WorldWideScience

Sample records for singly ionized magnesium

  1. On the ionization of interstellar magnesium

    International Nuclear Information System (INIS)

    Gurzadyan, G.A.

    1977-01-01

    It has been shown that two concentric ionization zones of interstellar magnesium must exist around each star: internal, with a radius coinciding with that of the zone of hydrogen ionization Ssub(H); and external, with a radius greater than Ssub(H), by one order. Unlike interstellar hydrogen, interstellar magnesium is ionized throughout the Galaxy. It also transpires that the ionizing radiation of ordinary hot stars cannot provide for the observed high degree of ionization of interstellar magnesium. The discrepance can be eliminated by assuming the existence of circumstellar clouds or additional ionization sources of interstellar magnesium (X-ray background radiation, high-energy particles, etc.). Stars of the B5 and BO class play the main role in the formation of ionization zones of interstellar magnesium; the contribution of O class stars is negligible (<1%). (Auth.)

  2. Ionized magnesium in plasma and erythrocytes for the assessment of low magnesium status in alcohol dependent patients.

    Science.gov (United States)

    Ordak, Michal; Maj-Zurawska, Magdalena; Matsumoto, Halina; Bujalska-Zadrozny, Magdalena; Kieres-Salomonski, Ilona; Nasierowski, Tadeusz; Muszynska, Elzbieta; Wojnar, Marcin

    2017-09-01

    Studies on the homeostasis of magnesium in alcohol-dependent patients have often been characterized by low hypomagnesemia detection rates. This may be due to the fact that the content of magnesium in blood serum constitutes only 1% of the average magnesium level within the human body. However, the concentration of ionized magnesium is more physiologically important and makes up 67% of the total magnesium within a human organism. There are no data concerning the determination of the ionized fraction of magnesium in patients addicted to alcohol and its influence on mental health status. This study included 100 alcohol-dependent patients and 50 healthy subjects. The free magnesium fraction was determined using the potentiometric method by means of using ion-selective electrodes. The total magnesium level was determined by using a biochemical Indiko Plus analyzer. In this study, different psychometric scales were applied. Our results confirm the usefulness of ionized magnesium concentrations in erythrocytes and plasma as a diagnostic parameter of low magnesium status in alcohol-dependent patients. The lower the concentration of ionized magnesium, the worse the quality of life an alcohol-dependent person might experience. In the case of total magnesium, no such correlation was determined. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma

    DEFF Research Database (Denmark)

    Rayana, M.C. Ben; Burnett, R.W.; Covington, A.K.

    2008-01-01

    Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal [in this document, "plasma" refers to circulating...... plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or "blood"), plasma separated from blood cells, or serum]. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration...... of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength. The recommended name is "the concentration of ionized magnesium in plasma". Based on this guideline, results will be approximately 3% higher than the true substance concentration and 4...

  4. Total and ionized serum magnesium and calcium levels during magnesium sulfate administration for preterm labor

    Science.gov (United States)

    Kim, Won Hee; An, Yuna; Moon, Jong Ho; Noh, Eun Ji; Kim, Jong Woon

    2018-01-01

    Objective This study aimed to estimate the association between total and ionized magnesium, and the changes in serum magnesium and calcium levels in patients with preterm labor during magnesium sulfate (MgSO4) administration. Methods The study population included 64 women who were candidates for intravenous MgSO4 treatment for preterm labor. Serial blood samples were taken and measured total magnesium (T-Mg), ionized magnesium (I-Mg), total calcium (T-Ca), and ionized calcium (I-Ca) levels every one-week interval (1st, 2nd, 3rd). Results There was no significant difference in T-Mg and I-Mg levels during MgSO4 administration (P>0.05). There was no significant difference in T-Ca and I-Ca levels during MgSO4 administration (P>0.05). Compared before and after administration of MgSO4, T-Mg and I-Mg levels and T-Ca levels were changed allow statistically significant (P0.05). There was significant correlation between levels of I-Mg and T-Mg (I-Mg=0.395×T-Mg+0.144, P<0.01). Conclusion There were no significant differences in serum Mg and Ca levels during MgSO4 administration for preterm labor. Compared to the before and after administration of MgSO4, only I-Ca levels were not substantially changed. There are significant correlations between I-Mg and T-Mg levels during administration of MgSO4 and I-Mg level seemed to have more correlation with adverse effect than T-Mg. PMID:29372150

  5. Molecular single photon double K-shell ionization

    International Nuclear Information System (INIS)

    Penent, F.; Nakano, M.; Tashiro, M.; Grozdanov, T.P.; Žitnik, M.; Carniato, S.; Selles, P.; Andric, L.; Lablanquie, P.; Palaudoux, J.; Shigemasa, E.; Iwayama, H.; Hikosaka, Y.; Soejima, K.; Suzuki, I.H.; Kouchi, N.; Ito, K.

    2014-01-01

    We have studied single photon double K-shell ionization of small molecules (N 2 , CO, C 2 H 2n (n = 1–3), …) and the Auger decay of the resulting double core hole (DCH) molecular ions thanks to multi-electron coincidence spectroscopy using a magnetic bottle time-of-flight spectrometer. The relative cross-sections for single-site (K −2 ) and two-site (K −1 K −1 ) double K-shell ionization with respect to single K-shell (K −1 ) ionization have been measured that gives important information on the mechanisms of single photon double ionization. The spectroscopy of two-site (K −1 K −1 ) DCH states in the C 2 H 2n (n = 1–3) series shows important chemical shifts due to a strong dependence on the C-C bond length. In addition, the complete cascade Auger decay following single site (K −2 ) ionization has been obtained

  6. Electron-impact single and double ionization of W

    International Nuclear Information System (INIS)

    Pindzola, M S; Loch, S D; Foster, A R

    2017-01-01

    Electron-impact single and double ionization cross sections for the W atom are calculated using a semi-relativistic distorted-wave method. The cross sections include contributions from single direct ionization, double direct ionization and excitation-autoionization. Branching ratio calculations are made to determine whether an excitation may contribute to single or double ionization. We check the accuracy of the semi-relativistic distorted-wave calculations for direct ionization of various subshells by comparison with fully-relativistic distorted-wave calculations. We also check the accuracy of the perturbative distorted-wave calculations for direct ionization of the outer most subshells by comparison with non-perturbative time-dependent close-coupling calculations. (paper)

  7. Selectivity coefficients of ion-selective magnesium electrodes used for simultaneous determination of magnesium and calcium ions.

    Science.gov (United States)

    Maj-Zurawska, Magdalena; Lewenstam, Andrzej

    2011-12-15

    Membrane ion-selective magnesium electrodes are commonly used to determine ionized magnesium concentration in blood serum and intracellular fluid by potentiometric clinical analyzers. The selectivity of these electrodes against calcium ion is typically insufficient to avoid calcium interference in blood serum analysis. For this reason the selectivity coefficient for calcium ion has to be studied to make possible any mathematical corrections for calcium ion influence. Existing methods relate to the thermodynamic concept of ISE response which suggest a single constant value of the selectivity coefficient and slope that are stable over the concentration ranges of calcium and magnesium ions in the samples. Unfortunately, this rarely happens, and we rather observe dependences on solution and membrane composition, readout time, matrices (anticoagulant, vial coats) that justify usage of apparent selectivities and slopes. To get the practical insight into the response of magnesium ion-selective electrodes a novel method for estimating the selectivity coefficients and the slope of the electrode characteristics is proposed. This method is an effective starting point for selecting electrodes and designing transient signal software in a potentiometric clinical analyzer. The method allows obtaining the ionized magnesium concentration in blood serum with minimal possible error by addressing the assessed targets, i.e. apparent selectivity and slope. The method is based on computer simulation and on the Nicolsky-Eisenman equation. Usually only a few iterations are needed to obtain stable congruent results. The method presented is particularly useful in conditions where is not possible to obtain calibration curve, which is typical for clinical analyzer where at most three point calibration is performed. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Ionization of xenon by electrons: Partial cross sections for single, double, and triple ionization

    International Nuclear Information System (INIS)

    Mathur, D.; Badrinathan, C.

    1987-01-01

    High-sensitivity measurements of relative partial cross sections for single, double, and triple ionization of Xe by electron impact have been carried out in the energy region from threshold to 100 eV using a crossed-beam apparatus incorporating a quadrupole mass spectrometer. The weighted sum of the relative partial cross sections at 50 eV are normalized to the total ionization cross section of Rapp and Englander-Golden to yield absolute cross-section functions. Shapes of the partial cross sections for single and double ionization are difficult to account for within a single-particle picture. Comparison of the Xe + data with 4d partial photoionization cross-section measurements indicates the important role played by many-body effects in describing electron-impact ionization of high-Z atoms

  9. Single and multiple ionization of sulfur atoms by electron impact

    International Nuclear Information System (INIS)

    Ziegler, D.L.

    1982-01-01

    Laboratory measurements of the cross sections for single, double, triple, and quadruple ionization of sulfur atoms by electron impact are presented for collision energies from threshold to 500 eV. The cross sections for single ionization of sulfur are measured relative to those of several elements whose absolute cross sections for single ionization are known. Cross sections for each multiple ionization process are then measured relative to those for single ionization. The configuration and operation of the apparatus for these measurements are described. The possible effects of excited sulfur reactants are examined, and the reported cross sections are felt to be characteristic of ground state sulfur atoms

  10. Time expansion chamber and single ionization cluster measurement

    International Nuclear Information System (INIS)

    Walenta, A.H.

    1978-10-01

    The time expansion chamber (TEC), a new type of drift chamber, allows the measurement of microscopic details of ionization. The mean drift time interval from subsequent sngle ionization clusters of a relativistic particle in the TEC can be made large enough compared to the width of a anode signal to allow the recording of the clusters separately. Since single primary electrons can be detected, the cluster counting would allow an improved particle separation using the relativistic rise of primary ionization. In another application, very high position accuracy for track detectors or improved energy resolution may be obtained. Basic ionization phenomena and drift properties can be measured at the single electron level

  11. Single and double ionization of gallium by electron impact

    Indian Academy of Sciences (India)

    Electron impact single and double ionization cross sections of gallium have been calcu- ... The experimental data on single ionization have been compared with the empirical and ..... and multiplication sign curve (¢¢¢) represent present.

  12. Recent advances in magnesium assessment: From single selective sensors to multisensory approach.

    Science.gov (United States)

    Lvova, Larisa; Gonçalves, Carla Guanais; Di Natale, Corrado; Legin, Andrey; Kirsanov, Dmitry; Paolesse, Roberto

    2018-03-01

    The development of efficient analytical procedures for the selective detection of magnesium is an important analytical task, since this element is one of the most abundant metals in cells and plays an essential role in a plenty of cellular processes. Magnesium misbalance has been related to several pathologies and diseases both in plants and animals, as far as in humans, but the number of suitable methods for magnesium detection especially in life sample and biological environments is scarce. Chemical sensors, due to their high reliability, simplicity of handling and instrumentation, fast and real-time in situ and on site analysis are promising candidates for magnesium analysis and represent an attractive alternative to the standard instrumental methods. Here the recent achievements in the development of chemical sensors for magnesium ions detection over the last decade are reviewed. The working principles and the main types of sensors applied are described. Focus is placed on the optical sensors and multisensory systems applications for magnesium assessment in different media. Further, a critical outlook on the employment of multisensory approach in comparison to single selective sensors application in biological samples is presented. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Features of single and double ionization processes induced by few cycle laser pulses

    International Nuclear Information System (INIS)

    Starace, A.F.

    2005-01-01

    Full text: The advent of laser pulses with attosecond pulse lengths ushers in the regime of few cycle laser pulse interactions with atoms and ions, including the interesting cases of single and half cycle laser pulses. In this talk I will present results of recent studies of single electron ionization/detachment and double electron ionization/detachment produced by a few cycle laser pulse. For the former case, we shall demonstrate that the ionized/detached electron momentum distribution reflects the interference of electron probability wave packets produced by each half cycle of a single cycle pulse. Also, that the ionized/detached electron momentum distribution uniquely characterizes the phase of the single cycle laser pulse within the laser pulse envelope. Regarding double ionization/detachment, our numerical experiments have shown that single cycle and double half cycle pulses produce different electron angular distributions. Some double ionization features that are present only in the single cycle case can only have been produced by electron impact ionization during rescattering of an initially ionized electron and thus represent a sensitive measure of the rescattering process. Refs. 2 (author)

  14. Ionization dual-zone static detector having single radioactive source

    International Nuclear Information System (INIS)

    Ried, L. Jr.; Wade, A.L.

    1977-01-01

    This ionization detector or combustion product detector includes a single radioactive source located in an ionization chamber, and the ionization chamber includes portions comprising a reference zone and a signal zone. Electrical circuitry connected to the reference and signal zones provides an output signal directly related to changes in voltages across the signal zone in relation to the amount of particulates of combustion present in the ionization chamber

  15. Effect of Low-Dose (Single-Dose Magnesium Sulfate on Postoperative Analgesia in Hysterectomy Patients Receiving Balanced General Anesthesia

    Directory of Open Access Journals (Sweden)

    Arman Taheri

    2015-01-01

    Full Text Available Background and Aim. Aparallel, randomized, double blinded, placebo-controlled trial study was designed to assess the efficacy of single low dose of intravenous magnesium sulfate on post-total abdominal hysterectomy (TAH pain relief under balanced general anesthesia. Subject and Methods. Forty women undergoing TAH surgery were assigned to two magnesium sulfate (N=20 and normal saline (N=20 groups randomly. The magnesium group received magnesium sulfate 50 mg·kg−1 in 100 mL of normal saline solution i.v as single-dose, just 15 minutes before induction of anesthesia whereas patients in control group received 100 mL of 0.9% sodium chloride solution at the same time. The same balanced general anesthesia was induced for two groups. Pethidine consumption was recorded over 24 hours precisely as postoperative analgesic. Pain score was evaluated with Numeric Rating Scale (NRS at 0, 6, 12, and 24 hours after the surgeries. Results. Postoperative pain score was lower in magnesium group at 6, 12, and 24 hours after the operations significantly (P<0.05. Pethidine requirement was significantly lower in magnesium group throughout 24 hours after the surgeries (P=0.0001. Conclusion. Single dose of magnesium sulfate during balanced general anesthesia could be considered as effective and safe method to reduce postoperative pain and opioid consumption after TAH.

  16. The ratio of double to single ionization of helium: The relationship of photon and bare charged particle impact ionization

    International Nuclear Information System (INIS)

    Manson, S.T.

    1994-01-01

    In this paper the author derives expressions for the ratio of double to single ionization of helium from its ground state, by both single photons, and charged particle impact. He shows that in the limit of large reduced incident energy T of a charged particle, that the ratio of the double to single ionization cross sections at some energy transfer ΔE is equal to the ratio of photoionization cross sections for a photon of energy hν = ΔE, independent of T. He then goes on to find a relationship for this ionization ratio which is not restricted to some specific energy transfer, and shows that the double to single ionization cross section ratio approaches an asymtotic limit for large enough T

  17. K-Shell Photoabsorption Cross Sections for the Magnesium Isonuclear Sequence

    Science.gov (United States)

    Abdel-Naby, Shahin; Hasoglu, Fatih; Gorczyca, Thomas

    2011-05-01

    With the improved spectral resolution of launched X-ray telescopes, there is a demand for highly-accurate K-shell photoabsorption cross sections. Such data are needed for modeling astrophysical plasmas, interpreting the observed spectra from distant cosmic emitters, and determining the elemental abundances of the interstellar medium (ISM). Here we present new calculations for photoabsorption of the entire Mg isonuclear sequence using state-of-the-art R-matrix methods, including important spectator Auger broadening and inner-shell relaxation effects. Unlike our earlier work on carbon, oxygen, and neon ions, and the present work on multiply-ionized magnesium, the calculations for neutral Mg and singly-ionized Mg+ are complicated by additional M-shell occupancy, which leads to a larger R-matrix box and difficulties in implementing the quantum defect theoretical spectator Auger decay method for low-lying resonances. With the improved spectral resolution of launched X-ray telescopes, there is a demand for highly-accurate K-shell photoabsorption cross sections. Such data are needed for modeling astrophysical plasmas, interpreting the observed spectra from distant cosmic emitters, and determining the elemental abundances of the interstellar medium (ISM). Here we present new calculations for photoabsorption of the entire Mg isonuclear sequence using state-of-the-art R-matrix methods, including important spectator Auger broadening and inner-shell relaxation effects. Unlike our earlier work on carbon, oxygen, and neon ions, and the present work on multiply-ionized magnesium, the calculations for neutral Mg and singly-ionized Mg+ are complicated by additional M-shell occupancy, which leads to a larger R-matrix box and difficulties in implementing the quantum defect theoretical spectator Auger decay method for low-lying resonances. This work was funded in part by NASA's Astronomy Physics Research and Analysis (APRA) program.

  18. The Importance of Magnesium in the Human Body: A Systematic Literature Review

    DEFF Research Database (Denmark)

    Glasdam, Sidsel-Marie; Glasdam, Stinne; Peters, Günther H.J.

    2016-01-01

    Magnesium, the second and fourth most abundant cation in the intracellular compartment and whole body, respectively, is of great physiologic importance. Magnesium exists as bound and free ionized forms depending on temperature, pH, ionic strength, and competing ions. Free magnesium participates...

  19. K-SHELL PHOTOABSORPTION OF MAGNESIUM IONS

    Energy Technology Data Exchange (ETDEWEB)

    Hasoğlu, M. F. [Department of Computer Engineering, Hasan Kalyoncu University, 27100 Sahinbey, Gaziantep (Turkey); Abdel-Naby, Sh. A. [Department of Physics, Auburn University, Auburn, AL 36849 (United States); Gatuzz, E.; Mendoza, C. [Centro de Física, Instituto Venezolano de Investigaciones Científicas, Caracas 1020 (Venezuela, Bolivarian Republic of); García, J. [Harvard-Smithsonian Center for Astrophysics, MS-6, 60 Garden Street, Cambridge, MA 02138 (United States); Kallman, T. R. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Gorczyca, T. W. [Department of Physics, Western Michigan University, Kalamazoo, MI 49008-5252 (United States)

    2014-09-01

    X-ray photoabsorption cross sections have been computed for all magnesium ions with three or more electrons using the R-matrix method. A comparison with other available data for Mg II-Mg X shows good qualitative agreement in the resultant resonance shapes. However, for the lower ionization stages, and for singly ionized Mg II in particular, the previous R-matrix results overestimate the K-edge position due to the neglect of important orbital relaxation effects, and a global shift downward in photon energy of those cross sections is therefore warranted. We have found that the cross sections for Mg I and Mg II are further complicated by the M-shell (n = 3) occupancy. As a result, the treatment of spectator Auger decay of 1s → np resonances using a method based on multichannel quantum defect theory and an optical potential becomes problematic, making it necessary to implement an alternative, approximate treatment of Auger decay for neutral Mg I. The new cross sections are used to fit the Mg K edge in XMM-Newton spectra of the low-mass X-ray binary GS 1826-238, where most of the interstellar Mg is found to be in ionized form.

  20. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  1. Neutron-Phonon Interaction Studies in Copper, Zinc and Magnesium Single Crystals

    International Nuclear Information System (INIS)

    Maliszewski, E.; Sosnowski, J.; Blinowski, K.; Kozubowski, J.; Padlo, L.; Sledziewska, D.

    1963-01-01

    The phonon dispersion relations in copper single crystals has been studied by means of a triple-axis crystal neutron spectrometer. In the [100] direction the transversal branch, not reported in the papers of Cabie and Jacrot, has been found. This branch fits well to the recent data of sound velocity; however, it differs partly from the X-ray results of Jacobsen. For the longitudinal branch in the [100] direction the dispersion curve obtained by Cribier and Jacrot is lying well above the Jacobsen's curve, and the experimental points reported in the present paper support the results of Cribier and Jacrot. The phonon dispersion relations in zinc and magnesium single crystals has been studied using the cold neutron method and by means of a triple-axis crystal neutron spectrometer as well. The scattering surfaces in the [1010] plane were traced, the AT and AL branches found and the phonon dispersion relations in the [001] and [010] directions obtained. The results have been compared with those obtained by Johnson with X-rays. In the [001] direction the present results fit well lo Johnson's foe the AL branch. In the [010] direction for the AT branch a large discrepancy has been found between Johnson's and the present results. Some explanation of this discrepancy is given. Similar measurements in the same directions in magnesium single crystals are under way and will be reported. (author) [fr

  2. Ionization in matrix-assisted laser desorption/ionization: singly charged molecular ions are the lucky survivors.

    Science.gov (United States)

    Karas, M; Glückmann, M; Schäfer, J

    2000-01-01

    A new model for the ionization processes in UV matrix-assisted laser desorption/ionization (MALDI) which accounts for the major phenomena observed is presented and discussed. The model retains elements of earlier approaches, such as photoionization and photochemical reactions, but it redefines these in the light of new working questions, most importantly why only singly charged ions are detected. Based on experimental evidence, the formation of singly and multiply charged clusters by a deficiency/excess of ions and also by photoionization and subsequent photochemical processes is pointed out to be the major ionization processes, which typically occur in parallel. The generation of electrons and their partial loss into the surrounding vacuum and solid, on the one hand, results in a positively charged ion-neutral plume facilitating a high overall ionization yield. On the other hand, these electrons, and also the large excess of protonated matrix ions in the negative ion mode, induce effective ion reneutralization in the plume. These neutralization processes are most effective for the highly charged cluster ions initially formed. Their fragmentation behaviour is evidenced in fast metastable fragmentation characteristics and agrees well with an electron capture dissociation mechanism and the enthalpy transfer upon neutralization forms the rationale for the prominent fragmentation and intense chemical noise accompanying successful MALDI. Within the course of the paper, cross-correlations with other desorption/ionization techniques and with earlier discussions on their mechanisms are drawn. Copyright 2000 John Wiley & Sons, Ltd.

  3. Timeline (Bioavailability) of Magnesium Compounds in Hours: Which Magnesium Compound Works Best?

    Science.gov (United States)

    Uysal, Nazan; Kizildag, Servet; Yuce, Zeynep; Guvendi, Guven; Kandis, Sevim; Koc, Basar; Karakilic, Aslı; Camsari, Ulas M; Ates, Mehmet

    2018-04-21

    Magnesium is an element of great importance functioning because of its association with many cellular physiological functions. The magnesium content of foods is gradually decreasing due to food processing, and magnesium supplementation for healthy living has become increasingly popular. However, data is very limited on the bioavailability of various magnesium preparations. The aim of this study is to investigate the bioavailability of five different magnesium compounds (magnesium sulfate, magnesium oxide, magnesium acetyl taurate, magnesium citrate, and magnesium malate) in different tissues. Following a single dose 400 mg/70 kg magnesium administration to Sprague Dawley rats, bioavailability was evaluated by examining time-dependent absorption, tissue penetration, and the effects on the behavior of the animals. Pharmacokinetically, the area under the curve calculation is highest in the magnesium malate. The magnesium acetyl taurate was found to have the second highest area under the curve calculation. Magnesium acetyl taurate was rapidly absorbed, able to pass through to the brain easily, had the highest tissue concentration level in the brain, and was found to be associated with decreased anxiety indicators. Magnesium malate levels remained high for an extended period of time in the serum. The commonly prescribed dietary supplements magnesium oxide and magnesium citrate had the lowest bioavailability when compared to our control group. More research is needed to investigate the bioavailability of magnesium malate and acetyl taurate compounds and their effects in specific tissues and on behavior.

  4. Time delay between singly and doubly ionizing wavepackets in laser-driven helium

    International Nuclear Information System (INIS)

    Parker, J S; Doherty, B J S; Meharg, K J; Taylor, K T

    2003-01-01

    We present calculations of the time delay between single and double ionization of helium, obtained from full-dimensionality numerical integrations of the helium-laser Schroedinger equation. The notion of a quantum mechanical time delay is defined in terms of the interval between correlated bursts of single and double ionization. Calculations are performed at 390 and 780 nm in laser intensities that range from 2 x 10 14 to 14 x 10 14 Wcm -2 . We find results consistent with the rescattering model of double ionization but supporting its classical interpretation only at 780 nm. (letter to the editor)

  5. Ferroelectric lead magnesium niobate-lead titanate single crystals for ultrasonic hydrophone applications

    International Nuclear Information System (INIS)

    Lau, S.T.; Lam, K.H.; Chan, H.L.W.; Choy, C.L.; Luo, H.S.; Yin, Q.R.; Yin, Z.W.

    2004-01-01

    Ferroelectric lead magnesium niobate-lead titanate (PMN-PT) single crystals with a composition around the rhombohedral-tetragonal morphotropic phase boundary (65 mol% of PMN) were used to fabricate single-element needle-type hydrophones for measuring the spatial and temporal characteristics of medical ultrasonic transducers. PMN-PT single crystal was grown by a modified Bridgman method. Discs (0.5 mm thick) with normal along the direction were cut and then poled by a dc field in the thickness direction. The single crystal has a high relative permittivity (ε r ∼4000) making it appropriate for small area hydrophone applications. Single-element needle-type hydrophones with this material as the sensing element have been fabricated and characterized. The hydrophones have flat frequency response and good receiving sensitivity over certain frequency range in the megahertz region

  6. Spider silk as a template for obtaining magnesium oxide and magnesium hydroxide fibers

    Directory of Open Access Journals (Sweden)

    Dmitrović Svetlana

    2018-01-01

    Full Text Available Spider silk fibers, collected from Pholcus Phalangioides spider were used as a template for obtaining magnesium oxide (MgO, periclase as well as magnesium hydroxide (Mg(OH2, brucite fibers. Magnesium oxide fibers were obtained in a simple manner by heat induced decomposition of magnesium salt (MgCl2 in the presence of the spider silk fibers, while magnesium hydroxide fibers were synthesized by hydration of MgO fibers at 50, 70 and 90 C, for 48 and 96 h. According to Scanning electron microscopy (SEM, dimensions of spider silk fibers determined the dimension of synthesized MgO fibers, while for Mg(OH2 fibers, the average diameter was increased with prolonging the hydration period. The surface of Mg(OH2 fibers was noticed to be covered with brucite in a form of plates. X-Ray diffraction (XRD analysis showed that MgO fibers were single-phased (the pure magnesium oxide fibers were obtained, while Mg(OH2 fibers were two- or single-phased brucite depending on incubation period, and/or incubation temperature. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 45012

  7. Electron-helium S-wave model benchmark calculations. I. Single ionization and single excitation

    Science.gov (United States)

    Bartlett, Philip L.; Stelbovics, Andris T.

    2010-02-01

    A full four-body implementation of the propagating exterior complex scaling (PECS) method [J. Phys. B 37, L69 (2004)] is developed and applied to the electron-impact of helium in an S-wave model. Time-independent solutions to the Schrödinger equation are found numerically in coordinate space over a wide range of energies and used to evaluate total and differential cross sections for a complete set of three- and four-body processes with benchmark precision. With this model we demonstrate the suitability of the PECS method for the complete solution of the full electron-helium system. Here we detail the theoretical and computational development of the four-body PECS method and present results for three-body channels: single excitation and single ionization. Four-body cross sections are presented in the sequel to this article [Phys. Rev. A 81, 022716 (2010)]. The calculations reveal structure in the total and energy-differential single-ionization cross sections for excited-state targets that is due to interference from autoionization channels and is evident over a wide range of incident electron energies.

  8. Decrease in Ionized and Total Magnesium Blood Concentrations in Endurance Athletes Following an Exercise Bout Restores within Hours-Potential Consequences for Monitoring and Supplementation.

    Science.gov (United States)

    Terink, Rieneke; Balvers, Michiel G J; Hopman, Maria T; Witkamp, Renger F; Mensink, Marco; Gunnewiek, Jacqueline M T Klein

    2017-06-01

    Magnesium is essential for optimal sport performance, generating an interest to monitor its status in athletes. However, before measuring magnesium status in blood could become routine, more insight into its diurnal fluctuations and effects of exercise itself is necessary. Therefore, we measured the effect of an acute bout of exercise on ionized (iMg) and total plasma magnesium (tMg) in blood obtained from 18 healthy well-trained endurance athletes (age, 31.1 ± 8.1 yr.; VO 2max , 50.9 ± 7.5 ml/kg/min) at multiple time points, and compared this with a resting situation. At both days, 7 blood samples were taken at set time points (8:30 fasted, 11:00, 12:30, 13:30, 15:00, 16:00, 18:30). The control day was included to correct for a putative diurnal fluctuation of magnesium. During the exercise day, athletes performed a 90 min bicycle ergometer test (70% VO 2max ) between 11:00 and 12:30. Whole blood samples were analyzed for iMg and plasma for tMg concentrations. Both concentrations decreased significantly after exercise (0.52 ± 0.04-0.45 ± 0.03 mmol/L and 0.81 ± 0.07-0.73 ± 0.06 mmol/L, respectively, p exercise. These findings suggest that timing of blood sampling to analyze Mg status is important. Additional research is needed to establish the recovery time after different types of exercise to come to a general advice regarding the timing of magnesium status assessment in practice.

  9. Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer

    Directory of Open Access Journals (Sweden)

    Yunguang Huang

    2015-01-01

    Full Text Available A vacuum ultraviolet lamp based single photon ionization- (SPI- photoelectron ionization (PEI portable reflecting time-of-flight mass spectrometer (TOFMS was designed for online monitoring gas samples. It has a dual mode ionization source: SPI for analyte with ionization energy (IE below 10.6 eV and PEI for IE higher than 10.6 eV. Two kinds of sampling inlets, a capillary inlet and a membrane inlet, are utilized for high concentration and trace volatile organic compounds, respectively. A mass resolution of 1100 at m/z 64 has been obtained with a total size of 40 × 31 × 29 cm, the weight is 27 kg, and the power consumption is only 70 W. A mixture of benzene, toluene, and xylene (BTX, SO2, and discharging products of SF6 were used to test its performance, and the result showed that the limit of quantitation for BTX is as low as 5 ppbv (S/N = 10 : 1 with linear dynamic ranges greater than four orders of magnitude. The portable TOFMS was also evaluated by analyzing volatile organic compounds from wine and decomposition products of SF6 inside of a gas-insulated switchgear.

  10. Ionization and single electron capture in collision of highly charged Ar16+ ions with helium

    International Nuclear Information System (INIS)

    Wang Fei; Gou Bingcong

    2008-01-01

    This paper uses the two-centre atomic orbital close-coupling method to study the ionization and the single electron capture in collision of highly charged Ar 16+ ions with He atoms in the velocity range of 1.2–1.9 a.u. The relative importance of single ionization (SI) to single capture (SC) is explored. The comparison between the calculation and experimental data shows that the SI/SC cross section ratios from this work are in good agreement with experimental data. The total single electron ionization cross sections and the total single electron capture cross sections are also given for this collision. The investigation of the partial electron capture cross section shows a general tendency of capture to larger n and l with increasing velocity from 1.2 to 1.9 a.u

  11. The Importance of Magnesium in the Human Body: A Systematic Literature Review.

    Science.gov (United States)

    Glasdam, Sidsel-Marie; Glasdam, Stinne; Peters, Günther H

    2016-01-01

    Magnesium, the second and fourth most abundant cation in the intracellular compartment and whole body, respectively, is of great physiologic importance. Magnesium exists as bound and free ionized forms depending on temperature, pH, ionic strength, and competing ions. Free magnesium participates in many biochemical processes and is most commonly measured by ion-selective electrode. This analytical approach is problematic because complete selectivity is not possible due to competition with other ions, i.e., calcium, and pH interference. Unfortunately, many studies have focused on measurement of total magnesium rather than its free bioactive form making it difficult to correlate to disease states. This systematic literature review presents current analytical challenges in obtaining accurate and reproducible test results for magnesium. © 2016 Elsevier Inc. All rights reserved.

  12. Optical emission studies of atomic and ionic species in the ionized sputter-deposition process of magnesium oxide thin films

    International Nuclear Information System (INIS)

    Matsuda, Y.; Koyama, Y.; Iwaya, M.; Shinohara, M.; Fujiyama, H.

    2005-01-01

    Planar magnetron (PM) power and ICP-RF power dependences of the optical emission intensities of excited atomic and ionic species in the reactive ionized sputter-deposition of magnesium oxide (MgO) thin films were investigated. With the increase in PM power at constant ICP-RF power, Mg I emission intensity increased and Ar I emission intensity gradually decreased. With the increase in ICP-RF power at constant PM power, the Mg I emission intensity increased at lower ICP-RF power and then gradually decreased at higher ICP-RF power; on the contrary, Ar I emission intensity monotonically increased. Emission intensity of atomic oxygen was negligibly small compared with those of Mg I and Ar I under the metallic sputtering mode condition

  13. All-solid-state deep ultraviolet laser for single-photon ionization mass spectrometry.

    Science.gov (United States)

    Yuan, Chengqian; Liu, Xianhu; Zeng, Chenghui; Zhang, Hanyu; Jia, Meiye; Wu, Yishi; Luo, Zhixun; Fu, Hongbing; Yao, Jiannian

    2016-02-01

    We report here the development of a reflectron time-of-flight mass spectrometer utilizing single-photon ionization based on an all-solid-state deep ultraviolet (DUV) laser system. The DUV laser was achieved from the second harmonic generation using a novel nonlinear optical crystal KBe2BO3F2 under the condition of high-purity N2 purging. The unique property of this laser system (177.3-nm wavelength, 15.5-ps pulse duration, and small pulse energy at ∼15 μJ) bears a transient low power density but a high single-photon energy up to 7 eV, allowing for ionization of chemicals, especially organic compounds free of fragmentation. Taking this advantage, we have designed both pulsed nanospray and thermal evaporation sources to form supersonic expansion molecular beams for DUV single-photon ionization mass spectrometry (DUV-SPI-MS). Several aromatic amine compounds have been tested revealing the fragmentation-free performance of the DUV-SPI-MS instrument, enabling applications to identify chemicals from an unknown mixture.

  14. Excitation mechanisms in singly ionized krypton laser

    International Nuclear Information System (INIS)

    El-Sherbini, Th.M.

    1982-01-01

    Lifetimes for the low lying 4p 4 4d and 4p 4 5s levels of singly ionized krypton laser are calculated, taking into account configuration interaction effects. The results show that some of these levels are metastable. They also suggest a two step excitation from the ground state of the ion (or the atom) to the upper 4p 4 5p laser levels involving some intermediate metastable states as a possible excitation mechanism. (author)

  15. Formation of molecules in interstellar clouds from singly and multiply ionized atoms

    International Nuclear Information System (INIS)

    Langer, W.D.; and NASA, Institute for Space Studies, Goddard Space Flight Center, New York)

    1978-01-01

    Soft X-ray and cosmic rays produce multiply ionized atoms which may initiate molecule production in interstellar clouds. This molecule production can occur via ion-molecule reactions with H 2 , either directly from the multiply ionized atom (e.g.,C ++ + H 2 →CH + + H + ), or indirectly from the singly ionized atoms (e.g., N + + H 2 →NH + + H) that are formed from the recombination or charge transfer of the highly ionized atom (e.g., N ++ + e→N + + hv). We investigate the contribution of these reactions to the abundances of carbon-, nitrogen-, and oxygen-bearing molecules in isobaric models of diffuse clouds. In the presence of the average flux estimated for the diffuse soft X-ray background, multiply ionized atoms contribute only minimally (a few percent) to carbon-bearing molecules such as CH. In the neighborhood of diffuse structures or discrete sources, however, where the X-ray flux is enhanced, multiple ionization is considerably more important for molecule production

  16. "Changes in cartilage of rats after treatment with Quinolone and in Magnesium-deficient diet "

    Directory of Open Access Journals (Sweden)

    Shakibaei M

    2002-07-01

    Full Text Available Ultrastructural changes in immature articular carilage were studied after treatment of 5-weeks-old rats with ofloxacin, a fluoroquinolone, and in magnesium deficiency.We concluded that quinolone-induced arthropathy is probably due to chelation of functionally available magnesium in joint cartilage as magnesium deficiency in joint cartilage could impair chondrocyte-matrix- interaction which is mediated by cation-dependent integrin-receptors of the β1-subfamily. With immuno-histochemical methods using monoclonal and polyclonal antibodies we showed that B1 integrins were expressed in rat joint cartilage. Joint cartilage lesions were detected in ofloxacin-treated and magnesium-deficient rats. Lesions were more pronounced in the quinolone-treated group. Expression of several integrins was reduced in the vicinity of lesions after oral treatment with 2×600 mg ofloxacin/kg body wt for one day. Gross-structural lesions (e.g. cleft formation, unmasked collagen fibres in magnesium deficient rats were very similar but changes in intergrin expression were less pronounced. Alterations observed on the ultrastructural level showed striking similarities in magnesium-deficient rats and in rats treated with single doses of 600 mg ofloxacin per kg body wt.Typical observation were: bundle shaped, electron-dense aggregates on the surface and in the cytoplasm of chondrocytes, detachement of the cell membrance from the matrix and necrotic chondrocytes, reduced synthesis and/or reduced of extracellular matrix and swelling of cell organelles such as mitochondria.The results of this study confirm our previously reported finding that quinolone-induced arthropathy probably is caued by a reduction of functionally available magnesium (ionized Mg2+ in cartilage. Furthermore, they provide a basis for aimed studies with human cartilage samples from quinolone-treated patients which might be available postmortal or after hip replacement surgery

  17. Large single-crystal diamond substrates for ionizing radiation detection

    Energy Technology Data Exchange (ETDEWEB)

    Girolami, Marco; Bellucci, Alessandro; Calvani, Paolo; Trucchi, Daniele M. [Istituto di Struttura della Materia (ISM), Consiglio Nazionale delle Ricerche (CNR), Sede Secondaria di Montelibretti, Monterotondo Stazione, Roma (Italy)

    2016-10-15

    The need for large active volume detectors for ionizing radiations and particles, with both large area and thickness, is becoming more and more compelling in a wide range of applications, spanning from X-ray dosimetry to neutron spectroscopy. Recently, 8.0 x 8.0 mm{sup 2} wide and 1.2 mm thick single-crystal diamond plates have been put on the market, representing a first step to the fabrication of large area monolithic diamond detectors with optimized charge transport properties, obtainable up to now only with smaller samples. The more-than-double thickness, if compared to standard plates (typically 500 μm thick), demonstrated to be effective in improving the detector response to highly penetrating ionizing radiations, such as γ-rays. Here we report on the first measurements performed on large active volume single-crystal diamond plates, both in the dark and under irradiation with optical wavelengths (190-1100 nm), X-rays, and radioactive γ-emitting sources ({sup 57}Co and {sup 22}Na). (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. The spectrum of singly ionized oxygen, O II

    International Nuclear Information System (INIS)

    Wenaker, I.

    1990-01-01

    The spectrum of singly ionized oxygen, O II, emitted by a spark-generated, electrodeless discharge light source, has been investigated in the wavelength range 2100-11700 A. About 740 lines, 359 of which have not been reported earlier, were measured. As a result the energies of about 50 new levels have been determined, and the O II term system now presented includes 254 levels. The quartet system is firmly connected to the doublet system by 56 identified intersystem lines. The ionization limits have been determined by applying the polarization formula to the 4f, 5f, 5g and 6g levels. The experimentally determined value for the lowest limit, 2s 2 2p 2 3 P 0 , is 283270.9±0.5 cm -1 above the 2s 2 2p 3 4 S 3/2 ground state. (orig.)

  19. Double and single ionization of He and H2 by slow protons and antiprotons

    International Nuclear Information System (INIS)

    Kimura, Mineo

    1994-01-01

    Double and single ionization of He and H 2 by proton (p) and antiproton (bar p)impact in the energy region below 50 keV was studied theoretically by using the semiclassical molecular picture. As the energy decreased, the ratio of the double- to the single-ionization cross section increased for impact and decreased for p impact for both He and H 2 . These trends are consistent with recent measurements for He. Ionization mechanisms differ distinctly for p impact and bar p impact. For p impact, the dominant mechanism for double ionization at the lower energies is sequential ladder climbing by the two electrons through various excited channels and finally into the continuum. For bar p impact, in contrast, the approaching negative charge distorts both the He and H 2 electron clouds toward the other side of the nucleus and decreases the electron binding energies. These effects enhance electron-electron interactions, increasing double ionization. For the H 2 , an effect of molecular orientation is an additional complication in determining the dynamics

  20. Momentum spectra for single and double electron ionization of He in relativistic collisions

    International Nuclear Information System (INIS)

    Wood, C.J.; Olson, R.E.

    1997-08-01

    The complete momentum spectra for single and double ionization of He by 1GeV/u (β=0.88) U 92+ have been investigated using a classical trajectory Monte Carlo method corrected for the relativistic projectile. The 1/r 12 electron-electron interaction has been included in the post-collision region for double ionization to incorporate the effects of both the nuclear-electron and electron-electron ionizing interactions, and to access the effects of electron correlation in the electron spectra. Experimental measurements were able to determine the longitudinal momentum spectra for single ionization; these observations are in accordance with the theoretical predictions for the three-body momentum balance between projectile, recoil ion, and ionized electron. In particular, the Lorentz contraction of the Coulomb interaction of the projectile manifests itself in the decrease of the post-collision interaction of the projectile with the electron and recoil ion, causing them to recoil back-to-back as in the case for a short electromagnetic pulse. This feature is clearly displayed in both the theoretical and experimental longitudinal momentum spectra, and by comparing to calculations that are performed at the same collision speed but do not include the relativistic potentials. Moreover, collision plane spectra of the three particles demonstrate that the momenta of the recoil ion and ionized electron are preferentially equal, and opposite, to each other. The electron spectra for double ionization show that the inclusion of the electron-electron interaction in the post-collision regime partitions the combined ionization momentum of the electrons so that the electrons are preferentially emitted in opposite azimuthal angles to one another. This is in contrast to calculations made assuming independent electrons. (orig.)

  1. Detection of single atoms by resonance ionization spectroscopy

    International Nuclear Information System (INIS)

    Hurst, G.S.

    1986-01-01

    Rutherford's idea for counting individual atoms can, in principle, be implemented for nearly any type of atom, whether stable or radioactive, by using methods of resonance ionization. With the RIS technique, a laser is tuned to a wavelength which will promote a valence electron in a Z-selected atom to an excited level. Additional resonance or nonresonance photoabsorption steps are used to achieve nearly 100% ionization efficiencies. Hence, the RIS process can be saturated for the Z-selected atoms; and since detectors are available for counting either single electrons or positive ions, one-atom detection is possible. Some examples are given of one-atom detection, including that of the noble gases, in order to show complementarity with AMS methods. For instance, the detection of 81 Kr using RIS has interesting applications for solar neutrino research, ice-cap dating, and groundwater dating. 39 refs., 7 figs., 2 tabs

  2. Momentum spectra for single and double electron ionization of He in relativistic collisions

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    The complete momentum spectra for single and double ionization of He by 1-GeV/u (β=0.88) U 92+ have been investigated using a classical trajectory Monte Carlo method corrected for the relativistic projectile. The 1/r 12 electron-electron interaction has been included in the post-collision region for double ionization to incorporate the effects of both the nuclear-electron and electron-electron ionizing interactions, and to access the effects of electron correlation in the electron spectra. Experimental measurements were able to determine the longitudinal momentum spectra for single ionization; these observations are in accordance with the theoretical predictions for the three-body momentum balance between projectile, recoil ion, and ionized electron. In particular, the Lorentz contraction of the Coulomb interaction of the projectile manifests itself in the decrease of the post-collision interaction of the projectile with the electron and recoil ion, causing them to recoil back-to-back as in the case for a short electromagnetic pulse. This feature is clearly displayed in both the theoretical and experimental longitudinal momentum spectra, and by comparing to calculations that are performed at the same collision speed but do not include the relativistic potentials. Moreover, collision plane spectra of the three particles demonstrate that the momenta of the recoil ion and ionized electron are preferentially equal, and opposite, to each other. The electron spectra for double ionization show that the inclusion of the electron-electron interaction in the post-collision regime partitions the combined ionization momentum of the electrons so that the electrons are preferentially emitted in opposite azimuthal angles to one another. This is in contrast to calculations made assuming independent electrons. copyright 1997 The American Physical Society

  3. The Effects of High Level Magnesium Dialysis/Substitution Fluid on Magnesium Homeostasis under Regional Citrate Anticoagulation in Critically Ill.

    Directory of Open Access Journals (Sweden)

    Mychajlo Zakharchenko

    Full Text Available The requirements for magnesium (Mg supplementation increase under regional citrate anticoagulation (RCA because citrate acts by chelation of bivalent cations within the blood circuit. The level of magnesium in commercially available fluids for continuous renal replacement therapy (CRRT may not be sufficient to prevent hypomagnesemia.Patients (n = 45 on CRRT (2,000 ml/h, blood flow (Qb 100 ml/min with RCA modality (4% trisodium citrate using calcium free fluid with 0.75 mmol/l of Mg with additional magnesium substitution were observed after switch to the calcium-free fluid with magnesium concentration of 1.50 mmol/l (n = 42 and no extra magnesium replenishment. All patients had renal indications for CRRT, were treated with the same devices, filters and the same postfilter ionized calcium endpoint (<0.4 mmol/l of prefilter citrate dosage. Under the high level Mg fluid the Qb, dosages of citrate and CRRT were consequently escalated in 9h steps to test various settings.Median balance of Mg was -0.91 (-1.18 to -0.53 mmol/h with Mg 0.75 mmol/l and 0.2 (0.06-0.35 mmol/h when fluid with Mg 1.50 mmol/l was used. It was close to zero (0.02 (-0.12-0.18 mmol/h with higher blood flow and dosage of citrate, increased again to 0.15 (-0.11-0.25 mmol/h with 3,000 ml/h of high magnesium containing fluid (p<0.001. The arterial levels of Mg were mildly increased after the change for high level magnesium containing fluid (p<0.01.Compared to ordinary dialysis fluid the mildly hypermagnesemic fluid provided even balances and adequate levels within ordinary configurations of CRRT with RCA and without a need for extra magnesium replenishment.ClinicalTrials.gov Identifier: NCT01361581.

  4. Single-photon double and triple ionization of acetaldehyde (ethanal) studied by multi-electron coincidence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zagorodskikh, S. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Department of Physics, University of Gothenburg, Origovägen 6B, SE-412 96 Gothenburg (Sweden); Zhaunerchyk, V. [Department of Physics, University of Gothenburg, Origovägen 6B, SE-412 96 Gothenburg (Sweden); Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Mucke, M. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Eland, J.H.D. [Department of Chemistry, Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ (United Kingdom); Department of Physics, University of Gothenburg, Origovägen 6B, SE-412 96 Gothenburg (Sweden); Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Squibb, R.J. [Department of Physics, University of Gothenburg, Origovägen 6B, SE-412 96 Gothenburg (Sweden); Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Karlsson, L. [Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden); Linusson, P. [Department of Physics, Stockholm University, AlbaNova University Center, SE-106 91 Stockholm (Sweden); Feifel, R., E-mail: raimund.feifel@gu.se [Department of Physics, University of Gothenburg, Origovägen 6B, SE-412 96 Gothenburg (Sweden); Department of Physics and Astronomy, Uppsala University, Box 516, SE-751 20 Uppsala (Sweden)

    2015-12-16

    Highlights: • The first ever valence double ionization spectrum of acetaldehyde is reported. • The first ever site-selectively extracted Auger spectra of acetaldehyde are reported. • The first ever Auger spectra of acetaldehyde involving shake-up states are reported. • The first ever triple ionization spectra of acetaldehyde are reported. • The first ever energy sharing of electron pairs emitted by acetaldehyde is presented. - Abstract: Single-photon multiple ionization processes of acetaldehyde (ethanal) have been experimentally investigated by utilizing a multi-particle coincidence technique based on the time-of-flight magnetic bottle principle, in combination with either a synchrotron radiation source or a pulsed helium discharge lamp. The processes investigated include double and triple ionization in the valence region as well as single and double Auger decay of core-ionized acetaldehyde. The latter are studied site-selectively for chemically different carbon core vacancies, scrutinizing early theoretical predictions specifically made for the case of acetaldehyde. Moreover, Auger processes in shake-up and core-valence ionized states are investigated. In the cases where the processes involve simultaneous emission of two electrons, the distributions of the energy sharing are presented, emphasizing either the knock-out or shake-off mechanism.

  5. Doubly differential single and multiple ionization of krypton by electron impact

    International Nuclear Information System (INIS)

    Lucio, O. G. de; Gavin, J.; DuBois, R. D.

    2007-01-01

    Differential measurements for single and multiple ionization of Kr by 240 and 500 eV electron impact are presented. Using a pulsed extraction field, Kr + , Kr 2+ , and Kr 3+ ions were measured in coincidence with scattered electrons for energy losses up to 120 eV and scattering angles between 16 degree sign and 90 degree sign . Scaling properties of the doubly differential cross sections (DDCS) are investigated as a function of energy loss, scattering angle, and momentum transfer. It is shown that scaling the DDCS as outlined by Kim and Inokuti and plotting them versus a parameter consisting of the momentum transfer divided by the square root of the impact energy times 1-cos(θ), where θ is the scattering angle, yielded similar curves, but with different magnitudes, for single and multiple ionization. Normalizing these curves together produced two universal curves, one appropriate for single and multiple electron emission at larger scattering angles (θ≥30 degree sign ) and one appropriate for small scattering angles (θ<30 degree sign )

  6. Bond rearrangement caused by sudden single and multiple ionization of water molecules

    International Nuclear Information System (INIS)

    Ben-Itzhak, I.; Sayler, A. Max; Leonard, M.; Maseberg, J.W.; Hathiramani, D.; Wells, E.; Smith, M.A.; Xia, Jiangfan; Wang, Pengqian; Carnes, K.D.; Esry, B.D.

    2005-01-01

    Bond rearrangement, namely the dissociation of water into H 2 + +O q+ following ionization by fast proton and highly charged ion impact, was investigated. Single ionization by fast proton impact exhibits a strong isotopic effect, the dissociation of H 2 O + ->H 2 + +O being about twice as likely as D 2 O + ->D 2 + +O, with HDO + ->HD + +O in between. This suggests that the bond rearrangement does not happen during the slow dissociation, but rather during the very fast ionization, and thus H 2 + should also be produced when the water molecule is multiply ionized. We observed that the H 2 + +O + and H 2 + +O 2+ production in 1MeV/amu F 7+ +H 2 O collisions are 0.209+/-0.006% and 0.0665+/-0.003%, respectively, of the main double-ionization dissociation product, H 2 O 2+ ->H + +OH + . This ratio is similar to the triple to double ionization ratio in similar collisions with atomic targets thus suggesting that the bond-rearrangement fraction out of each ionization level is approximately constant. Similar dissociation channels in the heavier water isotopes, which are expected to be smaller, are under study. Finally, the fragmentation of HDO exhibits very strong isotopic preference for breaking the OH bond over the OD bond

  7. One- and two-photon single ionization of 1D helium: resolving the role of individual decay channels and resonance states

    Energy Technology Data Exchange (ETDEWEB)

    Neimanns, Vera; Zimmermann, Klaus; Joerder, Felix; Buchleitner, Andreas [Albert-Ludwigs-Univ., Freiburg im Breisgau (Germany). Quantum Optics and Statistics; Lugan, Pierre [Laboratory of Theoretical Physics of Nanosystems, Institute of Theoretical Physics, EPF Lausanne (Switzerland)

    2012-07-01

    We combine the method of complex rotation and Floquet theory to analyze the multiphoton ionization of helium atoms in strong laser fields. We focus on 1D Z{sup 2+}e{sup -}e{sup -} helium to highlight the methods that allow us to extract the partial decay rates associated with various decay channels. In the regime of one-photon single ionization, we study the dependence of the partial rates associated with the singly ionized He{sup +}(N) states on the field frequency. We show that the electron-electron interaction provides couplings to higher single-ionization continua. Finally, we examine two-photon single-ionization processes, and analyze the role of the internal electronic structure of the atom, specifically the signature of resonant coupling to intermediate bound states on the decay rates.

  8. Giant plasmon excitation in single and double ionization of C60 by fast highly charged Si and O ions

    International Nuclear Information System (INIS)

    Kelkar, A H; Kadhane, U; Misra, D; Tribedi, L C

    2007-01-01

    Se have investigated single and double ionization of C 60 molecule in collisions with 2.33 MeV/u Si q+ (q=6-14) and 3.125 MeV/u O q+ (q=5-8) projectiles. The projectile charge state dependence of the single and double ionization yields of C 60 are then compared to those for an ion-atom collision system using Ne gas as a target. A large difference between the gas and the cluster target behaviour was partially explained in terms of a model based on collective excitation namely the giant dipole plasmon resonance (GDPR). The qualitative agreement between the data and GDPR model prediction for single and double ionization signifies the importance of single and double plasmon excitations in the ionization process. A large deviation of the GDPR model for triple and quadruple ionization from the experimental data imply the importance of the other low impact parameter processes such as evaporation, fragmentation and a possible solid-like dynamical screening

  9. Preparation and corrosion resistance of magnesium phytic acid/hydroxyapatite composite coatings on biodegradable AZ31 magnesium alloy.

    Science.gov (United States)

    Zhang, Min; Cai, Shu; Zhang, Feiyang; Xu, Guohua; Wang, Fengwu; Yu, Nian; Wu, Xiaodong

    2017-06-01

    In this work, a magnesium phytic acid/hydroxyapatite composite coating was successfully prepared on AZ31 magnesium alloy substrate by chemical conversion deposition technology with the aim of improving its corrosion resistance and bioactivity. The influence of hydroxyapatite (HA) content on the microstructure and corrosion resistance of the coatings was investigated. The results showed that with the increase of HA content in phytic acid solution, the cracks on the surface of the coatings gradually reduced, which subsequently improved the corrosion resistance of these coated magnesium alloy. Electrochemical measurements in simulated body fluid (SBF) revealed that the composite coating with 45 wt.% HA addition exhibited superior surface integrity and significantly improved corrosion resistance compared with the single phytic acid conversion coating. The results of the immersion test in SBF showed that the composite coating could provide more effective protection for magnesium alloy substrate than that of the single phytic acid coating and showed good bioactivity. Magnesium phytic acid/hydroxyapatite composite, with the desired bioactivity, can be synthesized through chemical conversion deposition technology as protective coatings for surface modification of the biodegradable magnesium alloy implants. The design idea of the new type of biomaterial is belong to the concept of "third generation biomaterial". Corrosion behavior and bioactivity of coated magnesium alloy are the key issues during implantation. In this study, preparation and corrosion behavior of magnesium phytic acid/hydroxyapatite composite coatings on magnesium alloy were studied. The basic findings and significance of this paper are as follows: 1. A novel environmentally friendly, homogenous and crack-free magnesium phytic acid/hydroxyapatite composite coating was fabricated on AZ31 magnesium alloy via chemical conversion deposition technology with the aim of enhancing its corrosion resistance and

  10. Electron-helium S-wave model benchmark calculations. II. Double ionization, single ionization with excitation, and double excitation

    Science.gov (United States)

    Bartlett, Philip L.; Stelbovics, Andris T.

    2010-02-01

    The propagating exterior complex scaling (PECS) method is extended to all four-body processes in electron impact on helium in an S-wave model. Total and energy-differential cross sections are presented with benchmark accuracy for double ionization, single ionization with excitation, and double excitation (to autoionizing states) for incident-electron energies from threshold to 500 eV. While the PECS three-body cross sections for this model given in the preceding article [Phys. Rev. A 81, 022715 (2010)] are in good agreement with other methods, there are considerable discrepancies for these four-body processes. With this model we demonstrate the suitability of the PECS method for the complete solution of the electron-helium system.

  11. Auger transitions in singly and multiply ionized atoms

    International Nuclear Information System (INIS)

    Mehlhorn, W.

    1978-01-01

    Some recent progress in Auger and autoionizing electron spectrometry of free metal atoms and of multiply ionized atoms is reviewed. The differences which arise between the spectra of atoms in the gaseous and the solid state are due to solid state effects. This will be shown for Cd as an example. The super Coster-Kronig transitions 3p-3d 2 (hole notation) and Coster-Kronig transitions 3p-3d 4s have been measured and compared with free-atom calculations for free Zn atoms. The experimental width GAMMA(3p)=(2.1+-0.2)eV found for the free atom agrees with the value obtained for solid Zn but is considerably smaller than the theoretical value for the free atom. Autoionizing spectra of Na following an L-shell excitation or ionization by different particles are compared and discussed. The nonisotropic angular distribution of electrons from the transition 2p 5 3s 2 2 Psub(3/2)→2p 6 +e - is compared with theoretical calculations. Two examples for Auger spectrometry of multiply ionized atoms are given: (1) excitation of neon target atoms by light and heavy ions, and (2) excitation of projectile ions Be + and B + in single gas collisions with CH 4 . A strong alignment of the excited atoms has also been found here

  12. Toward single-cell analysis by plume collimation in laser ablation electrospray ionization mass spectrometry.

    Science.gov (United States)

    Stolee, Jessica A; Vertes, Akos

    2013-04-02

    Ambient ionization methods for mass spectrometry have enabled the in situ and in vivo analysis of biological tissues and cells. When an etched optical fiber is used to deliver laser energy to a sample in laser ablation electrospray ionization (LAESI) mass spectrometry, the analysis of large single cells becomes possible. However, because in this arrangement the ablation plume expands in three dimensions, only a small portion of it is ionized by the electrospray. Here we show that sample ablation within a capillary helps to confine the radial expansion of the plume. Plume collimation, due to the altered expansion dynamics, leads to greater interaction with the electrospray plume resulting in increased ionization efficiency, reduced limit of detection (by a factor of ~13, reaching 600 amol for verapamil), and extended dynamic range (6 orders of magnitude) compared to conventional LAESI. This enhanced sensitivity enables the analysis of a range of metabolites from small cell populations and single cells in the ambient environment. This technique has the potential to be integrated with flow cytometry for high-throughput metabolite analysis of sorted cells.

  13. Magnesium, magnesium alloys, and magnesium composites

    National Research Council Canada - National Science Library

    Gupta, M; Sharon, Nai Mui Ling

    2011-01-01

    "Properties of Magnesium Composites for Material Scientists, Engineers and Selectors is the first book-length reference to provide an insight into current and future magnesium-based materials in terms...

  14. Polarization effects in above-threshold ionization with a mid-infrared strong laser field

    Science.gov (United States)

    Kang, Hui-Peng; Xu, Song-Po; Wang, Yan-Lan; Yu, Shao-Gang; Zhao, Xiao-Yun; Hao, Xiao-Lei; Lai, Xuan-Yang; Pfeifer, Thomas; Liu, Xiao-Jun; Chen, Jing; Cheng, Ya; Xu, Zhi-Zhan

    2018-05-01

    Using a semiclassical approach, we theoretically study the above-threshold ionization of magnesium by intense, mid-infrared laser pulses. The formation of low-energy structures in the photoelectron spectrum is found to be enhanced by comparing with a calculation based on the single-active electron approximation. By performing electron trajectory and recollision-time distribution analysis, we demonstrate that this phenomenon is due to the laser-induced ionic core polarization effects on the recolliding electrons. We also show that the polarization effects should be experimentally detectable. Our finding provides new insight into ultrafast control of strong-field photoionization and imaging of polar molecules.

  15. Single Photon Double Ionization of Atomic Oxygen

    Science.gov (United States)

    Wickramarathna, Madhushani; Gorczyca, Thomas; Ballance, Connor; Stolte, Wayne

    2017-04-01

    Single photon double ionization cross sections are calculated using an R-matrix with pseudostates (RMPS) method which was recently applied by Gorczyca et al. for the double photoionization of helium. With the convergence of these theoretical calculations for the simple case of helium, we extend this methodology to consider the more complex case of oxygen double photoionization. We compare our calculated results with recent measurements at the Advanced Light Source, as well as earlier experimental measurements. Our RMPS results agree well, qualitatively, with the experimental measurements, but there exist outstanding discrepancies to be addressed. This project is supported by NASA APRA award NNX17AD41G.

  16. Ratios of double to single ionization of He and Ne by strong 400-nm laser pulses using the quantitative rescattering theory

    Science.gov (United States)

    Chen, Zhangjin; Li, Xiaojin; Zatsarinny, Oleg; Bartschat, Klaus; Lin, C. D.

    2018-01-01

    We present numerical simulations of the ratio between double and single ionization of He and Ne by intense laser pulses at wavelengths of 390 and 400 nm, respectively. The yields of doubly charged ions due to nonsequential double ionization (NSDI) are obtained by employing the quantitative rescattering (QRS) model. In this model, the NSDI ionization probability is expressed as a product of the returning electron wave packet (RWP) and the total scattering cross sections for laser-free electron impact excitation and electron impact ionization of the parent ion. According to the QRS theory, the same RWP is also responsible for the emission of high-energy above-threshold ionization photoelectrons. To obtain absolute double-ionization yields, the RWP is generated by solving the time-dependent Schrödinger equation (TDSE) within a one-electron model. The same TDSE results can also be taken to obtain single-ionization yields. By using the TDSE results to calibrate single ionization and the RWP obtained from the strong-field approximation, we further simplify the calculation such that the nonuniform laser intensity distribution in the focused laser beam can be accounted for. In addition, laser-free electron impact excitation and ionization cross sections are calculated using the state-of-the-art many-electron R -matrix theory. The simulation results for double-to-single-ionization ratios are found to compare well with experimental data and support the validity of the nonsequential double-ionization mechanism for the covered intensity region.

  17. Magnesium isotope fractionation in cation-exchange chromatography

    International Nuclear Information System (INIS)

    Oi, T.; Yanase, S.; Kakihana, H.

    1987-01-01

    Band displacement chromatography of magnesium has been carried out successfully for the purpose of magnesium isotope separation by using a strongly acidic cation-exchange resin and the strontium ion as the replacement ion. A small but definite accumulation of the heavier isotopes ( 25 Mg, 26 Mg) has been observed at the front parts of the magnesium chromatograms. The heavier isotopes have been fractionated preferentially into the solution phase. The single-stage separation factors have been calculated for the 25 Mg/ 24 Mg and 26 Mg/ 24 isotopic pairs at 25 0 C. The reduced partition function ratios of magnesium species involved in the present study have been estimated

  18. The electron-impact ionization of Ar and Kr revisited: A critical analysis of double-to-single ionization cross section ratio measurements using the fast-atom-beam technique

    International Nuclear Information System (INIS)

    Tarnovsky, V.; Becker, K.

    1992-01-01

    We report new measurements of the absolute electron-impact double ionization cross sections for Ar and Kr and of the ratios of double-to-single ionization for impact energies from threshold to 200 eV using the crossed electron-beam - fast-atom-beam technique. The work was motivated by the recently highlighted spread of about 30% in the Ar 2+ /Ar + ionization cross section ratios obtained by several groups using different experimental techniques. Such a spread is inconsistent with statistical uncertainties of typically 3% or less that were quoted for the various reported ratios. A similar situation exists for Kr where the spread among the recently published Kr 2+ /Kr + ionization cross section ratios is about 15%. We made an attempt to identify all potential systematic errors inherent to the fast-beam technique that could affect the measurement of cross section ratios with special emphasis on those systematic errors that could influence the detection of singly and doubly charged product ions differently. We found Ar 2+ /Ar + and Kr 2+ /Kr + cross section ratios of, respectively 0.066±0.007 and 0.087±0.008 at 100 eV which confirm earlier measurements using the same experimental technique. The error limits on cross sections ratios of multiple-to-single ionization for the same target atom and at least ±10% for ratios of single ionization cross sections for different target species. Our error limits are dominated by systematic uncertainties of the apparatus which do not cancel when cross section ratios are measured, since the ratios are obtained under similar, but not identical experimental conditions. (orig.)

