WorldWideScience

Sample records for sirolimus eluting stents

  1. Zotarolimus-eluting vs. sirolimus-eluting coronary stents in patients with and without acute coronary syndromes

    DEFF Research Database (Denmark)

    Thim, Troels; Maeng, Michael; Kaltoft, Anne Kjer

    2012-01-01

    To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial.......To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial....

  2. Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Kelbæk, Henning; Kløvgaard, Lene

    2010-01-01

    To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries.......To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries....

  3. Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V)

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Jensen, Lisette Okkels; Thayssen, Per

    2013-01-01

    Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer......-coated sirolimus-eluting stent in a population-based setting....

  4. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial

    NARCIS (Netherlands)

    de Winter, Robbert J.; Katagiri, Yuki; Asano, Taku; Milewski, Krzysztof P.; Lurz, Philipp; Buszman, Pawel; Jessurun, Gillian A. J.; Koch, Karel T.; Troquay, Roland P. T.; Hamer, Bas J. B.; Ophuis, Ton Oude; Wöhrle, Jochen; Wyderka, Rafał; Cayla, Guillaume; Hofma, Sjoerd H.; Levesque, Sébastien; Żurakowski, Aleksander; Fischer, Dieter; Kośmider, Maciej; Goube, Pascal; Arkenbout, E. Karin; Noutsias, Michel; Ferrari, Markus W.; Onuma, Yoshinobu; Wijns, William; Serruys, Patrick W.

    2018-01-01

    Background MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical

  5. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  6. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial.

    Science.gov (United States)

    de Winter, Robbert J; Katagiri, Yuki; Asano, Taku; Milewski, Krzysztof P; Lurz, Philipp; Buszman, Pawel; Jessurun, Gillian A J; Koch, Karel T; Troquay, Roland P T; Hamer, Bas J B; Ophuis, Ton Oude; Wöhrle, Jochen; Wyderka, Rafał; Cayla, Guillaume; Hofma, Sjoerd H; Levesque, Sébastien; Żurakowski, Aleksander; Fischer, Dieter; Kośmider, Maciej; Goube, Pascal; Arkenbout, E Karin; Noutsias, Michel; Ferrari, Markus W; Onuma, Yoshinobu; Wijns, William; Serruys, Patrick W

    2018-02-03

    MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population. We did a randomised, single-blind, multicentre, phase 3 study (DESSOLVE III) at 20 hospitals in Germany, France, Netherlands, and Poland. Eligible participants were any patients aged at least 18 years who underwent percutaneous coronary intervention in a lesion and had a reference vessel diameter of 2·50-3·75 mm. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting bioresorbable polymer stent (MiStent) or an everolimus-eluting durable polymer stent (Xience). Randomisation was done by local investigators via web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint (DOCE)-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between the groups at 12 months after the procedure assessed by intention-to-treat. A margin of 4·0% was defined for non-inferiority of the MiStent group compared with the Xience group. All participants were included in the safety analyses. This trial is registered with ClinicalTrials.gov, number NCT02385279. Between March 20, and Dec 3, 2015, we randomly assigned 1398 patients with 2030 lesions; 703 patients with 1037 lesions were assigned to MiStent, of whom 697 received the index procedure, and 695 patients with 993 lesions were asssigned to Xience, of whom 690 received the index procedure. At 12 months, the primary endpoint had occurred in 40 patients (5·8%) in the sirolimus-eluting stent group and in 45

  7. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  8. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  9. Safety and Efficacy of Everolimus- Versus Sirolimus-Eluting Stents

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Christiansen, Evald Høj

    2016-01-01

    BACKGROUND: Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown. OBJECTIVES: This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical...... rate was lower with EES (HR: 0.71, 95% CI: 0.55 to 0.90; p = 0.006; p interaction = 0.12). Definite stent thrombosis was lower with EES (0.4%) than with SES (2.0%; HR: 0.18, 95% CI: 0.07 to 0.46), with a lower risk of very late definite stent thrombosis in the EES group (0.2% vs. 1.4%, respectively; HR...... in Non-selected Patients With Coronary Heart Disease [SORT OUT IV]; NCT00552877)....

  10. Bioabsorbable polymer-coated sirolimus-eluting stent implantation preserves coronary vasomotion: A DESSOLVE II trial sub-study.

    Science.gov (United States)

    Rusinaru, Dan; Vrolix, Mathias; Verheye, Stefan; Chowdhary, Saqib; Schoors, Danny; Di Mario, Carlo; Desmet, Walter; Donohoe, Dennis J; Ormiston, John A; Knape, Charlene; Bezerra, Hiram; Lansky, Alexandra; Wijns, William

    2015-12-01

    We studied coronary vasomotion in patients treated with the Mistent(®) absorbable polymer sirolimus-eluting stent (APSES) and in patients implanted with the Endeavor(®) zotarolimus-eluting stent (ZES). First generation (1st-gen) drug-eluting stents (DES) induce persistent vasomotor dysfunction in the treated coronary artery. It is unknown whether and to what extent the implantation of an absorbable polymer DES impairs coronary vasomotion. This sub-study of the DESSOLVE II trial included 19 APSES Mistent(®) and 10 ZES Endeavor(®) patients. Incremental atrial pacing and quantitative coronary angiography were used to assess vasomotion proximal and distal to the stent and in a reference segment at 9 months after implantation. Percent changes in vessel diameter with pacing versus baseline were calculated and compared. Vasomotor response of the APSES group was also compared with changes observed in a historical group of 17 patients implanted with a 1st-gen sirolimus-eluting stent (SES). Normal vasomotion (vasodilatation) was preserved and of comparable magnitude in the APSES and in the ZES group both proximally (P = 0.34) and distally (P = 0.38) to the stent. This finding was not observed in the 1st-gen SES group showing marked pacing-induced vasoconstriction at both stent edges (P absorbable polymer sirolimus-eluting stent is associated with preserved coronary vasomotion, comparable to that observed after implantation of the Endeavor(®) ZES, and distinct from 1st-gen SES which induce coronary vasomotor dysfunction. © 2015 Wiley Periodicals, Inc.

  11. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  12. Type D personality predicts death or myocardial infarction after bare metal stent or sirolimus-eluting stent implantation

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Lemos, Pedro A; van Vooren, Priya R

    2004-01-01

    We investigated the effect of Type D personality on the occurrence of adverse events at nine months in patients with ischemic heart disease (IHD) after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SESs) or bare stents. Type D patients experience increased negative...

  13. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...... of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients....

  14. Advantages of novel BioMimeTM Sirolimus Eluting Coronary Stent system. Moving towards biomimicry.

    Science.gov (United States)

    Upendra, K; Sanjeev, B

    2012-02-01

    Since the first reported use of percutaneous transluminal coronary angioplasty (PTCA), advancements in interventional cardiology arena have been fast paced. Within the last ten years, these developments have been exponential. Developers & clinicians are fast adapting from the learning curve awarded by the time course of DES evolution. In that light BioMimeTM Sirolimus Eluting Coronary Stent comes as a fresh thought in taking stents towards a biomimicry concept. The stent is built on an ultra-low strut thickness (65 µm) cobalt chromium stent platform, using an intelligent hybrid of close and open cells allowing for morphology mediated expansion, employs a well known anti-proliferative - Sirolimus that elutes from a biodegradable co-polymer formulation in 30 days and ensures high coating integrity and low coating thickness of 2 µm. The resultant stent demonstrates almost 100% endothelialization at 30 days in preclinical model and zero percent MACE >18 months in the primary efficacy and safety clinical study.

  15. Randomized clinical comparison of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent with the sirolimus-eluting Orsiro stent in patients treated with percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jakobsen, Lars; Christiansen, Evald H; Maeng, Michael

    2018-01-01

    Background: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have...... designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. Methods: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro...... stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion...

  16. 2-year clinical outcomes after implantation of sirolimus-eluting, paclitaxel-eluting, and bare-metal coronary stents: results from the WDHR (Western Denmark Heart Registry)

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Jensen, Lisette Okkels; Maeng, Michael

    2009-01-01

    OBJECTIVES: This registry study assessed the safety and efficacy of the 2 types of drug-eluting stents (DES), sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), compared with bare-metal stents (BMS). BACKGROUND: Drug-eluting stents may increase the risk of stent thrombosis (ST...... databases. We used Cox regression analysis to control for confounding. RESULTS: The 2-year incidence of definite ST was 0.64% in BMS patients, 0.79% in DES patients (adjusted relative risk [RR]: 1.09; 95% confidence interval [CI]: 0.72 to 1.65), 0.50% in SES patients (adjusted RR: 0.63, 95% CI: 0.35 to 1...

  17. Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study)

    DEFF Research Database (Denmark)

    Maeng, Michael; Tilsted, Hans Henrik; Jensen, Lisette Okkels

    2014-01-01

    received two different types of drug-eluting stents. METHODS: We undertook this multicentre, open-label, randomised superiority trial at five percutaneous coronary intervention centres in Denmark. We randomly allocated 2332 eligible adult patients (≥18 years of age) with an indication for drug......-eluting stent implantation to the zotarolimus-eluting Endeavor Sprint stent (Medtronic, Santa Rosa, CA, USA) or the sirolimus-eluting Cypher Select Plus stent (Cordis, Johnson & Johnson, Warren, NJ, USA). Randomisation of participants was achieved by computer-generated block randomisation and a telephone...

  18. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  19. XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent

    NARCIS (Netherlands)

    Beijk, Marcel A. M.; Piek, Jon J.

    2007-01-01

    Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the

  20. Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

    Science.gov (United States)

    Lansky, Alexandra J; Kastrati, Adnan; Edelman, Elazer R; Parise, Helen; Ng, Vivian G; Ormiston, John; Wijns, William; Byrne, Robert A

    2016-02-15

    We compared the outcomes of a novel, thin-strut, cobalt-chromium, absorbable, polymer sirolimus-eluting stent (APSES; MiStent) to the durable polymer cobalt-chromium everolimus-eluting stent (EES; Xience). A propensity-matched analysis was performed comparing data from the DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesions in the Native Coronary Arteries (DESSOLVE) I and II studies, evaluating the APSES to the EES arm of the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents-4 study. Target lesion failure (TLF) and its components were evaluated at 12 months and annually to 3 years; 805 patients (APSES = 153; EES = 652) were included with propensity matching in 204 patients (APSES = 102; EES = 102). APSES compared with EES had lower TLF at 1 year (3.0% vs 8.0%, p = 0.12) driven by a difference in target lesion revascularization (TLR; 1% vs 6%, p = 0.05), with no difference in target vessel myocardial infarction (p = 0.56) or stent thrombosis (p = 0.31). At 3 years, TLF (5.0% vs 12.5%, p = 0.07) and TLR (2.0% vs 8.4%, p = 0.04) remained lower with APSES. By landmark analysis, there was no significant difference in TLF between 1 and 3 years (p = 0.36). In conclusion, in a propensity-matched analysis, the APSES demonstrated reduced clinically indicated TLR rates at 1 and 3 years compared with the durable polymer EES, with minimal accrual of events between 1 and 3 years. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Randomized comparison of a sirolimus-eluting Orsiro stent with a biolimus-eluting Nobori stent in patients treated with percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Maeng, Michael

    2015-01-01

    BACKGROUND: Third-generation coronary drug-eluting stents (DES) with biodegradable polymers have been designed to improve safety and efficacy. We designed a large scale registry-based randomized clinical trial to compare 2 third-generation DES: a thin strut, cobalt-chromium DES with silicon carbide......-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the stainless steel biodegradable polymer biolimus-eluting Nobori stents (N-BES, Nobori; Terumo, Tokyo, Japan) in an all-comer patient population. DESIGN: The multicenter SORT OUT VII trial (NCT01879358...... will be used. An event rate of 6.5% is assumed in each stent group. With a sample size of 1,157 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the O-SES compared with the N...

  2. Rationale and Design of a Randomized Clinical Comparison of Everolimus-Eluting (Xience V/Promus) and Sirolimus-Eluting (Cypher Select+) Coronary Stents in Unselected Patients with Coronary Heart Disease

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Tilsted, Hans Henrik

    2010-01-01

    with Clinical Outcome (SORT OUT) IV trial was designed as a prospective, multi-center, open-label, all-comer, two-arm, randomized, non-inferiority study comparing the everolimus-eluting stent with the sirolimus-eluting stent in the treatment of atherosclerotic coronary artery lesions. Based on a non...

  3. Nine-month Angiographic and Two-year Clinical Follow-up of Novel Biodegradable-polymer Arsenic Trioxide-eluting Stent Versus Durable-polymer Sirolimus-eluting Stent For Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Li Shen

    2015-01-01

    Full Text Available Background: Despite great reduction of in-stent restenosis, first-generation drug-eluting stents (DESs have increased the risk of late stent thrombosis due to delayed endothelialization. Arsenic trioxide, a natural substance that could inhibit cell proliferation and induce cell apoptosis, seems to be a promising surrogate of sirolimus to improve DES performance. This randomized controlled trial was to evaluate the efficacy and safety of a novel arsenic trioxide-eluting stent (AES, compared with traditional sirolimus-eluting stent (SES. Methods: Patients with symptoms of angina pectoris were enrolled and randomized to AES or SES group. The primary endpoint was target vessel failure (TVF, and the second endpoint includes rates of all-cause death, cardiac death or myocardial infarction, target lesion revascularization (TLR by telephone visit and late luminal loss (LLL at 9-month by angiographic follow-up. Results: From July 2007 to 2009, 212 patients were enrolled and randomized 1:1 to receive either AES or SES. At 2 years of follow-up, TVF rate was similar between AES and SES group (6.67% vs. 5.83%, P = 0.980. Frequency of all-cause death was significantly lower in AES group (0 vs. 4.85%, P = 0.028. There was no significant difference between AES and SES in frequency of TLR and in-stent restenosis, but greater in-stent LLL was observed for AES group (0.29 ± 0.52 mm vs. 0.10 ± 0.25 mm, P = 0.008. Conclusions: After 2 years of follow-up, AES demonstrated comparable efficacy and safety to SES for the treatment of de novo coronary artery lesions.

  4. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    BACKGROUND: In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery...... disease who were receiving routine clinical care with no direct follow-up. METHODS: We did a single-blind, all-comer superiority trial in adult patients with chronic stable coronary artery disease or acute coronary syndromes, and at least one target lesion. Patients were treated at one of five...... Danish administrative and health-care registries. The primary endpoint was a composite of major adverse cardiac events within 9 months: cardiac death, myocardial infarction, and target vessel revascularisation. Intention-to-treat analyses were done at 9-month and 18-month follow-up. This trial...

  5. Long-term Outcomes of Paclitaxel-Eluting Versus Sirolimus-Eluting Stent for Percutaneous Coronary Intervention: A Meta-Analysis

    International Nuclear Information System (INIS)

    Kong, J.; Liu, P.; Fan, X.; Wen, J.; Zhang, J.; Zhen, Y.; Li, J.; Cui, Y.; Zheng, X.; Ye, Z.

    2017-01-01

    The relative long-term efficacy and safety of sirolimus-eluting stents (SES) compared with paclitaxel-eluting stents (PES) in multiple comparative studies remains controversial. This report evaluates 29 randomized trials with 18,379 patients in whom long-term (more than 1 year) outcomes were evaluated. The primary outcomes were target lesion revascularization (TLR) and the secondary end points were death, cardiac death, myocardial infarction (MI), major adverse cardiac events (MACEs), target vessel revascularization (TVR)and stent thrombosis (ST). In comparison with PES, SES significantly reduced the long-term risk of TLR (RR=0.68; 95% CI=0.57 to 0.80, p<0.001), TVR (RR=0.69; 95% CI= 0.60 to 0.79, p<0.001) and MACE (RR=0.82; 95% CI= 0.77 to 0.88, p<0.001), while there were no significant difference with respect to death, cardiac death, MI and ST between the two groups. SES performance was significantly better for reducing the former three outcomes and comparable for the majority of the secondary end points when compared against PES. (author)

  6. Paclitaxel-eluting versus sirolimus-eluting stents in diabetes mellitus: a report from the National Heart, Lung, and Blood Institute Dynamic Registry.

    Science.gov (United States)

    Wolf, William M; Vlachos, Helen A; Marroquin, Oscar C; Lee, Joon S; Smith, Conrad; Anderson, William D; Schindler, John T; Holper, Elizabeth M; Abbott, J Dawn; Williams, David O; Laskey, Warren K; Kip, Kevin E; Kelsey, Sheryl F; Mulukutla, Suresh R

    2010-02-01

    Diabetes is a powerful predictor of adverse events in patients undergoing percutaneous coronary intervention. Drug-eluting stents reduce restenosis rates compared with bare metal stents; however, controversy remains regarding which drug-eluting stents provides greater benefit in patients with diabetes. Accordingly, we compared the safety and efficacy of sirolimus-eluting stents (SES) with paclitaxel-eluting stents (PES) among diabetic patients in a contemporary registry. Using the National Heart, Lung, and Blood Institute Dynamic Registry, we evaluated 2-year outcomes of diabetic patients undergoing percutaneous coronary interventions with SES (n=677) and PES (n=328). Clinical and demographic characteristics, including age, body mass index, insulin use, left ventricular function, and aspirin/clopidogrel use postprocedure, did not differ significantly between the groups except that PES-treated patients had a greater frequency of hypertension and hyperlipidemia. At the 2-year follow-up, no significant differences were observed between PES and SES with regard to safety or efficacy end points. PES- and SES-treated patients had similar rates of death (10.7% versus 8.2%, P=0.20), death and myocardial infarction (14.9% versus 13.6%, P=0.55), repeat revascularization (14.8% versus 17.8%, P=0.36), and stent thrombosis (1.3% versus 1.3%, P=0.95). After adjustment, no significant differences between the 2 stent types in any outcome were observed. PES and SES are equally efficacious and have similar safety profiles in diabetic patients undergoing percutaneous coronary interventions in clinical practice.

  7. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.

    Science.gov (United States)

    Serruys, Patrick W; Farooq, Vasim; Kalesan, Bindu; de Vries, Ton; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Eberli, Franz; Wijns, William; Morice, Marie Claude; Di Mario, Carlo; Corti, Roberto; Antoni, Diethmar; Sohn, Hae Y; Eerdmans, Pedro; Rademaker-Havinga, Tessa; van Es, Gerrit-Anne; Meier, Bernhard; Jüni, Peter; Windecker, Stephan

    2013-08-01

    This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority 1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study

    Directory of Open Access Journals (Sweden)

    Teeuwen Koen

    2012-12-01

    Full Text Available Abstract Background Percutaneous recanalization of total coronary occlusion (TCO was historically hampered by high rates of restenosis and reocclusions. The PRISON II trial demonstrated a significant restenosis reduction in patients treated with sirolimus-eluting stents compared with bare metal stents for TCO. Similar reductions in restenosis were observed with the second-generation zotarolimus-eluting stent and everolimus-eluting stent. Despite favorable anti-restenotic efficacy, safety concerns evolved after identifying an increased rate of very late stent thrombosis (VLST with drug-eluting stents (DES for the treatment of TCO. Late malapposition caused by hypersensitivity reactions and chronic inflammation was suggested as a probable cause of these VLST. New DES with bioresorbable polymer coatings were developed to address these safety concerns. No randomized trials have evaluated the efficacy and safety of the new-generation DES with bioresorbable polymers in patients treated for TCO. Methods/Design The prospective, randomized, single-blinded, multicenter, non-inferiority PRISON IV trial was designed to evaluate the safety, efficacy, and angiographic outcome of hybrid sirolimus-eluting stents with bioresorbable polymers (Orsiro; Biotronik, Berlin, Germany compared with everolimus-eluting stents with durable polymers (Xience Prime/Xpedition; Abbott Vascular, Santa Clara, CA, USA in patients with successfully recanalized TCOs. In total, 330 patients have been randomly allocated to each treatment arm. Patients are eligible with estimated duration of TCO ≥4 weeks with evidence of ischemia in the supply area of the TCO. The primary endpoint is in-segment late luminal loss at 9-month follow-up angiography. Secondary angiographic endpoints include in-stent late luminal loss, minimal luminal diameter, percentage of diameter stenosis, in-stent and in-segment binary restenosis and reocclusions at 9-month follow-up. Additionally, optical coherence

  9. Stent Thrombosis With Drug-Eluting Stents and Bioresorbable Scaffolds: Evidence From a Network Meta-Analysis of 147 Trials.

    Science.gov (United States)

    Kang, Si-Hyuck; Chae, In-Ho; Park, Jin-Joo; Lee, Hak Seung; Kang, Do-Yoon; Hwang, Seung-Sik; Youn, Tae-Jin; Kim, Hyo-Soo

    2016-06-27

    This study sought to perform a systematic review and network meta-analysis to compare the relative safety and efficacy of contemporary DES and BVS. To improve outcomes of patients undergoing percutaneous coronary revascularization, there have been advances in the design of drug-eluting stents (DES), including the development of drug-eluting bioresorbable vascular scaffolds (BVS). Prospective, randomized, controlled trials comparing bare-metal stents (BMS), paclitaxel-eluting stents (PES), sirolimus-eluting stents (SES), Endeavor zotarolimus-eluting stents (E-ZES), cobalt-chromium (CoCr) everolimus-eluting stents (EES), platinum-chromium (PtCr)-EES, biodegradable polymer (BP)-EES, Resolute zotarolimus-eluting stents (R-ZES), BP biolimus-eluting stents (BP-BES), hybrid sirolimus-eluting stents (H [Orsiro]-SES), polymer-free sirolimus- and probucol-eluting stents, or BVS were searched in online databases. The primary endpoint was definite or probable stent thrombosis at 1 year. A total of 147 trials including 126,526 patients were analyzed in this study. All contemporary DES were superior to BMS and PES in terms of definite or probable stent thrombosis at 1 year. CoCr-EES, PtCr-EES, and H-SES were associated with significantly lower risk than BVS. CoCr-EES and H-SES were superior to SES and BP-BES. The risk of myocardial infarction was significantly lower with H-SES than with BVS. There were no significant differences regarding all-cause or cardiac mortality. Contemporary devices including BVS showed comparably low risks of repeat revascularization. Contemporary DES, including biocompatible DP-DES, BP-DES, and polymer-free DES, showed a low risk of definite or probable stent thrombosis at 1 year. BVS had an increased risk of device thrombosis compared with CoCr-EES, PtCr-EES, and H-SES. Data from extended follow-up are warranted to confirm the long-term safety of contemporary coronary devices. Copyright © 2016 American College of Cardiology Foundation. Published by

  10. Drug-eluting stents and bare metal stents in patients with NSTE-ACS

    DEFF Research Database (Denmark)

    Pedersen, Sune Haahr; Pfisterer, Matthias; Kaiser, Christoph

    2014-01-01

    the randomised BASKET-PROVE trial (sirolimus-eluting stent vs. everolimus-eluting stent vs. bare metal stent in large-vessel stenting). The primary endpoint was the combined two-year rate of cardiovascular death or non-fatal myocardial infarction (MI). Secondary endpoints were each component of the primary...... implantation in large vessels was associated with a reduction in both TVR and the combined endpoint consisting of cardiovascular death/MI. Thus, DES use improves both efficacy and safety. These findings support the use of DES in NSTE-ACS patients....

  11. A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India.

    Science.gov (United States)

    Chandra, Praveen; Kumar, Tarun

    2014-01-01

    A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  12. Development of a sirolimus-eluting poly (L-lactide)/poly(4-hydroxybutyrate) absorbable stent for peripheral vascular intervention.

    Science.gov (United States)

    Grabow, Niels; Bünger, Carsten M; Kischkel, Sabine; Timmermann, J Hinrich; Reske, Thomas; Martin, David P; Williams, Simon F; Schareck, Wolfgang; Sternberg, Katrin; Schmitz, Klaus-Peter

    2013-10-01

    Fully absorbable drug-eluting stent platforms are currently entering the clinical arena for the interventional treatment of coronary artery disease. This new technology also holds potential for application in peripheral vascular settings. Our study reports on the development of a sirolimus- (SIR) eluting absorbable polymer stent made from a blend of poly(l-lactide) and poly(4-hydroxybutyrate) (PLLA/P4HB) for peripheral vascular intervention. Stent prototypes were laser-cut from PLLA/P4HB tubes (I.D.=2.2 mm, t=250 µm), spray-coated with different PLLA/P4HB/SIR solutions, and bench-tested to determine expansion properties, fatigue, trackability and in vitro drug release kinetics. The stent prototypes were expanded with a 5.0 × 20 mm balloon catheter, and exhibited a recoil of 3.6% upon balloon deflation. Stent collapse pressure of 0.4 bar (300 mm Hg) was measured under external pressure load. Sustained scaffolding properties were observed in vitro over 14 weeks of radial fatigue loading (50 ± 25 mm Hg at 1.2 Hz). Trackability was demonstrated in bench tests with an 8 French contralateral introducer sheath. SIR release kinetics were adjusted over a broad range by varying the PLLA/P4HB ratio of the coating matrix. The newly developed absorbable SIR-eluting PLLA/P4HB stent successfully fulfilled the requirements for peripheral vascular intervention under in vitro conditions.

  13. Favorable Outcomes after Implantation of Biodegradable Polymer Coated Sirolimus-Eluting Stents in Diabetic Population: Results from INDOLIMUS-G Diabetic Registry

    Directory of Open Access Journals (Sweden)

    Anurag Polavarapu

    2015-01-01

    Full Text Available Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE, which is a composite of cardiac death, target lesion revascularization (TLR, target vessel revascularization (TVR, myocardial infarction (MI, and stent thrombosis (ST. The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion. There were 256 (68.8% male patients. Hypertension and totally occluded lesions were found in 202 (54.3% and 45 (10.3% patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%, 6 (1.6%, and 8 (2.2%, respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population.

  14. Serial assessment by optical coherence tomography of early and late vascular responses after implantation of an absorbable-coating Sirolimus-Eluting stent (from the first-in-human DESSOLVE I trial).

    Science.gov (United States)

    Attizzani, Guilherme F; Bezerra, Hiram G; Ormiston, John; Wang, Wei; Donohoe, Dennis; Wijns, William; Costa, Marco A

    2013-11-15

    The initial enthusiasm caused by the potent antirestenotic effect of early generation drug-eluting stents was recently plagued by concerns regarding their safety profile. Investigators worldwide were stimulated, therefore, to seek for improvement in drug-eluting stent technology, such as eliminating their permanent polymer blamed for vascular inflammation and delayed healing. Optical coherence tomography (OCT) assessments of stent-vessel interactions are used as a surrogate for vessel healing after DES implantation. Herewith, we report serial OCT assessments of vascular reactions to the implantation of a novel absorbable polymer sirolimus-eluting stent (MiStent). In total, 30 patients were included. At 4-, 6-, and 8-month follow-up, different groups of 10 patients underwent OCT imaging, whereas all the patients had OCT assessments scheduled at 18-month follow-up. A total of 13,569 stent struts were analyzed. Low rates of uncovered (14.34 ± 15.35%, 6.62 ± 10.93%, 3.51 ± 2.87%, and 0.84 ± 1.15%, respectively, p stent struts coupled with thin and increasingly homogenous neointimal proliferation were demonstrated. Neointimal area increased from 4- to 8-month follow-up (0.46 ± 0.29 and 1.12 ± 0.73 mm(2), respectively, p stent struts (8.8%, 3.1%, 0.3%, and 0%, respectively, p absorbable polymer sirolimus-eluting stent-vessel interactions up to 18-month follow-up. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial.

    Science.gov (United States)

    von Birgelen, Clemens; Asano, Taku; Amoroso, Giovanni; Aminian, Adel; Brugaletta, Salvatore; Vrolix, Mathias; Hernandez-Antolín, Rosana; van de Harst, Pim; Iñiguez, Andres; Janssens, Luc; Smits, Pieter C; Wykrzykowska, Joanna J; Ribeiro, Vasco Gama; Pereira, Hélder; da Silva, Pedro Canas; Piek, Jan J; Onuma, Yoshinobu; Serruys, Patrick W; Sabaté, Manel

    2018-04-20

    A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.

  16. Drug-eluting stents studies in mice: Do we need atherosclerosis to study restenosis?

    NARCIS (Netherlands)

    Pires, N.M.M.; Jukema, J.W.; Daemen, M.J.A.P.; Quax, P.H.A.

    2006-01-01

    In 2001, the first human study with drug-eluting stents (DES) was published showing a nearly complete abolition of restenosis by using a sirolimus-eluting stent. This success was very encouraging to test new compounds in combination with the DES platform. Nevertheless, several other anti-restenotic

  17. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction.

    Science.gov (United States)

    Pilgrim, Thomas; Piccolo, Raffaele; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Khattab, Ahmed A; Taniwaki, Masanori; Rigamonti, Fabio; Nietlispach, Fabian; Blöchlinger, Stefan; Wenaweser, Peter; Jüni, Peter; Windecker, Stephan

    2016-12-10

    Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.

  18. Stent implantation into the tracheo-bronchial system in rabbits: histopathologic sequelae in bare metal vs. drug-eluting stents.

    Science.gov (United States)

    Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver

    2015-12-01

    Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.

  19. Long-Term Safety of Drug-Eluting and Bare-Metal Stents

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Benedetto, Umberto; Biondi-Zoccai, Giuseppe

    2015-01-01

    BACKGROUND: Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety....... RESULTS: Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial...... infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target...

  20. Type D personality predicts chronic anxiety following percutaneous coronary intervention in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Spindler, Helle; Pedersen, Susanne S.; Serruys, Patrick W.

    2007-01-01

      Background: Anxiety is an often overlooked risk factor in coronary artery disease (CAD). Hence, little is known about predictors of unremitting chronic anxiety in CAD patients. This study examined whether the distressed personality (Type D) predicts chronic anxiety post percutaneous coronary...... months post-PCI. Results: Of 167 patients anxious at 6 months, 108 (65%) were still anxious 12 months post-PCI. Significant univariable predictors of chronic anxiety were Type D personality (OR:3.17: 95% CI:1.64-6.14) and sirolimus-eluting stents (OR:0.51; 95% CI:0.27-0.98), with sirolimus-eluting stents...... showing a protective effect. In multivariable analyses, Type D personality (OR:3.31; 95% CI:1.59-6.87) and sirolimus-eluting stents (OR:0.44; 95% CI:0.21-0.92) remained significant independent predictors of chronic anxiety adjusting for depressive symptoms at 6 months, and demographic and clinical risk...

  1. The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry.

    Science.gov (United States)

    Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M

    2012-01-01

    This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Comparison of Outcomes in Patients With Versus Without Diabetes Mellitus After Revascularization With Everolimus- and Sirolimus-Eluting Stents (from the SORT OUT IV Trial)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Junker, Anders

    2012-01-01

    Diabetes is associated with increased risk of major adverse cardiac events (MACEs) after percutaneous coronary intervention. The purpose of this substudy of the SORT OUT IV trial was to compare clinical outcomes in patients with and without diabetes mellitus treated with everolimus-eluting stents...... (EESs) or sirolimus-eluting stents (SESs). In total 2,774 patients (390 with diabetes, 14.1%) were randomized to stent implantation with EESs (n = 1,390, diabetes in 14.0%) or SESs (n = 1,384, diabetes in 14.2%). Randomization was stratified by presence/absence of diabetes. The primary end point...... was MACEs, a composite of cardiac death, myocardial infarction, definite stent thrombosis, or target vessel revascularization within 18 months. MACEs were higher in diabetic than in nondiabetic patients (13.1% vs 6.4%, hazard ratio [HR] 2.08, 95% confidence interval [CI] 1.51 to 2.86). In diabetic patients...

  3. Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating

    Directory of Open Access Journals (Sweden)

    Saito N

    2016-03-01

    Full Text Available Noboru Saito, Yuhei Mori, Sayaka Uchiyama Terumo Corporation R&D Center, Inokuchi, Nakai-machi, Ashigarakami-gun, Kanagawa, Japan Abstract: The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC, which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion direction of the drug and the biological responses of the artery to drug-eluting stent (DES by comparing the AGC-sirolimus stent and the conventional full-surface coating (CFC sirolimus stent. The study aimed to verify whether the AGC approach was appropriate for the development of a safer DES, minimizing the risks of stent thrombosis due to delayed endothelialization by the drug and distal embolization due to cracking of the coating layer on the hinge parts of the DES on stent expansion. In the in vitro local drug diffusion study, we used rhodamine B as a model drug, and rhodamine B released from the AGC stent diffused predominantly into the abluminal side of the alginate artery model. Conversely, rhodamine B released from the CFC stent quickly spread to the luminal side of the artery model, where endothelial cell regeneration is required. In the biological responses study, the luminal surface of the iliac artery implanted with the AGC-sirolimus stent in a rabbit iliac artery for 2 weeks was completely covered with endothelial-like cells. On the other hand, the luminal surface of the iliac artery implanted with the CFC-sirolimus stent for 2 weeks only showed partial coverage with endothelial-like cells. While thrombosis was observed in two of the three CFC-sirolimus stents, it was observed in only one of the three AGC-sirolimus stents. Taken together, these findings indicate that the designed nonuniform coating (AGC is an appropriate approach to ensure a safer DES. However, the number of studies is limited and a larger study should be conducted to reach a statistically

  4. Gender difference on five-year outcomes of EXCEL biodegradable polymer-coated sirolimus-eluting stents implantation: results from the CREATE study.

    Science.gov (United States)

    Zhang, Lei; Qiao, Bing; Han, Ya-Ling; Li, Yi; Xu, Kai; Zhang, Quan-Yu; Yang, Li-Xia; Liu, Hui-Liang; Xu, Bo; Gao, Run-Lin

    2013-03-01

    The gender difference on long-term outcome in unselected patients after percutaneous coronary intervention (PCI) has not yet been fully investigated. This study aimed to evaluate the gender difference on five-year outcomes following EXCEL biodegradable polymer-coated sirolimus-eluting stenting in patients with coronary disease. A total of 2077 "all comers", consisting of 1528 (73.6%) men and 549 (26.4%) women, who were exclusively treated with EXCEL coronary stents were enrolled in the prospective CREATE study at 59 centers from four countries. After propensity score matching, the baseline characteristics of the two groups were well matched. Recommended antiplatelet regimen was clopidogrel and aspirin for six months followed by chronic aspirin therapy. The primary outcome that was the rate of major adverse cardiac events (MACE), defined as a composite of cardiac mortality, non-fatal myocardial infarction (MI) and target lesion revascularization (TLR), and stent thrombosis (ST) at five years were compared between the two gender groups. In the two groups, women had higher proportions of clinical risk factors, such as being elderly, diabetes mellitus, hypertension and hyperlipidemia, compared to men. Besides, the mean target vessel number per patient was higher and the mean reference vessel diameter smaller for women. Men had higher risks of cardiac death (3.7% vs. 1.6%, P = 0.021) and MACE (8.4% vs. 4.7%, P = 0.004) at five years compared with women. However, the cumulative hazards of non-fatal MI and TLR were similar between men and women. The incidence of Academic Research Consortium (ARC) definite or probable stent thrombosis was similar between the two groups (1.3% vs. 1.0%, P = 0.639). Prolonged clopidogrel therapy (>6 months) did not reduce the cumulative hazards of ST from six months to five years in both men (χ(2) = 0.098, log rank P = 0.754) and women (χ(2) = 2.043, log rank P = 0.153) patients. Women had a lower MACE and cardiac death rate than men after

  5. Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated With Percutaneous Coronary Intervention: The Scandinavian Organization for Randomized Trials With Clinical Outcome IV (SORT OUT IV)

    DEFF Research Database (Denmark)

    Okkels Jensen, Lisette; Thayssen, Per; Hansen, Henrik Steen

    2012-01-01

    was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularization) parameters. The noninferiority criterion was a risk difference of 0.015. Intention-to-treat analyses were done at 9- and 18-month follow-ups. A total of 1390 patients were.......71-1.23). At the 9-month follow-up, the rate of definite stent thrombosis was higher in the sirolimus-eluting group (2 patients [0.1%] versus 9 patients [0.7%]; hazard ratio, 0.22; 95% confidence interval, 0.05-1.02). At the 18-month follow-up, this difference was sustained (3 patients [0.2%] versus 12 patients [0...

  6. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).

    Science.gov (United States)

    Ormiston, John; Webster, Mark; Stewart, James; Vrolix, Mathias; Whitbourn, Robert; Donohoe, Dennis; Knape, Charlene; Lansky, Alexandra; Attizzani, Guilherme F; Fitzgerald, Peter; Kandzari, David E; Wijns, William

    2013-10-01

    This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer-coated, sirolimus-eluting stent. Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and optical coherence tomography at 4, 6, or 8 months, and all patients were seen or contacted at 18 months of follow-up. The median (range) in-stent late lumen loss (LLL) was 0.03 mm (-0.22 to 0.21 mm), 0.10 mm (-0.03 to 1.2 mm), and 0.08 mm (-0.01 to 0.28 mm), at 4, 6, and 8 months, respectively. At 18 months, the median in-stent LLL was 0.08 mm (-0.30 to 0.46 mm). On optical coherence tomography, the proportion of uncovered stent struts decreased from a median of 7.3% (range 0.4% to 46.3%) at 4 months to 0% (range: 0% to 3.4%) at 18 months. The percentage of neointimal volume obstruction by intravascular ultrasound increased from a median of 5.3% to 9.1% between 4 and 6 months and remained nearly unchanged thereafter through 18 months of follow-up. The only recorded major adverse cardiac event was a myocardial infarction. At 18 months of follow-up, this absorbable polymer-coated, cobalt chromium sirolimus-eluting stent was associated with a low and stable in-stent LLL, complete strut coverage, and no stent thrombosis. (First-In-Human Trial of the MiStent Drug-Eluting Stent [DES] in Coronary Artery Disease [DESSOLVE-I]; NCT01247428). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Safety and efficacy of everolimus-eluting stents compared with first-generation drug-eluting stents in patients undergoing primary percutaneous coronary intervention

    Energy Technology Data Exchange (ETDEWEB)

    Escárcega, Ricardo O.; Baker, Nevin C.; Magalhaes, Marco A.; Lipinski, Michael J.; Minha, Sa’ar; Torguson, Rebecca; Satler, Lowell F.; Pichard, Augusto D.; Suddath, William O.; Waksman, Ron, E-mail: ron.waksman@medstar.net

    2014-09-15

    Objective: To assess the safety and efficacy everolimus-eluting stents (EES) compared with first-generation drug-eluting stents (DES) in patients with acute myocardial infarction (MI) undergoing primary percutaneous coronary intervention (PCI). Background: EES have been associated with improved clinical outcomes compared to paclitaxel-eluting stents (PES) and with similar outcomes compared to sirolimus-eluting stents (SES). Methods: A total of 520 patients who presented with ST-elevation myocardial infarction (STEMI) from 2003 to 2013, who underwent primary PCI with DES, were retrospectively analyzed. Of these, 247 received SES, 136 PES, and 137 EES. Patients were followed up to 2 years for major adverse cardiac events (MACE). Univariate and multivariate models detected correlates to outcome. Results: EES implantation, compared with PES and SES, resulted in comparable rates of MACE (8.8% vs. 16.2%, p = 0.06 and 8.8% vs. 12.6%, respectively, p = 0.26), stent thrombosis, MI, and target lesion revascularization. Patients who received EES had lower rates of all-cause mortality (3.7% vs. 12.6% vs. 9.4%, p = 0.03) at 1-year follow up. However, in the univariate and multivariate analyses, stent type was not independently associated with the primary outcome or with all-cause mortality. Diabetes mellitus and number of stents implanted were independently associated with the primary outcome. Conclusion: While EES seem to be associated with better outcome when compared to PES, the main correlates of STEMI patients are the presence of diabetes and number of stents implanted, and not the type of stent used for intervention.

  8. [Drug-eluting stent thrombosis and its pharmacological prevention].

    Science.gov (United States)

    Pershukov, I V; Batyraliev, T A

    2007-01-01

    The problem of drug eluting stents (DES) safety has been actively discussed throughout 2006 because of increase of frequency of development of late stent thromboses which were noted during almost 2 years after stenting. In December 2006 US Food and Drug Administration (FDA) advisory panel acknowledged increase of development of late stent thrombosis. At the same time FDA accepted new definition of stent-thrombosis suggested by the Academic Research Consortium. According to this definition thrombosis can be definite, probable and possible. Any unexplained death before end of follow-up in a trial should be considered thrombosis related. Recalculation of thrombosis rate using this definition caused pronounced increase of this parameter in previously conducted trials. Thrombosis rate rose from 0,6 to 3,3% for bare metal stents, from 0,8 to 3,6% for sirolimus eluting stents and from 1,3 to 3,5% for paclitaxel eluting stents. Professional cardiological and angiographical societies (ACC, AHA, SCAI) responding to FDA advisory panel published their proofs and vision of the problem of stent thrombosis. In February 2007 ACC, AHA, SCAI, American College of Surgeons and Association of Dentists published scientific bulletin in which described preventive measures aimed at lowering of risk of thrombosis development. This document contains strict recommendation to continue double antithrombotic therapy with aspirin and clopidogrel for 12 months after implantation of DES or abandonment of the use of this type of stents when long term double antithrombotic therapy is not possible.

  9. Incidence of adverse cardiac events 5 years after polymer-free sirolimus eluting stent implantation: Results from the prospective Bad Berka Yukon Choice™ registry.

    Science.gov (United States)

    Ohlow, Marc-Alexander; von Korn, Hubertus; Gunkel, Oliver; Farah, Ahmed; Fuhrmann, Joerg T; Lauer, Bernward

    2014-12-01

    Drug-eluting stents (DES) constitute a major achievement in preventing re-stenosis, concerns remain regarding the increased inflammatory responses associated with the polymers used. This analysis focuses on outcomes in patients receiving the polymer-free sirolimus-eluting stent system YUKON-Choice (Yukon-DES, Translumina, Germany). From 01/2006-09/2008 all patients receiving Yukon-DES (≥2.5 mm diameter) were prospectively enrolled in our registry. The primary endpoint was long-term major adverse cardiac events (MACE). 701 patients were included in our registry. Mean age was 65.7 ± 10 years (73% male gender, 35.5% diabetes, and 32.2% acute coronary syndrome). 76% of the lesions were of Type B2/C. Lesion length was 24.6 ± 5.2 mm and mean stent diameter was 2.8 ± 0.4 mm. A total of 511 pts (72%) underwent 6-months angiographic follow-up, target vessel revascularization was noted in 23.5%. At 5 years clinical outcomes were: cardiac death 5.8%; myocardial infarction 3.4%; and TVR 24.6%. The incidence of MACE differed significantly between "on-label" and "off-label" indications (14.8% vs. 40.8% MACE; P 1 year) ST occurred in 0.29%. Our data suggests that the implantation of the sirolimus-coated polymer-free YUKON-DES is safe and feasible with a very low incidence of ST in this real world patient cohort with high percentage of diabetes and small vessels. © 2013 Wiley Periodicals, Inc.

  10. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    Science.gov (United States)

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  11. Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: A multislice computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Tsuyoshi [Toyohashi Heart Center, Oyama-cho, Toyohashi (Japan); Nagoya City University Graduate School of Medical Sciences, Department of Cardio-Renal Medicine and Hypertension, Nagoya (Japan); Kimura, Masashi; Ehara, Mariko; Terashima, Mitsuyasu; Nasu, Kenya; Kinoshita, Yoshihisa; Habara, Maoto; Tsuchikane, Etsuo; Suzuki, Takahiko [Toyohashi Heart Center, Oyama-cho, Toyohashi (Japan)

    2014-05-15

    This study sought to evaluate the impact of sirolimus-eluting stent (SES) fractures on long-term clinical outcomes using multislice computed tomography (MSCT). In this study, 528 patients undergoing 6- to 18-month follow-up 64-slice MSCT after SES implantation without early clinical events were followed clinically (the median follow-up interval was 4.6 years). A CT-detected stent fracture was defined as a complete gap with Hounsfield units (HU) <300 at the site of separation. The major adverse cardiac events (MACEs), including cardiac death, stent thrombosis, and target lesion revascularisation, were compared according to the presence of stent fracture. Stent fractures were observed in 39 patients (7.4 %). MACEs were more common in patients with CT-detected stent fractures than in those without (46 % vs. 7 %, p < 0.01). Univariate Cox regression analysis indicated a significant relationship between MACE and stent fracture [hazard ratio (HR) 7.65; p < 0.01], age (HR 1.03; p = 0.04), stent length (HR 1.03; p < 0.01), diabetes mellitus (HR 1.77; p = 0.04), and chronic total occlusion (HR 2.54; p = 0.01). In the multivariate model, stent fracture (HR 5.36; p < 0.01) and age (HR 1.03; p = 0.04) remained significant predictors of MACE. An SES fracture detected by MSCT without early clinical events was associated with long-term clinical adverse events. (orig.)

  12. Satisfactory arterial repair 1 year after ultrathin strut biodegradable polymer sirolimus-eluting stent implantation: an angioscopic observation.

    Science.gov (United States)

    Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki

    2018-01-15

    The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.

  13. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.

    Science.gov (United States)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego; Stettler, Christoph; Sangiorgi, Diego; D'Ascenzo, Fabrizio; Kimura, Takeshi; Briguori, Carlo; Sabatè, Manel; Kim, Hyo-Soo; De Waha, Antoinette; Kedhi, Elvin; Smits, Pieter C; Kaiser, Christoph; Sardella, Gennaro; Marullo, Antonino; Kirtane, Ajay J; Leon, Martin B; Stone, Gregg W

    2012-04-14

    The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents. For this network meta-analysis, randomised controlled trials comparing different drug-eluting stents or drug-eluting with bare-metal stents currently approved in the USA were identified through Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. 49 trials including 50,844 patients randomly assigned to treatment groups were analysed. 1-year definite stent thrombosis was significantly lower with cobalt-chromium everolimus eluting stents (CoCr-EES) than with bare-metal stents (odds ratio [OR] 0·23, 95% CI 0·13-0·41). The significant difference in stent thrombosis between CoCr-EES and bare-metal stents was evident as early as 30 days (OR 0·21, 95% CI 0·11-0·42) and was also significant between 31 days and 1 year (OR 0·27, 95% CI 0·08-0·74). CoCr-EES were also associated with significantly lower rates of 1-year definite stent thrombosis compared with paclitaxel-eluting stents (OR 0·28, 95% CI 0·16-0·48), permanent polymer-based sirolimus-eluting stents (OR 0·41, 95% CI 0·24-0·70), phosphorylcholine-based zotarolimus-eluting stents (OR 0·21, 95% CI 0·10-0·44), and Resolute zotarolimus-eluting stents (OR 0·14, 95% CI 0·03-0·47). At 2-year follow-up, CoCr-EES were still associated with significantly lower rates of definite stent thrombosis than were bare-metal (OR 0·35, 95% CI 0·17-0·69) and paclitaxel-eluting stents (OR 0·34, 95% CI 0·19-0·62). No other drug-eluting stent had lower definite thrombosis rates compared with bare

  14. A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy

    International Nuclear Information System (INIS)

    Jiménez, Victor A.; Iñiguez, Andrés; Baz, José A.; Valdés, Mariano; Ortiz, Alberto; Vuilliomenet, André; Mainar, Vicente; Dudek, Dariusz; Banai, Shmuel; Tüller, David; Bonnet, Jean-Louis; De Miguel, Antonio; Bastos, Guillermo; Wijns, William; Saito, Shigeru

    2016-01-01

    Background: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial. Methods: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9 month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24 months. Results: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24 months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P = 0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P = 0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate. Conclusions: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up. - Highlights: • This study reported the 24-month clinical outcomes of new-generation BP-SES compared with PP-EES in ACS subgroup from CENTURY II study. • This is a pre-specified subgroup analysis of a large randomized, prospective, multicenter clinical trial. • The BP-SES showed good and comparable clinical performance as PP-EES at 24 months. • This substudy has a relatively small sample size and

  15. A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy

    Energy Technology Data Exchange (ETDEWEB)

    Jiménez, Victor A., E-mail: victor.alfonso.jimenez.diaz@sergas.es [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Iñiguez, Andrés; Baz, José A. [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Valdés, Mariano [Hospital Universitario V. Arrixaca, Murcia (Spain); Ortiz, Alberto [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Vuilliomenet, André [Kantonsspital Aarau, Aarau (Switzerland); Mainar, Vicente [Department of Cardiology, University General Hospital of Alicante, Alicante (Spain); Dudek, Dariusz [Department of Interventional Cardiology, Jagiellonian University Medical College, Krakow (Poland); Banai, Shmuel [Tel Aviv Sourasky Medical Centre, Tel Aviv (Israel); Tüller, David [Department of Cardiology, Stadtspital Triemli, Zürich (Switzerland); Bonnet, Jean-Louis [Department of Cardiology, Hospital La Timone, Marseille (France); De Miguel, Antonio; Bastos, Guillermo [Interventional Cardiology Unit, Cardiology Department, Hospital Alvaro Cunqueiro, University Hospital of Vigo, Vigo (Spain); Wijns, William [Cardiovascular Center Aalst, OLV Hospital, Aalst (Belgium); Saito, Shigeru [Department of Cardiology and Catheterization Laboratory, Shonan Kamakura General Hospital, Kamakura (Japan)

    2016-09-15

    Background: To investigate clinical outcomes of percutaneous coronary intervention using a sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES) compared with a permanent polymer everolimus-eluting stent, Xience (PP-EES) in patients with high risk (ST-segment elevation and non-ST-segment elevation myocardial infarction) acute coronary syndromes (ACS) enrolled in the CENTURY II trial. Methods: CENTURY II is a prospective, multicenter, randomized, single blind, controlled trial comparing BP-SES and PP-EES, with primary endpoint of target lesion failure (TLF) at 9 month post-stent implantation. Out of 1123 patients enrolled in CENTURY II trial, 264 high risk ACS patients were included in this subgroup analysis, and the clinical outcomes including target lesion failure (TLF), target vessel failure (TVF), cardiac death, myocardial infarction, and stent thrombosis were evaluated at 24 months. Results: The baseline clinical, angiographic and procedural characteristics were similar between two groups. At 24 months, TLF occurred in 6.3% of patients receiving a BP-SES and 6.5% of patients receiving a PP-EES (P = 0.95); TVF was 6.3% in patients receiving a BP-SES and 9.4% in patients receiving a PP-EES (P = 0.36). There were no significant differences in cardiac death, myocardial infarction and stent thrombosis rate. Conclusions: BP-SES achieved similar safety and efficacy outcomes as PP-EES in this ACS subgroup of CENTURY II study, at 24-month follow-up. This finding is hypothesis-generating and needs to be confirmed in larger trials with longer follow-up. - Highlights: • This study reported the 24-month clinical outcomes of new-generation BP-SES compared with PP-EES in ACS subgroup from CENTURY II study. • This is a pre-specified subgroup analysis of a large randomized, prospective, multicenter clinical trial. • The BP-SES showed good and comparable clinical performance as PP-EES at 24 months. • This substudy has a relatively small sample size and

  16. In vitro pharmacokinetics of sirolimus-coated stent for tracheal stenosis

    African Journals Online (AJOL)

    Further increases in sirolimus: PLGA ratio did not improve stent drug loading. A slow release of ... tracheal stent can damage the airway mucosa, and cause .... Figure 3: Cumulative drug release from sirolimus-coated stents. DISCUSSION.

  17. Mechanisms and Patterns of Intravascular Ultrasound In-Stent Restenosis Among Bare Metal Stents and First- and Second-Generation Drug-Eluting Stents.

    Science.gov (United States)

    Goto, Kosaku; Zhao, Zhijing; Matsumura, Mitsuaki; Dohi, Tomotaka; Kobayashi, Nobuaki; Kirtane, Ajay J; Rabbani, LeRoy E; Collins, Michael B; Parikh, Manish A; Kodali, Susheel K; Leon, Martin B; Moses, Jeffrey W; Mintz, Gary S; Maehara, Akiko

    2015-11-01

    The most common causes of in-stent restenosis (ISR) are intimal hyperplasia and stent under expansion. The purpose of this study was to use intravascular ultrasound (IVUS) to compare the ISR mechanisms of bare metal stents (BMS), first-generation drug-eluting stents (DES), and second-generation DES. There were 298 ISR lesions including 52 BMS, 73 sirolimus-eluting stents, 52 paclitaxel-eluting stents, 16 zotarolimus-eluting stents, and 105 everolimus-eluting stent. Mean patient age was 66.6 ± 1.1 years, 74.2% were men, and 48.3% had diabetes mellitus. BMS restenosis presented later (70.0 ± 66.7 months) with more intimal hyperplasia compared with DES (BMS 58.6 ± 15.5%, first-generation DES 52.6 ± 20.9%, second-generation DES 48.2 ± 22.2%, p = 0.02). Although reference lumen areas were similar in BMS and first- and second-generation DES, restenotic DES were longer (BMS 21.8 ± 13.5 mm, first-generation DES 29.4 ± 16.1 mm, second-generation DES 32.1 ± 18.7 mm, p = 0.003), and stent areas were smaller (BMS 7.2 ± 2.4 mm(2), first-generation DES 6.1 ± 2.1 mm(2), second-generation DES 5.7 ± 2.0 mm(2), p Stent fracture was seen only in DES (first-generation DES 7 [5.0%], second-generation DES 8 [7.4%], p = 0.13). In conclusion, restenotic first- and second-generation DES were characterized by less neointimal hyperplasia, smaller stent areas, longer stent lengths, and more stent fractures than restenotic BMS. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  19. Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent : 4-year results of the PROTECT randomized trial

    NARCIS (Netherlands)

    Wijns, William; Steg, Ph. Gabriel; Mauri, Laura; Kurowski, Volkhard; Parikh, Keyur; Gao, Runlin; Bode, Christoph; Greenwood, John P.; Lipsic, Erik; Alamgir, Farqad; Rademaker-Havinga, Tessa; Boersma, Eric; Radke, Peter; van Leeuwen, Frank; Camenzind, Edoardo

    2014-01-01

    Aims To compare the long-term clinical safety between two drug-eluting stents with different healing characteristics in the Patient Related Outcomes with Endeavour (E-ZES) vs. Cypher (C-SES) Stenting Trial (PROTECT). At 3 years, there was no difference in the primary outcome of definite or probable

  20. Meta-Analysis of Randomized Clinical Trials Comparing Biodegradable Polymer Drug-Eluting Stent to Second-Generation Durable Polymer Drug-Eluting Stents.

    Science.gov (United States)

    El-Hayek, Georges; Bangalore, Sripal; Casso Dominguez, Abel; Devireddy, Chandan; Jaber, Wissam; Kumar, Gautam; Mavromatis, Kreton; Tamis-Holland, Jacqueline; Samady, Habib

    2017-03-13

    The authors sought to perform a meta-analysis of randomized clinical trials (RCTs) comparing the safety and efficacy of biodegradable polymer drug-eluting stents (BP-DES) to second-generation durable polymer drug-eluting stents (DP-DES). Prior meta-analyses have established the superiority of BP-DES over bare-metal stents and first-generation DP-DES; however, their advantage compared with second-generation DP-DES remains controversial. The authors searched PubMed and Scopus databases for RCTs comparing BP-DES to the second-generation DP-DES. Outcomes included target vessel revascularization (TVR) as efficacy outcome and cardiac death, myocardial infarction (MI), and definite or probable stent thrombosis (ST) as safety outcomes. In addition, we performed landmark analysis for endpoints beyond 1 year of follow-up and a subgroup analysis based on the stent characteristics. The authors included 16 RCTs comprising 19,886 patients in the meta-analysis. At the longest available follow-up (mean duration 26 months), we observed no significant differences in TVR (p = 0.62), cardiac death (p = 0.46), MI (p = 0.98), or ST (risk ratio: 0.83, 95% confidence interval: 0.64 to 1.09; p = 0.19). Our landmark analysis showed that BP-DES were not associated with a reduction in the risk of very late ST (risk ratio: 0.87, 95% confidence interval: 0.49 to 1.53; p = 0.62). Similar outcomes were seen regardless of the eluting drug (biolimus vs. sirolimus), the stent platform (stainless steel vs. alloy), the kinetics of polymer degradation or drug release (6 months), the strut thickness of the BP-DES (thin 100 μm), or the DAPT duration (≥6 months vs. ≥12 months). BP-DES have similar safety and efficacy profiles to second-generation DP-DES. Published by Elsevier Inc.

  1. Comparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice: the SORT OUT II randomized trial

    DEFF Research Database (Denmark)

    Galløe, Anders M; Thuesen, Leif; Kelbaek, Henning

    2008-01-01

    Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients.......Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients....

  2. Safety and efficacy of everolimus-eluting stents for bare-metal in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Torguson, Rebecca; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-04-15

    Objective: The aim of this study was to compare the safety and efficacy of the everolimus-eluting stents (EES) with the paclitaxel-eluting stent (PES) and sirolimus-eluting stent (SES) for the treatment of bare-metal in-stent restenosis. Background: The optimal treatment for bare-metal in-stent restenosis remains controversial. Methods: The study cohort comprised 322 consecutive patients (543 lesions) who presented with bare-metal in-stent restenosis to our institution and underwent coronary artery stent implantation with EES (114 patients; 181 lesions), PES (65 patients; 116 lesions) and SES (143 patients; 246 lesions). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac events (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors except for age and chronic kidney disease. The 1-year analyzed clinical parameters were similar in the three groups: death (EES = 3.5%, PES = 4.6%, SES = 4.2%; p = 0.94), MI (EES = 3.5%, PES = 6.3%, SES = 2.1%; p = 0.31), TLR (EES = 9.8%, PES = 9.5%, SES = 5.7%; p = 0.42), TVR (EES = 14.3%, PES = 11.1%, SES = 11.3%; p = 0.74), definite ST (EES = 0.9%, PES = 3.1%, SES = 3.5%; p = 0.38) and MACE (EES = 14.0%, PES = 15.4%, SES = 10.5%; p = 0.54). Male gender (hazard ratio = 0.47; 95% confidence interval = 0.25–0.88) and number of treated lesions (hazard ratio = 1.47; 95% confidence interval = 1.06–2.05) were found to be independent predictors of MACE. Conclusion: The results of the present study indicate that EES may provide similar safety and efficacy as first generation DES for the treatment of patients presenting with bare-metal in-stent restenosis.

  3. Effect of oral sirolimus therapy on inflammatory biomarkers following coronary stenting

    Directory of Open Access Journals (Sweden)

    W.C.M. Rosa

    2010-08-01

    Full Text Available We studied the effect of oral sirolimus, administered to prevent and treat in-stent restenosis (ISR, on the variation of serum levels of inflammatory markers following coronary stenting with bare metal stents. The mean age of the patients was 56 ± 13 years, 65% were males and all had clinically manifested ischemia. Serum levels of high sensitivity C-reactive protein (hs-CRP concentration were determined by chemiluminescence and serum levels of all other biomarkers by ELISA. One group of patients at high risk for ISR received a loading oral dose of 15 mg sirolimus and 5 mg daily thereafter for 28 days after stenting (SIR-G. A control group (CONT-G was submitted to stenting without sirolimus therapy. The increase in hs-CRP concentration was highest at 24 h after stenting in both groups. A significant difference between SIR-G and CONT-G was observed at 4 weeks (-1.50 ± 5.0 vs -0.19 ± 0.4, P = 0.008 and lost significance 1 month after sirolimus discontinuation (-1.73 ± 4.3 vs -0.01 ± 0.7, P = 0.0975. A continuous fall in MMP-9 concentration was observed in SIR-G, with the greatest reduction at 4 weeks (-352.9 ± 455 vs +395.2 ± 377, P = 0.0004, while a positive variation was noted 4 weeks after sirolimus discontinuation (227 ± 708 vs 406.2 ± 472.1, P = 0.0958. SIR-G exhibited a higher increase in P-selectin after sirolimus discontinuation at week 8 (46.1 ± 67.9 vs 5.8 ± 23.7, P = 0.0025. These findings suggest that the anti-restenotic actions of systemic sirolimus include anti-proliferative effects and modulation of the inflammatory response with inhibition of adhesion molecule expression.

  4. Coated stents to prevent restenosis in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2005-11-01

    Full Text Available Background: In-stent-restenosis (ISR is considered to be an essential limiting factor of stenting in coronary heart disease (CHD. The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. Objectives: The present analysis addresses the questions on medical effectiveness and cost-effectiveness of the use of various coated stent types in CHD. Methods: The literature was searched in December 2004 in the most relevant medical and economic databases. The medical evaluation was conducted on the basis of published RCT. The data from the studies regarding various angiographic, sonographic and clinical endpoints were checked for methodical quality and summarised in meta-analyses. Within the scope of economic evaluation the primary studies were analysed and modelling was performed, applying clinical effect estimates from the meta-analyses of the medical evaluation and current estimates of German costs. Results: Medical evaluation: Ten different stenttypes were used in the included 26 RCT. The results for heparin, silicon-carbide, carbon and PTFE coated stenttypes could not reveal any significant differences between the medical effectiveness of coated and uncoated stents. The application of sirolimus, paclitaxel, everolimus and 7-hexanoyltaxol eluting stents showed a significant lower restenosis at 6-9 months with decrease in the rate of restenosis for polymer-based sirolimus, paclitaxel and 7-hexanoyltaxol eluting stents. In contrast, the use of gold-coated and actinomycin-D eluting stents was associated with a significantly higher restenosis. The polymer-based sirolimus and paclitaxel eluting stents also showed a significant and considerable reduction in the rate of repeated percutaneous revascularisations at 6-12 months (3.5% vs. 19.7%; p<0.0001, RR=0.19 [95%CI: 0.11; 0.33] and 3.5% vs. 12.2%; p<0.0001, RR=0.30 [95%CI: 0

  5. The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis)

    DEFF Research Database (Denmark)

    Verheye, Stefan; Vrolix, Mathias; Kumsars, Indulis

    2017-01-01

    centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. RESULTS Procedural success in the intention-to-treat population was 100 The primary safety endpoint was target lesion failure (TLF) (cardiac death...... and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. CONCLUSIONS This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes...

  6. Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model

    Science.gov (United States)

    Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun

    2018-01-01

    Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643

  7. Stent thrombosis and bleeding complications after implantation of sirolimus-eluting coronary stents in an unselected worldwide population: a report from the e-SELECT (Multi-Center Post-Market Surveillance) registry.

    Science.gov (United States)

    Urban, Philip; Abizaid, Alexandre; Banning, Adrian; Bartorelli, Antonio L; Baux, Ana Cebrian; Džavík, Vladimír; Ellis, Stephen; Gao, Runlin; Holmes, David; Jeong, Myung Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Spaulding, Christian; Worthley, Stephen

    2011-03-29

    The aim of this study was to ascertain the 1-year incidence of stent thrombosis (ST) and major bleeding (MB) in a large, unselected population treated with sirolimus-eluting stents (SES). Stent thrombosis and MB are major potential complications of drug-eluting stent implantation. Their relative incidence and predisposing factors among large populations treated worldwide are unclear. The SES were implanted in 15,147 patients who were entered in a multinational registry. We analyzed the incidence of: 1) definite and probable ST as defined by the Academic Research Consortium; and 2) MB, with the STEEPLE (Safety and efficacy of Enoxaparin in PCI) definition, together with their relation to dual antiplatelet therapy (DAPT) and to 1-year clinical outcomes. The mean age of the sample was 62 ± 11 years, 30.4% were diabetic, 10% had a Charlson comorbidity index ≥3, and 44% presented with acute coronary syndrome or myocardial infarction. At 1 year, the reported compliance with DAPT as recommended by the European Society of Cardiology guidelines was 86.3%. Adverse event rates were: ST 1.0%, MB 1.0%, mortality 1.7%, myocardial infarction 1.9%, and target lesion revascularization 2.3%. Multivariate analysis identified 9 correlates of ST and 4 correlates of MB. Advanced age and a high Charlson index were associated with an increased risk of both ST and MB. After ST, the 7-day and 1-year all-cause mortality was 30% and 35%, respectively, versus 1.5% and 10% after MB. Only 2 of 13,749 patients (0.015%) experienced both MB and ST during the entire 1-year follow-up period. In this worldwide population treated with ≥1 SES, the reported compliance with DAPT was good, and the incidence of ST and MB was low. Stent thrombosis and MB very rarely occurred in the same patient. (The e-SELECT Registry: a Multicenter Post-Market Surveillance; NCT00438919). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Transient coronary aneurysm formation after Nevo™ stent implantation versus persistent coronary aneurysm after Cypher Select™ stent implantation

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Lassen, Jens Flensted; Jensen, Lisette Okkels

    2011-01-01

    We implanted a Cypher Select™ coronary stent and two months later a Nevo™ sirolimus-eluting coronary stent in another vessel. At a prescheduled angiographic follow-up, coronary aneurysms were seen in the two stented segments, 6 and 8 months after stent implantation, respectively. Six months later......, the aneurysm had healed in the Nevo, but was still present in the Cypher stented segment. We hypothesize that aneurysm formation was induced by sirolimus and the polymer of the implanted stents, and that subsequent healing was possible in the Nevo stent after degradation of the polymer....

  9. Enhanced drug delivery capabilities from stents coated with absorbable polymer and crystalline drug

    OpenAIRE

    Carlyle, Wenda C.; McClain, James B.; Tzafriri, Abraham R.; Bailey, Lynn; Zani, Brett G.; Markham, Peter M.; Stanley, James R.L.; Edelman, Elazer R.

    2012-01-01

    Current drug eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug delivery. A novel, absorbable-coating sirolimus-eluting stent (AC-SES) was evaluated for its capacity to deliver drug more evenly within the intimal area rather than concentrating drug around the stent struts and for its ability to match coating erosion with drug release. The coating consisted of absorbable poly-lactide-co-glycolic acid (PLGA) and crystalline sirolimus deposited by a dry-p...

  10. Drug-eluting stents for acute coronary syndrome: a meta-analysis of randomized controlled trials.

    Directory of Open Access Journals (Sweden)

    Lishan Wang

    Full Text Available Drug-eluting stents (DES are increasingly used for treatment of acute coronary syndrome (ACS. However, clinical efficacy and safety of various types of DES is not well established in these subjects. We therefore evaluated clinical utility of second-generation and first-generation DES in patients with ACS by conducting a meta-analysis.A search of Medline, Embase, the Cochrane databases, and Web of Science was made. Randomized controlled trials (RCTs which compared second-generation DES (everolimus-eluting stents [EES] or zotarolimus-eluting stents [ZES] versus first-generation DES (sirolimus-eluting stents [SES] or paclitaxe-eluting stents [PES] in patients with ACS and provided data on clinical efficacy or safety endpoints were included. Pooled estimates were calculated using random-effects model.A total of 2,757 participants with ACS in 6 RCTs were included. Compared with first-generation one, second-generation DES trended to be associated with the decreased incidence of definite or probable stent thrombosis in ACS patients (risk ratio [RR]  = 0.60, 95% confidence intervals [CI] 0.33 to 1.07, p = 0.09. However, the rate of target lesion revascularization (TLR significantly increased in second-generation DES (RR = 2.08, 95%CI 1.25 to 3.47, p = 0.005. There were no significant differences in the incidence of major adverse cardiac events (MACEs, all-cause death, cardiac death, and recurrent myocardial infarction between the two arms (all p>0.10. The second-generation EES showed a tendency towards lower risk of MACEs (p = 0.06 and a beneficial effect on reducing stent thrombosis episodes (p = 0.009, while the second-generation ZES presented an increased occurrence of MACEs (p = 0.02 and TLR (p = 0.003.Second-generation DES, especially EES, appeared to present a lower risk of stent thrombosis, whereas second-generation ZES might increase the need for repeat revascularization in ACS patients. During coronary

  11. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.

    Science.gov (United States)

    Parsa, Ehsan; Saroukhani, Sepideh; Majlessi, Fereshteh; Poorhosseini, Hamidreza; Lofti-Tokaldany, Masoumeh; Jalali, Arash; Salarifar, Mojtaba; Nematipour, Ebrahim; Alidoosti, Mohammad; Aghajani, Hassan; Amirzadegan, Alireza; Kassaian, Seyed Ebrahim

    2016-04-01

    We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent.

  12. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    Science.gov (United States)

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  13. Direct implantation of rapamycin-eluting stents with bioresorbable drug carrier technology utilising the Svelte coronary stent-on-a-wire: the DIRECT II study.

    Science.gov (United States)

    Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W

    2016-08-05

    Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.

  14. The effect of solvents and hydrophilic additive on stable coating and controllable sirolimus release system for drug-eluting stent.

    Science.gov (United States)

    Kim, Seong Min; Park, Sung-Bin; Bedair, Tarek M; Kim, Man-Ho; Park, Bang Ju; Joung, Yoon Ki; Han, Dong Keun

    2017-09-01

    Various drug-eluting stents (DESs) have been developed to prevent restenosis after stent implantation. However, DES still needs to improve the drug-in-polymer coating stability and control of drug release for effective clinical treatment. In this study, the cobalt-chromium (CoCr) alloy surface was coated with biodegradable poly(D,L-lactide) (PDLLA) and sirolimus (SRL) mixed with hydrophilic Pluronic F127 additive by using ultrasonic spray coating system in order to achieve a stable coating surface and control SRL release. The degradation of PDLLA/SRL coating was studied under physiological solution. It was found that adding F127 reduced the degradation of PDLLA and improved the coating stability during 60days. The effects of organic solvent such as chloroform and tetrahydrofuran (THF) on the coating uniformity were also examined. It was revealed that THF produced a very smooth and uniform coating compared to chloroform. The patterns of in vitro drug release according to the type of organic solvent and hydrophilic additive proposed the possibility of controllable drug release design in DES. It was found that using F127 the drug release was sustained regardless of the organic solvent used. In addition, THF was able to get faster and controlled release profile when compared to chloroform. The structure of SRL molecules in different organic solvents was investigated using ultra-small angle neutron scattering. Furthermore, the structure of SRL is concentration-dependent in chloroform with tight nature under high concentration, but concentration-independent in THF. These results strongly demonstrated that coating stability and drug release patterns can be changed by physicochemical properties of various parameters such as organic solvents, additive, and coating strategy. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Dual-therapy stent technology for patients with coronary artery disease : A great catch?

