. It covers and protects your body. Your skin Holds body fluids in, preventing dehydration Keeps harmful ... it Anything that irritates, clogs, or inflames your skin can cause symptoms such as redness, swelling, burning, ...

  13. Opt-Out Panel Testing for HIV, Hepatitis B and Hepatitis C in an Urban Emergency Department: A Pilot Study.

    O'Connell, Sarah

    2016-01-01

    Studies suggest 2 per 1000 people in Dublin are living with HIV, the level above which universal screening is advised. We aimed to assess the feasibility and acceptability of a universal opt-out HIV, Hepatitis B and Hepatitis C testing programme for Emergency Department patients and to describe the incidence and prevalence of blood-borne viruses in this population.

  14. Evaluation of the frequency of food allergens based on skin prick test in children in Kurdistan Province - Iran.

    Kalmarzi, R; Ataee, P; Homagostar, Gh; Tagik, M; Ghaderi, E; Kooti, W

    Food allergy refers to abnormal reactions of the body caused by an immune system response to food. This study was conducted aiming to investigate allergy to food allergens in children with food allergies. This study was conducted as a cross-sectional one on 304 children aged six months to seven years with food allergies admitted to the tertiary referral hospital in Kurdistan Province - Iran, during 2014-2015. All the patients were examined for skin prick test using 49 allergens. Finally, the obtained data were analysed using SPSS15 and chi-square and t tests. The highest percentage of occurrence of bump reaction (wheal) and redness (flare) was due to the consumption of fish, eggs, tomatoes, and cocoa. Moreover, the lowest rate of wheal and flare was caused by exposure to allergens like latex, tea, malt, and wheat flour. The reaction most created due to the consumption of foods was flare which was higher among under three-year-olds group (p<0.05), and between the sexes, girls showed the most common allergic reactions (p<0.05). Since food allergy has a high prevalence in children, it should be considered with great interest. Considering that avoiding food allergens is the first step in the treatment of food allergies, the present study may be a useful guide in this regard. Copyright © 2017 SEICAP. Published by Elsevier España, S.L.U. All rights reserved.

  15. The value of counting BCG scars for interpretation of tuberculin skin tests in a tuberculosis hyperendemic shanty-town, Peru

    Saito, M.; Bautista, C. T.; Gilman, R. H.; Bowering, A.; Levy, M. Z.; Evans, C. A.

    2010-01-01

    SUMMARY SETTING The tuberculin skin test (TST) is widely used as a diagnostic or screening test for Mycobacterium tuberculosis infection and disease. A peri-urban shanty-town in the desert hills of south Lima, Peru, highly endemic for tuberculosis, and where bacille Calmette-Guérin (BCG) vaccine had been given in multiple doses until 1995. OBJECTIVE To analyze the effect of multiple BCG vaccines on TST in a community-based setting. DESIGN Point-prevalence survey of TST reactions of 572 people aged 6–26 years from 255 households. TST reactions were compared to the observed number of BCG scars and other potential risk factors (age, living with a TST-positive person, and contact with active tuberculosis). RESULT People with two or more scars had significantly larger reactions, even after adjusting for potential risk factors. The adjusted population attributable fraction of being TST-positive and having two or more BCG scars was 26%. CONCLUSION There is no demonstrated benefit of repeat BCG vaccination. We therefore recommend that physicians take into consideration the number of BCG scars when interpreting the TST and that programs give no more than one BCG vaccination. PMID:15260275

  16. Autologous serum skin test as an indicator of chronic autoimmune urticaria in a tertiary care hospital in South India.

    Vikramkumar, Adaikalampillai Ganapathy; Kuruvila, Sheela; Ganguly, Satyaki

    2014-12-01

    Autologous serum skin test (ASST) is a simple in-vivo clinical test for the detection of basophil histamine releasing activity and to diagnose chronic autoimmune urticaria (CAU) among chronic spontaneous urticaria (CSU) patients. Diagnosing these patients is also important as they may need high doses of antihistamines and systemic corticosteroids during acute exacerbations. The aim of this study is to study the prevalence of CAU among cases of CSU by using ASST. This was a cross-sectional study done among 48 patients presenting with CSU. Detailed history, physical examination and routine investigations were recorded for all patients. ASST was done on all the 48 patients. Of the 48 patients included in the study, 20 patients (41.6%) were ASST positive, while the remaining 28 (58%) were ASST negative. The median duration of disease in both ASST positive and negative patients was 1 year. ASST positivity was higher (66.6%) among patients with a history of round shaped weals, though not statistically significant. ASST positivity was seen in 5 (71.4%) out of seven patients with systemic involvement, which was again not statistically significant. Our study did not show any significant difference between patients with and without antibodies regarding mean age and sex distribution, clinical morphology of individual weals, duration, severity, systemic symptoms, angioedema, atopy, and association with other autoimmune conditions.