  19. Giant plasmon excitation in single and double ionization of C{sub 60} by fast highly charged Si and O ions

    Energy Technology Data Exchange (ETDEWEB)

    Kelkar, A H; Kadhane, U; Misra, D; Tribedi, L C [Tata Institute of Fundamental Research, Colaba, Mumbai-5 (India)

    2007-09-15

    Se have investigated single and double ionization of C{sub 60} molecule in collisions with 2.33 MeV/u Si{sup q+} (q=6-14) and 3.125 MeV/u O{sup q+} (q=5-8) projectiles. The projectile charge state dependence of the single and double ionization yields of C{sub 60} are then compared to those for an ion-atom collision system using Ne gas as a target. A large difference between the gas and the cluster target behaviour was partially explained in terms of a model based on collective excitation namely the giant dipole plasmon resonance (GDPR). The qualitative agreement between the data and GDPR model prediction for single and double ionization signifies the importance of single and double plasmon excitations in the ionization process. A large deviation of the GDPR model for triple and quadruple ionization from the experimental data imply the importance of the other low impact parameter processes such as evaporation, fragmentation and a possible solid-like dynamical screening.

  20. Magnesium Hall Thruster

    Science.gov (United States)

    Szabo, James J.

    2015-01-01

    This Phase II project is developing a magnesium (Mg) Hall effect thruster system that would open the door for in situ resource utilization (ISRU)-based solar system exploration. Magnesium is light and easy to ionize. For a Mars- Earth transfer, the propellant mass savings with respect to a xenon Hall effect thruster (HET) system are enormous. Magnesium also can be combusted in a rocket with carbon dioxide (CO2) or water (H2O), enabling a multimode propulsion system with propellant sharing and ISRU. In the near term, CO2 and H2O would be collected in situ on Mars or the moon. In the far term, Mg itself would be collected from Martian and lunar regolith. In Phase I, an integrated, medium-power (1- to 3-kW) Mg HET system was developed and tested. Controlled, steady operation at constant voltage and power was demonstrated. Preliminary measurements indicate a specific impulse (Isp) greater than 4,000 s was achieved at a discharge potential of 400 V. The feasibility of delivering fluidized Mg powder to a medium- or high-power thruster also was demonstrated. Phase II of the project evaluated the performance of an integrated, highpower Mg Hall thruster system in a relevant space environment. Researchers improved the medium power thruster system and characterized it in detail. Researchers also designed and built a high-power (8- to 20-kW) Mg HET. A fluidized powder feed system supporting the high-power thruster was built and delivered to Busek Company, Inc.

  1. Single photon core ionization with core excitation: a new spectroscopic tool

    International Nuclear Information System (INIS)

    Penent, F; Carniato, S; Lablanquie, P; Selles, P; Palaudoux, J; Andric, L; Žitnik, M; Bučar, K; Shigemasa, E; Nakano, M; Ito, K; Hikosaka, Y

    2015-01-01

    The simultaneous core ionization and core excitation process (or K -2 V process) induced by absorption of a single photon provides the basis of a new spectroscopy that offers both advantages of X-ray Photoelectron Spectroscopy (XPS) and near-edge x-ray absorption fine structures (NEXAFS) spectroscopy (paper)

  2. Improved forced impulse method calculations of single and double ionization of helium by collision with high-energy protons and antiprotons

    International Nuclear Information System (INIS)

    Ford, A.L.; Reading, J.F.

    1994-01-01

    Our previous forced impulse method calculations of single and double ionization of helium by protons and antiprotons have been improved by including d orbitals in the target centre basis. The calculations are in good agreement with experimental measurements of the ratio R of double to single ionization, without the 1.35 scaling factor we applied to our previous results. We also compare the separate single and double ionization cross sections to experiment and find good agreement. Experimental cross sections differential in projectile scattering angle at large angle (greater than 2.5 mrad) are compared to our impact parameter dependent ionization probabilities at small impact parameter, for the double to single ratio. The agreement is good, except at the lowest energy we have considered, 0.3 eV. (Author)

  3. Effect of multiple plasmon excitation on single, double and multiple ionizations of C{sub 60} in collisions with fast highly charged Si ions

    Energy Technology Data Exchange (ETDEWEB)

    Kelkar, A H; Kadhane, U; Misra, D; Kumar, A; Tribedi, L C [Tata Institute of Fundamental Research, Colaba, Mumbai -5 (India)

    2007-06-28

    We have investigated the single and multiple ionizations of the C{sub 60} molecule in collisions with fast Si{sup q+} projectiles for various projectile charge states (q) between q = 6 and 14. The q-dependence of the ionization cross sections and their ratios is compared with the giant dipole plasmon resonance (GDPR) model. The excellent qualitative agreement with the model in case of single and double ionizations and also a reasonable agreement with the triple (and to some extent with quadruple) ionization (without evaporation) yields signify dominant contributions of the single-, double- and triple-plasmon excitations on the single- and multiple-ionization process.

  4. Electron impact ionization of B-like ion N2+. Resonance enhancement of the single-channel cross section

    International Nuclear Information System (INIS)

    Li Guohe; Qian Xingzhong; Pan Soufu

    1998-01-01

    The electron impact ionization cross sections of B-like ion N 2+ are calculated in the Coulomb-Born no exchange approximation by using R-matrix method, and the single differential cross section is given. The calculated results exhibit the Rydberg series of resonances. The resonance enhancement of the single-channel cross section is significantly greater than direct ionization cross section. It is agreement with that of Chidichimo

  5. Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    LaBel, Kenneth A.; OBryan, Martha V.; Chen, Dakai; Campola, Michael J.; Casey, Megan C.; Pellish, Jonathan A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Topper, Alyson D.; Ladbury, Raymond L.; hide

    2014-01-01

    We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

  6. Evaluation of a single-dose of intravenous magnesium sulphate for prevention of postoperative pain after inguinal surgery

    Directory of Open Access Journals (Sweden)

    Shashi Kiran

    2011-01-01

    Full Text Available This study was undertaken to study efficacy of single dose of intravenous magnesium sulphate to reduce post-operative pain in patients undergoing inguinal surgery. One hundred patients undergoing inguinal surgery were divided randomly in two groups of 50 each. The patients of magnesium sulphate group (Group-I received magnesium sulphate 50 mg/kg in 250 ml of isotonic sodium chloride solution IV whereas patients in control group (Group-II received same volume of isotonic sodium chloride over 30 minutes preoperatively. Anaesthesia was induced with propofol (2 mg/kg and pethidine (1 mg/kg. Atracurium besylate (0.5 mg/kg was given to facilitate insertion of LMA. Pain at emergence from anaesthesia and 2, 4, 6, 12 and 24 hours after surgery was evaluated. The timing and dosage of rescue analgesic during first 24 hrs after operation was noted. Pain in postop period was significantly lower in magnesium sulphate group in comparison to control group at emergence from anaesthesia and 2, 4, 6, 12 and 24 hrs postop [1.86 vs. 1.96 (P=0.138, 1.22 vs. 1.82 (P=0.001, 1.32 vs. 1.88 (P=0.000, 2.74 vs. 3.84 (P=0.000, 1.36 vs. 2.00 (P=0.000 and 0.78 vs 1.30 (P=0.000, respectively]. Patients in group-I were more sedated as compared to group-II [sedation score 1.86 vs. 1.40 (P=0.000]. Rescue analgesia requirement postoperatively in first 4, 8 and 16 hrs was significantly lower in patients of group-1 than in group- II [1.9 vs. 3.8 (P<0.05, 25.50 vs. 52.50 (P<0.05 and 0.000 vs. 7.5 (P<0.05]. Preoperative magnesium sulphate infusion decreases postop pain and requirement of rescue analgesia.

  7. Shearing single crystal magnesium in the close-packed basal plane at different temperatures

    Science.gov (United States)

    Han, Ming; Li, Lili; Zhao, Guangming

    2018-05-01

    Shear behaviors of single crystal magnesium (Mg) in close-packed (0001) basal plane along the [ 1 bar 2 1 bar 0 ], [ 1 2 bar 10 ], [ 10 1 bar 0 ] and [ 1 bar 010 ] directions were studied using molecular dynamics simulations via EAM potential. The results show that both shear stress-strain curves along the four directions and the motion path of free atoms during shearing behave periodic characteristics. It reveals that the periodic shear displacement is inherently related to the crystallographic orientation in single crystal Mg. Moreover, different temperatures in a range from 10 to 750 K were considered, demonstrating that shear modulus decreases with increasing temperatures. The results agree well with the MTS model. It is manifested that the modulus is independent with the shear direction and the size of the atomic model. This work also demonstrates that the classical description of shear modulus is still effective at the nanoscale.

  8. Single bolus dose of epidural magnesium prolongs the duration of analgesia in cardiac patients undergoing vascular surgeries

    Directory of Open Access Journals (Sweden)

    Amarja Sachin Nagre

    2017-01-01

    Full Text Available Background and Aims: Magnesium, a physiological antagonist of calcium and N-methyl-d-aspartate, has a role in the prevention of pain in patients undergoing surgery for peripheral vascular diseases with cardiac comorbidities such as ischaemic heart disease and coronary artery disease. The objective of our study was assessment of effects of epidural magnesium in cardiac patients undergoing vascular surgery. Methods: Sixty patients of either sex American Society of Anesthesiologists physical status III undergoing surgeries for peripheral vascular diseases were enrolled. The control group had 30 patients who received levobupivacaine 0.25% 10 ml with fentanyl 50 μg while 30 patients in study group received levobupivacaine 0.25% 10 ml with fentanyl 50 μg and magnesium 100 mg. The primary outcome was duration of analgesia. Sedation score, pain assessment using visual analogue scale (VAS, systolic blood pressure (SBP and diastolic blood pressure (DBP, heart rate (HR, respiratory rate (RR and fentanyl consumption were also recorded. Statistical analyses were performed using Minitab 15 statistical software. Results: Both groups were similar demographically and with respect to baseline HR, SBP, DBP and RR. In the study group, compared to the control group, duration of analgesia was 4.17 ± 1.07 h versus 1.55 ± 0.47 h (P < 0.01, sedation score were\\ better (P = 0.003 and the VAS scores was lower (P < 0.01. sConclusion: Epidural magnesium, added to levobupivacaine and fentanyl as a single bolus dose effectively prolongs the duration of analgesia in high-risk cardiac patients undergoing peripheral vascular surgery.

  9. Oxide films on magnesium and magnesium alloys

    International Nuclear Information System (INIS)

    Shih, T.-S.; Liu, J.-B.; Wei, P.-S.

    2007-01-01

    Magnesium alloys are very active and readily ignite during heating and melting. In this study, we discuss the combustion of magnesium and magnesium alloys and propose prospective anti-ignition mechanisms for magnesium alloys during the heating process. When magnesium and magnesium alloys were heated in air, the sample surfaces produced layers of thermally formed oxides. These thermally formed oxides played an important role in affecting the combustion of the magnesium and magnesium alloys. When magnesium was heated in air, brucite that formed in the early stage was then transformed into periclase by dehydroxylation. By extending the heating time, more periclase formed and increased in thickness which was associated with microcracks formation. When magnesium was heated in a protective atmosphere (SF 6 ), a film of MgF 2 formed at the interface between the oxide layer and the Mg substrate. This film generated an anti-ignition behavior which protected the substrate from oxidation. When solution-treated AZ80 alloy was heated, spinel developed at the interface between the thermally formed oxide layer and the Mg substrate, improving the anti-ignition properties of the substrate. In addition, we also explain the effects of beryllium in an AZB91 alloy on the ignition-proofing behavior

  10. Single-Photon Ionization Soft-X-Ray Laser Mass Spectrometry of Potential Hydrogen Storage Materials

    Science.gov (United States)

    Dong, F.; Bernstein, E. R.; Rocca, J. J.

    A desk-top size capillary discharge 46.9 nm lasear is applied in the gas phase study of nanoclusters. The high photon energy allows for single-photon ionization mass spectrometry with reduced cluster fragmentation. In the present studies, neutral Al m C n and Al m C n H x cluster are investigation for the first time. Single photon ionization through 46.9 nm, 118 nm, 193 nm lasers is used to detect neutral cluster distributions through time of flight mass spectrometry. Al m C n clusters are generated through laser ablation of a mixture of Al and C powders pressed into a disk. An oscillation of the vertical ionization energies (VIEs) of Al m C n clusters is observed in the experiments. The VIEs of Al m C n clusters changes as a function of the numbers of Al and C atoms in the clusters. Al m C n H x clusters are generated through an Al ablation plasma-hydrocarbon reaction, an Al-C ablation plasma reacting with H2 gas, or through cold Al m C n clusters reacting with H2 gas in a fast flow reactor. DFT and ab inito calculations are carried out to explore the structures, IEs, and electronic structures of Al m C n H x clusters. C=C bonds are favored for the lowest energy structures for Al m C n clusters. Be m C n H x are generated through a beryllium ablation plasma-hydrocarbon reaction and detected by single photon ionization of 193 nm laser. Both Al m C n H x and Be m C n H x are considered as potential hydrogen storage materials.

  11. Electron-ion correlation effects in ion-atom single ionization

    Energy Technology Data Exchange (ETDEWEB)

    Colavecchia, F.D.; Garibotti, C.R. [Centro Atomico Bariloche and Consejo Nacional de Investigaciones Cientificas y Tecnicas, 8400 San Carlos de Bariloche (Argentina); Gasaneo, G. [Departamento de Fisica, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahia Blanca (Argentina)

    2000-06-28

    We study the effect of electron-ion correlation in single ionization processes of atoms by ion impact. We present a distorted wave model where the final state is represented by a correlated function solution of a non-separable three-body continuum Hamiltonian, that includes electron-ion correlation as coupling terms of the wave equation. A comparison of the electronic differential cross sections computed with this model with other theories and experimental data reveals that the influence of the electron-ion correlation is more significant for low energy emitted electrons. (author). Letter-to-the-editor.

  12. Effect of bicarbonate on biodegradation behaviour of pure magnesium in a simulated body fluid

    International Nuclear Information System (INIS)

    Li, Zaichun; Song, Guang-Ling; Song, Shizhe

    2014-01-01

    The effect of bicarbonate on biodegradation of pure magnesium in a simulated body fluid is investigated by means of X-ray diffraction, X-ray photoelectron spectroscopy, polarization curve and electrochemical impedance spectroscopy. The results show that magnesium biodegrades rapidly and non-uniformly during 27 h of immersion in four simulated body fluid solutions containing different concentrations of bicarbonate. The biodegradation rate first decreases and then increases with time. A small amount of bicarbonate in simulated body fluid has an inhibition effect on the Mg dissolution, while an overdose of bicarbonate addition activates the magnesium surface in the simulated body fluid. The interesting phenomena can be interpreted by a surface film model involving precipitation of calcium carbonate and further ionization of bicarbonate in the simulated body fluids, incorporation of calcium, carbonate and phosphate compounds in the surface film, and development of chloride-induced pitting corrosion damage on the magnesium with time

  13. EXTENDED ANALYSIS OF THE SPECTRUM OF SINGLY IONIZED CHROMIUM (Cr II)

    Energy Technology Data Exchange (ETDEWEB)

    Sansonetti, Craig J.; Nave, Gillian [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2014-08-01

    We have made new observations of the spectrum of singly ionized chromium (Cr II) in the region 2850-37900 Å with the National Institute of Standards and Technology 2 m Fourier transform spectrometer. These data extend our previously reported observations in the near-ultra-violet region. We present a comprehensive list of more than 5300 Cr II lines classified as transitions among 456 even and 457 odd levels, 179 of which are newly located in this work. Using highly excited levels of the 3d {sup 4}({sup 5} D)5g, 3d {sup 4}({sup 5} D)6g, and 3d {sup 4}({sup 5}D)6h configurations, we derive an improved ionization energy of 132971.02 ± 0.12 cm{sup –1} (16.486305 ± 0.000015 eV)

  14. Magnesium Gluconate

    Science.gov (United States)

    Magnesium gluconate is used to treat low blood magnesium. Low blood magnesium is caused by gastrointestinal disorders, prolonged vomiting or ... disease, or certain other conditions. Certain drugs lower magnesium levels as well.This medication is sometimes prescribed ...

  15. Single ionization of Ne, Ar and Kr by proton impact: Single differential distributions in energy and angle

    Energy Technology Data Exchange (ETDEWEB)

    Otranto, S [CONICET and Dto. de Fisica, Universidad Nacional del Sur, 8000 BahIa Blanca (Argentina); Miraglia, J E [Instituto de AstronomIa y Fisica del Espacio, CONICET and Universidad de Buenos Aires C1428EGA (Argentina); Olson, R E, E-mail: sotranto@uns.edu.a [Physics Department, Missouri University of Science and Technology, Rolla MO 65409 (United States)

    2009-11-01

    In this work we present a theoretical study of singly differential cross sections in energy and angle for the single ionization of neon, argon and krypton by proton impact. Theoretical results obtained by means of the Continuum Distorted Wave-Eikonal initial state (CDW-EIS) model are compared to those provided by the First Born Approximation (FBA) and the classical trajectory Monte Carlo (CTMC) method as well as to experimental data from several laboratories. We note in particular for argon, that the CDW-EIS model does not reproduce the experimental data as accurately as expected, while the CTMC instead is in very good agreement.

  16. A practical theoretical formalism for atomic multielectron processes: direct multiple ionization by a single auger decay or by impact of a single electron or photon

    Science.gov (United States)

    Liu, Pengfei; Zeng, Jiaolong; Yuan, Jianmin

    2018-04-01

    Multiple electron processes occur widely in atoms, molecules, clusters, and condensed matters when they are interacting with energetic particles or intense laser fields. Direct multielectron processes (DMEP) are the most complicated among the general multiple electron processes and are the most difficult to describe theoretically. In this work, a unified and accurate theoretical formalism is proposed on the DMEP of atoms including the multiple auger decay and multiple ionization by an impact of a single electron or a single photon based on the atomic collision theory described by a correlated many-body Green's function. Such a practical treatment is made possible by taking consideration of the different coherence features of the atoms (matter waves) in the initial and final states. We first explain how the coherence characteristics of the ejected continuum electrons is largely destructed, by taking the electron impact direct double ionization process as an example. The direct double ionization process is completely different from the single ionization where the complete interference can be maintained. The detailed expressions are obtained for the energy correlations among the continuum electrons and energy resolved differential and integral cross sections according to the separation of knock-out (KO) and shake-off (SO) mechanisms for the electron impact direct double ionization, direct double and triple auger decay, and double and triple photoionization (TPI) processes. Extension to higher order DMEP than triple ionization is straight forward by adding contributions of the following KO and SO processes. The approach is applied to investigate the electron impact double ionization processes of C+, N+, and O+, the direct double and triple auger decay of the K-shell excited states of C+ 1s2{s}22{p}2{}2D and {}2P, and the double and TPI of lithium. Comparisons with the experimental and other theoretical investigations wherever available in the literature show that our

  17. Importance of polarization effects in electron impact single ionization of argon atom

    Energy Technology Data Exchange (ETDEWEB)

    Purohit, G., E-mail: g_vpurohit@yahoo.co [Department of Basic Sciences, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur 313 601 (India); Patidar, Vinod; Sud, K.K. [Department of Basic Sciences, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur 313 601 (India)

    2009-12-15

    We report the results of our calculations of triple differential cross section (TDCS) for electron impact single ionization (i.e. (e, 2e) processes) from the 3s shell of argon using a modified distorted wave Born approximation formalism by including correlation-polarization potential, which accounts for both correlation and polarization effects. We observe that DWBA formalism including polarization potential is able to reproduce most of the trends of experimental data and hence provide a future direction for further investigation of ionization process from the 3s shell of argon. We also compare our results with the available theoretical and experimental results. The present calculations significantly improve the agreement with the experimental results but still there are certain discrepancies, which is a matter of further investigation.

  18. Single Low-Dose Ionizing Radiation Induces Genotoxicity in Adult Zebrafish and its Non-Irradiated Progeny.

    Science.gov (United States)

    Lemos, J; Neuparth, T; Trigo, M; Costa, P; Vieira, D; Cunha, L; Ponte, F; Costa, P S; Metello, L F; Carvalho, A P

    2017-02-01

    This study investigated to what extent a single exposure to low doses of ionizing radiation can induce genotoxic damage in irradiated adult zebrafish (Danio rerio) and its non-irradiated F1 progeny. Four groups of adult zebrafish were irradiated with a single dose of X-rays at 0 (control), 100, 500 and 1000 mGy, respectively, and couples of each group were allowed to reproduce following irradiation. Blood of parental fish and whole-body offspring were analysed by the comet assay for detection of DNA damage. The level of DNA damage in irradiated parental fish increased in a radiation dose-dependent manner at day 1 post-irradiation, but returned to the control level thereafter. The level of DNA damage in the progeny was directly correlated with the parental irradiation dose. Results highlight the genotoxic risk of a single exposure to low-dose ionizing radiation in irradiated individuals and also in its non-irradiated progeny.

  19. Single ionization of helium by fast proton impact: Searching for projectile coherence

    International Nuclear Information System (INIS)

    Gassert, H; Waitz, M; Kim, H-K; Bauer, T; Laucke, A; Müller, Ch; Voigtsberger, J; Weller, M; Rist, J; Pahl, K; Honig, M; Pitzer, M; Zeller, S; Jahnke, T; Schmidt, L Ph H; Schmidt-Böcking, H; Chuluunbaatar, O; Bulychev, A A; Zaytsev, S A; Kouzakov, K A

    2015-01-01

    The fully differential cross section (FDCS) for single ionization p + He → p + e + He + at proton energy of 1 MeV is studied both experimentally and theoretically. The 3D angular electron distribution is presented. The role of electron-electron correlations both in a trial helium ground-state wave function and in the final helium state is inspected. (paper)

  20. Meas.of the Ratio Between Double and Single Ionization of Helium for Antiprotons

    CERN Multimedia

    2002-01-01

    The aim of this experiment is to measure the ratio between double and single ionization of helium by antiprotons in the energy range $>$~3~MeV. Comparison with already existing proton data will yield information on the mechanisms for double ionization, which could not be extracted from previous comparisons between ratios measured for equivelocity electrons and protons. The most basic information to be obtained from an antiproton experiment will be the amount of correlation existing between the two electrons in the ground-state helium atom.\\\\ \\\\ The equipment consists of a gas cell, which employs slow-ion collection via the so-called condenser-plate method for the absolute sum of partial-ionization cross sections and determination of the relative contribution of multiple charged ions by TOF. The gas cell has movable entrance and exit slits and a grid system to account for secondary emission from the collection of slow ions. Together with a field of 800~V/cm in the collision region, the potentials of the TOF sp...

  1. Production of magnesium metal

    Science.gov (United States)

    Blencoe, James G [Harriman, TN; Anovitz, Lawrence M [Knoxville, TN; Palmer, Donald A [Oliver Springs, TN; Beard, James S [Martinsville, VA

    2010-02-23

    A process of producing magnesium metal includes providing magnesium carbonate, and reacting the magnesium carbonate to produce a magnesium-containing compound and carbon dioxide. The magnesium-containing compound is reacted to produce magnesium metal. The carbon dioxide is used as a reactant in a second process. In another embodiment of the process, a magnesium silicate is reacted with a caustic material to produce magnesium hydroxide. The magnesium hydroxide is reacted with a source of carbon dioxide to produce magnesium carbonate. The magnesium carbonate is reacted to produce a magnesium-containing compound and carbon dioxide. The magnesium-containing compound is reacted to produce magnesium metal. The invention further relates to a process for production of magnesium metal or a magnesium compound where an external source of carbon dioxide is not used in any of the reactions of the process. The invention also relates to the magnesium metal produced by the processes described herein.

  2. Single and multiple ionization of noble gas atoms by H0 impact

    International Nuclear Information System (INIS)

    Sarkadi, L.; Gulyas, L.; Herczku, P.; Kovacs, S.T.S.; Koever, A.

    2012-01-01

    Complete text of publication follows. The understanding of the mechanisms of collisions between energetic charged particles and neutral atoms is of fundamental significance, and it has large importance in many research fields (plasma physics, astrophysics, materials science, etc.), as well as in number of practical applications. In the present work we measured total direct ionization and electron loss cross sections for the collisions of H 0 atoms with noble gas atoms (He, Ne, Ar, Kr) in the energy range 75-300 keV. The experiment was carried out at the 1.5 MV Van de Graaff accelerator of Atomki by coincident detection of the recoil target ions and the charge-state analyzed scattered projectiles. With this study we wished to obtain information about the role played by the electron of the H 0 projectile in the process of the single and multiple vacancy production induced by the collision. For this purpose we repeated the measurements also with proton projectile under the same experimental conditions. For calibration of the measuring system and normalization of our data we used the cross section values of Ref. [1]. The experimental results were analysed with using the classical trajectory Monte Carlo (CTMC) method. CTMC describes well the experimental data for both projectiles for the single vacancy creation, however we observed increasing deviation between the theory and experiment with increasing number of the created vacancies, as well as with decreasing atomic number of the target atoms. Fig. 1 shows our results obtained for the single, double and triple ionization (q = 1, 2, 3) of Kr at H 0 impact for the two cases when the outgoing projectile is H 0 (a) and H + (b), i.e., for pure ionization of the target, and ionization of the target with simultaneous electron loss of the projectile. The curves in the figure were obtained by two versions of the three-body CTMC theory: a conventional model (dashed curves); and a model taking partially account of the many

  3. Study on the non-target effect of ionizing radiation using single cell gel electrophoresis

    International Nuclear Information System (INIS)

    Wang Yan; Li Deguan; Liu Jianfeng; Chu Liping; Liu Qiang

    2008-01-01

    Objective: To assess the non-target effect of ionizing radiation by single cell gel electrophoresis (SCGE). Methods: Cross incubated the irradiated( 137 Cs; 2Gy) or non-irradiated lymphocytes of human peripheral blood in the irradiated or non-irradiated plasma respectively, then, assess the DNA damage of lymphocytes using SCGE analysis. Results: The lymphocytes incubated in the irradiated plasma presented more obvious DNA damage than the incubated in the non-irradiated plasma dose (P<0.05). Conclusion: The non-target effect of ionizing radiation can be assessed by SCGE, and the results confirm that cytokines may play a great role in it. (authors)

  4. Magnesium and Osteoporosis

    Directory of Open Access Journals (Sweden)

    Ferda Özdemir

    2004-03-01

    Full Text Available Osteoporosis (OP is a condition of bone fragility resulting from micro-architectural deterioration and decreased bone mass. OP depends on the interaction of genetic, hormonal, environmental and nutritional factors. Chronic low intakes of vitamin D and possibly magnesium, zinc, fluoride and vitamins K, B12, B6 and folic acid may predispose to osteoporosis. Magnesium is a mineral needed by every cell of your body. It helps maintain normal muscle and nerve function, keeps heart rhythm steady, and bones strong. Mg serves as co-factors for enzymes that help build bone matrix. Magnesium deficiency occurs due to excessive loss of magnesium in urine, gastrointestinal system disorders that cause a loss of magnesium or limit magnesium absorption, or a chronic low intake of magnesium. Signs of magnesium deficiency include confusion, disorientation, loss of appetite, depression, muscle contractions and cramps, tingling, numbness, abnormal heart rhythms, coronary spasm, and seizures. Magnesium deficiency alters calcium metabolism and the hormones that regulates calcium. Several studies have suggested that magnesium supplementation may improve bone mineral density and prevent fractures.

  5. Revised analysis of singly ionized xenon, Xe II

    International Nuclear Information System (INIS)

    Hansen, J.E.; Persson, W.

    1987-01-01

    We present a revised analysis of the spectrum of singly ionized xenon, Xe II. This spectrum has been reanalyzed on the basis of the wavelength material published by Drs J. C. Boyce and C. J. Humphreys. The latter has kindly placed the original wavelength list covering the wavelength range 10220-390 A at our disposal. We report 161 energy levels which have been identified on the basis of classifications of 950 lines. We report first f and g levels in Xe II. Also a number of g-factors have been determined for the first time and we give in total 75 g-factors. We have carried out least-squares fits to the even configurations and report the resulting parameter values and eigenvector compositions. A least-squares fit to the 5p 4 6p configuration is also reported. The levels have been named in jK and for many levels also in LS coupling. The former is the better coupling scheme for Xe II. We present an analysis of the 5s photoelectron satellite spectrum of Xe based on our calculated eigenvector compositions and calculations of transition probabilities for ground state transitions as well as lifetimes for the 6p levels. The latter are compared to recent experimental measurements. A list of wavelengths for observed laser transitions showing the present classifications and a discussion of the determination of the ionization potential of Xe II concludes the paper. (orig.)

  6. Coupled Cluster Studies of Ionization Potentials and Electron Affinities of Single-Walled Carbon Nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Bo; Govind, Niranjan; Apra, Edoardo; Klemm, Michael; Hammond, Jeff R.; Kowalski, Karol

    2017-02-03

    In this paper we apply equation-of-motion coupled cluster (EOMCC) methods in studies of vertical ionization potentials (IP) and electron affinities (EA) for sin- gled walled carbon nanotubes. EOMCC formulations for ionization potentials and electron affinities employing excitation manifolds spanned by single and double ex- citations (IP/EA-EOMCCSD) are used to study IPs and EAs of nanotubes as a function of nanotube length. Several armchair nanotubes corresponding to C20nH20 models with n = 2 - 6 have been used in benchmark calculations. In agreement with previous studies, we demonstrate that the electronegativity of C20nH20 systems remains, to a large extent, independent of nanotube length. We also compare IP/EA- EOMCCSD results with those obtained with the coupled cluster models with single and double excitations corrected by perturbative triples, CCSD(T), and density func- tional theory (DFT) using global and range-separated hybrid exchange-correlation functionals.

  7. Magnesium Borohydride: From Hydrogen Storage to Magnesium Battery**

    OpenAIRE

    Mohtadi, Rana; Matsui, Masaki; Arthur, Timothy S; Hwang, Son-Jong

    2012-01-01

    Beyond hydrogen storage: The first example of reversible magnesium deposition/stripping onto/from an inorganic salt was seen for a magnesium borohydride electrolyte. High coulombic efficiency of up to 94 % was achieved in dimethoxyethane solvent. This Mg(BH_4)_2 electrolyte was utilized in a rechargeable magnesium battery.

  8. Single and double ionization of helium by high-energy photon impact

    International Nuclear Information System (INIS)

    Andersson, L.R.; Burgdoerfer, J.

    1993-01-01

    Production of singly and doubly charged helium ions by impact of keV photons is studied. The ratio R ph = σ ph ++ /σ ph + for photoabsorption is calculated in the photon-energy range 2--18 keV using correlated initial- and final- state wave functions. Extrapolation towards symptotic photon energies yields R ph (ω → ∞) = 1.66% in agreement with previous predictions. Ionization due to Compton scattering, which becomes comparable to photoabsorption above ω ∼ 3 keV, is discussed

  9. Magnesium borohydride: from hydrogen storage to magnesium battery.

    Science.gov (United States)

    Mohtadi, Rana; Matsui, Masaki; Arthur, Timothy S; Hwang, Son-Jong

    2012-09-24

    Beyond hydrogen storage: The first example of reversible magnesium deposition/stripping onto/from an inorganic salt was seen for a magnesium borohydride electrolyte. High coulombic efficiency of up to 94 % was achieved in dimethoxyethane solvent. This Mg(BH(4))(2) electrolyte was utilized in a rechargeable magnesium battery. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Quasi free mechanism in single photon double ionization of helium

    Energy Technology Data Exchange (ETDEWEB)

    Schoeffler, Markus; Stuck, Christian [Frankfurt Univ., Frankfurt am Main (Germany). Inst. fuer Kernphysik; Lawrence Berkeley National Lab, Berkeley, CA (United States); Jahnke, Till; Waitz, Markus; Trinter, Florian; Lenz, Ute; Schmidt-Boecking, Horst; Doerner, Reinhard [Frankfurt Univ., Frankfurt am Main (Germany). Inst. fuer Kernphysik; Jones, Mathew; Landers, Allen [Auburn University, Auburn, AL (United States); Belkacem, Ali; Weber, Thorsten [Lawrence Berkeley National Lab, Berkeley, CA (United States); Cocke, Lew [Kansas State University, Manhattan, KS (United States)

    2012-07-01

    Double ionization of Helium by a single photon is widely believed to proceed through two mechanisms: knock-off (TS1) or shake-off, with the last one dominating at high photon energies. A new mechanism, termed ''Quasi Free Mechanism'' (QFM) was predicted 35 years ago by Amusia and coworkers, but escaped experimental observation till today. Here we provide the first proof of this mechanism using 800 eV photons from the Advanced Light Source. Fragments (electrons and ions) were measured in coincidence using momentum spectroscopy (COLTRIMS). He{sup (}2+) ions with zero momentum were found - the fingerprint for the QFM.

  11. Magnesium in pregnancy.

    Science.gov (United States)

    Dalton, Lynne M; Ní Fhloinn, Deirdre M; Gaydadzhieva, Gergana T; Mazurkiewicz, Ola M; Leeson, Heather; Wright, Ciara P

    2016-09-01

    Magnesium deficiency is prevalent in women of childbearing age in both developing and developed countries. The need for magnesium increases during pregnancy, and the majority of pregnant women likely do not meet this increased need. Magnesium deficiency or insufficiency during pregnancy may pose a health risk for both the mother and the newborn, with implications that may extend into adulthood of the offspring. The measurement of serum magnesium is the most widely used method for determining magnesium levels, but it has significant limitations that have both hindered the assessment of deficiency and affected the reliability of studies in pregnant women. Thus far, limited studies have suggested links between magnesium inadequacy and certain conditions in pregnancy associated with high mortality and morbidity, such as gestational diabetes, preterm labor, preeclampsia, and small for gestational age or intrauterine growth restriction. This review provides recommendations for further study and improved testing using measurement of red cell magnesium. Pregnant women should be counseled to increase their intake of magnesium-rich foods such as nuts, seeds, beans, and leafy greens and/or to supplement with magnesium at a safe level. © The Author(s) 2016. Published by Oxford University Press on behalf of the International Life Sciences Institute. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Imparting passivity to vapor deposited magnesium alloys

    Science.gov (United States)

    Wolfe, Ryan C.

    Magnesium has the lowest density of all structural metals. Utilization of low density materials is advantageous from a design standpoint, because lower weight translates into improved performance of engineered products (i.e., notebook computers are more portable, vehicles achieve better gas mileage, and aircraft can carry more payload). Despite their low density and high strength to weight ratio, however, the widespread implementation of magnesium alloys is currently hindered by their relatively poor corrosion resistance. The objective of this research dissertation is to develop a scientific basis for the creation of a corrosion resistant magnesium alloy. The corrosion resistance of magnesium alloys is affected by several interrelated factors. Among these are alloying, microstructure, impurities, galvanic corrosion effects, and service conditions, among others. Alloying and modification of the microstructure are primary approaches to controlling corrosion. Furthermore, nonequilibrium alloying of magnesium via physical vapor deposition allows for the formation of single-phase magnesium alloys with supersaturated concentrations of passivity-enhancing elements. The microstructure and surface morphology is also modifiable during physical vapor deposition through the variation of evaporation power, pressure, temperature, ion bombardment, and the source-to-substrate distance. Aluminum, titanium, yttrium, and zirconium were initially chosen as candidates likely to impart passivity on vapor deposited magnesium alloys. Prior to this research, alloys of this type have never before been produced, much less studied. All of these metals were observed to afford some degree of corrosion resistance to magnesium. Due to the especially promising results from nonequilibrium alloying of magnesium with yttrium and titanium, the ternary magnesium-yttrium-titanium system was investigated in depth. While all of the alloys are lustrous, surface morphology is observed under the scanning

  13. Magnesium stannide as a high-capacity anode for magnesium-ion batteries

    Science.gov (United States)

    Nguyen, Dan-Thien; Song, Seung-Wan

    2017-11-01

    Driven by the limited global resources of lithium, magnesium metal batteries are considered as potential energy storage systems. The battery chemistry of magnesium metal anode, however, limits the selection of electrolytes, cathode materials and working temperature, making the realization of magnesium metal batteries complicated. Herein, we report the development of a new magnesium-insertion anode, magnesium stannide (Mg2Sn), and demonstrate reversible electrochemical Mg2+-extraction and insertion of Mg2Sn anode at 0.2 V versus Mg, delivering discharge capacity of 270 mAhg-1 in a half-cell with the electrolyte of PhMgCl/THF and enabling of room temperature magnesium-ion batteries with Mg2Sn anode combined with Mg-free oxide cathode and conventional-type electrolyte of Mg(TFSI)2/diglyme. The combination of Mg2Sn anode with various cathodes and electrolytes holds great promise for enabling room temperature magnesium-ion batteries.

  14. Effect of magnesium deficiency on renal magnesium and calcium transport in the rat.

    OpenAIRE

    Carney, S L; Wong, N L; Quamme, G A; Dirks, J H

    1980-01-01

    Recollection of micropuncture experiments were performed on acutely thyroparathyroidectomized rats rendered magnesium deficient by dietary deprivation. Urinary magnesium excretion fell from a control of 15 to 3% of the filtered load after magnesium restriction. The loop of Henle, presumably the thick ascending limb, was the major modulator for renal magnesium homeostasis. The transport capacity for magnesium, however, was less in deficient rats than control animals. Absolute magnesium reabsor...

  15. Comprehensive Wavelengths, Energy Levels, and Hyperfine Structure Parameters of Singly-Ionized Iron-Group Elements

    Science.gov (United States)

    Nave, Gillian

    We propose to measure wavelengths, energy levels, and hyperfine structure parameters of Ni II, Mn II, Sc II and other singly-ionized iron-group elements, covering the wavelength range 80 nm to 5500 nm. We shall use archival data from spectrometers at NIST and Kitt Peak National Observatory for spectra above 140 nm. Additional experimental observations will be taken if needed using Fourier transform spectrometers at NIST. Spectra will be taken using our normal incidence grating spectrograph to provide better sensitivity than the FT spectra and to extend the wavelength range down to 80 nm. We aim to produce a comprehensive description of the spectra of all singly-ionized iron- group elements. The wavelength uncertainty of the strong lines will be better than 1 part in 10^7. For most singly-ionized iron-group elements available laboratory data have uncertainties an order of magnitude larger than astronomical observations over wide spectra ranges. Some of these laboratory measurements date back to the 1960's. Since then, Fourier transform spectroscopy has made significant progress in improving the accuracy and quantity of data in the UV-vis-IR region, but high quality Fourier transform spectra are still needed for Mn II, Ni II and Sc II. Fourier transform spectroscopy has low sensitivity in the VUV region and is limited to wavelengths above 140 nm. Spectra measured with high-resolution grating spectrographs are needed in this region in order to obtain laboratory data of comparable quality to the STIS and COS spectrographs on the Hubble Space Telescope. Currently, such data exist only for Fe II and Cr II. Lines of Sc II, V II, and Mn II show hyperfine structure, but hyperfine structure parameters have been measured for relatively few lines of these elements. Significant errors can occur if hyperfine structure is neglected when abundances are determined from stellar spectra. Measurements of hyperfine structure parameters will be made using Fourier transform spectroscopy

  16. Double and single ionization of helium by 58-keV X-rays

    International Nuclear Information System (INIS)

    Spielberger, L.; Buslaps, T.; Braeuning, H.; Gemmell, D.S.; Schmidt-Boecking, H.

    1996-03-01

    We have measured the ratio of cross sections for double to single ionization of helium by Compton scattering, R c =σ c ++ /σ c + at a photon energy of 58 keV using Cold Target Recoil Ion Momentum Spectroscopy. We find a value R c =(0.84 -11 +08 )% that is in agreement with the asymptotic limits predicted by Andersson and Burgdoerfer (Phys. Rev. A 50, R2810 (1994)) and Suric et al. (Phys. Rev. Lett. 73, 790 (1994)). (orig.)

  17. Magnesium, magnesium alloys, and magnesium composites

    National Research Council Canada - National Science Library

    Gupta, M; Sharon, Nai Mui Ling

    2011-01-01

    .... With the popularity of magnesium-based materials in the automotive, aerospace, electronics, and sports equipment industries, and its unique role as a lightweight, energy-saving and high-performance...

  18. Myth or Reality-Transdermal Magnesium?

    Science.gov (United States)

    Gröber, Uwe; Werner, Tanja; Vormann, Jürgen; Kisters, Klaus

    2017-07-28

    In the following review, we evaluated the current literature and evidence-based data on transdermal magnesium application and show that the propagation of transdermal magnesium is scientifically unsupported. The importance of magnesium and the positive effects of magnesium supplementation are extensively documented in magnesium deficiency, e.g., cardiovascular disease and diabetes mellitus. The effectiveness of oral magnesium supplementation for the treatment of magnesium deficiency has been studied in detail. However, the proven and well-documented oral magnesium supplementation has become questioned in the recent years through intensive marketing for its transdermal application (e.g., magnesium-containing sprays, magnesium flakes, and magnesium salt baths). In both, specialist and lay press as well as on the internet, there are increasing numbers of articles claiming the effectiveness and superiority of transdermal magnesium over an oral application. It is claimed that the transdermal absorption of magnesium in comparison to oral application is more effective due to better absorption and fewer side effects as it bypasses the gastrointestinal tract.

  19. Cathodoluminescence study of vickers indentations in magnesium ...

    African Journals Online (AJOL)

    Vickers diamond pyramid indentations made in single crystal of magnesium oxide (MgO) were examined in an environmental scanning electron microscope interfaced with an AVS-2000 spectrophotometer for luminescence. Three distinct zones around the indentations were identified to exhibit cathodoluminescence, which ...

  20. Concurrent irradiation effects with ionization and displacement on the formation of defect clusters in magnesium aluminate spinel

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Kazuhiro; Morisaki, Rieko; Kinoshita, Chiken [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Abe, Hiroaki; Naramoto, Hiroshi

    1997-03-01

    Single crystals of MgAl{sub 2}O{sub 4} were irradiated concurrently with a homogeneous ion beam and a focused electron beam in TEM-accelerator facilities to get insight into the concurrent irradiation effects with ionization and displacements. Various kinds of 30 or 300 keV ions (He{sup +}, O{sup +}, Mg{sup +}, Ar{sup +} and Xe{sup +}) and 200 keV or 1 MeV electrons were used to provide a wide range of nuclear (S{sub n}) and ionizing (S{sub e}) stopping powers. Dislocation loops were formed both inside and outside the electron beam at 870 K under concurrent irradiation with 30 keV ions (He{sup +}, Ar{sup +} and Xe{sup +}) and 1 MeV electrons. In the case of irradiation with 300 keV ions and 200 keV electrons, on the other hand, a preferential formation of voids or bubbles and a suppressive formation of dislocation loops were observed inside the electron beam. On the basis of these results, we pointed out the importance of the nuclear stopping power which causes the diffusion of cations toward the outside of the focused electron beam. (author)

  1. Magnesium stearine production via direct reaction of palm stearine and magnesium hydroxide

    Science.gov (United States)

    Pratiwi, M.; Ylitervo, P.; Pettersson, A.; Prakoso, T.; Soerawidjaja, T. H.

    2017-06-01

    The fossil oil production could not compensate with the increase of its consumption, because of this reason the renewable alternative energy source is needed to meet this requirement of this fuel. One of the methods to produce hydrocarbon is by decarboxylation of fatty acids. Vegetable oil and fats are the greatest source of fatty acids, so these can be used as raw material for biohydrocarbon production. From other researchers on their past researchs, by heating base soap from divalent metal, those metal salts will decarboxylate and produce hydrocarbon. This study investigate the process and characterization of magnesium soaps from palm stearine by Blachford method. The metal soaps are synthesized by direct reaction of palm stearine and magnesium hydroxide to produce magnesium stearine and magnesium stearine base soaps at 140-180°C and 6-10 bar for 3-6 hours. The operation process which succeed to gain metal soaps is 180°C, 10 bar, for 3-6 hours. These metal soaps are then compared with commercial magnesium stearate. Based on Thermogravimetry Analysis (TGA) results, the decomposition temperature of all the metal soaps were 250°C. Scanning Electron Microscope with Energy Dispersive X-ray (SEM-EDX) analysis have shown the traces of sodium sulphate for magnesium stearate commercial and magnesium hydroxide for both type of magnesium stearine soaps. The analysis results from Microwave Plasma-Atomic Emission Spectrometry (MP-AES) have shown that the magnesium content of magnesium stearine approximate with magnesium stearate commercial and lower compare with magnesium stearine base soaps. These experiments suggest that the presented saponification process method could produced metal soaps comparable with the commercial metal soaps.

  2. Low magnesium level

    Science.gov (United States)

    Low magnesium level is a condition in which the amount of magnesium in the blood is lower than normal. The medical ... that convert or use energy ( metabolism ). When the level of magnesium in the body drops below normal, ...

  3. System and process for production of magnesium metal and magnesium hydride from magnesium-containing salts and brines

    Science.gov (United States)

    McGrail, Peter B.; Nune, Satish K.; Motkuri, Radha K.; Glezakou, Vassiliki-Alexandra; Koech, Phillip K.; Adint, Tyler T.; Fifield, Leonard S.; Fernandez, Carlos A.; Liu, Jian

    2016-11-22

    A system and process are disclosed for production of consolidated magnesium metal products and alloys with selected densities from magnesium-containing salts and feedstocks. The system and process employ a dialkyl magnesium compound that decomposes to produce the Mg metal product. Energy requirements and production costs are lower than for conventional processing.

  4. Anticorrosive magnesium hydroxide coating on AZ31 magnesium alloy by hydrothermal method

    International Nuclear Information System (INIS)

    Zhu Yanying; Wu Guangming; Xing Guangjian; Li Donglin; Zhao Qing; Zhang Yunhong

    2009-01-01

    Magnesium alloys are potential biodegradable biomaterials in orthopedic surgery. However, the rapid degradation rate has limited their application in biomedical field. A great deal of studies have been done to improve the resistance of magnesium alloys. In this article, An anticorrosive magnesium hydroxide coating with a thickness of approximately 100μm was formed on an AZ31 magnesium alloy by hydrothermal method. The morphology of the coatings were observed by an optical microscope and SEM. And the samples were soaked in hank's solution (37 deg. C) to investigate the corrosion resistance. Magnesium alloy AZ31 with magnesium hydroxide coatings present superior corrosion resistance than untreated samples.

  5. Magnesium and Space Flight

    Science.gov (United States)

    Smith, Scott M.; Zwart, Sara R.

    2015-01-01

    Magnesium is an essential nutrient for muscle, cardiovascular, and bone health on Earth, and during space flight. We sought to evaluate magnesium status in 43 astronauts (34 male, 9 female; 47 ± 5 years old, mean ± SD) before, during, and after 4–6-month space missions. We also studied individuals participating in a ground analog of space flight (head-down-tilt bed rest; n = 27 (17 male, 10 female), 35 ± 7 years old). We evaluated serum concentration and 24-h urinary excretion of magnesium, along with estimates of tissue magnesium status from sublingual cells. Serum magnesium increased late in flight, while urinary magnesium excretion was higher over the course of 180-day space missions. Urinary magnesium increased during flight but decreased significantly at landing. Neither serum nor urinary magnesium changed during bed rest. For flight and bed rest, significant correlations existed between the area under the curve of serum and urinary magnesium and the change in total body bone mineral content. Tissue magnesium concentration was unchanged after flight and bed rest. Increased excretion of magnesium is likely partially from bone and partially from diet, but importantly, it does not come at the expense of muscle tissue stores. While further study is needed to better understand the implications of these findings for longer space exploration missions, magnesium homeostasis and tissue status seem well maintained during 4–6-month space missions. PMID:26670248

  6. Magnesium and Space Flight

    Directory of Open Access Journals (Sweden)

    Scott M. Smith

    2015-12-01

    Full Text Available Magnesium is an essential nutrient for muscle, cardiovascular, and bone health on Earth, and during space flight. We sought to evaluate magnesium status in 43 astronauts (34 male, 9 female; 47 ± 5 years old, mean ± SD before, during, and after 4–6-month space missions. We also studied individuals participating in a ground analog of space flight (head-down-tilt bed rest; n = 27 (17 male, 10 female, 35 ± 7 years old. We evaluated serum concentration and 24-h urinary excretion of magnesium, along with estimates of tissue magnesium status from sublingual cells. Serum magnesium increased late in flight, while urinary magnesium excretion was higher over the course of 180-day space missions. Urinary magnesium increased during flight but decreased significantly at landing. Neither serum nor urinary magnesium changed during bed rest. For flight and bed rest, significant correlations existed between the area under the curve of serum and urinary magnesium and the change in total body bone mineral content. Tissue magnesium concentration was unchanged after flight and bed rest. Increased excretion of magnesium is likely partially from bone and partially from diet, but importantly, it does not come at the expense of muscle tissue stores. While further study is needed to better understand the implications of these findings for longer space exploration missions, magnesium homeostasis and tissue status seem well maintained during 4–6-month space missions.

  7. In vitro studies on magnesium uptake by rumen epithelium using magnesium-28

    International Nuclear Information System (INIS)

    Martens, H.; Harmeyer, J.; Breves, G.

    1976-01-01

    Magnesium-28 transfer across the rumen epithelium has been studied using surviving epithelia in an in vitro system. Net absorption of magnesium in the direction from lumen to blood could be observed as the result of two opposite unidirectional fluxes of different magnitude. Net uptake of magnesium occurred against an electrical potential difference, and was associated with the presence of an unaltered transmural potential difference in the mucosal tissue. Both the net transfer of magnesium and the transmural potential difference decreased during two hours of incubation. Unidirectional fluxes of magnesium and net efflux from the lumen were markedly reduced although not completely inhibited by the addition of ouabain (10 -4 mol/l). The findings suggest that the mechanism of magnesium absorption by the rumen epithelium can be considered as an active transport process, and that the rumen is the main area of magnesium absorption in the living animal. (author)

  8. Magnesium, magnesium alloys, and magnesium composites

    National Research Council Canada - National Science Library

    Gupta, M; Sharon, Nai Mui Ling

    2011-01-01

    ... of science, characteristics, and applications. It emphasizes the properties of magnesium-based composites and the effects of different types of reinforcements, from micron length to nanometer scale, on the properties of the resulting composites...

  9. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  10. Reduced Mortality in Maintenance Haemodialysis Patients on High versus Low Dialysate Magnesium: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Christoph Schmaderer

    2017-08-01

    Full Text Available Background: Although low magnesium levels have been associated with an increased mortality in dialysis patients, they are kept low by routinely-used dialysates containing 0.50 mmol/L magnesium. Thus, we investigated the impact of a higher dialysate magnesium concentration on mortality. Methods: 25 patients on high dialysate magnesium (HDM of 0.75 mmol/L were 1:2 matched to 50 patients on low dialysate magnesium (LDM of 0.50 mmol/L and followed up for 3 years with regards to all-cause and cardiovascular mortality. Patients were matched according to age, gender, a modified version of the Charlson Comorbidity Index (CCI, and smoking status. Results: During the follow-up period, five patients died in the HDM and 18 patients in the LDM group. Patients in the HDM group had significantly higher ionized serum magnesium levels than matched controls (0.64 ± 0.12 mmol/L vs. 0.57 ± 0.10 mmol/L, p = 0.034. Log rank test showed no difference between treatment groups for all-cause mortality. After adjustment for age and CCI, Cox proportional hazards regression showed that HDM independently predicted a 65% risk reduction for all-cause mortality (hazard ratio 0.35, 95% confidence interval [CI]: 0.13, 0.97. Estimated 3-year probability of death from a cardiovascular event was 14.5% (95% CI: 7.9, 25.8 in the LDM group vs. 0% in the HDM group. Log rank test found a significant group difference for cardiovascular mortality (χ2 = 4.15, p = 0.042. Conclusions: Our data suggests that there might be a beneficial effect of an increased dialysate magnesium on cardiovascular mortality in chronic dialysis patients.

  11. Magnesium Hydroxide

    Science.gov (United States)

    Magnesium hydroxide is used on a short-term basis to treat constipation.This medication is sometimes prescribed ... Magnesium hydroxide come as a tablet and liquid to take by mouth. It usually is taken as ...

  12. Research Progress in Plasma arc welding of Magnesium Alloys and Magnesium Matrix Composites

    Science.gov (United States)

    Hui, Li; Yang, Zou; Yongbo, Li; Lei, Jiao; Ruijun, Hou

    2017-11-01

    Magnesium alloys and magnesium matrix composites by means of its excellent performance have wide application prospect in electronics, automotive, biotechnology, aerospace field, and welding technology has become a key of restricting its application. This paper describes the welding characteristics of magnesium, the obvious advantages in the application and the domestic and foreign research advance technology of plasma arc welding of magnesium, and summarizes the existing problems and development trends of plasma arc welding technology of magnesium.

  13. FOCUS ON MAGNESIUM BASED DRUGS

    Directory of Open Access Journals (Sweden)

    I. I. Esenova

    2011-01-01

    Full Text Available Magnesium deficiency in the organism is one of the most common human deficiency states. The prevalence of magnesium deficiency is about 15%, and suboptimal magnesium level is observed more than in 30% of people in the general population. Clinical signs of hypomagnesaemia are observed in 40% of patients in general care hospitals, in 70% of patients - in intensive care units, and magnesium deficiency occurs in 90% of patients with acute coronary syndrome. Magnesium metabolic disorders in the organism accelerate significantly development of complications of coronary heart disease, hypertension, type 2 diabetes, asthma and a number of neurological and psychiatric diseases. The value of this macro in the body is well studied, and its daily need is identified depending on age and sex. It is known that magnesium intake with the food does not cover an organism need. It is a rationale for preventive and therapeutic use of magnesium based drugs in various diseases. Organic salts of magnesium are recommended for these purposes. Magnesium metabolic disorders, approaches to pharmacotherapeutic correction of magnesium deficiency, advantages of magnesium salts of orotic acid are reviewed.

  14. Magnesium Oxide

    Science.gov (United States)

    Magnesium is an element your body needs to function normally. Magnesium oxide may be used for different reasons. Some people use it as ... one to four times daily depending on which brand is used and what condition you have. Follow ...

  15. Total and single differential cross sections for the electron impact ionization of the ground state of helium

    International Nuclear Information System (INIS)

    Singh, T.S.C.; Choudhury, K.B.; Singh, M.B.; Deb, N.C.; Mukherjee, S.C.; Mazumdar, P.S.

    1997-01-01

    Total cross sections (TCS) and single differential cross sections (SDCS) have been computed for the single ionization of the ground state of helium by electron impact in a distorted wave formalism which takes into account the effects of the initial and final channel distortions. The present TCS and SDCS results are in fair agreement with the measured values and other theoretical predictions for the incident electron energy E i > 150 eV. (orig.)

  16. Revised energy levels of singly ionized lanthanum

    Science.gov (United States)

    Güzelçimen, Feyza; Tonka, Mehdi; Uddin, Zaheer; Bhatti, Naveed Anjum; Windholz, Laurentius; Kröger, Sophie; Başar, Gönül

    2018-05-01

    Based on the experimental wavenumbers of 344 spectral lines from calibrated Fourier transform (FT) spectra as well as wavenumbers of 81 lines from the wavelength tables from literature, the energy of 115 fine structure levels of singly ionized lanthanum has been revised by weighted global fits. The classifications of the lines are provided by numerous previous investigations of lanthanum by different spectroscopic methods and authors. For the high accurate determination of the center of gravity wavenumbers from the experimental spectrum, the hyperfine constants of the involved levels have been taken into account, if possible. For the 94 levels with known hyperfine constants the accuracy of energy values is better than 0.01 cm-1. For 34 levels the magnetic dipole hyperfine constants A have been determined from FT spectra as part of this work. For four of these 34 levels even electric quadrupole hyperfine constants B could be estimated. For levels, which have experimentally unknown hyperfine constants and which are connected only by lines not found in the FT spectra but taken from literature, the uncertainties of energy values are about a factor of 10 higher. A list of all revised level energies together with a compilation of hyperfine structure data is given as well as a list of all lines used.

  17. Increases in Intravenous Magnesium Use among Hospitalized Patients: An Institution Cross-Sectional Experience

    Directory of Open Access Journals (Sweden)

    Bryce A. Kiberd

    2015-06-01

    Full Text Available Background: Among hospitalized patients, indications for the measurement of magnesium levels and treatment of hypomagnesemia with intravenous magnesium are not well defined. Recently, there have been reports of worldwide shortages of intravenous magnesium sulphate. Objective: To examine secular trends in the administration of intravenous magnesium on hospital wards at a tertiary care institution. The secondary objective is to identify factors associated with magnesium use among admitted patients. Methods: Retrospective cross-section review of hospitalized patients at a single Canadian tertiary care center. Utilization of non-parental nutrition intravenous magnesium from 2003 to 2013 stratified by hospital ward was examined. In addition, patient level data from select wards (including medical and surgical services was examined at early and more recent time period (4/2006 versus 4/2013. Results: Among the 248,329 hospitalized patients, intravenous magnesium use increased by 2.86 fold from 2003 to 2013. Not all wards had an increase whereas some had nearly a 10 fold increase in use. In the sample ( n = 769, (adjusting for admission magnesium level, presence of an indication for intravenous magnesium, ward location, comorbidity and demographics intravenous magnesium administration was higher (25.8 % versus 5.5 % in 2013 versus 2006 (OR 13.91 (95 % CI, 6.21–31.17, p < 0.001. Despite this increase in intravenous magnesium administration, <3 % of patients were admitted on oral magnesium in 2006 and 2013. For patients receiving intravenous magnesium only a minority were discharged on oral therapy despite low levels. Conclusions: This center has witnessed a considerable increase in the use of in-hospital intravenous magnesium over the last 6 years that cannot be explained for by medical indications. The risks and benefits of this therapy deserve further study. If this change in practice is representative of other North American hospitals, it may be

  18. Calcium and magnesium silicate hydrates

    International Nuclear Information System (INIS)

    Lothenbach, B.; L'Hopital, E.; Nied, D.; Achiedo, G.; Dauzeres, A.

    2015-01-01

    Deep geological disposals are planed to discard long-lived intermediate-level and high-level radioactive wastes. Clay-based geological barriers are expected to limit the ingress of groundwater and to reduce the mobility of radioelements. In the interaction zone between the cement and the clay based material alteration can occur. Magnesium silicate hydrates (M-S-H) have been observed due to the reaction of magnesium sulfate containing groundwater with cements or in the interaction zone between low-pH type cement and clays. M-S-H samples synthesized in the laboratory showed that M-S-H has a variable composition within 0.7 ≤ Mg/Si ≤ 1.5. TEM/EDS analyses show an homogeneous gel with no defined structure. IR and 29 Si NMR data reveal a higher polymerization degree of the silica network in M-S-H compared to calcium silicate hydrates (C-S-H). The presence of mainly Q 3 silicate tetrahedrons in M-S-H indicates a sheet like or a triple-chain silica structure while C-S-H is characterised by single chain-structure. The clear difference in the silica structure and the larger ionic radius of Ca 2+ (1.1 Angstrom) compared to Mg 2+ (0.8 Angstrom) make the formation of an extended solid solution between M-S-H and C-S-H gel improbable. In fact, the analyses of synthetic samples containing both magnesium and calcium in various ratios indicate the formation of separate M-S-H and C-S-H gels with no or very little uptake of magnesium in CS-H or calcium in M-S-H

  19. Magnesium motorcycle applications

    International Nuclear Information System (INIS)

    Jianyong Cao; Zonghe Zhang; Dongxia Xiang; Jun Wang

    2005-01-01

    Magnesium, the lightest engineering structural metal, has been comprehensively used in castings of aviation and aerospace, communication and transportation, and IT components. This paper introduced the history, advantages and difficulties of magnesium castings for motorcycle application as well as its application state in China. It also indicated the production situation of magnesium motorcycle components in CQMST and difficulties need to overcome for further development. (orig.)

  20. Design of the Intravenous Magnesium Efficacy in Acute Stroke (IMAGES) trial

    OpenAIRE

    Bradford, A.; Lees, K.

    2000-01-01

    The Intravenous Magnesium Efficacy in Acute Stroke (IMAGES) trial is a multicentre,randomised, placebo-controlled trial of magnesium sulphate (MgSO4) funded by the UK Medical Research Council. When complete, it will be the largest single neuroprotective study undertaken to date. Conscious patients presenting within 12 h of acute stroke with limb weakness are eligible. The primary outcome measure is combined death and disability as measured using the Barthel Index at 90-day follow up. By rando...

  1. Magnesium sulfate reduces formalin-induced orofacial pain in rats with normal magnesium serum levels.

    Science.gov (United States)

    Srebro, Dragana P; Vučković, Sonja M; Dožić, Ivan S; Dožić, Branko S; Savić Vujović, Katarina R; Milovanović, Aleksandar P; Karadžić, Branislav V; Prostran, Milica Š

    2018-02-01

    In humans, orofacial pain has a high prevalence and is often difficult to treat. Magnesium is an essential element in biological a system which controls the activity of many ion channels, neurotransmitters and enzymes. Magnesium produces an antinociceptive effect in neuropathic pain, while in inflammatory pain results are not consistent. We examined the effects of magnesium sulfate using the rat orofacial formalin test, a model of trigeminal pain. Male Wistar rats were injected with 1.5% formalin into the perinasal area, and the total time spent in pain-related behavior (face rubbing) was quantified. We also spectrophotometrically determined the concentration of magnesium and creatine kinase activity in blood serum. Magnesium sulfate administered subcutaneously (0.005-45mg/kg) produced significant antinociception in the second phase of the orofacial formalin test in rats at physiological serum concentration of magnesium. The effect was not dose-dependent. The maximum antinociceptive effect of magnesium sulfate was about 50% and was achieved at doses of 15 and 45mg/kg. Magnesium did not affect increase the levels of serum creatine kinase activity. Preemptive systemic administration of magnesium sulfate as the only drug can be used to prevent inflammatory pain in the orofacial region. Its analgesic effect is not associated with magnesium deficiency. Copyright © 2017 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  2. Function of magnesium aluminate hydrate and magnesium nitrate ...

    Indian Academy of Sciences (India)

    MgO was added both as spinel (MgAl2O4) forming precursor i.e. magnesium aluminate hydrate, and magnesium nitrate. Sintering investigations were conducted in the temperature range 1500–1600°C with 2 h soaking. Structural study of sintered pellets was carried out by extensive XRD analysis. Scanning electron mode ...

  3. Magnesium compounds

    Science.gov (United States)

    Kramer, D.A.

    2007-01-01

    Seawater and natural brines accounted for about 52 percent of U.S. magnesium compounds production in 2006. Dead-burned magnesia was produced by Martin Marietta Magnesia Specialties from well brines in Michigan. Caustic-calcined magnesia was recovered from sea-water by Premier Chemicals in Florida; from well brines in Michigan by Martin Marietta and Rohm and Haas; and from magnesite in Nevada by Premier Chemicals. Intrepid Potash-Wendover and Great Salt Lake Minerals recovered magnesium chloride brines from the Great Salt Lake in Utah. Magnesium hydroxide was produced from brucite by Applied Chemical Magnesias in Texas, from seawater by SPI Pharma in Delaware and Premier Chemicals in Florida, and by Martin Marietta and Rohm and Haas from their operations mentioned above. About 59 percent of the magnesium compounds consumed in the United States was used for refractories that are used mainly to line steelmaking furnaces. The remaining 41 percent was consumed in agricultural, chemical, construction, environmental and industrial applications.