    NARCIS (Netherlands)

    Kalkman, D.N.

    2018-01-01

    This thesis investigates the possible advantages of a new stent technology that aims to improve care for patients with coronary artery disease. The COMBO stent (OrbusNeich Medical BV, The Netherlands) contains a dual-therapy stent technology. The stent combines two techniques: a sirolimus-elution

  16. Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.

    Science.gov (United States)

    Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T

    2006-01-01

    To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.

  17. 3-Year Clinical Follow-Up of the RIBS IV Clinical Trial: A Prospective Randomized Study of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis in Coronary Arteries Previously Treated With Drug-Eluting Stents.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; Cuesta, Javier; García Del Blanco, Bruno; García-Touchard, Arturo; López-Mínguez, José Ramón; Masotti, Mónica; Zueco, Javier; Cequier, Angel; Velázquez, Maite; Moreno, Raúl; Mainar, Vicente; Domínguez, Antonio; Moris, Cesar; Molina, Eduardo; Rivero, Fernando; Jiménez-Quevedo, Pilar; Gonzalo, Nieves; Fernández-Pérez, Cristina

    2018-05-28

    This study sought to compare the long-term safety and efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients with in-stent restenosis (ISR) of drug-eluting stents (DES). Treatment of patients with DES-ISR remains a challenge. The RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents) trial is a prospective multicenter randomized clinical trial comparing DEB and EES in patients with DES-ISR. The pre-specified comparison of the 3-year clinical outcomes obtained with these interventions is the main objective of the present study. A total of 309 patients with DES-ISR were randomized to DEB (n = 154) or EES (n = 155). At angiographic follow-up, the in-segment minimal lumen diameter was larger in the EES arm (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p 1 year) target lesion revascularization (2.6% vs. 4%) and target vessel revascularization (4% vs. 6.6%) was similar in the 2 arms. Rates of cardiac death (3.9% vs. 3.2%), myocardial infarction (2.6% vs. 4.5%), and stent thrombosis (1.3% vs. 2.6%) at 3 years were also similar in both arms. The 3-year clinical follow-up of this randomized clinical trial demonstrates that in patients with DES-ISR, EES reduce the need for repeat interventions compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloons vs Everolimus-Eluting Stents [RIBS IV]; NCT01239940). Published by Elsevier Inc.

  18. Zotarolimus-eluting durable-polymer-coated stent versus a biolimus-eluting biodegradable-polymer-coated stent in unselected patients undergoing percutaneous coronary intervention (SORT OUT VI)

    DEFF Research Database (Denmark)

    Raungaard, Bent; Jensen, Lisette Okkels; Tilsted, Hans-Henrik

    2015-01-01

    BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety...... and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All......-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat...

  19. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    Science.gov (United States)

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  20. Meta-analysis comparing efficacy and safety of first generation drug-eluting stents to bare-metal stents in patients with diabetes mellitus undergoing primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian

    2013-01-01

    revascularization (hazard ratio 0.42, 95% confidence interval 0.29 to 0.59, p 1 year) with DES. In conclusion, this meta-analysis, based on individual patients' data from 11 randomized trials, showed that among patients with diabetes with STEMIs who undergo primary percutaneous coronary intervention, sirolimus...... with high rates of target vessel revascularization after bare-metal stent (BMS) implantation but also higher rates of ST after DES implantation. Therefore, the aim of this study was to perform a meta-analysis of individual patients' data to evaluate the long-term safety and effectiveness of DES compared......Several concerns have emerged regarding the higher risk for stent thrombosis (ST) after drug-eluting stent (DES) implantation, especially in the setting of ST-segment elevation myocardial infarction (STEMI). Few data have been reported so far in patients with diabetes mellitus, which is associated...

  1. Association of Adventitial Vasa Vasorum and Inflammation With Coronary Hyperconstriction After Drug-Eluting Stent Implantation in Pigs In Vivo.

    Science.gov (United States)

    Nishimiya, Kensuke; Matsumoto, Yasuharu; Shindo, Tomohiko; Hanawa, Kenichiro; Hasebe, Yuhi; Tsuburaya, Ryuji; Shiroto, Takashi; Takahashi, Jun; Ito, Kenta; Ishibashi-Ueda, Hatsue; Yasuda, Satoshi; Shimokawa, Hiroaki

    2015-01-01

    The importance of adventitial inflammation has been implicated for the pathogenesis of coronary artery disease. However, the roles of adventitial changes in drug-eluting stent (DES)-induced coronary hyperconstriction remain largely unknown. In the present study, this issue in pigs in vivo with a special reference to adventitial vasa vasorum (VV) formation and Rho-kinase activation, a central mechanism of coronary vasospasm, was examined. Each animal received a sirolimus-eluting stent (SES) and a biolimus A9-eluting stent (BES), one in the left anterior descending and another in the left circumflex coronary arteries in a randomized manner (n=18). After 1, 3 and 6 months, coronary vasomotion was examined. At 1 month, coronary vasoconstriction to serotonin was significantly enhanced at the SES edges as compared with the BES edges (SES, 52±7% vs. BES, 22±3%, Pmicro-CT showed VV augmentation at the SES site, extending to the proximal and distal edges. Immunostainings demonstrated that VV formation, macrophage infiltration in the adventitia and Rho-kinase expressions/activation were significantly enhanced at the SES edges as compared with the BES edges. The DES with durable polymers enhances VV formation and inflammation in the adventitia, associating with the pathogenesis of DES-induced coronary hyperconstriction through Rho-kinase activation in pigs in vivo.

  2. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  3. All-cause mortality after drug-eluting stent implantation in African-Americans.

    Science.gov (United States)

    Poludasu, Shyam; Cavusoglu, Erdal; Khan, Waqas; Marmur, Jonathan D

    2008-12-01

    Recent studies have questioned the safety of drug-eluting stents because of a higher incidence of late stent thrombosis, raising the possibility that drug-eluting stents may be associated with an increased mortality. The effect of drug-eluting stents on mortality in African-Americans is unknown. We evaluated 628 African-American patients (354 patients treated with drug-eluting stents and 274 patients treated with bare metal stents) between January 2003 and August 2005, using data from our bolus-only platelet glycoprotein IIb/IIIa inhibitor database. The primary end point was all-cause mortality obtained using social security death index. After a mean follow-up of 3+/-0.9 years, the mortality rate in the bare metal stents group was 12.8% compared with 7.1% in the drug-eluting stents group [adjusted P value=0.19; hazard ratio (HR) for bare metal stents group compared with drug-eluting stents group for death=1.4; 95% confidence interval (CI): 0.8-2.4]. In a subgroup analysis, patients presenting with acute coronary syndrome had a higher mortality when treated with bare metal stents compared with drug-eluting stents (17.1 vs. 6.3%, P=0.022; HR=2.2; 95% CI: 1.1-4.4). Patients with chronic kidney disease (all patients with creatinine >1.5 mg/dl) also had a higher mortality with bare metal stents compared with drug-eluting stents (36.7 vs. 20.4%, P=0.044; HR=2.3; 95% CI: 1.02-5.2). Drug-eluting stents seem to be safe in African-Americans and may improve survival in certain subgroups such as patients with acute coronary syndromes and chronic kidney disease.

  4. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  5. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent

    DEFF Research Database (Denmark)

    Stone, Gregg W; Teirstein, Paul S; Meredith, Ian T

    2011-01-01

    We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI).......We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI)....

  6. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    DEFF Research Database (Denmark)

    Raungaard, Bent; Christiansen, Evald H; Bøtker, Hans Erik

    2017-01-01

    artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion......OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first......-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary...

  7. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    Science.gov (United States)

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  8. Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents

    DEFF Research Database (Denmark)

    Andreasen, Lene N; Holm, Niels R; Balleby, Ida R

    2018-01-01

    -inferiority (Δ = 0.60 mm2) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro (n = 60) or Nobori (n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.......26 mm2, but increased to 0.82 mm2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm2 [0.02;0.30] mm2, Nobori: 0.03 mm2 [0.00;0.17] mm2, P = 0.......04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98,6]% (P = 0.13). Conclusion: Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution...

  9. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    Science.gov (United States)

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the

  10. Propensity score matched lesion-based comparison of long-term clinical and angiographic outcomes after placement of sirolimus (Cypher Bx Velocity) and paclitaxel (TAXUS Express)-eluting stents for de novo native coronary stenosis.

    Science.gov (United States)

    Nakano, Yosuke; Ishikawa, Tetsuya; Hino, Shoryoku; Mutoh, Makoto

    2014-04-01

    Long-term clinical and angiographic outcomes after sirolimus (SES: Cypher Bx Velocity) and paclitaxel (PES: TAXUS Express)-eluting stent implantation were firstly compared in Japan. During PES-available period from May 2007 to February 2009, 1068 nonrandomized consecutive de novo native coronary lesions treated either with a PES (682 lesions) or SES were enrolled in this study, and a retrospective examination was conducted in April 2013. During that interval, the use ratio of drug-eluting stent (i.e. SES plus PES) was 94.2 %. By adjusting the baselines with a propensity score matching analysis produced 383 lesions in each arm, the incidence of the clinical endpoint (1500-day cardiac death, nonfatal recurrent myocardial infarction, and definite stent thrombosis) after placement of SES (2.1 %; mean follow-up, 1400 ± 290 days) was not significantly different from that in the PES group (2.6 %; 1394 ± 325 days, p = 0.637). SES did not relate to the clinical endpoint (hazard ratio 1.04; 95 % CI 0.29-3.76; p = 0.949). In the baseline-adjusted angiographic followed up lesions (n = 234 in each arm), the incidence of binary restenosis (percent diameter stenosis [%DS] >50 %) in the SES group (12.0 %; mean follow-up, 477 ± 281 days) was not significantly different from that in the PES group (14.5 %; 497 ± 341 days, p = 0.431). SES did not relate to binary restenosis (Odds ratio 0.73; 95 % CI 0.40-1.32; p = 0.295). In conclusion, the present propensity score matched lesion-based analysis firstly showed the statistical equivalent long-term clinical and angiographic outcomes after either SES or PES placement for de novo native coronary lesion in Japanese patients in a daily practice environment.

  11. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  12. Local delivery of sirolimus nanoparticles for the treatment of in-stent restenosis.

    Science.gov (United States)

    Zago, Alexandre C; Raudales, José C; Attizzani, Guilherme; Matte, Bruno S; Yamamoto, German I; Balvedi, Julise A; Nascimento, Ludmila; Kosachenco, Beatriz G; Centeno, Paulo R; Zago, Alcides J

    2013-02-01

    To test the local delivery of sirolimus nanoparticles following percutaneous transluminal coronary angioplasty (PTCA) to treat in-stent restenosis (ISR) in a swine model. Coronary bare-metal stent (BMS) implantation reduces major adverse cardiac events when compared with PTCA; however, ISR rates remain high. Eighteen swine underwent BMS deployment guided by intravascular ultrasound (IVUS). Of these, 16 developed ISR (1 stent/swine) and underwent angioplasty with a noncompliant balloon (PTCA-NC). The animals were then randomized into four groups for local infusion of sirolimus nanoparticles through a porous balloon catheter, as follows: (1) PTCA-NC alone (control); (2) PTCA-NC + (polylactic acid)-based nanoparticle formulation (anionic 1); (3) PTCA-NC + (polylactic-co-glycolic acid)-based nanoparticle formulation (anionic 2); and (4) PTCA-NC + Eudragit RS nanoparticle formulation (cationic). Coronary angiography and IVUS follow-up were performed 28 days after ISR treatment. There was one episode of acute coronary occlusion with the cationic formulation. Late area loss was similar in all groups at 28 days according to IVUS. However, luminal volume loss (control = 20.7%, anionic 1 = 4.0%, anionic 2 = 6.7%, cationic = 9.6%; P = 0.01) and neointimal volume gain (control = 68.7%, anionic 1 = 17.4%, anionic 2 = 29.5%, cationic = 31.2%; P = 0.019) were significantly reduced in all treatment groups, especially in anionic 1. PTCA-NC followed by local infusion of sirolimus nanoparticles was safe and efficacious to reduce neointima in this model, and this strategy may be a promising treatment for BMS ISR. Further studies are required to validate this method in humans. Copyright © 2012 Wiley Periodicals, Inc.

  13. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis

    NARCIS (Netherlands)

    Jaguszewski, Milosz; Aloysius, Romila; Wang, Wei; Bezerra, Hiram G.; Hill, Jonathan; de Winter, Robbert J.; Karjalainen, Pasi P.; Verheye, Stefan; Wijns, William; Lüscher, Thomas F.; Joner, Michael; Costa, Marco; Landmesser, Ulf

    2017-01-01

    The aim of the present study was to evaluate vascular healing of the bioengineered COMBO Dual Therapy Stent compared with a cobalt-chromium (CoCr) everolimus-eluting stent (EES) as assessed by optical coherence tomography in patients with acute coronary syndromes. CD34+ cells promote endothelial

  14. Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials

    DEFF Research Database (Denmark)

    Tanimoto, Shuzou; Serruys, Patrick W; Thuesen, Leif

    2007-01-01

    OBJECTIVES: This study sought to evaluate and compare in vivo acute stent recoil of a novel bioabsorbable stent and a metallic stent. BACKGROUND: The bioabsorbable everolimus-eluting coronary stent (BVS) is composed of a poly-L-lactic acid backbone, coated with a bioabsorbable polymer containing...... the antiproliferative drug, everolimus, and expected to be totally metabolized and absorbed in the human body. Because the BVS is made from polymer, it may have more acute recoil than metallic stents in vivo. METHODS: A total of 54 patients, who underwent elective stent implantation for single de novo native coronary...... artery lesions, were enrolled: 27 patients treated with the BVS and 27 patients treated with the everolimus-eluting cobalt chromium stent (EES). Acute absolute recoil, assessed by quantitative coronary angiography, was defined as the difference between mean diameter of the last inflated balloon...

  15. From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI

    NARCIS (Netherlands)

    Tenekecioglu, Erhan; Bourantas, Christos; Abdelghani, Mohammad; Zeng, Yaping; Silva, Rafael Cavalcante; Tateishi, Hiroki; Sotomi, Yohei; Onuma, Yoshinobu; Yılmaz, Mustafa; Serruys, Patrick W.

    2016-01-01

    Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir

  16. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Coronary Stents in Diabetic Patients: State of the Knowledge.

    Science.gov (United States)

    Codner, Pablo; Gurm, Hitinder Singh; Motivala, Apurva

    2017-04-01

    This review article aims to summarize the findings of the most relevant research that compared the use of paclitaxel vs. "limus" based drug eluting stent (DES) in diabetic patients and to define the current state of knowledge with new stent technologies in this patient population. Since drug eluting stents (DES) were introduced, it has been of great interest to establish whether paclitaxel or sirolimus eluting stents have the same safety and efficacy features for patients with coronary artery disease. The answer to this question is particularly relevant for diabetic patients. Several randomized trials, registry-based studies, and meta-analyses have assessed the performance of these different DES in diabetic patients. The most recently published data favors limus over paclitaxel DES in diabetic patients, but most of these studies compared first vs. second generation DES with the inherent caveats of comparing different platforms, alloys, and drug delivery vehicles. In this literature review, we found that there is robust evidence favoring the use of DES over bare metal stents in diabetic patients with coronary artery disease. We also found that the current state of knowledge is that the everolimus eluting stents have better safety and efficacy than paclitaxel eluting stents in diabetic patients and hence should be the preferred choice. New revascularization strategies including bio-absorbable scaffolds, polymer free stents, and bio-degradable polymers are being studied in diabetic patients with encouraging results.

  18. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    Science.gov (United States)

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. The effect of stent coating on stent deliverability: direct randomised comparison of drug eluting and bare metal stents using the same stent platform.

    Science.gov (United States)

    Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur

    2012-01-01

    There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect

  20. Long-term prognostic value of risk scores after drug-eluting stent implantation for unprotected left main coronary artery: A pooled analysis of the ISAR-LEFT-MAIN and ISAR-LEFT-MAIN 2 randomized clinical trials.

    Science.gov (United States)

    Xhepa, Erion; Tada, Tomohisa; Kufner, Sebastian; Ndrepepa, Gjin; Byrne, Robert A; Kreutzer, Johanna; Ibrahim, Tareq; Tiroch, Klaus; Valgimigli, Marco; Tölg, Ralf; Cassese, Salvatore; Fusaro, Massimiliano; Schunkert, Heribert; Laugwitz, Karl L; Mehilli, Julinda; Kastrati, Adnan

    2017-01-01

    To evaluate the long-term prognostic value of risk scores in the setting of drug-eluting stent (DES) implantation for uLMCA. Data on the prognostic value of novel risk scores developed to select the most appropriate revascularization strategy in patients undergoing DES implantation for uLMCA disease are relatively limited. The study represents a patient-level pooled analysis of the ISAR-LEFT-MAIN (607 patients randomized to paclitaxel-eluting or sirolimus-eluting stents) and the ISAR-LEFT-MAIN-2 (650 patients randomized to everolimus-eluting or zotarolimus-eluting stents) randomized trials. The Syntax Score (SxScore) as well the Syntax Score II (SS-II), the EuroSCORE and the Global Risk Classification (GRC) were calculated. The primary outcome was all-cause mortality. At a mean follow-up of 3 years there were 160 deaths (12.7%). The death-incidence was significantly higher in the upper tertiles than in the intermediate or lower ones for all risk scores (log-rank test P risk scores were able to stratify the mortality risk at long-term follow-up. EuroSCORE was the only risk score that significantly improved the discriminatory power of a multivariable model to predict long-term mortality. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Progress in the study of drug-eluting intra-stent thrombosis

    International Nuclear Information System (INIS)

    Guo Zhifu; Zheng Xing; Qin Yongwen

    2007-01-01

    Durg-eluting stent has been regarded as the milestone in the history of PCI for their efficiency in the prevention of coronary arterial restenosis after percutaneous coronary intervention. But unfortunately intra-stent thrombosis continues to be a serious complication of contemporary DES use. The incidence of drug-eluting stents thrombosis is at least not lower than that of bare metal stents at present. The clinical consequences of stent thrombosis are frequently catastrophic, including death in 40% to 50% of the cases or major myocardial infarction in 60% to 70%. Premature discontinuation of standard antiplatelet therapy is by far the most important predictor of stent thrombosis with DES and other predictors included renal failure, diabetes, bifurcation lesions, multiple lesions or multivessel disease, long stents, female, advanced age, stent underexpansion and residual stenosis etc. The delayed endothelialization may be the underling mechanism of DES thrombosis. (authors)

  2. Clinical outcomes in low risk coronary artery disease patients treated with different limus-based drug-eluting stents--a nationwide retrospective cohort study using insurance claims database.

    Directory of Open Access Journals (Sweden)

    Chao-Lun Lai

    Full Text Available The clinical outcomes of different limus-based drug-eluting stents (DES in a real-world setting have not been well defined. The aim of this study was to investigate the clinical outcomes of three different limus-based DES, namely sirolimus-eluting stent (SES, Endeavor zotarolimus-eluting stent (E-ZES and everolimus-eluting stent (EES, using a national insurance claims database. We identified all patients who received implantation of single SES, E-ZES or EES between January 1, 2007 and December 31, 2009 from the National Health Insurance claims database, Taiwan. Follow-up was through December 31, 2011 for all selected clinical outcomes. The primary end-point was all-cause mortality. Secondary end-points included acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. Cox regression model adjusting for baseline characteristics was used to compare the relative risks of different outcomes among the three different limus-based DES. Totally, 6584 patients were evaluated (n=2142 for SES, n=3445 for E-ZES, and n=997 for EES. After adjusting for baseline characteristics, we found no statistically significant difference in the risk of all-cause mortality in three DES groups (adjusted hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 0.94-1.38, p=0.20 in E-ZES group compared with SES group; adjusted HR: 0.77, 95% CI: 0.54-1.10, p=0.15 in EES group compared with SES group. Similarly, we found no difference in the three stent groups in risks of acute coronary events, heart failure needing hospitalization, and cerebrovascular disease. In conclusion, we observed no difference in all-cause mortality, acute coronary events, heart failure needing hospitalization, and cerebrovascular disease in patients treated with SES, E-ZES, and EES in a real-world population-based setting in Taiwan.

  3. Comparison of a Simple Angiographic Approach With a Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery Score-Based Approach for Left Main Coronary Artery Stenting: A Pooled Analysis of Serial PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery Versus Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease) Studies.

    Science.gov (United States)

    Lee, Pil Hyung; Lee, Jong-Young; Lee, Cheol Whan; Kim, Seon-Ok; Ahn, Jung-Min; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Park, Seung-Jung

    2018-01-01

    The applicability of Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery scores to left main coronary artery disease (CAD) has been questioned. A simplified alternative is needed for guiding decision making. We evaluated the prognostic value of a simplified angiographic classification in comparison with a Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score-based approach for patients with left main CAD undergoing drug-eluting stent implantation. The proposed approach classified left main CAD as either extensive (n=819), defined as left main bifurcation lesions with an involvement of ostial left circumflex artery or as any left main lesion plus multivessel CAD, or limited (n=453), defined as ostial/midshaft lesions or left main bifurcation lesions without an involvement of ostium of left circumflex artery, alone or plus 1-vessel disease. The databases from 4 prospective Premier of Randomized Comparison of Bypass Surgery versus Angioplasty Using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease studies were pooled, and the primary outcome was a major adverse cardiac event, defined as death, myocardial infarction, or repeat revascularization. During follow-up (median 38 months; interquartile range, 36-61 months), the risk for major adverse cardiac event was significantly higher with extensive than with limited left main CAD (adjusted hazard ratio, 2.13; 95% confidence interval, 1.54-2.94; P Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score tertiles did not effectively stratify these 2 outcome measures. Compared with Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery scores, the simpler angiographic approach provided better discrimination for future cardiovascular events in patients with left main CAD undergoing drug-eluting stent implantation. © 2018 American Heart Association, Inc.

  4. Clopidogrel discontinuation within the first year after coronary drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Thim, Troels; Johansen, Martin Berg; Chisholm, Gro Egholm

    2014-01-01

    BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug-eluting ......BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug......-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e., cardiac death, myocardial infarction, or stent thrombosis) from medical databases. RESULTS: Discontinuation of clopidogrel within the first 3 months after...... stent implantation was associated with a significantly increased rate of MACE at 1-year follow-up (hazard ratio (HR) 2.06; 95% confidence interval (CI): 1.08-3.93). Discontinuation 3-6 months (HR 1.29; 95% CI: 0.70-2.41) and 6-12 months (HR 1.29; 95% CI: 0.54-3.07) after stent implantation were...

  5. First-Generation Versus Second-Generation Drug-Eluting Stents in Coronary Chronic Total Occlusions: Two-Year Results of a Multicenter Registry.

    Directory of Open Access Journals (Sweden)

    Jong-Hwa Ahn

    Full Text Available Limited data are available regarding the long-term clinical outcomes of second-generation drug-eluting stents (DES versus first-generation DES in patients with coronary chronic total occlusion (CTO who undergo percutaneous coronary intervention (PCI. The aim of this study was to compare the clinical outcomes of second-generation DES with those of first-generation DES for the treatment of CTO.Between March 2003 and February 2012, 1,006 consecutive patients with CTO who underwent successful PCI using either first-generation DES (n = 557 or second-generation DES (n = 449 were enrolled in a multicenter, observational registry. Propensity-score matching was also performed. The primary outcome was cardiac death over a 2-year follow-up period. No significant differences were observed between the two groups regarding the incidence of cardiac death (first-generation DES versus second-generation DES; 2.5% vs 2.0%; hazard ratio [HR]: 0.86; 95% confidence interval [CI]: 0.37 to 1.98; p = 0.72 or major adverse cardiac events (MACE, 11.8% vs 11.4%; HR: 1.00; 95% CI: 0.67 to 1.50; p = 0.99. After propensity score matching, the incidences of cardiac death (HR: 0.86; 95% CI: 0.35 to 2.06; p = 0.86 and MACE (HR: 0.93; 95% CI: 0.63 to 1.37; p = 0.71 were still similar in both groups. Furthermore, no significant differences were observed between sirolimus-eluting, paclitaxel-eluting, zotarolimus-eluting, and everolimus-eluting stents regarding the incidence of cardiac death or MACE.This study shows that the efficacy of second-generation DES is comparable to that of first-generation DES for treatment of CTO over 2 years of follow-up.

  6. Endothelial cell repopulation after stenting determines in-stent neointima formation: effects of bare-metal vs. drug-eluting stents and genetic endothelial cell modification.

    Science.gov (United States)

    Douglas, Gillian; Van Kampen, Erik; Hale, Ashley B; McNeill, Eileen; Patel, Jyoti; Crabtree, Mark J; Ali, Ziad; Hoerr, Robert A; Alp, Nicholas J; Channon, Keith M

    2013-11-01

    Understanding endothelial cell repopulation post-stenting and how this modulates in-stent restenosis is critical to improving arterial healing post-stenting. We used a novel murine stent model to investigate endothelial cell repopulation post-stenting, comparing the response of drug-eluting stents with a primary genetic modification to improve endothelial cell function. Endothelial cell repopulation was assessed en face in stented arteries in ApoE(-/-) mice with endothelial-specific LacZ expression. Stent deployment resulted in near-complete denudation of endothelium, but was followed by endothelial cell repopulation, by cells originating from both bone marrow-derived endothelial progenitor cells and from the adjacent vasculature. Paclitaxel-eluting stents reduced neointima formation (0.423 ± 0.065 vs. 0.240 ± 0.040 mm(2), P = 0.038), but decreased endothelial cell repopulation (238 ± 17 vs. 154 ± 22 nuclei/mm(2), P = 0.018), despite complete strut coverage. To test the effects of selectively improving endothelial cell function, we used transgenic mice with endothelial-specific overexpression of GTP-cyclohydrolase 1 (GCH-Tg) as a model of enhanced endothelial cell function and increased NO production. GCH-Tg ApoE(-/-) mice had less neointima formation compared with ApoE(-/-) littermates (0.52 ± 0.08 vs. 0.26 ± 0.09 mm(2), P = 0.039). In contrast to paclitaxel-eluting stents, reduced neointima formation in GCH-Tg mice was accompanied by increased endothelial cell coverage (156 ± 17 vs. 209 ± 23 nuclei/mm(2), P = 0.043). Drug-eluting stents reduce not only neointima formation but also endothelial cell repopulation, independent of strut coverage. In contrast, selective targeting of endothelial cell function is sufficient to improve endothelial cell repopulation and reduce neointima formation. Targeting endothelial cell function is a rational therapeutic strategy to improve vascular healing and decrease neointima formation after stenting.

  7. Percutaneous coronary intervention with second-generation paclitaxel-eluting stents versus everolimus-eluting stents in United States contemporary practice (REWARDS TLX Trial).

    Science.gov (United States)

    Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca

    2012-10-15

    Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Ostojic, Miodrag

    2012-01-01

    The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI).......The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI)....

  9. Incidence of definite stent thrombosis or in-stent restenosis after drug-eluting stent implantation for treatment of coronary in-stent restenosis. From western denmark heart registry

    DEFF Research Database (Denmark)

    Jensen, Jesper; Jensen, Lisette Okkels; Terkelsen, Christian Juhl

    2012-01-01

    There are limited data on the optimal management of in-stent restenosis after percutaneous coronary intervention (PCI) with bare metal stent (BMS) or drug-eluting stent (DES) implantations. We assessed the clinical presentation, the incidence, and prognosis of definite stent thrombosis...

  10. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2012-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  11. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  12. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    Science.gov (United States)

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  13. Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, Denise Oliveira, E-mail: dennizmo@yahoo.com.br; Gomes, Vitor Osório; Lasevitch, Ricardo; Smidt, Luis; Azeredo, Marco Aurélio; Ledur, Priscila; Bodanese, Rodrigo; Sinnott, Leonardo; Moriguchi, Emílio; Caramori, Paulo [Hospital São Lucas PUC, Porto Alegre, RS (Brazil)

    2014-09-15

    Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. To evaluate the efficacy and safety of drug-eluting stents in the real world. We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the 'real world' may benefit from drug-eluting stenting with excellent, long-term results.

  14. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis.

    Science.gov (United States)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe

    2014-11-04

    To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; Pstents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.

  15. Outcome of Sirolimus-Eluting Versus Zotarolimus-Eluting Coronary Stent Implantation in Patients With and Without Diabetes Mellitus (a SORT OUT III Substudy)

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette O; Tilsted, Hans-Henrik

    2011-01-01

    Diabetes is associated with an increased risk of major adverse cardiac events after percutaneous coronary intervention. We compared clinical outcomes in patients with and without diabetes mellitus treated with the second-generation Endeavor zotarolimus-eluting stent (ZES) or the first...... cardiac events defined as a composite of cardiac death, myocardial infarction, or target vessel revascularization. Secondary end points included these individual end points plus all-cause mortality and target lesion revascularization. In diabetic patients, use of ZES compared to SES was associated.......90 to 13.1), and target lesion revascularization (12.4% vs 1.2%, hazard ratio 11.0, 95% confidence interval 2.59 to 47.1). In patients without diabetes differences in absolute risk decrease were smaller but similarly favored SES. In conclusion, implantation of ZESs compared to SESs is associated...

  16. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    Science.gov (United States)

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http

  17. TCT-584 Nine Month Imaging and Twelve Month Clinical Results from the DESSOLVE II Randomized Trial of the MiStent® SES with Absorbable Polymer

    OpenAIRE

    Wijns, William; Vrolix, Mathias; Verheye, Stefan; Schoors, Danny; Slagboom, Ton; Gosselink, Marcel; Benit, Edouard; Desmet, Walter; Chowdhary, Saquib; Lansky, Alexandra; Bezerra, Hiram; Fitzgerald, Peter; Kandzari, David; Ormiston, John

    2012-01-01

    Background : The MiStent SES (Micell Technologies, Durham, NC) is an investigational drug-eluting stent (DES) developed to adress unfavorable late-term outcomes such as stent thrombosis. These events are hypothesized to be associated in part with durable polymers of current DES. The MiStent SES uses a unique combination of components, a crystalline formulation of sirolimus and a fully absorbable polymer on a thinstrut, cobalt chromium stent platform. The polymer coating is eliminated from the...

  18. Drug-eluting versus bare-metal stents in large coronary arteries

    DEFF Research Database (Denmark)

    Kaiser, Christoph; Galatius, Soeren; Erne, Paul

    2010-01-01

    Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether...

  19. Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).

    Science.gov (United States)

    Lee, Joo Myung; Park, Kyung Woo; Han, Jung-Kyu; Yang, Han-Mo; Kang, Hyun-Jae; Koo, Bon-Kwon; Bae, Jang-Whan; Woo, Sung-Il; Park, Jin Sik; Jin, Dong-Kyu; Jeon, Dong Woon; Oh, Seok Kyu; Park, Jong-Seon; Kim, Doo-Il; Hyon, Min Su; Jeon, Hui-Kyung; Lim, Do-Sun; Kim, Myeong-Gon; Rha, Seung-Woon; Her, Sung-Ho; Hwang, Jin-Yong; Kim, Sanghyun; Choi, Young Jin; Kang, Jin Ho; Moon, Keon-Woong; Jang, Yangsoo; Kim, Hyo-Soo

    2014-11-01

    Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p stents showed comparable safety and efficacy at 3-year follow-up in this robust real-world registry with unrestricted use of EES and

  20. Drug-eluting stents versus bare-metal stents for acute coronary syndrome

    DEFF Research Database (Denmark)

    Feinberg, Joshua; Nielsen, Emil Eik; Greenhalgh, Janette

    2017-01-01

    -EXPANDED, and BIOSIS from their inception to January 2017. We also searched two clinical trials registers, the European Medicines Agency and the US Food and Drug Administration databases, and pharmaceutical company websites. In addition, we searched the reference lists of review articles and relevant trials. SELECTION...... CRITERIA: Randomised clinical trials assessing the effects of drug-eluting stents versus bare-metal stents for acute coronary syndrome. We included trials irrespective of publication type, status, date, or language. DATA COLLECTION AND ANALYSIS: We followed our published protocol and the methodological...

  1. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    Science.gov (United States)

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  2. Toxic vessel reaction to an absorbable polymer-based paclitaxel-eluting stent in pig coronary arteries.

    Science.gov (United States)

    Jabara, Refat; Chronos, Nicolas; Tondato, Fernando; Conway, Damian; Molema, Warner; Park, Kenneth; Mabin, Tom; King, Spencer; Robinson, Keith

    2006-08-01

    The goal of this study was to evaluate a new drug-eluting stent (DES) comprising a bioabsorbable polymer eluting a moderate dose of paclitaxel in a clinically relevant animal model. Although DES limit restenosis, adverse vascular pathologies and toxicities continue to be of major concern. Optimization of DES components, especially completely absorbable polymers, may reduce these toxicities. Bare-metal (BM), absorbable polymer coating only (POLY), and polymer-based paclitaxel-eluting (PACL) stents were implanted in porcine coronary arteries using intravascular ultrasound (IVUS) to optimize stent apposition. The dose density of paclitaxel was 0.30-0.35 mcg/mm2, with in vitro elution studies demonstrating a gradual elution over 6-8 weeks. The animals were terminated at 1 week, 1 month and 3 months. Histopathologic and histomorphometric analyses were perform. The arteries with PACL showed extensive smooth muscle cell necrosis at 1 week and poor apposition of stent struts at 1 month (malapposition measured as gap width between strut and internal elastic lamina), with greater gap width compared to the BM and POLY groups (0.22 mm +/- 0.02 vs. 0.03 mm +/- 0.02 and 0.02 mm +/- 0.01, respectively; p stent malapposition and late neointimal thickening. Since the therapeutic window for paclitaxel may be narrower than currently inferred, thorough preclinical testing coupled with the polymer development process for stents eluting paclitaxel is needed.

  3. Similar five-year outcome with paclitaxel- and sirolimus-eluting coronary stents

    DEFF Research Database (Denmark)

    Bligaard, Niels; Thuesen, Leif; Saunamäki, Kari

    2014-01-01

    patients with ST-segment elevation myocardial infarction (STEMI), non-STEMI, stable or unstable angina pectoris were randomized to receive Cypher™ (n = 1.065) or Taxus™ (n = 1.033) stents and were followed for 5 years. RESULTS: The primary end-point; the composite of cardiac death, myocardial infarction...... and target vessel revascularization (major adverse cardiac event, MACE), occurred in 467 patients (22.3%); Cypher™ n = 222 (20.8%), Taxus™ n = 245 (23.7%), ns. Definite and probable stent thrombosis occurred in 107 patients (5.1%); Cypher™ n = 51 (4.8%), Taxus™ n = 56 (5.4%), ns. No statistically significant...

  4. Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

    DEFF Research Database (Denmark)

    Gutiérrez-Chico, Juan Luis; van Geuns, Robert Jan; Regar, Evelyn

    2011-01-01

    To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an 'all-comers' population of patients, in order to clarify the mechanism of eventual...

  5. Effect of Post-Dilatation Following Primary PCI With Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stent Implantation

    DEFF Research Database (Denmark)

    Yamaji, Kyohei; Brugaletta, Salvatore; Sabaté, Manel

    2017-01-01

    OBJECTIVES: This study sought to investigate the effect of post-dilatation on angiographic and intracoronary imaging parameters in the setting of primary percutaneous coronary intervention comparing the everolimus-eluting bioresorbable scaffold (BRS) with the everolimus-eluting metallic stent (EE...

  6. Patient-rated health status predicts prognosis following percutaneous coronary intervention with drug-eluting stenting

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Versteeg, Henneke; Denollet, Johan

    2011-01-01

    In patients treated with percutaneous coronary intervention (PCI) with the paclitaxel-eluting stent, we examined whether patient-rated health status predicts adverse clinical events.......In patients treated with percutaneous coronary intervention (PCI) with the paclitaxel-eluting stent, we examined whether patient-rated health status predicts adverse clinical events....

  7. Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Kaltoft, Anne

    2007-01-01

    OBJECTIVES: The aim of the study was to examine outcomes subsequent to implantation of drug-eluting stents (DES) and bare-metal stents (BMS). BACKGROUND: Use of DES might be associated with increased risk of stent thrombosis (ST), myocardial infarction (MI), and death. METHODS: From January 2002...... through June 2005, data from all percutaneous coronary interventions in western Denmark were prospectively recorded in the Western Denmark Heart Registry; 12,395 consecutive patients (17,152 lesions) treated with stent implantation were followed for 15 months. Data on death and MI were ascertained from...... within 15 months after implantation of DES seems unlikely to outweigh the benefit of these stents. Udgivelsesdato: 2007-Jul-31...

  8. Comparison of the sirolimus-eluting versus paclitaxel-eluting coronary stent in patients with diabetes mellitus: the diabetes and drug-eluting stent (DiabeDES) randomized angiography trial

    DEFF Research Database (Denmark)

    Maeng, Michael; Jensen, Lisette Okkels; Galloe, Anders Michael

    2008-01-01

    group (0.23 +/- 0.54 vs 0.44 +/- 0.52 mm, p = 0.025). Angiographic in-segment restenosis at 8-month follow-up, a secondary end point, was present in 16 patients (Cypher, n = 6; Taxus, n = 10; p = 0.24). Target lesion revascularization was performed in 5 patients (6.5%) and 9 patients (11.......8%) in the Cypher and Taxus groups, respectively (p = 0.25). Definite stent thrombosis was observed in 2 patients (in the Taxus group), no patients had probable stent thrombosis, and 1 patient in each group had possible stent thrombosis. Major adverse cardiac events (cardiac death, myocardial infarction, definite...

  9. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    International Nuclear Information System (INIS)

    Han, Dong-Wook; Lee, Jun Jae; Jung, Duk-Young; Park, Jong-Chul; Hyon, Suong-Hyu

    2009-01-01

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-ε-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  10. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong-Wook [Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 609-735 (Korea, Republic of); Lee, Jun Jae [Division of Advanced Fibro-Science, Kyoto Institute of Technology, Kyoto 606-8585 (Japan); Jung, Duk-Young [Senior Products Industrial Center, Busan Techno-Park, Busan-617-030 (Korea, Republic of); Park, Jong-Chul [Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 120-752 (Korea, Republic of); Hyon, Suong-Hyu, E-mail: nanohan@pusan.ac.k, E-mail: biogen@frontier.kyoto-u.ac.j [Department of Medical Simulation Engineering, Institute for Frontier Medical Sciences, Kyoto University, Kyoto 606-8507 (Japan)

    2009-08-15

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-epsilon-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  11. Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

    Science.gov (United States)

    Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro

    2011-06-01

    Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; Ppolymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.

  12. Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Sabaté, Manel; Windecker, Stephan; Iñiguez, Andres

    2015-01-01

    AIMS: Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential...... to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES...... was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition...

  13. Clinical outcomes with drug-eluting and bare-metal stents in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Biondi-Zoccai, Giuseppe; Della Riva, Diego

    2013-01-01

    The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis.......The authors investigated the relative safety and efficacy of different drug-eluting stents (DES) and bare metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) using a network meta-analysis....

  14. Enhanced drug delivery capabilities from stents coated with absorbable polymer and crystalline drug.

    Science.gov (United States)

    Carlyle, Wenda C; McClain, James B; Tzafriri, Abraham R; Bailey, Lynn; Zani, Brett G; Markham, Peter M; Stanley, James R L; Edelman, Elazer R

    2012-09-28

    Current drug eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug delivery. A novel, absorbable-coating sirolimus-eluting stent (AC-SES) was evaluated for its capacity to deliver drug more evenly within the intimal area rather than concentrating drug around the stent struts and for its ability to match coating erosion with drug release. The coating consisted of absorbable poly-lactide-co-glycolic acid (PLGA) and crystalline sirolimus deposited by a dry-powder electrostatic process. The AC-SES demonstrated enhanced drug stability under simulated use conditions and consistent drug delivery balanced with coating erosion in a porcine coronary implant model. The initial drug burst was eliminated and drug release was sustained after implantation. The coating was absorbed within 90 days. Following implantation into porcine coronary arteries the AC-SES coating is distributed in the surrounding intimal tissue over the course of several weeks. Computational modeling of drug delivery characteristics demonstrates how distributed coating optimizes the load of drug immediately around each stent strut and extends drug delivery between stent struts. The result was a highly efficient arterial uptake of drug with superior performance to a clinical bare metal stent (BMS). Neointimal thickness (0.17±0.07 mm vs. 0.28±0.11 mm) and area percent stenosis (22±9% vs. 35±12%) were significantly reduced (pstent implantation in an overlap configuration in porcine coronary arteries. Inflammation was significantly reduced in the AC-SES compared to the BMS at both 30 and 90 days after implantation. Biocompatible, rapidly absorbable stent coatings enable the matching of drug release with coating erosion and provide for the controlled migration of coating material into tissue to reduce vicissitudes in drug tissue levels, optimizing efficacy and reducing potential toxicity. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Clinical results with the Resolute zotarolimus-eluting stent in total coronary occlusions

    DEFF Research Database (Denmark)

    Kelbæk, Henning; Holmvang, Lene; Richardt, Gert

    2015-01-01

    Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and resu......Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods...... lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite...... or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally...

  16. Randomized comparison between intracoronary β-radiation brachytherapy and implantation of paclitaxel-eluting stents for the treatment of diffuse in-stent restenosis

    International Nuclear Information System (INIS)

    Schukro, Christoph; Syeda, Bonni; Kirisits, Christian; Schmid, Rainer; Pichler, Philipp; Pokrajac, Boris; Lang, Irene; Poetter, Richard; Glogar, Dietmar

    2007-01-01

    Background and purpose: Intracoronary brachytherapy was the primary therapeutic option for the treatment of in-stent restenosis (ISR) during the last years. Especially for the treatment of diffuse ISR (lesions >10 mm), β-source brachytherapy was significantly superior to singular balloon angioplasty. Despite lacking clinical database, the implantation of drug eluting stents recently became a common procedure for the treatment of ISR. This randomized trial aimed to compare the efficacy of β-brachytherapy with β-radioisotopes 90 Sr/ 90 Y and paclitaxel-eluting stent implantation for the treatment of diffuse ISR. Material and methods: Thirty-seven patients with diffuse ISR were randomly assigned to β-brachytherapy after balloon angioplasty (Beta-Cath TM in 17 patients) or paclitaxel-eluting stent implantation (Taxus-Express2 TM in 20 patients). Six-month clinical follow-up was obtained for all patients, while angiographic follow-up was available for 30 patients. Results: Binary ISR (restenosis >50%) within target segment was observed in three patients treated with Beta-Cath TM , of which one needed target segment revascularisation for recurrent ISR, whereas no significant restenosis occurred in the patients treated with Taxus-Express2 TM (P = 0.037). No further major adverse cardiac (target segment revascularisation, myocardial infarction, death) was found in either group (P = NS). Stent implantation was the more time-saving (31 ± 11 min versus 60 ± 23 min, P TM arm, we found no difference in clinical outcome after implantation of paclitaxel-eluting stents for the treatment of diffuse ISR when compared to β-brachytherapy

  17. Drug-eluting stents: from bench-top to clinical research

    NARCIS (Netherlands)

    Basalus, Mounir Welson Zakhary

    2013-01-01

    The development of drug-eluting stents (DES) has improved the invasive treatment of obstructive coronary artery disease by reducing both, restenosis rate and need for reinterventions. This success resulted in a widespread utilization of DES in clinical practice and entailed many clinical research

  18. The OCT-ORION Study: A Randomized Optical Coherence Tomography Study Comparing Resolute Integrity to Biomatrix Drug-Eluting Stent on the Degree of Early Stent Healing and Late Lumen Loss.

    Science.gov (United States)

    Lee, Stephen W L; Tam, Frankie C C; Lam, Simon C C; Kong, Shun-Ling; Shea, Catherine P; Chan, Kelvin K W; Wong, Michael K L; Chan, Michael P H; Wong, Anthony Y T; Yung, Arthur S Y; Lam, Yui-Ming; Zhang, Lei-Wei; Wu, Karl K Y; Mintz, Gary S; Maehara, Akiko

    2018-04-01

    Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer. Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months ( P <0.001) and less variance of percent coverage at 9 months, 99.7% (interquartile range, 99.1-100) versus 99.6% (interquartile range, 96.8-99.9; difference, 0.10; 95% confidence interval, 0.00-1.05; P <0.001). No significant difference was observed in major adverse cardiac events or angiographic end points. Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small

  19. The Role Of Inflammation In Stent Restenosis More Than 1 Year Afetr Drug Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Hasan Shemirani

    2011-09-01

    Full Text Available Background: In stent restenosis (ISR following endovascular interventions is the main limitation of their long-term success. Despite advances have been made during recent years to decrease restenosis, it remains a challenging clinical problem.The aim of this study was to evaluate the relationship between angiographic coronary in stent restenosis, inflammation after successful stent implantation. Methods: This study included 78 patients, 35year old and higher who underwent coronary angiography more than 1 year after drug-eluting stent (DES implantation because of symptoms suggestive ischemia. Patients were divided into ISR group (case and patent stent group (control according to angiography results. For all patients blood lipids and high sensitivity C-Reactive Protein (hsCRP were measured simultaneously. Results: Age, sex, hypertension, current smoking, and lipid profile other than High Density Lipoprotein (HDL-C of patients in the case and control groups were similar .However, HDL-C < 40mg/L was more prevalent with ISR (66.7% vs. 30.8%, p=0.002. The hsCRP level was 2.98±2.06 mg/L in the case group and 2.50±1.80 mg/L in the control group. There were no significant differences in mean hsCRP concentration between the two groups (p=0.14, however mean hsCRP level was significantly higher in men of case group than control group (3.35mg/L vs. 2.21mg/L, p<0.05. Conclusion: This study demonstrates that in men but not in women inflammation may be a predictor of in stent restenosis more than 1 year after drug eluting stent implantation. Also, high-density lipoprotein (HDL probably has protective effect against stent restenosis.

  20. Estudo Pré-Clínico de Stent com Polímero Biodegradável e Liberação Abluminal de Sirolimus

    Directory of Open Access Journals (Sweden)

    Celso Kiyochi Takimura

    2014-06-01

    Full Text Available Fundamento: Stents recobertos com polímeros bioabsorvíveis e fármacos apenas na face abluminal podem ser mais seguros que stents farmacológicos com polímeros permanentes. Objetivo: Relatar os resultados experimentais com o stent Inspiron(r, um stent recoberto com polímero bioabsorvível e com liberação de sirolimus apenas da face abluminal, recentemente aprovado para uso clínico. Métodos: Foram implantados 45 stents nas artérias coronárias de 15 porcos e, no 28° dia pós-implante, foram obtidos os resultados angiográficos, de ultrassonografia intracoronária e de histomorfologia. Cinco grupos foram avaliados: Grupo I (nove stents sem recobrimento; Grupo II (nove stents com polímero bioabsorvível nas faces luminal e abluminal; Grupo III (oito stents com polímero bioabsorvível na face abluminal; Grupo IV (nove stents com polímero bioabsorvível e sirolimus nas faces luminal e abluminal; e Grupo V (dez stents com polímero bioabsorvível e sirolimus na face abluminal exclusivamente. Resultados: Observamos, para os Grupos I, II, III, IV e V respectivamente: porcentual de estenose de 29 ± 20; 36 ± 14; 33 ± 19; 22 ± 13 e 26 ± 15 (p = 0,443; perda luminal tardia (em mm de 1,02 ± 0,60; 1,24 ± 0,48; 1,11 ± 0,54; 0,72 ± 0,44 e 0,78 ± 0,39 (p = 0,253; área neointimal (em mm2 de 2,60 ± 1,99; 2,74 ± 1,51; 2,74 ± 1,30; 1,30 ± 1,14 e 0,97 ± 0,84 (p = 0,001; Grupos IV e V versus Grupos I, II e III e porcentual de área neointimal de 35 ± 25; 38 ± 18; 39 ± 19; 19 ± 18 e 15 ± 12 (p = 0,001; Grupo IV e V versus Grupo I, II e III. Os escores de injúria e inflamação foram baixos e sem diferenças entre os grupos. Conclusão: O stent Inspiron(r foi seguro e inibiu significativamente a hiperplasia neointimal observada no 28° dia pós-implante em artérias coronárias porcinas.

  1. Magmaris: a new generation metallic sirolimus-eluting fully bioresorbable scaffold: present status and future perspectives

    OpenAIRE

    Rapetto, Claudio; Leoncini, Massimo

    2017-01-01

    Drug-eluting stents (DES) have reached a high safety and efficacy profile, becoming the best option for percutaneous coronary interventions (PCI) based revascularization. However, despite their optimal performance, a few concerns remain regarding their use, mainly due to permanent caging of the vessels and its consequences, first of all late stent thrombosis (ST). Bioresorbable scaffolds (BRS) aim to overcome these issues. The results achieved in randomized controlled trials (RCT) by the firs...

  2. Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Zaugg, Serge

    2016-01-01

    BACKGROUND: The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using optical coherence tomography, we investigated potential causes of this adverse event. METHODS AND RESULTS: Between August 2010 and Decemb...

  3. Functional Nanoarchitectures For Enhanced Drug Eluting Stents

    Science.gov (United States)

    Saleh, Yomna E.; Gepreel, Mohamed A.; Allam, Nageh K.

    2017-01-01

    Different strategies have been investigated to allow for optimum duration and conditions for endothelium healing through the enhancement of coronary stents. In this study, a nanoarchitectured system is proposed as a surface modification for drug eluting stents. Highly oriented nanotubes were vertically grown on the surface of a new Ni-free biocompatible Ti-based alloy, as a potential material for self-expandable stents. The fabricated nanotubes were self-grown from the potential stent substrate, which are also proposed to enhance endothelial proliferation while acting as drug reservoir to hinder Vascular Smooth Muscle Cells (VSMC) proliferation. Two morphologies were synthesized to investigate the effect of structure homogeneity on the intended application. The material was characterized by field-emission scanning electron microscope (FESEM), X-ray diffraction (XRD), Raman spectroscopy, energy dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). Nanoindentation technique was used to study the mechanical properties of the fabricated material. Cytotoxicity and proliferation studies were performed and compared for the two fabricated nanoarchitectures, versus smooth untextured samples, using in-vitro cultured endothelial cells. Finally, the drug loading capacity was experimentally studied and further supported by computational modeling of the release profile.

  4. Comparison of Acute Thrombogenicity for Magnesium versus Stainless Steel Stents in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David G; Joner, Michael; Harder, Claus; Zumstein, Philine; Finn, Aloke V; Kolodgie, Frank D; Virmani, Renu; Waksman, Ron

    2018-05-08

    Aims The aetiology for reduced thrombogenicity of the Magmaris resorbable magnesium scaffold (RMS) when compared with the Absorb bioresorbable vascular scaffold remains unclear. We therefore investigated whether the Magmaris RMS has platelet-repelling properties by comparing its acute thrombogenicity with an equivalent stainless steel stent in an arteriovenous shunt model. Methods and Results An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to Sylgard tubing containing the Magmaris RMS with sirolimus-eluting PLLA coating and an equivalent 316L stainless steel stent with sirolimus-eluting PLLA coating. Six shunts (2 shunt runs per pig) were run comparing the 2 scaffolds (n=9) in alternating order. Nested generalised linear mixed models were employed to compare variables between scaffold groups. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that the 316L equivalent stent had significantly greater platelet coverage of the total scaffold compared with Magmaris (5.8% vs. 2.8%, Rate ratio 2.21 [1.41, 3.47], p=0.012). Scanning electron microscopy demonstrated significantly greater thrombus deposition on the 316L equivalent stent as a percentage of the total scaffold compared with Magmaris (8.0% vs. 5.3%, p=0.009). Magmaris also had significantly less CD14 positive monocyte deposition and a trend toward less PM-1 positive neutrophil compared with the 316L equivalent stent. Conclusion Despite having identical scaffold characteristics regarding geometrical design, Magmaris had significantly less thrombogenicity and inflammatory cell deposition compared with the equivalent 316L stainless steel stent in a porcine arteriovenous shunt model. These data suggest resorbable magnesium scaffolds may have inherent properties that reduce adhesion of platelets and inflammatory cells.

  5. OrbusNeich fully absorbable coronary stent platform incorporating dual partitioned coatings.

    Science.gov (United States)

    Cottone, Robert J; Thatcher, G Lawrence; Parker, Sherry P; Hanks, Laurence; Kujawa, David A; Rowland, Stephen M; Costa, Marco; Schwartz, Robert S; Onuma, Yoshinobu

    2009-12-15

    The field of stent based tissue engineering continues to revolutionise modern medicine by designing novel materials to restore vascular tissue function. Accordingly, the following discussion examines a novel, absorbable, polymeric scaffold engineered in combination with dual therapeutic coating, enabling locally administered temporary scaffolding in the coronary arteries for long term vascular patency and repair. This coronary stent platform consists of an absorbable polymeric material stent structure that incorporates a dual partitioned coating, by means of pro-healing EPC (endothelial progenitor cell) capture technology allowing for rapid endothelial coverage, and an absorbable polymer matrix with sustained elution of sirolimus, a drug controlling neointimal proliferation. This paper provides a brief overview of the various innovations developed by OrbusNeich to create this fully absorbable coronary device platform.

  6. In Vivo and In Vitro Elution of Analgesics from Multilayered Poly(D,L-lactide-co-glycolide Nanofibers Incorporated Ureteral Stents

    Directory of Open Access Journals (Sweden)

    Yi-Chia Lin

    2018-01-01

    Full Text Available We develop novel analgesic-eluting nanofiber-incorporated ureteral stents that offer sustained release of lidocaine and ketorolac for local drug delivery. Lidocaine and poly(D,L-lactide-co-glycolide (PLGA were dissolved in hexafluoroisopropanol and were electrospun into nonwoven nanofibers onto the surface of ureteral stents. This was followed by electrospinning of another layer of PLGA nanofibers containing ketorolac. Electrospun drug-loaded nanofibers were then characterized using scanning electron microscopy, Fourier transform infrared spectroscopy, and water contact angle analysis. In addition, the elution behavior characteristics of the analgesics, both in vivo and in vitro, from the nanofiber-incorporated stents were evaluated. Experimental results indicate that the analgesic-eluting ureteral stents could liberate high strengths of analgesics in vitro and in vivo for at least 50 and 30 days, respectively. The analgesic-eluting nanofiber-incorporated ureteral stents are potentially applicable for alleviating the discomfort associated with stent implant.

  7. Second generation drug-eluting stents versus bare-metal stents for percutaneous coronary intervention of the proximal left anterior descending artery

    DEFF Research Database (Denmark)

    Mangione, Fernanda Marinho; Biering-Sørensen, Tor; Nochioka, Kotaro

    2017-01-01

    OBJECTIVES: To compare mid-term outcomes between patients undergoing proximal left anterior descending artery (LAD) percutaneous coronary intervention (PCI) with second generation drug-eluting stent (DES) or bare-metal stent (BMS). BACKGROUND: PCI with BMS and first-generation DES have shown to b...

  8. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention

    OpenAIRE

    Baschet, Louise; Bourguignon, Sandrine; Marque, S?bastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    Objective To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. Methods A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117?762 patient-years with 76 randomised trials. The main effectiveness criterion was major c...

  9. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II)

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Chevalier, Bernard; Sotomi, Yohei

    2016-01-01

    BACKGROUND: No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a re...

  10. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  11. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne Kjer

    2013-01-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention.......This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention....

  12. Improved two-year outcomes after drug-eluting versus bare-metal stent implantation in women and men with large coronary arteries

    DEFF Research Database (Denmark)

    Hansen, K W; Kaiser, C; Hvelplund, A

    2013-01-01

    To investigate the importance of vessel size on outcome differences by comparing the effects of drug-eluting stents (DES) versus bare-metal stents (BMS) in women and men with large coronary vessels.......To investigate the importance of vessel size on outcome differences by comparing the effects of drug-eluting stents (DES) versus bare-metal stents (BMS) in women and men with large coronary vessels....

  13. Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits.

    Directory of Open Access Journals (Sweden)

    Matthijs S Ruiter

    Full Text Available The introduction of drug-eluting stents (DES has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC, endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface.Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions.Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation.We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient.

  14. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.

    Science.gov (United States)

    Poerner, Tudor C; Otto, Sylvia; Gassdorf, Johannes; Nitsche, Kristina; Janiak, Florian; Scheller, Bruno; Goebel, Björn; Jung, Christian; Figulla, Hans R

    2014-12-01

    In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64±9.65% in BMS+DEB versus 4.93±9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7±7.8 versus 11.0±5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8±11.9 versus 16.9±10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5±13.8% versus 36.8±15.6%; P=0.409) was found. Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up. http://www.clinicaltrials.gov. Unique identifier: NCT01056744. © 2014 American Heart Association, Inc.

  15. Zotarolimus-eluting stent for the treatment of recurrent, severe carotid artery in-stent stenosis in the TARGET-CAS population.

    Science.gov (United States)

    Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr

    2012-06-01

    To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.

  16. EW-7197 eluting nano-fiber covered self-expandable metallic stent to prevent granulation tissue formation in a canine urethral model.

    Directory of Open Access Journals (Sweden)

    Kichang Han

    Full Text Available To evaluate an EW-7197-eluting nanofiber-covered stent (NFCS for suppressing granulation tissue formation after stent placement in a canine urethral model.All experiments were approved by the committee of animal research. A total of 12 NFCSs were placed in the proximal and distal urethras of six dogs. Dogs were divided into two groups with 3 dogs each. The control stent (CS group received NFCSs and the drug stent (DS group received EW-7197 (1000 μg-eluting NFCSs. All dogs were sacrificed 8 weeks after stent placement Histologic findings of the stented urethra were compared using the Mann-Whitney U test.Stent placement was technically successful in all dogs without procedure-related complications. On urethrographic analysis, the mean luminal diameter was significantly larger in the DS group than in the CS group at 4 and 8 weeks after stent placement (all p 0.05.The EW-7197-eluting NFCS is effective and safe for suppressing granulation tissue formation after stent placement in a canine urethral model.

  17. Absence of gender disparity in short-term clinical outcomes in patients with acute ST-segment elevation myocardial infarction undergoing sirolimus-eluting stent based primary coronary intervention: a report from Shanghai Acute Coronary Event (SACE) Registry.

    Science.gov (United States)

    Zhang, Qi; Qiu, Jian-Ping; Zhang, Rui-Yan; Li, Yi-Gang; He, Ben; Jin, Hui-Gen; Zhang, Jun-Feng; Wang, Xiao-Long; Jiang, Li; Liao, Min-Lei; Hu, Jian; Shen, Wei-Feng

    2010-04-05

    Randomized, controlled trials have demonstrated the superiority of sirolimus-eluting stent (SES) implantation during primary percutaneous coronary intervention (PCI), as opposed to bare-metal stents, in patients with ST-elevation myocardial infarction (STEMI). This study aimed to test the hypothesis that clinical benefits of SES treatment were independent of gender in this setting. A total of 2042 patients with STEMI undergoing SES-based primary PCI were prospectively enrolled into Shanghai Acute Coronary Event (SACE) registry (1574 men and 468 women). Baseline demographics, angiographic and PCI features, and in-hospital and 30-day major adverse cardiac events (MACE) were analyzed as a function of gender. Compared with men, women were older and more frequently had hypertension, diabetes, and hypercholesterolemia. Use of platelet glycoprotein IIb/IIIa receptor inhibitor (GPI, 65.5% vs. 62.2%, P = 0.10) and procedural success rate (95.0% vs. 94.2%, P = 0.52) were similar in both genders. In-hospital death and MACE occurred in 3.8% and 7.6%, and 4.5% and 8.1% in the male and female patients, respectively (all P > 0.05). At 30-day follow-up, survival (94.3% vs. 93.8%, P = 0.66) and MACE-free survival (90.2% vs. 89.3%, P = 0.52) did not significantly differ between men and women. After adjustment for differences in patient demographics, angiographic and procedural features, there were no significant difference in either in-hospital (OR = 0.77, 95%CI of 0.48 to 1.22, P = 0.30) or 30-day mortality (OR = 1.28, 95%CI of 0.73 to 2.23, P = 0.38) between women and men. Despite more advanced age and clustering of risk factors in women, female patients with STEMI treated by SES-based primary PCI had similar in-hospital and short-term clinical outcomes as their male counterparts.

  18. A Mechanistic Model for Drug Release in PLGA Biodegradable Stent Coatings Coupled with Polymer Degradation and Erosion

    Science.gov (United States)

    Zhu, Xiaoxiang; Braatz, Richard D.

    2015-01-01

    Biodegradable poly(D,L-lactic-co-glycolic acid) (PLGA) coating for applications in drug-eluting stents has been receiving increasing interest as a result of its unique properties compared with biodurable polymers in delivering drug for reducing stents-related side effects. In this work, a mathematical model for describing the PLGA degradation and erosion and coupled drug release from PLGA stent coating is developed and validated. An analytical expression is derived for PLGA mass loss that predicts multiple experimental studies in the literature. An analytical model for the change of the number-average degree of polymerization (or molecular weight) is also derived. The drug transport model incorporates simultaneous drug diffusion through both the polymer solid and the liquid-filled pores in the coating, where an effective drug diffusivity model is derived taking into account factors including polymer molecular weight change, stent coating porosity change, and drug partitioning between solid and aqueous phases. The model is used to describe in vitro sirolimus release from PLGA stent coating, and demonstrates the significance of simultaneous sirolimus release via diffusion through both polymer solid and pore space. The proposed model is compared to existing drug transport models, and the impact of model parameters, limitations and possible extensions of the model are also discussed. PMID:25345656

  19. Time-related changes in neointimal tissue coverage of a novel Sirolimus eluting stent

    Energy Technology Data Exchange (ETDEWEB)

    Secco, Gioel Gabrio, E-mail: gioel.gabrio.secco@gmail.com [Interventional Cardiology, “Santi Antonio e Biagio e Cesare Arrigo” Hospital, Alessandria (Italy); NIHR Biomedical Research Unit, Royal Brompton & Harefield NHS Foundation Trust, London (United Kingdom); Mattesini, Alessio [NIHR Biomedical Research Unit, Royal Brompton & Harefield NHS Foundation Trust, London (United Kingdom); Fattori, Rossella; Parisi, Rosario [Interventional Cardiology, “San Salvatore” Hospital, Pesaro (Italy); Castriota, Fausto [GVM Care and Research, Cotignola (Italy); Vercellino, Matteo [Interventional Cardiology, “Santi Antonio e Biagio e Cesare Arrigo” Hospital, Alessandria (Italy); Dall’Ara, Gianni [NIHR Biomedical Research Unit, Royal Brompton & Harefield NHS Foundation Trust, London (United Kingdom); Uguccioni, Lucia; Marinucci, Lucia [Interventional Cardiology, “San Salvatore” Hospital, Pesaro (Italy); De Luca, Giuseppe; Marino, Paolo Nicola [University of Eastern Piedmont, Novara (Italy); Pistis, Gianfranco [Interventional Cardiology, “Santi Antonio e Biagio e Cesare Arrigo” Hospital, Alessandria (Italy); Di Mario, Carlo [NIHR Biomedical Research Unit, Royal Brompton & Harefield NHS Foundation Trust, London (United Kingdom)

    2016-01-15

    Background: DES has reduced rates of restenosis compared with BMS but it has been associated with delayed healing and increase of stent thrombosis. The aim of our study was to evaluate the vascular time-related changes following implantation of a new SES coated with an amorphous silicon carbide that allows faster re-endothelisation (Orsiro-Biotronik). Methods: This prospective registry enrolled STEMI-patients with multi-vessel disease, thus candidates for a two-step procedure. PCI of the culprit lesion was performed with at least one Orsiro stent that was OCT-analysed during the second-step procedure (deferred to 30,90 and 180-days). Results: 16 of the 95 patients with MVD underwent an OCT evaluation of the study device implanted in the culprit lesion during the second-step staged procedure and were enrolled in the present Registry. A total of 3060-struts were analysed. The percentage of uncovered struts was 19.6% at30-days, 1.3% at90-days and 1.8% at180-days (p < 0.001). The percentage of cross section with ≥ 1 uncovered struts were 51.3% at30-days, 6.5% at90-days and 5.7% at180-days (p < 0.001). The percentage of cross sections containing thrombus was 6.2% at30-days while no thrombus was detected both at90 and 180-days. Conclusions: Our data shows that the new Orsiro stent promotes early and persistent strut coverage with low peri-strut thrombus. This pilot OCT evaluation might suggest a low incidence of late adverse events and anticipate safe outcome after early withdrawal of dual antiplatelet therapy. - Highlights: • This is the first serial study comparing coverage at 1, 3, and 6-months in consecutive patients with STEMI; • Aim of our study was to evaluate the vascular time-related changes following implantation of a new SES coated with an amorphous silicon carbide that allows faster re-endothelisation (Orsiro-Biotronik); • The main finding of this pilot study is that the study device presented a fast pattern of intimal coverage, with a thin intimal

  20. Everolimus-induced Pneumonitis after Drug-eluting Stent Implantation: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Susumu, E-mail: susumu1029@gmail.com; Kikuchi, Naoshi; Ichikawa, Atsuo; Sano, Go; Satoh, Keita; Sugino, Keishi; Isobe, Kazutoshi; Takai, Yujiro [Toho University School of Medicine, Department of Respiratory Medicine (Japan); Shibuya, Kazutoshi [Toho University School of Medicine, Department of Pathology (Japan); Homma, Sakae [Toho University School of Medicine, Department of Respiratory Medicine (Japan)

    2013-08-01

    Despite the wide use of everolimus as an antineoplastic coating agent for coronary stents to reduce the rate of restenosis, little is known about the health hazards of everolimus-eluting stents (EES). We describe a case of pneumonitis that developed 2 months after EES implantation for angina. Lung pathology demonstrated an organizing pneumonia pattern that responded to corticosteroid therapy. Although the efficacy of EES for ischemic heart disease is well established, EES carries a risk of pneumonitis.

  1. Vorinostat-eluting poly(DL-lactide-co-glycolide) nanofiber-coated stent for inhibition of cholangiocarcinoma cells.

    Science.gov (United States)

    Kwak, Tae Won; Lee, Hye Lim; Song, Yeon Hui; Kim, Chan; Kim, Jungsoo; Seo, Sol-Ji; Jeong, Young-Il; Kang, Dae Hwan

    2017-01-01

    The aim of this study was to fabricate a vorinostat (Zolinza™)-eluting nanofiber membrane-coated gastrointestinal (GI) stent and to study its antitumor activity against cholangiocarcinoma (CCA) cells in vitro and in vivo. Vorinostat and poly(DL-lactide-co-glycolide) dissolved in an organic solvent was sprayed onto a GI stent to make a nanofiber-coated stent using an electro-spinning machine. Intact vorinostat and vorinostat released from nanofibers was used to assess anticancer activity in vitro against various CCA cells. The antitumor activity of the vorinostat-eluting nanofiber membrane-coated stent was evaluated using HuCC-T1 bearing mice. A vorinostat-incorporated polymer nanofiber membrane was formed on the surface of the GI stent. Vorinostat was continuously released from the nanofiber membrane over 10 days, and its release rate was higher in cell culture media than in phosphate-buffered saline. Released vorinostat showed similar anticancer activity against various CCA cells in vitro compared to that of vorinostat. Like vorinostat, vorinostat released from nanofibers induced acetylation of histone H4 and inhibited histone deacetylases 1⋅3⋅4/5/7 expression in vitro and in vivo. Furthermore, vorinostat nanofibers showed a higher tumor growth inhibition rate in HuCC-T1 bearing mice than vorinostat injections. Vorinostat-eluting nanofiber membranes showed significant antitumor activity against CCA cells in vitro and in vivo. We suggest the vorinostat nanofiber-coated stent may be a promising candidate for CCA treatment.

  2. Comparison of haemodialysis patients and non-haemodialysis patients with respect to clinical characteristics and 3-year clinical outcomes after sirolimus-eluting stent implantation: insights from the Japan multi-centre post-marketing surveillance registry.

    Science.gov (United States)

    Otsuka, Yoritaka; Ishiwata, Sugao; Inada, Tsukasa; Kanno, Hiroyuki; Kyo, Eisho; Hayashi, Yasuhiko; Fujita, Hiroshi; Michishita, Ichiro

    2011-04-01

    Long-term outcomes after sirolimus-eluting stent (SES) implantation in haemodialysis (HD) patients have remained controversial. We investigated the impact of HD on outcomes after SES implantation. We analysed the data on 2050 patients who underwent SES implantation in a multi-centre prospective registry in Japan. Three-year clinical outcomes were compared between the HD group (n = 106) and the non-haemodialysis (NH) group (n = 1944). At the 3-year clinical follow-up, the rates of unadjusted cardiac mortality (HD: 16.3 vs. NH: 2.3%) and target-lesion revascularization (TLR) (HD: 19.4 vs. NH: 6.6%) were significantly higher in the HD group than the NH group (P statistical significance. Using Cox's proportional-hazard models with propensity score adjustment for baseline differences, the HD group had higher risks of TLR [HD: 16.3 vs. NH: 6.1%; hazard ratio, 2.83; 95% confidence interval (CI): 1.62-4.93, P = 0.0003] and cardiac death (HD: 12.3 vs. NH: 2.3%; hazard ratio, 5.51; 95% CI: 2.58-11.78, P < 0.0001). The consistent results of analyses, whether unadjusted or adjusted for other baseline clinical and procedural differences, identify HD as an independent risk factor for cardiac death and TLR. Percutaneous coronary intervention with SES in HD patients has a higher incidence of repeat revascularization and mortality compared with those in NH patients. Haemodialysis appears to be strongly associated with mortality and repeat revascularization even after SES implantation.