  17. Randomized Clinical Trial of the Innovative Bilayered Wound Dressing Made of Silk and Gelatin: Safety and Efficacy Tests Using a Split-Thickness Skin Graft Model

    Hasatsri, Sukhontha; Angspatt, Apichai

    2015-01-01

    We developed the novel silk fibroin-based bilayered wound dressing for the treatment of partial thickness wounds. And it showed relevant characteristics and accelerated the healing of full-thickness wounds in a rat model. This study is the clinical evaluation of the bilayered wound dressing to confirm its safety and efficacy for the treatment of split-thickness skin donor sites. The safety test was performed using a patch model and no evidence of marked and severe cutaneous reactions was found. The efficacy test of the bilayered wound dressing was conducted on 23 patients with 30 split-thickness skin graft donor sites to evaluate healing time, pain score, skin barrier function, and systemic reaction in comparison to Bactigras. We found that the healing time of donor site wounds treated with the bilayered wound dressing (11 ± 6 days) was significantly faster than those treated with Bactigras (14 ± 6 days) (p = 10−6). The wound sites treated with the bilayered wound dressing showed significantly less pain and more rapid skin functional barrier recovery than those treated with Bactigras (p = 10−5). Therefore, these results confirmed the clinical safety and efficacy of the bilayered wound dressing for the treatment of split-thickness skin graft donor sites. PMID:26221170

  18. A genomic biomarker signature can predict skin sensitizers using a cell-based in vitro alternative to animal tests

    Albrekt Ann-Sofie

    2011-08-01

    Full Text Available Abstract Background Allergic contact dermatitis is an inflammatory skin disease that affects a significant proportion of the population. This disease is caused by an adverse immune response towards chemical haptens, and leads to a substantial economic burden for society. Current test of sensitizing chemicals rely on animal experimentation. New legislations on the registration and use of chemicals within pharmaceutical and cosmetic industries have stimulated significant research efforts to develop alternative, human cell-based assays for the prediction of sensitization. The aim is to replace animal experiments with in vitro tests displaying a higher predictive power. Results We have developed a novel cell-based assay for the prediction of sensitizing chemicals. By analyzing the transcriptome of the human cell line MUTZ-3 after 24 h stimulation, using 20 different sensitizing chemicals, 20 non-sensitizing chemicals and vehicle controls, we have identified a biomarker signature of 200 genes with potent discriminatory ability. Using a Support Vector Machine for supervised classification, the prediction performance of the assay revealed an area under the ROC curve of 0.98. In addition, categorizing the chemicals according to the LLNA assay, this gene signature could also predict sensitizing potency. The identified markers are involved in biological pathways with immunological relevant functions, which can shed light on the process of human sensitization. Conclusions A gene signature predicting sensitization, using a human cell line in vitro, has been identified. This simple and robust cell-based assay has the potential to completely replace or drastically reduce the utilization of test systems based on experimental animals. Being based on human biology, the assay is proposed to be more accurate for predicting sensitization in humans, than the traditional animal-based tests.

  19. A genomic biomarker signature can predict skin sensitizers using a cell-based in vitro alternative to animal tests

    2011-01-01

    Background Allergic contact dermatitis is an inflammatory skin disease that affects a significant proportion of the population. This disease is caused by an adverse immune response towards chemical haptens, and leads to a substantial economic burden for society. Current test of sensitizing chemicals rely on animal experimentation. New legislations on the registration and use of chemicals within pharmaceutical and cosmetic industries have stimulated significant research efforts to develop alternative, human cell-based assays for the prediction of sensitization. The aim is to replace animal experiments with in vitro tests displaying a higher predictive power. Results We have developed a novel cell-based assay for the prediction of sensitizing chemicals. By analyzing the transcriptome of the human cell line MUTZ-3 after 24 h stimulation, using 20 different sensitizing chemicals, 20 non-sensitizing chemicals and vehicle controls, we have identified a biomarker signature of 200 genes with potent discriminatory ability. Using a Support Vector Machine for supervised classification, the prediction performance of the assay revealed an area under the ROC curve of 0.98. In addition, categorizing the chemicals according to the LLNA assay, this gene signature could also predict sensitizing potency. The identified markers are involved in biological pathways with immunological relevant functions, which can shed light on the process of human sensitization. Conclusions A gene signature predicting sensitization, using a human cell line in vitro, has been identified. This simple and robust cell-based assay has the potential to completely replace or drastically reduce the utilization of test systems based on experimental animals. Being based on human biology, the assay is proposed to be more accurate for predicting sensitization in humans, than the traditional animal-based tests. PMID:21824406