  4. Elastic scattering of electrons from singly ionized argon

    International Nuclear Information System (INIS)

    Griffin, D.C.; Pindzola, M.S.

    1996-01-01

    Recently, Greenwood et al. [Phys. Rev. Lett. 75, 1062 (1995)] reported measurements of large-angle elastic scattering of electrons from singly ionized argon at an energy of 3.3 eV. They compared their results for the differential cross section with cross sections determined using phase shifts obtained from two different scattering potentials and found large discrepancies between theory and experiment at large angles. They state that these differences may be due to the effects of polarization of the target, which are not included in their calculations, as well as inaccurate representations of electron exchange in the local scattering potentials that are employed to determine the phase shifts. In order to test these proposed explanations of the discrepancies, we have carried out calculations of elastic scattering from Ar + using the R-matrix method. We compare both a single-state calculation, which does not include polarization, and a 17-state calculation, in which the effects of dipole polarizability are included through the use of polarization pseudostates within the close-coupling expansion, to each other and with the measurements. We find some differences between the two calculations at intermediate scattering angles, but very close agreement at angles above 100 degree. Although the calculated cross sections agree with experiment between 120 degree and 135 degree, large discrepancies persist at angles above 135 degree. We conclude that the differences between the measurements and theory cannot be explained on the basis of an inaccurate representation of electron exchange or polarization of the target. copyright 1996 The American Physical Society

  5. Innovative Vacuum Distillation for Magnesium Recycling

    Science.gov (United States)

    Zhu, Tianbai; Li, Naiyi; Mei, Xiaoming; Yu, Alfred; Shang, Shixiang

    Magnesium recycling now becomes a very important subject as magnesium consumption increases fast around the world. All commonly used magnesium die-casting alloys can be recycled and recovered to the primary metal quality. The recycled materials may be comprised of biscuits, sprues, runners, flash, overflows, dross, sludge, scrap parts, and old parts that are returned from service, An innovative magnesium recycle method, vacuum distillation, is developed and proved out to be able to recycle magnesium scraps, especially machining chips, oily magnesium, smelting sludge, dross or the mixture. With this process at a specific temperature and environment condition, magnesium in scraps can be gasified and then solidified to become crystal magnesium crown. This `recycled' magnesium crown is collected and used as the raw material of magnesium alloys. The experimental results show the vacuum distillation is a feasible and plausible method to recycle magnesium. Further, the cost analysis will be addressed in this paper.

  6. Study in the plasma with non-equilibrium ionization state by relative intensities in K-spectra of multicharged ions

    International Nuclear Information System (INIS)

    Bojko, V.A.; Skobelev, I.Yu.; Faenov, A.Ya.

    1984-01-01

    The pressure of the K-spectra formation of multicharge h-, He-, Li-like ions in a plasma with an arbitrary ionization state are considered. It is shown that comparison of experimental and theoretical data on the intensities of f a number of spectral lines belonging to such ions allows one to determine both the plasma electron temperature and ion distribution versus the ionization degre ees. The proposed method of plasma diagnostics is used for measuring parameters of the expanding laser-produced magnesium plasme

  7. INVESTIGATION OF MAGNESIUM ALLOYS MACHINABILITY

    Directory of Open Access Journals (Sweden)

    Berat Barıs BULDUM

    2013-01-01

    Full Text Available Magnesium is the lightest structural metal. Magnesium alloys have a hexagonal lattice structure, which affects the fundamental properties of these alloys. Plastic deformation of the hexagonal lattice is more complicated than in cubic latticed metals like aluminum, copper and steel. Magnesium alloy developments have traditionally been driven by industry requirements for lightweight materials to operate under increasingly demanding conditions. Magnesium alloys have always been attractive to designers due to their low density, only two thirds that of aluminium and its alloys [1]. The element and its alloys take a big part of modern industry needs. Especially nowadays magnesium alloys are used in automotive and mechanical (trains and wagons manufacture, because of its lightness and other features. Magnesium and magnesium alloys are the easiest of all metals to machine, allowing machining operations at extremely high speed. All standard machining operations such as turning, drilling, milling, are commonly performed on magnesium parts.

  8. Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Adams, C.; et al.

    2018-04-07

    The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.

  9. Local clouds ionization, temperatures, electron densities and interfaces, from GHRS and IMAPS spectra of epsilon Canis Majoris

    CERN Document Server

    Gry, C; Gry, Cecile; Jenkins, Edward B.

    2001-01-01

    The composition and physical properties of several local clouds, including the Local Interstellar Cloud (LIC) in which the Sun is embedded, are derived from absorption features in the UV spectrum of the star epsilon CMa. We derive temperatures and densities for three components by combining our interpretations of the ionization balance of magnesium and the relative population of C II in an excited fine-structure level. We find that for the LIC n(e) = 0.12 +/-0.05 cm-3 and T = 7000 +/-1200 K. We derive the ionization fractions of hydrogen and discuss the ionizing processes. In particular the hydrogen and helium ionizations in the LIC are compatible with photoionization by the local EUV radiation fields from the hot stars and the cloud interface with the hot gas. We confirm the detection of high ionization species : Si III is detected in all clouds and C IV in two of them, including the LIC, suggesting the presence of ionized interfaces around the local clouds.

  10. Two-particle versus three-particle interactions in single ionization of helium by ion impact

    International Nuclear Information System (INIS)

    Schulz, M; Moshammer, R; Fischer, D; Ullrich, J

    2004-01-01

    We have performed kinematically complete experiments on single ionization of He by 100 MeV amu -1 C 6+ and 3.6 MeV amu -1 Au 24,53+ impact. By analysing doubly differential cross sections (DDCS) as a function of the momenta of all two-particle sub-systems we studied the importance of two-particle interactions. Furthermore, presenting the squared momenta of all three collision fragments simultaneously in a Dalitz plot, we evaluated the role of three-particle interactions. Finally, both for the DDCS and the Dalitz plots the corresponding correlation function was analysed. While the absolute cross sections confirm that ionization predominantly leads to a momentum exchange between the electron and the recoil-ion, the correlation function reveals strong correlations between the particles of any two-particle sub-system. Three-particle correlations, which are not accounted for by perturbative calculations, are quite significant as well, at least for certain kinematic conditions

  11. Complete momentum balance for single ionization of helium by fast ion impact: I. Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Moshammer, R.; Kollmus, H.; Unverzagt, M.; Schmidt-Boecking, H. [Frankfurt Univ. (Germany). Inst. fuer Kernphysik; Ullrich, J.; Schmitt, W. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Wood, C.J.; Olson, R.E. [Missouri Univ., Rolla, MO (United States). Dept. of Physics

    1997-02-01

    The collision dynamics of He single ionization by 3.6 MeV/u Se{sup 28+} impact was explored using the GSI-reaction microscope, a high resolution integrated multi electron - recoil-ion momentum spectrometer. The complete three particle final state momentum distribution (9 cartesian components p{sub i}) was imaged with a resolution of {Delta}p{sub i} {approx} {+-}0.1 a.u. by measuring the three momentum components of the emitted electron and the recoiling target-ion in coincidence. The projectile energy loss has been determined on a level of {Delta}E{sub p}/E{sub p} {approx} 10{sup -7} and projectile scattering angles as small as {Delta}{theta} {approx} 10{sup -7}rad became accessible. The experimental data which are compared with results of classical trajectory Monte-Carlo (CTMC) calculations reveal an unprecedented insight into the details of the electron emission and the collision dynamics for ionization of helium by fast heavy-ion impact. (orig.)

  12. Complete momentum balance for single ionization of helium by fast ion impact: I. Experiment

    International Nuclear Information System (INIS)

    Moshammer, R.; Kollmus, H.; Unverzagt, M.; Schmidt-Boecking, H.; Wood, C.J.; Olson, R.E.

    1997-02-01

    The collision dynamics of He single ionization by 3.6 MeV/u Se 28+ impact was explored using the GSI-reaction microscope, a high resolution integrated multi electron - recoil-ion momentum spectrometer. The complete three particle final state momentum distribution (9 cartesian components p i ) was imaged with a resolution of Δp i ∼ ±0.1 a.u. by measuring the three momentum components of the emitted electron and the recoiling target-ion in coincidence. The projectile energy loss has been determined on a level of ΔE p /E p ∼ 10 -7 and projectile scattering angles as small as Δθ ∼ 10 -7 rad became accessible. The experimental data which are compared with results of classical trajectory Monte-Carlo (CTMC) calculations reveal an unprecedented insight into the details of the electron emission and the collision dynamics for ionization of helium by fast heavy-ion impact. (orig.)

  13. High speed cutting of AZ31 magnesium alloy

    Directory of Open Access Journals (Sweden)

    Liwei Lu

    2016-06-01

    Full Text Available Using LBR-370 numerical control lathe, high speed cutting was applied to AZ31 magnesium alloy. The influence of cutting parameters on microstructure, surface roughness and machining hardening were investigated by using the methods of single factor and orthogonal experiment. The results show that the cutting parameters have an important effect on microstructure, surface roughness and machine hardening. The depth of stress layer, roughness and hardening present a declining tendency with the increase of the cutting speed and also increase with the augment of the cutting depth and feed rate. Moreover, we established a prediction model of the roughness, which has an important guidance on actual machining process of magnesium alloy.

  14. Ionization particle detector

    International Nuclear Information System (INIS)

    Ried, L.

    1982-01-01

    A new device is claimed for detecting particles in a gas. The invention comprises a low cost, easy to assemble, and highly accurate particle detector using a single ionization chamber to contain a reference region and a sensing region. The chamber is designed with the radioactive source near one electrode and the second electrode located at a distance less than the distance of maximum ionization from the radioactive source

  15. Multiple ionization of noble gases by 2.0 MeV proton impact: comparison with equi-velocity electron impact ionization

    International Nuclear Information System (INIS)

    Melo, W.S.; Santos, A.C.F.; Sant'Anna, M.M.; Sigaud, G.M.; Montenegro, E.C.

    2002-01-01

    Absolute single- and multiple-ionization cross sections of rare gases (He, Ne, Ar, Kr and Xe) have been measured for collisions with 2.0 MeV p + . A comparison is made with equi-velocity electron impact ionization cross sections as well as with the available proton impact data. For the light rare gases the single-ionization cross sections are essentially the same for both proton and electron impacts, but increasing differences appear for the heavier targets. (author). Letter-to-the-editor

  16. Magnesium compounds

    Science.gov (United States)

    Kramer, D.A.

    2012-01-01

    Seawater and natural brines accounted for about 57 percent of magnesium compounds produced in the United States in 2011. Dead-burned magnesia was produced by Martin Marietta Magnesia Specialties LLC from well brines in Michigan. Caustic-calcined magnesia was recovered from seawater by Premier Magnesia LLC in Florida, from well brines in Michigan by Martin Marietta and from magnesite in Nevada by Premier Magnesia. Intrepid Potash Wendover LLC and Great Salt Lake Minerals Corp. recovered magnesium chloride brines from the Great Salt Lake in Utah. Magnesium hydroxide was produced from seawater by SPI Pharma Inc. in Delaware and Premier Magnesia in Florida, and by Martin Marietta from its brine operation in Michigan.

  17. Magnesium-based implants: a mini-review.

    Science.gov (United States)

    Luthringer, Bérengère J C; Feyerabend, Frank; Willumeit-Römer, Regine

    2014-01-01

    The goal of this review is to bring to the attention of the readership of Magnesium Research another facet of the importance of magnesium, i.e. magnesium-based biomaterials. A concise history of biomaterials and magnesium are thus presented. In addition, historical and current, clinical magnesium-based applications are presented.

  18. Triple differential cross section for the near threshold single ionization of helium atoms for equal energy sharing

    Energy Technology Data Exchange (ETDEWEB)

    Purohit, G., E-mail: ghanshyam.purohit@spsu.ac.in [Department of Physics, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur 313 601 (India); Singh, P. [Department of Physics, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur 313 601 (India); Dorn, A.; Ren, X. [Max Planck Institute for Nuclear Physics, 69117 Heidelberg (Germany); Patidar, V. [Department of Physics, School of Engineering, Sir Padampat Singhania University, Bhatewar, Udaipur 313 601 (India)

    2016-05-15

    Highlights: • Present paper describes electron impact single ionization of helium atoms near threshold. • This energy range provided challenges to theoretical models due to presence of several physical effects at low energies such as second order processes, PCI, polarization, etc. • Inclusion of second Born term and target polarization is helpful to analyze the measurements. • Present paper also describes usefulness of post collisional interaction in the collision dynamics at low energies. - Abstract: Low energy electron impact single ionization triple differential cross section (TDCS) results are reported for the helium atoms in the threshold regime at 1 eV, 3 eV and 5 eV excess energy. TDCSs are calculated in the doubly symmetric kinematics for the coplanar to perpendicular emission of electrons. Present attempt to calculate TDCS in the second Born approximation and treating target polarization and post collision interaction is helpful to analyze the available measurements. The second order processes, target polarization and post collision interaction (PCI) have been found to be significant in describing the trends of TDCS and helpful to produce reasonably good agreement with measurements.

  19. Triple differential cross section for the near threshold single ionization of helium atoms for equal energy sharing

    International Nuclear Information System (INIS)

    Purohit, G.; Singh, P.; Dorn, A.; Ren, X.; Patidar, V.

    2016-01-01

    Highlights: • Present paper describes electron impact single ionization of helium atoms near threshold. • This energy range provided challenges to theoretical models due to presence of several physical effects at low energies such as second order processes, PCI, polarization, etc. • Inclusion of second Born term and target polarization is helpful to analyze the measurements. • Present paper also describes usefulness of post collisional interaction in the collision dynamics at low energies. - Abstract: Low energy electron impact single ionization triple differential cross section (TDCS) results are reported for the helium atoms in the threshold regime at 1 eV, 3 eV and 5 eV excess energy. TDCSs are calculated in the doubly symmetric kinematics for the coplanar to perpendicular emission of electrons. Present attempt to calculate TDCS in the second Born approximation and treating target polarization and post collision interaction is helpful to analyze the available measurements. The second order processes, target polarization and post collision interaction (PCI) have been found to be significant in describing the trends of TDCS and helpful to produce reasonably good agreement with measurements.

  20. Choline Magnesium Trisalicylate

    Science.gov (United States)

    Choline magnesium trisalicylate is used to relieve the pain, tenderness, inflammation (swelling), and stiffness caused by arthritis and painful ... used to relieve pain and lower fever. Choline magnesium trisalicylate is in a class of nonsteroidal anti- ...

  1. Combustion and extinction of magnesium fires

    International Nuclear Information System (INIS)

    Malet, J.C.; Duverger de Cuy, G.

    1988-01-01

    The studies made in France on magnesium combustion and extinguishing means are associated at the nuclear fuel of the graphite-gas reactor. Safety studies are made for ameliorate our knowledge on: - magnesium combustion - magnesium fire propagation - magnesium fire extinguishing [fr

  2. Magnesium deficiency: What is our status

    Science.gov (United States)

    Low magnesium intake has been implicated in a broad range of cardiometabolic conditions, including diabetes, hypertension, and cardiovascular disease. Dietary magnesium and total body magnesium status have a widely-used but imperfect biomarker in serum magnesium. Despite serum magnesium’s limitation...

  3. Exploring Redox Properties of Aromatic Amino Acids in Water: Contrasting Single Photon vs Resonant Multiphoton Ionization in Aqueous Solutions.

    Science.gov (United States)

    Roy, Anirban; Seidel, Robert; Kumar, Gaurav; Bradforth, Stephen E

    2018-04-12

    Direct measurements of the valence ionization energies and the reorganization energies of the three aromatic amino acids, l-tyrosine, l-tryptophan, and l-phenylalanine, in aqueous solution using the liquid microjet technique and two different photoemission methods-X-ray photoelectron spectroscopy (XPS) at 175 eV photon energy and resonant two-photon ionization (R2PI) using 2 × 267 nm (2 × 4.64 eV) UV laser light-are reported. l-Tryptophan has the lowest vertical ionization energy, 7.3 eV, followed by tyrosine (7.8 eV) and phenylalanine (∼8.7 eV). Essentially, no variation in recovered orbital energies is observed comparing near threshold ionization to X-ray ionization. Superior sensitivity of the (background-free) R2PI scheme for solutions with very low solute concentration (<2 mM) is demonstrated in contrast to the single-photon XPS measurements, which often requires solute concentrations of 0.1-1 molar. This higher sensitivity along with chemical selectivity of the R2PI technique can be exploited for both spectroscopic assignment and as an analytical tool. The nature of the adiabatic ionization energy for the three aromatic amino acids has been explored by the R2PI approach and by empirically formulating the correlation between the estimated ionization onset with electronic and nuclear relaxation on the excited state surface. Our results have implications for understanding one-electron transfer within enzymes and in redox situations where (ir)reversible deprotonation occurs such as those manifest in the biochemistry of oxidation damage.

  4. A new method for grain refinement in magnesium alloy: High speed extrusion machining

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yao, E-mail: liuyao@ustb.edu.cn [School of Mathematics and Physics, University of Science and Technology Beijing, Beijing 100083 (China); Cai, Songlin [China Electric Power Research Institute, State Grid Corporation of China, Beijing 100192 (China); Dai, Lanhong [State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Science, Beijing 100190 (China)

    2016-01-10

    Magnesium alloys have received broad attentions in industry due to their competitive strength to density ratio, but the poor ductility and strength limit their wide range of applications as engineering materials. A novel severe plastic deformation (SPD) technique of high speed extrusion machining (HSEM) was used here. This method could improve the aforementioned disadvantages of magnesium alloys by one single processing step. In this work, systematic HSEM experiments with different chip thickness ratios were conducted for magnesium alloy AZ31B. The microstructure of the chips reveals that HSEM is an effective SPD method for attaining magnesium alloys with different grain sizes and textures. The magnesium alloy with bimodal grain size distribution has increased mechanical properties than initial sample. The electron backscatter diffraction (EBSD) analysis shows that the dynamic recrystallization (DRX) affects the grain refinement and resulting hardness in AZ31B. Based on the experimental observations, a new theoretical model is put forward to describe the effect of DRX on materials during HSEM. Compared with the experimental measurements, the theoretical model is effective to predict the mechanical property of materials after HSEM.

  5. Single-photon double ionization: renormalized-natural-orbital theory versus multi-configurational Hartree–Fock

    International Nuclear Information System (INIS)

    Brics, M; Rapp, J; Bauer, D

    2017-01-01

    The N -particle wavefunction has too many dimensions for a direct time propagation of a many-body system according to the time-dependent Schrödinger equation (TDSE). On the other hand, time-dependent density functional theory (TDDFT) tells us that the single-particle density is, in principle, sufficient. However, a practicable equation of motion for the accurate time evolution of the single-particle density is unknown. It is thus an obvious idea to propagate a quantity which is not as reduced as the single-particle density but less dimensional than the N -body wavefunction. Recently, we have introduced time-dependent renormalized-natural-orbital theory (TDRNOT). TDRNOT is based on the propagation of the eigenfunctions of the one-body reduced density matrix, the so-called natural orbitals. In this paper we demonstrate how TDRNOT is related to the multi-configurational time-dependent Hartree–Fock (MCTDHF) approach. We also compare the performance of MCTDHF and TDRNOT versus the TDSE for single-photon double ionization (SPDI) of a 1D helium model atom. SPDI is one of the effects where TDDFT does not work in practice, especially if one is interested in correlated photoelectron spectra, for which no explicit density functional is known. (paper)

  6. Magnesium Technology : Preface

    NARCIS (Netherlands)

    Sillekens, W.H.; Agnew, S.R.; Neelameggham, N.R.; Mathaudhu, S.N.

    2011-01-01

    The Magnesium Technology Symposium, which takes place every year at the TMS Annual Meeting & Exhibition, is one of the largest yearly gatherings of magnesium specialists in the world. Papers are presented in all aspects of the field, ranging from primary production to applications to recycling.

  7. Ionization detector, electrode configuration and single polarity charge detection method

    Science.gov (United States)

    He, Z.

    1998-07-07

    An ionization detector, an electrode configuration and a single polarity charge detection method each utilize a boundary electrode which symmetrically surrounds first and second central interlaced and symmetrical electrodes. All of the electrodes are held at a voltage potential of a first polarity type. The first central electrode is held at a higher potential than the second central or boundary electrodes. By forming the first and second central electrodes in a substantially interlaced and symmetrical pattern and forming the boundary electrode symmetrically about the first and second central electrodes, signals generated by charge carriers are substantially of equal strength with respect to both of the central electrodes. The only significant difference in measured signal strength occurs when the charge carriers move to within close proximity of the first central electrode and are received at the first central electrode. The measured signals are then subtracted and compared to quantitatively measure the magnitude of the charge. 10 figs.

  8. The Corrosion of Magnesium and of the Magnesium Aluminum Alloys Containing Manganese

    Science.gov (United States)

    Boyer, J A

    1927-01-01

    The extensive use of magnesium and its alloys in aircraft has been seriously handicapped by the uncertainties surrounding their resistance to corrosion. This problem has been given intense study by the American Magnesium Corporation and at the request of the Subcommittee on Materials for Aircraft of the National Advisory Committee for Aeronautics this report was prepared on the corrosion of magnesium. The tentative conclusions drawn from the experimental facts of this investigation are as follows: the overvoltage of pure magnesium is quite high. On immersion in salt water the metal corrodes with the liberation of hydrogen until the film of corrosion product lowers the potential to a critical value. When the potential reaches this value it no longer exceeds the theoretical hydrogen potential plus the overvoltage of the metal. Rapid corrosion consequently ceases. When aluminum is added, especially when in large amounts, the overvoltage is decreased and hydrogen plates out at a much lower potential than with pure magnesium. The addition of small amount of manganese raises the overvoltage back to practically that of pure metal, and the film is again negative.

  9. Design of the Intravenous Magnesium Efficacy in Acute Stroke (IMAGES) trial [ISRCTN19943732

    OpenAIRE

    Bradford, Andrew; Lees, Kennedy

    2000-01-01

    Abstract The Intravenous Magnesium Efficacy in Acute Stroke (IMAGES) trial is a multicentre,randomised, placebo-controlled trial of magnesium sulphate (MgSO4) funded by the UK Medical Research Council. When complete, it will be the largest single neuroprotective study undertaken to date. Conscious patients presenting within 12 h of acute stroke with limb weakness are eligible. The primary outcome measure is combined death and disability as measured using the Barthel Index at 90-day follow up....

  10. One color multi-photon ionization of the Gadolinium atom in near UV region

    International Nuclear Information System (INIS)

    Kim, Jin Tae; Yi, Jong Hoon; Lhee, Yong Joo; Lee, Jong Min

    1999-01-01

    We have investigated the states of the gadolinium atom in near ultra-violet (UV) region (∼410 nm) using single photon excitation using resonance ionization mass spectrometry (RIMS). Around 70 transitions among observed 180 single color multi-photon ionization signals have been assigned. Most of the multi-photon processes of the assigned ion signals are through single photon resonant three photon ionization and through two photon resonant three photon ionization. (author)

  11. Differential cross sections for single ionization of H2 by 75keV proton impact

    International Nuclear Information System (INIS)

    Chowdhury, U; Schulz, M; Madison, D H

    2012-01-01

    We have calculated Triply differential cross sections (TDCS) and doubly differential cross sections (DDCS) for single ionization of H 2 by 75 keV proton impact using the molecular 3 body distorted wave Eikonal initial state (M3DW-EIS) approach. Previously published measured DDCS-P (differential in the projectile scattering angle and integrated over the ejected electron angles) found pronounced structures at relatively large angles which were interpreted as an interference resulting from the two-centered potential of the molecule.

  12. Photoluminescence of magnesium-associated color centers in LiF crystals implanted with magnesium ions

    Science.gov (United States)

    Nebogin, S. A.; Ivanov, N. A.; Bryukvina, L. I.; V. Shipitsin, N.; E. Rzhechitskii, A.; Papernyi, V. L.

    2018-05-01

    In the present paper, the effect of magnesium nanoparticles implanted in a LiF crystal on the optical properties of color centers is studied. The transmittance spectra and AFM images demonstrate effective formation of the color centers and magnesium nanoparticles in an implanted layer of ∼ 60-100 nm in thickness. Under thermal annealing, a periodical structure is formed on the surface of the crystal and in the implanted layer due to self-organization of the magnesium nanoparticles. Upon excitation by argon laser with a wavelength of 488 nm at 5 K, in a LiF crystal, implanted with magnesium ions as well as in heavily γ-irradiated LiF: Mg crystals, luminescence of the color centers at λmax = 640 nm with a zero-phonon line at 601.5 nm is observed. The interaction of magnesium nanoparticles and luminescing color centers in a layer implanted with magnesium ions has been revealed. It is shown that the luminescence intensity of the implanted layer at a wavelength of 640 nm is by more than two thousand times higher than that of a heavily γ-irradiated LiF: Mg crystal. The broadening of the zero-phonon line at 601.5 nm in the spectrum of the implanted layer indicates the interaction of the emitting quantum system with local field of the surface plasmons of magnesium nanoparticles. The focus of this work is to further optimize the processing parameters in a way to result in luminescence great enhancement of color centers by magnesium nanoparticles in LiF.

  13. Magnesium oxychloride cement concrete

    Indian Academy of Sciences (India)

    TECS

    exposure to water and salt attack by replacing 10% magnesium chloride solution by magnesium sulphate solution ... Having tremendous load bearing capacity, it can withstand .... retention coefficients for similar concrete compositions.

  14. 21 CFR 184.1443 - Magnesium sulfate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium sulfate. 184.1443 Section 184.1443 Food... Specific Substances Affirmed as GRAS § 184.1443 Magnesium sulfate. (a) Magnesium sulfate (MgSO4·7H2O, CAS... magnesium oxide, hydroxide, or carbonate with sulfuric acid and evaporating the solution to crystallization...

  15. Mineral resource of the month: magnesium

    Science.gov (United States)

    Kramer, Deborah A.

    2012-01-01

    Magnesium is the eighthmost abundant element in Earth’s crust, and the second-most abundant metal ion in seawater. Although magnesium is found in more than 60 minerals, only brucite, dolomite, magnesite and carnallite are commercially important for their magnesium content. Magnesium and its compounds also are recovered from seawater, brines found in lakes and wells, and bitterns (salts).

  16. 21 CFR 184.1431 - Magnesium oxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium oxide. 184.1431 Section 184.1431 Food and... Substances Affirmed as GRAS § 184.1431 Magnesium oxide. (a) Magnesium oxide (MgO, CAS Reg. No. 1309-48-4... powder (light) or a relatively dense white powder (heavy) by heating magnesium hydroxide or carbonate...

  17. 21 CFR 184.1426 - Magnesium chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Magnesium chloride. 184.1426 Section 184.1426 Food... Specific Substances Affirmed as GRAS § 184.1426 Magnesium chloride. (a) Magnesium chloride (MgC12·6H2O, CAS... hydrochloric acid solution and crystallizing out magnesium chloride hexahydrate. (b) The ingredient meets the...

  18. A comparative study of the ignition and burning characteristics of after burning aluminum and magnesium particles

    International Nuclear Information System (INIS)

    Lim, Ji Hwan; Lee, Sang Hyup; Yoon, Woong Sup

    2014-01-01

    Ignition and the burning of air-born single aluminum and magnesium particles are experimentally investigated. Particles of 30 to 106 μm-diameters were electrodynamically levitated, ignited, and burnt in atmospheric air. The particle combustion evolution was recorded by high-speed cinematography. Instant temperature and thermal radiation intensity were measured using two-wavelength pyrometry and photomultiplier tube methods. Ignition of the magnesium particle is prompt and substantially advances the aluminum particle by 10 ms. Burning time of the aluminum particles is extended 3 to 5 times longer than the magnesium particles. Exponents of a power-law fit of the burning rates are 1.55 and 1.24 for aluminum and magnesium particles, respectively. Flame temperature is slightly lower than the oxide melting temperature. For the aluminum, dimensionless flame diameter is inert to the initial particle size, but for the magnesium inversely proportional to the initial diameter.

  19. A comparative study of the ignition and burning characteristics of after burning aluminum and magnesium particles

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Ji Hwan; Lee, Sang Hyup; Yoon, Woong Sup [Yonsei University, Seoul (Korea, Republic of)

    2014-10-15

    Ignition and the burning of air-born single aluminum and magnesium particles are experimentally investigated. Particles of 30 to 106 μm-diameters were electrodynamically levitated, ignited, and burnt in atmospheric air. The particle combustion evolution was recorded by high-speed cinematography. Instant temperature and thermal radiation intensity were measured using two-wavelength pyrometry and photomultiplier tube methods. Ignition of the magnesium particle is prompt and substantially advances the aluminum particle by 10 ms. Burning time of the aluminum particles is extended 3 to 5 times longer than the magnesium particles. Exponents of a power-law fit of the burning rates are 1.55 and 1.24 for aluminum and magnesium particles, respectively. Flame temperature is slightly lower than the oxide melting temperature. For the aluminum, dimensionless flame diameter is inert to the initial particle size, but for the magnesium inversely proportional to the initial diameter.

  20. Lightweight Heat Pipes Made from Magnesium

    Science.gov (United States)

    Rosenfeld, John N.; Zarembo, Sergei N.; Eastman, G. Yale

    2010-01-01

    Magnesium has shown promise as a lighter-weight alternative to the aluminum alloys now used to make the main structural components of axially grooved heat pipes that contain ammonia as the working fluid. Magnesium heat-pipe structures can be fabricated by conventional processes that include extrusion, machining, welding, and bending. The thermal performances of magnesium heat pipes are the same as those of equal-sized aluminum heat pipes. However, by virtue of the lower mass density of magnesium, the magnesium heat pipes weigh 35 percent less. Conceived for use aboard spacecraft, magnesium heat pipes could also be attractive as heat-transfer devices in terrestrial applications in which minimization of weight is sought: examples include radio-communication equipment and laptop computers.

  1. 21 CFR 862.1495 - Magnesium test system.

    Science.gov (United States)

    2010-04-01

    ... magnesium levels in serum and plasma. Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low plasma levels of magnesium) and hypermagnesemia (abnormally high plasma levels of magnesium). (b) Classification. Class I. ...

  2. Measured, calculated and predicted Stark widths of the singly ionized C, N, O, F, Ne, Si, P, S, Cl and Ar spectral lines

    Directory of Open Access Journals (Sweden)

    Djeniže S.

    2000-01-01

    Full Text Available In order to find reliable Stark width data, needed in plasma spectroscopy comparision between the existing measured, calculated and predicted Stark width values was performed for ten singly ionized emitters: C, N, O, F, Ne Si, P, S, Cl and Ar in the lower lying 3s - 3p, 3p - 3d and 4s - 4p transitions. These emitters are present in many cosmic light sources. On the basis of the agreement between mentioned values 17 spectral lines from six singly ionized spectra have been recommended, for the first time, for plasma spectroscopy as spectral lines with reliable Stark width data. Critical analysis of the existing Stark width data is also given.

  3. Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser

    DEFF Research Database (Denmark)

    He, Ming; Jensen, Brian B; Therkildsen, Kasper T

    2009-01-01

    We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we obta...... obtained more than 40 mW of 517 nm output power by single pass frequency doubling. In addition, fluorescence spectroscopy of metastable magnesium atoms could be used to stabilize the 517 nm laser to an absolute frequency within 1 MHz.......We present a laser operating at 517 nm for our Magnesium laser-cooling and atomic clock project. A two-stage Yb-doped fiber amplifier (YDFA) system generates more than 1.5 W of 1034 nm light when seeded with a 15 mW diode laser. Using a periodically poled lithium niobate (PPLN) waveguide, we...

  4. Radioactive 210Po in magnesium supplements

    International Nuclear Information System (INIS)

    Struminska-Parulska, Dagmara Ida

    2016-01-01

    The aim of this pioneer study was to determine polonium 210 Po in the most popular magnesium supplements in Poland and estimate the possible related dose assessment to the consumers. The analyzed magnesium pharmaceutics contained organic or inorganic magnesium compounds; some from natural sources. The objectives of this research were to investigate the naturally occurring 210 Po activity concentrations in magnesium supplements, find the correlations between 210 Po concentration in medicament and magnesium chemical form, and calculate the effective radiation dose connected to analyzed magnesium supplement consumption. The highest 210 Po activity concentrations were determined in mineral tablets made from sedimentary rocks, namely dolomite - 3.84 ± 0.15 mBq g -1 (sample Mg17). The highest annual radiation dose from 210 Po taken with 1 tablet of magnesium supplement per day or with 400 mg of pure Mg daily would come from sample Mg17 (dolomite) - 1.35 ± 0.5 and 8.44 ± 0.33 μSv year -1 respectively.

  5. Alkoxide-based magnesium electrolyte compositions for magnesium batteries

    Science.gov (United States)

    Dai, Sheng; Sun, Xiao-Guang; Liao, Chen; Guo, Bingkun

    2018-01-30

    Alkoxide magnesium halide compounds having the formula: RO--Mg--X (1) wherein R is a saturated or unsaturated hydrocarbon group that is unsubstituted, or alternatively, substituted with one or more heteroatom linkers and/or one or more heteroatom-containing groups comprising at least one heteroatom selected from fluorine, nitrogen, oxygen, sulfur, and silicon; and X is a halide atom. Also described are electrolyte compositions containing a compound of Formula (1) in a suitable polar aprotic or ionic solvent, as well as magnesium batteries in which such electrolytes are incorporated.

  6. Corrosion resistance of multilayered magnesium phosphate/magnesium hydroxide film formed on magnesium alloy using steam-curing assisted chemical conversion method

    International Nuclear Information System (INIS)

    Ishizaki, Takahiro; Kudo, Ruriko; Omi, Takeshi; Teshima, Katsuya; Sonoda, Tsutomu; Shigematsu, Ichinori; Sakamoto, Michiru

    2012-01-01

    Anticorrosive multilayered films were successfully prepared on magnesium alloy AZ31 by chemical conversion treatment, followed by steam curing treatment. The crystal structures, chemical composition, surface morphologies, chemical bonding states of the film was characterized using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and field emission scanning electron microscope (FE-SEM) measurements. All the films had thicknesses of ranging from 24 to 32 μm. The film had two layers that were composed of crystalline NH 4 MgPO 4 ·H 2 O, Mg 2 PO 4 OH·3H 2 O, Mg(OH) 2 and amorphous MgO. The outer layers include magnesium, oxygen, and phosphorous, and the inner layers include magnesium and oxygen. The corrosion resistant performances of the multilayered films in 5 wt% NaCl aqueous solution were investigated by electrochemical and gravimetric measurements. The potentiodynamic polarization curves revealed that the corrosion current density (j corr ) of all the film coated magnesium alloys decreased by more than four orders of magnitude as compared to that of the bare magnesium alloy, indicating that all the films had an inhibiting effect of corrosion reaction. Gravimetric measurements showed that the average corrosion rates obtained from the weight loss rates were estimated to be in the ranges of ca. 0.085–0.129 mm/y. American Society for Testing and Materials (ASTM) standard D 3359-02 cross cut tape test revealed that the adhesion of our anticorrosive multilayered film to the magnesium alloy surface was very good.

  7. Nanostructured magnesium increases bone cell density.

    Science.gov (United States)

    Weng, Lucy; Webster, Thomas J

    2012-12-07

    Magnesium has attracted some attention in orthopedics due to its biodegradability and mechanical properties. Since magnesium is an essential natural mineral for bone growth, it can be expected that as a biomaterial, it would support bone formation. However, upon degradation in the body, magnesium releases OH(-) which results in an alkaline pH that can be detrimental to cell density (for example, osteoblasts or bone forming cells). For this reason, modification of magnesium may be necessary to compensate for such detrimental effects to cells. This study created biologically inspired nanoscale surface features on magnesium by soaking magnesium in various concentrations of NaOH (from 1 to 10 N) and for various periods of time (from 10 to 30 min). The results provided the first evidence of increased roughness, surface energy, and consequently greater osteoblast adhesion, after 4 h as well as density up to 7 days on magnesium treated with any concentration of NaOH for any length of time compared to untreated controls. For these reasons, this study suggests that soaking magnesium in NaOH could be an inexpensive, simple and effective manner to promote osteoblast functions for numerous orthopedic applications and, thus, should be further studied.

  8. Calcium and magnesium determination

    International Nuclear Information System (INIS)

    Bhattacharya, S.K.

    1982-01-01

    The roles of calcium and magnesium in human health and disease have been extensively studied. Calcium and magnesium have been determined in biological specimens by atomic absorption spectroscopy using stiochiometric nitrous oxide-acetylene flame

  9. Multiple ionization of atoms by ion impact

    International Nuclear Information System (INIS)

    DuBois, R.D.

    1988-01-01

    In order to model the energy deposition of fast ions as they slow down in gaseous media, information about the ionization occurring in collisions between ions and target atoms/molecules is required. Our measurements of doubly differential electron emission cross sections provide detailed information about the ionization process but do not provide any information about the final states of the target. They also do not distinguish between the emission of one or more target electrons in a single collision. It is important to know the relative importance of multiple-, with respect to single-, target ionization in order to accurately model the energy deposition. To date, multiple ionization of He, Ne, Ar, Kr, and Xe targets has been studied. Primarily, H and He ions were used, although some data for heavier ions (C,N and O) have also been obtained

  10. Magnesium, calcium and phosphorus in the intensive care unit: Do ...

    African Journals Online (AJOL)

    Magnesium, calcium and phosphorus are important electrolytes involved in the regulation of homeostasis. However the utility in monitoring them in critically ill patients is still unclear. We therefore undertook a prospective, non-interventional, single center study in the intensive care unit of a tertiary care hospital in ...

  11. A SEARCH FOR MAGNESIUM IN EUROPA'S ATMOSPHERE

    International Nuclear Information System (INIS)

    Hörst, S. M.; Brown, M. E.

    2013-01-01

    Europa's tenuous atmosphere results from sputtering of the surface. The trace element composition of its atmosphere is therefore related to the composition of Europa's surface. Magnesium salts are often invoked to explain Galileo Near Infrared Mapping Spectrometer spectra of Europa's surface, thus magnesium may be present in Europa's atmosphere. We have searched for magnesium emission in the Hubble Space Telescope Faint Object Spectrograph archival spectra of Europa's atmosphere. Magnesium was not detected and we calculate an upper limit on the magnesium column abundance. This upper limit indicates that either Europa's surface is depleted in magnesium relative to sodium and potassium, or magnesium is not sputtered as efficiently resulting in a relative depletion in its atmosphere.

  12. Corrosion of magnesium and some magnesium alloys in gas cooled reactors

    International Nuclear Information System (INIS)

    Caillat, R.; Darras, R.

    1958-01-01

    The results of corrosion tests on magnesium and some magnesium alloys (Mg-Zr and Mg-Zr-Zn) in moist air (like G1 reactor) and in CO 2 : (like G2, G3, EDF1 reactors) are reported. The maximum temperature for exposure of magnesium to moist air without any risk of corrosion is 350 deg. C. Indeed, the oxidation rate follows a linear law above 350 deg. C although it reaches a constant level and keeps on very low under 350 deg. C. However, as far as corrosion is concerned this temperature limit can be raised up to 500 deg. C if moist air is very slightly charged with fluorinated compounds. Under pressure of CO 2 , these three materials oxidate much more slowly even if 500 deg. C is reached. The higher is the temperature, the higher is the constant level of the weight increase and the quicker is reached this one. However, Mg-Zr alloy behaves quite better than pure magnesium and especially than Mg-Zr-Zn alloy. (author) [fr

  13. Nanostructured magnesium increases bone cell density

    International Nuclear Information System (INIS)

    Weng, Lucy; Webster, Thomas J

    2012-01-01

    Magnesium has attracted some attention in orthopedics due to its biodegradability and mechanical properties. Since magnesium is an essential natural mineral for bone growth, it can be expected that as a biomaterial, it would support bone formation. However, upon degradation in the body, magnesium releases OH − which results in an alkaline pH that can be detrimental to cell density (for example, osteoblasts or bone forming cells). For this reason, modification of magnesium may be necessary to compensate for such detrimental effects to cells. This study created biologically inspired nanoscale surface features on magnesium by soaking magnesium in various concentrations of NaOH (from 1 to 10 N) and for various periods of time (from 10 to 30 min). The results provided the first evidence of increased roughness, surface energy, and consequently greater osteoblast adhesion, after 4 h as well as density up to 7 days on magnesium treated with any concentration of NaOH for any length of time compared to untreated controls. For these reasons, this study suggests that soaking magnesium in NaOH could be an inexpensive, simple and effective manner to promote osteoblast functions for numerous orthopedic applications and, thus, should be further studied. (paper)

  14. Ionizing and non-ionizing radiations

    International Nuclear Information System (INIS)

    1994-01-01

    The monograph is a small manual to get a knowledge of ionizing and non-ionizing radiations. The main chapters are: - Electromagnetic radiations - Ionizing and non-ionizing radiations - Non-ionizing electromagnetic radiations - Ionizing electromagnetic radiation - Other ionizing radiations - Ionizing radiation effects - The Nuclear Safety Conseil

  15. CDW-EIS theoretical calculations of projectile deflection for single ionization in highly charged ion-atom collisions

    International Nuclear Information System (INIS)

    Rodriguez, V.D.

    2003-01-01

    We present continuum distorted wave-eikonal initial state (CDW-EIS) theoretical calculations for the projectile deflection in single ionization of helium by heavy-ion impact as a function of ionized electron energies. These calculations account for the helium passive electron shielding in the internuclear interaction improving standard CDW-EIS theory. The results are compared with recent experimental results by impact of 100 MeV/amu C 6+ and 3.6 MeV/amu Au 53+ . For highly charged projectiles there is a poor quantitative agreement between theory and experiment. However, this refined calculation does share some qualitative features with the data. In particular the variation of the effective charge of the residual He + ion from Z eff =1 to Z eff =2 when going from small to large projectile scattering angles is able to represent a shoulder observed in the double differential cross sections. Important qualitative differences are observed at the level of triple differential cross sections

  16. Comparison of Bupivacaine Plus Magnesium Sulfate and Ropivacaine Plus Magnesium Sulfate Infiltration for Postoperative Analgesia in Patients Undergoing Lumbar Laminectomy: A Randomized Double-blinded Study.

    Science.gov (United States)

    Hazarika, Rajib; Parua, Samit; Choudhury, Dipika; Barooah, Rajesh Kumar

    2017-01-01

    The objective of this study was to assess and compare the analgesic duration of local infiltration of bupivacaine plus magnesium sulfate and ropivacaine plus magnesium sulfate for postoperative analgesia in patients undergoing lumbar laminectomy. A randomized, prospective, double-blinded single hospital, comparative study. Sixty adult patients of the American Society of Anesthesiologists physical Status I and II were randomly allocated into two Groups BM and RM, comprising 30 and 31 patients. Postlumbar laminectomy, the study drug was locally infiltrated into the paravertebral muscles on either side before skin closure. Group BM was given 20 ml of 0.25% bupivacaine combined with 500 mg of magnesium sulfate (constituted with normal saline [NS]), and Group RM was given 20 ml of 0.25% ropivacaine combined with 500 mg of magnesium sulfate (constituted with NS). Postoperative visual analog scale pain score was assessed hourly for the first 24 h postoperatively. Duration of postoperative analgesia, rescue analgesia consumption and side effects were also recorded. Comparison of data between the groups was done with SPSS 21.0© using independent t -test, Chi-square test, and Mann-Whitney U-test accordingly. P <0.05 was considered statistically significant. Time to first analgesic consumption was significantly longer in Group BM (7.3 ± 0.46 h) compared to Group RM (6.6 ± 0.69 h) ( P < 0.05). The consumption of nalbuphine rescue analgesic was significantly higher in Group RM (15.33 ± 5.07 mg) compared to Group BM (12 ± 4.07 mg) ( P < 0.05). Wound infiltration with bupivacaine and magnesium sulfate compared to ropivacaine and magnesium sulfate provided longer duration of postoperative analgesia and significantly reduced postoperative opioid consumption in patients undergoing lumbar laminectomy.

  17. Nutrition and magnesium absorption

    NARCIS (Netherlands)

    Brink, E.J.

    1992-01-01

    The influence of various nutrients present in dairy products and soybean-based products on absorption of magnesium has been investigated. The studies demonstrate that soybean protein versus casein lowers apparent magnesium absorption in rats through its phytate component. However, true

  18. Many-electron phenomena in the ionization of ions

    International Nuclear Information System (INIS)

    Mueller, A.

    2004-01-01

    Full text: Single and multiple ionization in ion-atom collisions involve a multitude of complex interactions between the electrons and nuclei of projectile and target. Some of the complexity is avoided in studies of fast collisions when the impulse approximation can be applied and the electrons can be described as independent quasi-free particles with a known momentum distribution. For the detailed investigation of ionization mechanisms that can occur in fast ion-atom collisions, it is illuminating to consider collisions of ions (or atoms) and really free electrons with a narrow energy spread. High energy resolution in electron-ion collision studies provides access to individual, possibly even state-selective, reaction pathways. Even in the simple electron-ion collision system (simple compared with the initial ion-atom problem) single and multiple ionization still involve a multitude of complex mechanisms. Besides the direct removal of one or several electrons from the target by electron impact, resonant and non-resonant formation of intermediate multiply excited states which subsequently decay by electron emission is important in single and multiple ionization of ions and atoms. Direct ionization proceeds via one-step or multi-step knock-off mechanisms which can partly be disentangled by studying effects of different projectile species. The role of multiply excited states in the ionization can be experimentally studied in great detail by a further reduction of the initial ion-atom problem. Multiply excited states of atoms and ions can be selectively populated by photon-ion interactions making use of the potential for extreme energy resolution made available at modern synchrotron radiation sources. In the review talk, examples of studies on single and multiple ionization in electron-ion collisions will be discussed in some detail. Electron-ion collision experiments will also be compared with photon-ion interaction studies. Many-electron phenomena have been observed

  19. Magnesium-DNA interactions and the possible relation of magnesium to carcinogenesis. Irradiation and free radicals.

    Science.gov (United States)

    Anastassopoulou, J; Theophanides, T

    2002-04-01

    Magnesium deficiency causes renal complications. The appearance of several diseases is related to its depletion in the human body. In radiotherapy, as well as in chemotherapy, especially in treatment of cancers with cis-platinum, hypomagnesaemia is observed. The site effects of chemotherapy that are due to hypomagnesaemia are decreased using Mg supplements. The role of magnesium in DNA stabilization is concentration dependent. At high concentrations there is an accumulation of Mg binding, which induces conformational changes leading to Z-DNA, while at low concentration there is deficiency and destabilization of DNA. The biological and clinical consequences of abnormal concentrations are DNA cleavage leading to diseases and cancer. Carcinogenesis and cell growth are also magnesium-ion concentration dependent. Several reports point out that the interaction of magnesium in the presence of other metal ions showed that there is synergism with Li and Mn, but there is magnesium antagonism in DNA binding with the essential metal ions in the order: Zn>Mg>Ca. In the case of toxic metals such as Cd, Ga and Ni there is also antagonism for DNA binding. It was found from radiolysis of deaerated aqueous solutions of the nucleoside 5'-guanosine monophosphate (5'-GMP) in the presence as well as in the absence of magnesium ions that, although the addition of hydroxyl radicals (*OH) has been increased by 2-fold, the opening of the imidazole ring of the guanine base was prevented. This effect was due to the binding of Mg2+ ions to N7 site of the molecule by stabilizing the five-member ring imitating cis-platinum. It was also observed using Fourier Transform Infrared spectroscopy, Raman spectroscopy and Fast Atom Bombardment mass spectrometry that *OH radicals subtract H atoms from the C1', C4' and C5' sites of the nucleotide. Irradiation of 5'-GMP in the presence of oxygen (2.5 x 10(-4) M) shows that magnesium is released from the complex. There is spectroscopic evidence that

  20. Effect of magnesium and of some trace elements on 14C incorporation in leaf sugars and amino acids of maize plants recovering after magnesium deficit stress

    International Nuclear Information System (INIS)

    Chichev, P.; Stoyanov, I.; Tungarov, G.

    1977-01-01

    The incorporation and distribution of 14 C in leaf free sugars and amino acids of maize plants under magnesium deficiency and following their recovery was studied by the aid of Mg applied singly or in combination with the trace elements Co, Cr, and B. It was established that stress resulting from magnesium deficit causes considerable changes in free sugar and amino acid metabolism. Magnesium deficiency reduces the relative share of sugars and raises the share of amino acids. It leads to great changes also in the ratio of the individual substances - reduces succrose, glutamic acid, and -amino butyric acid, increases fructose, rafinose, glucose, alanine, aspartic acid and valine. During a 10-day period of plant recovery the metabolic changes of free sugars and amino acids occurring as a result of magnesium deficit are restored to normal condition. Under the conditions existing in this experiment Mg was capable to restore alone disturbances in free sugar and amino acid metabolism to the level observed in the control plants. The trace elements Co, Cr and B, used in combination with Mg, had no marked additive effect on the recovery process of free sugar and amino acid metabolic disturbances caused by Mg deficiency. (author)

  1. Porous bioresorbable magnesium as bone substitute

    Energy Technology Data Exchange (ETDEWEB)

    Wen, C.E.; Yamada, Y.; Shimojima, K.; Chino, Y.; Hosokawa, H.; Mabuchi, M. [Inst. for Structural and Engineering Materials, National Inst. of Advanced Industrial Science and Technology, Nagoya (Japan)

    2003-07-01

    Recently magnesium has been recognized as a very promising biomaterial for bone substitutes because of its excellent properties of biocompatibility, biodegradability and bioresorbability. In the present study, magnesium foams were fabricated by using a powder metallurgical process. Scanning electron microscopy equipped with energy dispersive X-ray spectrometer (EDS) and compressive tester were used to characterize the porous magnesium. Results show that the Young's modulus and the peak stress of the porous magnesium increase with decreasing porosity and pore size. This study suggests that the mechanical properties of the porous magnesium with the low porosity of 35% and/or with the small pore size of about 70 {mu}m are close to those of human cancellous bones. (orig.)

  2. Small for Gestational Age and Magnesium: Intrauterine magnesium deficiency may induce metabolic syndrome in later life

    Directory of Open Access Journals (Sweden)

    Junji Takaya

    2015-12-01

    Full Text Available Magnesium deficiency during pregnancy as a result of insufficient or low intake of magnesium is common in developing and developed countries. Previous reports have shown that intracellular magnesium of cord blood platelets is lower among small for gestational age (SGA groups than that of appropriate for gestational age (AGA groups, suggesting that intrauterine magnesium deficiency may result in SGA. Additionally, the risk of adult-onset diseases such as insulin resistance syndrome is greater among children whose mothers were malnourished during pregnancy, and who consequently had a low birth weight. In a number of animal models, poor nutrition during pregnancy leads to offspring that exhibit pathophysiological changes similar to human diseases. The offspring of pregnant rats fed a magensium restricted diet have developed hypermethylation in the hepatic 11β-hydroxysteroid dehydrogenase-2 promoter. These findings indicate that maternal magnesium deficiencies during pregnancy influence regulation of non-imprinted genes by altering the epigenetic regulation of gene expression, thereby inducing different metabolic phenotypes. Magnesium deficiency during pregnancy may be responsible for not only maternal and fetal nutritional problems, but also lifelong consequences that affect the offspring throughout their life. Epidemiological, clinical, and basic research on the effects of magnesium deficiency now indicates underlying mechanisms, especially epigenetic processes.

  3. Magnesium in Prevention and Therapy

    Science.gov (United States)

    Gröber, Uwe; Schmidt, Joachim; Kisters, Klaus

    2015-01-01

    Magnesium is the fourth most abundant mineral in the body. It has been recognized as a cofactor for more than 300 enzymatic reactions, where it is crucial for adenosine triphosphate (ATP) metabolism. Magnesium is required for DNA and RNA synthesis, reproduction, and protein synthesis. Moreover, magnesium is essential for the regulation of muscular contraction, blood pressure, insulin metabolism, cardiac excitability, vasomotor tone, nerve transmission and neuromuscular conduction. Imbalances in magnesium status—primarily hypomagnesemia as it is seen more common than hypermagnesemia—might result in unwanted neuromuscular, cardiac or nervous disorders. Based on magnesium’s many functions within the human body, it plays an important role in prevention and treatment of many diseases. Low levels of magnesium have been associated with a number of chronic diseases, such as Alzheimer’s disease, insulin resistance and type-2 diabetes mellitus, hypertension, cardiovascular disease (e.g., stroke), migraine headaches, and attention deficit hyperactivity disorder (ADHD). PMID:26404370

  4. Corrosion of Magnesium in Multimaterial System

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Vineet V.; Agnew, Sean

    2017-08-16

    The TMS Magnesium Committee has been actively involved in presenting cutting-edge research and development and the latest trends related to magnesium and its alloys to industry and academia. Topics including magnesium alloy development, applications, mechanism of deformation and corrosion, thermomechanical processing, modelling, etc. have been captured year after year through the Magnesium Technology symposium and conference proceedings at TMS and through special topics in JOM. Every year, based on the unanimous endorsement from the industry and academia, a topic is selected to address the latest developments within this subject in JOM. In continuation with last year’s coverage of Advances and Achievements in In-Situ Analysis of Corrosions and Structure–Property Relationship in Mg Alloys,[1] this year’s topic focuses on the Corrosion of Magnesium in Multimaterial Systems. Magnesium, the lightest of all the structural materials, has garnered much interest in the transportation, electronics packaging, defense equipments and industries alike and are more commonly being incorporated in multimaterial design concepts.[2-4] However, the application of the same is limited due to its highly corrosive nature, and understanding and mitigating the corrosion of magnesium has been a major research challenge.

  5. First principles electron-correlated calculations of optical absorption in magnesium clusters★

    Science.gov (United States)

    Shinde, Ravindra; Shukla, Alok

    2017-11-01

    In this paper, we report large-scale configuration interaction (CI) calculations of linear optical absorption spectra of various isomers of magnesium clusters Mgn (n = 2-5), corresponding to valence transitions. Geometry optimization of several low-lying isomers of each cluster was carried out using coupled-cluster singles doubles (CCSD) approach, and these geometries were subsequently employed to perform ground and excited state calculations using either the full-CI (FCI) or the multi-reference singles-doubles configuration interaction (MRSDCI) approach, within the frozen-core approximation. Our calculated photoabsorption spectrum of magnesium dimer (Mg2) is in excellent agreement with the experiments both for peak positions, and intensities. Owing to the sufficiently inclusive electron-correlation effects, these results can serve as benchmarks against which future experiments, as well as calculations performed using other theoretical approaches, can be tested. Supplementary material in the form of one pdf fille available from the Journal web page at http://https://doi.org/10.1140/epjd/e2017-80356-6.

  6. The reference range of serum, plasma and erythrocyte magnesium

    Directory of Open Access Journals (Sweden)

    Suzanna Immanuel

    2006-12-01

    Full Text Available The interest in the clinical importance of serum magnesium level has just recently begun with the analysis and findings of abnormal magnesium level in cardiovascular, metabolic and neuromuscular disorder. Although the serum level does not reflect the body magnesium level, but currently, only serum magnesium determination is widely used. Erythrocyte magnesium is considered more sensitive than serum magnesium as it reflects intracellular magnesium status. According to NCCLS (National Committee for Clinical Laboratory Standards every laboratory is recommended to have its own reference range for the tests it performs, including magnesium determination. The reference range obtained is appropriate for the population and affected by the method and technique. This study aimed to find the reference range of serum and plasma magnesium and also intracellular magnesium i.e. erythrocyte magnesium by direct method, and compare the results of serum and plasma magnesium. Blood was taken from 114-blood donor from Unit Transfusi Darah Daerah (UTDD Budhyarto Palang Merah Indonesia (PMI DKI Jakarta, consisted of 57 male and 57 female, aged 17 – 65 years, clinically healthy according to PMI donor criteria. Blood was taken from blood set, collected into 4 ml vacuum tube without anticoagulant for serum magnesium determination and 3 ml vacuum tube with lithium heparin for determination of erythrocyte and plasma magnesium Determination of magnesium level was performed with clinical chemistry auto analyzer Hitachi 912 by Xylidil Blue method colorimetrically. This study showed no significant difference between serum and heparinized plasma extra cellular magnesium. The reference range for serum or plasma magnesium was 1.30 – 2.00 mEq/L and for erythrocyte magnesium was 4.46 - 7.10 mEq/L. (Med J Indones 2006; 15:229-35Keywords: Reference range, extracellular magnesium, intracellular magnesium

  7. Magnesium Tube Hydroforming

    International Nuclear Information System (INIS)

    Liewald, M.; Pop, R.; Wagner, S.

    2007-01-01

    Magnesium alloys can be considered as alternative materials towards achieving light weight structures with high material stiffness. The formability of two magnesium alloys, viz. AZ31 and ZM21 has been experimentally tested using the IHP forming process. A new die set up for hot IHP forming has been designed and the process experimentally investigated for temperatures up to 400 deg. C. Both alloys exhibit an increase in formability with increasing forming temperature. The effect of annealing time on materials forming properties shows a fine grained structure for sufficient annealing times as well as deterioration with a large increase at the same time. The IHP process has also been used to demonstrate practicability and feasibility for real parts from manufacture a technology demonstrator part using the magnesium alloy ZM21

  8. Magnesium-phosphate-glass cements with ceramic-type properties

    Science.gov (United States)

    Sugama, T.; Kukacka, L.E.

    1982-09-23

    Rapid setting magnesium phosphate (Mg glass) cementitious materials consisting of magnesium phosphate cement paste, polyborax and water-saturated aggregate, exhibits rapid setting and high early strength characteristics. The magnesium glass cement is prepared from a cation-leachable powder and a bivalent metallic ion-accepting liquid such as an aqueous solution of diammonium phosphate and ammonium polyphosphate. The cation-leachable powder includes a mixture of two different magnesium oxide powders processed and sized differently which when mixed with the bivalent metallic ion-accepting liquid provides the magnesium glass cement consisting primarily of magnesium ortho phosphate tetrahydrate, with magnesium hydroxide and magnesium ammonium phosphate hexahydrate also present. The polyborax serves as a set-retarder. The resulting magnesium mono- and polyphosphate cements are particularly suitable for use as a cementing matrix in rapid repair systems for deteriorated concrete structures as well as construction materials and surface coatings for fireproof structures.

  9. Magnesium phosphate glass cements with ceramic-type properties

    Science.gov (United States)

    Sugama, Toshifumi; Kukacka, Lawrence E.

    1984-03-13

    Rapid setting magnesium phosphate (Mg glass) cementitious materials consisting of magnesium phosphate cement paste, polyborax and water-saturated aggregate exhibiting rapid setting and high early strength characteristics. The magnesium glass cement is prepared from a cation-leachable powder and a bivalent metallic ion-accepting liquid such as an aqueous solution of diammonium phosphate and ammonium polyphosphate. The cation-leachable powder includes a mixture of two different magnesium oxide powders processed and sized differently which when mixed with the bivalent metallic ion-accepting liquid provides the magnesium glass cement consisting primarily of magnesium ortho phosphate tetrahydrate, with magnesium hydroxide and magnesium ammonium phosphate hexahydrate also present. The polyborax serves as a set-retarder. The resulting magnesium mono- and polyphosphate cements are particularly suitable for use as a cementing matrix in rapid repair systems for deteriorated concrete structures as well as construction materials and surface coatings for fireproof structures.

  10. Magnesium deficiency and increased inflammation: current perspectives

    Directory of Open Access Journals (Sweden)

    Nielsen FH

    2018-01-01

    Full Text Available Forrest H Nielsen Research Nutritionist Consultant, Grand Forks, ND, USA Abstract: Animal studies have shown that magnesium deficiency induces an inflammatory response that results in leukocyte and macrophage activation, release of inflammatory cytokines and acute-phase proteins, and excessive production of free radicals. Animal and in vitro studies indicate that the primary mechanism through which magnesium deficiency has this effect is through increasing cellular Ca2+, which is the signal that results in the priming of cells to give the inflammatory response. Primary pro-inflammatory cytokines such as tumor necrosis factor-α and interleukin (IL-1; the messenger cytokine IL-6; cytokine responders E-selectin, intracellular adhesion molecule-1 and vascular cell adhesion molecule-1; and acute-phase reactants C-reactive protein and fibrinogen have been determined to associate magnesium deficiency with chronic low-grade inflammation (inflammatory stress. When magnesium dietary intake, supplementation, and/or serum concentration suggest/s the presence of magnesium deficiency, it often is associated with low-grade inflammation and/or with pathological conditions for which inflammatory stress is considered a risk factor. When magnesium intake, supplementation, and/or serum concentration suggest/s an adequate status, magnesium generally has not been found to significantly affect markers of chronic low-grade inflammation or chronic disease. The consistency of these findings can be modified by other nutritional and metabolic factors that affect inflammatory and oxidative stress. In spite of this, findings to date provide convincing evidence that magnesium deficiency is a significant contributor to chronic low-grade inflammation that is a risk factor for a variety of pathological conditions such as cardiovascular disease, hypertension, and diabetes. Because magnesium deficiency commonly occurs in countries where foods rich in magnesium are not consumed in

  11. Effect of Magnesium Hydride on the Corrosion Behavior of Pure Magnesium in 0.1 M NaCl Solution

    OpenAIRE

    Xu, Shanna; Dong, Junhua; Ke, Wei

    2010-01-01

    The effect of magnesium hydride on the corrosion behavior of pure magnesium in 0.1 M NaCl solution was investigated using the gas collection method, potentiostatic current decay test, and in situ Raman spectrum. The formation of magnesium hydride (MgH2, Mg2H4) was observed at the cathodic region. Applying anodic potential leads to decomposition of magnesium hydride. Magnesium hydride plays an important role on the negative difference effect (NDE) in both the cathodic and anodic regions.

  12. III. Penning ionization, associative ionization and chemi-ionization processes

    International Nuclear Information System (INIS)

    Cermak, V.

    1975-01-01

    Physical mechanisms of three important ionization processes in a cold plasma and the methods of their experimental study are discussed. An apparatus for the investigation of the Penning ionization using ionization processes of long lived metastable rare gas atoms is described. Methods of determining interaction energies and ionization rates from the measured energy spectra of the originating electrons are described and illustrated by several examples. Typical associative ionization processes are listed and the ionization rates are compared with those of the Penning ionization. Interactions with short-lived excited particles and the transfer of excitation without ionization are discussed. (J.U.)