  3. A randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results.

    Science.gov (United States)

    López-Mínguez, José R; Nogales-Asensio, Juan M; Doncel-Vecino, Luis J; Merchán-Herrera, Antonio; Pomar-Domingo, Francisco; Martínez-Romero, Pedro; Fernández-Díaz, José A; Valdesuso-Aguilar, Raúl; Moreu-Burgos, José; Díaz-Fernández, José

    2014-07-01

    Up to 25% of patients who undergo a percutaneous coronary intervention show some limitation in the use of drug-eluting stents. The aim of this study was to evaluate if titanium-nitride-oxide-coated stents could be a good alternative to everolimus-eluting stents in diabetic patients. A total of 173 diabetic patients with lesions at moderate risk of restenosis (exclusion criteria: diameter 28 mm in vessels < 3mm, chronic occlusion) were randomized to a titanium group (83 patients) or an everolimus group (90 patients). Baseline characteristics were well balanced; 28.3% of patients were insulin dependent. At 1 year, the incidence of major adverse cardiac events (death, nonfatal myocardial infarction, stroke, or repeat target vessel revascularization) was significantly higher in the titanium group than in the everolimus group (total, 14.5% vs 4.4%; P = .02; noninsulin-dependent subgroup, 9.7% vs 3.2%; P = .14; insulin-dependent subgroup, 28.6% vs 7.1%; P = .04). The incidence of death, nonfatal myocardial infarction, stroke, or any revascularization was 16.9% in the titanium group and 7.8% in the everolimus group (P = .06). Target lesion and vessel revascularizations occurred in 8.4% compared with 3.3% (P = .15) and in 13.3% compared with 3.3% (P = .01) in the titanium and everolimus groups, respectively. Angiographic follow-up at 9 months showed significantly less late lumen loss in the everolimus group (in-segment, 0.52 [standard deviation, 0.58) mm vs -0.05 [0.32] mm; in-stent, 0.76 [0.54] mm vs 0.13 [0.31] mm; P < .0001). The everolimus-eluting stent is superior to the titanium stent for clinical and angiographic end points in diabetic patients with lesions at moderate risk of restenosis. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  4. Preparation of paclitaxel/chitosan co-assembled core-shell nanofibers for drug-eluting stent

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Jing; Liu, Yongjia [Instrumental Analysis Center, Shanghai Jiao Tong University, 200240 Shanghai (China); State Key Laboratory of Metal Matrix Composites, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, 200240 Shanghai (China); Zhu, Bangshang, E-mail: bshzhu@sjtu.edu.cn [Instrumental Analysis Center, Shanghai Jiao Tong University, 200240 Shanghai (China); State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Donghua University, 201620 Shanghai (China); Su, Yue; Zhu, Xinyuan [State Key Laboratory of Metal Matrix Composites, School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, 200240 Shanghai (China)

    2017-01-30

    Highlights: • The core-shell nanofibers (NFs) were made by the co-assembly of paclitaxel (PTX) and chitosan(CS). • The PTX/CS NFs have high PTX loading content, slow drug release and low adherence of platelets. • The PTX/CS NFs have low cytotoxicity and good haemocompatibility. • The PTX/CS NFs which could be easily coated on stents could have potential application for drug eluting stents. - Abstract: The paclitaxel/chitosan (PTX/CS) core-shell nanofibers (NFs) are easily prepared by co-assembly of PTX and CS and used in drug-eluting stent. The mixture solution of PTX (dissolved in ethanol) and CS (dissolved in 1% acetic acid water solution) under sonication will make the formation of NFs, in which small molecule PTX co-assembles with biomacromolecular CS through non-covalent interactions. The obtained NFs are tens to hundreds nanometers in diameter and millimeter level in length. Furthermore, the structure of PTX/CS NFs was characterized by confocal laser scanning microscopy (CLSM), zeta potential, X-ray photoelectron spectroscopy (XPS) and nanoscale infra-red (nanoIR), which provided evidences demonstrated that PTX/CS NFs are core-shell structures. The ‘shell’ of CS wrapped outside of the NFs, while PTX is located in the core. Thus it resulted in high drug loading content (>40 wt.%). The well-controlled drug release, low cytotoxicity and good haemocompatibility were also found in drug carrier system of PTX/CS NFs. In addition, the hydrophilic and flexible properties of NFs make them easily coating and filming on stent to prepare drug-eluting stent (DES). Therefore, this study provides a convenient method to prepare high PTX loaded NFs, which is a promising nano-drug carrier used for DES and other biomedical applications. The possible molecular mechanism of PTX and CS co-assembly and core-shell nanofiber formation is also explored. Statement of significance: We develop a convenient and efficient approach to fabricate core-shell nanofibers (NFs) through

  5. Vorinostat-eluting poly(DL-lactide-co-glycolide nanofiber-coated stent for inhibition of cholangiocarcinoma cells

    Directory of Open Access Journals (Sweden)

    Kwak TW

    2017-10-01

    Full Text Available Tae Won Kwak,1,* Hye Lim Lee,2,* Yeon Hui Song,2 Chan Kim,3 Jungsoo Kim,2 Sol-Ji Seo,2 Young-Il Jeong,2 Dae Hwan Kang2,4 1Medical Convergence Textile Center, Gyeongbuk, Republic of Korea; 2Biomedical Research Institute, Pusan National University Hospital, Pusan, Republic of Korea; 3Amogreentech Co. Ltd. Gyeonggi-do, Republic of Korea; 4Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Gyeongnam, Republic of Korea *These authors contributed equally to this work Purpose: The aim of this study was to fabricate a vorinostat (Zolinza™-eluting nanofiber membrane-coated gastrointestinal (GI stent and to study its antitumor activity against cholangiocarcinoma (CCA cells in vitro and in vivo. Methods: Vorinostat and poly(DL-lactide-co-glycolide dissolved in an organic solvent was sprayed onto a GI stent to make a nanofiber-coated stent using an electro-spinning machine. Intact vorinostat and vorinostat released from nanofibers was used to assess anticancer activity in vitro against various CCA cells. The antitumor activity of the vorinostat-eluting nanofiber membrane-coated stent was evaluated using HuCC-T1 bearing mice. Results: A vorinostat-incorporated polymer nanofiber membrane was formed on the surface of the GI stent. Vorinostat was continuously released from the nanofiber membrane over 10 days, and its release rate was higher in cell culture media than in phosphate-buffered saline. Released vorinostat showed similar anticancer activity against various CCA cells in vitro compared to that of vorinostat. Like vorinostat, vorinostat released from nanofibers induced acetylation of histone H4 and inhibited histone deacetylases 1·3·4/5/7 expression in vitro and in vivo. Furthermore, vorinostat nanofibers showed a higher tumor growth inhibition rate in HuCC-T1 bearing mice than vorinostat injections. Conclusion: Vorinostat-eluting nanofiber membranes showed significant antitumor

  6. Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events

    DEFF Research Database (Denmark)

    Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph

    2014-01-01

    eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. PRIMARY OUTCOMES: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite...... a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P... coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. CONCLUSIONS: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt...

  7. Incidence of periprocedural myocardial infarction following stent implantation: Comparison between first- and second-generation drug-eluting stents

    NARCIS (Netherlands)

    Tandjung, Kenneth; Basalus, Mounir W.Z.; Muurman, Esther; Louwerenburg, Hans W.; van Houwelingen, Gert K.; Stoel, Martin G.; de Man, Frits H.A.F.; Jansen, Hanneke; Huisman, Jennifer; Linssen, Gerard C.M.; Droste, Herman T.; Nienhuis, Mark B.; von Birgelen, Clemens

    2012-01-01

    Background: First- and second-generation drug-eluting stents (DES) differ in coating materials, which may influence the incidence of periprocedural myocardial infarction (PMI). Objective: To compare the incidence of PMI between first- and second-generation DES, using the current Academic Research

  8. Randomised comparison of a bioresorbable everolimus-eluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Onuma, Yoshinobu; van Boven, Ad J

    2016-01-01

    AIMS: The one-year randomised data of the ABSORB II trial showed that the everolimus-eluting bioresorbable scaffold and the everolimus-eluting metallic stent were comparable for the composite secondary clinical outcomes of patient-oriented composite endpoint (PoCE) and device-oriented composite...... Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (XIENCE; Abbott Vascular). The trial enrolled 501 patients. Clinical follow-up at two years was available in 320 patients in the Absorb BVS arm and 160 patients in the XIENCE arm. At two years, the PoCE for the Absorb and XIENCE arms......-six percent and 34% of patients remained on DAPT at two years, respectively. Ninety-two percent of patients in both arms remained on aspirin. CONCLUSIONS: Two-year clinical results demonstrate sustained low rates of PoCE, MACE, DoCE and TVF with the Absorb BVS as compared to the XIENCE stent....

  9. Application of rotational atherectomy in the drug-eluting stent era

    Science.gov (United States)

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  10. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young; Yuk, Soon Hong; Lee, Yong Seok

    2005-01-01

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models

  11. Influence of paclitaxel-eluting expandable metallic stent on tissue hyperplasia: an experimental study in a canine tracheal model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Kim, Jung Sun; Kim, Tae Hyung; Kim, Eun Young; Choi, Won Chan; Woo, Chul Woong; Di, Zhenhai; Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yuk, Soon Hong [Hannam University, College of Engineering, Daejeon (Korea, Republic of); Lee, Yong Seok [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2005-07-15

    To evaluate the efficacy of a paclitaxel-eluting expandable metallic stent in reducing tissue hyperplasia following stent placement in a canine tracheal model. Nine paclitaxel-eluting stents (drug stent, DS) consisting of a proximal bare part and a distal polyurethane-covered part were placed in the trachea of nine dogs and nine control stents (control stent, CS) were placed in the other nine dogs. The dogs were scheduled to be sacrificed 12 weeks after stent placement. Gross and histological factors, such as epithelial erosion/ulcer, granulation tissue thickness and inflammatory cell infiltration were evaluated after each dog was sacrificed. There were no procedure-related complications or malpositioning of any of the stents. One CS migrated less than eight weeks following stent placement. Four dogs (one DS and three CS dogs) died between three and five weeks following stent placement. Therefore, pathologic specimens were obtained from eight DS and five CS dogs. Epithelial erosion/ulcer or inflammatory cell infiltration was slightly more prominent in the DS cases than in the CS cases, in both the bare part and the covered part. However, the data was not statistically significant. Granulation tissue thickness was lower in the DS cases than in the CS cases in both the bare part (mean, 3.63-mm vs. 4.37-mm) and the covered part (mean, 1.75-mm vs. 2,78 mm), but the data was also statistically insignificant. Although the data was not statistically significant, placement of paclitaxel-eluting expandable metallic stent demonstrates a tendency toward a decrease in granulation tissue thickness in canine tracheal models.

  12. Efectos biológicos de los stents medicados en la circulación coronaria Biological effects of drug-eluting stents in the coronary circulation

    Directory of Open Access Journals (Sweden)

    Darío Echeverri

    2010-04-01

    Full Text Available Los stents medicados ofrecen la mejor alternativa disponible no quirúrgica para el tratamiento de la enfermedad coronaria gracias a su demostrada eficacia. Sin embargo, estos excelentes resultados han sido opacados en términos de seguridad, principalmente por la presencia de trombosis de stents de manera tardía o muy tardía. La comprensión de los efectos biológicos que ejercen a nivel de la arteria coronaria luego de su implante, se debe al efecto de la plataforma utilizada, el polímero y la droga que liberan. Los trastornos de reparación vascular inducidos favorecen la trombosis de stents y sus consecuencias clínicas. Se hace una revisión de los diferentes efectos biológicos de los stents medicados en las arterias coronarias, que permite comprender como han surgido rápidamente nuevas versiones en materiales, diseños, polímeros y medicamentos que reducen los efectos adversos a nivel coronario, mejorando su eficacia y seguridad.Drug-eluting stents offer the best available non-surgical alternative for the treatment of coronary disease, thanks to its demonstrated efficacy. However, in terms of security, these excellent results have been overshadowed by the late or very late appearance of stent thromboses.The biological effects they have in the coronary artery after its implantation are due to the effect of the platform used, the polymer and the medication released. The vascular healing disorders induced by drug-eluting stents favor stent thrombosis and its clinical consequences. This is a review of the different biological effects of drug-eluting stents in coronary arteries that allows to understand how the rapid onset of new versions of materials, designs, polymers and medications diminish adverse coronary effects and improve its efficacy and safety.

  13. Impact of Age on Long-Term Outcome After Primary Angioplasty With Bare-Metal or Drug-Eluting Stent (From the DESERT Cooperation)

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian

    2013-01-01

    Despite mechanical reperfusion, elderly patients with ST-segment elevation myocardial infarction (STEMI) still experience unsatisfactory outcomes. Drug-eluting stents (DES) have significantly reduced target-vessel revascularization (TVR), but concerns have emerged about the higher risk of late st...... angioplasty and stent implantation included in the Drug-Eluting Stent in Primary Angioplasty (DESERT) Cooperation database. Age was significantly associated with female gender (p...

  14. Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era

    Directory of Open Access Journals (Sweden)

    Mehrdad Taherioun

    2014-01-01

    Full Text Available BACKGROUND: Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon. METHODS: After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angiographic result confirmed by the operator, intravascular ultrasound (IVUS was performed for all the treated lesions. If the treated lesions fulfilled the IVUS criteria, they are considered as the optimal stent group; if not, they are considered as the suboptimal group. RESULTS: From 50 patients enrolled in this study 39 (78% had optimal stent deployment and 11 (22% had suboptimal stent deployment. In the suboptimal group 7 (14% had underexpansion, 2 (4% malposition, and 2 (4% had asymmetry. There were no stent edge dissections detected by IVUS. We did not find any correlation between lesion calcification, ostial lesions, stent length, and stent underexpansion. Stent diameter ≤ 2.75 mm had a strong correlation with stent underexpansion. CONCLUSION: Despite adjunctive post-dilatation with noncompliant balloon, using a relatively small stent diameter was a strong predictor for underexpansion. IVUS guided percutaneous coronary intervention (PCI may be considered for drug eluting stent (DES implantation in relatively small vessels.   Keywords: Stent, Percutaneous Coronary Intervention, Ultrasound, Post-dilatation 

  15. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease: A Meta-Analysis of Individual Patient Data.

    Science.gov (United States)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung

    2016-12-26

    The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly pronounced in those with multivessel CAD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  16. Impact of stent length on clinical outcomes of first-generation and new-generation drug-eluting stents.

    Science.gov (United States)

    Konishi, Hirokazu; Miyauchi, Katsumi; Dohi, Tomotaka; Tsuboi, Shuta; Ogita, Manabu; Naito, Ryo; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Daida, Hiroyuki

    2016-04-01

    The aim of this study is to compare first- and new-generation drug-eluting stents (DESs) which are implanted in long lesion. Stent length is known to be a predictor of adverse events after percutaneous coronary intervention (PCI), even with the first-generation DESs. The introduction of new-generation DESs has reduced the rates of adverse clinical events. However, the impact of stent length on long-term clinical outcomes is not well known. A total of 1181 consecutive patients who underwent PCI using either a first-generation DES (n = 885) or a new-generation DES (n = 296) between 2004 and 2011 were investigated. In each of the stent groups, the patients were divided into two groups by stent length (>32 and ≤32 mm) and compared. During the follow-up period, the incidence of major adverse cardiac events (MACEs) was significantly higher for patients with long stents implanted than with short stents (P stent groups in the new-generation DES group (P = 0.24; log-rank test). On multivariate Cox regression analysis, stent length was not associated with adverse events in the new-generation DES groups [hazard ratio (HR) 0.87; 95 % confidence interval (95 % CI) 0.71-1.04; P = 0.14]. Implanted stent length was significantly associated with a higher risk of MACEs in patients who received first-generation DESs, but not in patients who received the new-generation DESs.

  17. Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Mintz, Gary S

    2009-01-01

    Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston......-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.......1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2...

  18. Comparing Stent Thrombosis associated with Zotarolimus Eluting Stents versus Everolimus Eluting Stents at 1 year follow up: a systematic review and meta-analysis of 6 randomized controlled trials.

    Science.gov (United States)

    Bundhun, Pravesh Kumar; Yanamala, Chandra Mouli; Huang, Wei-Qiang

    2017-03-16

    Two thousand fifteen has been a winning year for Drug Eluting Stents (DES). Increase in the number of patients with cardiovascular diseases treated by Percutaneous Coronary Intervention (PCI) has resulted to a high demand for second generation DES. This current analysis aimed to compare the different types of Stent Thrombosis (ST) associated with Zotarolimus Eluting Stents (ZES) versus Everolimus Eluting Stents (EES) at 1 year follow up. Electronic databases were searched for studies comparing ZES with EES. Different types of ST reported at 1 year follow up were considered as the primary endpoints in this analysis. Odds Ratios (OR) with 95% Confidence Intervals (CIs) were used as the statistical parameters and the pooled analyses were carried out by the RevMan 5 · 3 software. A total number of 10,512 patients were included in this analysis. No significant difference in any definite ST, acute definite ST, subacute definite ST, and late definite ST were observed between ZES and EES, at 1 year follow up with OR: 1.70, 95% CI: 0.92 - 3.16; P = 0.09, OR: 3.44, 95% CI: 0.82 - 14.43; P = 0.09, OR: 1.13, 95% CI: 0.43 - 2.95; P = 0.80 and OR: 2.39, 95% CI: 0.83 - 6.85; P = 0.11 respectively. Moreover, any definite or probable ST and definite/probable/possible ST were also not significantly different with OR: 1.39, 95% CI: 0.89 - 2.17; P = 0.15 and OR: 1.19, 95% CI: 0.84 - 1.70; P = 0.33 respectively. In addition, any probable ST, acute probable ST, late probable ST and possible ST were also not significantly different at 1 year follow up with OR: 1.11, 95% CI: 0.60 - 2.05; P = 0.75, OR: 0.53, 95% CI: 0.12 - 2.40; P = 0.41, OR: 1.67, 95% CI: 0.35 - 7.86; P = 0.52 and OR: 1.08, 95% CI: 0.64 - 1.82; P = 0.78 respectively. At 1 year follow up, ZES were not associated with significantly lower or higher definite and probable ST compared to EES. In addition, no significant difference was observed in acute, subacute and late

  19. In-stent neoatherosclerosis and tissue characteristics of restenotic lesions following implantation of second generation drug-eluting stents in unrestricted coronary lesions: Optical frequency domain imaging study.

    Science.gov (United States)

    Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed

    2017-06-01

    Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.

  20. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: 3-year follow-up of the randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) Trial

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Kelbaek, Henning; Thuesen, Leif

    2010-01-01

    The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).......The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI)....

  1. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon; Seo, Tae-Seok; Yuk, Soon Hong; Kim, Young-Hwa; Cho, Yong-Mee

    2005-01-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  2. Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Choi, Gi Bok; Kim, Tae-Hyung; Suh, Ji-Yeon [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, Seoul (Korea); Seo, Tae-Seok [Gachon Medical School, Department of Radiology, Gil Medical Center, Inchon (Korea); Yuk, Soon Hong [Hannam University, Department of Polymer Science and Engineering, College of Engineering, Daejeon (Korea); Kim, Young-Hwa [Soonchunhyang University Chonan Hospital, Department of Radiology, Chonan (Korea); Cho, Yong-Mee [University of Ulsan College of Medicine, Department of Pathology, Asan Medical Center, Seoul (Korea)

    2005-06-01

    This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean{+-}standard deviation, 46.88{+-}23.75) than in the CS (73.75{+-}14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63{+-}2.05) than in CS (3.49{+-}2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model. (orig.)

  3. Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFORTABLE-AMI (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) trials.

    Science.gov (United States)

    Sabaté, Manel; Räber, Lorenz; Heg, Dik; Brugaletta, Salvatore; Kelbaek, Henning; Cequier, Angel; Ostojic, Miodrag; Iñiguez, Andrés; Tüller, David; Serra, Antonio; Baumbach, Andreas; von Birgelen, Clemens; Hernandez-Antolin, Rosana; Roffi, Marco; Mainar, Vicente; Valgimigli, Marco; Serruys, Patrick W; Jüni, Peter; Windecker, Stephan

    2014-01-01

    This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up. Copyright © 2014 American

  4. Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers

    Directory of Open Access Journals (Sweden)

    Brendan Doyle

    2009-11-01

    Full Text Available Brendan Doyle, David R Holmes JrDivision of Cardiovascular Diseases, Department of Internal Medicine, Mayo Clinic College of Medicine, Rochester, Minnesota, USAAbstract: The success of drug-eluting stents in preventing restenosis has shifted the focus of new stent development toward enhancing long term safety and efficacy of these devices, while simultaneously eliminating the need for indefinite dual antiplatelet therapy. A technical advance fulfilling these aims would hold tremendous potential to reduce morbidity, mortality and economic costs associated with the percutaneous treatment of coronary artery disease. An attractive approach is the use of bioabsorbable stent designs. These may include stents with different bioabsorbable drugs, bioabsorbable polymers or even bioabsorbable metallic backbones. A device that could achieve excellent acute and long-term results, but disappear completely within months (thereby avoiding the need for prolonged dual antiplatelet therapy, would be a tremendous advance. Too good to be true? We explore here the scientific rationale and prospects for success with this exciting concept.Keywords: percutaneous coronary intervention, biodegradable, bioabsorbable, polymer, stent

  5. Local perivascular delivery of anti-restenotic agents from a drug-eluting poly(ε-caprolactone) stent cuff

    NARCIS (Netherlands)

    Pires, N.M.M.; Hoeven, B.L. van der; Vries, M.R. de; Havekes, L.M.; Vlijmen, B.J. van; Hennink, W.E.; Quax, P.H.A.; Jukema, J.W.

    2005-01-01

    The introduction of drug-eluting stents (DES) to prevent in-stent restenosis is one of the major advances in interventional cardiology. Currently many types of DES are under evaluation for effectiveness and safety, a time-consuming and difficult procedure in humans. An animal model that allows rapid

  6. Paclitaxel-eluting stents versus everolimus-eluting coronary stents in a diabetic population: two-year follow-up of the TUXEDO-India trial.

    Science.gov (United States)

    Kaul, Upendra; Bhagwat, Ajit; Pinto, Brian; Goel, Praveen K; Jagtap, Prashant; Sathe, Shireesh; Wander, Gurpreet S; Arambam, Priyadarshini; Bangalore, Sripal

    2017-11-20

    The aim of this study was to report whether the superiority of the everolimus-eluting stent (EES) vs. the paclitaxel-eluting stent (PES) at one-year follow-up in the Taxus Element versus Xience Prime in a Diabetic Population (TUXEDO)-India trial was sustained at longer-term follow-up. One thousand eight hundred and thirty (1,830) patients with diabetes mellitus and coronary artery disease were randomised to EES vs. PES. Follow-up data up to two years were available in 1,701 (92.9%) patients. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, target vessel myocardial infarction (TV-MI), or ischaemia-driven target vessel revascularisation (TVR). Treatment with EES had a lower two-year rate of TVF (4.3% vs. 6.6%, p=0.03). Of the secondary endpoints, EES significantly reduced any MI (1.6% vs. 3.5%, p=0.01), TV-MI (0.7% vs. 3.1%, p=0.0001), ST (0.4% vs. 2.2%, p=0.001), cardiac death or target vessel MI (2.9% vs. 4.8%, p=0.04) and TLR (1.9% vs. 3.7%, p=0.02), compared with PES. Between one year and two years, no significant differences in the clinical outcomes were observed (pinteraction >0.05). In this adequately powered trial, the benefits of EES vs. PES in a diabetic population seen at one year were maintained at two years.

  7. The Impact of Post-Procedural Asymmetry, Expansion, and Eccentricity of Bioresorbable Everolimus-Eluting Scaffold and Metallic Everolimus-Eluting Stent on Clinical Outcomes in the ABSORB II Trial.

    Science.gov (United States)

    Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu

    2016-06-27

    The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p 0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281). Copyright © 2016 American

  8. Avaliação da endotelização de hastes de stents em artérias ilíacas de coelhos

    Directory of Open Access Journals (Sweden)

    Celso Kiyochi Takimura

    Full Text Available FUNDAMENTO: A rápida endotelização pós-implante de stent é ocorrência desejável por teoricamente reduzir a possibilidade de trombose do stent. OBJETIVO: Avaliar a extensão da endotelização de hastes de stents eluidores de sirolimus (liberados da face luminal e abluminal e abluminal exclusivamente em artérias ilíacas de coelhos. MÉTODOS: Foram implantados em artérias ilíacas de 10 coelhos quatro stents eluidores de sirolimus na face luminal e abluminal, três stents eluidores de sirolimus na face abluminal, seis stents recobertos com polímero e quatro stents sem recobrimento. Após quatro semanas, foi realizada eutanásia e utilizou-se microscopia eletrônica de varredura para quantificação da área de hastes de stent exposta e da porcentagem de endotelização. RESULTADOS: A área (média ± DP (mm² de hastes expostas de stent sem recobrimento, stent recoberto com polímero, stent eluidor de sirolimus na face luminal e abluminal e stent eluidor de sirolimus na face abluminal foi de 0,12 ± 0,08; 0,09 ± 0,12; 0,60 ± 0,67 e 0,05 ± 0,04 respectivamente (p = 0,120. A porcentagem de endotelização (média ± DP (% de stent sem recobrimento, stent recoberto com polímero, stent eluidor de sirolimus na face luminal e abluminal e stent eluidor de sirolimus na face abluminal foi de 99 ± 01; 99 ± 0; 97 ± 03 e 99 ± 0 respectivamente (p = 0,133. CONCLUSÃO: Após quatro semanas de implante em artérias ilíacas de coelhos, os stents com liberação de sirolimus tanto da face luminal e abluminal quanto da face abluminal exclusivamente apresentaram taxas de endotelização de hastes de stent semelhantes aos apresentados nos demais tipos de stents sem eluição de medicamento.

  9. The effect of local sustained delivery of sirolimus on the vascular PAI-1 and t-PA expression after angioplasty

    International Nuclear Information System (INIS)

    E Yajun; He Nengshu; Fan Hailun

    2011-01-01

    Objective: To investigate the effect of local sustained delivery of sirolimus on the vascular inhibitor of plasminogen activator-1 (PAI-1) and tissue type plasminogen activator (t-PA) expression after angioplasty. Methods: Experimental common carotid artery injury model was established in the rats. A total of 30 male Wistar rats were divided into experimental group (n=20) and control group (n=10). Adventitial administration of drug was applied. Pluronic F-127 gel containing sirolimus was administered to the exposed adventitial surface of injured carotid artery. The experimental group was divided into high concentration (600 μg/100 μl) sub-group and low concentration (300 μg/100μl) sub-group according to the concentration of sirolimus delivered. The effect of local sustained delivery sirolimus on vascular PAI-1 and t-PA expression after percutaneous angioplasty was evaluated by immunohistochemistry. Results: Compared to control group, 15 and 30 days after injury local sustained delivery of sirolimus in both high concentration and low concentration sub-groups the expression of the PAI-1 in neointima was significantly enhanced (P 0.05). At 15 and 30 days after injury, the expression of t-PA in neointima was decreased in both high and low concentration sub-groups (P<0.05), and the expression of t-PA in media was significantly decreased in high concentration sub-group (P<0.05) while on significant difference could be detected in low concentration sub-group. Conclusion: Local sustained delivery of sirolimus can induce the high expression of PAI-1 and low expression of t-PA in neointima although it inhibits the proliferation of neointima in the same time, and the imbalanced expression of t-PA and PAI-1 may probably play an important role in the late formation of thrombosis after the placement of drug-eluting stent. (authors)

  10. The prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: a substudy of the RESOLUTE All Comers Trial

    DEFF Research Database (Denmark)

    Garg, Scot; Serruys, Patrick W; Silber, Sigmund

    2011-01-01

    This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents.......This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents....

  11. Antirestenotic Effects of a Novel Polymer-Coated D-24851 Eluting Stent. Experimental Data in a Rabbit Iliac Artery Model

    International Nuclear Information System (INIS)

    Lysitsas, Dimitrios N.; Katsouras, Christos S.; Papakostas, John C.; Toumpoulis, Ioannis K.; Angelidis, Charalampos; Bozidis, Petros; Thomas, Christopher G.; Seferiadis, Konstantin; Psychoyios, Nikolaos; Frillingos, Stathis; Pavlidis, Nikolaos; Marinos, Euaggelos; Khaldi, Lubna; Sideris, Dimitris A.; Michalis, Lampros K.

    2007-01-01

    Experimental and clinical data suggest that stents eluting antiproliferative agents can be used for the prevention of in-stent restenosis. Here we investigate in vitro the antiproliferative and apoptotic effect of D-24851 and evaluate the safety and efficacy of D-24851-eluting polymer-coated stents in a rabbit restenosis model (n = 53). Uncoated stents (n = 6), poly (dl-lactide-co-glycolide) (PLGA)-coated stents (n = 7), and PLGA-coated stents loaded with 0.08 ± 0.0025 μM (31 ± 1 μg; low dose; n = 7), 0.55 ± 0.02 μM (216 ± 8 μg; high dose; n = 6), and 4.55 ± 0.1 μM (1774 ± 39 μg; extreme dose; n = 5) of D-24851 were randomly implanted in New Zealand rabbit right iliac arteries and the animals were sacrificed after 28 days for histomorphometric analysis. For the assessment of endothelial regrowth in 90 days, 12 rabbits were subjected to PLGA-coated (n = 3), low-dose (n = 3), high-dose (n = 3), and extreme-dose (n = 3) stent implantation. In vitro studies revealed that D-24851 exerts its growth inhibitory effects via inhibition of proliferation and induction of apoptosis without increasing the expression of heat shock protein-70, a cytoprotective and antiapoptotic protein. Treatment with low-dose D-24851 stents was associated with a significant reduction in neointimal area and percentage stenosis only compared with bare metal stents (38% [P = 0.029] and 35% [P = 0.003] reduction, respectively). Suboptimal healing, however, was observed in all groups of D-24851-loaded stents in 90 days in comparison with PLGA-coated stents. We conclude that low-dose D-24851-eluting polymer-coated stents significantly inhibit neointimal hyperplasia at 28 days through inhibition of proliferation and enhancement of apoptosis. In view of the suboptimal re-endothelialization, longer-term studies are needed in order to establish whether the inhibition of intimal growth is maintained

  12. Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis

    Science.gov (United States)

    Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter

    2014-01-01

    Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably

  13. Drug-eluting stent implantation for the percutaneous treatment of vertebro-basilar arterial stenosis

    International Nuclear Information System (INIS)

    Ma Rujun; Liu Jianmin; Huang Haiqing; Hong Bo; Xu Yi; Zhao Wenyuan; Zhao Rui; Chen Jun

    2006-01-01

    Objective: To evaluate the early results and mid-term outcomes following angioplasty of vertebro-basilar arterial stenosis with drug-eluting stents. Methods: All of the patients presented with recurrent TIA or ceretral infarction with >50% stenoses in vertebro-basilar arteries, and having failure in maximal medical therapy. All of the lesions were treated with primary stenting under local or general anesthesia and followed by continual anticoagulant therapy of clopidogrel and aspirin together with clinical follow-up and vascular imagings. Results: Of 28 stenoses (27 patients), 27 lesions were successfully treated with implantation of 24 Cypher stents, 2 Taxus stents and one Firebird stent. The mean stenotic severity reduced from (74 ± 6.7)% to (8.7 ± 4.4)%. Two patients had inchemic events relating to penetration vascular obstruction. During 2-14 months follow-up, the patients were clinically asymptomatic with no recurrent TIA/stoke. Angiographic follow-up was obtained in 14 patients at a mean of 7.2 months. Proximal restenosis (<50%) occurred in one patient (3.3%), and corrected with restenting, while others were free of intra-stent restenoses. Conclusion: Using DES in cerebrovascular stenosis is safe and effective with lowing the risk of intra-stent restenosis in comparison with bare stent. Further study for long term efficiency is still in need. (authors)

  14. Disappearing and reappearing differences in drug-eluting stent use by race.

    Science.gov (United States)

    Federspiel, Jerome J; Stearns, Sally C; Reiter, Kristin L; Geissler, Kimberley H; Triplette, Matthew A; D'Arcy, Laura P; Sheridan, Brett C; Rossi, Joseph S

    2013-04-01

    Drug-eluting coronary stents (DES) rapidly dominated the marketplace in the United States after approval in 2003, but utilization rates were initially lower among African American patients. We assess whether racial differences persisted as DES diffused into practice. Medicare claims data were used to identify coronary stenting procedures among elderly patients with acute coronary syndromes (ACS). Regression models of the choice of DES versus bare mental stent controlled for demographics, ACS type, co-morbidities and hospital characteristics. Diffusion was assessed in the short run (2003-2004) and long run (2007), with the effect of race calculated to allow for time-varying effects. The sample included 381,887 Medicare beneficiaries treated with stent insertion; approximately 5% were African American. Initially (May 2003-February 2004), African American race was associated with lower DES use compared to other races (44.3% versus 46.5%, P differences were not significant (79.8% versus 80.3%, P = 0.45). Subsequent concerns regarding DES safety caused reductions in DES use, with African Americans having lower use than other racial groups in 2007 (63.1% versus 65.2%, P differences in race reflect decisions regarding treatment appropriateness. © 2011 Blackwell Publishing Ltd.

  15. A randomized, controlled, multicenter trial to evaluate the safety and efficacy of Zotarolimus- vs. Paclitaxel-eluting stents in de novo occlusive lesions in coronary arteries

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Dimario, Carlo; Neumann, Franz-Josef

    2013-01-01

    The ZOMAXX I trial tested the noninferiority of a zotarolimus-eluting coronary stent (ZoMaxx(™) ) when compared with a paclitaxel-eluting coronary stent (Taxus(™) Express(2™) ) in a randomized trial of percutaneous intervention for de novo coronary artery stenosis. Angiographic analysis at the pr...

  16. Clinical evaluation of domestic biodegradable drug-eluting stents in the treatment of coronary heart disease

    International Nuclear Information System (INIS)

    Yu Hongying; Suo Chuantao; Shang Ruiping

    2009-01-01

    Objective: To evaluate the safety and efficacy of domestic biodegradable drug-eluting stent, EXCEL, in clinical treatment of coronary heart disease. Methods: During the period of Jan. 2008-Oct. 2008, 100 patients with coronary heart disease who consented to PCI and postoperative coronary angiography were selected and enrolled in the study. The patients were divided into EXCEL group (n = 58) and Cypher group (n = 42). The immediate successful rate of interventional therapy and the complications occurred during hospitalization were observed. Postoperative follow-up and checkup coronary angiography were conducted. Results: No significant difference in the relevant clinical data, in the number and type of diseased coronary branch and in the mean length of implanted stents existed between two groups. Also, no statistically significant difference in the occurrence of major adverse cardiac event (MACE), in-stent restenosis and thrombosis was present between two groups. Conclusion: Compared with Cypher stenting, EXCEL stenting carries similar, i.e. rather low, occurrence of MACE and in-stent restenosis. (authors)

  17. Use of drug-eluting stents in Victorian public hospitals.

    Science.gov (United States)

    Yan, Bryan P; Ajani, Andrew E; Duffy, Stephen J; New, Gishel; Horrigan, Mark; Szto, Gregory; Walton, Antony; Eccleston, David; Lefkovits, Jeffery; Black, Alexander; Sebastian, Martin; Brennan, Angela L; Reid, Christopher M; Clark, David J

    2006-10-02

    We aimed to assess the pattern of use of drug-eluting stents (DESs) in patients undergoing percutaneous coronary interventions (PCIs) in Victorian public hospitals. Prospective study comparing the use of one or more DESs versus bare-metal stents (BMSs) only, in consecutive patients undergoing 2428 PCIs with stent implantation from 1 April 2004 to 31 December 2005 at seven Victorian public hospitals. Adherence to current Victorian Department of Human Services guidelines which recommend DES use in patients with high-risk features for restenosis (diabetes, small vessels, long lesions, in-stent restenotic lesions, chronic total occlusions and bifurcation lesions). Of the 2428 PCIs performed, at least one DES was implanted in 1101 (45.3%) and BMSs only were implanted in 1327 (54.7%). In 87.7% (966/1101) of PCI with DESs, there was at least one criterion for high risk of restenosis. DESs were more likely to be used in patients with diabetes (risk ratio [RR], 2.45; 95% CI, 2.02-2.97), small vessels (RR, 3.35; 95%CI, 2.35-4.76), long lesions (RR, 3.87; 95% CI, 3.23-4.65), in-stent restenotic lesions (RR, 3.98; 95%CI, 2.67-6.06), chronic total occlusions (RR, 1.30; 95% CI, 0.51-2.88) and bifurcation lesions (RR, 2.23; 95%CI, 1.57-3.17). However, 66.2% (1608/2428) of all PCIs were in patients eligible for DESs according to Victorian guidelines, and in 39.9% (642/1608) of these PCIs, a BMS was used. In Victorian public hospitals, DESs have been largely reserved for patients at high risk of restenosis in accordance with Department of Human Services guidelines. However, many patients with high-risk criteria for restenosis did not receive DESs. Greater use of DESs in these patients may improve outcomes by reducing the need for repeat revascularisation.

  18. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Chevalier, Bernard; Sotomi, Yohei; Cequier, Angel; Carrié, Didier; Piek, Jan J.; van Boven, Ad J.; Dominici, Marcello; Dudek, Dariusz; McClean, Dougal; Helqvist, Steffen; Haude, Michael; Reith, Sebastian; de Sousa Almeida, Manuel; Campo, Gianluca; Iñiguez, Andrés; Sabaté, Manel; Windecker, Stephan; Onuma, Yoshinobu

    2016-01-01

    No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a result of

  19. Association of localized hypersensitivity and in-stent neoatherosclerosis with the very late drug-eluting stent thrombosis.

    Directory of Open Access Journals (Sweden)

    Kyohei Yamaji

    Full Text Available Localized hypersensitivity reaction, delayed arterial healing, and neoatherosclerosis inside the stent have been suggested as the underlying pathologic mechanisms of very late stent thrombosis (VLST of drug-eluting stent (DES. The present study sought to explore the prevalence of inflammatory cell infiltrates and evidence for fragments of atherosclerotic plaques in the aspirated thrombi in patients with DES VLST.From April 2004 to September 2012, 48 patients with stent thrombosis (ST of DES underwent thrombus aspiration with retrieved material sufficient for the histopathologic analysis; early ST (EST, within 30 days: N = 17, late ST (LST, between 31 and 365 days: N = 7, and very late ST (VLST, >1 year: N = 24. Eosinophil fraction in the aspirated thrombi was significantly higher in patients with VLST (8.2±5.7% as compared with those with EST (4.3±3.0% and LST (5.5±3.8% (P = 0.03. Eosinophil fraction in the aspirated thrombi was significantly higher in 12 VLST patients with angiographic peri-stent contrast staining (PSS and/or incomplete stent apposition (ISA by intravascular ultrasound than in 12 VLST patients without PSS or ISA (10.6±6.1% versus 5.8±4.1%, P = 0.03. Evidences for fragments of atherosclerotic plaques in the aspirated thrombi were observed only in 3 (13% out of 24 patients with DES VLST.Eosinophil fraction in the aspirated thrombi was significantly higher in patients with DES VLST as compared with those with EST and LST. Evidences for fragments of atherosclerotic plaques were relatively uncommon in patients with DES VLST.

  20. Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents.

    Science.gov (United States)

    Choi, Woong Gil; Kim, Soo Hyun; Yoon, Hyung Seok; Lee, Eun Joo; Kim, Dong Woon

    2015-01-01

    Although drug-eluting stents (DESs) effectively reduce restenosis following percutaneous coronary intervention (PCI), they also delay re-endothelialization and impair microvascular function, resulting in adverse clinical outcomes. Endothelial progenitor cell (EPC) capturing stents, by providing a functional endothelial layer on the stent, have beneficial effects on microvascular function. However, data on coronary microvascular function in patients with EPC stents versus DESs are lacking. Seventy-four patients who previously underwent PCI were enrolled in this study. Microvascular function was evaluated 6 months after PCI based on the index of microvascular resistance (IMR) and the coronary flow reserve (CFR). IMR was calculated as the ratio of the mean distal coronary pressure at maximal hyperemia to the inverse of the hyperemic mean transit time (hTmn). The CFR was calculated by dividing the hTmn by the baseline mean transit time. Twenty-one patients (age, 67.2 ± 9.6 years; male:female, 15:6) with an EPC stent and 53 patients (age, 61.5 ± 14.7 years; male:female, 40:13) with second-generation DESs were included in the study. There were no significant differences in the baseline clinical and angiographic characteristics of the two groups. Angiography performed 6 months postoperatively did not show significant differences in their CFR values. However, patients with the EPC stent had a significantly lower IMR than patients with second-generation DESs (median, 25.5 [interquartile range, 12.85 to 28.18] vs. 29.0 [interquartile range, 15.42 to 39.23]; p = 0.043). Microvascular dysfunction was significantly improved after 6 months in patients with EPC stents compared to those with DESs. The complete re-endothelialization achieved with the EPC stent may provide clinical benefits over DESs, especially in patients with microvascular dysfunction.

  1. The Promus Premier everolimus-eluting platinum chromium stent with durable polymer evaluated in a real world all-comer population in Rotterdam cardiology hospital (the P-SEARCH registry)

    NARCIS (Netherlands)

    Lemmert, M.E.; Mieghem, N.M. van; Geuns, R.J.M. van; Diletti, R.; Bommel, R.J. van; Domburg, R.T. van; Jaegere, P.P. de; Regar, E.; Zijlstra, F.; Boersma, E.; Daemen, J.

    2017-01-01

    BACKGROUND: A new-generation everolimus eluting platinum-chromium stent (EePCS), offering improved radial strength, radiopacity and conformability compared to everolimus-eluting cobalt-chromium stents (EeCCS), was evaluated with regard to safety and efficacy in an all-comer cohort. METHODS: A total

  2. First-in-man study of simvastatin-eluting stent in de novo coronary lesions: the SIMVASTENT study.

    Science.gov (United States)

    Zago, Alexandre C; Matte, Bruno S; Reginato, Luciana; Iturry-Yamamoto, Germán; Krepsky, Ana; Bergoli, Luiz Carlos C; Balvedi, Julise; Raudales, José C; Saadi, Eduardo K; Zago, Alcides J

    2012-01-01

    Statins have anti-inflammatory and antiproliferative properties irrespective of their cholesterol-lowering effects. The aim of the present study was to evaluate a simvastatin-eluting stent (SimvES) in the treatment of de novo coronary lesions. Forty-two patients with de novo coronary artery lesions were assigned to SimvES, bare-metal stent (BMS) or everolimus-eluting stent (EES) implantation followed by intravascular ultrasound (IVUS) for neointimal quantitative analysis. Six months later, quantitative coronary angiography (QCA) and IVUS were repeated. QCA showed no binary restenosis, a mean in-stent late loss of 1.05 ± 0.25 mm (BMS, 1.12 ± 0.48 mm; EES, 0.20 ± 0.16 mm) and a diameter stenosis of 33.5 ± 7.1% (BMS, 35.5 ± 15.30%; EES, 7.2 ± 3.12%). Control IVUS showed a mean in-stent obstruction of 18.3 ± 9.4% (BMS, 32.8 ± 19.1%; EES, 9.8 ± 2.4%) and a neointimal volume index of 1.58 ± 0.75 mm(3)/mm (BMS, 2.93 ± 1.76 mm(3)/mm; EES, 0.80 ± 0.16 mm(3)/mm). Thrombus, late incomplete apposition and major adverse cardiac events were not observed. In this sample of patients with de novo coronary lesions, the use of a SimvES was not related to major adverse cardiac events, but it was associated with a higher level of neointimal proliferation than expected.

  3. Long-term clinical outcome in STEMI patients treated with primary PCI and drug-eluting or bare-metal stents: insights from a high-volume single-center registry

    DEFF Research Database (Denmark)

    Pedersen, Sune; Galatius, Soren; Mogelvang, Rasmus

    2011-01-01

    Use of drug-eluting stents (DES) in patients with ST-elevation myocardial infarction (STEMI) during routine primary percutaneous coronary intervention (pPCI) is controversial.......Use of drug-eluting stents (DES) in patients with ST-elevation myocardial infarction (STEMI) during routine primary percutaneous coronary intervention (pPCI) is controversial....

  4. Optical Coherence Tomography Substudy of A Prospective Multicenter Randomized Post-Market Trial to Assess the Safety and Effectiveness of the Firehawk™ Rapamycin Target Eluting Cobalt Chromium Coronary Stent System for the Treatment of Atherosclerotic Lesions: TARGET All Comers.

    Science.gov (United States)

    Baumbach, Andreas; Lansky, Alexandra J; Onuma, Yoshi; Asano, Taku; Johnson, Thomas; Anderson, Richard; Kiemeneij, Ferdinand; Zheng, Ming; Van Royen, Niels; Slagboom, Ton; Vlachojannis, Georg; Xu, Bo; Serruys, Patrick; Wijns, William

    2018-06-12

    Durable polymer drug-eluting stents (DP DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this Optical Coherence Tomography (OCT) sub-study was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (FIREHAWK®) (BP DES) versus the DP DES (XIENCE) at 90 days in an all comers patient population. The TARGET All Comers study is a prospective multicenter randomised post-market trial of 1656 patients randomised 1:1 to FIREHAWK or XIENCE at 21 centers in 10 European countries. The TARGET OCT sub-study enrolled 36 consecutive patients with 52 lesions at 6 centers proficient in OCT. Follow-up OCT was performed at 3 months or prior to revascularisation when occurring before the 3-month window. The substudy was designed for non-inferiority of the primary endpoint of neointimal thickness. At follow-up, the mean neointimal thickness by OCT (52 lesions, Firehawk, n=24; Xience, n=28), was not significantly different between groups (Firehawk 75.5μm vs Xience V 82.3 μm) meeting the primary endpoint of non-inferiority (Pnoninferiority<0.001). The percentage of stent strut coverage was high in both groups (strut level: 99.9% ± 0.3 vs 100% ± 0.1, p=0.26), and the proportion of malapposed struts (1.0±1.6% vs. 1.2±2.0%, p=0.51) was low in both groups. Based on OCT, the FIREHAWK BP DES has a similar healing response 3 months after implantation compared to the DP DES, with near complete strut coverage, moderate neointima formation and minimal strut malapposition.

  5. Factors that affect mass transport from drug eluting stents into the artery wall

    Directory of Open Access Journals (Sweden)

    Walsh Michael T

    2010-03-01

    Full Text Available Abstract Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.

  6. Stent Thrombosis in Drug-Eluting or Bare-Metal Stents in Patients Receiving Dual Antiplatelet Therapy.

    Science.gov (United States)

    Kereiakes, Dean J; Yeh, Robert W; Massaro, Joseph M; Driscoll-Shempp, Priscilla; Cutlip, Donald E; Steg, P Gabriel; Gershlick, Anthony H; Darius, Harald; Meredith, Ian T; Ormiston, John; Tanguay, Jean-François; Windecker, Stephan; Garratt, Kirk N; Kandzari, David E; Lee, David P; Simon, Daniel I; Iancu, Adrian Corneliu; Trebacz, Jaroslaw; Mauri, Laura

    2015-10-01

    This study sought to compare rates of stent thrombosis and major adverse cardiac and cerebrovascular events (MACCE) (composite of death, myocardial infarction, or stroke) after coronary stenting with drug-eluting stents (DES) versus bare-metal stents (BMS) in patients who participated in the DAPT (Dual Antiplatelet Therapy) study, an international multicenter randomized trial comparing 30 versus 12 months of dual antiplatelet therapy in subjects undergoing coronary stenting with either DES or BMS. Despite antirestenotic efficacy of coronary DES compared with BMS, the relative risk of stent thrombosis and adverse cardiovascular events is unclear. Many clinicians perceive BMS to be associated with fewer adverse ischemic events and to require shorter-duration dual antiplatelet therapy than DES. Prospective propensity-matched analysis of subjects enrolled into a randomized trial of dual antiplatelet therapy duration was performed. DES- and BMS-treated subjects were propensity-score matched in a many-to-one fashion. The study design was observational for all subjects 0 to 12 months following stenting. A subset of eligible subjects without major ischemic or bleeding events were randomized at 12 months to continued thienopyridine versus placebo; all subjects were followed through 33 months. Among 10,026 propensity-matched subjects, DES-treated subjects (n = 8,308) had a lower rate of stent thrombosis through 33 months compared with BMS-treated subjects (n = 1,718, 1.7% vs. 2.6%; weighted risk difference -1.1%, p = 0.01) and a noninferior rate of MACCE (11.4% vs. 13.2%, respectively, weighted risk difference -1.8%, p = 0.053, noninferiority p stent thrombosis that are lower than BMS-treated subjects. (The Dual Antiplatelet Therapy Study [DAPT study]; NCT00977938). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Outcome of everolimus eluting bioabsorbable vascular scaffold (BVS) compared to non BVS drug eluting stent in the management of ST-segment elevation myocardial infarction (STEMI) — A comparative study

    International Nuclear Information System (INIS)

    Chakraborty, Rabin; Patra, Soumya; Banerjee, Suvro; Pande, Arindam; Khan, Aftab; Mandol, Prakash Chandra; Ghosh, Debashish; De, Swapan Kumar; Das, Sankha Subhro; Nag, Raja

    2016-01-01

    Background: The safety and efficacy of everolimus eluting bioabsorbable vascular scaffold (BVS) in the management of “ST” segment elevation myocardial infarction (STEMI) are yet to be established. Aims: To evaluate immediate and short term safety and efficacy of the everolimus-eluting ABSORB BVS compared with non BVS drug eluting stent (DES) in patients with STEMI. Methods: From December 2013 to December 2014, 220 patients with STEMI were included in this study. Among them, 35 patients treated with BVS were compared with a control group composed of 180 patients who underwent non BVS DES implantation in the same time period. The incidence of major adverse cardiac events (MACE: stent thrombosis: death, non-fatal myocardial infarction, or target vessel/lesion revascularization) before discharge and up to six months was evaluated. Results: 1 vessel disease was more frequent whereas, 2 and 3 vessel disease was less frequent in BVS group. Procedural characteristics were also similar between groups, except for the use of post dilation (p = 0.04). Procedural success, in-hospital, and up to six-month MACE rates were similar between both groups. Definite or probable stent thrombosis did not occur (according to the ARC criteria) in BVS patients, though two patients during the index admission and another two patients in the first month after DES implantation had stent thrombosis. Conclusion: The use of the ABSORB BVS for STEMI is feasible and associated with good procedural safety, and angiographic success rate.

  8. Outcome of everolimus eluting bioabsorbable vascular scaffold (BVS) compared to non BVS drug eluting stent in the management of ST-segment elevation myocardial infarction (STEMI) — A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Rabin; Patra, Soumya, E-mail: dr_soumyapatra@rediffmail.com; Banerjee, Suvro; Pande, Arindam; Khan, Aftab; Mandol, Prakash Chandra; Ghosh, Debashish; De, Swapan Kumar; Das, Sankha Subhro; Nag, Raja

    2016-04-15

    Background: The safety and efficacy of everolimus eluting bioabsorbable vascular scaffold (BVS) in the management of “ST” segment elevation myocardial infarction (STEMI) are yet to be established. Aims: To evaluate immediate and short term safety and efficacy of the everolimus-eluting ABSORB BVS compared with non BVS drug eluting stent (DES) in patients with STEMI. Methods: From December 2013 to December 2014, 220 patients with STEMI were included in this study. Among them, 35 patients treated with BVS were compared with a control group composed of 180 patients who underwent non BVS DES implantation in the same time period. The incidence of major adverse cardiac events (MACE: stent thrombosis: death, non-fatal myocardial infarction, or target vessel/lesion revascularization) before discharge and up to six months was evaluated. Results: 1 vessel disease was more frequent whereas, 2 and 3 vessel disease was less frequent in BVS group. Procedural characteristics were also similar between groups, except for the use of post dilation (p = 0.04). Procedural success, in-hospital, and up to six-month MACE rates were similar between both groups. Definite or probable stent thrombosis did not occur (according to the ARC criteria) in BVS patients, though two patients during the index admission and another two patients in the first month after DES implantation had stent thrombosis. Conclusion: The use of the ABSORB BVS for STEMI is feasible and associated with good procedural safety, and angiographic success rate.

  9. Chronic Kidney Disease in the Second-Generation Drug-Eluting Stent Era: Pooled Analysis of the Korean Multicenter Drug-Eluting Stent Registry.

    Science.gov (United States)

    Lee, Joo Myung; Kang, Jeehoon; Lee, Euijae; Hwang, Doyeon; Rhee, Tae-Min; Park, Jonghanne; Kim, Hack-Lyoung; Lee, Sang Eun; Han, Jung-Kyu; Yang, Han-Mo; Park, Kyung Woo; Na, Sang-Hoon; Kang, Hyun-Jae; Koo, Bon-Kwon; Kim, Hyo-Soo

    2016-10-24

    The purpose of this study was to evaluate the clinical impact of chronic kidney disease (CKD) on clinical outcomes in contemporary practice of percutaneous coronary intervention (PCI) using second-generation drug-eluting stents (DES). Although second-generation DES have improved the safety and efficacy issues in PCI, data regarding the performance of second-generation DES in patients with CKD are still limited. We performed a patient-level pooled analysis on 12,426 patients undergoing PCI using second-generation DES from the Korean Multicenter Drug-Eluting Stent Registry. Endpoints were stent-oriented outcomes (target lesion failure [TLF]) and patient-oriented composite outcomes (POCO) during a median follow-up of 35 months. CKD patients were stratified by the estimated glomerular filtration rate (eGFR) from mild CKD to end-stage renal disease patients, and by the coexistence of diabetes mellitus (DM). A total of 2,927 patients had CKD (23.6%), who showed a significantly higher risk of TLF (adjusted hazard ratio [HR adjust ]: 1.50; 95% confidence interval [CI]: 1.21 to 1.86) and POCO (HR adjust 1.34; 95% CI: 1.17 to 1.55) compared to patients with preserved renal function. Stratified analysis by eGFR showed that TLF was not increased in the mild to moderate CKD, whereas severe CKD and dialysis-dependent patients showed significantly higher risk of TLF (HR adjust 2.44; 95% CI: 1.54 to 3.86; HR adjust 3.58; 95% CI: 2.52 to 5.08, respectively). The eGFR threshold of increased clinical events was 40 to 45 ml/min/1.73 m 2 . Among CKD patients, DM CKD patients showed a higher incidence of TLF compared to non-DM CKD patients (HR adjust : 1.82; 95% CI: 1.32 to 2.52), driven by the increase in target vessel-related events. In the era of second-generation DES, CKD patients were at a significantly higher risk of clinical outcomes only in severe CKD and end-stage renal disease patients. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All

  10. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    International Nuclear Information System (INIS)

    De Cock, Erwin; Sapoval, Marc; Julia, Pierre; Lissovoy, Greg de; Lopes, Sandra

    2013-01-01

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of €6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  11. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    Energy Technology Data Exchange (ETDEWEB)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com [United BioSource Corporation, Peri- and Post-Approval Services (Spain); Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Department of Cardiovascular and Interventional Radiology (France); Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Cardiovascular Surgery Department (France); Lissovoy, Greg de, E-mail: gdelisso@jhsph.edu [Johns Hopkins Bloomberg School of Public Health, Department of Health Policy and Management (United States); Lopes, Sandra, E-mail: Sandra.Lopes@CookMedical.com [Cook Medical, Health Economics and Reimbursement (Denmark)

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  12. Comparison of clinical outcomes after drug-eluting balloon and drug-eluting stent use for in-stent restenosis related acute myocardial infarction: a retrospective study

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Fang

    2018-04-01

    Full Text Available Background Good results of drug-eluting balloon (DEB use are achieved in in-stent restenosis (ISR lesions, small vessel disease, long lesions, and bifurcations. However, few reports exist about DEB use in acute myocardial infarction (AMI with ISR. This study’s aim was to evaluate the efficacy of DEB for AMI with ISR. Methods Between November 2011 and December 2015, 117 consecutive patients experienced AMI including ST-segment elevation MI, and non-ST-segment elevation MI due to ISR, and received percutaneous coronary intervention (PCI. We divided our patients into two groups: (1 PCI with further DEB, and (2 PCI with further drug-eluting stent (DES. Clinical outcomes such as target lesion revascularization, target vessel revascularization, recurrent MI, stroke, cardiovascular mortality, and all-cause mortality were analyzed. Results The patients’ average age was 68.37 ± 11.41 years; 69.2% were male. A total of 75 patients were enrolled in the DEB group, and 42 patients were enrolled in the DES group. The baseline characteristics between the two groups were the same without statistical differences except for gender. Peak levels of cardiac biomarker, pre- and post-PCI cardiac function were similar between two groups. The major adverse cardiac cerebral events rate (34.0% vs. 35.7%; p = 0.688 and cardiovascular mortality rate (11.7% vs. 12.8%; p = 1.000 were similar in both groups. Conclusions DEB is a reasonable strategy for AMI with ISR. Compared with DES, DEB is an alternative strategy which yielded acceptable short-term outcomes and similar 1-year clinical outcomes.

  13. Long-Term Follow-up of the PADI Trial : Percutaneous Transluminal Angioplasty Versus Drug-Eluting Stents for Infrapopliteal Lesions in Critical Limb Ischemia

    NARCIS (Netherlands)

    Spreen, Marlon I; Martens, Jasper M; Knippenberg, Bob; van Dijk, Lukas C; De Vries, Jean-Paul P. M.; Vos, Jan Albert; de Borst, Gert Jan; Vonken, Evert-Jan P A; Bijlstra, Okker D; Wever, Jan J; Statius van Eps, Randolph G; Mali, Willem P Th M; van Overhagen, Hendrik

    2017-01-01

    BACKGROUND: Clinical outcomes reported after treatment of infrapopliteal lesions with drug-eluting stents (DESs) have been more favorable compared with percutaneous transluminal angioplasty with a bailout bare metal stent (PTA-BMS) through midterm follow-up in patients with critical limb ischemia.

  14. Drug-eluting stent thrombosis: results from the multicenter Spanish registry ESTROFA (Estudio ESpañol sobre TROmbosis de stents FArmacoactivos).

    Science.gov (United States)

    de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa

    2008-03-11

    This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.

  15. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

    Science.gov (United States)

    Kim, Jung-Sun; Ha, Jinyong; Kim, Byeong-Keuk; Shin, Dong-Ho; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki

    2014-06-01

    This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. Tracking the fate of interested regions of struts at different time points has not been investigated. Post-intervention and 6-month follow-up optical coherence tomographic evaluations were performed in 82 patients treated with biolimus- (n = 37) or sirolimus-eluting stents (n = 45). Post-stent apposition was classified as embedded, apposed, or malapposed. For volumetric stent evaluation, the post-intervention strut-artery distance and the neointimal thickness at follow-up were measured as a function of the circumferential arc length and longitudinal stent length. Computer-generated contour plots of the strut-artery distance and neointimal thickness were compared. The percentages of embedded and malapposed struts after intervention were 1.8% (Interquartile range [IQR]: 0.6% to 6.2%) and 2.3% (IQR: 0.5% to 5.2%), respectively. The percentages of uncovered and malapposed struts at 6 months were 16.0% (IQR: 7.4% to 33.3%) and 0% (IQR: 0% to 0.7%), respectively. The percentage of uncovered struts at 6 months varied significantly with post-stent strut apposition (0% [IQR: 0% to 11.4%] in embedded, 16.3% [IQR: 8.1% to 31.3%] in apposed, and 26.8% [IQR: 0% to 56.3%] in malapposed, p < 0.001 for all pairwise comparisons). In lesions without tissue prolapse, embedded struts were all covered (100% covered struts) compared with those with tissue prolapse (76.8% covered, p < 0.001). The optical coherence tomography-guided optimization of stent strut apposition enhances strut coverage at follow-up. This comprehensive method for evaluating strut apposition may provide more useful information to understanding the serial changes in strut coverage. (Neointimal Coverage After Implantation of Biolimus Eluting Stent With Biodegradable Polymer: Optical Coherence Tomographic Assessment According to the Treatment of

  16. Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)

    NARCIS (Netherlands)

    A.J.J. IJsselmuiden (Alexander); C. Simsek (Cihan); Van Driel, A.G. (A. G.); Bouchez, D. (D.); G. Amoroso (Giovanni); P. Vermeersch (Paul); Karjalainen, P.P. (P. P.)

    2018-01-01

    textabstractAims To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs). Methods and Results A randomised controlled trial was performed in four hospitals in three European countries between

  17. In-Stent Restenosis of Drug-Eluting Stents Compared With a Matched Group of Patients With De Novo Coronary Artery Stenosis.

    Science.gov (United States)

    Buchanan, Kyle D; Torguson, Rebecca; Rogers, Toby; Xu, Linzhi; Gai, Jiaxiang; Ben-Dor, Itsik; Suddath, William O; Satler, Lowell F; Waksman, Ron

    2018-03-13

    Drug-eluting stents (DES) significantly reduced the incidence of in-stent restenosis (ISR). However, ISR still exists in the contemporary DES era. Previously deemed to be a benign process, ISR leads to complex presentation and intervention. This study aimed to compare the presentation and outcome of DES-ISR versus de novo lesions. We performed a retrospective analysis of 11,666 patients receiving percutaneous coronary intervention from 2003 to 2017 and divided them into 2 groups by de novo stenosis and ISR. They were matched based on common cardiovascular risk factors at a 4:1 ratio, respectively. After matching, a total of 1,888 patients with 3,126 de novo lesions and 472 patients with 508 ISR lesions were analyzed. Patients with ISR presented more often with unstable angina (61% vs 45%, p stent technique and should motivate the continued development of fully bioresorbable scaffolds. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  19. Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome trial.

    Science.gov (United States)

    Kaiser, Christoph; Galatius, Soeren; Jeger, Raban; Gilgen, Nicole; Skov Jensen, Jan; Naber, Christoph; Alber, Hannes; Wanitschek, Maria; Eberli, Franz; Kurz, David J; Pedrazzini, Giovanni; Moccetti, Tiziano; Rickli, Hans; Weilenmann, Daniel; Vuillomenet, André; Steiner, Martin; Von Felten, Stefanie; Vogt, Deborah R; Wadt Hansen, Kim; Rickenbacher, Peter; Conen, David; Müller, Christian; Buser, Peter; Hoffmann, Andreas; Pfisterer, Matthias

    2015-01-06

    Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. © 2014 American Heart Association, Inc.

  20. Impaired health status in Type D patients following PCI in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Denollet, Johan; Ong, Andrew T L

    2007-01-01

    Drug-eluting stenting reduces restenosis post-percutaneous coronary intervention (PCI), but subgroups of patients may not benefit optimally from this procedure. We examined the impact of Type D personality on health status over time and the clinical relevance of Type D as a predictor of impaired...... health status at 12 months in unselected post-PCI patients....

  1. Zotarolimus-eluting Resolute Integrity versus everolimus-eluting Xience Xpedition stents in the management of very long (>30 mm) de novo coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Patra, Soumya, E-mail: dr_soumyapatra@rediffmail.com; Chakraborty, Rabindra Nath; Pande, Arindam; Banerjee, Suvro; Jena, Manabhanjan; Mandal, Prakash Chandra; De, Swapan Kumar; Khan, Aftab; Das, Sankha Suvro; Ghosh, Debashish; Nag, Raja

    2017-04-15

    Background: Procedural and clinical outcomes in patients with very long (>30 mm) coronary lesions who underwent stent-based percutaneous coronary interventions are still unfavorable. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and Xpedition everolimus-eluting stents (X-EES) for patients with de novo very long coronary lesions. Methods: This comparative single-centre, retrospective study compared long R-ZES and X-EES in consecutive patients admitted with very long (≥30 mm) native ACC/AHA type C coronary lesions in 2014. All patients were followed up clinically at 1, 3, 6 and 12 months. In this study, only symptom-driven angiogram was advised. The study end point was to evaluate immediate procedural success and one-year rate of target lesion failure (TLF), which is a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization (TLR). Results: Total number of patients enrolled in this study was 185 (R-ZES = 107; X-EES = 78). The baseline characteristics and post procedural success rate were similar between R-ZES and X-EES groups, including the post stenting lesion lengths (36.6 ± 1.92 mm vs 40.71 ± 6.175 mm, P = 0.09). At 12-month follow-up, there were no significant between-group differences in the rate of adverse clinical events (death, myocardial infarction, stent thrombosis, target lesion revascularization, and composite outcomes). Procedural success was achieved in 94% in R-ZES group and 93% in X-EES group (P = 0.24). The incidence of TLF was 5% in R-ZES and 4% in X-EES groups (HR-1.25; 95% CI-0.86-5.6; P = 0.19). Conclusion: Patients with de novo long coronary artery disease, R-ZES implantation showed similar clinical outcome as compared with X-EES implantation. - Highlights: • This is the first study comparing between R-ZES (Resolute Integrity) and X-EES (Xience Xpedition) used in PCI for long coronary artery disease. Here, single stent length of more than 30

  2. A Novel Stent Coated with Antibodies to Endoglin Inhibits Neointimal Formation of Porcine Coronary Arteries

    Directory of Open Access Journals (Sweden)

    Song Cui

    2014-01-01

    Full Text Available Endoglin/CD105 is an accessory protein of the transforming growth factor-β receptor system that plays a critical role in proliferation of endothelial cells and neovasculature. Here, we aimed to assess the effect of novel stents coated with antibodies to endoglin (ENDs on coronary neointima formation. Thirty ENDs, thirty sirolimus-eluting stents (SESs, and thirty bare metal stents (BMSs were randomly assigned and placed in the coronary arteries in 30 juvenile pigs. Histomorphometric analysis and scanning electron microscopy were performed after stent implantation. Our results showed that after 7 days, there was no difference in the neointimal area and percent area stenosis in ENDs compared with SMSs or BMSs. After 14 days, the neointima area and percent area stenosis in ENDs were markedly decreased than those in BMSs or SESs (P<0.05. Moreover, the percentage of reendothelialization was significantly higher in ENDs than that in SESs or BMSs (P<0.01 at 7 and 14 days. The artery injury and the inflammation scores were similar in all groups at 7 and 14 days. In conclusion, our results demonstrated for the first time to our knowledge that endoglin antibody-coated stents can markedly reduce restenosis by enhancing reendothelialization in the porcine model and potentially offer a new approach to prevent restenosis.

  3. Drug-eluting stents appear superior to bare metal stents for vein-graft PCI in vessels up to a stent diameter of 4 mm

    Directory of Open Access Journals (Sweden)

    Oliver P. Guttmann

    2016-05-01

    Full Text Available BackgroundResearch trials have shown improved short-term outcome with drug-eluting stents (DES over bare metal stents (BMS in saphenous vein graft (SVG percutaneous coronary intervention (PCI, primarily by reducing target vessel revascularization (TVR for in-stent restenosis. We compared the outcomes in patients undergoing SVG stent implantation treated with DES or BMS. In exploratory analyses we investigated the influence of stent generation and diameter.MethodsData were obtained from a prospective database of 657 patients who underwent PCI for SVG lesions between 2003 and 2011. A total of 344 patients had PCI with BMS and 313 with DES. Propensity scores were developed based on 15 observed baseline covariates in a logistic regression model with stent type as the dependent variable. The nearest-neighbour-matching algorithm with Greedy 5-1 Digit Matching was used to produce two patient cohorts of 313 patients each. We assessed major adverse cardiac events (MACE out to a median of 3.3 years (interquartile range: 2.1-4.1. MACE was defined as all-cause mortality, myocardial infarction (MI, TVR and stroke.ResultsThere was a significant difference in MACE between the two groups in favour of DES (17.9% DES vs. 31.2% BMS group; p = 0.0017 over the 5-year follow-up period. MACE was driven by increased TVR in the BMS group. There was no difference in death, MI or stroke. Adjusted Cox analysis confirmed a decreased risk of MACE for DES compared with BMS 0.75 (95% confidence interval (CI 0.52-0.94, with no difference in the hazard of all-cause mortality (hazard ratio: 1.08; 95% CI: 0.77-1.68. However, when looking at stent diameters greater than 4 mm, no difference was seen in MACE rates between BMS and DES.ConclusionsOverall in our cohort of patients who had PCI for SVG disease, DES use resulted in lower MACE rates compared with BMS over a 5-year follow-up period; however, for stent diameters over 4 mm no difference in MACE rates was seen.

  4. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Radu, Maria D; Räber, Lorenz; Heo, Jungho

    2014-01-01

    history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. METHODS...