  20. 5-HTTLPR Expression Outside the Skin: An Experimental Test of the Emotional Reactivity Hypothesis in Children.

    Weeland, Joyce; Slagt, Meike; Brummelman, Eddie; Matthys, Walter; de Castro, Bram Orobio; Overbeek, Geertjan

    2015-01-01

    There is increasing evidence that variation in the promoter region of the serotonin transporter gene SLC6A4 (i.e., the 5-HTTLPR polymorphism) moderates the impact of environmental stressors on child psychopathology. Emotional reactivity -the intensity of an individual's response to other's emotions- has been put forward as a possible mechanism underlying these gene-by-environment interactions (i.e., G×E). Compared to children homozygous for the L-allele (LL-genotypes), children carrying an S-allele (SS/SL-genotypes), specifically when they have been frequently exposed to negative emotions in the family environment, might be more emotionally reactive and therefore more susceptible to affective environmental stressors. However, the association between 5-HTTLPR and emotional reactivity in children has not yet been empirically tested. Therefore, the goal of this study was to test this association in a large-scale experiment. Children (N = 521, 52.5% boys, Mage = 9.72 years) were genotyped and randomly assigned to happy, angry or neutral dynamic facial expressions and vocalizations. Motor and affective emotional reactivity were assessed through children's self-reported negative and positive affect (n = 460) and facial electromyography activity (i.e., fEMG: the zygomaticus or "smile" muscle and the corrugator or "frown" muscle, n = 403). Parents reported on their negative and positive parenting behaviors. Children mimicked and experienced the emotion they were exposed to. However, neither motor reactivity nor affective reactivity to these emotions depended on children's 5-HTTLPR genotype: SS/SL-genotypes did not manifest any stronger response to emotional stimuli than LL-genotypes. This finding remained the same when taking the broader family environment into account, controlling for kinship, age, gender and genetic ancestry, and when including a tri-allelic factor. We found no evidence for an association between the 5-HTTLPR polymorphism and children's emotional

  1. The Shock and Vibration Bulletin. Part 1. Opening Session, Panel Session, Shock Analysis Shock Testing, Isolation and Damping.

    1977-09-01

    ORTHOTROPIC PLATES WITH VARIOUS ,I PLANFORMS AND EDGE CONDITIONS C.W. Bert, The University of Oklahoma, Norman , OK - -’ DYNAMIC RESPONSE OF LAMINATED...EVALUATION OF AN ADAPTIVE FILTER AS A DIGITAL TRACKING FILTER D.O. Smallwood and D.L. Gregory, Sandia Laboratories, Albuquerque, NM TOTAL MISSION ENVIRONMENTAL...June 1967. ration Bulletin No. 40, Part 2, 1969. 6. J. P. Barthmaier, "Shock Testing Under 2. D. 0. Smallwood , "Time History Synthesis Minicomputer

  2. Quantitative studies on impact resistance of reinforced concrete panels with steel liners under impact loading. Part 1: Scaled model impact tests

    Tsubota, H.; Kasai, Y.; Koshika, N.; Morikawa, H.; Uchida, T.; Ohno, T.; Kogure, K.

    1993-01-01

    In recent years, extensive analytical and experimental studies have been carried out to establish a rational structural design method for nuclear power plants against local damage caused by various external missiles. Through these studies, several techniques for improving die impact resistance of reinforced concrete slabs have been proposed. Of these techniques, attaching a thin steel liner onto the impacted and/or rear face of the slab is considered to be one of the most effective methods. Muto et. al. carried out full-scale impact tests using actual aircraft engines and reported that a thin corrugated steel liner attached to the rear face of a concrete panel has a significant effect in preventing scattering of scabbed concrete debris from the rear face of the target. Based on many experimental and analytical studies, UKAEA reported that a steel liner attached to a reinforced concrete slab improves its perforation and scabbing resistance, and Walter et. al. proposed a formula for predicting the equivalent thickness of a slab with a steel liner attached. The object of this study was to evaluate quantitatively the effect of a steel liner attached to a reinforced concrete slab in preventing local damage caused by rigid missiles. To achieve the object, extensive impact tests were carried out. This paper summarizes the results of these tests

  3. Skin abscess

    Abscess - skin; Cutaneous abscess; Subcutaneous abscess; MRSA - abscess; Staph infection - abscess ... Skin abscesses are common and affect people of all ages. They occur when an infection causes pus ...