  13. Corrosion and protection of magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Ghali, E. [Laval Univ., Quebec City, PQ (Canada). Dept. of Mining and Metallurgy

    2000-07-01

    The oxide film on magnesium offers considerable surface protection in rural and some industrial environments and the corrosion rate lies between that of aluminum and low carbon steels. Galvanic coupling of magnesium alloys, high impurity content such as Ni, Fe, Cu and surface contamination are detrimental for corrosion resistance of magnesium alloys. Alloying elements can form secondary particles which are noble to the Mg matrix, thereby facilitating corrosion, or enrich the corrosion product thereby possibly inhibiting the corrosion rate. Bimetallic corrosion resistance can be increased by fluxless melt protection, choice of compatible alloys, insulating materials, and new high-purity alloys. Magnesium is relatively insensible to oxygen concentration. Pitting, corrosion in the crevices, filiform corrosion are observed. Granular corrosion of magnesium alloys is possible due to the cathodic grain-boundary constituent. More homogeneous microstructures tend to improve corrosion resistance. Under fatigue loading conditions, microcrack initiation in Mg alloys is related to slip in preferentially oriented grains. Coating that exclude the corrosive environments can provide the primary defense against corrosion fatigue. Magnesium alloys that contain neither aluminum nor zinc are the most SCC resistant. Compressive surface residual stresses as that created by short peening increase SCC resistance. Cathodic polarization or cladding with a SCC resistant sheet alloy are good alternatives. Effective corrosion prevention for magnesium alloy components and assemblies should start at the design stage. Selective surface preparation, chemical treatment and coatings are recommended. Oil application, wax coating, anodizing, electroplating, and painting are possible alternatives. Recently, it is found that a magnesium hydride layer, created on the magnesium surface by cathodic charging in aqueous solution is a good base for painting. (orig.)

  14. Effect of Magnesium Hydride on the Corrosion Behavior of Pure Magnesium in 0.1 M NaCl Solution

    Directory of Open Access Journals (Sweden)

    Shanna Xu

    2010-01-01

    Full Text Available The effect of magnesium hydride on the corrosion behavior of pure magnesium in 0.1 M NaCl solution was investigated using the gas collection method, potentiostatic current decay test, and in situ Raman spectrum. The formation of magnesium hydride (MgH2, Mg2H4 was observed at the cathodic region. Applying anodic potential leads to decomposition of magnesium hydride. Magnesium hydride plays an important role on the negative difference effect (NDE in both the cathodic and anodic regions.

  15. Droplet Microfluidics Approach for Single-DNA Molecule Amplification and Condensation into DNA-Magnesium-Pyrophosphate Particles

    Directory of Open Access Journals (Sweden)

    Greta Zubaite

    2017-02-01

    Full Text Available Protein expression in vitro has broad applications in directed evolution, synthetic biology, proteomics and drug screening. However, most of the in vitro expression systems rely on relatively high DNA template concentrations to obtain sufficient amounts of proteins, making it harder to perform in vitro screens on gene libraries. Here, we report a technique for the generation of condensed DNA particles that can serve as efficient templates for in vitro gene expression. We apply droplet microfluidics to encapsulate single-DNA molecules in 3-picoliter (pL volume droplets and convert them into 1 μm-sized DNA particles by the multiple displacement amplification reaction driven by phi29 DNA polymerase. In the presence of magnesium ions and inorganic pyrophosphate, the amplified DNA condensed into the crystalline-like particles, making it possible to purify them from the reaction mix by simple centrifugation. Using purified DNA particles, we performed an in vitro transcription-translation reaction and successfully expressed complex enzyme β-galactosidase in droplets and in the 384-well format. The yield of protein obtained from DNA particles was significantly higher than from the corresponding amount of free DNA templates, thus opening new possibilities for high throughput screening applications.

  16. 21 CFR 582.5431 - Magnesium oxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Magnesium oxide. 582.5431 Section 582.5431 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5431 Magnesium oxide. (a) Product. Magnesium oxide. (b) Conditions of use. This substance...

  17. 21 CFR 582.1431 - Magnesium oxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Magnesium oxide. 582.1431 Section 582.1431 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1431 Magnesium oxide. (a) Product. Magnesium oxide. (b) Conditions of use. This substance is...

  18. 21 CFR 582.5443 - Magnesium sulfate.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Magnesium sulfate. 582.5443 Section 582.5443 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Supplements 1 § 582.5443 Magnesium sulfate. (a) Product. Magnesium sulfate. (b) Conditions of use. This...

  19. Separation of magnesium from magnesium chloride and zirconium and/or hafnium subchlorides in the production of zirconium and/or hafnium sponge metal

    International Nuclear Information System (INIS)

    Abodishish, H.A.M.; Adams, R.J.; Kearl, S.R.

    1992-01-01

    This patent describes the producing of a refractory metal wherein a sponge refractory metal is produced as an intermediate product by the use of magnesium with the incidental production of magnesium chloride, and wherein residual magnesium is separated from the magnesium chloride and from refractory metal to a vacuum distillation step which fractionally distills the magnesium, the magnesium chloride, and the metal sub-chlorides; the steps of: recovering fractionally distilled vapors of magnesium chloride and metal sub-chlorides from a sponge refractory metal; separately condensing the vapors as separately recovered; and recycling the separately recovered magnesium at a purity of at least about 96%

  20. Electronic structure and spectroscopy of nucleic acid bases: Ionization energies, ionization-induced structural changes, and photoelectron spectra

    Energy Technology Data Exchange (ETDEWEB)

    Bravaya, Ksenia B.; Kostko, Oleg; Dolgikh, Stanislav; Landau, Arie; Ahmed, Musahid; Krylov, Anna I.

    2010-08-02

    We report high-level ab initio calculations and single-photon ionization mass spectrometry study of ionization of adenine (A), thymine (T), cytosine (C) and guanine (G). For thymine and adenine, only the lowest-energy tautomers were considered, whereas for cytosine and guanine we characterized five lowest-energy tautomeric forms. The first adiabatic and several vertical ionization energies were computed using equation-of-motion coupled-cluster method for ionization potentials with single and double substitutions. Equilibrium structures of the cationic ground states were characterized by DFT with the {omega}B97X-D functional. The ionization-induced geometry changes of the bases are consistent with the shapes of the corresponding molecular orbitals. For the lowest-energy tautomers, the magnitude of the structural relaxation decreases in the following series G > C > A > T, the respective relaxation energies being 0.41, 0.32, 0.25 and 0.20 eV. The computed adiabatic ionization energies (8.13, 8.89, 8.51-8.67 and 7.75-7.87 eV for A,T,C and G, respectively) agree well with the onsets of the photoionization efficiency (PIE) curves (8.20 {+-} 0.05, 8.95 {+-} 0.05, 8.60 {+-} 0.05 and 7.75 {+-} 0.05 eV). Vibrational progressions for the S{sub 0}-D{sub 0} vibronic bands computed within double-harmonic approximation with Duschinsky rotations are compared with previously reported experimental photoelectron spectra.

  1. Assessment of serum magnesium levels and its outcome in neonates of eclamptic mothers treated with low-dose magnesium sulfate regimen

    Science.gov (United States)

    Das, Monalisa; Chaudhuri, Patralekha Ray; Mondal, Badal C.; Mitra, Sukumar; Bandyopadhyay, Debasmita; Pramanik, Sushobhan

    2015-01-01

    Objectives: Magnesium historically has been used for treatment and/or prevention of eclampsia. Considering the low body mass index of Indian women, a low-dose magnesium sulfate regime has been introduced by some authors. Increased blood levels of magnesium in neonates is associated with increased still birth, early neonatal death, birth asphyxia, bradycardia, hypotonia, gastrointestinal hypomotility. The objective of this study was to assess safety of low-dose magnesium sulfate regimen in neonates of eclamptic mothers treated with this regimen. Materials and Methods: This was a cross-sectional observational study of 100 eclampsia patients and their neonates. Loading dose and maintenance doses of magnesium sulfate were administered to patients by combination of intravenous and intramuscular routes. Maternal serum and cord blood magnesium levels were estimated. Neonatal outcome was assessed. Results: Bradycardia was observed in 18 (19.15%) of the neonates, 16 (17.02%) of the neonates were diagnosed with hypotonia. Pearson Correlation Coefficient showed Apgar scores decreased with increase in cord blood magnesium levels. Unpaired t-test showed lower Apgar scores with increasing dose of magnesium sulfate. The Chi-square/Fisher's exact test showed significant increase in hypotonia, birth asphyxia, intubation in delivery room, Neonatal Intensive Care Unit (NICU) care requirement, with increasing dose of magnesium sulfate. (P ≤ 0.05). Conclusion: Several neonatal complications are significantly related to increasing serum magnesium levels. Overall, the low-dose magnesium sulfate regimen was safe in the management of eclamptic mothers, without toxicity to their neonates. PMID:26600638

  2. Improved cytotoxicity testing of magnesium materials

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Janine [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Department for Structural Research on Macromolecules, Max-Planck Str. 1, D - 21502 Geesthacht (Germany); Proefrock, Daniel [Helmholtz-Zentrum Geesthacht, Institute for Coastal Research, Department for Marine Bioanalytical Chemistry, Max-Planck Str. 1, D - 21502 Geesthacht (Germany); Hort, Norbert [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Department for Magnesium Processing, Max-Planck Str. 1, D - 21502 Geesthacht (Germany); Willumeit, Regine; Feyerabend, Frank [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Department for Structural Research on Macromolecules, Max-Planck Str. 1, D - 21502 Geesthacht (Germany)

    2011-06-25

    Metallic magnesium (Mg) and its alloys are highly suitable for medical applications as biocompatible and biodegradable implant materials. Magnesium has mechanical properties similar to bone, stimulates bone regeneration, is an essential non-toxic element for the human body and degrades completely within the body environment. In consequence, magnesium is a promising candidate as implant material for orthopaedic applications. Protocols using the guideline of current ISO standards should be carefully evaluated when applying them for the characterization of the cytotoxic potential of degradable magnesium materials. For as-cast material we recommend using 10 times more extraction medium than recommended by the ISO standards to obtain reasonable results for reliable cytotoxicity rankings of degradable materials in vitro. In addition primary isolated human osteoblasts or mesenchymal stem cells should be used to test magnesium materials.

  3. Improved cytotoxicity testing of magnesium materials

    International Nuclear Information System (INIS)

    Fischer, Janine; Proefrock, Daniel; Hort, Norbert; Willumeit, Regine; Feyerabend, Frank

    2011-01-01

    Metallic magnesium (Mg) and its alloys are highly suitable for medical applications as biocompatible and biodegradable implant materials. Magnesium has mechanical properties similar to bone, stimulates bone regeneration, is an essential non-toxic element for the human body and degrades completely within the body environment. In consequence, magnesium is a promising candidate as implant material for orthopaedic applications. Protocols using the guideline of current ISO standards should be carefully evaluated when applying them for the characterization of the cytotoxic potential of degradable magnesium materials. For as-cast material we recommend using 10 times more extraction medium than recommended by the ISO standards to obtain reasonable results for reliable cytotoxicity rankings of degradable materials in vitro. In addition primary isolated human osteoblasts or mesenchymal stem cells should be used to test magnesium materials.

  4. Double ionization of atomic helium under heavy ion impact

    International Nuclear Information System (INIS)

    Presnyakov, L.P.; Uskov, D.B.

    1995-01-01

    Cross sections for double ionization of helium by multiply-charged ion impact and the corresponding ratios of double-to-single ionization are presented as a sum of the contributions given by the one-step (shake-off) and two-step (TS) processes. An analytic form is found for the continuum wavefunction which is valid in both limiting cases of low and high velocities of the relative motion. Using this wavefunction, the TS cross sections are calculated within the independent-event model. The results for the ratios of double-to-single ionization show satisfactory agreement with the experimental data available. (author)

  5. Studies of synthetic single crystal diamonds as reliable dosimeters for electromagnetic ionizing radiation fields

    International Nuclear Information System (INIS)

    Pillon, Mario; Angelone, Maurizio; Almaviva, Salvatore; Marinelli, Marco; Milani, Enrico; Prestopino, Giuseppe; Tucciarone, Aldo; Verona, Claudio; Verona-Rinati, Gianluca; Baccaro, Stefania

    2008-01-01

    Full text: Spatial high resolution dosimetry is very important in all areas of radiation therapy and, in particular, whenever narrow photon beams are required for Stereotactic Radiotherapy (SRT) and small field segments are used for Intensity Modulated Radiotherapy (IMRT). The available detectors are often too large with respect to the beam size considered, which is characterized by high dose gradients and lack of charged particle equilibrium. An ideal solution is represented by single crystal diamond detectors, which are small solid state devices, radiation hard, tissue equivalent and capable of real time response. In the present work, synthetic CVD single crystal diamond dosimeters (SCD), fabricated at Rome 'Tor Vergata' University Laboratories, have been characterized. The devices consist of a p-type/intrinsic/metal layered structure. They have been analyzed in terms of reproducibility, linearity, depth dose distributions, energy, dose rate and field size dependence by using 6 and 10 MV Bremsstrahlung x-ray beams, produced by a CLINAC DHX Varian accelerator and the gamma irradiation facility CALLIOPE. The gamma Calliope plant is a pool-type irradiation facility equipped with the 60 Co γ-source in a high-volume (7 x 6 x 3.9m 3 ). Maximum dose rate is 9400 Gy/h. The measurements have been compared with a calibrated ionization chamber and a Fricke dosimeter. The SCD's response is shown to be linearly correlated with the ionization chamber output over the whole dose range explored. Reproducibility, energy and dose rate dependency lower than 1% were observed. A depth dose distribution and irradiation field dependence in agreement with those obtained by reference dosimeters within 2% of accuracy were demonstrated as well. The results of this study are very encouraging about the suitability of SCD for clinical dosimetry with photon beams. (author)

  6. Theoretical studies of highly ionized species. Progress report, March 1, 1977--February 28, 1978

    International Nuclear Information System (INIS)

    Dalgarno, A.; Victor, G.A.

    1977-11-01

    The relativistic random phase approximation has been used to study the helium, beryllium, magnesium and zinc isoelectronic sequences. Model potential methods have been employed to study multi-photon ionization of sodium from the ground and excited states. Forbidden decays in the Be and Mg isoelectronic sequences have been investigated. The 1s2p 2 2 P and 1s2p 2 2 D states of lithium-like ions have been studied. Calculations of radiative charge transfer have been carried out

  7. Magnesium balances and 28Mg studies in man

    International Nuclear Information System (INIS)

    Spencer, H.; Schwartz, R.; Osis, D.

    1988-01-01

    The intestinal absorption of magnesium was determined under strictly controlled dietary conditions in patients with normal renal function and also in patients with chronic renal failure. The average net absorption of magnesium of patients with normal renal function, expressed as percent of the magnesium intake, was 48.5%, while that of patients with chronic renal failure was significantly lower, 17%. Increasing the calcium intake from a low calcium intake of 200 mg/day to different higher intake levels up to 2000 mg/day did not change the magnesium balance nor the net absorption of magnesium of both types of patients. The lack of effect of the higher calcium intake on the absorption of magnesium was confirmed in 28 Mg studies in which an oral dose of 28 Mg, as the chloride, was given. The excretion of the absorbed magnesium into the intestine, the endogenous fecal magnesium, was low. Also, increasing the phosphorus intake up to 2000 mg/day in subjects with normal renal function did not affect the magnesium balance, regardless of the calcium intake

  8. Aluminum Hydroxide and Magnesium Hydroxide

    Science.gov (United States)

    Aluminum Hydroxide, Magnesium Hydroxide are antacids used together to relieve heartburn, acid indigestion, and upset stomach. They ... They combine with stomach acid and neutralize it. Aluminum Hydroxide, Magnesium Hydroxide are available without a prescription. ...

  9. Serum magnesium levels in patients with pre-eclampsia and eclampsia with different regimens of magnesium sulphate

    Directory of Open Access Journals (Sweden)

    Arpita Singh

    2013-01-01

    Full Text Available Background Pre-eclampsia and the subsequent eclampsia account for a common cause of maternal mortality worldwide and efforts aimed at reducing its menace are vital. Objective To estimate the serum magnesium levels in pre-eclampsia and eclampsia and to study the effect of using different regimens of magnesium sulphate. Methods 70 cases of pre-eclampsia and eclampsia and 35 normal pregnant women as controls were studied. Serum magnesium levels were estimated using Atomic Absorption Spectrophotometer (Model AAS-4139 at baseline and at frequent intervals during gestation and the overall parameters were meticulously observed. Results Majority(60%ofstudiedcaseswasnulliparawithgestationageof36-40 weeks. Statistically significant reduction of mean diastolic blood pressure and protein-urea was observed after using both intramuscular and intravenous regimens of magnesium sulphate. Mean initial serum magnesium level (mg/dl±SD was 1.81±0.58 in group A,1.55±0.41 in group B and 1.49±0.41 in group C. Mean serum magnesium levels during first 4 hours after therapy were statistically significant between intramuscular and intravenous regimen groups while same were statistically insignificant at 8,12,16,24 and 32 hours. Besides, few minor side effects including headache, vomiting, reduced tendon reflexes and thrombocytopenia, no severe side effects and no maternal mortality were seen. Conclusion Hypomagnesemia occurs during states of preeclampsia and eclampsia, and, administration of magnesium sulphate is effective and safe in preventing maternal mortality.

  10. Serum magnesium levels in patients with pre-eclampsia and eclampsia with different regimens of magnesium sulphate

    Directory of Open Access Journals (Sweden)

    Arpita Singh

    2013-03-01

    Full Text Available Background Pre-eclampsia and the subsequent eclampsia account for a common cause of maternal mortality worldwide and efforts aimed at reducing its menace are vital. Objective To estimate the serum magnesium levels in pre-eclampsia and eclampsia and to study the effect of using different regimens of magnesium sulphate. Methods 70 cases of pre-eclampsia and eclampsia and 35 normal pregnant women as controls were studied. Serum magnesium levels were estimated using Atomic Absorption Spectrophotometer (Model AAS-4139 at baseline and at frequent intervals during gestation and the overall parameters were meticulously observed. Results Majority (60% of studied cases was nullipara with gestation age of 36-40 weeks. Statistically significant reduction of mean diastolic blood pressure and protein-urea was observed after using both intramuscular and intravenous regimens of magnesium sulphate. Mean initial serum magnesium level (mg/dl±SD was 1.81±0.58 in group A,1.55±0.41 in group B and 1.49±0.41 in group C. Mean serum magnesium levels during first 4 hours after therapy were statistically significant between intramuscular and intravenous regimen groups while same were statistically insignificant at 8,12,16,24 and 32 hours. Besides, few minor side effects including headache, vomiting, reduced tendon reflexes and thrombocytopenia, no severe side effects and no maternal mortality were seen. Conclusion Hypomagnesemia occurs during states of preeclampsia and eclampsia, and, administration of magnesium sulphate is effective and safe in preventing maternal mortality.

  11. Laser ablation of ceramic Al2O3 at 193 nm and 248 nm: The importance of single-photon ionization processes

    Science.gov (United States)

    Peláez, R. J.; Afonso, C. N.; Bator, M.; Lippert, T.

    2013-06-01

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al2O3 in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to ≈2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al+ ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  12. Analysis of laser-generated plasma ionizing radiation by synthetic single crystal diamond detectors

    Czech Academy of Sciences Publication Activity Database

    Marinelli, M.; Milani, E.; Prestopino, G.; Verona, C.; Verona-Rinati, G.; Cutroneo, M.; Torrisi, L.; Margarone, Daniele; Velyhan, Andriy; Krása, Josef; Krouský, Eduard

    2013-01-01

    Roč. 272, May (2013), s. 104-108 ISSN 0169-4332 R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE2.3.20.0279; GA MŠk EE.2.3.20.0087; GA MŠk(CZ) 7E09092; GA MŠk(CZ) LC528 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; OPVK 3 Laser Zdroj(XE) CZ.1.07/2.3.00/20.0279; OP VK 2 LaserGen(XE) CZ.1.07/2.3.00/20.0087; 7FP LASERLAB-EUROPE(XE) 228334 Program:EE; FP7 Institutional support: RVO:68378271 Keywords : single crystal diamond * diamond detector * laser-generated plasma * ionizing radiation * time-of-fight spectrometer Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.538, year: 2013

  13. Computational micromechanics of bioabsorbable magnesium stents.

    Science.gov (United States)

    Grogan, J A; Leen, S B; McHugh, P E

    2014-06-01

    Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316L and cobalt chromium L605. In particular, magnesium exhibits asymmetric plastic behaviour (i.e. different yield behaviours in tension and compression) and has lower ductility than these conventional alloys. In the on-going development of absorbable metal stents it is important to assess how the unique behaviour of magnesium affects device performance. The mechanical behaviour of magnesium stent struts is investigated in this study using computational micromechanics, based on finite element analysis and crystal plasticity theory. The plastic deformation in tension and bending of textured and non-textured magnesium stent struts with different numbers of grains through the strut dimension is investigated. It is predicted that, unlike 316L and L605, the failure risk and load bearing capacity of magnesium stent struts during expansion is not strongly affected by the number of grains across the strut dimensions; however texturing, which may be introduced and controlled in the manufacturing process, is predicted to have a significant influence on these measures of strut performance. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Magnesium fluoride recovery method

    International Nuclear Information System (INIS)

    Gay, R.L.; McKenzie, D.E.

    1989-01-01

    A method of obtaining magnesium fluoride substantially free from radioactive uranium from a slag formed in the production of metallic uranium by the reduction of depleted uranium tetrafluoride with metallic magnesium in a retort wherein the slag contains the free metals magnesium and uranium and also oxides and fluorides of the metals. The slag having a radioactivity level of at least about 7,000 rhoCi/gm. The method comprises the steps of: grinding the slag to a median particle size of about 200 microns; contacting the ground slag in a reaction zone with an acid having a strength of from about 0.5 to 1.5 N for a time of from about 4 to about 20 hours in the presence of a catalytic amount of iron; removing the liquid product; treating the particulate solid product; repeating the last two steps at least one more time to produce a solid residue consisting essentially of magnesium fluoride substantially free of uranium and having a residual radioactivity level of less than about 1000 rhoCi/gm

  15. Radioactive {sup 210}Po in magnesium supplements

    Energy Technology Data Exchange (ETDEWEB)

    Struminska-Parulska, Dagmara Ida [Gdansk Univ. (Poland). Environmental Chemistry and Radiochemistry Chair

    2016-08-01

    The aim of this pioneer study was to determine polonium {sup 210}Po in the most popular magnesium supplements in Poland and estimate the possible related dose assessment to the consumers. The analyzed magnesium pharmaceutics contained organic or inorganic magnesium compounds; some from natural sources. The objectives of this research were to investigate the naturally occurring {sup 210}Po activity concentrations in magnesium supplements, find the correlations between {sup 210}Po concentration in medicament and magnesium chemical form, and calculate the effective radiation dose connected to analyzed magnesium supplement consumption. The highest {sup 210}Po activity concentrations were determined in mineral tablets made from sedimentary rocks, namely dolomite - 3.84 ± 0.15 mBq g{sup -1} (sample Mg17). The highest annual radiation dose from {sup 210}Po taken with 1 tablet of magnesium supplement per day or with 400 mg of pure Mg daily would come from sample Mg17 (dolomite) - 1.35 ± 0.5 and 8.44 ± 0.33 μSv year{sup -1} respectively.

  16. Distinction between magnesium diboride and tetraboride by kelvin probe force microscopy

    International Nuclear Information System (INIS)

    Kim, Du-Na; Caron, Arnaud; Park, Hai Woong

    2016-01-01

    We analyze mixtures of magnesium diboride and tetraboride synthesized with magnesium powders of different shapes. To distinguish between magnesium diboride and tetraboride we use the contrast of kelvin probe force microscopy. The microstructural morphology strongly depends on the shape of the magnesium powders used in the reaction between magnesium and magnesium tetraboride to form magnesium diboride. With spherical magnesium powder an equiaxed microstructure of magnesium diboride is formed with residual magnesium tetraboride at the grain boundaries. With plate-like magnesium powders elongated magnesium diboride grains are formed. In this case, residual magnesium tetraboride is found to agglomerate.

  17. Mechanistic Study of Magnesium Carbonate Semibatch Reactive Crystallization with Magnesium Hydroxide and CO2

    DEFF Research Database (Denmark)

    Han, B.; Qu, H. Y.; Niemi, H.

    2014-01-01

    This work investigates semibatch precipitation of magnesium carbonate at ambient temperature and pressure using Mg(OH)(2) and CO2 as starting materials. A thermal analysis method was developed that reflects the dissolution rate of Mg(OH)(2) and the formation of magnesium carbonate. The method...... the liquid and solid phases. A stirring rate of 650 rpm was found to be the optimum speed as the flow rate of CO2 was 1 L/min. Precipitation rate increased with gas flow rate, which indicates that mass transfer of CO2 plays a critical role in this precipitation case. Magnesium carbonate trihydrate...

  18. Solvation of magnesium dication: molecular dynamics simulation and vibrational spectroscopic study of magnesium chloride in aqueous solutions.

    Science.gov (United States)

    Callahan, Karen M; Casillas-Ituarte, Nadia N; Roeselová, Martina; Allen, Heather C; Tobias, Douglas J

    2010-04-22

    Magnesium dication plays many significant roles in biochemistry. While it is available to the environment from both ocean waters and mineral salts on land, its roles in environmental and atmospheric chemistry are still relatively unknown. Several pieces of experimental evidence suggest that contact ion pairing may not exist at ambient conditions in solutions of magnesium chloride up to saturation concentrations. This is not typical of most ions. There has been disagreement in the molecular dynamics literature concerning the existence of ion pairing in magnesium chloride solutions. Using a force field developed during this study, we show that contact ion pairing is not energetically favorable. Additionally, we present a concentration-dependent Raman spectroscopic study of the Mg-O(water) hexaaquo stretch that clearly supports the absence of ion pairing in MgCl(2) solutions, although a transition occurring in the spectrum between 0.06x and 0.09x suggests a change in solution structure. Finally, we compare experimental and calculated observables to validate our force field as well as two other commonly used magnesium force fields, and in the process show that ion pairing of magnesium clearly is not observed at higher concentrations in aqueous solutions of magnesium chloride, independent of the choice of magnesium force field, although some force fields give better agreement to experimental results than others.

  19. Intradermal administration of magnesium sulphate and magnesium chloride produces hypesthesia to mechanical but hyperalgesia to heat stimuli in humans

    Directory of Open Access Journals (Sweden)

    Ikemoto Tatsunori

    2009-08-01

    Full Text Available Abstract Background Although magnesium ions (Mg2+ are known to display many similar features to other 2+ charged cations, they seem to have quite an important and unique role in biological settings, such as NMDA blocking effect. However, the role of Mg2+ in the neural transmission system has not been studied as sufficiently as calcium ions (Ca2+. To clarify the sensory effects of Mg2+ in peripheral nervous systems, sensory changes after intradermal injection of Mg2+ were studied in humans. Methods Magnesium sulphate, magnesium chloride and saline were injected into the skin of the anterior region of forearms in healthy volunteers and injection-induced irritating pain ("irritating pain", for short, tactile sensation, tactile pressure thresholds, pinch-pain changes and intolerable heat pain thresholds of the lesion were monitored. Results Flare formation was observed immediately after magnesium sulphate or magnesium chloride injection. We found that intradermal injections of magnesium sulphate and magnesium chloride transiently caused irritating pain, hypesthesia to noxious and innocuous mechanical stimulations, whereas secondary hyperalgesia due to mechanical stimuli was not observed. In contrast to mechanical stimuli, intolerable heat pain-evoking temperature was significantly decreased at the injection site. In addition to these results, spontaneous pain was immediately attenuated by local cooling. Conclusion Membrane-stabilizing effect and peripheral NMDA-blocking effect possibly produced magnesium-induced mechanical hypesthesia, and extracellular cation-induced sensitization of TRPV1 channels was thought to be the primary mechanism of magnesium-induced heat hyperalgesia.

  20. Effect of magnesium hydride on the corrosion behavior of an AZ91 magnesium alloy in sodium chloride solution

    International Nuclear Information System (INIS)

    Chen Jian; Dong Junhua; Wang Jianqiu; Han Enhou; Ke Wei

    2008-01-01

    The effect of magnesium hydride on the corrosion behavior of an as-cast AZ91 alloy in 3.5 wt.% NaCl solution was investigated using gas collection method and potentiostatic test. The Pourbaix diagram of Mg-H 2 O system was built using thermodynamic calculation. It was possible that magnesium hydride could form in the whole pH range in theory. The experimental results showed that at cathodic region, magnesium hydride formed on surface, which was the controlling process for the corrosion behavior of AZ91 alloy; at anodic region and free corrosion potential, magnesium hydride model and partially protective film model, monovalent magnesium ion model and particle undermining model were responsible for the corrosion process of AZ91 alloy

  1. Higher dietary magnesium intake and higher magnesium status are associated with lower prevalence of coronary heart disease in patients with type 2 diabetes

    NARCIS (Netherlands)

    Gant, C.M.; Soedamah-Muthu, S.S.; Binnenmars, S.H.; Bakker, S.J.L.; Navis, G.; Laverman, G.D.

    2018-01-01

    In type 2 diabetes mellitus (T2D), the handling of magnesium is disturbed. Magnesium deficiency may be associated with a higher risk of coronary heart disease (CHD). We investigated the associations between (1) dietary magnesium intake; (2) 24 h urinary magnesium excretion; and (3) plasma magnesium

  2. Serum magnesium concentration in drug-addicted patients.

    Science.gov (United States)

    Karakiewicz, Beata; Kozielec, Tadeusz; Brodowski, Jacek; Chlubek, Dariusz; Noceń, Iwona; Starczewski, Andrzej; Brodowska, Agnieszka; Laszczyńska, Maria

    2007-03-01

    Drug addiction is a complex problem which leads to many somatic, psychic and social diseases. It is accompanied by the disturbed metabolism of various macro and micronutrients. The aim of this study was to assess serum magnesium concentration in drug-addicted patients and analyze whether Human Immunodeficiency Virus (HIV) infection and methadone treatment affect the level of serum magnesium in these patients. The examination was conducted in a group of 83 people - patients of Szczecin-Zdroje Psychiatric Hospital (Poland). They were 21 to 49 years old, and the mean age was 32 +/- 7 years. The control group consisted of 81 healthy individuals. Flame atomic-absorption spectrometry method was used to determine the magnesium concentration. The total serum magnesium concentration was calculated for the whole patient group, subgroups of women and men, a subgroup of people infected with HIV, and a subgroup receiving methadone substitution treatment. How magnesium behaves depending on age and addiction period, was checked. The mean concentration of magnesium in blood serum of the patients examined was 0.57 mmol/L, which was significantly lower than in the control group. In the subgroup of men it was 0.57 mmol/L, and in the subgroup of women - 0.55 mmol/L; the differences were not statistically significant. In the patient group nobody had the appropriate magnesium concentration in blood serum. No significant correlation was found between the magnesium concentration, age of the patients and addiction period. In the subgroup of seropositive people the mean concentration of magnesium was 0.55 mmol/L, and in the subgroup of non-infected patients - 0.58 mmol/L; the difference was not statistically significant. The mean concentration of magnesium in the subgroup treated with methadone was 0.59 mmol/L, and in the subgroup not involved in this type of therapy - 0.55 mmol/L; it was not a statistically significant difference.

  3. EFFECT OF PREEMPTIVE MAGNESIUM SULPHATE ON PAIN RELIEF AFTER LAPAROSCOPIC CHOLECYSTECTOMY

    Directory of Open Access Journals (Sweden)

    Ravi Vasupalli

    2016-09-01

    Full Text Available BACKGROUND The concept of preemptive analgesia was introduced by C. J. Woolf et al demonstrating that a post-injury hypersensitivity results via a central mechanism. The effect of magnesium on perioperative analgesic requirements was first evaluated by Koinig and his colleagues in patients with identical levels of surgical stimulation. Magnesium Sulphate is an antagonist of Nmethyl-D-aspartate (NMDA receptors and its associated channels and regulation of calcium influx into the cell. Magnesium causes modulation of acute pain reducing postsurgical pain intensity and dosage of analgesics. Seyhan et al have reported that magnesium sulphate boluses were effective for postoperative pain relief after gynaecological surgery. Fucs-Budder et al, Kussman B et al used continuous infusion (15 mg/kg/hr. in addition to initial bolus (50 mg/kg of magnesium sulphate in their studies, which caused bradycardia and delayed extubation time, which can be attributed to the infusion of Iva Bacak Kochman et al studied effect of low dose MgSO4 (7.5 mg/kg as analgesic agent after induction in patients undergoing laparoscopic cholecystectomy. This bolus dose of MgSO4 given for control of sympathetic response during intubation also reduced early postoperative pain. Study conducted by O Mentes et al on postoperative analgesic efficacy of single dose MgSO4 (50 mg/kg after laparoscopic cholecystectomy measured significantly less VAS scores. On this background, our study was done to evaluate the postoperative analgesic efficacy of single dose of magnesium sulphate (50 mg/kg as preemptive analgesic and measured after laparoscopic cholecystectomy. In addition to VAS scores, total tramadol consumption and time for first rescue analgesia, postoperative haemodynamic parameters and side effects if any were evaluated. METHODS After obtaining Institutional Ethical committee clearance and written informed consent from the patients, a randomised prospective study was conducted at King

  4. The Role of Magnesium in Neurological Disorders

    Directory of Open Access Journals (Sweden)

    Anna E. Kirkland

    2018-06-01

    Full Text Available Magnesium is well known for its diverse actions within the human body. From a neurological standpoint, magnesium plays an essential role in nerve transmission and neuromuscular conduction. It also functions in a protective role against excessive excitation that can lead to neuronal cell death (excitotoxicity, and has been implicated in multiple neurological disorders. Due to these important functions within the nervous system, magnesium is a mineral of intense interest for the potential prevention and treatment of neurological disorders. Current literature is reviewed for migraine, chronic pain, epilepsy, Alzheimer’s, Parkinson’s, and stroke, as well as the commonly comorbid conditions of anxiety and depression. Previous reviews and meta-analyses are used to set the scene for magnesium research across neurological conditions, while current research is reviewed in greater detail to update the literature and demonstrate the progress (or lack thereof in the field. There is strong data to suggest a role for magnesium in migraine and depression, and emerging data to suggest a protective effect of magnesium for chronic pain, anxiety, and stroke. More research is needed on magnesium as an adjunct treatment in epilepsy, and to further clarify its role in Alzheimer’s and Parkinson’s. Overall, the mechanistic attributes of magnesium in neurological diseases connote the macromineral as a potential target for neurological disease prevention and treatment.

  5. Strong suppression of the positronium channel in double ionization of noble gases by positron impact

    DEFF Research Database (Denmark)

    Bluhme, H.; Knudsen, H.; Merrison, J.P.

    1998-01-01

    Positron-induced double ionization of helium and neon has been studied at energies from threshold to 900 eV. A remarkable difference between the near-threshold behavior of the single and double ionization cross sections is found: Single ionization is dominated by positronium (Ps) formation, while...

  6. Nanostructured magnesium has fewer detrimental effects on osteoblast function

    Directory of Open Access Journals (Sweden)

    Weng L

    2013-05-01

    Full Text Available Lucy Weng, Thomas J Webster School of Engineering and Department of Orthopedics, Brown University, Providence, RI, USA Abstract: Efforts have been made recently to implement nanoscale surface features on magnesium, a biodegradable metal, to increase bone formation. Compared with normal magnesium, nanostructured magnesium has unique characteristics, including increased grain boundary properties, surface to volume ratio, surface roughness, and surface energy, which may influence the initial adsorption of proteins known to promote the function of osteoblasts (bone-forming cells. Previous studies have shown that one way to increase nanosurface roughness on magnesium is to soak the metal in NaOH. However, it has not been determined if degradation of magnesium is altered by creating nanoscale features on its surface to influence osteoblast density. The aim of the present in vitro study was to determine the influence of degradation of nanostructured magnesium, created by soaking in NaOH, on osteoblast density. Our results showed a less detrimental effect of magnesium degradation on osteoblast density when magnesium was treated with NaOH to create nanoscale surface features. The detrimental degradation products of magnesium are of significant concern when considering use of magnesium as an orthopedic implant material, and this study identified a surface treatment, ie, soaking in NaOH to create nanoscale features for magnesium that can improve its use in numerous orthopedic applications. Keywords: nanostructured magnesium, degradation, detrimental effects, osteoblasts

  7. Corrosion Screening of EV31A Magnesium and Other Magnesium Alloys using Laboratory-Based Accelerated Corrosion and Electro-Chemical Methods

    Science.gov (United States)

    2014-07-01

    Spray. Journal of Failure Analysis and Prevention 2008, 8 (2), 164–175. 34. Aluminium Alloy 5083, Plate and Sheet; SAE-AMS-QQ-A-250/6S; SAE...Corrosion Screening of EV31A Magnesium and Other Magnesium Alloys Using Laboratory-Based Accelerated Corrosion and Electro-chemical Methods...Magnesium and Other Magnesium Alloys Using Laboratory-Based Accelerated Corrosion and Electro-chemical Methods Brian E. Placzankis, Joseph P

  8. Hydrostatic extrusion of magnesium alloys

    NARCIS (Netherlands)

    Sillekens, W.H.; Bohlen, J.

    2012-01-01

    This chapter deals with the capabilities and limitations of the hydrostatic extrusion process for the manufacturing of magnesium alloy sections. Firstly, the process basics for the hydrostatic extrusion of materials in general and of magnesium in particular are introduced. Next, some recent research

  9. Magnesium bicarbonate as an in situ uranium lixiviant

    International Nuclear Information System (INIS)

    Sibert, J.W.

    1984-01-01

    In the subsurface solution mining of mineral values, especially uranium, in situ, magnesium bicarbonate leaching solution is used instead of sodium, potassium and ammonium carbonate and bicarbonates. The magnesium bicarbonate solution is formed by combining carbon dioxide with magnesium oxide and water. The magnesium bicarbonate lixivant has four major advantages over prior art sodium, potassium and ammonium bicarbonates

  10. Magnesium supplement in pregnancy-induced hypertension. A clinicopathological study

    DEFF Research Database (Denmark)

    Rudnicki, M; Junge, Jette; Frølich, A

    1990-01-01

    as a double-blind randomized controlled study in which 11 women were allocated to magnesium and 7 to placebo treatment. The treatment comprised a 48-hour intravenous magnesium/placebo infusion followed by daily oral magnesium/placebo intake until one day after delivery. Magnesium supplement increased birth....... There was no significant difference when the magnesium group, the placebo group and the control group were compared separately. The present study suggests that magnesium supplement has a beneficial effect on fetal growth in pregnancy-induced hypertension. With regard to the light and electron microscopic changes we were...... unable to demonstrate any significant difference between the magnesium, placebo and control groups....

  11. Nanostructured magnesium has fewer detrimental effects on osteoblast function

    Science.gov (United States)

    Weng, Lucy; Webster, Thomas J

    2013-01-01

    Efforts have been made recently to implement nanoscale surface features on magnesium, a biodegradable metal, to increase bone formation. Compared with normal magnesium, nanostructured magnesium has unique characteristics, including increased grain boundary properties, surface to volume ratio, surface roughness, and surface energy, which may influence the initial adsorption of proteins known to promote the function of osteoblasts (bone-forming cells). Previous studies have shown that one way to increase nanosurface roughness on magnesium is to soak the metal in NaOH. However, it has not been determined if degradation of magnesium is altered by creating nanoscale features on its surface to influence osteoblast density. The aim of the present in vitro study was to determine the influence of degradation of nanostructured magnesium, created by soaking in NaOH, on osteoblast density. Our results showed a less detrimental effect of magnesium degradation on osteoblast density when magnesium was treated with NaOH to create nanoscale surface features. The detrimental degradation products of magnesium are of significant concern when considering use of magnesium as an orthopedic implant material, and this study identified a surface treatment, ie, soaking in NaOH to create nanoscale features for magnesium that can improve its use in numerous orthopedic applications. PMID:23674891

  12. Nanostructured magnesium has fewer detrimental effects on osteoblast function.

    Science.gov (United States)

    Weng, Lucy; Webster, Thomas J

    2013-01-01

    Efforts have been made recently to implement nanoscale surface features on magnesium, a biodegradable metal, to increase bone formation. Compared with normal magnesium, nanostructured magnesium has unique characteristics, including increased grain boundary properties, surface to volume ratio, surface roughness, and surface energy, which may influence the initial adsorption of proteins known to promote the function of osteoblasts (bone-forming cells). Previous studies have shown that one way to increase nanosurface roughness on magnesium is to soak the metal in NaOH. However, it has not been determined if degradation of magnesium is altered by creating nanoscale features on its surface to influence osteoblast density. The aim of the present in vitro study was to determine the influence of degradation of nanostructured magnesium, created by soaking in NaOH, on osteoblast density. Our results showed a less detrimental effect of magnesium degradation on osteoblast density when magnesium was treated with NaOH to create nanoscale surface features. The detrimental degradation products of magnesium are of significant concern when considering use of magnesium as an orthopedic implant material, and this study identified a surface treatment, ie, soaking in NaOH to create nanoscale features for magnesium that can improve its use in numerous orthopedic applications.

  13. The role of magnesium in the electrochemical behaviour of 5XXX aluminium-magnesium alloys

    NARCIS (Netherlands)

    Flores Ramirez, J.R.

    2006-01-01

    An investigation concerning the effects of magnesium on the intergranular corrosion susceptibility of AA5XXX aluminium alloys was carried out. In the present work, magnesium is found to be highly mobile in the bulk metal as well as in the aluminium oxide. This mobility is also found to be dependent

  14. An approach to modelling radiation damage by fast ionizing particles

    International Nuclear Information System (INIS)

    Thomas, G.E.

    1987-01-01

    The paper presents a statistical approach to modelling radiation damage in small biological structures such as enzymes, viruses, and some cells. Irreparable damage is assumed to be caused by the occurrence of ionizations within sensitive regions. For structures containing double-stranded DNA, one or more ionizations occurring within each strand of the DNA will cause inactivation; for simpler structures without double-stranded DNA a single ionization within the structure will be sufficient for inactivation. Damaging ionizations occur along tracks of primary irradiating particles or along tracks of secondary particles released at primary ionizations. An inactivation probability is derived for each damage mechanism, expressed in integral form in terms of the radius of the biological structure (assumed spherical), rate of ionization along primary tracks, and maximum energy for secondary particles. The performance of each model is assessed by comparing results from the model with those derived from data from various experimental studies extracted from the literature. For structures where a single ionization is sufficient for inactivation, the model gives qualitatively promising results; for larger more complex structures containing double-stranded DNA, the model requires further refinements. (author)

  15. Trace detection of organic compounds in complex sample matrixes by single photon ionization ion trap mass spectrometry: real-time detection of security-relevant compounds and online analysis of the coffee-roasting process.

    Science.gov (United States)

    Schramm, Elisabeth; Kürten, Andreas; Hölzer, Jasper; Mitschke, Stefan; Mühlberger, Fabian; Sklorz, Martin; Wieser, Jochen; Ulrich, Andreas; Pütz, Michael; Schulte-Ladbeck, Rasmus; Schultze, Rainer; Curtius, Joachim; Borrmann, Stephan; Zimmermann, Ralf

    2009-06-01

    An in-house-built ion trap mass spectrometer combined with a soft ionization source has been set up and tested. As ionization source, an electron beam pumped vacuum UV (VUV) excimer lamp (EBEL) was used for single-photon ionization. It was shown that soft ionization allows the reduction of fragmentation of the target analytes and the suppression of most matrix components. Therefore, the combination of photon ionization with the tandem mass spectrometry (MS/MS) capability of an ion trap yields a powerful tool for molecular ion peak detection and identification of organic trace compounds in complex matrixes. This setup was successfully tested for two different applications. The first one is the detection of security-relevant substances like explosives, narcotics, and chemical warfare agents. One test substance from each of these groups was chosen and detected successfully with single photon ionization ion trap mass spectrometry (SPI-ITMS) MS/MS measurements. Additionally, first tests were performed, demonstrating that this method is not influenced by matrix compounds. The second field of application is the detection of process gases. Here, exhaust gas from coffee roasting was analyzed in real time, and some of its compounds were identified using MS/MS studies.

  16. Complete single ionization momentum spectra for strong perturbation collisions

    International Nuclear Information System (INIS)

    Olson, R.E.; Wood, C.J.

    1997-09-01

    The combination of recoil ion and ionized electron momentum spectroscopy provides an unparalleled method to investigate the details of ion-atom collision dynamics in kinematically complete experiments. To predict singleionization scattering behavior at the level now realized by experiment, the classical trajectory three-body Monte Carlo method has been used to obtain complete momenta information for the ionized electron, recoil ion, and projectile in the collision plane defined by the incident projectile and outgoing recoil ion. Strongly coupled systems were considered where the charge state of the projectile divided by the speed of the collision q/v is greater than unity. Illustrated are 3.6 MeV/u Se 28+ and 9.5 MeV/u Ni 26+ collisions on He where experimental data are available. The theoretical results are in good agreement with these data and calculations have been performed for 165 keV/u and 506 keV/u C 6+ +He to compare results for the same q/v perturbation strengths. (orig.)

  17. Solubilities of magnesium-L-ascorbate, calcium-L-ascorbate, magnesium-L-glutamate, magnesium-D-gluconate, calcium-D-gluconate, calcium-D-heptagluconate, L-aspartic acid, and 3-nitrobenzoic acid in water

    Energy Technology Data Exchange (ETDEWEB)

    Mishelevich, Alexander [Department of Chemical Engineering, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel); Apelblat, Alexander [Department of Chemical Engineering, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel)], E-mail: apelblat@bgu.ac.il

    2008-05-15

    The solubility in water of magnesium-L-ascorbate, calcium-L-ascorbate, magnesium-L-glutamate, magnesium-D-gluconate, calcium-D-gluconate, calcium-D-heptagluconate, L-aspartic acid, and 3-nitrobenzoic acid was determined in the 278.15 K to 343.15 K temperature range. The solubility of these compounds served to permit the evaluation of the apparent molar enthalpies of solution.

  18. Solubilities of magnesium-L-ascorbate, calcium-L-ascorbate, magnesium-L-glutamate, magnesium-D-gluconate, calcium-D-gluconate, calcium-D-heptagluconate, L-aspartic acid, and 3-nitrobenzoic acid in water

    International Nuclear Information System (INIS)

    Mishelevich, Alexander; Apelblat, Alexander

    2008-01-01

    The solubility in water of magnesium-L-ascorbate, calcium-L-ascorbate, magnesium-L-glutamate, magnesium-D-gluconate, calcium-D-gluconate, calcium-D-heptagluconate, L-aspartic acid, and 3-nitrobenzoic acid was determined in the 278.15 K to 343.15 K temperature range. The solubility of these compounds served to permit the evaluation of the apparent molar enthalpies of solution

  19. Electron impact ionization of large krypton clusters

    Institute of Scientific and Technical Information of China (English)

    Li Shao-Hui; Li Ru-Xin; Ni Guo-Quan; Xu Zhi-Zhan

    2004-01-01

    We show that the detection of ionization of very large van der Waals clusters in a pulsed jet or a beam can be realized by using a fast ion gauge. Rapid positive feedback electron impact ionization and fragmentation processes,which are initially ignited by electron impact ionization of the krypton clusters with the electron current of the ion gauge, result in the appearance of a progressional oscillation-like ion spectrum, or just of a single fast event under critical conditions. Each line in the spectrum represents a correlated explosion or avalanche ionization of the clusters.The phenomena have been analysed qualitatively along with a Rayleigh scattering experiment of the corresponding cluster jet.

  20. Study of Serum Magnesium in Surgical Stress

    Directory of Open Access Journals (Sweden)

    Sandip D. Lambe

    2016-10-01

    Full Text Available Background: A deficiency of magnesium is of clinical importance in hospitalized patients. The prevalence of hypomagnesaemia is high in critically ill patients. Knowing the important role of magnesium in surgical cases, it is necessary to anticipate and diagnose magnesium deficiency prior to surgery and in the immediate postoperative period to correct it. Aims and Objectives: The aim of this study was to analyse serum magnesium levels in patients undergoing emergency surgical procedures, planned surgical procedures and normal healthy matched controls and to compare the serum magnesium levels in all the three groups. Materials and Methods: The study participants were divided into three groups: i Group I: patients undergoing emergency major surgery ii Group II: patients undergoing planned major surgery iii Group III: normal healthy controls. Serum Magnesium investigation was done by Xylidyl Blue Method using UV-1800/Shimadzu UV-Spectrophotometer. Results: The mean serum Magnesium in control group was found to be 2.16 ± 0.30 mg/dl. In patients undergoing planned surgery, pre-operative serum magnesium was normal (2.16 ± 0.22 mg/dl but decreased significantly on postoperative day 3 (1.63 ± 0.27 mg/dl and day 6 (1.97 ± 0.12 mg/dl and returned to normal level by post-operative day 9 (2.14 ± 0.14 mg/dl compared to controls. In patients undergoing emergency surgery, serum magnesium was decreased pre-operatively (1.90 ± 0.48 mg/dl.Further significant reduction was found at post-operative day 3 (1.38 ± 0.28 mg/dl, day 6 (1.59 ± 0.30 mg/dl and day 9 (1.88 ± 0.46 mg/dl compared to controls. Mean serum Magnesium overall in emergency surgery patients was reduced significantly compared to planned surgery patients. Conclusion: A transient fall in the serum Magnesium as compared to its pre-operative level was seen in every patient undergoing surgical procedure due to surgical stress. In patients undergoing emergency surgical procedure, the decrease was

  1. Low Temperature Synthesis of Magnesium Aluminate Spinel

    International Nuclear Information System (INIS)

    Lebedovskaya, E.G.; Gabelkov, S.V.; Litvinenko, L.M.; Logvinkov, D.S.; Mironova, A.G.; Odejchuk, M.A.; Poltavtsev, N.S.; Tarasov, R.V.

    2006-01-01

    The low-temperature synthesis of magnesium-aluminum spinel is carried out by a method of thermal decomposition in combined precipitated hydrates. The fine material of magnesium-aluminium spinel with average size of coherent dispersion's area 4...5 nanometers is obtained. Magnesium-aluminum spinel and initial hydrates were investigated by methods of the differential thermal analysis, the x-ray phase analysis and measurements of weight loss during the dehydration and thermal decomposition. It is established that synthesis of magnesium-aluminum spinel occurs at temperature 300 degree C by method of the x-ray phase analysis

  2. Wide Strip Casting Technology of Magnesium Alloys

    Science.gov (United States)

    Park, W.-J.; Kim, J. J.; Kim, I. J.; Choo, D.

    Extensive investigations relating to the production of high performance and low cost magnesium sheet by strip casting have been performed for the application to automotive parts and electronic devices. Research on magnesium sheet production technology started in 2004 by Research Institute of Industrial Science and Technology (RIST) with support of Pohang Iron and Steel Company (POSCO). POSCO has completed the world's first plant to manufacture magnesium coil. Another big project in order to develop wide strip casting technology for the automotive applications of magnesium sheets was started in succession.

  3. A novel method to estimate the impact parameter on a drift cell by using the information of single ionization clusters

    Energy Technology Data Exchange (ETDEWEB)

    Signorelli, G., E-mail: giovanni.signorelli@pi.infn.it [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); D' Onofrio, A. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Università di Pisa, Dipartimento di Fisica, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Venturini, M. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Scuola Normale Superiore, Piazza dei Cavalieri 7, 56126 Pisa (Italy)

    2016-07-11

    Measuring the time of each ionization cluster in drift chambers has been proposed to improve the single hit resolution, especially for very low mass tracking systems. Ad hoc formulae have been developed to combine the information from the single clusters. We show that the problem falls in a wide category of problems that can be solved with an algorithm called Maximum Possible Spacing (MPS) which has been demonstrated to find the optimal estimator. We show that the MPS approach is applicable and gives the expected results. Its application in a real tracking device, namely the MEG II cylindrical drift chamber, is discussed.

  4. Effect of oxygen on the hydrogenation properties of magnesium films

    DEFF Research Database (Denmark)

    Ostenfeld, Christopher Worsøe; Chorkendorff, Ib

    2006-01-01

    The effect of magnesium oxide on the magnesium and hydrogen desorption properties of magnesium films have been investigated. We find that by capping metallic magnesium films with oxide overlayers the apparent desorption energy of magnesium is increased from 146 kJ/mol to 314 kJ/mol. The results...... are discussed in light of previous investigations of ball-milled magnesium powders....

  5. The potential for ionic liquid electrolytes to stabilise the magnesium interface for magnesium/air batteries

    International Nuclear Information System (INIS)

    Khoo, Timothy; Howlett, Patrick C.; Tsagouria, Maureen; MacFarlane, Douglas R.; Forsyth, Maria

    2011-01-01

    Magnesium/air batteries are a possible high-energy density power source that, to date, have not received strong commercial interest due to issues with the corrosion of the magnesium and evaporation of the electrolyte. In this work we report on the use of ionic liquid based electrolytes to stabilise the metal/electrolyte interface and their impact on the electrochemical performance. Galvanostatic measurements indicate that the water content of the ionic liquid electrolyte plays an important role in the cell discharge characteristics. Surface characterisation using EIS, ATR-FTIR and powder diffraction examined the unique properties of the surface film formed on the magnesium anode.

  6. Spectroscopic study of plasma during electrolytic oxidation of magnesium- and aluminium-alloy

    International Nuclear Information System (INIS)

    Jovović, J.; Stojadinović, S.; Šišović, N.M.; Konjević, N.

    2012-01-01

    We present the results of an optical emission spectroscopy study of Plasma during Electrolytic Oxidation (PEO) of magnesium- and aluminum-alloy. Plasma electron number density N e diagnostics is performed either from the H β line shape or from the width or shift of non-hydrogenic ion lines of aluminum and magnesium. The line profile analysis of the H β suggests presence of two PEO processes characterized by relatively low electron number densities N e ≈1.2×10 15 cm −3 and N e ≈2.3×10 16 cm −3 . Apart from these two low N e processes, there is the third one related to the ejection of evaporated anode material through micro-discharge channels. This process is characterized by larger electron density N e =(1.2–1.6)10 17 cm −3 , which is detected from the shape and shift of aluminum and magnesium singly charged ion lines. Two low N e values detected from the H β and large N e measured from the widths and shift of ion lines suggest presence of three types of discharges during PEO with aluminum- and magnesium-alloy anode. On the basis of present and earlier results one can conclude that low N e processes do not depend upon anode material or electrolyte composition. The electron temperature of 4000 K and 33,000 K are determined from relative intensities of Mg I and O II lines, respectively. The attention is drawn to the possibility of N e application for T e evaluation using Saha equation what is of importance for PEO metal plasma characterization. During the course of this study, difficulties in the analysis of spectral line shapes are encountered and the ways to overcome some of the obstacles are demonstrated. -- Highlights: ► Optical emission spectroscopy of plasma during electrolytic oxidation. ► Spectral line profiles of the H-beta and non-hydrogenic singly charged ion lines of aluminum and magnesium. ► Experimental line profiles with complex structure. ► Three plasma processes involved. ► The application of Saha equation for the process

  7. Irradiation effects in magnesium and aluminium alloys

    International Nuclear Information System (INIS)

    Sturcken, E.F.

    1979-01-01

    Effects of neutron irradiation on microstructure, mechanical properties and swelling of several magnesium and aluminium alloys were studied. The neutron fluences of 2-3 X 10 22 n/cm 2 , >0.2 MeV produced displacement doses of 20 to 45 displacements per atom (dpa). Ductility of the magnesium alloys was severely reduced by irradiation induced recrystallization and precipitation of various forms. Precipitation of transmuted silicon occurred in the aluminium alloys. However, the effect on ductility was much less than for the magnesium alloys. The magnesium and aluminium alloys had excellent resistance to swelling: The best magnesium alloy was Mg/3.0 wt% Al/0.19 wt% Ca; its density decreased by only 0.13%. The best aluminium alloy was 6063, with a density decrease of 0.22%. (Auth.)

  8. Natural mineral bottled waters available on the Polish market as a source of minerals for the consumers. Part 1. Calcium and magnesium.

    Science.gov (United States)

    Gątarska, Anna; Tońska, Elżbieta; Ciborska, Joanna

    2016-01-01

    Natural mineral waters may be an essential source of calcium, magnesium and other minerals. In bottled waters, minerals occur in an ionized form which is very well digestible. However, the concentration of minerals in underground waters (which constitute the material for the production of bottled waters) varies. In view of the above, the type of water consumed is essential. The aim of the study was to estimate the calcium and magnesium contents in products available on the market and to evaluate calcium and magnesium consumption with natural mineral water by different consumer groups with an assumed volume of the consumed product. These represented forty different brands of natural mineral available waters on Polish market. These waters were produced in Poland or other European countries. Among the studied products, about 30% of the waters were imported from Lithuania, Latvia, Czech Republic, France, Italy and Germany. The content of calcium and magnesium in mineral waters was determined using flame atomic absorption spectrometry in an acetylene-air flame. Further determinations were carried out using atomic absorption spectrometer--ICE 3000 SERIES-THERMO-England, equipped with a GLITE data station, background correction (a deuterium lamp) as well as other cathode lamps. Over half of the analysed natural mineral waters were medium-mineralized. The natural mineral waters available on the market can be characterized by a varied content of calcium and magnesium and a high degree of product mineralization does not guarantee significant amounts of these components. Among the natural mineral waters available on the market, only a few feature the optimum calcium-magnesium proportion (2:1). Considering the mineralization degree of the studied products, it can be stated that the largest percentage of products with significant calcium and magnesium contents can be found in the high-mineralized water group. For some natural mineral waters, the consumption of 1 litre daily may

  9. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  10. Observation of terahertz-radiation-induced ionization in a single nano island.

    Science.gov (United States)

    Seo, Minah; Kang, Ji-Hun; Kim, Hyo-Suk; Hyong Cho, Joon; Choi, Jaebin; Min Jhon, Young; Lee, Seok; Hun Kim, Jae; Lee, Taikjin; Park, Q-Han; Kim, Chulki

    2015-05-22

    Terahertz (THz) electromagnetic wave has been widely used as a spectroscopic probe to detect the collective vibrational mode in vast molecular systems and investigate dielectric properties of various materials. Recent technological advances in generating intense THz radiation and the emergence of THz plasmonics operating with nanoscale structures have opened up new pathways toward THz applications. Here, we present a new opportunity in engineering the state of matter at the atomic scale using THz wave and a metallic nanostructure. We show that a medium strength THz radiation of 22 kV/cm can induce ionization of ambient carbon atoms through interaction with a metallic nanostructure. The prepared structure, made of a nano slot antenna and a nano island located at the center, acts as a nanogap capacitor and enhances the local electric field by two orders of magnitudes thereby causing the ionization of ambient carbon atoms. Ionization and accumulation of carbon atoms are also observed through the change of the resonant condition of the nano slot antenna and the shift of the characteristic mode in the spectrum of the transmitted THz waves.

  11. Electrolytes for magnesium electrochemical cells

    Science.gov (United States)

    Burrell, Anthony K.; Sa, Niya; Proffit, Danielle Lee; Lipson, Albert; Liao, Chen; Vaughey, John T.; Ingram, Brian J.

    2017-07-04

    An electrochemical cell includes a high voltage cathode configured to operate at 1.5 volts or greater; an anode including Mg.sup.0; and an electrolyte including an ether solvent and a magnesium salt; wherein: a concentration of the magnesium salt in the ether is 1 M or greater.

  12. Data on ionization, excitation, dissociation and dissociative ionization of targets by helium ion bombardments, (1)

    International Nuclear Information System (INIS)

    Oda, Nobuo; Urakawa, Junji

    1984-03-01

    This report presents a compilation of the experimental data on cross sections for the ionization, excitation, dissociation and dissociative ionization processes of targets in helium ion impacts on atoms and molecules under a single collision condition. These measurements were carried out in the energy range from several keV to 3.5 MeV. A systematic survey has been made on the literatures from 1975 to the end of 1982. A list of references is also given, including relevant papers published before 1975. (author)

  13. EFFECT OF MAGNESIUM SULFATE (A LAXATIVE) ON ...

    African Journals Online (AJOL)

    use with little success . Magnesium sulfate also known as Epsom salt or bitter salt is a hydrate salt with a chemical name of magnesium sulfate heptahydrate . Chemical formula is MgSO. 7HO and trade name is. Andrews liver salt. Dried magnesium sulfate is an osmotic laxative or a saline laxative that acts by increasing the.

  14. Immunological Response to Biodegradable Magnesium Implants

    Science.gov (United States)

    Pichler, Karin; Fischerauer, Stefan; Ferlic, Peter; Martinelli, Elisabeth; Brezinsek, Hans-Peter; Uggowitzer, Peter J.; Löffler, Jörg F.; Weinberg, Annelie-Martina

    2014-04-01

    The use of biodegradable magnesium implants in pediatric trauma surgery would render surgical interventions for implant removal after tissue healing unnecessary, thereby preventing stress to the children and reducing therapy costs. In this study, we report on the immunological response to biodegradable magnesium implants—as an important aspect in evaluating biocompatibility—tested in a growing rat model. The focus of this study was to investigate the response of the innate immune system to either fast or slow degrading magnesium pins, which were implanted into the femoral bones of 5-week-old rats. The main alloying element of the fast-degrading alloy (ZX50) was Zn, while it was Y in the slow-degrading implant (WZ21). Our results demonstrate that degrading magnesium implants beneficially influence the immune system, especially in the first postoperative weeks but also during tissue healing and early bone remodeling. However, rodents with WZ21 pins showed a slightly decreased phagocytic ability during bone remodeling when the degradation rate reached its maximum. This may be due to the high release rate of the rare earth-element yttrium, which is potentially toxic. From our results we conclude that magnesium implants have a beneficial effect on the innate immune system but that there are some concerns regarding the use of yttrium-alloyed magnesium implants, especially in pediatric patients.

  15. Magnesium substitution in the structure of orthopedic nanoparticles: A comparison between amorphous magnesium phosphates, calcium magnesium phosphates, and hydroxyapatites

    International Nuclear Information System (INIS)

    Nabiyouni, Maryam; Ren, Yufu; Bhaduri, Sarit B.

    2015-01-01

    As biocompatible materials, magnesium phosphates have received a lot of attention for orthopedic applications. During the last decade multiple studies have shown advantages for magnesium phosphate such as lack of cytotoxicity, biocompatibility, strong mechanical properties, and high biodegradability. The present study investigates the role of Mg +2 and Ca +2 ions in the structure of magnesium phosphate and calcium phosphate nanoparticles. To directly compare the effect of Mg +2 and Ca +2 ions on structure of nanoparticles and their biological behavior, three groups of nanoparticles including amorphous magnesium phosphates (AMPs) which release Mg +2 , calcium magnesium phosphates (CMPs) which release Mg +2 and Ca +2 , and hydroxyapatites (HAs) which release Ca +2 were studied. SEM, TEM, XRD, and FTIR were used to evaluate the morphology, crystallinity, and chemical properties of the particles. AMP particles were homogeneous nanospheres, whereas CMPs were combinations of heterogeneous nanorods and nanospheres, and HAs which contained heterogeneous nanosphere particles. Cell compatibility was monitored in all groups to determine the cytotoxicity effect of particles on studied MC3T3-E1 preosteoblasts. AMPs showed significantly higher attachment rate than the HAs after 1 day and both AMPs and CMPs showed significantly higher proliferation rate when compared to HAs after 7 days. Gene expression level of osteoblastic markers ALP, COL I, OCN, OPN, RUNX2 were monitored and they were normalized to GAPDH housekeeping gene. Beta actin expression level was monitored as the second housekeeping gene to confirm the accuracy of results. In general, AMPs and CMPs showed higher expression level of osteoblastic genes after 7 days which can further confirm the stimulating role of Mg + 2 and Ca +2 ions in increasing the proliferation rate, differentiation, and mineralization of MC3T3-E1 preosteoblasts. - Highlights: • Role of Mg 2+ and Ca 2+ ions in proliferation, and differentiation

  16. Investigation of magnesium oxychloride cement at the initial hardening stage

    Directory of Open Access Journals (Sweden)

    Averina Galina

    2018-01-01

    Full Text Available The paper investigates the process of variation of magnesium oxychloride cement deformations at the initial hardening stage depending on the activity of magnesium oxide powder which is determined by the parameters of the source material burning. Investigation is focused on magnesium cements obtained from pure magnesium hydroxide. Source materials were burnt at various temperatures with the purpose to obtain magnesium oxide powder with different activity. Regular content of hydrated phases was determined in hardened magnesium cement prepared on the basis of binders with different activity. The study reveals the influence of magnesium oxide powder activity on the process of deformation occurrence in hardened magnesium cement and its tendency to crack formation.