  5. Bioresorbable polymer coated drug eluting stent: a model study.

    Science.gov (United States)

    Rossi, Filippo; Casalini, Tommaso; Raffa, Edoardo; Masi, Maurizio; Perale, Giuseppe

    2012-07-02

    In drug eluting stent technologies, an increased demand for better control, higher reliability, and enhanced performances of drug delivery systems emerged in the last years and thus offered the opportunity to introduce model-based approaches aimed to overcome the remarkable limits of trial-and-error methods. In this context a mathematical model was studied, based on detailed conservation equations and taking into account the main physical-chemical mechanisms involved in polymeric coating degradation, drug release, and restenosis inhibition. It allowed highlighting the interdependence between factors affecting each of these phenomena and, in particular, the influence of stent design parameters on drug antirestenotic efficacy. Therefore, the here-proposed model is aimed to simulate the diffusional release, for both in vitro and the in vivo conditions: results were verified against various literature data, confirming the reliability of the parameter estimation procedure. The hierarchical structure of this model also allows easily modifying the set of equations describing restenosis evolution to enhance model reliability and taking advantage of the deep understanding of physiological mechanisms governing the different stages of smooth muscle cell growth and proliferation. In addition, thanks to its simplicity and to the very low system requirements and central processing unit (CPU) time, our model allows obtaining immediate views of system behavior.

  6. Evaluation of XIENCE V everolimus-eluting and Taxus Express2 paclitaxel-eluting coronary stents in patients with jailed side branches from the SPIRIT IV trial at 2 years.

    Science.gov (United States)

    Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W

    2013-06-01

    The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All

  7. Magmaris: a new generation metallic sirolimus-eluting fully bioresorbable scaffold: present status and future perspectives.

    Science.gov (United States)

    Rapetto, Claudio; Leoncini, Massimo

    2017-08-01

    Drug-eluting stents (DES) have reached a high safety and efficacy profile, becoming the best option for percutaneous coronary interventions (PCI) based revascularization. However, despite their optimal performance, a few concerns remain regarding their use, mainly due to permanent caging of the vessels and its consequences, first of all late stent thrombosis (ST). Bioresorbable scaffolds (BRS) aim to overcome these issues. The results achieved in randomized controlled trials (RCT) by the first generation of poly-L-lactic acid (PLLA) based scaffolds were promising at 1 year, but the first long term reports (albeit flawed by non-optimal implantation technique) have been disappointing, showing, for instance, an increased risk of ST and target vessel myocardial infarction (TV-MI). In such a scenario the advent of a newer generation magnesium (Mg) based BRS is welcome, mainly because of its innovative mechanical and chemical features coupled with well proven biocompatibility. Despite being in its infancy, this technology seems to promise a great potential. In our article, we review the Magmaris (Biotronik AG, Bülach, Switzerland) Mg BRS development from animal models to human use, underscore its best qualities and weaknesses, and provide hints of its possible future perspectives.

  8. Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents

    DEFF Research Database (Denmark)

    Giustino, Gennaro; Mastoris, Ioannis; Baber, Usman

    2016-01-01

    OBJECTIVES: The aim of this study was to investigate the clinical correlates and prognostic impact of coronary artery calcification (CAC) in women undergoing percutaneous coronary intervention with drug-eluting stents (DES). BACKGROUND: The clinical correlates and the prognostic significance of CAC...

  9. [Experience with the use of the bio-active stent coated with titanium nitric oxide compared with zotarolimus-eluting stent: experience of a unit medical high specialty].

    Science.gov (United States)

    Garcia-Gutierrez, Juan C; Palacios-Rodríguez, Juan M; Cordova-Correa, Horacio G; Becerra-Laguna, Carlos A; López-López, Hugo A; Salinas Aragón, Miguel A; García-Bonilla, Jorge

    2016-01-01

    The use of coronary stents in coronary angioplasty has evolved dramatically in its design, type materials, polymers, and a variety of drugs, the use of coronary stents covered nitric oxide have shown satisfactory results in practice, however compared to the results reported drug-eluting stents, there is little information. The aim of this study was to compare clinical outcomes of a stainless steel stent Bioactive nitric oxide coated titanium (BAS) and a drug-eluting stent zotarolimus (DES) in daily clinical practice. A retrospective, analytical, descriptive and comparative study aimed at evaluating the safety and efficacy of two devices with different characteristics in our population. The primary endpoints were: death, acute infarction (AMI), and re intervention injury Treated (RLT). A total of 759 patients were included in the study which was performed angioplasty to a single vessel. Were divided into two arms 382 with DES and 377 patients with BAS, the one year follow up was carried in 95%. After this follow-up period, primary points (cardiovascular death, myocardial infarction, TLR and stent thrombosis) for arm DES vs BAS; 9.5% vs 8.5% P=NS but with shorter periods of dual antiplatelet therapy for arm BAS 6.9±4.1 vs 11.1±2.5 months DES P=.0001. The results were independent of the clinical syndrome of presentation. After one year of follow no statistically significant difference in major clinical events, there was a trend in favour of BAS vs SM with respect to revascularization of the target lesion without reaching statistical significance. Copyright © 2015 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  10. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    Energy Technology Data Exchange (ETDEWEB)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de; Kurre, Wiebke, E-mail: w.kurre@klinikum-stuttgart.de [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany); Schmid, Elisabeth, E-mail: ESchmid@klinikum-stuttgart.de; Baezner, Hansjoerg, E-mail: H.Baezner@klinikum-stuttgart.de [Klinikum Stuttgart, Klinik fuer Neurologie, Neurozentrum (Germany); Henkes, Hans, E-mail: hhhenkes@aol.com [Klinikum Stuttgart, Katharinenhospital, Klinik fuer Neuroradiologie, Neurozentrum (Germany)

    2013-04-15

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  11. Ultra-hydrophilic stent platforms promote early vascular healing and minimise late tissue response: a potential alternative to second-generation drug-eluting stents.

    Science.gov (United States)

    Kolandaivelu, Kumaran; Bailey, Lynn; Buzzi, Stefano; Zucker, Arik; Milleret, Vincent; Ziogas, Algirdas; Ehrbar, Martin; Khattab, Ahmed A; Stanley, James R L; Wong, Gee K; Zani, Brett; Markham, Peter M; Tzafriri, Abraham R; Bhatt, Deepak L; Edelman, Elazer R

    2017-04-20

    Simple surface modifications can enhance coronary stent performance. Ultra-hydrophilic surface (UHS) treatment of contemporary bare metal stents (BMS) was assessed in vivo to verify whether such stents can provide long-term efficacy comparable to second-generation drug-eluting stents (DES) while promoting healing comparably to BMS. UHS-treated BMS, untreated BMS and corresponding DES were tested for three commercial platforms. A thirty-day and a 90-day porcine coronary model were used to characterise late tissue response. Three-day porcine coronary and seven-day rabbit iliac models were used for early healing assessment. In porcine coronary arteries, hydrophilic treatment reduced intimal hyperplasia relative to the BMS and corresponding DES platforms (1.5-fold to threefold reduction in 30-day angiographic and histological stenosis; p<0.04). Endothelialisation was similar on UHS-treated BMS and untreated BMS, both in swine and rabbit models, and lower on DES. Elevation in thrombotic indices was infrequent (never observed with UHS, rare with BMS, most often with DES), but, when present, correlated with reduced endothelialisation (p<0.01). Ultra-hydrophilic surface treatment of contemporary stents conferred good healing while moderating neointimal and thrombotic responses. Such surfaces may offer safe alternatives to DES, particularly when rapid healing and short dual antiplatelet therapy (DAPT) are crucial.

  12. Cost-effectiveness of drug-eluting stents versus bare-metal stents in patients undergoing percutaneous coronary intervention.

    Science.gov (United States)

    Baschet, Louise; Bourguignon, Sandrine; Marque, Sébastien; Durand-Zaleski, Isabelle; Teiger, Emmanuel; Wilquin, Fanny; Levesque, Karine

    2016-01-01

    To determine the cost-effectiveness of drug-eluting stents (DES) compared with bare-metal stents (BMS) in patients requiring a percutaneous coronary intervention in France, using a recent meta-analysis including second-generation DES. A cost-effectiveness analysis was performed in the French National Health Insurance setting. Effectiveness settings were taken from a meta-analysis of 117 762 patient-years with 76 randomised trials. The main effectiveness criterion was major cardiac event-free survival. Effectiveness and costs were modelled over a 5-year horizon using a three-state Markov model. Incremental cost-effectiveness ratios and a cost-effectiveness acceptability curve were calculated for a range of thresholds for willingness to pay per year without major cardiac event gain. Deterministic and probabilistic sensitivity analyses were performed. Base case results demonstrated that DES are dominant over BMS, with an increase in event-free survival and a cost-reduction of €184, primarily due to a diminution of second revascularisations, and an absence of myocardial infarction and stent thrombosis. These results are robust for uncertainty on one-way deterministic and probabilistic sensitivity analyses. Using a cost-effectiveness threshold of €7000 per major cardiac event-free year gained, DES has a >95% probability of being cost-effective versus BMS. Following DES price decrease, new-generation DES development and taking into account recent meta-analyses results, the DES can now be considered cost-effective regardless of selective indication in France, according to European recommendations.

  13. In Vivo and In Vitro Elution of Analgesics from Multilayered Poly(D,L)-lactide-co-glycolide Nanofibers Incorporated Ureteral Stents

    OpenAIRE

    Lin, Yi-Chia; Liu, Kuo-Sheng; Lee, Demei; Li, Min-Jhan; Liu, Shih-Jung; Ito, Hiroshi

    2018-01-01

    We develop novel analgesic-eluting nanofiber-incorporated ureteral stents that offer sustained release of lidocaine and ketorolac for local drug delivery. Lidocaine and poly(D,L)-lactide-co-glycolide (PLGA) were dissolved in hexafluoroisopropanol and were electrospun into nonwoven nanofibers onto the surface of ureteral stents. This was followed by electrospinning of another layer of PLGA nanofibers containing ketorolac. Electrospun drug-loaded nanofibers were then characterized using scannin...

  14. Comparison of zotarolimus-eluting and everolimus-eluting coronary stents

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Silber, Sigmund; Garg, Scot

    2010-01-01

    New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed...

  15. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    Science.gov (United States)

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion

  16. Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

    International Nuclear Information System (INIS)

    Vajda, Zsolt; Güthe, Thomas; Perez, Marta Aguilar; Kurre, Wiebke; Schmid, Elisabeth; Bäzner, Hansjörg; Henkes, Hans

    2013-01-01

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54–86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

  17. Optical coherence tomography findings after chronic total occlusion interventions: Insights from the “AngiographiC evaluation of the everolimus-eluting stent in chronic Total occlusions” (ACE-CTO) study (NCT01012869)

    Energy Technology Data Exchange (ETDEWEB)

    Sherbet, Daniel P.; Christopoulos, Georgios; Karatasakis, Aris; Danek, Barbara Anna; Kotsia, Anna; Navara, Rachita; Michael, Tesfaldet T.; Roesle, Michele; Rangan, Bavana V.; Haagen, Donald [VA North Texas Healthcare System and University of Texas Southwestern Medical Center, Dallas, TX (United States); Garcia, Santiago [Minneapolis VA Healthcare System and University of Minnesota, Minneapolis, MN (United States); Maniu, Calin [Bon Secours Health System, Suffolk, VA (United States); Pershad, Ashish [Banner Good Samaritan Medical Center, Phoenix, AZ (United States); Abdullah, Shuaib M.; Hastings, Jeffrey L.; Kumbhani, Dharam J.; Luna, Michael; Addo, Tayo; Banerjee, Subhash [VA North Texas Healthcare System and University of Texas Southwestern Medical Center, Dallas, TX (United States); Brilakis, Emmanouil S., E-mail: esbrilakis@gmail.com [VA North Texas Healthcare System and University of Texas Southwestern Medical Center, Dallas, TX (United States)

    2016-10-15

    Background: There is limited information on optical coherence tomography (OCT) findings after percutaneous coronary intervention (PCI) of chronic total occlusions (CTOs). OCT allows high resolution imaging that can enhance understanding of the vascular response after stenting of chronically occluded vessels. Methods: The Angiographic Evaluation of the Everolimus-Eluting Stent in Chronic Total Occlusions (ACE-CTO) study collected angiographic and clinical outcomes from 100 patients undergoing CTO PCI with the everolimus-eluting stent (EES). OCT was performed 8-months post stenting in 62 patients. Every third frame was analyzed throughout the course of the stented arterial segment. Lumen contours were semi-automatically traced and stent struts were manually delineated, with automatic measurement of the strut to lumen distance. Struts on the luminal side of the lumen contour were classified as malapposed if the distance to the lumen contour exceeded 0.108 mm. Results: A total of 44,450 struts in 6047 frames were analyzed, of which 4113 9.3%, 95% confidence intervals [CI] 9.0% to 9.5%) were malapposed and 1230 (2.8%, 95% CI 2.6% to 2.9%) were uncovered. Fifty-five of 62 patients (88.7%, 95% CI 78.5% to 98.4%) had at least one malapposed stent strut and 50 patients (80.7%, 95% CI 69.2% to 88.6%) had at least one uncovered stent strut. Mean strut-intimal thickness of the apposed and malapposed struts was 0.126 ± 0.140 mm and − 0.491 ± 0.440 mm, respectively. Conclusion: High rates of stent strut malapposition and incomplete stent strut coverage were observed after CTO PCI using EES, highlighting unique challenges associated with stent implantation in CTOs. - Highlights: • Percutaneous coronary intervention with drug-eluting stents for chronic total occlusion is associated with a 40% rate of binary in-stent restenosis at 8 months • Of patients who receive a drug eluting stent for a chronic total occlusion 88.7% will have stent strut malapposition and 80.7% will

  18. IVUS Findings in Late and Very Late Stent Thrombosis. A Comparison Between Bare-metal and Drug-eluting Stents.

    Science.gov (United States)

    Fuentes, Lara; Gómez-Lara, Josep; Salvatella, Neus; Gonzalo, Nieves; Hernández-Hernández, Felipe; Fernández-Nofrerias, Eduard; Sánchez-Recalde, Ángel; Alfonso, Fernando; Romaguera, Rafael; Ferreiro, José Luis; Roura, Gerard; Teruel, Luis; Gracida, Montserrat; Marcano, Ana Lucrecia; Gómez-Hospital, Joan-Antoni; Cequier, Ángel

    2018-05-01

    Stent thrombosis (ST) is a life-threatening complication after stent implantation. Intravascular ultrasound is able to discern most causes of ST. The aim of this study was to compare intravascular ultrasound findings between bare-metal stents (BMS) and drug-eluting stents (DES) in patients with late (31 days to 1 year) or very late ST (> 1 year). Of 250 consecutive patients with late or very late ST in 7 Spanish institutions, 114 patients (45.5% BMS and 54.5% DES) were imaged with intravascular ultrasound. Off-line intravascular ultrasound analysis was performed to assess malapposition, underexpansion, and neoatherosclerosis. The median time from stent implantation to ST was 4.0 years with BMS and 3.4 years with DES (P = .04). Isolated malapposition was similarly observed in both groups (36.5% vs 46.8%; P = .18) but was numerically lower with BMS (26.6% vs 48.0%; P = .07) in patients with very late ST. Isolated underexpansion was similarly observed in both groups (13.5% vs 11.3%; P = .47). Isolated neoatherosclerosis occurred only in patients with very late ST and was more prevalent with BMS (22.9%) than with DES (6.0%); P = .02. At 2.9 years' follow-up, there were 0% and 6.9% cardiac deaths, respectively (P = .06) and recurrent ST occurred in 4.0% and 5.2% of patients, respectively (P = .60). Malapposition was the most common finding in patients with late and very late ST and is more prevalent with DES in very late ST. In contrast, neoatherosclerosis was exclusively observed in patients with very late ST and mainly with BMS. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  19. TIDES-ACS Trial: comparison of titanium-nitride-oxide coated bio-active-stent to the drug (everolimus)-eluting stent in acute coronary syndrome. Study design and objectives.

    Science.gov (United States)

    Colkesen, E B; Eefting, F D; Rensing, B J; Suttorp, M J; Ten Berg, J M; Karjalainen, P P; Van Der Heyden, J A

    2015-02-01

    Drug-eluting stents (DES), delivering antiproliferative drugs from a durable polymer, have shown to reduce in-stent restenosis after percutaneous coronary intervention (PCI) compared to bare-metal stents (BMS). However, they have been associated with a hypersensitivity reaction, delayed healing, and incomplete endothelialization, which may contribute to an increased risk of late stent thrombosis. Consequently, a prolonged duration of dual antiplatelet therapy (DAPT) is needed, with an increased risk of bleeding complication. A number of stent technologies are being developed in an attempt to modify late thrombotic events and DAPT duration. The Optimax™ stent is such a novel, next generation bioactive stent (BAS), in which a thicker layer of titanium-nitride-oxide coating is inserted over the stent struts. The rationale of this is to obtain more efficient and rapid vascular healing at the site of the stent implantation. The aim of TIDES-ACS Trial is to compare clinical outcome in patients presenting with ACS, treated with PCI using Optimax-BAS versus Synergy™-EES. Second objective is to explore whether the Optimax™-BAS use is superior compared with Synergy™-EES use with respect of hard end points (cardiac death, myocardial infarction [MI] and major bleeding). A prospective, randomized, multicenter trial (ClinicalTrials.gov Identifier: NCT02049229), will be conducted in interventional centres in Finland (six centres), France (five centres) and Holland (two centres), including a total of 1800 patients.

  20. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1-year analysis of clinical and procedural secondary outcomes from a randomised controlled trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Chevalier, Bernard; Dudek, Dariusz; Cequier, Angel; Carrié, Didier; Iniguez, Andres; Dominici, Marcello; van der Schaaf, René J.; Haude, Michael; Wasungu, Luc; Veldhof, Susan; Peng, Lei; Staehr, Peter; Grundeken, Maik J.; Ishibashi, Yuki; Garcia-Garcia, Hector M.; Onuma, Yoshinobu

    2015-01-01

    Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an

  1. Cost-effectiveness analysis of biodegradable polymer versus durable polymer drug-eluting stents incorporating real-world evidence.

    Science.gov (United States)

    Teng, Monica; Zhao, Ying Jiao; Khoo, Ai Leng; Ananthakrishna, Rajiv; Yeo, Tiong Cheng; Lim, Boon Peng; Chan, Mark Y; Loh, Joshua P

    2018-06-05

    Compared with second-generation durable polymer drug-eluting stents (DP-DES), the cost-effectiveness of biodegradable polymer drug-eluting stents (BP-DES) remains unclear in the real-world setting. We assessed the cost-effectiveness of BP-DES in patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We developed a decision-analytic model to compare the cost-effectiveness of BP-DES to DP-DES over one year and five years from healthcare payer perspective. Relative treatment effects during the first year post-PCI were obtained from a real-world population analysis while clinical event risks in the subsequent four years were derived from a meta-analysis of published studies. At one year, based on the clinical data analysis of 497 propensity-score matched pairs of patients, BP-DES were associated with an incremental cost-effectiveness ratio (ICER) of USD20,503 per quality-adjusted life-year (QALY) gained. At five years, BP-DES yielded an ICER of USD4,062 per QALY gained. At the willingness-to-pay threshold of USD50,400 (one gross domestic product per capita in Singapore in 2015), BP-DES were cost-effective. Sensitivity analysis showed that the cost of stents had a significant impact on the cost-effectiveness of BP-DES. Threshold analysis demonstrated that if the cost difference between BP-DES and DP-DES exceeded USD493, BP-DES would not be cost-effective in patients with one-year of follow-up. BP-DES were cost-effective compared with DP-DES in patients with coronary artery disease at one year and five years after PCI. It is worth noting that the cost of stents had a significant impact on the findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Veres, M.; Tóth, S.; Koós, M. [Research Institute for Solid State Physics and Optics, Budapest (Hungary); Beiler, B. [Institute of Isotopes, HAS, Budapest (Hungary)

    2009-07-01

    Drug-eluting stents have several advantages over bare metal implants. They eliminate restenosis, the main drawback of bare metal stents. In addition the locally delivered drug is more effective and causes less side-effects. However in some cases dangerous stent thrombosis, inflammatory and allergy reactions were observed after their implantation, which first of all related to the drug-eluting coating. This project is aimed to develop a novel biocompatible nanoporous polymer layer by radiation induced polymerization that is capable of holding and eluting drugs and promotes endothelization after the release of the drug. (author)

  3. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    International Nuclear Information System (INIS)

    Veres, M.; Tóth, S.; Koós, M.; Beiler, B.

    2009-01-01

    Drug-eluting stents have several advantages over bare metal implants. They eliminate restenosis, the main drawback of bare metal stents. In addition the locally delivered drug is more effective and causes less side-effects. However in some cases dangerous stent thrombosis, inflammatory and allergy reactions were observed after their implantation, which first of all related to the drug-eluting coating. This project is aimed to develop a novel biocompatible nanoporous polymer layer by radiation induced polymerization that is capable of holding and eluting drugs and promotes endothelization after the release of the drug. (author)

  4. Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent

    DEFF Research Database (Denmark)

    Ishibashi, Yuki; Muramatsu, Takashi; Nakatani, Shimpei

    2015-01-01

    OBJECTIVES: This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. BACKGROUND: A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence...

  5. Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Korea University Guro Hospital, Seoul (Korea, Republic of); Oh, Joo Hyeogn; Park, Young Koo [Kyung Hee University Hospital, Seoul (Korea, Republic of); Song, Ho Young [University of Ulsan, College of Medicine, Seoul (Korea, Republic of); Park, Sang Joon [Hallym University, College of Medicine, Seoul (Korea, Republic of); Yuk, Sun Hong [Hannam University, Daejeon (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension.

  6. In vitro haematic proteins adsorption and cytocompatibility study on acrylic copolymer to realise coatings for drug-eluting stents

    International Nuclear Information System (INIS)

    Gagliardi, Mariacristina

    2012-01-01

    In the present paper, a preliminary in vitro analysis of biocompatibility of newly-synthesised acrylic copolymers is reported. In particular, with the aim to obtain coatings for drug-eluting stents, blood protein absorption and cytocompatibility were studied. For protein absorption tests, bovine serum albumin and bovine plasma fibrinogen were considered. Cytocompatibility was tested using C2C12 cell line as model, analysing the behaviour of polymeric matrices and of drug-eluting systems, obtained loading polymeric matrices with paclitaxel, an anti-mitotic drug, in order to evaluate the efficacy of a pharmacological treatment locally administered from these materials. Results showed that the amount of albumin absorbed was greater than the amount of fibrinogen (comprised in the range of 70%–85% and 10%–22% respectively) and it is a good behaviour in terms of haemocompatibility. Cell culture tests showed good adhesion properties and a relative poor proliferation. In addition, a strong effect related to drug elution and a correlation with the macromolecular composition were detected. In this preliminary analysis, tested materials showed good characteristics and can be considered possible candidates to obtain coatings for drug-eluting stents. Highlights: ► Preliminary evaluation of haemo- and cytocompatibility of newly-synthesised acrylic copolymers ► Materials adsorb higher amounts of albumin and with a faster rate than fibrinogen. ► Protein adsorption depended on the macromolecular composition and surface properties. ► Cell viability on pure samples and efficacy of paclitaxel release were verified in C2C12 cultures.

  7. In vitro haematic proteins adsorption and cytocompatibility study on acrylic copolymer to realise coatings for drug-eluting stents

    Energy Technology Data Exchange (ETDEWEB)

    Gagliardi, Mariacristina, E-mail: mariacristina.gagliardi@iit.it

    2012-12-01

    In the present paper, a preliminary in vitro analysis of biocompatibility of newly-synthesised acrylic copolymers is reported. In particular, with the aim to obtain coatings for drug-eluting stents, blood protein absorption and cytocompatibility were studied. For protein absorption tests, bovine serum albumin and bovine plasma fibrinogen were considered. Cytocompatibility was tested using C2C12 cell line as model, analysing the behaviour of polymeric matrices and of drug-eluting systems, obtained loading polymeric matrices with paclitaxel, an anti-mitotic drug, in order to evaluate the efficacy of a pharmacological treatment locally administered from these materials. Results showed that the amount of albumin absorbed was greater than the amount of fibrinogen (comprised in the range of 70%-85% and 10%-22% respectively) and it is a good behaviour in terms of haemocompatibility. Cell culture tests showed good adhesion properties and a relative poor proliferation. In addition, a strong effect related to drug elution and a correlation with the macromolecular composition were detected. In this preliminary analysis, tested materials showed good characteristics and can be considered possible candidates to obtain coatings for drug-eluting stents. Highlights: Black-Right-Pointing-Pointer Preliminary evaluation of haemo- and cytocompatibility of newly-synthesised acrylic copolymers Black-Right-Pointing-Pointer Materials adsorb higher amounts of albumin and with a faster rate than fibrinogen. Black-Right-Pointing-Pointer Protein adsorption depended on the macromolecular composition and surface properties. Black-Right-Pointing-Pointer Cell viability on pure samples and efficacy of paclitaxel release were verified in C2C12 cultures.

  8. Arterial healing following primary PCI using the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) versus the durable polymer everolimus-eluting metallic stent (XIENCE) in patients with acute ST-elevation myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Onuma, Yoshinobu; Brugaletta, Salvatore

    2015-01-01

    Aims: The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with d...

  9. Patient-Centered Tablet Application for Improving Medication Adherence after a Drug-Eluting Stent.

    Science.gov (United States)

    Shah, Vicki; Dileep, Anandu; Dickens, Carolyn; Groo, Vicki; Welland, Betty; Field, Jerry; Baumann, Matthew; Flores, Jose D; Shroff, Adhir; Zhao, Zhongsheng; Yao, Yingwei; Wilkie, Diana J; Boyd, Andrew D

    2016-01-01

    This study's objective was to evaluate a patient-centered educational electronic tablet application, "My Interventional Drug-Eluting Stent Educational App" (MyIDEA) to see if there was an increase in patient knowledge about dual antiplatelet therapy (DAPT) and medication possession ratio (MPR) compared to treatment as usual. In a pilot project, 24 elderly (≥50 years old) research participants were recruited after a drug-eluting stent. Eleven were randomized to the control arm and 13 to the interventional arm. All the participants completed psychological and knowledge questionnaires. Adherence was assessed through MPR, which was calculated at 3 months for all participants who were scheduled for second and third follow-up visits. Relative to control, the interventional group had a 10% average increase in MPR. As compared to the interventional group, more patients in the control group had poor adherence (<80% MPR). The psychological data revealed a single imbalance in anxiety between the control and interventional groups. On average, interventional participants spent 21 min using MyIDEA. Consumer health informatics has enabled us to engage patients with their health data using novel methods. Consumer health technology needs to focus more on patient knowledge and engagement to improve long-term health. MyIDEA takes a unique approach in targeting DAPT from the onset. MyIDEA leverages patient-centered information with clinical care and the electronic health record highlighting the patients' role as a team member in their own health care. The patients think critically about adverse events and how to solve issues before leaving the hospital.

  10. Patient Centered Tablet Application for improving medication adherence after a Drug Eluting Stent

    Directory of Open Access Journals (Sweden)

    Vicki Shah

    2016-12-01

    Full Text Available Background/Aims: This study’s objective was to evaluate a patient-centered educational electronic tablet application, My Interventional Drug-Eluting Stent Educational App (MyIDEA to see if there was an increase in patient knowledge about dual antiplatelet therapy (DAPT and medication possession ratio (MPR compared to treatment as usual. Methods: In a pilot project, 24 elderly (≥50 years-old research participants were recruited after a Drug Eluting Stent. 11 were randomized to the control arm and 13 to the interventional arm. All participants completed psychological and knowledge questionnaires. Adherence was assessed through MPR, which was calculated at three months for all participants who were scheduled for a second and third follow-up visit.Results: Relative to control, the interventional group had a 10% average increase in MPR. As compared to the interventional group, more patients in the control group had poor adherence (<80% MPR. The psychological data revealed a single imbalance in anxiety between the control and interventional groups. On average interventional participants spent 21 minutes using MyIDEA. Discussion: Consumer health informatics has enabled us to engage patients with their health data using novel methods. Consumer health technology needs to focus more on patient knowledge and engagement to improve long term health. MyIDEA takes a unique approach in targeting DAPT from the onset.Conclusion: MyIDEA leverages patient centered information with clinical care and the electronic health record highlighting the patients’ role as a team member in their own healthcare. The patients think critically about adverse events and how to solve issues before leaving the hospital.

  11. Thrombosis of second-generation drug-eluting stents in real practice results from the multicenter Spanish registry ESTROFA-2 (Estudio Español Sobre Trombosis de Stents Farmacoactivos de Segunda Generacion-2).

    Science.gov (United States)

    de la Torre Hernández, José M; Alfonso, Fernando; Gimeno, Federico; Diarte, Jose A; Lopez-Palop, Ramón; Pérez de Prado, Armando; Rivero, Fernando; Sanchis, Juan; Larman, Mariano; Diaz, Jose F; Elizaga, Jaime; Moreiras, Javier Martín; Gomez Jaume, Alfredo; Hernández, José M; Mauri, Josepa; Recalde, Angel Sánchez; Bullones, Juan A; Rumoroso, Jose R; Del Blanco, Bruno García; Baz, Jose A; Bosa, Francisco; Botas, Javier; Hernández, Felipe

    2010-09-01

    This study sought to evaluate second-generation drug-eluting stent (DES) thrombosis in clinical practice. First-generation DES are associated with a significant incidence of late thrombosis. There is paucity of data regarding real practice late thrombosis incidence and predictors with second-generation DES, zotarolimus-eluting stent (ZES), and everolimus-eluting stents (EES). A prospective, large-scale, non-industry-linked multicenter registry was designed. Complete clinical-procedural data and systematic follow-up of all patients treated with these stents was reported in a dedicated registry supported by the Spanish Working Group on Interventional Cardiology. From 2005 to 2008, 4,768 patients were included in 34 centers: 2,549 treated with ZES, and 2,219 with EES. The cumulative incidence of definite/probable thrombosis for ZES was 1.3% at 1 year and 1.7% at 2 years and for EES 1.4% at 1 year and 1.7% at 2 years (p = 0.8). The increment of definite thrombosis between the first and second year was 0.2% and 0.25%, respectively. In a propensity score analysis, the incidence remained very similar. Ejection fraction (adjusted hazard ratio [HR]: 0.97; 95% confidence interval [CI]: 0.95 to -0.99; p = 0.008), stent diameter (adjusted HR: 0.37; 95% CI: 0.17to 0.81; p = 0.01) and bifurcations (adjusted HR: 2.1; 95% CI: 1.14 to 3.7; p = 0.02) emerged as independent predictors of thrombosis. In the subgroup of patients with bifurcations, the use of ZES was independently associated with a higher thrombosis rate (adjusted HR: 4; 95% CI: 1.1 to 13; p = 0.03). In a real practice setting, the incidence of thrombosis at 2 years with ZES and EES was low and quite similar. The incidence of very late thrombosis resulted lower than was reported in registries of first-generation DES. In the subset of bifurcations, the use of ZES significantly increased the risk of thrombosis. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  13. The SPIRIT V study: a clinical evaluation of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions.

    Science.gov (United States)

    Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra

    2011-02-01

    The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized

  14. Serial optical coherence tomography assessment of malapposed struts after everolimus-eluting stent implantation. A subanalysis from the HEAL-EES study

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Kohki [Cardiology Department, Cardiovascular Institute, Hospital Clínic, Institut d' Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Barcelona (Spain); Otsuki, Shuji [Division of Cardiology, Teikyo University Hospital, Tokyo (Japan); Giacchi, Giuseppe; Ortega-Paz, Luis [Cardiology Department, Cardiovascular Institute, Hospital Clínic, Institut d' Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Barcelona (Spain); Shiratori, Yoshitaka [Division of Cardiology, Teikyo University Hospital, Tokyo (Japan); Freixa, Xavier; Martín-Yuste, Victoria; Masotti, Mónica; Sabaté, Manel [Cardiology Department, Cardiovascular Institute, Hospital Clínic, Institut d' Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Barcelona (Spain); Brugaletta, Salvatore, E-mail: sabrugal@clinic.ub.es [Cardiology Department, Cardiovascular Institute, Hospital Clínic, Institut d' Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Barcelona (Spain)

    2017-01-15

    Background: Incomplete stent apposition (ISA) is related to stent thrombosis, which is a serious adverse event. We aim to assess the time-course of ISA after 2nd generation everolimus-eluting stent (EES) implantation. Methods: In HEAL-EES study, we enrolled 36 patients who underwent percutaneous coronary intervention (PCI) with EES. OCT imaging was performed at baseline and follow-up. Patients were randomized 1:1:1 into 3 groups according to the time in which follow-up was performed: group A (6-month), group B (9-month), and group C (12-month). In this subanalysis, patients who had ISA segments at baseline and/or follow-up OCT were analyzed. Result: At baseline, among 41 lesions in 36 patients, 20 lesions in 18 patients had ISA segments and were analyzed. At baseline, there were 3.0% ISA struts in group A (n = 8), 2.8% in group B (n = 4), and 4.5% in group C (n = 8). At follow-up, ISA struts were present in 0.09%, 0.16% and 0.64%; respectively in groups A, B, and C. At follow-up, there was a significant decrease in the frequency of ISA: group A 3.0% vs. 0.09% (p < 0.001), group B 2.8% vs. 0.16% (p < 0.001), and group C 4.5% vs. 0.64% (p < 0.001). In group A, there was one late acquired ISA at follow-up. Conclusions: In patients undergoing 2nd generation EES implantation, area of acute ISA assessed by OCT, was almost resolved at 6-month follow-up. - Highlights: • Time-course of incomplete stent apposition of everolimus-eluting stent was assessed. • Serial optical coherence tomography images at baseline and follow-up were evaluated. • Acute incomplete stent apposition was almost resolved as early as at 6 months.

  15. Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.

    Science.gov (United States)

    Costa, J Ribamar; Chamié, Daniel; Abizaid, Alexandre A C; Ribeiro, Expedito; Meireles, George C; Prudente, Maurício; Campos, Carlos A; Castro, Juliana P; Costa, Ricardo; Lemos, Pedro A

    2017-02-01

    We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.

  16. Direct comparison of coronary bare metal vs. drug-eluting stents: same platform, different mechanics?

    Science.gov (United States)

    Schmidt, Wolfram; Lanzer, Peter; Behrens, Peter; Brandt-Wunderlich, Christoph; Öner, Alper; Ince, Hüseyin; Schmitz, Klaus-Peter; Grabow, Niels

    2018-01-08

    Drug-eluting stents (DES) compared to bare metal stents (BMS) have shown superior clinical performance, but are considered less suitable in complex cases. Most studies do not distinguish between DES and BMS with respect to their mechanical performance. The objective was to obtain mechanical parameters for direct comparison of BMS and DES. In vitro bench tests evaluated crimped stent profiles, crossability in stenosis models, elastic recoil, bending stiffness (crimped and expanded), and scaffolding properties. The study included five pairs of BMS and DES each with the same stent platforms (all n = 5; PRO-Kinetic Energy, Orsiro: BIOTRONIK AG, Bülach, Switzerland; MULTI-LINK 8, XIENCE Xpedition: Abbott Vascular, Temecula, CA; REBEL Monorail, Promus PREMIER, Boston Scientific, Marlborough, MA; Integrity, Resolute Integrity, Medtronic, Minneapolis, MN; Kaname, Ultimaster: Terumo Corporation, Tokyo, Japan). Statistical analysis used pooled variance t tests for pairwise comparison of BMS with DES. Crimped profiles in BMS groups ranged from 0.97 ± 0.01 mm (PRO-Kinetic Energy) to 1.13 ± 0.01 mm (Kaname) and in DES groups from 1.02 ± 0.01 mm (Orsiro) to 1.13 ± 0.01 mm (Ultimaster). Crossability was best for low profile stent systems. Elastic recoil ranged from 4.07 ± 0.22% (Orsiro) to 5.87 ± 0.54% (REBEL Monorail) including both BMS and DES. The bending stiffness of crimped and expanded stents showed no systematic differences between BMS and DES neither did the scaffolding. Based on in vitro measurements BMS appear superior to DES in some aspects of mechanical performance, yet the differences are small and not class uniform. The data provide assistance in selecting the optimal system for treatment and assessment of new generations of bioresorbable scaffolds. not applicable.

  17. A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Directory of Open Access Journals (Sweden)

    Wehrenberg Scott

    2010-01-01

    Full Text Available Abstract Background Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials. Methods/Design The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1, single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express2 paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to Discussion The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at http://www.clinicaltrials.gov, identification numbers NCT00484315 and NCT00489541.

  18. Very late stent thrombosis with second generation drug eluting stents compared to bare metal stents: Network meta-analysis of randomized primary percutaneous coronary intervention trials.

    Science.gov (United States)

    Philip, Femi; Stewart, Susan; Southard, Jeffrey A

    2016-07-01

    The relative safety of drug-eluting stents (DES) and bare-metal stents (BMS) in primary percutaneous coronary intervention (PPCI) in ST elevation myocardial infarction (STEMI) continues to be debated. The long-term clinical outcomes between second generation DES and BMS for primary percutaneous coronary intervention (PCI) using network meta-analysis were compared. Randomized controlled trials comparing stent types (first generation DES, second generation DES, or BMS) were considered for inclusion. A search strategy used Medline, Embase, Cochrane databases, and proceedings of international meetings. Information about study design, inclusion criteria, and sample characteristics were extracted. Network meta-analysis was used to pool direct (comparison of second generation DES to BMS) and indirect evidence (first generation DES with BMS and second generation DES) from the randomized trials. Twelve trials comparing all stents types including 9,673 patients randomly assigned to treatment groups were analyzed. Second generation DES was associated with significantly lower incidence of definite or probable ST (OR 0.59, 95% CI 0.39-0.89), MI (OR 0.59, 95% CI 0.39-0.89), and TVR at 3 years (OR 0.50: 95% CI 0.31-0.81) compared with BMS. In addition, there was a significantly lower incidence of MACE with second generation DES versus BMS (OR 0.54, 95% CI 0.34-0.74) at 3 years. These were driven by a higher rate of TVR, MI and stent thrombosis in the BMS group at 3 years. There was a non-significant reduction in the overall and cardiac mortality [OR 0.83, 95% CI (0.60-1.14), OR 0.88, 95% CI (0.6-1.28)] with the use of second generation DES versus BMS at 3 years. Network meta-analysis of randomized trials of primary PCI demonstrated lower incidence of MACE, MI, TVR, and stent thrombosis with second generation DES compared with BMS. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Evaluation of chemical stability of polymers of XIENCE everolimus-eluting coronary stents in vivo by pyrolysis-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Kamberi, Marika; Pinson, David; Pacetti, Stephen; Perkins, Laura E L; Hossainy, Syed; Mori, Hiroyoshi; Rapoza, Richard J; Kolodgie, Frank; Virmani, Renu

    2017-09-07

    The polymers poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) and poly(n-butyl methacrylate) (PBMA) are employed in manufacturing the XIENCE family of coronary stents. PBMA serves as a primer and adheres to both the stent and the drug coating. PVDF-HFP is employed in the drug matrix layer to hold the drug everolimus on the stent and control its release. Chemical stability of the polymers of XIENCE stents in the in-vivo environment was evaluated by pyrolysis-gas chromatography with mass spectrometry (Py-GC/MS) detection. For this evaluation, XIENCE stents explanted from porcine coronary arteries and from human coronary artery specimens at autopsy after 2-4 and 5-7 years of implantation, respectively, were compared to freshly manufactured XIENCE stents (controls). The comparison of pyrograms of explanted stent samples and controls showed identical fragmentation fingerprints of polymers, indicating that PVDF-HFP and PBMA maintained their chemical integrity after multiple years of XIENCE coronary stent implantation. The findings of the present study demonstrate the chemical stability of PVDF-HFP and PBMA polymers of the XIENCE family of coronary stents in the in-vivo environment, and constitute a further proof of the suitability of PVDF-HFP as a drug carrier for the drug eluting stent applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.

  20. Comparative vascular responses three months after paclitaxel and everolimus-eluting stent implantation in streptozotocin-induced diabetic porcine coronary arteries

    Directory of Open Access Journals (Sweden)

    Sheehy Alexander

    2012-06-01

    Full Text Available Abstract Background Diabetes remains a significant risk factor for restenosis/thrombosis following stenting. Although vascular healing responses following drug-eluting stent (DES treatment have been characterized previously in healthy animals, comparative assessments of different DES in a large animal model with isolated features of diabetes remains limited. We aimed to comparatively assess the vascular response to paclitaxel-eluting (PES and everolimus-eluting (EES stents in a porcine coronary model of streptozotocin (STZ-induced type I diabetes. Method Twelve Yucatan swine were induced hyperglycemic with a single STZ dose intravenously to ablate pancreatic β-cells. After two months, each animal received one XIENCE V® (EES and one Taxus Liberte (PES stent, respectively, in each coronary artery. After three months, vascular healing was assessed by angiography and histomorphometry. Comparative in vitro effects of everolimus and paclitaxel (10-5 M–10-12 M after 24 hours on carotid endothelial (EC and smooth muscle (SMC cell viability under hyperglycemic (42 mM conditions were assayed by ELISA. Caspase-3 fluorescent assay was used to quantify caspase-3 activity of EC treated with everolimus or paclitaxel (10-5 M, 10-7 M for 24 hours. Results After 3 months, EES reduced neointimal area (1.60 ± 0.41 mm, p vs. 0.08 ± 0.05, greater medial necrosis grade (0.52 ± 0.26 vs. 0.0 ± 0.0, and persistently elevated fibrin scores (1.60 ± 0.60 vs. 0.63 ± 0.41 with PES compared to EES (p In vitro, paclitaxel significantly increased (p -7 M, while everolimus did not affect EC/SMC apoptosis/necrosis within the dose range tested. In ECs, paclitaxel (10-5 M significantly increased caspase-3 activity (p  Conclusion After 3 months, both DES exhibited signs of delayed healing in a STZ-induced diabetic swine model. PES exhibited greater neointimal area, increased inflammation, greater medial necrosis, and

  1. Outcomes after revascularisation with everolimus- and sirolimus-eluting stents in patients with acute coronary syndromes and stable angina pectoris

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Hansen, Henrik S

    2014-01-01

    ): cardiac death, myocardial infarction (MI), stent thrombosis, or target vessel revascularisation within 18 months. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated for the endpoints. At 18-month follow-up, patients with ACS had higher rates of MACE compared to patients with SAP (8...

  2. Impact of Hemoglobin A1c Levels on Residual Platelet Reactivity and Outcomes After Insertion of Coronary Drug-Eluting Stents (from the ADAPT-DES Study)

    DEFF Research Database (Denmark)

    Schoos, Mikkel M.; Dangas, George D.; Mehran, Roxana

    2016-01-01

    An increasing hemoglobin A1c (HbA1c) level portends an adverse cardiovascular prognosis; however, the association between glycemic control, platelet reactivity, and outcomes after percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is unknown. We sought to investigate whether Hb...... With Drug Eluting Stents registry, HbA1c levels were measured as clinically indicated in 1,145 of 8,582 patients, stratified by HbA1c 8.5% (n = 171, 14.9%). HPR on clopidogrel and aspirin was defined after PCI as P2Y12 reaction units (PRU) >208...... >208 (42.5%, 50.2%, and 62.3%, p definite or probable stent thrombosis (ST; 0.9%, 2.7%, and 4.2%, p = 0.02) increased progressively with HbA1c groups. Clinically relevant bleeding was greatest in the intermediate HbA1c group (8.2% vs 13.1% vs 9.5%, p = 0.04). In adjusted models...

  3. Comparison between Exclusive and Selective Drug-Eluting Stent Strategies in Treating Patients with Multivessel Coronary Artery Disease.

    Science.gov (United States)

    Tung, Ying-Chang; Hsiao, Ping-Gune; Hsu, Lung-An; Kuo, Chi-Tai; Chang, Chi-Jen

    2014-05-01

    The expanded usage of drug-eluting stents (DES) in treating patients with multivessel coronary artery disease (CAD) may sometimes be limited in real-world practice due to cost concerns. We compared the clinical outcomes of exclusive and selective DES use in treating patients with multivessel CAD. From November 2004 to December 2011, 110 patients with multivessel CAD who received four or more stents were enrolled into this study, and divided into two groups according to the DES strategy employed: exclusive DES (n = 52), or selective DES (n = 58). In the selective DES group, DES was reserved for complex lesions only, such that the incidence and predictors of clinical events were assessed. At a mean follow-up of 41.4 ± 26.5 months, there were no significant differences between the two strategies in terms of baseline characteristics, all-cause mortality (exclusive vs. selective: 1.9% vs. 6.9%, p = 0.21), cardiac death (1.9% vs. 1.7%, p = 0.94) and nonfatal myocardial infarction (3.8% vs. 5.2%, p = 0.74). Despite the presence of more ostial lesions in the exclusive DES group, there was a trend such that major adverse cardiac events (MACE) and target lesion revascularization (TLR) rates were higher in the selective DES group (MACE: 17.3% vs. 31%, p = 0.16; TLR: 11.5% vs. 24.1%, p = 0.08). The higher MACE rate in the selective DES group was mainly driven by a higher target vessel revascularization (TVR) rate (15.4% vs. 29.3%, p = 0.08). In the exclusive DES group, SYNTAX score was an independent predictor of MACE [Haxard ratio (HR): 1.09, 95% confidence internal (CI): 1.02-1.16, p = 0.01] and TVR (HR 1.08, 95% CI 1.01-1.15, p = 0.04). Compared to the exclusive DES strategy, the selective DES strategy with reservation of DES for complex lesions is associated with numerically higher, but not statistically significant, rates of MACE and all-cause mortality in this small group of patients with multivessel CAD receiving four or more stents. Bare metal stent; Drug-eluting

  4. 10-Year Clinical Outcome After Randomization to Treatment by Sirolimus- or Paclitaxel-Eluting Coronary Stents

    DEFF Research Database (Denmark)

    Galløe, Anders M; Kelbæk, Henning; Thuesen, Leif

    2017-01-01

    of patients included in a large randomized trial for 10 years to enable detection of late changes in annual event rates that could necessitate medical attention. METHODS: A total of 2,098 unselected all-comer patients (50% with acute coronary syndrome) were randomly assigned to have a first-generation DES...... for both stent types, with no apparent late changes. Although there is no need for extraordinary medical attention for these patients, the absence of declines in annual event rates calls for continuous surveillance. (Danish Organization on Randomized Trials With Clinical Outcome II [SORT OUT II]; NCT...

  5. Percutaneous Coronary Intervention of Left Main Disease: Pre- and Post-EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) Era.

    Science.gov (United States)

    Park, Duk-Woo; Park, Seung-Jung

    2017-06-01

    For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.

  6. Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study

    Energy Technology Data Exchange (ETDEWEB)

    Otsuki, Shuji; Brugaletta, Salvatore, E-mail: sabrugal@clinic.ub.es; Sabaté, Manel; Shiratori, Yoshitaka; Gomez-Monterrosas, Omar; Scalone, Giancarla; Romero-Villafañe, Sebastian; Hernández-Enríquez, Marco; Freixa, Xavier; Martín-Yuste, Victoria; Masotti, Mónica

    2016-06-15

    Purpose: Second-generation drug-eluting stent (DES) have shown a better safety and efficacy as compared to first generation DES due to an improved vascular healing process. This process has not been so far evaluated in vivo in an overtime fashion by optical coherent tomography (OCT). We sought to evaluate the vascular healing process after everolimus-eluting stent (EES) implantation at 6, 9 and 12 months, by OCT. Methods: Consecutive 36 patients undergoing percutaneous coronary intervention with EES were randomized 1:1:1 to receive OCT imaging at 6 (group A), 9 (group B) or 12-month follow-up (group C). One patient from group C was excluded because of target lesion revascularization at 1-month, whereas 5 patients withdraw the informed consent. Finally, 30 patients were analyzed. Results: Neointimal thickness was not different between 3 groups (group A: 99.50 [94.06–127.79] μm, group B: 107.26 [83.48–133.59] μm, group C: 127.67 [102.51–138.49] μm; p = 0.736). Although the percentage of “uncovered struts” was significantly higher in group A as compared to the other groups (8.0% vs. 4.4% vs. 2.9%, respectively; p = 0.180), the ratio of uncovered to total struts per section < 30% was similar between 3 groups (0.3% vs. 0.3% vs. 0%, respectively; p = 1.000). Conclusion: Healing process following EES implantation seems almost completed at 6-month follow-up. These data, which need to be confirmed in a larger study, may support the decision to shorten dual antiplatelet therapy. - Highlights: • Healing process following everolimus-eluting stent implantation is complete at 6-month • There are no difference in RUTTS > 30% between 6, 9 and 12 months analyses. • This finding may support to shorten dual antiplatelet therapy in this context.

  7. Risk factors for impaired health status differ in women and men treated with percutaneous coronary intervention in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Ong, Andrew T L; Lemos, Pedro A

    2006-01-01

    In patients treated with percutaneous coronary intervention (PCI) in the drug-eluting stent era, we compared women's and men's health status 6 and 12 months post-PCI and investigated whether predictors of poor health status at 12 months are similar for women and men....

  8. Enhanced performance of magnesium alloy for drug-eluting vascular scaffold application

    Science.gov (United States)

    Dong, Hongzhou; Li, Daikun; Mao, Daoyong; Bai, Ningning; Chen, Yashi; Li, Qing

    2018-03-01

    Bio-absorbable magnesium alloys drug-eluting vascular scaffold was developed to resolve the defect of permanent metal and drug-eluting stents, most notably a chronic vessel wall inflammation and the risk of stent thrombosis. Nevertheless, violent chemical reaction and rapid degradation under physiological conditions limits their application. Furthermore, multifunctional drug-eluting stents which could reduce the formation of thrombus and repair the damaged vessels need more attention to fundamentally cure the coronary artery disease. Herein, a drug delivery system (Mg/MgO/PLA-FA) which can realize sustainable release of ferulaic acid was designed via anodic oxidation process and dip coating process. Electrochemical tests and immersion experiments showed that the superior anticorrosion behavior, it is due to the dense MgO-PLA composite layer. The released ferulaic acid can effectively decrease platelets adhesion and aggregation during the early stage of implantation. Besides, hemolysis tests showed that the composite coatings endowed the Mg alloy with a low hemolysis ratio. The Mg/MgO/PLA-FA composite materials may be appropriate for applications on biodegradable Mg alloys drug-eluting stents.

  9. The Effect of Cilostazol on the Angiographic Outcome of Drug-Eluting Coronary Stents Angiographic Analysis of the CILON-T (Influence of CILostazol-Based Triple Antiplatelet Therapy ON Ischemi Complication after Drug-Eluting StenT Implantation) Trial.

    Science.gov (United States)

    Suh, Jung-Won; Lee, Seung-Pyo; Park, KyungWoo; Kang, Hyun-Jae; Koo, Bon-Kwon; Cho, Young-Seok; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju; Rha, Seung-Woon; Bae, Jang-Ho; Kwon, Taek-Geun; Bae, Jang-Whan; Cho, Myeong-Chan; Kim, Hyo-Soo

    2017-12-12

    It is not clear if anti-restonotic effect of cilostazol is consistent for different types of drug-eluting stents (DES).The purpose of this study was to compare the anti-proliferative effect of cilostazol between DAT and TAT with consideration of confounding influences of DES type.Nine hundred and fifteen patients were randomized to either dual antiplatelet therapy (DAT; aspirin and clopidogrel) or triple antiplatelet therapy (TAT; aspirin, clopidogrel, and cilostazol) in the previous CILON-T trial. After excluding 70 patients who received both or neither stents, we analyzed 845 patients who received exclusively PES or ZES, and compared in-stent late loss at 6 months between both antiplatelet regimens (DAT versus TAT).Baseline angiographic and clinical characteristics were similar between the DAT (656 lesions in 425 patients) and the TAT group (600 lesions in 420 patients). The 6-month follow-up angiography was completed in 745 patients (88.2%). Quantitative coronary angiography showed that TAT significantly reduced in-stent late loss (DAT 0.62 ± 0.62 mm versus TAT 0.54 ± 0.49 mm, P = 0.015). Stent type, diabetes or lesion length did not interact with difference of late loss. However, reduction of late loss by cilostazol did not lead to a significant reduction in the rate of target lesion revascularization (TLR) (DAT 7.8% versus TAT 6.9%, P = 0.69) due to a nonlinear relationship found between late loss and TLR.The TAT group showed less in-stent late loss as compared to the DAT group. This was consistently observed regardless of DES type, lesion length, or diabetic status. However, reduction of late loss by cilostazol did not lead to a significant reduction in TLR.

  10. Comparison of outcome in 1809 patients treated with drug-eluting stents or bare-metal stents in a real-world setting

    Directory of Open Access Journals (Sweden)

    Vogt A

    2011-11-01

    Full Text Available Alexander Vogt1, Anke Schoelmerich1, Franziska Pollner1, Manuela Schlitt1, Uwe Raaz1, Lars Maegdefessel2, Iris Reindl1, Michael Buerke1, Karl Werdan1, Axel Schlitt11Department of Medicine III, Martin Luther-University, Halle, Germany; 2Division of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, CA, USAPurpose: The aim of this study was to determine the long-term safety of drug-eluting stent (DES versus bare metal stent (BMS implantation in a “real-world” setting.Patients and methods: A total of 1809 patients who were treated with implantation of either BMS or DES were assessed. Kaplan-Meier and multivariate Cox regression analyses concerning primary endpoint of cardiac mortality were performed.Results: A total of 609 patients received DES. Mean age was 66.2 ± 11.3 years, 69.4% were male, and 1517 (83.8% were treated for acute coronary syndrome (unstable angina 510 [28.2%], non-ST-elevation myocardial infarction [NSTEMI] 506 [28.0%], and ST-elevation myocardial infarction [STEMI] 501 [27.7%]. Mean follow-up was 34 ± 15 months. During follow-up, 268 patients died of cardiac causes (DES 42 [7.3%]; BMS 226 [19.6%]; P < 0.001. Univariate Kaplan-Meier analysis showed an advantage of DES over BMS concerning the primary endpoint (P < 0.001. When adjusting for classic risk factors and additional factors that affect the progression of coronary heart disease (CHD, DES was not found to be superior to BMS (hazard ratio 0.996, 95% confidence interval 0.455–2.182, P = 0.993. Severely impaired renal function was an independent predictor for cardiac mortality after stent implantation.Conclusion: Treatment with DES is safe in the long term, also in patients presenting with STEMI. However, in multivariate analyses it is not superior to BMS treatment.Keywords: coronary stent, outcome, renal insufficiency, myocardial infarction, STEMI

  11. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 ± 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 ± 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 ± 9.1 %, lesion binary restenosis rate was 64.1 ± 8.3 %, and repeat intervention-free survival was 93.6 ± 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications

  12. Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr; Diamantopoulos, Athanasios; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [School of Medicine, Patras University Hospital, Department of Interventional Radiology (Greece)

    2013-08-01

    PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

  13. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound.

    Science.gov (United States)

    Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-04-01

    We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p 3years to stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Coronary Artery Bypass Surgery Versus Drug-Eluting Stent Implantation for Left Main or Multivessel Coronary Artery Disease A Meta-Analysis of Individual Patient Data

    NARCIS (Netherlands)

    Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W.; Park, Seung-Jung

    2016-01-01

    OBJECTIVES The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD).

  15. The role of drug-eluting balloons alone or in combination with drug-eluting stents in the treatment of de novo diffuse coronary disease.

    Science.gov (United States)

    Costopoulos, Charis; Latib, Azeem; Naganuma, Toru; Sticchi, Alessandro; Figini, Filippo; Basavarajaiah, Sandeep; Carlino, Mauro; Chieffo, Alaide; Montorfano, Matteo; Naim, Charbel; Kawaguchi, Masanori; Giannini, Francesco; Colombo, Antonio

    2013-11-01

    This study sought to investigate the role of drug-eluting balloons (DEB) alone or in combination with drug-eluting stents (DES) in the treatment of diffuse de novo coronary artery disease (CAD) (>25 mm). The use of DEB in diffuse CAD, either alone or in combination with DES, offers an alternative to stenting alone. Data regarding DEB in this context are limited. We retrospectively evaluated all patients treated with DEB for diffuse CAD between June 2009 and October 2012. Endpoints analyzed were major adverse cardiac events, defined as all-cause death, myocardial infarction, and target vessel revascularization (TVR), as well as TVR and target lesion revascularization separately. Results were compared with those obtained from a cohort of patients with similar characteristics treated with DES alone. A total of 69 patients (93 lesions) were treated with DEB ± DES, and 93 patients with DES alone (93 lesions). A high proportion of patients were diabetic (46.4% vs. 44.1%, p = 0.77). Of the DEB-treated lesions, 56.0% were treated with DEB alone, 7.4% with DEB and DES as bail out, and 36.6% with DES and DEB as part of a hybrid approach for very long disease. Outcome rates with DEB ± DES were comparable to those with DES alone at 2-year follow-up (major adverse cardiac events = 20.8% vs. 22.7%, p = 0.74; TVR = 14.8% vs. 11.5%, p = 0.44; target lesion revascularization = 9.6% vs. 9.3%, p = 0.84). DEB may have a role in the treatment of diffuse de novo CAD, either alone in smaller vessels or in combination with DES in very long disease. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Clinical outcome after primary percutaneous coronary intervention with drug-eluting and bare metal stents in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Maeng, Michael; Thayssen, Per

    2008-01-01

    BACKGROUND: The use of drug-eluting stents (DESs) versus bare metal stents (BMSs) in primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction is a matter of debate. Therefore, we examined the risk of target lesion revascularization (TLR), stent thrombosis...... Registry from January 2002 through June 2005, were followed up for 2 years. We used Cox regression analysis to control for confounding. The 2-year incidence of definite stent thrombosis was 1.9% in the DES group and 1.1% in the BMS group (adjusted relative risk [RR]=1.53; 95% CI=0.84 to 2.78; P=0.17). Very...... late definite stent thrombosis (> or =12 months) was seen in 0.4% in the DES group and 0.06% in the BMS group (adjusted RR=6.74; 95% CI=1.23 to 37.00; P=0.03). The 2-year incidence of myocardial infarction was similar in the 2 groups, 5.2% in the DES group versus 6.3% in the BMS group (P=0.28; adjusted...

  17. Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers.

    Science.gov (United States)

    Kan, Jing; Ge, Zhen; Zhang, Jun-Jie; Liu, Zhi-Zhong; Tian, Nai-Liang; Ye, Fei; Li, Sui-Ji; Qian, Xue-Song; Yang, Song; Chen, Meng-Xuan; Rab, Tanveer; Chen, Shao-Liang

    2016-06-13

    The present study aimed to analyze the incidence of SF and its correlation with clinical events after DES implantation and the outcome of re-intervention for symptomatic in-stent restenosis (ISR) induced by stent fracture (SF). SF is associated with a high rate of clinical events after the implantation of drug-eluting stents (DES). However, the chronological rate of SF and the effect of SF on clinical outcomes from a large patient population remain underreported. A total of 6,555 patients with 16482 DES in 10751 diseased vessels and surveillance angiography between November 2003 and January 2014 were prospectively studied. The primary endpoints included the incidence of SF, in-stent restenosis (ISR), target lesion revascularization (TLR), and definite stent thrombosis (ST) at the end of follow-up before and after propensity score matching. Clinical outcomes after TLR were also followed up. The SF rate was detected in 803 (12.3%) patients, 3,630 (22.0%) stents, and 1,852 (17.2%) diseased vessels. SF increased over time. SF was associated with higher unadjusted rates of ISR (42.1%), TLR (24.8%, n = 379), and definite ST (4.6%) compared with stents without fracture (10.7%, 6.6%, and 1.03%, all p stents after reintervention, and 6 (7.5%) stents required repeat TLR. SF is more frequently observed after DES implantation. TLR was required in almost one-fourth of fractured stents. Increased events in the SF group did not translate into a difference in mortality compared with the non-SF group. Reintervention was associated with acceptable clinical results. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Cirugía de revascularización miocárdica versus stent farmacoactivos en pacientes con enfermedad de tronco común izquierdo: una revisión sistemática de ensayos clínicos aleatorizados y de metaanálisis de ensayos clínicos aleatorizados

    Directory of Open Access Journals (Sweden)

    Stefano Urso

    2018-03-01

    úrgico, el riesgo de necesitar un nuevo procedimiento de revascularización miocárdica por parte de la población percutánea fue aproximadamente el doble del de la población quirúrgica. Abstract: Objective: The aim of this systematic review is to analyze in the literature the clinical results of coronary artery bypass grafting (CABG versus percutaneous coronary intervention with drug-eluting stents in patients with left main stem disease. Methods: We carried out a literature search using Pubmed, Google Scholar, Medline, Embase and Cochrane databases. We limited our search to randomized controlled trials or meta-analyses carried out on randomized controlled trials, with no year of publication or language restriction. Results: Eighty-two articles were found using the search methodology described. Of these, 14 articles were selected: 7 papers from 5 randomized non-inferiority clinical trials (SYNTAX, PRECOMBAT, study by Boudriot et al., NOBLE and EXCEL and 7 meta-analyses. These trials have compared first generation drug-eluting stents (SYNTAX: stent with paclitaxel; Boudriot et al. and PRECOMBAT: stent with sirolimus and second-generation drug-eluting stents (NOBLE: stent with biolimus; EXCEL: stent with cobalt-chromium everolimus with CABG.With reference to the coronary revascularization procedure, bilateral internal mammary artery use ranged from 7.4% to 54.4%. All the included randomized trials reported a lower rate of repeated revascularization in the surgical population. According to the meta-analyses review, the risk, expressed as odds ratio, of requiring a new myocardial revascularization procedure by the percutaneous population compared with that one of the surgical population, ranged from 1.68 to 2.21. Conclusions: Independently from the type of drug eluting stent used in the percutaneous procedures and despite low rate of bilateral internal mammary artery used in the surgical group, the risk of requiring a new myocardial revascularization procedure by the

  19. DMSO inhibits human platelet activation through cyclooxygenase-1 inhibition. A novel agent for drug eluting stents?

    International Nuclear Information System (INIS)

    Asmis, Lars; Tanner, Felix C.; Sudano, Isabella; Luescher, Thomas F.; Camici, Giovanni G.

    2010-01-01

    Background: DMSO is routinely infused together with hematopoietic cells in patients undergoing myeloablative therapy and was recently found to inhibit smooth muscle cells proliferation and arterial thrombus formation in the mouse by preventing tissue factor (TF), a key activator of the coagulation cascade. This study was designed to investigate whether DMSO prevents platelet activation and thus, whether it may represent an interesting agent to be used on drug eluting stents. Methods and results: Human venous blood from healthy volunteers was collected in citrated tubes and platelet activation was studied by cone and platelet analyzer (CPA) and rapid-platelet-function-assay (RPFA). CPA analysis showed that DMSO-treated platelets exhibit a lower adherence in response to shear stress (-15.54 ± 0.9427%, n = 5, P < 0.0001 versus control). Additionally, aggregometry studies revealed that DMSO-treated, arachidonate-stimulated platelets had an increased lag phase (18.0% ± 4.031, n = 9, P = 0.0004 versus control) as well as a decreased maximal aggregation (-6.388 ± 2.212%, n = 6, P = 0.0162 versus control). Inhibitory action of DMSO could be rescued by exogenous thromboxane A2 and was mediated, at least in part, by COX-1 inhibition. Conclusions: Clinically relevant concentrations of DMSO impair platelet activation by a thromboxane A2-dependent, COX-1-mediated effect. This finding may be crucial for the previously reported anti-thrombotic property displayed by DMSO. Our findings support a role for DMSO as a novel drug to prevent not only proliferation, but also thrombotic complications of drug eluting stents.

  20. Technological Advances in Stent Therapies: a Year in Review.

    Science.gov (United States)

    Raffoul, Jad; Nasir, Ammar; Klein, Andrew J P

    2018-04-07

    Stent technology has rapidly evolved since the first stainless steel bare metal stents with substantial developments in scaffolding, polymer, drug choice, drug delivery, and elution mechanisms. Most recently, there has been the evolution of bioabsorbable vascular scaffolds, potentially eliminating the need for long-term foreign object retention. These rapid developments have led to an ever-expanding selection of new stents, making the choice of which to use in which patient challenging. Operators must balance potential short- and long-term clinical ramifications, namely stent thrombosis, in-stent restenosis, target lesion revascularization, and target lesion failure. In this review, we hope to provide insight for interventional cardiologists on the details of stent technology and how this impacts outcomes, stent selection, and duration of dual-antiplatelet therapy duration post drug-eluting stent implantation.

  1. Successful drug-eluting stent implantation in a male patient with dextrocardia: a case report

    Directory of Open Access Journals (Sweden)

    Long Wenjie

    2017-12-01

    Full Text Available Situs inversus with dextrocardia is a rare condition, with complete transposition of all the body organs, including the heart. Percutaneous coronary intervention (PCI in these patients is technically difficult because of the mirror image of organs. Here, we describe a 56-year-old man with coronary heart disease with known situs inversus with dextrocardia and coronary percutaneous intervention was performed for stenosis in the right coronary artery. A drug eluting stent was implanted at this site successfully. This case suggested that the interventional management of such patients follows the same general rules as for non-dextrocardia patients, but the manipulation of the catheter and projection position choices need to be taken into consideration to obtain optimal benefits for the patient.

  2. Determining clinical benefits of drug-eluting coronary stents according to the population risk profile: a meta-regression from 31 randomized trials.

    Science.gov (United States)

    Moreno, Raul; Martin-Reyes, Roberto; Jimenez-Valero, Santiago; Sanchez-Recalde, Angel; Galeote, Guillermo; Calvo, Luis; Plaza, Ignacio; Lopez-Sendon, Jose-Luis

    2011-04-01

    The use of drug-eluting stents (DES) in unfavourable patients has been associated with higher rates of clinical complications and stent thrombosis, and because of that concerns about the use of DES in high-risk settings have been raised. This study sought to demonstrate that the clinical benefit of DES increases as the risk profile of the patients increases. A meta-regression analysis from 31 randomized trials that compared DES and bare-metal stents, including overall 12,035 patients, was performed. The relationship between the clinical benefit of using DES (number of patients to treat [NNT] to prevent one episode of target lesion revascularization [TLR]), and the risk profile of the population (rate of TLR in patients allocated to bare-metal stents) in each trial was evaluated. The clinical benefit of DES increased as the risk profile of each study population increased: NNT for TLR=31.1-1.2 (TLR for bare-metal stents); prisk profile of each study population, since the effect of DES in mortality, myocardial infarction, and stent thrombosis, was not adversely affected by the risk profile of each study population (95% confidence interval for β value 0.09 to 0.11, -0.12 to 0.19, and -0.03 to-0.15 for mortality, myocardial infarction, and stent thrombosis, respectively). The clinical benefit of DES increases as the risk profile of the patients increases, without affecting safety. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    Science.gov (United States)

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017

  4. Short and long-term safety and efficacy of polymer-free vs. durable polymer drug-eluting stents. A comprehensive meta-analysis of randomized trials including 6178 patients

    NARCIS (Netherlands)

    Navarese, E.P.; Kowalewski, M.; Cortese, B.; Kandzari, D.; Dias, S.; Wojakowski, W.; Buffon, A.; Lansky, A.; Angelini, P.; Torguson, R.; Kubica, J.; Kelm, M.; Boer, M.J. de; Waksman, R.; Suryapranata, H.

    2014-01-01

    BACKGROUND: The efficacy and safety of polymer-free drug-eluting stents (DESs) in clinical practice is currently subject of debate; randomized trials (RCTs) conducted so far provided conflicting results or were underpowered to definitively address this question; we aimed to investigate the efficacy

  5. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial

    DEFF Research Database (Denmark)

    Kelbaek, H.; Klovgaard, L.; Helqvist, S.

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...

  6. [Comparison of DK crush with classical crush technique with drug-eluting stents for the treatment of coronary bifurcation lesions from DKCRUSH-1 study].

    Science.gov (United States)

    Chen, Shao-liang; Zhang, Jun-jie; Ye, Fei; Chen, Yun-dai; Lü, Shu-zheng; Tan, Huaycheem; Patel, Tejas; Kenji, Kawajiri; Tamari, Israel; Shan, Shou-jie; Zhu, Zhong-sheng; Lin, Song; Tian, Nai-liang; Li, Xiao-bo; Liu, Zhi-zhong; Lee, Michael; Wei, Meng; Xu, Ya-wei; Yuan, Zheng-bai; Qian, Jun; Sun, Xue-wen; Yang, Song; Chen, Jin-guo; He, Ben; Sumit, Suji

    2008-02-01

    To determine independent factors correlated with clinical effects of DK crush and classical crush technique with drug-eluting stents on bifurcation lesions. 311 patients with bifurcation lesions were randomized to classical (C, n = 156) or double kissing (DK) crush (n = 155) stent implantation group. The primary endpoints included major adverse cardiac events (MACE). Final kissing balloon inflation (FKBI) success rate was 76% in C and 100% in DK groups (P DK crush procedure was characterized by lower unsatisfactory FKBI rate (27.6% vs.6.3%, P DK groups (P = 0.01), respectively. Cumulative 8-month MACE was 35.9% in without-FKBI and 19.7% in with-FKBI sub-groups, and 11.4% in DK group (P = 0.02). The incidence of stent thrombosis was 3.2% in C group (5.1% without vs. 1.7% with FKBI) and 1.3% in DK group (P > 0.05). The predictive factors of MACE included minimal side branch stent lumen diameter and lack of DK crush technique. DK crush technique is an alternative of double stenting techniques in terms of improvement of restenosis and clinical outcomes.

