WorldWideScience

Sample records for singly clamped beams

  1. A piezoelectric vibration harvester based on clamped-guided beams

    NARCIS (Netherlands)

    Wang, Z.; Matova, S.; Elfrink, R.; Jambunathan, M.; Nooijer, C. de; Schaijk, R. van; Vullers, R.J.M.

    2012-01-01

    The paper addresses the design, modeling, fabrication and experimental results of a piezoelectric energy harvester based on clamped-guided beams. The design is featured by shorter mass displacement and higher reliability than cantilever beams. Two separate sets of capacitors allow exploiting both

  2. Single molecule study of a processivity clamp sliding on DNA

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, T A; Kwon, Y; Johnson, A; Hollars, C; O?Donnell, M; Camarero, J A; Barsky, D

    2007-07-05

    Using solution based single molecule spectroscopy, we study the motion of the polIII {beta}-subunit DNA sliding clamp ('{beta}-clamp') on DNA. Present in all cellular (and some viral) forms of life, DNA sliding clamps attach to polymerases and allow rapid, processive replication of DNA. In the absence of other proteins, the DNA sliding clamps are thought to 'freely slide' along the DNA; however, the abundance of positively charged residues along the inner surface may create favorable electrostatic contact with the highly negatively charged DNA. We have performed single-molecule measurements on a fluorescently labeled {beta}-clamp loaded onto freely diffusing plasmids annealed with fluorescently labeled primers of up to 90 bases. We find that the diffusion constant for 1D diffusion of the {beta}-clamp on DNA satisfies D {le} 10{sup -14} cm{sup 2}/s, much slower than the frictionless limit of D = 10{sup -10} cm{sup 2}/s. We find that the {beta} clamp remains at the 3-foot end in the presence of E. coli single-stranded binding protein (SSB), which would allow for a sliding clamp to wait for binding of the DNA polymerase. Replacement of SSB with Human RP-A eliminates this interaction; free movement of sliding clamp and poor binding of clamp loader to the junction allows sliding clamp to accumulate on DNA. This result implies that the clamp not only acts as a tether, but also a placeholder.

  3. Single Beam Holography.

    Science.gov (United States)

    Chen, Hsuan; Ruterbusch, Paul H.

    1979-01-01

    Discusses how holography can be used as part of undergraduate physics laboratories. The authors propose a single beam technique of holography, which will reduce the recording scheme as well as relax the isolation requirements. (HM)

  4. Cryogenic Clamp-on Ultrasonic Flowmeters using Single Crystal Piezoelectric Transducers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Clamp-on ultrasound cryogenic flowmeters using single crystal piezoelectric transducers are proposed to enable reliable, accurate cryogenic instrumentation needs in...

  5. Advanced patch-clamp techniques and single-channel analysis

    NARCIS (Netherlands)

    Biskup, B; Elzenga, JTM; Homann, U; Thiel, G; Wissing, F; Maathuis, FJM

    Much of our knowledge of ion-transport mechanisms in plant cell membranes comes from experiments using voltage-clamp. This technique allows the measurement of ionic currents across the membrane, whilst the voltage is held under experimental control. The patch-clamp technique was developed to study

  6. Study of the nonlinearities in micromechanical clamped–clamped beam resonators using stroboscopic SEM

    International Nuclear Information System (INIS)

    Shao, L C; Wong, C L; Palaniapan, M

    2008-01-01

    This paper presents a comprehensive study of the nonlinearities in micromechanical clamped–clamped beam resonators using a stroboscopic scanning electron microscopy (SEM) technique. Stroboscopic SEM allows direct imaging and measurement of the resonator's momentary displacement, hence eliminating the uncertainties associated with the conventional characterization methods. Five different silicon-on-insulator (SOI) comb-drive clamped–clamped beam resonators with resonant frequencies ranging from 113 kHz to 239 kHz were designed, fabricated and tested to investigate how their nonlinearities are related to the device dimensions. Both the theoretical analysis and experimental results conclusively show that the critical vibration amplitude of the resonator is around 1% of the beam width in a vacuum and is relatively independent of the beam length. Furthermore, it is found that the maximum storable energy of the resonator can be significantly increased by increasing the beam width and/or reducing the beam length if there are no restrictions on these dimensions. On the other hand, if a specific resonant frequency needs to be maintained, the maximum storable energy can be improved by increasing both the beam width and length by the same factor. Such a study not only helps to reveal the intrinsic nonlinear properties of the micromechanical clamped–clamped beam resonators, but also provides useful design guidelines for engineers to optimize the overall device performance

  7. An analytical model of a clamped sandwich beam under low-impulse mass impact

    Directory of Open Access Journals (Sweden)

    Wen-zheng Jiang

    Full Text Available An analytical model is developed to examine a low impulsive projectile impact on a fully clamped sandwich beams by considering the coupled responses of the core and the face sheets. Firstly, based on the dynamic properties of foam cores, the sandwich beam is modeled as two rigid perfectly-plastic beams connected by rigid perfectly-plastic springs. Different from the previous sandwich beam model, the transverse compression and bending effects of the foam core are considered in the whole deformation process. Based on this model, different coupling mechanism of sandwich beams are constructed so that an analytical solution considering small deformation is derived. The coupled dynamic responses of sandwich beams with different core strengths are investigated. The results indicate that this model improves the prediction accuracy of the responses of the sandwich beams, and is available for the situation when the sandwich beam undergoes moderate global deformation.

  8. Impedance spectra of patch clamp scenarios for single cells immobilized on a lab-on-a-chip

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2014-01-01

    A simple method based on impedance spectroscopy (IS) was developed to distinguish between different patch clamp modes for single cells trapped on microapertures in a patch clamp microchannel array designed for patch clamping on cultured cells. The method allows detecting via impedance analysis wh...

  9. Boundary discontinuous Fourier analysis of thick beams with clamped and simply supported edges via CUF

    Directory of Open Access Journals (Sweden)

    F.G. CANALES

    2017-10-01

    Full Text Available This paper presents an analytical solution for static analysis of thick rectangular beams with different boundary conditions. Carrera’s Unified Formulation (CUF is used in order to consider shear deformation theories of arbitrary order. The novelty of the present work is that a boundary discontinuous Fourier approach is used to consider clamped boundary conditions in the analytical solution, unlike Navier-type solutions which are restricted to simply supported beams. Governing equations are obtained by employing the principle of virtual work. The numerical accuracy of results is ascertained by studying the convergence of the solution and comparing the results to those of a 3D finite element solution. Beams subjected to bending due to a uniform pressure load and subjected to torsion due to opposite linear forces are considered. Overall, accurate results close to those of 3D finite element solutions are obtained, which can be used to validate finite element results or other approximate methods.

  10. Veering and nonlinear interactions of a clamped beam in bending and torsion

    Science.gov (United States)

    Ehrhardt, David A.; Hill, Thomas L.; Neild, Simon A.; Cooper, Jonathan E.

    2018-03-01

    Understanding the linear and nonlinear dynamic behaviour of beams is critical for the design of many engineering structures such as spacecraft antennae, aircraft wings, and turbine blades. When the eigenvalues of such structures are closely-spaced, nonlinearity may lead to interactions between the underlying linear normal modes (LNMs). This work considers a clamped-clamped beam which exhibits nonlinear behaviour due to axial tension from large amplitudes of deformation. An additional cross-beam, mounted transversely and with a movable mass at each tip, allows tuning of the primary torsion LNM such that it is close to the primary bending LNM. Perturbing the location of one mass relative to that of the other leads to veering between the eigenvalues of the bending and torsion LNMs. For a number of selected geometries in the region of veering, a nonlinear reduced order model (NLROM) is created and the nonlinear normal modes (NNMs) are used to describe the underlying nonlinear behaviour of the structure. The relationship between the 'closeness' of the eigenvalues and the nonlinear dynamic behaviour is demonstrated in the NNM backbone curves, and veering-like behaviour is observed. Finally, the forced and damped dynamics of the structure are predicted using several analytical and numerical tools and are compared to experimental measurements. As well as showing a good agreement between the predicted and measured responses, phenomena such as a 1:1 internal resonance and quasi-periodic behaviour are identified.

  11. Soft-Switched Neutral-Point-Clamped Single-Phase Boost Rectifier

    Science.gov (United States)

    Itoh, Ryozo; Ishizaka, Kouichi

    A soft-switched neutral-point-clamped single-phase boost rectifier capable of compensating the imbalance load voltage is studied. This is based on a single-phase rectifier, in which an inductor is placed in series with the AC supply to resonate with a capacitor connected across the DC output of a full-bridge rectifier and the switching transition is mainly governed by a series resonance. The experimental prototype using insulated-gate bipolar transistors is implemented to investigate the operation under the charge control. The experimental results confirm that the rectifier has a neutral-point-clamp feature providing a good quality AC current.

  12. Macromechanical parametric amplification with a base-excited doubly clamped beam

    DEFF Research Database (Denmark)

    Neumeyer, Stefan; Thomsen, Jon Juel

    2013-01-01

    Parametric amplification is realized by adding parametric excitation to externally driven near-resonant oscillations. The effect of specific cubic nonlinearities on the parametrically amplified steady-state vibrations and gain is investigated theoretically. Here, gain is defined as the ratio...... of steady-state vibration amplitude of the directly and parametrically excited system, to vibration amplitude of the directly excited only system. The nonlinear effect of midplane stretching is compared to the effects of nonlinear inertia and curvature. An approximate analytical expression for the vibration...... amplitude is derived. For a given small level of transverse displacement for both the cantilever and doubly clamped beam, the effect of midplane stretching is dominant compared to those caused by nonlinear inertia and curvature. It was found that the beam slenderness ratio can be used as an effective design...

  13. A single electrode voltage, current- and patch-clamp amplifier with complete stable series resistance compensation.

    Science.gov (United States)

    Strickholm, A

    1995-01-01

    An input headstage for single electrode voltage and current clamping is described which permits selecting desired operational modes during an experiment. These include cell attached or whole cell patch clamping, single micro-electrode voltage or current clamping, potential recording, iontophoresis and voltammetry. Input electrode series resistance with the electrode inserted in a cell or during whole cell patch clamping can be measured at any time. The unique circuitry allows complete compensation of the series resistance with high frequency response. The input series electrode resistance can also vary considerably around an initially set 100% compensation with intrinsic stability. An accelerator 'supercharger' or 'booster circuit' is included which can shorten the rise time of membrane potential to the command potential by a hundredfold. This improves the recording of early ion channel currents. Feedback resistors are selected remotely for the specific experimental need. Signal resolution in patch clamping is that expected from the thermal noise of the feedback resistor and electrode to membrane seal resistance. This headstage circuitry design thus allows interchangeable modes of operation and parameters during an experiment to obtain optimal conditions for signal detection and frequency response.

  14. Single base pair mutation analysis by PNA directed PCR clamping

    DEFF Research Database (Denmark)

    Ørum, H.; Nielsen, P.E.; Egholm, M.

    1993-01-01

    A novel method that allows direct analysis of single base mutation by the polymerase chain reaction (PCR) is described. The method utilizes the finding that PNAs (peptide nucleic acids) recognize and bind to their complementary nucleic acid sequences with higher thermal stability and specificity...

  15. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...

  16. Adjustable static and dynamic actuation of clamped-guided beams using electrothermal axial loads

    KAUST Repository

    Alcheikh, Nouha

    2018-02-14

    The paper presents adjustable static and dynamic actuations of in-plane clamped-guided beams. The structures, of variable stiffness, can be used as highly tunable resonators and actuators. Axial loads are applied through electrothermal U-shaped and flexure beams actuators stacked near the edges of curved (arch) beams. The electrothermal actuators can be configurred in various ways to adjust as desired the mechanical stiffness of the structures; thereby controlling their deformation stroke as actuators and their operating resonance frequency as resonators. The experimental and finite element results demonstrate the flexibility of the designs in terms of static displacements and resonance frequencies of the first and second symmetric modes of the arches. The results show considerable increase in the resonance frequency and deflection of the microbeam upon changing end actuation conditions, which can be promising for low voltage actuation and tunable resonators applications, such as filters and memory devices. As case studies of potential device configurations of the proposed design, we demonstrate eight possibilities of achieving new static and dynamic behaviors, which produce various resonance frequencies and static displacement curves. The ability to actively shift the entire frequency response curve of a device is desirable for several applications to compensate for in-use anchor degradations and deformations. As an example, we experimentally demonstrate using the device as a resonant logic gate, with active resonance tuning, showing fundamental 2-bit logic functions, such as AND,XOR, and NOR.

  17. Eigensensitivity analysis of rotating clamped uniform beams with the asymptotic numerical method

    Science.gov (United States)

    Bekhoucha, F.; Rechak, S.; Cadou, J. M.

    2016-12-01

    In this paper, free vibrations of a rotating clamped Euler-Bernoulli beams with uniform cross section are studied using continuation method, namely asymptotic numerical method. The governing equations of motion are derived using Lagrange's method. The kinetic and strain energy expression are derived from Rayleigh-Ritz method using a set of hybrid variables and based on a linear deflection assumption. The derived equations are transformed in two eigenvalue problems, where the first is a linear gyroscopic eigenvalue problem and presents the coupled lagging and stretch motions through gyroscopic terms. While the second is standard eigenvalue problem and corresponds to the flapping motion. Those two eigenvalue problems are transformed into two functionals treated by continuation method, the Asymptotic Numerical Method. New method proposed for the solution of the linear gyroscopic system based on an augmented system, which transforms the original problem to a standard form with real symmetric matrices. By using some techniques to resolve these singular problems by the continuation method, evolution curves of the natural frequencies against dimensionless angular velocity are determined. At high angular velocity, some singular points, due to the linear elastic assumption, are computed. Numerical tests of convergence are conducted and the obtained results are compared to the exact values. Results obtained by continuation are compared to those computed with discrete eigenvalue problem.

  18. Analysis of failed and nickel-coated 3093 beam clamp components at the East Tennessee Technology Park (ETTP).

    Energy Technology Data Exchange (ETDEWEB)

    Singh, D.; Pappacena, K.; Gaviria, J.; Burtsteva, T.; Nuclear Engineering Division

    2010-10-11

    The U.S. Department of Energy and its contractor, Bechtel Jacobs Company (BJC), are undertaking a major effort to clean up the former gaseous diffusion facility (K-25) located in Oak Ridge, TN. The decontamination and decommissioning activities require systematic removal of contaminated equipment and machinery followed by demolition of the buildings. As part of the cleanup activities, a beam clamp, used for horizontal life lines (HLLs) for fall protection, was discovered to be fractured during routine inspection. The beam clamp (yoke and D-ring) was a component in the HLL system purchased from Reliance Industries LLC. Specifically, the U-shaped stainless steel yoke of the beam clamp failed in a brittle mode at under less than 10% of the rated design capacity of 14,500 lb. The beam clamp had been in service for approximately 16 months. Bechtel Jacobs approached Argonne National Laboratory to assist in identifying the root cause of the failure of the beam clamp. The objectives of this study were to (1) review the prior reports and documents on the subject, (2) understand the possible failure mechanism(s) that resulted in the failed beam clamp components, (3) recommend approaches to mitigate the failure mechanism(s), and (4) evaluate the modified beam clamp assemblies. Energy dispersive x-ray analysis and chemical analysis of the corrosion products on the failed yoke and white residue on an in-service yoke indicated the presence of zinc, sulfur, and calcium. Analysis of rainwater in the complex, as conducted by BJC, indicated the presence of sulfur and calcium. It was concluded that, as a result of galvanic corrosion, zinc from the galvanized components of the beam clamp assembly (D-ring) migrated to the corroded region in the presence of the rainwater. Under mechanical stress, the corrosion process would have accelerated, resulting in the catastrophic failure of the yoke. As suggested by Bechtel Jacobs personnel, hydrogen embrittlement as a consequence of corrosion

  19. The interplay of primer-template DNA phosphorylation status and single-stranded DNA binding proteins in directing clamp loaders to the appropriate polarity of DNA.

    Science.gov (United States)

    Hayner, Jaclyn N; Douma, Lauren G; Bloom, Linda B

    2014-01-01

    Sliding clamps are loaded onto DNA by clamp loaders to serve the critical role of coordinating various enzymes on DNA. Clamp loaders must quickly and efficiently load clamps at primer/template (p/t) junctions containing a duplex region with a free 3'OH (3'DNA), but it is unclear how clamp loaders target these sites. To measure the Escherichia coli and Saccharomyces cerevisiae clamp loader specificity toward 3'DNA, fluorescent β and PCNA clamps were used to measure clamp closing triggered by DNA substrates of differing polarity, testing the role of both the 5'phosphate (5'P) and the presence of single-stranded binding proteins (SSBs). SSBs inhibit clamp loading by both clamp loaders on the incorrect polarity of DNA (5'DNA). The 5'P groups contribute selectivity to differing degrees for the two clamp loaders, suggesting variations in the mechanism by which clamp loaders target 3'DNA. Interestingly, the χ subunit of the E. coli clamp loader is not required for SSB to inhibit clamp loading on phosphorylated 5'DNA, showing that χ·SSB interactions are dispensable. These studies highlight a common role for SSBs in directing clamp loaders to 3'DNA, as well as uncover nuances in the mechanisms by which SSBs perform this vital role. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  20. Analytical study of the frequency shifts of micro and nano clamped–clamped beam resonators due to an added mass

    KAUST Repository

    Bouchaala, Adam M.

    2016-03-18

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped–clamped micro and nano (Carbon nanotube) beams due to an added mass. Based on the Euler–Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes. © 2016 Springer Science+Business Media Dordrecht

  1. A NOVEL SINGLE IMPEDANCE NETWORK BASED NEUTRAL POINT CLAMPED SEVEN LEVEL THREE PHASE INVETER WITH REDUCED CLAMPING DIODES FOR REGENERATIVE APPLICATIONS

    OpenAIRE

    T. A. Raghavendiran; C.L.Kuppuswamy

    2012-01-01

    A Multilevel Inverter (MLI) can eliminate the need for the step-up transformer and reduce the harmonics produced by the inverter. This paper presents Neutral Point Clamped (NPC) seven level inverter with less number of clamping diodes which is suitable for regenerative loads such as three phase induction motor with regenerative braking. To reduce the stress across the main switches, diodes are clamped anti-parallel to the main switches. In Earlier configurations, the numbers of clamping diode...

  2. Single aortic clamping in coronary artery bypass surgery reduces cerebral embolism and improves neurocognitive outcomes.

    Science.gov (United States)

    Gasparovic, Hrvoje; Borojevic, Marko; Malojcic, Branko; Gasparovic, Kristina; Biocina, Bojan

    2013-10-01

    Aortic manipulation releases embolic material, thereby enhancing the probability of adverse neurologic outcomes following coronary artery bypass grafting (CABG). We prospectively evaluated 59 patients undergoing CABG. Patients in the single (SC, n = 37) and multiple clamp (MC, n = 22) groups were comparable in relation to age and operative risk (p > 0.05). Neurocognitive evaluation consisted of the Auditory Verbal Learning Test (AVLT), Color Trails Test A, the Grooved Pegboard test and the Mini-Mental State Examination. Data acquisition was performed preoperatively, early postoperatively and at the 4-month follow-up. Intraoperative transcranial Doppler (TCD) monitoring was used to quantify the embolic load in relation to different aortic clamping strategies. Preoperative neurocognitive results were similar between the groups (p > 0.05). The incidence of postoperative delirium was greater in the MC group but this failed to reach statistical significance (23% vs 8%, p = 0.14). SC patients had fewer embolization signals (270 ± 181 vs 465 ± 160, p < 0.0001). Early postoperative neurocognitive results were depressed in comparison to preoperative values in both groups (p < 0.05 for multiple comparisons). The magnitude of this cognitive depression was greater in the MC group (p < 0.05 for multiple comparisons). Preoperative levels of neurocognition were restored at follow-up in the SC group in all tests except the AVLT. A trend towards improvements in neurocognitive performances at follow-up was also observed in the MC group. Residual attention, motor skill and memory deficits were, however, documented with multiple tests. In conclusion, the embolic burden was significantly lower in the SC group. This TCD imaging outcome translated into fewer early cognition deficits and superior late restoration of function.

  3. Measurements of thermal conductivity and the coefficient of thermal expansion for polysilicon thin films by using double-clamped beams

    Science.gov (United States)

    Liu, Haiyun; Wang, Lei

    2018-01-01

    In this paper, a test structure for simultaneously determining thermal conductivity and the coefficient of thermal expansion (CTE) of polysilicon thin film is proposed. The test structure consists of two double-clamped beams with different lengths. A theoretical model for extracting thermal conductivity and CTE based on electrothermal analysis and resonance frequency approach is developed. Both flat and buckled beams are considered in the theoretical model. The model is confirmed by finite element software ANSYS. The test structures are fabricated by surface micromachined fabrication process. Experiments are carried out in our atmosphere. Thermal conductivity and CTE of polysilicon thin film are obtained to be (29.96  ±  0.92) W · m · K-1 and (2.65  ±  0.03)  ×  10-6 K-1, respectively, with temperature ranging from 300-400 K.

  4. Post clamp

    Science.gov (United States)

    Ramsey, John K. (Inventor); Meyn, Erwin H. (Inventor)

    1990-01-01

    A pair of spaced collars are mounted at right angles on a clamp body by retaining rings which enable the collars to rotate with respect to the clamp body. Mounting posts extend through aligned holes in the collars and clamp body. Each collar can be clamped onto the inserted post while the clamp body remains free to rotate about the post and collar. The clamp body is selectively clamped onto each post.

  5. Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Cavalcanti, Marcelo C.; Farias, Alexandre M.

    2013-01-01

    Modulation strategy is one of the most important issues for three-level neutral-point-clamped inverters in three-phase transformerless photovoltaic systems. A challenge for modulation is how to keep the common-mode voltages constant to reduce the leakage currents. A single-carrier modulation...

  6. Characterization of ryanodine receptor type 1 single channel activity using "on-nucleus" patch clamp.

    Science.gov (United States)

    Wagner, Larry E; Groom, Linda A; Dirksen, Robert T; Yule, David I

    2014-08-01

    In this study, we provide the first description of the biophysical and pharmacological properties of ryanodine receptor type 1 (RyR1) expressed in a native membrane using the on-nucleus configuration of the patch clamp technique. A stable cell line expressing rabbit RyR1 was established (HEK-RyR1) using the FLP-in 293 cell system. In contrast to untransfected cells, RyR1 expression was readily demonstrated by immunoblotting and immunocytochemistry in HEK-RyR1 cells. In addition, the RyR1 agonists 4-CMC and caffeine activated Ca(2+) release that was inhibited by high concentrations of ryanodine. On nucleus patch clamp was performed in nuclei prepared from HEK-RyR1 cells. Raising the [Ca(2+)] in the patch pipette resulted in the appearance of a large conductance cation channel with well resolved kinetics and the absence of prominent subconductance states. Current versus voltage relationships were ohmic and revealed a chord conductance of ∼750pS or 450pS in symmetrical 250mM KCl or CsCl, respectively. The channel activity was markedly enhanced by caffeine and exposure to ryanodine resulted in the appearance of a subconductance state with a conductance ∼40% of the full channel opening with a Po near unity. In total, these properties are entirely consistent with RyR1 channel activity. Exposure of RyR1 channels to cyclic ADP ribose (cADPr), nicotinic acid adenine dinucleotide phosphate (NAADP) or dantrolene did not alter the single channel activity stimulated by Ca(2+), and thus, it is unlikely these molecules directly modulate RyR1 channel activity. In summary, we describe an experimental platform to monitor the single channel properties of RyR channels. We envision that this system will be influential in characterizing disease-associated RyR mutations and the molecular determinants of RyR channel modulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Dynamic Phenylalanine Clamp Interactions Define Single-Channel Polypeptide Translocation through the Anthrax Toxin Protective Antigen Channel.

    Science.gov (United States)

    Ghosal, Koyel; Colby, Jennifer M; Das, Debasis; Joy, Stephen T; Arora, Paramjit S; Krantz, Bryan A

    2017-03-24

    Anthrax toxin is an intracellularly acting toxin where sufficient detail is known about the structure of its channel, allowing for molecular investigations of translocation. The toxin is composed of three proteins, protective antigen (PA), lethal factor (LF), and edema factor (EF). The toxin's translocon, PA, translocates the large enzymes, LF and EF, across the endosomal membrane into the host cell's cytosol. Polypeptide clamps located throughout the PA channel catalyze the translocation of LF and EF. Here, we show that the central peptide clamp, the ϕ clamp, is a dynamic site that governs the overall peptide translocation pathway. Single-channel translocations of a 10-residue, guest-host peptide revealed that there were four states when peptide interacted with the channel. Two of the states had intermediate conductances of 10% and 50% of full conductance. With aromatic guest-host peptides, the 50% conducting intermediate oscillated with the fully blocked state. A Trp guest-host peptide was studied by manipulating its stereochemistry and prenucleating helix formation with a covalent linkage in the place of a hydrogen bond or hydrogen-bond surrogate (HBS). The Trp peptide synthesized with ʟ-amino acids translocated more efficiently than peptides synthesized with D- or alternating D,ʟ-amino acids. HBS stapled Trp peptide exhibited signs of steric hindrance and difficulty translocating. However, when mutant ϕ clamp (F427A) channels were tested, the HBS peptide translocated normally. Overall, peptide translocation is defined by dynamic interactions between the peptide and ϕ clamp. These dynamics require conformational flexibility, such that the peptide productively forms both extended-chain and helical states during translocation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Clamped elastic-ideally plastic beams and Prandtl-Ishlinskii hysteresis operators

    Czech Academy of Sciences Publication Activity Database

    Krejčí, Pavel; Sprekels, J.

    2008-01-01

    Roč. 1, č. 2 (2008), s. 283-292 ISSN 1937-1632 Institutional research plan: CEZ:AV0Z10190503 Keywords : elastoplasticity * beam equation * hysteresis Subject RIV: BA - General Mathematics http://aimsciences.org/journals/pdfs.jsp?paperID=3201&mode=abstract

  9. Intrinsic thermal vibrations of suspended doubly clamped single-wall carbon nanotubes

    OpenAIRE

    Babic, B.; Furer, J.; Sahoo, S.; Farhangfar, Sh.; Schonenberger, C.

    2003-01-01

    We report the observation of thermally driven mechanical vibrations of suspended doubly clamped carbon nanotubes, grown by chemical vapor deposition (CVD). Several experimental procedures are used to suspend carbon nanotubes. The vibration is observed as a blurring in images taken with a scanning electron microscope. The measured vibration amplitudes are compared with a model based on linear continuum mechanics.

  10. J-integral analysis of heterogeneous mismatched girth welds in clamped single-edge notched tension specimens

    International Nuclear Information System (INIS)

    Hertelé, Stijn; De Waele, Wim; Verstraete, Matthias; Denys, Rudi; O'Dowd, Noel

    2014-01-01

    Flaw assessment procedures require a quantification of crack driving force, and such procedures are generally based on the assumption of weld homogeneity. However, welds generally have a heterogeneous microstructure, which will influence the crack driving force. This paper describes a stress-based methodology to assess complex heterogeneous welds using a J-based approach. Clamped single-edge notched tension specimens, representative of girth weld flaws, are analyzed and the influence of weld heterogeneity on crack driving force has been determined. The use of a modified limit load for heterogeneous welds is proposed, suitable for implementation in a ‘homogenized’ J-integral estimation scheme. It follows from an explicit modification of an existing solution for centre cracked tension specimens. The proposed solution provides a good estimate of crack driving force and any errors in the approximation may be accounted for by means of a small safety factor on load bearing capacity. - Highlights: • We present a crack driving force estimation procedure for heterogeneous welds. • The procedure is based on a ‘homogenized’ version of the EPRI equation. • Complex welds are translated into equivalent idealized mismatched welds. • The procedure is validated for clamped SE(T) specimens. • A mismatch limit load for clamped SE(T) specimens is developed

  11. High Performance ZVT with Bus Clamping Modulation Technique for Single Phase Full Bridge Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yinglai; Ayyanar, Raja

    2016-03-20

    This paper proposes a topology based on bus clamping modulation and zero-voltage-transition (ZVT) technique to realize zero-voltage-switching (ZVS) for all the main switches of the full bridge inverters, and inherent ZVS and/or ZCS for the auxiliary switches. The advantages of the strategy include significant reduction in the turn-on loss of the ZVT auxiliary switches which typically account for a major part of the total loss in other ZVT circuits, and reduction in the voltage ratings of auxiliary switches. The modulation scheme and the commutation stages are analyzed in detail. Finally, a 1kW, 500 kHz switching frequency inverter of the proposed topology using SiC MOSFETs has been built to validate the theoretical analysis. The ZVT with bus clamping modulation technique of fixed timing and adaptive timing schemes are implemented in DSP TMS320F28335 resulting in full ZVS for the main switches in the full bridge inverter. The proposed scheme can save up to 33 % of the switching loss compared with no ZVT case.

  12. Replication Clamps and Clamp Loaders

    Science.gov (United States)

    Hedglin, Mark; Kumar, Ravindra; Benkovic, Stephen J.