  17. Recrystallization of magnesium deformed at low temperatures

    International Nuclear Information System (INIS)

    Fromageau, R.; Pastol, J.L.; Revel, G.

    1978-01-01

    The recrystallization of magnesium was studied after rolling at temperatures ranging between 248 and 373 K. For zone refined magnesium the annealing behaviour as observed by electrical resistivity measurements showed two stages at about 250 K and 400 K due respectively to recrystallization and grain growth. The activation energy associated with the recrystallization stage was 0.75 +- 0.01 eV. In less pure magnesium, with nominal purity 99.99 and 99.9%, the recrystallization stage was decomposed into two substages. Activation energies were determined in relation with deformation temperature and purity. The magnesium of intermediate purity (99.99%) behaved similarly to the lowest purity metal when it was deformed at high temperature and to the purest magnesium when the deformation was made at low temperature. This behaviour was discussed in connection with the theories of Luecke and Cahn. (Auth.)

  18. Benefits of magnesium wheels for consumer cars

    Science.gov (United States)

    Frishfelds, Vilnis; Timuhins, Andrejs; Bethers, Uldis

    2018-05-01

    Advantages and disadvantages of magnesium wheels are considered based on a mechanical model of a car. Magnesium wheels are usually applied to racing cars as they provide slightly better strength/weight ratio than aluminum alloys. Do they provide notable benefits also for the everyday user when the car speeds do not exceed allowed speed limit? Distinct properties of magnesium rims are discussed. Apart from lighter weight of magnesium alloys, they are also good in dissipating the energy of vibrations. The role of energy dissipation in the rim of a wheel is estimated by a quarter car model. Improvements to safety by using the magnesium wheels are considered. Braking distance and responsiveness of the car is studied both with and without using an Anti Blocking System (ABS). Influence of rim weight on various handling parameters of the car is quantitatively tested.

  19. A review on hot tearing of magnesium alloys

    Directory of Open Access Journals (Sweden)

    Jiangfeng Song

    2016-09-01

    Full Text Available Hot tearing is often a major casting defect in magnesium alloys and has a significant impact on the quality of their casting products. Hot tearing of magnesium alloys is a complex solidification phenomenon which is still not fully understood, it is of great importance to investigate the hot tearing behaviour of magnesium alloys. This review attempts to summarize the investigations on hot tearing of magnesium alloys over the past decades. The hot tearing criteria including recently developed Kou's criterion are summarized and compared. The numeric simulation and assessing methods of hot tearing, factors influencing hot tearing, and hot tearing susceptibility (HTS of magnesium alloys are discussed.

  20. Manufacturing and characterization of magnesium alloy foils for use as anode materials in rechargeable magnesium ion batteries

    Science.gov (United States)

    Schloffer, Daniel; Bozorgi, Salar; Sherstnev, Pavel; Lenardt, Christian; Gollas, Bernhard

    2017-11-01

    The fabrication of thin foils of magnesium for use as anode material in rechargeable magnesium ion batteries is described. In order to improve its workability, the magnesium was alloyed by melting metallurgy with zinc and/or gadolinium, producing saturated solid solutions. The material was extruded to thin foils and rolled to a thickness of approximately 100 μm. The electrochemical behavior of Mg-1.63 wt% Zn, Mg-1.55 wt% Gd and Mg-1.02 wt% Zn-1.01 wt% Gd was studied in (PhMgCl)2-AlCl3/THF electrolyte by cyclic voltammetry and galvanostatic cycling in symmetrical cells. Analysis of the current-potential curves in the Tafel region and the linear region close to the equilibrium potential show almost no effect of the alloying elements on the exchange current densities (5-45 μA/cm2) and the transfer coefficients. Chemical analyses of the alloy surfaces and the electrolyte demonstrate that the alloying elements not only dissolve with the magnesium during the anodic half-cycles, but also re-deposit during the cathodic half-cycles together with the magnesium and aluminum from the electrolyte. Given the negligible corrosion rate in aprotic electrolytes under such conditions, no adverse effects of alloying elements are expected for the performance of magnesium anodes in secondary batteries.

  1. CIFOG: Cosmological Ionization Fields frOm Galaxies

    Science.gov (United States)

    Hutter, Anne

    2018-03-01

    CIFOG is a versatile MPI-parallelised semi-numerical tool to perform simulations of the Epoch of Reionization. From a set of evolving cosmological gas density and ionizing emissivity fields, it computes the time and spatially dependent ionization of neutral hydrogen (HI), neutral (HeI) and singly ionized helium (HeII) in the intergalactic medium (IGM). The code accounts for HII, HeII, HeIII recombinations, and provides different descriptions for the photoionization rate that are used to calculate the residual HI fraction in ionized regions. This tool has been designed to be coupled to semi-analytic galaxy formation models or hydrodynamical simulations. The modular fashion of the code allows the user to easily introduce new descriptions for recombinations and the photoionization rate.

  2. Lifetimes of metastable levels of singly ionized titanium: theory and experiment

    International Nuclear Information System (INIS)

    Palmeri, P; Quinet, P; Biemont, E; Gurell, J; Lundin, P; Royen, P; Mannervik, S; Norlin, L-O; Blagoev, K

    2008-01-01

    This paper presents new theoretical lifetimes of metastable levels in singly ionized titanium, Ti II. Along with the lifetimes, transition probabilities for several decay channels from these metastable levels are presented. The calculations are supported by experimental lifetime determinations of the 3d 3 b 2 D 5/2 and 3d 2 ( 3 P)4s b 2 P 3/2 levels along with revised values of the previously published lifetimes of the 3d 2 ( 3 P)4s b 4 P 5/2 and 3d 2 ( 3 P)4s b 2 P 1/2 levels originating partly from a reanalysis utilizing a recently developed method applied on the previously recorded data and partly from new measurements. The presented theoretical investigation of lifetimes of metastable levels in Ti II shows that the HFR calculations are in general compatible with measurements performed using the ion storage ring CRYRING of Stockholm University. The transition probabilities of forbidden lines derived from the new lifetime values will be useful for the diagnostics of low density laboratory or astrophysical plasmas, particularly those encountered in the strontium filament found in the ejecta of η Carinae

  3. Transport of Magnesium by a Bacterial Nramp-Related Gene

    Science.gov (United States)

    Rodionov, Dmitry A.; Freedman, Benjamin G.; Senger, Ryan S.; Winkler, Wade C.

    2014-01-01

    Magnesium is an essential divalent metal that serves many cellular functions. While most divalent cations are maintained at relatively low intracellular concentrations, magnesium is maintained at a higher level (∼0.5–2.0 mM). Three families of transport proteins were previously identified for magnesium import: CorA, MgtE, and MgtA/MgtB P-type ATPases. In the current study, we find that expression of a bacterial protein unrelated to these transporters can fully restore growth to a bacterial mutant that lacks known magnesium transporters, suggesting it is a new importer for magnesium. We demonstrate that this transport activity is likely to be specific rather than resulting from substrate promiscuity because the proteins are incapable of manganese import. This magnesium transport protein is distantly related to the Nramp family of proteins, which have been shown to transport divalent cations but have never been shown to recognize magnesium. We also find gene expression of the new magnesium transporter to be controlled by a magnesium-sensing riboswitch. Importantly, we find additional examples of riboswitch-regulated homologues, suggesting that they are a frequent occurrence in bacteria. Therefore, our aggregate data discover a new and perhaps broadly important path for magnesium import and highlight how identification of riboswitch RNAs can help shed light on new, and sometimes unexpected, functions of their downstream genes. PMID:24968120

  4. Fracture healing using degradable magnesium fixation plates and screws.

    Science.gov (United States)

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Electron capture to the continuum manifestation in fully differential cross sections for ion impact single ionization

    Science.gov (United States)

    Ciappina, M. F.; Fojón, O. A.; Rivarola, R. D.

    2018-04-01

    We present theoretical calculations of single ionization of He atoms by protons and multiply charged ions. The kinematical conditions are deliberately chosen in such a way that the ejected electron velocity matches the projectile impact velocity. The computed fully differential cross sections (FDCS) in the scattering plane using the continuum-distorted wave-eikonal initial state show a distinct peaked structure for a polar electron emission angle θ k = 0°. This element is absent when a first order theory is employed. Consequently, we can argue that this peak is a clear manifestation of a three-body effect, not observed before in FDCS. We discuss a possible interpretation of this new feature.

  6. Behaviour of magnesium and two magnesium alloys heated in a carbon dioxide flow

    International Nuclear Information System (INIS)

    Boussion, M.-L.; Darras, R.; Leclercq, D.

    1959-01-01

    Magnesium is a particularly attractive material for sheathing uranium fuel elements in nuclear reactors in order to avoid uranium hot temperature oxidation by the cooling fluid. As this cooling fluid will be carbon dioxide at the (future) Marcoule plants, a thorough study of magnesium and magnesium alloys behaviour when heated by carbon dioxide at a 400 C temperature, have been completed. Tests on three materials (Mg, Mg-Zr and Mg-Zr-Zn) have been performed with CO 2 up to a temperature of 550 C, at atmospheric pressure in the presence of a certain amount of oxygen and nitrogen (in order to study the influence of these impurities), and at a pressure of 15 kg / cm 2 . Oxidation results are detailed. Reprint of a paper published in 'Revue de Metallurgie', LVI, n. 1, 1959, p. 61-67

  7. Magnesium and related low alloys

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, J; Caillat, R; Darras, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In the first part the authors examine the comparative corrosion of commercial magnesium, of a magnesium-zirconium alloy (0,4 per cent {<=} Zr {<=} 0,7 per cent) of a ternary magnesium-zinc-zirconium alloy (0,8 per cent {<=} Zn {<=} 1,2 per cent) and of english 'Magnox type' alloys, in dry carbon dioxide-free air, in damp carbon dioxide-free air, and in dry and damp carbon dioxide, at temperatures from 300 to 600 deg. C. In the second part the structural stability of these materials is studied after annealings, of 10 to 1000 hours at 300 to 450 deg. C. Variations in grain after these heat treatments and mechanical stretching properties at room temperature are presented. Finally various creep rate and life time diagrams are given for these materials, for temperatures ranging from 300 to 450 deg. C. (author) [French] Dans une premiere partie les auteurs etudient la corrosion comparee du magnesium commercial, d'un alliage magnesium-zirconium (0,4 pour cent {<=} Zr {<=} 0,7 pour cent), d'un alliage ternaire magnesium-zinc-zirconium (0,8 pour cent {<=} Zn {<=} 1,2 pour cent), et d'alliages anglais 'type Magnox', dans l'air sec decarbonate, l'air humide decarbonate, le gaz carbonique sec et humide a des temperatures de 300 a 600 deg. C. Dans une seconde partie, est etudiee la stabilite structurale de ces materiaux apres des recuits de 300 a 450 deg. C, et de 10 a 1000 heures. Sont presentees les variations, apres ces traitements thermiques, de la grosseur du grain, et des caracteristiques mecaniques de traction a la temperature ambiante. Enfin, quelques diagrammes de vitesse de fluage et de durees de vie sont presentes sur ces materiaux pour des temperatures variant entre 300 et 450 deg. C. (auteur)

  8. Multi-functional magnesium alloys containing interstitial oxygen atoms.

    Science.gov (United States)

    Kang, H; Choi, H J; Kang, S W; Shin, S E; Choi, G S; Bae, D H

    2016-03-15

    A new class of magnesium alloys has been developed by dissolving large amounts of oxygen atoms into a magnesium lattice (Mg-O alloys). The oxygen atoms are supplied by decomposing titanium dioxide nanoparticles in a magnesium melt at 720 °C; the titanium is then completely separated out from the magnesium melt after solidification. The dissolved oxygen atoms are located at the octahedral sites of magnesium, which expand the magnesium lattice. These alloys possess ionic and metallic bonding characteristics, providing outstanding mechanical and functional properties. A Mg-O-Al casting alloy made in this fashion shows superior mechanical performance, chemical resistance to corrosion, and thermal conductivity. Furthermore, a similar Mg-O-Zn wrought alloy shows high elongation to failure (>50%) at room temperature, because the alloy plastically deforms with only multiple slips in the sub-micrometer grains (alloys are expected to open a new paradigm in commercial alloy design.

  9. Dose-response relationship between dietary magnesium intake, serum magnesium concentration and risk of hypertension: a systematic review and meta-analysis of prospective cohort studies.

    Science.gov (United States)

    Han, Hedong; Fang, Xin; Wei, Xin; Liu, Yuzhou; Jin, Zhicao; Chen, Qi; Fan, Zhongjie; Aaseth, Jan; Hiyoshi, Ayako; He, Jia; Cao, Yang

    2017-05-05

    The findings of prospective cohort studies are inconsistent regarding the association between dietary magnesium intake and serum magnesium concentration and the risk of hypertension. We aimed to review the evidence from prospective cohort studies and perform a dose-response meta-analysis to investigate the relationship between dietary magnesium intake and serum magnesium concentrations and the risk of hypertension. We searched systematically PubMed, EMBASE and the Cochrane Library databases from October 1951 through June 2016. Prospective cohort studies reporting effect estimates with 95% confidence intervals (CIs) for hypertension in more than two categories of dietary magnesium intake and/or serum magnesium concentrations were included. Random-effects models were used to combine the estimated effects. Nine articles (six on dietary magnesium intake, two on serum magnesium concentration and one on both) of ten cohort studies, including 20,119 cases of hypertension and 180,566 participates, were eligible for inclusion in the meta-analysis. We found an inverse association between dietary magnesium intake and the risk of hypertension [relative risk (RR) = 0.92; 95% CI: 0.86, 0.98] comparing the highest intake group with the lowest. A 100 mg/day increment in magnesium intake was associated with a 5% reduction in the risk of hypertension (RR = 0.95; 95% CI: 0.90, 1.00). The association of serum magnesium concentration with the risk of hypertension was marginally significant (RR = 0.91; 95% CI: 0.80, 1.02). Current evidence supports the inverse dose-response relationship between dietary magnesium intake and the risk of hypertension. However, the evidence about the relationship between serum magnesium concentration and hypertension is limited.

  10. Exoelectron emission from magnesium borate glass ceramics

    International Nuclear Information System (INIS)

    Kawamoto, Takamichi; Yanagisawa, Hideo; Nakamichi, Hiroshi; Kikuchi, Riichi; Kawanishi, Masaharu.

    1986-01-01

    Thermally stimulated exoelectron emission (TSEE) of a magnesium borate glass ceramics was investigated for its application to dosemetric use. It has been found that the TSEE glow patterns of the magnesium borate glass ceramics as well as a Li 2 B 4 O 7 glass ceramics depend on the kind of the radiation used and that the heat resistance of the magnesium borate glass ceramics is higher than that of the Li 2 B 4 O 7 glass ceramics. Therefore, the TSEE glow patterns of the magnesium borate glass ceramics indicate a possibility to be used as the dose measurement for each kind of radiation in the mixed radiation field. (author)

  11. Multiple ionization effects in M X-ray emission induced by heavy ions

    International Nuclear Information System (INIS)

    Wang, Xing; Zhao, Yongtao; Cheng, Rui; Zhou, Xianming; Xu, Ge; Sun, Yuanbo; Lei, Yu; Wang, Yuyu; Ren, Jieru; Yu, Yang; Li, Yongfeng; Zhang, Xiaoan; Li, Yaozong; Liang, Changhui; Xiao, Guoqing

    2012-01-01

    M-shell ionization of tungsten by Ar 12+ ions were investigated in the energy range of 1.2–3.0 MeV. The measurements were also implemented for H, He and Xe ions as a comparative study. A significant shift of the M X-ray lines to the higher energy side caused by multiple ionizations, which was verified by the analysis of the intensity ratios of M γ and M αβ , was observed. The total experimental cross sections of tungsten were compared with the PWBA and ECPSSR theoretical predictions, which are based on two extreme assumptions, namely, single ionization and full ionization. -- Highlights: ► Projectiles with low velocity (near Bohr velocity). ► A significant shift of the M X-ray lines to the higher energy side. ► A large enhancement in the M 3 fluorescence yield. ► Theoretical predictions based on single ionization and full ionization.

  12. Magnesium doping of boron nitride nanotubes

    Science.gov (United States)

    Legg, Robert; Jordan, Kevin

    2015-06-16

    A method to fabricate boron nitride nanotubes incorporating magnesium diboride in their structure. In a first embodiment, magnesium wire is introduced into a reaction feed bundle during a BNNT fabrication process. In a second embodiment, magnesium in powder form is mixed into a nitrogen gas flow during the BNNT fabrication process. MgB.sub.2 yarn may be used for superconducting applications and, in that capacity, has considerably less susceptibility to stress and has considerably better thermal conductivity than these conventional materials when compared to both conventional low and high temperature superconducting materials.

  13. Special metallurgy - the electrical butt-welding by flashing of sintered magnesium-magnesium oxide composites (1963)

    International Nuclear Information System (INIS)

    Charleux, J.

    1963-01-01

    Electrical resistance welding has become quite important since World War II because of the need of a high yield in aeronautical production. Progress has been due in particular to the improvements made in electronically controlled apparatus making possible the automatic control of welding. For the butt-welding of sections requiring either a high production rate or a high quality weld, the flash butt-welding system has been very much developed these last few years. The use of this welding method is of great importance in the field of the bonding of oxidisable metals such as magnesium or aluminium and its alloys, because the welded joint is free from oxides. This study consists of general considerations on the flash-welding process with regard to temperature distribution in the parts during welding, and to electrical phenomena connected with flashing. Besides this general or theoretical section, we have applied the welding process to the bonding of sintered magnesium, a magnesium-magnesium oxide composite, whose use as a structural element in nuclear reactors is considered. (author) [fr

  14. Magnesium supplement in pregnancy-induced hypertension: effects on maternal and neonatal magnesium and calcium homeostasis

    DEFF Research Database (Denmark)

    Rudnicki, M; Frølich, A; Fischer-Rasmussen, W

    1991-01-01

    The objective of this study was to evaluate the effect of low dose magnesium supplement upon maternal and fetal serum levels of mineral status in pregnancies complicated with hypertension (PIH). Twenty-five patients with PIH agreed to participate and were randomly allocated, in a double-blind man......The objective of this study was to evaluate the effect of low dose magnesium supplement upon maternal and fetal serum levels of mineral status in pregnancies complicated with hypertension (PIH). Twenty-five patients with PIH agreed to participate and were randomly allocated, in a double...... period despite a significant increased loss of calcium during the first 24 h of inclusion. Low dose maternal magnesium treatment did not cause neonatal hypocalcemia....

  15. Impact of total ionizing dose on the electromagnetic susceptibility of a single bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Jarrix, S.; Raoult, J.; Blain, A.; Dusseau, L.; Chatry, N.; Calvel, P.; Hoffmann, P.

    2012-01-01

    Space or military electronic components are subject to both electromagnetic fields and total ionizing dose. This paper deals with the electromagnetic susceptibility of a discrete low frequency transistor subject to total ionizing dose deposition. The electromagnetic susceptibility is investigated on both non-irradiated and irradiated transistors mounted in common emitter configuration. The change in susceptibility to 100 MHz-1.5 GHz interferences lights up a synergy effect between near field electromagnetic waves and total ionizing dose. Physical mechanisms leading to changes in signal output are detailed. (authors)

  16. Lattice Boltzmann method for weakly ionized isothermal plasmas

    International Nuclear Information System (INIS)

    Li Huayu; Ki, Hyungson

    2007-01-01

    In this paper, a lattice Boltzmann method (LBM) for weakly ionized isothermal plasmas is presented by introducing a rescaling scheme for the Boltzmann transport equation. Without using this rescaling, we found that the nondimensional relaxation time used in the LBM is too large and the LBM does not produce physically realistic results. The developed model was applied to the electrostatic wave problem and the diffusion process of singly ionized helium plasmas with a 1-3% degree of ionization under an electric field. The obtained results agree well with theoretical values

  17. Practical calculation of amplitudes for electron-impact ionization

    International Nuclear Information System (INIS)

    McCurdy, C. William; Horner, Daniel A.; Rescigno, Thomas N.

    2001-01-01

    An integral expression that is formally valid only for short-range potentials is applied to the problem of calculating the amplitude for electron-impact ionization. It is found that this expression provides a practical and accurate path to the calculation of singly differential cross sections for electron-impact ionization. Calculations are presented for the Temkin-Poet and collinear models for ionization of hydrogen by electron impact. An extension of the finite-element approach using the discrete-variable representation, appropriate for potentials with discontinuous derivatives like the Temkin-Poet interaction, is also presented

  18. Association of Magnesium Intake with High Blood Pressure in Korean Adults: Korea National Health and Nutrition Examination Survey 2007–2009

    Science.gov (United States)

    Choi, Mi-Kyeong; Bae, Yun Jung

    2015-01-01

    Background Magnesium is known to lower the risk of cardiovascular disease. However, studies on its relationship with hypertension, a single and common cause of various chronic diseases, are limited and their findings are not consistent. The purpose of the present study is to identify the relationship between magnesium intake and high blood pressure (HBP) risk in Koreans. Methods This research is a cross-sectional study based on the 2007~2009 Korean National Health and Nutritional Examination Survey data. This study investigated 11,685 adults aged over 20 to examine their general characteristics, anthropometry and blood pressure. Daily magnesium intake was analyzed using the 24-hour dietary recall method. To calculate the odds ratio (OR) of HBP risk (130/85 mmHg or over) according to the quartile of magnesium intake (mg/1000kcal) together with its 95% confidence interval (CI), multivariable logistic regression analysis was performed. Results No significant association between dietary magnesium intake and the risk of HBP was found. In obese women, particularly, after adjusting relevant factors, the adjusted odds ratio of HBP prevalence in the highest magnesium intake quartile was 0.40 compared with the lowest magnesium intake quartile (95% CI = 0.25~0.63, P for trend = 0.0014). Women, especially obese women, were found to have a negative relationship of magnesium intake with HBP. Conclusions The present results indicate that sufficient magnesium intake could be useful in decreasing the high blood pressure risk of obese women. PMID:26075385

  19. The spectrum of singly ionized scandium, Sc II

    International Nuclear Information System (INIS)

    Johansson, S.; Litzen, U.

    1980-01-01

    The Sc II spectrum, emitted from a pulsed hollow-cathode discharge, has been studied in the region 1100-11 000 A, where 777 lines have been classified. 168 levels are now known, belonging to configurations of the types 3dnl, 4snl and 4p 2 . Parametric studies have been made for a number of configurations. A determination of the ionization limit from the configurations 3d4f, 5f and 5g gives the value 103 237.1+-2 cm -1 . (Auth.)

  20. Ionization and charge exchange in atom collision with multicharged ion

    International Nuclear Information System (INIS)

    Presnyakov, L.P.; Uskov, D.B.

    1984-01-01

    Single-electron ionization and charge exchange are considered in collisions of an atom with an ion of charge Z> or =3 and at velocities v>Z -1 /sup // 3 . The approach is based on the Keldysh quasiclassical method. The ionization and charge exchange processes are described within the framework of a single formalism. Effects of rotation and translation are taken into account. The calculated total and partial cross sections agree well with the available experimental data. OFF

  1. Critically Evaluated Energy Levels, Spectral Lines, Transition Probabilities, and Intensities of Singly Ionized Vanadium (V ii)

    Energy Technology Data Exchange (ETDEWEB)

    Saloman, Edward B. [Dakota Consulting, Inc., 1110 Bonifant Street, Suite 310, Silver Spring, MD 20910 (United States); Kramida, Alexander [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2017-08-01

    The energy levels, observed spectral lines, and transition probabilities of singly ionized vanadium, V ii, have been compiled. The experimentally derived energy levels belong to the configurations 3 d {sup 4}, 3 d {sup 3} ns ( n  = 4, 5, 6), 3 d {sup 3} np , and 3 d {sup 3} nd ( n  = 4, 5), 3 d {sup 3}4 f , 3 d {sup 2}4 s {sup 2}, and 3 d {sup 2}4 s 4 p . Also included are values for some forbidden lines that may be of interest to the astrophysical community. Experimental Landé g -factors and leading percentages for the levels are included when available, as well as Ritz wavelengths calculated from the energy levels. Wavelengths and transition probabilities are reported for 3568 and 1896 transitions, respectively. From the list of observed wavelengths, 407 energy levels are determined. The observed intensities, normalized to a common scale, are provided. From the newly optimized energy levels, a revised value for the ionization energy is derived, 118,030(60) cm{sup −1}, corresponding to 14.634(7) eV. This is 130 cm{sup −1} higher than the previously recommended value from Iglesias et al.

  2. Magnesium sulphate for fetal neuroprotection

    DEFF Research Database (Denmark)

    Bickford, Celeste D; Magee, Laura A; Mitton, Craig

    2013-01-01

    of cerebral palsy (CP) averted and quality-adjusted life years (QALYs). RESULTS: From a health system and a societal perspective, respectively, a savings of $2,242 and $112,602 is obtained for each QALY gained and a savings of $30,942 and $1,554,198 is obtained for each case of CP averted when magnesium......BACKGROUND: The aim of this study was to assess the cost-effectiveness of administering magnesium sulphate to patients in whom preterm birth at ... sensitivity analyses were used to compare the administration of magnesium sulphate with the alternative of no treatment. Two separate cost perspectives were utilized in this series of analyses: a health system and a societal perspective. In addition, two separate measures of effectiveness were utilized: cases...

  3. Study of the effect of low-power pulse laser on arc plasma and magnesium alloy target in hybrid welding by spectral diagnosis technique

    Science.gov (United States)

    Liu, Liming; Hao, Xinfeng

    2008-10-01

    In order to study the effect of laser pulses on arc plasma and target metal in the hybrid welding process, the spectra of the plasmas in the welding process of magnesium alloys are analysed in this paper. The acquisition system of plasma spectra is set up and the spectral lines of welding plasma are acquired. Compared with tungsten-inert gas (TIG) welding, the intensities of the spectral lines of magnesium increase sharply while those of Ar decrease for strong evaporation and ionization of magnesium alloys in low-power laser/arc hybrid welding. The electron temperature and density are estimated by the Boltzmann plot method and the Stark broadening effect. The result shows that the electron temperature of arc plasma in the hybrid welding process is much lower than that in TIG welding, especially in the laser beam-affected zone. In contrast, the electron density of the plasma is enhanced. The influences of laser parameters on electron temperature are also studied. The changes in electron temperature and density indicate that the effect of laser pulse on the target metal is the dominant factor influencing the electron temperature and density in low-power laser/arc hybrid welding.

  4. Effect of initial-state target polarization on the single ionization of helium by 1-keV electron impact

    International Nuclear Information System (INIS)

    Sun Shi-Yan; Ma Xiao-Yan; Li Xia; Miao Xiang-Yang; Jia Xiang-Fu

    2012-01-01

    We report new results of triple differential cross sections for the single ionization of helium by 1-KeV electron impact at the ejection energy of 10 eV. Investigations have been made for both the perpendicular plane and the plane perpendicular to the momentum transfer geometries. The present calculation is based on the three-Coulomb wave function. Here we have also incorporated the effect of target polarization in the initial state. A comparison is made between the present calculation with the results of other theoretical methods and a recent experiment [Dürr M, Dimopoulou C, Najjari B, Dorn A, Bartschat K, Bray I, Fursa D V, Chen Z, Madison D H and Ullrich J 2008 Phys. Rev. A 77 032717]. At an impact energy of 1 KeV, the target polarization is found to induce a substantial change of the cross section for the ionization process. We observe that the effect of target polarization plays a dominant role in deciding the shape of triple differential cross sections. (atomic and molecular physics)

  5. Improved biological performance of magnesium by micro-arc oxidation

    Directory of Open Access Journals (Sweden)

    W.H. Ma

    2015-03-01

    Full Text Available Magnesium and its alloys have recently been used in the development of lightweight, biodegradable implant materials. However, the corrosion properties of magnesium limit its clinical application. The purpose of this study was to comprehensively evaluate the degradation behavior and biomechanical properties of magnesium materials treated with micro-arc oxidation (MAO, which is a new promising surface treatment for developing corrosion resistance in magnesium, and to provide a theoretical basis for its further optimization and clinical application. The degradation behavior of MAO-treated magnesium was studied systematically by immersion and electrochemical tests, and its biomechanical performance when exposed to simulated body fluids was evaluated by tensile tests. In addition, the cell toxicity of MAO-treated magnesium samples during the corrosion process was evaluated, and its biocompatibility was investigated under in vivo conditions. The results of this study showed that the oxide coating layers could elevate the corrosion potential of magnesium and reduce its degradation rate. In addition, the MAO-coated sample showed no cytotoxicity and more new bone was formed around it during in vivo degradation. MAO treatment could effectively enhance the corrosion resistance of the magnesium specimen and help to keep its original mechanical properties. The MAO-coated magnesium material had good cytocompatibility and biocompatibility. This technique has an advantage for developing novel implant materials and may potentially be used for future clinical applications.

  6. Urinary and plasma magnesium and risk of ischemic heart disease

    NARCIS (Netherlands)

    Joosten, Michel M.; Gansevoort, Ron T.; Mukamal, Kenneth J.; van der Harst, Pim; Geleijnse, Johanna M.; Feskens, Edith J. M.; Navis, Gerjan; Bakker, Stephan J. L.

    Background: Previous studies on dietary magnesium and risk of ischemic heart disease (IHD) have yielded inconsistent results, in part because of a lack of direct measures of actual magnesium uptake. Urinary excretion of magnesium, an indicator of dietary magnesium uptake, might provide more

  7. A review on magnesium alloys as biodegradable materials

    Science.gov (United States)

    Gu, Xue-Nan; Zheng, Yu-Feng

    2010-06-01

    Magnesium alloys attracted great attention as a new kind of degradable biomaterials. One research direction of biomedical magnesium alloys is based on the industrial magnesium alloys system, and another is the self-designed biomedical magnesium alloys from the viewpoint of biomaterials. The mechanical, biocorrosion properties and biocompatibilities of currently reported Mg alloys were summarized in the present paper, with the mechanical properties of bone tissue, the healing period postsurgery, the pathophysiology and toxicology of the alloying elements being discussed. The strategy in the future development of biomedical Mg alloys was proposed.

  8. Matrix-assisted laser-desorption/ionization mass spectrometric imaging of olanzapine in a single hair using esculetin as a matrix.

    Science.gov (United States)

    Wang, Hang; Wang, Ying; Wang, Ge; Hong, Lizhi

    2017-07-15

    Matrix-assisted laser desorption/ionization-mass spectrometric imaging (MALDI-MSI) for the analysis of intact hair is a powerful tool for monitoring changes in drug consumption. The embedding of a low drug concentration in the hydrophobic hair matrix makes it difficult to extract and detect, and requires an improved method to increase detection sensitivity. In this study, an MSI method using MALDI-Fourier transform ion cyclotron resonance was developed for direct identification and imaging of olanzapine in hair samples using the positive ion mode. Following decontamination, scalp hair samples from an olanzapine user were scraped from the proximal to the distal end three times, and 5mm hair sections were fixed onto an Indium-Tin-Oxide (ITO)-coated microscopic glass slide. Esculetin (6,7-dihydroxy-2H-chromen-2-one) was used as a new hydrophobic matrix to increase the affinity, extraction and ionization efficiency of olanzapine in the hair samples. The spatial distribution of olanzapine was observed using five single hairs from the same drug user. This matrix improves the affinity of olanzapine in hair for molecular imaging with mass spectrometry. This method may provide a detection power for olanzapine to the nanogram level per 5mm hair. Time course changes in the MSI results were also compared with quantitative HPLC-MS/MS for each 5mm segment of single hair shafts selected from the MALDI target. MALDI imaging intensities in single hairs showed good semi-quantitative correlation with the results from conventional HPLC-MS/MS. MALDI-MSI is suitable for monitoring drug intake with a high time resolution. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Extremely-high vacuum pressure measurement by laser ionization

    International Nuclear Information System (INIS)

    Kokubun, Kiyohide

    1991-01-01

    Laser ionization method has the very high sensitivity for detecting atoms and molecules. Hurst et al. successfully detected a single Cs atom by means of resonance ionization spectroscopy developed by them. Noting this high sensitivity, the authors have attempted to apply the laser ionization method to measure gas pressure, particularly in the range down to extremely high vacuum. At present, hot cathode ionization gauges are used for measuring gas pressure down to ultrahigh vacuum, however, those have a number of disadvantages. The pressure measurement using lasers does not have such disadvantages. The pressure measurement utilizing the laser ionization method is based on the principle that when laser beam is focused through a lens, the amount of atom or molecule ions generated in the focused space region is proportional to gas pressure. In this paper, the experimental results are presented on the nonresonant multiphoton ionization characteristics of various kinds of gases, the ion detection system with high sensitivity and an extremely high vacuum system prepared for the laser ionization experiment. (K.I.)

  10. Synthesis of Nano-Light Magnesium Hydride for Hydrogen Storage ...

    African Journals Online (AJOL)

    Abstract. Nano-light magnesium hydride that has the capability for hydrogen storage was synthesized from treatment of magnesium ribbon with hydrogen peroxide. The optimum time for complete hydrogenation of the magnesium hydride was 5 hours.

  11. Electron Impact Ionization of C60

    International Nuclear Information System (INIS)

    Duenser, B.; Lezius, M.; Scheier, P.; Deutsch, H.; Maerk, T.D.

    1995-01-01

    Absolute partial and total cross sections for the electron impact ionization of C 60 have been measured using a novel approach for the absolute calibration. The results obtained reveal not only an anomalous large parent ion cross section (as compared to the other ionization channels), but also anomalies for the production of multiply charged parent and fragment ions. This special behavior has its origin in the specific electronic and geometric structure of C 60 . Semiclassical calculations for singly charged ions support the measured data

  12. Hydrogenations of alloys and intermetallic compounds of magnesium

    International Nuclear Information System (INIS)

    Gavra, Z.

    1981-08-01

    A kinetic and thermodynamic study of the hydrogenation of alloys and intermetallic compounds of magnesium is presented. It was established that the addition of elements of the IIIA group (Al, Ga, In) to magnesium catalyses its hydrogenation. This is explained by the mechanism of diffusion of magnesium cation vacancies. The hydride Mg 2 NiH 4 was characterized by thermal analysis, x-ray diffraction and NMR measurements. The possibility of forming pseudo-binary compounds of Mg 2 Ni by the substitution of nickel or magnesium was examined. The hydrogenation of the inter-metallic compounds of the Mg-Al system was investigated. It was found that the addition of indium and nickel affected the hydrogenation kinetics. A preliminary study of the hydrogenation of various binary and ternary alloys of magnesium was carried out. (Author)

  13. Reprint of: Improved cytotoxicity testing of magnesium materials

    International Nuclear Information System (INIS)

    Fischer, Janine; Pröfrock, Daniel; Hort, Norbert; Willumeit, Regine; Feyerabend, Frank

    2011-01-01

    Metallic magnesium (Mg) and its alloys are highly suitable for medical applications as biocompatible and biodegradable implant materials. Magnesium has mechanical properties similar to bone, stimulates bone regeneration, is an essential non-toxic element for the human body and degrades completely within the body environment. In consequence, magnesium is a promising candidate as implant material for orthopaedic applications. Protocols using the guideline of current ISO standards should be carefully evaluated when applying them for the characterization of the cytotoxic potential of degradable magnesium materials. For as-cast material we recommend using 10 times more extraction medium than recommended by the ISO standards to obtain reasonable results for reliable cytotoxicity rankings of degradable materials in vitro. In addition primary isolated human osteoblasts or mesenchymal stem cells should be used to test magnesium materials.

  14. Reprint of: Improved cytotoxicity testing of magnesium materials

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Janine [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Department for Structural Research on Macromolecules, Max-Planck Str. 1, D - 21502 Geesthacht (Germany); Proefrock, Daniel [Helmholtz-Zentrum Geesthacht, Institute for Coastal Research, Department for Marine Bioanalytical Chemistry, Max-Planck Str. 1, D - 21502 Geesthacht (Germany); Hort, Norbert [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Department for Magnesium Processing, Max-Planck Str. 1, D - 21502 Geesthacht (Germany); Willumeit, Regine; Feyerabend, Frank [Helmholtz-Zentrum Geesthacht, Institute of Materials Research, Department for Structural Research on Macromolecules, Max-Planck Str. 1, D - 21502 Geesthacht (Germany)

    2011-12-15

    Metallic magnesium (Mg) and its alloys are highly suitable for medical applications as biocompatible and biodegradable implant materials. Magnesium has mechanical properties similar to bone, stimulates bone regeneration, is an essential non-toxic element for the human body and degrades completely within the body environment. In consequence, magnesium is a promising candidate as implant material for orthopaedic applications. Protocols using the guideline of current ISO standards should be carefully evaluated when applying them for the characterization of the cytotoxic potential of degradable magnesium materials. For as-cast material we recommend using 10 times more extraction medium than recommended by the ISO standards to obtain reasonable results for reliable cytotoxicity rankings of degradable materials in vitro. In addition primary isolated human osteoblasts or mesenchymal stem cells should be used to test magnesium materials.

  15. Double electron ionization in Compton scattering of high energy photons by helium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M.Y.; Mikhailov, A.I. [St. Petersburg Nuclear Physics Institute, Gatchina (Russian Federation)

    1995-08-01

    The cross section for double-electron ionization of two-electron atoms and ions in Compton scattering of high energy photons is calculated. It is demonstrated that its dependence on the incoming photon frequency is the same as that for single-electron ionization. The ratio of {open_quotes}double-to-single{close_quotes} ionization in Compton scattering was found to be energy independent and almost identical with the corresponding value for photoionization. For the He atom it is 1.68%. This surprising result deserves experimental verification.

  16. K-shell ionization and double-ionization of Au atoms with 1.33 MeV photons

    International Nuclear Information System (INIS)

    Belkacem, A.; Dauvergne, D.; Feinberg, B.; Ionescu, D.; Maddi, J.; Sorensen, A.H.

    2000-01-01

    At relativistic energies, the cross section for the atomic photoelectric effect drops off as does the cross section for liberating any bound electron through Compton scattering. However, when the photon energy exceeds twice the rest mass of the electron, ionization may proceed via electron-positron pair creation. We used 1.33 MeV photons impinging on Au thin foils to study double K-shell ionization and vacuum-assisted photoionization. The preliminary results yield a ratio of vacuum-assisted photoionization and pair creation of 2x10 -3 , a value that is substantially higher than the ratio of photo double ionization to single photoionization that is found to be 0.5-1x10 -4 . Because of the difficulties and large error bars associated with the small cross sections additional measurements are needed to minimize systematic errors

  17. Process for selectively concentrating the radioactivity of thorium containing magnesium slag

    International Nuclear Information System (INIS)

    Wilson, D.A.; Christiansen, S.H.; Simon, J.; Morin, D.W.

    1993-01-01

    In a process for separating magnesium from a magnesium slag using water and carbon dioxide, the improvement described comprises: (a) forming an aqueous magnesium slurry from the magnesium slag, which slag contains radioactive thorium and its daughters, and water; (b) solubilizing magnesium from the magnesium slurry by reacting the aqueous magnesium slurry with carbon dioxide wherein the carbon dioxide is at a pressure from greater than ambient to about 1,000 psig (about 7,000 kPa); (c) selectively concentrating by filtering the radioactive thorium and its daughters such that the radioactive thorium and its daughters are separated from the solubilized magnesium filtrate; and (d) reducing volume and/or weight of radioactive solids for disposal as radioactive waste

  18. Magnesium Cermets and Magnesium-Beryllium Alloys; Cermets au magnesium et au magnesium-beryllium; Metallokeramicheskie magnievye i magnievo-berillievye splavy; Cermets de magnesio y aleaciones de magnesio y berillio

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, V. E.; Zelenskij, V. F.; Fajfer, S. I.; Zhdanov, S. M.; Maksimenko, V. I.; Savchenko, V. I. [Fiziko-Tekhnicheskij Institut an USSR, Khar' kov, SSSR (Russian Federation)

    1963-11-15

    The paper describes some results of work on the development of magnesium-magnesium oxide cermets and of super heat-resistant magnesiumberyllium alloys produced by powder metallurgical methods. The introduction of even a minute quantity of finely dispersed magnesium oxide into magnesium results in a strengthening of the material, the degree of which increases with increased magnesium oxide concentration, although variation of this concentration within the limits of 0.3 to 5 wt.% has a comparatively slight effect on the corresponding variation in the short-term strength over the whole range of temperatures investigated. At 20{sup o}C, in the case of the cermets, {sigma}{sub {beta}} = 28 to 31 kg/mm{sup 2} and {delta} = 3 .5 to 4.5%; at 500{sup o}C {sigma}{sub {beta}} = 2.6 to 3.2 kg/mm{sup 2} and {delta} =30 to 40%. The positive effect of the finely dispersed oxide phase is particularly evident in protracted tests. For magnesium cermets, {sigma} (300)/100 = 2.2 kg/mm{sup 2}. Characteristic of the mixtures is the high thermal stability of the strength properties, linked chiefly with the thermodynamic stability of the strength-giving oxide phase in the metal matrix. The use of powder metallurgical methods has yielded super heat-resistant magnesium-beryllium alloys containing heightened concentrations of beryllium (PMB alloys). In their strength characteristics PMB alloys are close to Mg-MgO cermets, but the magnesium-beryllium alloys have a degree and duration of resistance to high temperature oxidation which exceeds the corresponding qualities of the magnesium alloys at present known. Thus, in air of 580{sup o}C, PMB alloys with 2 to 5% beryllium maintain a high resistance to oxidation for a period of over 12000 to 14000 h. This long-term heat resistance is chiefly a result of the amount of beryllium in the alloy, and increases with increasing beryllium content. PMB alloys are also marked by high resistance to short bursts of overheating. Magnesium cermets and

  19. Magnesium in Disease Prevention and Overall Health12

    Science.gov (United States)

    Volpe, Stella Lucia

    2013-01-01

    Magnesium is the fourth most abundant mineral and the second most abundant intracellular divalent cation and has been recognized as a cofactor for >300 metabolic reactions in the body. Some of the processes in which magnesium is a cofactor include, but are not limited to, protein synthesis, cellular energy production and storage, reproduction, DNA and RNA synthesis, and stabilizing mitochondrial membranes. Magnesium also plays a critical role in nerve transmission, cardiac excitability, neuromuscular conduction, muscular contraction, vasomotor tone, blood pressure, and glucose and insulin metabolism. Because of magnesium’s many functions within the body, it plays a major role in disease prevention and overall health. Low levels of magnesium have been associated with a number of chronic diseases including migraine headaches, Alzheimer’s disease, cerebrovascular accident (stroke), hypertension, cardiovascular disease, and type 2 diabetes mellitus. Good food sources of magnesium include unrefined (whole) grains, spinach, nuts, legumes, and white potatoes (tubers). This review presents recent research in the areas of magnesium and chronic disease, with the goal of emphasizing magnesium’s role in disease prevention and overall health. PMID:23674807

  20. Laser ablation of ceramic Al{sub 2}O{sub 3} at 193 nm and 248 nm: The importance of single-photon ionization processes

    Energy Technology Data Exchange (ETDEWEB)

    Pelaez, R. J.; Afonso, C. N. [Laser Processing Group, Instituto de Optica, CSIC, Serrano 121, Madrid 28006 (Spain); Bator, M.; Lippert, T. [General Energy Research Department, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2013-06-14

    The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al{sub 2}O{sub 3} in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to Almost-Equal-To 2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al{sup +} ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.

  1. There is chronic latent magnesium deficiency in apparently healthy university students

    OpenAIRE

    Hermes Sales, Cristiane; Azevedo Nascimento, Débora; Queiroz Medeiros, Anna Cecília; Costa Lima, Kênio; Campos Pedrosa, Lucia Fátima; Colli, Célia

    2014-01-01

    Introduction: Magnesium is an essential micronutrient for human body, and its deficiency has been associated with risk of non-communicable diseases. Objective: Assessment of magnesium status, and evaluation of the frequency of magnesium deficiency in a group of healthy adults. Methods: Plasma and erythrocyte magnesium levels, and magnesium intake were determined in 115 students (55 women and 60 men), from a public university in Brazil. Results: The medians of magnesium concentration in plasma...

  2. Direct-reading spectrochemical analysis of magnesium alloys

    International Nuclear Information System (INIS)

    Roca Adell, M.

    1964-01-01

    A Quantometer has been applied to the determination of aluminum, berylium, calcium, iron, silicon and zinc in magnesium alloys Magnox, after the conversion of the samples to the oxide. For the aluminum, whose concentration is relatively high, the conducting briquets technique with an interrupted discharge is employed, using the magnesium as the internal standard. For the other elements a total burning method with direct current arc is employed, using also the magnesium as the internal standard. (Author) 7 refs

  3. Detection of minimum-ionizing particles in hydrogenated amorphous silicon

    International Nuclear Information System (INIS)

    Kaplan, S.N.; Fujieda, I.; Perez-Mendez, V.; Qureshi, S.; Ward, W.; Street, R.A.

    1987-09-01

    Based on previously-reported results of the successful detection of alpha particles and 1- and 2-MeV protons with hydrogenated amorphous silicon (a-Si : H) diodes, detection of a single minimum-ionizing particle will require a total sensitive thickness of approximately 100 to 150 μm, either in the form of a single thick diode, or as a stack of several thinner diodes. Signal saturation at high dE/dx makes it necessary to simulate minimum ionization in order to evaluate present detectors. Two techniques, using pulsed infrared light, and pulsed x-rays, give single-pulse signals large enough for direct measurements. A third, using beta rays, requires multiple-transit signal averaging to produce signals measurable above noise. Signal amplitudes from the a-Si : H limit at 60% of the signal size from Si crystals extrapolated to the same thickness. This is consistent with an a-Si : H radiation ionization energy, W = 6 eV/electron-hole pair. Beta-ray signals are observed at the expected amplitude

  4. Constraints on Weathering from Riverine Magnesium Isotope Ratios

    DEFF Research Database (Denmark)

    Wiechert, Uwe; Ullmann, Clemens Vinzenz; Meixner, Anette

    and industrialized regions, the d26Mg values mirror the lithologies of the catchment areas: the Danubian catchment is dominated by carbonatic lithologies and in the Danube dissolved magnesium exhibits the most negative d26Mg values between -1.85 and -1.70 ‰. The mainly siliceous catchment of the river Elbe causes....... Simple mass balance calculations on the basis of the magnesium isotopes obtained for the investigated rivers imply 26 to 59 % magnesium derived from carbonatic lithologies and 41 to 74 % magnesium from siliceous lithologies. This is in contrast to estimates using conventional methods for the tribute...

  5. Magnesium analysis. Spectrophotometric determination of chromium

    International Nuclear Information System (INIS)

    Anon.

    Chromium determination in magnesium used in uranium fabrication by magnesiothermics, applicable for chromium content between 2 to 10 ppm. Magnesium is dissolved in sulfuric acid, oxidized by potassium permanganate, the excess of permanganate is eliminated by sodium nitride. Spectrophotometry at 540 nm of the chromium (VI)-diphenylcarbazide complex [fr

  6. Semi-solid twin-roll casting process of magnesium alloy sheets

    International Nuclear Information System (INIS)

    Watari, H.; Davey, K.; Rasgado, M.T. Alonso; Haga, T.; Koga, N.

    2004-01-01

    An experimental approach has been performed to ascertain the effectiveness of semi-solid strip casting using a horizontal twin roll caster. The demand for light-weight products with high strength has grown recently due to the rapid development of automobile and aircraft technology. One key to such development has been utilization of magnesium alloys, which can potentially reduce the total product weight. However, the problems of utilizing magnesium alloys are still mainly related to high manufacturing cost. One of the solutions to this problem is to develop magnesium casting-rolling technology in order to produce magnesium sheet products at competitive cost for commercial applications. In this experiment, magnesium alloy AZ31B was used to ascertain the effectiveness of semi-solid roll strip casting for producing magnesium alloy sheets. The temperature of the molten magnesium, and the roll speeds of the upper and lower rolls, (which could be changed independently), were varied to find an appropriate manufacturing condition. Rolling and heat treatment conditions were changed to examine which condition would be appropriate for producing wrought magnesium alloys with good formability. Microscopic observation of the crystals of the manufactured wrought magnesium alloys was performed. It has been found that a limiting drawing ratio of 2.7 was possible in a warm deep drawing test of the cast magnesium alloy sheets after being hot rolled

  7. Near-Threshold Ionization of Argon by Positron Impact

    Science.gov (United States)

    Babij, T. J.; Machacek, J. R.; Murtagh, D. J.; Buckman, S. J.; Sullivan, J. P.

    2018-03-01

    The direct single-ionization cross section for Ar by positron impact has been measured in the region above the first ionization threshold. These measurements are compared to semiclassical calculations which give rise to a power law variation of the cross section in the threshold region. The experimental results appear to be in disagreement with extensions to the Wannier theory applied to positron impact ionization, with a smaller exponent than that calculated by most previous works. In fact, in this work, we see no difference in threshold behavior between the positron and electron cases. Possible reasons for this discrepancy are discussed.

  8. Calculation of ionization within the close-coupling formalism

    International Nuclear Information System (INIS)

    Bray, I.; Fursa, D.V.

    1996-05-01

    A method for calculation of differential ionization cross sections from theories that use the close-coupling expansions for the total wave functions is presented. It is shown how from a single such calculation elastic, excitation, and ionization cross sections may be extracted using solely the T-matrix elements arising from solution of the coupled equations. To demonstrate the applicability of this formalism, the convergent close-coupling (CCC) theory is systematically applied at incident energies of 150-600 eV to the calculation of e-He ionization. Comparison with available measurements is generally very good. 50 refs., 17 figs

  9. Differential cross sections for single ionization of H2 by 75-keV proton impact

    International Nuclear Information System (INIS)

    Chowdhury, U.; Schulz, M.; Madison, D. H.

    2011-01-01

    We have calculated triply differential cross sections (TDCS) and doubly differential cross sections (DDCS) for single ionization of H 2 by 75-keV proton impact using the molecular three-body distorted-wave-eikonal initial-state (M3DW-EIS) approach. Previously published measured DDCS (differential in the projectile scattering angle and integrated over the ejected electron angles) found pronounced structures at relatively large angles that were interpreted as an interference resulting from the two-centered potential of the molecule. Theory treating H 2 as atomic H multiplied by a molecular interference factor only predicts the observed structure when assumptions are made about the molecular orientation. Here we apply the M3DW-EIS method, which does not rely on such an ad hoc approach, but rather treats the interference from first principles.

  10. Features of solid solutions composition in magnesium with yttrium alloys

    International Nuclear Information System (INIS)

    Drits, M.E.; Rokhlin, L.L.; Tarytina, I.E.

    1983-01-01

    Additional data on features of yttrium solid solutions composition in magnesium in the course of their decomposition investigation in the case of aging are obtianed. The investigation has been carried out on the base of a binary magnesium-yttrium alloy the composition of which has been close to maximum solubility (at eutectic temperature) and magnesium-yttrium alloys additionally doped with zinc. It is shown that higher yttrium solubility in solid magnesium than it has been expected, issueing from the difference in atomic radii of these metals indicates electron yttrium-magnesium atoms interaction. In oversaturated magnesium-yttrium solid solutions at earlier decomposition stages Mg 3 Cd type ordering is observed. At aging temperatures up to 250 deg C and long exposures corresponding to highest strengthening in oversaturated magnesium yttrium solid solutions a rhombic crystal lattice phase with three symmetric orientations is formed

  11. A Case of a Magnesium Oxide Bezoar.

    Science.gov (United States)

    Iwamuro, Masaya; Saito, Shunsuke; Yoshioka, Masao; Urata, Haruo; Ueda, Kumiko; Yamamoto, Kazuhide; Okada, Hiroyuki

    2018-06-06

    A 75-year-old Japanese woman presented with nausea and appetite loss. Computed tomography showed a radiopaque substance in the stomach. Esophagogastroduodenoscopy revealed bezoars in the stomach, which were endoscopically retrieved. The bezoars were mainly composed of magnesium and oxide. Although bezoar formation associated with magnesium oxide consumption is infrequently encountered, the present case indicates that pharmacobezoar should be considered among the differential diagnoses in patients who demonstrate a radiopaque mass in the digestive tract and have a history of magnesium oxide use.

  12. Optical Imaging of Ionizing Radiation from Clinical Sources.

    Science.gov (United States)

    Shaffer, Travis M; Drain, Charles Michael; Grimm, Jan

    2016-11-01

    Nuclear medicine uses ionizing radiation for both in vivo diagnosis and therapy. Ionizing radiation comes from a variety of sources, including x-rays, beam therapy, brachytherapy, and various injected radionuclides. Although PET and SPECT remain clinical mainstays, optical readouts of ionizing radiation offer numerous benefits and complement these standard techniques. Furthermore, for ionizing radiation sources that cannot be imaged using these standard techniques, optical imaging offers a unique imaging alternative. This article reviews optical imaging of both radionuclide- and beam-based ionizing radiation from high-energy photons and charged particles through mechanisms including radioluminescence, Cerenkov luminescence, and scintillation. Therapeutically, these visible photons have been combined with photodynamic therapeutic agents preclinically for increasing therapeutic response at depths difficult to reach with external light sources. Last, new microscopy methods that allow single-cell optical imaging of radionuclides are reviewed. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Role of magnesium on the biomimetic deposition of calcium phosphate

    Science.gov (United States)

    Sarma, Bimal K.; Sarma, Bikash

    2016-10-01

    Biomimetic depositions of calcium phosphate (CaP) are carried out using simulated body fluid (SBF), calcifying solution and newly developed magnesium containing calcifying solution. Calcium phosphate has a rich phase diagram and is well known for its excellent biocompatibility and bioactivity. The most common phase is hydroxyapatite (HAp), an integral component of human bone and tooth, widely used in orthopedic and dental applications. In addition, calcium phosphate nanoparticles show promise for the targeted drug delivery. The doping of calcium phosphate by magnesium, zinc, strontium etc. can change the protein uptake by CaP nanocrystals. This work describes the role of magnesium on the nucleation and growth of CaP on Ti and its oxide substrates. X-ray diffraction studies confirm formation of HAp nanocrystals which closely resemble the structure of bone apatite when grown using SBF and calcifying solution. It has been observed that magnesium plays crucial role in the nucleation and growth of calcium phosphate. A low magnesium level enhances the crystallinity of HAp while higher magnesium content leads to the formation of amorphous calcium phosphate (ACP) phase. Interestingly, the deposition of ACP phase is rapid when magnesium ion concentration in the solution is 40% of calcium plus magnesium ions concentration. Moreover, high magnesium content alters the morphology of CaP films.

  14. Magnesium and diltiazem relaxes phenylephrine-precontracted rat aortic rings

    Science.gov (United States)

    Dogan, Mustafa; Peker, Recep O.; Donmez, Soner; Gokalp, Osman

    2012-01-01

    Perioperative vasospasm during cardiovascular surgery is a challenging problem. Several vasodilator agents are frequently utilized for its prevention in surgical practice. Magnesium and diltiazem both have known potential vasorelaxant effects. We planned to compare the efficacy of diltiazem and magnesium in relieving phenylephrine-precontracted rat aortic rings. Ten young adult female Wistar albino rats weighing 230–260 g were used in this study. The aortic rings in the organ bath equilibrated and reached their baseline tension. Precontraction was induced by 0.001 mmol/l phenylephrine and cumulative concentration–relaxation curves were obtained by consecutively increasing the addition of either diltiazem (10−6-0.1 mmol/l) or magnesium (0.1–10 mmol/l). The mean maximal relaxation responses observed by diltiazem and magnesium on separate aortic rings were 90 ± 3 and 53 ± 2%, respectively. The calculated EC50 of diltiazem was 0.01035 mmol/l, whereas the EC50 of magnesium was 4.064 mmol/l (P < 0.05). Both magnesium and diltiazem produced vasorelaxation on phenylephrine-precontracted rat aortic rings in this study, but the potency of diltiazem regarding the EC50 value was significantly higher than that of magnesium. Magnesium could be a candidate together with diltiazem to inhibit vasospasm on arterial grafts during coronary bypass surgery. PMID:22523136

  15. Effects of ionizing radiation on cell-matrix interactions at the single molecule level

    Energy Technology Data Exchange (ETDEWEB)

    Lauer, Florian

    2015-04-20

    Single molecule microscopy is a technology that allows for accurate assessment of the location and motion of single fluorescent molecules, even in the context of observations on living biological samples. In the present thesis, a flexible analysis tool for single molecule data as obtained in biological experiments was established. The development of a tool to faithfully detect and localize diffraction-limited images of individual fluorescent probes was necessary since data acquired under cell cultivation conditions that account for a three-dimensional microenvironment as experienced physiologically by cells in native tissue poses a challenge not faced ordinarily. After design, implementation, quantitative tests using simulations for comparisons and verification, and evaluation of the different steps of the analysis procedure including local background estimation, local noise estimation, de-noising approaches, detection, localization, and post-processing, analysis capabilities were utilized to evaluate the impact of x-ray irradiation on the plasma membrane architecture of U2OS human osteosarcoma cells as assessed by tracking individual fluorescent lipid-mimetic dye molecules diffusing in the outer membrane leaflet. It was shown that lateral diffusion in the plasma membrane is well described as two-phase anomalous subdiffusion and presence of 3D extracellular matrix leads to lower anomalous exponents of the fast fraction in comparison to monolayer cell culture. Interestingly, even high single-dose (25 Gy) treatments known to induce membrane-mediated apoptosis in tumor microvessel endothelium via membrane viscosity enhancing ceramide generation were not observed to alter membrane architecture in U2OS cells which can be related to amplifying, feedback-driven redox-signaling in the endothelium absent in U2OS. In summary, the sensitive and accurate framework developed in this thesis to assess minute changes of plasma membrane located dynamic processes did not uncover a

  16. Effects of ionizing radiation on cell-matrix interactions at the single molecule level

    International Nuclear Information System (INIS)

    Lauer, Florian

    2015-01-01

    Single molecule microscopy is a technology that allows for accurate assessment of the location and motion of single fluorescent molecules, even in the context of observations on living biological samples. In the present thesis, a flexible analysis tool for single molecule data as obtained in biological experiments was established. The development of a tool to faithfully detect and localize diffraction-limited images of individual fluorescent probes was necessary since data acquired under cell cultivation conditions that account for a three-dimensional microenvironment as experienced physiologically by cells in native tissue poses a challenge not faced ordinarily. After design, implementation, quantitative tests using simulations for comparisons and verification, and evaluation of the different steps of the analysis procedure including local background estimation, local noise estimation, de-noising approaches, detection, localization, and post-processing, analysis capabilities were utilized to evaluate the impact of x-ray irradiation on the plasma membrane architecture of U2OS human osteosarcoma cells as assessed by tracking individual fluorescent lipid-mimetic dye molecules diffusing in the outer membrane leaflet. It was shown that lateral diffusion in the plasma membrane is well described as two-phase anomalous subdiffusion and presence of 3D extracellular matrix leads to lower anomalous exponents of the fast fraction in comparison to monolayer cell culture. Interestingly, even high single-dose (25 Gy) treatments known to induce membrane-mediated apoptosis in tumor microvessel endothelium via membrane viscosity enhancing ceramide generation were not observed to alter membrane architecture in U2OS cells which can be related to amplifying, feedback-driven redox-signaling in the endothelium absent in U2OS. In summary, the sensitive and accurate framework developed in this thesis to assess minute changes of plasma membrane located dynamic processes did not uncover a

  17. Telomere Homeostasis: Interplay with Magnesium

    Directory of Open Access Journals (Sweden)

    Donogh Maguire

    2018-01-01

    Full Text Available Telomere biology, a key component of the hallmarks of ageing, offers insight into dysregulation of normative ageing processes that accompany age-related diseases such as cancer. Telomere homeostasis is tightly linked to cellular metabolism, and in particular with mitochondrial physiology, which is also diminished during cellular senescence and normative physiological ageing. Inherent in the biochemistry of these processes is the role of magnesium, one of the main cellular ions and an essential cofactor in all reactions that use ATP. Magnesium plays an important role in many of the processes involved in regulating telomere structure, integrity and function. This review explores the mechanisms that maintain telomere structure and function, their influence on circadian rhythms and their impact on health and age-related disease. The pervasive role of magnesium in telomere homeostasis is also highlighted.

  18. The road to magnesium diboride thin films, Josephson junctions and SQUIDs

    International Nuclear Information System (INIS)

    Brinkman, Alexander; Mijatovic, Dragana; Hilgenkamp, Hans; Rijnders, Guus; Oomen, Ingrid; Veldhuis, Dick; Roesthuis, Frank; Rogalla, Horst; Blank, Dave H A

    2003-01-01

    The remarkably high critical temperature at which magnesium diboride (MgB 2 ) undergoes transition to the superconducting state, T c ∼ 40 K, has aroused great interest and has encouraged many groups to explore the properties and application potential of this novel superconductor. For many electronic applications and further basic studies, the availability of superconducting thin films is of great importance. Several groups have succeeded in fabricating superconducting MgB 2 films. An overview of the deposition techniques for MgB 2 thin film growth will be given, with a special focus on the in situ two-step process. Although, meanwhile, many problems to obtain suitable films have been solved, such as oxygen impurities and magnesium volatility, the question of how single-phase epitaxial films can be grown still remains. The possibility of growing single-crystalline epitaxial films will be discussed from the deposition conditions' point of view as well as substrate choice. Necessary conditions are discussed and possible routes are reviewed. The applicability of MgB 2 in superconducting electronic devices depends on the possibility of making well-controlled, i.e., reproducible and stable, Josephson junctions. The first attempts to make MgB 2 -MgO-MgB 2 ramp-type junctions and SQUIDs from MgB 2 nanobridges are discussed

  19. Yttrium ion implantation on the surface properties of magnesium

    International Nuclear Information System (INIS)

    Wang, X.M.; Zeng, X.Q.; Wu, G.S.; Yao, S.S.

    2006-01-01

    Owing to their excellent physical and mechanical properties, magnesium and its alloys are receiving more attention. However, their application has been limited to the high reactivity and the poor corrosion resistance. The aim of the study was to investigate the beneficial effects of ion-implanted yttrium using a MEVVA ion implanter on the surface properties of pure magnesium. Isothermal oxidation tests in pure O 2 at 673 and 773 K up to 90 min indicated that the oxidation resistance of magnesium had been significantly improved. Surface morphology of the oxide scale was analyzed using scanning electron microscope (SEM). Auger electron spectroscopy (AES) and X-ray diffraction (XRD) analyses indicated that the implanted layer was mainly composed of MgO and Y 2 O 3 , and the implanted layer with a duplex structure could decrease the inward diffusion of oxygen and reduce the outward diffusion of Mg 2+ , which led to improving the oxidation resistance of magnesium. Potentiodynamic polarization curves were used to evaluate the corrosion resistance of the implanted magnesium. The results show yttrium implantation could enhance the corrosion resistance of implanted magnesium compared with that of pure magnesium

  20. Alloying principles for magnesium base heat resisting alloys

    International Nuclear Information System (INIS)

    Drits, M.E.; Rokhlin, L.L.; Oreshkina, A.A.; Nikitina, N.I.