  7. Factors Associated with the Use of Drug-Eluting Stents in Patients Presenting with Acute ST-Segment Elevation Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Jose F. Chavez

    2015-01-01

    Full Text Available Background. Drug-eluting stents (DES have proven clinical superiority to bare-metal stents (BMS for the treatment of patients with ST-segment elevation myocardial infarction (STEMI. Decision to implant BMS or DES is dependent on the patient’s ability to take dual antiplatelet therapy. This study investigated factors associated with DES placement in STEMI patients. Methods. Retrospective analysis was performed on 193 patients who presented with STEMI and were treated with percutaneous coronary intervention at an urban, tertiary care hospital. Independent factors associated with choice of stent type were determined using stepwise multivariate logistic regression. Odds ratio (OR was used to evaluate factors significantly associated with DES and BMS. Results. 128 received at least one DES, while 65 received BMS. BMS use was more likely in the setting of illicit drug or alcohol abuse ([OR] 0.15, 95% CI 0.05–0.48, p≤0.01, cardiogenic shock (OR 0.26, 95% CI 0.10–0.73, p=0.01, and larger stent diameter (OR 0.28, 95% CI 0.11–0.68, p≤0.01. Conclusions. In this analysis, BMS implantation was associated with illicit drug or alcohol abuse and presence of cardiogenic shock. This study did not confirm previous observations that non-White race, insurance, or income predicts BMS use.

  8. Two-Year Clinical Outcomes of Newer-Generation Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions.

    Science.gov (United States)

    Jinnouchi, Hiroyuki; Kuramitsu, Shoichi; Shinozaki, Tomohiro; Kobayashi, Yohei; Hiromasa, Takashi; Morinaga, Takashi; Mazaki, Toru; Sakakura, Kenichi; Soga, Yoshimitsu; Hyodo, Makoto; Shirai, Shinichi; Ando, Kenji

    2015-01-01

    Clinical outcomes of implantation of the newer-generation drug-eluting stent (DES) following rotational atherectomy for heavily calcified lesions remain unclear in the real-world setting. We enrolled 252 consecutive patients (273 lesions) treated with newer-generation DES following rotational atherectomy. The primary endpoint was the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as cardiac death, myocardial infarction, clinically-driven target lesion revascularization, and definite stent thrombosis. Complete clinical follow-up information at 2-year was obtained for all patients. The mean age was 73.2±9.0 years and 155 patients (61.5%) were male. Cumulative 2-year incidence of MACE (cardiac death, myocardial infarction, clinically-driven target lesion revascularization and definite stent thrombosis) was 20.3% (7.0%, 2.1%, 18.1% and 2.1%, respectively). Predictors of MACE were presenting with acute coronary syndrome (hazard ratio [HR]: 3.80, 95% confidence interval [CI]: 1.29-11.2, P=0.02), hemodialysis (HR: 1.93, 95% CI: 1.04-3.56, P=0.04) and previous coronary artery bypass graft (HR: 2.26, 95% CI: 1.02-5.00, P=0.045). PCI for calcified lesions requiring rotational atherectomy is still challenging even in the era of newer-generation DES.

  9. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  10. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: The PLUS-ONE first-in-man study

    International Nuclear Information System (INIS)

    Calderas, Carlos; Condado, Jose Francisco; Condado, Jose Antonio; Flores, Alejandra; Mueller, Amy; Thomas, Jack; Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa; Fitzgerald, Peter

    2014-01-01

    Background: The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol–gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. Methods: A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18 mm, n = 30) or group B (8 μg/18 mm, n = 30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Results: Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P = 1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30 mm and 0.34 ± 0.20 mm P = .773). Conclusions: In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol–gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year

  11. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: the PLUS-ONE first-in-man study.

    Science.gov (United States)

    Calderas, Carlos; Condado, Jose Francisco; Condado, Jose Antonio; Flores, Alejandra; Mueller, Amy; Thomas, Jack; Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa; Fitzgerald, Peter

    2014-01-01

    The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol-gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18mm, n=30) or group B (8 μg/18mm, n=30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P=1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30mm and 0.34 ± 0.20mm P=.773). In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol-gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year. © 2014.

  12. Safety and efficacy of low-dose paclitaxel utilizing the cobra-P drug-eluting stent system with a novel biodegradable coating in de novo coronary lesions: The PLUS-ONE first-in-man study

    Energy Technology Data Exchange (ETDEWEB)

    Calderas, Carlos [Instituto de Clinicas Urologia Tamanaco, Caracas (Venezuela, Bolivarian Republic of); Condado, Jose Francisco; Condado, Jose Antonio [Hospital Centro Medico de Caracas y Hospital Miguel Perez Carreno, Caracas (Venezuela, Bolivarian Republic of); Flores, Alejandra [Instituto de Clinicas Urologia Tamanaco, Caracas (Venezuela, Bolivarian Republic of); Mueller, Amy; Thomas, Jack [Medlogics Device Corporation, Santa Rosa, CA (United States); Nakatani, Daisaku; Honda, Yasuhiro; Waseda, Katsuhisa [Stanford University, Stanford, CA (United States); Fitzgerald, Peter, E-mail: crci-cvmed@stanford.edu [Stanford University, Stanford, CA (United States)

    2014-01-15

    Background: The Cobra-P drug-eluting stent (DES) system consists of cobalt chromium alloy with bio-absorbable siloxane sol–gel matrix coating that elutes low dose paclitaxel within 6 months. The aim of this first-in-man trial was to evaluate the safety and performance of 2 doses of the Cobra-P DES. Methods: A total of 60 lesions (54 patients) were sequentially assigned to 2 different paclitaxel doses: group A (3.7 μg/18 mm, n = 30) or group B (8 μg/18 mm, n = 30). The primary endpoint was MACE at 4 months defined as cardiac death, myocardial infarction, and target lesion revascularization. Results: Patient and lesion characteristics were matched between the 2 groups except for male sex. MACE at 4 months was 3.3% and 0% respectively (P = 1.000) and at 1-year follow-up remained unchanged. In-stent late loss at 4 months was similar in both groups (0.36 ± 0.30 mm and 0.34 ± 0.20 mm P = .773). Conclusions: In this FIM study, implantation of the Cobra-P low dose paclitaxel-eluting stent with a bioabsorbable sol–gel coating was proven to be feasible and safe. Moderate neointimal proliferation was observed as well as an acceptable MACE rate up to 1 year.

  13. First-generation versus second-generation drug-eluting stents in current clinical practice: updated evidence from a comprehensive meta-analysis of randomised clinical trials comprising 31 379 patients

    NARCIS (Netherlands)

    Navarese, E.P.; Kowalewski, M.; Kandzari, D.; Lansky, A.; Gorny, B.; Koltowski, L.; Waksman, R.; Berti, S.; Musumeci, G.; Limbruno, U.; Schaaf, R.J. van der; Kelm, M.; Kubica, J.; Suryapranata, H.

    2014-01-01

    BACKGROUND: First-generation drug-eluting stents (DES) have become the most widely used devices worldwide for management of coronary artery disease. As remote follow-up data were becoming available, concerns emerged in regard to their long-term safety. Second-generation DES were designed to overcome

  14. Red blood cell distribution width and long-term outcome in patients undergoing percutaneous coronary intervention in the drug-eluting stenting era: a two-year cohort study.

    Science.gov (United States)

    Yao, Hai-Mu; Sun, Tong-Wen; Zhang, Xiao-Juan; Shen, De-Liang; Du, You-You; Wan, You-Dong; Zhang, Jin-Ying; Li, Ling; Zhao, Luo-Sha

    2014-01-01

    Previous studies suggest the higher the red blood cell distribution width (RDW) the greater the risk of mortality in patients with coronary artery disease (CAD). However, the relationship between RDW and long-term outcome in CAD patients undergoing percutaneous coronary intervention (PCI) with a drug-eluting stent (DES) remains unclear. This study was designed to evaluate the long-term effect of RDW in patients treated with drug-eluting stent for CAD. In total of 2169 non-anemic patients (1468 men, mean age 60.2 ± 10.9 years) with CAD who had undergone successful PCI and had at least one drug-eluting stent were included in this study. Patients were grouped according to their baseline RDW: Quartile 1 (RDW<12.27%), Quartile 2 (12.27% ≤ RDW <13%), Quartile 3 (13% ≤ RDW<13.5%), and Quartile 4 (RDW ≥ 13.5). The incidence of in-hospital mortality and death or myocardial infarction was significantly higher in Quartiles 3 and 4 compared with Quartile 1 (P<0.05). After a follow-up of 29 months, the incidence of all-cause death and stent thrombosis in Quartile 4 was higher than in Quartiles 1, 2, and 3 (P<0.05). The incidence of death/myocardial infarction/stroke and cardiac death in Quartile 4 was higher than in Quartiles 1 and 2 (P<0.05). Multivariate Cox regression analysis showed that RDW was an independent predictor of all-cause death (hazard ratio (HR) = 1.37, 95% confidence interval (CI) = 1.15-1.62, P<0.001) and outcomes of death/myocardial infarction/stroke (HR = 1.21, 95% CI = 1.04-1.39, P = 0.013). The cumulative survival rate of Quartile 4 was lower than that of Quartiles 1, 2, and 3 (P<0.05). High RDW is an independent predictor of long-term adverse clinical outcomes in non-anemic patients with CAD treated with DES.

  15. Red blood cell distribution width and long-term outcome in patients undergoing percutaneous coronary intervention in the drug-eluting stenting era: a two-year cohort study.

    Directory of Open Access Journals (Sweden)

    Hai-Mu Yao

    Full Text Available BACKGROUND: Previous studies suggest the higher the red blood cell distribution width (RDW the greater the risk of mortality in patients with coronary artery disease (CAD. However, the relationship between RDW and long-term outcome in CAD patients undergoing percutaneous coronary intervention (PCI with a drug-eluting stent (DES remains unclear. This study was designed to evaluate the long-term effect of RDW in patients treated with drug-eluting stent for CAD. METHODS: In total of 2169 non-anemic patients (1468 men, mean age 60.2 ± 10.9 years with CAD who had undergone successful PCI and had at least one drug-eluting stent were included in this study. Patients were grouped according to their baseline RDW: Quartile 1 (RDW<12.27%, Quartile 2 (12.27% ≤ RDW <13%, Quartile 3 (13% ≤ RDW<13.5%, and Quartile 4 (RDW ≥ 13.5. RESULTS: The incidence of in-hospital mortality and death or myocardial infarction was significantly higher in Quartiles 3 and 4 compared with Quartile 1 (P<0.05. After a follow-up of 29 months, the incidence of all-cause death and stent thrombosis in Quartile 4 was higher than in Quartiles 1, 2, and 3 (P<0.05. The incidence of death/myocardial infarction/stroke and cardiac death in Quartile 4 was higher than in Quartiles 1 and 2 (P<0.05. Multivariate Cox regression analysis showed that RDW was an independent predictor of all-cause death (hazard ratio (HR = 1.37, 95% confidence interval (CI = 1.15-1.62, P<0.001 and outcomes of death/myocardial infarction/stroke (HR = 1.21, 95% CI = 1.04-1.39, P = 0.013. The cumulative survival rate of Quartile 4 was lower than that of Quartiles 1, 2, and 3 (P<0.05. CONCLUSION: High RDW is an independent predictor of long-term adverse clinical outcomes in non-anemic patients with CAD treated with DES.

  16. Five-year outcome after implantation of zotarolimus- and everolimus-eluting stents in randomized trial participants and nonenrolled eligible patients : A secondary analysis of a randomized clinical trial

    NARCIS (Netherlands)

    Von Birgelen, Clemens; Van Der Heijden, Liefke C.; Basalus, Mounir Welson Zakhary; Kok, Marlies M.; Sen, Hanim; Louwerenburg, Hans W.; van Houwelingen, Gert K.; Stoel, Martin G.; de Man, Frits H.A.F.; Linssen, Gerard C.M.; Tandjung, Kenneth; Doggen, Carine J.M.; Van Der Palen, Job; Löwik, Marije M.

    2017-01-01

    IMPORTANCE: Long-term follow-up after a clinical trial of 2 often-used, newer-generation drug-eluting stents (DESs) in a broad patient population is of interest. Comprehensive long-term outcome of eligible nonenrolled patients has never been reported. OBJECTIVE: To assess 5-year safety and efficacy

  17. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  18. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  19. Evaluación económica del stent medicado vs. convencional para pacientes con infarto agudo de miocardio con elevación del ST en Colombia

    Directory of Open Access Journals (Sweden)

    Mateo Ceballos

    2014-11-01

    Conclusiones: El stent medicado con sirolimus no es costo-efectivo para pacientes con infarto agudo de miocardio con elevación del ST en Colombia. Se recomienda mayor investigación futura sobre la probabilidad de muerte y trombosis muy tardía del stent, así como en subgrupos específicos de pacientes y stents medicados de segunda generación.

  20. Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis

    Science.gov (United States)

    Zarogoulidis, Paul; Darwiche, Kaid; Tsakiridis, Kosmas; Teschler, Helmut; Yarmus, Lonny; Zarogoulidis, Konstantinos; Freitag, Lutz

    2014-01-01

    Tracheal stenosis due to either benign or malignant disease is a situation that the pulmonary physicians and thoracic surgeons have to cope in their everyday clinical practice. In the case where tracheal stenosis is caused due to malignancy mini-interventional interventions with laser, apc, cryoprobe, balloon dilation or with combination of more than one equipment and technique can be used. On the other hand, in the case of a benign disease such as; tracheomalacia the clinician can immediately upon diagnosis proceed to the stent placement. In both situations however; it has been observed that the stents induce formation of granuloma tissue in both or one end of the stent. Therefore a frequent evaluation of the patient is necessary, taking also into account the nature of the primary disease. Evaluation methodologies identifying different types and extent of the trachea stenosis have been previously published. However; we still do not have an effective adjuvant therapy to prevent granuloma tissue formation or prolong already treated granuloma lesions. There have been proposed many mechanisms which induce the abnormal growth of the local tissue, such as; local pressure, local stress, inflammation and vascular endothelial growth factor overexpression. Immunomodulatory agents inhibiting the mTOR pathway are capable of inhibiting the inflammatory cascade locally. In the current mini-review we will try to present the current knowledge of drug eluting stents inhibiting the mTOR pathway and propose a future application of these stents as a local anti-proliferative treatment. PMID:24454525

  1. Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis.

    Science.gov (United States)

    Zarogoulidis, Paul; Darwiche, Kaid; Tsakiridis, Kosmas; Teschler, Helmut; Yarmus, Lonny; Zarogoulidis, Konstantinos; Freitag, Lutz

    2013-08-26

    Tracheal stenosis due to either benign or malignant disease is a situation that the pulmonary physicians and thoracic surgeons have to cope in their everyday clinical practice. In the case where tracheal stenosis is caused due to malignancy mini-interventional interventions with laser, apc, cryoprobe, balloon dilation or with combination of more than one equipment and technique can be used. On the other hand, in the case of a benign disease such as; tracheomalacia the clinician can immediately upon diagnosis proceed to the stent placement. In both situations however; it has been observed that the stents induce formation of granuloma tissue in both or one end of the stent. Therefore a frequent evaluation of the patient is necessary, taking also into account the nature of the primary disease. Evaluation methodologies identifying different types and extent of the trachea stenosis have been previously published. However; we still do not have an effective adjuvant therapy to prevent granuloma tissue formation or prolong already treated granuloma lesions. There have been proposed many mechanisms which induce the abnormal growth of the local tissue, such as; local pressure, local stress, inflammation and vascular endothelial growth factor overexpression. Immunomodulatory agents inhibiting the mTOR pathway are capable of inhibiting the inflammatory cascade locally. In the current mini-review we will try to present the current knowledge of drug eluting stents inhibiting the mTOR pathway and propose a future application of these stents as a local anti-proliferative treatment.

  2. Polymer-free Drug-Coated Coronary Stents in Patients at High Bleeding Risk

    DEFF Research Database (Denmark)

    Urban, Philip; Meredith, Ian T; Abizaid, Alexandre

    2015-01-01

    BACKGROUND: Patients at high risk for bleeding who undergo percutaneous coronary intervention (PCI) often receive bare-metal stents followed by 1 month of dual antiplatelet therapy. We studied a polymer-free and carrier-free drug-coated stent that transfers umirolimus (also known as biolimus A9......), a highly lipophilic sirolimus analogue, into the vessel wall over a period of 1 month. METHODS: In a randomized, double-blind trial, we compared the drug-coated stent with a very similar bare-metal stent in patients with a high risk of bleeding who underwent PCI. All patients received 1 month of dual...... ratio, 0.50; 95% CI, 0.37 to 0.69; Pbleeding who underwent PCI, a polymer-free umirolimus-coated stent was superior to a bare-metal stent with respect to the primary safety and efficacy end points when used with a 1-month course of dual antiplatelet...

  3. In-vitro release of anti-proliferative paclitaxel from novel balloon-expandable polycaprolactone stents

    International Nuclear Information System (INIS)

    Liu, Shih-Jung; Hsiao, Chao-Ying; Chen, Jan-Kan; Liu, Kuo-Sheng; Lee, Cheng-Hung

    2011-01-01

    This report investigated the in-vitro release characteristics of paclitaxel from novel balloon-expandable polycaprolactone stents. Polycaprolactone stents were first manufactured by a lab-made micro-injection molding machine. Paclitaxel and polylactide-polyglycolide (PLGA) copolymer were dissolved in acetonitrile and were coated onto the surface of the stents by a spray coating device, which was designed and built especially for this study. An elution method was utilized to characterize the in-vitro release characteristics of paclitaxel. The high performance liquid chromatography (HPLC) analysis showed that biodegradable stents could provide sustained release of paclitaxel for more than 70 days. Various process parameters that controlled the release rate of paclitaxel were studied. The experimental results suggested that the total period of drug release could be prolonged by adopting 75:25 PLGA copolymers, employing multi-layer coatings, and increasing the drug loading. In addition, the effectiveness of eluted paclitaxel on cell behavior was examined. The results showed that the eluted drug could effectively inhibit the proliferation of smooth muscle cells. - Research Highlights: → We investigate the in-vitro release characteristics of paclitaxel from polycaprolactone stents. → Biodegradable stents provide sustained release of paclitaxel for more than 70 days. → The eluted drug effectively inhibits the proliferation of smooth muscle cells.

  4. Percutaneous coronary intervention with second-generation drug-eluting stent versus bare-metal stent: Systematic review and cost-benefit analysis.

    Science.gov (United States)

    Poder, Thomas G; Erraji, Jihane; Coulibaly, Lucien P; Koffi, Kouamé

    2017-01-01

    Drug-eluting stents (DESs) were considered as ground-breaking technology promising to eradicate restenosis and the necessity to perform multiple revascularization procedures subsequent to percutaneous coronary intervention. Soon after DESs were released on the market, however, there were reports of a potential increase in mortality and of early or late thrombosis. In addition, DESs are far more expensive than bare-metal stents (BMSs), which has led to their limited use in many countries. The technology has improved over the last few years with the second generation of DESs (DES-2). Moreover, costs have come down and an improved safety profile with decreased thrombosis has been reported. Perform a cost-benefit analysis of DES-2s versus BMSs in the context of a publicly funded university hospital in Quebec, Canada. A systematic review of meta-analyses was conducted between 2012 and 2016 to extract data on clinical effectiveness. The clinical outcome of interest for the cost-benefit analysis was target-vessel revascularization (TVR). Cost units are those used in the Quebec health-care system. The cost-benefit analysis was based on a 2-year perspective. Deterministic and stochastic models (discrete-event simulation) were used, and various risk factors of reintervention were considered. DES-2s are much more effective than BMSs with respect to TVR rate ratio (i.e., 0.29 to 0.62 in more recent meta-analyses). DES-2s seem to cause fewer deaths and in-stent thrombosis than BMSs, but results are rarely significant, with the exception of the cobalt-chromium everolimus DES. The rate ratio of myocardial infraction is systematically in favor of DES-2s and very often significant. Despite the higher cost of DES-2s, fewer reinterventions can lead to huge savings (i.e., -$479 to -$769 per patient). Moreover, the higher a patient's risk of reintervention, the higher the savings associated with the use of DES-2s. Despite the higher purchase cost of DES-2s compared to BMSs

  5. Efficacy and safety of sirolimus in lymphangioleiomyomatosis.

    Science.gov (United States)

    McCormack, Francis X; Inoue, Yoshikazu; Moss, Joel; Singer, Lianne G; Strange, Charlie; Nakata, Koh; Barker, Alan F; Chapman, Jeffrey T; Brantly, Mark L; Stocks, James M; Brown, Kevin K; Lynch, Joseph P; Goldberg, Hilary J; Young, Lisa R; Kinder, Brent W; Downey, Gregory P; Sullivan, Eugene J; Colby, Thomas V; McKay, Roy T; Cohen, Marsha M; Korbee, Leslie; Taveira-DaSilva, Angelo M; Lee, Hye-Seung; Krischer, Jeffrey P; Trapnell, Bruce C

    2011-04-28

    Lymphangioleiomyomatosis (LAM) is a progressive, cystic lung disease in women; it is associated with inappropriate activation of mammalian target of rapamycin (mTOR) signaling, which regulates cellular growth and lymphangiogenesis. Sirolimus (also called rapamycin) inhibits mTOR and has shown promise in phase 1-2 trials involving patients with LAM. We conducted a two-stage trial of sirolimus involving 89 patients with LAM who had moderate lung impairment--a 12-month randomized, double-blind comparison of sirolimus with placebo, followed by a 12-month observation period. The primary end point was the difference between the groups in the rate of change (slope) in forced expiratory volume in 1 second (FEV(1)). During the treatment period, the FEV(1) slope was -12±2 ml per month in the placebo group (43 patients) and 1±2 ml per month in the sirolimus group (46 patients) (Plife and functional performance. There was no significant between-group difference in this interval in the change in 6-minute walk distance or diffusing capacity of the lung for carbon monoxide. After discontinuation of sirolimus, the decline in lung function resumed in the sirolimus group and paralleled that in the placebo group. Adverse events were more common with sirolimus, but the frequency of serious adverse events did not differ significantly between the groups. In patients with LAM, sirolimus stabilized lung function, reduced serum VEGF-D levels, and was associated with a reduction in symptoms and improvement in quality of life. Therapy with sirolimus may be useful in selected patients with LAM. (Funded by the National Institutes of Health and others; MILES ClinicalTrials.gov number, NCT00414648.).

  6. A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent: The SPIRIT first trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Ong, Andrew T. L.; Piek, Jan J.; Neumann, Franz-Josef; van der Giessen, Willem J.; Wiemer, Marcus; Zeiher, Andreas; Grube, Eberhard; Haase, Jürgen; Thuesen, Leif; Hamm, Christian; Otto-Terlouw, Patricia C.

    2005-01-01

    Background: Everolimus is a sirolimus analogue with similar efficacy in animal models, and has been previously successfully tested in humans using an erodable polymer.Methods: This first-in-man single blind multi-centre randomized controlled trial assessed the safety and efficacy of everolimus

  7. Novel management strategy for coronary steal syndrome: case report of occlusion of a LIMA graft side branch with a combination of drug-eluting and covered-stent deployment.

    LENUS (Irish Health Repository)

    Hynes, Brian G

    2009-11-01

    We report a novel percutaneous therapeutic approach to the management of suspected coronary artery steal syndrome resulting from a large side branch of the left internal mammary artery bypass graft, using a combination of coated and drug-eluting stents. We demonstrate the feasibility and long-term efficacy of this strategy in a case report.

  8. Acute sirolimus overdose: a multicenter case series.

    Directory of Open Access Journals (Sweden)

    Alessandro Ceschi

    Full Text Available There are few data relating to sirolimus overdose in the medical literature. Our objectives were to describe all cases of overdose with sirolimus reported to Swiss, German and Austrian Poisons Centres between 2002-2013.An observational case-series analysis was performed to determine circumstances, magnitude, management and outcome of sirolimus overdose.Five cases of acute sirolimus overdose were reported--three in young children and two in adults. Four were accidental and one was with suicidal intent. Two patients developed symptoms probably related to sirolimus overdose: mild elevation of alkaline phosphatase, fever and gastroenteritis in a 2.5-year-old male who ingested 3 mg, and mild changes in total cholesterol in an 18-year-old female after ingestion of 103 mg. None of these events were life-threatening. Serial blood concentration measurements were performed starting 24 h after ingestion of 103 mg in a single case, and these followed a similar pharmacokinetic time-course to measurements taken after dosing in the therapeutic range.Acute sirolimus overdose occurred accidentally in the majority of cases. Even large overdoses appeared to be well-tolerated, however children might be at greater risk of developing complications. Further study of sirolimus overdose is needed.

  9. Six-Month Clinical and Angiographic Results of Paclitaxel Eluting Simpax Stent

    Directory of Open Access Journals (Sweden)

    Mehmet Muhsin Türkmen

    2012-08-01

    Full Text Available Introduction: We aimed to evaluate the safety and efficacy of the simpax stent in the treatmentof different patient groups.Patients and Methods: Forty-five patients were treated with the simpax stent. Of these patients,23 patients gave consent for six months of follow-up by quantitative coronary angiography (QSAand six patients were evaluated by exercise electrocardiographic test. Only the patients havinglesions with stenosis > 50% of diameter and lengths > 16 mm with reference diameters < 2.75mm were included.Results: The device success rate was 100% and procedure success rate was 97.7%. The meanstent length was 24.6 ± 7.3 mm and stent size was 2.54 ± 0.24 mm. The overall six months incidenceof major adverse cardiac events (MACE was 8.8%. MACE was consisted of two casesof non-Q wave myocardial infarction and two cases of repeated revascularization of the targetlesion. MACE rate was higher in chronic total occlusion (CTO group than non-CTO group (respectively33.3% and 5.1. Also when compared to stent size, MACE rate was 25% in < 2.5 mm,0% ≥ 2.5 mm. The QSA results at six months showed in-stent late lumen loss witha diameter of0.25 ± 0.15 mm in 17 patients.Conclusion: The six month results in this study demonsrated excellent procedural and devicesuccess. Simpax stent was associated with a low in-stent late lumen loss. Also this study showedsimpax stent was a safe and effective device in non-CTO group with stent size ≥ 2.5 mm.

  10. 1-year clinical outcomes of diabetic patients treated with everolimus-eluting bioresorbable vascular scaffolds: a pooled analysis of the ABSORB and the SPIRIT trials.

    Science.gov (United States)

    Muramatsu, Takashi; Onuma, Yoshinobu; van Geuns, Robert-Jan; Chevalier, Bernard; Patel, Tejas M; Seth, Ashok; Diletti, Roberto; García-García, Hector M; Dorange, Cécile C; Veldhof, Susan; Cheong, Wai-Fung; Ozaki, Yukio; Whitbourn, Robert; Bartorelli, Antonio; Stone, Gregg W; Abizaid, Alexandre; Serruys, Patrick W

    2014-05-01

    The aim of this study was to evaluate 1-year clinical outcomes of diabetic patients treated with the Absorb bioresorbable vascular scaffold (BVS). Clinical outcomes of diabetic patients after BVS implantation have been unreported. This study included 101 patients in the ABSORB Cohort B trial and the first consecutive 450 patients with 1 year of follow-up in the ABSORB EXTEND trial. A total of 136 diabetic patients were compared with 415 nondiabetic patients. In addition, 882 diabetic patients treated with everolimus-eluting metal stents (EES) in pooled data from the SPIRIT trials (SPIRIT FIRST [Clinical Trial of the Abbott Vascular XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT II [A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System], SPIRIT III [Clinical Trial of the XIENCE V Everolimus Eluting Coronary Stent System (EECSS)], SPIRIT IV Clinical Trial [Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System]) were used for the comparison by applying propensity score matching. The primary endpoint was a device-oriented composite endpoint (DoCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization at 1-year follow-up. The cumulative incidence of DoCE did not differ between diabetic and nondiabetic patients treated with the BVS (3.7% vs. 5.1%, p = 0.64). Diabetic patients treated with the BVS had a similar incidence of the DoCE compared with diabetic patients treated with EES in the matched study group (3.9% for the BVS vs. 6.4% for EES, p = 0.38). There were no differences in the incidence of definite or probable scaffold/stent thrombosis (0.7% for both diabetic and nondiabetic patients with the BVS; 1.0% for diabetic patients with the BVS vs. 1.7% for diabetic patients with EES in the matched study group). In the present analyses, diabetic patients treated with the BVS showed similar rates of DoCEs compared with nondiabetic patients treated with the BVS and

  11. Rotational atherectomy before paclitaxel-eluting stent implantation in complex calcified coronary lesions: Two-year clinical outcome of the randomized ROTAXUS trial.

    Science.gov (United States)

    de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-03-01

    In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.

  12. Análisis Costo Efectividad del Stent Farmacológico V/S Stent no Farmacológico en Cardiopatía Isquémica en Chile.

    Science.gov (United States)

    De la Puente, Catherine; Vallejos, Carlos; Velásquez, Mónica; Soto, David; Orellana, Juan

    2012-12-01

    To evaluate and compare the costs and effectiveness of two alternative stent, drug eluting stent (SF) and bare metal stent (SNF). Cost-utility analysis based on a Markov model using data from a cohort study of Hospital Las Higueras of Talcahuano, Chile. The effectiveness measure was the rate of restenosis and the time of restenosis. The effectiveness outcomes are expressed in quality-adjusted life years (QALY) gained. Costs are expressed in national currency 2011. The evaluation perspective was from the public heath budget. We model a cohort from age 63 to 80 years, life expectancy in Chile. Apply discount rate of 0, 3% and 6% for results and costs. Sensitivity analysis is performed according to the ranges of variability in costs, the utility values of the variables and transition between states. No differences in restenosis rates between the two stents, although there were differences in the time of restenosis. The incremental cost effectiveness ratio (ICER) no discount rate was CH$ 235.749 per QALY gained when using drug-eluting stent, the value below the equivalent of 1 Gross Domestic Product (PIB) per capita for 2011 in Chile. The drug-eluting stent (SF) is cost effective compared to bare metal stent (SNF). The ICER is not affected by the sensitivity analysis (variability of cost, utility ranges used, probability of restenosis). Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials.

    Science.gov (United States)

    Kheiri, Babikir; Osman, Mohammed; Abdalla, Ahmed; Ahmed, Sahar; Bachuwa, Ghassan; Hassan, Mustafa

    2018-05-11

    The use of drug-eluting stents (DES) vs bare-metal stents (BMS) in saphenous vein graft (SVG) lesions remains controversial. We conducted a meta-analysis of all randomized clinical trials comparing the outcomes of DES with BMS in SVG percutaneous coronary interventions. A search of PubMed, Embase, the Cochrane Register of Controlled Trials, and Clinicaltrials.gov was performed for all randomized clinical trials. We evaluated the short- and long-term clinical outcomes of the following: all-cause mortality, major adverse cardiovascular events (MACE), definite/probable stent thrombosis, target lesion revascularization (TLR), and target-vessel revascularization (TVR). From a total of 1582 patients in 6 randomized clinical trials, 797 had DES and 785 had BMS. Patients with DES had lower short-term MACE, TLR, and TVR in comparison with BMS (odds ratio [OR]: 0.56, 95% confidence interval [CI]: 0.35-0.91, P = 0.02; OR: 0.43, 95% CI: 0.19-0.99, P = 0.05; and OR: 0.45, 95% CI: 0.22-0.95, P = 0.04, respectively). However, there were no different outcomes for all-cause mortality (P = 0.63) or stent thrombosis (P = 0.21). With long-term follow-up, there were no significant reductions of MACE (P = 0.20), TLR (P = 0.57), TVR (P = 0.07), all-cause mortality (P = 0.29), and stent thrombosis (P = 0.76). The use of DES in SVG lesions was associated with lower short-term MACE, TLR, and TVR in comparison with BMS. However, there were no significant differences with long-term follow-up. © 2018 Wiley Periodicals, Inc.

  14. Sirolimus use and cancer incidence among US kidney transplant recipients.

    Science.gov (United States)

    Yanik, E L; Gustafson, S K; Kasiske, B L; Israni, A K; Snyder, J J; Hess, G P; Engels, E A; Segev, D L

    2015-01-01

    Sirolimus has anti-carcinogenic properties and can be included in maintenance immunosuppressive therapy following kidney transplantation. We investigated sirolimus effects on cancer incidence among kidney recipients. The US transplant registry was linked with 15 population-based cancer registries and national pharmacy claims. Recipients contributed sirolimus-exposed time when sirolimus claims were filled, and unexposed time when other immunosuppressant claims were filled without sirolimus. Cox regression was used to estimate associations with overall and specific cancer incidence, excluding nonmelanoma skin cancers (not captured in cancer registries). We included 32,604 kidney transplants (5687 sirolimus-exposed). Overall, cancer incidence was suggestively lower during sirolimus use (hazard ratio [HR] = 0.88, 95% confidence interval [CI] = 0.70-1.11). Prostate cancer incidence was higher during sirolimus use (HR = 1.86, 95% CI = 1.15-3.02). Incidence of other cancers was similar or lower with sirolimus use, with a 26% decrease overall (HR = 0.74, 95% CI = 0.57-0.96, excluding prostate cancer). Results were similar after adjustment for demographic and clinical characteristics. This modest association does not provide strong evidence that sirolimus prevents posttransplant cancer, but it may be advantageous among kidney recipients with high cancer risk. Increased prostate cancer diagnoses may result from sirolimus effects on screen detection. © Copyright 2014 The American Society of Transplantation and the American Society of Transplant Surgeons.

  15. Palmoplantar peeling secondary to sirolimus therapy.

    Science.gov (United States)

    Liu, L S; McNiff, J M; Colegio, O R

    2014-01-01

    Sirolimus (rapamycin) is an immunosuppressive agent commonly used in transplant recipients. Although sirolimus has less renal toxicity than calcineurin inhibitors, its use has been limited by its side effects. The most common cutaneous pathologies associated with sirolimus are inflammatory acneiform eruptions, lymphedema and aphthous ulcers. We present a novel cutaneous manifestation of sirolimus therapy that limited its use in at least one transplant recipient. Upon commencing sirolimus therapy, four solid organ transplant recipients developed tender, nonpruritic palmoplantar peeling within the first month of therapy. The peeling clinically resembled a mild form of hand-foot syndrome, yet none of the patients had been treated with chemotherapeutics. Desquamation presented on the palms and soles with dry vesicles and minor peeling extending to the dorsal aspects of the hands and feet. Histologically, the lesions were noninflammatory; the epidermis showed subtle separation between keratinocytes, suggesting either spongiosis or a defect in intercellular adhesion. One patient opted to discontinue treatment because of the tenderness associated with the palmoplantar peeling, which resulted in complete resolution within 2 weeks. © Copyright 2013 The American Society of Transplantation and the American Society of Transplant Surgeons.

  16. Fractura de stent sirolimus: una causa de restenosis tardía

    Directory of Open Access Journals (Sweden)

    William Amaya

    2013-12-01

    Full Text Available El primer caso de fractura de stent farmacológico en arterias coronarias fue publicado en 2004, y aunque es un evento infrecuente, las implicaciones diagnósticas y terapéuticas siguen siendo un reto. Se presenta el caso de un paciente de género masculino, de 49 años de edad, portador de dos stents medicados, con antedecedente de nuevo evento coronario y diagnóstico de fractura de dichos dispositivos a través de cateterismo.

  17. Sirolimus therapy to halt the progression of ADPKD.

    Science.gov (United States)

    Perico, Norberto; Antiga, Luca; Caroli, Anna; Ruggenenti, Piero; Fasolini, Giorgio; Cafaro, Mariateresa; Ondei, Patrizia; Rubis, Nadia; Diadei, Olimpia; Gherardi, Giulia; Prandini, Silvia; Panozo, Andrea; Bravo, Rodolfo Flores; Carminati, Sergio; De Leon, Felipe Rodriguez; Gaspari, Flavio; Cortinovis, Monica; Motterlini, Nicola; Ene-Iordache, Bogdan; Remuzzi, Andrea; Remuzzi, Giuseppe

    2010-06-01

    Activation of mammalian target of rapamycin (mTOR) pathways may contribute to uncontrolled cell proliferation and secondary cyst growth in patients with autosomal dominant polycystic kidney disease (ADPKD). To assess the effects of mTOR inhibition on disease progression, we performed a randomized, crossover study (The SIRENA Study) comparing a 6-month treatment with sirolimus or conventional therapy alone on the growth of kidney volume and its compartments in 21 patients with ADPKD and GFR>or=40 ml/min per 1.73 m2. In 10 of the 15 patients who completed the study, aphthous stomatitis complicated sirolimus treatment but was effectively controlled by topical therapy. Compared with pretreatment, posttreatment mean total kidney volume increased less on sirolimus (46+/-81 ml; P=0.047) than on conventional therapy (70+/-72 ml; P=0.002), but we did not detect a difference between the two treatments (P=0.45). Cyst volume was stable on sirolimus and increased by 55+/-75 ml (P=0.013) on conventional therapy, whereas parenchymal volume increased by 26+/-30 ml (P=0.005) on sirolimus and was stable on conventional therapy. Percentage changes in cyst and parenchyma volumes were significantly different between the two treatment periods. Sirolimus had no appreciable effects on intermediate volume and GFR. Albuminuria and proteinuria marginally but significantly increased during sirolimus treatment. In summary, sirolimus halted cyst growth and increased parenchymal volume in patients with ADPKD. Whether these effects translate into improved long-term outcomes requires further investigation.

  18. Comparison of Long-Term Clinical Outcomes of Lesions Exhibiting Focal and Segmental Peri-Stent Contrast Staining.

    Science.gov (United States)

    Tokuda, Takahiro; Yamawaki, Masahiro; Takahara, Mitsuyohi; Mori, Shinsuke; Makino, Kenji; Honda, Yosuke; Takafuji, Hiroya; Takama, Takuro; Tsutsumi, Masakazu; Sakamoto, Yasunari; Takimura, Hideyuki; Kobayashi, Norihiro; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki

    2016-03-18

    Peri-stent contrast staining (PSS) after metallic drug-eluting stent deployment is associated with target lesion revascularization and very late stent thrombosis. However, the type of PSS that influences the clinical outcomes is unknown. Therefore, we aimed to reveal which PSS type was influencing clinical outcomes. This study included 5580 de novo lesions of 4405 patients who were implanted with a first- or second-generation drug-eluting stent and who were evaluated using follow-up angiography within 12 months after stent implantation. We compared the clinical outcomes of patients divided into focal PSS and segmental PSS groups for 6 years after stent implantation. Total PSS was observed in 97 lesions (2.2%), of which 42 and 55 lesions were focal and segmental PSS, respectively. Baseline characteristics were similar between groups, except for intraoperative chronic total occlusion (segmental PSS=47.3% versus focal PSS=11.9%, P=0.0001). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent (83.6% versus 16.4%, P=0.05). The cumulative incidence of stent thrombosis in the 6 years of segmental PSS group was significantly higher than that of the focal PSS group (13.9% versus 0%, P=0.04). The cumulative incidence of overall target lesion revascularization for restenosis, excluding target lesion revascularization procedures for stent thrombosis, was significantly higher in the segmental PSS group (38.0% versus 0%, P=0.01). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent and appeared to be significantly associated with target lesion revascularization and stent thrombosis. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  19. A randomised comparison of an everolimus-eluting coronary stent with a paclitaxel-eluting coronary stent:the SPIRIT II trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Ruygrok, Peter; Neuzner, Jörg; Piek, Jan J.; Seth, Ashok; Schofer, Joachim J.; Richardt, Gert; Wiemer, Marcus; Carrié, Didier; Thuesen, Leif; Boone, Els; Miquel-Herbert, Karine; Daemen, Joost

    2006-01-01

    Background: Everolimus has been successfully tested in humans using both an erodable and a durable polymer in small previous studies.Methods: This single blind multi-centre non-inferiority randomised (3:1) controlled trial evaluated the safety and performance of the XIENCE V Everolimus Eluting

  20. [Coronary stents: 30 years of medical progress].

    Science.gov (United States)

    Silvain, Johanne; Cayla, Guillaume; Collet, Jean-Philippe; Fargeot, Catherine; Montalescot, Gilles

    2014-03-01

    The history of interventional cardiology has been marked by several technologic revolutions since the late 1970s. The first key step was the use of inflatable balloon angioplasty as an alternative to CABG surgery for coronary revascularization, followed by intracoronary delivery of bare metal stent (BMS) and drug eluting stents (DES) to drastically reduce intracoronary restenosis observed with BMS. Improved stents platforms and polymers (absorbable or biocompatible) led to a dramatic reduction in the rate of late stent thrombosis. Self-expanding stents are now available to improve stent a position especially in acute myocardial infarction. The emergence of new fully bioabsorbable stents that can be combined with antiproliferative drugs is the ongoing revolution. A new generation of stents is continuously improving and likely to become the ideal stent for coronary revascularization in the near future. © 2014 médecine/sciences – Inserm.

  1. Prevalence and impact of high platelet reactivity in chronic kidney disease: results from the Assessment of Dual Antiplatelet Therapy with Drug-Eluting Stents registry.

    Science.gov (United States)

    Baber, Usman; Mehran, Roxana; Kirtane, Ajay J; Gurbel, Paul A; Christodoulidis, Georgios; Maehara, Akiko; Witzenbichler, Bernhard; Weisz, Giora; Rinaldi, Michael J; Metzger, D Christopher; Henry, Timothy D; Cox, David A; Duffy, Peter L; Mazzaferri, Ernest L; Xu, Ke; Parise, Helen; Brodie, Bruce R; Stuckey, Thomas D; Stone, Gregg W

    2015-06-01

    Chronic kidney disease (CKD) is associated with increased rates of adverse events after percutaneous coronary intervention. We sought to determine the impact of CKD on platelet reactivity in clopidogrel-treated patients and whether high platelet reactivity (HPR) confers a similar or differential risk for adverse events among patients with CKD and non-CKD. We performed a post hoc analysis of the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) registry, which included 8582 patients undergoing percutaneous coronary intervention with drug-eluting stents and platelet function testing using the VerifyNow assay. We compared HPR and its impact on ischemic and bleeding events >2 years among patients with CKD and non-CKD. Patients with CKD (n=1367) were older, more often female, diabetic, and had lower ejection fraction compared with their non-CKD counterparts (n=7043). Although HPR prevalence increased with worsening renal function in unadjusted analyses, these associations were no longer present after adjustment. Major adverse cardiac event rates at 2 years among those without CKD or HPR, HPR alone, CKD alone, and both CKD and HPR were 9.0%, 11.2%, 13.3%, and 17.5%, respectively (Pimpact of HPR on ischemic and bleeding events is similar irrespective of CKD status. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2015 American Heart Association, Inc.

  2. Prevention of stent thrombosis: challenges and solutions

    Science.gov (United States)

    Reejhsinghani, Risheen; Lotfi, Amir S

    2015-01-01

    Stent thrombosis is an uncommon but serious complication which carries with it significant mortality and morbidity. This review analyzes the entity of stent thrombosis from a historical and clinical perspective, and chronicles the evolution of this condition through the various generations of stent development, from bare metal to first-generation, second-generation, and third-generation drug-eluting stents. It also delineates the specific risk factors associated with stent thrombosis and comprehensively examines the literature related to each of these risks. Finally, it highlights the preventative strategies that can be garnered from the existing data, and concludes that a multifactorial approach is necessary to combat the occurrence of stent thrombosis, with higher risk groups, such as patients with ST segment elevation myocardial infarction, meriting further research. PMID:25657588

  3. Biodegradable, elastomeric coatings with controlled anti-proliferative agent release for magnesium-based cardiovascular stents.

    Science.gov (United States)

    Gu, Xinzhu; Mao, Zhongwei; Ye, Sang-Ho; Koo, Youngmi; Yun, Yeoheung; Tiasha, Tarannum R; Shanov, Vesselin; Wagner, William R

    2016-08-01

    Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Risk of Adverse Cardiac and Bleeding Events Following Cardiac and Noncardiac Surgery in Patients With Coronary Stent: How Important Is the Interplay Between Stent Type and Time From Stenting to Surgery?

    Science.gov (United States)

    Saia, Francesco; Belotti, Laura Maria Beatrice; Guastaroba, Paolo; Berardini, Alessandra; Rossini, Roberta; Musumeci, Giuseppe; Tarantini, Giuseppe; Campo, Gianluca; Guiducci, Vincenzo; Tarantino, Fabio; Menozzi, Alberto; Varani, Elisabetta; Santarelli, Andrea; Tondi, Stefano; De Palma, Rossana; Rapezzi, Claudio; Marzocchi, Antonio

    2016-01-01

    Epidemiology and consequences of surgery in patients with coronary stents are not clearly defined, as well as the impact of different stent types in relationship with timing of surgery. Among 39 362 patients with previous coronary stenting enrolled in a multicenter prospective registry and followed for 5 years, 13 128 patients underwent 17 226 surgical procedures. The cumulative incidence of surgery at 30 days, 6 months, 1 year, and 5 years was 3.6%, 9.4%, 14.3%, and 40.0%, respectively, and of cardiac and noncardiac surgery was 0.8%, 2.1%, 2.6%, and 4.0% and 1.3%, 5.1%, 9.1%, and 31.7%, respectively. We assessed the incidence and the predictors of cardiac death, myocardial infarction, and serious bleeding event within 30 days from surgery. Cardiac death occurred in 438 patients (2.5%), myocardial infarction in 256 (1.5%), and serious bleeding event in 1099 (6.4%). Surgery increased 1.58× the risk of cardiac death during follow-up. Along with other risk factors, the interplay between stent type and time from percutaneous coronary intervention to surgery was independently associated with cardiac death/myocardial infarction. In comparison with bare-metal stent implanted >12 months before surgery, old-generation drug-eluting stent was associated with higher risk of events at any time point. Conversely, new-generation drug-eluting stent showed similar safety as bare-metal stent >12 months and between 6 and 12 months and appeared trendly safer between 0 and 6 months. Surgery is frequent in patients with coronary stents and carries a considerable risk of ischemic and bleeding events. Ischemic risk is inversely related with time from percutaneous coronary intervention to surgery and is influenced by stent type. © 2015 American Heart Association, Inc.

  5. Expert consensus (SBC/SBHCI) on the use of drug-eluting stents: recommendations of the Brazilian society of interventional cardiology/ Brazilian society of cardiology for the Brazilian public single healthcare system.

    Science.gov (United States)

    Lima, Valter C; Mattos, Luiz Alberto P; Caramori, Paulo R A; Perin, Marco A; Mangione, José A; Machado, Bruno M; Coelho, Wilson M C; Bueno, Ronaldo R L

    2006-10-01

    The authors review percutaneous coronary intervention (PCI) evolution and its growing application in myocardial revascularization for patients with coronary heart disease in Brazil and worldwide. PCI was introduced in 1977 using only the catheter balloon. Limitations of this method (acute occlusion and coronary restenosis) led to the adoption of coronary stents and more recently the advent of drug-eluting stents2, which were developed to drastically reduce restenosis rates. These developments allowed the exponential growth of percutaneous coronary intervention (PCI) procedures in Brazil which have replaced many bypass surgery procedures and have become the gold standard for the majority of symptomatic patients suffering from coronary artery disease. The preference for this procedure gained new dimensions in 2000 when the Brazilian Public Healthcare System (SUS) began reimbursing for stent procedures. This measure exemplified the importance of the Public Healthcare System's participation in incorporating medical advances and offering a high standard of cardiovascular treatment to a large portion of the Brazilian population. It is emphasized that prevention of in-stent restenosis is complex due to its unpredictable and ubiquitous occurrence. Control of this condition improves quality of life and reduces the recurrence of angina pectoris, the need to perform new revascularization procedures and hospital readmissions. The overall success of the drug-eluting stents has proven to be reliable and consistent in overcoming restenosis and has some beneficial impact for all clinical and angiographic conditions. This paper discusses the adoption and criteria for the use of drug-eluting stents in other countries as well as the recommendations established by the Brazilian Society of Interventional Cardiology for their reimbursement by SUS. The incorporation of new healthcare technology involves two distinct stages. During the first stage, the product is registered with the

  6. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  7. [Developments in percutaneous coronary intervention and coronary stents].

    Science.gov (United States)

    Simsek, C; Daemen, J; Zijlstra, F

    2014-01-01

    In The Netherlands, more than 30.000 patients undergo a percutaneous coronary intervention every year, during which a coronary stent implantation will be performed in 90% of the cases. It is estimated that more than 5 million coronary stent implantations will be performed worldwide this year. While these numbers are impressive, however, coronary stents still have as a limitation the possibility of stent thrombosis. This has been and is an important stimulus for the development of both coronary stents, from a bare metal stent via a drug eluting stent to the present-day development of bio-absorbable stents, and anti-platelet drugs,from acenocoumarol to thieropyridines. The possibility of shortening the period of use of this powerful medication by developing new kinds of non-thrombogenic stents would, for example, make it possible to achieve significant reductions in subsequent bleeding during (dental) procedures.

  8. Simple balloon dilation for drug-eluting in-stent restenosis: An optical coherent tomography analysis

    Energy Technology Data Exchange (ETDEWEB)

    Arikawa, Ryo [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Yamaguchi, Hiroshi, E-mail: hyamaguchi@tsm.bbiq.jp [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Takaoka, Junichiro; Miyamura, Akihiro; Atsuchi, Nobuhiko; Ninomiya, Toshiko; Atsuchi, Yoshihiko [Division of Cardiology, Tenyoukai Central Hospital, Izumi-cho, Kagoshima City, Kagoshima (Japan); Ohishi, Mitsuru [Department of Cardiovascular Medicine and Hypertension, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima (Japan); Terashima, Mitsuyasu [Department of Cardiology, Toyohashi Heart Center, Toyohashi (Japan); Kaneda, Hideaki [Okinaka Memorial Institute for Medical Research, Tokyo (Japan)

    2015-01-15

    Background: Although drug-eluting stent (DES) has significantly reduced restenosis, the treatment of DES-in-stent restenosis (ISR) remains a challenge with high restenosis rate. Methods: We examined whether morphologic appearance of restenosis tissue by optical coherent tomography (OCT) had an impact on outcomes after balloon angioplasty for DES-ISR. The morphologic appearance of restenosis tissue was qualitatively assessed for tissue structures such as homogeneous, layered, and heterogeneous patterns. Results: Using OCT, 50 patients with DES-ISR were divided into 2 groups: 25 lesions with homogeneous or layered patterns (homo/layered group) and 25 lesions with heterogeneous patterns (hetero group). Acute gain was larger in the hetero group (1.33 ± 0.41 mm vs. 1.06 ± 0.32 mm in the homo/layered group, P = 0.03). On intravascular ultrasound analysis, post-procedural percent neointimal area was smaller in the hetero group (27.4 ± 9.2% vs. 34.0 ± 11.2% in the homo/layered group, P = 0.05). Angiographic follow-up was performed in 37 lesions (74%). Follow-up minimal lumen diameter was larger in the hetero group (1.75 ± 0.89 mm vs. 1.01 ± 0.81 mm in the homo/layered group, P = 0.04). Target lesion revascularization rates tended to be lower in the hetero group (20% vs. 43% in the homo/layered group, P = 0.12). Conclusions: Balloon angioplasty was more effective for DES-ISR with heterogeneous tissue appearance than DES-ISR with homogeneous/layered tissue appearance. OCT assessment of DES-ISR morphology may be a useful adjunct in determining clinical strategies. Simple balloon dilatation is a possible treatment strategy for DES-ISR lesions with a heterogeneous appearance on OCT images.

  9. Impact of stent strut design in metallic stents and biodegradable scaffolds.

    Science.gov (United States)

    Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip

    2014-12-20

    Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Zilver PTX Post-Market Surveillance Study of Paclitaxel-Eluting Stents for Treating Femoropopliteal Artery Disease in Japan: 12-Month Results.

    Science.gov (United States)

    Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Snyder, Scott A; Dake, Michael D

    2016-02-08

    This multicenter, prospective, post-market surveillance study in Japan evaluates the paclitaxel-coated Zilver PTX stent in real-world patients with complex lesions. The Zilver PTX stent is the first drug-eluting stent (DES) approved for the superficial femoral artery. Previously, results from a large randomized study and a complementary, large single-arm study supported the safety and effectiveness of the DES. There were no exclusion criteria, and consecutive patients with symptomatic peripheral artery disease (PAD) treated with the DES were enrolled in the study. Clinically driven target lesion revascularization (TLR) was defined as reintervention performed for ≥50% diameter stenosis after recurrent clinical symptoms of PAD. Clinical benefit was defined as freedom from persistent or worsening symptoms of ischemia. Patency was evaluated by duplex ultrasound where physicians considered this standard of care. In this study, 907 patients were enrolled at 95 institutions in Japan. There were numerous comorbidities including high incidences of diabetes (58.8%), chronic kidney disease (43.8%), and critical limb ischemia (21.5%). Lesions were also complex, with an average length of 14.7 cm, 41.6% total occlusions, and 18.6% in-stent restenosis. In total, 1,861 DES were placed in 1,075 lesions. Twelve-month follow-up was obtained for >95% of eligible patients. Freedom from TLR was 91.0%, and clinical benefit was 87.7% through 12 months. The 12-month primary patency rate was 86.4%. Despite more challenging lesions, results from the current study are similar to outcomes from the previous Zilver PTX studies, confirming the benefit of the Zilver PTX DES in a real-world patient population. (Zilver PTX Post-Market Study in Japan; NCT02254837). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Sirolimus effects on cancer incidence after kidney transplantation: a meta-analysis.

    Science.gov (United States)

    Yanik, Elizabeth L; Siddiqui, Kulsoom; Engels, Eric A

    2015-09-01

    Sirolimus, an immunosuppressant option for kidney transplant recipients, may reduce cancer risk by interrupting the mammalian target of rapamycin pathway. However, studies of sirolimus and cancer incidence in kidney recipients have not been definitive, and have had limited ability to examine specific cancer types. The literature was systematically reviewed to identify randomized controlled trials (RCTs) and observational studies of kidney recipients that compared sirolimus users to sirolimus nonusers. Meta-analytic methods were used to obtain pooled estimates of the association between sirolimus use and incidence of total cancer and specific cancer types. Estimates were stratified by study type (RCT vs. observational) and use of cyclosporine (an immunosuppressant that affects DNA repair). Twenty RCTs and two observational studies were eligible for meta-analysis, including 39,039 kidney recipients overall. Sirolimus use was associated with lower overall cancer incidence (incidence rate ratio [IRR] = 0.71, 95% CI = 0.56-0.90), driven by a reduction in incidence of nonmelanoma skin cancer (NMSC, IRR = 0.49, 95% CI = 0.32-0.76). The protective effect of sirolimus on NMSC risk was most notable in studies comparing sirolimus against cyclosporine (IRR = 0.19, 95% CI = 0.04-0.84). After excluding NMSCs, there was no overall association between sirolimus and incidence of other cancers (IRR = 1.06, 95% CI = 0.69-1.63). However, sirolimus use had associations with lower kidney cancer incidence (IRR = 0.40, 95% CI = 0.20-0.81), and higher prostate cancer incidence (IRR = 1.85, 95% CI = 1.17-2.91). Among kidney recipients, sirolimus users have lower NMSC risk, which may be partly due to removal of cyclosporine. Sirolimus may also reduce kidney cancer risk but did not appear protective for other cancers, and it may actually increase prostate cancer risk. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  12. Patients with previous definite stent thrombosis have a larger fraction of immature platelets and a reduced antiplatelet effect of aspirin

    DEFF Research Database (Denmark)

    Würtz, Morten; Grove, Erik; Wulff, Lise Nielsen

    turnover. Key Words: aspirin; immature platelets; platelet aggregation; platelet function tests; stent thrombosis Abbreviations: ARU, aspirin reaction units; AU, aggregation units; BMS, bare-metal stent(s); DES, drug-eluting stent(s); IPF, immature platelet fraction; MEA, multiple electrode aggregometry...

  13. Effect of sirolimus on urinary bladder cancer T24 cell line

    Directory of Open Access Journals (Sweden)

    Oliveira Paula A

    2009-01-01

    Full Text Available Abstract Background Sirolimus is recently reported to have antitumour effects on a large variety of cancers. The present study was performed to investigate sirolimus's ability to inhibit growth in T24 bladder cancer cells. Methods T24 bladder cancer cells were treated with various concentrations of sirolimus. MTT assay was used to evaluate the proliferation inhibitory effect on T24 cell line. The viability of T24 cell line was determined by Trypan blue exclusion analysis. Results Sirolimus inhibits the growth of bladder carcinoma cells and decreases their viability. Significant correlations were found between cell proliferation and sirolimus concentration (r = 0.830; p Conclusion Sirolimus has an anti-proliferation effect on the T24 bladder carcinoma cell line. The information from our results is useful for a better understanding sirolimus's anti-proliferative activity in the T24 bladder cancer cell line.

  14. Development and Validation of an HPLC Method for the Analysis of Sirolimus in Drug Products

    Directory of Open Access Journals (Sweden)

    Hadi Valizadeh

    2012-05-01

    Full Text Available Purpose: The aim of this study was to develop a simple, rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC method for quantification of sirolimus (SRL in pharmaceutical dosage forms. Methods: The chromatographic system employs isocratic elution using a Knauer- C18, 5 mm, 4.6 × 150 mm. Mobile phase consisting of acetonitril and ammonium acetate buffer set at flow rate 1.5 ml/min. The analyte was detected and quantified at 278nm using ultraviolet detector. The method was validated as per ICH guidelines. Results: The standard curve was found to have a linear relationship (r2 > 0.99 over the analytical range of 125–2000ng/ml. For all quality control (QC standards in intraday and interday assay, accuracy and precision range were -0.96 to 6.30 and 0.86 to 13.74 respectively, demonstrating the precision and accuracy over the analytical range. Samples were stable during preparation and analysis procedure. Conclusion: Therefore the rapid and sensitive developed method can be used for the routine analysis of sirolimus such as dissolution and stability assays of pre- and post-marketed dosage forms.

  15. Risk factors for in-stent restenosis of vertebral artery origin after stent implantation: a Meta-analysis

    Directory of Open Access Journals (Sweden)

    Fang-fang HAO

    2018-01-01

    Full Text Available Objective To systematically review the risk factors for in-stent restenosis (ISR of vertebral artery origin after sent implantation to provide theoretical foundation for clinical prevention and treatment. Methods Taking vertebral artery, vertebrobasilar insufficiency, stents, drug-eluting stents, self expandable metallic stents in English and Chinese as key words, retrospective clinical studies about risk factors for ISR of vertebral artery origin were searched by using PubMed, EMBASE/SCOPUS, Cochrane Library, China Biology Medicine (CBM, China National Knowledge Infrastructure (CNKI, Wanfang Data and VIP database from January 1, 1966 to March 30, 2017. Quality assessment and Meta-analysis were made by using Newcastle-Ottawa Scale (NOS and Stata 12.0 software. Results The research enrolled 3468 articles in all, from which 11 studies were chosen after excluding duplicates and those not meeting the inclusion criteria. A total number of 1352 patients were divided into ISR group (N = 440 and non-ISR group (N = 912. The ISR incidence rate of smokers was significantly higher than non-smokers (OR = 2.179, 95%CI: 1.373-3.458; P = 0.001. The differences of bare metal stents (BMS utilization rate (OR = 2.072, 95% CI: 1.560-2.753; P = 0.000 and drug-eluting stents (DES utilization rate (OR = 0.483, 95% CI: 0.363-0.641; P = 0.000 between ISR group and non-ISR group were statistically significant. Conclusions Smoking and using BMS are risk factors for ISR of vertebral artery origin, and using DES is protective factor. Due to limited study quality, more high-quality studies are needed to verify this conclusion. DOI: 10.3969/j.issn.1672-6731.2017.12.004

  16. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    International Nuclear Information System (INIS)

    Moscarella, Elisabetta; Varricchio, Attilio; Stabile, Eugenio; Franzone, Anna; Granata, Francesco; Rapacciuolo, Antonio; Galasso, Gennaro; Capozzolo, Claudia; Cirillo, Plinio

    2015-01-01

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  17. Bioabsorbable drug-eluting vascular scaffold for the treatment of coronary in-stent restenosis: A two center registry

    Energy Technology Data Exchange (ETDEWEB)

    Moscarella, Elisabetta [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Varricchio, Attilio [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Stabile, Eugenio, E-mail: geko50@hotmail.com [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Franzone, Anna [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Granata, Francesco [Division of Cardiology, Seconda Università degli studi di Napoli, AO Dei cColli, PO Monaldi (Italy); Rapacciuolo, Antonio; Galasso, Gennaro [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); Capozzolo, Claudia [Division of Cardiology, Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, Napoli (Italy); Cirillo, Plinio [Laboratory of Invasive Cardiology, Dipartimento di Cardiologia, Presidio Ospedaliero “Monaldi”, Azienda Ospedaliera “Dei Colli”, Napoli (Italy); and others

    2015-10-15

    Background/purpose: Coronary in-stent restenosis (ISR) is a clinical problem for which a satisfactory solution has not been found yet. Bioabsorbable drug eluting vascular scaffolds (BVSs) provide transient vessel scaffolding combined with prolonged drug delivery capability. The aim of this study was to investigate the safety of BVS for the treatment of coronary ISR. Methods/materials: Between January 2013 and June 2013, 27 patients (31 lesions), presenting with either stable or unstable angina due to coronary ISR, were enrolled in a single arm, prospective, open label registry. Primary end point was the occurrence of target vessel revascularization (TVR) at 12 months. Secondary end point was the composite of death, myocardial infarction and TVR at 12 months. Results: A diffuse ISR pattern was present in 70% of the lesions; mean lesion length was 34.6 ± 15. BVS was successfully implanted in all patients with no in hospital MACE. At twelve months of follow up, MACE rate was 18.5%. One patient died for non-cardiac reason, one patient died due to a possible stent thrombosis and TVR was necessary in 3 patients (11.1%). Conclusions: Our data suggest that BVS is safe and technically feasible for treatment of long and diffuse coronary ISR. These data could be considered hypothesis generator for a randomized clinical trial. - Highlights: • A safe therapeutic option for the treatment of diffuse ISR; • Technically feasible; • Associated to a low rate of restenosis recurrence at nine month.

  18. Current state of the absorbable metallic (magnesium) stent.

    Science.gov (United States)

    Waksman, Ron

    2009-12-15

    BIOTRONIK's absorbable metal stent technology is based ona magnesium alloy that offers superior stent mechanics and biocompatibility. The first generation (AMS-1) showed promising results regarding mechanical properties as well as feasibility and safety in several human applications (150 cases). The second generation (AMS-2.1) shows improved scaffolding and efficacy in animals due to a more slowly degrading magnesium alloy and an optimised stent design. The preclinical results of the drug-eluting AMS-3 are encouraging and the clinical investigational program will resume in 2010.

  19. In-hospital management and outcome of patients on warfarin undergoing coronary stent implantation: results of the multicenter, prospective WARfarin and coronary STENTing (WAR-STENT) registry.

    Science.gov (United States)

    Rubboli, Andrea; Sciahbasi, Alessandro; Briguori, Carlo; Saia, Francesco; Palmieri, Cataldo; Moroni, Luigi Andrea; Calabrò, Paolo; Leone, Antonio Maria; Franco, Nicoletta; Valgimigli, Marco; Varani, Elisabetta; Santi, Michela; Pasqualini, Paola; Capecchi, Alessandro; Piccalò, Giacomo; Margheri, Massimo; di Pasquale, Giuseppe; Galvani, Marcello; Bolognese, Leonardo; Gonzini, Lucio; Maggioni, Aldo Pietro

    2013-04-01

    The in-hospital management of patients on warfarin undergoing coronary stent implantation (PCI-S) is variable, and the in-hospital outcome incompletely defined. To determine the adherence to the current recommendations, and the incidence of adverse events, we carried out the prospective, multicenter, observational WARfarin and coronary STENTing (WAR-STENT) registry (ClinicalTrials.gov identifier NCT00722319). All consecutive patients on warfarin undergoing PCI-S at 37 Italian centers were enrolled and followed for 12 months. Outcome measures were: major adverse cardiovascular events (MACE), including cardiovascular death, non-fatal myocardial infarction, need for urgent revascularization, stroke, and venous thromboembolism, and major and minor bleeding. In this paper, we report the in-hospital findings. Out of the 411 patients enrolled, 92% were at non-low (ie, moderate or high) thromboembolic risk. The radial approach and bare-metal stents were used in 61% and 60% of cases, respectively. Drug-eluting stents were essentially reserved to patients with diabetes, which in turn, significantly predicted the implantation of drug-eluting stents (odds ratio [OR], 2.02; 95% confidence interval [CI], 1.29-3.17; P=.002). The in-hospital MACE and major bleeding rates were 2.7% and 2.1%, respectively. At discharge, triple therapy (TT) of warfarin, aspirin, and clopidogrel was prescribed to 76% of patients. Prescription of TT was significantly more frequent in the non-low thromboembolic risk group. Non-low thromboembolic risk, in turn, was a significant predictor of TT prescription (OR, 11.2; 95% CI, 4.83-26.3; P<.0001). In conclusion, real-world warfarin patients undergoing PCI-S are largely managed according to the current recommendations. As a consequence, the risk of in-hospital MACE and major bleedings appears limited and acceptable.

  20. [Fully absorbable drug eluting coronary stent: where do we stand in 2014?].

    Science.gov (United States)

    Kočka, Viktor; Toušek, Petr; Lisa, Libor; Buděšínský, Tomáš

    2014-04-01

    Coronary stent is routinely used in majority percutaneous coronary interventions for a long time. They have an important role, especially, in the first months after intervention. We can consider as a breakthrough point the development of stent which has ability to absorb in intervened artery after a few years. The review presents current techniques of fully absorbable coronary stents and also provides clinical trials and experiences available in 2014. The article continues with discussion between supporters and opponents of this new technique, but definitive conclusion can't be done yet. The authors conclude the review with their own opinion. There are many encouraging data in patients with good clinical outcome after implantation of absorbable stents in more than 10 years follow-up.

  1. Optical Coherence Tomography Findings in Patients With Stent Thrombosis.

    Science.gov (United States)

    Cuesta, Javier; Rivero, Fernando; Bastante, Teresa; García-Guimaraes, Marcos; Antuña, Paula; Alvarado, Teresa; Navarrete, Gonzalo; Benedicto, Amparo; Alfonso, Fernando

    2017-12-01

    Stent thrombosis (ST) is a rare but potentially serious complication. Optical coherence tomography (OCT) provides high-resolution images and additional information to angiography in the study of this event. Prospective study of patients with ST undergoing reintervention with OCT imaging. The study included a total of 40 consecutive patients with ST. Mean age was 69 ± 13 years and 83% were male. Early ST (≤ 30 days) was observed in 16 patients and late ST (> 30 days) in 24 patients. Stent thrombosis occurred in 17 bare-metal stents and 23 drug-eluting stents. In 34 patients (85%), adequate OCT images were obtained at the time of the ST. The predominant mechanism in early ST was stent malapposition (39%). In late ST, high frequencies of uncovered (46%) and malapposed struts (17%) were observed, especially in patients with drug-eluting stents. Furthermore, the presence of neoatherosclerosis was very high (67%) in patients with late ST. After intervention, improvements were observed in malapposition length and the amount of residual thrombus. OCT allows identification of the underlying mechanisms potentially involved in ST. This imaging modality is helpful in guiding reintervention in these patients, which improves the area and length of malapposition, as well as the maximal residual thrombus area. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. The (PrS/HGF-pDNA) multilayer films for gene-eluting stent coating: Gene-protecting, anticoagulation, antibacterial properties, and in vivo antirestenosis evaluation.

    Science.gov (United States)

    Chang, Hao; Ren, Ke-feng; Zhang, He; Wang, Jin-lei; Wang, Bai-liang; Ji, Jian

    2015-02-01

    Vascular gene-eluting stents (GES) is a promising strategy for treatment of cardiovascular disease. Very recently, we have proved that the (protamine sulfate/plasmid DNA encoding hepatocyte growth factor) (PrS/HGF-pDNA) multilayer can serve as a powerful tool for enhancing competitiveness of endothelial cell over smooth muscle cell, which opens perspectives for the regulation of intercellular competitiveness in the field of interventional therapy. However, before the gene multilayer films could be used in vascular stents for real clinical application, the preservation of gene bioactivity during the industrial sterilization and the hemocompatibility of film should be taken into account. Actually, both are long been ignored issues in the field of gene coating for GES. In this study, we demonstrate that the (PrS/HGF-pDNA) multilayer film exhibits the good gene-protecting abilities, which is confirmed by using the industrial sterilizations (gamma irradiation and ethylene oxide) and a routine storage condition (dry state at 4°C for 30 days). Furthermore, hemocompatible measurements (such as platelet adhesion and whole blood coagulation) and antibacterial assays (bacteria adhesion and growth inhibition) indicate the good anticoagulation and antibacterial properties of the (PrS/HGF-pDNA) multilayer film. The in vivo preliminary data of angiography and histological analysis suggest that the (PrS/HGF-pDNA) multilayer coated stent can reduce the in-stent restenosis. This work reveals that the (PrS/HGF-pDNA) multilayer film could be a promising candidate as coating for GES, which is of great potential in future clinic application. © 2014 Wiley Periodicals, Inc.