    2013-01-01

    To achieve the high degree of processivity required for DNA replication, DNA polymerases associate with ring-shaped sliding clamps that encircle the template DNA and slide freely along it. The closed circular structure of sliding clamps necessitates an enzyme-catalyzed mechanism, which not only opens them for assembly and closes them around DNA, but specifically targets them to sites where DNA synthesis is initiated and orients them correctly for replication. Such a feat is performed by multisubunit complexes known as clamp loaders, which use ATP to open sliding clamp rings and place them around the 3′ end of primer–template (PT) junctions. Here we discuss the structure and composition of sliding clamps and clamp loaders from the three domains of life as well as T4 bacteriophage, and provide our current understanding of the clamp-loading process. PMID:23545418

  13. Integrative modelling coupled with ion mobility mass spectrometry reveals structural features of the clamp loader in complex with single-stranded DNA binding protein.

    Science.gov (United States)

    Politis, Argyris; Park, Ah Young; Hall, Zoe; Ruotolo, Brandon T; Robinson, Carol V

    2013-11-29

    DNA polymerase III, a decameric 420-kDa assembly, simultaneously replicates both strands of the chromosome in Escherichia coli. A subassembly of this holoenzyme, the seven-subunit clamp loader complex, is responsible for loading the sliding clamp (β2) onto DNA. Here, we use structural information derived from ion mobility mass spectrometry (IM-MS) to build three-dimensional models of one form of the full clamp loader complex, γ3δδ'ψχ (254 kDa). By probing the interaction between the clamp loader and a single-stranded DNA (ssDNA) binding protein (SSB4) and by identifying two distinct conformational states, with and without ssDNA, we assemble models of ψχ-SSB4 (108 kDa) and the clamp loader-SSB4 (340 kDa) consistent with IM data. A significant increase in measured collision cross-section (~10%) of the clamp loader-SSB4 complex upon DNA binding suggests large conformational rearrangements. This DNA bound conformation represents the active state and, along with the presence of ψχ, stabilises the clamp loader-SSB4 complex. Overall, this study of a large heteromeric complex analysed by IM-MS, coupled with integrative modelling, highlights the potential of such an approach to reveal structural features of previously unknown complexes of high biological importance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Which aortic clamp strategy is better to reduce postoperative stroke and death: Single center report and a meta-analysis.

    Science.gov (United States)

    Chen, Liyu; Hua, Xiumeng; Song, Jiangping; Wang, Liqing

    2018-03-01

    Stroke is severe complication of coronary artery bypass grafting (CABG) which may be associated with clamp strategy, there are 2 strategies to clamp aorta including single aortic clamp (SAC) and partial aortic clamp (PAC). It is controversial that which clamping strategy is better to reduce the postoperative stroke and death, so this study aims to investigate which is better for reducing postoperative stroke and death within 30 days. We collected 469 patients who had on-pump CABG in Fuwai Hospital during January 2014 to July 2015. The SAC group consisted of 265 patients while the PAC group included 204 patients. We compared the 2 group patient difference. At the same time, 12 studies were identified by systematic search. The odds ratio (OR) was used as effect index to compare SAC and PAC strategy by fix-effect modeling. We also tested heterogeneity and publication bias. The primary end point of study was occurrence of postoperative stroke within 30 days of operation, the second end point of study was the incidence of 30-day mortality. The single center retrospective study showed that the patients in the SAC group were older than those in the PAC group (62.5 ± 8.1 vs 60.3 ± 8.0 years, P = .01). The proportions of peripheral vascular disease and hypertension of SAC were higher than PAC (71 (26.8%) versus 36 (17.6%), P = .02; 183 (69.1%) versus 115 (56.4%), P = .01, respectively). Besides, the number of vascular anastomosis was more in the SAC group (3.29 ± 0.74 versus 2.97 ± 0.974, P < .001). The linear-regression analysis suggested that the time of cardiopulmonary bypass of SAC was shorter than the PAC group (93.2 ± 22.4 vs.103.4 ± 26.8 minutes, P-regression < .001) and postoperative death within 30-days was similar (1 (0.4%) vs. 2 (1.0%), P-regression = .47). There was no stroke occurring in both the groups. And the meta-analysis suggested the postoperative stroke and death within 30-days were similar between

  15. Rigid clamp

    Science.gov (United States)

    Benavides, Gilbert L.; Burt, Jack D.

    1994-01-01

    The invention relates to a clamp mechanism that can be used to attach or temporarily support objects inside of tubular goods. The clamp mechanism can also be modified so that it grips objects. The clamp has a self-centering feature to accommodate out-of-roundness or other internal defections in tubular objects such as pipe. A plurality of clamping shoes are expanded by a linkage which is preferably powered by a motor to contact the inside of a pipe. The motion can be reversed and jaw elements can be connected to the linkage so as to bring the jaws together to grab an object.

  16. Clamp-mount device

    Science.gov (United States)

    Clark, K. H. (Inventor)

    1983-01-01

    A clamp-mount device is disclosed for mounting equipment to an associated I-beam and the like structural member of the type having oppositely extending flanges wherein the device comprises a base and a pair of oppositely facing clamping members carried diagonally on the base clamping flanges therebetween and having flange receiving openings facing one another. Lock means are carried diagonally by the base opposite the clamping members locking the flanges in the clamping members. A resilient hub is carried centrally of the base engaging and biasing a back side of the flanges maintaining tightly clamped and facilitating use on vertical as well as horizontal members. The base turns about the hub to receive the flanges within the clamping members. Equipment may be secured to the base by any suitable means such as bolts in openings. Slidable gate latches secure the hinged locks in an upright locking position. The resilient hub includes a recess opening formed in the base and a rubber-like pad carried in this opening being depressably and rotatably carried therein.

  17. A High-Power-Density Single-Phase Rectifier Based on Three-Level Neutral-Point Clamped Circuits

    Directory of Open Access Journals (Sweden)

    Tao Zhou

    2017-05-01

    Full Text Available A single-phase three-level converter is suitable for medium-power applications, with an interface voltage that is higher than that of a traditional two-level configuration. The three-level neutral-point clamped converter is adopted using four switches in each bridge arm, which, compared to a two-level rectifier, leads to less voltage stress, a lower switching frequency, and switching loss on switches. The transient current control strategy is designed to control the active power. The single-phase space vector pulse width modulation (SVPWM with a voltage balance strategy is designed to solve the neutral point voltage fluctuation problem and keep the dc-link voltage stable. A 1.3 kW high-power-density prototype based on SiC MOSFET was built and tested. The experimental results verified the high performance of steady-state and dynamic responses.

  18. Voltage-Sharing Converter to Supply Single-Phase Asymmetrical Four-Level Diode-Clamped Inverter With High Power Factor Loads

    DEFF Research Database (Denmark)

    Boora, Arash A.; Nami, Alireza; Zare, Firuz

    2010-01-01

    of the load is close to unity. In this paper, a new single-inductor multi-output dc/dc converter is proposed that can control the dc-link voltages of a single-phase diode-clamped inverter asymmetrically to achieve voltage quality enhancement. The circuit of the presented converter is explained and the main...

  19. Dynamic Pull-In Investigation of a Clamped-Clamped Nanoelectromechanical Beam under Ramp-Input Voltage and the Casimir Force

    Directory of Open Access Journals (Sweden)

    Amir R. Askari

    2014-01-01

    Full Text Available The influence of the Casimir excitation on dynamic pull-in instability of a nanoelectromechanical beam under ramp-input voltage is studied. The ramp-input actuation has applications in frequency sweeping of RF-N/MEMS. The presented model is nonlinear due to the inherent nonlinearity of electrostatics and the Casimir excitations as well as the geometric nonlinearity of midplane stretching. A Galerkin based reduced order modeling is utilized. It is found that the calculated dynamic pull-in ramp input voltage leads to dynamic pull-in step input voltage by increasing the slope of voltage-time diagram. This fact is utilized to verify the results of present study.

  20. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    multiple unit traction system is proposed in this study. The strategy is based on a multiple frequency tuned quasi-proportional resonant controller in the ac-side current loop and a multiple frequency tuned notch filter in the dc-link voltage loop. Under the typical supply voltage distortion present......Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...... in the network, the proposed control strategy improves the current tracking performance and reduces the line current harmonics, when compared with conventional control strategies. Experimental results, both under purely sinusoidal and distorted supply voltages, validate the effectiveness of the proposed control...

  1. Single Gradientless Light Beam Drags Particles as Tractor Beams

    DEFF Research Database (Denmark)

    Novitsky, Andrey; Qiu, Cheng-Wei; Wang, Haifeng

    2011-01-01

    is the strong nonparaxiality of the light beam, which contributes to the pulling force owing to momentum conservation. The nonparaxiality of the Bessel beam can be manipulated to possess a dragging force along both the radial longitudinal directions, i.e., a "tractor beam" with stable trajectories is achieved......Usually a light beam pushes a particle when the photons act upon it. We investigate the optical forces by nonparaxial gradientless beams and find that the forces can drag suitable particles all the way towards the light source. The major criterion of realizing the backward dragging force...

  2. Report on single beam stability - coherent effects

    International Nuclear Information System (INIS)

    Brouzet, E.; Gareyte, J.; Hofmann, A.; Laclare, J.C.; Leleux, G.; Miles, J.; Schindl, K.H.

    1980-01-01

    Group 1A was concerned with single beam stability, coherent effects. Theory is available. Most of the material for this work was drawn from F.J. Sacherer theory which has been left in reasonably good shape in the sense that given any coupling impedance, its effect on the beam can be estimated. The EBI computer program was extensively used in this respect. We still lack thorough knowledge of the SPS coupling impedance. Accordingly our results rest on a model. This model should be too unrealistic since it originates from various data of the SPS and other machines. Nevertheless any complementary information about the SPS impedance would be welcome. Broad-band impedance and parasitic effects on transverse and longitudinal motions will be reviewed. We shall mainly focus on the 270 GeV case with six equidistant bunches and 10 11 particles per bunch. For other schemes results can be obtained in a similar fashion. Some relevant figures will be given for the situation at injection. (orig.)

  3. Single-stage gain-clamped L-band EDFA with C-band ASE self-oscillation in ring cavity

    International Nuclear Information System (INIS)

    Mahdi, M A; Al-Mansoori, M H; Bakar, A A A; Shaari, S; Zamzuri, A K

    2008-01-01

    We demonstrate single-stage gain-clamped L-band Er 3+ -doped fiber amplifier (EDFA) utilizing self-oscillation modes as the control light. The amplifier structure exploits the characteristics of C/L-band coupler to isolate between lasing modes and L-band signal. The self-lasing cavity modes are obtained without any tunable bandpass filter in the loop and generated from the amplified spontaneous emission in the C-band region. The amplifier configuration has lower noise figures as opposed to a dual-stage partially gain-clamped amplifier. The gain and noise figure fluctuations are less than ± 0.4 dB in the gain-clamping region. The transient analysis confirms that the maximum power excursion is less than 0.3 dB for 10-dB add/drop

  4. Charlie's Clamp.

    Science.gov (United States)

    Tarino, Janet Z.

    1998-01-01

    Presents a version of the crush-the-can demonstration which is a hands-on activity in which students use an inexpensive, easily made holder for the can called Charlie's clamp. Includes some suggestions for the follow-up discussion. (DDR)

  5. Relationship between external ventricular drain clamp trials and ventriculoperitoneal shunt insertion following nontraumatic subarachnoid hemorrhage: a single-center study.

    Science.gov (United States)

    Ascanio, Luis C; Gupta, Raghav; Adeeb, Nimer; Moore, Justin M; Griessenauer, Christoph J; Mayeku, Julie; Tachie-Baffour, Yaw; Thomas, Ranjit; Alturki, Abdulrahman Y; Schmalz, Philip G R; Ogilvy, Christopher S; Thomas, Ajith J

    2018-03-16

    OBJECTIVE Currently, there is no established standard regarding the ideal number of external ventricular drain (EVD) clamp trials performed before ventriculoperitoneal (VP) shunt insertion following nontraumatic subarachnoid hemorrhage (SAH). In this study, the authors aimed to evaluate this relationship. METHODS A retrospective review of all patients presenting with SAH between July 2007 and December 2016 was performed. Patients with SAH who had received an EVD within the first 24 hours of hospital admission and had undergone at least 1 clamp trial prior to EVD removal were eligible for inclusion in the study. Patient demographics, clinical presentations, SAH etiologies and grades, clamp trial data, hospital lengths of stay, and functional outcomes were recorded. RESULTS One hundred fourteen patients with nontraumatic SAH complicated by posthemorrhagic hydrocephalus were included in the study. The median patient age was 57 years (range 28-90 years), with a male/female ratio of 1:1.7. A ruptured aneurysm was the underlying etiology of SAH in 79.8% of patients. A majority of patients (69.4%) had a Hunt and Hess grade III-V on admission. The median number of clamp trials performed was 2 (range 1-6). A VP shunt was required in 40.4% of patients. In those who underwent 2 and 3 clamp trials, 60% and 38.9%, respectively, did not require subsequent VP shunt placement. CONCLUSIONS Surgical placement of a VP shunt is associated with complications. Clamp trials are routinely performed before making the decision to insert a shunt. In the present study, the authors found that a significant percentage of patients passed their second and third clamp trials without requiring subsequent shunt insertion. These data support performing multiple clamp trials prior to shunt placement.

  6. The single-beam funnel demonstration: Experiment and simulation

    International Nuclear Information System (INIS)

    Johnson, K.F.; Sander, O.R.; Bolme, G.O.; Gilpatrick, J.D.; Guy, F.W.; Marquardt, J.H.; Sandoval, D.; Yuan, V.; Saadatmand, K.

    1991-01-01

    Accelerator concepts for heavy-ion fusion and for the transmutation of nuclear waste require small-emittance, high-current beams. Such applications include funnels in which high-current, like-charged particle beams are interlaced to double the beam current. The first experimental demonstration confirming the beam dynamics of the funnel principle (with contained emittance growth) was recently completed at Los Alamos National Laboratory. A single leg of a prototype 5-MeV, H - funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. The experiment contained elements for emittance control, position control, and rf-deflection. Diagnostics allowed measurement of beam intensity, position and angle centroids, energy and phase centroids, transverse and longitudinal phase-space distributions. Results of the experiment will be presented along with comparisons to simulations

  7. Design of a multi beam klystron cavity from its single beam parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Deepender, E-mail: dkc@ceeri.ernet.in; Joshi, L. M. [CSIR-Central Electronics Engineering Research Institute, Pilani (India); Janyani, Vijay [Department of ECE, MNIT, Jaipur (India)

    2016-03-09

    The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

  8. Single-particle beam dynamics in Boomerang

    International Nuclear Information System (INIS)

    Jackson, Alan; Nishimura, Hiroshi

    2003-01-01

    We describe simulations of the beam dynamics in the storage ring (Boomerang), a 3-GeV third-generation light source being designed for the Australian Synchrotron Project[1]. The simulations were performed with the code Goemon[2]. They form the basis for design specifications for storage ring components (apertures, alignment tolerances, magnet quality, etc.), and for determining performance characteristics such as coupling and beam lifetime

  9. del Nido versus St. Thomas Cardioplegia Solutions: A Single-Center Retrospective Analysis of Post Cross-Clamp Defibrillation Rates.

    Science.gov (United States)

    Buel, Shane T; Striker, Carrie Whittaker; O'Brien, James E

    2016-06-01

    There are many cardioplegia solutions currently in use for pediatric cardiopulmonary bypass (CPB). The most common being del Nido solution. Another common cardioplegia solution used for pediatric CPB is St. Thomas. In October 2014, Children's Mercy Kansas City changed from the use of modified St. Thomas to del Nido. This study compared rates of post cross-clamp fibrillation requiring defibrillation between del Nido solution and modified St. Thomas solution stratified by weight at Children's Mercy Kansas City. This retrospective study consisted of 394 patients who underwent cardiac surgery requiring cardioplegia between January 1, 2014 and July 31, 2015. The outcome measured was defibrillation upon cross-clamp removal. Statistical significance was determined using Fishers exact test with a two-sided significance level of .05. Incidence of defibrillation post cross-clamp removal was 4.4% in the del Nido group and 26.8% in the St. Thomas group (p Thomas group (p Thomas group (p Thomas group (p 60-kg category had an incidence of defibrillation of 16.7% in the del Nido group and 63% in the St. Thomas group (p Thomas and del Nido cardioplegia solutions. Analyses of weight stratifications demonstrate a decrease in the rate of defibrillation post cross-clamp removal in all categories within the del Nido group.

  10. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago

    2012-01-01

    This letter introduces a new series of multilevel (ML) converters based on the ML clamping concept. By applying this technique, a ML clamping unit (MCU) conveys additional levels for synthesizing the output waveforms of a diode-clampedML dc– ac power converter. The basic building block of the ML...... clamping scheme is the ML clamping cell, which is composed of a pair of dc sources associated with one single-pole/triple-throw type of switch arrangement. The number of series-connected ML-clamping cells will set the number of levels of the synthesized waveform. By depending on the MCU arrangements......, different converter configurations can be derived, namely, the common clamping and the modular types. Both approaches can be accomplished by employing classical three-level neutral-point-clamped (NPC) technology. Thus, the overall structure of the resultant converter is kept simple, wherein the number...

  11. Single-electrode monitors for relativistic intense electron beam parameters

    International Nuclear Information System (INIS)

    Stratienko, V.A.; Khorenko, V.K.

    1977-01-01

    A single-electrode monitor operating in atmosphere on delta-electrons for precision measurement of high-intensity electron beams is developed. As an emitter is used a 0.2 mm aluminium foil with a hole which is a replica of the sample subjected to radiation. The electric charge from the emitter is recorded by a current integrator. The single-electrode monitor enabled to form a 225 MeV electron beam with a flux density of 5x10 15 electrons/ (cm 2 and confine the latter for 140 hours with an accuracy of +- 0.2 mm. Controlling the beam shifting by means of the single-electrode monitor described, it is possible to measure the real dimensions and density distributions of high-intensity electron beams

  12. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki

    2014-05-22

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  13. Single variable refined beam theories for the bending, buckling and free vibration of homogenous beams

    Directory of Open Access Journals (Sweden)

    Sayyad A. S.

    2016-12-01

    Full Text Available In this paper, single variable beam theories taking into account effect of transverse shear deformation are developed and applied for the bending, buckling and free vibration analysis of thick isotropic beams. The most important feature of the present beam theories is that unlike any other higher order theory, the proposed class of theories contains only one unknown variable and does not require shear correction factor. The displacement field of the present theories is built upon the classical beam theory. The theories account for parabolic distribution of transverse shear stress using constitutive relations, satisfying the traction free conditions at top and bottom surfaces of the beam. Governing differential equation and boundary conditions of these theories are obtained using the principle of virtual work. Results obtained for the displacements, stresses, fundamental frequencies and critical buckling loads of simply supported isotropic solid beams are compared with those obtained by other theories to validate the accuracy of the present theories.

  14. Clamp usable as jig and lifting clamp

    Science.gov (United States)

    Tsuyama, Yoshizo

    1976-01-01

    There is provided a clamp which is well suited for use as a lifting clamp for lifting and moving materials of assembly in a shipyard, etc. and as a pulling jig in welding and other operations. The clamp comprises a clamp body including a shackle for engagement with a pulling device and a slot for receiving an article, and a pair of jaws provided on the leg portions of the clamp body on the opposite sides of the slot to grip the article in the slot, one of said jaws consisting of a screw rod and the other jaw consisting of a swivel jaw with a spherical surface, whereby when the article clamped in the slot by the pair of jaws tends to slide in any direction with respect to the clamp body, the article is more positively gripped by the pair of jaws.

  15. Beam-dynamics design and performance of the rf deflector in the Los Alamos single-beam funnel experiment

    International Nuclear Information System (INIS)

    Guy, F.W.; Johnson, K.F.; Sander, O.R.

    1991-01-01

    Funnels in which two bunched ion beams are interlaced to form a single beam have been proposed for high-current low-emittance ion linacs. A well-designed funnel would produce a beam with twice the frequency and current and almost twice the brightness of each original beam. A single-beam funnel experiment exploring the beam- dynamics and physics issues of a discrete-element future has been completed at Los Alamos National Laboratory (LANL). The only known beam-dynamics issue of concern in a two-beam funnel not addressed was the beam-beam interaction, which is negligible. The rf deflector, in which beam merging occurs, is a key component of a discrete-element funnel. We report the beam-dynamics design procedure and experimental results for the rf deflector. 8 refs., 5 figs

  16. Comparison of Multi-Beam and Single-Beam Cytofluorometers for an Automated Screening System in Gynecologic Cytology

    Science.gov (United States)

    Fujii, Ken-ichi; Suzuki, Norihito

    1983-09-01

    Clumps of cells often give a false nuclear fluorescence intensity in a measuring system using flow cytofluorometry. In this study, we examined signal selection procedures in multi-beam and single-beam cytofluorometers with the aim of eliminating such false signals. The signal selection in the multi-beam cytofluorometer was found to be far superior to that in a single-beam cytofluorometer, and the problem of false nuclear fluorescence intensity is effectively obviated by using the former type of cytofluarometer.

  17. Nonlinear beam mechanics

    NARCIS (Netherlands)

    Westra, H.J.R.

    2012-01-01

    In this Thesis, nonlinear dynamics and nonlinear interactions are studied from a micromechanical point of view. Single and doubly clamped beams are used as model systems where nonlinearity plays an important role. The nonlinearity also gives rise to rich dynamic behavior with phenomena like

  18. Quick-attach clamp

    Science.gov (United States)

    Vano, A. E.

    1968-01-01

    Clamp of the slideable jaw type can be applied to moving lines such as cables or ropes. The clamp has a trigger-operated jaw that can be attached to a redrop parachute on a moving tow cable. The trigger mechanism maintains the jaws retracted in the housing until they are released for clamping.

  19. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham [Oakland, CA; Miros, Robert H. J. [Fairfax, CA; Brown, Malcolm P [San Francisco, CA; Stancel, Robert [Loss Altos Hills, CA

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  20. Loading dynamics of a sliding DNA clamp.

    Science.gov (United States)

    Cho, Won-Ki; Jergic, Slobodan; Kim, Daehyung; Dixon, Nicholas E; Lee, Jong-Bong

    2014-06-23

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction. © 2014 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

  1. Transistor Clamped Five-Level Inverter using Non-Inverting Double Reference Single Carrier PWM Technique for photovoltaic applications

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar; Fedák, Viliam

    2017-01-01

    supplies or capacitor banks. To design the proposed five level inverter five numbers of power control switches and eight diodes are required. The proposed inverter circuitry is investigated by using Non-Inverting Double Reference Single Carrier PWM (NIDRSC PWM) Technique in terms of harmonics content...

  2. MD1228: Validation of Single Bunch Stability Threshold & MD1751: Instability Studies with a Single Beam

    CERN Document Server

    Carver, Lee Robert; Biancacci, Nicolo; Buffat, Xavier; Iadarola, Giovanni; Lasocha, Kacper; Li, Kevin Shing Bruce; Levens, Tom; Metral, Elias; Salvant, Benoit; Tambasco, Claudia; CERN. Geneva. ATS Department

    2017-01-01

    Instabilities were being routinely observed in B1V during ADJUST. The timing of the instabilities has been localised to shortly after the TOTEM bump has been implemented. The result is emittance blowup which can negatively effect the luminosity output of the fill. This MD aimed to rule out possible sources of the instability (i.e. beam-beam effects or electron cloud) by only taking one single beam to 6.5TeV and going through the full machine cycle. After the implementation of the TOTEM bump, a reduction of the octupole current was performed in order to determine if there was a discrepancy in the threshold between simulations and measurement. As a precursor, the results of the End of Fill MD: Validation of Single Bunch Stability Threshold will also be described.

  3. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized

  4. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. 5 refs

  5. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  6. The Single Pass RF Driver: Final beam compression

    International Nuclear Information System (INIS)

    Burke, Robert

    2014-01-01

    The Single Pass RF Driver (SPRFD) compacts the beam from the linac without storage rings by manipulations that take advantage of the multiplicity of isotopes (16), the preserved µbunch structure, and increased total linac current. Magnetic switches on a first set of delay lines rearrange the internal structure of the various isotopic beams. A second set of delay lines sets the relative timing of the 16 isotopic beam sections so they will telescope at the pellet, in one of multiple fusion chambers, e.g. 10. Shortening each isotopic beam section uses preservation of the µbunch structure up to the final ∼2 km drift before final focus. Just before the final drift, differential acceleration of the µbunches in each isotopic beam section (128 total) launches an axial collapse, referred to as the “Slick”. The µbunches interpenetrate as their centers of mass move toward each other and individual µbunches lengthen due to their momentum spread. In longitudinal phase space they slide over one another as they lengthen in time and slim down in instantaneous energy spread. The permissible amount of µbunch lengthening is set by the design pulse shape at the pellet, which varies for different groups of isotopes. In narrow bands of ranges according to the role for each isotope group in the pellet, the ranges extend from 1 to 10 g/cm 2 to drive the cylinder barrel and thin hemispherical end caps, to heat the ∼0.5 g/cm 2 ρR fast ignition zone, and to improve the quasi-sphericity of the compression of the fast ignition zones at the pellet's ends. Because the µbunch–µbunch momentum differences are correlated, time-ramped beamline transport elements close after the differential accelerator are used to correct the associated shifts of focal point. Beam neutralization is needed after the differential acceleration until adjacent bunches begin to overlap. Concurrent collapse of each isotope and telescoping of the 16 isotopes cause the current in each beamline to rise

  7. Trapezoidal diffraction grating beam splitters in single crystal diamond

    Science.gov (United States)

    Kiss, Marcell; Graziosi, Teodoro; Quack, Niels

    2018-02-01

    Single Crystal Diamond has been recognized as a prime material for optical components in high power applications due to low absorption and high thermal conductivity. However, diamond microstructuring remains challenging. Here, we report on the fabrication and characterization of optical diffraction gratings exhibiting a symmetric trapezoidal profile etched into a single crystal diamond substrate. The optimized grating geometry diffracts the transmitted optical power into precisely defined proportions, performing as an effective beam splitter. We fabricate our gratings in commercially available single crystal CVD diamond plates (2.6mm x 2.6mm x 0.3mm). Using a sputter deposited hard mask and patterning by contact lithography, the diamond is etched in an inductively coupled oxygen plasma with zero platen power. The etch process effectively reveals the characteristic {111} diamond crystal planes, creating a precisely defined angled (54.7°) profile. SEM and AFM measurements of the fabricated gratings evidence the trapezoidal shape with a pitch of 3.82μm, depth of 170 nm and duty cycle of 35.5%. Optical characterization is performed in transmission using a 650nm laser source perpendicular to the sample. The recorded transmitted optical power as function of detector rotation angle shows a distribution of 21.1% in the 0th order and 23.6% in each +/-1st order (16.1% reflected, 16.6% in higher orders). To our knowledge, this is the first demonstration of diffraction gratings with trapezoidal profile in single crystal diamond. The fabrication process will enable beam splitter gratings of custom defined optical power distribution profiles, while antireflection coatings can increase the efficiency.

  8. Clamp Restrains Pressure Line

    Science.gov (United States)

    Aliberti, J. A.

    1982-01-01

    Safety restraint protects people and property if a high-pressure fitting fails. As long as pressure line remains attached at the fitting, clamp exerts essentially no force on hose. If fitting fails, force of fluid leaving free end of hose causes the cam on the clamp to compress hose with a positive locking action.

  9. Quick action clamp

    Science.gov (United States)

    Calco, Frank S. (Inventor)

    1991-01-01

    A quick release toggle clamp that utilizes a spring that requires a deliberate positive action for disengagement is presented. The clamp has a sliding bolt that provides a latching mechanism. The bolt is moved by a handle that tends to remain in an engaged position while under tension.

  10. Broadening of electron beams through a single glass macrocapillary

    International Nuclear Information System (INIS)

    Bereczky, R.J.; Toekesi, K.; Dassanayake, B.S.; Tanis, J.A.

    2011-01-01

    Complete text of publication follows. The interaction of charged particles with insulating capillaries has motivated the development of nanotechnology. The interaction of slow (few keV) highly charged ions (HCI) with several kinds of insulating capillaries has been studied recently, experimentally and theoretically. These studies have shown that a considerable fraction of the ions are transmitted through the nanocapillary without close collisions with the inner wall. Moreover, the transmission of slow negative ions through insulating nanocapillary foils shows that these ions can also be guided through nanocapillaries. Studies also include faster electrons transmitting through Al 2 O 3 nanocapillaries, polyethylene terephthalate (PET) nanocapillaries, and a single glass macrocapillary. Results for electrons (200 to 350 eV) through highly ordered insulating Al 2 O 3 nanocapillaries with a large aspect ratio of 100 show evidence of guiding. Even faster electrons (500 and 1000 eV) show guiding through PET capillaries with considerable energy loss increasing with tilt angle due to inelastic scattering with the inner surface of the capillary. For the single glass macrocapillary, the transmitted electrons are found to lose energy for the same reason. Guiding is also achieved with the single glass macrocapillary for slow highly-charged ions, but no energy loss is seen. Single glass capillaries have been applied with the intention of producing submicrometer sized beams that can be used for surface modification or to selectively damage the structure of biological cells. We investigated the broadening of electron beams when traveling through an insulating single cylindrically-shaped glass capillary of macroscopic dimensions. Glass capillary samples (diameters d = 0.18 and 0.23 mm and lengths l = 14.4 and 16.8 mm) made of Borosilicate glass were subjected to bombardment by ∼500 eV electrons. Defocusing effects have also been observed in most of the electron transmission

  11. DC proton beam measurements in a single-solenoid low-energy beam transport system

    International Nuclear Information System (INIS)

    Stevens, R.R. Jr.; Schafstall, P.; Schneider, J.D.; Sherman, J.; Zaugg, T.; Taylor, T.

