WorldWideScience

Sample records for size precede whole-body

  1. Altered skeletal muscle fiber composition and size precede whole-body insulin resistance in young men with low birth weight

    DEFF Research Database (Denmark)

    Jensen, Christine B; Storgaard, Heidi; Madsbad, Sten

    2007-01-01

    CONTEXT: Low birth weight (LBW), a surrogate marker of an adverse fetal milieu, is linked to muscle insulin resistance, impaired insulin-stimulated glycolysis, and future risk of type 2 diabetes. Skeletal muscle mass, fiber composition, and capillary density are important determinants of muscle f...... was not significantly different between groups. CONCLUSION: Alterations in fiber composition and size may contribute to development of type 2 diabetes in individuals with LBW....

  2. Dependence of a whole body counting efficiency on body size and composition

    International Nuclear Information System (INIS)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R.

    2001-01-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  3. Dependence of a whole body counting efficiency on body size and composition

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Luzia; Campos, Vicente P.; Berti, Eduardo A.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2001-07-01

    An approach is described to evaluate the counting efficiency dependence, on the geometry measurement and on the material density, for whole body measurement. The counting efficiency is evaluated using Monte Carlo Method to simulate the history of the photons, from its emission to its total absorption or escape from the detector. Theoretical calculations of the counting efficiency are presented for two phantoms of the BOMAB family. The phantoms are considered to be filled with water and with a material constituted as described by Snyder et al. (author)

  4. The Effect of Submaximal Exercise Preceded by Single Whole-Body Cryotherapy on the Markers of Oxidative Stress and Inflammation in Blood of Volleyball Players

    Directory of Open Access Journals (Sweden)

    Celestyna Mila-Kierzenkowska

    2013-01-01

    Full Text Available The aim of the study was to determine the effect of single whole-body cryotherapy (WBC session applied prior to submaximal exercise on the activity of antioxidant enzymes, the concentration of lipid peroxidation products, total oxidative status, and the level of cytokines in blood of volleyball players. The study group consisted of 18 male professional volleyball players, who were subjected to extremely cold air (−130∘C prior to exercise performed on cycloergometer. Blood samples were taken five times: before WBC, after WBC procedure, after exercise preceded by cryotherapy (WBC exercise, and before and after exercise without WBC (control exercise. The activity of catalase statistically significantly increased after control exercise. Moreover, the activity of catalase and superoxide dismutase was lower after WBC exercise than after control exercise (P<0.001. After WBC exercise, the level of IL-6 and IL-1β was also lower (P<0.001 than after control exercise. The obtained results may suggest that cryotherapy prior to exercise may have some antioxidant and anti-inflammatory properties. The relations between the level of studied oxidative stress and inflammatory markers may testify to the contribution of reactive oxygen species in cytokines release into the blood system in response to exercise and WBC.

  5. The Effect of Submaximal Exercise Preceded by Single Whole-Body Cryotherapy on the Markers of Oxidative Stress and Inflammation in Blood of Volleyball Players

    Science.gov (United States)

    Mila-Kierzenkowska, Celestyna; Szpinda, Michał; Augustyńska, Beata; Woźniak, Bartosz

    2013-01-01

    The aim of the study was to determine the effect of single whole-body cryotherapy (WBC) session applied prior to submaximal exercise on the activity of antioxidant enzymes, the concentration of lipid peroxidation products, total oxidative status, and the level of cytokines in blood of volleyball players. The study group consisted of 18 male professional volleyball players, who were subjected to extremely cold air (−130°C) prior to exercise performed on cycloergometer. Blood samples were taken five times: before WBC, after WBC procedure, after exercise preceded by cryotherapy (WBC exercise), and before and after exercise without WBC (control exercise). The activity of catalase statistically significantly increased after control exercise. Moreover, the activity of catalase and superoxide dismutase was lower after WBC exercise than after control exercise (P cryotherapy prior to exercise may have some antioxidant and anti-inflammatory properties. The relations between the level of studied oxidative stress and inflammatory markers may testify to the contribution of reactive oxygen species in cytokines release into the blood system in response to exercise and WBC. PMID:24489985

  6. Whole body counter calibration using Monte Carlo modeling with an array of phantom sizes based on national anthropometric reference data

    Science.gov (United States)

    Shypailo, R. J.; Ellis, K. J.

    2011-05-01

    During construction of the whole body counter (WBC) at the Children's Nutrition Research Center (CNRC), efficiency calibration was needed to translate acquired counts of 40K to actual grams of potassium for measurement of total body potassium (TBK) in a diverse subject population. The MCNP Monte Carlo n-particle simulation program was used to describe the WBC (54 detectors plus shielding), test individual detector counting response, and create a series of virtual anthropomorphic phantoms based on national reference anthropometric data. Each phantom included an outer layer of adipose tissue and an inner core of lean tissue. Phantoms were designed for both genders representing ages 3.5 to 18.5 years with body sizes from the 5th to the 95th percentile based on body weight. In addition, a spherical surface source surrounding the WBC was modeled in order to measure the effects of subject mass on room background interference. Individual detector measurements showed good agreement with the MCNP model. The background source model came close to agreement with empirical measurements, but showed a trend deviating from unity with increasing subject size. Results from the MCNP simulation of the CNRC WBC agreed well with empirical measurements using BOMAB phantoms. Individual detector efficiency corrections were used to improve the accuracy of the model. Nonlinear multiple regression efficiency calibration equations were derived for each gender. Room background correction is critical in improving the accuracy of the WBC calibration.

  7. Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes.

    Science.gov (United States)

    Bhati, S; Patni, H K; Ghare, V P; Singh, I S; Nadar, M Y

    2012-03-01

    Internal contamination due to high-energy photon (HEP) emitters is assessed using a scanning bed whole-body monitor housed in a steel room at the Bhabha Atomic Research Centre (BARC). The monitor consists of a (203 mm diameter × 102 mm thickness) NaI(Tl) detector and is calibrated using a Reference BOMAB phantom representative of an average Indian radiation worker. However, a series of different size physical phantoms are required to account for size variability in workers, which is both expensive and time consuming. Therefore, a theoretical approach based on Monte Carlo techniques has been employed to calibrate the system in scanning geometry with BOMAB phantoms of different sizes characterised by their weight (W) and height (H) for several radionuclides of interest ((131)I, (137)Cs, (60)Co and (40)K). A computer program developed for this purpose generates the detector response and the detection efficiencies (DEs) for the BARC Reference phantom (63 kg/168 cm), ICRP Reference male phantom (70 kg/170 cm) and several of its scaled versions. The results obtained for different size phantoms indicated a decreasing trend of DEs with the increase in W/H values of the phantoms. The computed DEs for uniform distribution of (137)Cs in BOMAB phantom varied from 3.52 × 10(-3) to 2.88 × 10(-3) counts per photon as the W/H values increased from 0.26 to 0.50. The theoretical results obtained for the BARC Reference phantom have been verified with experimental measurements. The Monte Carlo results from this study will be useful for in vivo assessment of HEP emitters in radiation workers of different physiques.

  8. Comparative analysis of imaging sensitivity of positron emission mammography and whole-body PET in relation to tumor size.

    Science.gov (United States)

    Yamamoto, Yayoi; Ozawa, Yukihiko; Kubouchi, Kouichi; Nakamura, Seigo; Nakajima, Yasuo; Inoue, Tomio

    2015-01-01

    Positron emission mammography (PEM) consists of a dedicated PET scanner for breast imaging with a higher spatial resolution than whole-body PET (WBPET) scanners. This study compared the imaging sensitivity of PEM with WBPET in relation to tumor size. Fifty-four Japanese women younger than 50 years with histologically confirmed breast lesions were retrospectively enrolled. Positron emission mammography and WBPET were conducted on the same day. Positron emission mammography and WBPET images were blindly evaluated and compared with histopathology. Tumors were classified into 3 groups based on size as follows: group 1, 1 cm or smaller; group 2, 1 to 2 cm; and group 3, larger than 2 cm. The sensitivities of PEM and WBPET were compared in overall subjects and in each size group. In visual analysis, the overall imaging sensitivity was 78.6% (33/42) for PEM and 47.6% (20/42) for WBPET. The overall sensitivity of PEM was significantly higher than that of WBPET (P PEM and WBPET were larger in smaller tumors: group 1 (66.7% vs 13.3%), group 2 (63.4% vs 36.4%), and group 3 (100.0% vs 87.5%). The sensitivity of PEM was significantly higher than that of WBPET in group 1 (P = 0.008); however, no significant differences were seen in group 2 (P = 0.500) or group 3 (P = 0.250). Overall, the imaging specificity of PEM and WEBPET was 90.6% (60/66) and 93.9% (62/66), respectively. The imaging sensitivity of PEM was higher than that of WBPET in Japanese women younger than 50 years. Positron emission mammography showed significant sensitivity in tumors smaller than 1 cm, which has been a weak point for WBPET.

  9. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  10. Associations between adiposity, hormones, and gains in height, whole-body height-adjusted bone size, and size-adjusted bone mineral content in 8- to 11-year-old children

    DEFF Research Database (Denmark)

    Dalskov, Stine-Mathilde; Ritz, Christian; Larnkjær, Anni

    2016-01-01

    We examined fat-independent associations of hormones with height and whole-body bone size and mineral content in 633 school children. IGF-1 and osteocalcin predict growth in height, while fat, osteocalcin, and in girls also, IGF-1 predict growth in bone size. Leptin and ghrelin are inversely......, adiponectin, leptin, insulin, insulin-like growth factor-I (IGF-1), osteocalcin, and intact parathyroid hormone, and subsequent changes in height and in whole-body height-adjusted bone area "BAheight" and size-adjusted bone mineral content "BMCsize" in 8- to 11-year-olds. METHODS: Analyses were carried out...... associated with bone size in girls. INTRODUCTION: Obesity causes larger bone size and bone mass, but the role of hormones in this up-regulation of bone in obesity is not well elucidated. We examined longitudinal associations between baseline body fat mass (FM), and fat-independent fasting levels of ghrelin...

  11. The ORNL whole body counter

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs. (TEM)

  12. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  13. The ORNL whole body counter

    International Nuclear Information System (INIS)

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs

  14. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  15. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  16. Associations between adiposity, hormones, and gains in height, whole-body height-adjusted bone size, and size-adjusted bone mineral content in 8- to 11-year-old children.

    Science.gov (United States)

    Dalskov, S; Ritz, C; Larnkjær, A; Damsgaard, C T; Petersen, R A; Sørensen, L B; Ong, K K; Astrup, A; Michaelsen, K F; Mølgaard, C

    2016-04-01

    We examined fat-independent associations of hormones with height and whole-body bone size and mineral content in 633 school children. IGF-1 and osteocalcin predict growth in height, while fat, osteocalcin, and in girls also, IGF-1 predict growth in bone size. Leptin and ghrelin are inversely associated with bone size in girls. Obesity causes larger bone size and bone mass, but the role of hormones in this up-regulation of bone in obesity is not well elucidated. We examined longitudinal associations between baseline body fat mass (FM), and fat-independent fasting levels of ghrelin, adiponectin, leptin, insulin, insulin-like growth factor-I (IGF-1), osteocalcin, and intact parathyroid hormone, and subsequent changes in height and in whole-body height-adjusted bone area "BAheight" and size-adjusted bone mineral content "BMCsize" in 8- to 11-year-olds. Analyses were carried out separately for boys (n = 325) and girls (n = 308) including data from baseline, 3 and 6 months from OPUS School Meal Study. In both sexes: gain in BAheight was positively associated with baseline FM (≥2.05 cm(2)/kg, both p ≤ 0.003). Furthermore, gain in height was positively associated with baseline IGF-1 (≥0.02 cm/ng/ml, p = 0.001) and osteocalcin (≥0.13 cm/ng/ml, p ≤ 0.009); and gain in BAheight was positively associated with baseline osteocalcin (≥0.35 cm(2)/ng/ml, p ≤ 0.019). In girls only, gain in BAheight was also positively associated with baseline IGF-1 (0.06 cm(2)/ng/ml, p = 0.017) and inversely associated with both baseline ghrelin (-0.01 cm(2)/pg/ml, p = 0.001) and leptin (-1.21 cm(2)/μg/ml, p = 0.005). In boys, gain in BMCsize was positively associated with osteocalcin (0.18 g/ng/ml, p = 0.030). This large longitudinal study suggests that in 8- to 11-year-old children, IGF-1 and osteocalcin predict growth in height, while FM, osteocalcin, and in girls also, IGF-1 predict growth in BAheight. Fat-independent inverse

  17. Whole body autoradiography, ch. 13

    International Nuclear Information System (INIS)

    Jonkman, J.H.G.

    1977-01-01

    The distribution of 35 S-ringlabelled thiazinamium methylsulphate has been studied by means of whole body autoradiography in a squirrel and in mice. Accumulation of activity was found in liver, kidney and intestines (the excretion of pathways). High concentrations were also found in organs with high amount of acetylcholine receptors and in the glandular tissue. No radioactivity was seen in the central nervous system, indicating no passage through the 'blood-brain barrier'. This is the most significant difference with its tertiary analogue Prometharine hydrochloride. In pregnant mice, high concentrations were found in the placenta but only low amounts were found in liver and kidneys of the foetuses

  18. The evolution of whole-body imaging.

    LENUS (Irish Health Repository)

    Moran, Deirdre E

    2012-02-01

    This article reviews the evolution of whole-body imaging, discussing the history and development of radiography, nuclear medicine, computed tomography (CT), positron emission tomography (PET), combined PET-CT, and magnetic resonance imaging. The obstacles hindering progress toward whole-body imaging using each of these modalities, and the technical advances that were developed to overcome them, are reviewed. The effectiveness and the limitations of whole-body imaging with each of these techniques are also briefly discussed.

  19. Whole body vibration improves cognition in healthy young adults.

    Directory of Open Access Journals (Sweden)

    G Ruben H Regterschot

    Full Text Available This study investigated the acute effects of passive whole body vibration (WBV on executive functions in healthy young adults. Participants (112 females, 21 males; age: 20.5±2.2 years underwent six passive WBV sessions (frequency 30 Hz, amplitude approximately 0.5 mm and six non-vibration control sessions of two minutes each while sitting on a chair mounted on a vibrating platform. A passive WBV session was alternated with a control session. Directly after each session, performance on the Stroop Color-Block Test (CBT, Stroop Color-Word Interference Test (CWIT, Stroop Difference Score (SDS and Digit Span Backward task (DSBT was measured. In half of the passive WBV and control sessions the test order was CBT-CWIT-DSBT, and DSBT-CBT-CWIT in the other half. Passive WBV improved CWIT (p = 0.009; effect size r = 0.20 and SDS (p = 0.034; r = 0.16 performance, but only when the CBT and CWIT preceded the DSBT. CBT and DSBT performance did not change. This study shows that two minutes passive WBV has positive acute effects on attention and inhibition in young adults, notwithstanding their high cognitive functioning which could have hampered improvement. This finding indicates the potential of passive WBV as a cognition-enhancing therapy worth further evaluation, especially in persons unable to perform active forms of exercise.

  20. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  1. Incorporation monitoring with whole-body counters

    International Nuclear Information System (INIS)

    Steger, F.; Lovranich, E.; Urbanich, E.

    1988-01-01

    Whole-body counters are an important tool in dose measurements after incorporation. The present state in the design of whole-body measurements installations is shown and foreseeable developments are presented. Results of measurements and commited dose equivalent determinations are discussed with Chernobyl as an example. 9 refs., 10 figs., 3 tabs. (Authors, translated qui)

  2. International intercomparison of whole body counters

    International Nuclear Information System (INIS)

    Andrasi, A.; Beleznay, E.

    1980-01-01

    An international intercomparison of whole-body counters with the participation of 7 laboratories from 5 member countries was organized in 1976 by the Consultative Scientific and Technical Council for Radiation Protection of the CMEA. The Health Physics Department of the Central Research Institute for Physics also participated in this intercomparison. The main aim of the participation was to check our calibration method, measuring and evaluation procedures to determine their suitability for routine measurements and to investigate the advantages and drawbacks of applying different measuring geometries and evaluation methods. The final results of the intercomparison including our data in more detail are shown in the paper. The results obtained for different measuring geometries, evaluation methods and phantom sizes applying a simple calibration procedure are also given. The results show that a simplified calibration method using point sources embedded in an elliptic cylinder shaped scattering medium and a computerized least square fitting procedure in the evaluation of measurements combine to yield a final accuracy of +-15% in the gamma energy range of 250-1500 keV assuming uniformly distributed sources, a wide range of body sizes, and the choice of a particular measuring geometry. (author)

  3. Whole-body counters in Canada

    International Nuclear Information System (INIS)

    Letourneau, C.

    1986-08-01

    A compilation of whole-body counting existing across Canada was prepared by AECB (Atomic Energy Control Board) staff. This work was initiated so that AECB staff and other concerned parties would have this information readily available, especially during urgent situations. This report is to be used for reference purposes only, as it makes no attempt to judge the present state of the art of whole-body counting

  4. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  5. Factors preceding CRM readiness in small- and medium-sized tourism enterprises

    Directory of Open Access Journals (Sweden)

    Dinesh Vallabh

    2015-07-01

    Full Text Available Orientation: Customer relationship management (CRM is important to organisations striving for competitive advantage through building relationships with their customers. Research purpose: This study identified the factors preceding CRM and assessed selected South African small- and medium-sized tourism enterprises’ (SMTEs readiness for CRM. Motivation: CRM is likely to enhance SMTEs’ competitiveness. However, successful adoption and implementation of CRM is unlikely unless the organisation is ready for it. Research design, approach and method: A quantitative research approach and survey questionnaire yielded primary data from 332 respondent organisations selected by systematic sampling. Exploratory factor analysis was used to identify the latent factors preceding CRM readiness. Organisational CRM readiness was assessed based on CRM maturity in terms of data collection, use and sharing throughout the organisation. Main findings: Respondent-organisations performed well on the four factors preceding CRM readiness − business strategy, customer strategy, touch points and competencies, skills and technology and also on data collections and use, but not on data sharing. Practical/Managerial implications: CRM practice is believed to assist organisations in tailoring products and services to customers’ needs, providing customer satisfaction, enhancing customer retention and ultimately improving the organisation’s competitiveness and profitability. CRM might fail if SMTEs do not have CRM-enabling conditions in place and a CRM readiness audit should therefore be performed. Contribution: The study contributes to a largely under-researched area concerning CRM in SMTEs by providing an improved understanding of the factors that will enable SMTEs to engage in CRM activities.

  6. Body size shifts and early warning signals precede the historic collapse of whale stocks.

    Science.gov (United States)

    Clements, Christopher F; Blanchard, Julia L; Nash, Kirsty L; Hindell, Mark A; Ozgul, Arpat

    2017-06-22

    Predicting population declines is a key challenge in the face of global environmental change. Abundance-based early warning signals have been shown to precede population collapses; however, such signals are sensitive to the low reliability of abundance estimates. Here, using historical data on whales harvested during the 20th century, we demonstrate that early warning signals can be present not only in the abundance data, but also in the more reliable body size data of wild populations. We show that during the period of commercial whaling, the mean body size of caught whales declined dramatically (by up to 4 m over a 70-year period), leading to early warning signals being detectable up to 40 years before the global collapse of whale stocks. Combining abundance and body size data can reduce the length of the time series required to predict collapse, and decrease the chances of false positive early warning signals.

  7. Comparison of whole-body-imaging methods

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hoffer, P.

    1977-01-01

    Currently there are four different devices that have found clinical utility in whole-body imaging. These are the rectilinear scanner, the multicrystal whole-body scanner, the Anger-type camera with a whole-body-imaging table, and the tomoscanner. In this text, the basic theory of operation and a discussion of the advantages and disadvantages in whole-body imaging is presented for each device. When applicable, a comparative assessment of the various devices is also presented. As with all else in life, there is no simple answer to the question ''which total body imaging device is best.'' Institutions with a very heavy total-body-imaging load may prefer to use an already available dual-headed rectilinear scanner system for these studies, rather than invest in a new instrument. Institutions with moderate total-body-imaging loads may wish to invest in moving table or moving camera devices which make total body imaging more convenient but retain the basic flexibility of the camera. The large-field Anger camera with or without motion offers another flexible option to these institutions. The laboratory with a very heavy total body imaging load may select efficiency over flexibility, thereby freeing up other instruments for additional studies. Finally, reliability as well as availability and quality of local service must be considered. After all, design features of an instrument become irrelevant when it is broken down and awaiting repair

  8. Whole-body PET/MRI

    DEFF Research Database (Denmark)

    Aznar, M C; Sersar, Rachida; Saabye, J

    2014-01-01

    PURPOSE: In combined PET/MRI standard PET attenuation correction (AC) is based on tissue segmentation following dedicated MR sequencing and, typically, bone tissue is not represented. We evaluate PET quantification in whole-body (WB)-PET/MRI following MR-AC without considering bone attenuation...

  9. Whole Body Melanoma Transcriptome Response in Medaka.

    Directory of Open Access Journals (Sweden)

    Manfred Schartl

    Full Text Available The incidence of malignant melanoma continues to increase each year with poor prognosis for survival in many relapse cases. To reverse this trend, whole body response measures are needed to discover collaborative paths to primary and secondary malignancy. Several species of fish provide excellent melanoma models because fish and human melanocytes both appear in the epidermis, and fish and human pigment cell tumors share conserved gene expression signatures. For the first time, we have examined the whole body transcriptome response to invasive melanoma as a prelude to using transcriptome profiling to screen for drugs in a medaka (Oryzias latipes model. We generated RNA-seq data from whole body RNA isolates for controls and melanoma fish. After testing for differential expression, 396 genes had significantly different expression (adjusted p-value <0.02 in the whole body transcriptome between melanoma and control fish; 379 of these genes were matched to human orthologs with 233 having annotated human gene symbols and 14 matched genes that contain putative deleterious variants in human melanoma at varying levels of recurrence. A detailed canonical pathway evaluation for significant enrichment showed the top scoring pathway to be antigen presentation but also included the expected melanocyte development and pigmentation signaling pathway. Results revealed a profound down-regulation of genes involved in the immune response, especially the innate immune system. We hypothesize that the developing melanoma actively suppresses the immune system responses of the body in reacting to the invasive malignancy, and that this mal-adaptive response contributes to disease progression, a result that suggests our whole-body transcriptomic approach merits further use. In these findings, we also observed novel genes not yet identified in human melanoma expression studies and uncovered known and new candidate drug targets for further testing in this malignant melanoma

  10. Whole body MR imaging in diabetes

    International Nuclear Information System (INIS)

    Weckbach, Sabine; Schoenberg, Stefan O.

    2009-01-01

    Diabetes mellitus is a major cardiovascular risk factor and one of the major causes for morbidity and mortality worldwide. Diabetic complications have not only major impact on the quality of life of diabetic patients, but are also potentially life-threatening. Therefore prevention, diagnosis and therapy of these long-term complications are of high importance. However, diagnosis of the variety of complications from diabetes mellitus remains a diagnostic challenge and usually several diagnostic steps are necessary to diagnose or exclude these complications. In the last years whole body magnetic resonance imaging (WB-MRI) including whole body magnetic resonance angiography (WB-MRA) has been introduced for cardiovascular imaging and is now increasingly applied in clinical routine for the workup of patients with cardiovascular disease and for cardiovascular screening. The article summarizes rationales for WB-MRI in diabetes mellitus, technical concepts of disease specific cardiovascular WB-MRI in diabetes mellitus and discusses potential clinical consequences.

  11. Cardiovascular control during whole body exercise

    DEFF Research Database (Denmark)

    Volianitis, Stefanos; Secher, Niels H.

    2016-01-01

    It has been considered whether during whole body exercise the increase in cardiac output is large enough to support skeletal muscle blood flow. This review addresses four lines of evidence for a flow limitation to skeletal muscles during whole body exercise. First, even though during exercise...... the blood flow achieved by the arms is lower than that achieved by the legs (=160 vs. 385 mlmin1100 g1), the muscle mass that can be perfused with such flow is limited by the capacity to increase cardiac output (42 l/min, highest recorded value). Secondly, activation of the exercise pressor reflex during...... fatiguing work with one muscle group limits flow to other muscle groups. Another line of evidence comes from evaluation of regional blood flow during exercise where there is a discrepancy between flow to a muscle group when it is working exclusively and when it works together with other muscles. Finally...

  12. Whole-body monitoring: Goiania case, Brazil

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Dantas, B.M.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: individuals from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1); occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121, 57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was stablished according to the Cs activity present in the body or to the job that will be done. Some body burden activity curves for Cs 137 as a function of the time elapsed from the first measurement, are presented. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity X time curve. (author) [pt

  13. Whole-body gene expression pattern registration in Platynereis larvae.

    Science.gov (United States)

    Asadulina, Albina; Panzera, Aurora; Verasztó, Csaba; Liebig, Christian; Jékely, Gáspár

    2012-12-03

    Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere) of the Platynereis trochophore larva and used for the detailed study of neuronal development. Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2'-thiodiethanol (TDE), which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP) in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4'6-diamidino-2-phenylindole (DAPI). Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental stage. We then registered to these templates the

  14. Whole-body gene expression pattern registration in Platynereis larvae

    Directory of Open Access Journals (Sweden)

    Asadulina Albina

    2012-12-01

    Full Text Available Abstract Background Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere of the Platynereis trochophore larva and used for the detailed study of neuronal development. Results Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2’-thiodiethanol (TDE, which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4’6-diamidino-2-phenylindole (DAPI. Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental

  15. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  16. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  17. Whole body detectors for clinical applications

    International Nuclear Information System (INIS)

    Silar, J.

    The requirements are presented on the parameters of whole-body detectors suitable for clinical retention assays and the detector-patient configuration described. A whole-body detector was developed with an axial configuration of two pairs of large-volume scintillation detectors with NaI(Tl) crystals. One pair is placed under the bed, the other above the bed on which the patient is being examined. The axes of the crystals are located at a distance of 90 cm apart. The field of vision of the detector is described for the application of a 137 Cs source in the air and in a 24 cm layer of water. The positive characteristics of the detector are listed as being homogeneous sensitivity, energy resolution, long-term stability of signal pulse amplitude and average pulse rate in the integral mode. The results obtained show that the detector may be used to evaluate the level of contamination of persons by gamma emitters within the region of approximately 800 Bq to 74 MBq. The error in converting the number of signal pulses in the integral mode does not exceed 50% for gamma emitters with a photon energy above 30O keV. (J.B.)

  18. Whole-body hematocrit in polycythemia vera

    International Nuclear Information System (INIS)

    Valat, C.; Petat, E.; Besnard, J.C.

    1982-01-01

    To diagnose polycythemia vera, it is necessary to directly measure red-cell volume but it may be sometimes useful to know plasma volume too. The error following the indirect determination of plasma volume is evaluated the dispersion of corrosion factor representing the ratio of whole body hematocrit to venous hematocrit in normal subjects and patients with polycythemia vera is determined. The ratio is usually taken as being equal to 0.91, but even in normal subjects its value can vary from one to another by approximately +- 10 per cent. In polycythemia vera, the correction factor between whole-body hematocrit and venous hematocrit is not significant. So it is necessary to measure each compartment independently. Venous hematocrit is measured by a microhematocrit technique (CLAYS-ADAMS CT 3400) and red-cell and plasma volumes by following methods: approximately 10 ml of venous blood is withdrawn from the patient for labelling and centrifuged. The supernatant is discarded, one MBq 51 Cr is added to the packed cells and the mixture incubated at 37 0 C for 30 mn. The red cells are washed twice in saline and then injected with 0.2 MBq 125 I labelled human serum albumin

  19. Whole-body imaging of bone marrow.

    Science.gov (United States)

    Schmidt, Gerwin P; Reiser, Maximilian F; Baur-Melnyk, Andrea

    2009-06-01

    For bone marrow screening, multimodality algorithms including conventional radiographs, bone scintigraphy, multislice computed tomography CT (MS-CT) scan, and dedicated magnetic resonance imaging (MRI) are widely established in clinical routine. Although radiographs are used as a basic imaging procedure for clarification of suspected focal bone pathologies, low sensitivity has been reported for the detection of limited osteolytic bone marrow destruction. Therefore, skeletal scintigraphy often is used as a more sensitive and integrated method in patients with suspected malignant bone marrow disease. MS-CT scan is the method of choice in the assessment of bone stability and allows for evaluation of fracture risk. Hybrid imaging concepts, such as positron emission tomography-computed tomography (PET-CT) scan, have been established as an effective tool for the detection of skeletal metastases, using the additional metabolic information of a PET scan for the assessment of tumor viability and therapy response. MRI is an imaging technique that allows direct visualization of bone marrow components with high spatial resolution. The unique soft-tissue contrast of MRI enables precise assessment of bone marrow infiltration before osteolytic changes become visible in MS-CT or metabolic changes occur in bone scintigraphy or a PET scan. Furthermore it can depict tumor expansion into adjacent paraosseous structures, such as the spinal canal. The development of multichannel whole-body MRI (WB-MRI) systems has enabled bone marrow screening without use of ionizing radiation at high diagnostic accuracy. Parallel imaging techniques in combination with global matrix coil concepts, as well as the introduction of high-field whole-body scanners, have substantially reduced acquisition times without compromises in spatial resolution. WB-MRI has successfully been applied for screening of bone metastases and hematologic bone marrow diseases, like multiple myeloma, lymphoma, and histiocytosis X

  20. Myelopoiesis in whole-body-irradiated beagles

    International Nuclear Information System (INIS)

    Stevenson, A.F.G.

    1985-01-01

    The influence of dose-rate (DR) (either 5.2 or 52 cGy/min.) on the regeneration of bone marrow (BM) myelopoietic progenitor cells was studied in beagles after exposure to whole-body-irradiation (235, 375 and 1500 cGy + autologous BM-transplantation). Myelopoietic progenitor cells were assayed as colony-forming units in agar cultures (GM-CFU), in correlation with the colony-stimulation activity (CSA) in serum. At 235 cGy, the influence of DR on the recovery of GM-CFU was insignificant. However, at 375 cGy, the recovery was critically dependent on the DR. Depletion of GM-CFU numbers elevated CSA levels above pre-irradiation values. The DR determines the regenerative ability when the dose itself is critical to survival of the least number of hematopoietic stem cells (HSC) necessary for restitution. (author)

  1. Neural systemic impairment from whole-body vibration.

    Science.gov (United States)

    Yan, Ji-Geng; Zhang, Lin-ling; Agresti, Michael; LoGiudice, John; Sanger, James R; Matloub, Hani S; Havlik, Robert

    2015-05-01

    Insidious brain microinjury from motor vehicle-induced whole-body vibration (WBV) has not yet been investigated. For a long time we have believed that WBV would cause cumulative brain microinjury and impair cerebral function, which suggests an important risk factor for motor vehicle accidents and secondary cerebral vascular diseases. Fifty-six Sprague-Dawley rats were divided into seven groups (n = 8): 1) 2-week normal control group, 2) 2-week sham control group (restrained in the tube without vibration), 3) 2-week vibration group (exposed to whole-body vibration at 30 Hz and 0.5g acceleration for 4 hr/day, 5 days/week, for 2 weeks), 4) 4-week sham control group, 5) 4-week vibration group, 6) 8-week sham control group, and 7) 8-week vibration group. At the end point, all rats were evaluated in behavior, physiological, and brain histopathological studies. The cerebral injury from WBV is a cumulative process starting with vasospasm squeezing of the endothelial cells, followed by constriction of the cerebral arteries. After the 4-week vibration, brain neuron apoptosis started. After the 8-week vibration, vacuoles increased further in the brain arteries. Brain capillary walls thickened, mean neuron size was obviously reduced, neuron necrosis became prominent, and wide-ranging chronic cerebral edema was seen. These pathological findings are strongly correlated with neural functional impairments. © 2014 Wiley Periodicals, Inc.

  2. Whole body interaction with public displays

    CERN Document Server

    Walter, Robert

    2017-01-01

    This book develops valuable new approaches to digital out-of-home media and digital signage in urban environments. It offers solutions for communicating interactive features of digital signage to passers-by. Digital out-of-home media and digital signage screens are becoming increasingly interactive thanks to touch input technology and gesture recognition. To optimize their conversion rate, interactive public displays must 1) attract attention, 2) communicate to passers-by that they are interactive, 3) explain the interaction, and 4) provide a motivation for passers-by to interact. This book highlights solutions to problems 2 and 3 above. The focus is on whole-body interaction, where the positions and orientations of users and their individual body parts are captured by specialized sensors (e.g., depth cameras). The book presents revealing findings from a field study on communicating interactivity, a laboratory on analysing visual attention, a field study on mid-air gestures, and a field study on using mid-air...

  3. Whole body MR imaging in neurofibromatosis type 1

    Energy Technology Data Exchange (ETDEWEB)

    Meerbeeck, S.F.L. van [Department of Radiology and Medical Imaging, Ghent University, De Pintelaan 185, B-9000 Gent (Belgium)], E-mail: stephen.vm@rad-vanmeerbeeck.be; Verstraete, K.L. [Department of Radiology and Medical Imaging, Ghent University, De Pintelaan 185, B-9000 Gent (Belgium)], E-mail: koenraad.verstraete@ugent.be; Janssens, S.; Mortier, G. [Department of Medical Genetics, Ghent University Hospital, De Pintelaan 185, B-9000 Gent (Belgium)

    2009-02-15

    Objective: To assess the value of whole body MR imaging in patients with neurofibromatosis type 1 (NF1). Materials and methods: 24 patients (15-59 years; mean and median 36 years; 7 males; 17 females) with genetically proven neurofibromatosis type 1 were examined with whole body MR imaging. Axial and coronal T1- and fat-suppressed T2-weighted images (slice thickness 6-12 mm) were acquired on a 1.5 T MR unit (Symphony; Siemens, Erlangen, Germany). The images were reviewed by 2 radiologists: 1 senior, 1 junior. The criterion for a neurofibroma was a mass lesion with low signal intensity on T1 and high signal intensity on T2, along the course of a nerve. The location, size, general morphology and course along plexuses and nerves were evaluated. Cutaneous and subcutaneous neurofibromas were defined as 'superficial' neurofibromas. The other neurofibromas were regarded as 'deep' neurofibromas. Results: There were no major problems to differentiate neurofibromas from lymph nodes, vessels or cysts. The latter three were easily recognised by their typical shape and location, whereas neurofibromas occurred in regions where no mass lesion was anatomically expected. There was no relation between age and total number of neurofibromas throughout the body. Classification according to location and number of neurofibromas: 8 patients had only superficial neurofibromas, 1 only deep and 15 both superficial and deep lesions. Twelve patients had less than 15 neurofibromas and 12 had more. Classification according to course: in 8 patients the neurofibromas occurred along plexuses or proximal part of the intercostal nerves; in 16 patients the lesions were more peripheral. Classification according to morphology: 4 patients had plexiform neurofibromas and 20 patients had multiple solitary lesions. Twelve of these 20 patients had less than 15 lesions, and 8 had more. In 2 patients multiple solitary neurofibromas occurred along the nerve in a chain configuration. In one

  4. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    Science.gov (United States)

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  5. Calibration of the whole body counter at PSI

    International Nuclear Information System (INIS)

    Mayer, Sabine; Boschung, Markus; Fiechtner, Annette; Habegger, Ruedi; Meier, Kilian; Wernli, Christian

    2008-01-01

    At the Paul Scherrer Institut (PSI), measurements with the whole body counter are routinely carried out for occupationally exposed persons and occasionally for individuals of the population suspected of radioactive intake. In total about 400 measurements are performed per year. The whole body counter is based on a p-type high purity germanium (HPGe) coaxial detector mounted above a canvas chair in a shielded small room. The detector is used to detect the presence of radionuclides that emit photons with energies between 50 keV and 2 MeV. The room itself is made of iron from old railway rails to reduce the natural background radiation to 24 n Sv/h. The present paper describes the calibration of the system with the IGOR phantom. Different body sizes are realized by different standardized configurations of polyethylene bricks, in which small tubes of calibration sources can be introduced. The efficiency of the detector was determined for four phantom geometries (P1, P2, P4 and P6 simulating human bodies in sitting position of 12 kg, 24 kg, 70 kg and 110 kg, respectively. The measurements were performed serially using five different radionuclide sources ( 40 K, 60 Co, 133 Ba, 137 Cs, 152 Eu) within the phantom bricks. Based on results of the experiment, an efficiency curve for each configuration and the detection limits for relevant radionuclides were determined. For routine measurements, the efficiency curve obtained with the phantom geometry P4 was chosen. The detection limits range from 40 Bq to 1000 Bq for selected radionuclides applying a measurement time of 7 min. The proper calibration of the system, on one hand, is essential for the routine measurements at PSI. On the other hand, it serves as a benchmark for the already initiated characterisation of the system with Monte Carlo simulations. (author)

  6. Whole body computed tomographic findings of each one case with primary aldosteronism and Cushing syndrome

    International Nuclear Information System (INIS)

    Kamata, Shuji; Kawamura, Koro; Nakamura, Motoyuki

    1980-01-01

    We here report each one case with primary aldosteronism (male, 28 years old) and Cushing syndrome (female, 37 years old). Both of the cases showed characteristic clinical signs of hypertension and typical laboratory findings of adreno-hormonal assays. In performance of whole body computed tomography, clear pictures of tumorous adenomas in both cases were taken and the sizes of adenomas in picture were completely same as the masses obtained by the lateral adrenectomies. As a result, the whole body computed tomography is very useful to diagnose the diseases of adrenal adenoma and hyperplasia. (author)

  7. Whole body vibration exercise training for fibromyalgia.

    Science.gov (United States)

    Bidonde, Julia; Busch, Angela J; van der Spuy, Ina; Tupper, Susan; Kim, Soo Y; Boden, Catherine

    2017-09-26

    Exercise training is commonly recommended for adults with fibromyalgia. We defined whole body vibration (WBV) exercise as use of a vertical or rotary oscillating platform as an exercise stimulus while the individual engages in sustained static positioning or dynamic movements. The individual stands on the platform, and oscillations result in vibrations transmitted to the subject through the legs. This review is one of a series of reviews that replaces the first review published in 2002. To evaluate benefits and harms of WBV exercise training in adults with fibromyalgia. We searched the Cochrane Library, MEDLINE, Embase, CINAHL, PEDro, Thesis and Dissertation Abstracts, AMED, WHO ICTRP, and ClinicalTrials.gov up to December 2016, unrestricted by language, to identify potentially relevant trials. We included randomized controlled trials (RCTs) in adults with the diagnosis of fibromyalgia based on published criteria including a WBV intervention versus control or another intervention. Major outcomes were health-related quality of life (HRQL), pain intensity, stiffness, fatigue, physical function, withdrawals, and adverse events. Two review authors independently selected trials for inclusion, extracted data, performed risk of bias assessments, and assessed the quality of evidence for major outcomes using the GRADE approach. We used a 15% threshold for calculation of clinically relevant differences. We included four studies involving 150 middle-aged female participants from one country. Two studies had two treatment arms (71 participants) that compared WBV plus mixed exercise plus relaxation versus mixed exercise plus relaxation and placebo WBV versus control, and WBV plus mixed exercise versus mixed exercise and control; two studies had three treatment arms (79 participants) that compared WBV plus mixed exercise versus control and mixed relaxation placebo WBV. We judged the overall risk of bias as low for selection (random sequence generation), detection (objectively

  8. Whole-body MRI in the pediatric patient.

    Science.gov (United States)

    Ley, Sebastian; Ley-Zaporozhan, Julia; Schenk, Jens-Peter

    2009-06-01

    Whole-body MRI is a fast and accurate modality for detection and monitoring of disease throughout the entire body. For pediatric use the technique is of special interest twofold: first it is a radiological method without radiation exposure and second it allows for whole-body staging as well as for detailed local evaluation for surgical treatment thus reducing the number of examinations to be performed in sedation. In the pediatric population the technique is used for oncological, non-oncological (i.e. fever of unknown origin, osteonecrosis) staging and for disease severity assessment of syndromes affecting the whole body. These applications will be reviewed and imaging protocols will be presented.

  9. Whole-body MRI in the pediatric patient

    Energy Technology Data Exchange (ETDEWEB)

    Ley, Sebastian [Department of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Ruprecht-Karls-University Heidelberg (Germany)], E-mail: ley@gmx.de; Ley-Zaporozhan, Julia; Schenk, Jens-Peter [Department of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Ruprecht-Karls-University Heidelberg (Germany)

    2009-06-15

    Whole-body MRI is a fast and accurate modality for detection and monitoring of disease throughout the entire body. For pediatric use the technique is of special interest twofold: first it is a radiological method without radiation exposure and second it allows for whole-body staging as well as for detailed local evaluation for surgical treatment thus reducing the number of examinations to be performed in sedation. In the pediatric population the technique is used for oncological, non-oncological (i.e. fever of unknown origin, osteonecrosis) staging and for disease severity assessment of syndromes affecting the whole body. These applications will be reviewed and imaging protocols will be presented.

  10. Whole body scan system based on γ camera

    International Nuclear Information System (INIS)

    Ma Tianyu; Jin Yongjie

    2001-01-01

    Most existing domestic γ cameras can not perform whole body scan protocol, which is of important use in clinic. The authors designed a set of whole body scan system, which is made up of a scan bed, an ISA interface card controlling the scan bed and the data acquisition software based on a data acquisition and image processing system for γ cameras. The image was obtained in clinical experiment, and the authors think it meets the need of clinical diagnosis. Application of this system in γ cameras can provide whole body scan function at low cost

  11. Fluid and sodium loss in whole-body-irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Geraci, J.P.; Jackson, K.L.; Mariano, M.S.

    1987-09-01

    Whole-body and organ fluid compartment sizes and plasma sodium concentrations were measured in conventional, GI decontaminated, bile duct ligated, and choledochostomized rats at different times after various doses of gamma radiation. In addition, sodium excretion was measured in rats receiving lethal intestinal radiation injury. After doses which were sublethal for 3-5 day intestinal death, transient decreases occurred in all the fluid compartments measured (i.e., total body water, extracellular fluid space, plasma volume). No recovery of these fluid compartments was observed in rats destined to die from intestinal radiation injury. The magnitude of the decreases in fluid compartment sizes was dose dependent and correlated temporally with the breakdown and recovery of the intestinal mucosa but was independent of the presence or absence of enteric bacteria or bile acids. Associated with the loss of fluid was an excess excretion of 0.83 meq of sodium between 48 and 84 h postirradiation. This represents approximately 60% of the sodium lost from the extracellular fluid space in these animals during this time. The remaining extracellular sodium loss was due to redistribution of sodium to other spaces. It is concluded that radiation-induced breakdown of the intestinal mucosa results in lethal losses of fluid and sodium as evidenced by significant decreases in total body water, extracellular fluid space, plasma volume, and plasma sodium concentration, with hemoconcentration. These changes are sufficient to reduce tissue perfusion leading to irreversible hypovolemic shock and death.

  12. Changes in myonuclear domain size do not precede muscle hypertrophy during prolonged resistance-type exercise training.

    Science.gov (United States)

    Snijders, T; Smeets, J S J; van Kranenburg, J; Kies, A K; van Loon, L J C; Verdijk, L B

    2016-02-01

    Muscle fibre hypertrophy is accompanied by an increase in myonuclear number, an increase in myonuclear domain size or both. It has been suggested that increases in myonuclear domain size precede myonuclear accretion and subsequent muscle fibre hypertrophy during prolonged exercise training. In this study, we assessed the changes in muscle fibre size, myonuclear and satellite cell content throughout 12 weeks of resistance-type exercise training in young men. Twenty-two young men (23 ± 1 year) were assigned to a progressive, 12-weeks resistance-type exercise training programme (3 sessions per week). Muscle biopsies from the vastus lateralis muscle were taken before and after 2, 4, 8 and 12 weeks of exercise training. Muscle fibre size, myonuclear content, myonuclear domain size and satellite cell content were assessed by immunohistochemistry. Type I and type II muscle fibre size increased gradually throughout the 12 weeks of training (type I: 18 ± 5%, type II: 41 ± 6%, P muscle fibres. No changes in type I and type II myonuclear domain size were observed at any time point throughout the intervention. Satellite cell content increased significantly over time in both type I and type II muscle fibres (P muscle fibre hypertrophy during prolonged resistance-type exercise training in vivo in humans. © 2015 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  13. Exploring the effects of seated whole body vibration exposure on repetitive asymmetric lifting tasks.

    Science.gov (United States)

    Mehta, Jay P; Lavender, Steven A; Jagacinski, Richard J; Sommerich, Carolyn M

    2015-01-01

    This study investigated changes in the physiological and behavioral responses to repetitive asymmetric lifting activity after exposure to whole body vibrations. Seventeen healthy volunteers repeatedly lifted a box (15% of lifter's capacity) positioned in front of them at ankle level to a location on their left side at waist level at the rate of 10 lifts/min for a period of 60 minutes. Prior to lifting, participants were seated on a vibrating platform for 60 minutes; in one of the two sessions the platform did not vibrate. Overall, the physiological responses assessed using near-infrared spectroscopy signals for the erector spinae muscles decreased significantly over time during the seating and the lifting tasks (p < 0.001). During repetitive asymmetric lifting, behavioral changes included increases in peak forward bending motion, twisting movement, and three-dimensional movement velocities of the spine. The lateral bending movement of the spine and the duration of each lift decreased significantly over the 60 minutes of repetitive lifting. With exposure to whole body vibration, participants twisted farther (p = 0.046) and twisted faster (p = 0.025). These behavioral changes would suggest an increase in back injury risk when repetitive lifting tasks are preceded by whole body vibration exposure.

  14. Correction factor for potassium-40 whole-body counting

    Energy Technology Data Exchange (ETDEWEB)

    Kinase, Sakae [Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    1999-10-01

    Correction factors, correlation between {sup 40}K whole-body counting efficiencies and a simple physical parameter, were determined using Monte Carlo simulation. The surface area of a subject was adopted as the correction factor parameter for practical routine use in the interpretation of response functions from the subject, and from the relationship between the surface area and counting efficiencies of a whole-body counter a correction equation was derived. To testify the feasibility of the correction factor, the {sup 40}K contents in the total body of Japanese male adults were measured with a whole-body counter, and the {sup 40}K contents corrected by using the correction equation were compared with those estimated with a bioelectrical impedance instrument. The quantitative agreement of the {sup 40}K contents corrected by whole-body counting with those estimated by means of the bioelectrical impedance instrument is fairly good. The response function and counting efficiency of the whole-body counter to a {sup 40}K phantom were obtained by calculation and actual measurement. It was found that calculation by the EGS4 code agrees very well with the measurement. (author)

  15. A calibration method for whole-body counters, using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Ishikawa, T.; Matsumoto, M.; Uchiyama, M.

    1996-01-01

    A Monte Carlo simulation code was developed to estimate the counting efficiencies in whole-body counting for various body sizes. The code consists of mathematical models and parameters which are categorised into three groups: a geometrical model for phantom and detectors, a photon transport model, and a detection system model. Photon histories were simulated with these models. The counting efficiencies for five 137 Cs block phantoms of different sizes were calculated by the code and compared with those measured with a whole-body counter at NIRS (Japan). The phantoms corresponded to a newborn, a 5 month old, a 6 year old, and 11 year old and an adult. The differences between the measured and calculated values were within 6%. For the adult phantom, the difference was 0.5%. The results suggest that the Monte Carlo simulation code can be used to estimate the counting efficiencies for various body sizes. (Author)

  16. A calibration method for whole-body counters, using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T.; Matsumoto, M.; Uchiyama, M. [National Inst. of Radiological Sciences, Chiba (Japan)

    1996-11-01

    A Monte Carlo simulation code was developed to estimate the counting efficiencies in whole-body counting for various body sizes. The code consists of mathematical models and parameters which are categorised into three groups: a geometrical model for phantom and detectors, a photon transport model, and a detection system model. Photon histories were simulated with these models. The counting efficiencies for five {sup 137}Cs block phantoms of different sizes were calculated by the code and compared with those measured with a whole-body counter at NIRS (Japan). The phantoms corresponded to a newborn, a 5 month old, a 6 year old, and 11 year old and an adult. The differences between the measured and calculated values were within 6%. For the adult phantom, the difference was 0.5%. The results suggest that the Monte Carlo simulation code can be used to estimate the counting efficiencies for various body sizes. (Author).

  17. Whole-body impedance control of wheeled humanoid robots

    CERN Document Server

    Dietrich, Alexander

    2016-01-01

    Introducing mobile humanoid robots into human environments requires the systems to physically interact and execute multiple concurrent tasks. The monograph at hand presents a whole-body torque controller for dexterous and safe robotic manipulation. This control approach enables a mobile humanoid robot to simultaneously meet several control objectives with different pre-defined levels of priority, while providing the skills for compliant physical contacts with humans and the environment. After a general introduction into the topic of whole-body control, several essential reactive tasks are developed to extend the repertoire of robotic control objectives. Additionally, the classical Cartesian impedance is extended to the case of mobile robots. All of these tasks are then combined and integrated into an overall, priority-based control law. Besides the experimental validation of the approach, the formal proof of asymptotic stability for this hierarchical controller is presented. By interconnecting the whole-body ...

  18. The whole-body counter of the radiation centre Giessen

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    The layout of the whole-body counter at the institute for biophysics of the Giessen radiation centre is decribed. With suitable collimators, the whole-body counter may be used to determine the radioactivity in human and animal organs. The shielding and the measuring and waiting rooms for the patients are described with regard to their technical details. The whole-body counting system enables the radioactivity and the retention of various radioisotopes (e.g. 58 Co-vitamin B 12 , 40 K, 54 Mn, 137 Co, 131 J, 22 Na) to be measured. The estimation of the radiation exposure due to different types of examinations in nuclear medicine, in terms of the critical organs for each type of examination, is very accurate with this counting device. (GSE) [de

  19. Whole body MRI in children; Ganzkoerper-MRT bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Juergen F.; Tsiflikas, Ilias [Tuebingen Univ. (Germany). Bereich Kinderradiologie

    2014-09-15

    In pediatric patients whole body MRI has a relevant impact on both, diagnostic work-up and treatment. Using adapted sequence protocols comprehensive imaging without radiation exposure is possible avoiding additional examinations in many cases. Especially in bone marrow the differentiation between normal and abnormal finding can be difficult, therefore the knowledge of normal maturing of organs is important. Whole body diffusion weighted imaging particularly in neuroblastomas or sarcomas improves the low specificity of conventional MR-protocols. Technical prerequisites, examination protocol and strategies, image interpretation, indications and clinical relevance as well as advantages and disadvantages of whole body MRI will be discussed on the basis of application-oriented cases and the literature.

  20. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1990-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  1. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1991-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV) ane....... This anesthetic technique and the stethoscope have been used in seven children. The total IV anesthesia proved to be a useful method for children during whole body radiation. The modified stethoscope functioned very well and was a useful complement to the monitoring equipment....

  2. Sympathetic nerve activity and whole body heat stress in humans

    OpenAIRE

    Low, David A.; Keller, David M.; Wingo, Jonathan E.; Brothers, R. Matthew; Crandall, Craig G.

    2011-01-01

    We and others have shown that moderate passive whole body heating (i.e., increased internal temperature ∼0.7°C) increases muscle (MSNA) and skin sympathetic nerve activity (SSNA). It is unknown, however, if MSNA and/or SSNA continue to increase with more severe passive whole body heating or whether these responses plateau following moderate heating. The aim of this investigation was to test the hypothesis that MSNA and SSNA continue to increase from a moderate to a more severe heat stress. Th...

  3. Effect of whole-body vibration therapy on performance recovery.

    Science.gov (United States)

    Manimmanakorn, Nuttaset; Ross, Jenny J; Manimmanakorn, Apiwan; Lucas, Samuel J; Hamlin, Michael J

    2015-04-01

    To compare whole-body vibration (WBV) with traditional recovery protocols after a high-intensity training bout. In a randomized crossover study, 16 athletes performed 6 × 30-s Wingate sprints before completing either an active recovery (10 min of cycling and stretching) or WBV for 10 min in a series of exercises on a vibration platform. Muscle hemodynamics (assessed via near-infrared spectroscopy) were measured before and during exercise and into the 10-min recovery period. Blood lactate concentration, vertical jump, quadriceps strength, flexibility, rating of perceived exertion (RPE), muscle soreness, and performance during a single 30-s Wingate test were assessed at baseline and 30 and 60 min postexercise. A subset of participants (n = 6) completed a 3rd identical trial (1 wk later) using a passive 10-min recovery period (sitting). There were no clear effects between the recovery protocols for blood lactate concentration, quadriceps strength, jump height, flexibility, RPE, muscle soreness, or single Wingate performance across all measured recovery time points. However, the WBV recovery protocol substantially increased the tissue-oxygenation index compared with the active (11.2% ± 2.4% [mean ± 95% CI], effect size [ES] = 3.1, and -7.3% ± 4.1%, ES = -2.1 for the 10 min postexercise and postrecovery, respectively) and passive recovery conditions (4.1% ± 2.2%, ES = 1.3, 10 min postexercise only). Although WBV during recovery increased muscle oxygenation, it had little effect in improving subsequent performance compared with a normal active recovery.

  4. The effect of whole body vibration exercise on muscle activation ...

    African Journals Online (AJOL)

    African Journal for Physical Activity and Health Sciences ... The effect of whole body vibration exercise (WBV) on muscle activation has recently been a topic for discussion amongst some researchers. ... Participants then performed two different exercises: standing calf raises and prone bridging, without and with WBV.

  5. Whole-Body and Hepatic Insulin Resistance in Obese Children

    Science.gov (United States)

    Ibarra-Reynoso, Lorena del Rocío; Pisarchyk, Liudmila; Pérez-Luque, Elva Leticia; Garay-Sevilla, Ma. Eugenia; Malacara, Juan Manuel

    2014-01-01

    Background Insulin resistance may be assessed as whole body or hepatic. Objective To study factors associated with both types of insulin resistance. Methods Cross-sectional study of 182 obese children. Somatometric measurements were registered, and the following three adiposity indexes were compared: BMI, waist-to-height ratio and visceral adiposity. Whole-body insulin resistance was evaluated using HOMA-IR, with 2.5 as the cut-off point. Hepatic insulin resistance was considered for IGFBP-1 level quartiles 1 to 3 (HOMA-IR was negatively associated with IGFBP-1 and positively associated with BMI, triglycerides, leptin and mother's BMI. Girls had increased HOMA-IR. IGFBP-1 was negatively associated with waist-to-height ratio, age, leptin, HOMA-IR and IGF-I. We did not find HOMA-IR or IGFBP-1 associated with fatty liver. Conclusion In school-aged children, BMI is the best metric to predict whole-body insulin resistance, and waist-to-height ratio is the best predictor of hepatic insulin resistance, indicating that central obesity is important for hepatic insulin resistance. The reciprocal negative association of IGFBP-1 and HOMA-IR may represent a strong interaction of the physiological processes of both whole-body and hepatic insulin resistance. PMID:25411786

  6. Whole Body Bone Tissue and Cardiovascular Risk in Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Claudiu Popescu

    2014-01-01

    Full Text Available Introduction. Atherosclerosis and osteoporosis share an age-independent bidirectional correlation. Rheumatoid arthritis (RA represents a risk factor for both conditions. Objectives. The study aims to evaluate the connection between the estimated cardiovascular risk (CVR and the loss of bone tissue in RA patients. Methods. The study has a prospective cross-sectional design and it includes female in-patients with RA or without autoimmune diseases; bone tissue was measured using whole body dual X-ray absorptiometry (wbDXA; CVR was estimated using SCORE charts and PROCAM applications. Results. There were 75 RA women and 66 normal women of similar age. The wbDXA bone indices correlate significantly, negatively, and age-independently with the estimated CVR. The whole body bone percent (wbBP was a significant predictor of estimated CVR, explaining 26% of SCORE variation along with low density lipoprotein (P < 0.001 and 49.7% of PROCAM variation along with glycemia and menopause duration (P < 0.001. Although obese patients had less bone relative to body composition (wbBP, in terms of quantity their bone content was significantly higher than that of nonobese patients. Conclusions. Female patients with RA and female patients with cardiovascular morbidity have a lower whole body bone percent. Obese female individuals have higher whole body bone mass than nonobese patients.

  7. Whole-body microvascular permeability of small molecules in man

    DEFF Research Database (Denmark)

    Henriksen, J H

    1985-01-01

    In order to estimate whole-body permeability-surface area (PS) product, the initial slope of the plasma disappearance curve was determined after simultaneous i.v. injection of 24Na+ (mol.wt 24) and 51Cr-EDTA (mol.wt 342). Twelve subjects were studied. Plasma volume (PV) was measured by the indica...

  8. Whole-body vibration dosage alters leg blood flow

    NARCIS (Netherlands)

    Lythgo, Noel; Eser, Prisca; de Groot, Patricia; Galea, Mary

    The effect of whole-body vibration dosage on leg blood flow was investigated. Nine healthy young adult males completed a set of 14 random vibration and non-vibration exercise bouts whilst squatting on a Galileo 900 plate. Six vibration frequencies ranging from 5 to 30 Hz (5 Hz increments) were used

  9. The effect of whole-body vibration training on selected ...

    African Journals Online (AJOL)

    The information on the use of whole-body vibration training (WBVT) on some health-related risk factors such as body composition and biochemical parameters is limited. The purpose of the study was therefore, to assess the effect of progressive WBVT on selected anthropometric and biochemical parameters in healthy ...

  10. Effects of whole body vibration intervention on handgrip strength of ...

    African Journals Online (AJOL)

    Effects of whole body vibration intervention on handgrip strength of Brazilian healthy soldiers. Danielle Soares Morel, Eloá Moreira-Marconi, Samuel Brandão Sobrinho Neto, Laisa Liane Paineiras Domingos, Patrícia Lopes de Souza, Danúbia da Cunha de Sá Caputo, Glenda Dias Costa, Cláudia Ferreira de Figueiredo, ...

  11. Exercise Enhances Whole-Body Cholesterol Turnover in Mice

    NARCIS (Netherlands)

    Meissner, Maxi; Havinga, Rick; Boverhof, Renze; Kema, Ido; Groen, Albert K.; Kuipers, Folkert

    MEISSNER, M., R. HAVINGA, R. BOVERHOF, I. KEMA, A. K. GROEN, and F. KUIPERS. Exercise Enhances Whole-Body Cholesterol Turnover in Mice. Med. Sci. Sports Exerc., Vol. 42, No. 8, pp. 1460-1468, 2010. Purpose: Regular exercise reduces cardiovascular risk in humans by reducing cholesterol levels, but

  12. Detection of metastatic thyroid carcinoma through whole body counting

    International Nuclear Information System (INIS)

    Novenario, H.S.; Pascacio, F.M.; Cruz, Benjamin de la; Anden, A.B.

    Whole body counters are not only used in measuring radioactivity in the body for radiation protection purposes but also in the measurement of iron absorption, body potassium and cesium, chronic blood loss, and also in the determination of the effectiveness of surgery, thyroid hormone and radioactive iodine therapy in thyroid carcinoma. This report deals with our experience in the use of a shadow-shield whole body counter in the determination of I-131 uptake by metastatic lesions of cancer of thyroid after total thyroidectomy and ablation therapy with I-131. This study was undertaken jointly by the Department of Nuclear Medicine, Veterans Memorial Hospital and the Biomedical Research Division of the Philippine Atomic Energy Commission. Preliminary results indicate that the 22 patients who underwent whole body counting after total thyroidectomy I-131 ablation therapy, 9 patients had elevated percentage retention of I-131, 10 patients with normal values and 3 patients with rising values. Foci of I-131 concentration in those with elevated and rising percentage concentration values were seen in the thyroidal bed scintiscans, while the 10 patients with normal values had negative scintiscans. The results of our observations confirm the results obtained by other workers abroad. Our preliminary results indicate that with the use of whole body counters a sensitive method of assessing whether functioning metastatic lesion of cancer of the thyroid still exist after total thyroidectomy and I-131 ablation therapy can be provided. (author)

  13. Anesthesia and monitoring during whole body radiation in children

    DEFF Research Database (Denmark)

    Henneberg, S; Nilsson, A; Hök, B

    1991-01-01

    During whole body radiation therapy of children, treatment may be done in places not equipped with acceptable scavenging systems for anesthetic gases and where clinical observation of the patient may be impossible. In order to solve this problem, the authors have used a total intravenous (IV...

  14. Whole body vibration exposure patterns in Canadian prairie farmers.

    Science.gov (United States)

    Zeng, Xiaoke; Kociolek, Aaron M; Khan, Muhammad Idrees; Milosavljevic, Stephan; Bath, Brenna; Trask, Catherine

    2017-08-01

    Whole body vibration is a significant physical risk factor associated with low back pain. This study assessed farmers' exposure to whole body vibration on the Canadian prairies according to ISO 2631-1. Eighty-seven vibration measurements were collected with a triaxial accelerometer embedded in a rubber seat pad at the operator-seat interface of agricultural machinery, including tractors, combines, pickup trucks, grain trucks, sprayers, swathers, all-terrain vehicles, and skid steers. Whole body vibration was highest in the vertical axis, with a mean (range) frequency-weighted root mean squared acceleration of 0.43 m/s 2 (0.19-1.06 m/s 2 ). Mean crest factors exceeded 9 in all 3 axes, indicating high mechanical shock content. The vertical axis vibration dose value was 7.55 m/s 1.75 (2.18-37.59 m/s 1.75 ), with 41.4% of measurements within or above the health guidance caution zone. These high exposures in addition to an ageing agricultural workforce may increase health risks even further, particularly for the low back. Practitioner Summary: Agricultural workers are frequently exposed to whole body vibration while operating farm equipment, presenting a substantial risk to musculoskeletal health including the low back. Assessing vibration exposure is critical in promoting a safe occupational environment, and may inform interventions to reduce farmer's exposure to vibration.

  15. Positive whole-body /sup 67/Ga scintigraphy in dermatomyositis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, W.P.; Robinson, R.G.; Gobuty, A.H.

    1979-07-01

    Gallium-67 has proven useful in the evaluation of the extent of several malignancies, including bronchogenic carcinoma, Hodgkin's disease, and lymphoma. Many infectious processes also yield positive scans, including sarcoidosis, pneumonia, pyelonephritis, and active tuberculosis. We report a patient in whom whole-body /sup 67/Ga scintimaging led to the diagnosis of dermatomyositis.

  16. Whole body vibration improves attention and motor performance in ...

    African Journals Online (AJOL)

    Background: Whole body vibration (WBV) is a form of physical stimulation via mechanical vibrations transmitted to a subject. It is assumed that WBV induces sensory stimulation in cortical brain regions through the activation of skin and muscle receptors responding to the vibration. The effects of WBV on muscle strength are ...