    1982-01-01

    Some binary systems of magnesium-base alloys in which solid solutions are formed, are considered for prospecting heat resistant alloys. It is shown that elements having essential solubility in solid magnesium strongly decreasing with temperature should be used for alloying maqnesium base alloys with high strength properties at increased temperatures. The strengthening phases in these alloys should comprise essential quantity of magnesium and be rather refractory

  1. 40 CFR 721.9513 - Modified magnesium silicate polymer (generic).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Modified magnesium silicate polymer... Specific Chemical Substances § 721.9513 Modified magnesium silicate polymer (generic). (a) Chemical... as modified magnesium silicate polymer (PMN P-98-604) is subject to reporting under this section for...

  2. Effect of magnesium treatment and glucose levels on delayed cerebral ischemia in patients with subarachnoid hemorrhage: a substudy of the Magnesium in Aneurysmal Subarachnoid Haemorrhage trial (MASH-II).

    Science.gov (United States)

    Leijenaar, Jolien F; Dorhout Mees, Sanne M; Algra, Ale; van den Bergh, Walter M; Rinkel, Gabriel J E

    2015-10-01

    Magnesium treatment did not improve outcome in patients with aneurysmal subarachnoid haemorrhage in the Magnesium in Aneurysmal Subarachnoid Haemorrhage II trial. We hypothesized that high glucose levels may have offset a potential beneficial effect to prevent delayed cerebral ischemia. We investigated if magnesium treatment led to less delayed cerebral ischemia and if glucose levels interacted with magnesium treatment in the Magnesium in Aneurysmal Subarachnoid Haemorrhage II trial. To investigate the effect of magnesium treatment on occurrence of delayed cerebral ischemia and the interaction between glucose levels and magnesium treatment in subarachnoid hemorrhage patients. The Magnesium in Aneurysmal Subarachnoid Haemorrhage was a phase III randomized placebo-controlled trial assessing the effect of magnesium sulphate on clinical outcome in aneurysmal subarachnoid hemorrhage patients. For the current study, we included only the patients admitted to the University Medical Centre-Utrecht. We calculated hazard ratios for occurrence of delayed cerebral ischemia in patients treated with magnesium vs. placebo for the entire study population, and separately in the subgroups of patients with high and low mean fasting and mean daily glucose levels until onset of delayed cerebral ischemia. We used the cross-product of magnesium and glucose in the regression analysis to evaluate whether an interaction between magnesium and glucose existed. We included 616 patients: 307 received magnesium and 309 placebo; 156 patients had delayed cerebral ischemia. Hazard ratio for magnesium on occurrence of delayed cerebral ischemia was 1·0 (95% confidence interval: 0·7-1·4). Results were similar in patients with low or high fasting or daily glucose levels. We found no interactions between magnesium treatment and high fasting (P = 0·54) and daily glucose (P = 0·60). Magnesium treatment did not reduce the risk of delayed cerebral ischemia in patients with aneurysmal

  3. Blood compatibility of magnesium and its alloys.

    Science.gov (United States)

    Feyerabend, Frank; Wendel, Hans-Peter; Mihailova, Boriana; Heidrich, Stefanie; Agha, Nezha Ahmad; Bismayer, Ulrich; Willumeit-Römer, Regine

    2015-10-01

    Blood compatibility analysis in the field of biomaterials is a highly controversial topic. Especially for degradable materials like magnesium and its alloys no established test methods are available. The purpose of this study was to apply advanced test methodology for the analysis of degrading materials to get a mechanistic insight into the corrosion process in contact with human blood and plasma. Pure magnesium and two magnesium alloys were analysed in a modified Chandler-Loop setup. Standard clinical parameters were determined, and a thorough analysis of the resulting implant surface chemistry was performed. The contact of the materials to blood evoked an accelerated inflammatory and cell-induced osteoconductive reaction. Corrosion products formed indicate a more realistic, in vivo like situation. The active regulation of corrosion mechanisms of magnesium alloys by different cell types should be more in the focus of research to bridge the gap between in vitro and in vivo observations and to understand the mechanism of action. This in turn could lead to a better acceptance of these materials for implant applications. The presented study deals with the first mechanistic insights during whole human blood contact and its influence on a degrading magnesium-based biomaterial. The combination of clinical parameters and corrosion layer analysis has been performed for the first time. It could be of interest due to the intended use of magnesium-based stents and for orthopaedic applications for clinical applications. An interest for the readers of Acta Biomaterialia may be given, as one of the first clinically approved magnesium-based devices is a wound-closure device, which is in direct contact with blood. Moreover, for orthopaedic applications also blood contact is of high interest. Although this is not the focus of the manuscript, it could help to rise awareness for potential future applications. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All

  4. Synergistic effects of total ionizing dose on single event upset sensitivity in static random access memory under proton irradiation

    International Nuclear Information System (INIS)

    Xiao Yao; Guo Hong-Xia; Zhang Feng-Qi; Zhao Wen; Wang Yan-Ping; Zhang Ke-Ying; Ding Li-Li; Luo Yin-Hong; Wang Yuan-Ming; Fan Xue

    2014-01-01

    Synergistic effects of the total ionizing dose (TID) on the single event upset (SEU) sensitivity in static random access memories (SRAMs) were studied by using protons. The total dose was cumulated with high flux protons during the TID exposure, and the SEU cross section was tested with low flux protons at several cumulated dose steps. Because of the radiation-induced off-state leakage current increase of the CMOS transistors, the noise margin became asymmetric and the memory imprint effect was observed. (interdisciplinary physics and related areas of science and technology)

  5. Inclusive and exclusive cross sections for multiple ionization by fast, highly charged ions in the independent-electron approximation

    International Nuclear Information System (INIS)

    Ben-Itzhak, I.; Gray, T.J.; Legg, J.C.; McGuire, J.H.

    1988-01-01

    Cross sections for the ionization of n of N electrons with equal single-electron ionization probability P are considered. When both N and the projectile charge q are large, the cross sections for single and double ionization are both found to be approximately linear in q at 1 MeVamu. The ratio of double-to-single-ionization cross sections is independent of q. Moreover, first-order perturbation theory for the single-electron ionization probability P, which varies as q 2 , is found to be applicable due to the damping of contributions with large P caused by factors of (1-P)/sup N/ - /sup n/. For large P there are differences between the inclusive probability P and the probability NP commonly used for a target with N electrons. Both of these probabilities differ significantly from the exclusive probability NP(1-P)/sup N/ -1 for the ionization of only one electron. For large N and large q, the exclusive ionization probabilities for removing exactly n of the N electrons tend to be concentrated in somewhat separate ranges of impact parameters b, defining impact-parameter ''windows.'' The windows which we obtain using the quantum-mechanical semiclassical-Coulomb-approximation (SCA) probabilities are similar to those using classical Monte Carlo calculations. Model calculations, based on analytic fits to the SCA probabilities, are used to obtain approximate analytic expressions for single- and double-ionization cross sections and for the impact-parameter windows

  6. Enzymatic, urease-mediated mineralization of gellan gum hydrogel with calcium carbonate, magnesium-enriched calcium carbonate and magnesium carbonate for bone regeneration applications.

    Science.gov (United States)

    Douglas, Timothy E L; Łapa, Agata; Samal, Sangram Keshari; Declercq, Heidi A; Schaubroeck, David; Mendes, Ana C; der Voort, Pascal Van; Dokupil, Agnieszka; Plis, Agnieszka; De Schamphelaere, Karel; Chronakis, Ioannis S; Pamuła, Elżbieta; Skirtach, Andre G

    2017-12-01

    Mineralization of hydrogel biomaterials is considered desirable to improve their suitability as materials for bone regeneration. Calcium carbonate (CaCO 3 ) has been successfully applied as a bone regeneration material, but hydrogel-CaCO 3 composites have received less attention. Magnesium (Mg) has been used as a component of calcium phosphate biomaterials to stimulate bone-forming cell adhesion and proliferation and bone regeneration in vivo, but its effect as a component of carbonate-based biomaterials remains uninvestigated. In the present study, gellan gum (GG) hydrogels were mineralized enzymatically with CaCO 3 , Mg-enriched CaCO 3 and magnesium carbonate to generate composite biomaterials for bone regeneration. Hydrogels loaded with the enzyme urease were mineralized by incubation in mineralization media containing urea and different ratios of calcium and magnesium ions. Increasing the magnesium concentration decreased mineral crystallinity. At low magnesium concentrations calcite was formed, while at higher concentrations magnesian calcite was formed. Hydromagnesite (Mg 5 (CO 3 ) 4 (OH) 2 .4H 2 O) formed at high magnesium concentration in the absence of calcium. The amount of mineral formed and compressive strength decreased with increasing magnesium concentration in the mineralization medium. The calcium:magnesium elemental ratio in the mineral formed was higher than in the respective mineralization media. Mineralization of hydrogels with calcite or magnesian calcite promoted adhesion and growth of osteoblast-like cells. Hydrogels mineralized with hydromagnesite displayed higher cytotoxicity. In conclusion, enzymatic mineralization of GG hydrogels with CaCO 3 in the form of calcite successfully reinforced hydrogels and promoted osteoblast-like cell adhesion and growth, but magnesium enrichment had no definitive positive effect. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  7. The Magnesium Industry Today…The Global Perspective

    Science.gov (United States)

    Patzer, Greg

    World demand for magnesium will show a decline in 2009. The outlook for 2010, which is guardedly optimistic, will be for a resumption of slow growth. The industry has seen marked changes in the sources of supply for primary and alloyed magnesium in recent years. Technological advances in magnesium continue at a strong pace as does interest in the material as a substitute for other light metals. The automotive segment remains the end-use area with the largest growth potential, if for no other reason than the size and quantity of the potential materials substitution applications. However, the shrinkage of that market, particularly in North America will have a definite impact on expectations for magnesium. The 3C market (computers, communications & consumer electronics) will continue to show above average growth. Other niche markets related to medical and construction industries also offer potential.

  8. QUALITY OF YOGHURTS FROM GOAT'S MILK ENRICHED WITH MAGNESIUM CHLORIDE

    Directory of Open Access Journals (Sweden)

    Agata Znamirowska

    2015-02-01

    Full Text Available Goat’s milk can be enriched with magnesium in the form of chloride before pasteurization with a save dose, i.e. 20 mg of magnesium for 100 g of milk. Higher doses of magnesium can lead to coagulation of proteins since together with the increase of the dose of fortification there increases general acidity while pH of milk decreases. Together with the increase of the dose of fortification of yoghurts with magnesium there was shown an essential proportional increase of acidity and hardness of curds persisting for 21 days of storage. Enriching goat’s milk yoghurts with magnesium decreased the intensity of „goat” smell and aftertaste and did not cause a change in colour. The most favourable solution is the production of goat’s milk yoghurts enriched with 10-20 mg of magnesium in the form of magnesium chloride. Such doses of enrichment caused successive lowering of perceptibility of „goat” aftertaste and smell together with extension of storage time.

  9. Serum Magnesium Levels in Non-Pregnant, Pregnant And Pre ...

    African Journals Online (AJOL)

    The objective of this study was to compare the serum magnesium levels in normal pregnancy and pregnancy complicated by pre-eclampsia since magnesium has been implicated in the pathogenesis of vascular dysfunction. We measured serum magnesium levels in patients with pre-eclampsia (n=36), patients with normal ...

  10. Magnesium for Hydrogen Storage

    DEFF Research Database (Denmark)

    Vigeholm, B.; Kjøller, John; Larsen, Bent

    1980-01-01

    The reaction of hydrogen with commercially pure magnesium powder (above 99.7%) was investigated in the temperature range 250–400 °C. Hydrogen is readily sorbed above the dissociation pressure. During the initial exposure the magnesium powder sorbs hydrogen slowly below 400 °C but during the second...... that the particles do not disintegrate is explained by a sintering process at the working temperatures. Exposure to air does not impair the sorption ability; on the contrary, it appears that surface oxidation plays an important role in the reaction. Some handling problems, e.g. the reaction of the hydride with water...

  11. Ionizing radiation from tobacco

    International Nuclear Information System (INIS)

    Westin, J.B.

    1987-01-01

    Accidents at nuclear power facilities seem inevitably to bring in their wake a great deal of concern on the part of both the lay and medical communities. Relatively little attention, however, is given to what may be the largest single worldwide source of effectively carcinogenic ionizing radiation: tobacco. The risk of cancer deaths from the Chernobyl disaster are tobacco smoke is discussed

  12. Macrokinetics of magnesium sulfite oxidation inhibited by ascorbic acid

    International Nuclear Information System (INIS)

    Lidong, Wang; Yongliang, Ma; Wendi, Zhang; Qiangwei, Li; Yi, Zhao; Zhanchao, Zhang

    2013-01-01

    Graphical abstract: Ascorbic acid is used as an inhibitor to retard the oxidation rate of magnesium sulfite. It shows that the oxidation rate would decrease greatly with the rise of initial ascorbic acid concentration, which provides a useful reference for sulfite recovery in magnesia desulfurization. -- Highlights: • We studied the kinetics of magnesium sulfite oxidation inhibited by ascorbic acid. • The oxidation process was simulated by a three-phase model and proved by HPLC–MS. • We calculated the kinetic parameters of intrinsic oxidation of magnesium sulfite. -- Abstract: Magnesia flue gas desulfurization is a promising process for small to medium scale industrial coal-fired boilers in order to reduce sulfur dioxide emissions, in which oxidation control of magnesium sulfite is of great importance for the recycling of products. Effects of four inhibitors were compared by kinetic experiments indicating that ascorbic acid is the best additive, which retards the oxidation process of magnesium sulfite in trace presence. The macrokinetics of magnesium sulfite oxidation inhibited by ascorbic acid were studied. Effects of the factors, including ascorbic acid concentration, magnesium sulfite concentration, oxygen partial pressure, pH, and temperature, were investigated in a stirred reactor with bubbling. The results show that the reaction rate is −0.55 order in ascorbic acid, 0.77 in oxygen partial pressure, and zero in magnesium sulfite concentration, respectively. The apparent activation energy is 88.0 kJ mol −1 . Integrated with the kinetic model, it is concluded that the oxidation rate of magnesium sulfite inhibited by ascorbic acid is controlled by the intrinsic chemical reaction. The result provides a useful reference for sulfite recovery in magnesia desulfurization

  13. Ionization of a multilevel atom by ultrashort laser pulses

    International Nuclear Information System (INIS)

    Andreev, A. V.; Stremoukhov, S. Yu.; Shutova, O. A.

    2010-01-01

    Specific features of ionization of single atoms by laser fields of a near-atomic strength are investigated. Calculations are performed for silver atoms interacting with femtosecond laser pulses with wavelengths λ = 800 nm (Ti:Sapphire) and λ = 1.064 μm (Nd:YAG). The dependences of the probability of ionization and of the form of the photoelectron energy spectra on the field of laser pulses for various values of their duration are considered. It is shown that the behavior of the probability of ionization in the range of subatomic laser pulse fields is in good agreement with the Keldysh formula. However, when the field strength attains values close to the atomic field strength, the discrepancies in these dependences manifested in a decrease in the ionization rate (ionization stabilization effect) or in its increase (accelerated ionization) are observed. These discrepancies are associated with the dependence of the population dynamics of excited discrete energy levels of the atom on the laser pulse field amplitude.

  14. Corrosion of magnesium and some magnesium alloys in gas cooled reactors; Corrosion du magnesium et de certains de ses alliages dans les piles refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Caillat, R; Darras, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The results of corrosion tests on magnesium and some magnesium alloys (Mg-Zr and Mg-Zr-Zn) in moist air (like G1 reactor) and in CO{sub 2}: (like G2, G3, EDF1 reactors) are reported. The maximum temperature for exposure of magnesium to moist air without any risk of corrosion is 350 deg. C. Indeed, the oxidation rate follows a linear law above 350 deg. C although it reaches a constant level and keeps on very low under 350 deg. C. However, as far as corrosion is concerned this temperature limit can be raised up to 500 deg. C if moist air is very slightly charged with fluorinated compounds. Under pressure of CO{sub 2}, these three materials oxidate much more slowly even if 500 deg. C is reached. The higher is the temperature, the higher is the constant level of the weight increase and the quicker is reached this one. However, Mg-Zr alloy behaves quite better than pure magnesium and especially than Mg-Zr-Zn alloy. (author)Fren. [French] On expose essentiellement les resultats d'etudes sur la corrosion du magnesium et de certains de ses alliages (Mg-Zr et Mg-Zr-Zn) dans l'air humide (cas de la pile G1) et dans le gaz carbonique (cas des piles G2, G3, EDF1, etc...). La temperature limite d'exposition du magnesium dans l'air humide sans risque de corrosion se situe a 350 deg. C; en effet l'oxydation a un caractere lineaire au-dessus de cette temperature, alors qu'elle atteint un palier et reste tres limitee au-dessous de 350 deg. C. Du point de vue de la corrosion, cette temperature limite d'emploi peut cependant etre elevee jusqu'a 500 deg. C si l'on introduit dans l'air humide de tres faibles teneurs de composes fluores. Dans le gaz carbonique sous pression, l'oxydation est beaucoup plus faible, meme jusqu'a 50g. C pour les trois materiaux: l'augmentation de poids atteint un palier d'autant plus eleve et ceci d'autant plus rapidement que la temperature est elle-meme plus elevee. Cependant, l'alliage Mg-Zr se comporte nettement mieux que le magnesium pur et surtout que l

  15. Corrosion of magnesium and some magnesium alloys in gas cooled reactors; Corrosion du magnesium et de certains de ses alliages dans les piles refroidies par gaz

    Energy Technology Data Exchange (ETDEWEB)

    Caillat, R.; Darras, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The results of corrosion tests on magnesium and some magnesium alloys (Mg-Zr and Mg-Zr-Zn) in moist air (like G1 reactor) and in CO{sub 2}: (like G2, G3, EDF1 reactors) are reported. The maximum temperature for exposure of magnesium to moist air without any risk of corrosion is 350 deg. C. Indeed, the oxidation rate follows a linear law above 350 deg. C although it reaches a constant level and keeps on very low under 350 deg. C. However, as far as corrosion is concerned this temperature limit can be raised up to 500 deg. C if moist air is very slightly charged with fluorinated compounds. Under pressure of CO{sub 2}, these three materials oxidate much more slowly even if 500 deg. C is reached. The higher is the temperature, the higher is the constant level of the weight increase and the quicker is reached this one. However, Mg-Zr alloy behaves quite better than pure magnesium and especially than Mg-Zr-Zn alloy. (author)Fren. [French] On expose essentiellement les resultats d'etudes sur la corrosion du magnesium et de certains de ses alliages (Mg-Zr et Mg-Zr-Zn) dans l'air humide (cas de la pile G1) et dans le gaz carbonique (cas des piles G2, G3, EDF1, etc...). La temperature limite d'exposition du magnesium dans l'air humide sans risque de corrosion se situe a 350 deg. C; en effet l'oxydation a un caractere lineaire au-dessus de cette temperature, alors qu'elle atteint un palier et reste tres limitee au-dessous de 350 deg. C. Du point de vue de la corrosion, cette temperature limite d'emploi peut cependant etre elevee jusqu'a 500 deg. C si l'on introduit dans l'air humide de tres faibles teneurs de composes fluores. Dans le gaz carbonique sous pression, l'oxydation est beaucoup plus faible, meme jusqu'a 50g. C pour les trois materiaux: l'augmentation de poids atteint un palier d'autant plus eleve et ceci d'autant plus rapidement que la temperature est elle-meme plus elevee. Cependant, l

  16. Single ionization of diatomic molecules by bare ion impact

    International Nuclear Information System (INIS)

    Purkait, M; Mandal, C R

    2014-01-01

    The molecular three-Coulomb wave model (M3CW) has been extensively used to study the double-differential ionization cross sections (DDCS) of diatomic molecules by the impact of bare ions at intermediate and high energies. In this model, the distortion of the initial channel by the incoming projectile is also included. The present DDCS results are found to be in good accord both with the experiment of Baran et al 2008 as well as with other theory

  17. Towards non-sequential double ionization of Ne and Ar using a femtosecond laser oscillator.

    Science.gov (United States)

    Liu, Yunquan; Tschuch, Sebastian; Dürr, Martin; Rudenko, Artem; Moshammer, Robert; Ullrich, Joachim; Siegel, Martin; Morgner, Uwe

    2007-12-24

    We report on first proof-of-principles results on non-sequential double ionization of argon and neon achieved by using a newly developed long-cavity Ti:sapphire femtosecond oscillator with a pulse duration of 45 fs and a repetition of 6.2 MHz combined with a dedicated reaction microscope. Under optimized experimental conditions, peak intensities larger than 2.310(14) W/cm(2) have been achieved. Ion momentum distributions were recorded for both rare gases and show significantly different features for single as well as for double ionization. For single ionization of neon a spike of zero-momentum electrons is found when decreasing the laser intensity towards the lowest ionization rate we can measure which is attributed to a non-resonant ionization channel. As to double ionization, the longitudinal momentum distribution for Ne(2+) displays a clear double-hump structure whereas this feature is found to be smoothened out with a maximum at zero momentum for Ar(2+).

  18. Solid state cathode materials for secondary magnesium-ion batteries that are compatible with magnesium metal anodes in water-free electrolyte

    International Nuclear Information System (INIS)

    Crowe, Adam J.; Bartlett, Bart M.

    2016-01-01

    With high elemental abundance, large volumetric capacity, and dendrite-free metal deposition, magnesium metal anodes offer promise in beyond-lithium-ion batteries. However, the increased charge density associated with the divalent magnesium-ion (Mg 2+ ), relative to lithium-ion (Li + ) hinders the ion-insertion and extraction processes within many materials and structures known for lithium-ion cathodes. As a result, many recent investigations incorporate known amounts of water within the electrolyte to provide temporary solvation of the Mg 2+ , improving diffusion kinetics. Unfortunately with the addition of water, compatibility with magnesium metal anodes disappears due to forming an ion-insulating passivating layer. In this short review, recent advances in solid state cathode materials for rechargeable magnesium-ion batteries are highlighted, with a focus on cathode materials that do not require water contaminated electrolyte solutions for ion insertion and extraction processes. - Graphical abstract: In this short review, we present candidate materials for reversible Mg-battery cathodes that are compatible with magnesium metal in water-free electrolytes. The data suggest that soft, polarizable anions are required for reversible cycling.

  19. Investigation of samarium solubility in the magnesium based solid solution

    International Nuclear Information System (INIS)

    Rokhlin, L.L.; Padezhnova, E.M.; Guzej, L.S.

    1976-01-01

    Electric resistance measurements and microscopic analysis were used to investigate the solubility of samarium in a magnesium-based solid solution. The constitutional diagram Mg-Sm on the magnesium side is of an eutectic type with the temperature of the eutectic transformation of 542 deg C. Samarium is partly soluble in solid magnesium, the less so, the lower is the temperature. The maximum solubility of samarium in magnesium (at the eutectic transformation point) is 5.8 % by mass (0.99 at. %). At 200 deg C, the solubility of samarium in magnesium is 0.4 % by mass (0.063 at. %)

  20. The multiphoton ionization of uranium hexafluoride

    International Nuclear Information System (INIS)

    Armstrong, D.P.

    1992-05-01

    Multiphoton ionization (MPI) time-of-flight mass spectroscopy and photoelectron spectroscopy studies of UF 6 have been conducted using focused light from the Nd:YAG laser fundamental (λ=1064 nm) and its harmonics (λ=532, 355, or 266 nm), as well as other wavelengths provided by a tunable dye laser. The MPI mass spectra are dominated by the singly and multiply charged uranium ions rather than by the UF x + fragment ions even at the lowest laser power densities at which signal could be detected. The laser power dependence of U n+ ions signals indicates that saturation can occur for many of the steps required for their ionization. In general, the doubly-charged uranium ion (U 2+ ) intensity is much greater than that of the singly-charged uranium ion (U + ). For the case of the tunable dye laser experiments, the U n+ (n = 1- 4) wavelength dependence is relatively unstructured and does not show observable resonance enhancement at known atomic uranium excitation wavelengths. The dominance of the U 2+ ion and the absence or very small intensities of UF x + fragments, along with the unsaturated wavelength dependence, indicate that mechanisms may exist other than ionization of bare U atoms after the stepwise photodissociation of F atoms from the parent molecule

  1. Magnesium and related low alloys

    International Nuclear Information System (INIS)

    Bernard, J.; Caillat, R.; Darras, R.

    1959-01-01

    In the first part the authors examine the comparative corrosion of commercial magnesium, of a magnesium-zirconium alloy (0,4 per cent ≤ Zr ≤ 0,7 per cent) of a ternary magnesium-zinc-zirconium alloy (0,8 per cent ≤ Zn ≤ 1,2 per cent) and of english 'Magnox type' alloys, in dry carbon dioxide-free air, in damp carbon dioxide-free air, and in dry and damp carbon dioxide, at temperatures from 300 to 600 deg. C. In the second part the structural stability of these materials is studied after annealings, of 10 to 1000 hours at 300 to 450 deg. C. Variations in grain after these heat treatments and mechanical stretching properties at room temperature are presented. Finally various creep rate and life time diagrams are given for these materials, for temperatures ranging from 300 to 450 deg. C. (author) [fr

  2. Ionization and photofragmentation of Ru3(CO)12 and Os3(CO)12

    International Nuclear Information System (INIS)

    Schalk, Oliver; Josefsson, Ida; Odelius, Michael; Richter, Robert; Prince, Kevin C.; Mucke, Melanie

    2015-01-01

    In this paper, we use a combination of photoelectron spectroscopy, mass spectrometry, and density functional theory calculations to get a detailed understanding of valence single and double ionization and the subsequent dissociation processes. This is exemplified on benchmark systems, trimetallo-dodecacarbonyls M 3 (CO) 12 with M = Ru, Os, where the energy remaining in the molecule after photoionization can be retrieved by measuring the degree of fragmentation of the molecular ion. The intensity of different mass peaks can thus be directly related to ionization cross sections obtained by photoelectron spectroscopy. We find that the M—CO dissociation energy rises as the number of CO ligands decreases due to dissociation. Moreover, ionization of the CO ligands has a higher cross section than that of the metal center for both single and double ionization. After advanced fragmentation, a CO bond can break and the carbon atom remains bonded to the metal core. In addition, we found that the valence ionization cross sections of M 3 (CO) 12 are maximal at about 40 eV photon energy thus showing a more pronounced shape resonance than Ru and Os-complexes with a single metal atom center. Finally, an np → nd giant resonance absorption causes a significant increase of the ionization cross section above 50 eV for Ru 3 (CO) 12

  3. Dependence of the Mg-related acceptor ionization energy with the acceptor concentration in p-type GaN layers grown by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Brochen, Stéphane; Brault, Julien; Chenot, Sébastien; Dussaigne, Amélie; Leroux, Mathieu; Damilano, Benjamin

    2013-01-01

    Hall effect and capacitance-voltage C(V) measurements were performed on p-type GaN:Mg layers grown on GaN templates by molecular beam epitaxy with a high range of Mg-doping concentrations. The free hole density and the effective dopant concentration N A −N D as a function of magnesium incorporation measured by secondary ion mass spectroscopy clearly reveal both a magnesium doping efficiency up to 90% and a strong dependence of the acceptor ionization energy Ea with the acceptor concentration N A . These experimental observations highlight an isolated acceptor binding energy of 245±25 meV compatible, at high acceptor concentration, with the achievement of p-type GaN:Mg layers with a hole concentration at room temperature close to 10 19 cm −3

  4. Femtosecond Light Source for Phase-Controlled Multiphoton Ionization

    International Nuclear Information System (INIS)

    Sokolov, A. V.; Walker, D. R.; Yavuz, D. D.; Yin, G. Y.; Harris, S. E.

    2001-01-01

    We describe a femtosecond Raman light source with more than an octave of optical bandwidth. We use this source to demonstrate phase control of multiphoton ionization under conditions where ionization requires eleven photons of the lowest frequency of the spectrum or five photons of the highest frequency. The nonlinearity of the photoionization process allows us to characterize the light source. Experiment-to-theory comparison implies generation of a near single-cycle waveform

  5. Comparison of Serum Calcium and Magnesium Between ...

    African Journals Online (AJOL)

    Background: Evidence suggests the involvement of calcium and magnesium metabolism in the pathophysiology of preeclampsia. However, findings from studies are heterogenous and inconsistent. Aim: The study aimed to compare the total serum calcium and magnesium levels in preeclamptic women with that of ...

  6. Design of the Intravenous Magnesium Efficacy in Acute Stroke (IMAGES) trial.

    Science.gov (United States)

    Bradford, Andrew; Lees, Kennedy

    2000-01-01

    The Intravenous Magnesium Efficacy in Acute Stroke (IMAGES) trial is a multicentre,randomised, placebo-controlled trial of magnesium sulphate (MgSO4) funded by the UK Medical Research Council. When complete, it will be the largest single neuroprotective study undertaken to date. Conscious patients presenting within 12 h of acute stroke with limb weakness are eligible. The primary outcome measure is combined death and disability as measured using the Barthel Index at 90-day follow up. By randomizing 2700 patients, the study will have 84% power to detect a 5.5% absolute reduction in the primary end-point. By April 2000, 86 centres were participating, with representation in Canada, USA, Europe, South America, Singapore and Australia. So far, 1206 patients have been randomised, of whom 37% were treated within 6 h. Overall 3-month mortality was 20% and the primary outcome event rate was 43%. The study is ongoing and centres worldwide are encouraged to participate.

  7. Single capture and transfer ionization in collisions of Clq+ projectile ions incident on helium

    International Nuclear Information System (INIS)

    Wong, K.L.; Ben-Itzhak, I.; Cocke, C.L.; Giese, J.P.; Richard, P.

    1995-01-01

    The Kansas State University linac has been used to measure the ratio of the cross sections for the processes of transfer ionization (TI) and single capture (SC) for 2 MeV/amu Cl q+ where q=7, 9, 13, 14, and 15 projectile ions incident on a helium target. The ratio was determined using a helium gas jet target by measuring coincidences between projectile-ion and recoil-ion final charge states. The σ TI /σ SC for Cl q+ were compared to measurements of bare F 9+ and hydrogenlike F 8+ and O 7+ taken at the same velocity. The ratios deviate from a q 2 scaling which is predicted in the perturbative regime. This deviation is attributed to screening by the projectile electrons for low q=7 and 9, and to the collision being non-perturbative for high q. A possible saturation effect in the ratio was observed for q similar 14. (orig.)

  8. Multiple ionization of C{sub 60} in collisions with 2.33MeV/u O-ions and giant plasmon excitation

    Energy Technology Data Exchange (ETDEWEB)

    Kelkar, A.H. [Tata Institute of Fundamental Research, Colaba, Mumbai 400 005 (India)]. E-mail: lokesh@tifr.res.in; Kadhane, U. [Tata Institute of Fundamental Research, Colaba, Mumbai 400 005 (India); Misra, D. [Tata Institute of Fundamental Research, Colaba, Mumbai 400 005 (India); Kumar, Ajay [Tata Institute of Fundamental Research, Colaba, Mumbai 400 005 (India); Tribedi, L.C. [Tata Institute of Fundamental Research, Colaba, Mumbai 400 005 (India)

    2007-03-15

    Single and multiple ionization of C{sub 60} in collisions with fast (v=9.7a.u.) O{sup q+} ions have been studied. Relative cross sections for production of C{sub 60}{sup 1+} to C{sub 60}{sup 4+} have been measured. The intensity ratios of double-to-single ionization agree very well with a model based on giant dipole plasmon resonance (GDPR). Almost linear increasing trend of the yields of single and double ionizations with projectile charge state is well reproduced by the single and double plasmon excitation mechanisms. The observed charge state independence of triple and quadruple ionization is in sharp contrast to the GDPR model.

  9. Justification for intravenous magnesium therapy in acute myocardial infarction

    DEFF Research Database (Denmark)

    Rasmussen, H S

    1988-01-01

    Recent studies have shown that patients with acute myocardial infarction (AMI) are magnesium-deficient and develop an additional transient decrease in serum magnesium concentrations (S-Mg c) during the acute phase of the infarct. Animal experiments, as well as studies on humans, have indicated.......v. magnesium therapy on mortality and incidence of arrhythmias in patients with AMI has been evaluated. Magnesium treatment more than halved the acute mortality and incidence of arrhythmias requiring treatment in three of the four intervention studies. The mechanisms behind the beneficial effect of magnesium...... therapy are probably multifactorial; a direct depressive effect on the cardiac conducting system; a peripheral dilatory effect on the arteries, reducing the afterload on the myocardium; a reduced infarct size; an ion-stabilizing effect, maintaining stable intra and extracellular concentrations...

  10. Magnesium Borate Synthesis by Microwave Energy: A New Method

    Directory of Open Access Journals (Sweden)

    Azmi Seyhun Kipcak

    2013-01-01

    Full Text Available Magnesium borates are one of the major groups of boron minerals that have important properties such as high heat and corrosion resistances and high coefficients of elasticity. In this study, magnesium borate minerals are synthesized using boric acid and magnesium oxide with a new method of microwave, and the synthesized minerals are characterized by various analysis techniques. The results show that pure, “magnesium borate hydrate” minerals are obtained at the end of various steps. The characterization of the products is determined with the techniques of X-Ray Diffraction (XRD, Fourier Transform Infrared Spectroscopy (FT-IR, Raman Spectroscopy, and Scanning Electron Microscopy (SEM. Additionally, overall “magnesium borate hydrate” yields are calculated and found about 67% at 270 W, 8 minutes and 360 W, 3 minutes of reaction times, respectively.

  11. Magnesium in diet

    Science.gov (United States)

    ... sources of magnesium: Fruits or vegetables (such as bananas, dried apricots, and avocados) Nuts (such as almonds ... deficiency: Low blood calcium level (hypocalcemia) Low blood potassium level (hypokalemia) Recommendations These are the recommended daily ...

  12. Is serum magnesium estimate necessary in patients with Eclampsia ...

    African Journals Online (AJOL)

    The therapeutic index of magnesium is said to be low, hence, there are fears of toxicity when used as anticonvulsant in eclamptic patients. The objective of this study was to determine the serum levels of magnesium in eclamptic patients treated with magnesium sulphate and relate the levels with clinical indicators. It was a ...

  13. Magnesium removal in the electrolytic zinc industry

    NARCIS (Netherlands)

    Booster, J.L.

    2003-01-01

    Electrolytic zinc plants need to take measures to control the magnesium content in their process liquors, because the natural magnesium bleed does not balance the input from concentrates. Presently used methods are environmentally unfriendly (due to the production of large amounts of waste gypsum)

  14. Machinability of magnesium and aluminium alloys. Part I: cutting resistance

    International Nuclear Information System (INIS)

    Balout, B.; Songmene, V.; Masounave, J.

    2002-01-01

    Aluminium (2.7 g/cm 3 ) and magnesium (1.7 g/cm 3 ) are two competing light metals with similar mechanical properties and excellent possibilities for recycling. The forming of magnesium is often seen as an impediment to its use. New forming techniques using magnesium shavings are being developed, particularly in Japan. The machining of magnesium alloys by removal of metal raises safety concerns (risk of fire), which limits many potential applications of magnesium. The purpose of this work is to clarify and compare the machining properties of these two types of metal and better understand the mechanisms that may explain the differences in behaviour. Such a comparison could eventually provide an estimate of the cost of producing shavings for the manufacture of aluminium and magnesium parts through forging and extrusion, which would limit environmental pollution. Based on an analysis of cutting resistance during machining, it was demonstrated that magnesium alloys are easier to machine than similar aluminium alloys. Magnesium shavings are shorter than those of 6061-T6, but are especially more regular than those of A356, and their size is independent of cutting speed. It was also demonstrated that the fragility of materials can be characterized based on the results of cutting resistance produced during drilling

  15. Magnesium and manganese content of halophilic bacteria

    International Nuclear Information System (INIS)

    de Medicis, E.; Paquette, J.; Gauthier, J.J.; Shapcott, D.

    1986-01-01

    Magnesium and manganese contents were measured by atomic absorption spectrophotometry in bacteria of several halophilic levels, in Vibrio costicola, a moderately halophilic eubacterium growing in 1 M NaCl, Halobacterium volcanii, a halophilic archaebacterium growing in 2.5 NaCl, Halobacterium cutirubrum, an extremely halophilic archaebacterium growing in 4 M NaCl, and Escherichia coli, a nonhalophilic eubacterium growing in 0.17 M NaCl. Magnesium and manganese contents varied with the growth phase, being maximal at the early log phase. Magnesium and manganese molalities in cell water were shown to increase with the halophilic character of the logarithmically growing bacteria, from 30 mmol of Mg per kg of cell water and 0.37 mmol of Mn per kg of cell water for E. coli to 102 mmol of Mg per kg of cell water and 1.6 mmol of Mn per kg of cell water for H cutirubrum. The intracellular concentrations of manganese were determined independently by a radioactive tracer technique in V. costicola and H. volcanii. The values obtained by 54 Mn loading represented about 70% of the values obtained by atomic absorption. The increase of magnesium and manganese contents associated with the halophilic character of the bacteria suggests that manganese and magnesium play a role in haloadaptation

  16. Effects of extracellular magnesium on the differentiation and function of human osteoclasts.

    Science.gov (United States)

    Wu, Lili; Luthringer, Bérengère J C; Feyerabend, Frank; Schilling, Arndt F; Willumeit, Regine

    2014-06-01

    Magnesium-based implants have been shown to influence the surrounding bone structure. In an attempt to partially reveal the cellular mechanisms involved in the remodelling of magnesium-based implants, the influence of increased extracellular magnesium content on human osteoclasts was studied. Peripheral blood mononuclear cells were driven towards an osteoclastogenesis pathway via stimulation with receptor activator of nuclear factor kappa-B ligand and macrophage colony-stimulating factor for 28 days. Concomitantly, the cultures were exposed to variable magnesium concentrations (from either magnesium chloride or magnesium extracts). Osteoclast proliferation and differentiation were evaluated based on cell metabolic activity, total protein content, tartrate-resistant acid phosphatase activity, cathepsin K and calcitonin receptor immunocytochemistry, and cellular ability to form resorption pits. While magnesium chloride first enhanced and then opposed cell proliferation and differentiation in a concentration-dependent manner (peaking between 10 and 15mM magnesium chloride), magnesium extracts (with lower magnesium contents) appeared to decrease cell metabolic activity (≈50% decrease at day 28) while increasing osteoclast activity at a lower concentration (twofold higher). Together, the results indicated that (i) variations in the in vitro extracellular magnesium concentration affect osteoclast metabolism and (ii) magnesium extracts should be used preferentially in vitro to more closely mimic the in vivo environment. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  17. Magnesium borate radiothermoluminescent detectors

    International Nuclear Information System (INIS)

    Kazanskaya, V.A.; Kuzmin, V.V.; Minaeva, E.E.; Sokolov, A.D.

    1974-01-01

    In the report the technology of obtaining polycrystalline magnesium borate activated by dysprosium is described briefly and the method of preparing the tabletted detectors from it is presented. The dependence of the light sum of the samples on the proportion of the components and on the sintering regime has shown that the most sensitive material is obtained at the proportion of boric anhydride and magnesium oxide 2.2-2.4 and at the dysprosium concentration about 1 milligram-atom per gram molecule of the base. The glow curve of such a material has a simple form with one peak the maximum of which is located at 190-200 0 C. The measurement of the main dosimetric characteristics of the magnesium borate tabletted detectors and the comparison with similar parmaeters of the lithium fluoride tabletted detectors have shown that at practically identical effective number the former detectors have the following substantial advantages: the sensitivity is ten-twenty times as large, they are substantially more technological on synthesis of the radiothermoluminophor and during the production of the tabletted detectors, they have a simple glow curve, they do not require the utilization of the thermocycling during the use. (author)

  18. Fatigue Analysis of Magnesium Alloys Components for Car Industry

    Science.gov (United States)

    Marsavina, Liviu; Rusu, Lucian; Șerban, Dan Andrei; Negru, Radu Marcel; Cernescu, Anghel

    2017-12-01

    The use of magnesium alloys in the automotive industry increased in the last decade because of their low weight and relative good mechanical properties. However, the variable loading conditions require a good fatigue behavior. This paper summaries the fatigue properties of magnesium alloys and presents new fatigue curve results for die cast AM50 magnesium alloy.

  19. Many-electron model for multiple ionization in atomic collisions

    International Nuclear Information System (INIS)

    Archubi, C D; Montanari, C C; Miraglia, J E

    2007-01-01

    We have developed a many-electron model for multiple ionization of heavy atoms bombarded by bare ions. It is based on the transport equation for an ion in an inhomogeneous electronic density. Ionization probabilities are obtained by employing the shell-to-shell local plasma approximation with the Levine and Louie dielectric function to take into account the binding energy of each shell. Post-collisional contributions due to Auger-like processes are taken into account by employing recent photoemission data. Results for single-to-quadruple ionization of Ne, Ar, Kr and Xe by protons are presented showing a very good agreement with experimental data

  20. Many-electron model for multiple ionization in atomic collisions

    Energy Technology Data Exchange (ETDEWEB)

    Archubi, C D [Instituto de AstronomIa y Fisica del Espacio, Casilla de Correo 67, Sucursal 28 (C1428EGA) Buenos Aires (Argentina); Montanari, C C [Instituto de AstronomIa y Fisica del Espacio, Casilla de Correo 67, Sucursal 28 (C1428EGA) Buenos Aires (Argentina); Miraglia, J E [Instituto de AstronomIa y Fisica del Espacio, Casilla de Correo 67, Sucursal 28 (C1428EGA) Buenos Aires (Argentina)

    2007-03-14

    We have developed a many-electron model for multiple ionization of heavy atoms bombarded by bare ions. It is based on the transport equation for an ion in an inhomogeneous electronic density. Ionization probabilities are obtained by employing the shell-to-shell local plasma approximation with the Levine and Louie dielectric function to take into account the binding energy of each shell. Post-collisional contributions due to Auger-like processes are taken into account by employing recent photoemission data. Results for single-to-quadruple ionization of Ne, Ar, Kr and Xe by protons are presented showing a very good agreement with experimental data.

  1. The multiple ionization of helium induced by partially stripped carbon ions

    International Nuclear Information System (INIS)

    Cai Xiaohong; Chen Ximeng; Shen Ziyong

    1996-01-01

    The ratios of the double to single ionization cross sections of helium impacted by partially stripped C q+ ions (q = 1,2,3,4) in energy range of 1.5-7.5 MeV were measured by using the time of flight procedure. The n-body classical trajectory Monte Carlo calculation was carried out to get the Olson-Schlachter scaling. The single and double ionization cross sections of helium were obtained by comparing the cross section ratios of the present work with the Olson-Schlachter scaling

  2. Unphysiologically high magnesium concentrations support chondrocyte proliferation and redifferentiation.

    Science.gov (United States)

    Feyerabend, Frank; Witte, Frank; Kammal, Michael; Willumeit, Regine

    2006-12-01

    The effect of unphysiologically high extracellular magnesium concentrations on chondrocytes, induced by the supplementation of magnesium sulfate, was studied using a 3-phase tissue engineering model. The experiments showed that chondrocyte proliferation and redifferentiation, on the gene and protein expression level, are enhanced. A negative influence was found during chondrogenesis where an inhibition of extracellular matrix formation was observed. In addition, a direct impact on chondrocyte metabolism, elevated magnesium concentrations also affected growth factor effectiveness by consecutive influences during chondrogenesis. All observations were dosage dependent. The results of this study indicate that magnesium may be a useful tool for cartilage tissue engineering.

  3. Magnesium supplementation in children with attention deficit ...

    African Journals Online (AJOL)

    Background: Attention deficit hyperactivity disorder (ADHD) is a common neurodevelopmental disorder with associated mineral deficiency. Aim: To assess magnesium level in ADHD children and compare it to the normal levels in children. Then, to detect the effect of magnesium supplementation as an add on therapy, ...

  4. Design Considerations for Developing Biodegradable Magnesium Implants

    Science.gov (United States)

    Brar, Harpreet S.; Keselowsky, Benjamin G.; Sarntinoranont, Malisa; Manuel, Michele V.

    The integration of biodegradable and bioabsorbable magnesium implants into the human body is a complex undertaking that faces major challenges. The complexity arises from the fact that biomaterials must meet both engineering and physiological requirements to ensure the desired properties. Historically, efforts have been focused on the behavior of commercial magnesium alloys in biological environments and their resultant effect on cell-mediated processes. Developing causal relationships between alloy chemistry and micro structure, and its effect on cellular behavior can be a difficult and time intensive process. A systems design approach driven by thermodynamics has the power to provide significant contributions in developing the next generation of magnesium alloy implants with controlled degradability, biocompatibility, and optimized mechanical properties, at reduced time and cost. This approach couples experimental research with theory and mechanistic modeling for the accelerated development of materials. The aim of this article is to enumerate this strategy, design considerations and hurdles for developing new magnesium alloys for use as biodegradable implant materials [1].

  5. Biodegradable magnesium nanoparticle-enhanced laser hyperthermia therapy

    Directory of Open Access Journals (Sweden)

    Wang Q

    2012-08-01

    Full Text Available Qian Wang,1 Liping Xie,1 Zhizhu He,2 Derui Di,2 Jing Liu1,21Department of Biomedical Engineering, School of Medicine, Tsinghua University, 2Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, People's Republic of ChinaBackground: Recently, nanoparticles have been demonstrated to have tremendous merit in terms of improving the treatment specificity and thermal ablation effect on tumors. However, the potential toxicity and long-term side effects caused by the introduced nanoparticles and by expelling them out of the body following surgery remain a significant challenge. Here, we propose for the first time to directly adopt magnesium nanoparticles as the heating enhancer in laser thermal ablation to avoid these problems by making full use of the perfect biodegradable properties of this specific material.Methods: To better understand the new nano “green” hyperthermia modality, we evaluated the effects of magnesium nanoparticles on the temperature transients inside the human body subject to laser interstitial heating. Further, we experimentally investigated the heating enhancement effects of magnesium nanoparticles on a group of biological samples: oil, egg white, egg yolk, in vitro pig tissues, and the in vivo hind leg of rabbit when subjected to laser irradiation.Results: Both the theoretical simulations and experimental measurements demonstrated that the target tissues injected with magnesium nanoparticles reached much higher temperatures than tissues without magnesium nanoparticles. This revealed the enhancing behavior of the new nanohyperthermia method.Conclusion: Given the unique features of magnesium nanoparticles – their complete biological safety and ability to enhance heating – which most other advanced metal nanoparticles do not possess, the use of magnesium nanoparticles in hyperthermia therapy offers an important “green” nanomedicine modality for treating tumors

  6. Magnesium Counteracts Vascular Calcification: Passive Interference or Active Modulation?

    Science.gov (United States)

    Ter Braake, Anique D; Shanahan, Catherine M; de Baaij, Jeroen H F

    2017-08-01

    Over the last decade, an increasing number of studies report a close relationship between serum magnesium concentration and cardiovascular disease risk in the general population. In end-stage renal disease, an association was found between serum magnesium and survival. Hypomagnesemia was identified as a strong predictor for cardiovascular disease in these patients. A substantial body of in vitro and in vivo studies has identified a protective role for magnesium in vascular calcification. However, the precise mechanisms and its contribution to cardiovascular protection remain unclear. There are currently 2 leading hypotheses: first, magnesium may bind phosphate and delay calcium phosphate crystal growth in the circulation, thereby passively interfering with calcium phosphate deposition in the vessel wall. Second, magnesium may regulate vascular smooth muscle cell transdifferentiation toward an osteogenic phenotype by active cellular modulation of factors associated with calcification. Here, the data supporting these major hypotheses are reviewed. The literature supports both a passive inorganic phosphate-buffering role reducing hydroxyapatite formation and an active cell-mediated role, directly targeting vascular smooth muscle transdifferentiation. However, current evidence relies on basic experimental designs that are often insufficient to delineate the underlying mechanisms. The field requires more advanced experimental design, including determination of intracellular magnesium concentrations and the identification of the molecular players that regulate magnesium concentrations in vascular smooth muscle cells. © 2017 American Heart Association, Inc.

  7. X-linked immunodeficiency with magnesium defect, Epstein-Barr virus infection, and neoplasia disease: a combined immune deficiency with magnesium defect.

    Science.gov (United States)

    Ravell, Juan; Chaigne-Delalande, Benjamin; Lenardo, Michael

    2014-12-01

    To describe the role of the magnesium transporter 1 (MAGT1) in the pathogenesis of 'X-linked immunodeficiency with magnesium defect, Epstein-Barr virus (EBV) infection, and neoplasia' (XMEN) disease and its clinical implications. The magnesium transporter protein MAGT1 participates in the intracellular magnesium ion (Mg) homeostasis and facilitates a transient Mg influx induced by the activation of the T-cell receptor. Loss-of-function mutations in MAGT1 cause an immunodeficiency named 'XMEN syndrome', characterized by CD4 lymphopenia, chronic EBV infection, and EBV-related lymphoproliferative disorders. Patients with XMEN disease have impaired T-cell activation and decreased cytolytic function of natural killer (NK) and CD8 T cells because of decreased expression of the NK stimulatory receptor 'natural-killer group 2, member D' (NKG2D). Patients may have defective specific antibody responses secondary to T cell dysfunction, but B cells have not been shown to be directly affected by mutations in MAGT1. XMEN disease has revealed a novel role for free intracellular magnesium in the immune system. Further understanding of the MAGT1 signaling pathway may lead to new diagnostic and therapeutic approaches.

  8. Serum magnesium and the risk of prediabetes: a population-based cohort study.

    Science.gov (United States)

    Kieboom, Brenda C T; Ligthart, Symen; Dehghan, Abbas; Kurstjens, Steef; de Baaij, Jeroen H F; Franco, Oscar H; Hofman, Albert; Zietse, Robert; Stricker, Bruno H; Hoorn, Ewout J

    2017-05-01

    Previous studies have found an association between serum magnesium and incident diabetes; however, this association may be due to reverse causation, whereby diabetes may induce urinary magnesium loss. In contrast, in prediabetes (defined as impaired fasting glucose), serum glucose levels are below the threshold for urinary magnesium wasting and, hence, unlikely to influence serum magnesium levels. Thus, to study the directionality of the association between serum magnesium levels and diabetes, we investigated its association with prediabetes. We also investigated whether magnesium-regulating genes influence diabetes risk through serum magnesium levels. Additionally, we quantified the effect of insulin resistance in the association between serum magnesium levels and diabetes risk. Within the population-based Rotterdam Study, we used Cox models, adjusted for age, sex, lifestyle factors, comorbidities, kidney function, serum levels of electrolytes and diuretic use, to study the association between serum magnesium and prediabetes/diabetes. In addition, we performed two mediation analyses: (1) to study if common genetic variation in eight magnesium-regulating genes influence diabetes risk through serum magnesium levels; and (2) to quantify the proportion of the effect of serum magnesium levels on diabetes that is mediated through insulin resistance (quantified by HOMA-IR). A total of 8555 participants (mean age, 64.7 years; median follow-up, 5.7 years) with normal glucose levels (mean ± SD: 5.46 ± 0.58 mmol/l) at baseline were included. A 0.1 mmol/l decrease in serum magnesium level was associated with an increase in diabetes risk (HR 1.18 [95% CI 1.04, 1.33]), confirming findings from previous studies. Of interest, a similar association was found between serum magnesium levels and prediabetes risk (HR 1.12 [95% CI 1.01, 1.25]). Genetic variation in CLDN19, CNNM2, FXYD2, SLC41A2, and TRPM6 significantly influenced diabetes risk (p prediabetes 13.4% was

  9. Ionizing Shocks in Argon. Part 2: Transient and Multi-Dimensional Effects (Preprint)

    Science.gov (United States)

    2010-09-09

    stability in ionizing monatomic gases. Part 1. Argon ,” J. Fluid Mech., 84, 55 (1978). 2M. P. F. Bristow and I. I. Glass, “ Polarizability of singly...Article 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Ionizing Shocks in Argon . Part 2: Transient...Physics. 14. ABSTRACT We extend the computations of ionizing shocks in argon to unsteady and multi-dimensional, using a collisional-radiative

  10. Casting Porosity-Free Grain Refined Magnesium Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Schwam, David [Case Western Reserve University

    2013-08-12

    The objective of this project was to identify the root causes for micro-porosity in magnesium alloy castings and recommend remedies that can be implemented in production. The findings confirm the key role played by utilizing optimal gating and risering practices in minimizing porosity in magnesium castings. 

  11. Biodegradable magnesium-alloy stent:current situation in research

    International Nuclear Information System (INIS)

    Chen Hua; Zhao Xianxian

    2011-01-01

    In recent years, permanent metal stents are employed in the majority of interventional therapies; nevertheless, such kind of stents carries the problems of thrombosis and restenosis. Therefore, the biodegradable magnesium alloy stent has become the focus of attention. Theoretically, it has overcome the problems caused by permanent metal stents, so it is the development direction to use the biodegradable magnesium alloy in future. The authors believe that biodegradable magnesium alloy stents will be widely used in interventional procedures for many diseases. (authors)

  12. Lithium/magnesium oxide catalyst and method of making

    Energy Technology Data Exchange (ETDEWEB)

    Lunsford, J.H.; Hinson, P.G.

    1991-07-16

    This patent describes a method for preparing a catalyst which is effective for converting methane to ethane and ethylene. It comprises mixing a solution of a magnesium alkoxide in an alcohol with a solution containing a source of lithium in an alcohol, to obtain a ratio of magnesium metal to lithium metal; hydrolyzing the magnesium alkoxide in the solution to form a gel; and calcining the gel to form a catalyst which is effective for converting methane to ethane and ethylene.

  13. Cytotoxic effect of galvanically coupled magnesium-titanium particles.

    Science.gov (United States)

    Kim, Jua; Gilbert, Jeremy L

    2016-01-01

    Recent work has shown that reduction reactions at metallic biomaterial surfaces can induce significant killing of cells in proximity to the surface. To exploit this phenomenon for therapeutic purposes, for example, for cancer tumor killing or antibacterial effects (amongst other applications), magnesium metal particles, galvanically coupled to titanium by sputtering, have been evaluated for their cell-killing capability (i.e. cytotoxicity). Magnesium (Mg) particles large enough to prevent particle phagocytosis were investigated, so that only electrochemical reactions, and not particle toxicity per se, caused cytotoxic effects. Titanium (Ti) coated magnesium particles, as well as magnesium-only particles were introduced into MC3T3-E1 mouse pre-osteoblast cell cultures over a range of particle concentrations, and cells were observed to die in a dosage-dependent manner. Ti-coated magnesium particles killed more cells at lower particle concentration than magnesium alone (Pmagnesium and magnesium-titanium had no significant difference at similar particle concentrations. Complete cell killing occurred at 750μg/ml and 1500μg/ml for Mg-Ti and Mg, respectively. Thus, this work demonstrates that galvanically coupled Mg-Ti particles have a significant cell killing capability greater than Mg alone. In addition, when the pH associated with complete killing with particles was created using NaOH only (no particles), then the percentage of cells killed was significantly less (Pmagnesium-titanium microparticles kill cells more effectively than magnesium particles alone. The killing effect was shown to not be due to pH shifts since no differences were seen for different particle types and pH adjusted medium without particles did not exhibit the same level of killing. The significance of this work is the recognition of this killing effect with Mg particles and the potential therapeutic applications in infection control and cancer treatment that this process may provide. Copyright

  14. Impurity characterization of magnesium diuranate using simultaneous TG–DTA–FTIR measurements

    Energy Technology Data Exchange (ETDEWEB)

    Raje, Naina, E-mail: nraje@barc.gov.in [Analytical Chemistry Division, B.A.R.C., Mumbai 400 085 (India); Ghonge, Darshana K. [Analytical Chemistry Division, B.A.R.C., Mumbai 400 085 (India); Hemantha Rao, G.V.S. [NFC, ECIL Post, Hyderabad (India); Reddy, A.V.R. [Analytical Chemistry Division, B.A.R.C., Mumbai 400 085 (India)

    2013-05-15

    Current studies describe the application of simultaneous thermogravimetry–differential thermal analysis – evolved gas analysis techniques for the compositional characterization of magnesium diuranate (MDU) with respect to the impurities present in the matrix. The stoichiometric composition of MDU was identified as MgU{sub 2}O{sub 7}⋅3H{sub 2}O. Presence of carbonate and sulphate as impurities in the matrix was confirmed through the evolved gas analysis using Fourier Transformation Infrared Spectrometry detection. Carbon and magnesium hydroxide content present as impurities in magnesium diuranate have been determined quantitatively using TG and FTIR techniques and the results are in good agreement. Powder X-ray diffraction analysis of magnesium diuranate suggests the presence of magnesium hydroxide as impurity in the matrix. Also these studies confirm the formation of magnesium uranate, uranium sesquioxide and uranium dioxide above 1000 °C, due to the decomposition of magnesium diuranate.

  15. Multivariate regression models for the simultaneous quantitative analysis of calcium and magnesium carbonates and magnesium oxide through drifts data

    Directory of Open Access Journals (Sweden)

    Marder Luciano

    2006-01-01

    Full Text Available In the present work multivariate regression models were developed for the quantitative analysis of ternary systems using Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS to determine the concentration in weight of calcium carbonate, magnesium carbonate and magnesium oxide. Nineteen spectra of standard samples previously defined in ternary diagram by mixture design were prepared and mid-infrared diffuse reflectance spectra were recorded. The partial least squares (PLS regression method was applied to the model. The spectra set was preprocessed by either mean-centered and variance-scaled (model 2 or mean-centered only (model 1. The results based on the prediction performance of the external validation set expressed by RMSEP (root mean square error of prediction demonstrated that it is possible to develop good models to simultaneously determine calcium carbonate, magnesium carbonate and magnesium oxide content in powdered samples that can be used in the study of the thermal decomposition of dolomite rocks.

  16. Preparation of plate-shape nano-magnesium hydroxide from asbestos tailings

    International Nuclear Information System (INIS)

    Du Gaoxiang; Zheng Shuilin

    2009-01-01

    To prepare magnesium hydroxide is one of the effective methods to the comprehensive utilization of asbestos tailings. Nano-scale magnesium hydroxide was prepared and mechanisms of in-situ surface modification were characterized in the paper. Process conditions of preparation of magnesium hydroxide from purified hydrochloric acid leachate of asbestos tailings were optimized and in-situ surface modification of the product was carried out. Results showed that optimum process conditions for preparing nano-scale magnesium hydroxide were as follows: initial concentration of Mg 2+ in the leachate was 22.75g/L, precipitant was NaOH solution (mass concentration 20%), reaction temperature was 50 deg. C, and reaction time was 5min. The diameter and thickness of the plate nano-scale magnesium hydroxide powder prepared under optimal conditions were about 100 nm and 10 nm, respectively. However, particle agglomeration was obvious, the particle size increased to micron-grade. Dispersity of the magnesium hydroxide powder could be elevated by in-situ modification by silane FR-693, titanate YB-502 and polyethylene glycol and optimum dosages were 1.5%, 1.5% and 0.75% of the mass of magnesium hydroxide, respectively. All of the modifiers adsorbed chemically on surfaces of magnesium hydroxide particles, among which Si-O-Mg bonds formed among silane FR-693 and the particle surfaces and Ti-O-Mg among titanate YB-502 and the surfaces.

  17. Mercury's complex exosphere: results from MESSENGER's third flyby.

    Science.gov (United States)

    Vervack, Ronald J; McClintock, William E; Killen, Rosemary M; Sprague, Ann L; Anderson, Brian J; Burger, Matthew H; Bradley, E Todd; Mouawad, Nelly; Solomon, Sean C; Izenberg, Noam R

    2010-08-06

    During MESSENGER's third flyby of Mercury, the Mercury Atmospheric and Surface Composition Spectrometer detected emission from ionized calcium concentrated 1 to 2 Mercury radii tailward of the planet. This measurement provides evidence for tailward magnetospheric convection of photoions produced inside the magnetosphere. Observations of neutral sodium, calcium, and magnesium above the planet's north and south poles reveal altitude distributions that are distinct for each species. A two-component sodium distribution and markedly different magnesium distributions above the two poles are direct indications that multiple processes control the distribution of even single species in Mercury's exosphere.

  18. Mercury's Complex Exosphere: Results from MESSENGER's Third Flyby

    Science.gov (United States)

    Vervack, Ronald J., Jr.; McClintock, William E.; Killen, Rosemary M.; Sprague, Ann L.; Anderson, Brian J.; Burger, Matthew H.; Bradley, E. Todd; Mouawad, Nelly; Solomon, Sean C.; Izenberg, Noam R.

    2010-01-01

    During MESSENGER's third flyby of Mercury, the Mercury Atmospheric and Surface Composition Spectrometer detected emission from ionized calcium concentrated 1 to 2 Mercury radii tailward of the planet. This measurement provides evidence for tailward magnetospheric convection of photoions produced inside the magnetosphere. Observations of neutral sodium, calcium, and magnesium above the planet's north and south poles reveal attitude distributions that are distinct for each species. A two-component sodium distribution and markedly different magnesium distributions above the two poles are direct indications that multiple processes control the distribution of even single species in Mercury's exosphere,

  19. Separation of radionuclides from water by magnesium oxide adsorption

    International Nuclear Information System (INIS)

    Tseng, Chia-Lian; Lo, Jem-Mau; Yeh, Si-Jung

    1987-01-01

    Adsorption by magnesium oxide of more than forty radionuclides in respective ionic species in water was observed. Generally, the radionuclides in di-valent and/or multi-valent cations are favorably adsorbed by magnesium oxide; but not for the those in mono-valent cations. In addition, the adsorption by magnesium oxide was not effective to most of the radionuclides in negative ionic species. From the observations, the adsorption mechanism is more prominently by the ion exchange of the di- or multi-valent cation species with the hydrous magnesium oxide. Separation of the radionuclides related to the corrosion products possibly produced in a nuclear power plant from natural seawater was attempted by the magnesium oxide adsorption method. It should be emphasized that the adsorption method was found to be practical for separating radionuclides from a large quantity of natural seawater with high recovery and high reproducibility. (author)

  20. [SIGNIFICANCE OF MAGNESIUM IN PHISIOLOGY AND PATHOLOGY OF THE DIGESTIVE SYSTEM].

    Science.gov (United States)

    Grigus, Ya I; Mikhaylova, O D; Gorbunov A Yu; Vakhrushev, Ya M

    2015-01-01

    The article describes the physiological role of magnesium in the human body and its importance for metabolic processes. The reasons for the development of magnesium deficiency and hypermagnesaemia and its clinical symptoms are shown. The specialties of magnesium metabolism disturbances in gastroenterological pathology are described. Particular attention paid to the correction of magnesium levels with deviations of its content in the organism.