    1994-01-01

    High current, CW proton accelerators are being considered for a number of applications including disposition of nuclear wastes, reduction of fissionable nuclear material inventories, safe production of critical nuclear materials, and energy production. All these applications require the development of high current, reliable, hydrogen ion injectors. In 1986, a program using CW RFQ technology was undertaken at CRL in collaboration with LANL and was continued there until 1993. During this time, an accelerator was built which produced 600 keV, 75 mA and 1,250 keV, 55 mA CW proton beams. The present program at Los Alamos using this accelerator is aimed at continuing the CRL work to demonstrate long-term reliability. In the present work, the authors are seeking to determine the optimal match to and the current limit of the 1,250-keV RFQ. This paper discusses the characterization of the 50 keV beams at the exit of the single-solenoid LEBT and presents both the experimental measurements and the beam simulations done to model this system

  12. Detection of hybridization of single-strand DNA PCR products in temperature change process by a novel metal-clamping piezoelectric sensor.

    Science.gov (United States)

    Chen, Qinghai; Bian, Zhiheng; Hua, Xing; Yao, Chunyan; Wu, Wei; Zhang, Xue; Zhang, Bo; Huang, Junfu; Tang, Wanli; Fu, Weiling

    2010-05-15

    Oligonucleotide probes on the sensor surface can be hybridized with single-strand DNA (ssDNA) that is formed from PCR products in ice bath after degeneration. Thus, detection of PCR products by piezoelectric sensors requires the participation of ssDNA PCR products in ice bath. When PCR products in ice bath are added into the buffer of the sensor well at room temperature, there will be a temperature change process during mixing. However, it still remains unclear whether the temperature change affects the frequency baseline stability of the sensor and the result judgment, which is the basic condition for detecting hybridization of nucleic acid. In this study, we detected the hybridization of HPV PCR products during temperature change process by a self-designed adjustable metal-clamping piezoelectric sensor. The study mainly involves sensor adjustment, probe immobilization and ice bath sample addition (at different concentrations and different volumes). The response curve of basic frequency in temperature change process showed three stages, i.e., increase, decrease to baseline, and continuous decrease to stability. The early increase of frequency and duration of the time can reach 55+/-7.4 Hz and 39 min when 40 microL sample (0-1 degrees C) was added into 110 microL buffer (25 degrees C). The frequency increase effect caused by temperature difference at early stage depends on the volume ratio of two liquids and on the temperature difference. The results indicate that we should pay more attention to possibly small volume of PCR products in ice bath and minor temperature difference of two liquids in operation. 2010 Elsevier B.V. All rights reserved.

  13. Measuring charge density of electron beam single nanosecond pulses

    International Nuclear Information System (INIS)

    Gonchar, A.I.; Nesterenko, V.S.; Fazkullin, V.A.

    1982-01-01

    A description is presented of a probe design and electrometric repeater circuit and technique for measuring the charge (current) density of electron beam single pulses by integrating current at a reference capacitor with a subsequent registering of voltage across the capacitor. The probe consists of a band-type signal electrodes and two oval cross-section sleeves: external and internal with larger and smaller rectangular openings, respectively. The external sleeve has antidynatron grid located over the hole. The design employs integer nickel sleever - the cores of electron tube cathodes. The signal electrode is made of nickel band 0.15 mm thick. The probe elements are insulated from each other along the whole length with a layer of teflon band (30 μm), with rectangular openings cut in compliance with the sleeve openings. The measurement range is from 0.4x10 - 9 to 1x10 - 7 C/cm 2 . The rated accuracy of measurements is no worse than +-5% for the beam energy of 0.2 to 3 KeV. The ultimate parameters the charge density - 6 C/cm 2 and direct current density 3 mA/cm 2 - are specified by the breakdown voltage (200 V) of the input capacitor and probe insulation

  14. Single bunch beam breakup in linacs and BNS damping

    International Nuclear Information System (INIS)

    Toyomasu, Takanori

    1991-12-01

    We study a single-bunch beam breakup (BBU) problem by a macro-particle model. We consider both the BBU solution and the Landau damping solution which includes the Balakin-Novokhatsky-Smirnov (BNS) damping. In the BBU solution, we get an analytic solution which includes both the Chao-Richter-Yao solution and the two-particle model solution and which agrees well with simulation. The solution can also be used in a multi-bunch case. In the Landau damping solution, we can be see the mechanism of Landau damping formally and can get some insights into BNS damping. We confirm that a two-particle model criterion for BNS damping is a good one. We expect that the two-particle model criterion is represented by the first order interaction in Landau damping solution of a macro-particle model. (author)

  15. Underwater Environment SDAP Method Using Multi Single-Beam Sonars

    Directory of Open Access Journals (Sweden)

    Zheping Yan

    2013-01-01

    Full Text Available A new autopilot system for unmanned underwater vehicle (UUV using multi-single-beam sonars is proposed for environmental exploration. The proposed autopilot system is known as simultaneous detection and patrolling (SDAP, which addresses two fundamental challenges: autonomous guidance and control. Autonomous guidance, autonomous path planning, and target tracking are based on the desired reference path which is reconstructed from the sonar data collected from the environmental contour with the predefined safety distance. The reference path is first estimated by using a support vector clustering inertia method and then refined by Bézier curves in order to satisfy the inertia property of the UUV. Differential geometry feedback linearization method is used to guide the vehicle entering into the predefined path while finite predictive stable inversion control algorithm is employed for autonomous target approaching. The experimental results from sea trials have demonstrated that the proposed system can provide satisfactory performance implying its great potential for future underwater exploration tasks.

  16. Ion beam synthesis of buried single crystal erbium silicide

    International Nuclear Information System (INIS)

    Golanski, A.; Feenstra, R.; Galloway, M.D.; Park, J.L.; Pennycook, S.J.; Harmon, H.E.; White, C.W.

    1990-01-01

    High doses (10 16 --10 17 /cm 2 ) of 170 keV Er + were implanted into single-crystal left-angle 111 right-angle Si at implantation temperatures between 350 degree C and 520 degree C. Annealing at 800 degree C in vacuum following the implant, the growth and coalescence of ErSi 2 precipitates leads to a buried single crystalline ErSi 2 layer. This has been studied using Rutherford backscattering/channeling, X-ray diffraction, cross-sectional TEM and resistance versus temperature measurements. Samples implanted at 520 degree C using an Er dose of 7 x 10 16 /cm 2 and thermally annealed were subsequently used as seeds for the mesoepitaxial growth of the buried layer during a second implantation and annealing process. Growth occurs meso-epitaxially along both interfaces through beam induced, defect mediated mobility of Er atoms. The crystalline quality of the ErSi 2 layer strongly depends on the temperature during the second implantation. 12 refs., 4 figs

  17. Mechanism of opening a sliding clamp

    OpenAIRE

    Douma, Lauren G.; Yu, Kevin K.; England, Jennifer K.; Levitus, Marcia; Bloom, Linda B.

    2017-01-01

    Abstract Clamp loaders load ring-shaped sliding clamps onto DNA where the clamps serve as processivity factors for DNA polymerases. In the first stage of clamp loading, clamp loaders bind and stabilize clamps in an open conformation, and in the second stage, clamp loaders place the open clamps around DNA so that the clamps encircle DNA. Here, the mechanism of the initial clamp opening stage is investigated. Mutations were introduced into the Escherichia coli β-sliding clamp that destabilize t...

  18. Bend-absorbing clamp

    Science.gov (United States)

    Abbott, J. R.; Valencia, B., Jr.

    1979-01-01

    Compact, inexpensive clamp for flexible cables or rigid tubes absorbs vibrations and other motion. It accomodates wide range of dimensions, and saves space by eliminating pigtails or bellows commonly used to absorb linear movement or vibrations

  19. How a DNA polymerase clamp loader opens a sliding clamp

    OpenAIRE

    Kelch, Brian A.; Makino, Debora L.; O’Donnell, Mike; Kuriyan, John

    2011-01-01

    Processive chromosomal replication relies on sliding DNA clamps, which are loaded onto DNA by pentameric clamp loader complexes belonging to the AAA+ family of ATPases. We present structures for the ATP-bound state of the clamp loader complex from bacteriophage T4, bound to an open clamp and primer-template DNA. The clamp loader traps a spiral conformation of the open clamp so that both the loader and the clamp match the helical symmetry of DNA. One structure reveals that ATP has been hydroly...

  20. How a DNA polymerase clamp loader opens a sliding clamp

    Science.gov (United States)

    Kelch, Brian A.; Makino, Debora L.; O’Donnell, Mike; Kuriyan, John

    2012-01-01

    Processive chromosomal replication relies on sliding DNA clamps, which are loaded onto DNA by pentameric clamp loader complexes belonging to the AAA+ family of ATPases. We present structures for the ATP-bound state of the clamp loader complex from bacteriophage T4, bound to an open clamp and primer-template DNA. The clamp loader traps a spiral conformation of the open clamp so that both the loader and the clamp match the helical symmetry of DNA. One structure reveals that ATP has been hydrolyzed in one subunit, and suggests that clamp closure and ejection of the loader involves disruption of the ATP-dependent match in symmetry. The structures explain how synergy between the loader, the clamp and DNA can trigger ATP hydrolysis and release of the closed clamp on DNA. PMID:22194570

  1. Integrated single- and two-photon light sheet microscopy using accelerating beams

    DEFF Research Database (Denmark)

    Piksarv, Peeter; Marti, Dominik; Le, Tuan

    2017-01-01

    We demonstrate the first light sheet microscope using propagation invariant, accelerating Airy beams that operates both in single- and two-photon modes. The use of the Airy beam permits us to develop an ultra compact, high resolution light sheet system without beam scanning. In two-photon mode, a...

  2. Single photon emission computed tomography by using fan beam collimator

    International Nuclear Information System (INIS)

    Akiyama, Yoshihisa

    1992-01-01

    A multislice fan beam collimator which has parallel collimation along the cephalic-caudul axis of a patient and converging collimation within planes that are perpendicular to that axis was designed for a SPECT system with a rotating scintillation camera, and it was constructed by the lead casting method which was developed in recent years. A reconstruction algorithm for fan beam SPECT was formed originally by combining the reconstruction algorithm of the parallel beam SPECT with that of the fan beam X-ray CT. The algorithm for fan beam SPECT was confirmed by means of computer simulation and a head phantom filled with diluted radionuclide. Not only 99m Tc but also 123 I was used as a radionuclide. A SPECT image with the fan beam collimator was compared with that of a parallel hole, low energy, high resolution collimator which was routinely used for clinical and research SPECT studies. Both system resolution and sensitivity of the fan beam collimator were ∼20% better than those of the parallel hole collimator. Comparing SPECT images obtained from fan beam collimator with those of parallel hole collimator, the SPECT images using fan beam collimator had far better resolution. A fan beam collimator is a useful implement for the SPECT study. (author)

  3. Laser Induced Breakdown Spectroscopy Based on Single Beam Splitting and Geometric Configuration for Effective Signal Enhancement

    OpenAIRE

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-01

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS)...

  4. Optimisation of sonourethrography: the clamp method.

    Science.gov (United States)

    Berná-Mestre, Juan de Dios; Balmaceda, Thierry; Martínez, Diego; Escudero, Jose F; Martínez, Gloria; García, José A; Canteras, Manuel; Berná-Serna, Juan D

    2018-05-01

    To describe the clamp method for performing retrograde sonourethrography (RSUG) and contrast-enhanced voiding sonourethrography (CE-VSUG) via the transperineal approach in male adults. Prospective study of 113 males (14-86 years) with urethral strictures confirmed by urethrography who received sonourethrography via the clamp method between 2011 and 2015. The characteristic parameters of the quantitative variables were calculated and a comparative analysis of the qualitative variables was conducted using the McNemar test. RSUG was performed successfully in all the cases (n = 113) and detected 49 cases with anterior urethral strictures; the strictures in the proximal bulbar cone in five of them (10.2%) were not visualised on retrograde urethrography (RUG) (p clamp method enables RSUG and CE-VSUG to be performed simply, effectively and painlessly by a single operator. It also allows the evaluation of cases with urethromeatal alterations (stricture, hypospadias and meatotomy). • The clamp method enables RSUG to be performed simply and painlessly. • The clamp method requires only one operator and allows assessing urethromeatal alterations. • RSUG shows greater capacity for detecting anterior urethral strictures than RUG. • The clamp method achieves retrograde bladder filling in approximately 6 min. • CE-VSUG shows greater capacity for detecting strictures than VCUG.

  5. Clamp for detonating fuze

    Science.gov (United States)

    Holderman, E. J.

    1968-01-01

    Quick acting clamp provides physical support for a closely confined detonating fuse in an application requiring removal and replacement at frequent intervals during test. It can be designed with a base of any required strength and configuration to permit the insertion of an object.

  6. Vibrations and stability of complex beam systems

    CERN Document Server

    Stojanović, Vladimir

    2015-01-01

     This book reports on solved problems concerning vibrations and stability of complex beam systems. The complexity of a system is considered from two points of view: the complexity originating from the nature of the structure, in the case of two or more elastically connected beams; and the complexity derived from the dynamic behavior of the system, in the case of a damaged single beam, resulting from the harm done to its simple structure. Furthermore, the book describes the analytical derivation of equations of two or more elastically connected beams, using four different theories (Euler, Rayleigh, Timoshenko and Reddy-Bickford). It also reports on a new, improved p-version of the finite element method for geometrically nonlinear vibrations. The new method provides more accurate approximations of solutions, while also allowing us to analyze geometrically nonlinear vibrations. The book describes the appearance of longitudinal vibrations of damaged clamped-clamped beams as a result of discontinuity (damage). It...

  7. The ATP Sites of AAA+ Clamp Loaders Work Together as a Switch to Assemble Clamps on DNA*

    Science.gov (United States)

    Marzahn, Melissa R.; Hayner, Jaclyn N.; Finkelstein, Jeff; O'Donnell, Mike; Bloom, Linda B.

    2014-01-01

    Clamp loaders belong to a family of proteins known as ATPases associated with various cellular activities (AAA+). These proteins utilize the energy from ATP binding and hydrolysis to perform cellular functions. The clamp loader is required to load the clamp onto DNA for use by DNA polymerases to increase processivity. ATP binding and hydrolysis are coordinated by several key residues, including a conserved Lys located within the Walker A motif (or P-loop). This residue is required for each subunit to bind ATP. The specific function of each ATP molecule bound to the Saccharomyces cerevisiae clamp loader is unknown. A series of point mutants, each lacking a single Walker A Lys residue, was generated to study the effects of abolishing ATP binding in individual clamp loader subunits. A variety of biochemical assays were used to analyze the function of ATP binding during discrete steps of the clamp loading reaction. All mutants reduced clamp binding/opening to different degrees. Decreased clamp binding activity was generally correlated with decreases in the population of open clamps, suggesting that differences in the binding affinities of Walker A mutants stem from differences in stabilization of proliferating cell nuclear antigen in an open conformation. Walker A mutations had a smaller effect on DNA binding than clamp binding/opening. Our data do not support a model in which each ATP site functions independently to regulate a different step in the clamp loading cycle to coordinate these steps. Instead, the ATP sites work in unison to promote conformational changes in the clamp loader that drive clamp loading. PMID:24436332

  8. The ATP sites of AAA+ clamp loaders work together as a switch to assemble clamps on DNA.

    Science.gov (United States)

    Marzahn, Melissa R; Hayner, Jaclyn N; Finkelstein, Jeff; O'Donnell, Mike; Bloom, Linda B

    2014-02-28

    Clamp loaders belong to a family of proteins known as ATPases associated with various cellular activities (AAA+). These proteins utilize the energy from ATP binding and hydrolysis to perform cellular functions. The clamp loader is required to load the clamp onto DNA for use by DNA polymerases to increase processivity. ATP binding and hydrolysis are coordinated by several key residues, including a conserved Lys located within the Walker A motif (or P-loop). This residue is required for each subunit to bind ATP. The specific function of each ATP molecule bound to the Saccharomyces cerevisiae clamp loader is unknown. A series of point mutants, each lacking a single Walker A Lys residue, was generated to study the effects of abolishing ATP binding in individual clamp loader subunits. A variety of biochemical assays were used to analyze the function of ATP binding during discrete steps of the clamp loading reaction. All mutants reduced clamp binding/opening to different degrees. Decreased clamp binding activity was generally correlated with decreases in the population of open clamps, suggesting that differences in the binding affinities of Walker A mutants stem from differences in stabilization of proliferating cell nuclear antigen in an open conformation. Walker A mutations had a smaller effect on DNA binding than clamp binding/opening. Our data do not support a model in which each ATP site functions independently to regulate a different step in the clamp loading cycle to coordinate these steps. Instead, the ATP sites work in unison to promote conformational changes in the clamp loader that drive clamp loading.

  9. Optimization of Laser Beam Transformation Hardening by One Single Parameter

    NARCIS (Netherlands)

    Meijer, J.; van Sprang, I.

    1991-01-01

    The process of laser beam transformation hardening is principally controlled by two independent parameters, the absorbed laser power on a given area and the interaction time. These parameters can be transformed into two functional parameters: the maximum surface temperature and the hardening depth.

  10. Mechanism of opening a sliding clamp.

    Science.gov (United States)

    Douma, Lauren G; Yu, Kevin K; England, Jennifer K; Levitus, Marcia; Bloom, Linda B

    2017-09-29

    Clamp loaders load ring-shaped sliding clamps onto DNA where the clamps serve as processivity factors for DNA polymerases. In the first stage of clamp loading, clamp loaders bind and stabilize clamps in an open conformation, and in the second stage, clamp loaders place the open clamps around DNA so that the clamps encircle DNA. Here, the mechanism of the initial clamp opening stage is investigated. Mutations were introduced into the Escherichia coli β-sliding clamp that destabilize the dimer interface to determine whether the formation of an open clamp loader-clamp complex is dependent on spontaneous clamp opening events. In other work, we showed that mutation of a positively charged Arg residue at the β-dimer interface and high NaCl concentrations destabilize the clamp, but neither facilitates the formation of an open clamp loader-clamp complex in experiments presented here. Clamp opening reactions could be fit to a minimal three-step 'bind-open-lock' model in which the clamp loader binds a closed clamp, the clamp opens, and subsequent conformational rearrangements 'lock' the clamp loader-clamp complex in a stable open conformation. Our results support a model in which the E. coli clamp loader actively opens the β-sliding clamp. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. X-ray beam monitor made by thin-film CVD single-crystal diamond.

    Science.gov (United States)

    Marinelli, Marco; Milani, E; Prestopino, G; Verona, C; Verona-Rinati, G; Angelone, M; Pillon, M; Kachkanov, V; Tartoni, N; Benetti, M; Cannatà, D; Di Pietrantonio, F

    2012-11-01

    A novel beam position monitor, operated at zero bias voltage, based on high-quality chemical-vapor-deposition single-crystal Schottky diamond for use under intense synchrotron X-ray beams was fabricated and tested. The total thickness of the diamond thin-film beam monitor is about 60 µm. The diamond beam monitor was inserted in the B16 beamline of the Diamond Light Source synchrotron in Harwell (UK). The device was characterized under monochromatic high-flux X-ray beams from 6 to 20 keV and a micro-focused 10 keV beam with a spot size of approximately 2 µm × 3 µm square. Time response, linearity and position sensitivity were investigated. Device response uniformity was measured by a raster scan of the diamond surface with the micro-focused beam. Transmissivity and spectral responsivity versus beam energy were also measured, showing excellent performance of the new thin-film single-crystal diamond beam monitor.

  12. A single-beam deuteron compact accelerator for neutron generation

    International Nuclear Information System (INIS)

    Araujo, Wagner Leite; Campos, Tarcisio Passos Ribeiro de

    2011-01-01

    Portable neutron generators are devices composed by small size accelerators that produce neutrons through fusion between hydrogen isotopes. These reactions are characterized by appreciable cross section at energies at the tens of keV, which enables device portability. The project baselines follow the same physical and engineering principles of any other particle accelerators. The generator consists of a gas reservoir, apparatus for ion production, few electrodes to accelerate and focus the ion beam, and a metal hydride target where fusion reactions occur. Neutron generator applications include geophysical measurements, indus- trial process control, environmental, research, nation's security and mechanical structure analysis.This article presents a design of a compact accelerator for d-d neutron generators, describing the physical theory applied to the deuteron extraction system, and simulating the ion beam transport in the accelerator. (author)

  13. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Science.gov (United States)

    Prakrajang, K.; Jeynes, J. C. G.; Merchant, M. J.; Kirkby, K.; Kirkby, N.; Thopan, P.; Yu, L. D.

    2013-07-01

    As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  14. Single beam collective effects in FCC-ee due to beam coupling impedance

    CERN Document Server

    Belli, Eleonora; Persichelli, Serena; Zobov, Mikhail

    2016-01-01

    The Future Circular Collider study, hosted by CERN to design post-LHC particle accelerator options in a worldwide context, is focused on proton-proton high-energy and electron-positron high-luminosity frontier machines. This new accelerator complex represents a great challenge under several aspects, which involve R&D on beam dynamics and new technologies. One very critical point in this context is represented by collective effects, generated by the interaction of the beam with self-induced electromagnetic fields, called wake fields, which could produce beam instabilities, thus reducing the machines performance and limiting the maximum stored current. It is therefore very important to be able to predict these effects and to study in detail potential solutions to counteract them. In this paper the resistive wall and some other important geometrical sources of impedance for the FCC electron-positron accelerator are identified and evaluated, and their impact on the beam dynamics, which in some cases could lea...

  15. Single beam collective effects in FCC-ee due to beam coupling impedance

    CERN Document Server

    Belli, Eleonora

    2016-01-01

    The Future Circular Collider study, hosted by CERN to design post-LHC particle accelerator options in a worldwide context, is focused on proton-proton high-energy and electron-positron high-luminosity frontier machines. This new accelerator complex represents a great challenge under several aspects, which involve R&D on beam dynamics and new technologies. One very critical point in this context is represented by collective effects, generated by the interaction of the beam with self-induced electromagnetic fields, called wake fields, which could produce beam instabilities, thus reducing the machines performance and limiting the maximum stored current. It is therefore very important to be able to predict these effects and to study in detail potential solutions to counteract them. In this paper the resistive wall and some other important geometrical sources of impedance for the FCC electron-positron accelera- tor are identified and evaluated, and their impact on the beam dynamics, which in some cases could l...

  16. Correlating Anatomy and Function with Gene Expression in Individual Neurons by Combining in Vivo Labeling, Patch Clamp, and Single Cell RNA-seq

    Directory of Open Access Journals (Sweden)

    Carsten K. Pfeffer

    2017-11-01

    Full Text Available The classification of neurons into distinct types is an ongoing effort aimed at revealing and understanding the diversity of the components of the nervous system. Recently available methods allow us to determine the gene expression pattern of individual neurons in the mammalian cerebral cortex to generate powerful categorization schemes. For a thorough understanding of neuronal diversity such genetic categorization schemes need to be combined with traditional classification parameters like position, axonal projection or response properties to sensory stimulation. Here we describe a method to link the gene expression of individual neurons with their position, axonal projection, or sensory response properties. Neurons are labeled in vivo based on their anatomical or functional properties and, using patch clamp pipettes, their RNA individually harvested in vitro for RNAseq. We validate the methodology using multiple established molecularly and anatomically distinct cell populations and explore molecular differences between uncharacterized neurons in mouse visual cortex. Gene expression patterns between L5 neurons projecting to frontal or contralateral cortex are distinct while L2 neurons differing in position, projection, or function are molecularly similar. With this method we can determine the genetic expression pattern of functionally and anatomically identified individual neurons.

  17. Corpuscular Model of Two-Beam Interference and Double-Slit Experiments with Single Photons

    NARCIS (Netherlands)

    Jin, Fengping; Yuan, Shengjun; De Raedt, Hans; Michielsen, Kristel; Miyashita, Seiji

    We introduce an event-based corpuscular simulation model that reproduces the wave mechanical results of single-photon double-slit and two-beam interference experiments and (of a one-to-one copy of an experimental realization) of a single-photon interference experiment with a Fresnel biprism. The

  18. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Jeynes, J.C.G.; Merchant, M.J.; Kirkby, K.; Kirkby, N. [Surrey Ion Beam Center, Faculty of Engineering and Physical Science, University of Surrey, Guildford Surrey, GU2 7XH (United Kingdom); Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: •Recently completed nanobeam at the Surrey Ion Beam Centre was used. •3.8-MeV single and broad proton beams irradiated Chinese hamster cells. •Cell survival curves were measured and compared with 300-kV X-ray irradiation. •Single ion irradiation had a lower survival part at ultra-low dose. •It implies hypersensitivity, bystander effect and cell cycle phase of cell death. -- Abstract: As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  19. Molecular beam epitaxy of single crystal colossal magnetoresistive material

    International Nuclear Information System (INIS)

    Eckstein, J.N.; Bozovic, I.; Rzchowski, M.; O'Donnell, J.; Hinaus, B.; Onellion, M.

    1996-01-01

    The authors have grown films of (LaSr)MnO 3 (LSMO) and (LaCa)MnO 3 (LCMO) using atomic layer-by-layer molecular beam epitaxy (ALL-MBE). Depending on growth conditions, substrate lattice constant and the exact cation stoichiometry, the films are either pseudomorphic or strain relaxed. The pseudomorphic films show atomically flat surfaces, with a unit cell terrace structure that is a replica of that observed on the slightly vicinal substrates, while the strain relaxed films show bumpy surfaces correlated with a dislocation network. All films show tetragonal structure and exhibit anisotropic magnetoresistance, with a low field response, (1/R)(dR/dH) as large as 5 T -1

  20. Report on first masing and single mode locking in a prebunched beam FEM oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, M.; Eichenbaum, A.; Kleinman, H. [Tel-Aviv Univ., Ramat-Aviv (Israel)] [and others

    1995-12-31

    Radiation characteristics of a table-top free electron maser (FEM) are described in this paper. The FEM employs a prebunched electron beam and is operated as an oscillator in the low-gain collective (Raman) regime. Using electron beam prebunching single mode locking at any one of the possible oscillation modes was obtained. The electron beam is prebunched by a microwave tube section before it is injected into the wiggler. By tuning the electron beam bunching frequency, the FEM oscillation frequency can be locked to any eigen frequency of the resonant waveguide cavity which is within the frequency band of net gain of the FEM. The oscillation build up process is sped up, when the FEM operates with a prebunched electron beam, and the build-up time of radiation is shortened significantly. First measurements of masing with and without prebunching and characterization of the emitted radiation are reported.

  1. Studies of isotopic defined hydrogen beams scattering from Pd single-crystal surfaces

    International Nuclear Information System (INIS)

    Varlam, Mihai; Steflea, Dumitru

    2001-01-01

    An experimental investigation of hydrogen isotopes interaction with Pd single-crystal surface has been carried out using molecular beam technique. The energy dependence of the sticking probability and its relation with the trapping probability into the precursor state is studied by integrating the scattered angular distribution of hydrogen Isotopic defined beams from Pd (111) surface in the 40-400 K surface temperature range. The dependence has been evaluated by defining hydrogen molecular beams with different isotopic concentration - from the natural one to the 5% D/(D+H) ratio - and for different incident energies. The beam was directed onto a single-crystal Pd (111) surface. In the paper, we report the experimental results and some considerations related to it. (authors)

  2. Scintillation of lead tungstate crystal studied with single-electron beam from KUFEL

    Energy Technology Data Exchange (ETDEWEB)

    Rizwan, Mohamad, E-mail: rizwan@nucl.kyushu-u.ac.jp; Uozumi, Yusuke; Matsuo, Kazuki [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Fukuoka (Japan); Ohgaki, Hideaki; Kii, Toshiteru; Zen, Heishun [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto (Japan); Tsamalaidze, Zviadi; Evtoukhovitch, Petr; Valentin, Samoilov [Joint Institute for Nuclear Research, JINR, Joliot-Curie Str.6, Dubna (Russian Federation)

    2015-04-29

    Lead tungstate (PWO) crystal has a very fast response, high atomic density and high radiation hardness. Therefore, they are suitable to be used for high-energy nuclear data measurements under high-background circumstances. Although a good electron-ion separation with a pulse shape analysis technique is essential, scintillation pulse shapes have not been observed with electron beams of a wide energy range. A single-electron beam technique has been developed at Kyoto University Free Electron Laser (KUFEL), and electron beams of 4-38 MeV are available. During the experiments, single electron beams bombarded a PWO crystal. By using oscilloscope we observed scintillation pulses of a PWO crystal coupled with a photomultiplier tube. Measured spectra were compared with the simulation code of EGS5 to analyze scattering effects. As the result, the pulse amplitudes show good linearity and the pulse shapes are almost constant in the observed energy range.