  17. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  18. The A.R.L. whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1990-02-01

    This report describes a Whole Body Monitor based on four uncollimated NaI(Tl) detectors in a static geometry in use at the Australian Radiation Laboratory. A detailed discussion is presented on the methodology used to estimate the detector efficiency for any arbitrary source whose shape can be described analytically. This procedure is valid for photon emitters in the range 120 keV to 2.6 MeV. By the use of simple geometric models, this approach is applied to the whole body as well as for certain internal organs. For lower photon energies, a discussion of methods using NaI(Tl) detectors to detect in-vivo sources by analysis of pulse-height spectra, is presented. In addition, the application of the Whole Body Monitor in the study of human calcium metabolism, using the tracer 47 Ca is described. Results of measurments on the natural activity of possible candidates for components of the concrete base of the Whole Body Monitor are presented. 74 refs., 22 tabs., 40 figs

  19. Dynamic whole body PET parametric imaging: II. Task-oriented statistical estimation

    Science.gov (United States)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-01-01

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15–20cm) of a single bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate Ki and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final Ki parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion study

  20. Whole-body counting of Fukushima residents after the TEPCO Fukushima Daiichi Nuclear Power Station accident

    International Nuclear Information System (INIS)

    Momose, Takumaro; Takada, Chie; Nakagawa, Takahiro; Nakai, Katsuta; Kurihara, Osamu; Tsujimura, Norio; Furuta, Sadaaki; Ohi, Yoshihiro; Murayama, Takashi; Suzuki, Takashi; Uezu, Yasuhiro

    2012-01-01

    At the request of the Fukushima government, the Japan Atomic Energy Agency (JAEA) started whole-body counting of residents on July 11, 2011, to assess radiation exposure after the TEPCO Fukushima Daiichi Nuclear Power Station accident. JAEA has examined residents in Iitate, Kawamata, Namie, and eight other local communities. The measurement capacity of the whole-body counting device is approximately 100 persons per day, and the total number of people to measure reached 9,927 by the end of January 2012. Two types of whole-body counter (WBC), each of which has two large-sized NaI(Tl) detectors, were used to perform the measurements. Physical phantoms (a Canberra RMC-II transfer phantom or a water-filled block phantom developed by JAEA) were used to perform the efficiency calibration of the WBCs, and results of this calibration were verified by comparing them with different-sized BOttle Mannequin ABsorber (BOMAB) phantoms imitating an adult male, a 10-year-old child, and a 4-year-old child. Short half-life radionuclides (e.g., 131 I) originating from the accident were not detected in the present work, because the measurements were made starting four months after the accident. These measurements showed that about 80% of the residents were below a minimum detectable amount (MDA) of the measured radionuclides in the whole-body content. No artificial nuclides other than 134 Cs and 137 Cs were detected in the present whole-body counting. The maximum whole-body content of radiocesium ( 134 Cs and 137 Cs in total) was 2.7 kBq for children ( 137 Cs/ 134 Cs) was estimated to be from 1.12 to 1.26. An acute intake scenario via inhalation of radiocesium was assumed in the present dose estimation for all the residents who were measured by the end of January 2012. The committed effective dose (CED) to 99.8% of the residents was found to be below 1 mSv. There were only 25 subjects with a CED greater than 1 mSv, and the maximum CED recorded was 3 mSv. The extrapolated 50th percentile

  1. History and development of whole body counting in Brazil

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Nogueira de Oliveira, C.A.; Lourenco, M.C.; Lipsztein, J.L.; Guidicini, O.Y.M.; Antunes, I.M.

    1993-01-01

    The first whole body counter (WBC) built in Brazil used sugar as shielding material, and for this reason became internationally known as the open-quotes Sugar Bowl.close quotes The main purpose of building that first WBC was to detect natural gamma emitters other than 40 K in the inhabitants of Guarapari, then a small fishing village with a population not greater than 6,000 people, suspected of having long-lived contamination with natural radionuclides of the 232 Th and 238 U series. However, the Sugar Bowl was also used to whole body count the workers of a gas mantle factory. This paper reviews the history behind the construction and uses of the Sugar Bowl, as well as presents a brief view of the basic characteristics of the subsequent WBCs built in Brazil. A total of 12 WBCs have been in existence in this country until today

  2. Refrigerator operating experience on whole body MRI magnet systems

    International Nuclear Information System (INIS)

    Murray, F.S.; Hwang, K.F.; Markiewicz, W.D.

    1986-01-01

    Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented

  3. Whole-Body Impedance Control of Wheeled Humanoid Robots

    OpenAIRE

    Dietrich, Alexander

    2015-01-01

    Introducing mobile humanoid robots into human environments requires the systems to realize soft physical contacts. In this context, the thesis presents a whole-body robot controller for dexterous physical interaction. The approach enables the robot to perform several control tasks at the same time while following a given order of priority. The theoretical results are experimentally validated on a mobile, torque-controlled humanoid robot. Relevant fields of application are service robotics or ...

  4. Whole body vibrations during field operations in the vineyard

    Directory of Open Access Journals (Sweden)

    Pietro Catania

    2013-09-01

    Full Text Available Human exposure to mechanical vibration can be a significant risk factor for exposed workers and this also occurs in the agricultural sector, in particular with reference to the driver of the tractor during field operations. The aim of this paper is the evaluation of Whole Body Vibrations for the operator driving tractors during the field operations in the vineyard. The experimental tests were performed using a wheeled and a track-laying tractor.

  5. Whole Body Vibration in Anterior Cruciate Ligament Rehabilitation

    OpenAIRE

    Vargas, Sara Ruby

    2011-01-01

    There has been an increasing prevalence of anterior cruciate ligament (ACL) injuries. In the literature describing ACL rehabilitation program flexibility, muscle strength, proprioception, and postural stability have been identified as reoccurring struggles that have arisen during rehabilitation. Whole Body Vibration (WBV) has been investigate as a rehabilitation tool that can be used when recovering from an ACL injury. Research has suggested that WBV can be used to increase flexibility, impro...

  6. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  7. Natural β-carotene and whole body irradiation in rats

    International Nuclear Information System (INIS)

    Ben-Amotz, A.; Rachmilevich, B.; Greenberg, S.; Sela, M.; Weshler, Z.

    1996-01-01

    β-Carotene and other carotenoids are reported to be potent free radical quenchers, singlet oxygen scavengers, and lipid antioxidants. Whole-body irradiation is known to cause an immunosuppression effect in mammals through the possible initiation and production of reactive oxygen species. We decided to test the possible antioxidative effect against whole-body irradiation of a natural β-carotene, composed of equal amounts of the all-trans and 9-cis isomers, obtained from the unicellular alga Dunaliella bardawil. Rats were fed on ground commercial food enriched with natural β-carotene (50 mg/kg diet). On completion of 1 week with β-carotene, the rats were exposed to a single dose of 4 Gy whole-body irradiation, after which their livers and blood were removed for β-carotene and retinol analysis in comparison with control livers of animals irradiated or not, or supplemented with β-carotene after irradiation. A normal increase in body weight with no ill effects was noted in the groups of rats whose diet was supplemented by β-carotene before and after irradiation, compared with the reduction in the specific growth rate in the group of rats irradiated without β-carotene. Liver β-carotene and retinol decreased significantly after irradiation compared with the rats which were not irradiated. This decrease was not shown in rats fed β-carotene prior to irradiation, and the effect of irradiation was partially cured by supplementation with β-carotene after irradiation. High-pressure liquid chromatography (HPLC) analysis of the irradiated animals showed a selective decline in 9-cis β-carotene and in retinol over all-trans β-carotene and retinyl esters. These results suggest that 9-cis β-carotene and retinol protect in vivo against the cellular damage by free radicals induced after whole-body irradiation. (orig.). With 1 fig., 2 tabs

  8. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  9. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  10. Measurements of whole-body radioactivity in the UK population

    International Nuclear Information System (INIS)

    Fenwick, J.D.; Boddy, K.; McKenzie, A.L.; Oxby, C.B.

    1992-01-01

    A national survey of whole-body radioactivity was undertaken. A mobile whole-body counter visited collaborating Medical Physics Departments and Hospitals in England and Wales. Data were also obtained from an installed whole-body counter at the West Cumberland Hospital, Whitehaven, and from a control site at Addenbrooke's Hospital, Cambridge. 1657 volunteer members of the public were measured, including 162 children. 36% of volunteers had been measured in a similar survey 2 years earlier, and showed between a two and five fold reduction in body radiocaesium. No radiocaesium was detected in 54% of people measured. Measurements showed a progressive fall over the course of the study, reaching a baseline of 0.3 Bq 137 Cs/gK. In 1989, the additional radiation dose incurred from radiocaesium varied from a maximum of 4.1 μSv in Cumbria to 1.5 μSv in the South East, compared with the average annual radiation dose of 2500 μSv due to all other causes. No other gamma-emitting radionuclides were found. Results are consistent with Chernobyl as the source of the radiocaesium detected. (author)

  11. MONICA: a compact, portable dual gamma camera system for mouse whole-body imaging

    International Nuclear Information System (INIS)

    Xi, Wenze; Seidel, Jurgen; Kakareka, John W.; Pohida, Thomas J.; Milenic, Diane E.; Proffitt, James; Majewski, Stan; Weisenberger, Andrew G.; Green, Michael V.; Choyke, Peter L.

    2010-01-01

    Introduction: We describe a compact, portable dual-gamma camera system (named 'MONICA' for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods: Two identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed 'looking up' through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results: Tc-99m performance measurements, using a photopeak energy window of 140 keV±10%, yielded the following results: spatial resolution (FWHM at 1 cm), 2.2 mm; sensitivity, 149 cps (counts per seconds)/MBq (5.5 cps/μCi); energy resolution (FWHM, full width at half maximum), 10.8%; count rate linearity (count rate vs. activity), r 2 =0.99 for 0-185 MBq (0-5 mCi) in the field of view (FOV); spatial uniformity, <3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-min images acquired throughout the 168-h study period. Conclusion: Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g., limited imaging space, portability and, potentially, cost are important.

  12. Dynamics of human whole body amino acid metabolism

    International Nuclear Information System (INIS)

    Young, V.R.

    1981-01-01

    The mechanism of regulation of the nitrogen metabolism in humans under various nutritional and physiological states was examined using stable isotopes. In the simultaneous continuous infusion of 1- [ 13 ] - leucine and α- [ 15 N]- lysine, their fluxed decreased when individuals received lower protein intake. The rates of oxidation and incorporation into body proteins of leucine changed in parallel with the protein intake. Such effects of diet on whole body leucine kinetics were modified by the energy state and dietary energy level. The nitrogen balance was also improved by an excess level of dietary energy. When the intake of dietary protein was lowered below the maintenance level, the whole body flux and de novo synthesis of glycine were lowered, but alanine synthesis was clearly increased. The intravenous infusion of glucose at 4 mg/kg.min, which causes increase in excess blood sugar and plasma insulin, increased the alanine flux, but had no effect on the glycine flux. The rate of albumin synthesis, determined by giving 15 N-glycine orally every 3 hr, decreased with the lowered intake of dietary protein in young men, but not in elderly men. This explains why the serum albumin synthesis increases with the increase in the intake of dietary protein in young men, but not in elderly men. The rate of whole body protein synthesis in young men receiving the L-amino acid diets providing with the required intake of specific amino acid was much lower than that in the men receiving the diets providing with generous intake of specific amino acid. Thus the control mechanism to maintain the homeostasis of body nitrogen and amino acids is related in some unknown way to the nutritional requirement of the hosts. (Kaihara, S.)

  13. Joint accumulations of FDG in whole body PET scans

    Energy Technology Data Exchange (ETDEWEB)

    Schulthess, G.K. von; Meier, N.; Stumpe, K.D.M. [Dept. of Medical Radiology: Nuclear Medicine, Univ. Hospital of Zurich (Switzerland)

    2001-12-01

    Purpose: To retrospectively evaluate FDG accumulations in major joints in a large series of non-absorption corrected partial body and whole body FDG-PET scans, and to determine the frequency and intensity of accumulation. Materials and methods: 354 consecutive PET partial- and whole body non-transmission corrected scans of patients obtained for tumor staging were examined with respect to FDG accumulations in the acromio-clavicular (AC)-, gleno-humeral-, hip,, knee- and talo-tibial joints. FDG-uptake was graded using a semi-quantitative scale from 0 (no accumulation) to 4 (very strong accumulation comparable to brain uptake). Results: Joint activity of grade 1-2 was noted frequently, while grade 3 was rare, occurring only in the knee and shoulder joints, and grade 4 was inexistent. The 43 patients with grade 3 accumulations or with at least 4 joints showing grade 2 uptake were interviewed, but all denied pain specifically referred to a joint. Joint accumulations were seen in 50% of the acromio-clavicular-, 80% in the gleno-humeral-, 50% in the hip-, 90% in the knee and 80% in the talo-tibial joints. The intensities of joint accumulations correlated positively and significantly with patient age, ranging from r = 0.7 and p <0.05 in the knee to r = 0.96 and p <0.0001 in the AC joint. Conclusions: FDG accumulations in the joints in whole body FDG-PET scans are frequent and are very likely not related to symptoms. As there is a strong age correlation, and FDG is known to accumulate in inflammatory lesions, the findings are most likely a result of sub-clinical inflammatory synovial proliferation or other chronic inflammatory processes occurring in aging joints. (orig.)

  14. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  15. Early diagnosis and monitoring of whole-body accidental exposure

    International Nuclear Information System (INIS)

    Flury-Herard, A.; Jullien, D.

    1987-01-01

    This paper deals with the handling of accidental, acute or protracted, whole-body overexposures. It is complementary to the report DPS 86/07 SEAPS previously published. The criteria for initial classification, as a function of the mean absorbed dose, the clinical and paraclinical evaluation, the monitoring methods and the treatments to undertake are described successively. The basic components of the therapy are the intensive care of the hematological syndrome with blood products transfusions and anti-infection prophylaxy. The indications and conditions for bone-marrow grafts are also discussed [fr

  16. Start up of the whole body detection system

    International Nuclear Information System (INIS)

    Cortes P, A.; Angeles C, A.; Cuapio O, A.; Tejera R, A.

    1991-12-01

    The management of Radiological Safety of the Nuclear Center of Mexico has a whole body detection system Trade mark Canberra, manufactured by Bio-nuclear Measurements Inc. Ipswich Massachusetts. These systems are used to detect contamination of I-131 in thyroid and other nuclides (Cs-137, Cs-134, Co-60, etc.) in thorax. In this work the procedure that was continued for the setting in march of the thyroid detector is presented. A description of this system and an analysis of the uncertainties involved in the measures of activity of I-131 in thyroid of people occupationally exposed is made. (Author)

  17. The A.E.E. Winfrith Whole Body Monitor

    International Nuclear Information System (INIS)

    Peabody, C.O.; Fraser, V.M.; Speight, R.G.

    1962-10-01

    The function, design and construction of the A.E.E. Winfrith Whole Body Monitor are described. The main purpose of the monitor is to measure gamma emitting radioisotopes in the human body. Its performance, capabilities and limitations are discussed and a summary is given of experience gained and results obtained during the first few months of operation. The future programme of measurements and development is outlined. Some basic design criteria are put forward as a result of the experience and results obtained. (author)

  18. Physiological responses during whole body suspension of adult rats

    Science.gov (United States)

    Steffen, J. M.; Fell, R. D.; Musacchia, X. J.

    1987-01-01

    The objective of this study was to characterize responses of adult rats to one and two weeks of whole body suspension. Body weights and food and water intakes were initially reduced during suspension, but, while intake of food and water returned to presuspension levels, body weight remained depressed. Diuresis was evident, but only during week two. Hindlimb muscle responses were differential, with the soleus exhibiting the greatest atrophy and the EDL a relative hypertrophy. These findings suggest that adult rats respond qualitatively in a manner similar to juveniles during suspension.

  19. Effect of whole body irradiation on different tissues

    International Nuclear Information System (INIS)

    Casati, V.; Nardino, A.; Tomassi, I.; Becciolini, A.; Rizzi, M.; Martelli, T.

    1979-01-01

    The uptake and elimination of 14 C leucine were analysed in controls and in rats irradiated 2 h before injection with 8 Gy whole-body irradiation. Plasma, small intestine, kidney and skin were assayed after homogenization for TCA soluble and insoluble activity curves. In highly differentiated tissues with poor proliferative activity and low protein turnover, the uptake and elimination of the tracer did not appear to be affected by irradiation. In the small intestine differences between control and irradiated animals seemed significant. (Auth.)

  20. Whole-body vibration exercise in postmenopausal osteoporosis.

    Science.gov (United States)

    Weber-Rajek, Magdalena; Mieszkowski, Jan; Niespodziński, Bartłomiej; Ciechanowska, Katarzyna

    2015-03-01

    The report of the World Health Organization (WHO) of 2008 defines osteoporosis as a disease characterized by low bone mass and an increased risk of fracture. Postmenopausal osteoporosis is connected to the decrease in estrogens concentration as a result of malfunction of endocrine ovarian function. Low estrogens concentration causes increase in bone demineralization and results in osteoporosis. Physical activity, as a component of therapy of patients with osteoporosis, has been used for a long time now. One of the forms of safe physical activity is the vibration training. Training is to maintain a static position or execution of specific exercises involving the appropriate muscles on a vibrating platform, the mechanical vibrations are transmitted to the body of the patient. According to the piezoelectric theory, pressure induces bone formation in the electrical potential difference, which acts as a stimulant of the process of bone formation. Whole body vibration increases the level of growth hormone and testosterone in serum, preventing sarcopenia and osteoporosis. The aim of this study was to review the literature on vibration exercise in patients with postmenopausal osteoporosis based on the PubMed and Medline database. While searching the database, the following key words were used 'postmenopausal osteoporosis' and 'whole-body vibration exercise'.

  1. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  2. Safety aspects of whole-body cryochamber and cryosauna operation

    Science.gov (United States)

    Agnieszka, Piotrowska

    2017-12-01

    Interest in low temperature treatment is constantly increasing. Whole-body cryotherapy (WBC) devices are becoming available not only in medical centers but also in local gyms and spa centers. A new group of users are professional sport clubs where 3-minutes session of whole-body cryotherapy is post-training procedure to improve and speed up the recovery process. There are four different types of WBC devices available on the market and offered to commercial (non-medical) users. The American and European market is dominated by two of them: classic cryochambers and cryosaunas. Both constructions are supplied with liquid nitrogen. Low temperature inside classic cryochamber is produced by evaporating of liquid nitrogen in two or more heat exchangers. There is never a direct contact between user and cryogenic medium in any of system operation mode (closed supply system). Cryosauna is cooled down by filling with cold vapor of liquid nitrogen. Supply system is considered open because it allows for direct contact between user and cryogenic medium. Open supply system of cryosauna is primary and most questionable issue of its operational safety, particularly after tragic accident in October 2015. This paper presents the comparative analysis of classic cryochamber and cryosauna from safety point of view. Both devices have been analyzes and tested on existing systems in operation. Paper gives detailed analysis of constructions, supply systems and working parameters. Special attention has been focused to problem of oxygen deficiency hazard. Different failure or accident scenarios have been analyzed and discussed.

  3. Whole-body and multispectral photoacoustic imaging of adult zebrafish

    Science.gov (United States)

    Huang, Na; Xi, Lei

    2016-10-01

    Zebrafish is a top vertebrate model to study developmental biology and genetics, and it is becoming increasingly popular for studying human diseases due to its high genome similarity to that of humans and the optical transparency in embryonic stages. However, it becomes difficult for pure optical imaging techniques to volumetric visualize the internal organs and structures of wild-type zebrafish in juvenile and adult stages with excellent resolution and penetration depth. Even with the establishment of mutant lines which remain transparent over the life cycle, it is still a challenge for pure optical imaging modalities to image the whole body of adult zebrafish with micro-scale resolution. However, the method called photoacoustic imaging that combines all the advantages of the optical imaging and ultrasonic imaging provides a new way to image the whole body of the zebrafish. In this work, we developed a non-invasive photoacoustic imaging system with optimized near-infrared illumination and cylindrical scanning to image the zebrafish. The lateral and axial resolution yield to 80 μm and 600 μm, respectively. Multispectral strategy with wavelengths from 690 nm to 930 nm was employed to image various organs inside the zebrafish. From the reconstructed images, most major organs and structures inside the body can be precisely imaged. Quantitative and statistical analysis of absorption for organs under illumination with different wavelengths were carried out.

  4. Integrating cellular metabolism into a multiscale whole-body model.

    Directory of Open Access Journals (Sweden)

    Markus Krauss

    Full Text Available Cellular metabolism continuously processes an enormous range of external compounds into endogenous metabolites and is as such a key element in human physiology. The multifaceted physiological role of the metabolic network fulfilling the catalytic conversions can only be fully understood from a whole-body perspective where the causal interplay of the metabolic states of individual cells, the surrounding tissue and the whole organism are simultaneously considered. We here present an approach relying on dynamic flux balance analysis that allows the integration of metabolic networks at the cellular scale into standardized physiologically-based pharmacokinetic models at the whole-body level. To evaluate our approach we integrated a genome-scale network reconstruction of a human hepatocyte into the liver tissue of a physiologically-based pharmacokinetic model of a human adult. The resulting multiscale model was used to investigate hyperuricemia therapy, ammonia detoxification and paracetamol-induced toxication at a systems level. The specific models simultaneously integrate multiple layers of biological organization and offer mechanistic insights into pathology and medication. The approach presented may in future support a mechanistic understanding in diagnostics and drug development.

  5. Whole-body vibration exercise in postmenopausal osteoporosis

    Directory of Open Access Journals (Sweden)

    Magdalena Weber-Rajek

    2015-01-01

    Full Text Available The report of the World Health Organization (WHO of 2008 defines osteoporosis as a disease characterized by low bone mass and an increased risk of fracture. Postmenopausal osteoporosis is connected to the decrease in estrogens concentration as a result of malfunction of endocrine ovarian function. Low estrogens concentration causes increase in bone demineralization and results in osteoporosis. Physical activity, as a component of therapy of patients with osteoporosis, has been used for a long time now. One of the forms of safe physical activity is the vibration training. Training is to maintain a static position or execution of specific exercises involving the appropriate muscles on a vibrating platform, the mechanical vibrations are transmitted to the body of the patient. According to the piezoelectric theory, pressure induces bone formation in the electrical potential difference, which acts as a stimulant of the process of bone formation. Whole body vibration increases the level of growth hormone and testosterone in serum, preventing sarcopenia and osteoporosis. The aim of this study was to review the literature on vibration exercise in patients with postmenopausal osteoporosis based on the PubMed and Medline database. While searching the database, the following key words were used ‘postmenopausal osteoporosis’ and ‘whole-body vibration exercise’.

  6. Automatic anatomy recognition in whole-body PET/CT images

    International Nuclear Information System (INIS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-01

    , to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object

  7. Automatic anatomy recognition in whole-body PET/CT images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huiqian [College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China and Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Odhner, Dewey; Tong, Yubing; Torigian, Drew A. [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Zhao, Liming [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 and Research Center of Intelligent System and Robotics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China)

    2016-01-15

    , to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object.

  8. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  9. Comparison of atlas-based techniques for whole-body bone segmentation

    NARCIS (Netherlands)

    Arabi, Hossein; Zaidi, Habib

    We evaluate the accuracy of whole-body bone extraction from whole-body MR images using a number of atlas-based segmentation methods. The motivation behind this work is to find the most promising approach for the purpose of MRI-guided derivation of PET attenuation maps in whole-body PET/MRI. To this

  10. Biophysical study of mice blood after whole body irradiation

    Science.gov (United States)

    Saad El Din, Alsha A.; Desouky, Omar S.; El Behay, Amin Z.; El Sayed, Anwar A.

    1996-05-01

    The immediate of whole body fractionated doses of 137Cs gamma rays totalling 13 Gy on mice as well as the late effects of accumulative dose of 10 Gy (8 days after exposure) were studied. Changes due to gamma irradiation in hemoglobin conductivity and buffer capacity indicate the appearance of hydrophobic groups and changes in hydrophilic/hydrophobic ratio. These changes demonstrate different degrees of unfolding and refolding of the hemoglobin molecule. The viscosity coefficient of hemoglobin is found to increase at fractionated doses of 7 and 13 Gy. Such effect seems to be due to aggregation of the protein part of hemoglobin. The fractionated dose of 13 Gy causes changes in the electronic state of oxyhemoglobin indicated by an increase in methemoglobin which reduces biological activity.

  11. Whole body lymphangioscintigraphy in ferrets chronically infected with Brugia malayi

    Energy Technology Data Exchange (ETDEWEB)

    Witte, M.; McNeill, G.; Crandall, C.; Case, T.; Witte, C.; Crandall, R.; Hall, J.; Williams, W.

    1988-12-01

    Whole body lymphangioscintigraphy was performed after intradermal injection of /sup 99m/technetium human serum albumin or antimony colloid in the distal hindlimbs and forelimbs of ferrets chronically infected with Brugia malayi. The findings were compared with control ferrets and those with surgical interruption of the iliac lymphatics. While only one infected ferret manifested chronic hindlimb lymphedema, all exhibited delayed transport of radioisotope from the hindpaw with obstruction in the groin, poor or absent visualization of central lymphatic channels and regional lymph nodes, a picture similar to that following surgically induced lymphatic obstruction. In control ferrets, there was prompt visualization of peripheral lymphatic channels and regional lymph nodes with sharper and more extensive channel visualization after radiolabeled albumin and more intense sustained nodal visualization after radiolabeled antimony colloid. This noninvasive technique provides a readily repeatable investigative tool adaptable to small animals to study the evolution of lymphatic filariasis and other conditions associated with lymphatic obstruction.

  12. Particular aspects regarding the effects of whole body vibration exposure

    Directory of Open Access Journals (Sweden)

    Picu Mihaela

    2018-01-01

    Full Text Available This paper analyses the influence of whole-body vibrations on human performance; for this it was investigated how a group of men (20-29 years of age and a group of woman (21–31 years of age answered to specific requirements after being subjected to vertical vibrations under controlled laboratory conditions for 10-25 min. The vibrations were generated by a vibrant system with known amplitudes and frequencies. Accelerations were measured with NetdB - complex system for measuring and analysing human vibration and they were found in the range 0.4 - 3.1m/s2. The subjects’ performances were determined for each vibration level using specific tests. It can be concluded that exposure to vibrations higher than those recommended by ISO 2631 significantly disrupts how subjects responded to tests requirements.

  13. Computational Fluid Dynamics of Whole-Body Aircraft

    Science.gov (United States)

    Agarwal, Ramesh

    1999-01-01

    The current state of the art in computational aerodynamics for whole-body aircraft flowfield simulations is described. Recent advances in geometry modeling, surface and volume grid generation, and flow simulation algorithms have led to accurate flowfield predictions for increasingly complex and realistic configurations. As a result, computational aerodynamics has emerged as a crucial enabling technology for the design and development of flight vehicles. Examples illustrating the current capability for the prediction of transport and fighter aircraft flowfields are presented. Unfortunately, accurate modeling of turbulence remains a major difficulty in the analysis of viscosity-dominated flows. In the future, inverse design methods, multidisciplinary design optimization methods, artificial intelligence technology, and massively parallel computer technology will be incorporated into computational aerodynamics, opening up greater opportunities for improved product design at substantially reduced costs.

  14. Accuracy of whole-body plethysmography requires biological calibration

    DEFF Research Database (Denmark)

    Poorisrisak, Porntiva; Vrang, Carsten; Henriksen, Jorn Molgaard

    2009-01-01

    of accuracy. Our aim was to determine the agreement of sRaw measurements in six centers and expand normative sRaw values for nonasthmatic children including these centers. METHOD: Identical hardware with different software versions was used at the six centers. Measurements followed a standard operating......BACKGROUND: Specific airway resistance (sRaw) measured by whole-body plethysmography in young children is increasingly used in research and clinical practice. The method is precise and feasible. However, there is no available method for calibration of the resistance measure, which raises concern...... procedure: (1) seven healthy young children were brought to each of the six centers for sRaw measurements; and (2) 105 healthy preschool children (52 boys; mean age, 5.1 years; interquartile range, 4.3 to 6.0) were recruited locally for sRaw measurements. RESULTS: (1) The sRaw of the seven-children study...

  15. Whole-body cryotherapy: empirical evidence and theoretical perspectives

    Directory of Open Access Journals (Sweden)

    Bleakley CM

    2014-03-01

    Full Text Available Chris M Bleakley,1 François Bieuzen,2 Gareth W Davison,1 Joseph T Costello3 1Sport and Exercise Science Research Institute, Faculty of Life and Health Sciences, University of Ulster, Newtownabbey, Northern Ireland; 2Research Department, Laboratory of Sport, Expertise and Performance, French National Institute of Sport (INSEP, Paris, France; 3School of Exercise and Nutrition Sciences and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia Abstract: Whole-body cryotherapy (WBC involves short exposures to air temperatures below –100°C. WBC is increasingly accessible to athletes, and is purported to enhance recovery after exercise and facilitate rehabilitation postinjury. Our objective was to review the efficacy and effectiveness of WBC using empirical evidence from controlled trials. We found ten relevant reports; the majority were based on small numbers of active athletes aged less than 35 years. Although WBC produces a large temperature gradient for tissue cooling, the relatively poor thermal conductivity of air prevents significant subcutaneous and core body cooling. There is weak evidence from controlled studies that WBC enhances antioxidant capacity and parasympathetic reactivation, and alters inflammatory pathways relevant to sports recovery. A series of small randomized studies found WBC offers improvements in subjective recovery and muscle soreness following metabolic or mechanical overload, but little benefit towards functional recovery. There is evidence from one study only that WBC may assist rehabilitation for adhesive capsulitis of the shoulder. There were no adverse events associated with WBC; however, studies did not seem to undertake active surveillance of predefined adverse events. Until further research is available, athletes should remain cognizant that less expensive modes of cryotherapy, such as local ice-pack application or cold-water immersion, offer comparable

  16. Therapeutic effects of whole-body devices applying pulsed electromagnetic fields (PEMF): a systematic literature review.

    Science.gov (United States)

    Hug, Kerstin; Röösli, Martin

    2012-02-01

    Pulsed electromagnetic fields (PEMF) delivered by whole-body mats are promoted in many countries for a wide range of therapeutic applications and for enhanced well-being. However, neither the therapeutic efficacy nor the potential health hazards caused by these mats have been systematically evaluated. We conducted a systematic review of trials investigating the therapeutic effects of low-frequency PEMF devices. We were interested in all health outcomes addressed so far in randomized, sham-controlled, double-blind trials. In total, 11 trials were identified. They were focused on osteoarthritis of the knee (3 trials) or the cervical spine (1), fibromyalgia (1), pain perception (2), skin ulcer healing (1), multiple sclerosis-related fatigue (2), or heart rate variability and well-being (1). The sample sizes of the trials ranged from 12 to 71 individuals. The observation period lasted 12 weeks at maximum, and the applied magnetic flux densities ranged from 3.4 to 200 µT. In some trials sporadic positive effects on health were observed. However, independent confirmation of such singular findings was lacking. We conclude that the scientific evidence for therapeutic effects of whole-body PEMF devices is insufficient. Acute adverse effects have not been reported. However, adverse effects occurring after long-term application have not been studied so far. In summary, the therapeutic use of low-frequency whole-body PEMF devices cannot be recommended without more scientific evidence from high-quality, double-blind trials. Copyright © 2011 Wiley Periodicals, Inc.

  17. Whole-body diffusion-weighted imaging for staging malignant lymphoma in children

    Energy Technology Data Exchange (ETDEWEB)

    Kwee, Thomas C.; Takahara, Taro; Vermoolen, Malou A.; Mali, Willem P.; Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Bierings, Marc B. [University Medical Center Utrecht, Department of Pediatric Hematology, Utrecht (Netherlands)

    2010-10-15

    CT is currently the mainstay in staging malignant lymphoma in children, but the risk of second neoplasms due to ionizing radiation associated with CT is not negligible. Whole-body MRI techniques and whole-body diffusion-weighted imaging (DWI) in particular, may be a good radiation-free alternative to CT. DWI is characterized by high sensitivity for the detection of lesions and allows quantitative assessment of diffusion that may aid in the evaluation of malignant lymphomas. This article will review whole-body MRI techniques for staging malignant lymphoma with emphasis on whole-body DWI. Furthermore, future considerations and challenges in whole-body DWI will be discussed. (orig.)

  18. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  19. Whole-Body Vibration and Blood Flow and Muscle Oxygenation: A Meta-Analysis

    Science.gov (United States)

    Games, Kenneth E.; Sefton, JoEllen M.; Wilson, Alan E.

    2015-01-01

    Context: The use and popularity of whole-body vibration (WBV) has increased in recent years, but there is a lack of consensus in the literature about the effectiveness of the treatment. Objective: To quantitatively examine the effects of WBV on muscle oxygenation and peripheral blood flow in healthy adults. Data Sources: We searched Web of Science and PubMed databases and reference lists from relevant articles using the key terms whole body vibration, whole-body vibration, WBV, blood flow, peripheral blood flow, oxygenation, muscle oxygenation, circulation, circulatory, near infrared spectroscopy, NIRS, and power Doppler. Key terms were searched using single word and combination searches. No date range was specified. Study Selection: Criteria for inclusion were (1) use of a commercially available WBV device, (2) a human research model, (3) a pre-WBV condition and at least 1 WBV experimental condition, and (4) reporting of unstandardized means and standard deviations of muscle oxygenation or peripheral blood flow. Data Extraction: Means, standard deviations, and sample sizes were extracted from the text, tables, and figures of included studies. A total of 35 and 90 data points were extracted for the muscle-oxygenation and blood-flow meta-analyses, respectively. Data for each meta-analysis were combined and analyzed using meta-analysis software. Weighted, random-effects meta-analyses using the Hedges g metric were completed for muscle oxygenation and blood flow. We then conducted follow-up analyses using the moderator variables of vibration type, vibration time, vibration frequency, measurement location, and sample type. Data Synthesis: We found 18 potential articles. Further examination yielded 10 studies meeting the inclusion criteria. Whole-body vibration was shown to positively influence peripheral blood flow. Additionally, the moderators of vibration type and frequency altered the influence of WBV on blood flow. Overall, WBV did not alter muscle oxygenation

  20. Whole-body vibration and blood flow and muscle oxygenation: a meta-analysis.

    Science.gov (United States)

    Games, Kenneth E; Sefton, JoEllen M; Wilson, Alan E

    2015-05-01

    The use and popularity of whole-body vibration (WBV) has increased in recent years, but there is a lack of consensus in the literature about the effectiveness of the treatment. To quantitatively examine the effects of WBV on muscle oxygenation and peripheral blood flow in healthy adults. We searched Web of Science and PubMed databases and reference lists from relevant articles using the key terms whole body vibration, whole-body vibration, WBV, blood flow, peripheral blood flow, oxygenation, muscle oxygenation, circulation, circulatory, near infrared spectroscopy, NIRS, and power Doppler. Key terms were searched using single word and combination searches. No date range was specified. Criteria for inclusion were (1) use of a commercially available WBV device, (2) a human research model, (3) a pre-WBV condition and at least 1 WBV experimental condition, and (4) reporting of unstandardized means and standard deviations of muscle oxygenation or peripheral blood flow. Means, standard deviations, and sample sizes were extracted from the text, tables, and figures of included studies. A total of 35 and 90 data points were extracted for the muscle-oxygenation and blood-flow meta-analyses, respectively. Data for each meta-analysis were combined and analyzed using meta-analysis software. Weighted, random-effects meta-analyses using the Hedges g metric were completed for muscle oxygenation and blood flow. We then conducted follow-up analyses using the moderator variables of vibration type, vibration time, vibration frequency, measurement location, and sample type. We found 18 potential articles. Further examination yielded 10 studies meeting the inclusion criteria. Whole-body vibration was shown to positively influence peripheral blood flow. Additionally, the moderators of vibration type and frequency altered the influence of WBV on blood flow. Overall, WBV did not alter muscle oxygenation; however, when the measurement site was considered, muscle oxygenation increased or

  1. Whole Body Awareness for Controlling a Robotic Transfemoral Prosthesis.

    Science.gov (United States)

    Parri, Andrea; Martini, Elena; Geeroms, Joost; Flynn, Louis; Pasquini, Guido; Crea, Simona; Molino Lova, Raffaele; Lefeber, Dirk; Kamnik, Roman; Munih, Marko; Vitiello, Nicola

    2017-01-01

    Restoring locomotion functionality of transfemoral amputees is essential for early rehabilitation treatment and for preserving mobility and independence in daily life. Research in wearable robotics fostered the development of innovative active mechatronic lower-limb prostheses designed with the goal to reduce the cognitive and physical effort of lower-limb amputees in rehabilitation and daily life activities. To ensure benefits to the users, active mechatronic prostheses are expected to be aware of the user intention and properly interact in a closed human-in-the-loop paradigm. In the state of the art various cognitive interfaces have been proposed to online decode the user's intention. Electromyography in combination with mechanical sensing such as inertial or pressure sensors is a widely adopted solution for driving active mechatronic prostheses. In this framework, researchers also explored targeted muscles re-innervation for an objective-oriented surgical amputation promoting wider usability of active prostheses. However, information kept by the neural component of the cognitive interface deteriorates in a prolonged use scenario due to electrodes-related issues, thereby undermining the correct functionality of the active prosthesis. The objective of this work is to present a novel controller for an active transfemoral prosthesis based on whole body awareness relying on a wireless distributed non-invasive sensory apparatus acting as cognitive interface. A finite-state machine controller based on signals monitored from the wearable interface performs subject-independent intention detection of functional tasks such as ground level walking, stair ascent, and sit-to-stand maneuvres and their main sub-phases. Experimental activities carried out with four transfemoral amputees (among them one dysvascular) demonstrated high reliability of the controller capable of providing 100% accuracy rate in treadmill walking even for weak subjects and low walking speeds. The

  2. Whole Body Awareness for Controlling a Robotic Transfemoral Prosthesis

    Directory of Open Access Journals (Sweden)

    Andrea Parri

    2017-05-01

    Full Text Available Restoring locomotion functionality of transfemoral amputees is essential for early rehabilitation treatment and for preserving mobility and independence in daily life. Research in wearable robotics fostered the development of innovative active mechatronic lower-limb prostheses designed with the goal to reduce the cognitive and physical effort of lower-limb amputees in rehabilitation and daily life activities. To ensure benefits to the users, active mechatronic prostheses are expected to be aware of the user intention and properly interact in a closed human-in-the-loop paradigm. In the state of the art various cognitive interfaces have been proposed to online decode the user's intention. Electromyography in combination with mechanical sensing such as inertial or pressure sensors is a widely adopted solution for driving active mechatronic prostheses. In this framework, researchers also explored targeted muscles re-innervation for an objective-oriented surgical amputation promoting wider usability of active prostheses. However, information kept by the neural component of the cognitive interface deteriorates in a prolonged use scenario due to electrodes-related issues, thereby undermining the correct functionality of the active prosthesis. The objective of this work is to present a novel controller for an active transfemoral prosthesis based on whole body awareness relying on a wireless distributed non-invasive sensory apparatus acting as cognitive interface. A finite-state machine controller based on signals monitored from the wearable interface performs subject-independent intention detection of functional tasks such as ground level walking, stair ascent, and sit-to-stand maneuvres and their main sub-phases. Experimental activities carried out with four transfemoral amputees (among them one dysvascular demonstrated high reliability of the controller capable of providing 100% accuracy rate in treadmill walking even for weak subjects and low walking

  3. Sympathetic nerve activity and whole body heat stress in humans.

    Science.gov (United States)

    Low, David A; Keller, David M; Wingo, Jonathan E; Brothers, R Matthew; Crandall, Craig G

    2011-11-01

    We and others have shown that moderate passive whole body heating (i.e., increased internal temperature ∼0.7°C) increases muscle (MSNA) and skin sympathetic nerve activity (SSNA). It is unknown, however, if MSNA and/or SSNA continue to increase with more severe passive whole body heating or whether these responses plateau following moderate heating. The aim of this investigation was to test the hypothesis that MSNA and SSNA continue to increase from a moderate to a more severe heat stress. Thirteen subjects, dressed in a water-perfused suit, underwent at least one passive heat stress that increased internal temperature ∼1.3°C, while either MSNA (n = 8) or SSNA (n = 8) was continuously recorded. Heat stress significantly increased mean skin temperature (Δ∼5°C, P heat stress (Δ core temperature 0.63 ± 0.01°C) when expressed as burst frequency (26 ± 14 to 45 ± 16 bursts/min, P = 0.001), burst incidence (39 ± 13 to 48 ± 14 bursts/100 cardiac cyles, P = 0.03), or total activity (317 ± 170 to 489 ± 150 units/min, P = 0.02) and continued to increase until the end of heat stress (burst frequency: 61 ± 15 bursts/min, P = 0.01; burst incidence: 56 ± 11 bursts/100 cardiac cyles, P = 0.04; total activity: 648 ± 158 units/min, P = 0.01) relative to the mid-heating stage. Similarly, SSNA (total activity) increased midway through the heat stress (normothermia; 1,486 ± 472 to mid heat stress 6,467 ± 5,256 units/min, P = 0.03) and continued to increase until the end of heat stress (11,217 ± 6,684 units/min, P = 0.002 vs. mid-heat stress). These results indicate that both MSNA and SSNA continue to increase as internal temperature is elevated above previously reported values.

  4. Whole-body counting installation for assessment of internal contamination in workers

    International Nuclear Information System (INIS)

    Oliveira, C.A.N.; Cunha, P.G.; Lipsztein, J.L.; Bertelli, L.N.; Fonseca, A.M.G.; Ramalho, A.T.

    1985-01-01

    A whole-body counting installation for assessment of internal contamination in workers has recently been added to the Bioassay Division of the Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (IRD/CNEN). For the last two years the laboratory has been monitoring personnel involved in uranium mining and milling activities, monazite industry workers and nuclear medicine staff dealing with iodine-131 and technetium-99. Uptakes of radionuclides by the different organs and also dose equivalents are evaluated through the use of mathematical models. The IRD whole-body counter unit was specially designed to detect a variety of internally deposited radionuclides which emit photons in the energy range of 15 keV to 3 MeV. It consists of a monitoring room (2.5x2.5x2.5 m internal dimension), with 0.15 m thick steel walls, internally lined with 0.3 cm lead, 0.15 cm cadmium and 0.05 cm thick copper sheets. The facility is equipped with three different size NaI(T1) detectors and three 12.7 cm diameter phoswich detectors. (author)

  5. Whey Protein Supplementation Enhances Whole Body Protein Metabolism and Performance Recovery after Resistance Exercise: A Double-Blind Crossover Study.

    Science.gov (United States)

    West, Daniel W D; Abou Sawan, Sidney; Mazzulla, Michael; Williamson, Eric; Moore, Daniel R

    2017-07-11

    No study has concurrently measured changes in free-living whole body protein metabolism and exercise performance during recovery from an acute bout of resistance exercise. We aimed to determine if whey protein ingestion enhances whole body net protein balance and recovery of exercise performance during overnight (10 h) and 24 h recovery after whole body resistance exercise in trained men. In a double-blind crossover design, 12 trained men (76 ± 8 kg, 24 ± 4 years old, 14% ± 5% body fat; means ± standard deviation (SD)) performed resistance exercise in the evening prior to consuming either 25 g of whey protein (PRO; MuscleTech 100% Whey) or an energy-matched placebo (CHO) immediately post-exercise (0 h), and again the following morning (~10 h of recovery). A third randomized trial, completed by the same participants, involving no exercise and no supplement served as a rested control trial (Rest). Participants ingested [ 15 N]glycine to determine whole body protein kinetics and net protein balance over 10 and 24 h of recovery. Performance was assessed pre-exercise and at 0, 10, and 24 h of recovery using a battery of tests. Net protein balance tended to improve in PRO ( P = 0.064; effect size (ES) = 0.61, PRO vs. CHO) during overnight recovery. Over 24 h, net balance was enhanced in PRO ( P = 0.036) but not in CHO ( P = 0.84; ES = 0.69, PRO vs. CHO), which was mediated primarily by a reduction in protein breakdown (PRO protein supplementation improved MVC (ES = 0.76), REP (ES = 0.44), and peak power (ES = 0.55). In conclusion, whey protein supplementation enhances whole body anabolism, and may improve acute recovery of exercise performance after a strenuous bout of resistance exercise.

  6. Whole-body counting in the Marshall Islands

    International Nuclear Information System (INIS)

    Sun, L.C.; Clinton, J.; Kaplan, E.; Meinhold, C.B.

    1991-01-01

    In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish 137 Cesium body contents among the Enewetak, Rongelap and Utirik populations. 137 Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. 137 Cs body burdens tended to increase with age for both sexes, and were higher in males. The average 137 Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22±4 μSv. For Utirik, the dose was 33± 3 μSv. Since 1985 the Rongelap people have been self-exiled to Mejatto. Biological elimination should have reduced their dose to virtually zero, and the measured dose was 2±2 μSv. If they had remained on Rongelap Island, the calculated dose would have been 99 μSv, which is about one-third of the background dose. 7 refs., 1 tab

  7. Whole body thermal model of man during hyperthermia

    International Nuclear Information System (INIS)

    Charny, C.K.; Hagmann, M.J.; Levin, R.L.

    1987-01-01

    A whole body thermal model of man has been developed to predict the changes in regional temperatures and blood flows during hyperthermia treatments with the miniannular phased array (MAPA) and annular phased array (APA) applicators. A model of the thermoregulatory response to regional heating based on the experimental and numerical studies of others has been incorporated into this study. Experimentally obtained energy deposition patterns within a human leg exposed to the MAPA were input into the model and the results were compared to those based upon a theoretical deposition pattern. Exposure of the abdomen to the APA was modeled with and without the aberrant energy deposition that has been described previously. Results of the model reveal that therapeutic heating (>42 0 C) of extremity soft tissue sarcomas is possible without significant systemic heating. Very high bone temperatures (>50 0 C) were obtained when the experimental absorption pattern was used. Calculations show that systemic heating due to APA exposure is reduced via evaporative spray cooling techniques coupled with high-velocity ambient air flow

  8. Cryotherapy: local - whole-body; Kryotherapie Lokal - Ganzkoerper

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, R. [Klinik fuer Rheumatologie, St. Josef-Stift Sendenhorst (Germany)

    1994-12-31

    Cryotherapy, whether administered through ice, cold air, nitrogen or cold pack has an effect that can even reach the point of pain elimination. It also acts antiinflammatorily, eases swelling, and improves the function of inflamed joints. Further effects are alleviation of excess muscle tone and maintenance of blood irrigation in inflamed tissue. The fields of indication for cryotherapy can be summarised as follows: inflammation, pain, swelling, functional inhibition, excess muscle tone. Whole-body therapy at -110 C effects significantly enhanced function as compared with a control groups. Blood oxygen rises. Stenocarias have not been reported, whereas extrasystoles are said to decrease. Helper T lymphocytes in the circulating blood drop significantly in rheumatoid arthritis and Bechterev`s disease. This suggests autoimmune disease as a further field of indication. (orig.) [Deutsch] Kryotherapie mit Eis, Kaltluft, Stickstoff, Kaltluft oder Kaeltepackungen wirkt schmerzlindernd bis hin zu Schmerzaufhebung, wirkt entzuendungshemmend, abschwellend und bei Entzuendung funktionsverbessernd in betroffenen Gelenken, Muskeltonuserhoehungen werden abgebaut. Die Durchblutung, wird unter Ryotherapie im Entzuendungsbereich aufrechterhalten. Somit ergeben sich folgende Indikationen: Entzuendung, Schmerz, Schwellung, Funktionseinschraenkung, Muskeltonuserhoehung. Eine Ganzkoerperkaeltetherapie bei -110 C bewirkt eine signifikante Funktionsverbesserung gegenueber einer Kontrollgruppe. Die Sauerstoffkonzentration steigt im Blut. Stenokardien wurden nicht beobachtet. Extrasystolien nahmen ab. T-Helferlymphozyten sinken im zirkulierenden Blut bei Rheumatoider Arthritis und Morbus Bechterew signifikant ab. Daraus erbit sich als weitere Indikation die Behandlung von Autoimmunerkrankungen. (orig.)

  9. Cryotherapy: local - whole-body; Kryotherapie: Lokal - Ganzkoerper

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, R. [Klinik fuer Rheumatologie, St. Josef-Stift, Sendenhorst (Germany)

    1994-12-31

    Cryotherapy, whether administered through ice, cold air, nitrogen, or cold packs has an analgetic effect that can even reach the point of pain elimination. It also inhibits inflammation, relieves swelling, and improves the function of inflamed joints. Further effects are alleviation of excess muscle tone and maintenance of blood irrigation in inflamed tissue. The fields of indication for cryotherapy can be summarised as follows: inflammation, pain, swelling, functional inhibition, excess muscle tone. Whole-body therapy at -110 C effects significantly enhanced function as compared with a control group. Blood oxygen rises. Stenocardias have not been reported, whereas extrasystoles are said to decrease. Helper T lymphocytes in the circulating blood drop significantly in rheumatoid arthritis and Bechterev`s disease. This suggests autoimmune disease as a further field of indication. (orig.) [Deutsch] Kryotherapie mit Eis, Kaltluft, Stickstoff, Kaltluft oder Kaeltepackungen wirkt schmerzlindernd bis hin zur Schmerzaufhebung, wirkt entzuendungshemmend, abschwellend und bei Entzuendung funktionsverbessernd in betroffenen Gelenken. Muskeltonuserhoehungen werden abgebaut. Die Durchblutung wird unter Kryotherapie im Entzuendungsbereich aufrechterhalten. Somit ergeben sich folgende Indikationen: Entzuendung, Schmerz, Schwellung, Funktionseinschraenkung, Muskeltonuserhoehung. Eine Ganzkoerperkaeltetherapie bei -110 C bewirkt eine signifikante Funktionsverbesserung gegenueber einer Kontrollgruppe. Die Sauerstoffkonzentration steigt im Blut. Stenokardien wurden nicht beobachtet. Extrasystolien nahmen ab. T-Helferlymphozyten sinken im zirkulierenden Blut bei Rheumatoider Arthritis und Morbus Bechterew signifikant ab. Daraus ergibt sich als weitere Indikation die Behandlung von Autoimmunerkrankungen. (orig.)

  10. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  11. Intraocular lens dislocation after whole-body vibration.

    Science.gov (United States)

    Vela, José I; Andreu, David; Díaz-Cascajosa, Jesús; Buil, José A

    2010-10-01

    We present 2 cases of intraocular lens (IOL) dislocation that appeared shortly after the patients exercised on a vibration platform. The first patient was a 71-year-old woman who presented with lens subluxation in her right eye and a complete posterior IOL dislocation in her left eye. The second case was a 62-year-old woman who presented with unilateral IOL dislocation within the capsular bag in her right eye. Timing from IOL implantation to dislocation was approximately 6 years and 4 years, respectively. Pars plana vitrectomy with removal of the dislocated IOL was performed in both patients. Whole-body vibration training has become increasingly popular as a form of exercise training. It reportedly may provide benefits in physical function and in some diseases, especially in older people. However, evidence-based protocols ensuring safety and efficacy in this population are lacking. We discuss vibration as a cause of late IOL dislocation. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Utilization pattern of whole body computed tomography scanner

    International Nuclear Information System (INIS)

    Youn, Chul Ho; Lee, Sang Suk

    1986-01-01

    Computed tomography scanner (CT scanner) is one of the most expensive and sophisticated diagnostic tool and has already been utilized in many hospitals in Korea. The price as well as operating costs of CT scanner is so expensive as to regulate its installment by government even in the United States. In order to identify the efficient utilization of the CT scanner, the utilization pattern for CT scanning was analyzed at three general hospital in seoul. The results are as follows: 1. Five out of one thousand outpatients and five out of one hundred inpatients were CT scanned. 2. Eighty percent of patients who were scanned were those of inpatients of the hospitals where the scanned are installed. 3. Head standings constitute 45.6 percent of examinations, internal medicine 63.8 percent, and 38.5 percent neurosurgery respectively. 4. The rate of indication for CT scanning showed no statistically significant difference between insured and non-insured groups. 5. Computed tomography scanner units were operated 5.5 days a week in average and full operation rate was 79.5% in average. 6. The major diagnoses mode by head scanning were: hematoma (56.7%), infarction (12.6%), tumor (8.2%), and hydrocephalus (4.4%). 7. Number of patients taken CT Scanning was 43 persons a week in average for each whole body scanner unit

  13. Reconstruction of a whole-body counter into a process computer-controlled low-level whole-body scanner

    International Nuclear Information System (INIS)

    Hamann, C.

    1975-01-01

    A report is given on the state of the research project to reconstruct our whole-body counter with solid geometries into a scanning type one. The object is to develop a process computer controlled 'adaptive system'. The self-built scan mechanics are explained and the advantages and problems of applying stepping motors are gone into. A stepping motor coordinates control is presented. As the planned scanner and the process computer form a digital controlled system, all theoretical and actual values as well as the control orders from the process computer must be directly controllable. A CAMAC system was not used for economical reasons, the process periphery was made controllable by self building of interfaces to and from the computer. As example, the available multi-channel analyzers were converted to external controlling. The price-moderate and relatively simple self-built set-up are outlined and an example is given of how a TELETYPE version is reconstructed into a fast electronic interface. A BUS-MULTIPLEX system was developed which generates all necessary DI/DO interfaces out of one DI and DO address of the process computer only. The essential part of this system is given. (orig./LH) [de

  14. Accuracy of whole-body plethysmography requires biological calibration.

    Science.gov (United States)

    Poorisrisak, Porntiva; Vrang, Carsten; Henriksen, Jorn Molgaard; Klug, Bent; Hanel, Birgitte; Bisgaard, Hans

    2009-06-01

    Specific airway resistance (sRaw) measured by whole-body plethysmography in young children is increasingly used in research and clinical practice. The method is precise and feasible. However, there is no available method for calibration of the resistance measure, which raises concern of accuracy. Our aim was to determine the agreement of sRaw measurements in six centers and expand normative sRaw values for nonasthmatic children including these centers. Identical hardware with different software versions was used at the six centers. Measurements followed a standard operating procedure: (1) seven healthy young children were brought to each of the six centers for sRaw measurements; and (2) 105 healthy preschool children (52 boys; mean age, 5.1 years; interquartile range, 4.3 to 6.0) were recruited locally for sRaw measurements. (1) The sRaw of the seven-children study group was significantly lower at two centers compared with the other four centers, and one center had significantly higher sRaw than all the other centers (p factory settings of the software was subsequently discovered in one of the deviating centers. (2) Normative data (105 preschool children) were generated and were without significant difference between centers and independent of height, weight, age, and gender. We subsequently pooled these normative data (105 children) with our previous data from 121 healthy young children (overall mean sRaw, 1.27; SD, 0.25). Control using biological standards revealed errors in the factory setting and highlights the need for developing methods for verification of resistance measures to assure accuracy. Normative data were subsequently generated. Importantly, other centers using such normative data should first consider proper calibration before applying reference values.

  15. Automatic aortic root segmentation in CTA whole-body dataset

    Science.gov (United States)

    Gao, Xinpei; Kitslaar, Pieter H.; Scholte, Arthur J. H. A.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Reiber, Johan H. C.

    2016-03-01

    Trans-catheter aortic valve replacement (TAVR) is an evolving technique for patients with serious aortic stenosis disease. Typically, in this application a CTA data set is obtained of the patient's arterial system from the subclavian artery to the femoral arteries, to evaluate the quality of the vascular access route and analyze the aortic root to determine if and which prosthesis should be used. In this paper, we concentrate on the automated segmentation of the aortic root. The purpose of this study was to automatically segment the aortic root in computed tomography angiography (CTA) datasets to support TAVR procedures. The method in this study includes 4 major steps. First, the patient's cardiac CTA image was resampled to reduce the computation time. Next, the cardiac CTA image was segmented using an atlas-based approach. The most similar atlas was selected from a total of 8 atlases based on its image similarity to the input CTA image. Third, the aortic root segmentation from the previous step was transferred to the patient's whole-body CTA image by affine registration and refined in the fourth step using a deformable subdivision surface model fitting procedure based on image intensity. The pipeline was applied to 20 patients. The ground truth was created by an analyst who semi-automatically corrected the contours of the automatic method, where necessary. The average Dice similarity index between the segmentations of the automatic method and the ground truth was found to be 0.965±0.024. In conclusion, the current results are very promising.

  16. Inflammatory biomarkers responses after acute whole body vibration in fibromyalgia

    Directory of Open Access Journals (Sweden)

    V.G.C. Ribeiro

    2018-03-01

    Full Text Available The aims of this study were 1 to characterize the intensity of the vibration stimulation in women diagnosed with fibromyalgia (FM compared to a control group of healthy women (HW matched by age and anthropometric parameters, and 2 to investigate the effect of a single session of whole body vibration (WBV on inflammatory responses. Levels of adipokines, soluble tumor necrosis factor receptors (sTNFr1, sTNFr2, and brain-derived neurotrophic factor (BDNF were determined by enzyme-linked immunosorbent assay. Oxygen consumption (VO2 was estimated by a portable gas analysis system, heart rate (HR was measured using a HR monitor, and perceived exertion (RPE was evaluated using the Borg scale of perceived exertion. Acutely mild WBV increased VO2 and HR similarly in both groups. There was an interaction (disease vs vibration in RPE (P=0.0078, showing a higher RPE in FM compared to HW at rest, which further increased in FM after acute WBV, whereas it remained unchanged in HW. In addition, there was an interaction (disease vs vibration in plasma levels of adiponectin (P=0.0001, sTNFR1 (P=0.000001, sTNFR2 (P=0.0052, leptin (P=0.0007, resistin (P=0.0166, and BDNF (P=0.0179. In conclusion, a single acute session of mild and short WBV can improve the inflammatory status in patients with FM, reaching values close to those of matched HW at their basal status. The neuroendocrine mechanism seems to be an exercise-induced modulation towards greater adaptation to stress response in these patients.

  17. Whole body exposure of rats to sulfur mustard vapor.

    Science.gov (United States)

    Dachir, Shlomit; Rabinovitz, Ishai; Yaacov, Guy; Gutman, Hila; Cohen, Liat; Horwitz, Vered; Cohen, Maayan; Kadar, Tamar

    2017-11-24

    Sulfur mustard (SM) is an incapacitating chemical warfare agent used in numerous conflicts around the world and it is still a major threat for both, army troops and civilians. To evaluate its multiple targets effects in experimental setup, a model of whole body exposure (WBE) to SM vapor was established in rats and its simultaneous effects on lungs and eyes as well as on general wellbeing were examined. Rats were exposed to SM vapor. Evaluation (up to 10 weeks post-exposure) included body weight, general observation, blood counts and histological analysis. Results showed that following a latency-period of several hours, rats typical symptoms developed over a period of more than one week. The initial symptoms, characterized by swollen and erythematic nose, deteriorated into extensive rhinorrhea, eye closure, excessive lacrimation as well as rhonchi, wheezing and breathing difficulties. Alopecia and behavioral abnormality were also recorded. A weight loss of up to 40% was measured within one week with spontaneous recovery to baseline level within three weeks after exposure. Blood counts revealed leukopenia during the first three days post-exposure. Histological evaluation revealed a long lasting damage to the trachea, lungs and eyes. Thus, WBE to SM, was found to closely mimic the deleterious effects of SM on the sensitive tissues previously described in human victims during WWI and the Iran-Iraq war. The use of this animal model will enable comprehensive characterization of changes in biological processes that may lead to the development of therapeutic measures to ameliorate SM induced multi-system injuries.

  18. Contribution of anaerobic energy expenditure to whole body thermogenesis

    Directory of Open Access Journals (Sweden)

    Scott Christopher B

    2005-06-01

    Full Text Available Abstract Heat production serves as the standard measurement for the determination of energy expenditure and efficiency in animals. Estimations of metabolic heat production have traditionally focused on gas exchange (oxygen uptake and carbon dioxide production although direct heat measurements may include an anaerobic component particularly when carbohydrate is oxidized. Stoichiometric interpretations of the ratio of carbon dioxide production to oxygen uptake suggest that both anaerobic and aerobic heat production and, by inference, all energy expenditure – can be accounted for with a measurement of oxygen uptake as 21.1 kJ per liter of oxygen. This manuscript incorporates contemporary bioenergetic interpretations of anaerobic and aerobic ATP turnover to promote the independence of these disparate types of metabolic energy transfer: each has different reactants and products, uses dissimilar enzymes, involves different types of biochemical reactions, takes place in separate cellular compartments, exploits different types of gradients and ultimately each operates with distinct efficiency. The 21.1 kJ per liter of oxygen for carbohydrate oxidation includes a small anaerobic heat component as part of anaerobic energy transfer. Faster rates of ATP turnover that exceed mitochondrial respiration and that are supported by rapid glycolytic phosphorylation with lactate production result in heat production that is independent of oxygen uptake. Simultaneous direct and indirect calorimetry has revealed that this anaerobic heat does not disappear when lactate is later oxidized and so oxygen uptake does not adequately measure anaerobic efficiency or energy expenditure (as was suggested by the "oxygen debt" hypothesis. An estimate of anaerobic energy transfer supplements the measurement of oxygen uptake and may improve the interpretation of whole-body energy expenditure.

  19. Fire severity, size, and climate associations diverge from historical precedent along an ecological gradient in the Pinaleno Mountains, Arizona, USA

    Science.gov (United States)

    Christopher D. O' Connor; Donald A. Falk; Ann M. Lynch; Thomas W. Swetnam

    2014-01-01

    In recent decades fire size and severity have been increasing in high elevation forests of the American Southwest. Ecological outcomes of these increases are difficult to gauge without an historical context for the role of fire in these systems prior to interruption by Euro-American land uses. Across the gradient of forest types in the Pinaleño Mountains, a Sky Island...

  20. Comparison of the Effectiveness of Whole Body Vibration in Stroke Patients: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Yoo Jung Park

    2018-01-01

    Full Text Available Objectives. The goals of this study were to assess the effectiveness of WBV (whole body vibration training through an analysis of effect sizes, identify advantages of WBV training, and suggest other effective treatment methods. Methods. Four databases, namely, EMBASE, PubMed, EBSCO, and Web of Science, were used to collect articles on vibration. Keywords such as “vibration” and “stroke” were used in the search for published articles. Consequently, eleven studies were selected in the second screening using meta-analyses. Results. The total effect size of patients with dementia in the studies was 0.25, which was small. The effect size of spasticity was the greatest at 1.24 (high, followed by metabolism at 0.99 (high, balance, muscle strength, gait, and circulation in the decreasing order of effect size. Conclusions. The effect sizes for muscle strength and balance and gait function, all of which play an important role in performance of daily activities, were small. In contrast, effect sizes for bone metabolism and spasticity were moderate. This suggests that WBV training may provide a safe, alternative treatment method for improving the symptoms of stroke in patients.

  1. Comparison of the Effectiveness of Whole Body Vibration in Stroke Patients: A Meta-Analysis.

    Science.gov (United States)

    Park, Yoo Jung; Park, Sun Wook; Lee, Han Suk

    2018-01-01

    The goals of this study were to assess the effectiveness of WBV (whole body vibration) training through an analysis of effect sizes, identify advantages of WBV training, and suggest other effective treatment methods. Four databases, namely, EMBASE, PubMed, EBSCO, and Web of Science, were used to collect articles on vibration. Keywords such as "vibration" and "stroke" were used in the search for published articles. Consequently, eleven studies were selected in the second screening using meta-analyses. The total effect size of patients with dementia in the studies was 0.25, which was small. The effect size of spasticity was the greatest at 1.24 (high), followed by metabolism at 0.99 (high), balance, muscle strength, gait, and circulation in the decreasing order of effect size. The effect sizes for muscle strength and balance and gait function, all of which play an important role in performance of daily activities, were small. In contrast, effect sizes for bone metabolism and spasticity were moderate. This suggests that WBV training may provide a safe, alternative treatment method for improving the symptoms of stroke in patients.

  2. Whole-body vibration therapy in intensive care patients: A feasibility and safety study.

    Science.gov (United States)

    Boeselt, Tobias; Nell, Christoph; Kehr, Katahrina; Holland, Angélique; Dresel, Marc; Greulich, Timm; Tackenberg, Björn; Kenn, Klaus; Boeder, Johannes; Klapdor, Benjamin; Kirschbaum, Andreas; Vogelmeier, Claus; Alter, Peter; Koczulla, Andreas Rembert

    2016-03-01

    Admission to the intensive care unit is associated with sustained loss of muscle mass, reduced quality of life and increased mortality. Early rehabilitation measures may counteract this process. New approaches to rehabilitation while the patient remains in bed are whole-body vibration alone and whole-body vibration with a dumbbell. The aims of this study are to determine the safety of whole-body vibration for patients admitted to the intensive care unit, and to compare the effects of these techniques in intensive care unit patients and healthy subjects. Twelve intensive care unit patients and 12 healthy subjects using whole-body vibration for the first time were examined while lying in bed. First both groups performed whole body vibration over 3 min. In a second step whole body vibration with dumbbell was performed. In order to determine the safety of the training intensity, heart rate, oxygen saturation and blood pressure were measured. The study was approved by the Marburg ethics committee. There were minor reversible and transient increases in diastolic blood pressure (p = 0.005) and heart rate (p = 0.001) in the control group with whole-body vibration with a dumbbell. In intensive care patients receiving whole-body vibration alone, there were increases in diastolic blood pressure (p = 0.011) and heart rate (p vibration and whole-body vibration with a dumbbell for intensive care unit in-bed patients. No clinically significant safety problems were found. Whole-body vibration and whole-body vibration with a dumbbell might therefore be alternative methods for use in early in-bed rehabilitation, not only for hospitalized patients.