  3. Sirolimus use and incidence of venous thromboembolism in cardiac transplant recipients.

    Science.gov (United States)

    Thibodeau, Jennifer T; Mishkin, Joseph D; Patel, Parag C; Kaiser, Patricia A; Ayers, Colby R; Mammen, Pradeep P A; Markham, David W; Ring, W Steves; Peltz, Matthias; Drazner, Mark H

    2012-01-01

    Sirolimus is an immunosuppressive agent increasingly used in cardiac transplant recipients in the setting of allograft vasculopathy or worsening renal function. Recently, sirolimus has been associated with increased risk of venous thromboembolism (VTE) in lung transplant recipients. To investigate whether this association is also present in cardiac transplant recipients, we retrospectively reviewed the charts of 67 cardiac transplant recipients whose immunosuppressive regimen included sirolimus and 134 matched cardiac transplant recipients whose regimen did not include sirolimus. Rates of VTE were compared. Multivariable Cox proportional hazards models tested the association of sirolimus use with VTE. A higher incidence of VTE was seen in patients treated with vs. without sirolimus (8/67 [12%] vs. 9/134 [7%], log-rank statistic: 4.66, p=0.03). Lower body mass index (BMI) and total cholesterol levels were also associated with VTE (p<0.05). The association of sirolimus with VTE persisted when adjusting for BMI (hazard ratio [95% confidence interval]: 2.96 [1.13, 7.75], p=0.03) but not when adjusting for total cholesterol (p=0.08). These data suggest that sirolimus is associated with an increased risk of VTE in cardiac transplant recipients, a risk possibly mediated through comorbid conditions. Larger, more conclusive studies are needed. Until such studies are completed, a heightened level of awareness for VTE in cardiac transplant recipients treated with sirolimus appears warranted. © 2012 John Wiley & Sons A/S.

  4. Drug Interaction between Sirolimus and Ranolazine in a Kidney Transplant Patient

    Directory of Open Access Journals (Sweden)

    Joanna C. Masters

    2014-01-01

    Full Text Available Purpose. The case of a kidney transplant recipient who experienced a probable drug interaction between sirolimus and ranolazine is reported. Summary. The narrow therapeutic window of immunosuppressive therapy in transplant recipients requires close monitoring for potential drug-drug interactions. The patient, a 57-year-old Caucasian male kidney transplant recipient, was stable for years on sirolimus as his primary immunosuppressive agent and had a history of chronic angina, for which he was prescribed ranolazine. Upon addition and dose escalation of ranolazine, whole blood sirolimus levels more than tripled, rising to immeasurably high concentrations. After holding sirolimus on multiple occasions and reducing dosage more than 50%, blood levels returned to therapeutic range, while continuing ranolazine. Conclusion. Since ranolazine is a documented P-GP and CYP3A inhibitor, and sirolimus a known substrate for both pathways, it is proposed that ranolazine inhibition of P-GP and CYP3A4 contributed to the significant elevation in sirolimus exposure. No alternative causes for the rise in sirolimus exposure were found, and assessment with the Drug Interaction Probability Scale finds this interaction to be probable. Clinicians should be aware of the potential for this interaction to cause elevated sirolimus exposure and subsequent increase in clinical effect or toxicity, in this case overimmunosuppression.

  5. Drug-eluting stents with biodegradable polymer for the treatment of patients with diabetes mellitus: clinical outcome at 2 years in a large population of patients

    Directory of Open Access Journals (Sweden)

    Wiemer M

    2015-02-01

    Full Text Available Marcus Wiemer,1 Gian Battista Danzi,2 Nick West,3 Vassilios Voudris,4 René Koning,5 Stefan Hoffmann,6 Mario Lombardi,7 Josepa Mauri,8 Rade Babic,9 Fraser Witherow10On behalf of the NOBORI 2 Investigators 1Department of Cardiology, Heart and Diabetes Center North Rhine–Westphalia, Ruhr University Bochum, Bad Oeynhausen, Germany; 2Ospedale Maggiore Policlinico, Milan, Italy; 3Papworth Hospital, Cambridge, UK; 4Onassis Cardiac Surgery Center, Athens, Greece; 5Clinique Saint Hilaire, Rouen, France; 6Vivantes Netzwerk für Gesundheit GmbH, Berlin, Germany; 7Azienda Ospedaliera Villa Sofia, Palermo, Italy; 8Hospital Universitari Germans Trias i Pujol, Badalona, Spain; 9Institute for Cardiovascular Diseases Dedinje, Belgrade, Serbia; 10Dorset County Hospital, Dorchester, UK Objective: This study investigates the safety and efficacy of a third-generation drug-eluting stent (DES with biodegradable polymer in the complex patient population of diabetes mellitus (DM. Clinical trial registration: ISRCTN81649913. Background: Percutaneous coronary interventions in patients with DM are associated with a higher incidence of death, restenosis, and stent thrombosis as compared to non-diabetic patients. The use of a DES has been shown to improve outcomes in diabetic patients. Methods: Out of 3,067 patients, enrolled in 126 centers worldwide in the NOBORI 2 registry, 888 patients suffered from DM, 213 of them (14% being insulin-dependent DM (IDDM. Two years’ follow-up has been completed in this study. Results: At 1- and 2-year follow-up, 97% and 95% of the patients, respectively, were available. The reported target lesion failure (TLF rates at 1- and 2-year follow-up were 6.0% and 7.2% in the DM group, respectively, and 3.0% and 4.2% in the non-DM group, respectively (P<0.001 for both years. Inside the DM group, the TLF rates of 9.9% and 11.7% at the 1- and 2-year follow-ups, respectively, in patients with IDDM were significantly higher than the TLF rates of 4

  6. Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

    Science.gov (United States)

    Giacoppo, Daniele; Gargiulo, Giuseppe; Aruta, Patrizia; Capranzano, Piera; Tamburino, Corrado

    2015-01-01

    Study question What is the most safe and effective interventional treatment for coronary in-stent restenosis? Methods In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (either of bare metal stents or drug eluting stents; and either first or recurrent instances) were included. Trials including multiple treatments at the same time in the same group or comparing variants of the same intervention were excluded. Primary endpoints were target lesion revascularisation and late lumen loss, both at six to 12 months. The main analysis was complemented by network subanalyses, standard pairwise comparisons, and subgroup and sensitivity analyses. Study answer and limitations Twenty four trials (4880 patients), including seven interventional treatments, were identified. Compared with plain balloons, bare metal stents, brachytherapy, rotational atherectomy, and cutting balloons, drug coated balloons and drug eluting stents were associated with a reduced risk of target lesion revascularisation and major adverse cardiac events, and with reduced late lumen loss. Treatment ranking indicated that drug eluting stents had the highest probability (61.4%) of being the most effective for target lesion vascularisation; drug coated balloons were similarly indicated as the most effective treatment for late lumen loss (probability 70.3%). The comparative efficacy of drug coated balloons and drug eluting stents was similar for target lesion revascularisation (summary odds ratio 1.10, 95% credible interval 0.59 to 2.01) and late lumen loss reduction (mean difference in minimum lumen diameter 0.04 mm, 95% credible interval −0.20 to 0.10). Risks of death, myocardial infarction, and stent thrombosis were comparable across all treatments, but these analyses were limited by a

  7. Factors Associated with In-stent Restenosis in Patients Following Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Dedi Wihanda

    2015-07-01

    Full Text Available Aim: to determine factors associated with In-Stent Restenosis (ISR in patients following Percutaneous Coronary Intervention (PCI. Methods: a retrospective cross-sectional study was conducted using secondary information from medical records of post-PCI patients who underwent follow-up of angiography PCI between January 2009 and March 2014 at The Integrated Cardiovascular Service Unit, Cipto Mangunkusumo Hospital, Jakarta. Angiographic ISR was defined when the diameter of stenosis ≥50% at follow-up angiography including the diameter inside the stent and diameter with five-mm protrusion out of the proximal and distal ends of the stent. Results: there were 289 subjects including 133 subjects with and 156 subjects without ISR. The incidence of ISR in patients using of bare-metal stent (BMS and drug-eluting stent (DES were 61.3% and 40.7%, respectively. Factors associated with ISR are stent-type (OR=4.83, 95% CI 2.51-9.30, stent length (OR=3.71, 95% CI 1.99-6.90, bifurcation lesions (OR=2.43, 95% CI 1.16-5.10, smoking (OR=2.30, 95% CI 1.33-3.99, vascular diameter (OR=2.18, 95% CI 1.2-3.73, hypertension (OR=2.16, 95% CI 1.16-4.04 and diabetes mellitus (OR=2.14, 95% CI 1.23-3.70. Conclusion: stent type, stent length, bifurcation lesions, smoking, vascular diameter, hypertension and DM are factors associated with ISR in patients following PCI. Key words: bare-metal stent; drug-eluting stent; in-stent restenosis.

  8. The preparation of pitavastatin incorporated nanoparticle-eluting stent%载有匹伐他汀的纳米涂层支架的研究

    Institute of Scientific and Technical Information of China (English)

    赵钢; 朱伟; 陆志刚; 马士新; 和亚萍; 魏盟

    2012-01-01

    Objective To investigate the safety and effects of pitavastatin-loaded nanoparticles eluting stent in percutaneous coronary artery stent implantation in experimental porcine models. Methods The authors developed a novel drug eluting stent (DES) by using nanoparticles, which was made of biological absorbable FLGA material that could be coated on stent by using positive ion electroplating and coating technology. First, the human smooth muscle cells obtained from coronary artery and the human umbilical vein endothelial cells were cultured in vitro to observe the effects of statins on the cellular proliferation, which was compared with the effects of rapamycin and paclitaxel . The effects of statins-loaded nanoparticle eluting stent on Ultima proliferation and endothelial regeneration were then studied in vivo in experimental porcine by percutaneous coronary artery stent implantation. Results The FLAG nanoparticles labeled by FTTC were homogeneously coated on the stent by positive ion electroplating and coating technology. The results of in vitro experiment showed that approximately 40% of FITC was released from the nanoparticles within 24 hours, and all the rest was completely released after 30 days. FITC labeled nanoparticles were completely released from coating stent after 56 days. The results of in vitro experiment showed that statins could inhibit the proliferation of smooth muscle cells, but the pitavastatin exhibited the strongest inhibition effect compared with simvastatin, fluvastatin and atorvastatin (P 0.05). Moreover, the inflammation, fibrosis and endothelial cell regeneration seen in pitavastatin nanoparticle loaded DES were also markedly reduced (P < 0.01). Conclusion The pitavastatin loaded nanoparticle DES has been successfully developed. The use of this new pitavastatin loaded nanoparticle DES can significantly reduce the incidence of in-stent re-stenosis and thrombosis.(J Intervent Radiol, 2012, 21: 486-491)%目的

  9. Comparison of Acute Thrombogenicity for Metallic and Polymeric Bioabsorbable Scaffolds: Magmaris Versus Absorb in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Waksman, Ron; Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David M; Westman, Peter C; Joner, Michael; Zumstein, Philine; Kolodgie, Frank D; Virmani, Renu

    2017-08-01

    A comparison in acute thrombogenicity between the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold and the Absorb bioresorbable vascular scaffold has not been performed. This study assessed acute thrombogenicity of Magmaris compared with Absorb and the Orsiro hybrid drug-eluting stent in a porcine arteriovenous shunt model. An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to SYLGARD tubing containing the Magmaris, Absorb, and Orsiro scaffolds/stents and allowed to run in the shunt for a maximum of 1 hour. Twelve shunts (2 shunt runs per pig) were run comparing the 3 scaffolds in alternating order. Nested generalized linear mixed models were used to compare variables between scaffold groups while adjusting for variability between shunt runs. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that both Magmaris (3.0%) and Orsiro (4.6%) had less platelet coverage of the total scaffold compared with Absorb (21.8%). Scanning electron microscopy demonstrated significantly less thrombus deposition to Magmaris as a percentage of the total scaffold compared with Absorb (5.0% versus 16.1%, P =0.02). Magmaris had significantly less PM-1-positive neutrophil and CD14-positive monocyte adherence compared with both Orsiro and Absorb. Orsiro had significantly less monocyte deposition compared with Absorb. Despite a similar scaffold strut thickness, the Magmaris sirolimus-eluting bioabsorbable magnesium scaffold was significantly less thrombogenic compared with the Absorb bioresorbable vascular scaffold in an ex vivo porcine arteriovenous shunt model. Further studies are needed to determine whether the reduced thrombogenicity of Magmaris will result in reductions in major cardiovascular events. © 2017 American Heart Association, Inc.

  10. A comparative study of the effects of vitamin C, sirolimus, and paclitaxel on the growth of endothelial and smooth muscle cells for cardiovascular medical device applications

    Directory of Open Access Journals (Sweden)

    Kakade S

    2013-06-01

    Full Text Available Sandeep Kakade, Gopinath ManiBiomedical Engineering Program, The University of South Dakota, Sioux Falls, SD, USAAbstract: Antiproliferative drugs such as sirolimus (SIR and paclitaxel (PAT are currently released from stents and vascular grafts to inhibit the growth of smooth muscle cells (SMCs, thereby preventing neointimal hyperplasia. However, these drugs delay or impair the growth of endothelial cells (ECs on implant surfaces causing late thrombosis. Hence, there is a need to use alternative drugs in these implants to encourage the growth of ECs and to inhibit the growth of SMCs. Vitamin C (L-ascorbic acid [L-AA] is one such drug which has been shown to encourage EC growth and inhibit SMC growth when orally administered or added directly to the cell cultures. In this research, four sets of in vitro cell culture experiments were carried out to compare the effects of L-AA, SIR, and PAT on the growth of ECs and SMCs under similar conditions, and to compare the effects of different doses of L-AA to determine the optimal dose for promoting maximum EC growth and inhibiting SMC growth. The ECs and SMCs treated with different drugs were characterized for their viability and proliferation, and morphology using the quantitative resazurin assay (as well as qualitative fluorescence microscopy characterization and phase contrast microscopy, respectively, for up to 7 days. Also, the phenotype of ECs was characterized using immunofluorescence microscopy. Both SIR and PAT significantly inhibited the EC growth while L-AA significantly encouraged EC growth even more than that of the controls with no drugs. Also, L-AA significantly inhibited SMC growth although the inhibitory effect was inferior to that of SIR and PAT. The L-AA dosage study demonstrated that 100 µg and 300 µg of L-AA showed maximum EC growth after 7 days when compared to other dosages (1 µg, 500 µg, and 1000 µg of L-AA and controls investigated in this study. Also, the 100 µg and 300 µg

  11. Rationale and design of the East-West late lumen loss study: Comparison of late lumen loss between Eastern and Western drug-eluting stent study cohorts.

    Science.gov (United States)

    Harrison, Robert W; Radhakrishnan, Vaishnavi; Lam, Peter S; Allocco, Dominic J; Brar, Sandeep; Fahy, Martin; Fisher, Rebecca; Ikeno, Fumiaki; Généreux, Philippe; Kimura, Takeshi; Liu, Minglei; Lye, Weng Kit; Mintz, Gary S; Nagai, Hirofumi; Suzuki, Yuka; White, Roseann; Allen, John C; Krucoff, Mitchell W

    2016-12-01

    The contemporary evaluation of novel drug-eluting stents (DES) includes mechanistic observations that characterize postdeployment stent behavior. Quantification of late lumen loss due to neointimal hyperplasia 8-13 months after stent implantation, via quantitative coronary angiography (QCA), constitutes such an observation and is required by most regulatory authorities. Late lumen loss, as determined by QCA, has been validated as a surrogate for clinical endpoints such as target vessel revascularization. The mechanistic response to DES has not been directly compared across predominantly Asian or Western populations, whereas understanding their comparability across geographic populations could enhance global DES evaluation. The East-West late lumen loss study is designed to demonstrate whether the residual differences in late lumen loss, as assessed by QCA, is different between Eastern and Western DES recipients from studies with protocol angiography at 8-13 months of follow-up. Data from independent core laboratories that have characterized angiographic late lumen loss in DES clinical trials with protocol follow-up angiography will be compiled and dichotomized into Eastern and Western populations. A prospectively developed propensity score model incorporating clinical and anatomic variables affecting late lumen loss will be used to adjust comparisons of QCA measurements. Documentation of whether there are clinically meaningful differences in mechanistic response to DES implantation across genetically unique geographies could facilitate both the quality and efficiency of global device evaluation requiring invasive follow-up for novel stent designs. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Sirolimus-associated interstitial pneumonitis in a liver transplant recipient

    International Nuclear Information System (INIS)

    Claire Berrouet, Marie; Aristizabal, Julian Miguel; Restrepo, Juan Carlos; Correa, Gonzalo

    2005-01-01

    Sirolimus is an immunosuppressive drug that has been used during the past few years. Sirolimus is indicated in rescue therapies and to reduce the secondary toxic effects of calcineurin inhibitors. This drug has been associated with infrequent but severe pulmonary toxicity. Cases of interstitial pneumonitis, bronchiolitis obliterans with organizing pneumonia, and alveolar proteinosis have been described. We describe a case of pulmonary toxicity associated with the use of sirolimus in a 59-yr-old liver transplant recipient. We also review all reported cases of sirolimus-associated lung toxicity among liver transplantation recipients, with the intention of understanding the risk factors, the clinical picture and the outcomes of this complication. Five cases have been reported since January 2000, including the present case. Clinical presentation is similar, with fever, dyspnoea, fatigue, cough, and hemoptysis. Discontinuation of the drug led to resolution of clinical and radiographic findings. Sirolimus-induced pulmonary toxicity is a serious condition and should be considered in the differential diagnosis of liver recipients presenting with respiratory findings. Discontinuation of the drug is associated with resolution of the pulmonary compromise

  13. Tolerability of sirolimus: a decade of experience at a single cardiac transplant center.

    Science.gov (United States)

    Thibodeau, Jennifer T; Mishkin, Joseph D; Patel, Parag C; Kaiser, Patricia A; Ayers, Colby R; Mammen, Pradeep P A; Markham, David W; Ring, William Steves; Peltz, Matthias; Drazner, Mark H

    2013-01-01

    Sirolimus is used in cardiac transplant recipients to prevent rejection, progression of cardiac allograft vasculopathy, and renal dysfunction. However, sirolimus has many potential side effects and its tolerability when used outside of clinical trials is not well established. We describe a decade of experience with sirolimus in cardiac transplant recipients at our institution. We retrospectively reviewed records of all adult cardiac transplant recipients living between September 1999 and February 2010 (n = 329) and identified 67 patients (20%) who received sirolimus. The indications for sirolimus were cardiac allograft vasculopathy (67%), renal dysfunction (25%), rejection (4%), and intolerability of tacrolimus (3%). One-third of patients discontinued sirolimus at a median (25th, 75th percentiles) of 0.9 (0.2, 1.6) yr of duration. Over 70% of subjects experienced an adverse event attributed to sirolimus. Adverse events were associated with higher average sirolimus levels (9.1 ng/mL vs. 7.1 ng/mL, p = 0.004). We conclude that sirolimus is frequently used in cardiac transplant recipients (20%) and commonly causes side effects, often necessitating discontinuation. Higher average sirolimus levels were associated with adverse events, suggesting that tolerability may improve if levels are maintained within the lower end of the current therapeutic range; however, the improvement in tolerability would need to be balanced with the potential for decreased efficacy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Subconjunctival sirolimus in the treatment of diabetic macular edema.

    Science.gov (United States)

    Krishnadev, Nupura; Forooghian, Farzin; Cukras, Catherine; Wong, Wai; Saligan, Leorey; Chew, Emily Y; Nussenblatt, Robert; Ferris, Frederick; Meyerle, Catherine

    2011-11-01

    Diabetic macular edema (DME) is a leading cause of blindness in the developed world. Sirolimus has been shown to inhibit the production, signaling, and activity of many growth factors relevant to the development of diabetic retinopathy. This phase I/II study assesses the safety of multiple subconjunctival sirolimus injections for the treatment of DME, with some limited efficacy data. In this phase I/II prospective, open-label pilot study, five adult participants with diabetic macular edema involving the center of the fovea and best-corrected ETDRS visual acuity score of ≤74 letters (20/32 or worse) received 20 μl (440 μg) of subconjunctival sirolimus at baseline, month 2 and every 2 months thereafter, unless there was resolution of either retinal thickening on OCT or leakage on fluorescein angiography. Main outcome measures included best-corrected visual acuity and central retinal thickness on OCT at 6 months and 1 year, as well as safety outcomes. Repeated subconjunctival sirolimus injections were well-tolerated, with no significant drug-related adverse events. There was no consistent treatment effect related to sirolimus; one participant experienced a 2-line improvement in visual acuity and 2 log unit decrease in retinal thickness at 6 months and 1 year, two remained essentially stable, one had stable visual acuity but improvement of central retinal thickness of 1 and 3 log units at 6 months and 1 year respectively, and one had a 2-line worsening of visual acuity and a 1 log unit increase in retinal thickness at 6 months and 1 year. Results in the fellow eyes with diabetic macular edema, not treated with sirolimus, were similar. Subconjunctival sirolimus appears safe to use in patients with DME. Assessment of possible treatment benefit will require a randomized trial.

  15. Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction

    DEFF Research Database (Denmark)

    Räber, Lorenz; Kelbæk, Henning; Taniwaki, Masanori

    2014-01-01

    -treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0 ± 7.2 in BES- and 39.6 ± 25.2 in BMS-treated lesions (P segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued...

  16. Time course, predictors and clinical implications of stent thrombosis following primary angioplasty. Insights from the DESERT cooperation

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Dirksen, Maurits T; Spaulding, Christian

    2013-01-01

    on the timing of stent thrombosis (ST) with both DES and bare metal stents (BMS) and its prognostic significance in patients undergoing pPCI. The Drug-Eluting Stent in Primary Angioplasty (DESERT) cooperation is based on a pooled database including individual data of randomised trials that evaluate the long...

  17. Drug-Eluting Balloons in the Treatment of Coronary De Novo Lesions

    DEFF Research Database (Denmark)

    Richelsen, Rasmus Kapalu Broge; Overvad, Thure Filskov; Jensen, Svend Eggert

    2016-01-01

    Drug-eluting balloons (DEBs) have emerged as a new application in percutaneous coronary intervention. DEBs have proven successful in the treatment of in-stent restenosis, but their role in de novo lesions is less clear. This paper provides a review of the current studies where DEBs have been used...

  18. Impact of Anemia on Platelet Reactivity and Ischemic and Bleeding Risk: From the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents Study.

    Science.gov (United States)

    Giustino, Gennaro; Kirtane, Ajay J; Baber, Usman; Généreux, Philippe; Witzenbichler, Bernhard; Neumann, Franz-Josef; Weisz, Giora; Maehara, Akiko; Rinaldi, Michael J; Metzger, Christopher; Henry, Timothy D; Cox, David A; Duffy, Peter L; Mazzaferri, Ernest L; Brodie, Bruce R; Stuckey, Thomas D; Gurbel, Paul A; Dangas, George D; Francese, Dominic P; Ozan, Ozgu; Mehran, Roxana; Stone, Gregg W

    2016-06-15

    Anemic patients remain at increased risk of ischemic and bleeding events. Whether the effects of hemoglobin levels on thrombotic and bleeding risk are independent of platelet reactivity on clopidogrel, however, remains unknown. Patients from the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents study were categorized by the presence of anemia at baseline, defined according the World Health Organization criteria. Platelet reactivity was measured with VerifyNow assay; high platelet reactivity (HPR) on clopidogrel was defined as platelet reactive units value >208. Of 8,413 patients included in the study cohort, 1,816 (21.6%) had anemia. HPR was more prevalent in patients with anemia (58.3% vs 38.4%; p <0.001), an association that persisted after multivariate adjustment (adjusted odds ratio: 2.04; 95% confidence interval [CI]: 1.82 to 2.29; p <0.0001). Patients with anemia had higher 2-year rates of major adverse cardiac events (9.5% vs 5.6%; p <0.0001), major bleeding (11.8% vs 7.7%; p <0.0001), and all-cause mortality (4.0% vs 1.4%; p <0.0001); however, after adjustment for baseline clinical confounders, including HPR, anemia was no longer significantly associated with major adverse cardiac events but was still independently associated with all-cause mortality (adjusted HR 1.61, 95% CI 1.23 to 2.12; p <0.0001) and major bleeding (adjusted HR 1.42, 95% CI 1.20 to 1.68; p <0.0001). The effect of HPR on clinical outcomes was uniform according to anemia status, without evidence of interaction. In conclusion, anemia independently correlated with HPR. After percutaneous coronary intervention with drug-eluting stents, anemia at baseline was significantly associated with higher 2-year hemorrhagic and mortality risk; conversely, its association with ischemic risk was attenuated after multivariate adjustment, including HPR. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Outcomes of coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents for patients with multivessel coronary artery disease.

    Science.gov (United States)

    Javaid, Aamir; Steinberg, Daniel H; Buch, Ashesh N; Corso, Paul J; Boyce, Steven W; Pinto Slottow, Tina L; Roy, Probal K; Hill, Peter; Okabe, Teruo; Torguson, Rebecca; Smith, Kimberly A; Xue, Zhenyi; Gevorkian, Natalie; Suddath, William O; Kent, Kenneth M; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2007-09-11

    Advances in coronary artery bypass grafting (CABG) surgery and percutaneous coronary intervention (PCI) with drug-eluting stents have dramatically improved results of these procedures. The optimal treatment for patients with multivessel coronary artery disease is uncertain given the lack of prospective, randomized data reflecting current practice. This study represents a "real-world" evaluation of current technology in the treatment of multivessel coronary artery disease. A total of 1680 patients undergoing revascularization for multivessel coronary artery disease were identified. Of these, 1080 patients were treated for 2-vessel disease (196 CABG and 884 PCI) and 600 for 3-vessel disease (505 CABG and 95 PCI). One-year mortality, cerebrovascular events, Q-wave myocardial infarction, target vessel failure, and composite major adverse cardiovascular and cerebrovascular events were compared between the CABG and PCI cohorts. Outcomes were adjusted for baseline covariates and reported as hazard ratios. The unadjusted major adverse cardiovascular and cerebrovascular event rate was reduced with CABG for patients with 2-vessel disease (9.7% CABG versus 21.2% PCI; P<0.001) and 3-vessel disease (10.8% CABG versus 28.4% PCI; P<0.001). Adjusted outcomes showed increased major adverse cardiovascular and cerebrovascular event with PCI for patients with 2-vessel (hazard ratio 2.29; 95% CI 1.39 to 3.76; P=0.01) and 3-vessel disease (hazard ratio 2.90; 95% CI 1.76 to 4.78; P<0.001). Adjusted outcomes for the nondiabetic subpopulation demonstrated equivalent major adverse cardiovascular and cerebrovascular event with PCI for 2-vessel (hazard ratio 1.77; 95% CI 0.96 to 3.25; P=0.07) and 3-vessel disease (hazard ratio 1.70; 95% CI 0.77 to 3.61; P=0.19). Compared with PCI with drug-eluting stents, CABG resulted in improved major adverse cardiovascular and cerebrovascular event in patients with 2- and 3-vessel coronary artery disease, primarily in those with underlying diabetes

  20. Prognostic Value of Plasma Pentraxin-3 Levels in Patients with Stable Coronary Artery Disease after Drug-Eluting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Liu Haibo

    2014-01-01

    Full Text Available Pentraxin-3 (PTX3 is an inflammatory marker thought to be more specific to cardiovascular inflammation than C-reactive protein (CRP. Our aim was to assess the prognostic value of PTX3 in patients with stable coronary artery disease (CAD after drug eluting stent (DES implantation. Plasma PTX3 levels were measured before percutaneous coronary intervention (PCI and at 24 h post-PCI in 596 consecutive patients with stable CAD. Patients were followed up for a median of 3 years (range 1–5 for major adverse cardiovascular events (MACEs. We found that the post-PCI plasma PTX3 levels were significantly higher at 24 h after PCI than pre-PCI, patients with MACEs had higher post-PCI PTX3 levels compared with MACEs-free patients, patients with higher post-PCI PTX3 levels (median > 4.384 ng/mL had a higher risk for MACEs than those with PTX3 < 4.384 ng/mL, and post-PCI PTX3, cTnI, multiple stents, and age but not high-sensitivity CRP (hsCRP were independently associated with the prevalence of MACEs after DES implantation. The present study shows that post-PCI PTX3 may be a more reliable inflammatory predictor of long-term MACEs in patients with stable CAD undergoing DES implantation than CRP. Measurement of post-PCI PTX3 levels could provide a rationale for risk stratification of patients with stable CAD after DES implantation.

  1. Tracheal Self-Expandable Metallic Stents: A Comparative Study of Three Different Stents in a Rabbit Model.

    Science.gov (United States)

    Serrano, Carolina; Lostalé, Fernando; Rodríguez-Panadero, Francisco; Blas, Ignacio de; Laborda, Alicia; de Gregorio, Miguel Angel

    2016-03-01

    The objective of this study was to assess tracheal reactivity after the deployment of different self-expandable metal stents (SEMS). Forty female New Zealand rabbits were divided into four groups. Three groups received three different SEMS: steel (ST), nitinol (NiTi), or nitinol drug-eluting stent (DES); the fourth group was the control group (no stent). Stents were deployed percutaneously under fluoroscopic guidance. Animals were assessed by multi-slice, computed tomography (CT) scans, and tracheas were collected for anatomical pathology (AP) study. Data from CT and AP were statistically analyzed and correlated. The DES group had the longest stenosis (20.51±14.08mm vs. 5.84±12.43 and 6.57±6.54mm in NiTi and ST, respectively, day 30; Pstent. CT was more effective in detecting wall thickening (positive correlation of 68.9%; Pstent, while DES caused significant lesions that may be related to drug dosage. This type of DES stent is therefore not recommended for the treatment of tracheobronchial stenosis. Copyright © 2015 SEPAR. Published by Elsevier Espana. All rights reserved.

  2. Association Between Helicobacter Pylori Infection and Long-term Outcome in Patients with Drug-eluting Stent Implantation

    Science.gov (United States)

    Wang, Rui; Chen, Lei-Lei; Wang, De-Zhao; Chen, Bu-Xing

    2017-07-01

    To investigate the relationship between Helicobacter pylori (Hp) infection and the long-term outcome in acute coronary syndrome (ACS) patients with drug-eluting stent (DES) implantation and so as to explore the significance of Hp eradication therapy in preventing major adverse cardiac events (MACE) and upper gastrointestinal bleeding (UGIB). 539 ACS patients with DES implantation from January 1, 2010 to December 31, 2012 were analyzed. All the patients were divided into two groups according to the result of 13C urea breath test. 253 patients with Hp infection were put into group A (Hp+), and 286 cases without Hp infection were put into group B (Hp-). Demographic data was collected and all patients went through biochemical indicators and other routine blood examinations. We explored the correlations of Hp infection with MACE and UGIB after 3 to 5 years of follow-up using survival analysis. Survival analysis showed that Hp infection was a predictor of MACE and UGI. Sub-group analysis showed that patients with Hp eradication therapy had no relationship with MACE but had a lower rate of UGIB than those without Hp eradication therapy.

  3. Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.

    Science.gov (United States)

    Minami, Yoshiyasu; Wang, Zhao; Aguirre, Aaron D; Lee, Stephen; Uemura, Shiro; Soeda, Tsunenari; Vergallo, Rocco; Raffel, Owen C; Barlis, Peter; Itoh, Tomonori; Lee, Hang; Fujimoto, James; Jang, Ik-Kyung

    2016-01-01

    Methods for intravascular assessment of the side-branch (SB) orifice after stenting are not readily available. The aim of this study was to assess the utility of an en-face projection processing for optical coherence tomography (OCT) images for SB evaluation. Measurements of the SB orifice obtained using en-face OCT images were validated using a phantom model. Linear regression modeling was applied to estimated area measurements made on the en-face images. The SB orifice was then analyzed in 88 patients with bifurcation lesions treated with either Xience V (everolimus-eluting stent) or Resolute Integrity [zotarolimus-eluting stent (ZES)]. The SB orifice area (A) and the area obstructed by struts (B) were calculated, and the %open area was evaluated as (A-B)/A*100. Linear regression modeling demonstrated that the observed departures of the intercept and slope were not significantly different from 0 (-0.12 ± 0.22, P=0.59) and 1 (1.01 ± 0.06, R(2)=0.88, P=0.87), respectively. In cases without SB dilatation, the %open area was significantly larger in the everolimus-eluting stent group (n=25) than in the ZES group [n=32; 89.2% (83.7-91.3) vs. 84.3% (78.9-87.8), P=0.04]. A significant difference in %open area between cases with and those without SB dilatation was demonstrated in the ZES group [91.4% (86.1-94.0) vs. 84.3% (78.9-87.8), P=0.04]. The accuracy of SB orifice measurement on an en-face OCT image was validated using a phantom model. This novel approach enables quantitative evaluation of the differences in SB orifice area free from struts among different stent types and different treatment strategies in vivo.

  4. Absorb bioresorbable vascular scaffold versus everolimus-eluting metallic stent in ST-segment elevation myocardial infarction: 1-year results of a propensity score matching comparison: the BVS-EXAMINATION Study (bioresorbable vascular scaffold-a clinical evaluation of everolimus eluting coronary stents in the treatment of patients with ST-segment elevation myocardial infarction).

    Science.gov (United States)

    Brugaletta, Salvatore; Gori, Tommaso; Low, Adrian F; Tousek, Petr; Pinar, Eduardo; Gomez-Lara, Josep; Scalone, Giancarla; Schulz, Eberhard; Chan, Mark Y; Kocka, Viktor; Hurtado, Jose; Gomez-Hospital, Juan Antoni; Münzel, Thomas; Lee, Chi-Hang; Cequier, Angel; Valdés, Mariano; Widimsky, Petr; Serruys, Patrick W; Sabaté, Manel

    2015-01-01

    The purpose of this study was to compare the 1-year outcome between bioresorbable vascular scaffold (BVS) and everolimus-eluting metallic stent (EES) in ST-segment elevation myocardial infarction (STEMI) patients. The Absorb BVS (Abbott Vascular, Santa Clara, California) is a polymeric scaffold approved for treatment of stable coronary lesions. Limited and not randomized data are available on its use in ST-segment elevation myocardial infarction (STEMI) patients. This study included 290 consecutive STEMI patients treated by BVS, compared with either 290 STEMI patients treated with EES or 290 STEMI patients treated with bare-metal stents (BMS) from the EXAMINATION (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-segment Elevation Myocardial Infarction) trial, by applying propensity score matching. The primary endpoint was a device-oriented endpoint (DOCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization, at 1-year follow-up. Device thrombosis, according to the Academic Research Consortium criteria, was also evaluated. The cumulative incidence of DOCE did not differ between the BVS and EES or BMS groups either at 30 days (3.1% vs. 2.4%, hazard ratio [HR]: 1.31 [95% confidence interval (CI): 0.48 to 3.52], p = 0.593; vs. 2.8%, HR: 1.15 [95% CI: 0.44 to 2.30], p = 0.776, respectively) or at 1 year (4.1% vs. 4.1%, HR: 0.99 [95% CI: 0.23 to 4.32], p = 0.994; vs. 5.9%, HR: 0.50 [95% CI: 0.13 to 1.88], p = 0.306, respectively). Definite/probable BVS thrombosis rate was numerically higher either at 30 days (2.1% vs. 0.3%, p = 0.059; vs. 1.0%, p = 0.324, respectively) or at 1 year (2.4% vs. 1.4%, p = 0.948; vs. 1.7%, p = 0.825, respectively), as compared with EES or BMS. At 1-year follow-up, STEMI patients treated with BVS showed similar rates of DOCE compared with STEMI patients treated with EES or BMS, although rate of scaffolds thrombosis, mostly clustered in the early phase

  5. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy

    Energy Technology Data Exchange (ETDEWEB)

    Martí, David, E-mail: docalcala@hotmail.com [Department of Cardiology, Hospital Central de la Defensa, Madrid (Spain); López, Edurne; Álvarez, Salvador; Palazuelos, Jorge; Rada, Ignacio [Department of Cardiology, Hospital Central de la Defensa, Madrid (Spain); Alfonso, Fernando [Department of Cardiology, Hospital Universitario de La Princesa, Madrid (Spain)

    2016-12-15

    The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. - Highlights: • Optical coherence tomography (OCT) has the unique ability to detect lipid accumulation within the stent margins (i.e. neoatherosclerosis). • Lipid-rich tissues produce light absorption and therefore they typically attenuate backward signals. • Occlusive neoatherosclerosis may appear even in optimally implanted drug eluting stents. • OCT identification of restenosis mechanisms may have implications not only in the interventional strategy, but also in the long-term medical treatment.

  6. Neoatherosclerosis causing occlusive in-stent restenosis: Impact of intracoronary imaging in the intensity of lipid-lowering therapy

    International Nuclear Information System (INIS)

    Martí, David; López, Edurne; Álvarez, Salvador; Palazuelos, Jorge; Rada, Ignacio; Alfonso, Fernando

    2016-01-01

    The unique physical properties of optical coherence tomography (OCT) make it a useful technique in the study of restenosis mechanisms. In fact, OCT is able to differentiate between neointimal proliferation and neoatherosclerosis within the stent. We report a rare case of occlusive neoatherosclerosis presenting beyond one year after a successful drug-eluting stent implantation. The impact of OCT findings in the clinical decision making process is emphasized. - Highlights: • Optical coherence tomography (OCT) has the unique ability to detect lipid accumulation within the stent margins (i.e. neoatherosclerosis). • Lipid-rich tissues produce light absorption and therefore they typically attenuate backward signals. • Occlusive neoatherosclerosis may appear even in optimally implanted drug eluting stents. • OCT identification of restenosis mechanisms may have implications not only in the interventional strategy, but also in the long-term medical treatment.

  7. The SYNERGY biodegradable polymer everolimus eluting coronary stent: Porcine vascular compatibility and polymer safety study.

    Science.gov (United States)

    Wilson, Gregory J; Marks, Angela; Berg, Kimberly J; Eppihimer, Michael; Sushkova, Natalia; Hawley, Steve P; Robertson, Kimberly A; Knapp, David; Pennington, Douglas E; Chen, Yen-Lane; Foss, Aaron; Huibregtse, Barbara; Dawkins, Keith D

    2015-11-15

    SYNERGY is a novel platinum chromium alloy stent that delivers abluminal everolimus from an ultrathin poly-lactide-co-glycide (PLGA) biodegradable polymer. This study evaluated the in vivo degradation of the polymer coating, everolimus release time course, and vascular compatibility of the SYNERGY stent. SYNERGY stents were implanted in arteries of domestic swine. Devices were explanted at predetermined time points (up to 120 days) and the extent of PLGA coating or everolimus remaining on the stents was quantified. Everolimus levels in the arterial tissue were also evaluated. A pathological analysis on coronary arteries of single and overlapping stents was performed at time points between 5 and 270 days. PLGA bioabsorption began immediately after implantation, and drug release was essentially complete by 90 days; PLGA absorption was substantially complete by 120 days (>90% of polymer was absorbed) leaving a bare metal SYNERGY stent. Vascular response was similar among SYNERGY and control stents (bare metal, polymer-only, and 3× polymer-only). Mild increases in para-strut fibrin were seen for SYNERGY at an early time point with no significant differences in all other morphological and morphometric parameters through 270 days or endothelial function (eNOS immunostaining) at 90 or 180 days. Inflammation was predominantly minimal to mild for all device types. In a swine model, everolimus was released by 90 days and PLGA bioabsorption was complete shortly thereafter. The SYNERGY stent and its biodegradable polymer, even at a 3× safety margin, demonstrated vascular compatibility similar to bare metal stent controls. © 2015 Wiley Periodicals, Inc.

  8. Development and Physicochemical Characterization of Sirolimus Solid Dispersions Prepared by Solvent Evaporation Method

    Directory of Open Access Journals (Sweden)

    Shahram Emami

    2014-12-01

    Full Text Available Purpose: The aim of the present investigation was preparation and characterization of sirolimus solid dispersions by solvent evaporation technique to improve its dissolution properties. Methods: Polyvinylpyrrolidone (PVP, Poloxamer 188 and Cremophore RH40 were used to prepare the solid dispersions of sirolimus. In vitro dissolution study using USP type I apparatus, were performed in distilled water (containing SLS 0.4% for pure sirolimus, physical mixtures, Rapamune and prepared solid dispersions. The characterization of solid dispersions was performed using Fourier Transform Infrared (FTIR Spectroscopy and Differential Scanning Calorimetry (DSC. Results: More than 75% of sirolimus was released within 30 minutes from all prepared solid dispersions. The dissolution rate of all prepared solid dispersion powders were more than physical mixtures. The absence of sirolimus peak in the DSC spectrum of solid dispersions indicated the conversion of crystalline form of sirolimus into amorphous form. The results from FT-IR spectroscopy showed that there was no significant change in the FT-IR spectrum of solid dispersions indicating absence of well-defined interaction between drug and carriers. Conclusion: It was concluded that solid dispersion method, using PVP, Poloxamer 188 and Cremophore RH40 can improve dissolution rate of sirolimus.

  9. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  10. Enhanced bioavailability of sirolimus via preparation of solid dispersion nanoparticles using a supercritical antisolvent process

    Directory of Open Access Journals (Sweden)

    Kim MS

    2011-11-01

    Full Text Available Min-Soo Kim1, Jeong-Soo Kim1, Hee Jun Park1, Won Kyung Cho1,3, Kwang-Ho Cha1,3, Sung-Joo Hwang2,31College of Pharmacy, Chungnam National University, Daejeon, Republic of Korea, 2College of Pharmacy, 3Yonsei Institute of Pharmaceutical Sciences, Yonsei University, Incheon, Republic of KoreaBackground: The aim of this study was to improve the physicochemical properties and bioavailability of poorly water-soluble sirolimus via preparation of a solid dispersion of nanoparticles using a supercritical antisolvent (SAS process.Methods: First, excipients for enhancing the stability and solubility of sirolimus were screened. Second, using the SAS process, solid dispersions of sirolimus-polyvinylpyrrolidone (PVP K30 nanoparticles were prepared with or without surfactants such as sodium lauryl sulfate (SLS, tocopheryl propylene glycol succinate, Sucroester 15, Gelucire 50/13, and Myrj 52. A mean particle size of approximately 250 nm was obtained for PVP K30-sirolimus nanoparticles. Solid state characterization, kinetic solubility, powder dissolution, stability, and pharmacokinetics were analyzed in rats.Results: X-ray diffraction, differential scanning calorimetry, and high-pressure liquid chromatography indicated that sirolimus existed in an anhydrous amorphous form within a solid dispersion of nanoparticles and that no degradation occurred after SAS processing. The improved supersaturation and dissolution of sirolimus as a solid dispersion of nanoparticles appeared to be well correlated with enhanced bioavailability of oral sirolimus in rats. With oral administration of a solid dispersion of PVP K30-SLS-sirolimus nanoparticles, the peak concentration and AUC0→12h of sirolimus were increased by approximately 18.3-fold and 15.2-fold, respectively.Conclusion: The results of this study suggest that preparation of PVP K30-sirolimus-surfactant nanoparticles using the SAS process may be a promising approach for improving the bioavailability of sirolimus

  11. Long term outcomes of new generation drug eluting stents versus coronary artery bypass grafting for multivessel and/or left main coronary artery disease. A Bayesian network meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Mina, George S; Watti, Hussam; Soliman, Demiana; Shewale, Anand; Atkins, Jessica; Reddy, Pratap; Dominic, Paari

    2018-01-05

    Most data guiding revascularization of multivessel disease (MVD) and/or left main disease (LMD) favor coronary artery bypass grafting (CABG) over percutaneous coronary intervention (PCI). However, those data are based on trials comparing CABG to bare metal stents (BMS) or old generation drug eluting stents (OG-DES). Hence, it is essential to outcomes of CABG to those of new generation drug eluting stents (NG-DES). We searched PUBMED and Cochrane database for trials evaluating revascularization of MVD and/or LMD with CABG and/or PCI. A Bayesian network meta-analysis was performed to calculate odds ratios (OR) and 95% credible intervals (CrI). Primary outcome was major adverse cardiovascular events (MACE) at 3-5 years. Secondary outcomes were mortality, cerebrovascular accidents (CVA), myocardial infarction (MI) and repeat revascularization. We included 10 trials with a total of 9287 patients. CABG was associated with lower MACE when compared to BMS or OG-DES. However, MACE was not significantly different between CABG and NG-DES (OR 0.79, CrI 0.45-1.40). Moreover, there were no significant differences between CABG and NG-DES in mortality (OR 0.78, CrI 0.45-1.37), CVA (OR 0.93 CrI 0.35-2.2) or MI (OR 0.6, CrI 0.17-2.0). On the other hand, CABG was associated with lower repeat revascularization (OR 0.55, CrI 0.36-0.84). Our study suggests that NG-DES is an acceptable alternative to CABG in patients with MVD and/or LMD. However, repeat revascularization remains to be lower with CABG than with PCI. Copyright © 2018. Published by Elsevier Inc.

  12. In vivo evaluation of axial integrity of coronary stents using intravascular ultrasound: Insights on longitudinal stent deformation.

    Science.gov (United States)

    Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron

    2014-09-01

    To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.

  13. Severe Hypertriglyceridemia Induced by Sirolimus Treated With Medical Management Without Plasmapheresis: A Case Report.

    Science.gov (United States)

    Kido, Kazuhiko; Evans, Rickey A; Gopinath, Anil; Flynn, Jeremy D

    2018-02-01

    Hypertriglyceridemia and hyperlipidemia are the most remarkable metabolic complications seen with long-term sirolimus therapy. We report the case of a 36-year-old woman status post bilateral lung transplantation on a maintenance immunosuppression regimen of sirolimus, tacrolimus, and prednisone who presented with status migrainosus, chest pain, abdominal discomfort, and triglyceride levels greater than 4425 mg/dL. In previously reported cases of severe hypertriglyceridemia that developed on maintenance sirolimus therapy, plasmapheresis has been utilized as an early strategy to rapidly lower triglycerides in order to minimize the risk of acute complications such as pancreatitis, but our case was managed medically without plasmapheresis. The most recent triglyceride was down to 520 mg/dL 2 months after discontinuation of sirolimus. We estimate the probability of this reaction to sirolimus as probable based on a score of 5 points on the Naranjo scale. This is the first case report to our knowledge that highlights the sole use of oral lipid-lowering drug agents to treat severe hypertriglyceridemia secondary to sirolimus without the use of plasmapheresis. Sirolimus-induced severe hypertriglyceridemia can be managed with oral lipid-lowering agents without plasmapheresis. Clinician needs to be aware of the importance of baseline and regular triglyceride monitoring in patients on sirolimus.

  14. [Value of the optical coherence tomography in the treatment guided of the stent failure. Case report].

    Science.gov (United States)

    Macías, Enrico; Tellez, Alejandro; Ochoa, Jorge; Ortíz, José E

    2014-01-01

    Since the advent of bare metal and drug-eluting stents, the surgical revascularization have declined considerably, however the thrombosis and in-stent restenosis are important complications of these devices. There are several factors that predispose to thrombosis and in-stent restenosis. Conventional angiography has serious limitations to determine the causes of stent failure. Optical coherence tomography is a very sensitive technique to determine the cause of thrombosis and in-stent restenosis. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  15. Topical sirolimus for the treatment of angiofibromas in tuberous sclerosis

    Directory of Open Access Journals (Sweden)

    Salih Levent Cinar

    2017-01-01

    Full Text Available Background: The skin is one of the most affected organs in tuberous sclerosis complex and angiofibromas are seen in almost 80% of such patients. These benign tumors impose a great psycho-social burden on patients. Objective: The aim of the study was to evaluate the effectiveness and tolerability of topical sirolimus for facial angiofibromas in patients with tuberous sclerosis complex. Methods: This was a prospective, single-blinded, cross-over study which involved twelve patients. We investigated the effect and safety of topical 0.1% sirolimus, which was obtained by crushing sirolimus tablets and mixing it with petrolatum. The patients were asked to apply the cream to one side of their face, and vaseline to the other side. The effect of topical sirolimus was evaluated using the “facial angiofibroma severity index.” Results: There was a significant improvement in the redness and extension of the tumors on the sides to which the active ingredient was applied. Some side effects such as itching and irritation occurred in three patients, which were treated with topical hydrocortisone cream. Conclusion: Topical sirolimus appears to be a promising, fairly well tolerated treatment for facial angiofibromas in patients with tuberous sclerosis complex. Although its efficacy diminishes with time, repetitive usage is effective.

  16. Kinetic study of ultrasonic antisolvent crystallization of sirolimus

    Energy Technology Data Exchange (ETDEWEB)

    Gandhi, P.J. [Chemical Engineering Department, S. V. National Institute of Technology, Surat 395007, Gujarat (India); Concept Medical Research Pvt. Ltd., Ground Floor, Narayan Darshan, Nr. Rupam Cinema, Salabatpura, Surat 395003, Gujarat (India); Murthy, Z.V.P.

    2010-03-15

    Sirolimus, generally used in organ transplantation, is derived from bacterium Streptomyces hygroscopicus. Mass transfer controlled ultrasonic antisolvent method was used for determining the precipitation kinetics of sirolimus. The effect of temperature was determined on the particles size, percentage recovery, critical radius of nucleus, mass transfer coefficient, etc. for sirolimus dissolved in methanol and antisolvent water using ultrasonic treatment. The study was done using classical nucleation theory, which can also be applied to precipitation processes. Experiments were carried out at various temperatures; viz: 45, 50, 60 and 70 C and the percentage recoveries of sirolimus were found to be 90.74, 91.5, 92.64 and 93.61%, respectively, for initial amount of 8 mg dissolved in 1 mL of solvent and further introduced into 12 mL of HPLC water. The final average diameters of crystals observed for the temperatures were 1371, 1287, 1063 and 863 nm, respectively. The systems were found to be mass transfer controlling and that the mass diffusivities were found to be about 3.97 x 10{sup -9}, 4.00 x 10{sup -9}, 3.01 x 10{sup -9} and 1.92 x 10{sup -9} m{sup 2}/s, respectively. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Optimized formulation of solid self-microemulsifying sirolimus delivery systems

    Directory of Open Access Journals (Sweden)

    Cho W

    2013-04-01

    Full Text Available Wonkyung Cho,1,2 Min-Soo Kim,3 Jeong-Soo Kim,2 Junsung Park,1,2 Hee Jun Park,1,2 Kwang-Ho Cha,1,2 Jeong-Sook Park,2 Sung-Joo Hwang1,4 1Yonsei Institute of Pharmaceutical Sciences, Yonsei University, Incheon, Republic of Korea; 2College of Pharmacy, Chungnam National University, Daejeon, Republic of Korea; 3Department of Pharmaceutical Engineering, Inje University, Gimhae, Republic of Korea; 4College of Pharmacy, Yonsei University, Incheon, Republic of Korea Background: The aim of this study was to develop an optimized solid self-microemulsifying drug delivery system (SMEDDS formulation for sirolimus to enhance its solubility, stability, and bioavailability. Methods: Excipients used for enhancing the solubility and stability of sirolimus were screened. A phase-separation test, visual observation for emulsifying efficiency, and droplet size analysis were performed. Ternary phase diagrams were constructed to optimize the liquid SMEDDS formulation. The selected liquid SMEDDS formulations were prepared into solid form. The dissolution profiles and pharmacokinetic profiles in rats were analyzed. Results: In the results of the oil and cosolvent screening studies, Capryol™ Propylene glycol monocaprylate (PGMC and glycofurol exhibited the highest solubility of all oils and cosolvents, respectively. In the surfactant screening test, D-α-tocopheryl polyethylene glycol 1000 succinate (vitamin E TPGS was determined to be the most effective stabilizer of sirolimus in pH 1.2 simulated gastric fluids. The optimal formulation determined by the construction of ternary phase diagrams was the T32 (Capryol™ PGMC:glycofurol:vitamin E TPGS = 30:30:40 weight ratio formulation with a mean droplet size of 108.2 ± 11.4 nm. The solid SMEDDS formulations were prepared with Sucroester 15 and mannitol. The droplet size of the reconstituted solid SMEDDS showed no significant difference compared with the liquid SMEDDS. In the dissolution study, the release amounts of

  18. Shrinking the Supply Chain for Implantable Coronary Stent Devices.

    Science.gov (United States)

    Moore, Sean S; O'Sullivan, Kevin J; Verdecchia, Francesco

    2016-02-01

    Stenting treatments for the management of disease in the heart, arterial and venous systems, biliary ducts, urethras, ureters, oesophageal tract and prostate have made enormous technical advances since their introduction into clinical use. The progression from metallic to polymer based bio-absorbable stents, coupled with the advances in additive manufacturing techniques, present a unique opportunity to completely re-envision the design, manufacture, and supply chain of stents. This paper looks at current stenting trends and proposes a future where the stent supply chain is condensed from ~150 days to ~20 min. The Cardiologist therefore has the opportunity to become a designer, manufacturer and user with patients receiving custom stents specific to their unique pathology that will be generated, delivered and deployed in the Cath-lab. The paper will outline this potentially revolutionary development and consider the technical challenges that will need to be overcome in order to achieve these ambitious goals. A high level overview of the generating eluting stents in situ program-GENESIS-is outlined including some early experimental work.

  19. Novel biliary self-expanding metal stents: indications and applications.

    Science.gov (United States)

    Blero, Daniel; Huberty, Vincent; Devière, Jacques

    2015-03-01

    Endoscopic insertion of a self-expanding metal stent (SEMS) through a malignant common bile duct stricture is the first line of palliation for malignant jaundice. Patency of these stents remains a major concern. SEMS dysfunction can result from tumor ingrowth, overgrowth and/or clogging. Initial SEMS modifications involved covering the central part of the stent in order to reduce ingrowth and ultimately increase patency. Fully covered stents became available shortly after reports of their use in human patients. The potential removability and radial strength of SEMS have led to evaluation of their use in new indications including benign biliary strictures, post sphincterotomy bleeding and perforation. Other aspects of development include the addition of features such as anti-reflux valves, drug elution and spontaneous biodegradability. These aspects and their clinical implications are reviewed and discussed.

  20. Rapid Globalization of Medical Device Clinical Development Programs in Japan - The Case of Drug-Eluting Stents.

    Science.gov (United States)

    Murakami, Madoka; Suzuki, Yuka; Tominaga, Toshiyoshi

    2018-02-23

    Delays in the introduction to the Japanese market of drug-eluting stents (DES) developed overseas (i.e., "device lag") decreased sharply between 2004 and 2012. The reduction accompanied a shift in clinical development from a succession pattern (initial product development and approval overseas followed by eventual entrance into the Japanese market) to parallel development (employing multiregional clinical trials (MRCTs)). Although resource-intensive in the short-term, MRCTs are proving to be an effective tool in simultaneous global product development. Creative study designs and the absence of significant ethnic differences in Japanese subjects regarding DES safety and efficacy and the pharmacokinetic behavior of their coating drugs propel this process. More general factors such as medical need and industry incentivization also encourage this shift. Physicians' preference for DES over other percutaneous coronary interventions, the expanding global DES market, and streamlined development and approval prospects each motivate industry to continue investing in DES product development. The efforts of various stakeholders were also integral to overcoming practical obstacles, and contributions by 'Harmonization by Doing' and a premarket collaboration initiative between the USA and Japan were particularly effective. Today, USA/Japan regulatory cooperation is routine, and Japan is now integrated into global medical device development. MRCTs including Japanese subjects, sites, and investigators are now commonplace.

  1. Long-term forecasting and comparison of mortality in the Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial: prospective validation of the SYNTAX Score II.

    Science.gov (United States)

    Campos, Carlos M; van Klaveren, David; Farooq, Vasim; Simonton, Charles A; Kappetein, Arie-Pieter; Sabik, Joseph F; Steyerberg, Ewout W; Stone, Gregg W; Serruys, Patrick W

    2015-05-21

    To prospectively validate the SYNTAX Score II and forecast the outcomes of the randomized Evaluation of the Xience Everolimus-Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) Trial. Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization is a prospective, randomized multicenter trial designed to establish the efficacy and safety of percutaneous coronary intervention (PCI) with the everolimus-eluting stent compared with coronary artery bypass graft (CABG) surgery in subjects with unprotected left-main coronary artery (ULMCA) disease and low-intermediate anatomical SYNTAX scores (EXCEL, the SYNTAX Score II was prospectively applied to predict 4-year mortality in the CABG and PCI arms. The 95% prediction intervals (PIs) for mortality were computed using simulation with bootstrap resampling (10 000 times). For the entire study cohort, the 4-year predicted mortalities were 8.5 and 10.5% in the PCI and CABG arms, respectively [odds ratios (OR) 0.79; 95% PI 0.43-1.50). In subjects with low (≤22) anatomical SYNTAX scores, the predicted OR was 0.69 (95% PI 0.34-1.45); in intermediate anatomical SYNTAX scores (23-32), the predicted OR was 0.93 (95% PI 0.53-1.62). Based on 4-year mortality predictions in EXCEL, clinical characteristics shifted long-term mortality predictions either in favour of PCI (older age, male gender and COPD) or CABG (younger age, lower creatinine clearance, female gender, reduced left ventricular ejection fraction). The SYNTAX Score II indicates at least an equipoise for long-term mortality between CABG and PCI in subjects with ULMCA disease up to an intermediate anatomical complexity. Both anatomical and clinical characteristics had a clear impact on long-term mortality predictions and decision making between CABG and PCI. Published on behalf of the European Society of Cardiology. All rights reserved. © The

  2. Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents (BIONYX) : Rationale and design of the randomized TWENTE IV multicenter trial

    NARCIS (Netherlands)

    van der Heijden, Liefke C.; Kok, Marlies M.; Zocca, Paolo; Jessurun, Gillian A.J.; Schotborgh, Carl E.; Roguin, Ariel; Benit, Edouard; Aminian, Adel; Danse, Peter W.; Löwik, Marije M.; Linssen, Gerard C.M.; van der Palen, Job; Doggen, Carine J.M.; von Birgelen, Clemens

    2018-01-01

    Aim: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. Methods and results: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an

  3. Two-year follow-up of percutaneous coronary intervention using EucaTax or Cypher

    International Nuclear Information System (INIS)

    Shuvalova, Yulia A.; Shirokov, Roman O.; Kaminnaya, Violetta I.; Samko, Anatoliy N.; Kaminnyi, Alexander I.

    2013-01-01

    Background: The EucaTax stent (EUPES) is a coronary stent with biodegradable polymer and camouflage coating that has been developed to promote the complete elution of drugs and decrease the risk of late complications. The aim of this study was to evaluate the efficacy and safety of the double-coated EUPES in patients with stable angina versus sirolimus-eluting stent CYPHER (SES) with permanent polymer coating. Methods and Materials: The study included consecutive patient with at least 70% de novo coronary lesions in one or two native coronary arteries and who had undergone the coronary stenting using either EUPES or SES. We evaluated the 2-year major adverse cardiac events (MACE) rates, including total death (cardiac, non-cardiac), myocardial infarction (MI), target lesion revascularisation (TLR) and stent thrombosis. Results: Between 2006 and 2009 this observational, prospective, single centre study included 602 patients (282 with EUPES and 320 with SES). At 2 years, the rates of TLR (16.3% versus 6.25%; p = 0.0001) and MACE (18.4% versus 7.8%; p = 0.001) were significantly higher in the EUPES than in the SES group. The rate of TLR was significantly higher in the EUPES group compared with SES group in stenting of artery with a diameter less than 3 mm, using stent length more than 18 mm, as well as when the residual stenosis was more than 12%. Conclusions: We found that EUPES was inferior to SES during the 2-year follow-up with respect to rates of MACE and TLR that were significantly higher in the EUPES than in the SES group

  4. Two-year follow-up of percutaneous coronary intervention using EucaTax or Cypher

    Energy Technology Data Exchange (ETDEWEB)

    Shuvalova, Yulia A., E-mail: shuvalovaj@mail.ru [Russian Cardiology Research and Production Complex, Department of Atherosclerosis Problems (Russian Federation); Shirokov, Roman O. [Russian Cardiology Research and Production Complex, Laboratory of Radio Vascular Therapy (Russian Federation); Kaminnaya, Violetta I. [Russian Cardiology Research and Production Complex, Department of Atherosclerosis Problems (Russian Federation); Samko, Anatoliy N. [Russian Cardiology Research and Production Complex, Laboratory of Radio Vascular Therapy (Russian Federation); Kaminnyi, Alexander I. [Russian Cardiology Research and Production Complex, Department of Atherosclerosis Problems (Russian Federation)

    2013-09-15

    Background: The EucaTax stent (EUPES) is a coronary stent with biodegradable polymer and camouflage coating that has been developed to promote the complete elution of drugs and decrease the risk of late complications. The aim of this study was to evaluate the efficacy and safety of the double-coated EUPES in patients with stable angina versus sirolimus-eluting stent CYPHER (SES) with permanent polymer coating. Methods and Materials: The study included consecutive patient with at least 70% de novo coronary lesions in one or two native coronary arteries and who had undergone the coronary stenting using either EUPES or SES. We evaluated the 2-year major adverse cardiac events (MACE) rates, including total death (cardiac, non-cardiac), myocardial infarction (MI), target lesion revascularisation (TLR) and stent thrombosis. Results: Between 2006 and 2009 this observational, prospective, single centre study included 602 patients (282 with EUPES and 320 with SES). At 2 years, the rates of TLR (16.3% versus 6.25%; p = 0.0001) and MACE (18.4% versus 7.8%; p = 0.001) were significantly higher in the EUPES than in the SES group. The rate of TLR was significantly higher in the EUPES group compared with SES group in stenting of artery with a diameter less than 3 mm, using stent length more than 18 mm, as well as when the residual stenosis was more than 12%. Conclusions: We found that EUPES was inferior to SES during the 2-year follow-up with respect to rates of MACE and TLR that were significantly higher in the EUPES than in the SES group.

  5. Enhanced Supersaturation and Oral Absorption of Sirolimus Using an Amorphous Solid Dispersion Based on Eudragit® E

    Directory of Open Access Journals (Sweden)

    Youngseok Cho

    2015-05-01

    Full Text Available The present study aimed to investigate the effect of Eudragit® E/HCl (E-SD on the degradation of sirolimus in simulated gastric fluid (pH 1.2 and to develop a new oral formulation of sirolimus using E-SD solid dispersions to enhance oral bioavailability. Sirolimus-loaded solid dispersions were fabricated by a spray drying process. A kinetic solubility test demonstrated that the sirolimus/E-SD/TPGS (1/8/1 solid dispersion had a maximum solubility of 196.7 μg/mL within 0.5 h that gradually decreased to 173.4 μg/mL after 12 h. According to the dissolution study, the most suitable formulation was the sirolimus/E-SD/TPGS (1/8/1 solid dispersion in simulated gastric fluid (pH 1.2, owing to enhanced stability and degree of supersaturation of E-SD and TPGS. Furthermore, pharmacokinetic studies in rats indicated that compared to the physical mixture and sirolimus/HPMC/TPGS (1/8/1 solid dispersion, the sirolimus/E-SD/TPGS (1/8/1 solid dispersion significantly improved oral absorption of sirolimus. E-SD significantly inhibited the degradation of sirolimus in a dose-dependent manner. E-SD also significantly inhibited the precipitation of sirolimus compared to hydroxypropylmethyl cellulose (HPMC. Therefore, the results from the present study suggest that the sirolimus-loaded E-SD/TPGS solid dispersion has great potential in clinical applications.

  6. Composite outcomes in 2.25-mm drug eluting stents: a systematic review

    International Nuclear Information System (INIS)

    Lee, Justin Z.; Singh, Nirmal; Ortega, Gilbert; Low, See Wei; Kanakadandi, Uday; Fortuin, F. David; Lassar, Tom; Lee, Kwan S.

    2015-01-01

    Background: Coronary atherosclerosis often involves small-caliber coronaries, yet the safety and efficacy of 2.25-mm DES have been poorly defined, with a general lack of separation of 2.25 with 2.5-mm performance. No randomized head-to-head 2.25 mm DES studies have been reported. There are several single-arm prospective studies, and we aim to systematically review all published specific 2.25-mm data to estimate composite DES-specific performance and highlight current knowledge gaps. Methods: We performed a systematic literature search of PubMed, EMBASE, Web of Science and Cochrane database for clinical trials of 2.25-mm DES. Angiographic and composite clinical outcomes were compared with descriptive statistics. Results: 2.25 mm-Paclitaxel (PES), sirolimus (SES), everolimus (EES) and platinum chromium EES DES-specific outcomes have been reported. Death at 12 months for SES, PES, EES and platinum chromium EES was 1.3%, 3.0%, 1.5%, and 4.4%. Rates of target vessel revascularization at 12 months for SES, PES, EES and platinum chromium EES were 5.7%, 13.3%, 8.8%, and 3.3%. Angiographic outcomes at 9 months to one year were as follows: mean late lumen loss (LLL) for SES, PES, and EES was 0.15 ± 0.11-mm, 0.28 ± 0.11-mm, and 0.16 ± 0.41-mm and mean diameter restenosis for SES, PES, and EES were 29.5 ± 6.2%, 34.7 ± 4.2%, and 20.9 ± 22.5%. Reported stent thrombosis rates for 2.25-mm DES were low ranging from 0% to 2.2% in up to 24-months of follow-up. Conclusions: This systematic review summarizes and tabulates all available specific data on 2.25-mm DES. Based on our descriptive analysis, 2.25-mm DESs have a favorable safety and efficacy profile for the treatment of very small coronary lesions. - Highlights: • Safety and efficacy of 2.25-mm DES have been poorly defined. • We performed a systematic review on all published 2.25 mm data to estimate composite DES-specific performance and highlight current knowledge gaps. • We pooled data from 9 clinical studies and 1

  7. Composite outcomes in 2.25-mm drug eluting stents: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Justin Z. [Department of Medicine, University of Arizona, 1501 N Campbell Avenue, Tucson, AZ, 85724 (United States); Singh, Nirmal [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Ortega, Gilbert [College of Medicine, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Low, See Wei; Kanakadandi, Uday [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Fortuin, F. David [Department of Cardiovascular Diseases, Mayo Clinic Arizona, 5777 East Mayo Boulevard, Phoenix, AZ, 85054 (United States); Lassar, Tom [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States); Lee, Kwan S., E-mail: klee@shc.arizona.edu [Department of Cardiovascular Diseases, University of Arizona, 1501 N Campbell Ave, Tucson, AZ, 85724 (United States)

    2015-06-15

    Background: Coronary atherosclerosis often involves small-caliber coronaries, yet the safety and efficacy of 2.25-mm DES have been poorly defined, with a general lack of separation of 2.25 with 2.5-mm performance. No randomized head-to-head 2.25 mm DES studies have been reported. There are several single-arm prospective studies, and we aim to systematically review all published specific 2.25-mm data to estimate composite DES-specific performance and highlight current knowledge gaps. Methods: We performed a systematic literature search of PubMed, EMBASE, Web of Science and Cochrane database for clinical trials of 2.25-mm DES. Angiographic and composite clinical outcomes were compared with descriptive statistics. Results: 2.25 mm-Paclitaxel (PES), sirolimus (SES), everolimus (EES) and platinum chromium EES DES-specific outcomes have been reported. Death at 12 months for SES, PES, EES and platinum chromium EES was 1.3%, 3.0%, 1.5%, and 4.4%. Rates of target vessel revascularization at 12 months for SES, PES, EES and platinum chromium EES were 5.7%, 13.3%, 8.8%, and 3.3%. Angiographic outcomes at 9 months to one year were as follows: mean late lumen loss (LLL) for SES, PES, and EES was 0.15 ± 0.11-mm, 0.28 ± 0.11-mm, and 0.16 ± 0.41-mm and mean diameter restenosis for SES, PES, and EES were 29.5 ± 6.2%, 34.7 ± 4.2%, and 20.9 ± 22.5%. Reported stent thrombosis rates for 2.25-mm DES were low ranging from 0% to 2.2% in up to 24-months of follow-up. Conclusions: This systematic review summarizes and tabulates all available specific data on 2.25-mm DES. Based on our descriptive analysis, 2.25-mm DESs have a favorable safety and efficacy profile for the treatment of very small coronary lesions. - Highlights: • Safety and efficacy of 2.25-mm DES have been poorly defined. • We performed a systematic review on all published 2.25 mm data to estimate composite DES-specific performance and highlight current knowledge gaps. • We pooled data from 9 clinical studies and 1

  8. Restenosis after stenting in symptomatic vertebral arterial orifice disease and considerations for better outcome

    Science.gov (United States)

    Chang, Jun Young; Park, Hyun; Kwon, Oki

    2017-01-01

    We have performed stenting in 11 patients with symptomatic vertebral arterial orifice stenosis refractory to medical treatment or impairment in anterior circulation. Three of the 11 patients experienced asymptomatic severe in-stent restenosis or occlusion. Bare metal stents were used in those three patients, two of whom received revascularization therapy. Development of sufficient cervical collateral channels reconstituting the distal vertebral artery was the common feature in patients with asymptomatic in-stent restenosis. In selecting appropriate stents, consideration of mechanical strength and drug-eluting properties of a stent according to characteristics of the target vessel is important to reduce the risk of in-stent restenosis. Any decision to perform revascularization should be based on the presence of abundant cervical collaterals as well as clinical symptoms of vertebrobasilar ischemia. PMID:28304206

  9. Genetic variants in CCNB1 associated with differential gene transcription and risk of coronary in-stent restenosis

    NARCIS (Netherlands)

    Silvestre-Roig, Carlos; Fernández, Patricia; Mansego, María L.; van Tiel, Claudia M.; Viana, Rosa; Anselmi, Chiara Viviani; Condorelli, Gianluigi; de Winter, Robbert J.; Martín-Fuentes, Paula; Solanas-Barca, María; Civeira, Fernando; Focaccio, Amelia; de Vries, Carlie J. M.; Chaves, Felipe Javier; Andrés, Vicente

    2014-01-01

    The development of diagnostic tools to assess restenosis risk after stent deployment may enable the intervention to be tailored to the individual patient, for example, by targeting the use of drug-eluting stent to high-risk patients, with the goal of improving safety and reducing costs. The CCNB1

  10. Intravitreal Sirolimus for Noninfectious Uveitis: A Phase III Sirolimus Study Assessing Double-masKed Uveitis TReAtment (SAKURA).