  3. Hand-Held Power Clamp

    Science.gov (United States)

    Clancy, J. P.

    1985-01-01

    Tool furnishes large pushing or pulling forces. Device includes two clamping blocks, two clamping plates, and a motor-driven linear actuator with selflocking screw shaft. Power clamp exerts opening or closing force at push of switch. Tool approximately 1 m long. Originally designed to secure payload aboard Space Shuttle, operated with one hand to apply opening or closing force of up to 1,000 lb (4,400 N). Clamp has potential applications as end effector for industrial robots and in rescue work to push or pull wreckage with great force.

  4. Proximity effect of electron beam lithography on single-electron ...

    Indian Academy of Sciences (India)

    The electrical characteristics of the single-electron transistor were observed to be consistent with the expected behavior of electron transport through gated quantum dots, up to 150 K. The dependence of the electrical characteristics on the dot size reveals that the d oscillation follows from the Coulomb blockade by poly-Si ...

  5. Study on radiation dose in single-source and triple-source helical cone-beam scanning

    International Nuclear Information System (INIS)

    Lv Yang; Zhao Jun; Zhuang Tiange; Chen Kemin

    2008-01-01

    In this work we discuss the radiation area of helical cone-beam scanning and present the formulae to calculate the radiation dosage of single-source and triple-source helical cone-beam scanning. The results reveal that the radiation dose of triple-source helical cone-beam scanning is equal to that of single-source helical cone-beam scanning. (authors)

  6. The Escherichia coli Clamp Loader Can Actively Pry Open the β-Sliding Clamp*

    Science.gov (United States)

    Paschall, Christopher O.; Thompson, Jennifer A.; Marzahn, Melissa R.; Chiraniya, Ankita; Hayner, Jaclyn N.; O'Donnell, Mike; Robbins, Arthur H.; McKenna, Robert; Bloom, Linda B.

    2011-01-01

    Clamp loaders load ring-shaped sliding clamps onto DNA. Once loaded onto DNA, sliding clamps bind to DNA polymerases to increase the processivity of DNA synthesis. To load clamps onto DNA, an open clamp loader-clamp complex must form. An unresolved question is whether clamp loaders capture clamps that have transiently opened or whether clamp loaders bind closed clamps and actively open clamps. A simple fluorescence-based clamp opening assay was developed to address this question and to determine how ATP binding contributes to clamp opening. A direct comparison of real time binding and opening reactions revealed that the Escherichia coli γ complex binds β first and then opens the clamp. Mutation of conserved “arginine fingers” in the γ complex that interact with bound ATP decreased clamp opening activity showing that arginine fingers make an important contribution to the ATP-induced conformational changes that allow the clamp loader to pry open the clamp. PMID:21971175

  7. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model

    International Nuclear Information System (INIS)

    Jayaraman, S.

    1981-01-01

    A beam dose calculation model based on evaluation of tissue air ratios (TAR) and scatter air ratios (SAR) for cobalt-60 beams of rectangular cross section has been developed. Off-central axis fall-off of primary radiation intensity is derived by an empirical formulation involving an arctangent function with the slope of the geometrical penumbra acting as an essential constant. Central axis TAR and SAR values are assessed by semi-empirical polynomial expressions employing the two sides of the rectangular field as the bariables. The model utilises a minimum number of parametric constants and is useful for computer generation of isodose curves. The model is capable of accounting for situations where wedge filters or split field shielding blocks, are encountered. Further it could be widely applied with minor modifications to several makes of the currently available cobalt-60 units. The paper explains the model and shows examples of the results obtained in comparison with the corresponding experimentally determined dose distributions. (orig.) [de

  8. Trends in Aortic Clamp Use During Coronary Artery Bypass Surgery: The Effect of Aortic Clamping Strategies on Neurologic Outcomes

    Science.gov (United States)

    Daniel, William T.; Kilgo, Patrick; Puskas, John D.; Thourani, Vinod H.; Lattouf, Omar M.; Guyton, Robert A.; Halkos, Michael E.

    2013-01-01

    Objective The purpose of this study was to determine the impact of different clamping strategies during CABG on the incidence of postoperative stroke. Methods In this case-control study, all patients at Emory hospitals from 2002–2009 with postoperative stroke after isolated CABG (N=141) were matched 1:4 to a contemporaneous cohort of patients without postoperative stroke (N=565). Patients were matched according to the Society of Thoracic Surgeons (STS) Predicted Risk of Postoperative Stroke (PROPS), which is based on 26 variables. On- (ONCAB) and off-pump (OPCAB) patients were matched separately. Multiple logistic regression analysis with adjusted odds ratios (OR) was performed to identify operative variables associated with postoperative stroke. Results Among the ONCAB cohort, the single cross-clamp technique was associated with a decreased risk of stroke compared to the double clamp (cross clamp + partial clamp) technique (OR=0.385, p=0.044). Within the OPCAB cohort, there was no significant difference in stroke according to clamp use. Epiaortic ultrasound of the ascending aorta increased from 45.3% in 2002 to 89.4% in 2009. From 2002–2009, clamp use decreased from 97.7% of cases to 72.7%. Conclusions During ONCAB, the use of a single cross-clamp compared to the double clamp technique decreases the risk of postoperative stroke. The use of any aortic clamp has decreased and epiaortic ultrasound use has increased from 2002–2009, indicating a change in operative technique and surgeon awareness of the potential complications associated with manipulation of the aorta. PMID:23477689

  9. Nonlinear effects of a beam interacting with a single damped wave

    International Nuclear Information System (INIS)

    Stoltz, Peter H.; Cary, John R.

    2000-01-01

    A self-consistent nonlinear theory of the longitudinal dynamics of a low density beam interacting with a single damped wave is developed. In this paper, the model is applied to the coasting beam-cavity system of accelerator physics, but it also applies to beam-plasma systems and traveling wave tubes. Motivating the theory are numerical simulations showing different beam behaviors in the nonlinear regime depending on the amount of wave damping. For highly damped systems, breakoff and energy loss of a self-formed bunch from the beam is observed. This bunch breakoff and energy loss is the cause of the overshoot phenomenon of accelerator physics; furthermore this overshoot does not contradict the Keil-Schnell criterion, as the beam is far from a Gaussian distribution. An expression for the amount of cavity damping necessary for bunch breakoff is derived. Finally, using a single-particle model, an expression for the rate of energy loss of the bunch in terms of the cavity damping is derived. (c) 2000 American Institute of Physics

  10. Commissioning of the ATLAS Tile Calorimeter with Cosmic Ray and Single Beam Data

    CERN Document Server

    Okawa, H

    2008-01-01

    The commissioning of the ATLAS detector at the LHC has been the focus of an extensive program over several years, in preparation for the first LHC beams in 2008. We present a summary of cosmic ray and single beam commissioning results with the ATLAS hadronic Tile Calorimeter (TileCal). The emphasis will be on understanding the reconstruction of calorimeter data at each stage, from raw ADC counts, cell energy and timing, and high-level physics objects like clusters. Calibration of energy and timing is validated with cosmic and single beam data. Electronic noise at the cell level is studied, and the performance of calorimeter clustering is investigated. We discuss in detail the "Topological Clustering" technique which is one of the standard clustering algorithms in ATLAS.

  11. Single-Axis Three-Beam Amplitude Monopulse Antenna-Signal Processing Issues

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bickel, Douglas L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-05-01

    Typically, when three or more antenna beams along a single axis are required, the answer has been multiple antenna phase-centers, essentially a phase-monopulse system. Such systems and their design parameters are well-reported in the literature. Less appreciated is that three or more antenna beams can also be generated in an amplitude-monopulse fashion. Consequently, design guidelines and performance analysis of such antennas is somewhat under-reported in the literature. We provide discussion herein of three beams arrayed in a single axis with an amplitude-monopulse configuration. Acknowledgements The preparation of this report is the result of an unfunded research and development activity. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administ ration under contract DE-AC04-94AL85000.

  12. Studies of isotopic defined hydrogen beams scattering from Pd single-crystal surfaces

    International Nuclear Information System (INIS)

    Varlam, Mihai; Steflea, Dumitru

    1999-01-01

    An experimental investigation of hydrogen isotopes interaction with Pd single-crystal surfaces has been carried out using molecular beam technique. The energy dependence of the sticking probability and its relation with the trapping probability into the precursor state is studied by integrating the scattered angular distribution of hydrogen isotopic defined beams from Pd (111) surfaces in the 40 - 400 K surface temperature range. The dependence has been evaluated by defining hydrogen molecular beams with different isotopic concentration - from the natural one until 5% D/(D + H) and different incident energies and directed onto a single - crystal Pd (111) surface. In the paper, we report the experimental results and some considerations related to them. (authors)

  13. Composite Beam Cross-Section Analysis by a Single High-Order Element Layer

    DEFF Research Database (Denmark)

    Couturier, Philippe; Krenk, Steen

    2015-01-01

    An analysis procedure of general cross-section properties is presented. The formulation is based on the stress-strain states in the classic six equilibrium modes of a beam by considering a finite thickness slice modelled by a single layer of 3D finite elements. The theory is illustrated by applic...

  14. Theoretical comparison of optical traps created by standing wave and single beam

    Czech Academy of Sciences Publication Activity Database

    Zemánek, Pavel; Jonáš, Alexandr; Jákl, Petr; Ježek, Jan; Šerý, Mojmír; Liška, M.

    2003-01-01

    Roč. 220, 4-6 (2003), s. 401 - 412 ISSN 0030-4018 R&D Projects: GA ČR GA101/00/0974 Institutional research plan: CEZ:AV0Z2065902 Keywords : single beam trap * optical trapping * optical tweezers Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.482, year: 2003

  15. Single-crystal filters for attenuating epithermal neutrons and gamma rays in reactor beams

    DEFF Research Database (Denmark)

    Rustad, B.M.; Als-Nielsen, Jens Aage; Bahnsen, A.

    1965-01-01

    Cross section of representative samples of bismuth and quartz were measured at room and liquid nitrogen temperatures over neutron energy range of 0.0007 to 2.0 ev to obtain data for design of single-crystal 32-cm bismuth filters for attenuating fast neutrons and γ-rays in reactor beams; filters may...

  16. Production of multi-, oligo- and single-pore membranes using a continuous ion beam

    Czech Academy of Sciences Publication Activity Database

    Apel, P. Yu.; Ivanov, O.; Lizunov, N. E.; Mamonova, T. I.; Nechaev, A. N.; Olejniczak, K.; Vacík, Jiří; Dmitriev, S. N.

    2015-01-01

    Roč. 365, DEC (2015), s. 641-645 ISSN 0168-583X R&D Projects: GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : ion beam * irradiation * ion track * etching * single nanopore Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.389, year: 2015

  17. Laser induced breakdown spectroscopy based on single beam splitting and geometric configuration for effective signal enhancement.

    Science.gov (United States)

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-05

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS). In spatial configuration, the laser beam geometry plays an important role in the emission signal enhancement. Thus, an adjustable geometric configuration with variable incident angle between the two splitted laser beams was constructed for achieving maximum signal enhancement. With the optimized angles of 60° and 70° for Al and Cu atomic emission lines at 396.15 nm and 324.75 nm respectively, about 5.6- and 4.8-folds signal enhancements were achieved for aluminum alloy and copper alloy samples compared to SP-LIBS. Furthermore, the temporal analysis, in which the intensity of atomic lines in SP-LIBS decayed at least ten times faster than the SBS-LIBS, proved that the energy coupling efficiency of SBS-LIBS was significantly higher than that of SP-LIBS.

  18. Laser Induced Breakdown Spectroscopy Based on Single Beam Splitting and Geometric Configuration for Effective Signal Enhancement

    Science.gov (United States)

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-01

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS). In spatial configuration, the laser beam geometry plays an important role in the emission signal enhancement. Thus, an adjustable geometric configuration with variable incident angle between the two splitted laser beams was constructed for achieving maximum signal enhancement. With the optimized angles of 60° and 70° for Al and Cu atomic emission lines at 396.15 nm and 324.75 nm respectively, about 5.6- and 4.8-folds signal enhancements were achieved for aluminum alloy and copper alloy samples compared to SP-LIBS. Furthermore, the temporal analysis, in which the intensity of atomic lines in SP-LIBS decayed at least ten times faster than the SBS-LIBS, proved that the energy coupling efficiency of SBS-LIBS was significantly higher than that of SP-LIBS. PMID:25557721

  19. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  20. Investigations of high mobility single crystal chemical vapor deposition diamond for radiotherapy photon beam monitoring

    Science.gov (United States)

    Tromson, D.; Descamps, C.; Tranchant, N.; Bergonzo, P.; Nesladek, M.; Isambert, A.

    2008-03-01

    The intrinsic properties of diamond make this material theoretically very suitable for applications in medical physics. Until now ionization chambers have been fabricated from natural stones and are commercialized by PTW, but their fairly high costs and long delivery times have often limited their use in hospital. The properties of commercialized intrinsic polycrystalline diamond were investigated in the past by many groups. The results were not completely satisfactory due to the nature of the polycrystalline material itself. In contrast, the recent progresses in the growth of high mobility single crystal synthetic diamonds prepared by chemical vapor deposition (CVD) technique offer new alternatives. In the framework of the MAESTRO project (Methods and Advanced Treatments and Simulations for Radio Oncology), the CEA-LIST is studying the potentialities of synthetic diamond for new techniques of irradiation such as intensity modulated radiation therapy. In this paper, we present the growth and characteristics of single crystal diamond prepared at CEA-LIST in the framework of the NoRHDia project (Novel Radiation Hard CVD Diamond Detector for Hadrons Physics), as well as the investigations of high mobility single crystal CVD diamond for radiotherapy photon beam monitoring: dosimetric analysis performed with the single crystal diamond detector in terms of stability and repeatability of the response signal, signal to noise ratio, response speed, linearity of the signal versus the absorbed dose, and dose rate. The measurements performed with photon beams using radiotherapy facilities demonstrate that single crystal CVD diamond is a good alternative for air ionization chambers for beam quality control.

  1. Effects of underwater turbulence on laser beam propagation and coupling into single-mode optical fiber.

    Science.gov (United States)

    Hanson, Frank; Lasher, Mark

    2010-06-01

    We characterize and compare the effects of turbulence on underwater laser propagation with theory. Measurements of the coupling efficiency of the focused beam into a single-mode fiber are reported. A simple tip-tilt control system, based on the position of the image centroid in the focal plane, was shown to maintain good coupling efficiency for a beam radius equal to the transverse coherence length, r(0). These results are relevant to high bandwidth communication technology that requires good spatial mode quality.

  2. Fracture analysis of surface exfoliation on single crystal silicon irradiated by intense pulsed ion beam

    Science.gov (United States)

    Shen, Jie; Shahid, Ijaz; Yu, Xiao; Zhang, Jie; Zhong, Haowen; Cui, Xiaojun; Liang, Guoying; Yu, Xiang; Huang, Wanying; Yan, Sha; Zhang, Gaolong; Zhang, Xiaofu; Le, Xiaoyun

    2017-12-01

    Surface exfoliation was observed on single crystal silicon surface irradiated by Intense Pulsed Ion Beam (IPIB). As the strong transient thermal stress impact induced by IPIB was mainly attributed to the exfoliation, a micro scale model combined with thermal conduction and linear elastic fracture mechanics was built to analyze the thermal stress distribution along the energy deposition process. After computation with finite element method, J integral parameter was applied as the criterion for crack development. It was demonstrated that the exfoliation initiation calls for specific material, crack depth and IPIB parameter. The results are potentially valuable for beam/target selection and IPIB parameter optimization.

  3. Internal V-Band Clamp

    Science.gov (United States)

    Vaughn, Mark R.; Hafenrichter, Everett S.; Chapa, Agapito C.; Harris, Steven M.; Martinez, Marcus J.; Baty, Roy S.

    2006-02-28

    A system for clamping two tubular members together in an end-to-end relationship uses a split ring with a V-shaped outer rim that can engage a clamping surface on each member. The split ring has a relaxed closed state where the ends of the ring are adjacent and the outside diameter of the split ring is less than the minimum inside diameter of the members at their ends. The members are clamped when the split ring is spread into an elastically stretched position where the ring rim is pressed tightly against the interior surfaces of the members. Mechanisms are provided for removing the spreader so the split ring will return to the relaxed state, releasing the clamped members.

  4. Dynamic analysis of slender launching system connected by clamp band joint using harmonic balance method

    International Nuclear Information System (INIS)

    Qin, Z Y; Yan, S Z; Chu, F L

    2013-01-01

    Clamp band joints are widely used to fasten spacecrafts onto launching systems. Due to the unilateral constraints and the frictional slippage at the joint interface, clamp band joints may bring nonlinearity into launching systems during launching process. In this paper, the dynamics of a slender launching system with clamp band joint is investigated using harmonic balance method. Firstly, the formulas for the joint stiffness of the clamp band joint are proposed. Then, the finite element model for the launch vehicle and the spacecraft connected by the clamp band joint is developed, where the clamp band joint is represented by a massless beam element. Finally, harmonic balance method is applied to calculate the steady state response of the launching system

  5. Planar patch-clamp force microscopy on living cells

    Energy Technology Data Exchange (ETDEWEB)

    Pamir, Evren [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany); George, Michael; Fertig, Niels [Nanion Technologies GmbH, Erzgiessereistr. 4, 80335 Munich (Germany); Benoit, Martin [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany)], E-mail: martin.benoit@physik.uni-muenchen.de

    2008-05-15

    Here we report a new combination of the patch-clamp technique with the atomic force microscope (AFM). A planar patch-clamp chip microstructured from borosilicate glass was used as a support for mechanical probing of living cells. The setup not only allows for immobilizing even a non-adherent cell for measurements of its mechanical properties, but also for simultaneously measuring the electrophysiological properties of a single cell. As a proof of principle experiment we measured the voltage-induced membrane movement of HEK293 and Jurkat cells in the whole-cell voltage clamp configuration. The results of these measurements are in good agreement with previous studies. By using the planar patch-clamp chip for immobilization, the AFM not only can image non-adhering cells, but also gets easily access to an electrophysiologically controlled cellular probe at low vibrational noise.

  6. The tensile effect on crack formation in single crystal silicon irradiated by intense pulsed ion beam

    Science.gov (United States)

    Liang, Guoying; Shen, Jie; Zhang, Jie; Zhong, Haowen; Cui, Xiaojun; Yan, Sha; Zhang, Xiaofu; Yu, Xiao; Le, Xiaoyun

    2017-10-01

    Improving antifatigue performance of silicon substrate is very important for the development of semiconductor industry. The cracking behavior of silicon under intense pulsed ion beam irradiation was studied by numerical simulation in order to understand the mechanism of induced surface peeling observed by experimental means. Using molecular dynamics simulation based on Stillinger Weber potential, tensile effect on crack growth and propagation in single crystal silicon was investigated. Simulation results reveal that stress-strain curves of single crystal silicon at a constant strain rate can be divided into three stages, which are not similar to metal stress-strain curves; different tensile load velocities induce difference of single silicon crack formation speed; the layered stress results in crack formation in single crystal silicon. It is concluded that the crack growth and propagation is more sensitive to strain rate, tensile load velocity, stress distribution in single crystal silicon.

  7. A feasibility study of in vivo applications of single beam acoustic tweezers

    Science.gov (United States)

    Li, Ying; Lee, Changyang; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk

    2014-10-01

    Tools that are capable of manipulating micro-sized objects have been widely used in such fields as physics, chemistry, biology, and medicine. Several devices, including optical tweezers, atomic force microscope, micro-pipette aspirator, and standing surface wave type acoustic tweezers have been studied to satisfy this need. However, none of them has been demonstrated to be suitable for in vivo and clinical studies. Single beam acoustic tweezers (SBAT) is a technology that uses highly focused acoustic beam to trap particles toward the beam focus. Its feasibility was first theoretically and experimentally demonstrated by Lee and Shung several years ago. Since then, much effort has been devoted to improving this technology. At present, the tool is capable of trapping a microparticle as small as 1 μm, as well as a single red blood cell. Although in comparing to other microparticles manipulating technologies, SBAT has advantages of providing stronger trapping force and deeper penetration depth in tissues, and producing less tissue damage, its potential for in vivo applications has yet been explored. It is worth noting that ultrasound has been used as a diagnostic tool for over 50 years and no known major adverse effects have been observed at the diagnostic energy level. This paper reports the results of an initial attempt to assess the feasibility of single beam acoustic tweezers to trap microparticles in vivo inside of a blood vessel. The acoustic intensity of SBAT under the trapping conditions that were utilized was measured. The mechanical index and thermal index at the focus of acoustic beam were found to be 0.48 and 0.044, respectively, which meet the standard of commercial diagnostic ultrasound system.

  8. SRAM single event upset calculation and test using protons in the secondary beam in the BEPC

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yuanming; Guo Hongxia; Zhang Fengqi; Zhang Keying; Chen Wei; Luo Yinhong; Guo Xiaoqiang, E-mail: wangym2007@gmail.com [Northwest Institute of Nuclear Technology, Xi' an 710024 (China)

    2011-09-15

    The protons in the secondary beam in the Beijing Electron Positron Collider (BEPC) are first analyzed and a large proportion at the energy of 50-100 MeV supply a source gap of high energy protons. In this study, the proton energy spectrum of the secondary beam was obtained and a model for calculating the proton single event upset (SEU) cross section of a static random access memory (SRAM) cell has been presented in the BEPC secondary beam proton radiation environment. The proton SEU cross section for different characteristic dimensions has been calculated. The test of SRAM SEU cross sections has been designed, and a good linear relation between SEUs in SRAM and the fluence was found, which is evidence that an SEU has taken place in the SRAM. The SEU cross sections were measured in SRAM with different dimensions. The test result shows that the SEU cross section per bit will decrease with the decrease of the characteristic dimensions of the device, while the total SEU cross section still increases upon the increase of device capacity. The test data accords with the calculation results, so the high-energy proton SEU test on the proton beam in the BEPC secondary beam could be conducted. (semiconductor physics)

  9. Single-beam measurements of LHC instability threshold in terms of octupole current

    CERN Document Server

    Mounet, N; Buffat, X; Burov, A; Hemelsoet, G; Metral, E; Papotti, G; Pieloni, T; Pojer, M; Salvant, B; Trad, G

    2012-01-01

    This note summarizes two machine development (MD) studies aimed at determining the octupole current needed in the LHC in order to stabilize all headtail instabilities at 4TeV/c, before and after the squeeze, with tight collimator settings, and when a single beam (beam 2) at maximum intensity (1380 bunches, 2.1 1014 protons) is present in the machine. The MDs followed the normal physics operation procedure, at the notable exception that a single beam was used, the other beam containing only one non-colliding nominal bunch. Octupole current (with negative polarity in the focusing octupoles and the opposite in the defocusing ones) was decreased by small steps until the instability threshold was reached. This was performed in two distinct MDs, one before the squeeze and the other after it, testing also several chromaticity values and the effect of the transverse damper in the latter case. Octupole thresholds are shown in each case studied, as well as the rise times of the instabilities observed.

  10. The effects of two counterpropagating surface acoustic wave beams on single electron acoustic charge transport

    International Nuclear Information System (INIS)

    He Jianhong; Guo Huazhong; Song Li; Zhang Wei; Gao Jie; Lu Chuan

    2010-01-01

    We present a comprehensive study of the effects of two counterpropagating surface acoustic waves on the acoustoelectric current of single electron transport devices. A significant improvement in the accuracy of current quantization is achieved as a result of an additional surface acoustic wave beam. The experiments reveal the sinusoidally periodical modulation in the acoustoelectric current characteristic as a function of the relative phase of the two surface acoustic wave beams. Besides, by using standing surface acoustic waves, the acoustoelectric current is detected which we consider as the so-called anomalous acoustoelectric current produced by acoustic wave mechanical deformations. This kind current is contributed to one component of the acoustoelectric current in surface acoustic wave device, which could enable us to establish a more adequate description of acoustoelectric effects on single-electron acoustic charge transport.

  11. Optical trap for both transparent and absorbing particles in air using a single shaped laser beam.

    Science.gov (United States)

    Redding, Brandon; Pan, Yong-Le

    2015-06-15

    Optical trapping of airborne particles is emerging as an essential tool in applications ranging from online characterization of living cells and aerosols to particle transport and delivery. However, existing optical trapping techniques using a single laser beam can trap only transparent particles (via the radiative pressure force) or absorbing particles (via the photophoretic force), but not particles of either type-limiting the utility of trapping-enabled aerosol characterization techniques. Here, we present the first optical trapping technique capable of trapping both transparent and absorbing particles with arbitrary morphology using a single shaped laser beam. Such a general-purpose optical trapping mechanism could enable new applications such as trapping-enabled aerosol characterization with high specificity.

  12. Characterization of strained InGaAs single quantum well structures by ion beam methods

    International Nuclear Information System (INIS)

    Yu, K.M.; Chan, K.T.

    1990-01-01

    We have investigated strained InGaAs single quantum well structures using MeV ion beam methods. The structural properties of these structures, including composition and well size, have been studied. It has been found that the composition obtained by Rutherford backscattering spectrometry and particle-induced x-ray emission techniques agrees very well with that obtained by the ion channeling method

  13. Model for a collimated spin wave beam generated by a single layer, spin torque nanocontact

    OpenAIRE

    Hoefer, M. A.; Silva, T. J.; Stiles, M. D.

    2007-01-01

    A model of spin torque induced magnetization dynamics based upon semi-classical spin diffusion theory for a single layer nanocontact is presented. The model incorporates effects due to the current induced Oersted field and predicts the generation of a variety of spatially dependent, coherent, precessional magnetic wave structures. Directionally controllable collimated spin wave beams, vortex spiral waves, and localized standing waves are found to be excited by the interplay of the Oersted fie...

  14. Direct fabrication of diffraction grating onto organic single crystals by electron beam lithography

    Science.gov (United States)

    Kawata, Yoshihiro; Aoki, Kazuki; Inada, Yuhi; Yamao, Takeshi; Hotta, Shu

    2018-03-01

    We have directly fabricated a diffraction grating onto platelike single crystals made of an organic semiconducting oligomer by electron beam lithography followed by reactive-ion etching. The decrease in the grating period resulted in photoexcited spectrally narrowed emission peaks related to the first-order diffraction from the crystal edge without outstanding quenching of the crystal. This work is expected to lead to the realization of organic semiconductor lasers.

  15. An Analytical Model for Predicting the Stress Distributions within Single-Lap Adhesively Bonded Beams

    Directory of Open Access Journals (Sweden)

    Xiaocong He

    2014-01-01

    Full Text Available An analytical model for predicting the stress distributions within single-lap adhesively bonded beams under tension is presented in this paper. By combining the governing equations of each adherend with the joint kinematics, the overall system of governing equations can be obtained. Both the adherends and the adhesive are assumed to be under plane strain condition. With suitable boundary conditions, the stress distribution of the adhesive in the longitudinal direction is determined.

  16. Improved single particle potential for transport model simulations of nuclear reactions induced by rare isotope beams

    International Nuclear Information System (INIS)

    Xu Chang; Li Baoan

    2010-01-01

    Taking into account more accurately the isospin dependence of nucleon-nucleon interactions in the in-medium many-body force term of the Gogny effective interaction, new expressions for the single-nucleon potential and the symmetry energy are derived. Effects of both the spin (isospin) and the density dependence of nuclear effective interactions on the symmetry potential and the symmetry energy are examined. It is shown that they both play a crucial role in determining the symmetry potential and the symmetry energy at suprasaturation densities. The improved single-nucleon potential will be useful for more accurate simulation of nuclear reactions induced by rare-isotope beams within transport models.

  17. Anisotropy effect of crater formation on single crystal silicon surface under intense pulsed ion beam irradiation

    Science.gov (United States)

    Shen, Jie; Yu, Xiao; Zhang, Jie; Zhong, Haowen; Cui, Xiaojun; Liang, Guoying; Yu, Xiang; Huang, Wanying; Shahid, Ijaz; Zhang, Xiaofu; Yan, Sha; Le, Xiaoyun

    2018-04-01

    Due to the induced extremely fast thermal and dynamic process, Intense Pulsed Ion Beam (IPIB) is widely applied in material processing, which can bring enhanced material performance and surface craters as well. To investigate the craters' formation mechanism, a specific model was built with Finite Element Methods (FEM) to simulate the thermal field on irradiated single crystal silicon. The direct evidence for the existence of the simulated 6-fold rotational symmetric thermal distribution was provided by electron microscope images obtained on single crystal silicon. The correlation of the experiment and simulation is of great importance to understand the interaction between IPIB and materials.

  18. Single Chip Lidar with Discrete Beam Steering by Digital Micromirror Device

    Science.gov (United States)

    Smith, Braden

    A novel method of beam steering that utilizes a mass-produced Digital Micromirror Device (DMD) enables a large field of view and reliable single chip Light Detection and Ranging (LIDAR). Using a short pulsed laser, the micromirrors' rotation is frozen mid-transition which forms a programmable blazed grating which efficiently redistributes the light to a single diffraction order, among several. With a nanosecond 905nm laser and Si avalanche photo diode, measurement accuracy of range and with a 48° full field of view.