  3. Effects of Whole Body Vibration Training on Body Composition in Adolescents with Down Syndrome

    Science.gov (United States)

    Gonzalez-Aguero, Alejandro; Matute-Llorente, Angel; Gomez-Cabello, Alba; Casajus, Jose A.; Vicente-Rodriguez, German

    2013-01-01

    The present study aimed to determine the effect of 20 weeks of whole body vibration (WBV) on the body composition of adolescents with Down syndrome (DS). Thirty adolescent with DS were divided into two groups: control and WBV. Whole body, upper and lower limbs body fat and lean body mass were measured with dual energy X-ray absorptiometry (DXA)…

  4. Effect of a short period whole body vibration with 10 Hz on blood ...

    African Journals Online (AJOL)

    Effect of a short period whole body vibration with 10 Hz on blood biomarkers in Wistar rats. ... they might contribute to try to understand better these mechanisms that occur following exposure to a frequency of 10Hz. Keywords: whole-body vibration, biomarkers, Wistar rats, oscillating/vibratory platform, mechanical vibration ...

  5. Oak Ridge National Laboratory whole-body counter: internal operating procedure manual

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-08-01

    The general purpose of the ORNL Whole Body Counter is to provide a rapid estimation of the type and quantity of radionuclide deposited in the human body. This report contains a review of the equipment in use at the facility and the procedure for its operation, the standard procedure for performing a routine whole body count, and a discussion of interpretation of results

  6. Automated analysis and visualization of preclinical whole-body microCT data

    NARCIS (Netherlands)

    Baiker, Martin

    2011-01-01

    In this thesis, several strategies are presented that aim to facilitate the analysis and visualization of whole-body in vivo data of small animals. Based on the particular challenges for image processing, when dealing with whole-body follow-up data, we addressed several aspects in this thesis. The

  7. Made-to-measure pattern development based on 3D whole body scans

    NARCIS (Netherlands)

    Daanen, Hein; Hong, Sung Ae

    2008-01-01

    Purpose - New techniques are required to link 3D whole body scans to manufacturing techniques to allow for the mass-customization of clothes. This study aims to compare two methods of producing skirts based on 3D whole body scans. Design/methodology/approach - Three females participated in the

  8. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    NARCIS (Netherlands)

    A. Khmelinskii (Artem); H.C. Groen (Harald); M. Baiker (Martin); M. de Jong (Marion); B.P.F. Lelieveldt (Boudewijn)

    2012-01-01

    textabstractWhole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput,

  9. Segmentation and visual analysis of whole-body mouse skeleton microSPECT

    NARCIS (Netherlands)

    Khmelinskii, A.; Groen, H.C.; De Jong, M.; Lelieveldt, B.P.F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality,

  10. The influence of single whole body cryostimulation treatment on the dynamics and the level of maximal anaerobic power.

    Science.gov (United States)

    Klimek, Andrzej T; Lubkowska, Anna; Szyguła, Zbigniew; Frączek, Barbara; Chudecka, Monika

    2011-06-01

    The objective of this work was to determine the dynamics of maximal anaerobic power (MAP) of the lower limbs, following a single whole body cryostimulation treatment (WBC), in relation to the temperature of thigh muscles. The subjects included 15 men and 15 women with an average age (± SD) of 21.6 ± 1.2 years. To evaluate the level of anaerobic power, the Wingate test was applied. The subjects were submitted to 6 WBC treatments at -130°C once a day. After each session they performed a single Wingate test in the 15, 30, 45, 60, 75 and 90th min after leaving the cryogenic chamber. The order of the test was randomized. All Wingate tests were preceded by an evaluation of thigh surface temperature with the use of a thermovisual camera. The average thigh surface temperature (T(av)) in both men and women dropped significantly after the whole body cryostimulation treatment, and next increased gradually. In women T(av) remained decreased for 75 min, whereas in men it did not return to the basal level until 90th min. A statistically insignificant decrease in MAP was observed in women after WBC. On the contrary, a non-significant increase in MAP was observed in men. The course of changes in MAP following the treatment was similar in both sexes to the changes in thigh surface temperature, with the exception of the period between 15th and 30th min. The shorter time to obtain MAP was observed in women till 90th min and in men till 45 min after WBC compared to the initial level. A single whole body cryostimulation may have a minor influence on short-term physical performance of supramaximal intensity, but it leads to improvement of velocity during the start as evidenced by shorter time required to obtain MAP.

  11. A DXA Whole Body Composition Cross-Calibration Experience: Evaluation With Humans, Spine, and Whole Body Phantoms.

    Science.gov (United States)

    Krueger, Diane; Libber, Jessie; Sanfilippo, Jennifer; Yu, Hui Jing; Horvath, Blaine; Miller, Colin G; Binkley, Neil

    2016-01-01

    New densitometer installation requires cross-calibration for accurate longitudinal assessment. When replacing a unit with the same model, the International Society for Clinical Densitometry recommends cross-calibrating by scanning phantoms 10 times on each instrument and states that spine bone mineral density (BMD) should be within 1%, whereas total body lean, fat, and %fat mass should be within 2% of the prior instrument. However, there is limited validation that these recommendations provide adequate total body cross-calibration. Here, we report a total body cross-calibration experience with phantoms and humans. Cross-calibration between an existing and new Lunar iDXA was performed using 3 encapsulated spine phantoms (GE [GE Lunar, Madison, WI], BioClinica [BioClinica Inc, Princeton, NJ], and Hologic [Hologic Inc, Bedford, MA]), 1 total body composition phantom (BioClinica), and 30 human volunteers. Thirty scans of each phantom and a total body scan of human volunteers were obtained on each instrument. All spine phantom BMD means were similar (within 1%; phantom (BBCP) BMD and bone mineral content (BMC) values were within 2% with biases of 0.005 g/cm2 and -3.4 g. However, lean and fat mass and %fat differed by 4.6%-7.7% with biases of +463 g, -496 g, and -2.8%, respectively. In vivo comparison supported BBCP data; BMD and BMC were within ∼2%, but lean and fat mass and %fat differed from 1.6% to 4.9% with biases of +833 g, -860 g, and -1.1%. As all body composition comparisons exceeded the recommended 2%, the new densitometer was recalibrated. After recalibration, in vivo bias was lower (phantoms, despite good BMD and BMC agreement, did not detect substantial lean and fat differences observed using BBCP and in vivo assessments. Consequently, spine phantoms are inadequate for dual-energy X-ray absorptiometry whole body composition cross-calibration. Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights

  12. Egg and whole-body amino acid profile of African bonytongue (Heterotis niloticus) with an estimation of their dietary indispensable amino acids requirements.

    Science.gov (United States)

    Monentcham, Serge-Eric; Whatelet, Bernard; Pouomogne, Victor; Kestemont, Patrick

    2010-09-01

    African bonytongue, Heterotis niloticus, is a river fish from the Central and West Africa basin. The species presents a great potential for fish farming and has been increasingly raised in Central and South Cameroon. The total amino acid and proximate composition of the whole body of egg, larva, juvenile, immature, and adult Heterotis were determined. Ash, moisture, whole-body protein, and lipid contents were significantly affected by size (P amino acid composition of the whole-body tissue, when expressed as a percentage of dietary protein, was not significantly different among ontogenetic stages (ranging from 0.2 to 400 g mean body mass). The amino acid composition of the eggs was quite different to the one of whole-body tissue with lower levels of methionine, proline, and glycine, and higher levels of arginine, histidine, isoleucine, leucine, threonine, valine, serine, and alanine. The A/E ratios of adult Heterotis muscle tissue are similar to those obtained for other fish species, except for histidine and tryptophan. Based on whole-body or muscle tissue indispensable amino acids (IAA) to A/E ratios, the IAA requirement profiles for Heterotis (from larva to adult) were estimated and are similar to those of other omnivorous fish species, except for tryptophan and histidine.

  13. Systematic review: effect of whole-body computed tomography on mortality in trauma patients.

    Science.gov (United States)

    Hajibandeh, Shahab; Hajibandeh, Shahin

    2015-07-01

    The initial diagnostic evaluation and management of trauma patients is mainly based on Advanced Trauma Life Support (ATLS) guidelines worldwide. Based on ATLS principles, conventional diagnostics such as conventional radiography (CR) and focused abdominal sonography in trauma (FAST) should precede selective use of CT. Whole-body CT (WBCT) is highly accurate and allows detection of life threatening injuries with good sensitivity and specificity. WBCT is faster than conventional diagnostics and saves more time in management of trauma patients. This study aims to review studies investigating the effect of WBCT on mortality in trauma patients. Literatures were found by searching keywords in Medline, PubMed and Cochrane library. The relevant articles were selected by two independent reviewers based on title, abstract and introduction sections. Full-texts of selected articles were reviewed and those investigating effect of WBCT on mortality in trauma patients were included. Searching the keywords in Medline and PubMed resulted in 178 and 167 articles, respectively. Nine studies met the inclusion criteria and were reviewed. These included 8 retrospective and 1 prospective cohort studies. Mortality was measured as mortality rate or standardised mortality ratio (SMR) in the included studies. Unlike previous systematic reviews, this review indicates that use of WBCT in blunt trauma patients is associated with reduced overall mortality rate and that WBCT can potentially improve the probability of survival in haemodynamically stable and unstable blunt trauma patients. High quality RCTs are required to describe a causal relationship between WBCT and mortality in trauma patients. © 2015 KUMS, All rights reserved.

  14. Whole-body MRI for full assessment and characterization of diffuse inflammatory myopathy

    Directory of Open Access Journals (Sweden)

    Saleh Saleh Elessawy

    2016-09-01

    Full Text Available Background Conventional magnetic resonance imaging (MRI is a highly valuable tool for full assessment of the extent of bilateral symmetrical diffuse inflammatory myopathy, owing to its high sensitivity in the detection of edema which correlates with, and sometimes precedes, clinical findings. Purpose To evaluate the use of whole-body (WB-MRI in characterization and full assessment of the extent and distribution of diffuse inflammatory myopathy. Material and Methods A prospective study on 15 patients presenting with clinical evidence of inflammatory myopathy. It included 4 boys/men and 11 girls/women (age range, 6–44 years; mean age, 25.5 years. 1.5 T WB-MRI was performed and the distribution and extent of disease severity was assessed according to muscle edema on STIR images. Results Four cases of dermatomyositis showed lower limb disease predilection with edema in gluteal, thigh, and calf muscles. The same finding was seen in one case with recurrent polymyositis and three cases with overlap myositis with systemic lupus erythematosus (SLE. Bilateral upper and lower limb myositis was demonstrated in three cases of polymyositis and one case of overlap myositis with scleroderma. Bilateral edema involving all scanned muscle groups was detected in three cases of polymyositis with paraneoplastic syndrome, SLE, and severe active dermatomyositis (including the neck muscles. Conclusion WB-MRI is the diagnostic modality of choice for cases of inflammatory myopathy. It accurately detects the most severely affected muscles candidate for biopsy and provides a reliable baseline study for follow-up of disease progression as well as response to treatment.

  15. Conjugate whole-body scanning system for quantitative measurement of organ distribution in vivo

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Chen, C.T.; Yasillo, N.J.; Ortega, C.J.; Charleston, D.B.; Lathrop, K.A.

    1979-01-01

    The determination of accurate, quantitative, biokinetic distribution of an internally dispersed radionuclide in humans is important in making realistic radiation absorbed dose estimates, studying biochemical transformations in health and disease, and developing clinical procedures indicative of abnormal functions. In order to collect these data, a whole-body imaging system is required which provides both adequate spatial resolution and some means of absolute quantitation. Based on these considerations, a new whole-body scanning system has been designed and constructed that employs the conjugate counting technique. The conjugate whole-body scanning system provides an efficient and accurate means of collecting absolute quantitative organ distribution data of radioactivity in vivo

  16. Whey Protein Supplementation Enhances Whole Body Protein Metabolism and Performance Recovery after Resistance Exercise: A Double-Blind Crossover Study

    Directory of Open Access Journals (Sweden)

    Daniel W. D. West

    2017-07-01

    Full Text Available No study has concurrently measured changes in free-living whole body protein metabolism and exercise performance during recovery from an acute bout of resistance exercise. We aimed to determine if whey protein ingestion enhances whole body net protein balance and recovery of exercise performance during overnight (10 h and 24 h recovery after whole body resistance exercise in trained men. In a double-blind crossover design, 12 trained men (76 ± 8 kg, 24 ± 4 years old, 14% ± 5% body fat; means ± standard deviation (SD performed resistance exercise in the evening prior to consuming either 25 g of whey protein (PRO; MuscleTech 100% Whey or an energy-matched placebo (CHO immediately post-exercise (0 h, and again the following morning (~10 h of recovery. A third randomized trial, completed by the same participants, involving no exercise and no supplement served as a rested control trial (Rest. Participants ingested [15N]glycine to determine whole body protein kinetics and net protein balance over 10 and 24 h of recovery. Performance was assessed pre-exercise and at 0, 10, and 24 h of recovery using a battery of tests. Net protein balance tended to improve in PRO (P = 0.064; effect size (ES = 0.61, PRO vs. CHO during overnight recovery. Over 24 h, net balance was enhanced in PRO (P = 0.036 but not in CHO (P = 0.84; ES = 0.69, PRO vs. CHO, which was mediated primarily by a reduction in protein breakdown (PRO < CHO; P < 0.01. Exercise decreased repetitions to failure (REP, maximal strength (MVC, peak and mean power, and countermovement jump performance (CMJ at 0 h (all P < 0.05 vs. Pre. At 10 h, there were small-to-moderate effects for enhanced recovery of the MVC (ES = 0.56, mean power (ES = 0.49, and CMJ variables (ES: 0.27–0.49 in PRO. At 24 h, protein supplementation improved MVC (ES = 0.76, REP (ES = 0.44, and peak power (ES = 0.55. In conclusion, whey protein supplementation enhances whole body anabolism, and may improve acute recovery of

  17. Whole-Body MRI versus PET in assessment of multiple myeloma disease activity.

    LENUS (Irish Health Repository)

    Shortt, Conor P

    2009-04-01

    The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma.

  18. Various performance-enhancing effects from the same intensity of whole-body vibration training

    Directory of Open Access Journals (Sweden)

    Paohung Chung

    2017-09-01

    Conclusion: All frequency and amplitude settings in the 8-week whole-body vibration training increased muscle strength, but different settings resulted in various neuromuscular adaptations despite the same intensity.

  19. Signal Processing Methods for Removing the Effects of Whole Body Vibration upon Speech

    Science.gov (United States)

    Bitner, Rachel M.; Begault, Durand R.

    2014-01-01

    Humans may be exposed to whole-body vibration in environments where clear speech communications are crucial, particularly during the launch phases of space flight and in high-performance aircraft. Prior research has shown that high levels of vibration cause a decrease in speech intelligibility. However, the effects of whole-body vibration upon speech are not well understood, and no attempt has been made to restore speech distorted by whole-body vibration. In this paper, a model for speech under whole-body vibration is proposed and a method to remove its effect is described. The method described reduces the perceptual effects of vibration, yields higher ASR accuracy scores, and may significantly improve intelligibility. Possible applications include incorporation within communication systems to improve radio-communication systems in environments such a spaceflight, aviation, or off-road vehicle operations.

  20. Modulation of the gut microbiota with antibiotic treatment suppresses whole body urea production in neonatal pigs

    DEFF Research Database (Denmark)

    Puiman, Patrycja; Stoll, Barbara; Mølbak, Lars

    2013-01-01

    administered antibiotics, or probiotics affects whole body nitrogen and amino acid turnover. We quantified whole body urea kinetics, threonine fluxes, and threonine disposal into protein, oxidation, and tissue protein synthesis with stable isotope techniques. Compared with controls, antibiotics reduced...... decreased protein synthesis rate in the proximal SI and liver but did not affect the distal SI, colon, or muscle. Probiotics induced a bifidogenic microbiota and decreased plasma urea concentrations but did not affect whole body threonine or protein metabolism. Probiotics decreased protein synthesis...... in the proximal SI but not in other tissues. In conclusion, modulation of the gut microbiota by antibiotics and probiotics reduced hepatic ureagenesis and intestinal protein synthesis, but neither altered whole body net threonine balance. These findings suggest that changes in amino acid and nitrogen metabolism...

  1. Whole-body detector calibrating with a modular phantom

    International Nuclear Information System (INIS)

    Minev, L.; Boshkova, T.; Uzunov, P.

    1995-01-01

    Human body models (phantoms) of various size and weight are produced in order to calibrate gamma spectrometers for accurate activity measurement. The phantoms are built of separate modules with mass of 0.5 kg and size 20 x 14 x 2 cm. There are modules with standard Eu-152 and Am-241 radioactivity designed for homogenous radioactivity imitating and critical organs moulding, as well as 'zero' -phantom modules without activity imitating a standard human body. Human organs are modelled by 11 x 9 x 0.5 cm modules with 0.16 kg mass. The phantoms have been used to obtain calibration curves and absolute efficiencies for selected energies of radionuclides expected to be found in the Kozloduy NPP staff. It is shown that the efficiency depends not only on the mass but on the geometric size of the measured object. Scanning of phantoms has been carried out and a profile of activity obtained. The profile consists of an abrupt rising of the sum of pulses (measuring time - 20 s) when the detector passes from neck to chest, a plateau when it moves over the head or the trunk and gradual decrease over the legs. Profiles of activity in organs are best obtained with a lead collimator. 4 refs., 7 figs., 2 tabs

  2. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  3. Effect of meal and propranolol on whole body and splanchnic oxygen consumption in patients with cirrhosis

    DEFF Research Database (Denmark)

    Krag, Aleksander; Simonsen, Lene; Henriksen, Jens H

    2006-01-01

    Our aim was to measure whole body energy expenditure after a mixed liquid meal, with and without simultaneous propranolol infusion, in patients with cirrhosis. We also wanted to investigate the effect of propranolol on substrate fluxes and oxygen uptake in the tissues drained by the hepatic vein ...... as splanchnic oxygen uptake. The splanchnic reduction in oxygen consumption can explain almost the entire reduction in whole body oxygen consumption....

  4. Detection of multifocal osteonecrosis in an adolescent with dermatomyositis using whole-body MRI

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Tania C.M.; Terreri, Maria Teresa A.; Hilario, Maria Odete E. [Federal University of Sao Paulo, Department of Pediatrics, Division of Allergy, Clinical Immunology and Rheumatology, Sao Paulo, SP (Brazil); Lederman, Henrique [Federal University of Sao Paulo, Image Diagnosis Department, Sao Paulo (Brazil); Kaste, Sue C. [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Division of Diagnostic Imaging, Memphis, TN (United States)

    2010-09-15

    Osteonecrosis is a well-recognized complication of corticosteroid use resulting in significant morbidity, often requiring surgical intervention. Whole-body MRI is a promising method that allows imaging of the whole patient in a reasonable time without the use of ionizing radiation. This technique has the potential for evaluating nonmalignant multifocal skeletal disease like osteonecrosis. This case highlights the value of whole-body MR in an adolescent with dermatomyositis who developed multifocal osteonecrosis. (orig.)

  5. Experience with a mobile whole body counting screening program at Ontario Hydro

    International Nuclear Information System (INIS)

    Wong, K.Y.

    1976-01-01

    A whole-body counting program using a trailer-mounted counter has been in service in Ontario Hydro since 1972 to monitor routinely internal uptakes of radionuclides by nuclear station employees. The philosophy and objectives of the program are discussed; equipment and calibration procedures are described, and experience over the past two and a half years is reviewed. The procedures to minimize the effects of external contamination, a problem commonly encountered in whole-body counting, are described. (auth)

  6. Whole-body MRI using a sliding table and repositioning surface coil approach

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, Thomas; Luijten, Peter; Kibune, Satoshi; Ochiai, Reiji; Sakamoto, Tetsuro; Niwa, Tetsu; Van Cauteren, Marc

    2010-01-01

    To introduce and assess a new way of performing whole-body magnetic resonance imaging (MRI) using a non-integrated surface coil approach as available on most clinical MRI systems worldwide. Ten consecutive asymptomatic subjects prospectively underwent whole-body MRI for health screening. Whole-body MRI included T1-, T2- and diffusion-weighted sequences, and was performed using a non-integrated surface coil to image four different stations without patient repositioning. The four separately acquired stations were merged, creating seamless coronal whole-body T1-, T2- and diffusion-weighted images. Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations were qualitatively assessed. The average time (±SD) taken to change the surface coil from one station to the next station was 53.8 (±7.1) s. The average total extra examination time ± SD was 2 min 41.4 s (±15.3 s). Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations of T1-, T2- and diffusion-weighted whole-body MRI were overall graded as ''good'' to ''excellent''. This study shows that a time-efficient and high-quality whole-body MRI examination can easily be performed by using a non-integrated sliding surface coil approach. (orig.)

  7. [Low back pain among farmers exposed to whole body vibration: a literature review].

    Science.gov (United States)

    Solecki, Leszek

    2011-01-01

    A literature review was performed for the years 1990-2007. It covered reports addressing the problems associated with the prevalence of low back pain and musculoskeletal disorders among farmers. In addition, the anticipated relationship between low back pain and whole body vibration in farmers was evaluated based on 12 reports for the years 1987-2009. The review confirmed that the prevalence of back pain is significantly higher in farmers exposed to whole body vibration than in the control group (not exposed to vibration). The frequency of back pain is related with whole body vibration, as well as with prolonged sitting position, wrong body posture and physical work load (especially lifting and carrying loads). The prevalence of these symptoms increases with the increased vibration dose and duration of exposure. Disorders in the lower section of the spine were associated with age, accidents (concerning the back), cumulative dose of whole body vibration, and overload due to wrong body posture. Long-term exposure affecting the whole body is harmful to the skeletal system (degeneration of the spine). The results of the study suggest that the repeated or constant exposure to mechanical shocks may increase the risk of low back pain. The investigations confirmed that there is a dose-response type of relationship between exposure to whole body vibration and pain in the lumbar section of the spine.

  8. Fragmentation of chromatin DNA in mouse thymus cells after whole body γ-irradiation

    International Nuclear Information System (INIS)

    Wei Kang; Liu Xueying; Zhu Xuefen

    1984-01-01

    The characteristics of soluble chromatin in mouse thymus nuclei after whole body γ-irradiation were investigated by means of polyacrylamide gel electrophoresis. After deproteinization and electrophoresis eight regular DNA bands were revealed. The molecular weights of these bands were estimated by comparing their migration rates with those of the standard fragments obtained from PBR 322 digested completely by restrictive endonuclease Hae III. The molecular weight of the first band was calculated to be 186 base pairs corresponding approximately to the size of DNA fragment from a single nucleosome, and those of other bands appeared to be its multiples. The results suggested that the disintegration of chromatin DNA after γ-irradiation might have occurred at the linkage regions of chromatin. The autolysis product of normal thymus chromatin under sterile condition were also analyzed and its electrophoretic pattern was found to be just the same as that of the postirradiation product. It seems, therefore, that the endonuclease existing in normal tissues might be responsible for the postirradiation chromatin degradation. The mechanism of this kind of enzymatic digestion remains to be elucidated in further investigation. (author)

  9. Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses

    International Nuclear Information System (INIS)

    Koukorava, C; Farah, J; Clairand, I; Donadille, L; Struelens, L; Vanhavere, F; Dimitriou, P

    2014-01-01

    Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that ‘wrap around’ glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceiling-suspended screens were more efficient when positioned close to the patient’s skin and to the x-ray field. With the use of such shields, the H p (10) values recorded at the collar, chest and waist level and the H p (3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses. (paper)

  10. Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses.

    Science.gov (United States)

    Koukorava, C; Farah, J; Struelens, L; Clairand, I; Donadille, L; Vanhavere, F; Dimitriou, P

    2014-09-01

    Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that 'wrap around' glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceiling-suspended screens were more efficient when positioned close to the patient's skin and to the x-ray field. With the use of such shields, the Hp(10) values recorded at the collar, chest and waist level and the Hp(3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses.

  11. Whole Body Magnetic Resonance Imaging in the Diagnosis of Parsonage Turner Syndrome

    International Nuclear Information System (INIS)

    Ryan, M.; Twair, A.; Nelson, E.; Brennan, D.; Eustace, S.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings in patients with suspected Parsonage Turner syndrome and to emphasize the value of an additional whole body MR scan to improve specificity of this diagnosis. Material and Methods: Three patients with proven Parsonage Turner syndrome referred for conventional MRI of the shoulder girdle and additional whole body turboSTIR MRI were included for study. Results: In each case, imaging revealed edema in the muscles of the shoulder girdle. Whole body turboSTIR MRI scan confirmed localized unilateral changes in each case improving specificity and confidence in the diagnosis of Parsonage Turner syndrome in each case. Conclusion: Whole body turboSTIR MR imaging is a useful diagnostic tool in the evaluation of patients with suspected Parsonage Turner syndrome. Inclusion of the brain, neck, brachial plexus, and extremity musculature at whole body imaging allows differentiation from polymyositis and elimination of additional causes of shoulder girdle pain and weakness including gross lesions in the brain, neck, and brachial plexus by a single non-invasive study

  12. Benefits of whole body vibration training in patients hospitalised for COPD exacerbations - a randomized clinical trial.

    Science.gov (United States)

    Greulich, Timm; Nell, Christoph; Koepke, Janine; Fechtel, Juliane; Franke, Maja; Schmeck, Bernd; Haid, Daniel; Apelt, Sandra; Filipovic, Silke; Kenn, Klaus; Janciauskiene, Sabina; Vogelmeier, Claus; Koczulla, Andreas Rembert

    2014-04-11

    Patients with stable COPD show improvements in exercise capacity and muscular function after the application of whole body vibration. We aimed to evaluate whether this modality added to conventional physiotherapy in exacerbated hospitalised COPD patients would be safe and would improve exercise capacity and quality of life. 49 hospitalised exacerbated COPD patients were randomized (1:1) to undergo physiotherapy alone or physiotherapy with the addition of whole body vibration. The primary endpoint was the between-group difference of the 6-minute walking test (day of discharge - day of admission). Secondary assessments included chair rising test, quality of life, and serum marker analysis. Whole body vibration did not cause procedure-related adverse events. Compared to physiotherapy alone, it led to significantly stronger improvements in 6-minute walking test (95.55 ± 76.29 m vs. 6.13 ± 81.65 m; p = 0.007) and St. Georges Respiratory Questionnaire (-6.43 ± 14.25 vs. 5.59 ± 19.15, p = 0.049). Whole body vibration increased the expression of the transcription factor peroxisome proliferator receptor gamma coactivator-1-α and serum levels of irisin, while it decreased serum interleukin-8. Whole body vibration during hospitalised exacerbations did not cause procedure-related adverse events and induced clinically significant benefits regarding exercise capacity and health-related quality of life that were associated with increased serum levels of irisin, a marker of muscle activity. German Clinical Trials Register DRKS00005979. Registered 17 March 2014.

  13. Whole-body MR neurography: Prospective feasibility study in polyneuropathy and Charcot-Marie-Tooth disease.

    Science.gov (United States)

    Chhabra, Avneesh; Carrino, John A; Farahani, Sahar J; Thawait, Gaurav K; Sumner, Charlotte J; Wadhwa, Vibhor; Chaudhary, Vinay; Lloyd, Thomas E

    2016-12-01

    To evaluate the feasibility of whole-body magnetic resonance neurography (WBMRN) in polyneuropathy for technical feasibility, distribution of nerve abnormalities, and differentiation. Twenty WBMRN examinations were performed on a 3T scanner over 2 years. Patient demographics including history of hereditary and acquired neuropathy were recorded. The images were evaluated by two independent readers with nerve imaging experience for quality. The nerve signal and size alterations were measured in the brachial plexus, lumbosacral plexus, and femoral and sciatic nerves; diffusion tensor imaging parameters (fractional anisotropy [FA] and apparent diffusion coefficient [ADC]) were determined in plexuses, and tractography was performed. Nonparametric Wilcoxon rank sum test, receiver operating characteristic (ROC) analysis, and intraclass correlation coefficients (ICCs) were obtained. Excellent image quality was obtained for the majority of lumbosacral (LS) plexus (18/20) and 50% of brachial plexus (10/20) regions. Qualitatively among cases, the nerve hyperintensity and/or thickening involved the brachial plexus (11/11), LS plexus (7/11), and both plexuses (7/11), with most nerve thickenings observed in Charcot-Marie-Tooth disease type 1. The nerve signal intensity alterations were significantly different for both brachial (P < 0.05) and LS (P < 0.05) plexuses in cases versus controls. The femoral and sciatic nerve size alterations were different (P < 0.05), while signal intensity differences were not significant (P = 0.1-0.97). Transverse dimensions of C8 (4 mm), L5 (6.2 mm) and S1 (5.1 mm) nerve roots, and sciatic nerves (10.2 mm) were the most accurate diagnostic performance measures in distinguishing cases from controls. WBMRN is feasible for use in the clinical practice for the identification and potential characterization of polyneuropathy. J. Magn. Reson. Imaging 2016;44:1513-1521. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

    Science.gov (United States)

    Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva

    2017-06-01

    The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.

  15. Analysis of whole-body vibration on rheological models for tissues

    Science.gov (United States)

    Neamţu, A.; Simoiu, D.; Nyaguly, E.; Crastiu, I.; Bereteu, L.

    2018-01-01

    Whole body vibrations have become a very popular method in recent years, both in physical therapy and in sports. This popularity is due to the fact that, as a result of analyzing the groups of subjects, the effects of small amplitude vibration and low frequency vibration, it was found an increase in the force developed by the feet, a hardening of bone strength or an increase in bone density. In this paper we propose to give a possible explanation of the stress relieving in muscle and/or bone after whole body vibration treatment. To do this we consider some rheological models which after whole body vibrations and after the analysis of their response lead to various experiments.

  16. A non-rigid registration method for mouse whole body skeleton registration

    Science.gov (United States)

    Xiao, Di; Zahra, David; Bourgeat, Pierrick; Berghofer, Paula; Acosta Tamayo, Oscar; Wimberley, Catriona; Gregoire, Marie Claude; Salvado, Olivier

    2010-03-01

    Micro-CT/PET imaging scanner provides a powerful tool to study tumor in small rodents in response to therapy. Accurate image registration is a necessary step to quantify the characteristics of images acquired in longitudinal studies. Small animal registration is challenging because of the very deformable body of the animal often resulting in different postures despite physical restraints. In this paper, we propose a non-rigid registration approach for the automatic registration of mouse whole body skeletons, which is based on our improved 3D shape context non-rigid registration method. The whole body skeleton registration approach has been tested on 21 pairs of mouse CT images with variations of individuals and time-instances. The experimental results demonstrated the stability and accuracy of the proposed method for automatic mouse whole body skeleton registration.

  17. Disseminated cysticercosis in a child: whole-body MR diagnosis with the use of parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Atin; Goenka, Ajit Harishkumar [All India Institute of Medical Sciences, Department of Radiology, New Delhi, Delhi (India); Choudhary, Anita; Sahu, Jitendra Kumar; Gulati, Sheffali [All India Institute of Medical Sciences, Department of Paediatrics, New Delhi, Delhi (India)

    2010-02-15

    Cysticercosis is a parasitic disease caused by infestation with the encysted larval stage of the pork tapeworm, Taenia solium. Disseminated cysticercosis is an exceptional expression of this disease characterized by high morbidity due to massive symptomatic parasite burden in the central nervous system, striated muscles, subcutaneous tissues and other organs. Less than 50 such cases have been reported worldwide, and fewer than 10 children. We report on the whole-body MR diagnosis of extensively disseminated cysticercosis in a child. The critical role of whole-body MR as a stand-alone modality in the diagnosis and management of this pleomorphic disease is highlighted. Whole-body MR diagnosis of an infectious disease is unique. (orig.)

  18. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro

    1991-01-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs

  19. Morphological studies on the healing process of tooth extraction wounds in whole body irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Yoichiro (Hokkaido Univ., Sapporo (Japan). School of Dentistry)

    1991-06-01

    The present studies were performed to investigate the healing process of the tooth extraction wound in whole body irradiated rats and to clarify the effect of irradiation on bone metabolism. One hundred and seven Wistar rats of about 100 g body weight were used and divided into 3 groups. Whole body irradiated rats were given single exposure with a dose of 8 Gy. The region of the left upper molars of local irradiated rats as controls, was exposed to 8 Gy. On the 7th day after irradiation, the left upper first molar of each rat was extracted. The rats were sacrificed at intervals of 1 to 14 days after extraction. Non-irradiated rats were sacrificed at the same intervals after extraction. The maxillary bone including the extraction wound was evaluated, histologically, histometrically and ultrastructurally. From the histological and histometrical findings, the difference of the healing process between non-irradiated rats and locally irradiated rats is not significant. In whole body irradiated rats, the healing process especially in the socket was disturbed. The osteoblastic new bone formation following production of granulation tissue was interfered with. Ultrastructurally, the cytoplasmic organellae were poorly developed in the osteoblast and osteoid formation was reduced in the socket. But periosteal new bone formation was the same as that of the locally irradiated rats. In whole body irradiated rats, the osteoclasts in the interradicular alveolar bone were decreased and have smaller nuclei, compared with non-irradiated and locally irradiated rats. Histometrically, the amount of bone loss was decreased in whole body irradiated rats. Ultrastructurally, the cyoplasmic organellae and ruffled border were poorly developed in the osteoclasts of whole body irradiated rats. The findings suggested that irradiation induced cytological changes not only in osteoblasts but in osteoclasts and these changes resulted in the delayed healing of extraction wound. (author) 106 refs.

  20. Comparison of image enhancement methods for the effective diagnosis in successive whole-body bone scans.

    Science.gov (United States)

    Jeong, Chang Bu; Kim, Kwang Gi; Kim, Tae Sung; Kim, Seok Ki

    2011-06-01

    Whole-body bone scan is one of the most frequent diagnostic procedures in nuclear medicine. Especially, it plays a significant role in important procedures such as the diagnosis of osseous metastasis and evaluation of osseous tumor response to chemotherapy and radiation therapy. It can also be used to monitor the possibility of any recurrence of the tumor. However, it is a very time-consuming effort for radiologists to quantify subtle interval changes between successive whole-body bone scans because of many variations such as intensity, geometry, and morphology. In this paper, we present the most effective method of image enhancement based on histograms, which may assist radiologists in interpreting successive whole-body bone scans effectively. Forty-eight successive whole-body bone scans from 10 patients were obtained and evaluated using six methods of image enhancement based on histograms: histogram equalization, brightness-preserving bi-histogram equalization, contrast-limited adaptive histogram equalization, end-in search, histogram matching, and exact histogram matching (EHM). Comparison of the results of the different methods was made using three similarity measures peak signal-to-noise ratio, histogram intersection, and structural similarity. Image enhancement of successive bone scans using EHM showed the best results out of the six methods measured for all similarity measures. EHM is the best method of image enhancement based on histograms for diagnosing successive whole-body bone scans. The method for successive whole-body bone scans has the potential to greatly assist radiologists quantify interval changes more accurately and quickly by compensating for the variable nature of intensity information. Consequently, it can improve radiologists' diagnostic accuracy as well as reduce reading time for detecting interval changes.

  1. Whole-body autoradiographic microimaging: Applications in radiopharmaceutical and drug research

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Sacker, D.F.

    1991-01-01

    The whole-body autoradiographic (WBARG) microimaging technique is used for evaluation of the temporo-spatial distribution of radiolabeled molecules in intact animals as well as to determine the sites of accumulation of parent compounds and their metabolites. This technique is also very useful to determine the metabolism of a compound, toxicity, and effects of therapeutic interventions on the distribution of a compound in the whole body, by studying animals at different time intervals after injection of the radiolabeled compound. This report discusses various aspects of WBARG.

  2. Whole-body autoradiographic microimaging: Applications in radiopharmaceutical and drug research

    Energy Technology Data Exchange (ETDEWEB)

    Som, P.; Sacker, D.F.

    1991-12-31

    The whole-body autoradiographic (WBARG) microimaging technique is used for evaluation of the temporo-spatial distribution of radiolabeled molecules in intact animals as well as to determine the sites of accumulation of parent compounds and their metabolites. This technique is also very useful to determine the metabolism of a compound, toxicity, and effects of therapeutic interventions on the distribution of a compound in the whole body, by studying animals at different time intervals after injection of the radiolabeled compound. This report discusses various aspects of WBARG.

  3. Whole-body magnetic resonance imaging and positron emission tomography-computed tomography in oncology.

    Science.gov (United States)

    Schmidt, Gerwin P; Kramer, Harald; Reiser, Maximilian F; Glaser, Christian

    2007-06-01

    The advent of positron emission tomography-computed tomography (PET-CT) and whole-body magnetic resonance imaging (WB-MRI) has introduced tumor imaging with a systemic and functional approach compared with established sequential, multimodal diagnostic algorithms.Whole-body PET with [18F]-fluoro-2-desoxy-glucose is a useful imaging procedure for tumor staging and monitoring that can visualize active tumor tissue by detecting pathological glucose metabolism. The combination of PET with the detailed anatomical information of multislice computed tomography as dual-modality scanners has markedly increased lesion localization and diagnostic accuracy compared with both modalities as standalone applications.Hardware innovations, such as the introduction of multi-receiver channel whole-body MRI scanners at 1.5 and, recently, 3 T, combined with acquisition acceleration techniques, have made high-resolution WB-MRI clinically feasible. Now, a dedicated assessment of individual organs with various soft tissue contrast, spatial resolution, and contrast media dynamics can be combined with whole-body anatomical coverage in a multiplanar imaging approach. More flexible protocols (eg, T1-weighted turbo spin-echo and short inversion recovery imaging, dedicated lung imaging or dynamic contrast-enhanced studies of the abdomen) can be performed within 45 minutes.Whole-body magnetic resonance imaging has recently been proposed for tumor screening of asymptomatic individuals, and potentially life-changing diagnoses, such as formerly unknown malignancy, have been reported. However, larger patient cohort studies will have to show the cost efficiency and the clinical effectiveness of such an approach.For initial tumor staging, PET-CT has proved more accurate for the definition of T-stage and lymph node assessment, mainly because of the missing metabolic information in WB-MRI. However, new applications, such as magnetic resonance whole-body diffusion-weighted imaging or lymphotropic contrast

  4. Total body potassium calibrations for normal and obese subjects in two types of whole body counter

    International Nuclear Information System (INIS)

    Smith, T.; Hesp, R.; Mackenzie, J.

    1979-01-01

    A 42 K calibration technique has been used to compare determinations of total body potassium (TBK) over a wide range of body weights (50.6 to 119.1 kg). Measurements were made using a unique type of liquid scintillation whole-body counter and a conventional NaI whole-body counter. The standard error of an estimate of a TBK of 140 g was in the range 3.0 to 3.4% for both counters. The accuracy of calibration of both counters was shown to provide a sound basis for clinical applications of TBK measurements over a wide range of body weights. (U.K.)

  5. Regulatory guide relating to health physics controls for whole-body dose determination

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Whole-body doses cannot be measured directly when induced by internal exposure. This part of the regulatory guide therefore sets out the criteria determining the requirement for incorporation monitoring and the definition of critical levels by means of fractions of the annual limits for activity intake. Incorporation monitoring is specified to comprise either one or a combination of the following tasks: (1) measurement of radioactivity in the room air at the place of work; (2) direct measurement of radionuclide activities by whole-body or partial body measurements of the monitored person; (3) measurement of radionuclide activities in the excretions of the monitored person. (orig./HP) [de

  6. Relevance of whole body vibration exercise in sport: a short review ...

    African Journals Online (AJOL)

    Background: Whole body vibration exercise (WBVE) has been used as a safe and accessible exercise and important reviews have been published about the use of this exercise to manage diseases and to improve physical conditions of athletes The aim of this paper is to highlight the relevance of WBVE to soccer players, ...

  7. Change in the mineralization of the healing bone callus after whole-body irradiation in mice

    International Nuclear Information System (INIS)

    Drouet, J.; Pleinard, J.F.; Nguyen, T.L.; Goyffon, M.

    The delayed consolidation of diaphysial long-bone fractures in mice subjected to whole-body X-irradiation is expressed biochemically by a faulty mineralization of the repair callus. This deficiency is proportional to the irradiation intensity and is not corrected by previous administration of cycteamine [fr

  8. Whole body MRI in the diagnosis of chronic recurrent multifocal osteomyelitis.

    LENUS (Irish Health Repository)

    Kennedy, M T

    2012-06-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is a diagnosis of exclusion primarily in children and adolescents. As part of the essential criteria for the diagnosis of CRMO, multifocal lesions must be identified. We present the case of an 11-year-old boy with CRMO, whose diagnosis was facilitated by the use of whole body magnetic resonance imaging (WBMR), but not isotope bone scanning.

  9. A biomimetic framework for coordinating and controlling whole body movements in humanoid robots.

    Science.gov (United States)

    Morasso, Pietro; Rea, Francesco; Mohan, Vishwanathan

    2013-01-01

    An integrated model for the coordination of whole body movements of a humanoid robot with a compliant ankle similar to the human case is described. It includes a synergy formation part, which takes into account the motor redundancy of the body model, and an intermittent controller, which stabilizes in a robust way postural sway movements, thus combining the hip strategy with ankle strategy.

  10. Whole-body vibration augments resistance training effects on body composition in postmenopausal women.

    Science.gov (United States)

    Fjeldstad, Cecilie; Palmer, Ian J; Bemben, Michael G; Bemben, Debra A

    2009-05-20

    Age-related changes in body composition are well-documented with a decrease in lean body mass and a redistribution of body fat generally observed. Resistance training alone has been shown to have positive effects on body composition, however, these benefits may be enhanced by the addition of a vibration stimulus. The purpose of this study was to determine the effects of 8 months of resistance training with and without whole-body vibration (WBV) on body composition in sedentary postmenopausal women. Fifty-five women were assigned to resistance only (RG, n=22), vibration plus resistance (VR, n=21) or non-exercising control (CG, n=12) groups. Resistance training (3 sets 10 repetitions 80% strength) was performed using isotonic weight training equipment and whole-body vibration was done with the use of the power plate (Northbrooke, IL) vibration platform for three times per week for 8 months. Total and regional body composition was assessed from the total body DXA scans at baseline (pre) and after 8 months (post) of training. In the VR group, total % body fat decreased from pre- to post-time points (pbody fat (ptraining groups exhibited significant increases in bone free lean tissue mass for the total body, arm and trunk regions from pre to post (ptraining alone and with whole-body vibration resulted in positive body composition changes by increasing lean tissue. However, only the combination of resistance training and whole-body vibration was effective for decreasing percent body fat.

  11. Multifocal non-Hodgkin lymphoma in an infant with cardiac involvement: whole-body MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Jyoti; Seith, Ashu; Sharma, Raju; Kumar, Atin [All India Institute of Medical Sciences, Department of Radiology, New Delhi (India); Bakhshi, Sameer [All India Institute of Medical Sciences, Department of Medical Oncology, New Delhi (India)

    2007-03-15

    Non-Hodgkin lymphoma (NHL) is rare in infancy, and we present a case of aggressive NHL of T-cell lineage in an infant with multifocal bone, cardiac, mediastinal nodal, paranasal sinus, calvarial, and soft-tissue deposits on presentation that were detected on whole-body MRI. (orig.)

  12. Whole-Body versus Local DXA-Scan for the Diagnosis of Osteoporosis in COPD Patients

    Directory of Open Access Journals (Sweden)

    Lidwien Graat-Verboom

    2010-01-01

    Full Text Available Background. Osteoporosis is an extrapulmonary effect of chronic obstructive pulmonary disease (COPD. Diagnosis of osteoporosis is based on BMD measured by DXA-scan. The best location for BMD measurement in COPD has not been determined. Aim of this study was to assess whole-body BMD and BMD of the hip and lumbar spine (local DXA in COPD patients and compare the prevalence of osteoporosis at these locations. Methods. Whole body as well as local DXA-scan were made in 168 COPD patients entering pulmonary rehabilitation. Patient-relevant characteristics were assessed. Prevalence of osteoporosis was determined. Characteristics of patients without osteoporosis were compared to patients with osteoporosis on local DXA. Results. A higher prevalence of osteoporosis was found using local DXA compared to whole-body DXA (39% versus 21%. One quarter of patients without osteoporosis on whole body-DXA did have osteoporosis on local DXA. Significant differences in patient characteristics between patients without osteoporosis based on both DXA measurements and patients with osteoporosis based on local DXA only were found. Conclusions. DXA of the hip and lumbar spine should be made to assess bone mineral density in COPD patients. The lowest T-score of these locations should be used to diagnose osteoporosis.

  13. Effect of whole body resistance training on arterial compliance in young men.

    NARCIS (Netherlands)

    Rakobowchuk, M.; McGowan, C.L.; Groot, P.C.E. de; Bruinsma, D.; Hartman, J.W.; Phillips, S.M.; MacDonald, M.J.

    2005-01-01

    The effect of resistance training on arterial stiffening is controversial. We tested the hypothesis that resistance training would not alter central arterial compliance. Young healthy men (age, 23 +/- 3.9 (mean +/- s.e.m.) years; n = 28,) were whole-body resistance trained five times a week for 12

  14. Metabolism and Whole-Body Fat Oxidation Following Post-Exercise Carbohydrate or Protein Intake

    DEFF Research Database (Denmark)

    Hall, Ulrika Andersson; Pettersson, Stefan; Edin, Fredrik

    2018-01-01

    : Protein supplementation immediately post-exercise did not affect the doubling in whole body fat oxidation seen during a subsequent exercise trial 2 hours later. Neither did it affect resting fat oxidation during the post-exercise period despite increased insulin levels and attenuated ketosis. Carbohydrate...

  15. Effect of whole body vibration exercise on muscle strength and proprioception in females with knee osteoarthritis

    DEFF Research Database (Denmark)

    Trans, T; Aaboe, J; Henriksen, M

    2009-01-01

    The purpose of this study was to assess the effect of whole body vibration (WBV) exercise on muscle strength and proprioception in female patients with osteoarthritis in the knee (knee-OA). A single blinded, randomised, controlled trial was performed in an outpatient clinic on 52 female patients...

  16. Human and animal studies: portals into the whole body and whole population response

    Science.gov (United States)

    Human and animal studies: portals into the whole body and whole population response Michael C. Madden1 and Brett Winters21US Environmental Protection Agency and 2University of North Carolina Human Studies Facility, Chapel Hill, North Carolina, USA Studies involving collection and...

  17. Intermittent fasting does not affect whole-body glucose, lipid, or protein metabolism

    NARCIS (Netherlands)

    Soeters, Maarten R.; Lammers, Nicolette M.; Dubbelhuis, Peter F.; Ackermans, Mariëtte T.; Jonkers-Schuitema, Cora F.; Fliers, Eric; Sauerwein, Hans P.; Aerts, Johannes M.; Serlie, Mireille J.

    2009-01-01

    Background: Intermittent fasting (IF) was shown to increase whole-body insulin sensitivity, but it is uncertain whether IF selectively influences intermediary metabolism. Such selectivity might be advantageous when adapting to periods of food abundance and food shortage. Objective: The objective was

  18. Potential effects of whole-body vibration exercises on blood flow ...

    African Journals Online (AJOL)

    Feasible clinical strategies such as whole-body vibration exercise (WBVE) are being used without a clear understanding of its effects. The aim of the present study is to review the effects of the WBVE on blood flow kinetics and its feasibility in different populations. Material and Methods: The level of evidence (LE) of selected ...

  19. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  20. Evaluation of Massey Ferguson Model 165 Tractor Drivers exposed to whole-body vibration

    Directory of Open Access Journals (Sweden)

    P. Nassiri

    2013-12-01

    Conclusion: This study shows that the need to provide intervention , controlling and managing measures to eliminate or reduce exposure to whole body vibration among tractor drivers its necessary. And, preventing main disorder Including musculoskeletal disorders, discomfort and early fatigue is of circular importance. More studies are also necessary to identify the sources of vibration among various of tractors.

  1. Self-reported back pain in tractor drivers exposed to whole-body vibration

    NARCIS (Netherlands)

    Boshuizen, H. C.; Bongers, P. M.; Hulshof, C. T.

    1990-01-01

    A postal questionnaire on symptoms of ill health and exposure to whole-body vibration was completed by 577 workers (response rate 79%) who were employed in certain functions by two companies 11 years before. The relation between the occupational history of driving vibrating vehicles (mainly

  2. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  3. Acute Effects of Whole Body Vibration on Inhibition in Healthy Children

    NARCIS (Netherlands)

    den Heijer, Anne E.; Groen, Yvonne; Fuermaier, Anselm B. M.; van Heuvelen, Marieke J. G.; van der Zee, Eddy A.; Tucha, Lara; Tucha, Oliver

    2015-01-01

    Objectives Whole Body Vibration (WBV) is a passive exercise method known to have beneficial effects on various physical measures. Studies on adults furthermore demonstrated beneficial effects of WBV treatment on cognition (e.g. inhibition). The present study replicated these findings in healthy

  4. Influence of Tire Characteristics of Interurban Taxis on Exposure Level to Drivers Whole-Body Vibrations

    Directory of Open Access Journals (Sweden)

    Milad Derakhshanjazari

    2016-03-01

    Full Text Available Introduction: Taxi drivers’ exposure to repeat whole-body vibrations can cause back pain and digestive disorders. Since this type of vibration depends on the car components, this study was carried out to determine the influence of tire characteristics on the amount of whole-body vibrations transmitted to the Peugeot 405 taxi drivers. Methods: In this experimental study, vibration characteristics were measured according to the ISO2631-1 with each of the statuses: tubeless tires fixed and fluid in it (normal air or nitrogen and also the fluid in the tires fixed with tubes or tubeless on asphalt-paved road. Other variables including tire pressure, engine speed, road gradient, number of passengers, springs, and shock absorbers were kept constant. Then the effect of changes was analyzed using an appropriate statistical test. Results: After changing nitrogen to normal air and tubeless tires to tube, the average of RMS in Z-axis, eight-hour equivalent acceleration A(8 and crest factor were reduced (P 0.9 m/s2 to caution zone (0.45-0.9 m/s2 with a value of 0.8 m/s2. Conclusions: The amount of vibration transmitted to the whole body is sensitive to existence of tubes and tires inflation so that we can reduce the amount of whole-body vibration to lower than the upper limit of the health risk by changing the characteristics of the tire

  5. A photographic technique for teaching topographical anatomy from whole body transverse sections.

    Science.gov (United States)

    Logan, B M; Liles, R P; Bolton, I

    1990-04-01

    A photographic technique is described which enables the production of a series of 35 mm transparencies for teaching topographical anatomy from whole body transverse sections. It shows the sequential build-up of a section from an easily identifiable individual structure to the whole, therefore allowing the viewer to identify important areas and key structures within a section more readily.

  6. Back disorders in crane operators exposed to whole-body vibration

    NARCIS (Netherlands)

    Bongers, P. M.; Boshuizen, H. C.; Hulshof, C. T.; KOEMEESTER, A. P.

    1988-01-01

    In The Netherlands so far little research has been carried out to investigate the health effects of exposure to whole-body vibration at work. In a retrospective (10-year) follow-up study, the incidence of permanent work disabilities in crane operators exposed to vibration was compared to that of a

  7. A statistical observation on some subjects in the whole body computed tomographic examination

    International Nuclear Information System (INIS)

    Murakami, Shozo; Matsumoto, Shigekazu; Murakawa, Yasuhiro; Morimoto, Mitsuo; Nakai, Toshio

    1983-01-01

    Since the whole body CT (computed tomography) unit (GE, CT/T) was installed in our hospital in April, 1982, a total of 2884 cases have been examined by this whole body scanner for one year from April, 1982 to March, 1983. An analysis of the relationship between the situations of the subjects in and the results of whole body CT examination disclosed some very interesting facts. Up to the present time such a study has scarcely made. That is why we wanted to make this report. The results obtained are as follows: 1. Whole body CT examinations were performed on the patients of advanced age more frequently than on those of young age and performed most frequently on the group in the sixties. 2. The number of CT examinations performed on head and abdomen of the patients was 86.7% of a total of 2884 cases. 3. Enhanced CT examinations were perfomed on 26.1% of 2884 cases and most frequently on the group in the teens. 4. The percentage of the abnormal findings found in 2884 cases was 61.5% and this rate was higher than that shown in the reports made by us in 1980 and 1982, respectively. (author)

  8. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    The whole body clearance of noradrenaline (NA) was measured in seven patients pre- and postoperatively. L-3H-NA was infused intravenously for 90 min and steady-state concentrations of L-3H-NA were measured in both arterial and peripheral venous blood. Preoperatively, in the resting supine position...

  9. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  10. Inter-station Intensity Standardization for Whole-Body MR Data

    NARCIS (Netherlands)

    Dzyubachyk, Oleh; Staring, M.; Reijnierse, Monique; Lelieveldt, B.P.F.; van der Geest, Rob J.

    2017-01-01

    Purpose To develop and validate a method for performing inter-station intensity standardization in multispectral whole-body MR data. Methods Different approaches for mapping the intensity of each acquired image stack into the reference intensity space were developed and validated. The registration

  11. Monte Carlo calculation of efficiencies of whole-body counter, by microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computer programming using the Monte Carlo method for calculation of efficiencies of whole-body counting of body radiation distribution is presented. An analytical simulator (for man e for child) incorporated with 99m Tc, 131 I and 42 K is used. (M.A.C.) [pt

  12. Effect of whole-body vibration on muscle strength, spasticity, and ...

    African Journals Online (AJOL)

    Marwa M. Ibrahim

    Abstract Background and purpose: Spastic diplegia is a common form of cerebral palsy (CP) and is characterized by spasticity and muscle weakness of both lower limbs resulting in decreased walk- ing ability. The purpose of this study was to evaluate the effect of whole body vibration (WBV) training on muscle strength, ...

  13. An update on novel quantitative techniques in the context of evolving whole-body PET imaging

    DEFF Research Database (Denmark)

    Houshmand, Sina; Salavati, Ali; Hess, Søren

    2015-01-01

    for quantification and correction of PET parameters, there is debate on the selection of the appropriate methodology in specific diseases and conditions. In this review, we have focused on these techniques with special attention to topics such as static and dynamic whole body PET imaging, tracer kinetic modeling...

  14. Early and late allergic reaction in the nose assessed by whole body plethysmography

    NARCIS (Netherlands)

    de Bruin-Weller, M. S.; Weller, F. R.; Scholte, A.; Rijssenbeek, L. H.; van der Baan, S.; Bogaard, J. M.; de Monchy, J. G.

    1996-01-01

    Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting

  15. Early and late allergic reaction in the nose assessed by whole body plethysmography

    NARCIS (Netherlands)

    deBruinWeller, MS; Weller, FR; Scholte, A; Rijssenbeek, LHM; vanderBaan, S; Bogaard, JM; deMonchy, JGR

    Physiological changes during late phase nasal responses after allergen challenge are difficult to establish and different criteria are used for the definition of a positive late phase nasal reaction. The objective of this study was to assess the value of whole body plethysmography in detecting

  16. Comparative evaluation of nose-only vs. whole-body inhalation exposures for rats

    International Nuclear Information System (INIS)

    Yeh, H.C.; Snipes, M.B.; Eidson, A.F.; Hobbs, C.H.

    1988-01-01

    Two types of rat exposure chambers, nose-only and whole-body chambers, were evaluated simultaneously for the temporal and spatial distribution of the same test aerosols within the chambers, both with and without animals present. Results indicated that both types of exposure chambers performed well, with coefficients of variation less than 10% for both temporal and spatial variations. (author)

  17. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  18. Mitochondrial monoaminoxidase activity and serotonin content in rat brain after whole-body γ-irradiation

    International Nuclear Information System (INIS)

    Savitskij, I.V.; Tsybul'skij, V.V.; Grivtsev, B.A.

    1985-01-01

    It is shown that γ-irradiation of albino rats with a dose of 30 Gy leads to pronounced phase changes in monoaminoxidase activity and serotonin content in rat brain at early times after whole-body exposure. These is a similar direction of changes in the activity of the enzyme and in the content of the substrate adequate to the latter

  19. Effects of whole-body vibration on muscle strength and power of elderly: A systematic review

    Directory of Open Access Journals (Sweden)

    Monique Opuszcka Campos

    2014-02-01

    Full Text Available The aim of this systematic review was to summarize available scientific evidence on the utilization of whole body vibration as an alternative method to promote effective modifications on muscle strength and power in the aging population.  Scientific studies were retrieved from the following databases: Medline, Scielo, Lillacs, Cochrane Library, PEDro and Science Citation Index. The PEDro scale was used to assess the quality of the included studies, while content went through a critical analysis. From the 91 studies retrieved, 75 were excluded and 16 attended the selection criteria. From the16, the majority (68.8% presented from moderate to high methodological quality. Whole-body vibration associated to both isometric and dynamic exercises seemed to constitute an alternative for therapeutic intervention to improve muscular strength and power of healthy elderly. However, due to the characteristics of the designs of the studies reviewed and the threats to their internal validity (i.e., the absence of the control condition to the vibratory stimulus it was challenging to establish the additional effects of the whole-body vibration on the target population. Divergent findings were found for the whole-body vibration effect on muscular power. It is still necessary to conduct randomized control trials to establish the real effectiveness of this kind of intervention.

  20. Whole body heat stress attenuates the pressure response to muscle metaboreceptor stimulation in humans

    Science.gov (United States)

    Cui, Jian; Blaha, Cheryl

    2016-01-01

    The effects of whole body heat stress on sympathetic and cardiovascular responses to stimulation of muscle metaboreceptors and mechanoreceptors remains unclear. We examined the muscle sympathetic nerve activity (MSNA), blood pressure, and heart rate in 14 young healthy subjects during fatiguing isometric handgrip exercise, postexercise circulatory occlusion (PECO), and passive muscle stretch during PECO. The protocol was performed under normothermic and whole body heat stress (increase internal temperature ~0.6°C via a heating suit) conditions. Heat stress increased the resting MSNA and heart rate. Heat stress did not alter the mean blood pressure (MAP), heart rate, and MSNA responses (i.e., changes) to fatiguing exercise. During PECO, whole body heat stress accentuated the heart rate response [change (Δ) of 5.8 ± 1.5 to Δ10.0 ± 2.1 beats/min, P = 0.03], did not alter the MSNA response (Δ16.4 ± 2.8 to Δ17.3 ± 3.8 bursts/min, P = 0.74), and lowered the MAP response (Δ20 ± 2 to Δ12 ± 1 mmHg, P heat stress prevented the MAP and MSNA responses to stretch during PECO (both P > 0.05). These data suggest that whole body heat stress attenuates the pressor response due to metaboreceptor stimulation, and the sympathetic nerve response due to mechanoreceptor stimulation. PMID:27763873

  1. Report on whole-body counting at nuclear facilities in North America

    International Nuclear Information System (INIS)

    Haskins, A.W.; Earls, L.M.; Hudson, C.G.

    1982-06-01

    Because of increasing reliance upon whole-body counting for routine monitoring of radiation workers in the nuclear industry, a survey was conducted to determine its current status at nuclear facilities in North America. Information on this subject was obtained by means of confidential questionnaires sent to nuclear power plants, national laboratories, and other nuclear facilities in the United States and Canada, followed up by personal communications with randomly-selected respondents. A return rate of over 75% of those surveyed indicates strong interest in the exchange of ideas on whole-body counting, an endeavor which appears to have been neglected in the past. Information obtained in this survey was tabulated and several correlations were made which should be of value for improvement and standardization of existing whole-body counting programs as well as those which are in the planning stage. Categories dealt with in this paper include: instrumentation and equipment, data processing, operator training and qualifications, investigation and action levels, and future trends in the philosophy of whole-body counting

  2. Whole-body CO2 production as an index of the metabolic response to sepsis

    Science.gov (United States)

    Whole-body carbon dioxide (CO2) production (RaCO2) is an index of substrate oxidation and energy expenditure; therefore, it may provide information about the metabolic response to sepsis. Using stable isotope techniques, we determined RaCO2 and its relationship to protein and glucose metabolism in m...

  3. Whole-Body versus Local DXA-Scan for the Diagnosis of Osteoporosis in COPD Patients

    NARCIS (Netherlands)

    Graat-Verboom, L.; Spruit, M.A.; van den Borne, B.E.; Smeenk, F.W.; Wouters, E.F.M.

    2010-01-01

    Background. Osteoporosis is an extrapulmonary effect of chronic obstructive pulmonary disease (COPD). Diagnosis of osteoporosis is based on BMD measured by DXA-scan. The best location for BMD measurement in COPD has not been determined. Aim of this study was to assess whole-body BMD and BMD of the

  4. Head-to-toe whole-body MRI in psoriatic arthritis, axial spondyloarthritis and healthy subjects

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Pedersen, Susanne Juhl; Eshed, Iris

    2015-01-01

    OBJECTIVES: By whole-body MRI (WBMRI), we aimed to examine the frequency and distribution of inflammatory and structural lesions in PsA patients, SpA patients and healthy subjects (HSs), to introduce global WBMRI inflammation/damage scores, and to assess WBMRI's reproducibility and correlation wi...

  5. Whole-body vibration exercise is well tolerated in patients with ...

    African Journals Online (AJOL)

    Background: Duchenne muscular dystrophy (DMD) is caused by a defective gene located on the X-chromosome, responsible for the production of the dystrophin protein. Complications in the musculoskeletal system have been previously described in DMD patients. Whole body vibration exercise (WBVE) is a treatment that ...

  6. Moving along the Mental Number Line: Interactions between Whole-Body Motion and Numerical Cognition

    Science.gov (United States)

    Hartmann, Matthias; Grabherr, Luzia; Mast, Fred W.

    2012-01-01

    Active head turns to the left and right have recently been shown to influence numerical cognition by shifting attention along the mental number line. In the present study, we found that passive whole-body motion influences numerical cognition. In a random-number generation task (Experiment 1), leftward and downward displacement of participants…

  7. Amino acid metabolism and whole-body protein turnover in lambs ...

    African Journals Online (AJOL)

    but all estimates for the high-protein diet were significantly different (P < 0.06). The same trend was apparent in the case of whole-body protein synthesis, but leucine and methionine provided similar estimates for the high-protein diet. It was suggested that, although much stands to be gained from studies of the metabolism of ...

  8. Use of extremity insulation during whole body hyperthermia to reduce temperature nonuniformity

    International Nuclear Information System (INIS)

    Thrall, D.E.; Page, R.L.

    1987-01-01

    The author previously documented during whole body hyperthermia in dogs using a radiant heating device that temperature at superficial sites, including tibial bone marrow, falls below systemic arterial temperature during the plateau phase of heating. This may be due to direct heat loss to the environment. Sites where temperature is lower than systemic arterial temperature during the plateau phase may become sanctuary sites where tumor deposits are spared because they do not receive the prescribed thermal dose. In an attempt to decrease temperature nonuniformity and increase thermal dose delivered to such superficial sites, extremity insulation has been employed during whole body hyperthermia in dogs. The author measured temperature at cutaneous and subcutaneous sites and within tibial bone marrow in insulated and noninsulated extremities of dogs undergoing whole body hyperthermia in the radiant heating device. The author found that extremity insulation is effective in reducing extremity temperature nonuniformity. Specific results are presented. Extremity insulation may be necessary during whole body hyperthermia to assure that extremity tumor deposits receive a thermal dose similar to that prescribed for the entire body

  9. Amino acid metabolism and whole-body protein turnover in lambs ...

    African Journals Online (AJOL)

    The effect of protein supplementation of a wheat straw diet on the metabolism of lysine, leucine, methionine and urea, and on whole-body protein turnover rate was investigated in lambs. The metabolism of lysine and leucine is reported elsewhere (Cronje et aI., 1992); in this paper methionine metabolism is discussed, and ...