  4. Filling the concept with data: integrating data from different in vitro and in silico assays on skin sensitizers to explore the battery approach for animal-free skin sensitization testing.

    Natsch, Andreas; Emter, Roger; Ellis, Graham

    2009-01-01

    Tests for skin sensitization are required prior to the market launch of new cosmetic ingredients. Significant efforts are made to replace the current animal tests. It is widely recognized that this cannot be accomplished with a single in vitro test, but that rather the integration of results from different in vitro and in silico assays will be needed for the prediction of the skin sensitization potential of chemicals. This has been proposed as a theoretical scheme so far, but no attempts have been made to use experimental data to prove the validity of this concept. Here we thus try for the first time to fill this widely cited concept with data. To this aim, we integrate and report both novel and literature data on 116 chemicals of known skin sensitization potential on the following parameters: (1) peptide reactivity as a surrogate for protein binding, (2) induction of antioxidant/electrophile responsive element dependent luciferase activity as a cell-based assay; (3) Tissue Metabolism Simulator skin sensitization model in silico prediction; and (4) calculated octanol-water partition coefficient. The results of the in vitro assays were scaled into five classes from 0 to 4 to give an in vitro score and compared to the local lymph node assay (LLNA) data, which were also scaled from 0 to 4 (nonsensitizer/weak/moderate/strong/extreme). Different ways of evaluating these data have been assessed to rate the hazard of chemicals (Cooper statistics) and to also scale their potency. With the optimized model an overall accuracy for predicting sensitizers of 87.9% was obtained. There is a linear correlation between the LLNA score and the in vitro score. However, the correlation needs further improvement as there is still a relatively high variation in the in vitro score between chemicals belonging to the same sensitization potency class.

  5. Specificity of the Tuberculin Skin Test and the T-SPOT."TB" Assay among Students in a Low-Tuberculosis Incidence Setting

    Talbot, Elizabeth A.; Harland, Dawn; Wieland-Alter, Wendy; Burrer, Sherry; Adams, Lisa V.

    2012-01-01

    Objective: Interferon-[gamma] release assays (IGRAs) are an important tool for detecting latent "Mycobacterium tuberculosis" infection (LTBI). Insufficient data exist about IGRA specificity in college health centers, most of which screen students for LTBI using the tuberculin skin test (TST). Participants: Students at a low-TB incidence college…

  6. Flight Test Techniques. Proceedings of the Flight Mechanics Panel Symposium Held in Lisbon, Portugal on 2-5 April 1984

    1984-07-01

    E103 3000 200 270090 1800 Fig. 7: Antenna Radiation Pattern Aircraft: D028. Type of Antenna: Monopole Frequency: 1.5 6Nz, Bank Angle: 0±Z Deg. Ref...Pattern: - - - Monopole Mr 70 250 F 4g. 8: S.uae1tpcl S0OA0r a) Test Emitter: Frequency Range UHF -18 GHz Antenna Parabolic Dish Wln Horn Feeds Transmitter...essais d’extinction et rallumages moteur, de flottement, etc.. Un effort sp~cial a 6t consacr6, Ai Istres, A Ia mice en place de moyens et dispositifs

  7. Extent and effects of recurrent shortages of purified-protein derivative tuberculin skin test antigen solutions - United States, 2013.