  19. Single and multi degree of freedom analysis of steel beams under blast loading

    International Nuclear Information System (INIS)

    Nassr, Amr A.; Razaqpur, A. Ghani; Tait, Michael J.; Campidelli, Manuel; Foo, Simon

    2012-01-01

    Highlights: ► Experimentally tested beams under blast are analyzed using SDOF and MDOF models. ► SDOF model adequately captures the time dependant deformations and internal forces. ► Constant DIF based on a low strain rate leads to conservative estimate of the DIF. ► The responses of the test beams are governed by the first mode of vibration. - Abstract: This paper presents detailed analysis of the results of field tests on 13 full scale wide flange steel beams subjected to blast loads generated by the detonation of up to 250 kg of ANFO explosive. The experimental results are analyzed using an equivalent Single-Degree-of-Freedom (SDOF) model of a beam, which includes material nonlinearity and strain rate effects. To account for strain rate effect on beam stiffness and strength, its full moment-curvature response is determined by dividing its cross-section into a number of layers and a strain rate-dependent stress-strain relationship, based on the Cowper–Symonds strain rate model, is used to capture the nonlinear stress distribution over the section. To determine the effects of higher modes of vibration and the variation of beam mechanical properties along its length on its dynamic response, the test beams are also analyzed using a Multi-Degree-of-Freedom (MDOF) model involving beam finite elements. Each element has two nodes and three degrees of freedom and is again divided into a number of layers to capture the strain rate effect and nonlinear stress distribution over its depth. The predicted displacements and strains by the two models are compared with the corresponding experimental data and the results show that for the given beams, the time-dependant deformations, internal forces, and moments can be adequately predicted by either model because the first mode of vibration is found to dominate their response; however, the use of a constant strain rate through the so-called Dynamic Increase Factor (DIF) can lead to highly conservative estimate of the

  20. How to Assess the Quality of Glucose Clamps? Evaluation of Clamps Performed With ClampArt, a Novel Automated Clamp Device.

    Science.gov (United States)

    Benesch, Carsten; Heise, Tim; Klein, Oliver; Heinemann, Lutz; Arnolds, Sabine

    2015-07-01

    There are no widely accepted parameters to assess the quality of glucose clamps. Thus, we selected different parameters describing clamp quality. These parameters were then evaluated in glucose clamps carried out with ClampArt, a novel CE-marked, state-of-the-art fully automated glucose clamp device employing continuous blood glucose (BG) measurements and minute-by-minute adaptations of glucose infusion rate (GIR). Thirty-nine glucose clamps were performed in 10 healthy and 29 subjects with type 1 diabetes (T1DM) (total duration 583 h). ClampArt-based BG measurements were compared with those obtained with a laboratory reference method. Clamp quality was assessed by 5 parameters: (1) difference (mg/dl) of all paired BG measurements of ClampArt versus reference method ("trueness"), (2) coefficient of variation (CV, %) of ClampArt's BG measurements at target clamp level ("precision"), (3) mean absolute relative difference (MARD, %) at target clamp level ("accuracy"), (4) difference (mg/dl) between ClampArt and target BG ("control deviation"), and (5) percentage operational time ("utility"). ClampArt-based BG measurements showed a trueness of 1.2 ± 2.5 mg/dl. CV and MARD at target BG were 5.5 ± 2.1% and 5.3 ± 2.3%, respectively. There were only small deviations from target level (1.2 ± 1.6 mg/dl). Operational time was as high as 95.4% ± 4.1% (means ± SD). The selected parameters seem to be adequate to characterize clamp quality. The novel, fully automated clamp device ClampArt achieves high clamp quality, which in future trials should be compared with other (automated and manual) clamp methods. © 2015 Diabetes Technology Society.

  1. Micromachined patch-clamp apparatus

    Science.gov (United States)

    Okandan, Murat

    2012-12-04

    A micromachined patch-clamp apparatus is disclosed for holding one or more cells and providing electrical, chemical, or mechanical stimulation to the cells during analysis with the patch-clamp technique for studying ion channels in cell membranes. The apparatus formed on a silicon substrate utilizes a lower chamber formed from silicon nitride using surface micromachining and an upper chamber formed from a molded polymer material. An opening in a common wall between the chambers is used to trap and hold a cell for analysis using the patch-clamp technique with sensing electrodes on each side of the cell. Some embodiments of the present invention utilize one or more electrostatic actuators formed on the substrate to provide mechanical stimulation to the cell being analyzed, or to provide information about mechanical movement of the cell in response to electrical or chemical stimulation.

  2. Production of multi-, oligo- and single-pore membranes using a continuous ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Apel, P.Yu., E-mail: apel@nrmail.jinr.ru [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation); Dubna International University, Universitetskaya Str. 19, 141980 Dubna (Russian Federation); Ivanov, O.M.; Lizunov, N.E.; Mamonova, T.I.; Nechaev, A.N. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation); Olejniczak, K. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation); Faculty of Chemistry, Nicolaus Copernicus University, Gagarina Str. 7, 87-100 Torun (Poland); Vacik, J. [Nuclear Physics Institute, ASCR, v.v.i., 25068 Řež (Czech Republic); Dmitriev, S.N. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation)

    2015-12-15

    Ion track membranes (ITM) have attracted significant interest over the past two decades due to their numerous applications in physical, biological, chemical, biochemical and medical experimental works. A particular feature of ITM technology is the possibility to fabricate samples with a predetermined number of pores, including single-pore membranes. The present report describes a procedure that allowed for the production of multi-, oligo- and single-pore membranes using a continuous ion beam from an IC-100 cyclotron. The beam was scanned over a set of small diaphragms, from 17 to ∼1000 μm in diameter. Ions passed through the apertures and impinged two sandwiched polymer foils, with the total thickness close to the ion range in the polymer. The foils were pulled across the ion beam at a constant speed. The ratio between the transport speed and the scanning frequency determined the distance between irradiation spots. The beam intensity and the aperture diameters were adjusted such that either several, one or no ions passed through the diaphragms during one half-period of scanning. After irradiation, the lower foil was separated from the upper foil and was etched to obtain pores 6–8 μm in diameter. The pores were found using a color chemical reaction between two reagents placed on opposite sides of the foil. The located pores were further confirmed using SEM and optical microscopy. The numbers of tracks in the irradiation spots were consistent with the Poisson statistics. Samples with single or few tracks obtained in this way were employed to study fine phenomena in ion track nanopores.

  3. Single-shot beam profile diagnostics for x-ray FEL's using gas fluorescence

    Science.gov (United States)

    Feng, Yiping; Zhu, Diling; Weninger, Clemens; Alonso-Mori, Roberto; Chollet, Matthieu; Damiani, Daniel S.; Glownia, James M.; Hastings, Jerome B.; Nelson, Silke; Song, Sanghoon; Robert, Aymeric

    2017-06-01

    We report experimental demonstration of capturing single-shot X-ray Free-electron Laser (FEL) beam profiles using gas fluorescence. The measurement was carried out at the Linac Coherent Light Source using 7 keV hard X-rays propagating through ambient air. The nitrogen fluorescence emitted upon the passage of the X-ray FEL beam were imaged using a highly sensitive optical setup, and there was sufficient optical yield that single-shot measurements were feasible. By taking two orthogonal and simultaneous images, the beam trajectory could be determined in a nearly non-invasive manner, and is best suited for photon energies in the soft X-ray regime, where such a diagnostic capability has been largely unavailable previously. The integrated intensity of the images could also serve as a non-invasive intensity monitor, complementary to current implementations of gas- and solidbased monitors. High repetition-rate Free-electron Lasers can greatly benefit from such a new diagnostic tool for eliminating potential thermal damages.

  4. Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording.

    Science.gov (United States)

    Harrison, Reid R; Kolb, Ilya; Kodandaramaiah, Suhasa B; Chubykin, Alexander A; Yang, Aimei; Bear, Mark F; Boyden, Edward S; Forest, Craig R

    2015-02-15

    Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput of patch clamping for single-ion channel and single-cell analyses. In this work, we have developed a custom patch-clamp amplifier microchip that can be fabricated using standard commercial silicon processes capable of performing both voltage- and current-clamp measurements. A key innovation is the use of nonlinear feedback elements in the voltage-clamp amplifier circuit to convert measured currents into logarithmically encoded voltages, thereby eliminating the need for large high-valued resistors, a factor that has limited previous attempts at integration. Benchtop characterization of the chip shows low levels of current noise [1.1 pA root mean square (rms) over 5 kHz] during voltage-clamp measurements and low levels of voltage noise (8.2 μV rms over 10 kHz) during current-clamp measurements. We demonstrate the ability of the chip to perform both current- and voltage-clamp measurement in vitro in HEK293FT cells and cultured neurons. We also demonstrate its ability to perform in vivo recordings as part of a robotic patch-clamping system. The performance of the patch-clamp amplifier microchip compares favorably with much larger commercial instrumentation, enabling benchtop commoditization, miniaturization, and scalable patch-clamp instrumentation. Copyright © 2015 the American Physiological Society.

  5. Development of a Charged Particle Microbeam for Single-Particle Subcellular Irradiations at the MIT Laboratory for Accelerator Beam Application

    International Nuclear Information System (INIS)

    Yanch, Jacquelyn C.

    2004-01-01

    The development of a charged particle microbeam for single particle, subcellular irradiations at the Massachusetts Institute of Technology Laboratory for Accelerator Beam Applications (MIT LABA) was initiated under this NEER aeard. The Microbeam apparatus makes use of a pre-existing electrostatic accelerator with a horizontal beam tube

  6. A simulation study on the dose distribution for a single beam of the gamma knife

    International Nuclear Information System (INIS)

    Chen, Chin-cheng; Jiang, Shiang-Huei; Lee, Chung-chi; Shiau, Cheng-Ying

    2000-01-01

    The purpose of this study is to evaluate the impact of the tissue heterogeneity on the dose distribution for a single beam of the gamma knife. The EGS4 Monte Carlo code was used to simulate both depth and radial profiles of the radiation dose in homogeneous and heterogeneous phantoms, respectively. The results are compared with the dose distribution calculated using the mathematical model of Gamma Plan, the treatment planning system of the gamma knife. The skull and sinus heterogeneity were simulated by a Teflon shell and an air shell, respectively. It was found that the tissue heterogeneity caused significant perturbation on the absolute depth dose at the focus as well as on the depth-dose distribution near the phantom surface and/or at the interface but little effect on the radial dose distribution. The effect of the beam aperture on the depth-dose distribution was also investigated in this study. (author)

  7. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    CMS Collaboration

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hard sensors. Inside CMS two rings instrumented with 12 single crystal diamond sensors each are installed on both sides of the interaction point. The sensors are subdivided in two pads, and each pad is read out by a dedicated fast radiation hard ASIC in 130 nm CMOS technology. Due to the excellent time resolution collision products will be separated from machine induced background. In the backend a dead-time less histogramming unit is used, and a fast microTCA system with GHz sampling rate is under development. The detector will measure both the on-line luminosity and the background bunch-by-bunch. The performance of a prototype detector in a test-beam will be reported, and results from the operation during data taking will be presented.

  8. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    Karacheban, Olena

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hardsensors. Inside CMS two rings instrumented with 12 single crystal diamondsensors each are installed on both sides of the interaction point. Thesensors are subdivided in two pads, and each pad is read out by adedicated fast radiation hard ASIC in 130 nm CMOS technology.Due to the excellent time resolution collision products will be separatedfrom machine induced background. In the backend a dead-time lesshistogramming unit is udsed, and a fast microTCA system with GHz samplingrate is under development.The detector will measure both the on-line luminosity and the backgroundbunch-by-bunch.The performance of a prototype detector in a test-beam will be reported,and results from the operation during data taking will be presented.

  9. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  10. Intensity-gradient induced Sisyphus cooling of a single atom in a localized hollow-beam trap

    International Nuclear Information System (INIS)

    Yin, Yaling; Xia, Yong; Ren, Ruimin; Du, Xiangli; Yin, Jianping

    2015-01-01

    In order to realize a convenient and efficient laser cooling of a single atom, we propose a simple and promising scheme to cool a single neutral atom in a blue-detuned localized hollow-beam trap by intensity-gradient induced Sisyphus cooling, and study the dynamic process of the intensity-gradient cooling of a single 87 Rb atom in the localized hollow-beam trap by using Monte-Carlo simulations. Our study shows that a single 87 Rb atom with a temperature of 120 μK from a magneto-optical trap (MOT) can be directly cooled to a final temperature of 4.64 μK in our proposed scheme. We also investigate the dependences of the cooling results on the laser detuning δ of the localized hollow-beam, the power RP 0 of the re-pumping laser beam, the sizes of both the localized hollow-beam and the re-pumping beam, and find that there is a pair of optimal cooling parameters (δ and RP 0 ) for an expected lowest temperature, and the cooling results strongly depend on the size of the re-pumping beam, but weakly depend on the size of the localized hollow-beam. Finally, we further study the cooling potential of our localized hollow-beam trap for the initial temperature of a single atom, and find that a single 87 Rb atom with an initial temperature of higher than 1 mK can also be cooled directly to about 6.6 μK. (paper)

  11. Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument

    International Nuclear Information System (INIS)

    Lekstrom, M; McLachlan, M A; Husain, S; McComb, D W; Shollock, B A

    2008-01-01

    Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, which can be attached to a cut-out FIB section using ion beam induced platinum deposition. This article addresses the issues of using an ion beam to monitor the in situ manipulation process as well as approaches that can be used to create stronger platinum welds between two objects, and finally, views on how to limit the extent of ion beam damage to the specimen surface.

  12. Spectrum sensing using single-radio switched-beam antenna systems

    DEFF Research Database (Denmark)

    Tsakalaki, Elpiniki; Wilcox, David; De Carvalho, Elisabeth

    2012-01-01

    The paper describes spectrum sensing using single-radio switched-beam arrays with reactance-loaded parasitic elements. At a given frequency, the antenna's loading conditions (reactive loads) are optimized for maximum average beamforming gain in the beampattern look direction. Circular permutations...... of the reactive loads rotate the narrowband beampattern to different angular positions dividing the whole space around the cognitive receiver into several angular subspaces. The beampattern directionality leverages the performance of spectrum sensing algorithms like the energy detection by enhancing the receive...

  13. Machining with micro-size single crystalline diamond tools fabricated by a focused ion beam

    International Nuclear Information System (INIS)

    Ding, X; Butler, D L; Lim, G C; Shaw, K C; Liu, K; Fong, W S; Zheng, H Y; Cheng, C K

    2009-01-01

    A study was carried out to understand the physics of micro-scale mechanical machining (henceforth referred to as 'micro-machining') with a micro-size tool using a five-axis ultra-precision machine. A micro-size single crystalline diamond (SCD) tool with sharp cutting edges fabricated by a focused ion beam (FIB) was employed to orthogonal-machine four materials (three polycrystalline metals with various grain sizes and one amorphous metal plating material). Since the wealth of knowledge of macro-machining cannot be successfully used in micro-machining, this study contributes to the understanding of the physics of mechanical machining with micro-size tools

  14. The actuation characterization of cantilevered unimorph beams with single crystal piezoelectric materials

    International Nuclear Information System (INIS)

    Bilgen, Onur; Friswell, Michael I; Amin Karami, M; Inman, Daniel J

    2011-01-01

    An experimental and theoretical electromechanical characterization of beam-like, uniform cross-section, unimorph structures employing single crystal piezoelectrics is presented. The purpose of the research is to understand and compare the actuation capabilities of several piezoelectric materials and substrate configurations so that optimal design choices can be employed in lightweight, low power aerodynamic applications. Monolithic devices made from three kinds of piezoelectrics—single crystal PMN–PZT (lead magnesium niobate–lead zirconate titanate) and the polycrystalline PZT-5A and PZT-5H types—are compared in a unimorph cantilevered beam configuration. A total of 24 unimorph specimens are fabricated and the validity of existing models is examined through experimentation. The tip velocity response to harmonic voltage excitation is measured and compared to the analytical prediction with the perfect bonding assumption. Summarizing, it was confirmed that the substrate-to-piezoelectric thickness ratio and substrate modulus are the important design parameters in determining the measured output of the unimorphs and the accuracy of the model prediction. The single crystal piezoelectrics demonstrated actuation authority two to four times higher (measured in terms of peak displacement per applied voltage) when compared to the polycrystalline piezoceramics for the same substrate material and geometry choice. In contrast to the higher actuation output, practical implementation issues are noted for the single crystal devices. The lack of grain boundaries (as in the polycrystalline material) makes the single crystals very 'brittle' and susceptible to stress concentrations. Another important limitation is the low transition temperature, which limits the use of conventional solder materials in creating electrical connections

  15. Hot clamp design for LMFBR piping systems

    International Nuclear Information System (INIS)

    Kobayashi, T.; Tateishi, M.

    1990-01-01

    Thin wall large diameter piping for liquid metal fast breeder reactor plants can be subjected to significant thermal transients during reactor scrams. To reduce local thermal stresses, an insulted cold clamp was designed for the Fast Flux Test Facility and was also applied to some following prototype reactors. However, the cost minimization of LMFBR requires much simpler designs. This paper presents a hot clamp design concept, which uses standard clamp halves directly attached to the pipe surface with an initial gap. Combinations of flexible pipe and rigid clamp achieved a self-control effect on clamp induced pipe stresses due to the initial gap. A 3-D contact and inelastic history analysis were performed to verify the hot clamp concept. Considerations to reduce the initial stress at installation, to mitigate the clamp restraint on the pipe expansion during thermal shocks, and to maintain the pipe-clamp stiffness desired during a seismic event are discussed

  16. Hot clamp design for LMFBR piping systems

    International Nuclear Information System (INIS)

    Kobayashi, T.; Tateishi, M.

    1993-01-01

    Thin-wall, large-diameter piping for liquid metal fast breeder reactor (LMFBR) plants can be subjected to significant thermal transients during reactor scrams. To reduce local thermal stresses, an insulated cold clamp was designed for the fast flux test facility and was also applied to some prototype reactors thereafter. However, the cost minimization of LMFBR requires much simpler designs. This paper presents a hot clamp design concept, which uses standard clamp halves directly attached to the pipe surface leaving an initial gap. Combinations of flexible pipe and rigid clamp achieved a self-control effect on clamp-induced pipe stresses due to the initial gap. A 3-D contact and inelastic history analysis were performed to verify the hot clamp concept. Considerations to reduce the initial stress at installation, to mitigate the clamp restraint on the pipe expansion during thermal shocks, and to maintain the pipe-clamp stiffness desired during a seismic event were discussed

  17. Multifrequency Excitation of a Clamped-Clamped Microbeam

    KAUST Repository

    Jaber, Nizar R.

    2016-01-20

    We present analytical and experimental investigation of an electrically actuated clamped-clamped microbeam under a twosource harmonic excitation. The first frequency is swept around the first mode of vibration where the second one is fixed. These microbeams are fabricated using polyimide as structural layer coated with nickel form top and chromium and gold layers from bottom. We demonstrate the excitation of additive and subtractive type resonance. We show that by properly tuning the frequency and the amplitude of the excitation force, the frequency bandwidth of the resonator is increased. Theoretically, we solved the eigenvalue problem for different axial forces to find the natural frequencies ratio that match the experimental values. Using Galerkin method, a reduced order model is derived to simulate the static and dynamic response of the device where using three symmetric mode shapes provided a good agreement with experimental data. © Copyright 2015 by ASME.

  18. Coherent multi-dimensional spectroscopy at optical frequencies in a single beam with optical readout

    Science.gov (United States)

    Seiler, Hélène; Palato, Samuel; Kambhampati, Patanjali

    2017-09-01

    Ultrafast coherent multi-dimensional spectroscopies form a powerful set of techniques to unravel complex processes, ranging from light-harvesting, chemical exchange in biological systems to many-body interactions in quantum-confined materials. Yet these spectroscopies remain complex to implement at the high frequencies of vibrational and electronic transitions, thereby limiting their widespread use. Here we demonstrate the feasibility of two-dimensional spectroscopy at optical frequencies in a single beam. Femtosecond optical pulses are spectrally broadened to a relevant bandwidth and subsequently shaped into phase coherent pulse trains. By suitably modulating the phases of the pulses within the beam, we show that it is possible to directly read out the relevant optical signals. This work shows that one needs neither complex beam geometries nor complex detection schemes in order to measure two-dimensional spectra at optical frequencies. Our setup provides not only a simplified experimental design over standard two-dimensional spectrometers but its optical readout also enables novel applications in microscopy.

  19. Console-integrated real-time three-dimensional image overlay navigation for robot-assisted partial nephrectomy with selective arterial clamping: early single-centre experience with 17 cases.

    Science.gov (United States)

    Furukawa, Junya; Miyake, Hideaki; Tanaka, Kazushi; Sugimoto, Maki; Fujisawa, Masato

    2014-12-01

    The objective of this study was to describe our early experience with robot-assisted partial nephrectomy (RAPN) incorporating selective arterial clamping, using an image overlay navigation system. Three-dimensional images were reconstructed from computed tomography using open source processing software, OsiriX, and were directly visualized on the screen of a da Vinci surgeon's console with TilePro multi-input display functions. Using this imaging system, RAPN with selective arterial clamping was performed in 17 patients with renal tumours. The intraoperative image overlay navigation system made it possible to clearly show the tumour position and vascular supply within the console's field of view, and facilitate selective arterial clamping during RAPN, resulting in a mean decrease in estimated glomerular filtration rates at both 1 and 4 weeks after RAPN < 10 ml/min/1.73 m(2) . RAPN with selective arterial clamping using this innovative imaging system could be a useful alternative to conventional RAPN. Copyright © 2014 John Wiley & Sons, Ltd.

  20. 21 CFR 870.4450 - Vascular clamp.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clamp. 870.4450 Section 870.4450 Food and... CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4450 Vascular clamp. (a) Identification. A vascular clamp is a surgical instrument used to occlude a blood vessel temporarily. (b) Classification. Class II...

  1. A visualization method for probing grain boundaries of single layer graphene via molecular beam epitaxy

    Science.gov (United States)

    Zhan, Linjie; Wan, Wen; Zhu, Zhenwei; Zhao, Zhijuan; Zhang, Zhenhan; Shih, Tien-Mo; Cai, Weiwei

    2017-07-01

    Graphene, a member of layered two-dimensional (2D) materials, possesses high carrier mobility, mechanical flexibility, and optical transparency, as well as enjoying a wide range of promising applications in electronics. Adopting the chemical vaporization deposition method, the majority of investigators have ubiquitously grown single layer graphene (SLG), which inevitably involves polycrystalline properties. Here we demonstrate a simple method for the direct visualization of arbitrarily large-size SLG domains by synthesizing one-hundred-nm-scale MoS2 single crystals via a high-vacuum molecular beam epitaxy process. The present study based on epitaxial growth provides a guide for probing the grain boundaries of various 2D materials and implements higher potentials for the next-generation electronic devices.

  2. Molecular beam epitaxy of single crystalline GaN nanowires on a flexible Ti foil

    Science.gov (United States)

    Calabrese, Gabriele; Corfdir, Pierre; Gao, Guanhui; Pfüller, Carsten; Trampert, Achim; Brandt, Oliver; Geelhaar, Lutz; Fernández-Garrido, Sergio

    2016-05-01

    We demonstrate the self-assembled growth of vertically aligned GaN nanowire ensembles on a flexible Ti foil by plasma-assisted molecular beam epitaxy. The analysis of single nanowires by transmission electron microscopy reveals that they are single crystalline. Low-temperature photoluminescence spectroscopy demonstrates that in comparison to standard GaN nanowires grown on Si, the nanowires prepared on the Ti foil exhibit an equivalent crystalline perfection, a higher density of basal-plane stacking faults, but a reduced density of inversion domain boundaries. The room-temperature photoluminescence spectrum of the nanowire ensemble is not influenced or degraded by the bending of the substrate. The present results pave the way for the fabrication of flexible optoelectronic devices based on GaN nanowires on metal foils.

  3. Molecular beam epitaxy of single crystalline GaN nanowires on a flexible Ti foil

    International Nuclear Information System (INIS)

    Calabrese, Gabriele; Corfdir, Pierre; Gao, Guanhui; Pfüller, Carsten; Trampert, Achim; Brandt, Oliver; Geelhaar, Lutz; Fernández-Garrido, Sergio

    2016-01-01

    We demonstrate the self-assembled growth of vertically aligned GaN nanowire ensembles on a flexible Ti foil by plasma-assisted molecular beam epitaxy. The analysis of single nanowires by transmission electron microscopy reveals that they are single crystalline. Low-temperature photoluminescence spectroscopy demonstrates that in comparison to standard GaN nanowires grown on Si, the nanowires prepared on the Ti foil exhibit an equivalent crystalline perfection, a higher density of basal-plane stacking faults, but a reduced density of inversion domain boundaries. The room-temperature photoluminescence spectrum of the nanowire ensemble is not influenced or degraded by the bending of the substrate. The present results pave the way for the fabrication of flexible optoelectronic devices based on GaN nanowires on metal foils.

  4. Single-bunch beam loading on the SLAC two-mile accelerator

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1976-05-01

    The experiments described were initially prompted by interest in the radiation loss of relativistic electron rings passing through periodic structures. Later the same experiments became relevant to the theory of energy loss of electrons in large storage rings. In both of these cases energy loss to the higher order modes of the respective structures could seriously limit their effective operation. In these experiments, single bunches of electrons with intensities up to 7 x 10 8 electrons per bunch are accelerated through the SLAC three-kilometer accelerator, and their energy spectra are analyzed. Early experiments over a wide energy range (900 MeV to 19 GeV) demonstrated that the energy loss was proportional to the total charge in the bunch but was independent of beam energy. The average energy loss of a single bunch normalized to 10 9 electrons was initially measured to be 38 MeV

  5. Upgrade of a Scanning Confocal Microscope to a Single-Beam Path STED Microscope.

    Directory of Open Access Journals (Sweden)

    André Klauss

    Full Text Available By overcoming the diffraction limit in light microscopy, super-resolution techniques, such as stimulated emission depletion (STED microscopy, are experiencing an increasing impact on life sciences. High costs and technically demanding setups, however, may still hinder a wider distribution of this innovation in biomedical research laboratories. As far-field microscopy is the most widely employed microscopy modality in the life sciences, upgrading already existing systems seems to be an attractive option for achieving diffraction-unlimited fluorescence microscopy in a cost-effective manner. Here, we demonstrate the successful upgrade of a commercial time-resolved confocal fluorescence microscope to an easy-to-align STED microscope in the single-beam path layout, previously proposed as "easy-STED", achieving lateral resolution < λ/10 corresponding to a five-fold improvement over a confocal modality. For this purpose, both the excitation and depletion laser beams pass through a commercially available segmented phase plate that creates the STED-doughnut light distribution in the focal plane, while leaving the excitation beam unaltered when implemented into the joint beam path. Diffraction-unlimited imaging of 20 nm-sized fluorescent beads as reference were achieved with the wavelength combination of 635 nm excitation and 766 nm depletion. To evaluate the STED performance in biological systems, we compared the popular phalloidin-coupled fluorescent dyes Atto647N and Abberior STAR635 by labeling F-actin filaments in vitro as well as through immunofluorescence recordings of microtubules in a complex epithelial tissue. Here, we applied a recently proposed deconvolution approach and showed that images obtained from time-gated pulsed STED microscopy may benefit concerning the signal-to-background ratio, from the joint deconvolution of sub-images with different spatial information which were extracted from offline time gating.

  6. Single-dose electron beam irradiation in treatment and prevention of keloids and hypertrophic scars

    International Nuclear Information System (INIS)

    Lo, T.C.M.; Salzman, F.A.; Seckel, B.R.; Wright, K.A.

    1990-01-01

    Low megavolt electron beam irradiation was used on 354 sites in 199 patients at Lahey Clinic either for palliation of symptomatic hypertrophic scars or as post operative irradiation in an attempt to prevent formation or recurrence of hypertrophic scars. Electron energies used ranged from 1.5 to 3.5 MeV. The median age of the 59 male patients was 22 years and of the 140 female patients 35 years. All patients had at least one follow-up visit, and the median follow-up was 35 months. Of the 294 sites treated for the first time, 272 (93 per cent) were irradiated with a single fraction with a skin dose ranging from 2 to 20 Gy. Of the 85 sites in 63 patients without excision of symptomatic hypertrophic scars, single-dose electron beam irradiation was of clinically significant value in only 41 sites (48 per cent). No patients have been treated without surgical excision since 1973. Because of a history of formation of hypertrophic scars elsewhere in the body, 13 patients with 19 incisions were treated prophylactically after operation for other diseases. All sites were irradiated with single doses ranging from 8 to 20 Gy, and hypertrophic scars did not subsequently develop in any patient. Altogether, 119 patients with 174 sites were irradiated after surgical excision of hypertrophic scars to prevent recurrence; 168 sites (97 per cent) received singe-fraction irradiation, and 161 received a dose of 8 Gy greater, up to 15 Gy. No statistically significant differences were observed in complete success rates, ranging from 82 to 90 per cent with doses of 9 Gy or greater. An interval of up to 72h between excision and single-fraction irradiation satisfactorily prevented recurrence, and clinically significant chronic telangiectasia was recorded in only one patient. Postoperative low megavolt electron beam irradiation with a single dose of 9 Gy or greater is highly effective in the prevention of formation recurrence of hypertrophic scars or keloids. (author). 31 refs.; 2 figs.; 4 tabs

  7. Single Bunch Electron Cloud Effects in the NLC Beam Delivery System(LCC-0126)

    Energy Technology Data Exchange (ETDEWEB)

    Chen, D

    2003-12-08

    A positron beam passing through a linear collider beam delivery beam line is finely focused to desired specifications during collimation and especially in Final Focusing (FFS). Undesired additional focusing is generated by beam-electron cloud interactions, which typically leads to beam size increases at high cloud densities. This paper examines the severity of the electron cloud effects and assesses the critical cloud density.