  10. Serum lathosterol concentration is an indicator of whole-body cholesterol synthesis in humans.

    NARCIS (Netherlands)

    Kempen, H.J.M.; Glatz, J.F.C.; Gevers Leuven, J.A.; Voort, van der H.A.; Katan, M.B.

    1988-01-01

    The power of serum lathosterol concentration as an indicator of whole- body cholesterol synthesis was investigated in 47 human volunteers consuming two diets differing in fatty acid composition. The cholesterol balance (fecal excretion of neutral and acid steroids minus cholesterol intake) was

  11. Serum lathosterol concentration is an indicator of whole-body cholesterol synthesis in humans

    NARCIS (Netherlands)

    Kempen, H.J.M.; Glatz, J.F.C.; Gevers Leuven, J.A.; Voort, H.A. van der; Katan, M.B.

    1988-01-01

    The power of serum lathosterol concentration as an indicator of whole-body cholesterol synthesis was investigated in 47 human volunteers consuming two diets differing in fatty acid composition. The cholesterol balance (fecal excretion of neutral and acid steroids minus cholesterol intake) was

  12. Menopause is associated with decreased whole body fat oxidation during exercise

    DEFF Research Database (Denmark)

    Abildgaard, J; Pedersen, A T; Green, C J

    2013-01-01

    biking at 50% of maximal oxygen consumption (Vo2 max). Muscle biopsies from the vastus lateralis of the quadriceps muscle were obtained before and immediately after the exercise bout. Postmenopausal women had 33% [confidence interval (CI) 95%: 12-55] lower whole body fat oxidation (P = 0.005) and 19% (CI...

  13. Head Exposure to Cold during Whole-Body Cryostimulation: Influence on Thermal Response and Autonomic Modulation.

    Directory of Open Access Journals (Sweden)

    Julien Louis

    Full Text Available Recent research on whole-body cryotherapy has hypothesized a major responsibility of head cooling in the physiological changes classically reported after a cryostimulation session. The aim of this experiment was to verify this hypothesis by studying the influence of exposing the head to cold during whole-body cryostimulation sessions, on the thermal response and the autonomic nervous system (ANS. Over five consecutive days, two groups of 10 participants performed one whole-body cryostimulation session daily, in one of two different systems; one exposing the whole-body to cold (whole-body cryostimulation, WBC, and the other exposing the whole-body except the head (partial-body cryostimulation, PBC.10 participants constituted a control group (CON not receiving any cryostimulation. In order to isolate the head-cooling effect on recorded variables, it was ensured that the WBC and PBC systems induced the same decrease in skin temperature for all body regions (mean decrease over the 5 exposures: -8.6°C ± 1.3°C and -8.3 ± 0.7°C for WBC and PBC, respectively, which persisted up to 20-min after the sessions (P20. The WBC sessions caused an almost certain decrease in tympanic temperature from Pre to P20 (-0.28 ± 0.11°C, while it only decreased at P20 (-0.14 ± 0.05°C after PBC sessions. Heart rate almost certainly decreased after PBC (-8.6% and WBC (-12.3% sessions. Resting vagal-related heart rate variability indices (the root-mean square difference of successive normal R-R intervals, RMSSD, and high frequency band, HF were very likely to almost certainly increased after PBC (RMSSD:+49.1%, HF: +123.3% and WBC (RMSSD: +38.8%, HF:+70.3%. Plasma norepinephrine concentration was likely increased in similar proportions after PBC and WBC, but only after the first session. Both cryostimulation techniques stimulated the ANS with a predominance of parasympathetic tone activation from the first to the fifth session and in slightly greater proportion with

  14. Whole-body vibration slows the acquisition of fat in mature female rats.

    Science.gov (United States)

    Maddalozzo, G F; Iwaniec, U T; Turner, R T; Rosen, C J; Widrick, J J

    2008-09-01

    To evaluate the effects of whole-body vibration on fat, bone, leptin and muscle mass. Thirty 7-month-old female 344 Fischer rats were randomized by weight into three groups (baseline, vibration or control; n=8-10 per group). Rats in the vibration group were placed inside individual compartments attached to a Pneu-Vibe vibration platform (Pneumex, Sandpoint, ID, USA) and vibrated at 30-50 Hz (6 mm peak to peak) for 30 min per day, 5 days per week, for 12 weeks. The vibration intervention consisted of six 5-min cycles with a 1-min break between cycles. There were significant body composition differences between the whole-body vibration and the control group. The whole-body vibration group weighed approximately 10% less (mean+/-s.d.; 207+/-10 vs 222+/-15 g, P<0.03) and had less body fat (20.8+/-3.8 vs 26.8+/-5.9 g, P<0.05), a lower percentage of body fat (10.2+/-1.7 vs 12+/-2.0%, P<0.05), and lower serum leptin levels (1.06+/-0.45 vs 2.27+/-0.57 ng ml(-1), P<0.01) than the age-matched controls. No differences were observed for total lean mass, bone mineral content (BMC), bone mineral density (BMD), insulin-like growth factor-I (IGF-I) or soleus (SOL) and extensor digitorum longus (EDL) mass or function. Regional high-resolution dual-energy X-ray absoptiometry scans of the lumbar spine (L1-4) revealed that the whole-body vibration group had significantly greater BMC (0.33+/-0.05 vs 0.26+/-0.03 g, P<0.01) and BMD (0.21+/-0.01 vs 0.19+/-0.01 g cm(-2), P<0.01) than the control group. No differences between the groups were observed in the amount of food consumed. These findings show that whole-body vibration reduced body fat accumulation and serum leptin without affecting whole body BMC, BMD or lean mass. However, the increase in vertebral BMC and BMD suggests that vibration may have resulted in local increases in bone mass and density. Also, whole-body vibration did not affect muscle function or food consumption.

  15. [Complaints of low back pain among private farmers exposed to whole body vibration].

    Science.gov (United States)

    Solecki, Leszek

    2014-01-01

    Work-related lower back disorders, which involve the lumbo-sacral region, as well as injuries of the lumbar section of the spine, are a serious and constantly growing problem in Europe. Whole body vibration is one of the major hazardous factors suspected of the development of back pain. The study covered a selected group of males, 98 farmers (aged 55.3 +/- 10.1) from the area of 7 communes in the Lublin Region, engaged in the mixed agricultural production (plant-animal). The control group consisted of 40 academic workers (university and research institute employees) aged 48.9 +/- 9.6 years. A questionnaire concerning low back pain (in the lumbar region) designed by the researchers of the Institute of Rural Health in Lublin was used as a major research tool. The degree of farmers' exposure to whole body vibration was evaluated based on the parameter known as a cumulative vibration dose (d) (years x m2 x s(-1)). The measurements showed that the cumulative vibration dose for the selected group of farmers (98) remained within the range of 2.90-9.68 (years x m2 x s(-1)), in the time interval between 15-50 years of work in conditions of exposure to vibration. The survey confirmed that private farmers exposed to whole body vibration considerably more frequently complained of back pain (92 farmers, 94% of the total number of respondents), than academic workers (control group not exposed to whole body vibration (25 researchers, 63%); p farmers than in the control group (p farmers during the entire period of occupational activity increases with a growing dose of whole body vibration (p = 0.005). In the incidence of chronic pain an upward tendency was observed (statistically insignificant).

  16. USE OF WHOLE-BODY VIBRATION AS A MODE OF WARMING UP BEFORE COUNTER MOVEMENT JUMP

    Directory of Open Access Journals (Sweden)

    Enrique G. Artero

    2007-12-01

    Full Text Available Whole-body vibration (WBV has been suggested to be particularly effective on the stretch-shortening cycle-based movements, such as the counter movement jump (CMJ test (Issurin, 2005. Nevertheless, the literature on short-term vibration exposure and lower limb explosive performance (measured by CMJ test is contradictory. Either transient improvements (Bosco et al., 2000; Cochrane and Stannard, 2005; Torvinen et al., 2002a or no effects (Torvinen et al., 2002b; Rittweger et al., 2003; Cormie et al., 2006 have been reported after a single WBV exposure ranging from 30 s to 10 min. The present study aimed at better characterizing the use of a single short bout of WBV as a mode of warming up before a CMJ test.A total of 114 university students (37 men, 77 women, aged 19.6 ± 2.0 years signed an informed consent form and volunteered to participate in the study. The study protocol was approved by the Review Committee for Research Involving Human Subjects of our center. Participants were asked to come to the laboratory in three occasions three days apart. First visit: familiarization session aiming to learn the CMJ technique and to experience the vibration stimulus. Second visit: the participants performed three consecutive CMJ with one min rest interval. No significant differences were observed among the jumps, and the highest score was retained. Third visit: the participants were exposed to a single short bout of WBV and immediately after they performed three CMJ with one min rest interval.An infrared contact timing platform (ERGO JUMP Plus - BOSCO SYSTEM, Byomedic, S.C.P., Barcelona, Spain was used to measure "flight" time (t during the vertical jump (accuracy 0.001 s. Maximum height achieved by the body centre of gravity (h was then estimated, i.e. h = g · t2 / 8, where g = 9.81 m/s2. In all occasions, the participants were instructed to abstain from strenuous exercise for the preceding 24 hours.Whole-body vibration was carried out on an oscillating

  17. Contrast-enhanced bolus-chased whole-body MR angiography using a moving tabletop and quadrature body coil acquisition.

    Science.gov (United States)

    Brennan, Darren D; Johnston, Ciaran; O'Brien, Julie; Taylor, David H; Cronin, Carmel; Eustace, Stephen J

    2005-09-01

    MR angiography is now an established technique for the evaluation of various arterial structures. With recent developments in hardware, whole-body imaging has become technically feasible. The aim of this study is to describe a technique for whole-body MR angiography using a quadrature body coil and a moving tabletop. Whole-body MR angiography is technically feasible and may offer a method of screening for unsuspected disease.

  18. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  19. The TOBY Study. Whole body hypothermia for the treatment of perinatal asphyxial encephalopathy: A randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Thoresen Marianne

    2008-04-01

    Full Text Available Abstract Background A hypoxic-ischaemic insult occurring around the time of birth may result in an encephalopathic state characterised by the need for resuscitation at birth, neurological depression, seizures and electroencephalographic abnormalities. There is an increasing risk of death or neurodevelopmental abnormalities with more severe encephalopathy. Current management consists of maintaining physiological parameters within the normal range and treating seizures with anticonvulsants. Studies in adult and newborn animals have shown that a reduction of body temperature of 3–4°C after cerebral insults is associated with improved histological and behavioural outcome. Pilot studies in infants with encephalopathy of head cooling combined with mild whole body hypothermia and of moderate whole body cooling to 33.5°C have been reported. No complications were noted but the group sizes were too small to evaluate benefit. Methods/Design TOBY is a multi-centre, prospective, randomised study of term infants after perinatal asphyxia comparing those allocated to "intensive care plus total body cooling for 72 hours" with those allocated to "intensive care without cooling". Full-term infants will be randomised within 6 hours of birth to either a control group with the rectal temperature kept at 37 +/- 0.2°C or to whole body cooling, with rectal temperature kept at 33–34°C for 72 hours. Term infants showing signs of moderate or severe encephalopathy +/- seizures have their eligibility confirmed by cerebral function monitoring. Outcomes will be assessed at 18 months of age using neurological and neurodevelopmental testing methods. Sample size At least 236 infants would be needed to demonstrate a 30% reduction in the relative risk of mortality or serious disability at 18 months. Recruitment was ahead of target by seven months and approvals were obtained allowing recruitment to continue to the end of the planned recruitment phase. 325 infants were

  20. Determining the influence of Korean population variation on whole-body average SAR.

    Science.gov (United States)

    Lee, Ae-Kyoung; Choi, Hyung-Do

    2012-05-07

    Compliance of the ICNIRP reference and IEEE action levels with the basic restrictions on whole-body average (WBA) SAR was investigated based on age, physique, and posture under isolated and grounded conditions. First, Korean male models 1, 3, 5, 7, and 20 years of age with body sizes in the 50th percentile were developed and used as the test subjects: 1y(50th), 3y(50th), 5y(50th), 7y(50th), and 20y(50th). The effects of age-dependent dielectric properties due to the water content of the tissue on WBA SAR were analysed, and showed that the changes in WBA SAR are marginal. At the ages of 1, 5, and 20, thin models 1y(10th), 5y(10th), and 20y(10th) with body sizes in the 10th percentile for the horizontal plane were added in order to determine the influence of physical variations of the population. We considered standing postures with arms up and arms down. The WBA SAR for each human model was calculated when exposed to a vertically polarized plane wave in the frequency range of 10 MHz-3 GHz using the finite-difference time-domain method. The evaluated WBA SAR-based safety factor of each model is discussed for exposure to the ICNIRP reference and IEEE action levels. Finally, the lowest external electric field strength required to produce the basic restrictions on the WBA SAR, 0.08 W kg(-1), was obtained. The results showed that the ICNIRP public reference level is not conservative in the frequency range of 20-200 MHz for an arms-up posture, in the range of 40-200 MHz for an arms-down posture, and above 1 GHz for both postures. The IEEE action level is different from the ICNIRP reference level below 30 MHz, where most cases showed a safety factor of less than 50, which is the minimum value compliant with the basic restrictions for exposure to the general public.

  1. Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

    LENUS (Irish Health Repository)

    Gleeson, T G

    2009-03-01

    The aim of the study is to assess the feasibility of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of multiple myeloma and compare to skeletal survey (SS), using bone marrow biopsy and whole-body magnetic resonance imaging (WBMRI; where available) as gold standard.

  2. Bases for calibration of whole body counters using anthropomorphic physical simulators

    International Nuclear Information System (INIS)

    Dantas, Bernardo Maranhao

    1998-01-01

    The quantification of radionuclides in the human body can be carried out through in vivo measurements performed in facilities generically called whole body counters. The calibration of such units is usually done by using physical anthropomorphic phantoms, which can be defined as artificial structures with geometrical characteristics and attenuation properties similar to the living tissues. This work presents the development of the phantoms necessary to the monitoring of the internal contamination by the radionuclides manipulated in Brazil. It also presents the procedures for the calibration of the detectors used for the in vivo measurements. The developed phantoms are applied in the determination of radionuclides deposited in specific organs, such as Th-232 and Am-241 in the lungs and skull, isotopes of iodine in the thyroid and photon emitters in the energy range from 100 to 3000 keV in the whole body. (author)

  3. MRI compatible small animal monitoring and trigger system for whole body scanners

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Karl-Heinz; Krumbein, Ines; Reichenbach, Juergen R. [Jena University Hospital (Germany). Medical Physics Group; Pfeiffer, Norman [Jena University Hospital (Germany). Medical Physics Group; Ernst-Abbe-Fachhochschule Jena (Germany); Herrmann, Lutz [Ernst-Abbe-Fachhochschule Jena (Germany)

    2014-03-01

    Performing magnetic resonance imaging (MRI) experiments with small animals requires continuous monitoring of vital parameters, especially the respiration rate. Clinical whole-body MR scanners represent an attractive option for preclinical imaging as dedicated animal scanners are cost-intensive in both investment and maintenance, thus limiting their availability. Even though impressive image quality is achievable with clinical MR systems in combination with special coils, their built-in physiologic monitoring and triggering units are often not suited for small animal imaging. In this work, we present a simple, MRI compatible low cost solution to monitor the respiration and heart rate of small animals in a clinical whole-body MR scanner. The recording and processing of the biosignals as well as the optimisation of the respiratory trigger generation is described. Additionally rat and mouse in-vivo MRI experiments are presented to illustrate the effectiveness of the monitoring and respiratory trigger system in suppressing motion artifacts. (orig.)

  4. Brain-machine interfacing control of whole-body humanoid motion

    Science.gov (United States)

    Bouyarmane, Karim; Vaillant, Joris; Sugimoto, Norikazu; Keith, François; Furukawa, Jun-ichiro; Morimoto, Jun

    2014-01-01

    We propose to tackle in this paper the problem of controlling whole-body humanoid robot behavior through non-invasive brain-machine interfacing (BMI), motivated by the perspective of mapping human motor control strategies to human-like mechanical avatar. Our solution is based on the adequate reduction of the controllable dimensionality of a high-DOF humanoid motion in line with the state-of-the-art possibilities of non-invasive BMI technologies, leaving the complement subspace part of the motion to be planned and executed by an autonomous humanoid whole-body motion planning and control framework. The results are shown in full physics-based simulation of a 36-degree-of-freedom humanoid motion controlled by a user through EEG-extracted brain signals generated with motor imagery task. PMID:25140134

  5. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... simulations with the Finite-Difference Time-Domain method. Furthermore, the method accounts for the diffuse multipath components (DMC) in the total absorption rate by considering the reverberation time of the investigated room, which describes all the losses in a complex indoor environment. The advantage...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  6. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  7. Whole body and tissue blood volumes of two strains of rainbow trout (Oncorhynchus mykiss)

    Science.gov (United States)

    Gingerich, W.H.; Pityer, R.A.; Rach, J.J.

    1990-01-01

    1. Estimates of apparent packed cell, plasma and total blood volumes for the whole body and for 13 selected tissues were compared between Kamloops and Wytheville strains of rainbow trout (Oncorhynchus mykiss) by the simultaneous injection of two vascular tracers, radiolabeled trout erythrocytes (51Cr-RBC) and radioiodated bovine serum albumin (125I-BSA).2. Whole body total blood volume, plasma volume and packed cell volume were slightly, but not significantly greater in the Wytheville trout, whereas, the apparent plasma volumes and total blood volumes in 4 of 13 tissues were significantly greater in the Kamloops strain.3. Differences were most pronounced in highly perfused organs, such as the liver and kidney and in organs of digestion such as the stomach and intestines.4. Differences in blood volumes between the two strains may be related to the greater permeability of the vascular membranes in the Kamloops strain fish.

  8. A review of whole-body counting techniques appropriate to the study of gastrointestinal absorption

    International Nuclear Information System (INIS)

    Boddy, K.

    1976-01-01

    The wide range of whole-body counters in use for, or applicable to, the study of gastrointestinal absorption is reviewed. Shielded-room or high-sensitivity shadow-shield counters will generally be required only when there is a separate need to measure total body potassium or in studies involving pregnancy or children. For measuring gastrointestinal absorption per se, it is concluded that very simple whole-body counters of the shadow-shield or partial-shield type are usually satisfactory. These systems are of lower cost, and an economic justification for their use is derived by comparing their costs with those of hospitalizing patients for alternative investigations of gastrointestinal absorption. A resume of the general methodology is presented and some operational features and precautions are described. (author)

  9. Whole-body kinetics and dosimetry of cis-4-[18F]fluoro-l-proline

    International Nuclear Information System (INIS)

    Boerner, Anne R.; Langen, Karl-J.; Herzog, Hans; Hamacher, Kurt; Mueller-Mattheis, Volker; Schmitz, Thomas; Ackermann, Rolf; Coenen, Heinz H.

    2001-01-01

    The whole-body distribution of 4-cis[ 18 F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 μGy/MBq). The effective dose according to ICRP 60 was 15.1 μSv/MBq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro

  10. Whole-body kinetics and dosimetry of cis-4-[{sup 18}F]fluoro-l-proline

    Energy Technology Data Exchange (ETDEWEB)

    Boerner, Anne R.; Langen, Karl-J. E-mail: k.j.langen@fz-juelich.de; Herzog, Hans; Hamacher, Kurt; Mueller-Mattheis, Volker; Schmitz, Thomas; Ackermann, Rolf; Coenen, Heinz H

    2001-04-01

    The whole-body distribution of 4-cis[{sup 18}F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 {mu}Gy/MBq). The effective dose according to ICRP 60 was 15.1 {mu}Sv/MBq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro.

  11. Whole-body kinetics and dosimetry of cis-4-[(18)F]fluoro-L-proline.

    Science.gov (United States)

    Börner, A R; Langen, K J; Herzog, H; Hamacher, K; Müller-Mattheis, V; Schmitz, T; Ackermann, R; Coenen, H H

    2001-04-01

    The whole-body distribution of 4-cis[(18)F]fluoro-L-proline (cis-FPro) was studied in six patients with urological tumors by PET. Based on the IMEDOSE and MIRDOSE procedures radiation absorbed doses were estimated from whole-body PET scans acquired at 1 and 3-5 h after i.v. injection of 400 MBq cis-FPro. Cis-FPro showed high retention in the renal cortex and a slight uptake in liver and pancreas. Urinary excretion ranged from 12 to 19% at 5 h p.i. Highest absorbed doses were found for the urinary bladder wall and the kidneys (44.1/44.0 microGy/mbq). The effective dose according to ICRP 60 was 15.1 microSv/mbq for adults. This leads to an effective dose of 6.0 mSv in a PET study using 400 MBq cis-FPro.

  12. Determination of iron absorption and excretion by whole-body counting

    International Nuclear Information System (INIS)

    Hollard, D.; Benabid, Y.; Berard, M.; Bonnin, J.; Darnault, J.; Millet, M.

    1969-01-01

    Using a whole-body counter, the authors have studied 59 Fe absorption and loss in 8 normal subjects and in 30 iron deficient patients. Results showed that whole-body counting provided an excellent and simple method for iron retention measurements, obviating many inaccuracies of previous technic. Normal absorption of radio iron with this procedure has ranged from 9 per cent to 20 per cent of the administered tracer in normal subjects, with a mean of 15 per cent. A significant increase in 59 Fe absorption was noted in 21 iron-deficient patients in whom the retention ranged from 40 to 100 per cent. However, 3 iron-deficient patients were found to have low absorption, and their severe iron deficiency could be correlated with this defect in absorption. This method permits also the determination of the rate of iron excretion during the following months and therefore the study of the mechanism of some pathological loss. (authors) [fr

  13. Learning Letters With the Whole Body: Visuomotor Versus Visual Teaching in Kindergarten.

    Science.gov (United States)

    Bara, Florence; Bonneton-Botté, Nathalie

    2018-02-01

    What constitutes effective teaching of letter learning in early school years is still uncertain. We assessed the impact of a teacher-implemented visuomotor intervention program to teach 5-year-olds' cursive letter knowledge. We compared a program in which letters were explored with the arm and whole body, with a typical visual training program. Children were tested before and after the intervention with different measures of letter knowledge. We showed a greater improvement in letter recognition following the visuomotor intervention, compared with the visual intervention. Results were mixed for letter handwriting for which we found higher scores on stroke direction and overall quality, but lower scores on fluency following whole body visuomotor teaching. We discuss our results in terms of the link between action and perception, the interaction between the different components of letter knowledge, and the link between fine and gross motor development and handwriting.

  14. Vestibular-somatosensory interactions: effects of passive whole-body rotation on somatosensory detection.

    Directory of Open Access Journals (Sweden)

    Elisa Raffaella Ferrè

    Full Text Available Vestibular signals are strongly integrated with information from several other sensory modalities. For example, vestibular stimulation was reported to improve tactile detection. However, this improvement could reflect either a multimodal interaction or an indirect interaction driven by vestibular effects on spatial attention and orienting. Here we investigate whether natural vestibular activation induced by passive whole-body rotation influences tactile detection. In particular, we assessed the ability to detect faint tactile stimuli to the fingertips of the left and right hand during spatially congruent or incongruent rotations. We found that passive whole-body rotations significantly enhanced sensitivity to faint shocks, without affecting response bias. Critically, this enhancement of somatosensory sensitivity did not depend on the spatial congruency between the direction of rotation and the hand stimulated. Thus, our results support a multimodal interaction, likely in brain areas receiving both vestibular and somatosensory signals.

  15. Animal physiology. Whole-body endothermy in a mesopelagic fish, the opah, Lampris guttatus.

    Science.gov (United States)

    Wegner, Nicholas C; Snodgrass, Owyn E; Dewar, Heidi; Hyde, John R

    2015-05-15

    Endothermy (the metabolic production and retention of heat to warm body temperature above ambient) enhances physiological function, and whole-body endothermy generally sets mammals and birds apart from other animals. Here, we describe a whole-body form of endothermy in a fish, the opah (Lampris guttatus), that produces heat through the constant "flapping" of wing-like pectoral fins and minimizes heat loss through a series of counter-current heat exchangers within its gills. Unlike other fish, opah distribute warmed blood throughout the body, including to the heart, enhancing physiological performance and buffering internal organ function while foraging in the cold, nutrient-rich waters below the ocean thermocline. Copyright © 2015, American Association for the Advancement of Science.

  16. Local forearm and whole-body respiratory quotient in humans after an oral glucose load

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, J

    1993-01-01

    The effects of an oral glucose load of 75 g on the local forearm and whole-body energy thermogenesis were measured in normal subjects during the 4 h after the glucose intake. Simultaneous assessment of substrate metabolism in the forearm was performed. Energy expenditure (EE) increased after...... the glucose load and had not returned to baseline level at the end of the experiment. Whole-body respiratory quotient (RQ) was, on average, 0.80 (SD 0.05) in the baseline condition and increased to a maximum of 0.91 (0.03) and then decreased to baseline level at the end of the experiment. The local forearm...... oxygen uptake increased 30 min after the glucose intake and remained elevated during the rest of the experiment. The carbon dioxide output from the forearm did not increase before 90 min after the glucose load. Consequently the local forearm RQ decreased significantly from a baseline value of 0.86 (0...

  17. The four-dimensional mouse whole-body phantoms and its application in medical imaging research

    International Nuclear Information System (INIS)

    Li Chongguo; Wu Dake

    2012-01-01

    Medical imaging simulation is a powerful tool for characterizing,evaluating,and optimizing medical imaging devices and techniques. A vital aspect of simulation is to have a realistic phantom or model of the subject's anatomy. Four-dimensional mouse whole-body phantoms provide realistic models of the mouse anatomy and physiology for imaging studies. When combined with accurate models for the imaging process,are capable of providing a wealth of realistic imaging data from subjects with various anatomies and motions (cardiac and respiratory) in health and disease. With this ability, the four-dimensional mouse whole-body phantoms have enormous potential to study the effects of anatomical, physiological and physical factors on medical and small animal imaging and to research new instrumentation, image acquisition strategies, image processing, reconstruction methods, image visualization and interpretation techniques. (authors)

  18. Computational anatomy based on whole body imaging basic principles of computer-assisted diagnosis and therapy

    CERN Document Server

    Masutani, Yoshitaka

    2017-01-01

    This book deals with computational anatomy, an emerging discipline recognized in medical science as a derivative of conventional anatomy. It is also a completely new research area on the boundaries of several sciences and technologies, such as medical imaging, computer vision, and applied mathematics. Computational Anatomy Based on Whole Body Imaging highlights the underlying principles, basic theories, and fundamental techniques in computational anatomy, which are derived from conventional anatomy, medical imaging, computer vision, and applied mathematics, in addition to various examples of applications in clinical data. The book will cover topics on the basics and applications of the new discipline. Drawing from areas in multidisciplinary fields, it provides comprehensive, integrated coverage of innovative approaches to computational anatomy. As well,Computational Anatomy Based on Whole Body Imaging serves as a valuable resource for researchers including graduate students in the field and a connection with ...

  19. Whole-body retention of 60Co incorporated into a seaweed in rats

    International Nuclear Information System (INIS)

    Inaba, Jiro; Nishimura, Yoshikazu; Ichikawa, Ryushi

    1979-01-01

    The objective of this study is to compare whole-body retention in the rat of radiocobalt incorporated into a marine green alga with that of 60 Co in inorganic form. Ulva pertusa was incubated in aerated seawater containing 60 Co under fluorescent lamp for 7 days. The radioactive seaweed was homogenated and was given to rats via a stomach tube. The control group of rats was given 60 CoCl 2 with homogenate of non-radioactive seaweed. Whole-body retention of the radionuclide was determined by in vivo counting of the living animal. The result revealed that rats absorbed and retained much more 60 Co incorporated into the seaweed than 60 CoCl 2 . This fact should be taken into account in the estimation of internal dose due to radiocobalt released into marine environment. (author)

  20. Effects of whole body UV-irradiation on oxygen delivery from the erythrocyte

    International Nuclear Information System (INIS)

    Humpeler, E.; Mairbaeurl, H.; Hoenigsmann, H.

    1982-01-01

    In 16 healthy caucasian volunteers (mean age: 22.2 years) the influence of whole body UV-irradiation on the oxygen transport properties of erythrocytes was investigated. Four hours after irradiation with UV (using the minimal erythema dose, MED) no variation of haemoglobin concentration, hematocrit, mean corpuscular haemoglobin concentration, pH or standard bicarbonate could be found, whereas inorganic plasma phosphate (Psub(i)), calcium, the intraerythrocytic 2,3-diphosphoglycerate (2,3-DPG), the activity of erythrocytic phosphofructokinase (PFK) and pyruvatekinase (PK) increased significantly. The half saturation tension of oxygen (P 50 -value) tended to increase. The increase of Psub(i) causes - via a stimulation of the glycolytic pathway - an increase in 2,3-DPG concentration and thus results in a shift of the oxygen dissociation curve. It is therefore possible to enhance tissue oxygenation by whole body UV-irradiation. (orig.)

  1. Development of an Ergonomics Checklist for Investigation of Work-Related Whole-Body Disorders in Farming - AWBA: Agricultural Whole-Body Assessment.

    Science.gov (United States)

    Kong, Y K; Lee, S J; Lee, K S; Kim, G R; Kim, D M

    2015-10-01

    Researchers have been using various ergonomic tools to study occupational musculoskeletal diseases in industrial contexts. However, in agricultural work, where the work environment is poorer and the socio-psychological stress is high due to the high labor intensities of the industry, current research efforts have been scarce, and the number of available tools is small. In our preliminary studies, which focused on a limited number of body parts and other working elements, we developed separate evaluation tools for the upper and lower extremities. The current study was conducted to develop a whole-body ergonomic assessment tool for agricultural work that integrates the existing assessment tools for lower and upper extremities developed in the preliminary studies and to verify the relevance of the integrated assessment tool. To verify the relevance of the Agricultural Whole-Body Assessment (AWBA) tool, we selected 50 different postures that occur frequently in agricultural work. Our results showed that the AWBA-determined risk levels were similar to the subjective risk levels determined by experts. In addition, as the risk level increased, the average risk level increased to a similar extent. Moreover, the differences in risk levels between the AWBA and expert assessments were mostly smaller than the differences in risk levels between other assessment tools and the expert assessments in this study. In conclusion, the AWBA tool developed in this study was demonstrated to be appropriate for use as a tool for assessing various postures commonly assumed in agricultural work. Moreover, we believe that our verification of the assessment tools will contribute to the enhancement of the quality of activities designed to prevent and control work-related musculoskeletal diseases in other industries.

  2. Whole-body MRI assessment of disease activity and structural damage in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Axelsen, Mette Bjørndal; Eshed, Iris; Duer, Anne

    2014-01-01

    Objective. The aim of this study was to investigate the ability of whole-body MRI (WBMRI) to visualize inflammation [synovitis, bone marrow oedema (BME) and enthesitis] and structural damage in patients with RA.Methods. The 3T WBMR images were acquired in a head-to-toe scan in 20 patients with RA...... tool for evaluation of the total inflammatory load of inflammation (an MRI joint count) and structural damage in RA patients....

  3. Eye - head coordination in the guinea pig I. Responses to passive whole body rotations

    OpenAIRE

    Shanidze, N.; Kim, A. H.; Raphael, Y.; King, W. M.

    2010-01-01

    Vestibular reflexes act to stabilize the head and eyes in space during locomotion. Head stability is essential for postural control whereas retinal image stability enhances visual acuity and may be essential for an animal to distinguish self-motion from that of an object in the environment. Guinea pig eye and head movements were measured during passive whole body rotation in order to assess the efficacy of vestibular reflexes. The vestibulo-ocular reflex (VOR) produced compensatory eye moveme...

  4. HKDC1 Is a Novel Hexokinase Involved in Whole-Body Glucose Use

    Science.gov (United States)

    Ludvik, Anton E.; Pusec, Carolina M.; Priyadarshini, Medha; Angueira, Anthony R.; Guo, Cong; Lo, Amy; Hershenhouse, Korri S.; Yang, Guang-Yu; Ding, Xianzhong; Reddy, Timothy E.; Lowe, William L.

    2016-01-01

    In a recent genome-wide association study, hexokinase domain-containing protein 1, or HKDC1, was found to be associated with gestational glucose levels during 2-hour glucose tolerance tests at 28 weeks of pregnancy. Because our understanding of the mediators of gestational glucose homeostasis is incomplete, we have generated the first transgenic mouse model to begin to understand the role of HKDC1 in whole-body glucose homeostasis. Interestingly, deletion of both HKDC1 alleles results in in utero embryonic lethality. Thus, in this study, we report the in vivo role of HKDC1 in whole-body glucose homeostasis using a heterozygous-deleted HKDC1 mouse model (HKDC1+/−) as compared with matched wild-type mice. First, we observed no weight, fasting or random glucose, or fasting insulin abnormalities with aging in male and female HKDC1+/− mice. However, during glucose tolerance tests, glucose levels were impaired in both female and male HKDC1+/− mice at 15, 30, and 120 minutes at a later age (28 wk of age). These glucose tolerance differences also existed in the female HKDC1+/− mice at earlier ages but only during pregnancy. And finally, the impaired glucose tolerance in HKDC1+/− mice was likely due to diminished whole-body glucose use, as indicated by the decreased hepatic energy storage and reduced peripheral tissue uptake of glucose in HKDC1+/− mice. Collectively, these data highlight that HKDC1 is needed to maintain whole-body glucose homeostasis during pregnancy but also with aging, possibly through its role in glucose use. PMID:27459389

  5. A shielding chamber for the Rossendorf whole-body counter; Eine Abschirmkammer fuer den Rossendorfer Ganzkoerperzaehler

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Stephan; Loehnert, Daniela [VKTA - Strahlenschutz, Analytik und Entsorgung Rossendorf e.V., Dresden (Germany).; Schreiber, Wolfgang [Ingenieurbedarf G. Schoene und W. Schreiber GmbH, Radeberg (Germany)

    2017-08-01

    A large part of radionuclides to be evaluated in the frame of incorporation monitoring are gamma emitter that can be directly measured (in vivo). In order to reach the required detection limits for the relevant radionuclides in the short measuring time high effort is necessary for the shielding of natural radioactivity. The contribution describes planning, construction and installation of the shielding chamber for the new in vivo whole body counter in Rossendorf. First experiences and preliminary results are discussed.

  6. Subjective evaluation of the effectiveness of whole-body cryotherapy in patients with osteoarthritis

    Directory of Open Access Journals (Sweden)

    Tomasz Chruściak

    2016-12-01

    Full Text Available Objectives: One of the treatments for osteoarthritis (OA is whole-body cryotherapy (WBC. The aim of this study is to assess the effect of whole-body cryotherapy on the clinical status of patients with osteoarthritis (OA, according to their subjective feelings before and after the application of a 10-day cold treatment cycle. The aim is also to assess the reduction of intensity and frequency of pain, the reduction of the painkiller medication used, and to assess the possible impact on physical activity. Material and methods : The study involved 50 people, including 30 women (60% and 20 men (40%. Thirty-one patients had spondyloarthritis (62% of respondents, 10 had knee osteoarthritis (20%, and 9 hip osteoarthritis (18%. The overall average age was 50.1 ±10.9 years; the youngest patient was 29 years old and the oldest 73 years old. The average age of the women was 6 years higher. The study used a questionnaire completed by patients, and consisted of three basic parts. The modified Laitinen pain questionnaire contained questions concerning the intensity and frequency of pain, frequency of painkiller use and the degree of limited mobility. The visual analogue scale (VAS was used in order to subjectively evaluate the therapy after applying the ten-day treatment cycle. Results: According to the subjective assessment of respondents, after the whole-body cryotherapy treatments, a significant improvement occurred in 39 patients (78%, an improvement in 9 patients (18%, and no improvement was only declared by 2 patients (4%. Conclusions : Whole-body cryotherapy resulted in a reduction in the frequency and degree of pain perception in patients with osteoarthritis. WBC reduced the number of analgesic medications in these patients. It improved the range of physical activity and had a positive effect on the well-being of patients.

  7. Neurogenic Effects of Low-Dose Whole-Body HZE (Fe) Ion and Gamma Irradiation.

    Science.gov (United States)

    Sweet, Tara B; Hurley, Sean D; Wu, Michael D; Olschowka, John A; Williams, Jacqueline P; O'Banion, M Kerry

    2016-12-01

    Understanding the dose-toxicity profile of radiation is critical when evaluating potential health risks associated with natural and man-made sources in our environment. The purpose of this study was to evaluate the effects of low-dose whole-body high-energy charged (HZE) iron (Fe) ions and low-energy gamma exposure on proliferation and differentiation of adult-born neurons within the dentate gyrus of the hippocampus, cells deemed to play a critical role in memory regulation. To determine the dose-response characteristics of the brain to whole-body Fe-ion vs. gamma-radiation exposure, C57BL/6J mice were irradiated with 1 GeV/n Fe ions or a static 137 Cs source (0.662 MeV) at doses ranging from 0 to 300 cGy. The neurogenesis was analyzed at 48 h and one month postirradiation. These experiments revealed that whole-body exposure to either Fe ions or gamma radiation leads to: 1. An acute decrease in cell division within the dentate gyrus of the hippocampus, detected at doses as low as 30 and 100 cGy for Fe ions and gamma radiation, respectively; and 2. A reduction in newly differentiated neurons (DCX immunoreactivity) at one month postirradiation, with significant decreases detected at doses as low as 100 cGy for both Fe ions and gamma rays. The data presented here contribute to our understanding of brain responses to whole-body Fe ions and gamma rays and may help inform health-risk evaluations related to systemic exposure during a medical or radiologic/nuclear event or as a result of prolonged space travel.

  8. Mechanisms of taurine hyperexcretion after whole-body irradiation of rats

    International Nuclear Information System (INIS)

    Beskrovnaya, L.A.; Lapteva, T.A.; Dokshina, G.A.; Baranova, M.I.

    1976-01-01

    Mechanisms of postirradiation hyperexcretion of taurine with urine have been investigated. In the course of three days after a whole-body exposure of rats (700 rads), the excretion of taurine increases. The experiments in vitro have demonstrated that taurine synthesis decreases in the thymus and liver of irradiated animals. The experiments conducted have shown that the postirradiation hyperexcretion of taurine is partly due to its release from the lymohoid tissue (thymus)

  9. Whole body perfusion in patients undergoing frozen elephant trunk for type A acute aortic dissections.

    Science.gov (United States)

    Cappabianca, Giangiuseppe; Roscitano, Claudio; Bichi, Samuele; Cricco, Antonio; Parrinello, Matteo; Beghi, Cesare; Albano, Giovanni; Esposito, Giampiero

    2017-03-01

    The Frozen Elephant Trunk (FET) can be adopted in selected type A acute aortic dissections (TAAAD). During FET, a prolonged distal circulatory arrest exposes the spine and visceral organs to potential ischemic injuries. Antegrade distal aortic perfusion (ADAP) could minimize this risk: we describe the technical aspects of the simultaneous use of antegrade cerebral perfusion (ACP) and ADAP achieving a "Whole Body Perfusion" (WBP) during FET.

  10. Effects of whole-body gamma irradiation on oxygen transport by rat erythrocytes

    International Nuclear Information System (INIS)

    Thiriot, Christian; Kergonou, J.F.; Rocquet, Guy; Allary, Michel; Saint-Blancard, Jacques

    1982-01-01

    In this work, we studied the influence of whole-body gamma irradiation (8 Gy) upon oxygen transport by erythrocytes, through the erythrocyte count and related parameters, and through the factors affecting the oxygen affinity of hemoglobin. The oxygen affinity of hemoglobin is increased from day D + 5 after irradiation, and a severe erythropenia develops from day D + 8. These modifications probably result in tissue hypoxia via diminished oxygen transport from lungs to tissues, and decreased oxygen release from oxyhemoglobin in tissues

  11. Whole body massage for reducing anxiety and stabilizing vital signs of patients in cardiac care unit

    OpenAIRE

    Adib-Hajbaghery, Mohsen; Abasi, Ali; Rajabi-Beheshtabad, Rahman

    2014-01-01

    Background: Patients admitted in coronary care units face various stressors. Ambiguity of future life conditions and unawareness of caring methods intensifies the patients’ anxiety and stress. This study was conducted to assess the effects of whole body massage on anxiety and vital signs of patients with acute coronary disorders. Methods: A randomized controlled trial was conducted on 120 patients. Patients were randomly allocated into two groups. The intervention group received a session of ...

  12. Endurance exercise training blunts the deleterious effect of high-fat feeding on whole body efficiency

    Science.gov (United States)

    Holloway, Cameron J.; Murray, Andrew J.; Knight, Nicholas S.; Carter, Emma E.; Kemp, Graham J.; Thompson, Campbell H.; Tyler, Damian J.; Neubauer, Stefan; Robbins, Peter A.; Clarke, Kieran

    2011-01-01

    We recently showed that a week-long, high-fat diet reduced whole body exercise efficiency in sedentary men by >10% (Edwards LM, Murray AJ, Holloway CJ, Carter EE, Kemp GJ, Codreanu I, Brooker H, Tyler DJ, Robbins PA, Clarke K. FASEB J 25: 1088–1096, 2011). To test if a similar dietary regime would blunt whole body efficiency in endurance-trained men and, as a consequence, hinder aerobic exercise performance, 16 endurance-trained men were given a short-term, high-fat (70% kcal from fat) and a moderate carbohydrate (50% kcal from carbohydrate) diet, in random order. Efficiency was assessed during a standardized exercise task on a cycle ergometer, with aerobic performance assessed during a 1-h time trial and mitochondrial function later measured using 31P-magnetic resonance spectroscopy. The subjects then underwent a 2-wk wash-out period, before the study was repeated with the diets crossed over. Muscle biopsies, for mitochondrial protein analysis, were taken at the start of the study and on the 5th day of each diet. Plasma fatty acids were 60% higher on the high-fat diet compared with moderate carbohydrate diet (P < 0.05). However, there was no change in whole body efficiency and no change in mitochondrial function. Endurance exercise performance was significantly reduced (P < 0.01), most probably due to glycogen depletion. Neither diet led to changes in citrate synthase, ATP synthase, or mitochondrial uncoupling protein 3. We conclude that prior exercise training blunts the deleterious effect of short-term, high-fat feeding on whole body efficiency. PMID:21632846

  13. Cereal fiber improves whole-body insulin sensitivity in overweight and obese women.

    Science.gov (United States)

    Weickert, Martin O; Möhlig, Matthias; Schöfl, Christof; Arafat, Ayman M; Otto, Bärbel; Viehoff, Hannah; Koebnick, Corinna; Kohl, Angela; Spranger, Joachim; Pfeiffer, Andreas F H

    2006-04-01

    Cereal fiber intake is linked to reduced risk of type 2 diabetes in epidemiological observations. The pathogenic background of this phenomenon is unknown. Based on recent findings, we hypothesized that intake of purified insoluble oat fiber may improve whole-body insulin sensitivity. A randomized, controlled, single-blind, cross-over study was performed, and 17 overweight or obese subjects with normal glucose metabolism were analyzed. After consumption of nine macronutrient-matched portions of fiber-enriched bread (white bread enriched with 31.2 g insoluble fiber/day) or control (white bread) over a time period of 72 h, whole-body insulin sensitivity was assessed by euglycemic-hyperinsulinemic clamp. Energy intake was individually adjusted by providing standardized liquid meals. Hydrogen breath tests were performed to control for dietary adherence. When analyzing the entire cohort, whole-body glucose disposal was improved after fiber consumption (M value 6.56 +/- 0.32 vs. 6.07 +/- 0.27 mg . min(-1) . kg(-1); P = 0.043). Thirteen subjects had increased hydrogen breath test concentrations after fiber consumption, indicating probable dietary adherence. Restricting analysis to these subjects, improvements in M value (6.85 +/- 0.34 vs. 6.06 +/- 0.32 mg . min(-1) . kg(-1); P = 0.003) and insulin sensitivity, expressed as M/I ratio (M value divided by mean serum insulin at steady state: 3.73 +/- 0.23 vs. 3.21 +/- 0.27; P = 0.02), after fiber consumption were more pronounced. Plasma lipids, serum magnesium, ghrelin, and adiponectin concentrations, as well as substrate utilization and body weight, were not significantly changed by fiber intake (P > 0.15). Increased insoluble dietary fiber intake for 3 days significantly improved whole-body insulin sensitivity. These data suggest a potential mechanism linking cereal fiber intake and reduced risk of type 2 diabetes.

  14. Whole-Body Vibrations Associated With Alpine Skiing: A Risk Factor for Low Back Pain?

    Directory of Open Access Journals (Sweden)

    Matej Supej

    2018-03-01

    Full Text Available Alpine skiing, both recreational and competitive, is associated with high rates of injury. Numerous studies have shown that occupational exposure to whole-body vibrations is strongly related to lower back pain and some suggest that, in particular, vibrations of lower frequencies could lead to overuse injuries of the back in connection with alpine ski racing. However, it is not yet known which forms of skiing involve stronger vibrations and whether these exceed safety thresholds set by existing standards and directives. Therefore, this study was designed to examine whole-body vibrations connected with different types of skiing and the associated potential risk of developing low back pain. Eight highly skilled ski instructors, all former competitive ski racers and equipped with five accelerometers and a Global Satellite Navigation System to measure vibrations and speed, respectively, performed six different forms of skiing: straight running, plowing, snow-plow swinging, basic swinging, short swinging, and carved turns. To estimate exposure to periodic, random and transient vibrations the power spectrum density (PSD and standard ISO 2631-1:1997 parameters [i.e., the weighted root-mean-square acceleration (RMS, crest factor, maximum transient vibration value and the fourth-power vibration dose value (VDV] were calculated. Ground reaction forces were estimated from data provided by accelerometers attached to the pelvis. The major novel findings were that all of the forms of skiing tested produced whole-body vibrations, with highest PSD values of 1.5–8 Hz. Intensified PSD between 8.5 and 35 Hz was observed only when skidding was involved. The RMS values for 10 min of short swinging or carved turns, as well as all 10-min equivalent VDV values exceeded the limits set by European Directive 2002/44/EC for health and safety. Thus, whole-body vibrations, particularly in connection with high ground reaction forces, contribute to a high risk for low back

  15. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    International Nuclear Information System (INIS)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P.

    2000-01-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10 -2 seems possible in the near future. (author)

  16. Whole body measurements of subjects who have ingested radioactive materials from the accident at Chernobyl

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1987-01-01

    Iodine-131 in the thyroid was the most significant nuclide that was detected in subjects monitored by the Australian Radiation Laboratory who might have been exposed by the Chernobyl nuclear accident. The estimated intake of I-131 by subjects ranged from 0.4 to 12 kBq, with a weighted committed dose equivalent (thyroid) of between 0.006 and 0.17 mSv. Whole-body monitoring data is presented for all subjects

  17. Changes in serum 25-hydroxyvitamin D and cholecalciferol after one whole-body exposure in a commercial tanning bed

    DEFF Research Database (Denmark)

    Langdahl, Jacob H; Schierbeck, Louise Lind; Bang, Ulrich Christian

    2012-01-01

    We wanted to evaluate the cutaneous synthesis of 25OHD and cholecalciferol after one whole-body exposure to ultraviolet radiation type B (UVB) in a randomized setup. Healthy volunteers were randomized to one whole-body exposure in a commercial tanning bed with UVB emission (UVB/UVA ratio 1...

  18. Small and inconsistent effects of whole body vibration on athletic performance : a systematic review and meta-analysis

    NARCIS (Netherlands)

    Hortobagyi, Tibor; Lesinski, Melanie; Fernandez-del-Olmo, Miguel; Granacher, Urs

    We quantified the acute and chronic effects of whole body vibration on athletic performance or its proxy measures in competitive and/or elite athletes. Systematic literature review and meta-analysis. Whole body vibration combined with exercise had an overall 0.3 % acute effect on maximal voluntary

  19. [Intraindividual comparison of whole body cold therapy and warm treatment with hot packs in generalized tendomyopathy].

    Science.gov (United States)

    Samborski, W; Stratz, T; Sobieska, M; Mennet, P; Müller, W; Schulte-Mönting, J

    1992-01-01

    In a cross-over study, the short-term efficacy of whole-body cold therapy and hot mud packs in patients with generalized tendomyopathy (fibromyalgia) was compared. As a pain assessment, visual analog scale and so-called pain score were measured; dolorimetry of the 24 tender points and eight control points was performed as well. Using these methods, we found that there is a significant improvement of all parameters examined during a 2-h period of measurements after cold application, and a marked improvement was also detectable 24 h after this therapy. In contrast, only pain score values showed a slight decrease immediately after hot mud-pack therapy, and no significant differences were found in visual analog scale and pressure tenderness as measured dolorimetrically. Central inhibition of nociceptors as a result of an activation of A-delta system as well as a blockade of gamma-motoneurons are discussed to be a mechanism of action of whole-body cold therapy, resulting in a decrease in muscle tonus. Long-term studies are needed to determine, if there is any enduring effect of whole-body cold therapy on pain in the patients with generalized tendomyopathy.

  20. Effects of whole-body irradiation on neonatally thymectomized mice. Incidence of benign and malignant tumors

    International Nuclear Information System (INIS)

    Anderson, R.E.; Howarth, J.L.; Troup, G.M.

    1978-01-01

    The individual and combined effects of neonatal thymectomy and whole-body irradiation on the prevalence of benign and malignant tumors in germ-free female mice of the Charles Rivers line were studied to determine if a portion of the tumorigenic effects of irradiation can be attributed to injury of the thymic-dependent component of the immune response. Neonatal thymectomy increased (a) the incidence of benign and malignant tumors and (b) the prevalence of multiple primary neoplasms in an individual mouse. Whole-body exposure to 700 rad at 6 weeks of age further increased the incidence of tumors, but the relative magnitude of this increase was less pronounced than in sham-operated controls. Thus, the cumulative effects of thymectomy plus irradiation are less pronounced than the sum of the individual effects. One of several possible explanations for this observation is that a portion of the carcinogenic effects of whole-body irradiation is mediated by suppression of the thymic-dependent component of the immune response

  1. Wireless Cortical Brain-Machine Interface for Whole-Body Navigation in Primates

    Science.gov (United States)

    Rajangam, Sankaranarayani; Tseng, Po-He; Yin, Allen; Lehew, Gary; Schwarz, David; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2016-03-01

    Several groups have developed brain-machine-interfaces (BMIs) that allow primates to use cortical activity to control artificial limbs. Yet, it remains unknown whether cortical ensembles could represent the kinematics of whole-body navigation and be used to operate a BMI that moves a wheelchair continuously in space. Here we show that rhesus monkeys can learn to navigate a robotic wheelchair, using their cortical activity as the main control signal. Two monkeys were chronically implanted with multichannel microelectrode arrays that allowed wireless recordings from ensembles of premotor and sensorimotor cortical neurons. Initially, while monkeys remained seated in the robotic wheelchair, passive navigation was employed to train a linear decoder to extract 2D wheelchair kinematics from cortical activity. Next, monkeys employed the wireless BMI to translate their cortical activity into the robotic wheelchair’s translational and rotational velocities. Over time, monkeys improved their ability to navigate the wheelchair toward the location of a grape reward. The navigation was enacted by populations of cortical neurons tuned to whole-body displacement. During practice with the apparatus, we also noticed the presence of a cortical representation of the distance to reward location. These results demonstrate that intracranial BMIs could restore whole-body mobility to severely paralyzed patients in the future.

  2. Clinical evaluation of exercise thallium-201 whole body scintigraphy in ischemic heart disease

    International Nuclear Information System (INIS)

    Kaneko, Kenzo; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    To evaluate whole body distribution and kinetics of Thallium-201 at exercise and redistribution, whole body scintigraphy (WB-S) was performed on 12 normal subjects (N), 19 patients with angina pectoris (AP) and 18 patients with old myocardial infarction (MI). WB-S was obtained using a gamma camera OMEGA 500 and analized by ADAC System IV. We estimated the following parameters from WB-S; 1) %Distribution (%D): the ratio of whole body counts to organ counts 2) washout rate (WR) in each organ. %D of the heart in N, AP and MI was similar at rest and exercise. At exercise, %D of the lung and the liver decreased and %D of thighs increased remarkably than at rest. At supine exercise, the lung indicated high %D and thinghs indicated low %D compared with at upright exercise. WR of the heart in AP and MI was significantly lower than in N (p<0.005, p<0.01) and further decreased proportionally to the number of stenotic coronary arteries and related to the ischemic ST depression of exercise ECG. WR of the heart was not correlation with pressure rate product and this finding suggested that WR of the heart was not prescribed by the tolerance of exercise but related to coronary flow at exercise a certain degree. WR of the lung in MI was significantly higher (p<0.025) and WR of thighs in AP and MI was significantly lower (p<0.025, p<0.05) compared with N. (author)

  3. Effective dose estimation in whole-body multislice CT in paediatric trauma patients

    International Nuclear Information System (INIS)

    Munk, Robin D.; Saueressig, Ulrich; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A.; Strohm, Peter C.; Zwingmann, Joern; Suedkamp, Norbert P.; Uhl, Markus

    2009-01-01

    The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD±7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with relevant information to initiate life-saving therapy. Radiologists should use special paediatric protocols that include dose-saving mechanisms to keep the effective dose as low as possible. Further studies are needed to examine and advance dose-saving strategies in MSCT, especially in children. (orig.)

  4. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-l-tyrosine

    International Nuclear Information System (INIS)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Tellmann, Lutz; Langen, Karl-J.; Hamacher, Kurt; Coenen, Heinz H.; Mueller, Hans-W.

    2003-01-01

    The whole-body distribution of O-(2-[ 18 F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV ≤1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 μSv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  5. Whole-body distribution and dosimetry of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine

    Energy Technology Data Exchange (ETDEWEB)

    Pauleit, Dirk [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Clinic of Nuclear Medicine, Research Center Juelich, P.O. Box 1913, 52425, Juelich (Germany); Floeth, Frank [Department of Neurosurgery, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany); Herzog, Hans; Tellmann, Lutz; Langen, Karl-J. [Institute of Medicine, Research Center Juelich, Juelich (Germany); Hamacher, Kurt; Coenen, Heinz H. [Institute of Nuclear Chemistry, Research Center Juelich, Juelich (Germany); Mueller, Hans-W. [Clinic of Nuclear Medicine, Heinrich-Heine-University Duesseldorf, Duesseldorf (Germany)

    2003-04-01

    The whole-body distribution of O-(2-[{sup 18}F]fluoroethyl)-l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV {<=}1.6) which remained constant between early and late PET scans. No increased uptake was seen in the bone, the biliary tract or the pancreas. Twenty-two percent of the injected activity was excreted 5 h p.i. (approx. 5.3% ID/h). The highest absorbed dose was found for the urinary bladder wall. The effective dose according to ICRP 60 was 16.5 {mu}Sv/MBq for adults, which would lead to an effective dose of 6.1 mSv in a PET study using 370 MBq FET. (orig.)

  6. Whole-body distribution and dosimetry of O-(2-[18F]fluoroethyl)-L-tyrosine.

    Science.gov (United States)

    Pauleit, Dirk; Floeth, Frank; Herzog, Hans; Hamacher, Kurt; Tellmann, Lutz; Müller, Hans-W; Coenen, Heinz H; Langen, Karl-J

    2003-04-01

    The whole-body distribution of O-(2-[(18)F]fluoroethyl)- l-tyrosine (FET) was studied in seven patients with brain tumours by positron emission tomography (PET). Based on the IMEDOSE and MIRDOSE procedures, radiation absorbed doses were estimated from whole-body PET scans acquired approximately 70 and 200 min after i.v. injection of 400 MBq FET. After injection of FET, the peak of radioactivity in the blood was observed after 1.5 min, and a plateau of nearly constant radioactivity was reached at 20 min. The whole-body distribution of FET showed the highest activities in the urinary tract. All other organs exhibited only moderate FET uptake (SUV

  7. An experimental test on large animals of MCNP application for whole body counting

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V. [State Research Center, Institute of Biophysics, Moscow (Russian Federation); Tsedish, S.; Tyurin, I. [Clinical Hospital No. 6 of Federal Medico-Biological Agency, Moscow (Russian Federation); Franck, D.; Carlan, L. de [Institut de Radioprotection et de Surete Nucleaire, 92 - Fontenay-aux Roses (France)

    2005-07-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of {gamma}-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. {sup 241}Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy {gamma}-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for {sup 241}Am administered via injection and less than 10% for {sup 241}Am administered inside the capsules. (authors)

  8. Whole body organization during a symmetric bimanual pick up task in overweight and obese children.

    Science.gov (United States)

    Hung, Ya-Ching; Mangiafreno, Melissa; Gill, Simone V

    2017-02-01

    Information on the effects of obesity on the biomechanics of whole body movement control in children is limited. The purpose of the current study is to test the hypothesis that during a simple pick up task, overweight and obese children will organize their whole body movements differently than those in normal weight children. Twelve children who were overweight or obese (5-13 years old) and twelve age matched normal weight children participated in the study. Children picked up an empty box to waist height at a self-selected pace while kinematic and kinetic data were recorded and analyzed using a VICON system and two AMTI force plates. The overweight and obese group showed less knee flexion in both legs, more spine flexion, and less excursion in the height of their center of mass (all Psoverweight and obese group had more anterior movement in their center of mass (Poverweight and obese group had greater anterior excursion with faster average anterior moving speed and spent a longer time with the center of pressure reached forward (all Psoverweight and obese children organize their whole body movement during a simple pick up task differently with higher and more forward center of mass, quickly shifting their center of pressure anteriorly, and with a longer period of time with the center of pressure remaining forward. Their movement strategy may put them in a less stable condition and thus make them prone to losing balance. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Whole-body magnetic resonance imaging in children: state of the art

    Directory of Open Access Journals (Sweden)

    Sara Reis Teixeira

    2015-04-01

    Full Text Available Whole-body imaging in children was classically performed with radiography, positron-emission tomography, either combined or not with computed tomography, the latter with the disadvantage of exposure to ionizing radiation. Whole-body magnetic resonance imaging (MRI, in association with the recently developed metabolic and functional techniques such as diffusion-weighted imaging, has brought the advantage of a comprehensive evaluation of pediatric patients without the risks inherent to ionizing radiation usually present in other conventional imaging methods. It is a rapid and sensitive method, particularly in pediatrics, for detecting and monitoring multifocal lesions in the body as a whole. In pediatrics, it is utilized for both oncologic and non-oncologic indications such as screening and diagnosis of tumors in patients with genetic syndromes, evaluation of disease extent and staging, evaluation of therapeutic response and post-therapy follow-up, evaluation of non neoplastic diseases such as multifocal osteomyelitis, vascular malformations and syndromes affecting multiple regions of the body. The present review was aimed at describing the major indications of whole-body MRI in pediatrics added of technical considerations.

  10. Involvement patterns in myotilinopathy and desminopathy detected by a novel neuromuscular whole-body MRI protocol

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, Nicolai; Born, Christine; Weckbach, Sabine; Reiser, Maximilian F. [Ludwig-Maximilians-University, Institute for Clinical Radiology, Munich (Germany); Reilich, Peter; Walter, Maggie C. [Ludwig-Maximilians-University, Friedrich-Baur-Institute, Department of Neurology, Munich (Germany)

    2008-12-15

    Whole-body MRI (WB-MRI) has been successfully applied for oncologic and cardiovascular diagnostics, whereas imaging in myopathies usually employs dedicated protocols restricted to areas of specific interest. In this study, we propose a comprehensive neuromuscular WB-MRI protocol. Eighteen patients with degenerative and inflammatory muscle diseases were included. Whole-body imaging was performed on a 1.5-T MR system using parallel imaging. Examination time was 41:26 min. Coronal and axial T1-weighted and coronal short tau inversion recovery (STIR) sequences of the whole body were acquired. Images were analysed by two radiologists. With this protocol we could detect characteristic involvement patterns in different myofibrillar myopathies (MFMs): Patients with myotilinopathy showed frequent involvement of the rhomboid muscles (4/5), the erector spinae (5/5), the biceps femoris and the semimembranosus (5/5), while the semitendinosus was relatively spared (2/5). In contrast, in desminopathy patients the ilipsoas (3/4), the sartorius, (3/4), the gracilis (3/4) and the semitendinosus (3/4) were frequently involved, while the semimembranosus was spared (1/4). As shown for MFMs, WB-MRI is an appropriate modality to detect fatty infiltration and oedema in skeletal muscles. WB-MRI could be more useful than dedicated examinations for differential diagnosis, muscle biopsy planning and noninvasive follow-up examinations. (orig.)

  11. Involvement patterns in myotilinopathy and desminopathy detected by a novel neuromuscular whole-body MRI protocol

    International Nuclear Information System (INIS)

    Schramm, Nicolai; Born, Christine; Weckbach, Sabine; Reiser, Maximilian F.; Reilich, Peter; Walter, Maggie C.

    2008-01-01

    Whole-body MRI (WB-MRI) has been successfully applied for oncologic and cardiovascular diagnostics, whereas imaging in myopathies usually employs dedicated protocols restricted to areas of specific interest. In this study, we propose a comprehensive neuromuscular WB-MRI protocol. Eighteen patients with degenerative and inflammatory muscle diseases were included. Whole-body imaging was performed on a 1.5-T MR system using parallel imaging. Examination time was 41:26 min. Coronal and axial T1-weighted and coronal short tau inversion recovery (STIR) sequences of the whole body were acquired. Images were analysed by two radiologists. With this protocol we could detect characteristic involvement patterns in different myofibrillar myopathies (MFMs): Patients with myotilinopathy showed frequent involvement of the rhomboid muscles (4/5), the erector spinae (5/5), the biceps femoris and the semimembranosus (5/5), while the semitendinosus was relatively spared (2/5). In contrast, in desminopathy patients the ilipsoas (3/4), the sartorius, (3/4), the gracilis (3/4) and the semitendinosus (3/4) were frequently involved, while the semimembranosus was spared (1/4). As shown for MFMs, WB-MRI is an appropriate modality to detect fatty infiltration and oedema in skeletal muscles. WB-MRI could be more useful than dedicated examinations for differential diagnosis, muscle biopsy planning and noninvasive follow-up examinations. (orig.)

  12. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  13. [Muscular disorders associated with ankylosing spondylitis and their correction with the help of whole body cryotherapy].

    Science.gov (United States)

    Kulikov, A G; Tabiev, V I; Rassulova, M A

    2015-01-01

    The objective of the present study was to evaluate the possibilities for the correction of muscular disorders associated with ankylosing spondylitis and their correction with the help of whole body cryotherapy. The study included 55 patients randomly allocated to two groups. Group 1 was comprised of the patients treated with the use of the common mineral baths, physiotherapy, therapeutic physical exercises, spinal massage, and whole body air-cryotherapy. Group 2 contained the patients who were treated in a similar way with the exception of whole body cryotherapy; they served as controls. Muscular disorders were diagnosed by means of functional muscular testing. The study has demonstrated the high prevalence of muscular disorders in the patients suffering from ankylosing spondylitis. Moreover, it revealed the profile of such disorders associated with ankylosing spondylitis and showed significant correlation between the results of functional muscular testing, BASMI and BASFI indices as well as characteristics of chest excursions (pcryotherapy in comparison with the alternative therapeutic modalities employed in the present study. This therapeutic modality ensured the statistically more pronounced improvement of functional muscular testing parameters (pcryotherapy accounting for its corrective influence on the muscular disorders in the patients presenting with ankylosing spondylitis. It is concluded that the proposed approach can be recommended for the introduction in the combined therapeutic and rehabilitative treatment of muscular disorders associated with ankylosing spondylitis.