  1. The prospects of biodegradable magnesium-based alloys in osteosynthesis

    Directory of Open Access Journals (Sweden)

    V. N. Chorny

    2013-12-01

    Full Text Available In the analytical review of the literature the main stages of development of biodegradable magnesium alloys in surgery and traumatology were discussed. The analysis revealed the main problems: there is no way to control the speed of the biological resorption alloys, the effects of products of magnesium degradation on the tissues and the organism in general are not studied, there is no information on the characteristics of the regeneration of bone tissue when implanted magnesium implanted magnesium alloys Materials for osteosynthesis with metal clamps made of steel X18H9T are used in 25,0-52,2% of cases, the corrosion of fasteners reaches 18-21%. Corrosion of the metal clips leads to the increase of the concentration of iron, chromium, nickel and titanium in the surrounding tissue. Electrochemical processes in metallic implants occurs due to their structural and chemical inhomogeneous. The microstructure of stainless steel is presented by differently oriented grains. Therefore, the question remains relevant to finding biodegradable materials suitable for implants for osteosynthesis, which could be completely metabolized by the organism, without causing of the pathological effects on the surrounding tissue and the body. The property of magnesium metal dissolved in the tissues of a living organism is known since the 19th century. Payr suggested the use of magnesium metal needles for the treatment of angiomas, in order to achieve thrombosis surrounding the tumor. In 1937 Lambotte made a post in the French Surgical Academy on the application of the osteosynthesis of the shin bone clamps with alloy Dow-metal (magnesium - 92% Aluminum - 8% + traces of manganese, made in the form of loops and screws. In 1938, Earl D. Mc.Braid and published their positive experience with plates and screws made of material similar in composition to the Dow-metal for osteosynthesis of fractures of the arm and forearm bones. Magnesium alloys may be used as a material for

  2. Relationship of serum magnesium level and supplemental magnesium dosage with post coronary artery bypass graft surgery arrhythmias

    Directory of Open Access Journals (Sweden)

    Najafi M

    2007-06-01

    Full Text Available Background: Atrial and ventricular arrhythmias are among the most common complications after coronary artery bypass graft (CABG surgery. Previous studies demonstrated that cardiopulmonary bypass itself results in reduced serum magnesium levels. In this study, we evaluated the effect of total blood magnesium level (TMG on the prevention of perioperative arrhythmias with routine regimens of 2-4 grams supplemental magnesium (SMG. Methods: TMG was measured in patients who were scheduled for CABG on three occasions: just before anesthesia, just after entering the intensive care unit (ICU after completion of the sugery, and on the first morning after the operation. Patients were evaluated for primary cardiac rhythm and other variables that could have an influence on the magnesium level, including serum creatinine, urine output in the operating room and diuretic therapy. The SMG dosage was also recorded in the operating room and ICU. Patients were then evaluated for the rate and type of arrhythmia for the next three days. Results: The mean TMG levels in 174 cases were 2.2 (0.5, 2.6 (0.6 and 2.4 (0.6 mg/dl for the three occasions, respectively. The mean SMG was 2.5 (1.2 grams. Of 164 patients, 51 (31% developed the following post-operative arrhythmias: AF (7.3%, non-AF SVA (15.2% and ventricular (16.5%. The mean serum creatinine level and urine output were 1.2 mg/dl and 1800 ml, respectively. Although there was a significant difference between the TMG levels on the three different occasions (P<0.001, all values were within normal range. When we stratified the TMG levels of the patients based on administered SMG, the Mentel-Haenszel test revealed no significant difference between the first and third TMG (P=0.6. Although the TMG levels were higher in arrhythmic patients compared to those without arrhythmia (2.25 vs. 2.14 mg/dl, both values were within the normal range and there was no significant difference between the two groups. Serum creatinine levels

  3. Thermionic vacuum arc (TVA) technique for magnesium thin film deposition

    Energy Technology Data Exchange (ETDEWEB)

    Balbag, M.Z., E-mail: zbalbag@ogu.edu.t [Eskisehir Osmangazi University, Education Faculty, Primary Education, Meselik Campus, Eskisehir 26480 (Turkey); Pat, S.; Ozkan, M.; Ekem, N. [Eskisehir Osmangazi University, Art and Science Faculty, Physics Department, Eskisehir 26480 (Turkey); Musa, G. [Ovidius University, Physics Department, Constanta (Romania)

    2010-08-15

    In this study, magnesium thin films were deposited on glass substrate by the Thermionic Vacuum Arc (TVA) technique for the first time. We present a different technique for deposition of high-quality magnesium thin films. By means of this technique, the production of films is achieved by condensing the plasma of anode material generated using Thermionic Vacuum Arc (TVA) under high vacuum conditions onto the surface to be coated. The crystal orientation and morphology of the deposited films were investigated by using XRD, EDX, SEM and AFM. The aim of this study is to search the use of TVA technique to coat magnesium thin films and to determine some of the physical properties of the films generated. Furthermore, this study will contribute to the scientific studies which search the thin films of magnesium or the compounds containing magnesium. In future, this study will be preliminary work to entirely produce magnesium diboride (MgB{sub 2}) superconductor thin film with the TVA technique.

  4. Corrosion mechanism of model zinc-magnesium alloys in atmospheric conditions

    International Nuclear Information System (INIS)

    Prosek, T.; Nazarov, A.; Bexell, U.; Thierry, D.; Serak, J.

    2008-01-01

    Recently, superior corrosion properties of zinc coatings alloyed with magnesium have been reported. Corrosion behaviour of model zinc-magnesium alloys was studied to understand better the protective mechanism of magnesium in zinc. Alloys containing from 1 to 32 wt.% magnesium, pure zinc, and pure magnesium were contaminated with sodium chloride and exposed to humid air for 28 days. Composition of corrosion products was analyzed using infrared spectroscopy (FTIR), ion chromatography (IC), and Auger electron spectroscopy (AES). The exposure tests were completed with scanning Kelvin probe (SKP) and electrochemical measurements. Weight loss of ZnMg alloys with 1-16 wt.% magnesium was lower than that of pure zinc. Up to 10-fold drop in weight loss was found for materials with 4-8 wt.% Mg in the structure. The improved corrosion stability of ZnMg alloys was connected to the presence of an Mg-based film adjacent to the metal surface. It ensured stable passivity in chloride environment and limited the efficiency of oxygen reduction

  5. Nuclear reactor shield including magnesium oxide

    International Nuclear Information System (INIS)

    Rouse, C.A.; Simnad, M.T.

    1981-01-01

    An improvement is described for nuclear reactor shielding of a type used in reactor applications involving significant amounts of fast neutron flux. The reactor shielding includes means providing structural support, neutron moderator material, neutron absorber material and other components, wherein at least a portion of the neutron moderator material is magnesium in the form of magnesium oxide either alone or in combination with other moderator materials such as graphite and iron

  6. Investigation of gel formation and volatilization of acetate acid in magnesium acetate droplets by the optical tweezers.

    Science.gov (United States)

    Lv, Xi-Juan; Wang, Yang; Cai, Chen; Pang, Shu-Feng; Ma, Jia-Bi; Zhang, Yun-Hong

    2018-07-05

    Hygroscopicity and volatility of single magnesium acetate (MgAc 2 ) aerosol particles at various relative humidities (RHs) are studied by a single-beam optical tweezers, and refractive indices (RIs) and morphology are characterized by cavity enhanced Raman spectroscopy. Gel formation and volatilization of acetate acid (HAc) in MgAc 2 droplets are observed. Due to the formation of amorphous gel structure, water transposition in droplets at RH magnesium hydroxide (Mg(OH) 2 ) inclusions are formed in MgAc 2 droplets due to the volatilization of HAc, and whispering gallery modes (WGMs) of MgAc 2 droplets in the Raman spectrum quench after 50,000 s. In sharp contrast, after 86,000 s at RH ≈ 70%, NaAc droplets are in well-mixed liquid states, containing soluble sodium hydroxide (NaOH). At this state, the RI of NaAc droplet is increased, and the quenching of WGMs is not observable. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Fragmentation pathways of tungsten hexacarbonyl clusters upon electron ionization

    Energy Technology Data Exchange (ETDEWEB)

    Neustetter, M.; Jabbour Al Maalouf, E.; Denifl, S., E-mail: Stephan.Denifl@uibk.ac.at, E-mail: plimaovieira@fct.unl.pt [Institut für Ionenphysik und Angewandte Physik, Universität Innsbruck, Technikerstrasse 25, A-6020 Innsbruck (Austria); Limão-Vieira, P., E-mail: Stephan.Denifl@uibk.ac.at, E-mail: plimaovieira@fct.unl.pt [Institut für Ionenphysik und Angewandte Physik, Universität Innsbruck, Technikerstrasse 25, A-6020 Innsbruck (Austria); Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, 2829-516 Caparica (Portugal)

    2016-08-07

    Electron ionization of neat tungsten hexacarbonyl (W(CO){sub 6}) clusters has been investigated in a crossed electron-molecular beam experiment coupled with a mass spectrometer system. The molecule is used for nanofabrication processes through electron beam induced deposition and ion beam induced deposition techniques. Positive ion mass spectra of W(CO){sub 6} clusters formed by electron ionization at 70 eV contain the ion series of the type W(CO){sub n}{sup +} (0 ≤ n ≤ 6) and W{sub 2}(CO){sub n}{sup +} (0 ≤ n ≤ 12). In addition, a series of peaks are observed and have been assigned to WC(CO){sub n}{sup +} (0 ≤ n ≤ 3) and W{sub 2}C(CO){sub n}{sup +} (0 ≤ n ≤ 10). A distinct change of relative fragment ion intensity can be observed for clusters compared to the single molecule. The characteristic fragmentation pattern obtained in the mass spectra can be explained by a sequential decay of the ionized organometallic, which is also supported by the study of the clusters when embedded in helium nanodroplets. In addition, appearance energies for the dissociative ionization channels for singly charged ions have been estimated from experimental ion efficiency curves.

  8. On the effect of interaction of molybdenum trioxide and magnesium oxide in water

    International Nuclear Information System (INIS)

    Bunin, V.M.; Karelin, A.I.; Solov'eva, L.N.

    1992-01-01

    Interaction of molybdenum trioxide and magnesium oxide in water was studied. It is shown that molybdenum trioxide forms consecutively magnesium molybdate, dimolybdate and magnesium polymolybdates with magnesium oxide

  9. In situ probing of cholesterol in astrocytes at the single-cell level using laser desorption ionization mass spectrometric imaging with colloidal silver.

    Science.gov (United States)

    Perdian, D C; Cha, Sangwon; Oh, Jisun; Sakaguchi, Donald S; Yeung, Edward S; Lee, Young Jin

    2010-04-30

    Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations at the cellular level. Published in 2010 by John Wiley & Sons, Ltd.

  10. Magnesium and Osteoporosis: Current State of Knowledge and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Jeanette A. M. Maier

    2013-07-01

    Full Text Available A tight control of magnesium homeostasis seems to be crucial for bone health. On the basis of experimental and epidemiological studies, both low and high magnesium have harmful effects on the bones. Magnesium deficiency contributes to osteoporosis directly by acting on crystal formation and on bone cells and indirectly by impacting on the secretion and the activity of parathyroid hormone and by promoting low grade inflammation. Less is known about the mechanisms responsible for the mineralization defects observed when magnesium is elevated. Overall, controlling and maintaining magnesium homeostasis represents a helpful intervention to maintain bone integrity.

  11. Special metallurgy - the electrical butt-welding by flashing of sintered magnesium-magnesium oxide composites (1963); Metallurgie speciale - le soudage electrique en bout par etincelage du composite fritte magnesium-magnesie (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Charleux, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    Electrical resistance welding has become quite important since World War II because of the need of a high yield in aeronautical production. Progress has been due in particular to the improvements made in electronically controlled apparatus making possible the automatic control of welding. For the butt-welding of sections requiring either a high production rate or a high quality weld, the flash butt-welding system has been very much developed these last few years. The use of this welding method is of great importance in the field of the bonding of oxidisable metals such as magnesium or aluminium and its alloys, because the welded joint is free from oxides. This study consists of general considerations on the flash-welding process with regard to temperature distribution in the parts during welding, and to electrical phenomena connected with flashing. Besides this general or theoretical section, we have applied the welding process to the bonding of sintered magnesium, a magnesium-magnesium oxide composite, whose use as a structural element in nuclear reactors is considered. (author) [French] Le soudage electrique par resistance a pris un essor important depuis la derniere guerre mondiale a cause du besoin de haut rendement pour la production aeronautique. Les progres ont ete possibles surtout par l'amelioration des appareils de commande electronique qui permettent un controle automatique de la soudure. Pour le soudage bout a bout de profiles, demandant soit un haut debit de fabrication, soit une haute qualite du joint soude, le procede de soudage en bout par etincelage a ete tres developpe ces dernieres annees. Ce mode de soudage a un domaine d'utilisation important dans la liaison des metaux oxydables tels le magnesium ou l'aluminium et ses alliages, du fait de la proprete du joint soude exempt d'oxydes. Cette etude comporte une consideration generale du processus de l'etincelage, quant a la repartition de la temperature dans les pieces pendant le soudage et aux

  12. Special metallurgy - the electrical butt-welding by flashing of sintered magnesium-magnesium oxide composites (1963); Metallurgie speciale - le soudage electrique en bout par etincelage du composite fritte magnesium-magnesie (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Charleux, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    Electrical resistance welding has become quite important since World War II because of the need of a high yield in aeronautical production. Progress has been due in particular to the improvements made in electronically controlled apparatus making possible the automatic control of welding. For the butt-welding of sections requiring either a high production rate or a high quality weld, the flash butt-welding system has been very much developed these last few years. The use of this welding method is of great importance in the field of the bonding of oxidisable metals such as magnesium or aluminium and its alloys, because the welded joint is free from oxides. This study consists of general considerations on the flash-welding process with regard to temperature distribution in the parts during welding, and to electrical phenomena connected with flashing. Besides this general or theoretical section, we have applied the welding process to the bonding of sintered magnesium, a magnesium-magnesium oxide composite, whose use as a structural element in nuclear reactors is considered. (author) [French] Le soudage electrique par resistance a pris un essor important depuis la derniere guerre mondiale a cause du besoin de haut rendement pour la production aeronautique. Les progres ont ete possibles surtout par l'amelioration des appareils de commande electronique qui permettent un controle automatique de la soudure. Pour le soudage bout a bout de profiles, demandant soit un haut debit de fabrication, soit une haute qualite du joint soude, le procede de soudage en bout par etincelage a ete tres developpe ces dernieres annees. Ce mode de soudage a un domaine d'utilisation important dans la liaison des metaux oxydables tels le magnesium ou l'aluminium et ses alliages, du fait de la proprete du joint soude exempt d'oxydes. Cette etude comporte une consideration generale du processus de l'etincelage, quant a la repartition de la temperature dans les pieces

  13. Limits to Mercury's Magnesium Exosphere from MESSENGER Second Flyby Observations

    Science.gov (United States)

    Sarantos, Menelaos; Killen, Rosemary M.; McClintock, William E.; Bradley, E. Todd; Vervack, Ronald J., Jr.; Benna, Mehdi; Slavin, James A.

    2011-01-01

    The discovery measurements of Mercury's exospheric magnesium, obtained by the MErcury Surface. Space ENvironment, GEochemistry. and Ranging (MESSENGER) probe during its second Mercury flyby, are modeled to constrain the source and loss processes for this neutral species. Fits to a Chamberlain exosphere reveal that at least two source temperatures are required to reconcile the distribution of magnesium measured far from and near the planet: a hot ejection process at the equivalent temperature of several tens of thousands of degrees K, and a competing, cooler source at temperatures as low as 400 K. For the energetic component, our models indicate that the column abundance that can be attributed to sputtering under constant southward interplanetary magnetic field (IMF) conditions is at least a factor of five less than the rate dictated by the measurements, Although highly uncertain, this result suggests that another energetic process, such as the rapid dissociation of exospheric MgO, may be the main source of the distant neutral component. If meteoroid and micrometeoroid impacts eject mainly molecules, the total amount of magnesium at altitudes exceeding approximately 100 km is found to be consistent with predictions by impact vaporization models for molecule lifetimes of no more than two minutes. Though a sharp increase in emission observed near the dawn terminator region can be reproduced if a single meteoroid enhanced the impact vapor at equatorial dawn, it is much more likely that observations in this region, which probe heights increasingly near the surface, indicate a reservoir of volatile Mg being acted upon by lower-energy source processes.

  14. Treatment with magnesium sulphate in pre-term birth

    DEFF Research Database (Denmark)

    Wolf, Hans; Hegaard, H K; Greisen, G

    2012-01-01

    Premature birth increases a child's risk of cerebral palsy and death. The aim of this work is to investigate the association between treatment with magnesium sulphate during premature deliveries and infants' cerebral palsy and mortality through a meta-analysis of observational studies....... A comprehensive search of the Cochrane Library, EMBASE and the PubMed database from their inceptions to 1 October, 2010 using the keywords 'magnesium sulphate, children/infant/pre-term/premature and cerebral palsy/mortality/morbidity/adverse effects/outcome' identified 11 reports of observational studies. Two...... authors working independently extracted the data. A meta-analysis of the data found an association between magnesium sulphate treatment and a significantly reduced risk of mortality (RR 0.73; 95% CI 0.61-0.89) and cerebral palsy (OR 0.64; 95% CI 0.47-0.89). Antenatal treatment with magnesium sulphate...

  15. Characterization of the whiskerlike products formed by hydriding magnesium metal powders

    DEFF Research Database (Denmark)

    Herley, P. J.; Jones, W.; Vigeholm, Bjørn

    1985-01-01

    The structure of filamentary crystals produced during the hydriding of magnesium powder has been studies in detail. The needles of small dimensions (typically 0.5 μm in diameter) have been identified by electron analytical techniques to be oriented microcrystals of metallic magnesium. Their forma......The structure of filamentary crystals produced during the hydriding of magnesium powder has been studies in detail. The needles of small dimensions (typically 0.5 μm in diameter) have been identified by electron analytical techniques to be oriented microcrystals of metallic magnesium....... Their formation has been ascribed to the melting of localized aluminum impurities within the bulk magnesium to form a liquid eutectic. In the presence of sublimed magnesium vapor and hydrogen (as a carrier gas) a vapor-liquid-solid mechanism operates to produce a rapid unidirectional extension followed...

  16. Magnesium - distribution and basic metabolism | Olhaberry | South ...

    African Journals Online (AJOL)

    Magnesium is extensively distributed in soil, water and plants. It is essential for ehzymatic reactions requiring adenosine triphosphate, and the recommended dietary allowance in man is 5 - 10 mg/kg/d. About 50% of magnesium in man is stored in bone, where it is regulated by parathyroid hormone'and 1,25(OH)2-D3.

  17. A Shortened versus Standard Matched Postpartum Magnesium ...

    African Journals Online (AJOL)

    Magnesium sulphate is currently the most ideal drug for the treatment of eclampsia but its use in Nigeria is still limited due its cost and clinicians inexperience with the drug. The purpose of this study was to determine whether a shortened postpartum course of magnesium sulphate is as effective as the standard Pritchard ...

  18. Magnesium Hydride for Load Levelling Energy Storage

    DEFF Research Database (Denmark)

    Vigeholm, B.

    Some of the magnesium properties essential to the applicability of the reaction Mg+H2⇆MgH2 as a hydrogen storage system have been investigated. Three magnesium powders with particle size smaller than 50 μm average diameter were cycled, over 31, 71 and 151 cycles respectively, at 675K (400°C...

  19. Magnesium nutrition of apple trees. III. Comparison of different methods of magnesium fertilization

    Directory of Open Access Journals (Sweden)

    A. Sadowski

    2015-06-01

    Full Text Available In the period 1969-1973 two experiments were performed in young orchards in Central Poland: a four-year experiment at Julianów, on sandy loamy soil on underlying sand and one-year experiment at Kośmin, on sandy loam soil on clay loam. At Kosmin, in spite of a high Mg content in the subsoil, Mg deficiency symptoms appeared, because of shallow rooting owing to poor aeration. In both experiments, foliar sprays with epsomite were less effective than fertilization to the soil; at Kośmin even eight sprays were less effective than soil dressings. Mg losses from a sandy soil due to leaching were high, particularly where sand was present in the whole profile; under these conditions the least losses of Mg were from split doses of epsomite (Mg3x120. Single doses of epsomite were the most effective in increasing leaf Mg content, reducing Mg deficiency symptoms and promoting growth of trees in the first year after application; in the later years split doses of epsomite and a single initial dose of magnesium lime were more effective. Effects of Mg fertilization on growth and yields of apples were rather slight, when K fertilizer doses were low. No effect of Mg fertilization upon fruit drop and fruit quality was found. Preliminary recommendations for practice are given.

  20. Corrosion Monitoring of PEO-Pretreated Magnesium Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Gnedenkov, A. S.; Sinebryukhov, S. L.; Mashtalyar, D. V.; Gnedenkov, S. V.; Sergienko, V. I. [Institute of Chemistry, Vladivostok (Russian Federation)

    2017-06-15

    The MA8 alloy (formula Mg-Mn-Ce) has been shown to have greater corrosion stability than the VMD10 magnesium alloy (formula Mg-Zn-Zr-Y) in chloride-containing solutions by Scanning Vibrating Electrode Technique (SVET) and by optical microscopy, gravimetry, and volumetry. It has been established that the crucial factor for the corrosion activity of these samples is the occurrence of microgalvanic coupling at the sample surface. The peculiarities of the kinetics and mechanism of the corrosion in the local heterogeneous regions of the magnesium alloy surface were investigated by localized electrochemical techniques. The stages of the corrosion process in artificial defects in the coating obtained by plasma electrolytic oxidation (PEO) at the surface of the MA8 magnesium alloy were also studied. The analysis of the experimental data enabled us to determine that the corrosion process in the defect zone develops predominantly at the magnesium/coating interface. Based on the measurements of the corrosion rate of the samples with PEO and composite polymer-containing coatings, the best anticorrosion properties were displayed by the composite polymer-containing coatings.

  1. Theoretical study of the ionization of B2H5

    International Nuclear Information System (INIS)

    Curtiss, L.A.; Pople, J.A.

    1989-01-01

    Ab initio molecular orbital calculations at the G1 level of theory have been carried out on neutral B 2 H 5 radical, doubly bridged B 2 H + 5 cation, and the first triplet excited state of B 2 H + 5 . Singly bridged B 2 H 5 is 4.0 kcal/mol (without zero-point energies) more stable than doubly bridged B 2 H 5 . Based on this work and previous theoretical work on triply bridged B 2 H + 5 , ionization potentials (vertical and adiabatic) are determined for B 2 H 5 . The adiabatic ionization potentials of the two B 2 H 5 structures are 6.94 eV (singly bridged) and 7.53 eV (doubly bridged). A very large difference is found between the vertical and adiabatic ionization potentials (3.37 eV) of the singly bridged B 2 H 5 structure. The first triplet state of B 2 H + 5 is found to be 4.55 eV higher in energy than the lowest energy B 2 H + 5 cation (triply bridged). The results of this theoretical study support the interpretation of Ruscic, Schwarz, and Berkowitz of their recent photoionization measurements on B 2 H 5

  2. Effects of oral magnesium supplementation on inflammatory markers in middle-aged overweight women

    Directory of Open Access Journals (Sweden)

    Nazanin Moslehi

    2012-01-01

    Full Text Available Background: This study aimed to investigate whether magnesium supplementation might affect serum magnesium, high sensitive C-reactive protein (hs-CRP, plasma fibrinogen, and interleukin 6 (IL-6 levels in healthy middle-aged overweight women. The relationships, if any, between serum magnesium and the inflammatory markers were also examined cross-sectionally in the entire participants at the beginning of the study. Materials and Methods: This double-blinded, placebo-controlled, randomized trial included 74 middle-aged overweight women. Participants were randomly assigned to receive either 250 mg magnesium as magnesium oxide or placebo daily for 8 weeks. Serum magnesium, hs-CRP, fibrinogen and IL-6 concentrations were measured before and after the intervention. Results: Serum magnesium was found to be inversely correlated with hs-CRP (r s =−0.22, P=0.05 in the entire participants at baseline. Serum hs-CRP declined significantly in both groups as compared with baseline values (median change=0.8 mg/L; P Magnesium= 0.03, P Placebo 0.001. Plasma fibrinogen decreased significantly, by 9%, in the magnesium group at the end of week 8 compared to baseline (P=0.001. Mean concentration of IL-6 was significantly increased in the magnesium group comparing the baseline value(P=0.001. However hs-CRP, fibrinogen and IL-6 levels at week 8 or any changes during the study were not statistically different between the two groups. Serum magnesium showed no significant changes in any groups. Conclusions: Serum magnesium had a significant inverse correlation with hs-CRP. In the present study, magnesium as magnesium oxide, 250 mg/day, for 8 weeks did not significantly attenuate inflammatory markers in the magnesium group as compared to the placebo.

  3. Loss of insulin-induced activation of TRPM6 magnesium channels results in impaired glucose tolerance during pregnancy.

    NARCIS (Netherlands)

    Nair, A.V.; Hocher, B.; Verkaart, S.A.J.; Zeeland, F. van; Pfab, T.; Slowinski, T.; Chen, Y.P.; Schlingmann, K.P.; Schaller, A.; Gallati, S.; Bindels, R.J.M.; Konrad, M.; Hoenderop, J.G.J.

    2012-01-01

    Hypomagnesemia affects insulin resistance and is a risk factor for diabetes mellitus type 2 (DM2) and gestational diabetes mellitus (GDM). Two single nucleotide polymorphisms (SNPs) in the epithelial magnesium channel TRPM6 (V(1393)I, K(1584)E) were predicted to confer susceptibility for DM2. Here,

  4. Magnesium silicide production and silane synthesis on its basis

    International Nuclear Information System (INIS)

    Taurbaev, T.I.; Mukashev, F.A.; Manakov, S.M.; Francev, U.V.; Kalblanbekov, B.M.; Akhter, P.; Abbas, M.; Hussain, A.

    2003-01-01

    We had developed an alternative method of production of magnesium silicide with use of ferroalloys of silicon. Magnesium silicide is raw material for silane synthesis. The essence of the method consist of sintering FS -75 (ferrosilicium with 75 % of silicon and 25 % of iron, made by ferroalloy factories) with metal magnesium at temperature of 650 deg. C. The X-ray analysis has shown formation of magnesium silicide. That is further used for synthesis of silane. The output of silane is 60 % in respect of the contents of silicon. After removing the water vapors the mass-spectrometer analysis has estimated the purity of silane as 99.95 % with no detection of phosphine and diborane. (author)

  5. Polyanthraquinone-Based Organic Cathode for High-Performance Rechargeable Magnesium-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Baofei [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Huang, Jinhua [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Feng, Zhenxing [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Zeng, Li [Applied Physics Program, Department of Materials Science and Engineering and Department of Physics and Astronomy, Northwestern University, Evanston IL 60208 USA; He, Meinan [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Zhang, Lu [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Vaughey, John T. [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Bedzyk, Michael J. [Applied Physics Program, Department of Materials Science and Engineering and Department of Physics and Astronomy, Northwestern University, Evanston IL 60208 USA; Fenter, Paul [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Zhang, Zhengcheng [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Burrell, Anthony K. [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA; Liao, Chen [Joint Center for Energy Storage Research, Chemical Science and Engineering Division, Argonne National Laboratory, Lemont IL 60439 USA

    2016-05-09

    Two anthraquinone-based polymers aiming at improving the capacity and voltage of magnesium ion batteries, were synthesized and characterized. The excellent battery cycling performance was demonstrated with the electrolyte consisting of magnesium bis(hexamethyldisilazide) and magnesium chloride.

  6. Spectral irradiance of singly and doubly ionized zinc in low-intensity laser-plasma ultraviolet light sources

    Science.gov (United States)

    Szilagyi, John; Parchamy, Homaira; Masnavi, Majid; Richardson, Martin

    2017-01-01

    The absolute spectral irradiances of laser-plasmas produced from planar zinc targets are determined over a wavelength region of 150 to 250 nm. Strong spectral radiation is generated using 60 ns full-width-at-half-maximum, 1.0 μm wavelength laser pulses with incident laser intensities as low as ˜5 × 108 W cm-2. A typical radiation conversion efficiency of ˜2%/2πsr is measured. Numerical calculations using a comprehensive radiation-hydrodynamics model reveal the strong experimental spectra to originate mainly from 3d94s4p-3d94s2, 3d94s4d-3d94s4p, and 3d94p-3d94s, 3d94d-3d94p unresolved-transition arrays in singly and doubly ionized zinc, respectively.

  7. Microwave ionization and excitation of Ba Rydberg atoms

    International Nuclear Information System (INIS)

    Eichmann, U.; Dexter, J.L.; Xu, E.Y.; Gallagher, T.F.

    1989-01-01

    We have investigated ionization and excitation of the Ba 6sn s 1 S 0 and 6snd 1,3 D 2 series in strong microwave fields. The observed microwave ionization threshold fields, scaling as 0.28 n -5 , and the state mixing fields cannot be completely explained in terms of a single cycle Landau-Zener model. However, by taking into account multiphoton resonant transitions driven by many cycles of the microwave field we have been able to interpret the data. In particular multi-photon transitions have been found to be responsible for apparent resonance structures and for the unexpectedly low mixing fields. Not surprisingly, doubly excited valence states introduce irregularities into both the microwave ionization and the state mixing field values. (orig.)

  8. Convenient method of simultaneously analyzing aluminum and magnesium in pharmaceutical dosage forms using californium-252 thermal neutron activation

    International Nuclear Information System (INIS)

    Landolt, R.R.; Hem, S.L.

    1983-01-01

    A commercial antacid suspension containing aluminum hydroxide and magnesium hydroxide products was used as a model sample to study the use of a californium-252 thermal neutron activation as a method for quantifying aluminum content as well as for the simultaneous assay of aluminum and magnesium. A 3.5-micrograms californium-252 source was used for the activation, and the induced aluminum-28 and magnesium-27 activity was simultaneously measured by sodium iodide crystal gamma-ray spectrometry using dual single-channel analyzers and scalers. The antacid suspension was contained in a chamber designed with the unique capability of serving as the container for counting the induced radioactivity in addition to being the irradiation chamber itself. This pilot study demonstrated that use of more intense californium-252 sources, which are commonly available, would provide a method that is competitive with the ethylenediaminetetraacetic acid titration method in precision and in other aspects as well

  9. Magnesium and uranium ignition in different gaseous atmospheres; Inflammabilite du magnesium et de l'uranium dans l'air et le gaz carbonique

    Energy Technology Data Exchange (ETDEWEB)

    Darras, R; Baque, P; Leclercq, D [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Magnesium, uranium and some of their alloys burning temperatures have been systematically determined in an air or carbon dioxide atmosphere, either dry or wet. Two different ways of heating have been used: either continuously rising up the temperature, or heating to and then maintaining a constant temperature. The results are clearly different in the two cases. Besides, if moisture has little effect on the magnesium burning temperatures in air, it does lower them by about 130-140 deg. C in CO{sub 2}. The differences of sight between the burning of magnesium and uranium have been noticed; this leads to distinguish between an 'ignition' and an 'inflammation'. (author) [French] Les temperatures auxquelles apparait la combustion vive du magnesium, de l'uranium et certains de leurs alliages ont ete determinees systematiquement dans l'air et le gaz carbonique, soit secs, soit humidifies. On a mis en evidence l'influence du mode de chauffage sur les resultats: soit montee en temperature continue, soit stabilisation a partir d'une certaine temperature. En outre, si la presence d'humidite affecte peu les temperatures de combustion vive du magnesium dans l'air, elle les abaisse de 130 a 140 deg. C dans le gaz carbonique. Les differences d'aspect entre la combustion vive du magnesium et de l'uranium ont egalement ete remarquees, ce qui amene notamment a distinguer une 'ignition' d'une 'inflammation'. (auteur)

  10. Electron-impact ionization of multicharged ions at ORNL: 1985--1992

    International Nuclear Information System (INIS)

    Gregory, D.C.; Bannister, M.E.

    1994-07-01

    Absolute cross sections are presented in graphs and tables for single ionization of forty-one ions, multiple ionization of four ions, and for dissociation and ionization of two molecular ions by electron impact. This memo is the third in a series of manuscripts summarizing previously published as well as unpublished ionization cross section measurements at ORNL; contents of the two previous memos are also referenced in this work. All work tabulated in this memo involved ion beams generated in the ORNL-ECR ion source and utilized the ORNL electron-ion crossed beams apparatus. Target ions range from atomic number Z = 8 (oxygen) to Z = 92 (uranium) in initial charge states from +1 to +16. Electron impact energies typically range from threshold to 1500 eV

  11. Cobalt and magnesium impurity diffusion in Ni1-δO single crystals

    International Nuclear Information System (INIS)

    Boussetta, H.; Tabet, N.; Monty, C.

    1992-01-01

    Co and Mg diffusion coefficients have been measured in NiO as a function of temperature at constant oxygen partial pressures p O2 =0.21 atm and 10 -4 atm and as a function of psub(O 2 ) at T=1 245degC. The results are well represented by the relations: D Mg (cm 2 s -1 )≅1.45x10 -2 p O2 (atm) 0.172 exp[-2.58 (eV)/kt]; D Co (cm 2 s -1 )≅5.15x10 -2 p O2 (atm) 0.175 exp[-2.54 (eV)/kT]. Analyzing these results by comparison to nickel self-diffusion and to data on vacancy/impurity binding enthalpies, on correlation factors and on migration enthalpies, leads to a detailed analysis of the impurity/vancancy interactions. It shows that cobalt and magnesium interact rather tightly with V Ni '' during the exchange jumps and practically no when they are in stable positions. (orig.)

  12. Extraction of magnesium from calcined dolomite ore using hydrochloric acid leaching

    Science.gov (United States)

    Royani, Ahmad; Sulistiyono, Eko; Prasetiyo, Agus Budi; Subagja, Rudi

    2018-05-01

    Magnesium is widely used in varieties industrial sector. Dolomite is one source of magnesium besides seawater. The extraction of magnesium from dolomite ores can be done by leaching process. In this work, the dolomite leaching to extract magnesium by hydrochloric acid was investigated. The leaching experiments were performed in a spherical glass batch reactor having a capacity of 1000 ml. The effects of the stirring speed, acid concentration, reaction temperature and liquid-solid ratio for each reaction time of 1; 2; and 3 h on the Mg leaching have been evaluated. 5 ml of solution sample were collected from the leached solutions, then it was filtered prior to analysis by ICP OES. The experimental results show that the magnesium extraction increases along with the increase of acid concentration, liquid-solid ratio and temperature. The optimum conditions for magnesium extraction were achieved at temperature 75 °C, extraction time 3 h, the HCl concentration of 2 M, the liquid-solid ratio 20 ml/g and stirring speed of 400 rpm. At this condition 98, 82 % of magnesium were extracted from dolomite. The conclusion obtained from this leaching process is that the magnesium can be extracted from dolomite by using hydrochloric acid solutions.

  13. Evaluation of magnesium ions release, biocorrosion, and hemocompatibility of MAO/PLLA-modified magnesium alloy WE42.

    Science.gov (United States)

    Lu, Ping; Cao, Lu; Liu, Yin; Xu, Xinhua; Wu, Xiangfeng

    2011-01-01

    Magnesium alloys may potentially be applied as biodegradable metallic materials in cardiovascular stent. However, the high corrosion rate hinders its clinical application. In this study, a new approach was adopted to control the corrosion rate by fabricating a biocompatible micro-arc oxidation/poly-L-lactic acid (MAO/PLLA) composite coating on the magnesium alloy WE42 substrate and the biocompatibility of the modified samples was investigated. The scanning electronic microscope (SEM) images were used to demonstrate the morphology of the samples before and after being submerged in hanks solution for 4 weeks. The degradation was evaluated through the magnesium ions release rate and electrochemical impedance spectroscopy (EIS) test. The biocompatibility of the samples was demonstrated by coagulation time and hemolysis behavior. The result shows that the poly-L-lactic acid (PLLA) effectively improved the corrosion resistance by sealing the microcracks and microholes on the surface of the MAO coating. The modified samples had good compatibility. © 2010 Wiley Periodicals, Inc.

  14. The High Strain Rate Deformation Behavior of High Purity Magnesium and AZ31B Magnesium Alloy

    Science.gov (United States)

    Livescu, Veronica; Cady, Carl M.; Cerreta, Ellen K.; Henrie, Benjamin L.; Gray, George T.

    The deformation in compression of pure magnesium and AZ31B magnesium alloy, both with a strong basal pole texture, has been investigated as a function of temperature, strain rate, and specimen orientation. The mechanical response of both metals is highly dependent upon the orientation of loading direction with respect to the basal pole. Specimens compressed along the basal pole direction have a high sensitivity to strain rate and temperature and display a concave down work hardening behavior. Specimens loaded perpendicularly to the basal pole have a yield stress that is relatively insensitive to strain rate and temperature and a work hardening behavior that is parabolic and then linearly upwards. Both specimen orientations display a mechanical response that is sensitive to temperature and strain rate. Post mortem characterization of the pure magnesium was conducted on a subset of specimens to determine the microstructural and textural evolution during deformation and these results are correlated with the observed work hardening behavior and strain rate sensitivities were calculated.

  15. Sol – Gel synthesis and characterization of magnesium peroxide nanoparticles

    International Nuclear Information System (INIS)

    Jaison, J; Chan, Y S; Ashok raja, C; Balakumar, S

    2015-01-01

    Magnesium peroxide is an excellent source of oxygen in agriculture applications, for instance it is used in waste management as a material for soil bioremediation to remove contaminants from polluted underground water, biological wastes treatment to break down hydrocarbon, etc. In the present study, sol-gel synthesis of magnesium peroxide (MgO 2 ) nanoparticles is reported. Magnesium peroxide is odourless; fine peroxide which releases oxygen when reacts with water. During the sol-gel synthesis, the magnesium malonate intermediate is formed which was then calcinated to obtain MgO 2 nanoparticles. The synthesized nanoparticles were characterized using Thermo gravimetric -Differential Thermal Analysis (TG- DTA), X-Ray Diffraction studies (XRD) and High Resolution Transmission Electron Microscope (HRTEM). Our study provides a clear insight that the formation of magnesium malonate during the synthesis was due to the reaction between magnesium acetate, oxalic acid and ethanol. In our study, we can conclude that the calcination temperature has a strong influence on particle size, morphology, monodispersity and the chemistry of the particles. (paper)

  16. Effective and Environmentally Friendly Nickel Coating on the Magnesium Alloy

    Directory of Open Access Journals (Sweden)

    Ivana Škugor Rončević

    2016-12-01

    Full Text Available The low density and good mechanical properties make magnesium and its alloys attractive construction materials in the electronics, automotive, and aerospace industry, together with application in medicine due to their biocompatibility. Magnesium AZ91D alloy is an alloy with a high content of aluminum, whose mechanical properties overshadow the low corrosion resistance caused by the composition of the alloy and the existence of two phases: α magnesium matrix and β magnesium aluminum intermetallic compound. To improve the corrosion resistance, it is necessary to find an effective protection method for the alloy surface. Knowing and predicting electrochemical processes is an essential for the design and optimization of protective coatings on magnesium and its alloys. In this work, the formations of nickel protective coatings on the magnesium AZ91D alloy surface by electrodeposition and chemical deposition, are presented. For this purpose, environmentally friendly electrolytes were used. The corrosion resistance of the protected alloy was determined in chloride medium using appropriate electrochemical techniques. Characterization of the surface was performed with highly sophisticated surface-analytical methods.

  17. Electron-impact-ionization dynamics of S F6

    Science.gov (United States)

    Bull, James N.; Lee, Jason W. L.; Vallance, Claire

    2017-10-01

    A detailed understanding of the dissociative electron ionization dynamics of S F6 is important in the modeling and tuning of dry-etching plasmas used in the semiconductor manufacture industry. This paper reports a crossed-beam electron ionization velocity-map imaging study on the dissociative ionization of cold S F6 molecules, providing complete, unbiased kinetic energy distributions for all significant product ions. Analysis of these distributions suggests that fragmentation following single ionization proceeds via formation of S F5 + or S F3 + ions that then dissociate in a statistical manner through loss of F atoms or F2, until most internal energy has been liberated. Similarly, formation of stable dications is consistent with initial formation of S F4 2 + ions, which then dissociate on a longer time scale. These data allow a comparison between electron ionization and photoionization dynamics, revealing similar dynamical behavior. In parallel with the ion kinetic energy distributions, the velocity-map imaging approach provides a set of partial ionization cross sections for all detected ionic fragments over an electron energy range of 50-100 eV, providing partial cross sections for S2 +, and enables the cross sections for S F4 2 + from S F+ to be resolved.

  18. On the SIMS Ionization Probability of Organic Molecules.

    Science.gov (United States)

    Popczun, Nicholas J; Breuer, Lars; Wucher, Andreas; Winograd, Nicholas

    2017-06-01

    The prospect of improved secondary ion yields for secondary ion mass spectrometry (SIMS) experiments drives innovation of new primary ion sources, instrumentation, and post-ionization techniques. The largest factor affecting secondary ion efficiency is believed to be the poor ionization probability (α + ) of sputtered material, a value rarely measured directly, but estimated to be in some cases as low as 10 -5 . Our lab has developed a method for the direct determination of α + in a SIMS experiment using laser post-ionization (LPI) to detect neutral molecular species in the sputtered plume for an organic compound. Here, we apply this method to coronene (C 24 H 12 ), a polyaromatic hydrocarbon that exhibits strong molecular signal during gas-phase photoionization. A two-dimensional spatial distribution of sputtered neutral molecules is measured and presented. It is shown that the ionization probability of molecular coronene desorbed from a clean film under bombardment with 40 keV C 60 cluster projectiles is of the order of 10 -3 , with some remaining uncertainty arising from laser-induced fragmentation and possible differences in the emission velocity distributions of neutral and ionized molecules. In general, this work establishes a method to estimate the ionization efficiency of molecular species sputtered during a single bombardment event. Graphical Abstract GRAPHICAL ABSTRACT TEXT HERE] -->.

  19. Magnesium, hemostasis, and outcomes in patients with intracerebral hemorrhage.

    Science.gov (United States)

    Liotta, Eric M; Prabhakaran, Shyam; Sangha, Rajbeer S; Bush, Robin A; Long, Alan E; Trevick, Stephen A; Potts, Matthew B; Jahromi, Babak S; Kim, Minjee; Manno, Edward M; Sorond, Farzaneh A; Naidech, Andrew M; Maas, Matthew B

    2017-08-22

    We tested the hypothesis that admission serum magnesium levels are associated with hematoma volume, hematoma growth, and functional outcomes in patients with intracerebral hemorrhage (ICH). Patients presenting with spontaneous ICH were enrolled in an observational cohort study that prospectively collected demographic, clinical, laboratory, radiographic, and outcome data. We performed univariate and adjusted multivariate analyses to assess for associations between serum magnesium levels and initial hematoma volume, final hematoma volume, and in-hospital hematoma growth as radiographic measures of hemostasis, and functional outcome measured by the modified Rankin Scale (mRS) at 3 months. We included 290 patients for analysis. Admission serum magnesium was 2.0 ± 0.3 mg/dL. Lower admission magnesium levels were associated with larger initial hematoma volumes on univariate ( p = 0.02), parsimoniously adjusted ( p = 0.002), and fully adjusted models ( p = 0.006), as well as greater hematoma growth ( p = 0.004, p = 0.005, and p = 0.008, respectively) and larger final hematoma volumes ( p = 0.02, p = 0.001, and p = 0.002, respectively). Lower admission magnesium level was associated with worse functional outcomes at 3 months (i.e., higher mRS; odds ratio 0.14, 95% confidence interval 0.03-0.64, p = 0.011) after adjustment for age, admission Glasgow Coma Scale score, initial hematoma volume, time from symptom onset to initial CT, and hematoma growth, with evidence that the effect of magnesium is mediated through hematoma growth. These data support the hypothesis that magnesium exerts a clinically meaningful influence on hemostasis in patients with ICH. © 2017 American Academy of Neurology.

  20. Dielectric behaviour of sodium and potassium doped magnesium ...

    Indian Academy of Sciences (India)

    Dielectric behaviour of sodium and potassium doped magnesium titanate. VISHNU SHANKER. ∗. , SANTOSH KUMAR and T SURENDAR. Department of Chemistry, National Institute of Technology, Warangal 506 004, India. MS received 10 November 2011; revised 27 February 2012. Abstract. Pure phase of magnesium ...

  1. Post traumatic tetanus and role magnesium sulphate

    International Nuclear Information System (INIS)

    Sikendr, R.I.; Samad, B.U.; Memon, M.I.

    2009-01-01

    Tetanus is a life threatening disease. Reported mortality for tetanus is 15-39%. Conventional treatment includes heavy sedation and artificial ventilation. Complications resulting from long term heavy sedation and artificial ventilation contribute to 60% of the total mortality caused by tetanus. In this study magnesium sulphate was used to reduce the need for sedation and artificial ventilation. Objectives of this prospective study were to determine the role of magnesium sulphate in post traumatic tetanus. The study was carried out in surgical Intensive Care at Pakistan Institute of Medical Sciences (PIMS), Islamabad from Jan 2004 to Dec 2007. Forty-four patients presented during this period and 33 patients were included in the study. All patients had tracheostomy done within 48 hours. Every patient was started Magnesium Sulphate therapy for control of spasms after sending baseline investigations. Patients were given ventilatory support when needed. All data was entered in well structured proforma. SPSS-10 was used to analyse data. Thirty-three patients were included in the study and all patients were given magnesium sulphate. Out of these, 45.5% cases were grade 4 tetanus, 73.6% and 63.3% cases did not require artificial ventilation and additional sedation respectively, 51.1% patients remained free of complications of tetanus. Overall mortality was 30.3%. Use of Magnesium Sulphate is safe and reduces the need for sedation and artificial ventilation in high grade tetanus thus contributing to survival benefit in adult post-traumatic tetanus cases. (author)

  2. Recent attoclock measurements of strong field ionization

    International Nuclear Information System (INIS)

    Pfeiffer, Adrian N.; Cirelli, Claudio; Smolarski, Mathias; Keller, Ursula

    2013-01-01

    Highlights: ► The attoclock measures time by electron streaking with elliptically polarized light. ► Precision measurements reveal details about the laser-induced tunneling current flow. ► Multielectron effects play an important role when the polarizability is large. ► Double ionization experiments show evidence of novel electron correlation mechanisms. - Abstract: The attoclock is a powerful, new, and unconventional experimental tool to study fundamental attosecond dynamics on an atomic scale. We have demonstrated the first attoclock with the goal to measure the tunneling delay time in laser-induced ionization of helium and argon atoms, with surprising results. It was found that the time delay in tunneling is zero for helium and argon atoms within the experimental uncertainties of a few 10’s of attoseconds. Furthermore we showed that the single active electron approximation is not sufficient even for atoms such as argon and the parent-ion interaction is much more complex than normally assumed. For double ionization of argon we found again surprising results because the ionization time of the first electron is in good agreement with the predictions, whereas the ionization of the second electron occurs significantly earlier than predicted and the two electrons exhibit some unexpected correlation

  3. Recent attoclock measurements of strong field ionization

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiffer, Adrian N., E-mail: apfeiff@phys.ethz.ch [Physics Department, ETH Zurich, 8093 Zurich (Switzerland); Cirelli, Claudio; Smolarski, Mathias; Keller, Ursula [Physics Department, ETH Zurich, 8093 Zurich (Switzerland)

    2013-03-12

    Highlights: ► The attoclock measures time by electron streaking with elliptically polarized light. ► Precision measurements reveal details about the laser-induced tunneling current flow. ► Multielectron effects play an important role when the polarizability is large. ► Double ionization experiments show evidence of novel electron correlation mechanisms. - Abstract: The attoclock is a powerful, new, and unconventional experimental tool to study fundamental attosecond dynamics on an atomic scale. We have demonstrated the first attoclock with the goal to measure the tunneling delay time in laser-induced ionization of helium and argon atoms, with surprising results. It was found that the time delay in tunneling is zero for helium and argon atoms within the experimental uncertainties of a few 10’s of attoseconds. Furthermore we showed that the single active electron approximation is not sufficient even for atoms such as argon and the parent-ion interaction is much more complex than normally assumed. For double ionization of argon we found again surprising results because the ionization time of the first electron is in good agreement with the predictions, whereas the ionization of the second electron occurs significantly earlier than predicted and the two electrons exhibit some unexpected correlation.

  4. Comparison of Selective Laser Melted Titanium and Magnesium Implants Coated with PCL

    Science.gov (United States)

    Matena, Julia; Petersen, Svea; Gieseke, Matthias; Teske, Michael; Beyerbach, Martin; Kampmann, Andreas; Escobar, Hugo Murua; Gellrich, Nils-Claudius; Haferkamp, Heinz; Nolte, Ingo

    2015-01-01

    Degradable implant material for bone remodeling that corresponds to the physiological stability of bone has still not been developed. Promising degradable materials with good mechanical properties are magnesium and magnesium alloys. However, excessive gas production due to corrosion can lower the biocompatibility. In the present study we used the polymer coating polycaprolactone (PCL), intended to lower the corrosion rate of magnesium. Additionally, improvement of implant geometry can increase bone remodeling. Porous structures are known to support vessel ingrowth and thus increase osseointegration. With the selective laser melting (SLM) process, defined open porous structures can be created. Recently, highly reactive magnesium has also been processed by SLM. We performed studies with a flat magnesium layer and with porous magnesium implants coated with polymers. The SLM produced magnesium was compared with the titanium alloy TiAl6V4, as titanium is already established for the SLM-process. For testing the biocompatibility, we used primary murine osteoblasts. Results showed a reduced corrosion rate and good biocompatibility of the SLM produced magnesium with PCL coating. PMID:26068455

  5. Highly informative multiclass profiling of lipids by ultra-high performance liquid chromatography - Low resolution (quadrupole) mass spectrometry by using electrospray ionization and atmospheric pressure chemical ionization interfaces.

    Science.gov (United States)

    Beccaria, Marco; Inferrera, Veronica; Rigano, Francesca; Gorynski, Krzysztof; Purcaro, Giorgia; Pawliszyn, Janusz; Dugo, Paola; Mondello, Luigi

    2017-08-04

    A simple, fast, and versatile method, using an ultra-high performance liquid chromatography system coupled with a low resolution (single quadrupole) mass spectrometer was optimized to perform multiclass lipid profiling of human plasma. Particular attention was made to develop a method suitable for both electrospray ionization and atmospheric pressure chemical ionization interfaces (sequentially in positive- and negative-ion mode), without any modification of the chromatographic conditions (mobile phase, flow-rate, gradient, etc.). Emphasis was given to the extrapolation of the structural information based on the fragmentation pattern obtained using atmospheric pressure chemical ionization interface, under each different ionization condition, highlighting the complementary information obtained using the electrospray ionization interface, of support for related molecule ions identification. Furthermore, mass spectra of phosphatidylserine and phosphatidylinositol obtained using the atmospheric pressure chemical ionization interface are reported and discussed for the first time. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Study of near-critical states of liquid-vapor phase transition of magnesium

    International Nuclear Information System (INIS)

    Emelyanov, A N; Shakhray, D V; Golyshev, A A

    2015-01-01

    Study of thermodynamic parameters of magnesium in the near-critical point region of the liquid-vapor phase transition and in the region of metal-nonmetal transition was carried out. Measurements of the electrical resistance of magnesium after shock compression and expansion into gas (helium) environment in the process of isobaric heating was carried out. Heating of the magnesium surface by heat transfer with hot helium was performed. The registered electrical resistance of expanded magnesium was about 10 4 -10 5 times lower than the electrical resistance of the magnesium under normal condition at the density less than the density of the critical point. Thus, metal-nonmetal transition was found in magnesium. (paper)

  7. Corrosion of pure magnesium under thin electrolyte layers

    International Nuclear Information System (INIS)

    Zhang Tao; Chen Chongmu; Shao Yawei; Meng Guozhe; Wang Fuhui; Li Xiaogang; Dong Chaofang

    2008-01-01

    The corrosion behavior of pure magnesium was investigated by means of cathodic polarization curve, electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) under aerated and deaerated thin electrolyte layers (TEL) with various thicknesses. Based on shot noise theory and stochastic theory, the EN results were quantitatively analyzed by using the Weibull and Gumbel distribution function, respectively. The results show that the cathodic process of pure magnesium under thin electrolyte layer was dominated by hydrogen reduction. With the decreasing of thin electrolyte layer thickness, cathodic process was retarded slightly while the anodic process was inhibited significantly, which indicated that both the cathodic and anodic process were inhibited in the presence of oxygen. The absence of oxygen decreased the corrosion resistance of pure magnesium in case of thin electrolyte layer. The corrosion was more localized under thin electrolyte layer than that in bulk solution. The results also demonstrate that there exist two kinds of effects for thin electrolyte layer on the corrosion behavior of pure magnesium: (1) the rate of pit initiation was evidently retarded compared to that in bulk solution; (2) the probability of pit growth oppositely increased. The corrosion model of pure magnesium under thin electrolyte layer was suggested in the paper

  8. Ionization of a two-electron atom in a strong electromagnetic field

    International Nuclear Information System (INIS)

    Ovodova, O.V.; Popov, A.M.; Tikhonova, O.V.

    1997-01-01

    A one-dimensional model of a helium atom in an intense field of a femtosecond electromagnetic pulse has been constructed using the Hartree technique. 'Exact' calculations have been compared to the approximations of 'frozen' and 'passive' electrons. A nonmonotonic dependence of the single-electron ionization probability on the radiation intensity has been detected. Minima in the ionization probability are due to multiphoton resonances between different atomic states due to the dynamic Stark effect. We suggest that the ionization suppression is due to the interference stabilization in this case

  9. Contribution of stable isotopes to the study of pharmacokinetics of magnesium salts; Apport des isotopes stables a l'etude de la pharmacocinetique de sels de magnesium

    Energy Technology Data Exchange (ETDEWEB)

    Benech, H

    1999-05-28

    The use of stable isotopes as labels is becoming an attractive tool for the study of magnesium behavior in humans. It has been used two stable isotopes of magnesium, {sup 25}Mg and {sup 26}Mg, to measure the absolute bioavailability of a pharmaceutical form of magnesium. (N.C.)

  10. Friction welding of AZ31 magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Tsujino, R.; Ochi, H. [Osaka Inst. of Tech., Osaka (Japan); Kawai, G. [Osaka Sangyo Univ., Osaka (Japan); Yamaguchi, H.; Ogawa, K. [Osaka Prefecture Univ., Osaka (Japan); Suga, Y. [Keio Univ., Kanagawa (Japan)

    2003-07-01

    In this paper, for an acceleration of utilization of magnesium alloy which is being interested in recent years, friction welding of AZ31 magnesium alloy was carried out, and the joint performance was discussed in relation to the deformation heat input in the upset stage and upset loss as a evaluation factor. Where, the deformation heat input in the upset stage is mechanical work represented by the product of upset speed and axial pressure. As a result, it was made clear that the friction welding of AZ31 magnesium alloy was easy in the atmosphere, and good welded joints without a non- adhesion area at the weld interface could de obtained. Moreover, the evaluation factors discussed were possible to evaluate to joint performance. (orig.)

  11. Corrosion of magnesium and aluminum in palm biodiesel: A comparative evaluation

    International Nuclear Information System (INIS)

    Chew, K.V.; Haseeb, A.S.M.A.; Masjuki, H.H.; Fazal, M.A.; Gupta, M.

    2013-01-01

    The present study aims to investigate the comparative corrosion of light-weight metals such as aluminum and magnesium in palm biodiesel. Immersion test at room temperature was carried out for each metal for 1440 h. Sample characterization techniques employed include weight loss measurement, SEM (scanning electron microscope), XRD (X-ray diffraction), TAN (total acid number) and FTIR (Fourier transform infrared spectroscopy). Results showed that the corrosion rate of magnesium was much higher compared to that of aluminum. The surface morphology revealed a significant difference between the biodiesel exposed aluminum and magnesium specimens. Upon exposure to biodiesel, the magnesium surface was found to be fully covered by gel-like sticky mass while the aluminum surface remained clean. - Highlights: • Biodiesel is highly corrosive for magnesium. • Biodiesel exposed magnesium surface showed yellowish gel-like sticky mass. • Biodiesel undergoes significant degradation upon exposure to metals

  12. Precipitation and Hardening in Magnesium Alloys

    Science.gov (United States)

    Nie, Jian-Feng

    2012-11-01

    Magnesium alloys have received an increasing interest in the past 12 years for potential applications in the automotive, aircraft, aerospace, and electronic industries. Many of these alloys are strong because of solid-state precipitates that are produced by an age-hardening process. Although some strength improvements of existing magnesium alloys have been made and some novel alloys with improved strength have been developed, the strength level that has been achieved so far is still substantially lower than that obtained in counterpart aluminum alloys. Further improvements in the alloy strength require a better understanding of the structure, morphology, orientation of precipitates, effects of precipitate morphology, and orientation on the strengthening and microstructural factors that are important in controlling the nucleation and growth of these precipitates. In this review, precipitation in most precipitation-hardenable magnesium alloys is reviewed, and its relationship with strengthening is examined. It is demonstrated that the precipitation phenomena in these alloys, especially in the very early stage of the precipitation process, are still far from being well understood, and many fundamental issues remain unsolved even after some extensive and concerted efforts made in the past 12 years. The challenges associated with precipitation hardening and age hardening are identified and discussed, and guidelines are outlined for the rational design and development of higher strength, and ultimately ultrahigh strength, magnesium alloys via precipitation hardening.

  13. Some Structural Properties of the Mixed Lead-Magnesium Hydroxyapatites

    Science.gov (United States)

    Kaaroud, K.; Ben Moussa, S.; Brigui, N.; Badraoui, B.

    2018-02-01

    Lead-magnesium hydroxyapatite solid solutions Pb(10- x)Mg x (PO4)6(OH)2 have been prepared via a hydrothermal process. They were characterized by X-ray powder diffraction, Transmission Electron Microscopy (TEM), chemical and IR spectroscopic analyses. The results of the structural refinement indicated that the limits of lead-magnesium solid solutions ( x ≤ 1.5), a regular decrease of the lattice constant a and a preferential magnesium distribution in site S(I). Through the progressive replacement of Pb2+ ( r = 0.133 nm) by the smaller cation Mg2+ ( r = 0.072 nm), all interatomic distances decrease in accordance with the decrease of the cell parameters. According to what could be expected from the coordinance of the metallic sites S(I) (hexacoordination) and S(II) (heptacoordination), the small magnesium cation preferentially occupies the four sites S(I). The results of the TEM analysis confirm the presence of magnesium in the starting solution and reveals the decrease in the average size of crystals. The IR spectra show the presence of the absorption bands characteristic for the apatite structure.

  14. Nanostructured magnesium oxide biosensing platform for cholera detection

    Science.gov (United States)

    Patel, Manoj K.; Azahar Ali, Md.; Agrawal, Ved V.; Ansari, Z. A.; Ansari, S. G.; Malhotra, B. D.

    2013-04-01

    We report fabrication of highly crystalline nanostructured magnesium oxide (NanoMgO, size >30 nm) film electrophoretically deposited onto indium-tin-oxide (ITO) glass substrate for Vibrio cholerae detection. The single stranded deoxyribonucleic acid (ssDNA) probe, consisting of 23 bases (O1 gene sequence) immobilized onto NanoMgO/ITO electrode surface, has been characterized using electrochemical, Fourier Transform-Infra Red, and UltraViolet-visible spectroscopic techniques. The hybridization studies of ssDNA/NanoMgO/ITO bioelectrode with fragmented target DNA conducted using differential pulse voltammetry reveal sensitivity as 16.80 nA/ng/cm2, response time of 3 s, linearity as 100-500 ng/μL, and stability of about 120 days.

  15. Extracellular Calcium and Magnesium in Preeclampsia and Eclampsia

    African Journals Online (AJOL)

    The cause of preeclampsia remains unknown and calcium and magnesium supplement are being suggested as means of prevention. The objective of this study was to assess magnesium and calcium in the plasma and cerebrospinal fluid of Nigerian women with preeclampsia and eclampsia. Setting was University of ...

  16. Serum magnesium is associated with the risk of dementia.

    Science.gov (United States)

    Kieboom, Brenda C T; Licher, Silvan; Wolters, Frank J; Ikram, M Kamran; Hoorn, Ewout J; Zietse, Robert; Stricker, Bruno H; Ikram, M Arfan

    2017-10-17

    To determine if serum magnesium levels are associated with the risk of all-cause dementia and Alzheimer disease. Within the prospective population-based Rotterdam Study, we measured serum magnesium levels in 9,569 participants, free from dementia at baseline (1997-2008). Participants were subsequently followed up for incident dementia, determined according to the DSM-III-R criteria, until January 1, 2015. We used Cox proportional hazard regression models to associate quintiles of serum magnesium with incident all-cause dementia. We used the third quintile as a reference group and adjusted for age, sex, Rotterdam Study cohort, educational level, cardiovascular risk factors, kidney function, comorbidities, other electrolytes, and diuretic use. Our study population had a mean age of 64.9 years and 56.6% were women. During a median follow-up of 7.8 years, 823 participants were diagnosed with all-cause dementia. Both low serum magnesium levels (≤0.79 mmol/L) and high serum magnesium levels (≥0.90 mmol/L) were associated with an increased risk of dementia (hazard ratio [HR] 1.32, 95% confidence interval [CI] 1.02-1.69, and HR 1.30, 95% CI 1.02-1.67, respectively). Both low and high serum magnesium levels are associated with an increased risk of all-cause dementia. Our results warrant replication in other population-based studies. © 2017 American Academy of Neurology.

  17. Magnesium protects cognitive functions and synaptic plasticity in streptozotocin-induced sporadic Alzheimer's model.

    Directory of Open Access Journals (Sweden)

    Zhi-Peng Xu

    Full Text Available Alzheimer's disease (AD is characterized by profound synapse loss and impairments of learning and memory. Magnesium affects many biochemical mechanisms that are vital for neuronal properties and synaptic plasticity. Recent studies have demonstrated that the serum and brain magnesium levels are decreased in AD patients; however, the exact role of magnesium in AD pathogenesis remains unclear. Here, we found that the intraperitoneal administration of magnesium sulfate increased the brain magnesium levels and protected learning and memory capacities in streptozotocin-induced sporadic AD model rats. We also found that magnesium sulfate reversed impairments in long-term potentiation (LTP, dendritic abnormalities, and the impaired recruitment of synaptic proteins. Magnesium sulfate treatment also decreased tau hyperphosphorylation by increasing the inhibitory phosphorylation of GSK-3β at serine 9, thereby increasing the activity of Akt at Ser473 and PI3K at Tyr458/199, and improving insulin sensitivity. We conclude that magnesium treatment protects cognitive function and synaptic plasticity by inhibiting GSK-3β in sporadic AD model rats, which suggests a potential role for magnesium in AD therapy.

  18. Monte Carlo wave packet approach to dissociative multiple ionization in diatomic molecules

    DEFF Research Database (Denmark)

    Leth, Henriette Astrup; Madsen, Lars Bojer; Mølmer, Klaus

    2010-01-01

    A detailed description of the Monte Carlo wave packet technique applied to dissociative multiple ionization of diatomic molecules in short intense laser pulses is presented. The Monte Carlo wave packet technique relies on the Born-Oppenheimer separation of electronic and nuclear dynamics...... and provides a consistent theoretical framework for treating simultaneously both ionization and dissociation. By simulating the detection of continuum electrons and collapsing the system onto either the neutral, singly ionized or doubly ionized states in every time step the nuclear dynamics can be solved....... The computational effort is restricted and the model is applicable to any molecular system where electronic Born-Oppenheimer curves, dipole moment functions, and ionization rates as a function of nuclear coordinates can be determined....