  8. Commissioning of the ATLAS High Level Trigger with single beam and cosmic rays

    Science.gov (United States)

    Di Mattia, A.; ATLAS Collaboration

    2010-04-01

    ATLAS is one of the two general-purpose detectors at the Large Hadron Collider (LHC). The trigger system is responsible for making the online selection of interesting collision events. At the LHC design luminosity of 1034 cm-2s-1 it will need to achieve a rejection factor of the order of 10-7 against random proton-proton interactions, while selecting with high efficiency events that are needed for physics analyses. After a first processing level using custom electronics based on FPGAs and ASICs, the trigger selection is made by software running on two processor farms, containing a total of around two thousand multi-core machines. This system is known as the High Level Trigger (HLT). To reduce the network data traffic and the processing time to manageable levels, the HLT uses seeded, step-wise reconstruction, aiming at the earliest possible rejection of background events. The recent LHC startup and short single-beam run provided a "stress test" of the system and some initial calibration data. Following this period, ATLAS continued to collect cosmic-ray events for detector alignment and calibration purposes. After giving an overview of the trigger design and its innovative features, this paper focuses on the experience gained from operating the ATLAS trigger with single LHC beams and cosmic-rays.

  9. Solution structure of an "open" E. coli Pol III clamp loader sliding clamp complex.

    Science.gov (United States)

    Tondnevis, Farzaneh; Weiss, Thomas M; Matsui, Tsutomu; Bloom, Linda B; McKenna, Robert

    2016-06-01

    Sliding clamps are opened and loaded onto primer template junctions by clamp loaders, and once loaded on DNA, confer processivity to replicative polymerases. Previously determined crystal structures of eukaryotic and T4 clamp loader-clamp complexes have captured the sliding clamps in either closed or only partially open interface conformations. In these solution structure studies, we have captured for the first time the clamp loader-sliding clamp complex from Escherichia coli using size exclusion chromatography coupled to small angle X-ray scattering (SEC-SAXS). The data suggests the sliding clamp is in an open conformation which is wide enough to permit duplex DNA binding. The data also provides information about spatial arrangement of the sliding clamp with respect to the clamp loader subunits and is compared to complex crystal structures determined from other organisms. Published by Elsevier Inc.

  10. The RFC clamp loader: structure and function.

    Science.gov (United States)

    Yao, Nina Y; O'Donnell, Mike

    2012-01-01

    The eukaryotic RFC clamp loader couples the energy of ATP hydrolysis to open and close the circular PCNA sliding clamp onto primed sites for use by DNA polymerases and repair factors. Structural studies reveal clamp loaders to be heteropentamers. Each subunit contains a region of homology to AAA+ proteins that defines two domains. The AAA+ domains form a right-handed spiral upon binding ATP. This spiral arrangement generates a DNA binding site within the center of RFC. DNA enters the central chamber through a gap between the AAA+ domains of two subunits. Specificity for a primed template junction is achieved by a third domain that blocks DNA, forcing it to bend sharply. Thus only DNA with a flexible joint can bind the central chamber. DNA entry also requires a slot in the PCNA clamp, which is opened upon binding the AAA+ domains of the clamp loader. ATP hydrolysis enables clamp closing and ejection of RFC, completing the clamp loading reaction.

  11. The RFC Clamp Loader: Structure and Function

    Science.gov (United States)

    O'Donnell, Mike

    2013-01-01

    The eukaryotic RFC clamp loader couples the energy of ATP hydrolysis to open and close the circular PCNA sliding clamp onto primed sites for use by DNA polymerases and repair factors. Structural studies reveal clamp loaders to be heteropentamers. Each subunit contains a region of homology to AAA+ proteins that defines two domains. The AAA+ domains form a right-handed spiral upon binding ATP. This spiral arrangement generates a DNA binding site within the center of RFC. DNA enters the central chamber through a gap between the AAA+ domains of two subunits. Specificity for a primed template junction is achieved by a third domain that blocks DNA, forcing it to bend sharply. Thus only DNA with a flexible joint can bind the central chamber. DNA entry also requires a slot in the PCNA clamp, which is opened upon binding the AAA+ domains of the clamp loader. ATP hydrolysis enables clamp closing and ejection of RFC, completing the clamp loading reaction. PMID:22918590

  12. Application of active electrode compensation to perform continuous voltage-clamp recordings with sharp microelectrodes.

    Science.gov (United States)

    Gómez-González, J F; Destexhe, A; Bal, T

    2014-10-01

    Electrophysiological recordings of single neurons in brain tissues are very common in neuroscience. Glass microelectrodes filled with an electrolyte are used to impale the cell membrane in order to record the membrane potential or to inject current. Their high resistance induces a high voltage drop when passing current and it is essential to correct the voltage measurements. In particular, for voltage clamping, the traditional alternatives are two-electrode voltage-clamp technique or discontinuous single electrode voltage-clamp (dSEVC). Nevertheless, it is generally difficult to impale two electrodes in a same neuron and the switching frequency is limited to low frequencies in the case of dSEVC. We present a novel fully computer-implemented alternative to perform continuous voltage-clamp recordings with a single sharp-electrode. To reach such voltage-clamp recordings, we combine an active electrode compensation algorithm (AEC) with a digital controller (AECVC). We applied two types of control-systems: a linear controller (proportional plus integrative controller) and a model-based controller (optimal control). We compared the performance of the two methods to dSEVC using a dynamic model cell and experiments in brain slices. The AECVC method provides an entirely digital method to perform continuous recording and smooth switching between voltage-clamp, current clamp or dynamic-clamp configurations without introducing artifacts.

  13. Generation and characterization of ultra-short electron beams for single spike infrared FEL radiation at SPARC_LAB

    Science.gov (United States)

    Villa, F.; Anania, M. P.; Artioli, M.; Bacci, A.; Bellaveglia, M.; Bisesto, F. G.; Biagioni, A.; Carpanese, M.; Cardelli, F.; Castorina, G.; Chiadroni, E.; Cianchi, A.; Ciocci, F.; Croia, M.; Curcio, A.; Dattoli, G.; Gallo, A.; Di Giovenale, D.; Di Palma, E.; Di Pirro, G.; Ferrario, M.; Filippi, F.; Giannessi, L.; Giribono, A.; Marocchino, A.; Massimo, F.; Mostacci, A.; Petralia, A.; Petrarca, M.; Petrillo, V.; Piersanti, L.; Pioli, S.; Pompili, R.; Romeo, S.; Rossi, A. R.; Scifo, J.; Shpakov, V.; Vaccarezza, C.

    2017-09-01

    The technique for producing and measuring few tens of femtosecond electron beams, and the consequent generation of few tens femtoseconds single spike FEL radiation pulses at SPARC_LAB is presented. The undulator has been used in the double role of radiation source and diagnostic tool for the characterization of the electron beam. The connection between the electron bunch length and the radiation bandwidth is analyzed.

  14. Radical distributions in ammonium tartrate single crystals exposed to photon and neutron beams

    International Nuclear Information System (INIS)

    Marrale, M.; Longo, A.; Brai, M.; Barbon, A.; Brustolon, M.

    2014-01-01

    The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with matter. The biological damages produced by ionising radiations in tissues and cells depend more properly on the energy released per unit pathlength, which is the linear energy transfer and which determines the radiation quality. To improve the therapy effectiveness, it is necessary to grasp the mechanisms of free radical production and distribution after irradiation with these particles when compared with the photon beams. In this work some preliminary results on the analysis of the spatial distributions of the free radicals produced after exposure of ammonium tartrate crystals to various radiation beams ( 60 Co gamma photons and thermal neutrons) were reported. Electron spin resonance analyses were performed by the electron spin echo technique, which allows the determination of local spin concentrations and by double electron-electron resonance technique, which is able to measure the spatial distance distribution (range 1.5-8 nm) among pairs of radicals in solids. The results of these analyses are discussed on the basis of the different distributions of free radicals produced by the two different radiation beams used. This paper extends to the single crystal case, a similar work done on AT powder irradiated with different beams, with assessment of microscopic radical concentration by determining the amount of ID contribution and obtaining the inter-radical distance distributions by double microwave irradiation. In this paper single crystals of AT have been exposed to 60 Co photons and neutrons. The results confirm that advanced pulse EPR techniques allow the direct measurement of the local free radical concentration and provide information about the

  15. Sizing Single Cantilever Beam Specimens for Characterizing Facesheet/Core Peel Debonding in Sandwich Structure

    Science.gov (United States)

    Ratcliffe, James G.

    2010-01-01

    This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.

  16. Single-particle And Collective Effects Of Cubic Nonlinearity In The Beam Dynamics Of Proton Synchrotrons

    CERN Document Server

    Tran Hy, J

    1998-01-01

    This thesis describes some new studies of the effects of cubic nonlinearities arising from image-charge forces and octupole magnets on the transverse beam dynamics of proton synchrotrons and storage rings, and also a study of the damping of coherent oscillations using a feed-back damper. In the latter case, various corrective algorithms were modeled using linear one-turn maps. Kicks of fixed amplitude but appropriate sign were shown to provide linear damping and no coherent tune shift, though the rate predicted analytically was somewhat higher than that observed in simulations. This algorithm gave much faster damping (for equal power) than conventional proportional kicks, which damp exponentially. Two single-particle effects of the image-change force were investigated: distortion of the momentum dispersion function and amplitude dependence of the betatron tunes (resulting in tune spread). The former is calculated using transfer maps and the method of undetermined coefficients, the latter by solving the cubic ...

  17. Three-dimensional polarization marked multiple-QR code encryption by optimizing a single vectorial beam

    Science.gov (United States)

    Lin, Chao; Shen, Xueju; Hua, Binbin; Wang, Zhisong

    2015-10-01

    We demonstrate the feasibility of three dimensional (3D) polarization multiplexing by optimizing a single vectorial beam using a multiple-signal window multiple-plane (MSW-MP) phase retrieval algorithm. Original messages represented with multiple quick response (QR) codes are first partitioned into a series of subblocks. Then, each subblock is marked with a specific polarization state and randomly distributed in 3D space with both longitudinal and transversal adjustable freedoms. A generalized 3D polarization mapping protocol is established to generate a 3D polarization key. Finally, multiple-QR code is encrypted into one phase only mask and one polarization only mask based on the modified Gerchberg-Saxton (GS) algorithm. We take the polarization mask as the cyphertext and the phase only mask as additional dimension of key. Only when both the phase key and 3D polarization key are correct, original messages can be recovered. We verify our proposal with both simulation and experiment evidences.

  18. Micro-particle manipulation by single beam acoustic tweezers based on hydrothermal PZT thick film

    International Nuclear Information System (INIS)

    Zhu, Benpeng; Xu, Jiong; Yang, Xiaofei; Li, Ying; Lee, Changyang; Zhou, Qifa; Shung, K. Kirk; Wang, Tian; Xiong, Ke; Shiiba, Michihisa; Takeuchi, Shinichi

    2016-01-01

    Single-beam acoustic tweezers (SBAT), used in laboratory-on-a-chip (LOC) device has promising implications for an individual micro-particle contactless manipulation. In this study, a freestanding hydrothermal PZT thick film with excellent piezoelectric property (d 33 = 270 pC/N and k t = 0.51) was employed for SBAT applications and a press-focusing technology was introduced. The obtained SBAT, acting at an operational frequency of 50 MHz, a low f-number (∼0.9), demonstrated the capability to trap and manipulate a micro-particle sized 10μm in the distilled water. These results suggest that such a device has great potential as a manipulator for a wide range of biomedical and chemical science applications.

  19. Characterisation of a cryostat using simultaneous, single-beam multiple-surface laser vibrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kissinger, Thomas; Charrett, Thomas O. H.; James, Stephen W.; Tatam, Ralph P., E-mail: r.p.tatam@cranfield.ac.uk [Engineering Photonics, Cranfield University, Cranfield, MK43 0AL (United Kingdom); Adams, Alvin; Twin, Andrew [Oxford Instruments Nanoscience, Tubney Woods, Abingdon, Oxon, OX13 5QX (United Kingdom)

    2016-06-28

    A novel range-resolved interferometric signal processing technique that uses sinusoidal optical frequency modulation is applied to multi-surface vibrometry, demonstrating simultaneous optical measurements of vibrations on two surfaces using a single, collimated laser beam, with a minimum permissible distance of 3.5 cm between surfaces. The current system, using a cost-effective laser diode and a fibre-coupled, downlead insensitive setup, allows an interferometric fringe rate of up to 180 kHz to be resolved with typical displacement noise levels of 8 pm · Hz{sup −05}. In this paper, the system is applied to vibrometry measurements of a table-top cryostat, with concurrent measurements of the optical widow and the sample holder target inside. This allows the separation of common-mode vibrations of the whole cryostat from differential vibrations between the window and the target, allowing any resonances to be identified.

  20. Novel single-beam optical spectrophotometer for fast luminescence, absorption, and reflection measurements of turbid materials

    Science.gov (United States)

    Schmidt, Werner

    1995-02-01

    A novel spectrophotometer based on the deflection of a secondary element for measuring clear and highly turbid materials within the millisecond time range is developed. The number of optical components of the monochromator is reduced to the absolute minimum. This results in excellent light throughput and a low stray-light level. The spectrophotometer has been designed allowing spectral measurements of absorption, transmission, reflection, and luminescence in a single-beam mode, as documented by various examples. Its design is highly flexible and the price/quality relation might be adopted to the envisaged purpose. The main philosophy is to relocate as many functions as possible form the hardware to the software part of the spectrophotometer. Several novel procedures based on old concepts are proposed. An appropriate computer program providing data acquisition, control functions as well as numerous analytical capabilities is developed on the basis of the compiler language power basic and indispensably 'fast' routines are written in assembler language.

  1. Focused ion beam milling of nanocavities in single colloidal particles and self-assembled opals

    International Nuclear Information System (INIS)

    Woldering, Leon A; Otter, A M; Husken, Bart H; Vos, Willem L

    2006-01-01

    We present a new method of realizing single nanocavities in individual colloidal particles on the surface of silicon dioxide artificial opals using a focused ion beam milling technique. We show that both the radius and the position of the nanocavity can be controlled with nanometre precision, to radii as small as 40 nm. The relation between the defect size and the milling time has been established. We confirmed that milling not only occurs on the surface of the spheres, but into and through them as well. We also show that an array of nanocavities can be fashioned. Structurally modified colloids have interesting potential applications in nanolithography, as well as in chemical sensing and solar cells, and as photonic crystal cavities

  2. Patch Clamp Experiments under Conditions of Variable Graviy

    Science.gov (United States)

    Kohn, F. P. M.; Meissner, K.

    2013-02-01

    The cellular membrane is an intrinsic part of any cell. It has a complex composition of lipid molecules and proteins. The membrane is, among others, involved in excitation and signal transduction. Ion channels, as integral membrane proteins, play an important role. For the question of gravity sensitivity of biological systems, especially neuronal cells, ion channels are of high interest. Gravity might directly interact with the ion channel protein or it might change the thermodynamic membrane parameters, influencing the incorporated proteins indirectly. Detailed information about the effects of gravity on the function of single ion-channels can up to now only be acquired by electrophysiological approaches like the patch clamp technique. Today this technique is the preferentially used technique for single ion-channel studies. Consequently, experiments have been developed in recent years to investigate the interaction of gravity with single ion channel molecules utilizing the patch-clamp technology on different macro- and micro-gravity platforms.

  3. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery.

    Science.gov (United States)

    Vriens, Bianca H R; Pol, Robert A; Hulsebos, Robin G; van Det, Rob J; van der Palen, Job; Zeebregts, Clark J; Geelkerken, Robert H

    2015-09-01

    To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inlay clamp and marked with an hemoclip. The number of pre-existing atherosclerotic segments, clamp force, and clamp time were recorded and the occurrence of a stenosis at the clamp site was determined. After a mean follow-up of 83 months, a significant stenosis was confirmed at 23 of the 178 clamp sites (12.9%; 95% confidence interval 8.4 to 18.8). The mean number of pre-existing atherosclerotic segments (P = .28) and the mean clamp force (P = .55) was similar between the groups with and without a stenosis. There was a significant difference regarding clamp time between the group with and without a stenosis (38 minutes and 26 minutes, P = .001). Arterial clamping, even with the Fogarty-Soft-Inlay clamp, can lead to clamp stenosis and seems to be related to the duration of clamping, but not to pre-existent atherosclerotic burden. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. A fully three-dimensional reconstruction algorithm with the nonstationary filter for improved single-orbit cone beam SPECT

    International Nuclear Information System (INIS)

    Cao, Z.J.; Tsui, B.M.

    1993-01-01

    Conventional single-orbit cone beam tomography presents special problems. They include incomplete sampling and inadequate three-dimensional (3D) reconstruction algorithm. The commonly used Feldkamp reconstruction algorithm simply extends the two-dimensional (2D) fan beam algorithm to 3D cone beam geometry. A truly 3D reconstruction formulation has been derived for the single-orbit cone beam SPECT based on the 3D Fourier slice theorem. In the formulation, a nonstationary filter which depends on the distance from the central plane of the cone beam was derived. The filter is applied to the 2D projection data in directions along and normal to the axis-of-rotation. The 3D reconstruction algorithm with the nonstationary filter was evaluated using both computer simulation and experimental measurements. Significant improvement in image quality was demonstrated in terms of decreased artifacts and distortions in cone beam reconstructed images. However, compared with the Feldkamp algorithm, a five-fold increase in processing time is required. Further improvement in image quality needs complete sampling in frequency space

  5. Archive of U.S. Geological Survey selected single-beam bathymetry datasets, 1969-2000

    Science.gov (United States)

    Schreppel, Heather A.; Degnan, Carolyn H.; Dadisman, Shawn V.; Metzger, Dan R.

    2013-01-01

    ) file and data file are created for each survey (Hittelman and others, 1977). More details about the MGD77T format are available at http://www.ngdc.noaa.gov/mgg/dat/geodas/docs/mgd77.pdf (74MB PDF). This archive describes the detailed steps used to convert single-beam bathymetry and navigation files into the MGD77T format (Hittelman and others, 1977) for submission to NGDC and formal Federal Geographic Data Committee (FGDC) (http://www.fgdc.gov/metadata) metadata as a publication of these single-beam bathymetry datasets.

  6. Investigation of the Dynamics of a Clamped-Clamped Microbeam Near the Third Mode Using a Partial Electrode

    KAUST Repository

    Masri, Karim M.

    2014-08-17

    We present an investigation of the dynamics of a clamped-clamped microbeam excited electrostatically near its third mode. To maximize the response at the third mode, a partial electrode configuration is utilized. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. A shooting method to find the periodic motion is utilized to generate frequency response curves. The curves show hardenining behavior and dynamic pull-in. We show that the dynamic amplitude of the partial configuration is higher than that of a full electrode configuration. These results are promising for the use of higher-order modes for mass detection and for ultra sensitive resonant sensors.

  7. To clamp or not to clamp? Long-term functional outcomes for elective off-clamp laparoscopic partial nephrectomy.

    Science.gov (United States)

    Shah, Paras H; George, Arvin K; Moreira, Daniel M; Alom, Manaf; Okhunov, Zhamshid; Salami, Simpa; Waingankar, Nikhil; Schwartz, Michael J; Vira, Manish A; Richstone, Lee; Kavoussi, Louis R

    2016-02-01

    To evaluate whether elective off-clamp laparoscopic partial nephrectomy (LPN) affords long-term renal functional benefit compared with the on-clamp approach. This is a retrospective review of patients who underwent elective LPN between 2006 and 2011. Patients were followed longitudinally for up to 5 years. In all, 315 patients with radiographic evidence of a solitary renal mass and normal-appearing contralateral kidney underwent elective LPN; 209 were performed on-clamp vs 106 off-clamp. One patient who required conversion from LPN to open PN was excluded from the study. Additionally, four patients in the on-clamp cohort who underwent subsequent radical nephrectomy for local-regional recurrence were excluded from longitudinal functional evaluation after their procedure. The primary objective was to evaluate differences in postoperative estimated glomerular filtration rate (eGFR) between hilar clamping groups. Subgroup analyses were performed for patients with clamp times >30 min and those with baseline renal insufficiency (eGFR clamp and off-clamp cohorts (80.7 vs 84.1 mL/min/1.73m(2) , P > 0.05). Univariable and multivariable analyses did not show significant differences in postoperative eGFR between both groups among all-comers, those with clamp times >30 min, and patients with baseline renal insufficiency. Risk of chronic kidney disease was not diminished by the off-clamp approach with up to 5 years of follow-up. Progressive recovery of renal function after hilar clamping in the elective setting eclipses short-term functional benefit achieved with off-clamp LPN by 6 months; there was no significant difference in eGFR or the percentage incidence of chronic kidney disease between the on-clamp and off-clamp cohorts with up to 5 years follow-up. As such, eliminating transient ischaemia during elective LPN does not confer clinical benefit. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  8. Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jonghwan; Pua, Rizza; Cho, Seungryong, E-mail: scho@kaist.ac.kr [Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Kim, Insoo; Han, Bumsoo [EB Tech, Co., Ltd., 550 Yongsan-dong, Yuseong-gu, Daejeon 305-500 (Korea, Republic of)

    2015-11-15

    Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the

  9. Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction.

    Science.gov (United States)

    Min, Jonghwan; Pua, Rizza; Kim, Insoo; Han, Bumsoo; Cho, Seungryong

    2015-11-01

    A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. The authors have successfully demonstrated that the proposed scanning method and image

  10. On the mechanism of loading the PCNA sliding clamp by RFC.

    Science.gov (United States)

    Dionne, Isabelle; Brown, Nicola J; Woodgate, Roger; Bell, Stephen D

    2008-04-01

    Sliding clamps play central roles in a broad range of DNA replication and repair processes. The clamps form circular molecules that must be opened and resealed around DNA by the clamp loader complex to fulfil their function. While most eukaryotes and many archea possess a homo-trimeric PCNA, the PCNA of Sulfolobus solfataricus is a heterotrimer. Here, we exploit the asymmetry of S. solfataricus PCNA to create a series of circularly permuted PCNA subunit fusions, thereby covalently closing defined interfaces within the heterotrimer. Using these concatamers, we investigate the requirements for loading the clamp onto DNA and reveal that a single defined interface within the heterotrimer is opened during the loading process. Subunit-specific interactions between S. solfataricus RFC clamp loader and PCNA permit us to superimpose our data upon the structure of yeast RFC-PCNA complex, thereby presenting a general model for PCNA loading by RFC in archaea and eukaryotes.

  11. Ring resonator-based single-chip 1x8 optical beam forming network in LPCVD waveguide technology

    NARCIS (Netherlands)

    Zhuang, L.; Roeloffzen, C.G.H.; Heideman, Rene; Borreman, A.; Meijerink, Arjan; van Etten, Wim; Koonen, A.M.J.; Leijtens, X.J.M.; van den Boom, H.P.A.; Verdurmen, E.J.M.; Molina Vázquez, J.

    2006-01-01

    Optical ring resonators (ORRs) are good candidates to provide continuously tunable delay in beam forming networks (BFNs) for phased array antenna systems. Delay and splitting/combining elements can be integrated on a single optical chip to form an OBFN. A state-of-the-art 1×8 OBFN chip has been

  12. Single-chip ring resonator-based 1 x 8 optical beam forming network in CMOS-compatible waveguide technology

    NARCIS (Netherlands)

    Zhuang, L.; Roeloffzen, C.G.H.; Heideman, Rene; Borreman, A.; Meijerink, Arjan; van Etten, Wim

    2007-01-01

    Optical ring resonators (ORRs) are good candidates to provide continuously tunable delay in optical beam forming networks (OBFNs) for phased array antenna systems. Delay and splitting/combining elements can be integrated on a single optical chip to form an OBFN. A state-of-the-art ring resonator-

  13. A single-beam titration method for the quantification of open-path Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Sung, Lung-Yu; Lu, Chia-Jung

    2014-01-01

    This study introduced a quantitative method that can be used to measure the concentration of analytes directly from a single-beam spectrum of open-path Fourier Transform Infrared Spectroscopy (OP-FTIR). The peak shapes of the analytes in a single-beam spectrum were gradually canceled (i.e., “titrated”) by dividing an aliquot of a standard transmittance spectrum with a known concentration, and the sum of the squared differential synthetic spectrum was calculated as an indicator for the end point of this titration. The quantity of a standard transmittance spectrum that is needed to reach the end point can be used to calculate the concentrations of the analytes. A NIST traceable gas standard containing six known compounds was used to compare the quantitative accuracy of both this titration method and that of a classic least square (CLS) using a closed-cell FTIR spectrum. The continuous FTIR analysis of industrial exhausting stack showed that concentration trends were consistent between the CLS and titration methods. The titration method allowed the quantification to be performed without the need of a clean single-beam background spectrum, which was beneficial for the field measurement of OP-FTIR. Persistent constituents of the atmosphere, such as NH 3 , CH 4 and CO, were successfully quantified using the single-beam titration method with OP-FTIR data that is normally inaccurate when using the CLS method due to the lack of a suitable background spectrum. Also, the synthetic spectrum at the titration end point contained virtually no peaks of analytes, but it did contain the remaining information needed to provide an alternative means of obtaining an ideal single-beam background for OP-FTIR. - Highlights: • Establish single beam titration quantification method for OP-FTIR. • Define the indicator for the end-point of spectrum titration. • An ideal background spectrum can be obtained using single beam titration. • Compare the quantification between titration

  14. Beam Normal Single Spin Asymmetry in Forward Angle Inelastic Electron-Proton Scattering using the Q-Weak Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    ., Nuruzzaman [Hampton Univ., Hampton, VA (United States)

    2014-12-01

    The Q-weak experiment in Hall-C at the Thomas Jefferson National Accelerator Facility has made the first direct measurement of the weak charge of the proton through the precision measurement of the parity-violating asymmetry in elastic electron-proton scattering at low momentum transfer. There is also a parity conserving Beam Normal Single Spin Asymmetry or transverse asymmetry (B_n) on H_2 with a sin(phi)-like dependence due to two-photon exchange. If the size of elastic B_n is a few ppm, then a few percent residual transverse polarization in the beam, combined with small broken azimuthal symmetries in the detector, would require a few ppb correction to the Q-weak data. As part of a program of B_n background studies, we made the first measurement of B_n in the N-to-Delta(1232) transition using the Q-weak apparatus. The final transverse asymmetry, corrected for backgrounds and beam polarization, was found to be B_n = 42.82 ± 2.45 (stat) ± 16.07 (sys) ppm at beam energy E_beam = 1.155 GeV, scattering angle theta = 8.3 deg, and missing mass W = 1.2 GeV. B_n from electron-nucleon scattering is a unique tool to study the gamma^* Delta Delta form factors, and this measurement will help to improve the theoretical models on beam normal single spin asymmetry and thereby our understanding of the doubly virtual Compton scattering process. To help correct false asymmetries from beam noise, a beam modulation system was implemented to induce small position, angle, and energy changes at the target to characterize detector response to the beam jitter. Two air-core dipoles separated by ~10 m were pulsed at a time to produce position and angle changes at the target, for virtually any tune of the beamline. The beam energy was modulated using an SRF cavity. The hardware and associated control instrumentation will be described in this dissertation. Preliminary detector sensitivities were extracted which helped to reduce the width of the measured asymmetry. The beam modulation system

  15. A robust single-beam optical trap for a gram-scale mechanical oscillator.

    Science.gov (United States)

    Altin, P A; Nguyen, T T-H; Slagmolen, B J J; Ward, R L; Shaddock, D A; McClelland, D E

    2017-11-06

    Precise optical control of microscopic particles has been mastered over the past three decades, with atoms, molecules and nano-particles now routinely trapped and cooled with extraordinary precision, enabling rapid progress in the study of quantum phenomena. Achieving the same level of control over macroscopic objects is expected to bring further advances in precision measurement, quantum information processing and fundamental tests of quantum mechanics. However, cavity optomechanical systems dominated by radiation pressure - so-called 'optical springs' - are inherently unstable due to the delayed dynamical response of the cavity. Here we demonstrate a fully stable, single-beam optical trap for a gram-scale mechanical oscillator. The interaction of radiation pressure with thermo-optic feedback generates damping that exceeds the mechanical loss by four orders of magnitude. The stability of the resultant spring is robust to changes in laser power and detuning, and allows purely passive self-locking of the cavity. Our results open up a new way of trapping and cooling macroscopic objects for optomechanical experiments.