  14. Whole Body Microwave Irradiation for Improved Dacarbazine Therapeutical Action in Cutaneous Melanoma Mouse Model

    Directory of Open Access Journals (Sweden)

    Monica Neagu

    2013-01-01

    Full Text Available A cutaneous melanoma mouse model was used to test the efficacy of a new therapeutical approach that uses low doses of cytostatics in conjunction with mild whole body microwave exposure of 2.45 GHz in order to enhance cytostatics antitumoral effect. Materials and Methods. A microwave exposure system for C57BL/6 mouse whole body microwave irradiation was designed; groups of 40 mice (males and females bearing experimental tumours were subjected to a combined therapy comprising low doses of dacarbazine in combination with mild whole body irradiation. Clinical parameters and serum cytokine testing using xMAP technology were performed. Results. The group that was subjected to combined therapy, microwave and cytostatic, had the best clinical evolution in terms of overall survival, tumour volume, and metastatic potential. At day 14 the untreated group had 100% mortality, while in the combined therapy group 40% of mice were surviving. Quantifying serum IL-1β, IL-6, IL-10, IL-12 (p70, IFN-γ, GM-CSF, TNF-α, MIP-1α, MCP-1, and KC during tumorigenesis and therapy found that the combined experimental therapy decreases all the inflammatory cytokines, except chemokine MCP-1 that was found increased, suggesting an increase of the anti-tumoral immune response triggered by the combined therapy. The overall metastatic process is decreased in the combined therapy group.

  15. Decreased tumor uptake of gallium-67 in animals after whole-body irradiation. [Gamma radiation, rats

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, W.P.; Alderson, P.O.; Eckelman, W.C.; Hamilton, R.G.; Weiss, J.F.

    1978-02-01

    The mechanism of decreased Ga-67 citrate retention and serum binding after whole-body irradiation is unknown. To investigate this mechanism and to determine the effects of prior irradiation on tumor uptake of Ga-67, Sprague-Dawley rats bearing a subcutaneous Walker-256 carcinosarcoma were exposed to whole-body Co-60 irradiations of 250-1000 rads. Each animal received 10 ..mu..Ci of Ga-67 citrate intravenously 24 hr after exposure. Control animals received Ga-67 but were not irradiated. Animals were killed at 48 hr and the uptakes (percentage ID/g) in the tumor and other tissues were determined. A blood sample was also obtained to determine the serum iron, unsaturated iron-binding capacity (UIBC) and transferrin level. Tumor uptake and serum UIBC were decreased in irradiated animals, whereas serum iron levels and Ga-67 urinary excretion were increased. There was a significant correlation between the UIBC and the Ga-67 tumor uptake (r = 0.78, p < 0.001, n = 49). Transferrin levels in the irradiated group were not different from control values. The results indicate that the decreased Ga-67 retention and tumor uptake seen after whole-body irradiation are related--at least in part--to the saturation of transferrin by increased levels of circulating iron.

  16. Calibration of CDTN-whole body counter for in vivo measurements of I-131

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Silva, Tania V. da; Alonso, Thessa C.; Squair, Peterson L.

    2009-01-01

    Iodine-131 is frequently used in nuclear medicine services for diagnosis and therapy of thyroid diseases. Furthermore, the Nuclear Technology Development Centre (CDTN/CNEN), in Belo Horizonte, uses Iodine-131 for radiobiology and radiopharmacy researches. The increasing use of this radionuclide for medical and research purposes as well as its high volatility creates a demand for feasible methodologies to perform occupational control of internal contamination. Therefore the objective this work is to develop methods of in vivo bioassay for evaluation Iodine-131 incorporation by using NaI(Tl) 6'' x 4'' scintillation detector of the CDTN-Whole Body Counter (WBC). Such detector was calibrated for in vivo measurements with a neck-thyroid phantom, simulating Iodine-131 incorporation. The chosen counting geometry was lying under monitoring bed of CDTNWBC. A methodology for bioassay data interpretation, based on standard ICRP 56 model was established with software AIDE (activity internal dose estimate) version 6.0. It was concluded that in vivo measurements have sufficient sensitivity for the monitoring of Iodine-131 through CDTN-Whole Body Counter. Therefore, the CDTN-Whole Body Counter equipment of Belo Horizonte are ready to attend suspicion intake cases of Iodine- 131 (author)

  17. Kidney, lower limb and whole-body uptake and release of catecholamines in alcoholic liver disease

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Ring-Larsen, H; Christensen, N J

    1988-01-01

    Regional (kidney, lower limb) and whole-body kinetics of endogenous noradrenaline (NA) and tritium-labelled L-noradrenaline (3H-NA) were determined in patients with alcoholic liver disease (one alcoholic hepatitis, 12 cirrhosis) and in control subjects (n = 6) in order to get information on the s......Regional (kidney, lower limb) and whole-body kinetics of endogenous noradrenaline (NA) and tritium-labelled L-noradrenaline (3H-NA) were determined in patients with alcoholic liver disease (one alcoholic hepatitis, 12 cirrhosis) and in control subjects (n = 6) in order to get information...... to controls and non-ascitic patients (1.2 and 1.0 pmol/min.g, respectively. Patients and control kidneys and limbs extracted almost the same fraction of 3H-NA (0.34 vs. 0.32 NS and 0.34 vs. 0.37 NS, respectively). Whole-body clearance of 3H-NA was not significantly different in cirrhotics and controls (median...... 0.89 vs. 0.91 l/min.m2), indicating that the raised NA in decompensated cirrhosis reflects enhanced sympatho-adrenal activity rather than decreased metabolism of this amine. Our results do not point towards a uniform sympatho-adrenal overactivity in decompensated cirrhosis, but rather indicate...

  18. In-vivo whole body measurement of internal radioactivity in the Nordic countries

    Energy Technology Data Exchange (ETDEWEB)

    Risco Norrlid, L. del (Swedish Radiation Safety Authority (Sweden)); Halldorsson, O. (Icelandic Radiation Safety Authority (Iceland)); Holm, S. (NM and PET at Copenhagen' s Univ. Hospital (Denmark)); Huikari, J. (Radiation and Nuclear Safety Authority (Finland)); Isaksson, M. (Goeteborg Univ., Dept. Radiation Physics Sahlgren Academy (Sweden)); Lind, B. (Norwegian Radiation Protection Authority (Norway)); Roed, H. (Danish State Institute for Radiation Protection (Denmark))

    2011-02-15

    The PIANOLIB activity aims to harmonize the calibrations of the measurement equipment in the region and to evaluate the quality status of this kind of measurement by means of a proficiency test exercise. In this report the first results of the PIANOLIB activity are presented, that is, a compilation of existent regional resources for in-vivo whole body measurement and the phantom library website. In 2010 the project PIANOLIB collected the relevant information about the regional facilities, distributed the exercise instructions and managed the circulation of the phantom IRINA among the participant laboratories. The inventory within the activity has showed that the regional whole body counting assets has relatively diminished compared to 2006, the last time an inventory of the kind was made. Both the field laboratories as the stationary ones are equipped with sophisticated whole-body counting systems with Ge-or NaI-detectors. The regional competence is good and still retains experienced staff, but it is clear that a new generation is coming that needs training and exchange of experiences. It is important to keep the practice of intercomparison and NKS continues to be the best framework for supporting this kind of activity. (Author)

  19. Importance of Intercomparison Exercises in Assessment of Internal Exposure by Whole-Body Counter

    International Nuclear Information System (INIS)

    Andrasi, A.

    2001-01-01

    Full text: Basic requirement for any kind of measurement is to check and prove the reliability and correctness of the measured results. Quality assurance programmes require several activities among which the participation in intercomparison exercises plays an important role. Since the determination of radioactive materials in the human body by whole-body counting technique implies many sources of uncertainties the reliability of calibration data and consequently the measured results have to be checked by participation in intercomparison quality control programmes. In these programmes mostly different kinds of phantoms simulating the human body are circulated among the participating laboratories, however sometimes contaminated persons are also subjects of intercomparison measurements. There are guidelines in several countries laid down concerning the requirements of whole-body counter measurements where the performance criteria for the relative bias, precision and minimum detectable amounts are formulated. These quantities are mostly the subject of intercomparison programmes. The whole body counter laboratory of the KFKI Atomic Energy Research Institute participated in intercomparison exercises several times in the last few years. The lessons learned during these activities helped in checking the capabilities of applied methods and measuring geometry as well as contributed in improving the accuracy of the measured results. A short overview on the previous international intercomparison exercises their main characteristics the results obtained and conclusions drawn are discussed in the paper with special attention to those in which also our laboratory participated. (author)

  20. An experimental test on large animals of MCNP application for whole body counting

    International Nuclear Information System (INIS)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V.; Tsedish, S.; Tyurin, I.; Franck, D.; Carlan, L. de

    2005-01-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of γ-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. 241 Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy γ-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for 241 Am administered via injection and less than 10% for 241 Am administered inside the capsules. (authors)

  1. Effects of whole-body vibration after eccentric exercise on muscle soreness and muscle strength recovery.

    Science.gov (United States)

    Timon, Rafael; Tejero, Javier; Brazo-Sayavera, Javier; Crespo, Carmen; Olcina, Guillermo

    2016-06-01

    [Purpose] The aim of this study was to investigate whether or not a single whole-body vibration treatment after eccentric exercise can reduce muscle soreness and enhance muscle recovery. [Subjects and Methods] Twenty untrained participants were randomly assigned to two groups: a vibration group (n=10) and control group (n=10). Participants performed eccentric quadriceps training of 4 sets of 5 repetitions at 120% 1RM, with 4 min rest between sets. After that, the vibration group received 3 sets of 1 min whole body vibration (12 Hz, 4 mm) with 30 s of passive recovery between sets. Serum creatine kinase, blood urea nitrogen, muscle soreness (visual analog scale) and muscle strength (peak isometric torque) were assessed. [Results] Creatine kinase was lower in the vibration group than in the control group at 24 h (200.2 ± 8.2 vs. 300.5 ± 26.1 U/L) and at 48 h (175.2 ± 12.5 vs. 285.2 ± 19.7 U/L) post-exercise. Muscle soreness decreased in vibration group compared to control group at 48 h post-exercise (34.1 ± 11.4 vs. 65.2 ± 13.2 mm). [Conclusion] Single whole-body vibration treatment after eccentric exercise reduced delayed onset muscle soreness but it did not affect muscle strength recovery.

  2. Acute effects of whole body gamma irradiation on exocrine pancreatic secretion in the pig

    International Nuclear Information System (INIS)

    Monti, P.; Scanff, P.; Joubert, C.; Vergnet, M.; Grison, S.; Griffiths, N.

    2004-01-01

    Reports on radiation damage to the pancreas deal essentially with long-term morphological changes with few data on pancreatic exocrine function. The aim of this work was to study the acute effects of whole body irradiation on volume and enzyme activities in the pancreatic juice. A whole body gamma irradiation (6 Gy) was investigated in pigs with continuous sampling of pancreatic juice before and after exposure via an indwelling catheter in the pancreatic duct. For each sample collected, total protein concentration and enzyme activities of trypsin, chymotrypsin, elastase, lipase and amylase were determined. Pancreatic juice volume was monitored during all periods of collection. The volume of pancreatic juice secreted daily decreased one day after irradiation and remained lower than the control values over the experimental period. Total proteins secreted in the pancreatic juice and total activities of pancreatic enzymes were reduced similarly. On the other hand, only specific activities of elastase and lipase were affected by irradiation. Whole body gamma irradiation resulted in a rapid and marked decrease of exocrine pancreatic secretion, in terms of volume as well as secreted enzymes. This may contribute in part to the intestinal manifestations of the acute and/or late radiation syndrome. (author)

  3. Experimental autoimmune encephalomyelitis (EAE): lesion visualization on a 3 tesla Clinical whole-body system after intraperitoneal contrast injection

    Energy Technology Data Exchange (ETDEWEB)

    Heckl, S.; Naegele, T.; Klose, U. [Dept. of Neuroradiology, Medical School, Univ. of Tuebingen (Germany); Herrmann, M.; Gaertner, S.; Weissert, R. [Dept. of Neurology, Medical School, Univ. of Tuebingen (Germany); Schick, F. [Dept. of Radiology, Medical School, Univ. of Tuebingen (Germany); Kueker, W. [Dept. of Neuroradiology, Medical School, Univ. of Tuebingen (Germany); Dept. of Neuroradiology, Radcliffe Infirmary, Oxford, England (United Kingdom)

    2004-11-01

    Purpose: To investigate the intravital visibility of CNS lesions in rats with experimental autoimmune encephalomyelitis (EAE), the animal correlate of multiple sclerosis, using a 3-Tesla (T) wholebody MR system. Materials and Methods: Three healthy Dark Agouti (DA) rats and 16 DA rats with clinical signs of EAE were examined on a 3T whole body-system using a normal wrist coil. In total, 25 examinations were preformed using T2- and T1-weighted images in transverse and sagittal orientation with a slice thickness of 2 mm or 1 mm (voxel size up to 0.2 x 0.2 x 1 mm). Sedation was achieved by intraperitoneal injection of ketamine and xylazine. In addition, T1-weighted images were obtained after the instillation of 1.0 ml of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) (0.5 mmol/ml) into the peritoneal cavity. Results: T2- and T1-weighted images of the brain and spinal cord with high spatial and contrast resolution could be obtained in all animals. The anatomical details of the olfactory bulb glomeruli, cerebellum foliae, ventricles and corpus callosum were clearly visible. The EAE lesions presented as hyperintense area in T2-weighted images and could be demonstrated in all clinically affected animals by MRI and histologically verified. In total, the 16 affected rats had 28 cerebral and 2 spinal cord lesions (range 1 to 4, median 2). Contrast enhancement was noted in 12 animals and ranked as severe in ten and moderate in two cases. No adverse effects were noted due to sedation or intraperitoneal contrast injection. Conclusions: The intravital demonstration of cerebral and spinal cord EAE lesions in rats is possible on a 3T whole-body MR scanner using a normal wrist coil. Intraperitoneal injection of ketamine/xylazine and contrast agent is an easy, safe and effective procedure in rats. (orig.)

  4. Integrated PET/MRI for whole-body staging of patients with primary cervical cancer: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, Johannes; Kinner, Sonja; Forsting, Michael; Lauenstein, Thomas; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schaarschmidt, Benedikt Michael [University Hospital Dusseldorf, University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Heubner, Martin; Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Department of Obstetrics and Gynecology, Essen (Germany); Ruhlmann, Verena [University Hospital Essen, University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2015-11-15

    To assess the diagnostic value of integrated PET/MRI for whole-body staging of cervical cancer patients, as well as to investigate a potential association between PET/MRI derived functional parameters and prognostic factors of cervical cancer. The present study was approved by the local institutional review board. Twenty-seven patients with histopathologically confirmed cervical cancer were prospectively enrolled in our study. All patients underwent a whole-body PET/MRI examination after written informed consent was obtained. Two radiologists separately evaluated the PET/MRI data sets regarding the determination of local tumor extent of primary cervical cancer lesions, as well as detection of nodal and distant metastases. Furthermore, SUV and ADC values of primary tumor lesions were analyzed and correlated with dedicated prognostic factors of cervical cancer. Results based on histopathology and cross-sectional imaging follow-up served as the reference standard. PET/MRI enabled the detection of all 27 primary tumor lesions of the uterine cervix and allowed for the correct determination of the T-stage in 23 (85 %) out of the 27 patients. Furthermore, the calculated sensitivity, specificity and diagnostic accuracy for the detection of nodal positive patients (n = 11) were 91 %, 94 % and 93 %, respectively. PET/MRI correctly identified regional metastatic disease (N1-stage) in 8/10 (80 %) patients and non-regional lymph node metastases in 5/5 (100 %) patients. In addition, quantitative analysis of PET and MRI derived functional parameters (SUV; ADC values) revealed a significant correlation with pathological grade and tumor size (p < 0.05). The present study demonstrates the high potential of integrated PET/MRI for the assessment of primary tumor and the detection of lymph node metastases in patients with cervical cancer. Providing additional prognostic information, PET/MRI may serve as a valuable diagnostic tool for cervical cancer patients in a pretreatment setting

  5. Hypertonic/hyperoncotic solution attenuate blood-brain barrier breakdown and brain pathology in whole body hyperthermia rats.

    Science.gov (United States)

    Liu, Youtan; Tang, Jing; Ye, Jionxian; Zhan, Lifang; Huang, Shaonong; Wang, Tingting; Gu, Miaoning

    2011-01-01

    This study was designed to investigate the effects of hypertonic/hyperoncotic solution on blood-brain barrier damage, brain edema and morphological changes of rats during whole body hyperthermia. 90 adult male Sprague-Dawley rats were randomized into 5 groups: Control group (a room temperature for 4 hours); Whole body hyperthermia group without solution treatment; Whole body hyperthermia group with Ringer's solution treatment; Whole body hyperthermia group with hydroxyethyl starch and Ringer's solution treatment; Whole body hyperthermia group with Hypertonic/hyperoncotic solution treatment. All rats except those of control group were housed in a heated container and maintained at 36°C for 3 hours until the rectal temperature reached 41-42°C. Corresponding solutions were administered intravenously at the beginning of whole body hyperthermia within 30 minutes as designed. Following whole body hyperthermia, rats were subsequently cooled down for 1h. Evans blue was administered intravenously when the rectal temperature was cooled down to 37°C. The leakage of Evans blue-albumin and water content of brain were calculated and morphological changes were investigated. In group with hypertonic/hyperoncotic solution treatment, brain water content and the leakage of Evans blue-albumin were the lowest among the four whole body hyperthermia groups. Compared with the other three whole body hyperthermia groups, in which profound to moderate damages to blood-brain barrier and brain tissue and cells were found, there were only slight morphological changes in the group with hypertonic/hyperoncotic solutionon treatment. Treatment with hypertonic/hyperoncotic solution appeared to attenuate the injury to blood-brain barrier and reduce brain edema and cell morphological changes in whole body hyperthermia rats.

  6. Complaints of low back pain among private farmers exposed to whole body vibration

    Directory of Open Access Journals (Sweden)

    Leszek Solecki

    2014-02-01

    Full Text Available Introduction: Work-related lower back disorders , which involve the lumbo-sacral region, as well as injuries of the lumbar section of the spine, are a serious and constantly growing problem in Europe. Whole body vibration is one of the major hazardous factors suspected of the development of back pain. Material and Methods: The study covered a selected group of males, 98 farmers (aged 55.3±10.1 from the area of 7 communes in the Lublin Region, engaged in the mixed agricultural production (plant-animal. The control group consisted of 40 academic workers (university and research institute employees aged 48.9±9.6 years. A questionnaire concerning low back pain (in the lumbar region designed by the researchers of the Institute of Rural Health in Lublin was used as a major research tool. The degree of farmers' exposure to whole body vibration was evaluated based on the parameter known as a cumulative vibration dose (d (years×m2×s-4. Results: The measurements showed that the cumulative vibration dose for the selected group of farmers (98 remained within the range of 2.90-9.68 (years×m2×s-4, in the time interval between 15-50 years of work in conditions of exposure to vibration. The survey confirmed that private farmers exposed to whole body vibration considerably more frequently complained of back pain (92 farmers, 94% of the total number of respondents, than academic workers (control group not exposed to whole body vibration (25 researchers, 63%; p < 0.0001. Also the frequency of back pain in all the three time intervals of employment (15-25, 26-35, 36-50 years is significantly higher in the group of farmers than in the control group (p < 0.05. Conclusions: The frequency of back pains experienced by farmers during the entire period of occupational activity increases with a growing dose of whole body vibration (p = 0.005. In the incidence of chronic pain an upward tendency was observed (statistically insignificant. Med Pr 2014;65(1:55–64

  7. Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

    Directory of Open Access Journals (Sweden)

    Artem Khmelinskii

    Full Text Available Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability. The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers (99mTc-methylene diphosphonate ((99mTc-MDP and (99mTc-hydroxymethane diphosphonate ((99mTc-HDP were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for "incomplete" data (large chunks of skeleton missing and for an intuitive exploration and comparison of multi-modal SPECT

  8. Assessment of exposure to whole body vibration in Yazd city taxi drivers

    Directory of Open Access Journals (Sweden)

    F Samoori sakhvidi

    2016-11-01

    Full Text Available Assessment of exposure to whole body vibration in Yazd city taxi drivers Samoori-Sakhvidi F (MSc* Barkhordari A (PhD** Dehghani A (PhD*** Tavakoli-Manesh S (MSc**** *Corresponding Author: MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran ** Professor, Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran *** Professor, Department of Statistics and Epidemiology, Shahid Sadoughi University of Medical Sciences, Yazd, Iran **** MSc Student in Department of Occupational Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Abstract Introduction: One of the most common sources of whole body vibration are vehicles in which the driver is exposed to vibration caused by the vehicle and the road. Including the people who continuously exposure to whole-body vibration can be noted to taxi drivers. Taxi drivers during their work shift Encountered with numerous deleterious effects such as noise, vibration, air pollution, and psychological stress and long work shifts. Long-term exposure to whole body vibration in the taxi drivers can communicate with adverse effects such as reduce perception, annoyance, disturbance of vision and fine motor tasks, spinal cord injury, damage to the digestive and reproductive systems. The purpose of this study was cross - sectional study of whole body vibration exposure in Yazd city taxi drivers. Methods: This study was designed to evaluate exposure to whole body vibration in taxi drivers, vibration measurement Was carried out in 80 taxi from 3 vehicle (Samand-Peugeot 405 and Pridein 3 mileage groups, with 63 male drivers and 17 female drivers. parameters Including the vibration Weighing the acceleration frequency (rms, Equivalent acceleration (Aeq and vibration doseVDV in 3-axis was recorded. The results obtained were compared with the values recommended by the standard (ISO 2631-1. Results: The mean (rms acceleration

  9. The influence of dietary and whole-body nutrient content on the excretion of a vertebrate consumer.

    Directory of Open Access Journals (Sweden)

    Christopher M Dalton

    Full Text Available In many contexts, nutrient excretion by consumers can impact ecosystems by altering the availability of limiting nutrients. Variation in nutrient excretion can be predicted by mass balance models, most of which are premised on two key ideas: (1 consumers maintain fixed whole-body nutrient content (i.e., %N and %P, so-called fixed homeostasis; (2 if dietary nutrients are not matched to whole-body nutrients, excesses of any nutrient are released as excretion to maintain fixed homeostasis. Mass balance models thus predict that consumer excretion should be positively correlated with diet nutrients and negatively correlated with whole-body nutrients. Recent meta-analyses and field studies, however, have often failed to find these expected patterns, potentially because of a confounding influence-flexibility in whole-body nutrient content with diet quality (flexible homeostasis. Here, we explore the impact of flexible homeostasis on nutrient excretion by comparing the N and P excretion of four genetically diverged Trinidadian guppy (Poecilia reticulata populations when reared on diets of variable P content. As predicted by mass balance, P excretion increased on the high-P diet, but, contrary to the notion of fixed homeostasis, guppy whole-body %P also increased on the high-P diet. While there was no overall correlation between excretion nutrients and whole-body nutrients, when the effect of diet on both whole-body and excretion nutrients was included, we detected the expected negative correlation between whole-body N:P and excretion N:P. This last result suggests that mass balance can predict excretion rates within species, but only if dietary effects on whole-body nutrient content are controlled. Flexible homeostasis can obscure patterns predicted by mass balance, creating an imperative to accurately capture an organism's diet quality in predicting its excretion rate.

  10. Impact of 9 days of bed rest on hepatic and peripheral insulin action, insulin secretion, and whole-body lipolysis in healthy young male offspring of patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Alibegovic, Amra C; Højbjerre, Lise; Sonne, Mette P

    2009-01-01

    OBJECTIVE: The aim of this study was to investigate the impact of 9 days of bed rest on insulin secretion, insulin action, and whole-body glucose and fat metabolism in first-degree relative (FDR) and matched control (CON) subjects. RESEARCH DESIGN AND METHODS: A total of 13 FDR and 20 CON subjects...... deteriorates with 9 days of bed rest, converging toward similar degrees of whole-body insulin resistance. FDR subjects exhibit hepatic insulin resistance (HIR), which, in contrast to CON subjects, deteriorates in response to physical inactivity. FDR subjects exhibit reduced insulin secretion when seen...... participated in the study. All were studied before and after 9 days of bed rest using the clamp technique combined with indirect calorimetry preceded by an intravenous glucose tolerance test. Glucose and glycerol turnover rates were studied using stable isotope kinetics. RESULTS: Bed rest caused a significant...

  11. Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma.

    Science.gov (United States)

    Weckbach, S; Michaely, H J; Stemmer, A; Schoenberg, S O; Dinter, D J

    2010-12-01

    To evaluate a whole body (WB) continuous-table-movement (CTM) MR protocol for the assessment of multiple myeloma (MM) in comparison to a step-by-step WB protocol. Eighteen patients with MM were examined at 1.5T using a WB CTM protocol (axial T2-w fs BLADE, T1-w GRE sequence) and a step-by-step WB protocol including coronal/sagittal T1-w SE and STIR sequences as reference. Protocol time was assessed. Image quality, artefacts, liver/spleen assessability, and the ability to depict bone marrow lesions less than or greater than 1 cm as well as diffuse infiltration and soft tissue lesions were rated. Potential changes in the Durie and Salmon Plus stage and the detectability of complications were assessed. Mean protocol time was 6:38 min (CTM) compared to 24:32 min (standard). Image quality was comparable. Artefacts were more prominent using the CTM protocol (P = 0.0039). Organ assessability was better using the CTM protocol (P < 0.001). Depiction of bone marrow and soft tissue lesions was identical without a staging shift. Vertebral fractures were not detected using the CTM protocol. The new protocol allows a higher patient throughput and facilitates the depiction of extramedullary lesions. However, as long as vertebral fractures are not detectable, the protocol cannot be safely used for clinical routine without the acquisition of an additional sagittal sequence.

  12. Comparison of a new whole-body continuous-table-movement protocol versus a standard whole-body MR protocol for the assessment of multiple myeloma

    International Nuclear Information System (INIS)

    Weckbach, S.; Michaely, H.J.; Schoenberg, S.O.; Dinter, D.J.; Stemmer, A.

    2010-01-01

    To evaluate a whole body (WB) continuous-table-movement (CTM) MR protocol for the assessment of multiple myeloma (MM) in comparison to a step-by-step WB protocol. Eighteen patients with MM were examined at 1.5T using a WB CTM protocol (axial T2-w fs BLADE, T1-w GRE sequence) and a step-by-step WB protocol including coronal/sagittal T1-w SE and STIR sequences as reference. Protocol time was assessed. Image quality, artefacts, liver/spleen assessability, and the ability to depict bone marrow lesions less than or greater than 1 cm as well as diffuse infiltration and soft tissue lesions were rated. Potential changes in the Durie and Salmon Plus stage and the detectability of complications were assessed. Mean protocol time was 6:38 min (CTM) compared to 24:32 min (standard). Image quality was comparable. Artefacts were more prominent using the CTM protocol (P = 0.0039). Organ assessability was better using the CTM protocol (P < 0.001). Depiction of bone marrow and soft tissue lesions was identical without a staging shift. Vertebral fractures were not detected using the CTM protocol. The new protocol allows a higher patient throughput and facilitates the depiction of extramedullary lesions. However, as long as vertebral fractures are not detectable, the protocol cannot be safely used for clinical routine without the acquisition of an additional sagittal sequence. (orig.)

  13. Whole-body versus segmental bioelectrical impedance analysis in patients with edema of the upper limb after breast cancer treatment.

    Science.gov (United States)

    Berlit, Sebastian; Brade, Joachim; Tuschy, Benjamin; Földi, Etelka; Walz-Eschenlohr, Ulrike; Leweling, Hans; Sütterlin, Marc

    2013-08-01

    The purpose of this study was to compare whole-body (50 kHz alternating current) and segmental (5 kHz alternating current) bioelectrical impedance analysis (BIA) in the assessment of manifested edema of the upper limbs. Whole-body and segmental BIA were performed in 30 patients with edema of the upper limb following breast cancer treatment. Pearson correlation coefficient comparing both measurements was 0.8891 (p-value <0.0001) with corresponding least squares (r(2)) of 0.7904. Whole-body BIA seems to be a suitable method in the assessment of manifested edema of the upper limbs.

  14. Can segmental model reductions quantify whole-body balance accurately during dynamic activities?

    Science.gov (United States)

    Jamkrajang, Parunchaya; Robinson, Mark A; Limroongreungrat, Weerawat; Vanrenterghem, Jos

    2017-07-01

    When investigating whole-body balance in dynamic tasks, adequately tracking the whole-body centre of mass (CoM) or derivatives such as the extrapolated centre of mass (XCoM) can be crucial but add considerable measurement efforts. The aim of this study was to investigate whether reduced kinematic models can still provide adequate CoM and XCoM representations during dynamic sporting tasks. Seventeen healthy recreationally active subjects (14 males and 3 females; age, 24.9±3.2years; height, 177.3±6.9cm; body mass 72.6±7.0kg) participated in this study. Participants completed three dynamic movements, jumping, kicking, and overarm throwing. Marker-based kinematic data were collected with 10 optoelectronic cameras at 250Hz (Oqus Qualisys, Gothenburg, Sweden). The differences between (X)CoM from a full-body model (gold standard) and (X)CoM representations based on six selected model reductions were evaluated using a Bland-Altman approach. A threshold difference was set at ±2cm to help the reader interpret which model can still provide an acceptable (X)CoM representation. Antero-posterior and medio-lateral displacement profiles of the CoM representation based on lower limbs, trunk and upper limbs showed strong agreement, slightly reduced for lower limbs and trunk only. Representations based on lower limbs only showed less strong agreement, particularly for XCoM in kicking. Overall, our results provide justification of the use of certain model reductions for specific needs, saving measurement effort whilst limiting the error of tracking (X)CoM trajectories in the context of whole-body balance investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Catecholamine levels in sheep hypothalamus, hypophysis and adrenals following whole-body gamma irradiation

    International Nuclear Information System (INIS)

    Pastorova, B.; Arendarcik, J.; Molnarova, M.

    1985-01-01

    Changes were studied in the levels of catecholamines and L-DOPA in the control system of the reproduction cycle (hypothalamus, hypophysis) and in the adrenal glands of sheep after whole-body irradiation with 60 Co at a total dose of 6.7 Gy for seven days. The output of the radiation source was 0.039 Gy/h. The catecholamines (noradrenaline, dopamine and adrenaline) and L-DOPA were determined after separation from the tissues by the method of spectral fluorometry. After whole-body exposure to gamma radiation, noradrenaline dropped in the hypothalamus in comparison with the control group, most significantly in the rostral (by 74.2%) and caudal (by 40%) parts. A similar drop was also observed in dopamine, the concentrations of which decreased in the rostral hypothalamus by 60%. Adrenaline showed a drop in the hypothalamus, most significant in the caudal region (by 62%). Consequently, the level of the precursor of the synthesis of catecholamines and L-DOPA changed and showed in the studied regions of the hypothalamus significantly lower levels than in the control group. As regards the hypophysis, after irradiation no significant changes in the levels of noradrenaline and adrenaline were recorded, however, dopamine and L-DOPA dropped significantly (P<0.01). The exposure to gamma radiation also causes a decrease in the concentrations of catecholamines and L-DOPA in the adrenal glands of sheep, most significantly in noradrenaline (by 61%). It was thus found that whole-body irradiation of sheep with a dose of 6.7 Gy results in a significant decrease in the level of catecholamines in the hypothalamus, hypophysis and adrenal glands, which is probably in relation to the failure of synthesis and degradation of catecholamines and to the total organism injury

  16. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2013-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaIT1 (8x4″), and thyroid one, NaIT1 (3x3″). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that wasn't exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2007 to December 2012, approximately 6700 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  17. Whole-body measurements of workers occupationally exposed to radionuclides at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Cardoso, Joaquim Carlos S.; Xavier, Marcos

    2015-01-01

    The intake of radioactive material by workers can occur in the radiopharmaceuticals production, during the handling of these in the medical fields (nuclear medicine) and in biological and research laboratories. The workers who work in areas where exposures are significant are routinely monitored to demonstrate that the workers are receiving adequate protection from internal contamination. Direct measurements of whole-body and thyroid contents provide an estimate of the activity of these radionuclides in the potentially exposed workers. The whole-body measurements of the workers, trainees and visitors are routinely performed by the In Vivo Monitoring Laboratory (LMIV) of the Energy and Nuclear Research Institute (IPEN/CNEN-SP). The frequency of measurements is defined by the Radioprotection Service (SRP) and the Dose Calculation Group of IPEN. For this purpose LMIV has two counters, whole body. NaITl (8 x 4”), and thyroid one, NaITl (3 x 3”). The system was calibrated in energy and efficiency, with calibration sources of Eu-152, Am-241 and Co-60 with gamma emissions between 59.54 and 1408.08 keV, positioned within Alderson Research Labs. anthropomorphic phantom. The background measures were obtained of worker's spectrum that was not exposed occupationally yet. The concepts adopted in the HPS N13.30 Standard and proposed in ISO documents for standardization were used for activity measurements. During the period January 2010 to December 2014, approximately 4500 measurements had been carried in workers who develop tasks related to the production and research. The activities of the radionuclides and the workers' tasks relationship had been evaluated. (author)

  18. Changes of whole-body power, muscle function, and jump performance with prolonged cycling to exhaustion.

    Science.gov (United States)

    McIntyre, Jordan P R; Mawston, Grant A; Cairns, Simeon P

    2012-12-01

    To quantify how whole-body power, muscle-function, and jump-performance measures change during prolonged cycling and recovery and determine whether there are relationships between the different fatigue measures. Ten competitive or recreationally active male cyclists underwent repeated 20-min stages of prolonged cycling at 70% VO2peak until exhaustion. Whole-body peak power output (PPO) was assessed using an all-out 30-s sprint 17 min into each cycle stage. Ratings of perceived exertion (RPE) were recorded throughout. Isometric and isokinetic muscle-function tests were made between cycle stages, over ~6 min, and during 30-min recovery. Drop-jump measures were tested at exhaustion and during recovery. PPO initially increased or was maintained in some subjects but fell to 81% of maximum at exhaustion. RPE was near maximal (18.7) at exhaustion, with the time to exhaustion related to the rate of rise of RPE. PPO first started to decline only when RPE exceeded 16 (ie, hard). Peak isometric and concentric isokinetic torque (180°/s) for the quadriceps fell to 86% and 83% of pretest at exhaustion, respectively. In contrast, the peak concentric isokinetic torque (180°/s) of the hamstrings increased by 10% before declining to 93% of maximum. Jump height fell to 92% of pretest at exhaustion and was correlated with the decline in PPO (r = .79). Muscle-function and jump-performance measures did not recover over the 30-min postexercise rest period. At exhaustion, whole-body power, muscle-function, and jump-performance measures had all fallen by 7-19%. PPO and drop-jump decrements were linearly correlated and are appropriate measures of maximal performance.

  19. Effects of Whole-Body 50-Hz Magnetic Field Exposure on Mouse Leydig Cells

    Directory of Open Access Journals (Sweden)

    Zsolt Forgács

    2004-01-01

    Full Text Available The main goal of this study was to evaluate the possible effect of whole-body magnetic field (MF exposure on the steroidogenic capacity of Leydig cells in vitro. In four separate experiments, male CFLP mice were exposed to sinusoidal 50-Hz, 100-μT MF. The duration of exposure was 23.5 h/day over a period of 14 days. At the end of the exposure, interstitial (Leydig cells were isolated from the testicles of the sham-exposed and exposed animals. The cells were cultured for 48 h in the presence or absence of 1, 10, or 100 mIU/ml human chorionic gonadotropin (hCG. The luteinizing hormone (LH analog hCG was used to check the testosterone (T response of the sham-exposed controls and to evaluate the possible effect of the whole-body MF exposure on the steroidogenic capacity of Leydig cells in vitro. Testosterone content of the culture media and blood sera was measured by radioimmunoassay (RIA. In the cultures obtained from MF-exposed animals, the hCG-stimulated T response was significanly higher (p < 0.01 compared with the sham-exposed controls, while the basal T production of cells and the level of serum T remained unaltered. No MF exposure–related histopathological alterations were found in testicles, epididymes, adrenals, prostates, and pituitary glands. The MF exposure did not affect the animal growth rate and the observed hematologic and serum chemical variables. Our results indicate a presumably direct effect of whole-body MF exposure on the hCG-stimulated steroidogenic response of mouse Leydig cells.

  20. Whole-Body Cryotherapy in Athletes: From Therapy to Stimulation. An Updated Review of the Literature

    Directory of Open Access Journals (Sweden)

    Giovanni Lombardi

    2017-05-01

    Full Text Available Nowadays, whole-body cryotherapy is a medical physical treatment widely used in sports medicine. Recovery from injuries (e.g., trauma, overuse and after-season recovery are the main purposes for application. However, the most recent studies confirmed the anti-inflammatory, anti-analgesic, and anti-oxidant effects of this therapy by highlighting the underlying physiological responses. In addition to its therapeutic effects, whole-body cryotherapy has been demonstrated to be a preventive strategy against the deleterious effects of exercise-induced inflammation and soreness. Novel findings have stressed the importance of fat mass on cooling effectiveness and of the starting fitness level on the final result. Exposure to the cryotherapy somehow mimics exercise, since it affects myokines expression in an exercise-like fashion, thus opening another possible window on the therapeutic strategies for metabolic diseases such as obesity and type 2 diabetes. From a biochemical point of view, whole-body cryotherapy not always induces appreciable modifications, but the final clinical output (in terms of pain, soreness, stress, and post-exercise recovery is very often improved compared to either the starting condition or the untreated matched group. Also, the number and the frequency of sessions that should be applied in order to obtain the best therapeutic results have been deeply investigated in the last years. In this article, we reviewed the most recent literature, from 2010 until present, in order to give the most updated insight into this therapeutic strategy, whose rapidly increasing use is not always based on scientific assumptions and safety standards.

  1. Distribution of plutonium and americium in whole bodies donated to the United States Transuranium Registry

    International Nuclear Information System (INIS)

    McInroy, J.F.; Kathren, R.L.; Swint, M.J.

    1989-01-01

    Radiochemical analysis of whole body donations from six former nuclear industry workers 30 or more years post-exposure revealed about 45% of the total body deposition of 239 Pu and 35% of the 241 Am in the respiratory tract of the four cases with inhalation exposure. These proportions are greater than predicted by the current ICRP lung model. Exclusive of the respiratory tract, the mean fractional systemic deposition of 239 Pu in the tissues of five whole bodies was: liver 35.4% ± 12.5%; skeleton 53.7% ± 12.5%; striated muscle 6.5% ± 1.8% and all other organs and tissues 4.4% ± 1.7%. For 241 Am, the comparable values in four cases were liver 6.5% ± 4.8%; skeleton 73.5% ± 12.4%; muscle 14.3% ± 7.6%; and all other tissues and organs 6.65% ± 4.2%. The systemic distribution of 239 Pu was generally consistent with ICRP Publication 30. A significant fraction of both nuclides was retained in the muscle and other soft tissues which serve as long-term storage depots. Initial fractionation of 241 Am between skeleton and liver is consistent with the 50:30 ratio proposed in ICRP Publication 48 assuming an effective clearance half-time from the liver of about 2 y. Estimates of 239 Pu deposition made on the basis of urinalysis results in vivo were typically greater than the observed deposition measured in the tissues of the whole body after death. (author)

  2. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    International Nuclear Information System (INIS)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L.; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M.; Parhofer, Klaus G.; Schoenberg, Stefan O.

    2016-01-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  3. Retrospective analysis of whole-body multislice computed tomography findings taken in trauma patients

    Directory of Open Access Journals (Sweden)

    Ozlem Bingol

    2015-09-01

    Full Text Available Objectives: Using whole-body multislice computed tomography (MSCT excessively or with irrelevant indications can be seen in many centers. The aim of this study was to analyze retrospectively the MSCT findings in trauma patients admitted to the emergency department. Methods: Records of the patients who have applied to the emergency department due to blunt trauma in a 12 month period and whose whole body MSCT images have been taken, were evaluated using the “Nucleus Medical Information System”. Results: The most frequent type of trauma was traffic accidents in 61.4%, falling down from the height in 22.4%, and motorcycle accidents in 11.4% of patients. Of the patients, 25.2% were discharged from the emergency, while 73.8% were hospitalized. At least one CT findings associated with trauma was present in 61.4% of our patients. Pathological findings in MSCT were most frequently detected in the head and face (35.3% and thoracic (28.6% regions, respectively. The most common finding in the head and face region was fractures. The most common pathological findings in the thoracic region were pulmonary contusion and rib fractures. A significant relationship was detected between trauma type and spinal MSCT result (p < 0.001. In a large percentage of the patients, MSCT findings were normal in the abdominal region and genitourinary system. Vertebral fractures were most frequently detected in the thoracolumbar region. Conclusions: In our study, our rate of negative CT was found to be 38.6%, which is a higher ratio compared to other studies conducte on this topic. Keywords: Emergency, Trauma, Whole-body multislice computed tomography

  4. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L. [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Bamberg, Fabian [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lochner, Elena [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); Findeisen, Hannes M. [University Hospital Muenster, Department of Cardiology and Angiology, Muenster (Germany); Parhofer, Klaus G. [Ludwig Maximilians University, Klinikum Grosshadern, Department of Internal Medicine II, Munich (Germany); Schoenberg, Stefan O. [University Medical Center Mannheim, Department of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2016-05-15

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  5. Whole body massage for reducing anxiety and stabilizing vital signs of patients in cardiac care unit.

    Science.gov (United States)

    Adib-Hajbaghery, Mohsen; Abasi, Ali; Rajabi-Beheshtabad, Rahman

    2014-01-01

    Patients admitted in coronary care units face various stressors. Ambiguity of future life conditions and unawareness of caring methods intensifies the patients' anxiety and stress. This study was conducted to assess the effects of whole body massage on anxiety and vital signs of patients with acute coronary disorders. A randomized controlled trial was conducted on 120 patients. Patients were randomly allocated into two groups. The intervention group received a session of whole body massage and the control group received routine care. The levels of State, Trait and overall anxiety and vital signs were assessed in both groups before and after intervention. Independent sample t-test, paired t-test, Chi-square and Fischer exact tests were used for data analysis. The baseline overall mean score of anxiety was 79.43±29.34 in the intervention group and was decreased to 50.38±20.35 after massage therapy (p=0.001). However, no significant changes were occurred in the overall mean anxiety in the control group during the study. The baseline diastolic blood pressure was 77.05±8.12 mmHg and was decreased to 72.18±9.19 mmHg after the intervention (p=0.004). Also, significant decreases were occurred in heart rate and respiration rate of intervention group after massage therapy (p=0.001). However, no significant changes were occurred in vital signs of the control group during the study. The results suggest that whole body massage was effective in reducing anxiety and stabilizing vital signs of patients with acute coronary disorders.

  6. JOURNAL CLUB: CT dose optimization for whole-body PET/CT examinations.

    Science.gov (United States)

    Tonkopi, Elena; Ross, Andrew A; MacDonald, Anita

    2013-08-01

    OBJECTIVE. The objective of this study was to optimize CT protocols for whole-body PET/CT by reducing radiation dose while minimizing effects on image quality. MATERIALS AND METHODS. Before protocol optimization, a survey of 140 consecutive patients was conducted to establish the baseline dose from a whole-body PET/CT examination. Another sample of 100 patients was surveyed to evaluate the reduction of radiation dose after implementation of the new protocol. Effective dose from the CT component of the examination was estimated using dose-length product (DLP) values from reports generated by the scanner and anatomy-specific conversion factors. Twenty-six patients who underwent studies before and after the optimization were included in an analysis of image quality. All 26 patients had maintained the same weight between the examinations and were scanned in the same position using a similar technique except for the changes made for CT dose optimization. The studies were randomized and blinded for an experienced PET and CT reader who graded the imaging quality of anatomic structures. RESULTS. CT protocol optimization resulted in a 32% reduction of the mean CT radiation dose: The mean effective dose was reduced from 8.1 to 5.5 mSv. The blinded analysis of image quality showed no clinically significant degradation of the lower-dose studies. The only structures visualized statistically better on the higher-dose CT scans were the carotid arteries and the region of the posterior triangle. CONCLUSION. The results of this study showed that optimization of CT acquisition can effectively reduce radiation dose in a whole-body PET/CT examination without significantly sacrificing image quality.

  7. Calibration of the LDI/CDTN Whole Body Counter using three physical phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G.; Fonseca, T.C.F. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dep. de Engenharia Nuclear; Mendes, B.M.; Silva, T.A. da; Lacerda, M.A.S.; Pinto, J.R.; Prates, S.; Filho, N.N.A., E-mail: fgpaiva92@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte/MG (Brazil); Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs) at the Unit for Research and Production of Radiopharmaceuticals (UPPR/CDTN), the Research Reactor TRIGA-IPR-R1/CDTN and other workplaces of the institute where there is a risk of accidental intakes. Additionally, LDI supports the Institute of Radiation Protection and Dosimetry (IRD/CNEN) to attend radiological emergencies. The determination of photon emitting radionuclides in the human body requires the use of calibration techniques in different counting geometries for converting the count rates into activity in organs and tissues. This paper presents and discusses the calibration of the LDI/CDTN Whole Body Counter (WBC) using a standard BOMAB phantom (Bottle Mannequin Absorber) compared to a home-made phantom produced with Polyethylene Terephthalate bottles (PET). Initially, the BOMAB was filled with a cocktail containing {sup 60}Co, {sup 137}Cs and {sup 133}Ba. The phantom was counted at the LDI whole body counter and an Efficiency x Energy curve was obtained. Subsequently the PET-BOMAB was filled with the same standard source and a second curve was determined. The efficiency values in each region of interest as well as the shape of both curves were found to be equivalent. The results validate the use of the PET-BOMAB for the calibration of whole body geometry applied to the measurement of high energy photon emitting radionuclides in the energy region evaluated in this work. (author)

  8. Effect of Hippophae leaves on neurotransmitters and hematological parameters in whole body irradiated rats

    International Nuclear Information System (INIS)

    Gupta, Vanita; Prasad, Jagdish; Madhu Bala

    2012-01-01

    Till date no approved radio-protective agent is available world over. WR-2721 had severe side effects and was behaviourally toxic even at sub-lethal doses of ionizing radiation. Seabuckthorn (Hippophae rhamnoides L.) is known for its nutraceutical and therapeutic values. Our studies demonstrated that treatment with leaves of H. rhamnoides rendered > 90% whole body radioprotection in 60 Co-g-irradiated (10 Gy) mice population in comparison to 100% death in non-Hippophae treated irradiated (10 Gy) mice population. Our studies also demonstrated that treatment with leaves of H. rhamnoides prevented conditioned taste aversion (CTA) in irradiated (2 Gy) Sprague-Dawley rats. The present study was planned to evaluate the effects of aqueous extract of Hippophae leaves on changes in levels of neurotransmitters ((acetylcholine esterase (AChE) and dopamine (DA)) in plasma and brain, haematological parameters in blood/plasma; and brain histology in Sprague-Dawley rats showing CTA after 60 Co-g-irradiation (2 Gy). The results showed that whole body 60 Co-g-irradiation (2 Gy) (i) increased the levels of Ach, Eepinephrine (E) and norepinephrine (NE); oxidative stress (MDA and NO), and (ii) decreased the levels of DA; WBC counts and RBC counts and antioxidants (GSH), in comparison to untreated control. Treatment with 12 mg/kg b.w. drug concentration, prior to irradiation significantly (p<0.05) (i) decreased the levels of AChE, E and NE, and MDA and NO levels in plasma and brain, and (ii) increased the WBC counts; RBC counts and levels of antioxidants (GSH), in comparison to radiation control group. Histological changes in brain were also recorded. The results demonstrated that Hippophae leaves extract had neuro-protective and reduced oxidative stress in brain of whole body irradiated mice and could be, thereby contributing to behavioural protection. (author)

  9. Widespread abnormalities on a whole body iodine scan after therapeutic radioiodine due to clothing contamination

    International Nuclear Information System (INIS)

    Kovacs, J.C.; Chatterton, B.E.; Kirdwood, I.D.; Blefari, C.

    2003-01-01

    Full text: A 53-year-old man with a history of papillary thyroid carcinoma was treated with a thyroidectomy and 2 GBq oral 131-Iodine. Whole body scans showed residual thyroid tissue, so a repeat procedure was performed 12 months later. Whole body and planar 131-Iodine scans were performed 7 days post-swallow. The scans showed tracer uptake in the base of the neck, the nose and mouth, as well as activity in the hip and axillary regions, right sub-mandibular gland, left chest anteriorly, liver, hands and feet. The uptake in the right lower neck was consistent with residual thyroid tissue or thyroid cancer. The uptake in the submandibular region and the chest were suspicious of iodine avid metastases, perhaps involving the internal mammary nodes, however, radiological correlation with CT scan showed no evidence of recurrent disease. The low grade diffuse liver uptake was consistent with radio-thyroxine production. The remaining uptake in the hands, feet, hips and axilla were found to be due to contamination. There was significant contamination from the patient's handkerchief and clothing which were worn as an inpatient during therapy and had not yet been washed. Following removal of the contaminated clothing, planar images of the neck and chest and hips were reacquired and a whole body scan was repeated on the following day. 131-Iodine is excreted via the sweat glands, nasal mucosa and salivary glands. Contamination of patient clothing and effects can yield potential false-positive results. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. [Segmentation of whole body bone SPECT image based on BP neural network].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; He, Yuanlie; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2007-10-01

    In this paper, BP neural network is used to segment whole body bone SPECT image so that the lesion area can be recognized automatically. For the uncertain characteristics of SPECT images, it is hard to achieve good segmentation result if only the BP neural network is employed. Therefore, the segmentation process is divided into three steps: first, the optimal gray threshold segmentation method is employed for preprocessing, then BP neural network is used to roughly identify the lesions, and finally template match method and symmetry-removing program are adopted to delete the wrongly recognized areas.

  11. Development of co-registration techniques for comparison of whole-body PET/CT studies

    OpenAIRE

    Libório, André Filipe Cidra Duarte Rocha

    2011-01-01

    The objective of this thesis is to develop an algorithm that co-registers, in a single volume, whole-body Human PET/CT Scans taken at different instants in time, to facilitate the comparison of studies in situations where the patient had to multiple PET/CT exams. The idea is to isolate, from the initials CT volumes, the rigid body parts that can be transformed with a rigid transformation – the bone structures. Bone structures were obtained with segmentation (the process of dividing a volume i...

  12. Whole-body effective half-lives for radiolabeled antibodies and related issues

    Energy Technology Data Exchange (ETDEWEB)

    Kaurin, D.G.L.; Carsten, A.L.; Baum, J.W.; Barber, D.E.

    1996-08-01

    Radiolabeled antibodies (RABs) are being developed and used in medical imaging and therapy in rapidly increasing numbers. Data on the whole body half effective half-lives were calculated from external dose rates obtained from attending physicians and radiation safety officers at participating institutions. Calculations were made using exponential regression analysis of data from patients receiving single and multiple administrations. Theses data were analyzed on the basis of age, sex, isotope label, radiation energy, antibody type, disease treated, administration method, and number of administrations.

  13. Quantification of whole-body bradykinesia in Parkinson's disease participants using multiple inertial sensors.

    Science.gov (United States)

    Memar, Sara; Delrobaei, Mehdi; Pieterman, Marcus; McIsaac, Kenneth; Jog, Mandar

    2018-04-15

    Bradykinesia (slowness of movement) is a common motor symptom of Parkinson's disease (PD) that can severely affect quality of life for those living with the disease. Assessment and treatment of PD motor symptoms largely depends on clinical scales such as the Unified Parkinson's Disease Rating Scale (UPDRS). However, such clinical scales rely on the visual assessment by a human observer, naturally resulting in inter-rater variability. Although previous studies have developed objective means for measuring bradykinesia in PD patients, their evaluation was restricted by the type of movement and number of joints assessed. These studies failed to provide a more comprehensive, whole-body evaluation capable of measuring multiple joints simultaneously. This study utilizes wearable inertial measurement units (IMUs) to quantify whole-body movements, providing novel bradykinesia indices for walking (WBI) and standing up from a chair (sit-to-stand; SBI). The proposed bradykinesia indices include the joint angles at both upper and lower limbs and trunk motion to compute a complete, objective score for whole body bradykinesia. Thirty PD and 11 age-matched healthy control participants were recruited for the study. The participants performed two standard walking tasks that involved multiple body joints in the upper and lower limbs. The WBI and SBI successfully identified differences between control and PD participants. The indices also effectively identified differences within the PD population, distinguishing participants assessed with (ON) and without (OFF) levodopa; the gold-standard of treatment for PD. The goal of this study is to provide health professionals with an objective score for whole body bradykinesia by simultaneously measuring the upper and lower extremities along with truncal movement. This method demonstrates potential to be used in conjunction with current clinical standards for motor symptom assessment, and may also be promising for the remote assessment of PD

  14. Hematological effects of radiant heat-induced whole body hyperthermia on dogs.

    OpenAIRE

    Woods, J P; Schmitt-Tiggelaar, C L; d'Oleire, F; Rosenthal, R C; Robins, H I

    1996-01-01

    The effects on hematological parameters of radiant heat-induced whole body hyperthermia (WBH) at 40.5 degrees C and 41.8 degrees C were determined in 6 normal dogs. Complete blood counts determined prior to WBH, immediately post WBH plateau, and at 1, 2, 7, and 14 days posttreatment did not change significantly following WBH at 40.5 degrees C or 41.8 degrees C. Similarly, no significant changes were detected in platelet counts measured following 40.5 degrees C WBH. In contrast, platelet count...

  15. Semi-portable whole body counter deployable during post-radiological accident

    International Nuclear Information System (INIS)

    Panchal, C.G.; Bansode, P.Y.; Vinod, M.; Sarade, Bhagyashree; Jain, R.K.; Jakati, R.K.; Pithawa, C.K.

    2012-01-01

    A versatile whole body counter with the state of art electronics has been indigenously designed and developed which can be readily deployed for use during nuclear emergency. This instrument is designed to quickly identify and quantify the activity of high energy photon emitters accumulated particularly in vital organs like thyroid, lungs besides the body of the victims of the radiological incident or accident. Special features of the instruments are swivel type detectors assembly mountable on a wall or table top and detachable collimator configurable to assess the internal contamination selectively to meet protective measures of the radiological accidents, mechanically rugged and functionally reliable to perform in contaminated environmental field conditions. (author)

  16. Effect of Multi-axis Whole Body Vibration Exposures and Subject Postures on Typing Performance

    OpenAIRE

    M.K. Bhiwapurkar,; V.H. Saran,; S.P. Harsha

    2010-01-01

    The whole body vibration are known to affect the passenger’s activities such as reading, writing and typing, while traveling by train. An experimental study was therefore performed to investigate the extent of interference in typing task under multi axial random vibration in two seated postures (laptop on lap and on table). The study involved 30 male subjects, were excited with vibrations in three translational axes simultaneously in 1–20 Hz at magnitudes of0.4, 0.8 and 1.2 m/s2. The subjects...

  17. System for whole body imaging and count profiling with a scintillation camera

    International Nuclear Information System (INIS)

    Kaplan, E.; Cooke, M.B.D.

    1976-01-01

    The present invention relates to a method of and apparatus for the radionuclide imaging of the whole body of a patient using an unmodified scintillation camera which permits a patient to be continuously moved under or over the stationary camera face along one axis at a time, parallel passes being made to increase the dimension of the other axis. The system includes a unique electrical circuit which makes it possible to digitally generate new matrix coordinates by summing the coordinates of a first fixed reference frame and the coordinates of a second moving reference frame. 19 claims, 7 figures

  18. Urinary excretion of phthalates and paraben after repeated whole-body topical application in humans

    DEFF Research Database (Denmark)

    Janjua, Nadeem Rezaq; Frederiksen, Hanne; Skakkebaek, Niels E

    2008-01-01

    Diethyl phthalate (DEP), dibutyl phthalate (DBP) and butyl paraben (BP) are man-made chemicals used in personal care products, such as lotions and creams. Exposure to these chemicals causes a variety of adverse reproductive outcomes in animal studies. Humans can be exposed to these chemicals...... were given a whole body topical application of basic cream 2 mg/cm(2) (control week) and then a cream containing 2% (w/w) of DEP, DBP and BP each (treatment week) daily. Twenty-four-hour urine samples were collected. Urinary total, and unconjugated BP, monoethyl phthalate (MEP) and monobutyl phthalate...

  19. Variation in thickness of the large cryosections cut for whole-body autoradiography

    International Nuclear Information System (INIS)

    Ito, Tsunao; Brill, A.B.

    1991-01-01

    A method to assess variation in thickness of the large cryosections for whole-body autoradiography (WBARG) was described, and the degree of intraslice and interslice variations were determined for our cryomicrotome system (LKB PMV-2250). Intraslice variation in thickness of the 180 x 80 mm cryosection was 0.72-0.92 μm within the range of section thickness for WBARG (15-50 μm), and interslice variation was 0.89-1.21 μm. These potential variations in section thickness should be kept in mind whenever working with quantitative WBARG. (author)

  20. Influence of whole-body irradiation on calcium and phosphate homeostasis in the rat

    International Nuclear Information System (INIS)

    Pento, J.T.; Kenny, A.D.

    1975-01-01

    Previous irradiation studies have revealed marked alterations in calcium metabolism. Moreover, the maintenance of calcium homeostasis with parathyroid hormone or calcium salts has been reported to reduce radiation lethality. Therefore, the present study was designed to evaluate the influence of irradiation on calcium homeostasis in the rat. Nine hundred rad of whole-body irradiation produced a significant depression of both plasma calcium and phosphate at 4 days postirradiation. This effect of irradiation was observed to be dose-dependent over a range of 600 to 1200 rad, and possibly related to irradiation-induced anorexia. The physiological significance of these observations is discussed

  1. Myeloid regeneration after whole body irradiation, autologous bone marrow transplantation, and treatment with an anabolic steroid

    International Nuclear Information System (INIS)

    Ambrus, C.M.; Ambrus, J.L.

    1975-01-01

    Stumptail monkeys (Macaca speciosa) received lethal whole-body radiation. Autologous bone marrow injection resulted in survival of the majority of the animals. Treatment with Deca-Durabolin, an anabolic steroid, caused more rapid recovery of colony-forming cell numbers in the bone marrow than in control animals. Both the Deca-Durabolin-treated and control groups were given autologous bone marrow transplantation. Anabolic steroid effect on transplanted bone marrow colony-forming cells may explain the increased rate of leukopoietic regeneration in anabolic steroid-treated animals as compared to controls

  2. Comparison of atlas-based techniques for whole-body bone segmentation

    DEFF Research Database (Denmark)

    Arabi, Hossein; Zaidi, Habib

    2017-01-01

    square distance (MSD) as image similarity measures for calculating the weighting factors, along with other atlas-dependent algorithms, such as (v) shape-based averaging (SBA) and (vi) Hofmann's pseudo-CT generation method. The performance evaluation of the different segmentation techniques was carried...... criterion, global weighting atlas fusion methods provided moderate improvement of whole-body bone segmentation (DSC ='0.65'±'0.05) compared to non-weighted IA (DSC ='0.60'±'0.02). The local weighed atlas fusion approach using the MSD similarity measure outperformed the other strategies by achieving a DSC...

  3. Whole-body effective half-lives for radiolabeled antibodies and related issues

    International Nuclear Information System (INIS)

    Kaurin, D.G.L.; Carsten, A.L.; Baum, J.W.; Barber, D.E.

    1996-08-01

    Radiolabeled antibodies (RABs) are being developed and used in medical imaging and therapy in rapidly increasing numbers. Data on the whole body half effective half-lives were calculated from external dose rates obtained from attending physicians and radiation safety officers at participating institutions. Calculations were made using exponential regression analysis of data from patients receiving single and multiple administrations. Theses data were analyzed on the basis of age, sex, isotope label, radiation energy, antibody type, disease treated, administration method, and number of administrations

  4. Effects of testosterone supplementation on whole body and regional fat mass and distribution in human immunodeficiency virus-infected men with abdominal obesity.

    Science.gov (United States)

    Bhasin, Shalender; Parker, Robert A; Sattler, Fred; Haubrich, Richard; Alston, Beverly; Umbleja, Triin; Shikuma, Cecilia M

    2007-03-01

    Whole body and abdominal obesity are associated with increased risk of diabetes mellitus and heart disease. The effects of testosterone therapy on whole body and visceral fat mass in HIV-infected men with abdominal obesity are unknown. The objective of this study was to determine the effects of testosterone therapy on intraabdominal fat mass and whole body fat distribution in HIV-infected men with abdominal obesity. IN this multicenter, randomized, placebo-controlled, double-blind trial, 88 HIV-positive men with abdominal obesity (waist-to-hip ratio > 0.95 or mid-waist circumference > 100 cm) and total testosterone 125-400 ng/dl, or bioavailable testosterone less than 115 ng/dl, or free testosterone less than 50 pg/ml on stable antiretroviral regimen, and HIV RNA less than 10,000 copies per milliliter were randomized to receive 10 g testosterone gel or placebo daily for 24 wk. Fat mass and distribution were determined by abdominal computerized tomography and dual energy x-ray absorptiometry during wk 0, 12, and 24. We used an intention-to-treat approach and nonparametric statistical methods. Baseline characteristics were balanced between groups. In 75 subjects evaluated, median percent change from baseline to wk 24 in visceral fat did not differ significantly between groups (testosterone 0.3%, placebo 3.1%, P = 0.75). Total (testosterone -1.5%, placebo 4.3%, P = 0.04) and sc (testosterone-7.2%, placebo 8.1%, P fat mass decreased in testosterone-treated men, but increased in placebo group. Testosterone therapy was associated with significant decrease in whole body, trunk, and appendicular fat mass by dual energy x-ray absorptiometry (all P fat increased significantly in the placebo group. The percent of individuals reporting a decrease in abdomen (P = 0.01), neck (P = 0.08), and breast size (P = 0.01) at wk 24 was significantly greater in testosterone-treated than placebo-treated men. Testosterone-treated men had greater increase in lean body mass than placebo

  5. Effect of stochastic resonance whole body vibration on functional performance in the frail elderly: A pilot study.

    Science.gov (United States)

    Kessler, Jessica; Radlinger, Lorenz; Baur, Heiner; Rogan, Slavko

    2014-01-01

    The aim of this pilot study was to evaluate the feasibility and the effect size of a four-week stochastic resonance whole body vibration (SR-WBV) intervention on functional performance and strength in frail elderly individuals. Twenty-seven participants have been recruited and randomly distributed in an intervention group (IG) and a sham group (SG). Primary outcomes were feasibility objectives like recruitment, compliance and safety. Secondary outcomes were short physical performance battery (SPPB), isometric maximum voluntary contraction (IMVC) and isometric rate of force development (IRFD). The intervention was feasible and safe. Furthermore it showed significant effects (p=0.035) and medium effect size (0.43) within the IG in SPPB. SR-WBV training over four weeks with frail elderly individuals is a safe intervention method. The compliance was good and SR-WBV intervention seems to improve functional performance. Further research over a longer time frame for the strength measurements (IMVC and IRFD) is needed to detect potential intervention effects in the force measurements as well. Clinical Trial register: NTC01704976. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Comparison of computational models for estimation of whole body and organ radiation dose in rainbow trout from uptake of iodine-131 - Comparison of rainbow trout phantoms for estimation of whole body and organ radiation dose rates from uptake of iodine-131 in freshwater systems

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Nicole E. [Department of Environmental and Engineering Sciences, Clemson University, Clemson, South Carolina, 29634 (United States); Johnson, Thomas E.; Ruedig, Elizabeth; Pinder, John E. III [Department of Environmental and Radiological Health Sciences, Colorado State University, 1681 Campus Delivery, Fort Collins, Colorado, 80523 (United States)

    2014-07-01

    Internal radiation dose rates to biota are typically calculated utilizing dose conversion factors (DCF), which are values for absorbed dose rate per activity concentration (i.e. mGy d{sup -1} per Bq g{sup -1}). The current methodology employed by both the ICRP and within the ERICA Integrated Approach for calculating dose conversion coefficients is to use Monte Carlo modeling of a homogeneously distributed radionuclide within an ellipsoidal phantom chosen to represent a particular organism. It has been shown that for whole-body DCF, homogenous distribution is a reasonable assumption for electrons, and is associated with an uncertainty of less than 30% for photons. However, if a radionuclide has a specific tissue tropism (e.g. iodine-131 in thyroid) a much higher dose will be received by the organ or tissue than by the whole body. Internal organs are modeled generically as spheres within the ellipsoid phantom, due to the complex and variable nature of organ structure and arrangement within different types of organisms. Ratios of whole-body to organ mass offer conservative conversions of whole-body to organ specific DCF (Gomez-Ros et al 2008), but may considerably overestimate the organ dose; more accurate estimates can be made based on specific absorbed fractions and activity concentrations. Establishment of appropriate screening levels in the regulatory paradigm requires incorporation of sufficient knowledge of dose effects; the ICRP currently lists no derived consideration reference levels for organs, meaning that specific risks associated with organ dose rates are unavailable (ICRP 108). Model comparison and refinement is important in the process of determining both dose rates and dose effects, and here we develop and compare three models for rainbow trout (Oncorhynchus mykiss): the simple geometry described above, a more specific geometry employing anatomically relevant organ size and location, and voxel reconstruction of internal anatomy obtained from CT imaging

  7. Effect of whole-body vibration on muscle strength, spasticity, and motor performance in spastic diplegic cerebral palsy children

    Directory of Open Access Journals (Sweden)

    Marwa M. Ibrahim

    2014-04-01

    Conclusion: The obtained results suggest that 12-weeks’ intervention of whole-body vibration training can increase knee extensors strength and decrease spasticity with beneficial effects on walking speed and motor development in spastic diplegic CP children.