    Science.gov (United States)

    Nguyen, Quan Dong; Merrill, Pauline T; Clark, W Lloyd; Banker, Alay S; Fardeau, Christine; Franco, Pablo; LeHoang, Phuc; Ohno, Shigeaki; Rathinam, Sivakumar R; Thurau, Stephan; Abraham, Abu; Wilson, Laura; Yang, Yang; Shams, Naveed

    2016-11-01

    To evaluate the efficacy and safety of intravitreal sirolimus in the treatment of noninfectious uveitis (NIU) of the posterior segment (i.e., posterior, intermediate, or panuveitis). Phase III, randomized, double-masked, active-controlled, 6-month study with intravitreal sirolimus. Adults with active NIU of the posterior segment (intermediate, posterior, or panuveitis), defined as a vitreous haze (VH) score >1+. Subjects discontinued NIU medications before baseline, except for systemic corticosteroids, which were allowed only for those already receiving them at baseline and were rapidly tapered after baseline per protocol. Intravitreal sirolimus assigned 1:1:1 at doses of 44 (active control), 440, or 880 μg, administered on Days 1, 60, and 120. The primary efficacy outcome was the percentage of subjects with VH 0 response at Month 5 (study eye) without use of rescue therapy. Secondary outcomes at Month 5 were VH 0 or 0.5+ response rate, corticosteroid tapering success rate (i.e., tapering to a prednisone-equivalent dosage of ≤5 mg/day), and changes in best-corrected visual acuity (BCVA). Adverse events during the double-masked treatment period are presented. A total of 347 subjects were randomized. Higher proportions of subjects in the intravitreal sirolimus 440 μg (22.8%; P = 0.025) and 880 μg (16.4%; P = 0.182) groups met the primary end point than in the 44 μg group (10.3%). Likewise, higher proportions of subjects in the 440 μg (52.6%; P = 0.008) and 880 μg (43.1%; P = 0.228) groups achieved a VH score of 0 or 0.5+ than in the 44 μg group (35.0%). Mean BCVA was maintained throughout the study in each dose group, and the majority of subjects receiving corticosteroids at baseline successfully tapered off corticosteroids (44 μg [63.6%], 440 μg [76.9%], and 880 μg [66.7%]). Adverse events in the treatment and active control groups were similar in incidence, and all doses were well tolerated. Intravitreal sirolimus 440 μg demonstrated a significant

  11. Synergistic immunosuppressive effects of the mTOR inhibitor sirolimus and the phytochemical curcumin.

    Science.gov (United States)

    Deters, M; Hütten, H; Kaever, V

    2013-01-15

    The immunosuppressant sirolimus and curcumin, the main principle of the turmeric spice, have shown antiproliferative effects on many human and not-human cell lines. Whereas the antiproliferative effect of sirolimus is mainly mediated by inhibition of mTOR, curcumin is described to affect many molecular targets which makes it unpredictable to appraise if the effects of these both substances on cell proliferation and especially on immunosuppression are additive or synergistic. To answer this question we investigated the interaction of both these substances on OKT3-induced human peripheral blood mononuclear cell (PBMC) proliferation. OKT3-induced human PBMC proliferation was determined by measuring (3)H-thymidine incorporation. Influence of curcumin on interleukin-2 (IL-2) release and IκB-phosphorylation in PBMC was determined by ELISA and western blot, respectively. Curcumin-induced apoptosis and necrosis was analyzed by FACS analysis. Whereas curcumin completely inhibited OKT3-induced PBMC proliferation in a dose-dependent manner with an IC(50) of 2.8 μM, sirolimus could reduce PBMC proliferation dose-dependently only to a minimum of 28% at a concentration of 5 ng/ml (IC(50) 1.1 ng/ml). When curcumin was combined at concentrations of 1.25-2.5 μM with sirolimus at concentrations from 0.63 to 1.25 ng/ml the effects were synergistic. Combination of curcumin (1.25-2.5 μM) with sirolimus (5 ng/ml) showed additive effects. The effects after combination of curcumin at 5 μM with each sirolimus concentration and sirolimus at 10 ng/ml with each curcumin concentration were presumably antagonistic. We conclude that the immunosuppressive effects of curcumin and sirolimus in low concentrations are synergistic in OKT3-activated PBMC. Whether curcumin and sirolimus have also synergistic antiproliferative effects in tumor cells has to be shown in further experiments including animal models. Copyright © 2012 Elsevier GmbH. All rights reserved.

  12. Clinical presentation and outcomes of coronary in-stent restenosis across 3-stent generations.

    Science.gov (United States)

    Magalhaes, Marco A; Minha, Sa'ar; Chen, Fang; Torguson, Rebecca; Omar, Al Fazir; Loh, Joshua P; Escarcega, Ricardo O; Lipinski, Michael J; Baker, Nevin C; Kitabata, Hironori; Ota, Hideaki; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2014-12-01

    Clinical presentation of bare metal stent in-stent restenosis (ISR) in patients undergoing target lesion revascularization is well characterized and negatively affects on outcomes, whereas the presentation and outcomes of first- and second-generation drug-eluting stents (DESs) remains under-reported. The study included 909 patients (1077 ISR lesions) distributed as follows: bare metal stent (n=388), first-generation DES (n=425), and second-generation DES (n=96), categorized into acute coronary syndrome (ACS) or non-ACS presentation mode at the time of first target lesion revascularization. ACS was further classified as myocardial infarction (MI) and unstable angina. For bare metal stent, first-generation DES and second-generation DES, ACS was the clinical presentation in 67.8%, 71.0%, and 66.7% of patients, respectively (P=0.470), whereas MI occurred in 10.6%, 10.1%, and 5.2% of patients, respectively (P=0.273). The correlates for MI as ISR presentation were current smokers (odds ratio, 3.02; 95% confidence interval [CI], 1.78-5.13; Ppresentations had an independent effect on major adverse cardiac events (death, MI, and re-target lesion revascularization) at 6 months (MI versus non-ACS: adjusted hazard ratio, 4.06; 95% CI, 1.84-8.94; Pclinical presentation is similar irrespective of stent type. MI as ISR presentation seems to be associated with patient and not device-related factors. ACS as ISR presentation has an independent effect on major adverse cardiac events, suggesting that ISR remains a hazard and should be minimized. © 2014 American Heart Association, Inc.

  13. Relation of body mass index to risk of stent thrombosis after percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Schmiegelow, Michelle; Torp-Pedersen, Christian; Gislason, Gunnar H

    2012-01-01

    Stent thrombosis is a devastating complication after percutaneous coronary intervention (PCI), but the influence of obesity on risk of stent thrombosis is unclear, and it is unknown if this relation is dependent on stent type. The objective of this study was to examine the relation between body...... mass index (BMI) and stent thrombosis after PCI with bare-metal stent (BMS) or drug-eluting stent (DES). We followed 5,515 patients who underwent PCI with implantation of ≥1 BMS or DES at a high-volume tertiary invasive cardiology center from 2000 through 2006. Only patients with a single type of stent...... (BMS or DES) implanted at the index PCI were included. Median follow-up period was 26 months (interquartile range 12 to 44) and definite stent thrombosis occurred in 78 patients. Hazard ratio of definite stent thrombosis adjusted for number of stents at the index PCI was 0.92 (95% confidence interval...

  14. Bone metabolism in renal transplant patients treated with cyclosporine or sirolimus.

    Science.gov (United States)

    Campistol, Josep M; Holt, David W; Epstein, Solomon; Gioud-Paquet, Martine; Rutault, Karine; Burke, James T

    2005-09-01

    Sirolimus is a new immunosuppressive agent used as treatment to prevent acute renal allograft rejection. One of the complications of renal transplantation and subsequent long-term immunosuppression is bone loss associated with osteoporosis and consequent fracture. Two open-label, randomized, phase 2 studies comparing sirolimus versus cyclosporine (CsA) included indices of bone metabolism as secondary end-points. Markers of bone turnover, serum osteocalcin and urinary N-telopeptides, were measured over a 1-year period in 115 patients receiving either CsA or sirolimus as a primary therapy in combination with azathioprine and glucocorticoids (study A) or mycophenolate mofetil (MMF) and glucocorticoids (study B). Urinary excretion of N-telopeptides and the concentrations of serum osteocalcin were consistently higher in the CsA-treated patients and significantly different at week 24 for N-telopeptides and at weeks 12, 24, and 52 for osteocalcin. In conclusion, future trials are warranted to test whether a sirolimus-based regimen conserves bone mineral density compared with a CsA-based regimen.

  15. Efetividade e segurança dos stents farmacológicos em um serviço de cardiologia em Curitiba-PR Efectividad y seguridad de los Stents farmacológicos en un servicio de cardiología en Curitiba-PR Effectiveness and safety of drug-eluting stents in a cardiology clinic in Curitiba, PR, Brazil

    Directory of Open Access Journals (Sweden)

    Chiu Yun Yu Braga

    2010-07-01

    . De esos pacientes, 85 (41,87% eran asintomáticos, y 146 (71,92%, multiarteriales. En las características de las lesiones, 77,45% fueron B2/C (AHA/ACC. Taxus fue implantado en 73,62% de los pacientes. En 381 (81,96%, se constataron stents con diámetro > 2,5 mm. El largo del stent era de BACKGROUND: The effectiveness and safety of drug-eluting stents (DES have still been questioned. OBJECTIVE: The objective of this study was to evaluate the effectiveness and safety of these stents, as well as the incidence of target lesion revascularization (TLR, in addition to identifying possible variables influencing the need for TLR. METHODS: A total of 203 patients from Hospital Costantini who were clinically followed up for one to 3 years were selected. RESULTS: The sample characteristics were as follows: 470 lesions; 171 (84.24% male patients; 54 (26.6% had diabetes; 131 (64.35% had hypertension; 127 (62.56%, dyslipidemia; 40 (19.70% were smokers; and 79 (38.92% had a family history of coronary artery disease. Also: 49 (24.14% patients presented with stable angina; 58 (28.57%, unstable angina; and 6 (2.96%, myocardial infarction. Eighty five (41.87% patients were asymptomatic, and 146 (71.92%, had multivessel disease. As for the characteristics of the lesions, 77.45% were B2/C (AHA/ACC. Taxus was implanted in 73.62% of the patients. Stents with diameter > 2.5 mm were used in 381 (81.96% patients. The stent length was < 30 mm in 67.87% of the lesions, with a mean of 2.3 stents per patient. After follow-up, 19 patients (9.3% underwent TLR. Four patients died (1.97%, two of them of MI (0.98%, one of stroke (0.49%, and one of abdominal aneurysm (0.49%. Also, one patient died of late thrombosis (0.49%, and one of reinfarction (0.49%. In the statistical analysis carried out, only the bifurcation lesions variable reached values close to the statistical significance level, with p < 0.06. CONCLUSION: In conclusion, drug-eluting stents have good effectiveness and safety profiles; the

  16. Attitudes towards drug-eluting stent use and the distribution of motivation type among interventional cardiologists.

    Science.gov (United States)

    Qian, Feng; Phelps, Charles E; Ling, Frederick S; Hannan, Edward L; Veazie, Peter J

    2012-06-01

    The safety of drug-eluting stent (DES) use was called into question in 2006. However, the attitudes towards DES use after DES safety concerns were expressed and the distribution of chronic motivation type among interventional cardiologists are unknown. This study aims to examine the current attitudes towards DES use among interventional cardiologists and to investigate the distribution of chronic motivation type among these doctors. A questionnaire survey of interventional cardiologists was conducted in New York State from October 2008 to April 2009. The questionnaire included face valid items to measure the attitudes towards DES use, valid Regulatory Focus Questionnaire to measure the chronic motivation type, and items collecting demographic information. A total of 119 valid responses were received (response rate: 47%). There were no statistically significant differences regarding the demographic factors between the respondents and the non-respondents. The vast majority of interventional cardiologists (92%) agreed that 'DES is a revolutionary technology' and that 'DES use will increase in the future' (70%). The chronic motivation type of the respondents was predominantly sensitive to positive outcomes (89%). Interventional cardiologists had a very positive attitude regarding DES technology and predicted future growth of DES use. The vast majority of interventional cardiologists were found to be concerned about achieving positive outcomes and wanted to prevent errors of omission. To the best of our knowledge, this is the first study to report the distribution of chronic motivation type among doctors. © 2011 Blackwell Publishing Ltd.

  17. Pioglitazone Attenuates Drug-Eluting Stent-Induced Proinflammatory State in Patients by Blocking Ubiquitination of PPAR

    Directory of Open Access Journals (Sweden)

    Zhongxia Wang

    2016-01-01

    Full Text Available The inflammatory response after polymer-based drug-eluting stent (DES placement has recently emerged as a major concern. The biologic roles of peroxisome proliferator-activated receptor-γ (PPAR-γ activators thiazolidinedione (TZD remain controversial in cardiovascular disease. Herein, we investigated the antiinflammatory effects of pioglitazone (PIO on circulating peripheral blood mononuclear cells (MNCs in patients after coronary DES implantation. Methods and Results. Twenty-eight patients with coronary artery disease and who underwent DES implantations were randomly assigned to pioglitazone (30 mg/d; PIO or placebo (control; Con treatment in addition to optimal standard therapy. After 12 weeks of treatment, plasma concentrations of high-sensitivity C-reactive protein (hs-CRP, interleukin-6 (IL-6, tumor necrosis factor-α (TNF-α, and matrix metalloproteinase-9 (MMP-9 were significantly decreased in PIO group compared to the Con group (P=0.035, 0.011, 0.008, and 0.012, resp.. DES-induced mRNA expressions of IL-6, TNF-α, and MMP-9 in circulating MNC were significantly blocked by PIO (P=0.031, 0.012, and 0.007, resp.. In addition, PIO markedly inhibited DES-enhanced NF-κB function and DES-blocked PPAR-γ activity. Mechanically, DES induced PPAR-γ ubiquitination and degradation in protein level, which can be totally reversed by PIO. Conclusion. PIO treatment attenuated DES-induced PPAR loss, NF-κB activation, and proinflammation, indicating that PIO may have a novel direct protective role in modulating proinflammation in DES era.

  18. A Novel Quantitative Computed Tomographic Analysis Suggests How Sirolimus Stabilizes Progressive Air Trapping in Lymphangioleiomyomatosis.

    Science.gov (United States)

    Argula, Rahul G; Kokosi, Maria; Lo, Pechin; Kim, Hyun J; Ravenel, James G; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X

    2016-03-01

    The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. We determined the baseline to 12-month change in computed tomographic image-derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image-derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. -0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying.

  19. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheng-Hung [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China); Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Jhong, Guan-Heng [Graduate Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan (China); Hsu, Ming-Yi; Wang, Chao-Jan [Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Tao-Yuan, Taiwan (China); Liu, Shih-Jung, E-mail: shihjung@mail.cgu.edu.tw [Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan (China); Hung, Kuo-Chun [Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Chang Gung University College of Medicine, Tao-Yuan, Taiwan (China)

    2014-05-28

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  20. Effect of force-induced mechanical stress at the coronary artery bifurcation stenting: Relation to in-stent restenosis

    International Nuclear Information System (INIS)

    Lee, Cheng-Hung; Jhong, Guan-Heng; Hsu, Ming-Yi; Wang, Chao-Jan; Liu, Shih-Jung; Hung, Kuo-Chun

    2014-01-01

    The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force following stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.

  1. Stented Vessels: A Challenge for Histological Preparation and Microscopy

    Directory of Open Access Journals (Sweden)

    Andrea Nolte

    2013-06-01

    Full Text Available Objective: The first procedure to treat blocked coronary arteries was coronary artery bypass graft surgery. In 1977, Andreas Gruntzig introduced percutaneous transluminal coronary angioplasty (PTCA. Today, several stent systems exist ranging from bare metal stents to various drug-eluting stents. Unfortunately, our understanding of the arterial reaction to stent implantation is incomplete – primarily due to technical limitations in the histological study of stented vascular tissue. Methods: In our study, we examined different histological preparation methods based on the embedding material methacrylate. The procedure of embedding and sectioning stented porcine arteries was optimized for the specific requirements, like histochemistry, immunohistochemistry or pre-stained fluorescence. Furthermore, we used a microscopical technique described as fluorescence intensity decay shape analysis microscopy (FIDSAM to eliminate auto-fluorescence from fluorescently labeled tissue. Results: The sections were suitable for histochemical and immunohistochemical staining. Additionally, pre-labeled fluorescence in the porcine tissue was not lost by the embedding process. The evaluation of arterial cross sections with FIDSAM technology gave new, very important insights into the examination possibilities of fluorescently labeled tissue. Conclusions: Future studies of the vascular response to a variety of new stent materials will provide important clues to the pathogenesis resulting in restenosis and occlusion of stents. [J Interdiscipl Histopathol 2013; 1(3.000: 104-112

  2. Drug-Eluting Nitinol Stent Treatment of the Superficial Femoral Artery and Above-the-Knee Popliteal Artery (The Zilver PTX Single-Arm Clinical Study): A Comparison Between Diabetic and Nondiabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological Sciences (Italy); Primo, Massimiliano Di [Hopital Europeen Georges Pompidou, University Paris Descartes (France); Boatta, Emanuele [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological Sciences (Italy); Johnston, Krystal, E-mail: kjohnston@medinst.com [MED Institute, Inc (United States); Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, University Paris Descartes (France)

    2013-10-15

    Purpose: To describe the 1-year results of drug-eluting nitinol stent placement in the femoropopliteal artery of diabetic and nondiabetic patients. Materials and Methods: All patients enrolled in this prospective, multicenter study underwent paclitaxel-eluting stent placement for de novo or restenotic lesions of the superficial femoral and/or popliteal artery. Baseline and follow-up walking impairment questionnaire (WIQ) scores, Rutherford classifications, and ankle-brachial index (ABI) measurements were obtained. Follow-up was completed at 1, 6, and 12 months. Results: There were 285 diabetic patients and 502 nondiabetic patients treated. There were no significant differences in mean lesion length or lesion calcification between patient groups. Procedural success in both treatment groups was >97 %. There were no significant differences between diabetic and nondiabetic groups in Kaplan-Meier estimates of patency, event-free survival (EFS), or freedom from target lesion revascularization (TLR) at 6 and 12 months. Both groups experienced a significant increase in ABI and WIQ values after treatment, and these improvements were sustained to 12-month follow-up; however, nondiabetic patients had significantly greater 6- and 12-month WIQ scores compared with diabetic patients. Based on covariate analysis, the only factors shown to be significant and to negatively influence patency were longer lesion length (p = 0.009), higher Rutherford classification (p = 0.02), and lack of hypertension (p = 0.02); diabetic status was not found to be a significant factor. Conclusion: Diabetic and nondiabetic patients had similar estimates of primary patency, EFS, and freedom from TLR; however, diabetic patients showed less improvement in WIQ scores compared with nondiabetic patients.

  3. Drug-eluting or bare-metal stents for large coronary vessel stenting? The BASKET-PROVE (PROspective Validation Examination) trial: Study protocol and design

    DEFF Research Database (Denmark)

    Pfisterer, M.; Bertel, O.; Bonetti, P.O.

    2008-01-01

    or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with >= 3.0-mm stents only, randomized to receive Cypher (Johnson & Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only...

  4. Role of metallic stents in benign esophageal stricture

    Science.gov (United States)

    Shim, Chan Sup

    2012-10-01

    Simple esophageal strictures, which are focal, straight, and large in diameter, usually require 1 - 3 dilation sessions to relieve symptoms. However, complex strictures, which are long, tortuous, or associated with a severely compromised luminal diameter, are usually more difficult to treat with conventional bougie or balloon dilation techniques, and often have high recurrence rates. Although the permanent placement of self-expandable metal stents (SEMS) has been used to manage refractory benign esophageal strictures, this procedure is associated with additional problems, such as stricture from tissue hyperplasia, stent migration, and fistula formation. Thus, several new types of stents have been developed, including temporary SEMS, self-expandable plastic stents (SEPS), and biodegradable stents. The use of these new products has produced varied results. Temporary SEMS that have been used to relieve benign esophageal conditions have caused granulation tissue at both ends of the stent because of contact between the mucosa and the exposed metal components of the stent, thus hindering stent removal. We examined the tissue response to two new types of SEMS, a flange-type and a straighttype, each coated with a silicone membrane on the outside of the metal mesh. These two SEMS were evaluated individually and compared with a conventional control stent in animal experiments. Although the newly designed stents resulted in reduced tissue hyperplasia, and were thus more easily separated from the esophageal tissue, some degree of tissue hyperplasia did occur. We suggest that newly designed DES (drug-eluting stents) may provide an alternative tool to manage refractory benign esophageal stricture.

  5. Practical recommendations for the early use of m-TOR inhibitors (sirolimus) in renal transplantation.

    Science.gov (United States)

    Campistol, Josep M; Cockwell, Paul; Diekmann, Fritz; Donati, Donato; Guirado, Luis; Herlenius, Gustaf; Mousa, Dujanah; Pratschke, Johann; San Millán, Juan Carlos Ruiz

    2009-07-01

    m-TOR inhibitors (e.g. sirolimus) are well-tolerated immunosuppressants used in renal transplantation for prophylaxis of organ rejection, and are associated with long-term graft survival. Early use of sirolimus is often advocated by clinicians, but this may be associated with a number of side-effects including impaired wound-healing, lymphoceles and delayed graft function. As transplant clinicians with experience in the use of sirolimus, we believe such side-effects can be limited by tailored clinical management. We present recommendations based on published literature and our clinical experience. Furthermore, guidance is provided on sirolimus use during surgery, both at transplantation and for subsequent operations.

  6. Profiling sirolimus-induced inflammatory syndrome: a prospective tricentric observational study.

    Directory of Open Access Journals (Sweden)

    Fanny Buron

    Full Text Available BACKGROUND: The use of the immunosuppressant sirolimus in kidney transplantation has been made problematic by the frequent occurrence of various side effects, including paradoxical inflammatory manifestations, the pathophysiology of which has remained elusive. METHODS: 30 kidney transplant recipients that required a switch from calcineurin inhibitor to sirolimus-based immunosuppression, were prospectively followed for 3 months. Inflammatory symptoms were quantified by the patients using visual analogue scales and serum samples were collected before, 15, 30, and 90 days after the switch. RESULTS: 66% of patients reported at least 1 inflammatory symptom, cutaneo-mucosal manifestations being the most frequent. Inflammatory symptoms were characterized by their lability and stochastic nature, each patient exhibiting a unique clinical presentation. The biochemical profile was more uniform with a drop of hemoglobin and a concomitant rise of inflammatory acute phase proteins, which peaked in the serum 1 month after the switch. Analyzing the impact of sirolimus introduction on cytokine microenvironment, we observed an increase of IL6 and TNFα without compensation of the negative feedback loops dependent on IL10 and soluble TNF receptors. IL6 and TNFα changes correlated with the intensity of biochemical and clinical inflammatory manifestations in a linear regression model. CONCLUSIONS: Sirolimus triggers a destabilization of the inflammatory cytokine balance in transplanted patients that promotes a paradoxical inflammatory response with mild stochastic clinical symptoms in the weeks following drug introduction. This pathophysiologic mechanism unifies the various individual inflammatory side effects recurrently reported with sirolimus suggesting that they should be considered as a single syndromic entity.

  7. Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography.

    Science.gov (United States)

    Kitahara, Hideki; Waseda, Katsuhisa; Yamada, Ryotaro; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Kobayashi, Yuhei; Okada, Kozo; Kume, Teruyoshi; Nakagawa, Kaori; Teramoto, Tomohiko; Ikeno, Fumiaki; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2016-06-12

    Our aim was to evaluate stent expansion and acute recoil at deployment and post-dilatation, and the impact of post-dilatation strategies on final stent dimensions. Optical coherence tomography (OCT) was performed on eight bare metal platforms of drug-eluting stents (3.0 mm diameter, n=6 for each) during and after balloon inflation in a silicone mock vessel. After nominal-pressure deployment, a single long (30 sec) vs. multiple short (10 sec x3) post-dilatations were performed using a non-compliant balloon (3.25 mm, 20 atm). Stent areas during deployment with original delivery systems were smaller in stainless steel stents than in cobalt-chromium and platinum-chromium stents (pstrategies showed a significant impact on final stent expansion.

  8. Steady-state pharmacokinetics of sirolimus in stable adult Chinese renal transplant patients.

    Science.gov (United States)

    Wang, Huifen Faye; Qiu, Feng; Wu, Xiongfe; Fang, Juanzhi; Crownover, Penelope; Korth-Bradley, Joan; Schulman, Seth

    2014-05-01

    This open-label, nonrandomized study was conducted to evaluate the steady-state pharmacokinetics of sirolimus in 24 stable Chinese renal transplant patients receiving daily oral maintenance doses of sirolimus (1-4 mg). Repeated trough and serial whole blood sirolimus concentrations over a 24-hour dosing interval were collected and assayed using high-performance liquid chromatography with tandem mass spectrometry (HPLC/MS/MS). Non-compartmental analysis (NCA) was employed to calculate sirolimus pharmacokinetic parameters. Cytochrome P450 (CYP) 3A5 genotyping was performed. Cyclosporine (CsA) levels were determined for patients who took concomitant CsA. Mean (±SD) sirolimus maximum concentration (Cmax ), area under the concentration-time curve within a dosing interval of τ (AUCτ ), oral clearance (CL/F), and trough concentration (Ctrough ) at steady state were: 14.1 ± 13.4 ng/mL, 199 ± 210 ng · h/mL, 10.1 ± 4.4 L/h, and 5.9 ± 6.3 ng/mL, respectively. Median tmax (range) was 2.49 hours (1-12 hours). A strong correlation was observed between Ctrough and AUCτ . Pharmacokinetics of sirolimus in patients with and without concomitant CsA were comparable. Allele frequency of CYP3A5*3 was 70.9% and a trend of higher oral clearance was observed in CYP3A5 expressers compared with non-expressers although the number of subjects in each genotype was small. © 2014, The American College of Clinical Pharmacology.

  9. Echocardiographic identification of ventricular septal rupture caused by acute stent thrombosis.

    Science.gov (United States)

    Garg, Scot; Bourantas, Christos V; Thackray, Simon; Alamgir, Mohamed F

    2010-05-01

    Coronary stenting is an increasingly common procedure. Complications are rare. However, when they do occur, they often require urgent invasive treatment. Investigations that are critical for establishing a diagnosis as well as such guide treatment as a detailed assessment of myocardial morphology and function using transthoracic echocardiography may be overlooked in the haste to treat the patient. We present a case report of subacute drug-eluting stent thrombosis in which a meticulous echocardiographic examination allowed the identification of a ventricular septal rupture, which ultimately modified treatment.

  10. Open-Label, Randomized Study of Transition From Tacrolimus to Sirolimus Immunosuppression in Renal Allograft Recipients

    Science.gov (United States)

    Tedesco-Silva, Helio; Peddi, V. Ram; Sánchez-Fructuoso, Ana; Marder, Brad A.; Russ, Graeme R.; Diekmann, Fritz; Flynn, Alison; Hahn, Carolyn M.; Li, Huihua; Tortorici, Michael A.; Schulman, Seth L.

    2016-01-01

    Background Calcineurin inhibitor–associated nephrotoxicity and other adverse events have prompted efforts to minimize/eliminate calcineurin inhibitor use in kidney transplant recipients. Methods This open-label, randomized, multinational study evaluated the effect of planned transition from tacrolimus to sirolimus on kidney function in renal allograft recipients. Patients received tacrolimus-based immunosuppression and then were randomized 3 to 5 months posttransplantation to transition to sirolimus or continue tacrolimus. The primary end point was percentage of patients with 5 mL/min per 1.73 m2 or greater improvement in estimated glomerular filtration rate from randomization to month 24. Results The on-therapy population included 195 patients (sirolimus, 86; tacrolimus, 109). No between-group difference was noted in percentage of patients with 5 mL/min per 1.73 m2 or greater estimated glomerular filtration rate improvement (sirolimus, 34%; tacrolimus, 42%; P = 0.239) at month 24. Sirolimus patients had higher rates of biopsy-confirmed acute rejection (8% vs 2%; P = 0.02), treatment discontinuation attributed to adverse events (21% vs 3%; P renal function improvement at 24 months is similar for patients with early conversion to sirolimus after kidney transplantation versus those remaining on tacrolimus. PMID:27500260

  11. Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.

    Science.gov (United States)

    Mennuni, Marco G; Pagnotta, Paolo A; Stefanini, Giulio G

    2016-02-01

    Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.

  12. Discretionary decisions and disparities in receiving drug-eluting stents under a universal healthcare system: A population-based study.

    Directory of Open Access Journals (Sweden)

    Raymond N Kuo

    Full Text Available One of the main objectives behind the expansion of insurance coverage is to eliminate disparities in health and healthcare. However, researchers have not yet fully elucidated the reasons for disparities in the use of high-cost treatments among patients of different occupations. Furthermore, it remains unknown whether discretionary decisions made at the hospital level have an impact on the administration of high-cost interventions in a universal healthcare system. This study investigated the adoption of drug-eluting stents (DES versus bare metal-stents (BMS among patients in different occupations and income levels, with the aim of gauging the degree to which the inclination of health providers toward treatment options could affect treatment choices at the patient-level within a universal healthcare system.We adopted a cross-sectional observational study design using hierarchical modeling in conjunction with the population-based National Health Insurance database of Taiwan. Patients who received either a BMS or a DES between 2007 and 2010 were included in the study.During the period of study, 42,124 patients received a BMS (65.3% and 22,376 received DES (34.7%. Patients who were physicians or the family members of physicians were far more likely to receive DES (OR: 3.18, CI: 2.38-4.23 than were patients who were neither physicians nor in other high-status jobs (employers, other medical professions, or public service. Similarly, patients in the top 5% income bracket had a higher probability of receiving a DES (OR: 2.23, CI: 2.06-2.47, p 50% or between 25% and 50% was shown to be strongly associated with the selection of DESs (OR: 3.64 CI: 3.24-4.09 and OR: 2.16, CI: 2.01-2.33, respectively.Even under the universal healthcare system in Taiwan, socioeconomic disparities in the use of high-cost services remain widespread. Differences in the care received by patients of lower socioeconomic status may be due to the discretionary decisions of healthcare

  13. Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography

    International Nuclear Information System (INIS)

    Pan, Jingwei; Lu, Zhigang; Wei, Meng; Zhang, Jiayin; Li, Minghua

    2013-01-01

    To evaluate the diagnostic accuracy of Mehran's in-stent restenosis (ISR) classification by coronary computed angiography (CCTA), with reference to invasive coronary angiography (ICA). Consecutive symptomatic patients, who had clinically suspected ISR and implanted stent diameter ≥ 3 mm, were prospectively enrolled in our study. Mehran's classification was employed by CCTA and ICA to classify ISR lesions into four subtypes: focal, diffuse intrastent, diffuse proliferative and total occlusion. CCTA and ICA measurement of lesion length was further compared. Sixty-one patients with 101 implanted stents were included in our study. The overall sensitivity, specificity, PPV and NPV of CCTA diagnosis of binary ISR, as shown by patient-based analysis (n = 61), were 100 % (49/49), 75 % (8/12), 92.45 % (49/53) and 100 % (8/8) respectively. Mehran's classification of CCTA correlated well with ICA findings. The diagnostic accuracy of CCTA for class I, class II, class III and class IV lesions was 92.5 %, 91.67 %, 100 % and 100 % respectively. Lesion length was assessed to be significantly longer with CCTA than with ICA (11.03 ± 5.89 mm versus 8.56 ± 4.99 mm, P < 0.001). Angiographic patterns of in-stent restenosis can be accurately classified by coronary computed angiography. The lesion length measured by CCTA is longer than that assessed by invasive coronary angiography. (orig.)

  14. Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Junker, Anders

    2015-01-01

    to investigate the intra- and interobserver reliability, as well as the intra-catheter reproducibility of quantitative FD-OCT-assessment of morphometric stent parameters and qualitative FD-OCT-evaluation of strut coverage in 10 randomly selected 6-month follow-up Nobori® biolimus-eluting stents (N-BESs). METHODS...... in another 10 N-BESs (219 CSAs and 1860 struts) were independently assessed by one of the analysts. RESULTS: The intraobserver variability with regard to relative difference of mean luminal area and mean stent area at the CSA-level was very low: 0.1%±1.4% and 0.5%±3.2%. Interobserver variability also proved...... (CI): 0.88-0.93, pstented coronary segments, and for qualitative assessment of strut coverage....

  15. Impact of stent diameter and length on in-stent restenosis after DES vs BMS implantation in patients needing large coronary stents-A clinical and health-economic evaluation.

    Science.gov (United States)

    Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R

    2017-02-01

    The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; Pstent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels 15 mm length. © 2016 John Wiley & Sons Ltd.

  16. Effects of sirolimus alone or in combination with cyclosporine A on renal ischemia/reperfusion injury

    Directory of Open Access Journals (Sweden)

    B.J. Pereira

    2010-08-01

    Full Text Available Calcineurin inhibitors exacerbate ischemic injury in transplanted kidneys, but it is not known if sirolimus protects or exacerbates the transplanted kidney from ischemic injury. We determined the effects of sirolimus alone or in combination with cyclosporin A (CsA on oxygenated and hypoxic/reoxygenated rat proximal tubules in the following in vitro groups containing 6-9 rats per group: sirolimus (10, 50, 100, 250, 500, and 1000 ηg/mL; CsA (100 µg/mL; sirolimus (50 and 250 ηg/mL + CsA (100 µg/mL; control; vehicle (20% ethanol. For in vivo studies, 3-week-old Wistar rats (150-250 g were submitted to left nephrectomy and 30-min renal artery clamping. Renal function and histological evaluation were performed 24 h and 7 days after ischemia (I in five groups: sham, I, I + SRL (3 mg·kg-1·day-1, po, I + CsA (3 mg·kg-1·day-1, sc, I + SRL + CsA. Sirolimus did not injure oxygenated or hypoxic/reoxygenated proximal tubules and did not potentiate the tubular toxic effects of CsA. Neither drug affected the glomerular filtration rate (GFR at 24 h. GFR was reduced in CsA-treated rats on day 7 (0.5 ± 0.1 mL/min but not in rats receiving sirolimus + CsA (0.8 ± 0.1 mL/min despite the reduction in renal blood flow (3.9 ± 0.5 mL/min. Acute tubular necrosis regeneration was similar for all groups. Sirolimus alone was not toxic and did not enhance hypoxia/reoxygenation injury or CsA toxicity to proximal tubules. Despite its hemodynamic effects, sirolimus protected post-ischemic kidneys against CsA toxicity.

  17. Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics

    Science.gov (United States)

    Gundogan, Buket; Tan, Aaron; Farhatnia, Yasmin; Alavijeh, Mohammad S.; Cui, Zhanfeng; Seifalian, Alexander M.

    2014-01-01

    Percutaneous coronary intervention (PCI) is one of the most commonly performed invasive medical procedures in medicine today. Since the first coronary balloon angioplasty in 1977, interventional cardiology has seen a wide array of developments in PCI. Bare metal stents (BMS) were soon superseded by the revolutionary drug-eluting stents (DES), which aimed to address the issue of restenosis found with BMS. However, evidence began to mount against DES, with late-stent thrombosis (ST) rates being higher than that of BMS. The bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the body. This temporary presence provides no triggers for ST, which is brought about by non-endothelialized stent struts and drug polymers remaining in vivo for extended periods of time. Likewise, nano-theranostics incorporated into a bioabsorbable stent of the future may provide an incredibly valuable single platform offering both therapeutic and diagnostic capabilities. Such a stent may allow delivery of therapeutic particles to specific sites thus keeping potential toxicity to a minimum, improved ease of tracking delivery in vivo by embedding imaging agents, controlled rate of therapy release and protection of the implanted therapy. Indeed, nanocarriers may allow an increased therapeutic index as well as offer novel post-stent implantation imaging and diagnostic methods for atherosclerosis, restenosis and thrombosis. It is envisioned that a nano-theranostic stent may well form the cornerstone of future stent designs in clinical practice. PMID:24672583

  18. A retrospective 15-year review: survival advantage after switching to sirolimus in hepatitis C virus infected liver graft recipients.

    Science.gov (United States)

    Shah, M; Shankar, A; Gee, I; Nash, K; Hoare, M; Gibbs, P; Davies, S; Alexander, G J M

    2015-02-01

    The use of sirolimus-based immune suppression in liver transplantation, particularly in hepatitis C virus (HCV)-infected recipients, remains contentious. There is some evidence that sirolimus retards hepatic fibrosis, is renal sparing and may be of benefit in preventing hepatocellular carcinoma (HCC) recurrence. Sirolimus has not been adopted by many transplant centres because of persistent concerns regarding an increased risk of hepatic artery thrombosis, graft loss and death with de novo sirolimus. To review the impact of switching to sirolimus monotherapy in HCV-infected liver recipients with respect to survival, graft loss and hepatic fibrosis. A retrospective review of 190 patients from a single centre undergoing first liver transplantation for HCV over 15 years. 113 patients were switched from calcineurin inhibitor (CNI)-based therapy to low-dose sirolimus monotherapy at a median of 15 months after transplantation for HCV-related fibrosis (72%), renal impairment (14%) or high-risk HCC (5%). Patients switched to sirolimus had improved survival (P diabetes (P = 0.03). These data suggest selective switching to low-dose sirolimus monotherapy in HCV-positive liver recipients improves clinical outcome. © 2014 John Wiley & Sons Ltd.

  19. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Mayer, T.E. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Henkes, H. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany); Kis, B. [Department of Neurology, Alfried Krupp Hospital, Essen (Germany) and Department of Psychiatry and Psychotherapy, University of Duisburg-Essen, Virchow Street 174, D-45147 Essen (Germany)]. E-mail: bernhard.kis@uni-duisburg-essen.de; Hamann, G.F. [Department of Neurology, Klinikum Grosshadern, University of Munich (Germany); Holtmannspoetter, M. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Brueckmann, H. [Department of Neuroradiology, Klinikum Grosshadern, University of Munich (Germany); Kuehne, D. [Department of Radiology and Neuroradiology, Alfried Krupp Hospital, Essen (Germany)

    2005-11-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.

  20. Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery

    International Nuclear Information System (INIS)

    Weber, W.; Mayer, T.E.; Henkes, H.; Kis, B.; Hamann, G.F.; Holtmannspoetter, M.; Brueckmann, H.; Kuehne, D.

    2005-01-01

    Background: To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Methods: Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. Results: The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Conclusions: Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found

  1. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    revascularization rate of 23.8% which was below the 30% cut point of the study protocol. No myocardial Q wave infarction or death were reported. The primary endpoint was reached. During the follow-up period, vasomotion was tested in some of the patients. The proof of principle was confirmed: restoration of vasomotion during acetylcholine testing. The development of the absorbable magnesium stent, which was pushed forward by B. Heublein, Hanover, Germany, has been successful and opens new possibilities for treatment of coronary arteries. Permanent foreign-body implantation is avoided allowing further revascularization procedures in the future, bypass grafting, and restoration of vasomotion. Even prophylactic stenting in nonsignificant stenosis, like vulnerable lesions, may become a regular procedure. Noninvasive coronary imaging by CT and MRI is now possible. Stenting of children and in peripheral arteries may become a standard procedure. Currently, the degradation process of the magnesium stent has to be prolonged, and the neointima proliferation rate has to be reduced so that the DREAM (Drug-Eluting Absorbable Magnesium Stent) concept of Ron Waksman, Washington, DC, USA, can be realized.

  2. Resultados de los stents Resolute Integrity y Promus Element en el infarto de miocardio : análisis del ensayo aleatorizado DUTCH PEERS (TWENTE II)

    NARCIS (Netherlands)

    van Houwelingen, Gert K.; Lam, Ming Kai; Löwik, Marije M.; Danse, Peter W.; Tjon Joe Gin, R. Melvyn; Jessurun, Gillian A.; Anthonio, Rutger L.; Sen, Hanim; Linssen, Gerard C.M.; IJzerman, Maarten J.; Doggen, Carine J.M.; von Birgelen, Clemens

    2016-01-01

    Introduction and objectives In acute myocardial infarction (MI), novel highly deliverable drug-eluting stents (DES) may be particularly valuable as their flexible stent designs might reduce device-induced traumas to culprit lesions. The aim of the study was to assess the safety and efficacy of

  3. In-situ investigation of stress conditions during expansion of bare metal stents and PLLA-coated stents using the XRD sin(2)ψ-technique.

    Science.gov (United States)

    Kowalski, Wolfgang; Dammer, Markus; Bakczewitz, Frank; Schmitz, Klaus-Peter; Grabow, Niels; Kessler, Olaf

    2015-09-01

    Drug eluting stents (DES) consist of platform, coating and drug. The platform often is a balloon-expandable bare metal stent made of the CoCr alloy L-605 or stainless steel 316 L. The function of the coating, typically a permanent polymer, is to hold and release the drug, which should improve therapeutic outcome. Before implantation, DES are compressed (crimped) to allow implantation in the human body. During implantation, DES are expanded by balloon inflation. Crimping, as well as expansion, causes high stresses and high strains locally in the DES struts, as well as in the polymer coating. These stresses and strains are important design criteria of DES. Usually, they are calculated numerically by finite element analysis (FEA), but experimental results for validation are hardly available. In this work, the X-ray diffraction (XRD) sin(2)ψ-technique is applied to in-situ determination of stress conditions of bare metal L-605 stents, and Poly-(L-lactide) (PLLA) coated stents. This provides a realistic characterization of the near-surface stress state and a validation option of the numerical FEA. XRD-results from terminal stent struts of the bare metal stent show an increasing compressive load stress in tangential direction with increasing stent expansion. These findings correlate with numerical FEA results. The PLLA-coating also bears increasing compressive load stress during expansion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Frequency of Cardiac Death and Stent Thrombosis in Patients With Chronic Obstructive Pulmonary Disease Undergoing Percutaneous Coronary Intervention (from the BASKET-PROVE I and II Trials)

    DEFF Research Database (Denmark)

    Jatene, Tannas; Biering-Sørensen, Tor; Nochioka, Kotaro

    2017-01-01

    Chronic obstructive pulmonary disease (COPD) is associated with long-term all-cause death after percutaneous coronary intervention with bare-metal stents. Regarding other outcomes, previous studies have shown conflicting results and the impact of drug-eluting stent (DES) in this population is not...

  5. A stent for co-delivering paclitaxel and nitric oxide from abluminal and luminal surfaces: Preparation, surface characterization, and in vitro drug release studies

    Energy Technology Data Exchange (ETDEWEB)

    Gallo, Annemarie; Mani, Gopinath, E-mail: Gopinath.Mani@usd.edu

    2013-08-15

    Most drug-eluting stents currently available are coated with anti-proliferative drugs on both abluminal (toward blood vessel wall) and luminal (toward lumen) surfaces to prevent neointimal hyperplasia. While the abluminal delivery of anti-proliferative drugs is useful for controlling neointimal hyperplasia, the luminal delivery of such drugs impairs or prevents endothelialization which causes late stent thrombosis. This research is focused on developing a bidirectional dual drug-eluting stent to co-deliver an anti-proliferative agent (paclitaxel – PAT) and an endothelial cell promoting agent (nitric oxide – NO) from abluminal and luminal surfaces of the stent, respectively. Phosphonoacetic acid, a polymer-free drug delivery platform, was initially coated on the stents. Then, the PAT and NO donor drugs were co-coated on the abluminal and luminal stent surfaces, respectively. The co-coating of drugs was collectively confirmed by the surface characterization techniques such as Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), 3D optical surface profilometry, and contact angle goniometry. SEM showed that the integrity of the co-coating of drugs was maintained without delamination or cracks formation occurring during the stent expansion experiments. In vitro drug release studies showed that the PAT was released from the abluminal stent surfaces in a biphasic manner, which is an initial burst followed by a slow and sustained release. The NO was burst released from the luminal stent surfaces. Thus, this study demonstrated the co-delivery of PAT and NO from abluminal and luminal stent surfaces, respectively. The stent developed in this study has potential applications in inhibiting neointimal hyperplasia as well as encouraging luminal endothelialization to prevent late stent thrombosis.

  6. A stent for co-delivering paclitaxel and nitric oxide from abluminal and luminal surfaces: Preparation, surface characterization, and in vitro drug release studies

    International Nuclear Information System (INIS)

    Gallo, Annemarie; Mani, Gopinath

    2013-01-01

    Most drug-eluting stents currently available are coated with anti-proliferative drugs on both abluminal (toward blood vessel wall) and luminal (toward lumen) surfaces to prevent neointimal hyperplasia. While the abluminal delivery of anti-proliferative drugs is useful for controlling neointimal hyperplasia, the luminal delivery of such drugs impairs or prevents endothelialization which causes late stent thrombosis. This research is focused on developing a bidirectional dual drug-eluting stent to co-deliver an anti-proliferative agent (paclitaxel – PAT) and an endothelial cell promoting agent (nitric oxide – NO) from abluminal and luminal surfaces of the stent, respectively. Phosphonoacetic acid, a polymer-free drug delivery platform, was initially coated on the stents. Then, the PAT and NO donor drugs were co-coated on the abluminal and luminal stent surfaces, respectively. The co-coating of drugs was collectively confirmed by the surface characterization techniques such as Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), 3D optical surface profilometry, and contact angle goniometry. SEM showed that the integrity of the co-coating of drugs was maintained without delamination or cracks formation occurring during the stent expansion experiments. In vitro drug release studies showed that the PAT was released from the abluminal stent surfaces in a biphasic manner, which is an initial burst followed by a slow and sustained release. The NO was burst released from the luminal stent surfaces. Thus, this study demonstrated the co-delivery of PAT and NO from abluminal and luminal stent surfaces, respectively. The stent developed in this study has potential applications in inhibiting neointimal hyperplasia as well as encouraging luminal endothelialization to prevent late stent thrombosis.

  7. gender-specific outcome after paclitaxel-eluting stent implantation in japanese patients with coronary artery disease--sub-analysis of the Japan TAXUS Express2 post-marketing survey.

    Science.gov (United States)

    Okura, Hiroyuki; Nakamura, Masato; Kotani, Jun-Ichi; Kozuma, Ken

    2013-01-01

     Although previous randomized and non-randomized studies have demonstrated the safety and efficacy of paclitaxel-eluting stents (PES), a higher revascularization rate has been reported in women than in men. A sub-analysis of the TAXUS Japan Post-market Surveillance Study (TAXUS-PMS) was done to assess the influence of gender on clinical outcome.  A total of 2,132 PES-treated Japanese patients (women, n=551) from this registry were analyzed. Subjects were stratified by gender to compare 1-year clinical outcome. PES-treated women were older and more likely to have insulin-treated diabetes and hypertension. In contrast, PES-treated men were more likely to be smokers, have a previous history of myocardial infarction, and lower ejection fraction. While cardiac death, myocardial infarction and stent thrombosis were similar between men and women, major cardiac events tended to be lower in women than in men (6.4% vs. 8.8%, P=0.08). Although women had significantly smaller reference vessel size (2.46±0.53 mm vs. 2.59±0.60 mm, Ptarget lesion revascularization rate was significantly lower in women than in men (4.2% vs. 6.5%, P<0.05).  Despite a higher risk profile, Japanese women treated with PES did not have a higher rate of repeat revascularization or major adverse clinical outcome than PES-treated men at 1 year. 

  8. Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?

    Science.gov (United States)

    Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi

    2010-06-01

    The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.

  9. Accelerated Recovery of Endothelium Function after Stent Implantation with the Use of a Novel Systemic Nanoparticle Curcumin

    Directory of Open Access Journals (Sweden)

    Qi Lu

    2015-01-01

    Full Text Available Curcumin was reported to exhibit a wide range of pharmacological effects including antioxidant, anti-inflammatory, and antiproliferative activities and significantly prevent smooth muscle cells migration. In the present study, a novel kind of curcumin loaded nanoparticles (Cur-NP has been prepared and characterized with the aim of inhibiting inflammation formation and accelerating the healing process of the stented arteries. Cur-NP was administrated intravenously after stent implantation twice a week and detailed tissue responses were evaluated. The results demonstrated that intravenous administration of Cur-NP after stent implantation accelerated endothelial cells restoration and endothelium function recovery and may potentially be an effective therapeutic alternative to reduce adverse events for currently available drug eluting stents.

  10. Are all stents equal – Need for scoring system to evaluate stents?

    Directory of Open Access Journals (Sweden)

    Sundeep Mishra

    2016-09-01

    Full Text Available Currently drug eluting stents (DES have reached a high degree of sophistication where there seems very little scope of improvement. Even so every year or so there is some advancement in technology and a new version is released, which is claimed to be a new generation (rather than pipeline innovation. It is really important to define what pipeline extension is and what is new innovation (generation? This classification would not only be useful from regulatory perspective but also determining the true value of a product allowing for a correct pricing, which should ideally be able to mark-up for a real innovation.

  11. The study of drug eluting biodegradable intravascular stent with antiproliferation agent-paclitaxel in preventing vascular restenosis

    International Nuclear Information System (INIS)

    Xiao Yueyong; Zhang Jinshan; Cui Fuzhai; Meng Bo

    2004-01-01

    Objective: To define the effect of drug eluting BIS with antiproliferation agent-paclitaxel in preventing vascular restenosis. Methods: Bare BIS and drug BIS with 60 μg paclitaxel were prepared. Both types of the BIS were implanted into the infrarenal restenosis aortas in canine models, and the animals were euthanized 6 weeks after implantation for histopathological, morphometric and immunohistochemical assessment. Results: The mean lumen area of bare BIS group was (77 586.5 ± 66.0) μm 2 , and lumen of paclitaxel eluting BIS group was (113 435.9 ±71.0) μm 2 . The mean neointima area of bare BIS group was (24 803 ± 56) μm 2 , and paclitaxel eluting BIS group was (12 931 ± 63) μm 2 . The PCNA-positive ratio was (38 ± 15)% in bare BIS group and (11 ± 0.31)% in paclitaxel eluting BIS group. The statistically significant difference between the two groups were noted (P<0.01). Conclusion: BIS as a vehicle of loading and releasing drugs could significantly inhibit the VSMC and neointimal hyperplasia with antiproliferation agent-paclitaxel. BIS is a promising and new strategy in preventing the restenosis

  12. High coronary calcium score and post-procedural CK-MB are noninvasive predictors of coronary stent restenosis

    Directory of Open Access Journals (Sweden)

    Lee JB

    2017-02-01

    Full Text Available Jae-Beom Lee,1 Yun-Seok Choi,2 Woo-Baek Chung,2 Ami Kwon,2 Chul-Soo Park,2 Man-Young Lee2 1Anyang Sam Hospital, 2Division of Cardiology, Department of Internal Medicine, Youido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea Purpose: High coronary calcium score (CCS and post-procedural cardiac enzyme may be related with poor outcomes in patients with coronary stent implantation. Methods: A total of 1,072 patients (63.2% male, mean age: 61.7±10.3 years who underwent coronary multi-detect computed tomography at index procedure and follow-up coronary angiography (CAG after drug-eluting stent (DES were divided into two groups: those with and without target lesion revascularization (TLR; >50% reduction in luminal stent diameter or angina symptoms on follow-up CAG. The CCSs for predicting stent revascularization were elucidated. Results: There were no significant differences between the two groups with regard to risk factors. The initial CCS was significantly higher in the TLR group (1,102.4±743.7 vs 345.8±51.05, P=0.04. After adjustment of significant factors for TLR, only CCS and post-procedural creatine kinase MB form (CK-MB elevation were significant predictors of coronary artery TLR. Receiver operation curve revealed that >800 in CCS had 69% in sensitivity and 88% in specificity about predicting the TLR. Conclusion: High CCS with post-procedural CK-MB might be the useful predictors for TLR after DES implantation. Keywords: coronary restenosis, drug-eluting stents, calcium, creatine kinase

  13. Impact of lesion morphology on angiographic and clinical outcomes in patients with chronic total occlusion after recanalization with drug-eluting stents: a multislice computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Tsuyoshi [Toyohashi Heart Center, Toyohashi (Japan); Nagoya City University Graduate School of Medical Sciences, Department of Cardio-Renal Medicine and Hypertension, Nagoya (Japan); Tsuchikane, Etsuo; Nasu, Kenya; Kimura, Masashi; Terashima, Mitsuyasu; Kinoshita, Yoshihisa; Habara, Maoto; Suzuki, Takahiko [Toyohashi Heart Center, Toyohashi (Japan); Suzuki, Yoriyasu; Ehara, Mariko [Nagoya Heart Center, Nagoya (Japan); Ohte, Nobuyuki [Nagoya City University Graduate School of Medical Sciences, Department of Cardio-Renal Medicine and Hypertension, Nagoya (Japan)

    2015-10-15

    The aim of this study was to investigate the multislice computed tomography (MSCT) parameters associated with adverse outcomes after chronic total occlusion percutaneous coronary intervention (CTO-PCI) with drug-eluting stents. A total of 285 patients who underwent MSCT before CTO-PCI were analyzed. Lesion morphology was assessed with MSCT. Angiographic restenosis, reocclusion, and MACE (a composite of cardiac death, myocardial infarction, stent thrombosis, and target lesion revascularization) were analyzed. MACE was observed in 36 patients (13.6 %). Occlusion length was greater (39.5 ± 19.9 mm vs. 22.3 ± 13.7 mm, p < 0.01), minimal vessel area smaller (11.2 ± 5.7 mm{sup 2} vs. 14.5 ± 5.6 mm{sup 2}, p < 0.01), and severe calcification more common (36 % vs. 12 %, p < 0.01) in the MACE group compared to the non-MACE group. We defined occluded length >25.4 mm, minimal vessel area <11.9 mm{sup 2}, which were identified by receiver operating characteristic analysis, and severe calcification as CT-derived risk factors. Angiographic restenosis (60 % vs. 12 % vs. 7 %, p < 0.01), reocclusion (29 % vs. 2 % vs. 2 %, p < 0.01), and MACE (43 % vs. 6 % vs. 3 %, p < 0.01) were more common in patients with 2 or more risk factors than in those with 1 or 0. MSCT characteristics associated with adverse outcomes after CTO-PCI were occlusion length, minimal vessel area, and severe calcification. (orig.)

  14. Sirolimus Associated with Tacrolimus at Low Doses in Elderly Kidney Transplant Patients: A Prospective Randomized Controlled Trial.

    Science.gov (United States)

    Kojima, Cristiane Akemi; Nga, Hong Si; Takase, Henrique Mochida; Bravin, Ariane Moyses; Martinez Garcia, Márcia de Fátima Faraldo; Garcia, Paula Dalsoglio; Contti, Mariana Moraes; de Andrade, Luis Gustavo Modelli

    2018-06-01

    There is no consensus on the best immunosuppressive regimen for elderly renal transplant recipients. The objective of this study was to assess cytomegalovirus infection incidence and kidney transplant outcomes in elderly recipients treated with mammalian target of rapamycin inhibitors sirolimus/ tacrolimus at low doses compared with those receiving tacrolimus/mycophenolate sodium. In this single-center prospective randomized study (Trial Registration No. NCT02683291), kidney transplant recipients over 60 years of age were randomly allocated into 2 groups: tacrolimus-sirolimus (21 patients) and tacrolimus-mycophenolate (23 patients). Cytomegalovirus infection rate and patient survival, biopsy-proven acute rejection, and renal function at 12 months were assessed. Cytomegalovirus infection rate was higher in the mycophenolate group (60.9%) than in the sirolimus group (16.7%; P = .004). The rates of biopsy-proven acute rejection, patient survival, graft survival, and estimated glomerular filtration rate over 12 months did not significantly differ between groups. The incidence of cytomegalovirus infection was significantly lower in the sirolimus group. The use of tacrolimus combined with sirolimus in elderly kidney transplant recipients is safe.

  15. Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.

    Science.gov (United States)

    Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki

    2017-10-01

    Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.

  16. Evaluation of the short- and long-term safety and therapy outcomes of the everolimus-eluting bioresorbable vascular scaffold system in patients with coronary artery stenosis: Rationale and design of the German–Austrian ABSORB RegIstRy (GABI-R)

    Energy Technology Data Exchange (ETDEWEB)

    Nef, Holger, E-mail: holger.nef@innere.med.uni-giessen.de [University of Giessen, Medizinische Klinik I, Department of Cardiology, Giessen (Germany); Wiebe, Jens [University of Giessen, Medizinische Klinik I, Department of Cardiology, Giessen (Germany); Achenbach, Stefan [University of Erlangen, Medizinische Klinik II, Department of Cardiology, Erlangen (Germany); Münzel, Thomas [Department of Medicine II, University Medical Center, Johannes Gutenberg University Mainz, Mainz (Germany); Naber, Christoph [Klinik für Kardiologie und Angiologie, Elisabeth-Krankenhaus, Essen (Germany); Richardt, Gert [Herzzentrum, Segeberger Kliniken GmbH, Bad Segeberg (Germany); Mehilli, Julinda [Department of Cardiology, Klinikum Großhadern, Ludwig- Maximilian Universität, Munich (Germany); Wöhrle, Jochen [Department of Internal Medicine II, University of Ulm, Ulm (Germany); Neumann, Till; Biermann, Janine [University of Essen, Department of Cardiology, Essen (Germany); Zahn, Ralf [Abteilung für Kardiologie, Herzzentrum Ludwigshafen, Ludwigshafen (Germany); Kastner, Johannes [Department of Cardiology, University of Vienna Medical School, Vienna (Austria); Schmermund, Axel [CCB, Cardioangiologisches Centrum Bethanien, Frankfurt (Germany); Pfannebecker, Thomas [Abbott Vascular Deutschland GmbH, Wetzlar (Germany); Schneider, Steffen; Limbourg, Tobias [Institut für Herzinfarktforschung, Ludwigshafen (Germany); Hamm, Christian W. [University of Giessen, Medizinische Klinik I, Department of Cardiology, Giessen (Germany); Kerckhoff Heart and Thorax Center, Department of Cardiology, Bad Nauheim (Germany)

    2016-01-15

    Background: Third-generation drug-eluting metal stents are the gold standard for treatment of coronary artery disease. The permanent metallic caging of the vessel, however, can result in limited vasomotion, chronic inflammation, and late expansive remodeling, conditions that can lead to late and very late stent thrombosis. The development of bioresorbable scaffolds (BRSs) promises advantages over metal stents due to complete biodegradation within 2–4 years. Theoretically, since vessel scaffolding is temporary and no permanent implant remains in the vessel, BRSs, as opposed to metal stents, once degraded would no longer be potential triggers for stent-related adverse events or side effects. Methods/design: The short- and long-term outcome after implantation of an everolimus-eluting, poly-L-lactic acid-based bioresorbable scaffold system (ABSORB, Abbott Vascular, Santa Clara, CA, USA) in the world-wide greatest all-comers cohort will be evaluated in the prospective, non-interventional, multicenter German–Austrian ABSORB RegIstRy (GABI-R). GABI-R will include over 5000 patients from about 100 study sites in Austria and Germany. Safety endpoints such as cardiac death, myocardial infarction, and clinically driven percutaneous or surgical target lesion and vessel revascularization will be evaluated during hospitalization and in the follow-up period (minimum of 5 years). Conclusion: Although two randomized controlled trials and several registries have documented safety and efficacy as well as non-inferiority of this everolimus-eluting ABSORB device compared with drug-eluting metal stents, the current knowledge regarding clinical application, treatment success, and long-term safety of using this BRS in daily routine is limited. Thus, the goal of GABI-R is to address this lack of information. - Highlights: • The GABI-R addresses a lack of data about bioresorbable scaffolds in daily practice. • 5000 patients with minimal in- and exclusion criteria at 100 sites will

  17. Evaluation of the short- and long-term safety and therapy outcomes of the everolimus-eluting bioresorbable vascular scaffold system in patients with coronary artery stenosis: Rationale and design of the German–Austrian ABSORB RegIstRy (GABI-R)

    International Nuclear Information System (INIS)

    Nef, Holger; Wiebe, Jens; Achenbach, Stefan; Münzel, Thomas; Naber, Christoph; Richardt, Gert; Mehilli, Julinda; Wöhrle, Jochen; Neumann, Till; Biermann, Janine; Zahn, Ralf; Kastner, Johannes; Schmermund, Axel; Pfannebecker, Thomas; Schneider, Steffen; Limbourg, Tobias; Hamm, Christian W.

    2016-01-01

    Background: Third-generation drug-eluting metal stents are the gold standard for treatment of coronary artery disease. The permanent metallic caging of the vessel, however, can result in limited vasomotion, chronic inflammation, and late expansive remodeling, conditions that can lead to late and very late stent thrombosis. The development of bioresorbable scaffolds (BRSs) promises advantages over metal stents due to complete biodegradation within 2–4 years. Theoretically, since vessel scaffolding is temporary and no permanent implant remains in the vessel, BRSs, as opposed to metal stents, once degraded would no longer be potential triggers for stent-related adverse events or side effects. Methods/design: The short- and long-term outcome after implantation of an everolimus-eluting, poly-L-lactic acid-based bioresorbable scaffold system (ABSORB, Abbott Vascular, Santa Clara, CA, USA) in the world-wide greatest all-comers cohort will be evaluated in the prospective, non-interventional, multicenter German–Austrian ABSORB RegIstRy (GABI-R). GABI-R will include over 5000 patients from about 100 study sites in Austria and Germany. Safety endpoints such as cardiac death, myocardial infarction, and clinically driven percutaneous or surgical target lesion and vessel revascularization will be evaluated during hospitalization and in the follow-up period (minimum of 5 years). Conclusion: Although two randomized controlled trials and several registries have documented safety and efficacy as well as non-inferiority of this everolimus-eluting ABSORB device compared with drug-eluting metal stents, the current knowledge regarding clinical application, treatment success, and long-term safety of using this BRS in daily routine is limited. Thus, the goal of GABI-R is to address this lack of information. - Highlights: • The GABI-R addresses a lack of data about bioresorbable scaffolds in daily practice. • 5000 patients with minimal in- and exclusion criteria at 100 sites will

  18. Quantitative determination of sirolimus in dog blood using liquid chromatography-tandem mass spectrometry, and its applications to pharmacokinetic studies.

    Science.gov (United States)

    Lee, Jong-Hwa; Cha, Kwang-Ho; Cho, Wonkyung; Park, Junsung; Park, Hee Jun; Cho, Youngseok; Hwang, Sung-Joo

    2010-12-01

    A rapid, sensitive method of detecting sirolimus in blood was developed and applied in pharmacokinetic studies employing deionized water for hemolysis and a weakly basic mobile phase to enhance chromatographic peak intensity. Dog blood samples were processed via liquid-liquid extraction and the amounts of sirolimus and tacrolimus, an internal standard, were quantified by LC-MS/MS. Specificity, the lower limit of quantification, linearity, accuracy, precision, dilution, recovery, matrix effects, robustness and stability were within the acceptable range for assay validation. The concentration of sirolimus was quantifiable in blood samples for up to 36 h after the dog had received a 3 mg/kg dose of sirolimus. These observations suggest that sirolimus can be detected at low levels in dog blood using a basic mobile phase and metal-free hemolysis. This method is therefore applicable to pharmacokinetic studies in dogs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  19. Design of the exhale airway stents for emphysema (EASE) trial : an endoscopic procedure for reducing hyperinflation

    NARCIS (Netherlands)

    Shah, Pallav L.; Slebos, Dirk-Jan; Cardoso, Paulo F. G.; Cetti, Edward J.; Sybrecht, Gerhard W.; Cooper, Joel D.

    2011-01-01

    Background: Airway Bypass is a catheter-based, bronchoscopic procedure in which new passageways are created that bypass the collapsed airways, enabling trapped air to exit the lungs. The Exhale Airway Stents for Emphysema (EASE) Trial was designed to investigate whether Exhale (R) Drug-Eluting

  20. Efficiency of sirolimus in prevention of adhesions around vascular

    African Journals Online (AJOL)

    muhip kanko

    Conclusions: Therefore, sirolimus applied around the prosthesis in vascular operations, was determined ... The total score was calculated for each of the test subjects in the statistical assessment. .... occlusion following aortofemoral bypass for.

  1. Sirolimus influence on hepatectomy-induced liver regeneration in rats

    Directory of Open Access Journals (Sweden)

    Edimar Leandro Toderke

    Full Text Available OBJECTIVE: To evaluate the influence of sirolimus on liver regeneration triggered by resection of 70% of the liver of adult rats. METHODS: we used 40 Wistar rats randomly divided into two groups (study and control, each group was divided into two equal subgroups according to the day of death (24 hours and seven days. Sirolimus was administered at a dose of 1mg/kg in the study group and the control group was given 1 ml of saline. The solutions were administered daily since three days before hepatectomy till the rats death to removal of the regenerated liver, conducted in 24 hours or 7 days after hepatectomy. Liver regeneration was measured by the KWON formula, by thenumber of mitotic figures (hematoxylin-eosin staining and by the immunohistochemical markers PCNA and Ki-67. RESULTS: there was a statistically significant difference between the 24h and the 7d groups. When comparing the study and control groups in the same period, there was a statistically significant variation only for Ki-67, in which there were increased numbers of hepatocytes in cell multiplication in the 7d study group compared with the 7d control group (p = 0.04. CONCLUSION: there was no negative influence of sirolimus in liver regeneration and there was a positive partial effect at immunohistochemistry with Ki-67.

  2. Pulmonary lymphangioleiomyomatosis presenting as spontaneous pneumothorax treated with sirolimus - A case report

    Science.gov (United States)

    Verma, Ajay Kumar; Joshi, Ambarish; Mishra, Amritesh Ranjan; Kant, Surya; Singh, Arpita

    2018-01-01

    Spontaneous pneumothorax is a very common medical emergency. Patients are often treated without treating the underlying cause. Lymphangioleiomyomatosis (LAM) is a rare cystic lung disease. Until recently, diagnosis of LAM was a challenge with nearly 100% mortality in 10 years, but better understanding of the disease through research and better radiological techniques and newer drugs such as sirolimus has improved the survival in such patients. We are presenting a rare case of LAM presenting as a secondary spontaneous pneumothorax treated with sirolimus. PMID:29487252

  3. Intravascular ultrasound assessment of minimumlumen area and intimal hyperplasia in in-stent restenosis after drug-eluting or bare-metal stent implantation. The Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Vikman, Saila; Antonsen, Lisbeth

    2017-01-01

    presenting with a DES or bare-metal stent (BMS) in-stent restenosis. Methods: The ``Nordic Intravascular Ultrasound Study (NIVUS)'' study was conducted in Nordic and Baltic countries as a prospective multicenter registry. Two hundred nine patients (DES n = 121 and BMS n = 88) with instent restenosis were...

  4. The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Park Kyung

    2012-03-01

    Full Text Available Abstract Background Second-generation drug-eluting stents (DES have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES. In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI. A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES and antiplatelet regimen (TAT vs DDAT. The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734.

  5. Tuberous Sclerosis Complex in 29 Children: Clinical and Genetic Analysis and Facial Angiofibroma Responses to Topical Sirolimus.

    Science.gov (United States)

    Wang, Senfen; Liu, Yuanxiang; Wei, Jinghai; Zhang, Jian; Wang, Zhaoyang; Xu, Zigang

    2017-09-01

    Tuberous sclerosis complex (TSC) is a genetic disorder and facial angiofibromas are disfiguring facial lesions. The aim of this study was to analyze the clinical and genetic features of TSC and to assess the treatment of facial angiofibromas using topical sirolimus in Chinese children. Information was collected on 29 patients with TSC. Genetic analyses were performed in 12 children and their parents. Children were treated with 0.1% sirolimus ointment for 36 weeks. Clinical efficacy and plasma sirolimus concentrations were evaluated at baseline and 12, 24, and 36 weeks. Twenty-seven (93%) of the 29 patients had hypomelanotic macules and 15 (52%) had shagreen patch; 11 of the 12 (92%) who underwent genetic analysis had gene mutations in the TSC1 or TSC2 gene. Twenty-four children completed 36 weeks of treatment with topical sirolimus; facial angiofibromas were clinically undetectable in four (17%). The mean decrease in the Facial Angiofibroma Severity Index (FASI) score at 36 weeks was 47.6 ± 30.4%. There was no significant difference in the FASI score between weeks 24 and 36 (F = 1.00, p = 0.33). There was no detectable systemic absorption of sirolimus. Hypomelanotic macules are often the first sign of TSC. Genetic testing has a high detection rate in patients with a clinical diagnosis of TSC. Topical sirolimus appears to be both effective and well-tolerated as a treatment of facial angiofibromas in children with TSC. The response typically plateaus after 12 to 24 weeks of treatment. © 2017 Wiley Periodicals, Inc.

  6. Incidence and predictors of target lesion failure in a multiethnic Asian population receiving the SYNERGY coronary stent: A prospective all-comers registry.