  16. Geometry modeling of single track cladding deposited by high power diode laser with rectangular beam spot

    Science.gov (United States)

    Liu, Huaming; Qin, Xunpeng; Huang, Song; Hu, Zeqi; Ni, Mao

    2018-01-01

    This paper presents an investigation on the relationship between the process parameters and geometrical characteristics of the sectional profile for the single track cladding (STC) deposited by High Power Diode Laser (HPDL) with rectangle beam spot (RBS). To obtain the geometry parameters, namely cladding width Wc and height Hc of the sectional profile, a full factorial design (FFD) of experiment was used to conduct the experiments with a total of 27. The pre-placed powder technique has been employed during laser cladding. The influence of the process parameters including laser power, powder thickness and scanning speed on the Wc and Hc was analyzed in detail. A nonlinear fitting model was used to fit the relationship between the process parameters and geometry parameters. And a circular arc was adopted to describe the geometry profile of the cross-section of STC. The above models were confirmed by all the experiments. The results indicated that the geometrical characteristics of the sectional profile of STC can be described as the circular arc, and the other geometry parameters of the sectional profile can be calculated only using Wc and Hc. Meanwhile, the Wc and Hc can be predicted through the process parameters.

  17. Commissioning of the ATLAS high-level trigger with single beam and cosmic rays

    Science.gov (United States)

    Erkcan Özcan, V.

    2010-11-01

    ATLAS is one of the two general-purpose detectors at the Large Hadron Collider (LHC). Using fast reconstruction algorithms, its trigger system needs to efficiently reject a huge rate of background events and still select potentially interesting ones with good efficiency. After a first processing level using custom electronics, the trigger selection is made by software running on two processor farms, designed to have a total of around two thousand multi-core machines. This system is known as the High Level Trigger (HLT). To reduce the network data traffic and the processing time to manageable levels, the HLT uses seeded, step-wise reconstruction, aiming at the earliest possible rejection of background events. The recent LHC startup and short single-beam run provided a "stress test" of the trigger. Following this period, ATLAS continued to collect cosmic-ray events for detector alignment and calibration purposes. These running periods allowed strict tests of the HLT reconstruction and selection algorithms as well as of its configuration and monitoring systems. This facilitated the commissioning of several tracking, muon-finding, and calorimetry algorithms under different running conditions. After an overview of the trigger design, this paper focuses on the experience gained in running the trigger in the fast-changing environment of the detector commissioning. It will emphasize the commissioning of the HLT algorithms, monitoring and configuration.

  18. Commissioning of the ATLAS high-level trigger with single beam and cosmic rays

    International Nuclear Information System (INIS)

    Erkcan Ozcan, V.

    2010-01-01

    ATLAS is one of the two general-purpose detectors at the Large Hadron Collider (LHC). Using fast reconstruction algorithms, its trigger system needs to efficiently reject a huge rate of background events and still select potentially interesting ones with good efficiency. After a first processing level using custom electronics, the trigger selection is made by software running on two processor farms, designed to have a total of around two thousand multi-core machines. This system is known as the High Level Trigger (HLT). To reduce the network data traffic and the processing time to manageable levels, the HLT uses seeded, step-wise reconstruction, aiming at the earliest possible rejection of background events. The recent LHC startup and short single-beam run provided a 'stress test' of the trigger. Following this period, ATLAS continued to collect cosmic-ray events for detector alignment and calibration purposes. These running periods allowed strict tests of the HLT reconstruction and selection algorithms as well as of its configuration and monitoring systems. This facilitated the commissioning of several tracking, muon-finding, and calorimetry algorithms under different running conditions. After an overview of the trigger design, this paper focuses on the experience gained in running the trigger in the fast-changing environment of the detector commissioning. It will emphasize the commissioning of the HLT algorithms, monitoring and configuration.

  19. Single-beam bathymetry data collected in 2015 from Grand Bay, Alabama-Mississippi

    Science.gov (United States)

    DeWitt, Nancy T.; Stalk, Chelsea A.; Smith, Christopher G.; Locker, Stanley D.; Fredericks, Jake J.; McCloskey, Terrence A.; Wheaton, Cathryn J.

    2017-12-01

    As part of the Sea-level and Storm Impacts on Estuarine Environments and Shorelines (SSIEES) project, scientists from the U.S. Geological Survey (USGS) St. Petersburg Coastal and Marine Science Center conducted a single-beam bathymetry survey within the estuarine, open-bay, and tidal creek environments of Grand Bay, Alabama-Mississippi, from May to June 2015. The goal of the SSIEES project is to assess the physical controls of sediment and material exchange between wetlands and estuarine environments along the northern Gulf of Mexico, specifically Grand Bay, Alabama-Mississippi; Vermilion Bay, Louisiana; and, along the east coast, within Chincoteague Bay, Virginia-Maryland. The data described in this report provide baseline bathymetric information for future research investigating wetland-marsh evolution, sediment transport, erosion, recent and long-term geomorphic change, and can also support the modeling of changes in response to restoration and storm impacts. The survey area encompasses more than 40 square kilometers of Grand Bay’s waters.

  20. Single and multichannel scintillating fiber dosimeter for radiotherapic beams with SiPM readout

    Energy Technology Data Exchange (ETDEWEB)

    Berra, A., E-mail: alessandro.berra@gmail.it [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca (Italy); Ferri, A. [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (Italy); Novati, C. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca (Italy); Ostinelli, A. [Ospedale Sant' Anna, Servizio di Fisica Sanitaria (Italy); Paternoster, G.; Piemonte, C. [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi (Italy); Prest, M. [Università degli Studi dell' Insubria e INFN sezione di Milano Bicocca (Italy); Vallazza, E. [INFN Sezione di Trieste (Italy)

    2016-12-01

    The treatment of many neoplastic diseases requires the use of radiotherapy, which consists in the irradiation of the tumor, identified as the target volume, with ionizing radiations generated both by administered radiopharmaceuticals or by linear particle accelerators (LINACs). The radiotherapy beam delivered to the patient must be regularly checked to assure the best tumor control probability: this task is performed with dosimeters, i.e. devices able to provide a measurement of the dose deposited in their sensitive volume. This paper describes the development of two scintillator dosimeter prototypes for radiotherapic applications based on plastic scintillating fibers read out by high dynamic range Silicon PhotoMultipliers. The first dosimeter, consisting of a single-channel prototype with a pair of optical fibers, a scintillating and a white one, read out by two SiPMs, has been fully characterized and led to the development of a second multi-channel dosimeter based on an array of scintillating fibers: this device represents the first step towards the assembly of a “one-shot” device, capable to perform some of the daily quality controls in a few seconds. The dosimeters characterization was performed with a Varian Clinac iX linear accelerator at the Radiotherapy Department of the St. Anna Hospital in Como (IT).

  1. AN ELASTIC STRESS ANALYSIS FOR A POLYMER MATRIX COMPOSITE CANTILEVER BEAM SUBJECTED TO A SINGLE TRANSVERSE FORCE

    Directory of Open Access Journals (Sweden)

    Ayla TEKİN

    2004-03-01

    Full Text Available In this study, elasto-plastic stress analysis is carried out in a polymer matrix composite cantilever beam of arbitrary fiber orientation subjected to a single transverse force applied to the free end by using the anisotropic elasticity theory. The residual stress component of ?x and yield points are determined for 0°, 30°, 45°, 60° and 90° fiber orientation angles. The yielding begins for 0° and 90° fiber orientation angles at the upper and lower surfaces of the beam at the same distances from the free end. It is seen that the yielding begins for 30°, 45° and 60° fiber orientation angles at the upper surface of the beam. The intensity of the residual stress component of ?x is maximum at the upper and lower surfaces of the beam. In this study, the residual stress component of ?x obtained for the polymer matrix composite thermoplastic cantilever beam reinforced by reinforced unidirectional fibers is compared with that of the thermoplastic cantilever beam reinforced by woven Cr-Ni steel fibers.

  2. Direct generation of an optical vortex beam in a single-frequency Nd:YVO4 laser.

    Science.gov (United States)

    Kim, D J; Kim, J W

    2015-02-01

    A simple method for generating a Laguerre-Gaussian (LG) mode optical vortex beam with well-determined handedness in a single-frequency solid state laser end-pumped by a ring-shaped pump beam is reported. After investigating the intensity profile and the wavefront helicity of each longitudinal mode output to understand generation of the LG mode in a Nd:YVO4 laser resonator, selection of the wavefront handedness has been achieved simply by inserting and tilting an etalon in the resonator, which breaks the propagation symmetry of the Poynting vectors with opposite helicity. Simple calculation and the experimental results are discussed for supporting this selection mechanism.

  3. Acoustic characterization of continental shelf seafloor and benthic habitats using single and multi-beam backscatter data

    Digital Repository Service at National Institute of Oceanography (India)

    Haris, K.; Chakraborty, B.

    -frequency single-beam and multi-beam echo-sounders has been recognized as an effective tool to characterize the seafloor over a wide area. The acoustic backscatter data obtained from such echo-sounding systems can be matched with theoretical scattering models... to interpret the information embedded in the data [1-4]. The numerical approach employed for extracting information from the data is commonly referred to as ‘inversion modeling’. The inversion modeling primarily involves physics based inversion of echo-sounding...

  4. Measurements of the evaporation and hygroscopic response of single fine-mode aerosol particles using a Bessel beam optical trap.

    Science.gov (United States)

    Cotterell, Michael I; Mason, Bernard J; Carruthers, Antonia E; Walker, Jim S; Orr-Ewing, Andrew J; Reid, Jonathan P

    2014-02-07

    A single horizontally-propagating zeroth order Bessel laser beam with a counter-propagating gas flow was used to confine single fine-mode aerosol particles over extended periods of time, during which process measurements were performed. Particle sizes were measured by the analysis of the angular variation of light scattered at 532 nm by a particle in the Bessel beam, using either a probe beam at 405 nm or 633 nm. The vapour pressures of glycerol and 1,2,6-hexanetriol particles were determined to be 7.5 ± 2.6 mPa and 0.20 ± 0.02 mPa respectively. The lower volatility of hexanetriol allowed better definition of the trapping environment relative humidity profile over the measurement time period, thus higher precision measurements were obtained compared to those for glycerol. The size evolution of a hexanetriol particle, as well as its refractive index at wavelengths 532 nm and 405 nm, were determined by modelling its position along the Bessel beam propagation length while collecting phase functions with the 405 nm probe beam. Measurements of the hygroscopic growth of sodium chloride and ammonium sulfate have been performed on particles as small as 350 nm in radius, with growth curves well described by widely used equilibrium state models. These are the smallest particles for which single-particle hygroscopicity has been measured and represent the first measurements of hygroscopicity on fine mode and near-accumulation mode aerosols, the size regimes bearing the most atmospheric relevance in terms of loading, light extinction and scattering. Finally, the technique is contrasted with other single particle and ensemble methods, and limitations are assessed.

  5. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  6. State of the art of pipe clamp analysis

    International Nuclear Information System (INIS)

    Fang, P.J.

    1984-01-01

    Various types of clamps are used as a component of piping support structures in nuclear power plants. The clamp is referred to as a nonintegral attachment to pipe in contrast to lugs which are integrally welded to the pipe wall. An analysis to determine the load capacity of a clamp is complicated by the fact that the distribution of contact stresses acting on the clamp-pipe interface is a nonlinearly dependent on the geometry of the clamp and pipe, clamping force preapplied to the clamp, and external loads. This paper reviews various methods of clamp analysis including both the closed-formed solutions and the finite element approach. While conventional two- and three-bolt clamps for a horizontal pipe run are emphasized, stiff clamps and riser clamps are also discussed. Finally, the potential effects of interaction between the clamp and pipe are evaluated. (Author) [pt

  7. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  8. Single-mirror beam steering system: analysis and synthesis of high-order conic-section scan patterns

    Science.gov (United States)

    Li, Yajun

    2008-01-01

    The vector approach introduced in an early paper for modeling mirror-scanning devices [Y. Li, Appl. Opt. 34, 6417 (1995)] provides the basis of a rigorous study of the scan field generated by a single-mirror beam steering system, in which a hinged movable mirror is able to turn about a fixed pivot point to steering a single laser beam. Because of fewer constraints on mirror angular motion, the system may behave like a true point source for both vector and raster scanning applications. After a summary of the expressions for scan fields generated under different conditions, some fundamental and advanced topics of the single-mirror system are addressed: (1) basic parameters of high-order conic-section scan patterns, (2) scanning spot kinematics, (3) effect of input offset and pixels distortions on two-dimensional images displayed on screens of different formats, (4) mapping and its inverse between the mirror vector space and the scan vector space, and (5) single-mirror beam steering system as a one-element reflective and continuous image zooming device.

  9. The number of beams in IMRT-theoretical investigations and implications for single-arc IMRT

    International Nuclear Information System (INIS)

    Bortfeld, Thomas

    2010-01-01

    The first purpose of this paper is to shed some new light on the old question of selecting the number of beams in intensity-modulated radiation therapy (IMRT). The second purpose is to illuminate the related issue of discrete static beam angles versus rotational techniques, which has recently re-surfaced due to the advancement of volumetric modulated arc therapy (VMAT). A specific objective is to find analytical expressions that allow one to address the points raised above. To make the problem mathematically tractable, it is assumed that the depth dose is flat and that the lateral dose profile can be approximated by polynomials, specifically Chebyshev polynomials of the first kind, of finite degree. The application of methods known from image reconstruction then allows one to answer the first question above as follows: the required number of beams is determined by the maximum degree of the polynomials used in the approximation of the beam profiles, which is a measure of the dose variability. There is nothing to be gained by using more beams. In realistic cases, in which the variability of the lateral dose profile is restricted in several ways, the required number of beams is of the order of 10-20. The consequence of delivering the beams with a 'leaf sweep' technique during continuous rotation of the gantry, as in VMAT, is also derived in an analytical form. The main effect is that the beams fan out, but the effect near the axis of rotation is small. This result can serve as a theoretical justification of VMAT. Overall the analytical derivations in this paper, albeit based on strong simplifications, provide new insights into, and a deeper understanding of, the beam angle problem in IMRT. The decomposition of the beam profiles into well-behaved and easily deliverable smooth functions, such as Chebyshev polynomials, could be of general interest in IMRT treatment planning.

  10. The effect of a single blade limiter on energetic neutral beam particles in Doublet III

    International Nuclear Information System (INIS)

    Petrie, T.W.; Armentrout, C.; Burrell, K.H.; Hino, T.; Kahn, C.; Kim, J.; Lohr, J.; Rottler, L.; Schissel, D.; St John, H.

    1984-01-01

    Energetic beam ion collisions with the main limiter can be a significant power loss process under certain operating conditions in Doublet III. Futhermore, these collisions may cause measurable damage to the limiter itself. Under low current and low toroidal field conditions (e.g., Isub(p) = 290 kA and Bsub(T) = 6.3 kG), 20-38% of the inferred absorbed beam power may be deposited directly on the ion drift side of the limiter by the beam ions. However, for higher plasma current and toroidal fields (e.g., Isub(p) = 480 kA and Bsub(t) = 15 kG), the fraction of inferred absorbed beam power deposited on the limiter is reduced to < 10%. Monte Carlo code simulations show that this loss of beam power is primarily a result of the large poloidal and toroidal gyro-orbits of the energetic beam ions. Other factors which may enhance beam ion losses to the limiter are (1) large separation distances between the primary limiter and the (outboard) vacuum vessel wall, and (2) plasma density buildup near the plasma edge during high gas puff operation. In addition, our data suggests enhanced plasma density and recycling near the limiter. This localized density can cause appreciable premature ionizations of the incoming beam neutrals and thus reduce the effective plasma heating of the beamline which is immediately upcurrent of the limiter. The prematurely-ionized beam particles from this adjacent beamline are responsible for much of the damage to the ion drift side of the limiter. We have found that under certain operating conditions (1) the direct beam heating of the limiter is 50% greater and (2) the stored plasma energy is 10% less when the beamline immediately upcurrent of the limiter heats the plasma. Thus, the relative positions of the limiters to the beamlines are important in designing future tokamaks. (orig.)

  11. An evaluation testing technique of single event effect using Beam Blanking SEM

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, J.; Hada, T.; Pesce, A.; Akutsu, T.; Matsuda, S. [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Igarashi, T.; Baba, S.

    1997-03-01

    Beam Blanking SEM (Scanning Electron Microscope) testing technique has been applied to CMOS SRAM devices to evaluate the occurence of soft errors on memory cells. Cross-section versus beam current and LET curves derived from BBSEM and heavy ion testing technique, respectively, have been compared. A linear relation between BBSEM current and heavy ion LET has been found. The purpose of this study was to demonstrate that the application of focused pulsed electron beam could be a reliable, convenient and inexpensive tool to investigate the effects of heavy ions and high energy particles on memory devices for space application. (author)

  12. A missing factor in chip-based patch clamp assay: gigaseal

    International Nuclear Information System (INIS)

    Ong, W-L; Yobas, L; Ong, W-Y

    2006-01-01

    The 'gold' standard in the study of ionic currents across biological membranes is the Patch Clamp method. However, this is a slow, labor and skill intensive process. High throughput patch clamp devices are mainly chip-based. A major challenge in these miniaturized devices is the low rate of 'Gigaseal' formation which is critical in the study of Single Channel effect. In a conventional patch clamp, a pipette moves and patches a fixed cell (cell-adhered patch) which is grown on the bottom of a Petri dish. In the chip-based case, the cells are in suspension and move towards the fixed patch clamp sites (cell-suspended patch). In this study, using the proven conventional patch clamp setup, we investigated the effect of the differences in the cell configurations between the convention patch clamp and cell-based patch clamp. It is shown that adhered cells (as used in the conventional setup) have a much higher rate of gigaseal formation as compared to the cells in suspension (as used in chip-based devices). We postulate that the arrangement of the cytoskeleton within the cell plays a major part in the formation of the gigaseal

  13. Molecular Mechanisms of DNA Polymerase Clamp Loaders

    Science.gov (United States)

    Kelch, Brian; Makino, Debora; Simonetta, Kyle; O'Donnell, Mike; Kuriyan, John

    Clamp loaders are ATP-driven multiprotein machines that couple ATP hydrolysis to the opening and closing of a circular protein ring around DNA. This ring-shaped clamp slides along DNA, and interacts with numerous proteins involved in DNA replication, DNA repair and cell cycle control. Recently determined structures of clamp loader complexes from prokaryotic and eukaryotic DNA polymerases have revealed exciting new details of how these complex AAA+ machines perform this essential clamp loading function. This review serves as background to John Kuriyan's lecture at the 2010 Erice School, and is not meant as a comprehensive review of the contributions of the many scientists who have advanced this field. These lecture notes are derived from recent reviews and research papers from our groups.

  14. Core clamping device for a nuclear reactor

    International Nuclear Information System (INIS)

    Guenther, R.W.

    1974-01-01

    The core clamping device for a fast neutron reactor includes clamps to support the fuel zone against the pressure vessel. The clamps are arranged around the circumference of the core. They consist of torsion bars arranged parallel at some distance around the core with lever arms attached to the ends whose force is directed in the opposite direction, pressing against the wall of the pressure vessel. The lever arms and pressure plates also actuated by the ends of the torsion bars transfer the stress, the pressure plates acting upon the fuel elements or fuel assemblies. Coupling between the ends of the torsion bars and the pressure plates is achieved by end carrier plates directly attached to the torsion bars and radially movable. This clamping device follows the thermal expansions of the core, allows specific elements to be disengaged in sections and saves space between the core and the neutron reflectors. (DG) [de

  15. Formal Design Review Foot Clamp Modification

    International Nuclear Information System (INIS)

    OTEN, T.C.

    2000-01-01

    This report documents the Design Review performed for the foot clamp modification. The report documents the acceptability of the design, identifies the documents that were reviewed, the scope of the review and the members of the review team

  16. Clamp force and alignment checking device

    Science.gov (United States)

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-04-11

    A check fixture measures a total clamp force applied by a welder device. The welder device includes a welding horn having a plurality of weld pads and welding anvil having a plurality of weld pads. The check fixture includes a base member operatively supporting a plurality of force sensors. The base member and the force sensors are received between the weld pads of the welding horn and the anvil pads of the welding anvil. Each force sensor is configured to measure an individual clamp force applied thereto by corresponding weld and anvil pads when the base member is received between the welding horn and the welding anvil and the welder device is in the clamped position. The individual clamp forces are used to determine whether the weld and/or anvil pads are worn or misaligned.

  17. Single-shot beam-position monitor for x-ray free electron laser

    Science.gov (United States)

    Tono, Kensuke; Kudo, Togo; Yabashi, Makina; Tachibana, Takeshi; Feng, Yiping; Fritz, David; Hastings, Jerome; Ishikawa, Tetsuya

    2011-02-01

    We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 μm by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL.

  18. Three-dimensional single-photon emission computed tomography using cone beam collimation (CB-SPECT)

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Floyd, C.E. Jr.; Manglos, S.H.; Greer, K.L.; Coleman, R.E.

    1986-01-01

    A simple and economically practical method of improving the sensitivity of camera-based SPECT was developed using converging (cone-beam) collimation. This geometry is particularly advantageous for SPECT devices using large field-of-view cameras in imaging smaller, centrally located activity distributions. Geometric sensitivities, spatial resolutions, and fields-of-view of a cone-beam collimator having a focal length of 48 cm and a similarly designed parallel hole collimator were compared analytically. At 15 cm from the collimator surface the point-source sensitivity of the cone-beam collimator was 2.4 times the sensitivity of the parallel-hole collimator. SPECT projection data (simulated using Monte Carlo methodology) were reconstructed using a 3-D filtered backprojection algorithm. Cone-beam emission CT (CB-SPECT) seems potentially useful for animal investigations, pediatric studies, and for brain imaging

  19. Simplified modelling and analysis of a rotating Euler-Bernoulli beam with a single cracked edge

    Science.gov (United States)

    Yashar, Ahmed; Ferguson, Neil; Ghandchi-Tehrani, Maryam

    2018-04-01

    The natural frequencies and mode shapes of the flapwise and chordwise vibrations of a rotating cracked Euler-Bernoulli beam are investigated using a simplified method. This approach is based on obtaining the lateral deflection of the cracked rotating beam by subtracting the potential energy of a rotating massless spring, which represents the crack, from the total potential energy of the intact rotating beam. With this new method, it is assumed that the admissible function which satisfies the geometric boundary conditions of an intact beam is valid even in the presence of a crack. Furthermore, the centrifugal stiffness due to rotation is considered as an additional stiffness, which is obtained from the rotational speed and the geometry of the beam. Finally, the Rayleigh-Ritz method is utilised to solve the eigenvalue problem. The validity of the results is confirmed at different rotational speeds, crack depth and location by comparison with solid and beam finite element model simulations. Furthermore, the mode shapes are compared with those obtained from finite element models using a Modal Assurance Criterion (MAC).

  20. Sound absorption by clamped poroelastic plates.

    Science.gov (United States)

    Aygun, H; Attenborough, K

    2008-09-01

    Measurements and predictions have been made of the absorption coefficient and the surface acoustic impedance of poroelastic plates clamped in a large impedance tube and separated from the rigid termination by an air gap. The measured and predicted absorption coefficient and surface impedance spectra exhibit low frequency peaks. The peak frequencies observed in the absorption coefficient are close to those predicted and measured in the deflection spectra of the clamped poroelastic plates. The influences of the rigidity of the clamping conditions and the width of the air gap have been investigated. Both influences are found to be important. Increasing the rigidity of clamping reduces the low frequency absorption peaks compared with those measured for simply supported plates or plates in an intermediate clamping condition. Results for a closed cell foam plate and for two open cell foam plates made from recycled materials are presented. For identical clamping conditions and width of air gap, the results for the different materials differ as a consequence mainly of their different elasticity, thickness, and cell structure.

  1. The essential Drosophila CLAMP protein differentially regulates non-coding roX RNAs in male and females.

    Science.gov (United States)

    Urban, Jennifer A; Doherty, Caroline A; Jordan, William T; Bliss, Jacob E; Feng, Jessica; Soruco, Marcela M; Rieder, Leila E; Tsiarli, Maria A; Larschan, Erica N

    2017-06-01

    Heterogametic species require chromosome-wide gene regulation to compensate for differences in sex chromosome gene dosage. In Drosophila melanogaster, transcriptional output from the single male X-chromosome is equalized to that of XX females by recruitment of the male-specific lethal (MSL) complex, which increases transcript levels of active genes 2-fold. The MSL complex contains several protein components and two non-coding RNA on the X ( roX) RNAs that are transcriptionally activated by the MSL complex. We previously discovered that targeting of the MSL complex to the X-chromosome is dependent on the chromatin-linked adapter for MSL proteins (CLAMP) zinc finger protein. To better understand CLAMP function, we used the CRISPR/Cas9 genome editing system to generate a frameshift mutation in the clamp gene that eliminates expression of the CLAMP protein. We found that clamp null females die at the third instar larval stage, while almost all clamp null males die at earlier developmental stages. Moreover, we found that in clamp null females roX gene expression is activated, whereas in clamp null males roX gene expression is reduced. Therefore, CLAMP regulates roX abundance in a sex-specific manner. Our results provide new insights into sex-specific gene regulation by an essential transcription factor.

  2. Nonlinear Phenomena in the Single-Mode Dynamics in an AFM Cantilever Beam

    KAUST Repository

    Ruzziconi, Laura

    2016-12-05

    This study deals with the nonlinear dynamics arising in an atomic force microscope cantilever beam. After analyzing the static behavior, a single degree of freedom Galerkin reduced order model is introduced, which describes the overall scenario of the structure response in a neighborhood of the primary resonance. Extensive numerical simulations are performed when both the forcing amplitude and frequency are varied, ranging from low up to elevated excitations. The coexistence of competing attractors with different characteristics is analyzed. Both the non-resonant and the resonant behavior are observed, as well as ranges of inevitable escape. Versatility of behavior is highlighted, which may be attractive in applications. Special attention is devoted to the effects of the tip-sample separation distance, since this aspect is of fundamental importance to understand the operation of an AFM. We explore the metamorphoses of the multistability region when the tip-sample separation distance is varied. To have a complete description of the AFM response, comprehensive behavior charts are introduced to detect the theoretical boundaries of appearance and disappearance of the main attractors. Also, extensive numerical simulations investigate the AFM response when both the forcing amplitude and the tip-sample separation distance are considered as control parameters. The main features are analyzed in detail and the obtained results are interpreted in terms of oscillations of the cantilever-tip ensemble. However, we note that all the aforementioned results represent the limit when disturbances are absent, which never occurs in practice. Here comes the importance of overcoming local investigations and exploring dynamics from a global perspective, by introducing dynamical integrity concepts. To extend the AFM results to the practical case where disturbances exist, we develop a dynamical integrity analysis. After performing a systematic basin of attraction analysis, integrity

  3. Physical characterization of single convergent beam device for teletherapy: theoretical and Monte Carlo approach.

    Science.gov (United States)

    Figueroa, R G; Valente, M

    2015-09-21

    The main purpose of this work is to determine the feasibility and physical characteristics of a new teletherapy device of radiation therapy based on the application of a convergent x-ray beam of energies like those used in radiotherapy providing highly concentrated dose delivery to the target. We have denominated it Convergent Beam Radio Therapy (CBRT). Analytical methods are developed first in order to determine the dosimetry characteristic of an ideal convergent photon beam in a hypothetical water phantom. Then, using the PENELOPE Monte Carlo code, a similar convergent beam that is applied to the water phantom is compared with that of the analytical method. The CBRT device (Converay(®)) is designed to adapt to the head of LINACs. The converging beam photon effect is achieved thanks to the perpendicular impact of LINAC electrons on a large thin spherical cap target where Bremsstrahlung is generated (high-energy x-rays). This way, the electrons impact upon various points of the cap (CBRT condition), aimed at the focal point. With the X radiation (Bremsstrahlung) directed forward, a system of movable collimators emits many beams from the output that make a virtually definitive convergent beam. Other Monte Carlo simulations are performed using realistic conditions. The simulations are performed for a thin target in the shape of a large, thin, spherical cap, with an r radius of around 10-30 cm and a curvature radius of approximately 70 to 100 cm, and a cubed water phantom centered in the focal point of the cap. All the interaction mechanisms of the Bremsstrahlung radiation with the phantom are taken into consideration for different energies and cap thicknesses. Also, the magnitudes of the electric and/or magnetic fields, which are necessary to divert clinical-use electron beams (0.1 to 20 MeV), are determined using electromagnetism equations with relativistic corrections. This way the above-mentioned beam is manipulated and guided for its perpendicular impact

  4. Use of the Satinsky clamp for hilar clamping during robotic partial nephrectomy: indications, technique, and multi-center outcomes.