  8. Whole-body fat oxidation determined by graded exercise and indirect calorimetry: a role for muscle oxidative capacity?

    DEFF Research Database (Denmark)

    Nordby, P; Saltin, B; Helge, J W

    2006-01-01

    During whole-body exercise, peak fat oxidation occurs at a moderate intensity. This study investigated whole-body peak fat oxidation in untrained and trained subjects, and the presence of a relation between skeletal muscle oxidative enzyme activity and whole-body peak fat oxidation. Healthy male...... subjects were recruited and categorized into an untrained (N=8, VO(2max) 3.5+/-0.1 L/min) and a trained (N=8, VO(2max) 4.6+/-0.2 L/min) group. Subjects performed a graded exercise test commencing at 60 W for 8 min followed by 35 W increments every 3 min. On a separate day, muscle biopsies were obtained...... oxidation was determined. The body composition was determined by DEXA. Whole-body peak fat oxidation (250+/-25 and 462+/-33 mg/min) was higher (Ptrained compared with untrained subjects, respectively. Muscle...

  9. Targeted microbubbles for imaging tumor angiogenesis: assessment of whole-body biodistribution with dynamic micro-PET in mice

    DEFF Research Database (Denmark)

    Willmann, Jürgen K; Cheng, Zhen; Davis, Corrine

    2008-01-01

    To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice....

  10. The impact of self-reported exposure to whole-body-vibrations on the risk of disability pension among men:

    DEFF Research Database (Denmark)

    Tüchsen, F; Feveile, H; Christensen, KB

    2010-01-01

    -body-vibrations was 1.61 (95% confidence interval (CI) 1.07-2.40) after adjustment for age, smoking habits, BMI, physical job demands and awkward work postures. In our model, with the available explanatory variables, 5.6% of the male disability pension cases were attributable to whole-body-vibrations. Conclusions......Background: Whole-body-vibrations are often associated with adverse health effect but the long term effects are less known. This study investigates the association between occupational exposures to whole-body vibrations, and subsequent transition to disability pension. Methods: A total of 4215 male...... employees were followed up for subsequent disability pension retirement. Exposure to whole-body-vibration was self-reported while new cases of disability pension were retrieved from a national register. Results: The hazard ratio (HR) for disability pension retirement among men exposed to whole...

  11. Muscle MRI / whole-body MRI in diagnosis and dynamic evaluation of neuro-muscular disorders

    Directory of Open Access Journals (Sweden)

    Robert Carlier

    2014-01-01

    Full Text Available The use of MRI in myopathies dates back to more than 20 years. The first investigations were slow and only allowed segmental and limited studies. Whole-body MRI has emerged over the past twelve years and became a useful diagnostic tool in the etiological diagnosis of myopathies and muscular dystrophies. This study must always be confronted with clinical and whichever other paraclinical data without being able to replace them. Indications to perform such an investigation are getting better and better defined and the diagnostic efficacy has progressed with the increasing number of cases, communications, publications and discussions within multidisciplinary working groups. Its noninvasive nature, the radiation-free exposure and its reasonable cost also enable this technique to be easily accepted by the patient. It also provides a valuable tool for monitoring the natural disease progression or the effectiveness of therapies. The radiology team must be acquainted with the management of neuromuscular patients. Interpreting muscle whole-body MRI requires an excellent knowledge of muscle anatomy whichever body part is examined. The radiologist performing these studies is ideally a specialist of musculoskeletal disorders or a neuroradiologist well trained in muscle anatomy.

  12. Antibiotic radioprotection of mice exposed to supralethal whole-body irradiation independent of antibacterial activity

    International Nuclear Information System (INIS)

    Mastromarino, A.; Wilson, R.

    1976-01-01

    Oral administration of streptomycin, kanamycin, neomycin, or gentamicin to specific pathogen-free C57 x Af mice in their drinking water (4 mg/ml) for 2 weeks before supralethal whole-body irradiation very significantly prolonged their mean survival times (8.2 to 8.9 days vs 6.9 for controls) to values which exceed those reported for germ-free mice (7.3 days). The total fecal concentrations of aerobes and anaerobes were reduced by kanamycin, neomycin, and gentamicin. Streptomycin reduced the anaerobes significantly, but not the aerobes. Unlike germ-free mice, these antibiotic-treated mice did excrete free bile acids, products of bacterial action. Oral antibiotic treatment was ineffective in altering the transit time of the intestinal mucosal cells. Previously reported studies had indicated a correlation between decreased transit time and increased survival after irradiation. No significant correlation between mean survival time after irradiation and mucosal transit time was observed. The data demonstrate that certain antibiotics alter the character of the intestinal bacterial flora and increase protection against supralethal doses of whole-body irradiation. It is concluded that the mechanisms of radioresistance in antibiotic-treated mice and germ-free mice are different and that in both groups radioresistance is the result of more than elimination of postirradiation infection

  13. Evaluating image reconstruction methods for tumor detection performance in whole-body PET oncology imaging

    Science.gov (United States)

    Lartizien, Carole; Kinahan, Paul E.; Comtat, Claude; Lin, Michael; Swensson, Richard G.; Trebossen, Regine; Bendriem, Bernard

    2000-04-01

    This work presents initial results from observer detection performance studies using the same volume visualization software tools that are used in clinical PET oncology imaging. Research into the FORE+OSEM and FORE+AWOSEM statistical image reconstruction methods tailored to whole- body 3D PET oncology imaging have indicated potential improvements in image SNR compared to currently used analytic reconstruction methods (FBP). To assess the resulting impact of these reconstruction methods on the performance of human observers in detecting and localizing tumors, we use a non- Monte Carlo technique to generate multiple statistically accurate realizations of 3D whole-body PET data, based on an extended MCAT phantom and with clinically realistic levels of statistical noise. For each realization, we add a fixed number of randomly located 1 cm diam. lesions whose contrast is varied among pre-calibrated values so that the range of true positive fractions is well sampled. The observer is told the number of tumors and, similar to the AFROC method, asked to localize all of them. The true positive fraction for the three algorithms (FBP, FORE+OSEM, FORE+AWOSEM) as a function of lesion contrast is calculated, although other protocols could be compared. A confidence level for each tumor is also recorded for incorporation into later AFROC analysis.

  14. Calibration of the Accuscan II In Vivo System for Whole Body Counting

    Energy Technology Data Exchange (ETDEWEB)

    Orval R. Perry; David L. Georgeson

    2011-08-01

    This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for whole body counting. The source used for the calibration was a NIST traceable BOMAB manufactured by DOE as INL2006 BOMAB containing Eu-154, Eu-155, Eu-152, Sb-125 and Y-88 with energies from 27 keV to 1836 keV with a reference date of 11/29/2006. The actual usable energy range was 86.5 keV to 1597 keV on 4/21/2011. The BOMAB was constructed inside the Accuscan II counting 'tub' in the order of legs, thighs, abdomen, thorax/arms, neck, and head. Each piece was taped to the backwall of the counter. The arms were taped to the thorax. The phantom was constructed between the v-ridges on the backwall of the Accuscan II counter. The energy and efficiency calibrations were performed using the INL2006 BOMAB. The calibrations were performed with the detectors in the scanning mode. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for whole body counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  15. Real-time stylistic prediction for whole-body human motions.

    Science.gov (United States)

    Matsubara, Takamitsu; Hyon, Sang-Ho; Morimoto, Jun

    2012-01-01

    The ability to predict human motion is crucial in several contexts such as human tracking by computer vision and the synthesis of human-like computer graphics. Previous work has focused on off-line processes with well-segmented data; however, many applications such as robotics require real-time control with efficient computation. In this paper, we propose a novel approach called real-time stylistic prediction for whole-body human motions to satisfy these requirements. This approach uses a novel generative model to represent a whole-body human motion including rhythmic motion (e.g., walking) and discrete motion (e.g., jumping). The generative model is composed of a low-dimensional state (phase) dynamics and a two-factor observation model, allowing it to capture the diversity of motion styles in humans. A real-time adaptation algorithm was derived to estimate both state variables and style parameter of the model from non-stationary unlabeled sequential observations. Moreover, with a simple modification, the algorithm allows real-time adaptation even from incomplete (partial) observations. Based on the estimated state and style, a future motion sequence can be accurately predicted. In our implementation, it takes less than 15 ms for both adaptation and prediction at each observation. Our real-time stylistic prediction was evaluated for human walking, running, and jumping behaviors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. High-intensity interval training using whole-body exercises: training recommendations and methodological overview.

    Science.gov (United States)

    Machado, Alexandre F; Baker, Julien S; Figueira Junior, Aylton J; Bocalini, Danilo S

    2017-05-04

    HIIT whole body (HWB)-based exercise is a new calisthenics exercise programme approach that can be considered an effective and safe method to improve physical fitness and body composition. HWB is a method that can be applied to different populations and ages. The purpose of this study was to describe possible methodologies for performing physical training based on whole-body exercise in healthy subjects. The HWB sessions consist of a repeated stimulus based on high-intensity exercise that also include monitoring time to effort, time to recuperation and session time. The exercise intensity is related to the maximal number of movements possible in a given time; therefore, the exercise sessions can be characterized as maximal. The intensity can be recorded using ratings of perceived exertion. Weekly training frequency and exercise selection should be structured according to individual subject functional fitness. Using this simple method, there is potential for greater adherence to physical activity which can promote health benefits to all members of society. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  17. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  18. Routine Yoga Practice Impacts Whole Body Protein Utilization in Healthy Women.

    Science.gov (United States)

    Colletto, Megan; Rodriguez, Nancy

    2018-01-01

    Whole body protein utilization (WBPU), which includes flux (Q), protein synthesis (PS), protein breakdown (PB), and whole body protein balance (WBPB), provides insight regarding muscle mass, a criterion for sarcopenia. To characterize yoga's impact on WBPU, body composition and functional measures in healthy (50-65 years) women. WBPU and functional measures were compared between women who routinely practiced yoga (YOGA; n = 7) and nonactive counterparts (CON; n = 8). Q (0.61 ± 0.06 vs. 0.78 ± 0.07, p = .04), PS (3.07 ± 0.37 vs. 4.17 ± 0.40, p = .03), PB (2.59 ± 0.48 vs. 3.80 ± 0.48, p = .05) were lower, and lean body mass higher (64 ± 1 vs. 58 ± 2%, p ≤ .01) for YOGA vs. CON, respectively. WBPB and functional measures were similar. Routine yoga practice influenced WBPU in healthy older women. Study findings are novel and provide a basis for future investigations evaluating long-term benefits of yoga as an alternative mode of exercise for maintaining muscle mass in support of active aging.

  19. Whole body vibration and posture as risk factors for low back pain among forklift truck drivers

    Science.gov (United States)

    Hoy, J.; Mubarak, N.; Nelson, S.; Sweerts de Landas, M.; Magnusson, M.; Okunribido, O.; Pope, M.

    2005-06-01

    A cross-sectional study was conducted to investigate the risks from whole-body vibration and posture demands for low back pain (LBP) among forklift truck (forklift) drivers. Using a validated questionnaire, information about health history was obtained over a period of two weeks in face-to-face interviews. The forklift drivers were observed in respect of their sitting posture, including frequency with which different positions were adopted (bending, leaning and twisting) and postural analyses were conducted using the OWAS and RULA techniques. Forklift vibrations at the seat (exposure) were measured in the three orthogonal axes ( x-fore and aft, y-lateral and z-vertical) under actual working conditions according to the recommendations of ISO 2631-1. The results showed that LBP was more prevalent amongst forklift drivers than among non-drivers and driving postures in which the trunk is considerably twisted or bent forward associated with greatest risk. Furthermore, forklift drivers showed to be exposed to acceptable levels of vibration in the x- and y-directions (i.e., below the EU Physical Agents Directive on Vibration Exposure recommended action level—0.5 m/s 2), but not in the z-direction. There were indications that whole-body vibration acts associatively with other factors (not independently) to precipitate LBP.

  20. Whole body bone scintigram with sup(99m)Tc-phosphate compounds

    International Nuclear Information System (INIS)

    Oyamada, Hiyoshimaru; Orii, Hirotake; Tabei, Toshio; Ishibashi, Hiroyoshi.

    1975-01-01

    Among the compounds of four different types, which are sup(99m)Tc-polyphosphate suppled by A Company, sup(99m)Tc-pyrophosphate by B Company, and sup(99m)Tc-pyrophosphate of electrolysis method and sup(99m)Tc-diphosphonate by C Company, sup(99m)Tc-diphosphonate showed the most favorable result with a constantly good scintigram quality. The remaining three compounds were found also favorable for clinical application. Besides these are undesirable accumulations, rather low energy of sup(99m)Tc-causes different pictures upon the anterior and the posterior views, and previously irradiated area shows a decreased uptake of these compounds. The usefulness of whole body scintigrams in the detection of metastatic bone tumors was also discussed. There was a definite superiority with this technique over the conventional X-ray study. Especially, in thoracic vertebrae, pelvic bone, and ribs, far many diseased areas were detected on the scintigrams than the areas which the physicians noticed or suspected the metastases. As a conclusion, although there are some problems on the scintigrams, it can be said that sup(99m)Tc-phosphate compounds are very useful in detection of metastatic bone tumors, especially with the help of whole body scanner. (JPN)

  1. LOCALISED MUSCLE TISSUE OXYGENATION DURING DYNAMIC EXERCISE WITH WHOLE BODY VIBRATION

    Directory of Open Access Journals (Sweden)

    Daniel Robbins

    2012-06-01

    Full Text Available Despite increasing use of whole body vibration during exercise an understanding of the exact role of vibration and the supporting physiological mechanisms is still limited. An important aspect of exercise analysis is the utilisation of oxygen, however, there have been limited studies considering tissue oxygenation parameters, particularly during dynamic whole body vibration (WBV exercise. The aim of this study was to determine the effect of adding WBV during heel raise exercises and assessing changes in tissue oxygenation parameters of the lateral gastrocnemius using Near Infra Red Spectroscopy (NIRS. Twenty healthy subjects completed ten alternating sets of 15 heel raises (vibration vs. no vibration. Synchronous oxygenation and motion data were captured prior to exercise to determine baseline levels, for the duration of the exercise and 20 sec post exercise for the recovery period. Both vibration and no vibration conditions elicited a characteristic increase in deoxyhaemoglobin and decreases in oxyhaemoglobin, total haemoglobin, tissue oxygenation index and normalised tissue haemoglobin index which are indicative of local tissue hypoxia. However, the addition of vibration elicited significantly lower (p < 0. 001 depletions in oxyhaemoglobin, total haemoglobin, normalised tissue haemoglobin index but no significant differences in deoxyhaemoglobin. These findings suggest that addition of vibration to exercise does not increase the cost of the exercise for the lateral gastrocnemius muscle, but does decrease the reduction in local muscle oxygenation parameters, potentially resulting from increased blood flow to the calf or a vasospastic response in the feet. However, further studies are needed to establish the mechanisms underlying these findings

  2. Whole-body vibration improves cognitive functions of an adult with ADHD.

    Science.gov (United States)

    Fuermaier, Anselm B M; Tucha, Lara; Koerts, Janneke; van den Bos, Meinris; Regterschot, G Ruben H; Zeinstra, Edzard B; van Heuvelen, Marieke J G; van der Zee, Eddy A; Lange, Klaus W; Tucha, Oliver

    2014-09-01

    Adult attention deficit hyperactivity disorder (ADHD) is associated with a variety of cognitive impairments, which were shown to affect academic achievement and quality of life. Current treatment strategies, such as stimulant drug treatment, were demonstrated to effectively improve cognitive functions of patients with ADHD. However, most treatment strategies are associated with a number of disadvantages in a considerable proportion of patients, such as unsatisfactory effects, adverse clinical side effects or high financial costs. In order to address limitations of current treatment strategies, whole-body vibration (WBV) might represent a novel approach to treat cognitive dysfunctions of patients with ADHD. WBV refers to the exposure of the whole body of an individual to vibration and was found to affect physiology and cognition. In the present study, WBV was applied on 10 consecutive days to an adult diagnosed with ADHD. Neuropsychological assessments were performed repeatedly at three different times, i.e., the day before the start of the treatment, on the day following completion of treatment and 14 days after the treatment have been completed (follow-up). An improved neuropsychological test performance following WBV treatment points to the high clinical value of WBV in treating patients with neuropsychological impairments such as ADHD.

  3. Low-Dose Adefovir-Induced Hypophosphatemic Osteomalacia on Whole-Body Bone Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Won, Kyoung Sook; Song, Bongil; Jo, Il; Zeon, Seok Kil [Keimyung Univ., Daegu (Korea, Republic of)

    2013-12-15

    While adefovir dipivoxil (ADV) effectively suppresses the hepatitis B virus, it can cause proximal renal tubular dysfunction leading to phosphate wasting. The safety of low-dose ADV (a dose of 10 mg/day), which does not induce clinically significant nephrotoxicity, is well recognized, but a few cases of hypophosphatemic osteomalacia (HO) caused by low-dose ADV therapy have recently been reported. Although HO induced by low-dose ADV therapy is rare, the presence of bone pain in patients treated with ADV should be monitored. Bone scintigraphy can be performed to confirm the occurrence of osteomalacia and to determine the disease extent. Bone scintigraphic and radiological image findings with a brief review of the literature are presented in this article. We report two cases of HO induced by low-dose ADV therapy that showed multifocal increased radiotracer uptakes in the bilateral bony ribs, spines, pelvic bones and lower extremities on whole-body bone scintigraphy. Bone pain gradually improved after phosphate supplementation and by changing the antiviral agent. Whole-body bone scintigraphy is a highly sensitive imaging tool and can show disease extent at once in the setting of the wide range of the clinical spectrum with nonspecific radiological findings. Furthermore, frequent involvement of the lower extremities, as a result of maximum weight bearing, could be an additional scintigraphic clue for the diagnosis of HO. These cases could be helpful for both clinicians prescribing ADV and nuclear physicians to prevent delayed diagnosis and plan further appropriate treatment.

  4. Evaluation of skeletal muscular involvement in neuromuscular disorders with thallium-201 whole body scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Sotobata, Iwao; Indo, Toshikatsu; Matsuoka, Yukihiko; Matsushima, Hideo; Suzuki, Akio; Abe, Tetsutaro; Sakuma, Sadayuki

    1986-01-01

    The extent as well as severity of pathologic changes of skeletal muscles were analyzed with thallium-201 whole body scintigraphy (WBS) in 29 cases of various types of neuromuscular diseases (18 cases of myogenic and 11 cases of neurogenic muscular diseases) and 14 cases of normal controls. After intravenous injection of 2 mCi of thallium-201 chloride, WBS was performed for 15 minutes using a gamma camera with twin-opposed large rectangular detectors. Counts at brachia, forearms, thighs, and calves were assessed after reconstruction of the scintigram of the whole body by taking the geometric mean of the anterior and posterior data. WBS showed uniform tracer activities in the 4 extremities in 12 cases among 14 controls. Laterality in distribution of counts of both legs and arms was noted in the remaining 2 controls. WBS revealed decrease of perfusion in the extremities with muscular atrophy and/or weakness in neuromuscular diseases. The overall diagnostic accuracy of WBS for evaluation of skeletal muscle involvement was 75 to 80 % except for the bilateral brachia for which it decreased to 65 %. All of the three cases of muscular dystrophy with pseudohypertrophy of the calves or thighs showed unequivocal decrease of perfusion of those regions in WBS. In conclusion, thallium-201 WBS was considered to be a useful clinical means in evaluating the extent and severity of muscular involvement of various types of neuromuscular disorders. (author)

  5. Whole-body prepulse inhibition protocol to test sensorymotor gating mechanisms in monkeys.

    Science.gov (United States)

    Saletti, Patricia G; Maior, Rafael S; Hori, Etsuro; Almeida, Ricardo Miyasaka de; Nishijo, Hisao; Tomaz, Carlos

    2014-01-01

    Prepulse inhibition (PPI) is the decrease of startle reflex amplitude when a slight stimulus is previously generated. This paradigm may provide valuable information about sensorimotor gating functionality. Here we aimed at determining the inhibited and uninhibited startle response of capuchin monkeys (Sapajus spp.), and to evaluate the role of the superior colliculus in PPI. Capuchin monkeys were tested in a whole-body protocol, to determine the best startle amplitude and interstimuli interval. Additionally we tested two subjects with bilateral superior colliculus damage in this protocol. Results show that 115 dB auditory pulse has induced the best startle response. In contrast to reports in other species, no habituation to the auditory stimuli was observed here in capuchins. Also, startle reflex inhibition was optimal after 120 msec interstimuli interval. Finally, there was a downward tendency of percentage inhibition in superior colliculus-lesioned monkeys. Our data provides the possibility of further studies with whole-body protocol in capuchin monkeys and reinforces the importance of the superior colliculus in PPI.

  6. iCub Whole-body Control through Force Regulation on Rigid Noncoplanar Contacts

    Directory of Open Access Journals (Sweden)

    Francesco eNori

    2015-03-01

    Full Text Available This paper details the implementation on the humanoid robot iCub of state-of-the-art algorithms for whole-body control. We regulate the forces between the robot and its surrounding environment to stabilize a desired robot posture. We assume that the forces and torques are exerted on rigid contacts. The validity of this assumption is guaranteed by constraining the contact forces and torques, e.g. the contact forces must belong to the associated friction cones. The implementation of this control strategy requires to estimate the external forces acting on the robot, and the internal joint torques. We then detail algorithms to obtain these estimations when using a robot with an iCub-like sensor set, i.e. distributed six-axis force-torque sensors and whole-body tactile sensors. A general theory for identifying the robot inertial parameters is also presented. From an actuation standpoint, we show how to implement a joint torque control in the case of DC brushless motors. In addition, the coupling mechanism of the iCub torso is investigated. The soundness of the entire control architecture is validated in a real scenario involving the robot iCub balancing and making contacts at both arms.

  7. Automatic Vertebral Column Extraction by Whole-Body Bone SPECT Scan

    Directory of Open Access Journals (Sweden)

    Sheng-Fang Huang

    2013-01-01

    Full Text Available Bone extraction and division can enhance the accuracy of diagnoses based on whole-body bone SPECT data. This study developed a method for using conventional SPECT for automatic recognition of the vertebral column. A novel feature of the proposed approach is a novel “bone graph" image description method that represents the connectivity between these image regions to facilitate manipulation of morphological relationships in the skeleton before surgery. By tracking the paths shown on the bone graph, skeletal structures can be identified by performing morphological operations. The performance of the method was evaluated quantitatively and qualitatively by two experienced nuclear medicine physicians. Datasets for whole-body bone SPECT scans in 46 lung cancer patients with bone metastasis were obtained with Tc-99m MDP. The algorithm successfully segmented vertebrae in the thoracolumbar spine. The quantitative assessment shows that the segmentation method achieved an average TP, FP, and FN rates of 95.1%, 9.1%, and 4.9%. The qualitative evaluation shows an average acceptance rate of 83%, where the data for the acceptable and unacceptable groups had a Cronbach’s alpha value of 0.718, which indicated reasonable internal consistency and reliability.

  8. Whole body positron emission tomography in follow-up of high risk melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Koskivuo, Ilkka O.; Suominen, Erkki A. [Dept. of Surgery, Turku Univ. Hospital (Finland); Seppaenen, Marko P.; Minn, Heikki R.I. [Turku PET Centre, Turku Univ. Hospital (Finland)

    2007-07-15

    The aim of this study was to determine the clinical impact of whole body positron emission tomography (FDG PET) to detect clinically silent metastases in the follow-up of patients with high risk melanoma. FDG PET was performed to 30 asymptomatic melanoma patients (AJCC stage IIB-IIIC) 7-24 months after the primary surgery and sentinel node biopsy. FDG PET was able to detect six of seven recurrences, constituting 20% of all study patients. One patient presented with a negative FDG PET finding at the very first scanning, but was positive later in a repeated scan after manifestation of palpable mass in the axilla. The positive PET finding had an impact on treatment decisions in every case: three patients underwent surgical resection and four patients received chemotherapy or interferon. The mean follow-up time was 27 months (range, 12-48 months) and during that time the other 23 patients with true negative FDG PET were disease-free. One of the seven recurrences was in remission after surgical metastasectomy. In conclusion, whole body FDG PET is a valuable follow-up tool in high risk melanoma to diagnose recurrences and to select the patients, who are suitable for surgical metastasectomy.

  9. Critical review of beige adipocyte thermogenic activation and contribution to whole-body energy expenditure.

    Science.gov (United States)

    Castro, Érique; Silva, Tiago E Oliveira; Festuccia, William T

    2017-09-01

    Beige (or brite, "brown in white") adipocytes are uncoupling protein 1 (UCP1)-positive cells residing in white adipose depots that, depending on the conditions, behave either as classic white adipocytes, storing energy as lipids, or as brown adipocytes, dissipating energy from oxidative metabolism as heat through non-shivering thermogenesis. Because of their thermogenic potential and, therefore, possible usage to treat metabolic diseases such as obesity and type 2 diabetes, beige cells have attracted the attention of many scientists worldwide aiming to develop strategies to safely recruit and activate their thermogenic activity. Indeed, in recent years, a large variety of conditions, molecules (including nutrients) and signaling pathways were reported to promote the recruitment of beige adipocytes. Despite of those advances, the true contribution of beige adipocyte thermogenesis to whole-body energy expenditure is still not completely defined. Herein, we discuss some important aspects that should be considered when studying beige adipocyte biology and the contribution to energy balance and whole-body metabolism.

  10. Hematological profile and martial status in rugby players during whole body cryostimulation.

    Directory of Open Access Journals (Sweden)

    Giovanni Lombardi

    Full Text Available Cold-based therapies are commonly applied to alleviate pain symptoms secondary to inflammatory diseases, but also to treat injuries or overuse, as done in sports rehabilitation. Whole body cryotherapy, a relatively new form of cold therapy, consists of short whole-body exposure to extremely cold air (-110°C to -140°C. Cryostimulation is gaining wider acceptance as an effective part of physical therapy to accelerate muscle recovery in rugby players. The aim of this study was to evaluate the effect of repeated cryostimulation sessions on the hematological profile and martial status markers in professional rugby players. Twenty-seven professional rugby players received 2 daily cryostimulation treatments for 7 consecutive days. Blood samples were collected before and after administration of the cryotherapic protocol and hematological profiles were obtained. No changes in the leukocyte count or composition were seen. There was a decrease in the values for erythrocytes, hematocrit, hemoglobin and mean corpuscular hemoglobin content, and an increase in mean corpuscular volume and red cell distribution width. Platelet count and mean volume remained unchanged. Serum transferrin and ferritin decreased, while soluble transferrin receptor increased. Serum iron and transferrin saturation were unchanged, as was reticulocyte count, whereas the immature reticulocyte fraction decreased substantially. In conclusion, in this sample of professional rugby players, cryostimulation modified the hematological profile, with a reduction in erythrocyte count and hemoglobinization paralleled by a change in martial status markers.

  11. Plutonium fecal and urinary excretion functions: Derivation from a systematic whole-body retention function

    International Nuclear Information System (INIS)

    Sun, C.; Lee, D.

    1999-01-01

    Liver-bile secretion directly influences the content of plutonium in feces. To assess the reliability of plutonium metabolic models and to improve the accuracy of interpreting plutonium fecal data, the authors developed a compartmental model that simulates the metabolism of plutonium in humans. With this model, they can describe the transport of plutonium contaminants in the systemic organs and tissues of the body, including fecal and urine excretions, without using elaborate kinetic information. The parameter values of the models, which describe the translocation rates and recycling of plutonium in the body, can be derived from a multi-term exponential systemic function for whole-body retention. The analytical derivations and algorithms for solving translocation parameter values are established for the model and illustrated by applying them to the biokinetics and bioassay of plutonium. This study describes how to (1) design a physiological model for incorporating liver biliary secretion and for obtaining a fecal-excretion function, (2) develop an analytical solution for identifying the translocation-parameter values incorporating the recycling of plutonium in the body, and (3) derive a set of urinary and fecal excretion-functions from a published systemic whole-body retention function, generally acknowledged to be accurate, as a real and practical example

  12. Enhancement of committed hematopoietic stem cell colony formation by nandrolone decanoate after sublethal whole body irradiation

    International Nuclear Information System (INIS)

    Gallicchio, V.S.; Chen, M.G.; Watts, T.D.

    1984-01-01

    The ability of an anabolic steroid, nandrolone decanoate, to increase committed topoietic stem cell (CFU-gm, CFU-e, and BFU-e) colony formation after sublethal irradiation was evaluated. Immediately after receiving whole body irradiation and on the next two days, each mouse was injected intraperitoneally with nandrolone decanoate (1.25 mg) in propylene glycol. Irradiated control mice received only propylene glycol. Compared to controls, drug-treated mice showed marked peripheral blood leukocytosis and more stable packed red cell volume. Drug-treated mice also demonstrated increased erythropoiesis, as CFU-e/BFU-e concentrations from both marrow (9% to 581%) and spleen (15% to 797%) were elevated. Granulopoiesis was increased similarly, as CFU-gm concentrations from marrow (38% to 685%) and spleen (9% to 373%) were elevated. These results demonstrate that nandrolone decanoate enhances hematopoietic stem cell recovery after sublethal whole body irradiation. This suggests that following hematopoietic suppression, nandrolone decanoate may stimulate the recovery of hematopoiesis at the stem cell level and in peripheral blood

  13. Enhancement of committed hematopoietic stem cell colony formation by nandrolone decanoate after sublethal whole body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gallicchio, V.S.; Chen, M.G.; Watts, T.D.

    1984-11-01

    The ability of an anabolic steroid, nandrolone decanoate, to increase committed topoietic stem cell (CFU-gm, CFU-e, and BFU-e) colony formation after sublethal irradiation was evaluated. Immediately after receiving whole body irradiation and on the next two days, each mouse was injected intraperitoneally with nandrolone decanoate (1.25 mg) in propylene glycol. Irradiated control mice received only propylene glycol. Compared to controls, drug-treated mice showed marked peripheral blood leukocytosis and more stable packed red cell volume. Drug-treated mice also demonstrated increased erythropoiesis, as CFU-e/BFU-e concentrations from both marrow (9% to 581%) and spleen (15% to 797%) were elevated. Granulopoiesis was increased similarly, as CFU-gm concentrations from marrow (38% to 685%) and spleen (9% to 373%) were elevated. These results demonstrate that nandrolone decanoate enhances hematopoietic stem cell recovery after sublethal whole body irradiation. This suggests that following hematopoietic suppression, nandrolone decanoate may stimulate the recovery of hematopoiesis at the stem cell level and in peripheral blood.

  14. Whole-body magnetic resonance angiography of patients using a standard clinical scanner

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Tomas; Wikstroem, Johan; Eriksson, Mats-Ola; Lundberg, Anders; Ahlstroem, Haakan [Uppsala University Hospital, Department of Diagnostic Radiology, Uppsala (Sweden); Johansson, Lars [Uppsala University Hospital, Uppsala (Sweden); Ljungman, Christer [Uppsala University Hospital, Department of Vascular Surgery, Uppsala (Sweden); Hoogeven, Romhild [Philips Medical Systems, MR Clinical Science, Best (Netherlands)

    2006-01-01

    The purpose of this study was to evaluate the technique of whole-body magnetic resonance angiography (MRA) of patients with a standard clinical scanner. Thirty-three patients referred for stenoses, occlusions, aneurysms, assessment of patency of vascular grafts, vasculitis and vascular aplasia were examined in a 1.5-T scanner using its standard body coil. Three-dimensional sequences were acquired in four stations after administration of one intravenous injection of 40 ml conventional gadolinium contrast agent. Different vessel segments were evaluated as either diagnostic or nondiagnostic and regarding the presence of stenoses with more than 50% diameter reduction, occlusions or aneurysms. Of 923 vessel segments, 67 were not evaluable because of poor contrast filling (n=31), motion artefacts (n=20), venous overlap (n=12) and other reasons (n=4). Stenoses of more than 50%, occlusions or aneurysms were observed in 26 patients (129 segments). In nine patients additional unsuspected pathology was found. In 10 out of 14 patients (71/79 segments) there was conformity between MRA and digital subtraction angiography regarding the grade of stenosis. This study shows that whole-body MRA with a standard clinical scanner is feasible. Motion artefacts and the timing of the contrast agent through the different segments are still problems to be solved. (orig.)

  15. Predicting health risks of exposure to whole body vibration in the urban taxi drivers

    Directory of Open Access Journals (Sweden)

    Keykaous Azrah

    2016-09-01

    Full Text Available Introduction: Limited studies have been done to evaluate the whole-body vibration (WBV exposure experienced by Taxi drivers. Therefore, the aim of this study was to evaluate the exposure to whole body vibration and repeated shocks in urban taxi drivers and also to compare different methods of evaluation in this job environment. Material and Method: Measurement and evaluation process were conducted in accordance with procedure of the ISO 2631-1 and ISO 2631-5 standards. The measurements were done by SVAN 958 Sound and Vibration Analyzer and using tri-axial accelerometer centered on the contact surface between the seat and the driver in 9 taxis.   Result: The measurements done according to ISO 2631-1 method showed greater risk compared to Daily Equivalent Static Compression Dose, Sed, presented in ISO 2631-5. Calculated daily exposure durations for exposure action level in root-mean square, vibration dose value, and daily equivalent static compressive stress methods were 4.55, 3.54 and 31.70 hours, respectively. Conclusion: The large differences in estimated exposure durations of action limits and permissible limits resulted by different methods reflect the inconsistency of the selected evaluation methods. Therefore, future research is necessary to amend the limits presented in the standard.

  16. Expression of IL-1{beta} mRNA in mice after whole body X-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Kumie; Ishihara, Hiroshi; Tanaka, Izumi; Suzuki, Gen; Tsuneoka, Kazuko; Yoshida, Kazuko; Ohtsu, Hiroshi [National Inst. of Radiological Sciences, Chiba (Japan)

    1995-06-01

    IL-1{beta} is a stimulator of hematopoietic and inflammatory systems, and also acts as a radioprotector. After whole-body exposure to sublethal doses of ionizing radiation, the IL-1{beta} mRNA level in spleen cells increases for a short time prior to regeneration of the spleen. We analyzed spleen cells of C3H/He mice after whole-body irradiation with 3 Gy x-rays to determine the cause of this short-term increase in the transcription level. An increase in the level of the message in spleen cells, found by Northern blot hybridization, reached its peak 5 to 7 days after irradiation. There was a low correlation between the curves of the mRNA level and the ratio of monocyte/macrophage lineage cells; a typical source of the message. Spleen macrophages that produce a large amount of the message were found 7 days after irradiation in an in situ hybridization experiment in which heterogeneous spleen cell populations were used. In contrast, spleen cells had no detectable levels of macrophages rich in IL-1{beta} mRNA before and 17 days after irradiation. Additionally, the population of message-rich cells was 9.4% of the total number of monocytes/macrophages in the spleen. These results suggest that the short-term increase in IL-1{beta} mRNA is a result of the heterogeneous differentiation of a subpopulation of spleen macrophages before regeneration of the spleen. (author).

  17. Calcium metabolism in fluorosis and endemic genu valgum using radioactive tracer, whole body counting and radioimmunoassay

    International Nuclear Information System (INIS)

    Narasinga Rao, B.

    1979-11-01

    Endemic fluorosis with extensive skeletal changes has been reported from several parts of India. In recent years a new condition, endemic genu valgum, has been recognized in one of these areas. In both conditions osteosclerosis, particularly of the spine, has been observed, but in genu valgum the most distinctive pathology is osteoporosis in bones of the extremities and presumably as a result the ''knock knees'' that give the syndrome its name. In this project certain aspects of calcium metabolism were investigated in endemic fluorosis and genu valgum and in appropriate control subjects. Calcium kinetics were studied by intravenously injecting a tracer dose of 47 Ca and following for 10 days thereafter the concentration of the tracer in serum and excreta, as well as its total retention in the body (the latter measured by whole body counting). In addition calcium balance was measured on some of the subjects while resident in a metabolic ward. Statistical analysis of the results showed in general a higher metabolic activity of calcium in the fluorosis and genu valgum cases than in the controls (specifically, higher ''turnover'' of calcium in the blood pool and an apparently elevated bone mineralization rate). Whole body retention was somewhat greater in the patients than in the controls. Several measurements were also performed relative to blood chemistry, and in particular the serum concentration of 25-OHD 3 (a metabolite of vitamin D) was measured. There was no evidence that vitamin D deficiency played a significant role in the causation of genu valgum

  18. Computational modeling of blast induced whole-body injury: a review.

    Science.gov (United States)

    Chanda, Arnab; Callaway, Christian

    2018-02-01

    Blast injuries affect millions of lives across the globe due to its traumatic after effects on the brain and the whole body. To date, military grade armour materials are designed to mitigate ballistic and shrapnel attacks but are less effective in resisting blast impacts. In order to improve blast absorption characteristics of armours, the first key step is thoroughly understands the effects of blasts on the human body itself. In the last decade, a plethora of experimental and computational work has been carried out to investigate the mechanics and pathophysiology of Traumatic Brain Injury (TBI). However, very few attempts have been made so far to study the effect of blasts on the various other parts of the body such as the sensory organs (eyes and ears), nervous system, thorax, extremities, internal organs (such as the lungs) and the skeletal system. While an experimental evaluation of blast effects on such physiological systems is difficult, developing finite element (FE) models could allow the recreation of realistic blast scenarios on full scale human models and simulate the effects. The current article reviews the state-of-the-art in computational research in blast induced whole-body injury modelling, which would not only help in identifying the areas in which further research is required, but would also be indispensable for understanding body location specific armour design criteria for improved blast injury mitigation.

  19. Low-Dose Adefovir-Induced Hypophosphatemic Osteomalacia on Whole-Body Bone Scintigraphy

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Won, Kyoung Sook; Song, Bongil; Jo, Il; Zeon, Seok Kil

    2013-01-01

    While adefovir dipivoxil (ADV) effectively suppresses the hepatitis B virus, it can cause proximal renal tubular dysfunction leading to phosphate wasting. The safety of low-dose ADV (a dose of 10 mg/day), which does not induce clinically significant nephrotoxicity, is well recognized, but a few cases of hypophosphatemic osteomalacia (HO) caused by low-dose ADV therapy have recently been reported. Although HO induced by low-dose ADV therapy is rare, the presence of bone pain in patients treated with ADV should be monitored. Bone scintigraphy can be performed to confirm the occurrence of osteomalacia and to determine the disease extent. Bone scintigraphic and radiological image findings with a brief review of the literature are presented in this article. We report two cases of HO induced by low-dose ADV therapy that showed multifocal increased radiotracer uptakes in the bilateral bony ribs, spines, pelvic bones and lower extremities on whole-body bone scintigraphy. Bone pain gradually improved after phosphate supplementation and by changing the antiviral agent. Whole-body bone scintigraphy is a highly sensitive imaging tool and can show disease extent at once in the setting of the wide range of the clinical spectrum with nonspecific radiological findings. Furthermore, frequent involvement of the lower extremities, as a result of maximum weight bearing, could be an additional scintigraphic clue for the diagnosis of HO. These cases could be helpful for both clinicians prescribing ADV and nuclear physicians to prevent delayed diagnosis and plan further appropriate treatment

  20. Open-Ended Measurement of Whole-Body Movement: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Finn, Michael T. M.

    2018-02-01

    Full Text Available As the importance of embodiment emerges for psychology, there is a need to advance methodology for measuring the dynamics of movement in an open-ended fashion. Such a tool should be versatile across contexts and track spontaneous and natural movement with minimal constraints. We test the feasibility of a method for measuring whole-body movement over time that attempts to meet this need. We use a motion capture system comprised of two Microsoft Kinect version 2.0 cameras and iPiSoft Motion Capture software, and compare its estimates of magnitude rotational velocity and whole-body movement complexity (multivariate multiscale sample entropy; MMSE to that of a gold standard motion capture system across a variety of movement sequences. The candidate system satisfactorily estimated the instantaneous velocity of 13 body segments in agreement with the gold standard system across movement sequences demonstrating initial feasibility of this process. Summary calculations of velocity by sequence and MMSE calculations were also in high agreement with the gold standard, crucially suggesting that the candidate system could pick up on the complex dynamics of movement over time. The candidate system was feasible and demonstrates preliminary validity for general use in the tracking of continuous human movement for clinical and experimental psychology. We also provide R code and sample data for the importing and processing of movement data exported from iPiSoft Motion Capture Studio.

  1. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    International Nuclear Information System (INIS)

    Maroy, R.; Boisgard, R.; Comtat, C.; Dolle, F.; Trebossen, R.; Tavitian, B.; Frouin, V.; Cathier, P.; Duchesnay, E.; D; Nielsen, P.E.

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together with physiological movements (heart beating, breathing, and bladder filling). The method was resistant to spillover and physiological movements, while other methods failed to obtain a correct segmentation. The radioactivity concentrations calculated with this method also showed an excellent correlation with the manual delineation of organs in a large set of preclinical images. In addition, it was faster, detected more organs, and extracted organs' mean time activity curves with a better confidence on the measure than manual delineation. (authors)

  2. Development of fibrosis in dogs as a late consequence of whole-body X-irradiation

    International Nuclear Information System (INIS)

    Calvo, W.; Fliedner, T.M.; Steinbach, I.; Alcober, V.; Nothdurft, W.; Fache, I.

    1978-01-01

    Dogs wre whole-body irradiated with a single mid-line dose of 1200 R at 300 kV. This high dose will kill non-treated animals within a few days. To save these animals, leukocytes were previously collected during a four-hour leukapheresis using a continuous-flow centrifuge and were stored under liquid nitrogen. Shortly after the whole-body irradiation each dog received its own cryopreserved cells thawed immediately beforehand. The dogs received between 0.32x10 9 and 1.63x10 9 mononuclear blood cells per kilogram of body weight. The number of colony-forming cells contained in the transfusate ranged between 0.19x10 5 and 1.38x10 5 per kilogram of body weight. This blood stem transfusion, together with general supportive therapy, enabled the dogs to overcome the acute radiation syndrome and to recover. The dogs were subsequently sacrificed in two groups after observation for about 260 days or 700-898 days respectively. Pathological findings are described. A particular situation existed in the marrow, whre non-irradiated stem cells had colonized bone cavities containing irradiated stroma. Progressive fibrosis developed in the endosteal areas of the bone cavities in most of the animals. (author)

  3. Rat cardiovascular responses to whole body suspension - Head-down and non-head-down tilt

    Science.gov (United States)

    Musacchia, X. J.; Steffen, Joseph M.; Dombrowski, Judy

    1992-01-01

    Two experiments aimed at examining the versatility of the whole body suspension (WBS) system as a ground-based model for cardiovascular effects of microgravity are described. The first experiment studied heart rate and arterial pressure responses in rats during a 7-day period of head-down tilt (HDT) or nonhead-down tilt (NHDT) and after removal from whole body suspension (WBS). Mean arterial (MAP), systolic, and diastolic pressures increased about 20 percent in HDT rats on the fist day, heart rates were elevated about 10 percent. During postsuspension most cardiovascular parameters returned to presuspension levels. The second experiment evaluated responses to rapid head-up tilt in HDT and NHDT rats. It was observed that, while pulse pressures remained unchanged, MAP, systolic and diastolic pressures, and HR were elevated in HDT and NHDT rats during head-up tilt after one day of suspension. The WBS rats are considered to be useful as a model to better understand responses of rats exposed to microgravity.

  4. Rat Cardiovascular Responses to Whole Body Suspension: Head-down and Non-Head-Down Tilt

    Science.gov (United States)

    Musacchia, X. J.; Steffen, Joseph M.; Dombrowski, Judy

    1992-01-01

    The rat whole body suspension technique mimics responses seen during exposure to microgravity and was evaluated as a model for cardiovascular responses with two series of experiments. In one series, changes were monitored in chronically catheterized rats during 7 days of Head-Down Tilt (HDT) or Non-Head-Down Tilt (N-HDT) and after several hours of recovery. Elevations of mean arterial (MAP), systolic, and diastolic pressures of approx. 20 % (P less than 0.05) in HDT rats began as early as day 1 and were maintained for the duration of suspension. Pulse pressures were relatively unaffected, but heart rates were elevated approx. 10 %. During postsuspension (2-7 h), most cardiovascular parameters returned to presuspension levels. N-HDT rats exhibited elevations chiefly on days 3 and 7. In the second series, blood pressure was monitored in 1- and 3-day HDT and N-HDT rats to evaluate responses to rapid head-up tilt. MAP, systolic and diastolic pressures, and HR were elevated (P less than 0.05) in HDT and N-HDT rats during head-up tilt after 1 day of suspension, while pulse pressures remained un changed. HDT rats exhibited elevated pretilt MAP and failed to respond to rapid head-up tilt with further increase of MAP on day 3, indicating some degree of deconditioning. The whole body suspended rat may be useful as a model to better understand responses of rats exposed to microgravity.

  5. Progressive resistance, whole body long-axis rotational training improves kicking motion motor performance.

    Science.gov (United States)

    Nyland, John; Love, Matthew; Burden, Robert; Krupp, Ryan; Caborn, David N M

    2014-02-01

    To evaluate lower extremity muscle activation, peak resultant ground reaction force (GRF) production and quickness during performance of a kicking motion following progressive resistance, whole body long-axis rotational training. Randomized, controlled study. Kinesiological research laboratory. Thirty-six healthy subjects were assigned to a training (Group 1) or to a control (Group 2) group. Time-synchronized EMG (1000 Hz), peak resultant GRF (1000 Hz) and two-dimensional kinematic (60 Hz) data were collected as subjects responded to an audio cue by kicking a cone. Group mean change differences (MCD) were compared using independent sample t-tests. Fisher's exact tests were used to determine group differences in the proportion of subjects that displayed earlier activation responses post-training. Group 1 MCD revealed earlier gluteus maximus, gluteus medius, rectus femoris, medial hamstrings, and biceps femoris activation timing than Group 2 (P ≤ 0.006) and more Group 1 subjects displayed earlier activation of these muscles post-training (P ≤ 0.041). Group 1 MCD also revealed earlier peak resultant GRF timing and improved "kick quickness" than Group 2 (P ≤ 0.014) and more Group 1 subjects displayed earlier response timing for these variables post-training (P = 0.035). Progressive resistance, whole body long-axis rotational training may improve performance during sports movements that require quick, integrated trunk-lower extremity function. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Whole-body vibration training effects on the physical performance of basketball players.

    Science.gov (United States)

    Colson, Serge S; Pensini, Manuela; Espinosa, Julien; Garrandes, Frederic; Legros, Patrick

    2010-04-01

    The aim of this study was to investigate the influence of 4 weeks of whole-body vibration training added to the conventional training of basketball players. Eighteen competitive basketball players (13 male symbol, 5 female symbol, 18-24 years old) were randomly assigned to a whole-body vibration group (WBVG, n = 10; 7 male symbol and 3 female symbol) or a control group (CG, n = 8; 6 male symbol and 2 female symbol). During the 4-week period, all subjects maintained their conventional basketball training program. The members of WBVG were additionally trained 3 times a week for 20 minutes on a vibration platform (10 unloaded static lower limb exercises, 40-Hz, 4-mm, Silverplate). Testing was performed before and after the 4-week period and comprised strength assessment, vertical jump performance, and a 10-m sprint test. The maximal voluntary isometric strength of the knee extensors significantly increased (p training, as did squat jump (SJ) height (p training program added to the conventional training of basketball players during the preseason is an effective short-term stimulus to enhance knee extensor strength and slightly SJ performance.

  7. Estimation of throium deposited in thorotrast patients by whole body counter

    International Nuclear Information System (INIS)

    Tatsumi-Miyajima, Junko; Okajima, Shunzo; Takao, Hideaki; Norimura, Toshiyuki.

    1986-01-01

    Thorotrast, a colloidal solution of thorium dioxide was injected to wounded soldiers, for angiography from 1930 to 1945. The patients who received Thorotrast are interesting objects for finding a biological effect due to the internal irradiation by 232 Th. To determine a distribution and body burden of 232 Th, forty-one Thorotrast patients were measured their gamma-rays with a pair of NaI(T1) scintillation detectors coaxially positioned above and below the coach in the whole body counter of Nagasaki University. The comparison between the usual method using constant values and the method using individual values depend on the organ positions determined with CT (Computed Tomography) scanner for patients was performed to estimate the errors due to the individual differences in the detection efficiency of 232 Th. From the results, the estimates by the whole body counter of the amounts of 232 Th deposits in abdominal region were obtained within the uncertainties of 16 %. And the absorbed dose in the liver and the spleen was also estimated from the amounts of 232 Th. (author)

  8. Dynamic whole body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    Science.gov (United States)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-01-01

    Static whole body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single bed-coverage limiting the axial field-of-view to ~15–20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole body PET acquisition protocol of ~45min total length is presented, composed of (i) an initial 6-min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (6 passes x 7 bed positions, each scanned for 45sec). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares (OLS) Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of 10 different clinically

  9. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Tahari, Abdel K; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ~15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ~45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically

  10. Local forearm and whole-body respiratory quotient in humans after an oral glucose load: methodological problems

    DEFF Research Database (Denmark)

    Simonsen, L; Bülow, J; Madsen, Jan Lysgård

    1993-01-01

    The effects of an oral glucose load of 75 g on the local forearm and whole-body energy thermogenesis were measured in normal subjects during the 4 h after the glucose intake. Simultaneous assessment of substrate metabolism in the forearm was performed. Energy expenditure (EE) increased after.......17) to 0.63 (0.17) 30 min after the glucose load (P problems in the measurement of local forearm RQ. The whole-body RQ...

  11. The effects of visual control whole body vibration exercise on balance and gait function of stroke patients

    OpenAIRE

    Choi, Eon-Tak; Kim, Yong-Nam; Cho, Woon-Soo; Lee, Dong-Kyu

    2016-01-01

    [Purpose] This study aims to verify the effects of visual control whole body vibration exercise on balance and gait function of stroke patients. [Subjects and Methods] A total of 22 stroke patients were randomly assigned to two groups; 11 to the experimental group and 11 to the control group. Both groups received 30 minutes of Neuro-developmental treatment 5 times per week for 4 weeks. The experimental group additionally performed 10 minutes of visual control whole body vibration exercise 5 t...

  12. Effects of local and whole body irradiation on appearance of osteoclasts during wound healing of tooth extraction sockets in rats

    International Nuclear Information System (INIS)

    Hosokawa, Yoichiro; Sakakura, Yasunori; Tanaka, Likinobu; Okumura, Kazuhiko; Yajima, Toshihiko; Kaneko, Masayuki

    2007-01-01

    We examined effects of local and whole body irradiation before tooth extraction on appearance and differentiation of osteoclasts in the alveolar bone of rat maxillary first molars. Wistar rats weighting 100 g were divided into three groups: non-irradiation group, local irradiation group, and whole body irradiation group. In the local irradiation group, a field made with lead blocks was placed over the maxillary left first molar tooth. In the whole body irradiation group, the animals were irradiated in cages. Both groups were irradiated at 8 Gy. The number of osteoclasts around the interradicular alveolar bone showed chronological changes common to non-irradiated and irradiated animals. Several osteoclasts appeared one day after tooth extraction, and the maximal peak was observed 3 days after extraction. Local irradiation had no difference from non-irradiated controls. In animals receiving whole body irradiation, tooth extraction one day after irradiation caused smaller number of osteoclasts than that 7 day after irradiation during the experimental period. Whole body-irradiated rats had small osteoclasts with only a few nuclei and narrow resorption lacunae, indicating deficiency of radioresistant osteoclast precursor cells. Injection of intact bone marrow cells to whole body-irradiated animals immediately after tooth extraction recovered to some content the number of osteoclasts. These findings suggest that bone resorption in the wound healing of alveolar socket requires radioresistant, postmitotic osteoclast precursor cells from hematopoietic organs, but not from local sources around the alveolar socket, at the initial phase of wound healing. (author)

  13. Effects of local and whole body irradiation on appearance of osteoclasts during wound healing of tooth extraction sockets in rats.

    Science.gov (United States)

    Hosokawa, Yoichiro; Sakakura, Yasunori; Tanaka, Likinobu; Okumura, Kazuhiko; Yajima, Toshihiko; Kaneko, Masayuki

    2007-07-01

    We examined effects of local and whole body irradiation before tooth extraction on appearance and differentiation of osteoclasts in the alveolar bone of rat maxillary first molars. Wistar rats weighting 100 g were divided into three groups: non-irradiation group, local irradiation group, and whole body irradiation group. In the local irradiation group, a field made with lead blocks was placed over the maxillary left first molar tooth. In the whole body irradiation group, the animals were irradiated in cages. Both groups were irradiated at 8 Gy. The number of osteoclasts around the interradicular alveolar bone showed chronological changes common to non-irradiated and irradiated animals. Several osteoclasts appeared one day after tooth extraction, and the maximal peak was observed 3 days after extraction. Local irradiation had no difference from non-irradiated controls. In animals receiving whole body irradiation, tooth extraction one day after irradiation caused smaller number of osteoclasts than that 7 day after irradiation during the experimental period. Whole body-irradiated rats had small osteoclasts with only a few nuclei and narrow resorption lacunae, indicating deficiency of radioresistant osteoclast precursor cells. Injection of intact bone marrow cells to whole body-irradiated animals immediately after tooth extraction recovered to some content the number of osteoclasts. These findings suggest that bone resorption in the wound healing of alveolar socket requires radioresistant, postmitotic osteoclast precursor cells from hematopoietic organs, but not from local sources around the alveolar socket, at the initial phase of wound healing.

  14. A Comparison of Molecular and Histopathological Changes in Mouse Intestinal Tissue Following Whole-Body Proton- or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Mangala, Lingegowda; Zhang, Ye; Hamilton, Stanley; Wu, Honglu

    2010-01-01

    There are many consequences following exposure to the space radiation environment which can adversely affect the health of a crew member. Acute radiation syndrome (ARS) involving nausea and vomiting, damage to radio-sensitive tissue such as the blood forming organs and gastrointestinal tract, and cancer are some of these negative effects. The space radiation environment is ample with protons and contains gamma rays as well. Little knowledge exists to this point, however, regarding the effects of protons on mammalian systems; conversely several studies have been performed observing the effects of gamma rays on different animal models. For the research presented here, we wish to compare our previous work looking at whole-body exposure to protons using a mouse model to our studies of mice experiencing whole-body exposure to gamma rays as part of the radio-adaptive response. Radio-adaptation is a well-documented phenomenon in which cells exposed to a priming low dose of radiation prior to a higher dose display a reduction in endpoints like chromosomal aberrations, cell death, micronucleus formation, and more when compared to their counterparts receiving high dose-irradiation only. Our group has recently completed a radio-adaptive experiment with C57BL/6 mice. For both this study and the preceding proton research, the gastrointestinal tract of each animal was dissected four hours post-irradiation and the isolated small intestinal tissue was fixed in formalin for histopathological examination or snap-frozen in liquid nitrogen for RNA isolation. Histopathologic observation of the tissue using standard H&E staining methods to screen for morphologic changes showed an increase in apoptotic lesions for even the lowest doses of 0.1 Gy of protons and 0.05 Gy of gamma rays, and the percentage of apoptotic cells increased with increasing dose. A smaller percentage of crypts showed 3 or more apoptotic lesions in animals that received 6 Gy of gamma-irradiation compared to mice

  15. Whole-body MRI in patients with Non-bacterial Osteitis: Radiological findings and correlation with clinical data

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldi, A.P.; Geyer, L.L. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital, Munich (Germany); Schlett, C.L.; Weckbach, S. [University Hospital Heidelberg, Diagnostic and Interventional Radiology, Heidelberg (Germany); Douis, H. [University Hospital Birmingham, Department of Radiology, Birmingham (United Kingdom); Voit, A.M.; Bleisteiner, F.; Jansson, A.F. [Dr. von Hauner Children' s Hospital, Ludwig-Maximilians-University, Department of Rheumatology and Immunology, Munich (Germany)

    2017-06-15

    To correlate clinical findings of Non-bacterial Osteitis (NBO) with whole-body MRI (WB-MRI) findings and determine a radiologic index for NBO (RINBO) which allows standardized reporting of WB-MRI. In a prospective study, 40 patients with diagnosis of NBO underwent clinical examination and WB-MRI in which STIR- and T1- weighted images were assessed for NBO-typical lesions. Parameters of interest for RINBO were: number of radiologically active lesions (RAL), size of the patients' maximum RAL presence of extramedullary and spinal involvement. Results were tested for statistical agreement of clinical and MR-based lesion detection. RINBO was tested for correlation with clinical activity. 62/95 clinically/radiologically active lesions were found in 30/33 patients. In 45 % of the cohort, more active lesions were detected by WB-MRI than by clinical examination. RINBO was a significant predictor for the presence of clinically active lesions. WB-MRI is a powerful diagnostic tool for patients with NBO which can reveal asymptomatic disease activity. With RINBO a standardized evaluation approach is proposed which helps assessing radiologic disease burden and predicts clinical disease activity. (orig.)

  16. A high-resolution imaging technique using a whole-body, research photon counting detector CT system

    Science.gov (United States)

    Leng, S.; Yu, Z.; Halaweish, A.; Kappler, S.; Hahn, K.; Henning, A.; Li, Z.; Lane, J.; Levin, D. L.; Jorgensen, S.; Ritman, E.; McCollough, C.

    2016-03-01

    A high-resolution (HR) data collection mode has been introduced to a whole-body, research photon-counting-detector CT system installed in our laboratory. In this mode, 64 rows of 0.45 mm x 0.45 mm detector pixels were used, which corresponded to a pixel size of 0.25 mm x 0.25 mm at the iso-center. Spatial resolution of this HR mode was quantified by measuring the MTF from a scan of a 50 micron wire phantom. An anthropomorphic lung phantom, cadaveric swine lung, temporal bone and heart specimens were scanned using the HR mode, and image quality was subjectively assessed by two experienced radiologists. High spatial resolution of the HR mode was evidenced by the MTF measurement, with 15 lp/cm and 20 lp/cm at 10% and 2% modulation. Images from anthropomorphic phantom and cadaveric specimens showed clear delineation of small structures, such as lung vessels, lung nodules, temporal bone structures, and coronary arteries. Temporal bone images showed critical anatomy (i.e. stapes superstructure) that was clearly visible in the PCD system. These results demonstrated the potential application of this imaging mode in lung, temporal bone, and vascular imaging. Other clinical applications that require high spatial resolution, such as musculoskeletal imaging, may also benefit from this high resolution mode.

  17. Acute non-stochastic effect of very low dose whole-body exposure, a thymidine equivalent serum factor

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; Muehlensiepen, H.; Porschen, W.; Booz, J.

    1982-01-01

    Whole-body irradiation of mice causes the dose-dependent appearance of a humoral factor in blood serum which inhibits incorporation of 125-IUdR into tissue culture cells. This factor appears even at doses below 0.01 Gy gamma irradiation and thus is probably not related to cell death. Data are presented relating this humoral factor to thymidine. Since at low doses the target size for this effect was calculated to be the entire cell, a cellular effect is postulated linking the site of few primary absorption events, anywhere in the cell, with the cellular membrane, thus causing changes in membrane charge, structure and/or fluidity. This may lead to blocking thymidine acceptance by the cell, and thus would cause a pile-up of thymidine in the reutilization pathway in peripheral blood and would give rise to the observed effect. The effect appears as a temporary disturbance of the physiological equilibrium and should not be related at present to any cellular damage. The acute low-dose effect described has implications for the measurement of low-dose exposure by biological dosimeters and on basic research on membrane function. (author)

  18. Using a whole body counter to attract a younger generation to radiation and radiation protection topics

    International Nuclear Information System (INIS)

    Breustedt, B.; Mohr, U.; Bohnstedt, A.; Knebel, J.U.

    2010-01-01

    Currently there is a lack of young academics in the nuclear field especially in the field of radiation protection RP. One of the reasons is the very small number of students in the so called STEM subjects (science, technology, engineering and mathematics) which distribute among the different topics in these fields. One important task to overcome the foreseeable shortage of RP professionals is to attract pupils to this field. In routine monitoring the whole body counter of the Institute of Radiation Research (ISF) is used to identify and quantify radioactive materials that are incorporated in the human body using the technique of gamma spectroscopy. The in-vivo monitoring lab participates in activities for pupils at school level, e.g. Kinderuniversitaet, practical studies of secondary level pupils and 'Girls day'. Pupils that come to the lab are ages 14 to 18. The whole body counter is an optimal tool for these children to experience (natural) radioactivity and radiation protection issues. First pupils get a short introduction on radioactivity and gamma spectroscopy at a level adjusted to their current knowledge. After this they are measuring themselves in the whole body counter. A routine measurement of 300 s is able to show the natural occurring K-40 in their bodies. After their own measurements they do calibration measurements using a bottle phantom with a set up adjusted to their own body weights. The bottle phantom is filled with a potassium chloride (KCl) solution and contains no other radioactivity than the natural K-40 content of the KCl. Thus no further radiation protection measures need to be taken for using this phantom. A simple Excel-Sheet is then used to estimate their own K-40 activity by comparing the spectra of their measurement to the ones of the calibration measurements. This 'hands on' experience and the connection of radiation and their own bodies often is a 'eureka' effect and opens discussion on preconceptions of radiation and the need of RP

  19. Whole body protein kinetics measured with a non-invasive method in severely burned children.

    Science.gov (United States)

    Børsheim, Elisabet; Chinkes, David L; McEntire, Serina J; Rodriguez, Nancy R; Herndon, David N; Suman, Oscar E

    2010-11-01

    Persistent and extensive skeletal muscle catabolism is characteristic of severe burns. Whole body protein metabolism, an important component of this process, has not been measured in burned children during the long-term convalescent period. The aim of this study was to measure whole body protein turnover in burned children at discharge (95% healed) and in healthy controls by a non-invasive stable isotope method. Nine burned children (7 boys, 2 girls; 54±14 (S.D.)% total body area burned; 13±4 years; 45±20 kg; 154±14 cm) and 12 healthy children (8 boys, 4 girls; 12±3 years; 54±16 kg; 150±22 cm) were studied. A single oral dose of (15)N-alanine (16 mg/kg) was given, and thereafter urine was collected for 34 h. Whole body protein flux was calculated from labeling of urinary urea nitrogen. Then, protein synthesis was calculated as protein flux minus excretion, and protein breakdown as flux minus intake. At discharge, total protein turnover was 4.53±0.65 (S.E.)g kg body weight(-1) day(-1) in the burned children compared to 3.20±0.22 g kg(-1) day(-1) in controls (P=0.02). Expressed relative to lean body mass (LBM), the rates were 6.12±0.94 vs. 4.60±0.36 g kg LBM(-1) day(-1) in burn vs. healthy (P=0.06). Total protein synthesis was also elevated in burned vs. healthy children, and a tendency for elevated protein breakdown was observed. Total protein turnover is elevated in burned children at discharge compared to age-matched controls, possibly reflecting the continued stress response to severe burn. The oral (15)N-alanine bolus method is a convenient, non-invasive, and no-risk method for measurement of total body protein turnover. Copyright © 2010 Elsevier Ltd and ISBI. All rights reserved.