    2013-12-13

    Two purified-protein derivative (PPD) tuberculin skin test (TST) antigen solutions are approved by the U.S. Food and Drug Administration (FDA): Tubersol (Sanofi Pasteur Limited) and Aplisol (JHP Pharmaceuticals, LLC). Tubersol was out of production in late 2012 through April 2013. Shortages of Aplisol have resulted from increased demand as practitioners have sought a substitute for Tubersol. Tubersol production resumed in May 2013, and supplies had been nearly restored by early June. However, in mid-July, state tuberculosis (TB) control officials notified CDC of difficulty obtaining Tubersol and Aplisol. Sanofi Pasteur notified FDA of a temporary delay in the availability of tuberculin in the 10-dose and 50-dose presentations. In mid-October, the 10-dose presentation was being returned to market, on allocation, which means that historical purchasing practices determine the amount that customers are allotted. In late October, the 50-dose presentation was being returned to market, also on allocation, one vial per historical customer per month. Supplies are forecast to approach normal during January 2014, after distributors have restored their supply chains. A compensatory surge in testing after deferment of testing during the periods of shortage might cause further temporary instability of supplies. In mid-August 2013, officials in 29 of 52 U.S. jurisdictions noted a shortage of at least one PPD TST antigen solution in health departments to the extent that it interrupted activities. This report includes a summary of the extent and effects of the shortages and a reiteration of advice on how to adapt to them.

  8. Reduction of residual stresses in internal skin of transient zones of PWR steam generator expanded tubes: tests with a ''rotating brush''

    Vidal, P.

    1984-04-01

    A process aiming at preventing or suppressing cracks under stress corrosion on the primary side in the expanded zones of PWR steam generator tubes has been studied; it consists in hammering the internal skin of tubes in these zones what reduces the level of residual expanding stresses to lower values around 100-150 MPa without modifying the stress level in external skin. Tests in magnesium chloride to estimate the residual stresses of tubes in low carbon stainless austenitic steel 18% Cr-12% Ni with molybdene [fr

  9. Testing and evaluation of a slot and tab construction technique for light-weight wood-fiber-based structural panels under bending

    Jinghao Li; John F. Hunt; Shaoqin Gong; Zhiyong Cai

    2015-01-01

    This paper presented construction and strain distributions for light-weight wood-fiber-based structural panels with tri-grid core made from phenolic impregnated laminated paper composites under bending. A new fastening configuration of slots in the faces and tabs on the core was applied to the face/core interfaces of the sandwich panel in addition to epoxy resin. Both...

  10. Study on reactor building structure using ultrahigh strength materials - Part 6: Tests for joints of SC-frames and PCa-panels

    Uchiyama, T.; Ishimura, K.; Takahashi, T.; Kei, T.

    1993-01-01

    A mixed structure composed of reinforced concrete precast panels and frames of steel beams and concrete filled steel tube columns using ultrahigh strength materials was proposed for reactor buildings. The paper describes the structural characteristics of the high tension bolt joints between the panels and the frames. (author)

  11. Direct current linear measurement sub-assembly data and test methods. Nuclear electronic equipment for control and monitoring panel

    1977-12-01

    The M.C.H./M.E.N.T.3 document is concerned with sub-assemblies intended for measuring on a linear scale the neutron fluence rate or radiation dose rate when connected with nuclear detectors working in current. The symbols used are described. Some definitions and a bibliography are given. The main characteristics of direct current linear measurement sub-assemblies are then described together with corresponding test methods. This type of instrument indicates on a linear scale the level of a direct current applied to its input. The document reviews linear sub-assemblies for general purpose applications, difference amplifiers for monitoring, and averaging amplifiers. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials and plant operators [fr

  12. Point-of-care Beta-lactam Allergy Skin Testing by Antimicrobial Stewardship Programs: A Pragmatic Multicenter Prospective Evaluation.

    Leis, Jerome A; Palmay, Lesley; Ho, Grace; Raybardhan, Sumit; Gill, Suzanne; Kan, Tiffany; Campbell, Jackie; Kiss, Alex; McCready, Janine B; Das, Pavani; Minnema, Brian; Powis, Jeff E; Walker, Sandra A N; Ferguson, Heather; Wong, Benny; Weber, Elizabeth

    2017-06-01

    Beta-lactam allergy skin testing (BLAST) is recommended by antimicrobial stewardship program (ASP) guidelines, yet few studies have systematically evaluated its impact when delivered at point-of-care. We conducted a pragmatic multicenter prospective evaluation of the use of point-of-care BLAST by ASPs. In staggered 3-month intervals, ASP teams at three hospitals received training by allergists to offer BLAST for eligible patients with infectious diseases receiving non-preferred beta-lactam therapy due to severity of their allergy. The primary outcome was the proportion of patients receiving the preferred beta-lactam therapy. Of 827 patients with reported beta-lactam allergy over 15-months, beta-lactam therapy was preferred among 632(76%). During baseline periods, 50% (124/246) received preferred beta-lactam therapy based on history, compared with 60% (232/386) during the intervention periods (p=0.02), which improved further to 81% (313/386) upon provision of BLAST (pcare across three hospital ASPs resulted in greater use of preferred beta-lactam therapy without increasing the risk of adverse drug reactions. Longer term studies are needed to better assess the safety and clinical impact of this ASP intervention. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  13. Tuberculin Skin Test and Quantiferon in BCG Vaccinated, Immunosuppressed Patients with Moderate-to-Severe Inflammatory Bowel Disease.