  19. Direct Laser Ablation and Ionization of Solids for Chemical Analysis by Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Holt, J K; Nelson, E J; Klunder, G L [Forensic Science Center, Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2007-04-15

    A laser ablation/ionization mass spectrometer system is described for the direct chemical analysis of solids. An Nd:YAG laser is used for ablation and ionization of the sample in a quadrupole ion trap operated in an ion-storage (IS) mode that is coupled with a reflectron time-of-flight mass spectrometer (TOF-MS). Single pulse experiments have demonstrated simultaneous detection of up to 14 elements present in glasses in the ppm range. However, detection of the components has produced non-stoichiometric results due to difference in ionization potentials and fractionation effects. Time-of-flight secondary ionization mass spectrometry (TOF-SIMS) was used to spatially map elemental species on the surface and provide further evidence of fractionation effects. Resolution (m/{delta}m) of 1500 and detection limits of approximately 10 pg have been achieved with a single laser pulse. The system configuration and related operating principles for accurately measuring low concentrations of isotopes are described.

  20. Protein profiling of single epidermal cell types from Arabidopsis thaliana using surface-enhanced laser desorption and ionization technology.

    Science.gov (United States)

    Ebert, Berit; Melle, Christian; Lieckfeldt, Elke; Zöller, Daniela; von Eggeling, Ferdinand; Fisahn, Joachim

    2008-08-25

    Here, we describe a novel approach for investigating differential protein expression within three epidermal cell types. In particular, 3000 single pavement, basal, and trichome cells from leaves of Arabidopsis thaliana were harvested by glass micro-capillaries. Subsequently, these single cell samples were joined to form pools of 100 individual cells and analyzed using the ProteinChip technology; SELDI: surface-enhanced laser desorption and ionization. As a result, numerous protein signals that were differentially expressed in the three epidermal cell types could be detected. One of these proteins was characterized by tryptical digestion and subsequent identification via tandem quadrupole-time of flight (Q-TOF) mass spectrometry. Down regulation of this sequenced small subunit precursor of ribulose-1,5 bisphosphate carboxylase(C) oxygenase(O) (RuBisCo) in trichome and basal cells indicates the sink status of these cell types that are located on the surface of A. thaliana source leaves. Based on the obtained protein profiles, we suggest a close functional relationship between basal and trichome cells at the protein level.

  1. EPR and optical studies of Cu2+ ions doped in magnesium potassium phosphate hexahydrate single crystals

    International Nuclear Information System (INIS)

    Kripal, Ram; Shukla, Santwana

    2011-01-01

    An electron paramagnetic resonance (EPR) study of Cu 2+ -doped magnesium potassium phosphate is performed at liquid nitrogen temperature (LNT; 77 K). Two magnetically non-equivalent sites for Cu 2+ are observed. The spin Hamiltonian parameters are determined with the fitting of spectra to a rhombic symmetry crystalline field. The ground state wavefunction is also determined. The g-anisotropy is evaluated and compared with the experimental value. With the help of an optical study, the nature of the bonding in the complex is discussed.

  2. Parallel nano-assembling of a multifunctional GO/HapNP coating on ultrahigh-purity magnesium for biodegradable implants

    Science.gov (United States)

    Santos, C.; Piedade, C.; Uggowitzer, P. J.; Montemor, M. F.; Carmezim, M. J.

    2015-08-01

    This work reports the one-step fabrication of a novel coating on ultra high purity magnesium using a parallel nano assembling process. The multifunctional biodegradable surface was obtained by adding hydroxyapatite nanoparticles (HapNP) plus graphene oxide (GO). The coating was characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray diffractometer (XRD), micro-Raman spectroscopy. The thin phosphate coating (thickness of 1 μm) reveals a uniform coverage with cypress like structures. The incorporation of HapNP and GO promotes the hydrophilic behavior of the coating surface. The results revealed that the proposed coating can be used to tailor the surface properties such as wettability by adjusting the contents of HapNP and GO. The in vitro degradation rate of the coated magnesium suggests that the presence of HapNP and GO/HapNP in the phosphate coating decreased the current density compared to the single phosphate coating and uncoated magnesium. This study also reveals the HapNP/GO/phosphate coating induces apatite formation, showing suitable degradability that makes it a promising coating candidate for enhanced bone regeneration.

  3. Electron emission from transfer ionization reaction in 30 keV amu‑1 He 2+ on Ar collision

    Science.gov (United States)

    Amaya-Tapia, A.; Antillón, A.; Estrada, C. D.

    2018-06-01

    A model is presented that describes the transfer ionization process in H{e}2++Ar collision at a projectile energy of 30 keV amu‑1. It is based on a semiclassical independent-particle close-coupling method that yields a reasonable agreement between calculated and experimental values of the total single-ionization and single-capture cross sections. It is found that the transfer ionization reaction is predominantly carried out through simultaneous capture and ionization, rather than by sequential processes. The transfer-ionization differential cross section in energy that is obtained satisfactorily reproduces the global behavior of the experimental data. Additionally, the probabilities of capture and ionization as function of the impact parameter for H{e}2++A{r}+ and H{e}++A{r}+ collisions are calculated, as far as we know, for the first time. The results suggest that the model captures essential elements that describe the two-electron transfer ionization process and could be applied to systems and processes of two electrons.

  4. Preparation of magnesium metal matrix composites by powder metallurgy process

    Science.gov (United States)

    Satish, J.; Satish, K. G., Dr.

    2018-02-01

    Magnesium is the lightest metal used as the source for constructional alloys. Today Magnesium based metal matrix composites are widely used in aerospace, structural, oceanic and automobile applications for its light weight, low density(two thirds that of aluminium), good high temperature mechanical properties and good to excellent corrosion resistance. The reason of designing metal matrix composite is to put in the attractive attributes of metals and ceramics to the base metal. In this study magnesium metal matrix hybrid composite are developed by reinforcing pure magnesium with silicon carbide (SiC) and aluminium oxide by method of powder metallurgy. This method is less expensive and very efficient. The Hardness test was performed on the specimens prepared by powder metallurgy method. The results revealed that the micro hardness of composites was increased with the addition of silicon carbide and alumina particles in magnesium metal matrix composites.

  5. Blood triggered corrosion of magnesium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Geis-Gerstorfer, J., E-mail: juergen.geis-gerstorfer@uni-tuebingen.de [Section Medical Materials and Technology, University Hospital Tuebingen, Tuebingen (Germany); Schille, Ch.; Schweizer, E.; Rupp, F.; Scheideler, L. [Section Medical Materials and Technology, University Hospital Tuebingen, Tuebingen (Germany); Reichel, H.-P. [Weisensee Company, Eichenzell (Germany); Hort, N. [GKSS Research Center, Institute of Materials Research, Geesthacht (Germany); Nolte, A.; Wendel, H.-P. [Div. Congenital and Paediatric Cardiac Surgery, University Children' s Hospital, Tuebingen (Germany)

    2011-12-15

    Intravascular stents manufactured out of bioabsorbable magnesium (Mg) or Mg-alloys are considered as auspicious candidates for the next stent generation. However, before clinical application numerous physical and biological tests, especially to predict the clinically highly important degradation kinetics in vivo, have to be performed. In a Chandler-Loop model, the initial degradation of eight different magnesium alloys during 6 h in contact with human whole blood was investigated. The magnesium release varied between 0.91 {+-} 0.33 mg/cm{sup 2} (MgAl9Zn1) and 2.57 {+-} 0.38 mg/cm{sup 2} (MgZn1). No correlation could be found with Mg release data obtained after immersion in simulated body fluid (SBF). This pilot study showed that Mg corrosion is highly influenced by the biological test environment (SBF or blood, etc.) and that a modified Chandler-Loop model with human whole blood may be superior to predict corrosion of Mg alloys under clinical conditions than the SBF models presently used.

  6. Research on A3 steel corrosion behavior of basic magnesium sulfate cement

    Science.gov (United States)

    Xing, Sainan; Wu, Chengyou; Yu, Hongfa; Jiang, Ningshan; Zhang, Wuyu

    2017-11-01

    In this paper, Tafel polarization technique is used to study the corrosion behavior of A3 steel basic magnesium sulfate, and then analyzing the ratio of raw materials cement, nitrites rust inhibitor and wet-dry cycle of basic magnesium sulfate corrosion of reinforced influence, and the steel corrosion behavior of basic magnesium sulfate compared with magnesium oxychloride cement and Portland cement. The results show that: the higher MgO/MgSO4 mole ratio will reduce the corrosion rate of steel; Too high and too low H2O/MgSO4 mole ratio may speed up the reinforcement corrosion effect; Adding a small amount of nitrite rust and corrosion inhibitor, not only can obviously reduce the alkali type magnesium sulfate in the early hydration of cement steel bar corrosion rate, but also can significantly reduce dry-wet circulation under the action of alkali type magnesium sulfate cement corrosion of reinforcement effect. Basic magnesium sulfate cement has excellent ability to protect reinforced, its long-term corrosion of reinforcement effect and was equal to that of Portland cement. Basic magnesium sulfate corrosion of reinforced is far below the level in the MOC in the case.

  7. The ionizing radiation of Seyfert 2 galactic nuclei

    Science.gov (United States)

    Ho, Luis C.; Shields, Joseph C.; Filippenko, Alexei V.

    1993-01-01

    We report the discovery of a nonrandom trend in the dispersion of emission-line intensity ratios for Seyfert 2 galaxies. The sense of this pattern suggests the influence of a single physical parameter, the hardness of the ionizing continuum, which controls the heating energy per ionizing photon. We compare the observed line ratios with new photoionization calculations and find that the observed distributions can be reproduced if the ionizing continuum is parametrized by a power law. Our results also suggest an inverse correlation between luminosity and continuum hardness for Seyfert 2 nuclei; if true, this trend extends a similar pattern known in quasars and Seyfert 1 galaxies to active galactic nuclei of lower luminosity. Samples of Seyfert 2 nuclei with improved selection uniformity are desirable for elaboration of these findings.

  8. Magnesium-made door frame for passenger cars; Pkw-Tuerrahmen aus Magnesium

    Energy Technology Data Exchange (ETDEWEB)

    Tikal, F.; Vollmer, C. [Kassel Univ. (Gesamthochschule) (Germany). Inst. fuer Produktionstechnik und Logistik

    1997-11-01

    One of the most complicated parts of a car is the door. An so it will be in the future. More and more parts will be integrated in a car`s door, especially safety and comfort related parts as well as a big number of functional elements. The car industry tries intensively to bring about a growing safety image to its buyers. At the Institute for Technical Production and Logistics (IPL) of the University of Kassel (GhK) a passenger door construction out of magnesium has been developed on the base of a foregoing construction. With the new practice orientated model the time of production could be essentially reduced while at the same time the weight could be decreased. (orig.) [Deutsch] Am Institut fuer Produktionstechnik und Logistik (ipl) der Universitaet Gesamthochschule Kassel wurde ein optimierter Magnesium-Druckguss-Rahmen fuer eine Pkw-Tuer, basierend auf einer vorangegangenen Arbeit, entwickelt. Mit dem neuen praxisnahen Modell konnte die Montagezeit erheblich reduziert und Gewicht eingespart werden. (orig.)

  9. Charge transfer and ionization occurring in proton- and helium ion-atom collisions

    International Nuclear Information System (INIS)

    DuBois, R.D.

    1985-12-01

    Two examples are presented where specific channels have been identified that are responsible for single and double target ionization via direct coulomb ionization or charge transfer processes. Using ratios of absolute cross sections that have been measured for these processes it was shown that an independent electron model should be appropriate for calculating direct double target ionization but generally appears to be inadequate in calculating charge transfer plus ionization and double charge transfer cross sections. At present such detailed information can be obtained only in limited cases. However cross sections with detailed final charge state information should provide stringent tests for present and future theoretical work. 22 refs., 2 figs

  10. Deformation behaviour of a new magnesium ternary alloy

    Science.gov (United States)

    Guglielmi, P.; Kaya, A. Arslan; Sorgente, D.; Palumbo, G.

    2018-05-01

    Magnesium based alloys are yet to fill a greater niche especially in the automotive and aeronautical industry. In fact, such alloys have a big weight saving potential, together with good damping characteristics. However, nowadays about 90% of Magnesium products are produced by casting, mainly using two alloy systems, namely Mg-Al-Zn (AZ91D) and Mg-Al (AM50, AM60). Now the emphasis, especially after having achieved considerable success in creep resistance and understanding of the deformation behaviour of Magnesium, has been shifted towards wrought alloys; AZ31, in this case, is the most popular. In this work a multi-element Magnesium alloy, developed to improve the deformation capacity of such a lightweight material, has been investigated and compared to a commercial AZ31B. The possibility of adopting such a multi-element Magnesium alloy for manufacturing components via unconventional sheet forming (such as superplastic forming, warm hydroforming, incremental forming) has been proved in the present work focusing the attention on the superplastic field. Free inflation tests were thus conducted at 450°C setting constant pressure to investigate the superplastic behaviour (in terms of dome height and strain rate sensitivity index) of both the multi-element Magnesium alloy (Mg-2Zn-Ce) and the commercial one (AZ31B). To enhance information on the thickness distribution and investigate the microstructure evolution, metallographic analyses on the samples used to carry out free inflation tests were also performed. The developed ternary alloy manifested quite a good deformation behaviour (high strain rate sensitivity index), even being tested in the as cast condition; in addition a limited grain coarsening was observed in the specimens after deformation.

  11. Study of the influence of adsorption of oxygen, hydrogen and water on radiation-induced thermally activated currents of magnesium oxide

    International Nuclear Information System (INIS)

    Wysocki, S.

    1985-01-01

    Recently, radiation-induced thermally activated currents (RITAC) have been studied in purified and magnesium-doped lithium fluoride. In the RITAC method, the electric field is applied at low temperature, only during irradiation. The present paper deals with the dipolar complexes generated by γ-radiations in the surface region of magnesium oxide in vacuum and in the presence of oxygen, hydrogen and water. Spectrally pure MgO single crystal spectrally pure oxygen and hydrogen and doubly distilled water were used. The electrodes were deposited on the (100) surface of MgO single crystal by vacuum evaporation of gold. Experimental details are given. A figure shows the thermally activated depolarization (TAD) curve for MgO in vacuum. In a TAD experiment, the sample was subjected to a constant electric field at 700 K and cooled. Upon reaching room temperature the electric field was removed In this case we observed a single peak at Tsub(max) = 511 K. A figure shows RITAC curves for an MgO sample in vacuum after irradiation. The results are shown and discussed. (author)

  12. Synthesis of nanocrystalline magnesium nitride (Mg3N2) powder using thermal plasma

    International Nuclear Information System (INIS)

    Kim, Dong-Wook; Kim, Tae-Hee; Park, Hyun-Woo; Park, Dong-Wha

    2011-01-01

    Nanocrystalline magnesium nitride (Mg 3 N 2 ) powder was synthesized from bulk magnesium by thermal plasma at atmospheric pressure. Magnesium vapor was generated through heating the bulk magnesium by DC plasma jet and reacted with ammonia gas. Injecting position and flow rates of ammonia gas were controlled to investigate an ideal condition for Mg 3 N 2 synthesis. The synthesized Mg 3 N 2 was cooled and collected on the chamber wall. Characteristics of the synthesized powders for each experimental condition were analyzed by X-ray diffractometer (XRD), scanning electron microscopy (SEM) and thermogravity analysis (TGA). In absence of NH 3 , magnesium metal powder was formed. The synthesis with NH 3 injection in low temperature region resulted in a formation of crystalline magnesium nitride with trigonal morphology, whereas the mixture of magnesium metal and amorphous Mg 3 N 2 was formed when NH 3 was injected in high temperature region. Also, vaporization process of magnesium was discussed.

  13. THE FORMING OF MAGNESIUM ALLOY FORGINGS FOR AIRCRAFT AND AUTOMOTIVE APPLICATIONS

    Directory of Open Access Journals (Sweden)

    Anna Dziubińska

    2016-09-01

    Full Text Available The paper presents the theoretical and technological aspects of forming magnesium alloy parts for aircraft and automotive applications. The main applications of magnesium alloys in the aircraft and automotive industries are discussed. In addition, the forging technology for magnesium alloys is generally described, with a particular emphasis on wrought alloys. A brief outline of the state of the art in the forging of magnesium alloys is given based on a survey of the specialist literature and the results of previous research by the authors.

  14. Lithium-aluminum-magnesium electrode composition

    Science.gov (United States)

    Melendres, Carlos A.; Siegel, Stanley

    1978-01-01

    A negative electrode composition is presented for use in a secondary, high-temperature electrochemical cell. The cell also includes a molten salt electrolyte of alkali metal halides or alkaline earth metal halides and a positive electrode including a chalcogen or a metal chalcogenide as the active electrode material. The negative electrode composition includes up to 50 atom percent lithium as the active electrode constituent and a magnesium-aluminum alloy as a structural matrix. Various binary and ternary intermetallic phases of lithium, magnesium, and aluminum are formed but the electrode composition in both its charged and discharged state remains substantially free of the alpha lithium-aluminum phase and exhibits good structural integrity.

  15. Higher Magnesium Intake Is Associated with Lower Fasting Glucose and Insulin, with No Evidence of Interaction with Select Genetic Loci, in a Meta-Analysis of 15 CHARGE Consortium Studies1234

    Science.gov (United States)

    Hruby, Adela; Ngwa, Julius S.; Renström, Frida; Wojczynski, Mary K.; Ganna, Andrea; Hallmans, Göran; Houston, Denise K.; Jacques, Paul F.; Kanoni, Stavroula; Lehtimäki, Terho; Lemaitre, Rozenn N.; Manichaikul, Ani; North, Kari E.; Ntalla, Ioanna; Sonestedt, Emily; Tanaka, Toshiko; van Rooij, Frank J. A.; Bandinelli, Stefania; Djoussé, Luc; Grigoriou, Efi; Johansson, Ingegerd; Lohman, Kurt K.; Pankow, James S.; Raitakari, Olli T.; Riserus, Ulf; Yannakoulia, Mary; Zillikens, M. Carola; Hassanali, Neelam; Liu, Yongmei; Mozaffarian, Dariush; Papoutsakis, Constantina; Syvänen, Ann-Christine; Uitterlinden, André G.; Viikari, Jorma; Groves, Christopher J.; Hofman, Albert; Lind, Lars; McCarthy, Mark I.; Mikkilä, Vera; Mukamal, Kenneth; Franco, Oscar H.; Borecki, Ingrid B.; Cupples, L. Adrienne; Dedoussis, George V.; Ferrucci, Luigi; Hu, Frank B.; Ingelsson, Erik; Kähönen, Mika; Kao, W. H. Linda; Kritchevsky, Stephen B.; Orho-Melander, Marju; Prokopenko, Inga; Rotter, Jerome I.; Siscovick, David S.; Witteman, Jacqueline C. M.; Franks, Paul W.; Meigs, James B.; McKeown, Nicola M.; Nettleton, Jennifer A.

    2013-01-01

    Favorable associations between magnesium intake and glycemic traits, such as fasting glucose and insulin, are observed in observational and clinical studies, but whether genetic variation affects these associations is largely unknown. We hypothesized that single nucleotide polymorphisms (SNPs) associated with either glycemic traits or magnesium metabolism affect the association between magnesium intake and fasting glucose and insulin. Fifteen studies from the CHARGE (Cohorts for Heart and Aging Research in Genomic Epidemiology) Consortium provided data from up to 52,684 participants of European descent without known diabetes. In fixed-effects meta-analyses, we quantified 1) cross-sectional associations of dietary magnesium intake with fasting glucose (mmol/L) and insulin (ln-pmol/L) and 2) interactions between magnesium intake and SNPs related to fasting glucose (16 SNPs), insulin (2 SNPs), or magnesium (8 SNPs) on fasting glucose and insulin. After adjustment for age, sex, energy intake, BMI, and behavioral risk factors, magnesium (per 50-mg/d increment) was inversely associated with fasting glucose [β = −0.009 mmol/L (95% CI: −0.013, −0.005), P magnesium-related SNP or interaction between any SNP and magnesium reached significance after correction for multiple testing. However, rs2274924 in magnesium transporter-encoding TRPM6 showed a nominal association (uncorrected P = 0.03) with glucose, and rs11558471 in SLC30A8 and rs3740393 near CNNM2 showed a nominal interaction (uncorrected, both P = 0.02) with magnesium on glucose. Consistent with other studies, a higher magnesium intake was associated with lower fasting glucose and insulin. Nominal evidence of TRPM6 influence and magnesium interaction with select loci suggests that further investigation is warranted. PMID:23343670

  16. Design of the Intravenous Magnesium Efficacy in Acute Stroke (IMAGES trial [ISRCTN19943732

    Directory of Open Access Journals (Sweden)

    Lees Kennedy

    2000-12-01

    Full Text Available Abstract The Intravenous Magnesium Efficacy in Acute Stroke (IMAGES trial is a multicentre,randomised, placebo-controlled trial of magnesium sulphate (MgSO4 funded by the UK Medical Research Council. When complete, it will be the largest single neuroprotective study undertaken to date. Conscious patients presenting within 12 h of acute stroke with limb weakness are eligible. The primary outcome measure is combined death and disability as measured using the Barthel Index at 90-day follow up. By randomizing 2700 patients, the study will have 84% power to detect a 5.5% absolute reduction in the primary end-point. By April 2000, 86 centres were participating, with representation in Canada, USA, Europe, South America, Singapore and Australia. So far, 1206 patients have been randomised, of whom 37% were treated within 6 h. Overall 3-month mortality was 20% and the primary outcome event rate was 43%. The study is ongoing and centres worldwide are encouraged to participate.

  17. Magnesium and uranium ignition in different gaseous atmospheres

    International Nuclear Information System (INIS)

    Darras, R.; Baque, P.; Leclercq, D.

    1960-01-01

    Magnesium, uranium and some of their alloys burning temperatures have been systematically determined in an air or carbon dioxide atmosphere, either dry or wet. Two different ways of heating have been used: either continuously rising up the temperature, or heating to and then maintaining a constant temperature. The results are clearly different in the two cases. Besides, if moisture has little effect on the magnesium burning temperatures in air, it does lower them by about 130-140 deg. C in CO 2 . The differences of sight between the burning of magnesium and uranium have been noticed; this leads to distinguish between an 'ignition' and an 'inflammation'. (author) [fr

  18. Recent research and developments on wrought magnesium alloys

    Directory of Open Access Journals (Sweden)

    Sihang You

    2017-09-01

    Full Text Available Wrought magnesium alloys attract special interests as lightweight structural material due to their homogeneous microstructure and enhanced mechanical properties compared to as-cast alloys. In this contribution, recent research and developments on wrought magnesium alloys are reviewed from the viewpoint of the alloy design, focusing on Mg-Al, Mg-Zn and Mg-rare earth (RE systems. The effects of different alloying elements on the microstructure and mechanical properties are described considering their strengthening mechanisms, e.g. grain refinement, precipitation and texture hardening effect. Finally, the new alloy design and also the future research of wrought magnesium alloys to improve their mechanical properties are discussed.

  19. New technology for the production of magnesium strips and sheets

    Directory of Open Access Journals (Sweden)

    R. Kawalla

    2008-07-01

    Full Text Available A new production technology for magnesium strip, based on twin-roll-casting and strip rolling was developed in Freiberg Germany. By means of this economic method it is possible to produce strips in deep drawing quality with good forming properties in order to satisfy the request for low cost Mg sheets in the automotive and electronic industry. Both, coils as single sheets, were manufactured and rolled to a thickness of 1mm(0,5 mm. The technology of the new process and the properties of the twin-roll-casted material and the final sheets are presented.

  20. Research of Plasma Spraying Process on Aluminum-Magnesium Alloy

    Directory of Open Access Journals (Sweden)

    Patricija Kavaliauskaitė

    2016-04-01

    Full Text Available The article examines plasma sprayed 95Ni-5Al coatings on alu-minum-magnesium (Mg ≈ 2,6‒3,6 % alloy substrate. Alumi-num-magnesium samples prior spraying were prepared with mechanical treatment (blasting with Al2O3. 95Ni-5Al coatings on aluminum-magnesium alloys were sprayed with different parameters of process and coating‘s thickness, porosity, micro-hardness and microstructure were evaluated. Also numerical simulations in electric and magnetic phenomena of plasma spray-ing were carried out.

  1. Plasma Magnesium and the Risk of Ischemic Stroke among Women

    Science.gov (United States)

    Akarolo-Anthony, Sally N.; Jiménez, Monik C.; Chiuve, Stephanie E.; Spiegelman, Donna; Willett, Walter C.; Rexrode, Kathryn M.

    2014-01-01

    Background and Purpose Lower plasma magnesium levels may be associated with higher blood pressure and endothelial dysfunction, but sparse prospective data are available for stroke. Methods Among 32,826 participants in the Nurses’ Health Study who provided blood samples in 1989–1990, incident ischemic strokes were identified and confirmed by medical records through 2006. We conducted a nested case-control analysis of 459 cases, matched 1:1 to controls on age, race/ethnicity, smoking status, date of blood draw, fasting status, menopausal status and hormone use. We used conditional logistic regression models to estimate the multivariable adjusted association of plasma magnesium and the risk of ischemic stroke and ischemic stroke subtypes. Results Median magnesium levels did not differ between ischemic stroke cases and controls (median=0.86 mmol/l for both; p-value=0.14). Conditional on matching factors, women in the lowest magnesium quintile had a relative risk (RR) of 1.34 (95% confidence interval [CI]: 0.86–2.10, p trend=0.13) for total ischemic stroke, compared to women in the highest quintile. Additional adjustment for risk factors and confounders did not substantially alter the risk estimates for total ischemic stroke. Women with magnesium levels magnesium levels ≥0.82 mmol/l. No significant effect modification was observed by age, body mass index, hypertension or diabetes. Conclusions Lower plasma magnesium levels may contribute to higher risk of ischemic stroke among women. PMID:25116874

  2. Laser-enhanced ionization spectroscopy around the ionization limit

    International Nuclear Information System (INIS)

    Axner, O.; Berglind, T.; Sjoestroem, S.

    1986-01-01

    Laser-induced photoionization and Laser-Enhanced collision Ionization (LEI) of Na, Tl, and Li in flames are detected by measuring the production of charges following a laser excitation. The ionization signal is investigated for excitations of the atoms from lower lying states both to Rydberg states close to the ionization limit, as well as to continuum states, i.e. the process of collision ionization is compared with that of photoionization. The qualitative behaviour of the ionization signal when scanning across the ionization limit is studied. It is shown that the ionization signal has a smooth behaviour when passing from bound states into continuum states. The laser-induced photoionization signal strength of atoms in flames is both calculated and measured and a good agreement is obtained. A calculation of wavelength dependent photoionization signal strengths for a number of elements is also presented. Photoionization is used to determine flame- and geometry-dependent parameters. An implication of photoionization in connection with LEI spectrometry for trace element analysis is that there will be a significant increase in background noise if the sample contains high concentrations of easily photoionizing elements and short wavelength light is used. (orig.)

  3. Contribution of stable isotopes to the study of pharmacokinetics of magnesium salts; Apport des isotopes stables a l'etude de la pharmacocinetique de sels de magnesium

    Energy Technology Data Exchange (ETDEWEB)

    Benech, H

    1999-05-28

    The use of stable isotopes as labels is becoming an attractive tool for the study of magnesium behavior in humans. It has been used two stable isotopes of magnesium, {sup 25}Mg and {sup 26}Mg, to measure the absolute bioavailability of a pharmaceutical form of magnesium. (N.C.)

  4. Ionization versus indirect effects of ionizing radiation on cellular DNA

    International Nuclear Information System (INIS)

    Cadet, Jean; Ravanat, Jean-Luc; Douki, Thierry

    2012-01-01

    Emphasis has been placed in the last decade on the elucidation of the main degradation pathways of isolated DNA mediated by hydroxyl radical (OH) and one-electron oxidation reactions as the result of indirect and direct effects of ionizing radiation respectively. This has led to the isolation and characterization of about 100 oxidized purine and pyrimidine nucleosides if hydroperoxide precursors and diastereomers are included. However, far less information is available on the mechanisms of radiation-induced degradation of bases in cellular DNA mostly due partly to analytical difficulties. It may be reminded that the measurement of oxidized nucleosides and bases in nuclear DNA is still a challenging issue which until recently has been hampered by the use of inappropriate methods such as the GC-MS that have led to overestimated values of the lesions by factors varying between two and three orders of magnitude. At the present, using the accurate and sensitive HPLC/MS/MS assay, 11 single modified nucleosides and bases were found to be generated in cellular DNA upon exposure to gamma rays and heavy ions. This validates several of the OH-mediated oxidation pathways of thymine, guanine and adenine that were previously inferred from model studies. The concomitant decrease in the yields of oxidized bases with the increase in the LET of heavy ions is accounted for by the preponderance of indirect effects in the damaging action of ionizing radiation on DNA. Further evidence for the major role played by .OH was provided by the results of exposure of cells to high intensity 266 nm laser pulses. Under these conditions 8-oxo-7,8-dihydroguanine is mostly produced by biphotonic ionization of DNA nucleobases and subsequent hole migration to guanine bases. It is likely that some of the oxidized bases that have been isolated as single lesions are in fact involved in clustered damage. Interestingly it was recently shown that a single oxidation hit is capable of generating complex

  5. Determination of calcium and magnesium in nuclear grade alumina by ion chromatography technique

    International Nuclear Information System (INIS)

    Hespanhol, E.C.B.; Pires, M.A.F.; Atalla, L.T.

    1987-07-01

    A simple method for solubilization of alumina and separation of magnesium and calcium from alumina matrix was developed by initial coprecipitation of those elements with iron(III) hydroxide. Calcium and magnesium were later separated from iron chloride anionic complex in a Dowex 1-X 10 anionic exchange resin. The ion chromatography tecnnique was employed for the analysis of calcium and magnesium. One hundred percent recovery for calcium and magnesium was obtained in their separation from alumina. A precision of 6% and 10% for magnesium and calcium, respectively, was obtained in alumina samples analysis which contain less than 0,02% of magnesium and less than 0,08% of calcium. (Author) [pt

  6. The yield, processing, and biological consequences of clustered DNA damage induced by ionizing radiation

    International Nuclear Information System (INIS)

    Shikazono, Naoya; Noguchi, Miho; Fujii, Kentaro; Urushibara, Ayumi; Yokoya, Akinari

    2009-01-01

    After living cells are exposed to ionizing radiation, a variety of chemical modifications of DNA are induced either directly by ionization of DNA or indirectly through interactions with water-derived radicals. The DNA lesions include single strand breaks (SSB), base lesions, sugar damage, and apurinic/apyrimidinic sites (AP sites). Clustered DNA damage, which is defined as two or more of such lesions within one to two helical turns of DNA induced by a single radiation track, is considered to be a unique feature of ionizing radiation. A double strand break (DSB) is a type of clustered DNA damage, in which single strand breaks are formed on opposite strands in close proximity. Formation and repair of DSBs have been studied in great detail over the years as they have been linked to important biological endpoints, such as cell death, loss of genetic material, chromosome aberration. Although non-DSB clustered DNA damage has received less attention, there is growing evidence of its biological significance. This review focuses on the current understanding of (1) the yield of non-DSB clustered damage induced by ionizing radiation (2) the processing, and (3) biological consequences of non-DSB clustered DNA damage. (author)

  7. Effectivness of dexametasone vs. Magnesium sulphate in postoperative analgesia: Dexametasone vs. Magnesium sulphate

    Directory of Open Access Journals (Sweden)

    Dautaj Brikena

    2016-01-01

    Full Text Available Introduction: Preoperative use of additive substances may be very helpful in perioperative acute pain management. Intravenous administration of dexametasone in preoperative period prevents postoperative nausea and vomiting but also provides better pain relief. It is also well known that magnesium sulphate (the NMDA receptor's antagonist by its central mechanism of action may be effective in postoperative pain control. Aim: The purpose of this study was to evaluate the effect of dexametasone and magnesium sulphate on postoperative pain management in patients undergoing abdominal surgery (open cholecystectomy. Methods: Seventy eight patients scheduled for elective surgery (open cholecystectomy were included in this study. This was the prospective cohort randomized placebo- controlled study. A total of 78 patients were randomized into three groups. Each group had twenty six patients. The group D, received dexametasone 0.1 mg/ kg iv 30 minutes before surgery. The group M received magnesium sulphate 3 mg/kg iv 30 minutes before surgery. The third group S was placebo group and patients in this group received saline in the same volume for each patient. For pain control after surgery all patients received tramadol 0.9-1.2 mg/kg and diklophenac 1.76 mg/kg. When necessary (VAS ≥ 7, morphine sulphate in dose 0.15 mg/kg was administred subcutaneously For treatment of emetic episodes metoclopramid 10 mg iv. was used. The patients were observed for intensity of pain measured VAS 0-10, pain relief and satisfaction with therapy, sedation, adverse events, emetic episodes and hemodynamic parameters. Results: There was no difference between groups regarding demographic data (age, gender, body weight, ASA score, comorbidity, duration of surgery and anesthesia and amount of fentanyl received during surgery. In group D 11.54% of patients received additional analgesia (morphine sulphate 0.15 mg/kg sc in the first 4 hours and 27% of patients in the first 24 hours

  8. Magnesium prevents vascular calcification in vitro by inhibition of hydroxyapatite crystal formation.

    NARCIS (Netherlands)

    Braake, A.D. ter; Tinnemans, P.T.; Shanahan, C.M.; Hoenderop, J.G.J.; Baaij, J.H.F. de

    2018-01-01

    Magnesium has been shown to effectively prevent vascular calcification associated with chronic kidney disease. Magnesium has been hypothesized to prevent the upregulation of osteoblastic genes that potentially drives calcification. However, extracellular effects of magnesium on hydroxyapatite

  9. Ghost peaks observed after atmospheric pressure matrix-assisted laser desorption/ionization experiments may disclose new ionization mechanism of matrix-assisted hypersonic velocity impact ionization.

    Science.gov (United States)

    Moskovets, Eugene

    2015-08-30

    Understanding the mechanisms of matrix-assisted laser desorption/ionization (MALDI) promises improvements in the sensitivity and specificity of many established applications in the field of mass spectrometry. This paper reports a serendipitous observation of a significant ion yield in a post-ionization experiment conducted after the sample had been removed from a standard atmospheric pressure (AP)-MALDI source. This post-ionization is interpreted in terms of collisions of microparticles moving with a hypersonic velocity into a solid surface. Calculations show that the thermal energy released during such collisions is close to that absorbed by the top matrix layer in traditional MALDI. The microparticles, containing both the matrix and analytes, could be detached from a film produced inside the inlet capillary during the sample ablation and accelerated by the flow rushing through the capillary. These observations contribute some new perspective to ion formation in both laser and laser-less matrix-assisted ionization. An AP-MALDI ion source hyphenated with a three-stage high-pressure ion funnel system was utilized for peptide mass analysis. After the laser had been turned off and the MALDI sample removed, ions were detected during a gradual reduction of the background pressure in the first funnel. The constant-rate pressure reduction led to the reproducible appearance of different singly and doubly charged peptide peaks in mass spectra taken a few seconds after the end of the MALDI analysis of a dried-droplet spot. The ion yield as well as the mass range of ions observed with a significant delay after a completion of the primary MALDI analysis depended primarily on the background pressure inside the first funnel. The production of ions in this post-ionization step was exclusively observed during the pressure drop. A lower matrix background and significant increase in relative yield of double-protonated ions are reported. The observations were partially consistent

  10. Mechanistic origin and prediction of enhanced ductility in magnesium alloys

    Science.gov (United States)

    Wu, Zhaoxuan; Ahmad, Rasool; Yin, Binglun; Sandlöbes, Stefanie; Curtin, W. A.

    2018-01-01

    Development of ductile magnesium alloys is key to their use in reducing the weight of vehicles and other applications. Wu et al. tackle this issue by determining the underlying mechanisms in unprocessed magnesium alloys. Dilute amounts of solutes enhanced certain ductility-improving mechanisms over ones that cause brittle fracture. From this, the authors developed a theory that may be helpful for screening the large number of potential magnesium alloy compositions.

  11. Magnesium and metabolic syndrome: The role of magnesium in health and disease

    Science.gov (United States)

    Metabolic syndrome is a constellation of conditions associated with elevated risk of diabetes and cardiovascular disease. Magnesium, the fourth most abundant cation in the human body and required in over 300 enzymatic reactions, has been shown in experimental, observational, and clinical studies to ...

  12. [Ionizing and non-ionizing radiation (comparative risk estimations)].

    Science.gov (United States)

    Grigor'ev, Iu G

    2012-01-01

    The population has widely used mobile communication for already more than 15 years. It is important to note that the use of mobile communication has sharply changed the conditions of daily exposure of the population to EME We expose our brain daily for the first time in the entire civilization. The mobile phone is an open and uncontrollable source of electromagnetic radiation. The comparative risk estimation for the population of ionizing and non-ionizing radiation was carried out taking into account the real conditions of influence. Comparison of risks for the population of ionizing and non-ionizing radiation leads us to a conclusion that EMF RF exposure in conditions of wide use of mobile communication is potentially more harmful than ionizing radiation influence.

  13. Enzymatic, urease-mediated mineralization of gellan gum hydrogel with calcium carbonate, magnesium-enriched calcium carbonate and magnesium carbonate for bone regeneration applications

    DEFF Research Database (Denmark)

    Douglas, Timothy E L; Łapa, Agata; Samal, Sangram Keshari

    2017-01-01

    enzymatically with CaCO3 , Mg-enriched CaCO3 and magnesium carbonate to generate composite biomaterials for bone regeneration. Hydrogels loaded with the enzyme urease were mineralized by incubation in mineralization media containing urea and different ratios of calcium and magnesium ions. Increasing...

  14. Suppression of exercise-induced angina by magnesium sulfate in patients with variant angina

    International Nuclear Information System (INIS)

    Kugiyama, K.; Yasue, H.; Okumura, K.

    1988-01-01

    The effects of intravenous magnesium on exercise-induced angina were examined in 15 patients with variant angina and in 13 patients with stable effort angina and were compared with those of placebo. Symptom-limited bicycle exercise and thallium-201 myocardial scintigraphy were performed after intravenous administration of 0.27 mmol/kg body weight of magnesium sulfate and after placebo on different days. In all patients, serum magnesium levels after administration of magnesium sulfate were about twofold higher than levels after placebo. Exercise-induced angina associated with transient ST segment elevation occurred in 11 patients with variant angina receiving placebo and in only 2 of these patients receiving magnesium (p less than 0.005). On the other hand, exercise-induced angina was not suppressed by magnesium in any patient with stable effort angina. In these patients there was no significant difference in exercise duration after administration of placebo versus after administration of magnesium. The size of the perfusion defect as measured by thallium-201 scintigraphy was significantly less in patients with variant angina receiving magnesium than that in those receiving placebo (p less than 0.001), whereas it was not significantly different in patients with stable effort angina receiving placebo versus magnesium. In conclusion, exercise-induced angina is suppressed by intravenous magnesium in patients with variant angina but not in patients with stable effort angina. This beneficial effect of magnesium in patients with variant angina is most likely due to improvement of regional myocardial blood flow by suppression of coronary artery spasm

  15. Effects of magnesium sulfate on the foliar absorption of phosphates at the pumpkin; Effets du sulfate de magnesium sur l'absorption foliaire de phosphates chez le potiron

    Energy Technology Data Exchange (ETDEWEB)

    Chamel, A

    1962-07-01

    The foliar absorption of phosphates labelled with {sup 32}P and applied with or without magnesium sulfate on the first leaf of pumpkin seedlings have been studied. The magnesium sulfate applied with the phosphate reduces plainly the absorption rate of {sup 32}P. (O.M.) [French] Nous avons etudie l'absorption foliaire de phosphates marques au {sup 32}P appliques, avec et sans sulfate de magnesium, sur la premiere feuille de jeunes plants de potirons. Le sulfate de magnesium applique avec le phosphate diminue nettement le taux d'absorption du {sup 32}P. (auteur)

  16. Synthesis of magnesium aluminate spinel by periclase and alumina chlorination

    International Nuclear Information System (INIS)

    Orosco, Pablo; Barbosa, Lucía; Ruiz, María del Carmen

    2014-01-01

    Highlights: • Use of chlorination for the synthesis of magnesium aluminate spinel. • The reagents used were alumina, periclase and chlorine. • Isothermal and non-isothermal assays were performed in air and Cl 2 –N 2 flows. • The chlorination produced magnesium aluminate spinel at 700 °C. • Selectivity of the chlorination reaction to obtain spinel is very high. - Abstract: A pyrometallurgical route for the synthesis of magnesium aluminate spinel by thermal treatment of a mechanical mixture containing 29 wt% MgO (periclase) and 71 wt% Al 2 O 3 (alumina) in chlorine atmosphere was developed and the results were compared with those obtained by calcining the same mixture of oxides in air atmosphere. Isothermal and non-isothermal assays were performed in an experimental piece of equipment adapted to work in corrosive atmospheres. Both reagents and products were analyzed by differential thermal analysis (DTA), X-ray diffraction (XRD) and X-ray fluorescence (XRF). Thermal treatment in Cl 2 atmosphere of the MgO–Al 2 O 3 mixture produces magnesium aluminate spinel at 700 °C, while in air, magnesium spinel is generated at 930 °C. The synthesis reaction of magnesium aluminate spinel was complete at 800 °C

  17. Reactions of zinc hydride and magnesium hydride with pyridine; synthesis and characterization of 1,4-dihydro-1-pyridylzinc and -magnesium complexes

    NARCIS (Netherlands)

    Koning, A.J. de; Boersma, J.; Kerk, G.J.M. van der

    1980-01-01

    The synthesis and characterization of 1,4-dihydro-1-pyridylzinc and -magnesium complexes are described. Zinc hydride and magnesium hydride dissolve in and react with pyridine, and the reaction has been studied in detail in the case of zinc hydride. Evaporation of the solvent after 1–2 hours at 0°C

  18. Safety and efficacy of Bolus administration of magnesium sulphate ...

    African Journals Online (AJOL)

    Safety and efficacy of Bolus administration of magnesium sulphate for preeclampsia. ... On-going research is addressing its administration in terms of dosage, duration and safety. Objective: We evaluated a ... Keywords: safety, efficacy, bolus magnesium sulphate, preeclampsia, University of Benin Teaching Hospital

  19. Electron microscope study of vacancy clusters produced by quenching in magnesium; Etude par microscopie electronique des amas de lacunes crees par trempe dans le magnesium

    Energy Technology Data Exchange (ETDEWEB)

    Levy, V; Espinasse, J; Mairy, C; Hillairet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Vacancy clustering in quenched magnesium has been studied by transmission electron microscopy. The nature of the vacancy loops observed, seems to depend essentially on the impurity content of the metal; this effect can be attributed to a variation of the stacking fault energy of magnesium due to impurities. (authors) [French] On a etudie par microscopie electronique en transmission les defauts crees par trempe dans le magnesium. Un effet considerable des impuretes du metal sur la nature des boucles obtenues par condensation de lacunes a ete mis en evidence; cet effet semble s'expliquer de facon satisfaisante par un abaissement de l'energie de faute d'empilement du magnesium du aux impuretes. (auteur)

  20. CRYSTALLIZATION EXPERIMENTS ON AMORPHOUS MAGNESIUM SILICATE. II. EFFECT OF STACKING FAULTS ON INFRARED SPECTRA OF ENSTATITE

    International Nuclear Information System (INIS)

    Murata, K.; Chihara, H.; Koike, C.; Takakura, T.; Imai, Y.; Tsuchiyama, A.; Noguchi, T.

    2009-01-01

    We carried out experiments of low-temperature infrared spectroscopy and transmission electron microscopy of enstatite (MgSiO 3 ) synthesized by heating of amorphous magnesium silicate. There is a discrepancy between the infrared feature of enstatite obtained in this experiment and that of fine powdered single crystals. This reflects stacking disorder of enstatite. We show that circumstellar dust emission of enstatite is similar to the infrared feature measured in this experiment. This result strongly suggests that circumstellar enstatite has abundant stacking faults and is different from the single crystal.

  1. Theoretical investigation of zero field splitting parameter of Cr{sup 3+} doped diammonium hexaaqua magnesium sulfate

    Energy Technology Data Exchange (ETDEWEB)

    Kripal, Ram, E-mail: ram_kripal2001@rediffmail.com; Yadav, Awadhesh Kumar, E-mail: aky.physics@gmail.com

    2015-01-01

    The zero field splitting parameter D of Cr{sup 3+} doped diammonium hexaaqua magnesium sulfate (DHMS) are calculated with perturbation formula using crystal field (CF) parameters from superposition model. The theoretically calculated ZFS parameters for Cr{sup 3+} in DHMS single crystal are compared with the experimental value obtained by electron paramagnetic resonance (EPR). The theoretical ZFS parameter D is similar to that from experiment. The energy band positions of optical absorption spectra of Cr{sup 3+} doped DHMS single crystal are calculated with CFA package, which are in good match with experimental values.

  2. The influence of modification on the thermophysical properties of magnesium wrought alloys

    NARCIS (Netherlands)

    Moldovan, P.; Popescu, G.; Miculescu, M.; Bojin, D.; Dimitriu, S.; Sillekens, W.H.

    2009-01-01

    Magnesium is the lightest engineering metal and has a great potential due to its raw material large natural reverse and interesting properties. Magnesium alloys are attracting increasing attention for industry for weight reduction and high fuel efficiency. Magnesium alloys are attractive

  3. Magnesium and its transport in tilapia and carp: A study based on nuclear methods. Thesis

    Energy Technology Data Exchange (ETDEWEB)

    van der Velden, J.A.

    1993-01-01

    The experiments described in this thesis deal with the production of radiotracers for magnesium and the magnesium metabolism of freshwater tilapia and carp. In chapter 2 the technique of instrumental neutron activation analysis, and the production and properties of two radioisotopes of magnesium are described. In chapter 3 the magnesium distribution and the magnesium inventory of carp and tilapia is described, mainly by the use of instrumental neutron activation analysis. Chapter 4 deals with magnesium transport (in vivo and in vitro) between the water and fish and food and fish. In chapter 5 effects of a low-magnesium diet on tissue mineral concentrations, on the ion regulation and on magnesium transport of fish is described. Chapter 6 deals with the effects of low ambient magnesium on early life stages of the fish.

  4. Magnesium sacrificial anode behavior at elevated temperature

    International Nuclear Information System (INIS)

    Othman, Mohsen Othman

    2006-01-01

    Magnesium sacrificial anode coupled to mild steel was tasted in sodium chloride and tap water environments at elevated temperatures. The anode failed to protect the mild steel specimens in tap water environment at all temperatures specified. This was partly due to low conductivity of this medium. The temperature factor did not help to activate the anode in this medium. In sodium chloride environment the anode demonstrated good protection for steel cathodes. The weight loss was high for magnesium in sodium chloride environment particularly beyond 60 degree centigrade. In tap water environment the weight loss was negligible for the anode. It also suffered localized shallow pitting corrosion. Magnesium anode cannot be utilized where high temperature is involved particularly in high conductivity mediums. Protection of structures containing high resistivity waters is not feasible using sacrificial anode system. (author)

  5. EFFECTS OF MAGNESIUM PEMOLINE UPON HUMAN LEARNING, MEMORY, AND PERFORMANCE TESTS.

    Science.gov (United States)

    SMITH, RONALD G.

    THIS STUDY WAS CONDUCTED DURING 1966 TO DETERMINE THE EFFECTS OF MAGNESIUM PEMOLINE (A COMBINATION OF 2-IMINO-5-PHENYL-4-OXAZOLIDINONE AND MAGNESIUM HYDROXIDE) ON A VARIETY OF HUMAN LEARNING, MEMORY, AND PERFORMANCE TASKS. MAGNESIUM PEMOLINE (25 OR 37.5 MG) OR A PLACEBO WAS ADMINISTERED ORALLY ON A DOUBLE-BLIND BASIS TO INTELLIGENCE-MATCHED GROUPS…

  6. Korelasi Kadar Magnesium Serum dengan Albuminuria pada Pasien Diabetes Melitus Tipe 2

    Directory of Open Access Journals (Sweden)

    Tri Juli Edi Tarigan

    2015-12-01

    Full Text Available Tujuan penelitian ini adalah untuk mengetahui peran magnesium pada nefropati diabetes dan mendapatkan proporsi albuminuria pada pasien DM tipe 2 dengan hipomagnesemia dan magnesium normal serta mendapatkan korelasi kadar Mg dengan albuminuria. Penelitian menggunakan desain cross sectional dengan consecutive sampling pada pasien DM tipe 2 yang terdiagnosis nefropati diabetes di Poliklinik Diabetes RSCM pada bulan Maret-Juni 2014. Dilakukan anamnesis faktor risiko, pemeriksaan fisik, kadar magnesium, albumine creatinine ratio dan A1C. Terdapat 38 subjek yang diikutsertakan dalam penelitian yang sebagian besar berusia lebih 50 tahun dan memiliki kontrol glikemik yang buruk (81,6%. Pada subjek penelitian yang memiliki kadar Mg<1,7 mg/dl 80% mengalami albuminuria, sedangkan pada subjek yang memiliki kadar Mg ≥ 1,7 mg/ dl sebanyak 63,6% mengalami albuminuria. Didapatkan koefisien korelasi sebesar 0,006 yang menunjukkan hubungan yang lemah antara kadar magnesium dalam darah dengan albuminuria. Disimpulkan tidak terdapat korelasi antara kadar magnesium dengan derajat albuminuria. Kata kunci: kadar magnesium, albuminuria, diabetes melitus tipe 2   Correlation between Magnesium Level and Albuminuria in Patients with Type 2 Diabetes Abstract The purposes of this study are to know: the role of magnesium in diabetic nephropathy, the proportion of albuminuria in type 2 DM with hypomagnesemia and normal magnesium level, and correlation between magnesium level and albuminuria. This cross-sectional study was done in Diabetes Clinic RSCM from March to June 2014 with consecutive sampling for type 2 DM patients who had been diagnosed with diabetic nephropathy. History taking, physical exam, albumin creatinine ratio test, and A1c level were done. Thirty eight subjects included in this study were mostly more than 50 years old and had poor glycemic control (81,6%. 80% of subjects with Mg level < 1.7 mg/dl experienced albuminuria and 63.6% of subjects with Mg level

  7. Resonance ionization spectroscopy of argon, krypton, and xenon using vacuum ultraviolet light

    International Nuclear Information System (INIS)

    Kramer, S.D.

    1984-04-01

    Resonant, single-photon excitation of ground state inert gases requires light in the vacuum ultraviolet spectral region. This paper discusses methods for generating this light. Efficient schemes for ionizing argon, krypton, and xenon using resonant, stepwise single-photon excitation are presented

  8. Influence of corrosive solutions on microhardness and chemistry of magnesium oxide /001/ surfaces

    Science.gov (United States)

    Ishigaki, H.; Miyoshi, K.; Buckley, D. H.

    1982-01-01

    X-ray photoelectron spectroscopy analyses and hardness experiments were conducted on cleaved magnesium oxide /001/ surfaces. The magnesium oxide bulk crystals were cleaved to specimen size along the /001/ surface, and indentations were made on the cleaved surface in corrosive solutions containing HCl, NaOH, or HNO3 and in water without exposing the specimen to any other environment. The results indicated that chloride (such as MgCl2) and sodium films are formed on the magnesium oxide surface as a result of interactions between an HCl-containing solution and a cleaved magnesium oxide surface. The chloride films soften the magnesium oxide surface. In this case microhardness is strongly influenced by the pH value of the solution. The lower the pH, the lower the microhardness. Sodium films, which are formed on the magnesium oxide surface exposed to an NaOH containing solution, do not soften the magnesium oxide surface.

  9. CTMC calculation of Si2+ + H impact ionization

    International Nuclear Information System (INIS)

    Liu Chunlei; He Bin; Ning Ye; Yan Jun; Wang Jianguo

    2005-01-01

    The Si 2+ + H collision ionization is studied using classical trajectory Monte-Carlo (CTMC) method. The total cross section as functions of the energy of incident projectile, single differential cross section and double differential cross section as a functions of the energy and the angle of the ejected electron are calculated. The ionization mechanisms of soft collision, electron capture to the continuum state, binary encounter collision are demonstrated. The effect of 'saddle point' is also discussed by calculating the ejected electron distribution depending on the ratios of distances between electron and target and between electron and projectile. (author)

  10. Distribution of magnesium in groundwater of Serbia

    OpenAIRE

    Milosavljević Jovana; Andrijašević Jakov; Todorović Maja

    2013-01-01

    Magnesium is chemical element commonly found in the environment and the main constituent of many types of minerals and rocks. This element is also essential to man. Owing to its abundance in nature, magnesium is present in all water resources and generally occur as the dominant cation, with calcium, in those that feature low TDS levels, whose origin is associated with large formations of sedimentary rocks (limestones, dolomites), and to a lesser extent with...

  11. Distinction between magnesium diboride and tetraboride by kelvin probe force microscopy; Unterscheidung von Magnesiumdiborid und Magnesiumtetraborid durch Kelvinsondenkraftmikroskopie

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Du-Na; Caron, Arnaud; Park, Hai Woong [KoreaTech - Korea Univ. of Technology and Education, Chungnam (Korea, Republic of). School of Energy, Materials and Chemical Engineering

    2016-08-15

    We analyze mixtures of magnesium diboride and tetraboride synthesized with magnesium powders of different shapes. To distinguish between magnesium diboride and tetraboride we use the contrast of kelvin probe force microscopy. The microstructural morphology strongly depends on the shape of the magnesium powders used in the reaction between magnesium and magnesium tetraboride to form magnesium diboride. With spherical magnesium powder an equiaxed microstructure of magnesium diboride is formed with residual magnesium tetraboride at the grain boundaries. With plate-like magnesium powders elongated magnesium diboride grains are formed. In this case, residual magnesium tetraboride is found to agglomerate.

  12. HUBUNGAN ASUPAN MAGNESIUM DAN KADAR GLUKOSA DARAH PUASA PASIEN RAWAT JALAN DIABETES MELITUS TIPE 2 (CORRELATION BETWEEN MAGNESIUM INTAKE AND FASTING BLOOD GLUCOSE LEVEL IN OUTPATIENTS WITH TYPE 2 DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Anggun Faradhita

    2014-12-01

    Diabetes Mellitus type 2 reveals resistance insulin. Inadequate magnesium consumption has been reported to promote insulin resistance. The potential role of magnesium in Diabetes Mellitus is improving insulin sensitivity. Previous studies indicated that there is an inverse correlation between magnesium intakes and the incidence of type 2 Diabetes. This study aimed to analyze the association between magnesium intake and fasting blood glucose levels in outpatients with Type 2 Diabetes Mellitus in Al Ihsan Hospital. Cross-sectional study in 46 participants was taken by purposive sampling. Data collection was conducted in June-July 2013 which included common data, exercise habits, nutritional status, energy intake, magnesium intake, protein intake, fiber intake and fasting blood glucose levels. This research showed that there was a significant association between magnesium intake and fasting blood glucose levels of patients (p < 0.001 with a correlation of moderate strength (r = -0.562, high magnesium intake was followed by a decrease in fasting blood glucose levels. It is then suggested that people with diabetes mellitus consume adequate amounts of magnesium and set a good diet and regular exercise as a step in the control of blood glucose levels. Keywords: Magnesium Intake, Fasting Blood Glucose, Type 2 Diabetes Mellitus

  13. Ionization effects in electronic inner-shells of ionized atoms

    International Nuclear Information System (INIS)

    Shchornak, G.

    1983-01-01

    A review of the atomic physics of ionization atoms has been presented. Interaction and structure effects in atomic shells, correlated to the occurrence of vacancies in several subshells of the atom have been considered. The methods of calculations of atomic states and wave functions have been reviewed. The energy shift of characteristic X-rays is discussed as a function of the ionization stage of the atom. The influence of inner and outer-shell vacancies on the energy of the X-rays is shown in detail. The influence of chemical effects on the parameters of X-rays is also taken into account. Further on, the change of transition probabilities in radiative and non-radiative transitions by changing stage of ionization is discussed; and among them the leading part of Auger and Coster-Kronig transitions by the arearrangement of the atomic states is shown. The influence of non-radiative electronic transitions on ionization cross-sections for multiple ionization is discussed. Using these results, ionization cross-sections for direct and indirect processes for several ionization stages are given

  14. Mass spectrometric evidence for suprathermal ionization in an inductively coupled argon plasma

    International Nuclear Information System (INIS)

    Houk, R.S.; Svec, H.J.; Fassel, V.A.

    1981-01-01

    Mass spectra have been obtained of species in the axial channel of an inductively coupled argon plasma by extracting ions from the inductively coupled plasma into a vacuum system housing a quadrupole mass spectrometer. Ionization temperatures (T/sub ion/) are obtained from relative count rates of m/z-resolved ions according to two general types of ionization equilibrium considerations: (a) the radio of doubly/singly charged ions of the same element, and (b) the ratio of singly charged ions from two elements of different ionization energy. The T/sub ion/ values derived from measurement of Ar +2 /Ar + , Ba +2 /Ba + , Sr +2 /Sr + , and Cd + /I + are all greater than those expected from excitation temperatures measured by other workers. The latter three values for T/sub ion/ are in reasonable agreement with values obtained by optical spectrometry for a variety of argon inductively coupled plasmas

  15. Effectiveness of projectile screening in single and multiple ionization of Ne by B{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, W.; Luna, H.; Santos, A. C. F.; Montenegro, E. C. [Instituto de Fisica, Universidade Federal do Rio de Janeiro, Caixa Postal 68528, Rio de Janeiro, 21945-970 RJ (Brazil); DuBois, R. D. [Department of Physics, Missouri University of Science and Technology, Rolla, Missouri 65409 (United States); Montanari, C. C.; Miraglia, J. E. [Instituto de Astronomia y Fisica del Espacio, Casilla de Correo 67, Sucursal 28, C1428EGA, Buenos Aires (Argentina)

    2011-10-15

    Pure multiple ionization cross sections of Ne by B{sup 2+} projectiles have been measured in the energy range of 0.75 to 4.0 MeV and calculated using the continuum distorted wave-eikonal initial state approximation. The experiment and calculations show that the ionization cross sections by B{sup 2+}, principally for the production of highly charged recoils, is strongly enhanced when compared to the bare projectile with the same charge state, He{sup 2+}, at the same velocities.

  16. ROLE OF MAGNESIUM IN HEADACHE PATHOGENESIS IN CHILDREN AND ADOLESCENTS

    Directory of Open Access Journals (Sweden)

    E. S. Akarachkova

    2013-01-01

    Full Text Available Article is dedicated to the problem of headache in children. This pathology is being found more frequently in pediatric and children’s neurologic practice. The authors examine headache pathogenesis from the position of magnesium deficiency. Analysis of results of the modern studies on magnesium deficiency and its correction in patients with headache indicates that magnesium metabolism may play an important role both in pathogenesis of different headache types and in its treatment and prevention.

  17. Two-photon double ionization of the helium atom by ultrashort pulses

    International Nuclear Information System (INIS)

    Palacios, Alicia; Horner, Daniel A.; Rescigno, Thomas N.; McCurdy, C. William

    2010-01-01

    Two-photon double ionization of the helium atom was the subject of early experiments at FLASH and will be the subject of future benchmark measurements of the associated electron angular and energy distributions. As the photon energy of a single femtosecond pulse is raised from the threshold for two-photon double ionization at 39.5 eV to beyond the sequential ionization threshold at 54.4 eV, the electron ejection dynamics change from the highly correlated motion associated with nonsequential absorption to the much less correlated sequential ionization process. The signatures of both processes have been predicted in accurate ab initio calculations of the joint angular and energy distributions of the electrons, and those predictions contain some surprises. The dominant terms that contribute to sequential ionization make their presence apparent several eV below that threshold. In two-color pump probe experiments with short pulses whose central frequencies require that the sequential ionization process necessarily dominates, a two-electron interference pattern emerges that depends on the pulse delay and the spin state of the atom.

  18. Severe selective magnesium malabsorption: tests of tolerance of oral magnesium supplements.

    Science.gov (United States)

    Mettey, R; Guillard, O; Merle, P; Maillet-Picker, F

    1990-12-01

    Since his birth, we have been monitoring a 12-year-old boy suffering from selective severe magnesium malabsorption. Our essential problem is to prepare a form of galena with acceptable taste, tolerated by the digestive tract and well absorbed; also, the carrier compound must not cause short- or long-term side effects. An additional factor is the steadily increasing need for magnesium from 1 mmol/kg.d at 1 year to 14 mmol/kg.d at present age (345 mg/kg.d). The galena forms currently on sale were, with the exception of lactate and pyrollidone carboxylate, immediately rejected since they contain insufficient Mg2+. Following short trials resulting in diarrhoea, the other two preparations were also rejected. We then constituted - and also abandoned - our own galena compounds: aspartate (bitterness), aspartate + glycerophosphate (GLP) (bitterness), glutamate + GLP ('Chinese restaurant syndrome' and fear of the long term toxic effect of the glutamate), gluconate (excessive volume: 11/1 proportion with Mg2+). A recent test featuring GLP of Mg 40 g + cocoa butter 40 g + cocoa 10 g, brought about vomiting and diarrhoea, and was not adequately absorbed. The best tolerated formula is: Mg GLP 21.33 g; saccharose 6 g; aspartam 1 g; gelatin 0.5 g; citric acid, conserving agent, fruity aroma; water: qs 100 g. Such composition yields a caramel cream absorbed in five small portions, at a daily quantity of 375 g (80 g GLP Mg, 10 g Mg2+). Vitamin B6, which promotes intestinal absorption of magnesium, must be given separately in tablet form at a dose of 1 g/d, since it causes nausea if it is included in the Mg preparation.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. A 0.18 micrometer CMOS Thermopile Readout ASIC Immune to 50 MRAD Total Ionizing Dose (SI) and Single Event Latchup to 174MeV-cm(exp 2)/mg

    Science.gov (United States)

    Quilligan, Gerard T.; Aslam, Shahid; Lakew, Brook; DuMonthier, Jeffery J.; Katz, Richard B.; Kleyner, Igor

    2014-01-01

    Radiation hardened by design (RHBD) techniques allow commercial CMOS circuits to operate in high total ionizing dose and particle fluence environments. Our radiation hard multi-channel digitizer (MCD) ASIC (Figure 1) is a versatile analog system on a chip (SoC) fabricated in 180nm CMOS. It provides 18 chopper stabilized amplifier channels, a 16- bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The MCD was evaluated at Goddard Space Flight Center and Texas A&M University's radiation effects facilities and found to be immune to single event latchup (SEL) and total ionizing dose (TID) at 174 MeV-cm(exp 2)/mg and 50 Mrad (Si) respectively.

  20. Heated Hydro-Mechanical Deep Drawing of Magnesium Sheet Metal

    Science.gov (United States)

    Kurz, Gerrit

    In order to reduce fuel consumption efforts have been made to decrease the weight of automobile constructions by increasing the use of lightweight materials. In this field of application magnesium alloys are important because of their low density. A promising alternative to large surfaced and thin die casting parts has been found in construction parts that are manufactured by sheet metal forming of magnesium. Magnesium alloys show a limited formability at room temperature. A considerable improvement of formability can be achieved by heating the material. Formability increases above a temperature of approximately T = 225 °C.