  20. Factors affecting gastric uptake in whole body FDG-PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi [Nishidai Clinic Diagnostic Imaging Center, Tokyo (Japan)

    2001-06-01

    Positron emission tomography (PET) using 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects

  1. Factors affecting gastric uptake in whole body FDG-PET imaging

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi

    2001-01-01

    Positron emission tomography (PET) using 2-deoxy-2-[ 18 F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects with high

  2. Estimation of normal hydration in dialysis patients using whole body and calf bioimpedance analysis

    International Nuclear Information System (INIS)

    Zhu, Fansan; Kotanko, Peter; Handelman, Garry J; Raimann, Jochen G; Liu, Li; Carter, Mary; Kuhlmann, Martin K; Seibert, Eric; Levin, Nathan W; Leonard, Edward F

    2011-01-01

    Prescription of an appropriate dialysis target weight (dry weight) requires accurate evaluation of the degree of hydration. The aim of this study was to investigate whether a state of normal hydration (DW cBIS ) as defined by calf bioimpedance spectroscopy (cBIS) and conventional whole body bioimpedance spectroscopy (wBIS) could be characterized in hemodialysis (HD) patients and normal subjects (NS). wBIS and cBIS were performed in 62 NS (33 m/29 f) and 30 HD patients (16 m/14 f) pre- and post-dialysis treatments to measure extracellular resistance and fluid volume (ECV) by the whole body and calf bioimpedance methods. Normalized calf resistivity (ρ N,5 ) was defined as resistivity at 5 kHz divided by the body mass index. The ratio of wECV to total body water (wECV/TBW) was calculated. Measurements were made at baseline (BL) and at DW cBIS following the progressive reduction of post-HD weight over successive dialysis treatments until the curve of calf extracellular resistance is flattened (stabilization) and the ρ N,5 was in the range of NS. Blood pressures were measured pre- and post-HD treatment. ρ N,5 in males and females differed significantly in NS. In patients, ρ N,5 notably increased with progressive decrease in body weight, and systolic blood pressure significantly decreased pre- and post-HD between BL and DW cBIS respectively. Although wECV/TBW decreased between BL and DW cBIS , the percentage of change in wECV/TBW was significantly less than that in ρ N,5 (−5.21 ± 3.2% versus 28 ± 27%, p < 0.001). This establishes the use of ρ N,5 as a new comparator allowing a clinician to incrementally monitor removal of extracellular fluid from patients over the course of dialysis treatments. The conventional whole body technique using wECV/TBW was less sensitive than the use of ρ N,5 to measure differences in body hydration between BL and DW cBIS

  3. A method for exposing rodents to resuspended particles using whole-body plethysmography

    Directory of Open Access Journals (Sweden)

    Nolan Julianne P

    2006-08-01

    Full Text Available Abstract Background Epidemiological studies have reported increased risks of cardiopulmonary-related hospitalization and death in association with exposure to elevated levels of particulate matter (PM across a wide range of urban areas. In response to these findings, researchers have conducted animal inhalation exposures aimed at reproducing the observed toxicologic effects. However, it is technically difficult to quantitate the actual amount of PM delivered to the lung in such studies, and dose is frequently estimated using default respiration parameters. Consequently, the interpretation of PM-induced effects in rodents exposed via whole-body inhalation is often compromised by the inability to determine deposited dose. To address this problem, we have developed an exposure system that merges the generation of dry, aerosolized particles with whole-body plethysmography (WBP, thus permitting inhalation exposures in the unrestrained rat while simultaneously obtaining data on pulmonary function. Results This system was validated using an oil combustion-derived particle (HP12 at three nominal concentrations (3, 12, and 13 mg/m3 for four consecutive exposure days (6 hr/day; a single 6-hour exposure to 13 mg/m3 of HP12 was also conducted. These results demonstrated that the system was both reliable and consistent over these exposure protocols, achieving average concentrations that were within 10% of the targeted concentration. In-line filters located on the exhaust outlets of individual WBP chambers showed relative agreement in HP12 mass for each day and were not statistically different when compared to one another (p = 0.16. Temperatures and relative humidities were also similar between chambers during PM and air exposures. Finally, detailed composition analyses of both HP12 filter and bulk samples showed that grinding and aerosolization did not change particle chemistry. Conclusion The results of this study demonstrate that it is possible to expose

  4. Evaluation of diagnostic performance of whole-body simultaneous PET/MRI in pediatric lymphoma

    International Nuclear Information System (INIS)

    Ponisio, Maria Rosana; Laforest, Richard; Khanna, Geetika; McConathy, Jonathan

    2016-01-01

    Whole-body 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is the standard of care for lymphoma. Simultaneous PET/MRI (magnetic resonance imaging) is a promising new modality that combines the metabolic information of PET with superior soft-tissue resolution and functional imaging capabilities of MRI while decreasing radiation dose. There is limited information on the clinical performance of PET/MRI in the pediatric setting. This study evaluated the feasibility, dosimetry, and qualitative and quantitative diagnostic performance of simultaneous whole-body FDG-PET/MRI in children with lymphoma compared to PET/CT. Children with lymphoma undergoing standard of care FDG-PET/CT were prospectively recruited for PET/MRI performed immediately after the PET/CT. Images were evaluated for quality, lesion detection and anatomical localization of FDG uptake. Maximum and mean standardized uptake values (SUV max/mean ) of normal organs and SUV max of the most FDG-avid lesions were measured for PET/MRI and PET/CT. Estimation of radiation exposure was calculated using specific age-related factors. Nine PET/MRI scans were performed in eight patients (mean age: 15.3 years). The mean time interval between PET/CT and PET/MRI was 51 ± 10 min. Both the PET/CT and PET/MRI exams had good image quality and alignment with complete (9/9) concordance in response assessment. The SUVs from PET/MRI and PET/CT were highly correlated for normal organs (SUV mean r 2 : 0.88, P<0.0001) and very highly for FDG-avid lesions (SUV max r 2 : 0.94, P=0.0002). PET/MRI demonstrated an average percent radiation exposure reduction of 39% ± 13% compared with PET/CT. Simultaneous whole-body PET/MRI is clinically feasible in pediatric lymphoma. PET/MRI performance is comparable to PET/CT for lesion detection and SUV measurements. Replacement of PET/CT with PET/MRI can significantly decrease radiation dose from diagnostic imaging in children. (orig.)

  5. Gene Expression Changes in Mouse Intestinal Tissue Following Whole-Body Proton or Gamma-Irradiation

    Science.gov (United States)

    Purgason, Ashley; Zhang, Ye; Mangala, Lingegowda; Nie, Ying; Gridley, Daila; Hamilton, Stanley R.; Seidel, Derek V.; Wu, Honglu

    2014-01-01

    Crew members face potential consequences following exposure to the space radiation environment including acute radiation syndrome and cancer. The space radiation environment is ample with protons, and numerous studies have been devoted to the understanding of the health consequences of proton exposures. In this project, C57BL/6 mice underwent whole-body exposure to 250 MeV of protons at doses of 0, 0.1, 0.5, 2 and 6 Gy and the gastrointestinal (GI) tract of each animal was dissected four hours post-irradiation. Standard H&E staining methods to screen for morphologic changes in the tissue showed an increase in apoptotic lesions for even the lowest dose of 0.1 Gy, and the percentage of apoptotic cells increased with increasing dose. Results of gene expression changes showed consistent up- or down- regulation, up to 10 fold, of a number of genes across exposure doses that may play a role in proton-induced oxidative stress including Gpx2. A separate study in C57BL/6 mice using the same four hour time point but whole-body gamma-irradiation showed damage to the small intestine with lesions appearing at the smallest dose of 0.05 Gy and increasing with increasing absorbed dose. Expressions of genes associated with oxidative stress processes were analyzed at four hours and twenty-four hours after exposure to gamma rays. We saw a much greater number of genes with significant up- or down-regulation twenty-four hours post-exposure as compared to the four hour time point. At both four hours and twenty-four hours post-exposure, Duox1 and Mpo underwent up-regulation for the highest dose of 6 Gy. Both protons and gamma rays lead to significant variation in gene expressions and these changes may provide insight into the mechanism of injury seen in the GI tract following radiation exposure. We have also completed experiments using a BALB/c mouse model undergoing whole-body exposure to protons. Doses of 0, 0.1, 1 and 2 Gy were used and results will be compared to the work mentioned

  6. Whole-body FDG-PET/CT on rheumatoid arthritis of large joints

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Morooka, Miyako; Mitsumoto, Takuya; Kurihara, Kyoko; Yamashita, Hiroyuki; Takahashi, Yuko; Mimori, Akio; Ito, Kimiteru

    2009-01-01

    Fluorodeoxyglucose (FDG) uptake in joint lesions in patients with rheumatoid arthritis (RA) reportedly represents the degree of synovial inflammation. Most previous studies have focused on small joints, and the application of whole-body positron emission tomography (PET) combined with computed tomography (CT) (PET/CT) for the evaluation of inflammatory activity in large joints has not been well studied. Eighteen patients with RA underwent FDG-PET/CT. FDG uptake in the knee, hip, carpal, wrist, elbow, shoulder, and atlanto-axial joint (total of 13 joints) and in the axillary lymph nodes was evaluated by calculating the maximum standardized uptake value (SUV max ) and the visual uptake scores as follows: 0, no uptake; 1, slight uptake; 2, moderate uptake (same as in liver); 3, higher than in liver; 4, highest uptake. The number of painful/swollen joints, the white blood cell (WBC) count, and the C-reactive protein (CRP) level were also evaluated. Whole-body FDG-PET/CT delineated large-joint lesions in patients with RA, and the metabolic activity of inflammation was accurately overlaid on the joint anatomy. The total FDG score for all 13 joints was significantly correlated with the CRP level (r=0.653, p max and the CRP level were weakly, but not significantly, correlated (r=0.377, p>0.05). The WBC count was not correlated with any other parameter. The mean number of joints per patient with an FDG uptake score of 2 or more was significantly larger than the mean number of painful/swollen joints (6.2±3.3 vs. 3.1±2.7, n=18, p<0.01) and both parameters were strongly correlated (r=0.588, p<0.01, n=18). Also, FDG uptake score and SUV of painful/swollen joints were significantly higher than these of not painful/swollen joints. FDG uptake was significantly different from patients of remission and patients of active arthritis. Uptake in the atlanto-axial joint was observed in five (mostly asymptomatic) patients (5/18, 28%), and the uptake score was significantly correlated

  7. Finite-size effects in transcript sequencing count distribution: its power-law correction necessarily precedes downstream normalization and comparative analysis.

    Science.gov (United States)

    Wong, Wing-Cheong; Ng, Hong-Kiat; Tantoso, Erwin; Soong, Richie; Eisenhaber, Frank

    2018-02-12

    Though earlier works on modelling transcript abundance from vertebrates to lower eukaroytes have specifically singled out the Zip's law, the observed distributions often deviate from a single power-law slope. In hindsight, while power-laws of critical phenomena are derived asymptotically under the conditions of infinite observations, real world observations are finite where the finite-size effects will set in to force a power-law distribution into an exponential decay and consequently, manifests as a curvature (i.e., varying exponent values) in a log-log plot. If transcript abundance is truly power-law distributed, the varying exponent signifies changing mathematical moments (e.g., mean, variance) and creates heteroskedasticity which compromises statistical rigor in analysis. The impact of this deviation from the asymptotic power-law on sequencing count data has never truly been examined and quantified. The anecdotal description of transcript abundance being almost Zipf's law-like distributed can be conceptualized as the imperfect mathematical rendition of the Pareto power-law distribution when subjected to the finite-size effects in the real world; This is regardless of the advancement in sequencing technology since sampling is finite in practice. Our conceptualization agrees well with our empirical analysis of two modern day NGS (Next-generation sequencing) datasets: an in-house generated dilution miRNA study of two gastric cancer cell lines (NUGC3 and AGS) and a publicly available spike-in miRNA data; Firstly, the finite-size effects causes the deviations of sequencing count data from Zipf's law and issues of reproducibility in sequencing experiments. Secondly, it manifests as heteroskedasticity among experimental replicates to bring about statistical woes. Surprisingly, a straightforward power-law correction that restores the distribution distortion to a single exponent value can dramatically reduce data heteroskedasticity to invoke an instant increase in

  8. The effect of whole body irradiation on the action of strong analgesics of mice

    International Nuclear Information System (INIS)

    Cvetkovicj, M.; Milovanovicj, A.; Tanasijevicj, D.

    1987-01-01

    The effect of whole body irradiation of male mice with single doses of 3 and 7 Gy ( 60 Co source) on analgesic action of three morphine-like drugs was studied. Over the first 6 days after irradiation, the analgesic effect of alfentanil and fentanyl was significantly less pronounced in irradiated animals than in control ones. During the subsequent period of 24 days till the end of experiment, the analgesic effect in irradiated animals gradually increased reaching and exceeding the control values. On the contrary, the analgesic effect of butorphanole was less pronounced in irradiated animals than in control ones, although the difference was not significantly. The difference between butorphanole and other two drugs are probably due to chemical structure and the metabolic fate in the body. (author) 8 refs.; 2 figs

  9. Thymic nurse cells and thymic repopulation after whole body sublethal irradiation in mice

    International Nuclear Information System (INIS)

    Houben-Defresne, M.P.; Varlet, A.; Boniver, J.

    1984-01-01

    Thymic Nurse Cells (TNCs) are lymphoepithelial complexes which are thought to play a role in the early stages of the intrathymic differentiation pathway. Their repopulation kinetics were analyzed in mice after sublethal whole-body irradiation. Changes of the number of TNCs per thymus were parallel with the evolution of the whole thymocyte population. Particularly, a first wave of TNCs restoration was followed by a secondary depletion and a final recovery. This suggests that TNCs restoration is related to the proliferating progeny of intrathymic radioresistant thymocytes. When normal bone marrow cells were grafted intravenously after irradiation, no secondary depletion was found. This pattern of restoration was obviously related to thymic repopulation by cells which were derived from the inoculated bone marrow. Homing studies with FITC labelled bone marrow cells showed that inoculated bone marrow cells did not penetrate TNCs early after irradiation. Later on, when immigrant cells started to proliferate, they were found preferentially within TNCs before spreading in the whole thymus. (Auth.)

  10. Whole body X-ray CT scanner SCT-3000T series

    International Nuclear Information System (INIS)

    Saida, Teruhiko; Takemura, Kunihiko; Suzuki, Satoru; Sato, Yukio; Kawamoto, Yasushi; Goto, Mitsuhiro; Mishina, Yukio

    1989-01-01

    The whole body CT scanner, SCT-3000T series which improve the patient through-put and the diagnostic capability, has been developed. In the SCT-3000T series CT scanners, the great reduction of the reconstruction time and the scan cycle time has been achieved by developing the special purpose hardwares for image reconstruction such as the fast front end processor, the intelligent buffer memory. In case of the SCT-3000TX routine conditions of operation, including 3.0 sec scan, table increment, image reconstruction and image filing, the scan cycle time is about 9 seconds which is the shortest value among the competitive models. Furthermore, the higher diagnostic capability has been provided with the system, by adopting the 1024 x 1024 display matrices, and by developing the diagnostic softwares such as 3-D display program, arbitrary curved plane MPR program, r-CBF measurement program and etc. (author)

  11. The modes of death in mammals exposed to whole body radiation (acute radiation syndromes)

    International Nuclear Information System (INIS)

    Santos, O.R. dos.

    1990-07-01

    When an animal is exposed to a sufficient amount of radiation, there will be changes in many organs of the body, and as a result of either the effects in one particular organ or the interaction of effects in several organs, the animal as a whole will show characteristic syndromes. Some syndromes result inevitably in death. Others may or may not be lethal, depending on the extent of the tissue damage. The time of appearance of the syndromes, their duration, and the survival of the organism depend on many factors. Whole body acute doses of radiation produce the same spectrum of Central Nervous System (CNS), Gastrointestinal (GI) and Bone Marrow (BM) injury in man as was described for animals. Damage to the skin, ovary and testis are an integral and important part of the symptoms. (author) [pt

  12. Aerobic Exercise and Whole-Body Vibration in Offsetting Bone Loss in Older Adults

    Directory of Open Access Journals (Sweden)

    Pei-Yang Liu

    2011-01-01

    Full Text Available Osteoporosis and its associated fractures are common complications of aging and most strategies to prevent and/or treat bone loss focused on antiresorptive medications. However, aerobic exercise (AEX and/or whole-body vibration (WBV might have beneficial effect on bone mass and provide an alternative approach to increase or maintain bone mineral density (BMD and reduce the risk of fractures. The purpose of this paper was to investigate the potential benefits of AEX and WBV on BMD in older population and discuss the possible mechanisms of action. Several online databases were utilized and based on the available literature the consensus is that both AEX and WBV may increase spine and femoral BMD in older adults. Therefore, AEX and WBV could serve as nonpharmacological and complementary approaches to increasing/maintaining BMD. However, it is uncertain if noted effects could be permanent and further studies are needed to investigate sustainability of either type of the exercise.

  13. Effect of whole-body vibration exercise in preventing falls and fractures

    DEFF Research Database (Denmark)

    Jepsen, Ditte Beck; Thomsen, Katja; Hansen, Stinus

    2017-01-01

    of retrieved publications. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Randomised controlled trials examining the effect of WBV on fracture risk in adults ≥50 years of age. The primary outcomes were fractures, fall rates and the proportion of participants who fell. Secondary outcomes were bone mineral density......OBJECTIVE: To investigate the effect of whole-body vibration exercise (WBV) on fracture risk in adults ≥50 years of age. DESIGN: A systematic review and meta-analysis calculating relative risk ratios, fall rate ratio and absolute weighted mean difference using random effects models. Heterogeneity...... (BMD), bone microarchitecture, bone turnover markers and calcaneal broadband attenuation (BUA). RESULTS: 15 papers (14 trials) met the inclusion criteria. Only one study had fracture data reporting a non-significant fracture reduction (risk ratio (RR)=0.47, 95% CI 0.14 to 1.57, P=0.22) (moderate...

  14. Whole-body autoradiography of 63Ni in mice throughout gestation

    International Nuclear Information System (INIS)

    Olsen, I.; Jonsen, J.

    1979-01-01

    Whole-body autoradiography was used to study nickel uptake and retention in mice throughout gestation. After an intraperitoneal injection of 50μCi 63 NiCl 2 into a 16-day-pregnant mouse, nickel appeared rapidly in connective tissues. Prominent sites of radioactivity 72 h after injection included the visceral yolk sac, lung, gastrointestinal tract and kidney. Nickel crossed the placental barriers throughout gestation, i.e. the visceral yolk sac during early gestation, the visceral yolk sac and chorioallantoic placenta during late gestation. A marked uptake of nickel was seen already in the 5-and 6-day embryo. Fetal accumulation of nickel took place up to 16 days gestation. Whereas nickel was distributed throughout the early embryo, distribution became more differentiated with increasing gestation, imitating that in the mother. Penetration of nickel into the mouse conceptus makes possible a similar ability in the human conceptus. (author)

  15. Whole body exposure to low-dose γ-radiation enhances the antioxidant defense system

    International Nuclear Information System (INIS)

    Pathak, C.M.; Avti, P.K.; Khanduja, K.L.; Sharma, S.C.

    2008-01-01

    It is believed that the extent of cellular damage by low- radiation dose is proportional to the effects observed at high radiation dose as per the Linear-No-Threshold (LNT) hypothesis. However, this notion may not be true at low-dose radiation exposure in the living system. Recent evidence suggest that the living organisms do not respond to ionizing radiations in a linear manner in the low dose range 0.01-0.5Gy and rather restore the homeostasis both in vivo and in vitro by normal physiological mechanisms such as cellular and DNA repair processes, immune reactions, antioxidant defense, adaptive responses, activation of immune functions, stimulation of growth etc. In this study, we have attempted to find the critical radiation dose range and the post irradiation period during which the antioxidant defense systems in the lungs, liver and kidneys remain stimulated in these organs after whole body exposure of the animals to low-dose radiation

  16. Effect of whole-body vibration exercise in preventing falls and fractures

    DEFF Research Database (Denmark)

    Jepsen, Ditte Beck; Thomsen, Katja; Hansen, Stinus

    2017-01-01

    OBJECTIVE: To investigate the effect of whole-body vibration exercise (WBV) on fracture risk in adults ≥50 years of age. DESIGN: A systematic review and meta-analysis calculating relative risk ratios, fall rate ratio and absolute weighted mean difference using random effects models. Heterogeneity...... of retrieved publications. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Randomised controlled trials examining the effect of WBV on fracture risk in adults ≥50 years of age. The primary outcomes were fractures, fall rates and the proportion of participants who fell. Secondary outcomes were bone mineral density...... was estimated using I2statistics, and the Cochrane Collaboration's risk of bias tool and the GRADE approach were used to evaluate quality of evidence and summarise conclusions. DATA SOURCES: The databases PubMed, Embase and the Cochrane Central Register from inception to April 2016 and reference lists...

  17. Focal thyroid incidentalomas identified with whole-body FDG-PET warrant further investigation.

    LENUS (Irish Health Repository)

    Prichard, R S

    2012-02-01

    Fluorodeoxyglucose (FDG) whole body positron emission computed tomography (PET-CT) detects clinically occult malignancy. The aim of this study was to assess the prevalence and significance of focal thyroid 18F - fluorodeoxyglucose uptake. A retrospective review of all patients who had FDG PET-CT examinations, in a single tertiary referral centre was performed. PET scan findings and the final pathological diagnosis were collated. 2105 scans were reviewed. Focal uptake was identified in 35 (1.66%) patients. Final surgical histology was available on eight patients, which confirmed papillary carcinoma in four (20%) patients and lymphoma and metastatic disease in two patients respectively. This gave an overall malignancy rate in focal thyroid uptake of at least 33%. Thyroid incidentalomas occurred with a frequency of 2.13%, with an associated malignancy rate of at least 33% in focal thyroid uptake. The high malignancy rate associated with focal thyroid uptake mandates further investigation in medically fit patients.

  18. Skeletal Muscle Thermogenesis and Its Role in Whole Body Energy Metabolism

    Directory of Open Access Journals (Sweden)

    Muthu Periasamy

    2017-10-01

    Full Text Available Obesity and diabetes has become a major epidemic across the globe. Controlling obesity has been a challenge since this would require either increased physical activity or reduced caloric intake; both are difficult to enforce. There has been renewed interest in exploiting pathways such as uncoupling protein 1 (UCP1-mediated uncoupling in brown adipose tissue (BAT and white adipose tissue to increase energy expenditure to control weight gain. However, relying on UCP1-based thermogenesis alone may not be sufficient to control obesity in humans. On the other hand, skeletal muscle is the largest organ and a major contributor to basal metabolic rate and increasing energy expenditure in muscle through nonshivering thermogenic mechanisms, which can substantially affect whole body metabolism and weight gain. In this review we will describe the role of Sarcolipin-mediated uncoupling of Sarcoplasmic Reticulum Calcium ATPase (SERCA as a potential mechanism for increased energy expenditure both during cold and diet-induced thermogenesis.

  19. Tumor glucose metabolism imaged in vivo in small animals with whole-body photoacoustic computed tomography

    Science.gov (United States)

    Chatni, Muhammad Rameez; Xia, Jun; Sohn, Rebecca; Maslov, Konstantin; Guo, Zijian; Zhang, Yu; Wang, Kun; Xia, Younan; Anastasio, Mark; Arbeit, Jeffrey; Wang, Lihong V.

    2012-07-01

    With the increasing use of small animals for human disease studies, small-animal whole-body molecular imaging plays an important role in biomedical research. Currently, none of the existing imaging modalities can provide both anatomical and glucose molecular information, leading to higher costs of building dual-modality systems. Even with image co-registration, the spatial resolution of the molecular imaging modality is not improved. Utilizing a ring-shaped confocal photoacoustic computed tomography system, we demonstrate, for the first time, that both anatomy and glucose uptake can be imaged in a single modality. Anatomy was imaged with the endogenous hemoglobin contrast, and glucose metabolism was imaged with a near-infrared dye-labeled 2-deoxyglucose.

  20. Humans adapt the initial posture in learning a whole-body kicking movement.

    Science.gov (United States)

    Reifel Saltzberg, J; Hondzinski, J M; Flanders, M

    2001-06-22

    What strategies are used in learning to control new movements? The present investigation sought to understand this process by analyzing the changes in whole-body kinematics that occurred when subjects attempted to learn an unusual kicking movement. Five novices were taught a capoeira kick that involved both the upper and lower body for balance and co-ordination. Subjects performed two sets of 60 consecutive kicks, 24 h apart. Gradual changes in the body movement and the initial posture were found. Four subjects reduced the dynamic counter-twist associated with kick initiation. These subjects also adopted a more forward initial body lean. This gradual change in initial posture appeared to obviate the early counter-twist and to facilitate both the equilibrium and the goal directed components of the kick.

  1. A whole body atlas for segmentation and delineation of organs for radiation therapy planning

    International Nuclear Information System (INIS)

    Qatarneh, S.M.; Crafoord, J.; Kramer, E.L.; Maguire, G.Q.; Brahme, A.; Noz, M.E.; Hyoedynmaa, S.

    2001-01-01

    A semi-automatic procedure for delineation of organs to be used as the basis of a whole body atlas database for radiation therapy planning was developed. The Visible Human Male Computed Tomography (CT)-data set was used as a 'standard man' reference. The organ of interest was outlined manually and then transformed by a polynomial warping algorithm onto a clinical patient CT. This provided an initial contour, which was then adjusted and refined by the semi-automatic active contour model to find the final organ outline. The liver was used as a test organ for evaluating the performance of the procedure. Liver outlines obtained by the segmentation algorithm on six patients were compared to those manually drawn by a radiologist. The combination of warping and semi-automatic active contour model generally provided satisfactory segmentation results, but the procedure has to be extended to three dimensions

  2. Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms

    International Nuclear Information System (INIS)

    Dimbylow, Peter J; Hirata, Akimasa; Nagaoka, Tomoaki

    2008-01-01

    This paper provides an intercomparison of the HPA male and female models, NORMAN and NAOMI with the National Institute of Information and Communications Technology (NICT) male and female models, TARO and HANAKO. The calculations of the whole-body SAR in these four phantoms were performed at the HPA, at NICT and at the Nagoya Institute of Technology (NIT). These were for a plane wave with a vertically aligned electric field incident upon the front of the body from 30 MHz to 3 GHz for isolated conditions. As well as investigating the general differences through this frequency range, particular emphasis was placed on the assumptions of how dielectric properties are assigned to tissues (particularly skin and fat) and the consequence of using different algorithms for calculating SAR at the higher frequencies.

  3. Whole-body vibration training increases vertical jump height in a dance population.

    Science.gov (United States)

    Wyon, Matthew; Guinan, Danielle; Hawkey, Adam

    2010-03-01

    Whole-body vibration (WBV) training has gained popularity with the strength and conditioning environment. Previous research reported improvements in strength and power after WBV interventions in untrained individuals with little hypertrophical development of the muscles, suggesting that the improvements are because of neuromuscular adaptations. The present intervention study recruited moderately trained individuals that have jumping as integral to their training. Participants were randomly allocated to an intervention or control group. The intervention group was exposed to WBV at 35 Hz for 5 minutes twice a week, whereas the control group was exposed to a similar isometric contraction stress. Results indicated that after a 6-week intervention, vertical jump height increased significantly (p < 0.05) in the intervention group than in the control group. The study concluded that WBV was able to maintain vertical jump height with very little intervention time (10 minutes a week) and therefore should be considered as an intervention form for maintaining jump performance.

  4. The elevation of blood levels of zinc protoporphyrin in mice following whole body irradiation

    International Nuclear Information System (INIS)

    Walden, T.L.; Draganac, P.S.; Farkas, W.R.

    1984-01-01

    Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. We have discovered that sublethal doses of whole body irradiation with x-rays also elevates ZPP 2-3-fold over normal levels. The ZPP level does not begin to increase until days 12-14 postirradiation and peaks between days 18 and 20 before returning to normal levels between days 28 and 35. Increasing the radiation dose delays the onset of the rise in ZPP, but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms that cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation-induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system from radiation injury

  5. Elevation of blood levels of zinc protoporphyrin in mice following whole-body irradiation

    International Nuclear Information System (INIS)

    Walden, T.L. Jr.

    1983-01-01

    Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. The author has discovered that sublethal doses of whole body irradiation with X-rays also elevates ZPP two- to three-fold over normal levels. The ZPP level does not begin to increase until days 12 to 14 post-irradiation and peaks between days 18 to 20 before returning to normal levels between days 28 to 35. Increasing the radiation dose delays the onset of the rise in ZPP but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms which cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system from radiation injury

  6. Urinary excretion of phthalates and paraben after repeated whole-body topical application in humans

    DEFF Research Database (Denmark)

    Janjua, Nadeem Rezaq; Frederiksen, Hanne; Skakkebaek, Niels E

    2008-01-01

    Diethyl phthalate (DEP), dibutyl phthalate (DBP) and butyl paraben (BP) are man-made chemicals used in personal care products, such as lotions and creams. Exposure to these chemicals causes a variety of adverse reproductive outcomes in animal studies. Humans can be exposed to these chemicals...... through dermal absorption, but there are no published data on absorption, metabolism, and excretion after dermal application. This study investigates urinary concentrations of BP and metabolites of DEP and DBP after topical application. In a 2-week single-blinded study, 26 healthy Caucasian male subjects...... were given a whole body topical application of basic cream 2 mg/cm(2) (control week) and then a cream containing 2% (w/w) of DEP, DBP and BP each (treatment week) daily. Twenty-four-hour urine samples were collected. Urinary total, and unconjugated BP, monoethyl phthalate (MEP) and monobutyl phthalate...

  7. Monitoring of the general population with an installed whole body counter at West Cumberland Hospital, Whitehaven

    International Nuclear Information System (INIS)

    Boddy, K.; Francis, R.A.; Fenwick, J.D.; McKenzie, A.L.

    1989-03-01

    Body radioactivity in the general public has been measured in 395 volunteers in the Whitehaven area, using a whole-body monitor at West Cumberland Hospital. Between October 1986 and October 1987, estimates of total body radiocaesium in 240 volunteers ranged from below detection level to 1844 Bq with a mean of 415 Bq. From October 1987 until May 1988, a further 155 volunteers were monitored, and radiation levels ranged from 34 Bq to 685 Bq, with a mean of 257 Bq. In all volunteers, the ratio of body radiocaesium to body potassium, was well below unity. The average ratio of caesium-137 to caesium-134 from October 1987 to May 1988 was 3.28, corresponding to a ratio of 1.99 at the date of Chernobyl accident. This is consistent with a Chernobyl origin as the primary source for the radiocaesium. There were discernible, but not marked, trends of increasing body radiocaesium with milk and meat/fish consumption. (author)

  8. Design of POSICAM: A high resolution multislice whole body positron camera

    International Nuclear Information System (INIS)

    Mullani, N.A.; Wong, W.H.; Hartz, R.K.; Bristow, D.; Gaeta, J.M.; Yerian, K.; Adler, S.; Gould, K.L.

    1985-01-01

    A high resolution (6mm), multislice (21) whole body positron camera has been designed with innovative detector and septa arrangement for 3-D imaging and tracer quantitation. An object of interest such as the brain and the heart is optimally imaged by the 21 simultaneous image planes which have 12 mm resolution and are separated by 5.5 mm to provide adequate sampling in the axial direction. The detector geometry and the electronics are flexible enough to allow BaF 2 , BGO, GSO or time of flight BaF 2 scintillators. The mechanical gantry has been designed for clinical applications and incorporates several features for patient handling and comfort. A large patient opening of 58 cm diameter with a tilt of +-30 0 and rotation of +-20 0 permit imaging from different positions without moving the patient. Multiprocessor computing systems and user-friendly software make the POSICAM a powerful 3-D imaging device. 7 figs

  9. Alterations of blood platelet functional tests in whole-body irradiated rabbits

    International Nuclear Information System (INIS)

    Zitko, M.; Pospisil, J.; Klir, P.; Dienstbier, Z.

    1983-01-01

    With a selected spectrum of coagulation tests the functional capacity of thrombocytes was investigated in rabbits exposed to a whole-body irradiation by means of 60 Co radiation with a LD 5/30. A reduced retraction could be proved for postirradiation days 5, 8, 11, 21, 35, and 56. A reduced formation of malondialdehyde could be identified in thrombocytes on the 8th and 21st day after irradiation. No changes could be found in determining adhesiveness, platelet aggregation caused by ADP, and PF 3 A and PF 3 F tests. In the course of additional investigations (coagulation time in unprepared and siliconized glass tubes, thromboelastogram, activated partial thromboplastine time), significant changes of coagulation time could be observed in siliconized glass tubes on the 8th, 11th, 21st, and 56th postirradiation days. (author)

  10. Maximal muscular vascular conductances during whole body upright exercise in humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Jensen-Urstad, M; Van Hall, Gerrit

    2004-01-01

    (VO(2,max)) 5.1 +/- 0.1 l min(-1) participated in the study. Femoral and subclavian vein blood flows, intra-arterial blood pressure, cardiac output, as well as blood gases in the femoral and subclavian vein, right atrium and femoral artery were determined during skiing (roller skis) at approximately...... 76% of VO(2,max) and at VO(2,max) with different techniques: diagonal stride (combined arm and leg exercise), double poling (predominantly arm exercise) and leg skiing (predominantly leg exercise). During submaximal exercise cardiac output (26-27 l min(-1)), mean blood pressure (MAP) (approximately......That muscular blood flow may reach 2.5 l kg(-1) min(-1) in the quadriceps muscle has led to the suggestion that muscular vascular conductance must be restrained during whole body exercise to avoid hypotension. The main aim of this study was to determine the maximal arm and leg muscle vascular...

  11. The effect of gamma-rays on the hemoglobin of whole-body irradiated mice

    International Nuclear Information System (INIS)

    Ashry, H.A.; Selim, N.S.; El-Behay, A.Z.

    1994-01-01

    Changes in the UV-visible absorption spectrum of mouse hemoglobin as a result of whole body irradiation were studied. White albino adult mice were exposed to a Cs-137 γ-source at a dose rate of 47.5 Gy/h to different absorbed dose values ranging from 1 to 8 Gy. Blood specimens were taken 24 h after irradiation. The UV-visible absorption spectra of hemoglobin of irradiated and control mice were measured in the wavelength range from 200 to 700 nm. The obtained results showed significant changes in the bands measured at 340 nm, in the Soret band measured at 410 nm, also, the α- and β-bands measured at 537 and 572 nm showed significant decrease in intensity with the absorbed dose increase. The absorbance measured at 630 nm showed no significant changes. The radiation effect on the animal hemoglobin was discussed on the basis of the obtained results. (Author)

  12. A database of whole-body action videos for the study of action, emotion, and untrustworthiness.

    Science.gov (United States)

    Keefe, Bruce D; Villing, Matthias; Racey, Chris; Strong, Samantha L; Wincenciak, Joanna; Barraclough, Nick E

    2014-12-01

    We present a database of high-definition (HD) videos for the study of traits inferred from whole-body actions. Twenty-nine actors (19 female) were filmed performing different actions-walking, picking up a box, putting down a box, jumping, sitting down, and standing and acting-while conveying different traits, including four emotions (anger, fear, happiness, sadness), untrustworthiness, and neutral, where no specific trait was conveyed. For the actions conveying the four emotions and untrustworthiness, the actions were filmed multiple times, with the actor conveying the traits with different levels of intensity. In total, we made 2,783 action videos (in both two-dimensional and three-dimensional format), each lasting 7 s with a frame rate of 50 fps. All videos were filmed in a green-screen studio in order to isolate the action information from all contextual detail and to provide a flexible stimulus set for future use. In order to validate the traits conveyed by each action, we asked participants to rate each of the actions corresponding to the trait that the actor portrayed in the two-dimensional videos. To provide a useful database of stimuli of multiple actions conveying multiple traits, each video name contains information on the gender of the actor, the action executed, the trait conveyed, and the rating of its perceived intensity. All videos can be downloaded free at the following address: http://www-users.york.ac.uk/~neb506/databases.html. We discuss potential uses for the database in the analysis of the perception of whole-body actions.

  13. Advantage of delayed whole-body FDG-PET imaging for tumour detection

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Kazuo; Ono, Shuichi; Akaizawa, Takashi; Fukuda, Hiroshi [Dept. of Nuclear Medicine and Radiology, Tohoku Univ., Sendai (Japan); Itoh, Masatoshi; Ozaki, Kaoru; Tashiro, Manabu; Yamaguchi, Keiichiro [Cyclotron and Radioisotope Center, Tohoku Univ. (Japan); Yamada, Kenji [Sendai Kosei Hospital (Japan)

    2001-06-01

    Delayed imaging that coincides with the highest uptake of fluorine-18 fluorodeoxyglucose (FDG) by tumour may be advantageous in oncological positron emission tomography (PET), where delineation of metastasis from normal tissue background is important. In order to identify the better imaging protocol for tumour detection, whole-body FDG-PET images acquired at 1 h and 2 h after injection were evaluated in 22 subjects, with a post-injection transmission scan at 90 min for attenuation correction. After visual interpretation, tumour uptake [tumour standardised uptake ratio (SUR)], normal tissue uptake (normal SUR) and tumour to background contrast (tumour SUR/normal tissue SUR) were evaluated in the images acquired at 1 h and at 2 h. Most malignant lesions, including primary lung cancer, metastatic mediastinal lymph nodes and lymphoma lesions, showed higher FDG uptake at 2 h than at 1 h. By contrast, benign lesions, with the exception of sarcoidosis, showed lower uptake of FDG at 2 h than at 1 h. Among normal tissues, the kidney, liver, mediastinum, lung, upper abdomen and left abdomen showed significant falls in FDG uptake from 1 h to 2 h. The lower abdomen, right abdomen and muscles (shoulder and thigh) showed no significant changes. Consequently, malignant lesions of the lung, mediastinum and upper abdomen showed significant increases in tumour to background contrast from 1 to 2 h. Three lesions (two lung cancers and a malignant lymphoma) that were equivocal on 1-h images became evident on 2-h images, changing the results of interpretation. All other malignant lesions were detected on 1-h images, but were clearer, with higher contrast, on 2-h images. Lesion-based sensitivity was improved from 92% (49/53) to 98% (52/53), and patient-based sensitivity from 78% (14/18) to 94% (17/18). It is concluded that delayed whole-body FDG-PET imaging is a better and more reliable imaging protocol for tumour detection. (orig.)

  14. Estimation of normal hydration in dialysis patients using whole body and calf bioimpedance analysis.

    Science.gov (United States)

    Zhu, Fansan; Kotanko, Peter; Handelman, Garry J; Raimann, Jochen G; Liu, Li; Carter, Mary; Kuhlmann, Martin K; Seibert, Eric; Leonard, Edward F; Levin, Nathan W

    2011-07-01

    Prescription of an appropriate dialysis target weight (dry weight) requires accurate evaluation of the degree of hydration. The aim of this study was to investigate whether a state of normal hydration (DW(cBIS)) as defined by calf bioimpedance spectroscopy (cBIS) and conventional whole body bioimpedance spectroscopy (wBIS) could be characterized in hemodialysis (HD) patients and normal subjects (NS). wBIS and cBIS were performed in 62 NS (33 m/29 f) and 30 HD patients (16 m/14 f) pre- and post-dialysis treatments to measure extracellular resistance and fluid volume (ECV) by the whole body and calf bioimpedance methods. Normalized calf resistivity (ρ(N)(,5)) was defined as resistivity at 5 kHz divided by the body mass index. The ratio of wECV to total body water (wECV/TBW) was calculated. Measurements were made at baseline (BL) and at DW(cBIS) following the progressive reduction of post-HD weight over successive dialysis treatments until the curve of calf extracellular resistance is flattened (stabilization) and the ρ(N)(,5) was in the range of NS. Blood pressures were measured pre- and post-HD treatment. ρ(N)(,5) in males and females differed significantly in NS. In patients, ρ(N)(,5) notably increased with progressive decrease in body weight, and systolic blood pressure significantly decreased pre- and post-HD between BL and DW(cBIS) respectively. Although wECV/TBW decreased between BL and DW(cBIS), the percentage of change in wECV/TBW was significantly less than that in ρ(N)(,5) (-5.21 ± 3.2% versus 28 ± 27%, p hydration between BL and DW(cBIS).

  15. Whole body positron emission tomography/computed tomography staging of metastatic choroidal melanoma.

    Science.gov (United States)

    Kurli, Madhavi; Reddy, Shantan; Tena, Lawrence B; Pavlick, Anna C; Finger, Paul T

    2005-08-01

    To evaluate whole-body positron emission tomography (PET)/computed tomography in staging of patients with metastatic choroidal melanoma. Interventional non-randomized clinical study. Twenty patients were referred for whole-body 18-fluoro-2-deoxy-D-glucose (FDG) PET/computed tomography imaging because of suspected metastatic choroidal melanoma. PET/computed tomography images were studied for the presence and distribution of metastatic melanoma. Subsequent biopsies were performed to confirm the presence of metastatic disease. Twenty patients underwent PET/computed tomography. Eighteen were imaged because of abnormal clinical, hematologic, or radiographic screening studies during the course of their follow-up after plaque brachytherapy or enucleation. Two were imaged before treatment of their primary tumor. PET/computed tomography revealed or confirmed metastatic melanoma in eight (40%) of these 20 patients. The mean time from initial diagnosis to metastasis was 47 months (range 0 to 154). The most common sites for metastases were the liver (100%), bone (50%), lung (25%), lymph nodes (25%), and subcutaneous tissue (25%). Cardiac, brain, thyroid, and posterior abdominal wall lesions (12.5%) were also noted. Six patients (75%) had multiple organ involvement. No false positives were noted. PET/computed tomography imaging also detected benign lesions of the bone and lymph nodes in three patients (15%). All patients had hepatic metastases and liver enzyme assays were abnormal in only one (12.5%) of eight patients. PET/computed tomography imaging is a sensitive tool for the detection and localization of hepatic and extra-hepatic (particularly osseous) metastatic choroidal melanoma.

  16. Distinct neuromuscular phenotypes in myotonic dystrophy types 1 and 2 : a whole body highfield MRI study.

    Science.gov (United States)

    Kornblum, Cornelia; Lutterbey, Götz; Bogdanow, Manuela; Kesper, Kristina; Schild, Hans; Schröder, Rolf; Wattjes, Mike Peter

    2006-06-01

    Myotonic Dystrophy Type 1 (DM1) and 2 (DM2) present with distinct though overlapping clinical phenotypes. Comparative imaging data on skeletal muscle involvement are not at present available. We used the novel technique of whole body 3.0 Tesla (T) Magnetic Resonance Imaging (MRI) to further characterize musculoskeletal features in DM2 and compared the results with DM1.MRI findings of 15 DM1 and 14 DM2 patients were evaluated with respect to patterns of skeletal muscle affection and clinical data using the Muscular Impairment Rating Scale (MIRS) and Medical Research Council scale (MRC). All DM1 patients had pathological MRI compared with only 5 DM2 patients. In contrast to DM2, DM1 patients showed a characteristic distribution of muscle involvement with frequent and early degeneration of the medial heads of gastrocnemius muscles, and a perifemoral semilunar pattern of quadriceps muscle affection sparing the rectus femoris. The most frequently affected muscles in DM1 were the medial heads of gastrocnemius, soleus, and vastus medialis muscles. In DM2, however, the erector spinae and gluteus maximus muscles were most vulnerable to degeneration. MRI data were in line with the clinical grading in 12 DM1 and 3 DM2 patients. In 3 DM1 and 5 DM2 patients, MRI detected subclinical muscle involvement. 9 DM2 patients with mild to moderate proximal muscle weakness and/or myalgias had normal MRI. Pathological MRI changes in DM2 emerged with increasing age and were restricted to women. Whole body 3.0T MRI is a sensitive imaging technique that demonstrated a characteristic skeletal muscle affection in DM1. In contrast, MRI was no reliable indicator for skeletal muscle involvement in mildly affected DM2 patients since myalgia and mild paresis were usually not reflected by MRI signal alterations.

  17. Assessment of an infant whole-body plethysmograph using an infant lung function model.

    Science.gov (United States)

    Reinmann, B; Stocks, J; Frey, U

    2001-04-01

    In order to facilitate international multicentre studies and improve the quality control of infant pulmonary function measurements, the European Respiratory Society-American Thoracic Society Task Force for infant lung function testing has recently developed specifications for standardized infant lung function equipment and software. A mechanical infant lung model analogue has been developed to assess whether infant lung function equipment is able to meet these requirements. However, the practical testing of infant lung function equipment using such models is highly complex because of the need to use very small pressure and flow changes, and the numerous potentially confounding factors associated with both the design of the device and the testing procedure. The aim of this study was to determine whether the infant lung model is capable of assessing the overall function of an whole-body infant- plethysmograph, using the only infant plethysmograph that was commercially available at the time as an example. The mechanical characteristics of the model such as vibrations or noise did not disturb the delicate plethysmographic measurements and thereby allowed a reliable assessment of the system. A series of tests revealed that the plethysmograph was able to measure airway resistance 1-3.5 kPa.L(-1).s with an accuracy of +/-2.5% and lung volumes 75-300 mL with an accuracy of +/-2.5% under in vitro conditions. To conclude, the infant lung model is a useful means of assessing the overall in vitro performance of infant whole-body plethysmographs, but thermal, mechanical and frequency response characteristics of such a device must be taken into account when interpreting the results of such assessments.

  18. Quantitative assessment of whole-body tumor burden in adult patients with neurofibromatosis.

    Science.gov (United States)

    Plotkin, Scott R; Bredella, Miriam A; Cai, Wenli; Kassarjian, Ara; Harris, Gordon J; Esparza, Sonia; Merker, Vanessa L; Munn, Lance L; Muzikansky, Alona; Askenazi, Manor; Nguyen, Rosa; Wenzel, Ralph; Mautner, Victor F

    2012-01-01

    Patients with neurofibromatosis 1 (NF1), NF2, and schwannomatosis are at risk for multiple nerve sheath tumors and premature mortality. Traditional magnetic resonance imaging (MRI) has limited ability to assess disease burden accurately. The aim of this study was to establish an international cohort of patients with quantified whole-body internal tumor burden and to correlate tumor burden with clinical features of disease. We determined the number, volume, and distribution of internal nerve sheath tumors in patients using whole-body MRI (WBMRI) and three-dimensional computerized volumetry. We quantified the distribution of tumor volume across body regions and used unsupervised cluster analysis to group patients based on tumor distribution. We correlated the presence and volume of internal tumors with disease-related and demographic factors. WBMRI identified 1286 tumors in 145/247 patients (59%). Schwannomatosis patients had the highest prevalence of tumors (P = 0.03), but NF1 patients had the highest median tumor volume (P = 0.02). Tumor volume was unevenly distributed across body regions with overrepresentation of the head/neck and pelvis. Risk factors for internal nerve sheath tumors included decreasing numbers of café-au-lait macules in NF1 patients (P = 0.003) and history of skeletal abnormalities in NF2 patients (P = 0.09). Risk factors for higher tumor volume included female gender (P = 0.05) and increasing subcutaneous neurofibromas (P = 0.03) in NF1 patients, absence of cutaneous schwannomas in NF2 patients (P = 0.06), and increasing age in schwannomatosis patients (p = 0.10). WBMRI provides a comprehensive phenotype of neurofibromatosis patients, identifies distinct anatomic subgroups, and provides the basis for investigating molecular biomarkers that correlate with unique disease manifestations.

  19. Compact whole-body fluorescent imaging of nude mice bearing EGFP expressing tumor

    Science.gov (United States)

    Chen, Yanping; Xiong, Tao; Chu, Jun; Yu, Li; Zeng, Shaoqun; Luo, Qingming

    2005-01-01

    Issue of tumor has been a hotspot of current medicine. It is important for tumor research to detect tumors bearing in animal models easily, fast, repetitively and noninvasivly. Many researchers have paid their increasing interests on the detecting. Some contrast agents, such as green fluorescent protein (GFP) and Discosoma red fluorescent protein (Dsred) were applied to enhance image quality. Three main kinds of imaging scheme were adopted to visualize fluorescent protein expressing tumors in vivo. These schemes based on fluorescence stereo microscope, cooled charge-coupled-device (CCD) or camera as imaging set, and laser or mercury lamp as excitation light source. Fluorescence stereo microscope, laser and cooled CCD are expensive to many institutes. The authors set up an inexpensive compact whole-body fluorescent imaging tool, which consisted of a Kodak digital camera (model DC290), fluorescence filters(B and G2;HB Optical, Shenyang, Liaoning, P.R. China) and a mercury 50-W lamp power supply (U-LH50HG;Olympus Optical, Japan) as excitation light source. The EGFP was excited directly by mercury lamp with D455/70 nm band-pass filter and fluorescence was recorded by digital camera with 520nm long-pass filter. By this easy operation tool, the authors imaged, in real time, fluorescent tumors growing in live mice. The imaging system is external and noninvasive. For half a year our experiments suggested the imaging scheme was feasible. Whole-body fluorescence optical imaging for fluorescent expressing tumors in nude mouse is an ideal tool for antitumor, antimetastatic, and antiangiogenesis drug screening.

  20. Whole body electron therapy using the Philips SL75/10 linear accelerator

    International Nuclear Information System (INIS)

    Mandelzweig, Y.; Yudelev, M.; Tatcher, M.

    1980-01-01

    Electrons produced by accelerators are always accompanied by Bremsstrahlung radiation generated by electron interactions with the accelerator exit window, monitor ionization chamber, collimator, etc. The ratio of the Bremsstrahlung x-rays to electrons depends on the design of the accelerator, beam energy and adjustment, and the treatment set-up. For the electron mode of the Philips SL75/10 linac, x-rays normally constitute 1-2% of the beam at a distance of 1 meter. While this is acceptable for conventional treatments when electrons are used for whole-body irradiation, the x-ray contamination can become excessive because of the degrading effects of the large treatment distances or scattering foils required to produce large fields. A whole body electron treatment method for the SL75/10 linac, with emphasis on the means employed to minimize the x-ray dose to the patient, is described. Measurements of the properties of the electro; beams and their x-ray components were made with the aid of a thin parallel plate ionization chamber, thermoluminescent dosimeters and films in various phantoms. From analysis of the results of the measurements a practical method for treating patients was developed. The method is based on multiple adjacent beams of 4 Mev electrons applied while the patient lies on the treatment couch at a distance of 150cm from the source. The method satisfies the clinical requirements with regard to the depth and uniformity of electron dose and the level of x-ray contamination. It is not necessary to modify the linac or to use any special devices when giving the treatment. (author)

  1. Changes in Serum Zinc, Copper and Ceruloplasmin Levels of Whole Body Gamma Irradiated Rats

    International Nuclear Information System (INIS)

    Abdou, M.I.; Shaban, H.A.; El Gohary, M.I.

    2011-01-01

    Rats are whole body irradiated with different Gamma radiation doses. Zinc and Copper, two important trace elements in the biological processes and Ceruloplasmin, a protein which carries more than 95% of serum Cu and has important roles in many vital processes are followed up in the irradiated rat sera. This work aimed to determine the changes in the serum levels of the three parameters (Zinc, Copper and Ceruloplasmin) through eight weeks follow up period (1st, 2nd, 3rd, 4th, 6th, and 8th week) post whole body gamma irradiation with three sub-lethal doses (2, 3.5 and 5 Gy) of rats. All the experimental animals did not receive any medical treatment. Zinc and Copper were measured using discrete nebulization flame atomic absorption spectrometry. Ceruloplasmin was measured using a colorimetric method. The statistical analyses of the results show that the Zinc levels of the irradiated groups decreased significantly post irradiation and then were recovered at the 6th week post irradiation. The Copper levels of the irradiated groups increased significantly and then were recovered at 6th week post irradiation. The levels of Ceruloplasmin in the same groups increased significantly throughout the whole follow up period. The conclusion is that, Zinc, Copper and Ceruloplasmin levels changed significantly in the irradiated groups compared to the control group with a maximum effect noted in the groups irradiated with the higher doses and that the lower dose irradiated groups recover earlier than the higher ones. Also the correlation between Copper and Zinc is reversible at different doses and that between Copper and Ceruloplasmin is direct

  2. Whole-Body Counter(WBC and food radiocesium contamination surveys in Namie, Fukushima Prefecture.

    Directory of Open Access Journals (Sweden)

    Yoichiro Hosokawa

    Full Text Available This study examined the internal Cs exposure of residents and the Cs present in food products produced in Namie. Whole-body counter (WBC was used for the measurement of internal exposure per each whole body of examinees.The food products which appeared to be used for consumption, were brought by residents and commercially available food items were excluded. Most of them were wild plants or food items produced by residents. Four years of data from April 2012 to March 2013 (fiscal 2012 and April 2015 to March 2016 (Fiscal 2015 were analyzed and studied.The average radioactivity measured by WBC was approximately 5 Bq for Cs-134, and 20 Bq for Cs-137 and the average committed effective dose was approximately 1 μSv. The average for the residents with detectable radioactivity was 25 μSv, and the human health effects are considered to be extremely low risk. However, the radioactivity of the affected individuals showed a higher value than the theoretical attenuation rate. The majority (83.2% of individuals exhibiting radioactivity were over 50 years old. The number of food products brought in for detection decreased as the study period progressed, but the number of food products with radioactivity had increased. While the items with a higher detection rate of radioactivity included fruits such as citron and persimmon, shiitake mushrooms exhibited the highest radioactivity. Moreover, the radioactivity of seven items in these 10 items decreased from fiscal 2012 to fiscal 2015. Mushrooms had high radioactivity and were produced over a wide area.We suggest that the elderly try to enjoy life and eat wild plants in moderation while inspecting food products. Therefore, we will continue to work in raising awareness of radiation and its potential presence in food products and thus the continuing necessity of monitoring radioactivity in food in the future.

  3. Sesamol attenuates cytogenetic damages in bone marrow cells of whole body gamma irradiated mice

    International Nuclear Information System (INIS)

    Kumar, Arun; Tamizh Selvan, G.; Adhikari, Jawahar S.; Chaudhury, N.K.

    2014-01-01

    Whole body radiation exposure cause damages to all vital organs and bone marrow is the most sensitive. Pre-treatment with antioxidant as single prophylactic dose is expected to lower induction of damages in bone marrow. In the present study we have focused on sesamol, a dietary antioxidant mediated radioprotection in bone marrow cells of gamma irradiated mice and compared with melatonin. Male C57BL/6 mice were intraperitoneally administered with sesamol (10 and 20 mg/kg body) and after 30 minutes exposed to whole body gamma radiation using 60 Co Teletherapy unit. Mice were injected with 0.2 ml of a metaphase arresting agent (0.05% colchicine) intra-peritoneally 3 hours prior to sacrifice (24 hrs. post-irradiation). Bone marrow cells were flushed out from femurs of each animal and processed for chromosomal aberration assay. Another set of experiment without colchicine injection was performed to access the DNA damage in bone marrow using alkaline comet assay. At least 100 metaphases per animal were scored under light microscope to record various aberrations and total chromosomal aberrations (TCA) was calculated. Similar measurements were performed with melatonin for comparing the efficacy of sesamol. Gamma irradiation has increased the chromatid type aberrations (break formation, fragment) and chromosomal type aberrations (ring formation, acentric) in bone marrow cells. The results have shown significant (p< 0.001) increase in TCA of irradiated mice than control. While pre-treatment of sesamol and melatonin 10 mg/kg significantly (p<0.05) reduced the TCA. The extend of protection has increased at 20 mg/kg significantly (p<0.001) as evident from the reduced TCA compared to irradiated group. Interestingly, sesamol and melatonin have shown similar extent of reduction of TCA. Thus sesamol has demonstrated strong ability to protect bone marrow at low dosage. These investigations on sesamol mediated protection in bone marrow are likely to benefit development of

  4. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi (Kawasaki Medical School, Kurashiki, Okayama (Japan))

    1994-06-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of [sup 99m]Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, [gamma]-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author).

  5. Information, Precedent, and Statute

    NARCIS (Netherlands)

    O. Yalnazov (Orlin)

    2017-01-01

    textabstractI compare precedent and statute in cost-effectiveness terms. To make laws, a lawmaker needs information. Information has a cost. That cost is sensitive to the choice of law production technology. The orthodoxy is that the courts acquire information more cheaply. Litigants volunteer it in

  6. NSCLC: primary tumor size - radiation dose-related accelerated, twice daily radiotherapy by target splitting, preceded by 2 cycles of chemotherapy. First results of a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Wurstbauer, K.; Deutschmann, H.; Kopp, P.; Kranzinger, M.; Merz, F.; Nairz, O.; Sedlmayer, F. [Univ. Clinic of Radiation Oncology, Salzburger Landeskliniken und Paracelsus Medizinische Privatuniversitaet, Salzburg (Austria); Studnicka, M. [Univ. Clinic of Pneumology, Salzburger Landeskliniken und Paracelsus Medizinische Privatuniversitaet, Salzburg (Austria)

    2007-12-15

    Ensuing a phase I trial of accelerated, twice daily high dose radiotherapy showing good tolerability, a prospective study relating primary tumor size with radiation dose in non-operated patients with non-small cell lung cancer (NSCLC) was started. From 01/2004 until 12/2006 79 patients with 81 histologically/cytologically proven NSCLC tumors were treated, representing 94% of all referred non-operated NSCLC patients in stage Mo, malignant pleural effusions excluded. For the majority of patients the conformal target splitting technique has been employed. The target is split into a cranial and a caudal part; beam arrangements in the two parts are completely independent. In order to reduce internal margins slow planning CTs (4 sec./slice) were used, patients freely breathing, 7 mm margins from gross tumor volume to planning target volume. We formed 4 groups with primary tumor sizes (mean number of 3 perpendicular diameters) < 2,5; 2,5-4,5; 4,5-6,0; > 6,0 cm (11/41/22/7 patients, respectively); tumor doses of 73,8, 79,2, 84,6 and 90,0 Gy (ICRU) were applied to the primary tumors of the patients in the respective groups. Single dose 1,8 Gy; twice daily, interval 11 h; 5 days/week; duration 33 days median (range 29-42). Macroscopically involved nodes 61,2 Gy median (range 54,0-75,6 Gy), nodes electively 45,0 Gy (to volume about 6 cm cranial to apparently involved nodes). In 62 patients chemotherapy before radiotherapy was given, 2 cycles median, generally a cisplatin or carboplatin containing doublet; no concurrent chemotherapy. Median follow-up of all patients 16,7 months, of patients alive 19,3 months. Until now 10 local failures (0/11, 3/41, 5/22, 2/7 in the respective groups) and 2 regional failures occured, resulting in an actuarial local and regional tumor control of 80,1% and 96% at 2 years, respectively. Local failures relate to the primary tumor site, regional failures to the regional node sites. Overall actuarial 1-, 2-year survival rate for all patients: 76

  7. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan

    International Nuclear Information System (INIS)

    Jing, Hongli; Li, Fang; Zhuang, Hongming; Wang, Zhenghua; Tian, Jian; Xing, Xiaoping; Jin, Jin; Zhong, Dingrong; Zhang, Jingjing

    2013-01-01

    Purpose: Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Methods: Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Results: Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Conclusions: Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO

  8. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan

    Energy Technology Data Exchange (ETDEWEB)

    Jing, Hongli, E-mail: annsmile1976@sina.com [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Li, Fang, E-mail: lifang@pumch.cn [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Zhuang, Hongming, E-mail: zhuang@email.chop.edu [Department of Radiology, The Children' s Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, 34th and Civic Ctr Blvd, Philadelphia, PA 19104 (United States); Wang, Zhenghua, E-mail: ccq1214@yahoo.com.cn [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Tian, Jian, E-mail: tianjian4809@hotmail.com [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Xing, Xiaoping, E-mail: xingxp@126.com [Department of Endocrinology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Jin, Jin, E-mail: jinjin9010@126.com [Department of Orthopedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Zhong, Dingrong, E-mail: ZhongDR@pumch.cn [Department of Pathology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Zhang, Jingjing, E-mail: zhangjingjingtag@163.com [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China)

    2013-11-01

    Purpose: Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Methods: Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Results: Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Conclusions: Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO.

  9. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Zhuang, Hongming; Wang, Zhenghua; Tian, Jian; Xing, Xiaoping; Jin, Jin; Zhong, Dingrong; Zhang, Jingjing

    2013-11-01

    Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Plasma adiponectin concentration is associated with skeletal muscle insulin receptor tyrosine phosphorylation, and low plasma concentration precedes a decrease in whole-body insulin sensitivity in humans

    DEFF Research Database (Denmark)

    Stefan, Norbert; Vozarova, Barbora; Funahashi, Tohru

    2002-01-01

    concentration and skeletal muscle IR tyrosine phosphorylation and 2) the prospective effect of plasma adiponectin concentration at baseline on change in insulin sensitivity. Fasting plasma adiponectin concentration, body composition (hydrodensitometry or dual energy X-ray absorptiometry), insulin sensitivity.......02, respectively). Longitudinally, after adjustment for age, sex, and percent body fat, low plasma adiponectin concentration at baseline was associated with a decrease in insulin sensitivity (P = 0.04). In conclusion, our cross-sectional data suggest a role of physiological concentration of fasting plasma...

  11. Effect of whole-body cryotherapy on the rheological parameters of blood in older women with spondyloarthrosis.

    Science.gov (United States)

    Kulis, Aleksandra; Misiorek, Anna; Marchewka, Jakub; Głodzik, Jacek; Teległów, Aneta; Dąbrowski, Zbigniew; Marchewka, Anna

    2017-01-01

    Cryotherapy is a physiotherapy method used to treat back pain in older persons. This study aims to evaluate the changes in the rheological parameters of blood in older women with spondyloarthrosis, who underwent whole-body cryotherapy. The experimental group comprised 69 older women with lumbar spondyloarthrosis, aged between 65 and 70 years. Due to the methodology of the procedure, the experimental group was randomly divided into three groups. Each group underwent two weeks of different types of physiotherapy: only whole-body cryotherapy (22 women); only kinesitherapy (23 women); and both cryotherapy and kinesitherapy (24 women). The control group comprised 25 women who did not undergo any form of therapy. The evaluation of the rheological properties of the blood encompassed measurements of the plasma viscosity, the erythrocyte elongation and aggregation indices, and the level of fibrinogen. The conducted rheological tests revealed a significant decrease in the erythrocyte elasticity and aggregation indices only in the group of women who had undergone both whole-body cryotherapy and kinesitherapy. Applying whole-body cryotherapy to older women with spondyloarthrosis decreases the elasticity of erythrocytes and, despite favourable changes in the aggregation parameters, problems with perfusion may still appear. For this reason, the benefit of using whole-body cryotherapy in these persons is debatable.

  12. Whole-body cryotherapy (extreme cold air exposure) for preventing and treating muscle soreness after exercise in adults.

    Science.gov (United States)

    Costello, Joseph T; Baker, Philip R A; Minett, Geoffrey M; Bieuzen, Francois; Stewart, Ian B; Bleakley, Chris

    2015-09-18

    Recovery strategies are often used with the intention of preventing or minimising muscle soreness after exercise. Whole-body cryotherapy, which involves a single or repeated exposure(s) to extremely cold dry air (below -100 °C) in a specialised chamber or cabin for two to four minutes per exposure, is currently being advocated as an effective intervention to reduce muscle soreness after exercise. To assess the effects (benefits and harms) of whole-body cryotherapy (extreme cold air exposure) for preventing and treating muscle soreness after exercise in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, the British Nursing Index and the Physiotherapy Evidence Database. We also searched the reference lists of articles, trial registers and conference proceedings, handsearched journals and contacted experts.The searches were run in August 2015. We aimed to include randomised and quasi-randomised trials that compared the use of whole-body cryotherapy (WBC) versus a passive or control intervention (rest, no treatment or placebo treatment) or active interventions including cold or contrast water immersion, active recovery and infrared therapy for preventing or treating muscle soreness after exercise in adults. We also aimed to include randomised trials that compared different durations or dosages of WBC. Our prespecified primary outcomes were muscle soreness, subjective recovery (e.g. tiredness, well-being) and adverse effects. Two review authors independently screened search results, selected studies, assessed risk of bias and extracted and cross-checked data. Where appropriate, we pooled results of comparable trials. The random-effects model was used for pooling where there was substantial heterogeneity. We assessed the quality of the evidence using GRADE. Four laboratory-based randomised controlled trials were included. These reported results for 64

  13. Diagnostic whole body scan (pre-therapy scan) in differentiated thyroid cancer: A single center community hospital experience.