    Kurti, Zsuzsanna; Lovasz, Barbara Dorottya; Gecse, Krisztina Barbara; Balint, Anita; Farkas, Klaudia; Morocza-Szabo, Agnes; Gyurcsanyi, Andras; Kristof, Katalin; Vegh, Zsuzsanna; Gonczi, Lorant; Kiss, Lajos Sandor; Golovics, Petra Anna; Lakatos, Laszlo; Molnar, Tamas; Lakatos, Peter Laszlo

    2015-12-01

    There are few data available on the effect of immunomodulator/biological therapy on the accuracy of the tuberculin skin test (TST) and interferon-gamma release assay (IGRA) in BCG-vaccinated immunosuppressed patients with inflammatory bowel disease (IBD). Our aim was to define the accuracy, predictors and agreement of TST and IGRA in a BCG-vaccinated immunosuppressed referral IBD cohort. 166 consecutive moderate-to-severe IBD patients (122 Crohn's disease, CD and 44 ulcerative colitis, UC) were enrolled in a prospective study from three centers. Patients were treated with immunosuppressives and/or biologicals. IGRA and TST were performed on the same day. Both in- and outpatient records were collected and comprehensively reviewed. TST positivity rate was 23.5%, 21.1%,14.5% and 13.9% when cut-off values of 5, 10, 15 and 20mm were used. IGRA positivity rate was 8.4% with indeterminate result in 0.6%. Chest X-ray was suggestive of latent tuberculosis in 2 patients. Correlation between TST and IGRA was moderate (kappa: 0.39-0.41, p15mm) should be considered to identify patients at risk for latent TB. Accuracy is satisfactory in BCG-vaccinated, immunosuppressed IBD patients. Smoking is a risk factor for TST positivity.

  14. Characterization and diagnostic evaluation of chronic polyneuropathies induced by oxaliplatin and docetaxel comparing skin biopsy to quantitative sensory testing and nerve conduction studies

    Krøigård, T; Schrøder, H D; Qvortrup, C

    2014-01-01

    was to characterize the neuropathies with regard to symptoms, neurological signs and objective evidence of damage to the structure and function of the peripheral nerves. Furthermore, the diagnostic values of skin biopsy, quantitative sensory testing (QST) and nerve conduction studies (NCS) were compared. METHODS......: Patients complaining of neuropathy symptoms at least 3 months after completion of treatment with oxaliplatin (n = 20) or docetaxel (n = 20) were recruited from the Department of Oncology or using hospital records. Neuropathy scores were determined along with the intraepidermal nerve fibre density in skin....... Mechanical detection threshold was most often affected in the QST. NCS, QTS and skin biopsy were abnormal in 11, 13 and 17 and 7, 11 and 15 of the oxaliplatin-treated patients and docetaxel-treated patients, respectively. CONCLUSIONS: Chemotherapy-induced peripheral neuropathy after oxaliplatin or docetaxel...

  15. Serial testing of refugees for latent tuberculosis using the QuantiFERON-gold in-tube: effects of an antecedent tuberculin skin test.

    Baker, Cristina A; Thomas, William; Stauffer, William M; Peterson, Phillip K; Tsukayama, Dean T

    2009-04-01

    Screening for latent tuberculosis infection (LTBI) in refugee populations immigrating to low-incidence countries remains a challenge. We assessed the characteristics of the QuantiFERON-Gold In-Tube (QFT-GIT) compared with the tuberculin skin test (TST) in 198 refugees of all ages from tuberculosis-endemic countries. Diagnostic agreement between the first QFT-GIT and simultaneous TST was 78% (kappa = 0.56) and between serial QFT-GITs was 89% (kappa = 0.76). In serial QFT-GIT testing, 70% of subjects had an increased QFT-GIT value, perhaps the result of an antecedent TST in the setting of previous TB exposure. This boosting seemed to become less prevalent with time from TST and occurred less frequently in those with negative first QFT-GIT readings. Despite small changes in the quantitative results caused by nonspecific variation and boosting, the diagnostic result of the QFT-GIT was reliable. The QFT-GIT shows the potential to replace the TST for LTBI screening in refugees from tuberculosis-endemic areas.