    Science.gov (United States)

    Ananthakrishna, Rajiv; Kristanto, William; Liu, Li; Chan, Siew-Pang; Loh, Poay Huan; Tay, Edgar L; Chan, Koo Hui; Chan, Mark Y; Lee, Chi-Hang; Low, Adrian F; Tan, Huay Cheem; Loh, Joshua P

    2018-03-07

    To evaluate the target lesion failure (TLF) rate of the SYNERGY stent in all-comers, multiethnic Asian population. Currently, most drug eluting stents deliver anti-proliferative drugs from a durable polymer which is associated with a risk of late stent thrombosis. The novel everolimus-eluting, platinum chromium SYNERGY stent is coated with a bioabsorbable abluminal polymer that resolves within 4 months. This was a prospective, single center registry of consecutive patients treated with the SYNERGY stent between December 2012 and April 2015. The primary outcome was the incidence of TLF, defined as the combination of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization (TLR) at 1 year. A total of 807 patients received the SYNERGY stent during the study period. One-year clinical outcome data was available for 765 patients (94.8%) and were considered for statistical analysis. The mean age was 60.7 ± 10.8 years, and 83.4% were males. Patients with acute myocardial infarction consisted of 50.3% (ST-segment elevation myocardial infarction: 23.0%, Non-ST-segment elevation myocardial infarction: 27.3%) of the study population. The treated lesions were complex (ACC/AHA type B2/C: 72.7%). The primary end point of TLF at 1 year was 5.8%. Rates of cardiac mortality, target vessel myocardial infarction, and TLR were 4.2, 1.0, and 1.3%, respectively, at 1 year. Predictors of the incidence and time to early TLF were female gender, Malay ethnicity, diabetes mellitus, acute myocardial infarction at presentation, a prior history of coronary artery bypass surgery and the presence of lesion calcification. The incidence of definite stent thrombosis was 0.4% at 1 year. In this registry, the use of the SYNERGY stent was associated with low rates of TLF at 1 year. © 2018 Wiley Periodicals, Inc.

  7. Triple antithrombotic therapy in patients with atrial fibrillation undergoing coronary artery stenting: hovering among bleeding risk, thromboembolic events, and stent thrombosis

    Directory of Open Access Journals (Sweden)

    Menozzi Mila

    2012-10-01

    Full Text Available Abstract Dual antiplatelet treatment with aspirin and clopidogrel is the antithrombotic treatment recommended after an acute coronary syndrome and/or coronary artery stenting. The evidence for optimal antiplatelet therapy for patients, in whom long-term treatment oral anticoagulation is mandatory, is however scarce. To evaluate the safety and efficacy of the various antithrombotic strategies adopted in this population, we reviewed the available evidence on the management of patients receiving oral anticoagulation, such as a vitamin-k-antagonists, referred for coronary artery stenting. Atrial fibrillation is the most frequent indication for oral anticoagulation. The need of starting antiplatelet therapy in this clinical scenario raises concerns about the combination to choose: triple therapy with warfarin, aspirin, and a thienopyridine being the most frequent and advised. The safety of this regimen appeared suboptimal because of an increased risk in hemorrhagic complications. On the other hand, the combination of oral anticoagulation and an antiplatelet agent is suboptimal in preventing thromboembolic events and stent thrombosis; dual antiplatelet therapy may be considered only when a high hemorrhagic risk and low thromboembolic risk are perceived. Indeed, the need for prolonged multiple-drug antithrombotic therapy increases the bleeding risks when drug eluting stents are used. Since current evidence derives mainly from small, single-center and retrospective studies, large-scale prospective multicenter studies are urgently needed.

  8. Effects of physiotherapy combined with sirolimus in a patient with vascular malformation: A case report.

    Science.gov (United States)

    Akbayrak, Türkan; Orhan, Ceren; Baran, Emine; Kaya, Serap; Coskun, Gürsoy; Varan, Ali

    2016-01-01

    The aim of the present case report was to investigate the effects of a physiotherapy program combined with sirolimus in a child patient with upper extremity edema and joint limitation due to low-flow vascular malformation. This case report included an 11-year-old male patient (26 kg, 130 cm) diagnosed with congenital lymphovascular malformation on the left and right chest. The patient, who had edema on the upper left extremity and experienced joint limitations, was administered complete decongestive therapy (CDT) and manual therapy in combination with sirolimus. Physiotherapy included a total of 24 sessions, 3 sessions a week for 8 weeks. Following the physiotherapy, the patient was assigned to a home therapy program, and then the maintenance phase of the CDT was initiated. Evaluations were carried out at baseline, at the end of week 8, and after 12 months. Following the physiotherapy program combined with sirolimus, a decrease in extremity volume, an increase in joint movement range, and an improvement in disease-related complaints were observed. Physiotherapy methods combined with sirolimus may be an effective treatment method in patients with vascular malformations. However, further studies with larger sample size are warranted.

  9. EFFICACY AND SAFETY OF SIROLIMUS IN REDUCING CYST VOLUME IN PATIENTS WITH AUTOSOMAL DOMINANT POLYCYSTIC KIDNEY DISEASE

    Directory of Open Access Journals (Sweden)

    Sreelatha Melemadathil

    2016-11-01

    Full Text Available BACKGROUND Autosomal-Dominant Polycystic Kidney Disease is by far the most frequent inherited kidney disease. In White populations, its prevalence ranges from one in 400 to one in 1000 (Gabow 1993. Though the corresponding figure in Blacks is not yet available, the incidence of ESRD due to ADPKD is similar in American Blacks and Whites (Yium et al, 1994. Renoprotective interventions in ADPKD are maximal reduction of blood pressure and proteinuria and limit the effects of additional potential promoters of disease progression such as dyslipidaemia, chronic hyperglycaemia or smoking. At present, there is no definitive treatment for reducing cyst volume and hence disease progression. Sirolimus (Rapamycin is an immunosuppressant mostly used for the management of kidney transplant recipients. This drug by specifically and effectively inhibiting mTOR, exerts antiproliferative and growth inhibiting effects and could be important for the inhibition of cyst progression in ADPKD. MATERIALS AND METHODS It is an interventional randomised open label, active control study for six months. ADPKD type 1 patients between the age of 18 to 60 years with a GFR > 40 mL/min/1.73 m2 were included in the study. RESULTS Total number of subjects enrolled – 60. Patients enrolled in sirolimus arm – 40. Patients enrolled in conventional treatment arm - 20. Patients dropped out due to sirolimus side effects - 5. Patients lost to followup - 1. Patients completed treatment in conventional treatment arm - 20. CONCLUSION Treatment with mTOR inhibitor sirolimus for 6 months was effective in reducing total kidney volume, total renal cyst volume and volume of the largest cyst in patients with ADPKD. There was a small, but significant increase in renal parenchymal volume on treatment with sirolimus. Extending the duration of treatment to one year caused further significant reduction in total kidney volume and cyst volume. Major side effect of sirolimus in our patients was

  10. Systematic Review of Infrapopliteal Drug-Eluting Stents: A Meta-Analysis of Randomized Controlled Trials

    Energy Technology Data Exchange (ETDEWEB)

    Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [NHS Foundation Trust, King' s Health Partners, Department of Interventional Radiology, Guy' s and St. Thomas' Hospitals (United Kingdom); Spiliopoulos, Stavros [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece); Diamantopoulos, Athanasios [NHS Foundation Trust, King' s Health Partners, Department of Interventional Radiology, Guy' s and St. Thomas' Hospitals (United Kingdom); Karnabatidis, Dimitris [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece); Sabharwal, Tarun [NHS Foundation Trust, King' s Health Partners, Department of Interventional Radiology, Guy' s and St. Thomas' Hospitals (United Kingdom); Siablis, Dimitris [Patras University Hospital, Department of Interventional Radiology, School of Medicine (Greece)

    2013-06-15

    IntroductionDrug-eluting stents (DES) have been proposed for the treatment of infrapopliteal arterial disease. We performed a systematic review to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing infrapopliteal DES.Materials and MethodsPubMed (Medline), EMBASE (Excerpta Medical Database), AMED (Allied and Complementary medicine Database), Scopus, CENTRAL (Cochrane Central Register of Controlled Trials), online content, and abstract meetings were searched in September 2012 for eligible RCTs according to the preferred reporting items for systematic reviews and meta-analyses selection process. Risk of bias was assessed using the Cochrane Collaboration's tool. Primary endpoint was primary patency defined as absence of {>=}50 % vessel restenosis at 1 year. Secondary outcome measures included patient survival, limb amputations, change of Rutherford-Becker class, target lesion revascularization (TLR) events, complete wound healing, and event-free survival at 1 year. Risk ratio (RRs) were calculated using the Mantel-Haenszel fixed effects model, and number-needed-to-treat values are reported.ResultsThree RCTs involving 501 patients with focal infrapopliteal lesions were analyzed (YUKON-BTX, DESTINY, and ACHILLES trials). All three RCTs included relatively short and focal infrapopliteal lesions. At 1 year, there was clear superiority of infrapopliteal DES compared with control treatments in terms of significantly higher primary patency (80.0 vs. 58.5 %; pooled RR = 1.37, 95 % confidence interval [CI] = 1.18-1.58, p < 0.0001; number-needed-to-treat (NNT) value = 4.8), improvement of Rutherford-Becker class (79.0 vs. 69.6 %; pooled RR = 1.13, 95 % CI = 1.002-1.275, p = 0.045; NNT = 11.1), decreased TLR events (9.9 vs. 22.0 %; pooled RR = 0.45, 95 % CI = 0.28-0.73, p = 0.001; NNT = 8.3), improved wound healing (76.8 vs. 59.7 %; pooled RR = 1.29, 95 % CI = 1.02-1.62, p = 0.04; NNT = 5.9), and better overall

  11. Systematic Review of Infrapopliteal Drug-Eluting Stents: A Meta-Analysis of Randomized Controlled Trials

    International Nuclear Information System (INIS)

    Katsanos, Konstantinos; Spiliopoulos, Stavros; Diamantopoulos, Athanasios; Karnabatidis, Dimitris; Sabharwal, Tarun; Siablis, Dimitris

    2013-01-01

    IntroductionDrug-eluting stents (DES) have been proposed for the treatment of infrapopliteal arterial disease. We performed a systematic review to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing infrapopliteal DES.Materials and MethodsPubMed (Medline), EMBASE (Excerpta Medical Database), AMED (Allied and Complementary medicine Database), Scopus, CENTRAL (Cochrane Central Register of Controlled Trials), online content, and abstract meetings were searched in September 2012 for eligible RCTs according to the preferred reporting items for systematic reviews and meta-analyses selection process. Risk of bias was assessed using the Cochrane Collaboration’s tool. Primary endpoint was primary patency defined as absence of ≥50 % vessel restenosis at 1 year. Secondary outcome measures included patient survival, limb amputations, change of Rutherford–Becker class, target lesion revascularization (TLR) events, complete wound healing, and event-free survival at 1 year. Risk ratio (RRs) were calculated using the Mantel–Haenszel fixed effects model, and number-needed-to-treat values are reported.ResultsThree RCTs involving 501 patients with focal infrapopliteal lesions were analyzed (YUKON-BTX, DESTINY, and ACHILLES trials). All three RCTs included relatively short and focal infrapopliteal lesions. At 1 year, there was clear superiority of infrapopliteal DES compared with control treatments in terms of significantly higher primary patency (80.0 vs. 58.5 %; pooled RR = 1.37, 95 % confidence interval [CI] = 1.18–1.58, p < 0.0001; number-needed-to-treat (NNT) value = 4.8), improvement of Rutherford–Becker class (79.0 vs. 69.6 %; pooled RR = 1.13, 95 % CI = 1.002–1.275, p = 0.045; NNT = 11.1), decreased TLR events (9.9 vs. 22.0 %; pooled RR = 0.45, 95 % CI = 0.28–0.73, p = 0.001; NNT = 8.3), improved wound healing (76.8 vs. 59.7 %; pooled RR = 1.29, 95 % CI = 1.02–1.62, p = 0.04; NNT = 5.9), and better

  12. Sirolimus as an alternative to anticalcineurin therapy in heart transplantation: experience of a single center.

    Science.gov (United States)

    Fernandez-Valls, M; Gonzalez-Vilchez, F; de Prada, J A Vazquez; Ruano, J; Ruisanchez, C; Martin-Duran, R

    2005-11-01

    We report a series of 26 heart transplant recipients with renal impairment in which sirolimus was used as the basic immunosuppresive drug (without associated calcineurin inhibitors) to avoid further nephrotoxicity. Sirolimus (trough levels 10 to 12 ng/mL, average daily dose 3 mg) was used in two settings: de novo in 7 patients with significant preexistent renal impairment and as a chronic conversion in 19 stable patients with established renal failure (creatinine level >2 mg/dL). In all de novo patients (n = 7), the renal function significantly improved. Creatinine fell from 2.95 +/- 0.9 mg/dL to 1.41 +/- 0.4 mg/dL at follow-up (P = .0017). One patient died suddenly of a massive pulmonary embolism. Only one patient experienced histologic but reversible rejection. In one patient, anemia and diarrhea prompted sirolimus withdrawal. Five patients had infectious episodes: three bacterial pneumonias, one mediastinitis, and two CMV infections. In the chronic conversion group (n = 19), the improvement was mostly limited to patients with moderate renal failure (creatinine < or =2.5 mg/dL) in which creatinine fell from 2.24 +/- 0.2 to 1.9 +/- 0.27 mg/dL, P = .009). When basal creatinine was over 2.5 mg/dL, only one third of the patients improved after conversion. Two patients died: terminal renal failure and cerebrovascular accident. There were no clinical episodes of rejection. Secondary effects prompted the discontinuation of sirolimus in five patients: two definite and one possible interstitial pneumonitis and two cases of anemia). The symptoms resolved after sirolimus withdrawal. Six patients had infection: four pneumonias, one sepsis, and one cutaneous abscess. Sirolimus is an interesting alternative to calcineurin inhibitors in selected patients with renal impairment. It prevents renal failure in de novo recipients at high risk of catastrophic renal damage and ameliorates renal dysfunction in chronic patients with moderate renal dysfunction. Given the high incidence of

  13. Luminal flow amplifies stent-based drug deposition in arterial bifurcations.

    Directory of Open Access Journals (Sweden)

    Vijaya B Kolachalama

    2009-12-01

    Full Text Available Treatment of arterial bifurcation lesions using drug-eluting stents (DES is now common clinical practice and yet the mechanisms governing drug distribution in these complex morphologies are incompletely understood. It is still not evident how to efficiently determine the efficacy of local drug delivery and quantify zones of excessive drug that are harbingers of vascular toxicity and thrombosis, and areas of depletion that are associated with tissue overgrowth and luminal re-narrowing.We constructed two-phase computational models of stent-deployed arterial bifurcations simulating blood flow and drug transport to investigate the factors modulating drug distribution when the main-branch (MB was treated using a DES. Simulations predicted extensive flow-mediated drug delivery in bifurcated vascular beds where the drug distribution patterns are heterogeneous and sensitive to relative stent position and luminal flow. A single DES in the MB coupled with large retrograde luminal flow on the lateral wall of the side-branch (SB can provide drug deposition on the SB lumen-wall interface, except when the MB stent is downstream of the SB flow divider. In an even more dramatic fashion, the presence of the SB affects drug distribution in the stented MB. Here fluid mechanic effects play an even greater role than in the SB especially when the DES is across and downstream to the flow divider and in a manner dependent upon the Reynolds number.The flow effects on drug deposition and subsequent uptake from endovascular DES are amplified in bifurcation lesions. When only one branch is stented, a complex interplay occurs - drug deposition in the stented MB is altered by the flow divider imposed by the SB and in the SB by the presence of a DES in the MB. The use of DES in arterial bifurcations requires a complex calculus that balances vascular and stent geometry as well as luminal flow.

  14. Sensor to detect endothelialization on an active coronary stent

    Directory of Open Access Journals (Sweden)

    Coffey Arthur C

    2010-11-01

    Full Text Available Abstract Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks.

  15. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  16. Effect of cyclosporine, tacrolimus and sirolimus on cellular senescence in renal epithelial cells.

    Science.gov (United States)

    Koppelstaetter, Christian; Kern, Georg; Leierer, Gisela; Mair, Sabine Maria; Mayer, Gert; Leierer, Johannes

    2018-04-01

    In transplantation medicine calcineurin inhibitors (CNI) still represent the backbone of immunosuppressive therapy. The nephrotoxic potential of the CNI Cyclosporine A (CsA) and Tacrolimus (FK506) is well recognized and CNI not only have been linked with toxicity, but also with cellular senescence which hinders parenchymal tissue regeneration and thus may prime kidneys for subsequent insults. To minimize pathological effects on kidney grafts, alternative immunosuppressive agents like mTOR inhibitors or the T-cell co-stimulation blocker Belatacept have been introduced. We compared the effects of CsA, FK506 and Sirolimus on the process of cellular senescence in different human renal tubule cell types (HK2, RPTEC). Telomere length (by real time PCR), DNA synthesis (by BrdU incorporation), cell viability (by Resazurin conversion), gene expression (by RT-PCR), protein (by western blotting), Immuncytochemistry and H 2 O 2 production (by Amplex Red® conversion) were evaluated. DNA synthesis was significantly reduced when cells were treated with cyclosporine but not with tacrolimus and sirolimus. Resazurin conversion was not altered by all three immunosuppressive agents. The gene expression as well as protein production of the cell cycle inhibitor p21 (CDKN1A) but not p16 (CDKN2A) was significantly induced by cyclosporine compared to the other two immunosuppressive agents when determined by western blotting an immuncytochemistry. Relative telomere length was reduced and hydrogen peroxide production increased after treatment with CsA but not with FK506 or sirolimus. In summary, renal tubule cells exposed to CsA show clear signs of cellular senescence where on the contrary the second calcineurin inhibitor FK506 and the mTOR inhibitor sirolimus are not involved in such mechanisms. Chronic renal allograft dysfunction could be in part triggered by cellular senescence induced by immunosuppressive medication and the choice of drug could therefore influence long term outcome

  17. Desfechos clínicos por região geográfica em pacientes com implante de stent eluidor de Zotarolimus Desenlaces clínicos por región geográfica en pacientes con implante de Stent liberador de Zotarolimus Clinical outcomes by geographic region for patients implanted with the zotarolimus-eluting stent

    Directory of Open Access Journals (Sweden)

    Chaim Lotan

    2011-05-01

    ón geográfica sobre los desenlaces clínicos con el stent liberador de zotarolimus se evaluó en tres regiones: Pacífico Asiático, Europa y América Latina. MÉTODOS: A total of 8,314 patients (6.572 Europe, 1.522 Asia Pacific, and 220 Latin America were followed for 1 year; 2.116 of these (1.613, 316, and 187, respectively were followed for 2 years. Patient and lesion characteristics, dual antiplatelet therapy, and clinical outcomes were compared between Latin America and the other regions. RESULTADOS: Los pacientes en América Latina tuvieron la mayor proporción de factores de riesgo e infarto de miocardio previo. Hubo un rápido descenso en el uso de la terapia antiplaquetaria en América Latina, el 44,9% en 6 meses para 22,5% en 1 año y 7,8% en 2 años (Europa: un 87,4%, un 61,5%, un 19,7%; Pacífico Asiático: un 82,4%, un 67,0%, un 45,7%, respectivamente. No hubo diferencias significativas entre América Latina y Europa o Pacífico Asiático para cualquier desenlace en cualquier momento. La incidencia de trombosis de stent probable y definitiva por el Academic Research Consortium fue baja (BACKGROUND: Differences between geographic regions in patient characteristics and outcomes, particularly for acute coronary syndromes, have been demonstrated in clinical trials. Clinical outcomes after percutaneous coronary interventions with the Zotarolimus-eluting stent in a real-world population were assessed over time. OBJECTIVE: The influence of geographic location on clinical outcomes with the Zotarolimus-eluting stent was assessed in 3 regions: Asia Pacific, Europe, and Latin America. METHODS: A total of 8,314 patients (6,572 Europe, 1,522 Asia Pacific, and 220 Latin America were followed for 1 year; 2,116 of these (1,613, 316, and 187, respectively were followed for 2 years. Patient and lesion characteristics, dual antiplatelet therapy, and clinical outcomes were compared between Latin America and the other regions. RESULTS: Patients in Latin America had the highest

  18. Clinical effects of sirolimus treatment in patients with increased ...

    African Journals Online (AJOL)

    transplanted kidney function will be lost. However, the development of new immunosuppressors, such as sirolimus (SRL), make it possible to stop CNI treatment [6]. Treating renal transplant patients with immunosuppressive drugs other than CNIs has received more attention in recent years. SRL, a new generation of ...

  19. Impact of Chronic Renal Failure on Safety and Effectiveness of Paclitaxel-Eluting Stents for Femoropopliteal Artery Disease: Subgroup Analysis from Zilver PTX Post-Market Surveillance Study in Japan.

    Science.gov (United States)

    Ogawa, Yukihisa; Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Saunders, Alan T; Dake, Michael D

    2017-11-01

    Favorable long-term outcomes of the Zilver PTX drug-eluting stent (DES) in femoropopliteal lesions have been demonstrated. Chronic renal failure (CRF) has been shown to be a risk factor for restenosis and decreased limb salvage. The results of the DES in patients with CRF have not previously been reported. This study compares the results with the DES in patients with CRF and those without CRF. This retrospective analysis from the Zilver PTX Japan Post-Market Surveillance Study included 321 patients with CRF and 584 patients without CRF. Outcomes included freedom from target lesion revascularization (TLR) and patency. Of the patients included in this subgroup analysis, 2-year data were available for 209 patients in the CRF group and 453 patients in the non-CRF group. The two groups were similar in terms of lesion length and the frequency of in-stent restenosis. Critical limb ischemia, severe calcification, and diabetes were more common in patients with CRF, whereas total occlusion was more common in patients without CRF. Freedom from TLR rates were 81.4 versus 84.9% (p = 0.24), and patency rates were 70.7 versus 70.3% (p = 0.95) in patients with and without CRF at 2 years, respectively. This is the first comparative study of the DES in femoropopliteal artery lesions in patients with and without CRF. These results indicate that the DES placed in femoropopliteal artery lesions of CRF patients is safe and effective with similar patency and TLR rates to patients without CRF. Level 3, Post-Market Surveillance Study.

  20. Computational Bench Testing to Evaluate the Short-Term Mechanical Performance of a Polymeric Stent.

    Science.gov (United States)

    Bobel, A C; Petisco, S; Sarasua, J R; Wang, W; McHugh, P E

    2015-12-01

    Over the last decade, there has been a significant volume of research focussed on the utilization of biodegradable polymers such as poly-L-lactide-acid (PLLA) for applications associated with cardiovascular disease. More specifically, there has been an emphasis on upgrading current clinical shortfalls experienced with conventional bare metal stents and drug eluting stents. One such approach, the adaption of fully formed polymeric stents has led to a small number of products being commercialized. Unfortunately, these products are still in their market infancy, meaning there is a clear non-occurrence of long term data which can support their mechanical performance in vivo. Moreover, the load carry capacity and other mechanical properties essential to a fully optimized polymeric stent are difficult, timely and costly to establish. With the aim of compiling rapid and representative performance data for specific stent geometries, materials and designs, in addition to reducing experimental timeframes, Computational bench testing via finite element analysis (FEA) offers itself as a very powerful tool. On this basis, the research presented in this paper is concentrated on the finite element simulation of the mechanical performance of PLLA, which is a fully biodegradable polymer, in the stent application, using a non-linear viscous material model. Three physical stent geometries, typically used for fully polymeric stents, are selected, and a comparative study is performed in relation to their short-term mechanical performance, with the aid of experimental data. From the simulated output results, an informed understanding can be established in relation to radial strength, flexibility and longitudinal resistance, that can be compared with conventional permanent metal stent functionality, and the results show that it is indeed possible to generate a PLLA stent with comparable and sufficient mechanical performance. The paper also demonstrates the attractiveness of FEA as a tool

  1. Randomized comparison of final kissing balloon dilatation versus no final kissing balloon dilatation in patients with coronary bifurcation lesions treated with main vessel stenting: the Nordic-Baltic Bifurcation Study III

    DEFF Research Database (Denmark)

    Niemelä, Matti; Kervinen, Kari; Erglis, Andrejs

    2011-01-01

    BACKGROUND: It is unknown whether the preferred 1-stent bifurcation stenting approach with stenting of the main vessel (MV) and optional side branch stenting using drug-eluting stents should be finalized by a kissing balloon dilatation (FKBD). Therefore, we compared strategies of MV stenting......, or stent thrombosis within 6 months. The 6-month major adverse cardiac event rates were 2.1% and 2.5% (P=1.00) in the FKBD and no-FKBD groups, respectively. Procedure and fluoroscopy times were longer and more contrast media was needed in the FKBD group than in the no-FKBD group. Three hundred twenty...... angiographic side branch (re)stenosis, especially in patients with true bifurcation lesions. The simple no-FKBD procedures resulted in reduced use of contrast media and shorter procedure and fluoroscopy times. Long-term data on stent thrombosis are needed....

  2. OCT guidance during stent implantation in primary PCI: A randomized multicenter study with nine months of optical coherence tomography follow-up

    Czech Academy of Sciences Publication Activity Database

    Kala, P.; Červinka, P.; Jakl, M.; Kanovský, J.; Kupec, A.; Špaček, R.; Kvasnak, M.; Poloczek, M.; Červinková, M.; Bezerra, H.; Valenta, Zdeněk; Attizzani, G.; Schnell, A.; Hong, L.; Costa, M.

    2018-01-01

    Roč. 250, 1 January (2018), s. 98-103 ISSN 0167-5273 Institutional support: RVO:67985807 Keywords : optical coherence tomography * OCT * primary PCI * ST-segment elevation myocardial infarction * drug-eluting stents Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 6.189, year: 2016

  3. Bioresorbable Polymer Coated Metallic Stents and Fully Bioresorbable Scaffolds: Benefits and limitations in different coronary lesion subsets, -clinical and intracascular imaging results-

    NARCIS (Netherlands)

    J.M. Fam (Jiang Ming)

    2018-01-01

    markdownabstractPercutaneous coronary intervention (PCI) which involves the deployment of devices such as metallic drug eluting stents (DES) in coronary artery lesions and concomitant dual antiplatelet therapy (DAPT) is one of the mainstays of management of coronary artery disease and has become one

  4. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    International Nuclear Information System (INIS)

    Veres, M.; Beiler, B.; Himics, L.; Tóth, S.; Koós, M.

    2010-01-01

    Many areas of modern medicine are almost unimaginable without the use of different kinds of implants. They used as replacements, supports, auxiliary devices etc. for various parts or functions of the body. Their use has many advantages, however there could be some drawbacks too, like the possibility of rejection, inflammation and other side-effects. Many of these drawbacks are directly related to the materials used for the implant fabrication. Coatings are widely used to eliminate the unwanted effects appearing after the implantation. In addition to the protection and separation of tissues from the implant material they could also enhance the functionality and the acceptance of the artificial device and also promote the regeneration of the tissues after the intervention. Drug-eluting coatings are a good example for the latter. By delivery and controlled elution of drugs they could actively suppress inflammatory reactions, allergy and rejection of the implant, and their activity is localized to the place where these effects could mainly occur – to the region of the implant. This project is aimed to develop a drug-eluting porous polymer coating by radiation induced polymerization that can be used in different medical implants. The primary objects for this research are coronary stents however these porous layers could have perspective in other types of medical devices too. The main objectives are to develop a method for coating the surface of medical grade metallic alloy wires, plates and tubes with a porous polymer nanocomposite layer prepared by radiation induced polymerization and to characterize the obtained coatings

  5. Porous Polymer Drug-Eluting Coating Prepared by Radiation Induced Polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Veres, M.; Beiler, B.; Himics, L.; Tóth, S.; Koós, M., E-mail: vm@szfki.hu [Hungarian Academy of Sciences, Research Institute for Solid State Physics and Optics, Department of Laser Applications, Konkoly Thege Miklós ut 29-33, 1121 Budapest, P.O. Box 49, 1525 Budapest (Hungary)

    2010-07-01

    Many areas of modern medicine are almost unimaginable without the use of different kinds of implants. They used as replacements, supports, auxiliary devices etc. for various parts or functions of the body. Their use has many advantages, however there could be some drawbacks too, like the possibility of rejection, inflammation and other side-effects. Many of these drawbacks are directly related to the materials used for the implant fabrication. Coatings are widely used to eliminate the unwanted effects appearing after the implantation. In addition to the protection and separation of tissues from the implant material they could also enhance the functionality and the acceptance of the artificial device and also promote the regeneration of the tissues after the intervention. Drug-eluting coatings are a good example for the latter. By delivery and controlled elution of drugs they could actively suppress inflammatory reactions, allergy and rejection of the implant, and their activity is localized to the place where these effects could mainly occur – to the region of the implant. This project is aimed to develop a drug-eluting porous polymer coating by radiation induced polymerization that can be used in different medical implants. The primary objects for this research are coronary stents however these porous layers could have perspective in other types of medical devices too. The main objectives are to develop a method for coating the surface of medical grade metallic alloy wires, plates and tubes with a porous polymer nanocomposite layer prepared by radiation induced polymerization and to characterize the obtained coatings.

  6. The mTOR inhibitor sirolimus suppresses renal, hepatic, and cardiac tissue cellular respiration.

    Science.gov (United States)

    Albawardi, Alia; Almarzooqi, Saeeda; Saraswathiamma, Dhanya; Abdul-Kader, Hidaya Mohammed; Souid, Abdul-Kader; Alfazari, Ali S

    2015-01-01

    The purpose of this in vitro study was to develop a useful biomarker (e.g., cellular respiration, or mitochondrial O2 consumption) for measuring activities of mTOR inhibitors. It measured the effects of commonly used immunosuppressants (sirolimus-rapamycin, tacrolimus, and cyclosporine) on cellular respiration in target tissues (kidney, liver, and heart) from C57BL/6 mice. The mammalian target of rapamycin (mTOR), a serine/ threonine kinase that supports nutrient-dependent cell growth and survival, is known to control energy conversion processes within the mitochondria. Consistently, inhibitors of mTOR (e.g., rapamycin, also known as sirolimus or Rapamune®) have been shown to impair mitochondrial function. Inhibitors of the calcium-dependent serine/threonine phosphatase calcineurin (e.g., tacrolimus and cyclosporine), on the other hand, strictly prevent lymphokine production leading to a reduced T-cell function. Sirolimus (10 μM) inhibited renal (22%, P=0.002), hepatic (39%, Prespiration. Tacrolimus and cyclosporine had no or minimum effects on cellular respiration in these tissues. Thus, these results clearly demonstrate that impaired cellular respiration (bioenergetics) is a sensitive biomarker of the immunosuppressants that target mTOR.

  7. Treatment with sirolimus results in complete responses in patients with autoimmune lymphoproliferative syndrome

    Science.gov (United States)

    Teachey, David T.; Greiner, Robert; Seif, Alix; Attiyeh, Edward; Bleesing, Jack; Choi, John; Manno, Catherine; Rappaport, Eric; Schwabe, Dirk; Sheen, Cecilia; Sullivan, Kathleen E.; Zhuang, Hongming; Wechsler, Daniel S.; Grupp, Stephan A.

    2010-01-01

    Summary We hypothesized that sirolimus, an mTOR inhibitor, may be effective in patients with autoimmune lymphoproliferative syndrome (ALPS) and treated patients who were intolerant to or failed other therapies. Four patients were treated for autoimmune cytopenias; all had a rapid complete or near complete response. Two patients were treated for autoimmune arthritis and colitis, demonstrating marked improvement. Three patients had complete resolution of lymphadenopathy and splenomegaly and all patients had a reduction in double negative T cells, a population hallmark of the disease. Based on these significant responses, we recommend that sirolimus be considered as second-line therapy for patients with steroid-refractory disease. PMID:19208097

  8. Impact of Clinical Presentation (Stable Angina Pectoris vs Unstable Angina Pectoris or Non-ST-Elevation Myocardial Infarction vs ST-Elevation Myocardial Infarction) on Long-Term Outcomes in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents

    DEFF Research Database (Denmark)

    Giustino, Gennaro; Baber, Usman; Stefanini, Giulio Giuseppe

    2015-01-01

    The long-term risk associated with different coronary artery disease (CAD) presentations in women undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is poorly characterized. We pooled patient-level data for women enrolled in 26 randomized clinical trials. Of 11......,577 women included in the pooled database, 10,133 with known clinical presentation received a DES. Of them, 5,760 (57%) had stable angina pectoris (SAP), 3,594 (35%) had unstable angina pectoris (UAP) or non-ST-segment-elevation myocardial infarction (NSTEMI), and 779 (8%) had ST......-segment-elevation myocardial infarction (STEMI) as clinical presentation. A stepwise increase in 3-year crude cumulative mortality was observed in the transition from SAP to STEMI (4.9% vs 6.1% vs 9.4%; p clinical...

  9. Optimization of cardiovascular stent against restenosis: factorial design-based statistical analysis of polymer coating conditions.

    Directory of Open Access Journals (Sweden)

    Gayathri Acharya

    Full Text Available The objective of this study was to optimize the physicodynamic conditions of polymeric system as a coating substrate for drug eluting stents against restenosis. As Nitric Oxide (NO has multifunctional activities, such as regulating blood flow and pressure, and influencing thrombus formation, a continuous and spatiotemporal delivery of NO loaded in the polymer based nanoparticles could be a viable option to reduce and prevent restenosis. To identify the most suitable carrier for S-Nitrosoglutathione (GSNO, a NO prodrug, stents were coated with various polymers, such as poly (lactic-co-glycolic acid (PLGA, polyethylene glycol (PEG and polycaprolactone (PCL, using solvent evaporation technique. Full factorial design was used to evaluate the effects of the formulation variables in polymer-based stent coatings on the GSNO release rate and weight loss rate. The least square regression model was used for data analysis in the optimization process. The polymer-coated stents were further assessed with Differential scanning calorimetry (DSC, Fourier transform infrared spectroscopy analysis (FTIR, Scanning electron microscopy (SEM images and platelet adhesion studies. Stents coated with PCL matrix displayed more sustained and controlled drug release profiles than those coated with PLGA and PEG. Stents coated with PCL matrix showed the least platelet adhesion rate. Subsequently, stents coated with PCL matrix were subjected to the further optimization processes for improvement of surface morphology and enhancement of the drug release duration. The results of this study demonstrated that PCL matrix containing GSNO is a promising system for stent surface coating against restenosis.

  10. Effect of cytochrome P450 2C19 polymorphism on adverse cardiovascular events after drug-eluting stent implantation in a large Hakka population with acute coronary syndrome receiving clopidogrel in southern China.

    Science.gov (United States)

    Zhong, Zhixiong; Hou, Jingyuan; Zhang, Qifeng; Li, Bin; Li, Cunren; Liu, Zhidong; Yang, Min; Zhong, Wei; He, Xuebo; Wu, Hesen; Zhong, Miaocai; Zhao, Pingsen

    2018-04-01

    The objective of this study is to evaluate the effects of cytochrome P450 2C19 (CYP2C19) polymorphism on adverse cardiovascular events (MACE) in Hakka patients with acute coronary syndrome (ACS) receiving clopidogrel who had undergone coronary drug-eluting stent placement after percutaneous coronary intervention (PCI) in southern China. Genotyping of CYP2C19 and MACE of 934 ACS patients with PCI on clopidogrel maintenance therapy were analyzed. Patients who carried loss-of-function CYP2C19 were treated with a 150-mg maintenance dose of clopidogrel or 90 mg of ticagrelor antiplatelet therapy, and patients who were non-carriers received clopidogrel therapy daily at a maintenance dose of 75 mg and the patients were followed-up for at least 12 months. The primary efficacy endpoint was a composite of cardiovascular death, myocardial infarction, and target vessel revascularization and stroke. The allelic frequency of CYP2C19*2 and CYP2C19*3 of Hakka patients in the current study was 31.64 and 5.19%, respectively. The CYP2C19 wild-type homozygotes (*1/*1) were the most predominant among the patients (40.36%), followed by the CYP2C19*2 heterozygotes (*1/*2) (40.26%). The distribution of CYP2C19 phenotypes was divided into extensive metabolizers (EM; 40.36%), intermediate metabolizers (IM; 45.61%), and poor metabolizers (PM; 14.03%). Based on the genotype-guided antiplatelet therapy, there was no significant association between the carrier status and the clinical outcome at 1, 6, and 12 months. In addition, no significant difference in the rates of bleeding was found among the three groups. After logistic regression analysis, hypertension was the only independent predictor of cardiovascular events (relative risk, 1.501; 95% CI, 1.011 to 2.229; P = 0.044). Our results shed new light on the important benefit of testing CYP2C19 polymorphisms before prescribing clopidogrel in patients treated with drug-eluting stent implantation after PCI. The testing may help to

  11. Heparin monotherapy or bivalirudin during percutaneous coronary intervention in patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease: results from the Evaluation of Drug-Eluting Stents and Ischemic Events registry.

    Science.gov (United States)

    Bangalore, Sripal; Pencina, Michael J; Kleiman, Neal S; Cohen, David J

    2014-06-01

    The use of bivalirudin versus unfractionated heparin monotherapy in patients without ST-segment-elevation myocardial infarction is not well defined. The study population consisted of patients enrolled in the Evaluation of Drug-Eluting Stents and Ischemic Events (EVENT) registry with either non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease, who underwent percutaneous coronary intervention with either unfractionated heparin or bivalirudin monotherapy. Propensity score matching was used to adjust for baseline characteristics. The primary bleeding (in-hospital composite bleeding-access site bleeding, thrombolysis in myocardial infarction major/minor bleeding, or transfusion) and primary (in-hospital death/myocardial infarction) and secondary ischemic outcomes (death/myocardial infarction/unplanned repeat revascularization at 12 months) were evaluated. Propensity score matching yielded 1036 patients with non-ST-segment-elevation acute coronary syndromes and 2062 patients with stable ischemic heart disease. For the non-ST-segment-elevation acute coronary syndrome cohort, bivalirudin use was associated with lower bleeding (difference, -3.3% [-0.8% to -5.8%]; P=0.01; number need to treat=30) without increase in either primary (difference, 1.2% [4.1% to -1.8%]; P=0.45) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [1.3% to -1.3%]; P=1.00). Similarly, in the stable ischemic heart disease cohort, bivalirudin use was associated with lower bleeding (difference, -1.8% [-0.4% to -3.3%]; P=0.01; number need to treat=53) without increase in either primary (difference, 0.4% [2.3% to -1.5%]; P=0.70) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [0.7% to -0.7%]; P=1.00) when compared with unfractionated heparin monotherapy. Among patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease undergoing percutaneous coronary intervention, bivalirudin use

  12. No major neurologic complications with sirolimus use in heart transplant recipients

    NARCIS (Netherlands)

    van de Beek, Diederik; Kremers, Walter K.; Kushwaha, Sudhir S.; McGregor, Christopher G. A.; Wijdicks, Eelco F. M.

    2009-01-01

    OBJECTIVE: To determine whether sirolimus therapy is associated with neurologic complications, including stroke, among heart transplant recipients. PATIENTS AND METHODS: We retrospectively studied patients who underwent heart transplant at Mayo Clinic's site in Rochester, MN, from January 1, 1988,

  13. Re-examining minimal luminal diameter relocation and quantitative coronary angiography - Intravascular ultrasound correlations in stented saphenous vein grafts: Methodological insights from the randomised RRISC trial

    NARCIS (Netherlands)

    O. Semeraro (Oscar); P. Agostoni (Pierfrancesco); S. Verheye (Stefan); G.J.J. van Langenhove (Glenn); P.A. van den Heuvel (Paul); C. Convens (Carl); F. van den Branden (Frank); N. Bruining (Nico); P. Vermeersch (Paul)

    2009-01-01

    textabstractAims: Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. Methods and results: Using quantitative coronary angiography (QCA)

  14. Sex differences in the outcomes of stent implantation in mini-swine model.

    Science.gov (United States)

    Kunio, Mie; Wong, Gee; Markham, Peter M; Edelman, Elazer R

    2018-01-01

    Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.

  15. Sirolimus alternative to blood transfusion as a life saver in blue rubber bleb nevus syndrome: A case report.

    Science.gov (United States)

    Wang, Ke-Ling; Ma, Shu-Fang; Pang, Ling-Yu; Zhang, Meng-Na; Hu, Lin-Yan; Liu, Meng-Jia; Zou, Li-Ping

    2018-02-01

    Blue rubber bleb nevus syndrome (BRBNS) is a rare disease characterized by multiple venous malformations. The gastrointestinal bleeding and secondary iron deficiency anemia are the most common complications. There are currently no effective treatments for BRBNS. Here, we report a case of successful treatment with a small dose of sirolimus of a BRBN patient with a de novo gene mutation. A 12-year-old female was admitted to our hospital with multiple hemangiomas for 12 years. The patient often displayed melena; she recently received transfusion of 2 units of red blood cells once every 2 weeks. Multiple fist-sized hemangiomas were piled up on both sides and back of the neck, and were also noted on the arms, legs, chest, back, and on the tip of the tongue. The laboratory findings demonstrated severe anemia. Blood sample sequencing detected a heterozygous de novo mutation c.2545C > Tin the TEK gene. Based on these findings, final diagnosis of Blue rubber bleb nevus syndrome (BRBNS) was made. After the diagnosis, low-dose sirolimus was orally administered. The patient's hemoglobin was increased after treatment with sirolimus for 1 month. Since the initial treatment with sirolimus, she had not received any blood transfusions. The skin and mucosal hemangioma decreased significantly, and new digestive tract hemorrhage, muscle hematoma, or adverse drug reactions were not observed. we report a case of a mutation in exon 15 of the TEK gene leading to BRBN. It was successfully treated with a small dose of sirolimus as an alternative to blood transfusion in order to save the of BRBN patient's life.

  16. Analysis of trends and prospects regarding stents for human blood vessels.

    Science.gov (United States)

    Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo

    2018-01-01

    The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used

  17. Incidence, predicting factors, and clinical outcomes of periprocedural myocardial infarction after percutaneous coronary intervention for chronic total occlusion in the era of new-generation drug-eluting stents.

    Science.gov (United States)

    Kim, Jin-Ho; Kim, Byeong-Keuk; Kim, Seunghwan; Ahn, Chul-Min; Kim, Jung-Sun; Ko, Young-Guk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo

    2017-12-20

    This study aimed to examine predictors and clinical outcomes of periprocedural myocardial infarction (PMI) after chronic total occlusion (CTO) intervention. There are limited data on the clinical implications of PMI after CTO intervention in the new-generation drug-eluting stent (DES) era. We enrolled 337 patients who underwent CTO intervention and met the study criteria. We evaluated the incidence and predictors of PMI, defined as an increase in creatine kinase-MB ≥3× the upper limit of normal (ULN) after intervention and compared the occurrence rates of major adverse cardiac and cerebrovascular events (MACCE, defined as the composite of cardiac death, myocardial infarction, stent thrombosis, target-vessel revascularization, or cerebrovascular accidents) between the PMI and non-PMI groups. PMI occurred in 23 (6.8%) patients after CTO intervention. Significant independent predictors were previous bypass surgery [odds ratio (OR) = 5.52, 95% confidence interval (CI) = 1.17-25.92; P = 0.03], Japan-CTO score ≥3 (OR = 7.06, 95%CI = 2.57-19.39; P PMI group had a significantly higher MACCE rate than the non-PMI group (23.7 vs. 5.6%, P = 0.008 by log-rank test). PMI was an independent predictor of MACCE (HR = 4.26, 95%CI = 1.35-13.43; P = 0.01). The MACCE rate gradually increased in a CK-MB-dependent fashion and was highest in patients with ≥10× ULN (P = 0.005). Previous bypass surgery, high Japan-CTO score, side branch occlusion, and longer procedure time were strongly related to PMI occurrence after CTO intervention. PMI was significantly associated with worse clinical outcomes in the new-generation DES era. © 2017 Wiley Periodicals, Inc.

  18. Bioresorbable vascular scaffold (BVS) for in-stent chronic total occlusion: Antegrade recanalization and IVUS-guided BVS implantation by radial access

    Energy Technology Data Exchange (ETDEWEB)

    Medda, Massimo [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Casilli, Francesco, E-mail: frcasill@tin.it [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Bande, Marta [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Latini, Maria Giulia [Cardiologia Interventistica, IRCCS Policlinico San Donato, San Donato Milanese, Milano (Italy); Ghommidh, Mehdi [Interventional Cardiology Unit, Istituto Clinico Sant' Ambrogio, Milano (Italy); Del Furia, Francesca [Unità Operativa di Cardiologia, Azienda Ospedaliera di Melegnano, Milano (Italy); Inglese, Luigi [Interventistica Cardiovascolare, Gruppo Sanitario Policlinico di Monza, Milano (Italy)

    2016-01-15

    The completely absorbable stents represent one of the latest innovations in the field of interventional cardiology, prospecting the possibility of “vascular repair”. In the published trials (ABSORB Cohort A and B, ABSORB EXTEND, and ABSORB II, III and IV) chronic total occlusions (CTOs) were considered an exclusion criteria. More recently the CTO-ABSORB pilot study demonstrated the safety and feasibility of bioresorbable vascular scaffold (BVS) use in case of CTO recanalization. We present the first case, to our knowledge, of in-stent occlusion successfully treated with an everolimus-eluting BVS and discuss its potential advantages in such kind of lesions.

  19. Bioresorbable vascular scaffold (BVS) for in-stent chronic total occlusion: Antegrade recanalization and IVUS-guided BVS implantation by radial access

    International Nuclear Information System (INIS)

    Medda, Massimo; Casilli, Francesco; Bande, Marta; Latini, Maria Giulia; Ghommidh, Mehdi; Del Furia, Francesca; Inglese, Luigi

    2016-01-01

    The completely absorbable stents represent one of the latest innovations in the field of interventional cardiology, prospecting the possibility of “vascular repair”. In the published trials (ABSORB Cohort A and B, ABSORB EXTEND, and ABSORB II, III and IV) chronic total occlusions (CTOs) were considered an exclusion criteria. More recently the CTO-ABSORB pilot study demonstrated the safety and feasibility of bioresorbable vascular scaffold (BVS) use in case of CTO recanalization. We present the first case, to our knowledge, of in-stent occlusion successfully treated with an everolimus-eluting BVS and discuss its potential advantages in such kind of lesions.

  20. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  1. Randomized Comparison of Final Kissing Balloon Dilatation Versus No Final Kissing Balloon Dilatation in Patients With Coronary Bifurcation Lesions Treated With Main Vessel Stenting. Five Year Clinical Outcome in The Nordic-Baltic Bifurcation Study III

    DEFF Research Database (Denmark)

    Niemelä, Matti; Holm, Niels R; Kervinen, Kari

    2015-01-01

    Background- It is unknown whether the preferred 1-stent bifurcation stenting approach with stenting of the main vessel (MV) and optional side branch stenting using drug-eluting stents should be finalized by a kissing balloon dilatation (FKBD). Therefore, we compared strategies of MV stenting......, or stent thrombosis within 6 months. The 6-month major adverse cardiac event rates were 2.1% and 2.5% (P=1.00) in the FKBD and no-FKBD groups, respectively. Procedure and fluoroscopy times were longer and more contrast media was needed in the FKBD group than in the no-FKBD group. Three hundred twenty...... angiographic side branch (re)stenosis, especially in patients with true bifurcation lesions. The simple no-FKBD procedures resulted in reduced use of contrast media and shorter procedure and fluoroscopy times. Long-term data on stent thrombosis are needed. Clinical Trial Registration- URL: http...

  2. Association of Sirolimus Use With Risk for Skin Cancer in a Mixed-Organ Cohort of Solid-Organ Transplant Recipients With a History of Cancer.

    Science.gov (United States)

    Karia, Pritesh S; Azzi, Jamil R; Heher, Eliot C; Hills, Victoria M; Schmults, Chrysalyne D

    2016-05-01

    Solid-organ transplant recipients (OTRs) are at an increased risk for skin cancer. Prior studies have demonstrated a reduced incidence of skin cancer in renal OTRs treated with sirolimus. However, little information exists on the use of sirolimus for the prevention of skin cancer in nonrenal OTRs or those already diagnosed as having a posttransplant cancer. To compare subsequent skin cancer formation in a mixed-organ cohort of OTRs who were or were not treated with sirolimus after developing a posttransplant index cancer of any type. A 9-year retrospective cohort study at 2 academic tertiary care centers. Electronic medical records were reviewed for OTRs diagnosed as having a posttransplant cancer of any type to determine the type of organ transplanted, pretransplant and posttransplant cancer, and immunosuppressive medications. Patients underwent transplant from January 1, 2000, to December 31, 2008. Data were collected from July 30, 2011, to December 31, 2012, when follow-up was completed, and analyzed from April 28, 2013, to October 4, 2014. Factors associated with subsequent skin cancer development were evaluated via multivariate Cox regression analysis. Of 329 OTRs with an index posttransplant cancer (100 women and 229 men; mean [SD] age, 56 [19] years), 177 (53.8%) underwent renal transplant; 58 (17.6%), heart transplant; 54 (16.4%), lung transplant; 34 (10.3%), liver transplant; and 6 (1.8%), mixed-organ transplant. Ninety-seven OTRs (29.5%) underwent conversion to sirolimus therapy after diagnosis. One hundred thirty OTRs (39.5%) developed second posttransplant cancers, of which 115 cases (88.5%) were skin cancers. An 11.6% reduction in skin cancer risk was observed in the sirolimus-treated vs non-sirolimus-treated groups overall (26 of 97 [26.8%] vs 89 of 232 [38.4%]; P = .045) and among nonrenal OTRs only (8 of 34 [23.5%] vs 44 of 112 [39.3%], respectively), although the latter difference was not significant (P = .09). Independent predictors of

  3. Treatment of geographic atrophy with subconjunctival sirolimus: results of a phase I/II clinical trial.

    Science.gov (United States)

    Wong, Wai T; Dresner, Samuel; Forooghian, Farzin; Glaser, Tanya; Doss, Lauren; Zhou, Mei; Cunningham, Denise; Shimel, Katherine; Harrington, Molly; Hammel, Keri; Cukras, Catherine A; Ferris, Frederick L; Chew, Emily Y

    2013-04-26

    To investigate the safety and effects of subconjunctival sirolimus, an mTOR inhibitor and immunosuppressive agent, for the treatment of geographic atrophy (GA). The study was a single-center, open-label phase II trial, enrolling 11 participants with bilateral GA; eight participants completed 24 months of follow-up. Sirolimus (440 μg) was administered every 3 months as a subconjunctival injection in only one randomly assigned eye in each participant for 24 months. Fellow eyes served as untreated controls. The primary efficacy outcome measure was the change in the total GA area at 24 months. Secondary outcomes included changes in visual acuity, macular sensitivity, central retinal thickness, and total drusen area. The study drug was well tolerated with few symptoms and related adverse events. Study treatment in study eyes was not associated with structural or functional benefits relative to the control fellow eyes. At month 24, mean GA area increased by 54.5% and 39.7% in study and fellow eyes, respectively (P = 0.41), whereas mean visual acuity decreased by 21.0 letters and 3.0 letters in study and fellow eyes, respectively (P = 0.03). Substantial differences in mean changes in drusen area, central retinal thickness, and macular sensitivity were not detected for all analysis time points up to 24 months. Repeated subconjunctival sirolimus was well-tolerated in patients with GA, although no positive anatomic or functional effects were identified. Subconjunctival sirolimus may not be beneficial in the prevention of GA progression, and may potentially be associated with effects detrimental to visual acuity. (ClinicalTrials.gov number, NCT00766649.).

  4. Sirolimus Use in Liver Transplant Recipients With Hepatocellular Carcinoma: A Randomized, Multicenter, Open-Label Phase 3 Trial

    Science.gov (United States)

    Geissler, Edward K.; Schnitzbauer, Andreas A.; Zülke, Carl; Lamby, Philipp E.; Proneth, Andrea; Duvoux, Christophe; Burra, Patrizia; Jauch, Karl-Walter; Rentsch, Markus; Ganten, Tom M.; Schmidt, Jan; Settmacher, Utz; Heise, Michael; Rossi, Giorgio; Cillo, Umberto; Kneteman, Norman; Adam, René; van Hoek, Bart; Bachellier, Philippe; Wolf, Philippe; Rostaing, Lionel; Bechstein, Wolf O.; Rizell, Magnus; Powell, James; Hidalgo, Ernest; Gugenheim, Jean; Wolters, Heiner; Brockmann, Jens; Roy, André; Mutzbauer, Ingrid; Schlitt, Angela; Beckebaum, Susanne; Graeb, Christian; Nadalin, Silvio; Valente, Umberto; Turrión, Victor Sánchez; Jamieson, Neville; Scholz, Tim; Colledan, Michele; Fändrich, Fred; Becker, Thomas; Söderdahl, Gunnar; Chazouillères, Olivier; Mäkisalo, Heikki; Pageaux, Georges-Philippe; Steininger, Rudolf; Soliman, Thomas; de Jong, Koert P.; Pirenne, Jacques; Margreiter, Raimund; Pratschke, Johann; Pinna, Antonio D.; Hauss, Johann; Schreiber, Stefan; Strasser, Simone; Klempnauer, Jürgen; Troisi, Roberto I.; Bhoori, Sherrie; Lerut, Jan; Bilbao, Itxarone; Klein, Christian G.; Königsrainer, Alfred; Mirza, Darius F.; Otto, Gerd; Mazzaferro, Vincenzo; Neuhaus, Peter; Schlitt, Hans J.

    2016-01-01

    Background We investigated whether sirolimus-based immunosuppression improves outcomes in liver transplantation (LTx) candidates with hepatocellular carcinoma (HCC). Methods In a prospective-randomized open-label international trial, 525 LTx recipients with HCC initially receiving mammalian target of rapamycin inhibitor–free immunosuppression were randomized 4 to 6 weeks after transplantation into a group on mammalian target of rapamycin inhibitor–free immunosuppression (group A: 264 patients) or a group incorporating sirolimus (group B: 261). The primary endpoint was recurrence-free survival (RFS); intention-to-treat (ITT) analysis was conducted after 8 years. Overall survival (OS) was a secondary endpoint. Results Recurrence-free survival was 64.5% in group A and 70.2% in group B at study end, this difference was not significant (P = 0.28; hazard ratio [HR], 0.84; 95% confidence interval [95% CI], 0.62; 1.15). In a planned analysis of RFS rates at yearly intervals, group B showed better outcomes 3 years after transplantation (HR, 0.7; 95% CI, 0.48-1.00). Similarly, OS (P = 0.21; HR, 0.81; 95% CI, 0.58-1.13) was not statistically better in group B at study end, but yearly analyses showed improvement out to 5 years (HR, 0.7; 95% CI, 0.49-1.00). Interestingly, subgroup (Milan Criteria-based) analyses revealed that low-risk, rather than high-risk, patients benefited most from sirolimus; furthermore, younger recipients (age ≤60) also benefited, as well sirolimus monotherapy patients. Serious adverse event numbers were alike in groups A (860) and B (874). Conclusions Sirolimus in LTx recipients with HCC does not improve long-term RFS beyond 5 years. However, a RFS and OS benefit is evident in the first 3 to 5 years, especially in low-risk patients. This trial provides the first high-level evidence base for selecting immunosuppression in LTx recipients with HCC. PMID:26555945

  5. Bioerodible drug/eluting stent coating with highly controllable drug release rate and excellent vascular biocompatibility

    Czech Academy of Sciences Publication Activity Database

    Rypáček, František; Mulinková, Katarína; Bernátková, Markéta; Machová, Luďka; Lapčíková, Monika; Otsuka, Y.; Robinson, K. A.; Mulkey, S. P.; Baranowski, C.; Zablocki, J.; Blackburn, B. K.; Chronos, N.

    2005-01-01

    Roč. 96, 7A (2005), 209H-210H ISSN 0002-9149. [Annual Conference of Transcathetral Cardiovascular Therapeutics /17./. Washington, 16.10.2005-21.10.2005] R&D Projects: GA AV ČR IAA4050202 Institutional research plan: CEZ:AV0Z40500505 Keywords : drug delivery * polymer coating * stent Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.059, year: 2005

  6. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  7. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  8. 77 FR 35690 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2012-06-14

    ... Paclitaxel- February 22, 2012. Corp. Eluting Coronary Stent System (Monorail and Over- The-Wire Delivery...] February 22, 2012. Corp. Paclitaxel-Eluting Coronary Stent System (Monorail and Over-The-Wire Delivery.... Paclitaxel-Eluting Coronary Stent System (Monorail and Over-The-Wire Delivery Systems). P110023, FDA-2012-M...

  9. Drug-eluting stents vs. coronary artery bypass-grafting in coronary heart disease

    Directory of Open Access Journals (Sweden)

    Hagen, Anja

    2008-12-01

    Full Text Available Background: Coronary artery bypass graft (CABG and percutaneous revascularisations with implantation of drug-eluting stents (DES are important treatment methods in coronary heart disease (CHD. Research questions: The evaluation addresses questions on medical efficacy, health economic parameters as well as ethic, social and legal implications in the use of DES vs. CABG in CHD patients. Methods: A systematic literature search was conducted in December 2006 in the most important electronic databases beginning from 2004. Register data and controlled clinical studies were included in the evaluation. Additionally, a health economic modelling was conducted. Results: Medical evaluation: The literature search yielded 2,312 hits. 14 publications about six controlled clinical studies and five publications about two registers were included into the evaluation. Register data showed low mortality (0.2% to 0.7% and low rates of myocardial infarction (0.5% to 1.4% during hospital stay. In patients with stenosis of the left anterior descending coronary artery one study showed in several analyses a significantly higher rate of reinterventions and a significantly higher rate of repeated angina pectoris for DES up to two years after the implantation (16.8% vs. 3.6% and 35% vs. 8%. In patients with left main coronary artery stenosis two studies revealed a significantly higher survival without myocardial infarction and stroke for DES up to one year (96% vs. 79% and 95% vs. 91% and two studies a significantly higher rate of revascularisations up to two years (20% vs. 4% and 25% vs. 5% after the primary intervention. In patients with multivessel disease, one study found a significantly higher mortality and myocardial infarction rate for CABG at one year (2.7% vs. 1.0% and 4.2% vs. 1.3%. The rate of revascularisations was significantly higher in two studies up to two years after DES implantation (8.5% vs. 4.2% and 14.2% vs. 5.3%. The rate at repeated angina pectoris was

  10. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    Aims: Data are limited on the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with coronary stents. We examined the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with percutaneous coronary intervention (PCI). Methods and results......: All patients who underwent stent implantation from 2002 to 2005 were identified in the Western Denmark Heart Registry. The hazard ratio (HR) for death associated with stent thrombosis or in-stent restenosis was estimated with a Cox regression analysis with stent thrombosis or in-stent restenosis...... as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  12. Stent thrombosis and restenosis: what have we learned and where are we going? The Andreas Grüntzig Lecture ESC 2014

    Science.gov (United States)

    Byrne, Robert A.; Joner, Michael; Kastrati, Adnan

    2015-01-01

    Modern-day stenting procedures leverage advances in pharmacotherapy and device innovation. Patients treated with contemporary antiplatelet agents, peri-procedural antithrombin therapy and new-generation drug-eluting stents (DES) have excellent outcomes over the short to medium term. Indeed, coupled with the reducing costs of these devices in most countries there remain very few indications where patients should be denied treatment with standard-of-care DES therapy. The two major causes of stent failure are stent thrombosis (ST) and in-stent restenosis (ISR). The incidence of both has reduced considerably in recent years. Current clinical registries and randomized trials with broad inclusion criteria show rates of ST at or stent failure neoatherosclerotic change within the stented segment represents a final common pathway for both thrombotic and restenotic events. In future, a better understanding of the pathogenesis of this process may translate into improved late outcomes. Moreover, the predominance of non-stent-related disease as a cause of subsequent myocardial infarction during follow-up highlights the importance of lifestyle and pharmacological interventions targeted at modification of the underlying disease process. Finally, although recent developments focus on strategies which circumvent the need for chronically indwelling stents—such as drug-coated balloons or fully bioresorbable stents—more data are needed before the wider use of these therapies can be advocated. PMID:26417060

  13. Interstitial pneumonitis is a frequent complication in liver transplant recipients treated with sirolimus.

    LENUS (Irish Health Repository)

    Morcos, A

    2012-06-01

    Sirolimus is a powerful immunosuppressive drug which is being used increasingly after liver transplantation because of its renal sparing and anti-tumour effects. It has been associated with uncommon, but potentially fatal, interstitial pneumonitis.

  14. A retrograde y-stenting of the trachea for treatment of mediastinal fistula in an unusual situation

    Directory of Open Access Journals (Sweden)

    Hohenforst-Schmidt W

    2017-05-01

    FS is presented. Keywords: stents, drug-eluting stents, cancer, benign stenosis

  15. Gateways to clinical trials.

    Science.gov (United States)

    Tomillero, A; Moral, M A

    2010-01-01

    (-)-Epigallocatechin gallate, Abafungin, ACE-031, Adapalene/benzoyl peroxide, AE-37, Aflibercept, AGS-003, Albiglutide, Alemtuzumab, Aliskiren fumarate, ALT-801, AN-2728, Anacetrapib, API, Aprepitant, ARQ-197, Ascorbic acid, Atazanavir sulfate, ATN-224, AVI-4658, Azacitidine, Azelnidipine; Belinostat, Bevacizumab, BI-2536, Biphasic insulin aspart, Bortezomib, Bovine lactoferrin, Bryostatin 1, Budesonide/formoterol fumarate; cAC10, Canfosfamide hydrochloride, Cediranib, Clofarabine, Cocaine conjugate vaccine; Darbepoetin alfa, Dasatinib, Denosumab, Disomotide, Doripenem, Dovitinib Lactate, Dronedarone hydrochloride, Drospirenone/estradiol, Dutasteride; Ecogramostim, Entinostat, Enzastaurin hydrochloride, Erlotinib hydrochloride, Everolimus, Exenatide, Ezetimibe, Ezetimibe/simvastatin; Fampridine, Fenretinide LXS, FFR-factor VIIa, Fingolimod hydrochloride, Frovatriptan; Gefitinib, Gimatecan, GP-2/GM-CSF; Iloperidone, Imatinib mesylate, Indibulin, Ipilimumab, Ivabradine hydrochloride; Lactobacillus rhamnosus, Lapatinib ditosylate, LC-07, Lenalidomide, Linifanib, Liposomal doxorubicin, Liposomal vincristine, Litenimod, Lutein; M-118, MDX-1401, MEDI-528, Midostaurin, Miglustat, MK-0657; Natalizumab, Nesiritide, NGR-TNF, Niacin/simvastatin; Obatoclax mesylate, Olaparib, Omacetaxine mepesuccinate; Paclitaxel nanoparticles, Paclitaxel-eluting stent, Palonosetron hydrochloride, Pazopanib hydrochloride, Pegfilgrastim, Pemetrexed disodium, PER.C-flu, Perifosine, PF-02341066, Pimecrolimus, Pitrakinra, Plerixafor hydrochloride, Posaconazole; Rasburicase, Recombinant human relaxin H2, ReoT3D, Retaspimycin hydrochloride, Riferminogene pecaplasmid, Rindopepimut, Romiplostim, Ronacaleret hydrochloride, Rosuvastatin calcium, Rotigotine; Sagopilone, sALP-FcD10, SAR-245409, SCH-697243, Selumetinib, Sirolimus-eluting stent, SIR-Spheres, Sitagliptin phosphate monohydrate, Sitaxentan sodium, Sorafenib, Sunitinib malate; Tadalafil, Tandutinib, Tasimelteon, Temsirolimus, Teriparatide

  16. 5A/6A Polymorphism of the Stromelysin-1 Gene and Angiographic Restenosis After Coronary Artery Stenting

    Directory of Open Access Journals (Sweden)

    Kuan-Rau Chiou

    2005-11-01

    Conclusion: There is a low frequency of the stromelysin-1 promoter 5A allele in the Chinese population in Taiwan. How stromelysin-1 5A/6A polymorphism affects ISR appears to be linked to angina status. These results merit further study to identify patients carrying genotypes which put them at increased risk of ISR, and which matrix metalloproteinase inhibitors or drug-eluting stents are more effective for those at risk.

  17. Sirolimus formulation with improved pharmacokinetic properties produced by a continuous flow method.

    Science.gov (United States)

    Solymosi, Tamás; Angi, Réka; Basa-Dénes, Orsolya; Ránky, Soma; Ötvös, Zsolt; Glavinas, Hristos; Filipcsei, Genovéva; Heltovics, Gábor

    2015-08-01

    The oral bioavailability of Sirolimus is limited by poor dissolution of the compound in the gastrointestinal tract resulting in a low bioavailability and large inter-individual differences in blood levels. Several different formulation approaches were applied to overcome these disadvantageous pharmacokinetic properties including the marketed oral solution and a tablet form containing wet milled nanocrystals. These approaches deliver improved pharmacokinetics, yet, they share the characteristics of complex production method and composition. We have developed a nanostructured Sirolimus formulation prepared by the controlled continuous flow precipitation of the compound from its solution in the presence of stabilizers. We have shown that contrary to the batch production the process could be easily intensified and scaled up; apparently the uniformity of the precipitation is heavily dependent on the production parameters, most likely the mixing of the solvent and antisolvent. We compared the physicochemical and pharmacokinetic properties of the nanostructured formula with the marketed nanoformula. We found that our method produces particles in the size range of less than 100nm. The solid form redispersed instantaneously in water and in biorelevant media. Both the solid form and the redispersed colloid solution showed excellent stability even in accelerated test conditions. The oral administration of the nanostructured formula resulted in faster absorption, higher exposure and higher trough concentrations when compared to the marked form. These advantageous properties could allow the development of solid oral Sirolimus formulae with lower strength and gel based topical delivery systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Study design of the influence of SErotonin inhibition on patients with RENAl impairment or diabetes undergoing drug-eluting stent implantation (SERENADE) study: A multicenter, open-label, prospective, randomized study.

    Science.gov (United States)

    Lee, Seung-Ah; Suh, Jung-Won; Park, Jin Joo; Yoon, Chang-Hwan; Cho, Young-Suk; Youn, Tae-Jin; Chae, In-Ho; Kim, Hyo-Soo; Kim, Sang-Hyun; Choi, Dong-Ju

    2015-07-01

    The rates of stent failure after percutaneous coronary intervention have decreased since the introduction of the drug-eluting stent (DES). However, chronic kidney disease (CKD) and diabetes mellitus (DM) remain strong clinical predictors of poor prognosis despite DES implantation. Sarpogrelate, a selective serotonin (5-hydroxytryptamine (HT)2a [5-HT2A]) receptor antagonist, has antiproliferative effects, reducing neointimal hyperplasia and smooth muscle cell proliferation, as well as potent antiplatelet action, inhibiting 5-HT-induced platelet aggregation. However, efficacy and safety data for sarpogrelate in patients with CKD or DM are limited. We aim to determine whether sarpogrelate has beneficial effects in patients with CDK or DM treated with DES implantation. The SERENADE trial is a multicenter, open-label, prospective, randomized study that will test the superiority of triple anti-platelet therapy (TAT; aspirin, clopidogrel, and sarpogrelate) to conventional dual antiplatelet therapy (DAT; aspirin and clopidogrel) in preventing late lumen loss 9 months after the index procedure in patients with CKD or DM. A total of 220 patients diagnosed with coronary artery disease with DM or CKD will be randomized to the TAT or DAT groups (1:1 ratio) after DES implantation. The primary endpoint is late lumen loss at 9 months assessed by quantitative coronary angiography. Secondary efficacy endpoints are composites of major adverse cardiovascular events including cardiac death, nonfatal myocardial infarction, and target lesion revascularization. Secondary safety endpoints are major bleeding events and hepatic or renal impairment. The SERENADE trial will provide insight on the efficacy of adjunctive therapy with sarpogrelate after DES implantation for patients with high-risk profiles such as CKD or DM. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov NCT02294643). Copyright © 2015. Published by Elsevier Inc.

  19. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation

  20. Clinical proof-of-concept trial to assess the therapeutic effect of sirolimus in patients with autosomal dominant polycystic kidney disease: SUISSE ADPKD study

    Directory of Open Access Journals (Sweden)

    Wüthrich Rudolf P

    2007-09-01

    Full Text Available Abstract Background Currently there is no effective treatment available to retard cyst growth and to prevent the progression to end-stage renal failure in patients with autosomal dominant polycystic kidney disease (ADPKD. Evidence has recently been obtained from animal experiments that activation of the mammalian target of rapamycin (mTOR signaling pathway plays a crucial role in cyst growth and renal volume expansion, and that the inhibition of mTOR with rapamycin (sirolimus markedly slows cyst development and renal functional deterioration. Based on these promising results in animals we have designed and initiated the first randomized controlled trial (RCT to examine the effectiveness, safety and tolerability of sirolimus to retard disease progression in ADPKD. Method/design This single center, randomised controlled, open label trial assesses the therapeutic effect, safety and tolerability of the mTOR inhibitor sirolimus (Rapamune® in patients with autosomal dominant polycystic kidney disease and preserved renal function. The primary outcome will be the inhibition of kidney volume growth measured by magnetic resonance imaging (MRI volumetry. Secondary outcome parameters will be preservation of renal function, safety and tolerability of sirolimus. Discussion The results from this proof-of-concept RCT will for the first time show whether treatment with sirolimus effectively retards cyst growth in patients with ADPKD. Trial registration NCT00346918