    Science.gov (United States)

    Santhanam, P; Driscoll, H K; Venkatraman, P

    2016-01-01

    Diagnostic whole body scan (pre-therapy scan) with either I-123 or I-131 (radioactive isotopes of iodine) is performed to assess the extent of thyroid cancer especially distant metastasis prior to administering the therapeutic dose of I-131. Our aim of the following study was to determine the utility of the diagnostic pre-therapy scan in the management of differentiated thyroid cancer. It was a case-control study carried out by retrospective chart review, of a randomly selected 100 patients with differentiated thyroid cancer who had followed in our community hospital over the course of 1 year. We collected data on multiple variables in the subjects - including age, gender, pre-operative size of the nodules, diagnosis, stage of the malignancy, size of the tumor, multifocality, lymphovascular invasion, dose of radioiodine used for remnant ablation, recurrence rates and persistence rates. Continuous variables were compared using the independent sample Mann-Whitney U-test whereas the Chi-square test was used for nominal variables. The mean dose of radioactive iodine administered was 97.56 (±27.98) in the pre-therapy scan group and it was 97.23 (±32.40) in the control group. There was no difference between the two groups (P - 0.45). There was also no difference in the recurrence rates between the groups (P = 1.0). There was a trend toward a higher degree of persistent cancer in the group that had the pre-therapy scans (P - 0.086). Pre-therapy scan may not affect the dose of radio-iodine I-131 used for remnant ablation of differentiated thyroid cancer and does not influence the recurrence rates. This was especially true with respect to I-131 remnant ablation for low risk tumors.

  14. Whole-body {sup 18}F-FDG PET/CT for M staging in the patient with newly diagnosed nasopharyngeal carcinoma: Who needs?

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Yun-yan; Li, You-cai; Wu, Hu-bing, E-mail: wuhbym@163.com; Wang, Quan-shi; Han, Yan-jiang; Zhou, Wen-lan; Li, Hong-sheng

    2017-04-15

    Objective: Although whole-body fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography (PET)/computed tomography (CT) ({sup 18}F-FDG PET/CT) is commonly used for M staging of newly diagnosed nasopharyngeal carcinoma (NPC), some patients may not benefit from this procedure. The present study investigated which patients require this modality for M staging. Methods: Whole-body {sup 18}F FDG PET/CT results and clinical data were collected for 264 patients with newly diagnosed NPC. The relationships between distant metastasis and age, gender, pathological type, lesion size, SUVmax-T, T staging, N staging, SUVmax-N and Epstein-Barr virus (EBV) quantity were retrospectively analysed to identify factors associated with increased risk. Results: Of the 264 patients, only 37 (14.0%) were diagnosed with distant metastasis. Using multiple logistic regression analysis, EBV-positivity (OR = 13.1; 95% CI:1.61,106.80), N staging (OR = 3.05; 95% CI:1.41,6.63) and T staging (OR = 2.16; 95% CI:1.10, 4.24) were significantly related to distant metastasis (all P < 0.05). EBV DNA levels ≥ 9000 copies/ml, N3 stage and T4 stage were identified as high risk factors. A low risk of distant metastasis was found in patients with 0–1 risk factors and in those with 2 specific risk factors, T3/T4 and N2/N3 staging. Patients with EBV DNA levels ≥9000 copies/ml and N3 or T4 staging and those with 3 risk factors had a medium or high risk, with a much higher incidence of distant metastasis (χ{sup 2} = 29.896, P = 0.000), and needed a whole-body {sup 18}F FDG PET/CT for M staging. Conclusions: Due to the low incidence of distant metastasis, only patients with medium or high risk need to undergo a whole-body scan.

  15. Whole-body18F-FDG PET/CT for M staging in the patient with newly diagnosed nasopharyngeal carcinoma: Who needs?

    Science.gov (United States)

    Ren, Yun-Yan; Li, You-Cai; Wu, Hu-Bing; Wang, Quan-Shi; Han, Yan-Jiang; Zhou, Wen-Lan; Li, Hong-Sheng

    2017-04-01

    Although whole-body fluorine-18 fluorodeoxyglucose ( 18 F-FDG) positron emission tomography (PET)/computed tomography (CT) ( 18 F-FDG PET/CT) is commonly used for M staging of newly diagnosed nasopharyngeal carcinoma (NPC), some patients may not benefit from this procedure. The present study investigated which patients require this modality for M staging. Whole-body 18 F FDG PET/CT results and clinical data were collected for 264 patients with newly diagnosed NPC. The relationships between distant metastasis and age, gender, pathological type, lesion size, SUVmax-T, T staging, N staging, SUVmax-N and Epstein-Barr virus (EBV) quantity were retrospectively analysed to identify factors associated with increased risk. Of the 264 patients, only 37 (14.0%) were diagnosed with distant metastasis. Using multiple logistic regression analysis, EBV-positivity (OR=13.1; 95% CI:1.61,106.80), N staging (OR=3.05; 95% CI:1.41,6.63) and T staging (OR=2.16; 95% CI:1.10, 4.24) were significantly related to distant metastasis (all P<0.05). EBV DNA levels≥9000copies/ml, N3 stage and T4 stage were identified as high risk factors. A low risk of distant metastasis was found in patients with 0-1 risk factors and in those with 2 specific risk factors, T3/T4 and N2/N3 staging. Patients with EBV DNA levels ≥9000copies/ml and N3 or T4 staging and those with 3 risk factors had a medium or high risk, with a much higher incidence of distant metastasis (χ 2 =29.896, P=0.000), and needed a whole-body 18 F FDG PET/CT for M staging. Due to the low incidence of distant metastasis, only patients with medium or high risk need to undergo a whole-body scan. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Quantitative analysis of drug effects at the whole-body level: a case study for glucose metabolism in malaria patients.

    Science.gov (United States)

    Snoep, Jacky L; Green, Kathleen; Eicher, Johann; Palm, Daniel C; Penkler, Gerald; du Toit, Francois; Walters, Nicolas; Burger, Robert; Westerhoff, Hans V; van Niekerk, David D

    2015-12-01

    We propose a hierarchical modelling approach to construct models for disease states at the whole-body level. Such models can simulate effects of drug-induced inhibition of reaction steps on the whole-body physiology. We illustrate the approach for glucose metabolism in malaria patients, by merging two detailed kinetic models for glucose metabolism in the parasite Plasmodium falciparum and the human red blood cell with a coarse-grained model for whole-body glucose metabolism. In addition we use a genome-scale metabolic model for the parasite to predict amino acid production profiles by the malaria parasite that can be used as a complex biomarker. © 2015 Authors; published by Portland Press Limited.

  17. Stochastic resonance whole-body vibration improves postural control in health care professionals: a worksite randomized controlled trial.

    Science.gov (United States)

    Elfering, Achim; Schade, Volker; Stoecklin, Lukas; Baur, Simone; Burger, Christian; Radlinger, Lorenz

    2014-05-01

    Slip, trip, and fall injuries are frequent among health care workers. Stochastic resonance whole-body vibration training was tested to improve postural control. Participants included 124 employees of a Swiss university hospital. The randomized controlled trial included an experimental group given 8 weeks of training and a control group with no intervention. In both groups, postural control was assessed as mediolateral sway on a force plate before and after the 8-week trial. Mediolateral sway was significantly decreased by stochastic resonance whole-body vibration training in the experimental group but not in the control group that received no training (p resonance whole-body vibration training is an option in the primary prevention of balance-related injury at work. Copyright 2014, SLACK Incorporated.

  18. Simplified segmented human models for whole body and localised SAR evaluation of 20 MHz to 6 GHz electromagnetic field exposures.

    Science.gov (United States)

    Wu, Tongning; Shao, Qing; Yang, Lei

    2013-03-01

    The digital human model is a key element in evaluating the electromagnetic field (EMF) exposure. This paper proposes the application of simplified segmented human models for EMF exposure compliance evaluation with the whole body and the localised limits. The method is based on the fact that most of the EMF power absorption is concentrated in several major tissues. Two kinds of human models were simply (the proposed method) and precisely segmented from two sets of whole body magnetic resonance imaging (MRI) scanned images. The whole body average-specific absorption rate (WBA-SAR) and the peak localised SAR averaging over 10 g tissues for the two kinds of models are calculated for various exposure configurations. The results confirmed the efficiency and the validity of the proposed method. The application as evaluating the MRI radiofrequency EMF exposure is also discussed in the paper.

  19. Skeletal muscle O-GlcNAc transferase is important for muscle energy homeostasis and whole-body insulin sensitivity

    DEFF Research Database (Denmark)

    Shi, Hao; Munk, Alexander; Nielsen, Thomas Svava

    2018-01-01

    of O-GlcNAc-modified proteins in obese, type 2 diabetic people compared with well-matched obese and lean controls. Muscle-specific OGT knockout mice were lean, and whole body energy expenditure and insulin sensitivity were increased in these mice, consistent with enhanced glucose uptake and elevated...... mediates transcriptional repression of Il15 by O-GlcNAcylating Enhancer of Zeste Homolog 2 (EZH2). CONCLUSIONS: Elevated muscle O-GlcNAc levels paralleled insulin resistance and type 2 diabetes in humans. Moreover, OGT-mediated signaling is necessary for proper skeletal muscle metabolism and whole-body......-GlcNAcylation, in skeletal muscle. METHODS: We assessed O-GlcNAcylation levels in skeletal muscle from obese, type 2 diabetic people, and we characterized muscle-specific OGT knockout (mKO) mice in metabolic cages and measured energy expenditure and substrate utilization pattern using indirect calorimetry. Whole body...

  20. Acute interleukin-6 administration does not impair muscle glucose uptake or whole-body glucose disposal in healthy humans

    DEFF Research Database (Denmark)

    Steensberg, Adam; Fischer, Christian P; Sacchetti, Massimo

    2003-01-01

    The cytokine interleukin (IL)-6 has recently been linked with type 2 diabetes mellitus and has been suggested to affect glucose metabolism. To determine whether acute IL-6 administration affects whole-body glucose kinetics or muscle glucose uptake, 18 healthy young men were assigned to one of three...... and LoIL-6, respectively), followed by a rapid decline (P administration, but were asymptomatic during LoIL-6 administration. In addition, only HiIL-6 elevated (P ... adrenaline (epinephrine). IL-6 infusion, irrespective of dose, did not result in any changes to endogenous glucose production, whole-body glucose disposal or leg- glucose uptake. These data demonstrate that acute IL-6 administration does not impair whole-body glucose disposal, net leg-glucose uptake...

  1. Simplified segmented human models for whole body and localised SAR evaluation of 20 MHz to 6 GHz electromagnetic field exposures

    International Nuclear Information System (INIS)

    Wu, T.; Shao, Q.; Yang, L.

    2013-01-01

    The digital human model is a key element in evaluating the electromagnetic field (EMF) exposure. This paper proposes the application of simplified segmented human models for EMF exposure compliance evaluation with the whole body and the localised limits. The method is based on the fact that most of the EMF power absorption is concentrated in several major tissues. Two kinds of human models were simply (the proposed method) and precisely segmented from two sets of whole body magnetic resonance imaging (MRI) scanned images. The whole body average-specific absorption rate (WBA-SAR) and the peak localised SAR averaging over 10 g tissues for the two kinds of models are calculated for various exposure configurations. The results confirmed the efficiency and the validity of the proposed method. The application as evaluating the MRI radiofrequency EMF exposure is also discussed in the paper. (authors)

  2. Conditions precedent and indemnities

    International Nuclear Information System (INIS)

    Nielsen, A.D.

    1999-01-01

    The use of certain conditions which allow purchase and sale agreements to be voided without any liability to either the vendor or purchaser are discussed. The drafting issues that arise when preparing these conditions are described and some common types of conditions precedent found in oil and gas purchase and sale transactions are explained. A 'conditions precedent' was defined as being something which must happen before an interest can vest or grow or before an obligation can be performed. Vendors and purchasers use conditions precedent to provide protection against having to conclude a transaction in circumstances that are not acceptable to them. The manner in which indemnity provisions in an oil and gas purchase and sale agreement work, is also explained. These usually relate to breaches of the contract by either vendors or purchasers. Indemnity clauses are used to allocate risk between the vendor and the purchaser and to set out the mechanics by which either party may make a claim against the other. Ways in which to prepare indemnity clauses are described. 2 refs

  3. Dosimetric analysis for photon and electron beams in Whole body irradiation

    International Nuclear Information System (INIS)

    Hurtado G, M.

    1998-01-01

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm 2 fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm 3 cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of 60 Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q 1 respect at the field central axis was determined and was

  4. Effects of quadriceps strength after static and dynamic whole-body vibration exercise.

    Science.gov (United States)

    Bush, Jill A; Blog, Gabriel L; Kang, Jie; Faigenbaum, Avery D; Ratamess, Nicholas A

    2015-05-01

    Numerous studies have shown performance benefits including whole-body vibration (WBV) as a training modality or an acute exercise protocol when used as a component of the resistance training program. Some studies have indicated that performing dynamic exercises as compared with static position exercises while exposed to WBV might be beneficial; however, evidence is lacking. Thus, the purpose of this study was to determine if an acute bout of dynamic versus static squats performed during WBV results in increase in quadriceps force production by means of dynamic isokinetic knee extension and flexion exercise. Nonresistance-trained healthy young men and women (N = 21) of 18-25 years participated in 4 protocols with 2-week rest in-between. Protocol 1 consisted of 5 sets of 10 dynamic squats without vibration; Protocol 2: 5 sets of 30-second static squats without vibration; Protocol 3: 5 sets of 10 dynamic squats with 30-Hz WBV for a total of 2.5 minutes; and Protocol 4: 5 sets of 30-second static squats with 30-Hz WBV for a total of 2.5 minutes. Prestrength tests (1 set of 4 repetitions at 100° · s(-1) for the knee extension exercise) was performed within 5 minutes of starting each protocol, and poststrength testing was performed within 1 minute of completing each protocol. Strength outcomes were analyzed by repeated measures analysis of variance with a significance level set at p ≤ 0.05. A significant decrease in strength was observed after dynamic and static squats without WBV (p = 0.002); an increase in strength after dynamic squats with WBV (p = 0.003); and a decrease in strength after static squats with WBV (p = 0.003). The inclusion of WBV to dynamic resistance exercise can be an added modality to increase strength. Whole-body vibration can have varied effects in altering muscle strength in untrained individuals according to the type of resistance training performed. As a dynamic squat with WBV seems to immediately potentiate neuromuscular functioning, the

  5. A gamma camera count rate saturation correction method for whole-body planar imaging

    Science.gov (United States)

    Hobbs, Robert F.; Baechler, Sébastien; Senthamizhchelvan, Srinivasan; Prideaux, Andrew R.; Esaias, Caroline E.; Reinhardt, Melvin; Frey, Eric C.; Loeb, David M.; Sgouros, George

    2010-02-01

    Whole-body (WB) planar imaging has long been one of the staple methods of dosimetry, and its quantification has been formalized by the MIRD Committee in pamphlet no 16. One of the issues not specifically addressed in the formalism occurs when the count rates reaching the detector are sufficiently high to result in camera count saturation. Camera dead-time effects have been extensively studied, but all of the developed correction methods assume static acquisitions. However, during WB planar (sweep) imaging, a variable amount of imaged activity exists in the detector's field of view as a function of time and therefore the camera saturation is time dependent. A new time-dependent algorithm was developed to correct for dead-time effects during WB planar acquisitions that accounts for relative motion between detector heads and imaged object. Static camera dead-time parameters were acquired by imaging decaying activity in a phantom and obtaining a saturation curve. Using these parameters, an iterative algorithm akin to Newton's method was developed, which takes into account the variable count rate seen by the detector as a function of time. The algorithm was tested on simulated data as well as on a whole-body scan of high activity Samarium-153 in an ellipsoid phantom. A complete set of parameters from unsaturated phantom data necessary for count rate to activity conversion was also obtained, including build-up and attenuation coefficients, in order to convert corrected count rate values to activity. The algorithm proved successful in accounting for motion- and time-dependent saturation effects in both the simulated and measured data and converged to any desired degree of precision. The clearance half-life calculated from the ellipsoid phantom data was calculated to be 45.1 h after dead-time correction and 51.4 h with no correction; the physical decay half-life of Samarium-153 is 46.3 h. Accurate WB planar dosimetry of high activities relies on successfully compensating

  6. Prediction of whole-body fat percentage and visceral adipose tissue mass from five anthropometric variables.

    Directory of Open Access Journals (Sweden)

    Michelle G Swainson

    Full Text Available The conventional measurement of obesity utilises the body mass index (BMI criterion. Although there are benefits to this method, there is concern that not all individuals at risk of obesity-associated medical conditions are being identified. Whole-body fat percentage (%FM, and specifically visceral adipose tissue (VAT mass, are correlated with and potentially implicated in disease trajectories, but are not fully accounted for through BMI evaluation. The aims of this study were (a to compare five anthropometric predictors of %FM and VAT mass, and (b to explore new cut-points for the best of these predictors to improve the characterisation of obesity.BMI, waist circumference (WC, waist-to-hip ratio (WHR, waist-to-height ratio (WHtR and waist/height0.5 (WHT.5R were measured and calculated for 81 adults (40 women, 41 men; mean (SD age: 38.4 (17.5 years; 94% Caucasian. Total body dual energy X-ray absorptiometry with Corescan (GE Lunar iDXA, Encore version 15.0 was also performed to quantify %FM and VAT mass. Linear regression analysis, stratified by sex, was applied to predict both %FM and VAT mass for each anthropometric variable. Within each sex, we used information theoretic methods (Akaike Information Criterion; AIC to compare models. For the best anthropometric predictor, we derived tentative cut-points for classifying individuals as obese (>25% FM for men or >35% FM for women, or > highest tertile for VAT mass.The best predictor of both %FM and VAT mass in men and women was WHtR. Derived cut-points for predicting whole body obesity were 0.53 in men and 0.54 in women. The cut-point for predicting visceral obesity was 0.59 in both sexes.In the absence of more objective measures of central obesity and adiposity, WHtR is a suitable proxy measure in both women and men. The proposed DXA-%FM and VAT mass cut-offs require validation in larger studies, but offer potential for improvement of obesity characterisation and the identification of individuals

  7. The comparing results of carcinoma between three-phase and delayed whole body bone scan

    International Nuclear Information System (INIS)

    Si Hongwei; Li Xianfeng

    2004-01-01

    Purpose: Three phase bone scan is an imaging technology in nuclear medicine, which composed of blood flow phase, blood pool phase and delayed phase and the last one is often performed in routine works in department of nuclear medicine. The purpose of this study is to evaluate the merit of three-phase bone scan.Methods: In this study, we chose 54 patients who were having an regional pain which caused by benign or malignant carcinoma that diagnosed by CT, X-ray, ECT, MRI or other examinations. The imaging were acquired simultaneously from both anterior and posterior views, after a bolus injection of 1110 MBq technetium-99m-labelled methylene diphosphonate (MDP), blood phase contains 20 frame sand 3 seconds per frame, blood pool phase contains 5 frames and 1 minute per frame, delayed phase was performed 2.5 hour later. According to the results of three-phase bone scan, the patients were divided into 2 groups: normal and abnormal groups. The abnormal group includes early phase positive,delay positive and all three phase positive sets. The comparing among the 3 sets were analyzed by chi-square test and other statistic means.Results: There were 54 patients who had suffered lung cancer, breast cancer and other cancer,involved in this study, 34 males and 20 females, ranged age 17 to 88 years, were normal in 15 cases,positive in 22 cases, the results in delayed phase were positive in 9 cases, blood flow and blood pool phase showed blood flow changes in 4 cases and soft tissue tumors were seen in 4 cases. Three phase bone scan was more sensitive than delayed whole body bone scan in detecting the abnormal sites (p 0.05) The sensitivity of detecting tumors in blood flow and blood pool phase,delayed phase were respectively lower than in three phase bone scan (p<0.001).Conclusion: It is more sensitivity of detecting tumor lesions in three phase bone scan than in delayed phase whole body bone scan and the changes of blood flow and soft tissue can be seen in three phase bone scan

  8. Vitamin A values of wild-caught Cuban tree frogs (Osteopilus septentrionalis) and marine toads (Rhinella marina) in whole body, liver, and serum.

    Science.gov (United States)

    Sullivan, Kathleen E; Fleming, Greg; Terrell, Scott; Smith, Dustin; Ridgley, Frank; Valdes, Eduardo V

    2014-12-01

    Recent issues surrounding captive amphibians are often nutritionally related problems, such as hypovitaminosis A. Although supplementation of frogs with vitamin A is a topic of investigation, the underlying issue is understanding vitamin A metabolism in amphibian species. To develop a range of "normal" vitamin A concentrations for captive amphibians, baseline vitamin A concentrations must be established in wild amphibian species. In this study, two species, Cuban tree frogs (Osteopilus septentrionalis; n = 59) and marine toads (Rhinella marina; n = 20) were collected from the wild as part of an invasive species control program at Zoo Miami, Miami, Florida. Serum, liver, and whole body samples were analyzed for vitamin A content. The Cuban tree frogs showed higher concentrations on average of vitamin A in serum (82.8 ppb), liver (248.3 IU/g), and whole body (5474.7 IU/kg) samples compared with marine toads (60.1 ppb; 105.3 IU/g; 940.7 IU/kg, respectively), but differences were not significant (P = 0.22). What can be considered "normal" values of vitamin A concentrations across different amphibian species requires further investigation. Although all amphibians collected in this study appeared healthy, a larger sample size of animals, with known health histories and diets, may provide stronger evidence of normal expectations.

  9. Increased FDG uptake in the wall of the right atrium in people who participated in a cancer screening program with whole-body PET

    International Nuclear Information System (INIS)

    Fujii, Hirofumi; Ide, Michiru; Yasuda, Seiei; Takahashi, Wakoh; Shohtsu, Akira; Kubo, Atsushi

    1999-01-01

    The purpose of this study was to evaluate the characteristics of patients who showed increased FDG uptake in the wall of the right atrium. We have encountered 10 patients with increased activity in the wall of the right atrium among a total of 2,367 examinees who participated in our cancer screening program with whole-body PET. The mean age of these examinees was 62.9 yr, higher than that of the total population. All suffered from cardiac disorders, especially atrial fibrillation. FDG accumulated almost exclusively in the wall of the right atrium, whereas only slight activity was seen in the wall of the left atrium. Although the average size of the right atria was significantly enlarged, left atria were more severely dilated than right ones. Therefore overload does not seem to account for the FDG accumulation in the wall of the right atrium. In conclusion, the increased activity in the wall of the right atrium was a rare finding that was made in older people who suffered from cardiac disease. Although the mechanism of induction of the high metabolic state of glucose in the wall of the right atrium remains unclear, this unusual activity would be another false positive finding in cancer screening with whole-body FDG PET. (author)

  10. Effect of abomasal glucose infusion on splanchnic and whole-body glucose metabolism in periparturient dairy cows

    DEFF Research Database (Denmark)

    Larsen, Mogens; Kristensen, Niels Bastian

    2009-01-01

    Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism.......Six periparturient Holstein cows fitted with ruminal cannulas and permanent indwelling catheters in the hepatic portal vein, hepatic vein, mesenteric vein, and an artery were used to study the effects of abomasal glucose infusion on splanchnic and whole-body glucose metabolism....

  11. Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

    Science.gov (United States)

    Spector, E.; LeBlanc, A.; Shackelford, L.

    1995-01-01

    This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between

  12. The value of whole body bone scan in the pre-operative assessment in carcinoma of the breast

    International Nuclear Information System (INIS)

    Hahn, P.; Vikterloef, K.J.; Beckman, K.W.; Rydman, H.; Blom, O.

    1979-01-01

    In 126 patients with primary breast cancer a patient moving whole-body bone scan was performed when they first presented. None of the patients in stage I had an evidence of skeletal metastases. Two patients (3%) of 62 in stage II and 4 patients (17%) in stage III had evidence of skeletal metastases. It appears that whole-body scanning is the most accurate, sensitive and convenient method of detecting osseous metastases and of staging breast cancer. This investigation should be carried out pre-operatively. Detection of early asymptomatic bony metastases will provide a better planning of treatment with rational approach. (orig.) [de

  13. Parameters of a simple whole body counter and thyroid monitor established at the Dresden Felsenkeller underground laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sahre, P. [Rossendorf Nuclear Engineering and Analytics, Inc., Dresden (Germany); Schoenmuth, T. [Rossendorf Nuclear Engineering and Analytics, Inc., Dresden (Germany)

    1997-03-01

    At the Rossendorf Nuclear Engineering and Analytics Inc. a simple whole body counter and an iodine-thyroid monitor are used for measuring the internal contamination of workers. There is no shielding chamber in both cases. By using the chamber at the Dresden Felsenkeller underground laboratory the lower limit of detection could be improved by a factor of about 3 for whole body counting and by a factor of 2,5 for thyroid monitoring (I 131, I 125). Concerning the lower limit of detection the applicability of the German standard DIN 25 482 implemented in the Gamma-Vision software packadge is discussed in the paper. (orig.)

  14. Perilipin1 deficiency in whole body or bone marrow-derived cells attenuates lesions in atherosclerosis-prone mice.

    Directory of Open Access Journals (Sweden)

    Xiaojing Zhao

    Full Text Available The objective of this study is to determine the role of perilipin 1 (Plin1 in whole body or bone marrow-derived cells on atherogenesis.Accumulated evidence have indicated the role of Plin1 in atherosclerosis, however, these findings are controversial. In this study, we showed that Plin1 was assembled and colocalized with CD68 in macrophages in atherosclerotic plaques of ApoE-/- mice. We further found 39% reduction of plaque size in the aortic roots of Plin1 and ApoE double knockout (Plin1-/-ApoE-/- females compared with ApoE-/- female littermates. In order to verify whether this reduction was macrophage-specific, the bone marrow cells from wild-type or Plin1 deficient mice (Plin1-/- were transplanted into LDL receptor deficient mice (LDLR-/-. Mice receiving Plin1-/- bone marrow cells showed also 49% reduction in aortic atherosclerotic lesions compared with LDLR-/- mice received wild-type bone marrow cells. In vitro experiments showed that Plin1-/- macrophages had decreased protein expression of CD36 translocase and an enhanced cholesterol ester hydrolysis upon aggregated-LDL loading, with unaltered expression of many other regulators of cholesterol metabolism, such as cellular lipases, and Plin2 and 3. Given the fundamental role of Plin1 in protecting LD lipids from lipase hydrolysis, it is reasonably speculated that the assembly of Plin1 in microphages might function to reduce lipolysis and hence increase lipid retention in ApoE-/- plaques, but this pro-atherosclerotic property would be abrogated on inactivation of Plin1.Plin1 deficiency in bone marrow-derived cells may be responsible for reduced atherosclerotic lesions in the mice.

  15. Effects of Eight Months of Whole-Body Vibration Training on the Muscle Mass and Functional Capacity of Elderly Women.

    Science.gov (United States)

    Santin-Medeiros, Fernanda; Rey-López, Juan P; Santos-Lozano, Alejandro; Cristi-Montero, Carlos S; Garatachea Vallejo, Nuria

    2015-07-01

    Few intervention studies have used whole-body vibration (WBV) training in the elderly, and there is inconclusive evidence about its health benefits. We examined the effect of 8 months of WBV training on muscle mass and functional capacity in elderly women. A total of 37 women (aged 82.4 ± 5.7 years) voluntarily participated in this study. Subjects were randomly assigned to a vibration group (n = 19) or a control group (n = 18). The vibration group trained on a vertical vibration platform twice a week. The control group was requested not to change their habitual lifestyle. The quadriceps femoris muscle cross-sectional area was determined by magnetic resonance imaging. All participants were evaluated by a battery of tests (Senior Fitness Test) to determine their functional capacity, as well as handgrip strength and balance/gait. General linear repeated-measure analysis of variance (group by time) was performed to examine the effect of the intervention on the outcomes variables. After 8 months, nonstatistically significant differences in the quadriceps CSA (pre-training: 8,516.16 ± 1,271.78 mm² and post-training: 8,671.63 ± 1,389.03 mm²) (p > 0.05) were found in the WBV group (Cohen's d: -0.12), whereas the CON group significantly decreased muscle mass (pre-training: 9,756.18 ± 1,420.07 mm² and post-training: 9,326.82 ± 1,577.53 mm²), with moderate effect size evident (Cohen's d: 0.29). In both groups, no changes were observed in the functional capacity, handgrip strength and balance/gait. The WBV training could prevent the loss of quadriceps CSA in elderly women.

  16. Whole body vibration exposure in heavy earth moving machinery operators of metalliferrous mines.

    Science.gov (United States)

    Vanerkar, A P; Kulkarni, N P; Zade, P D; Kamavisdar, A S

    2008-08-01

    As mining operations get mechanized, the rate of profit generation increases and so do the rate of occupational hazards. This study deals with one such hazard - occupational vibration. The present study was carried out to determine the whole body vibration (WBV) exposure of the heavy earth moving machinery (HEMM) operators in two types of metalliferous mines in India, when they were engaged in the mining activity. Cross-comparison was done of the vibration dose value (VDV) for HEMM operators as well as each type of mine. The VDV for the shovel operator in bauxite mine was observed to be 13.53 +/- 5.63 m/s(7/4) with 25% of the readings higher than the prescribed limit whereas in iron ore mine VDV for dumper operator was 10.81 +/- 3.44 m/s(7/4) with 14.62% readings on the higher side. Cross-comparison of the VDV values for bauxite and iron ore mines revealed that it was 9.57 +/- 4.93 and 8.21 +/- 5.12 m/s(7/4) with 21.28 and 14.95% of the readings on the higher side respectively. The Student's t test level was found to be insignificant for both type of mines, indicating that the WBV exposure is not dependent on the type of mine but is dependent on the working condition and type of HEMM in operation.

  17. Whole body hyperthermia by extracorporeal circulation in spontaneously breathing sarcoma patients: hemodynamics and oxygen metabolism.

    Science.gov (United States)

    Locker, Gottfried J; Fuchs, Eva-Maria; Worel, Nina; Bojic, Andja; Heinrich, Gerhard; Brodowicz, Thomas; Clodi, Martin; Funk, Georg-Christian; Knöbl, Paul; Zielinski, Christoph C; Köstler, Wolfgang J

    2011-11-01

    This phase I study was performed to evaluate the feasibility and toxicity of a new method of extracorporeal perfusion-induced whole body hyperthermia (WBHT) in patients with advanced sarcoma avoiding the need of intubation and general anesthesia. One double-lumen femoral venous access was inserted by Seldinger's technique to obtain WBHT (41.8°C for 120 minutes) via an extracorporeal circuit. No concomitant chemotherapy was applied. Up to 4 treatments of WBHT were performed under moderate sedation in 6 spontaneously breathing patients. Invasive hemodynamic monitoring was performed by use of a pulmonary artery catheter. After their first WBHT session, 2 patients were excluded from further treatment due to transient liver toxicity or catheter-related complication, so a total of 12 cycles remained for analyses. In all patients, conscious sedation resulted in sufficient spontaneous respiration without the need for mandatory ventilation. Median time to reach the target temperature was 84 minutes (range 60-142). Hemodynamic changes revealed the expected hyperdynamic state: heart rate, cardiac index, and stroke volume index significantly increased (pmean; 0.062 µg·kg¹·min⁻¹) were necessary to maintain the mean arterial blood pressure >60 mmHg. Our data demonstrate the feasibility of this method of extracorporeal WBHT without mandatory ventilation. Hemodynamic side effects in spontaneously breathing patients during perfusion-induced WBHT seem less severe than those observed in radiant heat WBHT.

  18. Stochastic resonance whole-body vibration, musculoskeletal symptoms, and body balance: a worksite training study.

    Science.gov (United States)

    Elfering, Achim; Arnold, Sibille; Schade, Volker; Burger, Christian; Radlinger, Lorenz

    2013-09-01

    Stochastic resonance whole-body vibration training (SR-WBV) was tested to reduce work-related musculoskeletal complaints. Participants were 54 white-collar employees of a Swiss organization. The controlled crossover design comprised two groups each given 4 weeks of exercise and no training during a second 4-week period. Outcome was daily musculoskeletal well-being, musculoskeletal pain, and surefootedness. In addition, participants performed a behavioral test on body balance prior to when SR-WBV started and after 4 weeks of SR-WBV. Across the 4-week training period, musculoskeletal well-being and surefootedness were significantly increased (p pain was significantly reduced only in those who reported low back pain during the last 4 weeks prior to the study (p balance was significantly increased by SR-WBV (p < 0.05). SR-WBV seems to be an efficient option in primary prevention of musculoskeletal complaints and falls at work.

  19. Whole-body muscle MRI to detect myopathies in non-extrapyramidal bent spine syndrome

    International Nuclear Information System (INIS)

    Ohana, Mickael; Durand, Marie-Christine; Marty, Catherine; Lazareth, Jean-Philippe; Maisonobe, Thierry; Mompoint, Dominique; Carlier, Robert-Yves

    2014-01-01

    Bent spine syndrome (BSS), defined as an abnormal forward flexion of the trunk resolving in supine position, is usually related to parkinsonism, but can also be encountered in myopathies. This study evaluates whole-body muscle MRI (WB-mMRI) as a tool for detecting underlying myopathy in non-extrapyramidal BSS. Forty-three patients (90 % women; 53-86 years old) with a non-extrapyramidal BSS were prospectively included. All underwent a 1.5-T WB-mMRI and a nerve conduction study. Muscle biopsy was performed if a myopathy could not be eliminated based on clinical examination and all tests. Systematic MRI interpretation focused on peripheral and axial muscle injury; spinal posture and incidental findings were also reported. WB-mMRI was completed for all patients, with 13 muscle biopsies ultimately needed and myopathy revealed as the final etiological diagnosis in five cases (12 %). All biopsy-proven myopathies were detected by the WB-mMRI. Relevant incidental MRI findings were made in seven patients. This study supports WB-mMRI as a sensitive and feasible tool for detecting myopathy in BSS patients. Associated with electroneuromyography, it can better indicate when a muscle biopsy is needed and guide it when required. Rigorous radiological interpretation is mandatory, so as not to miss incidental findings of clinical consequence. (orig.)

  20. Mechanical component design for upgrading of whole body counter ND7500

    International Nuclear Information System (INIS)

    Norizam Saad; Mohamad Annuar Assadat Husain; Ishak Mansor

    2007-01-01

    The Whole Body Counter (WBC) ND7500 is a bed type counting system that used for measuring radionuclide in the entire human body. Malaysian Nuclear Agency has this system, which savaged from Institute of Medical Research (IMR) in 1987. This system consists of a nuclear counting system and mechanical system that totally inoperable due to its counting system failures. In April 2003, both counting system and the mechanical system were tested. The mechanical component is working properly but needs some readjustment for the bed movement while for the counting system, only detectors can work but with a poor detecting capability. During IAEA expert visits on July 2003, both detectors were verified cannot be use any longer due to poor resolution and aging factor and a single (3 x 5 x 16) inches rectangular NaI(Tl) detector was then purchased in the end of 2004 to replace (3 x 5) inches cylindrical Na(Tl) detectors. The existing shielding cannot accommodate this new (3 x 5 x 16) inches dimension and the (5 x 16) inches detecting area. Therefore, shielding modification has been done based on effective detecting area and positioning test results. A new detector's entrance and detector stage were built at the bottom shielding. A new features, which is a detectors protection also been developed for detector safety. This upgrading task successfully accomplished as from experimental the design of positioning component can make system operated easily and also can give a good results to meets user's requirements. (Author)

  1. Osteonecrosis detected by whole body magnetic resonance in patients with Hodgkin Lymphoma treated by BEACOPP

    Energy Technology Data Exchange (ETDEWEB)

    Albano, Domenico; La Grutta, Ludovico; Grassedonio, Emanuele; Brancatelli, Giuseppe; Lagalla, Roberto; Midiri, Massimo; Galia, Massimo [University of Palermo, Department of Radiology, DIBIMED, Palermo (Italy); Patti, Caterina; Mule, Antonino [Azienda Ospedali Riuniti Villa Sofia-Cervello, Department of Hematology I, Palermo (Italy)

    2017-05-15

    The purpose of our retrospective review of prospectively acquired Whole Body Magnetic Resonance (WB-MRI) scans was to assess the incidence of osteonecrosis in patients who received different chemotherapies. We evaluated the WB-MRI scans performed on 42 patients with Hodgkin Lymphoma treated by three chemotherapy regimens (6ABVD, 2ABVD + 4BEACOPP, 2ABVD + 8BEACOPP), excluding patients with the main risk factors for osteonecrosis. Six out of seven patients (86 %) who received eight BEACOPP and one out of five patients (20 %) treated by four BEACOPP presented osteonecrosis, with a statistically significant difference of frequency between the two groups of patients (p < 0.05); no injury has been reported in patients treated by only ABVD. Among a total of 48 osteonecrotic lesions observed, 48 % were detected in the knee; multifocal osteonecrosis were detected in six out of seven patients (86 %). The development of osteonecrosis is strictly related to the chemotherapy protocol adopted and the number of cycles received, with a strong correlation between the dose of corticosteroids included in the BEACOPP scheme and this complication. WB-MRI can be considered as a helpful tool that allows detecting earlier osteonecrotic lesions in patients treated with corticosteroids. (orig.)

  2. Radioimmunoscintigraphy by whole body and SPECT in patients with ovarian cancer

    International Nuclear Information System (INIS)

    Piperkova, E.N.; Chakalova, G.; Christova, N.

    1994-01-01

    Several reports show that computed tomography can not always discriminate postoperative fibrosis from tumor lesions, and normal values of the serum levels of tumor marker Ca-125 do not garantee absence of primary, residual or recurrent ovarian carcinoma. Radioimmunoscintigraphy (RIS) with 131-Iodine-B72. 3 anti TAG 72, activity 92. 6 MBq (Iodomab-R3, BIOMEDICA-SORIN) was performed on twelve females with histologically confirmed ovarian carcinoma. Whole body and SPECT images were obtained 24, 48, and 72 hours after intravenous injection of monoclonal antibody (MoAb) on DIACAM gamma-camera system (Siemens). Before the treatment three patients had positive scans. After the treatment for detecting the therapeutic response or recurrence 3 true positive, 4 true negative, 1 false positive and 1 false negative scans were taken. RIS with 131-I-B 72. 3 anti TAG72 MoAb showed 86%(6/7) sensitivity and 80%(4/5) specificity. RIS can be used ovarian cancer diagnostics for primary tumor lesions detecting as well residual or recurrent disease

  3. Biomechanical Model for Computing Deformations for Whole-Body Image Registration: A Meshless Approach

    Science.gov (United States)

    Li, Mao; Miller, Karol; Joldes, Grand Roman; Kikinis, Ron; Wittek, Adam

    2016-01-01

    Patient-specific biomechanical models have been advocated as a tool for predicting deformations of soft body organs/tissue for medical image registration (aligning two sets of images) when differences between the images are large. However, complex and irregular geometry of the body organs makes generation of patient-specific biomechanical models very time consuming. Meshless discretisation has been proposed to solve this challenge. However, applications so far have been limited to 2-D models and computing single organ deformations. In this study, 3-D comprehensive patient-specific non-linear biomechanical models implemented using Meshless Total Lagrangian Explicit Dynamics (MTLED) algorithms are applied to predict a 3-D deformation field for whole-body image registration. Unlike a conventional approach which requires dividing (segmenting) the image into non-overlapping constituents representing different organs/tissues, the mechanical properties are assigned using the Fuzzy C-Means (FCM) algorithm without the image segmentation. Verification indicates that the deformations predicted using the proposed meshless approach are for practical purposes the same as those obtained using the previously validated finite element models. To quantitatively evaluate the accuracy of the predicted deformations, we determined the spatial misalignment between the registered (i.e. source images warped using the predicted deformations) and target images by computing the edge-based Hausdorff distance. The Hausdorff distance-based evaluation determines that our meshless models led to successful registration of the vast majority of the image features. PMID:26791945

  4. Whole-body vibration training as complement to programs aimed at weight loss.

    Science.gov (United States)

    Cristi-Montero, Carlos; Cuevas, María J; Collado, Pilar S

    2013-01-01

    Whole-body vibration training (WBVT) has been shown to be an extremely useful tool for increasing muscle mass, bone tissue, muscle power, flexibility, and strength, among others. However, to date, there are few studies on the effects of WBVT on energy metabolism and whether this tool could be able to enhance weight loss in addition to a nutritional plan and/or exercise. The aim of this review is to analyse the most recent studies on vibration training in order to determine whether this method constitutes a reliable complement to programs aimed at weight loss. An updated literature search was conducted using PubMed, SciELO and SPORTDiscus. In addition, a detailed search was also performed from references given in selected studies. WBVT appears to be associated with three pathways involved in weight loss: inhibition of adipogenesis and reduction of fat mass, increased energy expenditure, and increase in muscle mass. After analysing the literature, none of the results for the proposed pathways are consistent, and indeed are often contradictory. Further in-depth research is required on this subject. However, WBVT would appear to be a safe method, and may possibly yield benefits, mainly as regards muscle mass, which in turn might promote weight loss when combined with a nutritional plan and a traditional exercise program. Copyright © AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  5. Effect of whole-body gamma radiation on tissue sulfhydryl contents in experimental rats

    International Nuclear Information System (INIS)

    Sarkar, S.R.; Singh, L.R.; Uniyal, B.P.

    1985-01-01

    It has been postulated that vital constituents of cell membranes concerned with the maintenance of cellular integrity are affected by ionizing radiation. Sulfhydryl contents, which form an integral component of cell membranes play vital roles in maintaining cellular integrity. The purpose was to evaluate non-protein and protein sulfhydryl contents in tissues of irradiated rats. Adult male Sprague Dawley rats were exposed to whole-body gamma irradiation of 4 Gy and 10 Gy and non-protein and protein sulfhydryl contents of blood, heart and spleen were studied on postirradiation day 1, 3 and 6. Both groups of experimental rats exhibited unchanged blood non-protein sulfhydryl contents on first day after irradiation with significant diminution subsequently. In contrast, blood protein sulfhydryl groups of both groups of rats were increased on first day post exposure, which became normal on sixth day. Myocardial non-protein and protein sulfhydryl contents of both groups of rats remained unchanged in the initial stage of radiation exposure indicating radioresistance nature of rat heart. Both groups of rats demonstrated biphasic nature of non-protein sulfhydryl contents in spleen, asrevealed by initial increase with subsequent decrease. Protein sulfhydryl contents of rats of 4 Gy group showed significant diminution post exposure throughout, while the same of 10 Gy behaved in opposite way. (author)

  6. Whole-body photoreceptor networks are independent of 'lenses' in brittle stars.

    Science.gov (United States)

    Sumner-Rooney, Lauren; Rahman, Imran A; Sigwart, Julia D; Ullrich-Lüter, Esther

    2018-01-31

    Photoreception and vision are fundamental aspects of animal sensory biology and ecology, but important gaps remain in our understanding of these processes in many species. The colour-changing brittle star Ophiocoma wendtii is iconic in vision research, speculatively possessing a unique whole-body visual system that incorporates information from nerve bundles underlying thousands of crystalline 'microlenses'. The hypothesis that these might form a sophisticated compound eye-like system regulated by chromatophores has been extensively reiterated, with investigations into biomimetic optics and similar supposedly 'visual' structures in living and fossil taxa. However, no photoreceptors or visual behaviours have ever been identified. We present the first evidence of photoreceptor networks in three Ophiocoma species, both with and without microlenses and colour-changing behaviour. High-resolution microscopy, immunohistochemistry and synchrotron tomography demonstrate that putative photoreceptors cover the animals' oral, lateral and aboral surfaces, but are absent at the hypothesized focal points of the microlenses. The structural optics of these crystal 'lenses' are an exaptation and do not fulfil any apparent visual role. This contradicts previous studies, yet the photoreceptor network in Ophiocoma appears even more widespread than previously anticipated, both taxonomically and anatomically. © 2018 The Author(s).

  7. Whole-Body Motion Planning for Humanoid Robots by Specifying Via-Points

    Directory of Open Access Journals (Sweden)

    ChangHyun Sung

    2013-07-01

    Full Text Available We design a framework about the planning of whole body motion for humanoid robots. Motion planning with various constraints is essential to success the task. In this research, we propose a motion planning method corresponding to various conditions for achieving the task. We specify some via-points to deal with the conditions for target achievement depending on various constraints. Together with certain constraints including task accomplishment, the via-point representation plays a crucial role in the optimization process of our method. Furthermore, the via-points as the optimization parameters are related to some physical conditions. We applied this method to generate the kicking motion of a humanoid robot HOAP-3. We have confirmed that the robot was able to complete the task of kicking a ball over an obstacle into a goal in addition to changing conditions of the location of a ball. These results show that the proposed motion planning method using via-point representation can increase articulation of the motion.

  8. Eye-head coordination in the guinea pig I. Responses to passive whole-body rotations.

    Science.gov (United States)

    Shanidze, N; Kim, A H; Raphael, Y; King, W M

    2010-09-01

    Vestibular reflexes act to stabilize the head and eyes in space during locomotion. Head stability is essential for postural control, whereas retinal image stability enhances visual acuity and may be essential for an animal to distinguish self-motion from that of an object in the environment. Guinea pig eye and head movements were measured during passive whole-body rotation in order to assess the efficacy of vestibular reflexes. The vestibulo-ocular reflex (VOR) produced compensatory eye movements with a latency of approximately 7 ms that compensated for 46% of head movement in the dark and only slightly more in the light (54%). Head movements, in response to abrupt body rotations, also contributed to retinal stability (21% in the dark; 25% in the light) but exhibited significant variability. Although compensatory eye velocity produced by the VOR was well correlated with head-in-space velocity, compensatory head-on-body speed and direction were variable and poorly correlated with body speed. The compensatory head movements appeared to be determined by passive biomechanical (e.g., inertial effects, initial tonus) and active mechanisms (the vestibulo-collic reflex or VCR). Chemically induced, bilateral lesions of the peripheral vestibular system abolished both compensatory head and eye movement responses.

  9. Eye - head coordination in the guinea pig I. Responses to passive whole body rotations

    Science.gov (United States)

    Shanidze, N.; Kim, A. H.; Raphael, Y.; King, W. M.

    2010-01-01

    Vestibular reflexes act to stabilize the head and eyes in space during locomotion. Head stability is essential for postural control whereas retinal image stability enhances visual acuity and may be essential for an animal to distinguish self-motion from that of an object in the environment. Guinea pig eye and head movements were measured during passive whole body rotation in order to assess the efficacy of vestibular reflexes. The vestibulo-ocular reflex (VOR) produced compensatory eye movements with a latency of ~7 msec that compensated for 46% of head movement in the dark and only slightly more in the light (54%). Head movements, in response to abrupt body rotations, also contributed to retinal stability (21% in the dark; 25% in the light) but exhibited significant variability. Although compensatory eye velocity produced by the VOR was well correlated with head-in-space velocity, compensatory head-on-body speed and direction were variable and poorly correlated with body speed. The compensatory head movements appeared to be determined by passive biomechanical (e.g., inertial effects, initial tonus) and active mechanisms (the vestibulo-collic reflex or VCR). Chemically induced, bilateral lesions of the peripheral vestibular system abolished both compensatory head and eye movement responses. PMID:20686891

  10. Whole Body Vibration at Different Exposure Frequencies: Infrared Thermography and Physiological Effects

    Directory of Open Access Journals (Sweden)

    Anelise Sonza

    2015-01-01

    Full Text Available The aim of this study was to investigate the effects of whole body vibration (WBV on physiological parameters, cutaneous temperature, tactile sensitivity, and balance. Twenty-four healthy adults (25.3±2.6 years participated in four WBV sessions. They spent 15 minutes on a vibration platform in the vertical mode at four different frequencies (31, 35, 40, and 44 Hz with 1 mm of amplitude. All variables were measured before and after WBV exposure. Pressure sensation in five anatomical regions and both feet was determined using Von Frey monofilaments. Postural sway was measured using a force plate. Cutaneous temperature was obtained with an infrared camera. WBV influences the discharge of the skin touch-pressure receptors, decreasing sensitivity at all measured frequencies and foot regions (P≤0.05. Regarding balance, no differences were found after 20 minutes of WBV at frequencies of 31 and 35 Hz. At 40 and 44 Hz, participants showed higher anterior-posterior center of pressure (COP velocity and length. The cutaneous temperature of the lower limbs decreased during and 10 minutes after WBV. WBV decreases touch-pressure sensitivity at all measured frequencies 10 min after exposure. This may be related to the impaired balance at higher frequencies since these variables have a role in maintaining postural stability. Vasoconstriction might explain the decreased lower limb temperature.

  11. Study of food intake dynamics in rats following acute whole-body irradiation with X rays

    International Nuclear Information System (INIS)

    Smajda, B.; Ahlers, I.; Datelinka, I.

    1987-01-01

    The effects were studied of whole-body X-irradiation with sublethal (2.39 Gy) and medium lethal (5.74 Gy) doses on food intake by rats. The lower dose caused a temporary decrease in food intake, with a minimum of 63.3% of the control level on the 2nd day after irradiation. The decrease was statistically significant up to the 4th day after irradiation. No substantial changes were observed in the parameters of the circadian rhythm in food intake with the maximum on the 3rd day after irradiation, with only 8% of the initial value. The food intake was reduced until the 9th day after irradiation. The daily thythm of food intake was strongly disturbed during the first three days after irradiation, then restoring gradually and on the 9th day showing the original phasing and shape. The results obtained were in agreement with the assumed neural regulation mechanism of food intake and its circadian rhythm in the rat. (author). 5 figs., 12 refs

  12. Whole body [{sup 11}C]-dihydrotetrabenazine imaging of baboons: biodistribution and human radiation dosimetry estimates

    Energy Technology Data Exchange (ETDEWEB)

    Murthy, Rajan [Columbia University College of Physicians and Surgeons, Department of Psychiatry, New York, NY (United States); New York State Psychiatric Institute, Department of Neuroscience, Division of Brain Imaging, New York, NY (United States); Harris, Paul; Leibel, Rudolph [Columbia University College of Physicians and Surgeons, Department of Medicine, New York, NY (United States); Simpson, Norman; Parsey, Ramin [Columbia University College of Physicians and Surgeons, Department of Psychiatry, New York, NY (United States); Van Heertum, Ronald [Columbia University College of Physicians and Surgeons, Department of Radiology, New York, NY (United States); New York State Psychiatric Institute, Department of Neuroscience, Division of Brain Imaging, New York, NY (United States); Mann, J.J. [Columbia University College of Physicians and Surgeons, Department of Psychiatry, New York, NY (United States); Columbia University College of Physicians and Surgeons, Department of Radiology, New York, NY (United States); New York State Psychiatric Institute, Department of Neuroscience, Division of Brain Imaging, New York, NY (United States)

    2008-04-15

    Vesicular monoamine transporter type 2 abundance quantified using the radiotracer [{sup 11}C]-dihydrotetrabenazine (DTBZ) has been used to study diagnosis and pathogenesis of dementia and psychiatric disorders in humans. In addition, it may be a surrogate marker for insulin-producing pancreatic beta cell mass, useful for longitudinal measurements using positron emission tomography to track progression of autoimmune diabetes. To support the feasibility of long-term repeated administrations, we estimate the biodistribution and dosimetry of [{sup 11}C]-DTBZ in humans. Five baboon studies were acquired using a Siemens ECAT camera. After transmission scanning, 165-210 MBq of [{sup 11}C]-DTBZ were injected, and dynamic whole body emission scans were conducted. Time-activity data were used to obtain residence times and estimate absorbed radiation dose according to the MIRD model. Most of the injected tracer localized to the liver and the lungs, followed by the intestines, brain, and kidneys. The highest estimated absorbed radiation dose was in the stomach wall. The largest radiation dose from [{sup 11}C]-DTBZ is to the stomach wall. This dose estimate, as well as the radiation dose to other radiosensitive organs, must be considered in evaluating the risks of multiple administrations. (orig.)

  13. Antigenic profile, isolation and characterization of whole body extract of Paramphistomum gracile.

    Science.gov (United States)

    Anuracpreeda, P; Chawengkirttikul, R; Sobhon, P

    2016-07-01

    An antigenic component of adult Paramphistomum gracile was characterized by means of indirect enzyme-linked immunosorbent assay (indirect ELISA), sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and immunoblotting using sera from cattle naturally infected with P. gracile, Eurytrema pancreaticum, Fasciola gigantica, Moniezia benedeni, strongylids, Trichuris sp. and Strongyloides sp. The whole body (WB) extracts of P. gracile were fractionated by gel filtration chromatography in a Sephadex G-200 column. It was found that the WB extract fractions, F1-F3 were highly antigenic, F5 was moderately antigenic and F4 was poorly antigenic. For SDS-PAGE and immunoblotting, the antigenic molecules of WB extract and all five fractions were mostly at molecular weights (MW) ranging from 12 to 150 kDa. One antigenic protein of 16 kDa detected in WB extract and F1-F3 was found to give a consistent reaction with sera from infected cattle. The antigenicity of the purified 16 kDa protein was confirmed by immunoblotting and indirect ELISA using a pool of sera and individual serum samples from infected cattle (at 1 : 78 125 dilution) and hyperimmunized rabbit (at 1 : 390 625 dilution). This finding suggests that the 16 kDa protein may be a potential antigen for the immunodiagnosis of cattle paramphistomosis caused by P. gracile. © 2016 John Wiley & Sons Ltd.

  14. Acute effect of whole-body vibration on high velocity squat and jump performance

    Directory of Open Access Journals (Sweden)

    Carlos Ugrinowitsch

    2010-09-01

    Full Text Available The objective of this study was to assess the acute effect of whole-body vibration (WBV on power production of the lower limbs during squat exercise and on vertical jump height. The performance of 30 strength-trained subjects was assessed during high velocity squat exercise (HVS and countermovement vertical jump (CMJ before and after being submitted to four different vibration protocols in a counterbalanced random manner. The HVS and CMJ assessments were performed 3 min before and 6, 9 and 12 min after the WBV interventions, and 6 min before and 9 and 15 min after the interventions, respectively. The different WBV protocols did not change relative peak or average power production during HVS and CMJ. However, time exerted a main effect, with a decrease in CMJ height at 3 min (-2% and 15 min (-3.1% after treatment. These results suggest that the WBV protocols employed in this study do not induce acute improvement in performance. However, this finding does not rule out the application of WBV as a useful strategy for training or warm-up routines.

  15. Assessing internal exposures and the efficacy of countermeasures from whole body measurements

    International Nuclear Information System (INIS)

    Likhtarev, I.; Kovgan, L.; Gluvchinsky, R.; Perevoznikov, O.; Morrey, M.; Prosser, S.L.; Jacob, P.; Prohl, G.; Kenigsberg, Y.; Skryabin, A.M.; Colgen, P.A.

    1996-01-01

    Traditional procedures for modelling the ingestion dose pathway combine environmental transfer models with human metabolic models in order to assess the doses received. In general, these models have been developed for specific ecological and socio-economic circumstances, rather than for globally-averaged conditions. Experiences which occurred following the Chernobyl accident have demonstrated that in the event of a large scale radiation accident it will be virtually impossible to monitor adequately all the radiologically significant components of human diet which may have become contaminated with radionuclides. This paper describes an internal dosimetry model based on the most widely available measurements following an accident: radiocesium measurements in soil and milk, and whole body measurements in humans. One application of the model to estimate ingestion doses received by inhabitants of the northern region of the Rovno Region in Ukraine is also described. In addition, this model enables the effectiveness of food Countermeasures to be estimated. This study formed part of Joint Study Programme 5 (JSP5) on pathway analysis and dose distributions and was jointly funded by the European Commission (EC) and Commonwealth of Independent States (CIS)

  16. Whole-body magnetic resonance angiography with blood-pool agents

    International Nuclear Information System (INIS)

    Kramer, H.; Morana, G.

    2007-01-01

    Although often asymptomatic, peripheral arterial disease (PAD) is associated with significant morbidity in a large proportion of patients. Atherosclerosis is the underlying pathology in many instances, involving the whole arterial tree. Whole-body magnetic resonance angiography (MRA) permits rapid, non-invasive and accurate evaluation of the entire vascular system and can be used for both diagnostic purposes and monitoring of vascular involvement in diseases such as diabetes, Marfan's syndrome and Takayasu arteritis. MRA has been used successfully in the identification of high-grade stenosis in PAD, abnormalities of the ileocaval veins and carotid plaque imaging. Carotid disease is significantly correlated with severe coronary artery disease and renal artery atherosclerosis. Symptomatic lesions in one vascular bed are often related to additional asymptomatic atherosclerotic lesions in other vascular regions. MRA may be advantageous over computed tomographic angiography because it can be performed with contrast media virtually devoid of serious toxicity and without utilization of ionizing radiation. Display of the entire arterial vasculature can be achieved in < 90 s, with excellent sensitivity and specificity. Recent technological advances, such as parallel imaging and the implementation of dedicated matrix coils, have further increased image quality, and in combination with the blood-pool contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), extended imaging time, higher spatial resolution and larger anatomical coverage can be achieved. (orig.)

  17. Whole-body magnetic resonance angiography with blood-pool agents

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, H. [Inst. for Clinical Radiology, Univ. Hospital Munich, Munich (Germany); Morana, G. [Radiological Dept., Hospital Ca' Foncello, Treviso (Italy)

    2007-03-15

    Although often asymptomatic, peripheral arterial disease (PAD) is associated with significant morbidity in a large proportion of patients. Atherosclerosis is the underlying pathology in many instances, involving the whole arterial tree. Whole-body magnetic resonance angiography (MRA) permits rapid, non-invasive and accurate evaluation of the entire vascular system and can be used for both diagnostic purposes and monitoring of vascular involvement in diseases such as diabetes, Marfan's syndrome and Takayasu arteritis. MRA has been used successfully in the identification of high-grade stenosis in PAD, abnormalities of the ileocaval veins and carotid plaque imaging. Carotid disease is significantly correlated with severe coronary artery disease and renal artery atherosclerosis. Symptomatic lesions in one vascular bed are often related to additional asymptomatic atherosclerotic lesions in other vascular regions. MRA may be advantageous over computed tomographic angiography because it can be performed with contrast media virtually devoid of serious toxicity and without utilization of ionizing radiation. Display of the entire arterial vasculature can be achieved in < 90 s, with excellent sensitivity and specificity. Recent technological advances, such as parallel imaging and the implementation of dedicated matrix coils, have further increased image quality, and in combination with the blood-pool contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), extended imaging time, higher spatial resolution and larger anatomical coverage can be achieved. (orig.)

  18. EFFECTS OF WHOLE BODY VIBRATION ON STRENGTH AND JUMPING PERFORMANCE IN VOLLEYBALL AND BEACH VOLLEYBALL PLAYERS

    Science.gov (United States)

    Zmijewski, P.; Jimenez-Olmedo, J.M.; Jové-Tossi, M.A.; Martínez-Carbonell, A.; Suárez-Llorca, C.; Andreu-Cabrera, E.

    2014-01-01

    The primary aim of this study was to examine the effects of 6-week strength training with whole body vibration (WBV) on leg strength and jumping performance in volleyball and beach volleyball players. Twenty-three sub-elite male volleyball (VB; n=12) and beach volleyball players (BVB; n=11) aged 21.2±3.0 years were divided into two groups and subjected to 6 weeks of strength training (three one-hour sessions per week): (I) 12 players (6 VB and 6 BVB players) underwent training with WBV (30-40 Hz, 1.7-2.5 mm, 3.0-5.7 g), and (II) 11 players (6 VB and 5 BVB players) underwent traditional strength training. Squat jump (SJ) and countermovement squat jump (CMJ) measurements by the Ergo Tester contact platform and maximum leg press test (1RM) were conducted. Three-factor (2 time x 2 WBV use x 2 discipline) analysis of variance for SJ, CMJ and 1RM revealed a significant time main effect (pvolleyball and beach volleyball players increases leg strength more and leads to greater improvement in jump performance than traditional strength training, but greater improvements can be expected in beach volleyball players than in volleyball players. PMID:25187676

  19. Procedure guideline for iodine-131 whole-body scintigraphy for differentiated thyroid cancer (version 3)

    International Nuclear Information System (INIS)

    Dietlein, M.; Schicha, H.; Eschner, W.; Deutsche Gesellschaft fuer Medizinische Physik; Koeln Univ.; Gruenwald, F.; Frankfurt Univ.; Lassmann, M.; Deutsche Gesellschaft fuer Medizinische Physik; Wuerzburg Univ.; Leisner, B.; Allgemeines Krankenhaus St. Georg, Hamburg; Luster, M.; Reiners, C.; Wuerzburg Univ.; Schober, O.; Muenster Univ.

    2007-01-01

    Version 3 of the procedure guideline for 131 I whole-body scintigraphy (WBS) is the counterpart to the procedure guideline for radioiodine therapy (version 3) and specify the interdisciplinary guideline for thyroid cancer of the Deutsche Krebsgesellschaft concerning the nuclear medicine part. 131 I WBS 3-6 months after 131 I ablation remains a standard procedure in an endemic area for thyroid nodules and the high frequency of subtotal surgical procedures. Follow-up without 131 I WBS is only justified if the following preconditions are fulfilled: low-risk group pT1-2, pN0 M0 with histopathologically confirmed pN0, 131 I uptake 131 I WBS during ablation without any suspicious lesion, stimulated thyroglobulin (Tg)-level 3-6 months after ablation 131 I WBS 3-6 months after ablation and stimulated Tg is of 131 I WBS. If patients from the high-risk group show normal 131 I WBS and stimulated Tg-level of 131 I WBS will be not necessary. The recommended intervals for stimulated Tg-testing are adapted to the prior intervals for 131 I WBS-testing in the high-risk group. Increased anti-thyroglobulin-antibodies or incomplete recovery-testing make an individual strategy of follow-up care necessary, which include 131 I WBS. (orig.)

  20. Initial Clinical Experience in Multiple Myeloma Staging by Means of Whole-Body Resonance Techniques

    International Nuclear Information System (INIS)

    Gallego, J. I.; Concepcion, L.; Alonso, S.; Sanchez, B.; Manzi, F.

    2003-01-01

    To develop a magnetic resonance (MR) exploratory technique equivalent to serial bone X-ray, and to compare their precision in the staging of multiple myeloma (MM) patients. Multiple acquisition T1-weights TSE and STIR sequences in the coronal plane were performed. Ten healthy volunteers and 11 multiple myeloma diagnosed patients were included. The visualization of bony structures was particularly noted,with special attention given to those which would normally be included in a serial bone X-ray. In the case of the patients, a comparison was made between diagnostic capacities of the MR sequences. MR highlighters significantly more (p<0.05) bony elements than did the serial bone X-ray. This was greatly due to a sequential displacement of the scanner bed, allowing for field-of-views which were minimally from head to third proximal of the leg. Magnetic resonance detected a significantly higher number (p<0.05) of lesions. It was, in turn, capable of revealing greater lesion extensions, even to the point of implying staging classification changes in 18% of the patients. The utilization of whole-body MR techniques in multiple myeloma patients is feasible and clinically beneficial. MR is both more sensitive and more specific than serial bone X-ray for evaluation of bony lesions in MM. It is currently serving as a valid alternative in a growing numbers of patients. (Author) 10 refs