  16. QuantiFERON-TB Gold In-Tube as a Confirmatory Test for Tuberculin Skin Test in Tuberculosis Contact Tracing: A Noninferiority Clinical Trial.

    Muñoz, Laura; Santin, Miguel; Alcaide, Fernando; Ruíz-Serrano, Maria Jesús; Gijón, Paloma; Bermúdez, Elena; Domínguez-Castellano, Angel; Navarro, María Dolores; Ramírez, Encarnación; Pérez-Escolano, Elvira; López-Prieto, María Dolores; Gutiérrez-Rodriguez, José; Anibarro, Luis; Calviño, Laura; Trigo, Matilde; Cifuentes, Carmen; García-Gasalla, Mercedes; Payeras, Antoni; Gasch, Oriol; Espasa, Mateu; Agüero, Ramon; Ferrer, Diego; Casas, Xavier; González-Cuevas, Araceli; García-Zamalloa, Alberto; Bikuña, Edurne; Lecuona, María; Galindo, Rosa; Ramírez-Lapausa, Marta; Carrillo, Raquel

    2018-01-18

    Screening strategies based on interferon-γ release assays in tuberculosis contact tracing may reduce the need for preventive therapy without increasing subsequent active disease. We conducted an open-label, randomized trial to test the noninferiority of a 2-step strategy with the tuberculin skin test (TST) followed by QuantiFERON-TB Gold In-Tube (QFT-GIT) as a confirmatory test (the TST/QFT arm) to the standard TST-alone strategy (TST arm) for targeting preventive therapy in household contacts of patients with tuberculosis. Participants were followed for 24 months after randomization. The primary endpoint was the development of tuberculosis, with a noninferiority margin of 1.5 percentage points. A total of 871 contacts were randomized. Four contacts in the TST arm and 2 in the TST/QFT arm developed tuberculosis. In the modified intention-to-treat analysis, this accounted for 0.99% in the TST arm and 0.51% in the TST/QFT arm (-0.48% difference; 97.5% confidence interval [CI], -1.86% to 0.90%); in the per-protocol analysis, the corresponding rates were 1.67% and 0.82% in the TST and TST/QFT arms, respectively (-0.85% difference; 97.5% CI, -3.14% to 1.43%). Of the 792 contacts analyzed, 65.3% in the TST arm and 42.2% in the TST/QFT arm were diagnosed with tuberculosis infection (23.1% difference; 95% CI, 16.4% to 30.0%). In low-incidence settings, screening household contacts with the TST and using QFT-GIT as a confirmatory test is not inferior to TST-alone for preventing active tuberculosis, allowing a safe reduction of preventive treatments. NCT01223534. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  17. Skin Cancer.

    Linares, Miguel A; Zakaria, Alan; Nizran, Parminder

    2015-12-01

    Skin cancer accounts for most malignancies across the globe. They are primarily divided into melanoma and nonmelanoma skin malignancies. Nonmelanoma skin cancer includes basal cell carcinoma and squamous cell carcinoma. Fair skin and chronic ultraviolet B exposure are the most important risk factors. Primary prevention is achieved by avoiding sun exposure and tanning beds. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Microbiological and chemico-physical shelf-life and panel test to evaluate acceptability of liver mortadella

    Erica Tirloni

    2016-11-01

    Full Text Available This study aimed to evaluate the shelf life of sliced cooked liver mortadella packaged in MAP (70-85% N2, 15-30% CO2 and stored in refrigeration (4°C or slight thermal abuse (8°C for up to 49 days (declared best before date 45 days. The proximate composition, aw nitrites and NaCl content were determined at T0. Weekly, samples were submitted to microbiological [total viable count (TVC, lactic acid bacteria (LAB, Enterobacteriaceae, Escherichia coli, Pseudomonas spp., coagulase positive staphylococci, sulphite reducing clostridia, yeasts and moulds, Listeria monocytogenes and Salmonella spp.] and physicalchemical analyses [pH, colorimetric parameters, total volatile basic nitrogen (TVBN, thiobarbituric acid reactive substances (TBARs], in parallel with consumer acceptability tests. The product characteristics (low salt and nitrites concentration, high aw and pH close to 6.5 were not efficient hurdles for microbial growth. No pathogens were detected in the samples; the initial TVC [5.4 Log colony forming unit (CFU/g] increased rapidly, reaching values around 8 Log CFU/g at T14 for both the series, and was almost totally composed by LAB, leading to the acidification of the product (pH at T49=5.05 at 4°C and 5.24 at 8°C. The other microbiological parameters were below 2 Log CFU/g. The product showed a good protein and lipid stability (TVBN <33 N/100 g and TBARs <8 nmol/g at T49. The sensorial quality of liver mortadella was more affected by the storage time than by the temperature. An evident colour modification was detected after T35, when the product was also frequently rejected by the panellists, mainly due to odour. Thus, the shelf life of sliced cooked liver mortadella should be shortened below 30 days.

  19. An in vitro method for detecting chemical sensitization using human reconstructed skin models and its applicability to cosmetic, pharmaceutical, and medical device safety testing.

    McKim, James M; Keller, Donald J; Gorski, Joel R

    2012-12-01

    Chemical sensitization is a serious condition caused by small reactive molecules and is characterized by a delayed type hypersensitivity known as allergic contact dermatitis (ACD). Contact with these molecules via dermal exposure represent a significant concern for chemical manufacturers. Recent legislation in the EU has created the need to develop non-animal alternative methods for many routine safety studies including sensitization. Although most of the alternative research has focused on pure chemicals that possess reasonable solubility properties, it is important for any successful in vitro method to have the ability to test compounds with low aqueous solubility. This is especially true for the medical device industry where device extracts must be prepared in both polar and non-polar vehicles in order to evaluate chemical sensitization. The aim of this research was to demonstrate the functionality and applicability of the human reconstituted skin models (MatTek Epiderm(®) and SkinEthic RHE) as a test system for the evaluation of chemical sensitization and its potential use for medical device testing. In addition, the development of the human 3D skin model should allow the in vitro sensitization assay to be used for finished product testing in the personal care, cosmetics, and pharmaceutical industries. This approach combines solubility, chemical reactivity, cytotoxicity, and activation of the Nrf2/ARE expression pathway to identify and categorize chemical sensitizers. Known chemical sensitizers representing extreme/strong-, moderate-, weak-, and non-sensitizing potency categories were first evaluated in the skin models at six exposure concentrations ranging from 0.1 to 2500 µM for 24 h. The expression of eight Nrf2/ARE, one AhR/XRE and two Nrf1/MRE controlled gene were measured by qRT-PCR. The fold-induction at each exposure concentration was combined with reactivity and cytotoxicity data to determine the sensitization potential. The results demonstrated that

  20. Evaluation of the NanoCHIP® Gastrointestinal Panel (GIP Test for Simultaneous Detection of Parasitic and Bacterial Enteric Pathogens in Fecal Specimens.

    Shifra Ken Dror

    Full Text Available Infectious gastroenteritis is a global health problem associated with high morbidity and mortality rates. Rapid and accurate diagnosis is crucial to allow appropriate and timely treatment. Current laboratory stool testing has a long turnaround time (TAT and demands highly qualified personnel and multiple techniques. The need for high throughput and the number of possible enteric pathogens compels the implementation of a molecular approach which uses multiplex technology, without compromising performance requirements. In this work we evaluated the feasibility of the NanoCHIP® Gastrointestinal Panel (GIP (Savyon Diagnostics, Ashdod, IL, a molecular microarray-based screening test, to be used in the routine workflow of our laboratory, a big outpatient microbiology laboratory. The NanoCHIP® GIP test provides simultaneous detection of nine major enteric bacteria and parasites: Campylobacter spp., Salmonella spp., Shigella spp., Giardia sp., Cryptosporidium spp., Entamoeba histolytica, Entamoeba dispar, Dientamoeba fragilis, and Blastocystis spp. The required high-throughput was obtained by the NanoCHIP® detection system together with the MagNA Pure 96 DNA purification system (Roche Diagnostics Ltd., Switzerland. This combined system has demonstrated a higher sensitivity and detection yield compared to the conventional methods in both, retrospective and prospective samples. The identification of multiple parasites and bacteria in a single test also enabled increased efficiency of detecting mixed infections, as well as reduced hands-on time and work load. In conclusion, the combination of these two automated systems is a proper response to the laboratory needs in terms of improving laboratory workflow, turn-around-time, minimizing human errors and can be efficiently integrated in the routine work of the laboratory.