    Science.gov (United States)

    Abdullah, Newaj; Rahbar, Haider; Barod, Ravi; Dalela, Deepansh; Larson, Jeff; Johnson, Michael; Mass, Alon; Zargar, Homayoun; Kaouk, Jihad; Allaf, Mohamad; Bhayani, Sam; Stifelman, Michael; Rogers, Craig

    2017-03-01

    A Satinsky clamp may be a backup option for hilar clamping during robotic partial nephrectomy (RPN) if there are challenges with application of bulldog clamps, but there are potential safety concerns. We evaluate outcomes of RPN using Satinsky vs. bulldog clamps, and provide tips for safe use of the Satinsky as a backup option. Using a multi-center database, we identified 1073 patients who underwent RPN between 2006 and 2013, and had information available about method of hilar clamping (bulldog clamp vs. Satinsky clamp). Patient baseline characteristics, tumor features, and perioperative outcomes were compared between the Satinsky and bulldog clamp groups. A Satinsky clamp was used for hilar clamping in 94 (8.8 %) RPN cases, and bulldog clamps were used in 979 (91.2 %) cases. The use of a Satinsky clamp was associated with greater operative time (198 vs. 175 min, p clamp group, but none were directly related to the Satinsky clamp. On multivariable analysis, the use of the Satinsky clamp was not associated with increase in intraoperative or Clavien ≥3 postoperative complications, positive surgical margin rate or percentage change in estimated glomerular filtration rate. A Satinsky clamp can be a backup option for hilar clamping during challenging RPN cases, but requires careful technique, and was rarely necessary.

  5. The GlueX Start Counter and Beam Asymmetry$\\Sigma$ in Single $\\pi^{0}$ Photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Pooser, Eric [Florida Intl Univ., Miami, FL (United States)

    2016-03-26

    The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 108 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\\vec{p}$→ π0p, where π0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

  6. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  7. Seabed habitat mapping employing single and multi-beam backscatter data: A case study from the western continental shelf of India

    Digital Repository Service at National Institute of Oceanography (India)

    Haris, K.; Chakraborty, B.; Ingole, B.S.; Menezes, A.A.A.; Srivastava, R.

    Acoustic backscatter from multi-beam echo-sounder (MBES) and dual-frequency single-beam echo-sounding systems (SBES) operable at 95 kHz and 33/210 kHz, respectively, were used to study the distribution of sediment texture and benthic macro...

  8. Lucretia A Matlab-Based Toolbox for the Modeling and Simulation of Single-Pass Electron Beam Transport Systems

    CERN Document Server

    Tenenbaum, P G

    2005-01-01

    We report on Lucretia, a new simulation tool for the study of single-pass electron beam transport systems. Lucretia supports a combination of analytic and tracking techniques to model the tuning and operation of bunch compressors, linear accelerators, and beam delivery systems of linear colliders and linac-driven Free Electron Laser (FEL) facilities. Extensive use of Matlab scripting, graphics, and numerical capabilities maximize the flexibility of the system, and emphasis has been placed on representing and preserving the fixed relationships between elements (common girders, power supplies, etc.) which must be respected in the design of tuning algorithms. An overview of the code organization, some simple examples, and plans for future development are discussed.

  9. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H.R.; Pol, Robert A.; Hulsebos, Robin G.; van Det, Rob J.; van der Palen, Jacobus Adrianus Maria; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    Background To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. Methods Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inlay

  10. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H. R.; Pol, Robert A.; Hulsebos, Robin G.; van Det, Rob J.; van der Palen, Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    BACKGROUND: To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. METHODS: Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the

  11. Piezoresistive cantilever force-clamp system

    International Nuclear Information System (INIS)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L.; Goodman, Miriam B.

    2011-01-01

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of μN force and nm up to tens of μm displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  12. Simulating the Effects of Surface Roughness on Reinforced Concrete T Beam Bridge under Single and Multiple Vehicles

    Directory of Open Access Journals (Sweden)

    Rahul Kalyankar

    2016-01-01

    Full Text Available This research focuses on the application of the spatial system of finite element modeling for the vehicle-bridge interaction on reinforced concrete US Girder Bridge in order to obtain the effect of surface roughness. Single vehicle and multiple vehicles on reinforced concrete T beam bridge were studied with variable surface roughness profiles. The effects of six different surface roughness profiles (very good, good, measured, average, poor, and very poor were investigated for vehicle-bridge interaction. The values of the Dynamic Amplification Factor (DAF were obtained for single and multiple vehicles on T Beam Bridge for different surface roughness profiles, along with the distances between the axles of heavy vehicle. It was observed that when the bridge has very good, good, measured, and average surface roughness, the DAF values for the single vehicle over the bridge were observed to be within acceptable limits specified by AASHTO. However, for the bridge with multiple vehicles only very good and measured surface roughness profiles showed a DAF and vehicle axle distances within the acceptable limits. From the current studies, it was observed that the spatial system showed reliable responses for predicting the behavior of the bridge under variable road surface roughness conditions and was reliable in vehicle axle detection, and therefore, it has a potential to be use for realistic simulations.

  13. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  14. Model for a collimated spin-wave beam generated by a single-layer spin torque nanocontact

    Science.gov (United States)

    Hoefer, M. A.; Silva, T. J.; Stiles, M. D.

    2008-04-01

    A model of spin-torque-induced magnetization dynamics based on semiclassical spin diffusion theory for a single-layer nanocontact is presented. The model incorporates effects due to the current-induced Oersted field and predicts the generation of a variety of spatially dependent, coherent, precessional magnetic wave structures. Directionally controllable collimated spin-wave beams, vortex spiral waves, and localized standing waves are found to be excited by the interplay of the Oersted field and the orientation of an applied field. These fields act as a spin-wave “corral” around the nanocontact that controls the propagation of spin waves in certain directions.

  15. Kinetic analysis of PCNA clamp binding and release in the clamp loading reaction catalyzed by Saccharomyces cerevisiae replication factor C.

    Science.gov (United States)

    Marzahn, Melissa R; Hayner, Jaclyn N; Meyer, Jennifer A; Bloom, Linda B

    2015-01-01

    DNA polymerases require a sliding clamp to achieve processive DNA synthesis. The toroidal clamps are loaded onto DNA by clamp loaders, members of the AAA+family of ATPases. These enzymes utilize the energy of ATP binding and hydrolysis to perform a variety of cellular functions. In this study, a clamp loader-clamp binding assay was developed to measure the rates of ATP-dependent clamp binding and ATP-hydrolysis-dependent clamp release for the Saccharomyces cerevisiae clamp loader (RFC) and clamp (PCNA). Pre-steady-state kinetics of PCNA binding showed that although ATP binding to RFC increases affinity for PCNA, ATP binding rates and ATP-dependent conformational changes in RFC are fast relative to PCNA binding rates. Interestingly, RFC binds PCNA faster than the Escherichia coli γ complex clamp loader binds the β-clamp. In the process of loading clamps on DNA, RFC maintains contact with PCNA while PCNA closes, as the observed rate of PCNA closing is faster than the rate of PCNA release, precluding the possibility of an open clamp dissociating from DNA. Rates of clamp closing and release are not dependent on the rate of the DNA binding step and are also slower than reported rates of ATP hydrolysis, showing that these rates reflect unique intramolecular reaction steps in the clamp loading pathway. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Single orientation graphene synthesized on iridium thin films grown by molecular beam epitaxy

    OpenAIRE

    Dangwal Pandey, A.; Krausert, Konstantin; Franz, D.; Grånäs, E.; Shayduk, R.; Müller, P.; Keller, Thomas F.; Noei, H.; Vonk, V.; Stierle, A.

    2016-01-01

    Heteroepitaxial iridium thin films were deposited on (0001) sapphire substrates by means of molecular beam epitaxy, and subsequently, one monolayer of graphene was synthesized by chemical vapor deposition. The influence of the growth parameters on the quality of the Ir films, as well as of graphene, was investigated system atically by means of low energy electron diffraction, x-ray reflectivity, x-ray diffraction, Auger electron spectroscopy, scanning electron microscopy, and atomic force mic...

  17. Plasma jets produced in a single laser beam interaction with a planar target

    Czech Academy of Sciences Publication Activity Database

    Nicolai, Ph.; Tikhonchuk, V.T.; Kasperczuk, A.; Pisarczyk, T.; Borodziuk, S.; Rohlena, Karel; Ullschmied, Jiří

    2006-01-01

    Roč. 13, č. 6 (2006), 062701/1-062701/8 ISSN 1070-664X R&D Projects: GA MŠk(CZ) LC528 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : laser beams * laser s * plasma devices * plasma jets * plasma (ionized gases) Subject RIV: BH - Optics, Masers, Laser s Impact factor: 2.258, year: 2006

  18. Clamping-induced changes of domain morphology in 88%Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3}-12%PbTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Chang, L.-W., E-mail: lchang01@qub.ac.uk; Gregg, J. M., E-mail: m.gregg@qub.ac.uk [Centre for Nanostructured Media, School of Maths and Physics, Queen' s University Belfast, Northern Ireland BT7 1NN (United Kingdom); Nagarajan, V.; Okatan, M. B. [School of Materials Science and Engineering, University of New South Wales, New South Wales 2052 (Australia)

    2014-08-14

    Domain microstructures in single crystal lamellae of 88%Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3}-12%PbTiO{sub 3} (cut from bulk using focused ion beam milling) have been mapped using both piezoresponse force microscopy and transmission electron microscopy. Dramatic changes from mottled microstructures typical of relaxors to larger scale domains typical of ferroelectrics have been noted. Stresses associated with substrate clamping are suspected as the cause for the transition from short- to long-range polar order, akin to effects induced by cation ordering achieved by thermal quenching.

  19. Tuning permanent magnets with adjustable field clamps

    International Nuclear Information System (INIS)

    Schermer, R.I.

    1987-01-01

    The effective length of a permanent-magnet assembly can be varied by adjusting the geometrical parameters of a field clamp. This paper presents measurements on a representative dipole and quadrupole as the field clamp is withdrawn axially or radially. The detailed behavior depends upon the magnet multipolarity and geometry. As a rule-of-thumb, a 3-mm-thick iron plate placed at one end plane of the magnet will shorten the length by one-third of the magnet bore radius

  20. First Measurement of the Beam Normal Single Spin Asymmetry in $Δ$ Resonance Production by $Q_{\\rm weak}$

    Energy Technology Data Exchange (ETDEWEB)

    Nuruzzaman, nfn [Hampton Univ., Hampton, VA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-08-01

    The beam normal single spin asymmetry ($B_{\\rm n}$) is generated in the scattering of transversely polarized electrons from unpolarized nuclei. The asymmetry arises from the interference of the imaginary part of the two-photon exchange with the one-photon exchange amplitude. The $Q_{\\rm weak}$ experiment has made the first measurement of $B_{\\rm n}$ in the production of the $\\Delta$(1232) resonance, using the $Q_{\\rm weak}$ apparatus in Hall-C at the Thomas Jefferson National Accelerator Facility. The final transverse asymmetry, corrected for backgrounds and beam polarization, is $B_{\\rm n}$ = 43 $\\pm$ 16 ppm at beam energy 1.16 GeV at an average scattering angle of about 8.3 degrees, and invariant mass of 1.2 GeV. The measured preliminary $B_{\\rm n}$ agrees with a preliminary theoretical calculation. $B_{\\rm n}$ for the $\\Delta$ is the only known observable that is sensitive to the $\\Delta$ elastic form-factors ($\\gamma$*$\\Delta\\Delta$) in addition to the generally studied transition form-factors ($\\gamma$*N$\\Delta$), but extracting this information will require significant theoretical input.

  1. Clamp loader ATPases and the evolution of DNA replication machinery

    Science.gov (United States)

    2012-01-01

    Clamp loaders are pentameric ATPases of the AAA+ family that operate to ensure processive DNA replication. They do so by loading onto DNA the ring-shaped sliding clamps that tether the polymerase to the DNA. Structural and biochemical analysis of clamp loaders has shown how, despite differences in composition across different branches of life, all clamp loaders undergo the same concerted conformational transformations, which generate a binding surface for the open clamp and an internal spiral chamber into which the DNA at the replication fork can slide, triggering ATP hydrolysis, release of the clamp loader, and closure of the clamp round the DNA. We review here the current understanding of the clamp loader mechanism and discuss the implications of the differences between clamp loaders from the different branches of life. PMID:22520345

  2. MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C

    Science.gov (United States)

    Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.

    2012-01-01

    We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681

  3. A 3% Measurement of the Beam Normal Single Spin Asymmetry in Forward Angle Elastic Electron-Proton Scattering using the Qweak Setup

    Energy Technology Data Exchange (ETDEWEB)

    Waidyawansa, Dinayadura Buddhini [Ohio Univ., Athens, OH (United States)

    2013-08-01

    The beam normal single spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable of the imaginary part of the two-photon exchange process. Moreover, it is a potential source of false asymmetry in parity violating electron scattering experiments. The Q{sub weak} experiment uses parity violating electron scattering to make a direct measurement of the weak charge of the proton. The targeted 4% measurement of the weak charge of the proton probes for parity violating new physics beyond the Standard Model. The beam normal single spin asymmetry at Q{sub weak} kinematics is at least three orders of magnitude larger than 5 ppb precision of the parity violating asymmetry. To better understand this parity conserving background, the Q{sub weak} Collaboration has performed elastic scattering measurements with fully transversely polarized electron beam on the proton and aluminum. This dissertation presents the analysis of the 3% measurement (1.3% statistical and 2.6% systematic) of beam normal single spin asymmetry in electronproton scattering at a Q2 of 0.025 (GeV/c)2. It is the most precise existing measurement of beam normal single spin asymmetry available at the time. A measurement of this precision helps to improve the theoretical models on beam normal single spin asymmetry and thereby our understanding of the doubly virtual Compton scattering process.

  4. Forced Vibrations of a Cantilever Beam

    Science.gov (United States)

    Repetto, C. E.; Roatta, A.; Welti, R. J.

    2012-01-01

    The theoretical and experimental solutions for vibrations of a vertical-oriented, prismatic, thin cantilever beam are studied. The beam orientation is "downwards", i.e. the clamped end is above the free end, and it is subjected to a transverse movement at a selected frequency. Both the behaviour of the device driver and the beam's weak-damping…

  5. GaN Schottky diodes with single-crystal aluminum barriers grown by plasma-assisted molecular beam epitaxy

    Science.gov (United States)

    Tseng, H. Y.; Yang, W. C.; Lee, P. Y.; Lin, C. W.; Cheng, Kai-Yuan; Hsieh, K. C.; Cheng, K. Y.; Hsu, C.-H.

    2016-08-01

    GaN-based Schottky barrier diodes (SBDs) with single-crystal Al barriers grown by plasma-assisted molecular beam epitaxy are fabricated. Examined using in-situ reflection high-energy electron diffractions, ex-situ high-resolution x-ray diffractions, and high-resolution transmission electron microscopy, it is determined that epitaxial Al grows with its [111] axis coincident with the [0001] axis of the GaN substrate without rotation. In fabricated SBDs, a 0.2 V barrier height enhancement and 2 orders of magnitude reduction in leakage current are observed in single crystal Al/GaN SBDs compared to conventional thermal deposited Al/GaN SBDs. The strain induced piezoelectric field is determined to be the major source of the observed device performance enhancements.

  6. GaN Schottky diodes with single-crystal aluminum barriers grown by plasma-assisted molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, H. Y.; Yang, W. C.; Lee, P. Y.; Lin, C. W.; Cheng, Kai-Yuan; Hsieh, K. C.; Cheng, K. Y., E-mail: kycheng@ee.nthu.edu.tw [Department of Electrical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Hsu, C.-H. [Division of Scientific Research, National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan (China)

    2016-08-22

    GaN-based Schottky barrier diodes (SBDs) with single-crystal Al barriers grown by plasma-assisted molecular beam epitaxy are fabricated. Examined using in-situ reflection high-energy electron diffractions, ex-situ high-resolution x-ray diffractions, and high-resolution transmission electron microscopy, it is determined that epitaxial Al grows with its [111] axis coincident with the [0001] axis of the GaN substrate without rotation. In fabricated SBDs, a 0.2 V barrier height enhancement and 2 orders of magnitude reduction in leakage current are observed in single crystal Al/GaN SBDs compared to conventional thermal deposited Al/GaN SBDs. The strain induced piezoelectric field is determined to be the major source of the observed device performance enhancements.

  7. Electrothermally actuated tunable clamped-guided resonant microbeams

    KAUST Repository

    Alcheikh, Nouha

    2017-06-11

    We present simulation and experimental investigation demonstrating active alteration of the resonant and frequency response behavior of resonators by controlling the electrothermal actuation method on their anchors. In-plane clamped-guided arch and straight microbeams resonators are designed and fabricated with V-shaped electrothermal actuators on their anchors. These anchors not only offer various electrothermal actuation options, but also serve as various mechanical stiffness elements that affect the operating resonance frequency of the structures. We have shown that for an arch, the first mode resonance frequency can be increased up to 50% of its initial value. For a straight beam, we have shown that before buckling, the resonance frequency decreases to very low values and after buckling, it increases up to twice of its initial value. These results can be promising for the realization of different wide–range tunable microresonator. The experimental results have been compared to multi-physics finite-element simulations showing good agreement among them.

  8. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  9. Epitaxial growth and new phase of single crystal Dy by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Yang, Kai-Yueh; Homma, Hitoshi; Schuller, I.K.

    1987-09-01

    We have grown two novel epitaxial phases of dysprosium (Dy) on vanadium (V) by molecular beam epitaxy technique. Surface and bulk structures are studied by in-situ reflection high energy electron diffraction (RHEED) and x-ray diffraction techniques. The new hcp phases are ∼4% expanded uniformly in-plane (0001), and ∼9% and ∼4% expanded out of plane along the c-axes for non-interrupted and interrupted deposition case, respectively. We also observed (2 x 2), (3 x 3), and (4 x 4) Dy surface reconstruction patterns and a series of transitions as the Dy film thickness increases. 12 refs., 3 figs

  10. ANALYTICAL BENDING SOLUTION OF ALL CLAMPED ISOTROPIC ...

    African Journals Online (AJOL)

    The analytical bending solution of all clamped rectangular plate on Winkler foundation using characteristic orthogonal polynomials (COPs) was studied. This was achieved by partially integrating the governing differential equation of rectangular plate on elastic foundation four times with respect to its independents x and y ...

  11. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...

  12. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...

  13. Clamp and Gas Nozzle for TIG Welding

    Science.gov (United States)

    Gue, G. B.; Goller, H. L.

    1982-01-01

    Tool that combines clamp with gas nozzle is aid to tungsten/inert-gas (TIG) welding in hard-to-reach spots. Tool holds work to be welded while directing a stream of argon gas at weld joint, providing an oxygen-free environment for tungsten-arc welding.

  14. VELO Module Production - Cable and Clamp Attachment

    CERN Document Server

    Smith, N A

    2007-01-01

    This note describes in detail the procedures used in the fixing of the clamps to hold the cables in position on the pedestal in the final module assembly for the LHCb VELO detector modules. It summarizes the effects on the module of applying the cables.

  15. SU-E-T-344: Dynamic Electron Beam Therapy Using Multiple Apertures in a Single Cut-Out

    International Nuclear Information System (INIS)

    Rodrigues, A; Yin, F; Wu, Q

    2015-01-01

    Purpose: Few leaf electron collimators (FLEC) or electron MLCs (eMLC) are highly desirable for dynamic electron beam therapies as they produce multiple apertures within a single delivery to achieve conformal dose distributions. However, their clinical implementation has been challenging. Alternatively, multiple small apertures in a single cut-out with variable jaw sizes could be utilized in a single dynamic delivery. In this study, we investigate dosimetric characteristics of such arrangement. Methods: Monte Carlo (EGSnrc/BEAMnrc/DOSXYnrc) simulations utilized validated Varian TrueBeam phase spaces. Investigated quantities included: Energy (6 MeV), jaw size (1×1 to 22×22 cm 2 ; centered to aperture), applicator/cut-out (15×15 cm 2 ), aperture (1×1, 2×2, 3×3, 4×4 cm 2 ), and aperture placement (on/off central axis). Three configurations were assessed: (1) single aperture on-axis, (2) single aperture off-axis, and (3) multiple apertures. Reference was configuration (1) with standard jaw size. Aperture placement and jaw size were optimized to maintain reference dosimetry and minimize leakage through unused apertures to <5%. Comparison metrics included depth dose and orthogonal profiles. Results: Configuration (1) and (2): Jaw openings were reduced to 10×10 cm 2 without affecting dosimetry (gamma 2%/1mm) regardless of on- or off-axis placement. For smaller jaw sizes, reduced surface (<2%, 5% for 1×1 cm 2 aperture) and increased Bremsstrahlung (<2%, 10% for 1×1 cm 2 aperture) dose was observed. Configuration (3): Optimal aperture placement was in the corners (order: 1×1, 4×4, 2×2, 3×3 cm 2 ) and jaw sizes were 4×4, 4×4, 7×7, and 5×5 cm 2 (apertures: 1×1, 2×2, 3×3, 4×4 cm 2 ). Asymmetric leakage was found from upper and lower jaws. Leakage was generally within 5% with a maximum of 10% observed for the 1×1 cm 2 aperture irradiation. Conclusion: Multiple apertures in a single cut-out with variable jaw size can be used in a single dynamic delivery

  16. Optimal piezoelectric beam shape for single and broadband vibration energy harvesting: Modeling, simulation and experimental results

    Science.gov (United States)

    Muthalif, Asan G. A.; Nordin, N. H. Diyana

    2015-03-01

    Harvesting energy from the surroundings has become a new trend in saving our environment. Among the established ones are solar panels, wind turbines and hydroelectric generators which have successfully grown in meeting the world's energy demand. However, for low powered electronic devices; especially when being placed in a remote area, micro scale energy harvesting is preferable. One of the popular methods is via vibration energy scavenging which converts mechanical energy (from vibration) to electrical energy by the effect of coupling between mechanical variables and electric or magnetic fields. As the voltage generated greatly depends on the geometry and size of the piezoelectric material, there is a need to define an optimum shape and configuration of the piezoelectric energy scavenger. In this research, mathematical derivations for unimorph piezoelectric energy harvester are presented. Simulation is done using MATLAB and COMSOL Multiphysics software to study the effect of varying the length and shape of the beam to the generated voltage. Experimental results comparing triangular and rectangular shaped piezoelectric beam are also presented.

  17. On the Nonlinear Dynamics of a Doubly Clamped Microbeam near Primary Resonance

    KAUST Repository

    Jaber, Nizar

    2017-04-07

    This work aims to investigate theoretically and experimentally various nonlinear dynamic behaviors of a doubly clamped microbeam near its primary resonance. Mainly, we investigate the transition behavior from hardening, mixed, and then softening behavior. We show in a single frequency-response curve, under a constant voltage load, the transition from hardening to softening behavior demonstrating the dominance of the quadratic electrostatic nonlinearity over the cubic geometric nonlinearity of the beam as the motion amplitudes becomes large, which may lead eventually to dynamic pull-in. The microbeam is fabricated using polyimide as a structural layer coated with nickel from top and chromium and gold layers from the bottom. Frequency sweep tests are conducted for different values of DC bias revealing hardening, mixed, and softening behavior of the microbeam. A multi-mode Galerkin model combined with a shooting technique are implemented to generate the frequency response curves and to analyze the stability of the periodic motions using the Floquet theory. The simulated curves show good agreement with the experimental data.

  18. Cerebral haemodynamics during carotid cross-clamping.

    Science.gov (United States)

    Pistolese, G R; Ippoliti, A; Appolloni, A; Ronchey, S; Faraglia, V

    1993-03-01

    Carotid artery cross-clamping ischaemia during carotid endarterectomy (CEA) causes 5-30% of perioperative neurological deficits. This study was performed to identify possible clinical situations at higher risk for carotid cross-clamping ischaemia. 606 consecutive patients underwent CEA and were retrospectively studied; they were grouped according to risk factors, presence of associated vascular diseases, clinical pattern, angiographic and CT scan findings. Stump pressure measurement was provided in all patients, perioperative monitoring during CEA was performed by electroencephalogram (EEG) in 469 (77%) and somatosensorial evoked potentials (SEP) in 137 (23%). Local anaesthesia was used in 88 (14.5%) patients. Ischaemic changes during carotid cross-clamping were registered in 118 patients (19.5%). The incidence of cross-clamping ischaemia was then related to different factors; it affected 5.6% of asymptomatics, 25.4% of patients with fixed stroke and 38.5% of those with stenosis and contralateral occlusion. Angiographic and clinical correlation showed that patients with more severe lesions are mostly affected by clamping ischaemia (up to 55% in those with stroke and stenosis with contralateral occlusion). Age, hypertension and diabetes do not significantly affect incidence of ischaemic changes. Positive CT scan increased this risk; statistical relevance was found in regard to patients with unilateral or bilateral stenosis and in those with transient ischaemic attacks. A higher risk can be expected for subjects with more severe clinical and instrumental findings, even if no patients can be considered completely at risk or risk free. Perioperative monitoring is always mandatory and is of great importance in detecting ischaemic changes and preventing cerebral damage using a temporary intraluminal shunt.

  19. Single-bunch beam breakup in a dielectric-lined waveguide

    International Nuclear Information System (INIS)

    Ng, King-Yuen.

    1992-08-01

    We examine beam breakup of a 100 nC I mm-long (rms) source bunch inside a cylindrical dielectric waveguide, with dielectric ε = 2.65 filling the radius between 7.5 and 9.0 mm. Only ∼ 78% of the bunch with an initial offset of 0.3 mm survives the passage of the 3.75 m waveguide. The loss is mainly due to the large deflections of some particles that are slowed down to nearly zero velocity. As a result, quadrupole focussing of any sort will not help. However, if the waveguide is shortened to 3.3 m, the loss reduces to only 5.5%

  20. Microwave electromechanical resonator consisting of clamped carbon nanotubes in an abacus arrangement

    Science.gov (United States)

    Peng, H. B.; Chang, C. W.; Aloni, S.; Yuzvinsky, T. D.; Zettl, A.

    2007-07-01

    We describe nanoscale electromechanical resonators capable of operating in ambient-pressure air at room temperature with unprecedented fundamental resonance frequency of ˜4GHz . The devices are created from suspended carbon nanotubes loaded abacus style with inertial metal clamps, yielding short effective beam lengths. We examine the energy dissipation in the system due to air damping and contact loss. Such nanoabacus resonators open windows for immediate practical microwave frequency nanoelectromechanical system applications.

  1. Pipe clamp effects on thin-walled pipe design

    International Nuclear Information System (INIS)

    Lindquist, M.R.

    1980-01-01

    Clamp induced stresses in FFTF piping are sufficiently large to require structural assessment. The basic principles and procedures used in analyzing FFTF piping at clamp support locations for compliance with ASME Code rules are given. Typical results from a three-dimensional shell finite element pipe model with clamp loads applied over the clamp/pipe contact area are shown. Analyses performed to categorize clamp induced piping loads as primary or secondary in nature are described. The ELCLAMP Computer Code, which performs analyses at clamp locations combining clamp induced stresses with stresses from overall piping system loads, is discussed. Grouping and enveloping methods to reduce the number of individual clamp locations requiring analysis are described

  2. Ion beam induced single phase nanocrystalline TiO2 formation

    Science.gov (United States)

    Rukade, Deepti A.; Tribedi, L. C.; Bhattacharyya, Varsha

    2014-06-01

    Single phase TiO2 nanostructures are fabricated by oxygen ion implantation (60 keV) at fluence ranging from 1×1016 ions/cm2 to 1×1017 ions/cm2 in titanium thin films deposited on fused silica substrate and subsequent thermal annealing in argon atmosphere. GAXRD and Raman spectroscopy study reveals formation of single rutile phases of TiO2. Particle size is found to vary from 29 nm to 35 nm, establishing nanostructure formation. Nanostructure formation is also confirmed by the quantum confinement effect manifested by the blueshift of the UV-vis absorption spectra. Photoluminescence spectra show peaks corresponding to TiO2 rutile phase and reveal the presence of oxygen defects due to implantation. The controlled synthesis of single phase nanostructure is attributed to ion induced defects and post-implantation annealing. It is observed that the size of the nanostructures formed is strongly dependent on the ion fluence.

  3. Shear and foundation effects on crack root rotation and mode-mixity in moment- and force-loaded single cantilever beam sandwich specimen

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Carlsson, Leif A.; Berggreen, Christian

    2017-01-01

    Foundation effects play a crucial role in sandwich fracture specimens with a soft core. Accurate estimation of deformationcharacteristics at the crack front is vital in understanding compliance, energy release rate and mode-mixity infracture test specimens. Beam on elastic foundation analysis...... beam specimen (in contrast to themoment-loaded case), it was found that the crack length normalized energy release rate and the mode-mixity phaseangle increase strongly as the crack length decreases, a result of increased dominance of shear loading....... of moment- and force-loaded single cantilever beam sandwichfracture specimens is presented here. In addition, finite element analysis of the single cantilever beam specimen isconducted to determine displacements, rotations, energy release rate and mode-mixity. Based on finite element analysis,a foundation...

  4. Mechanical and metallurgical properties of carotid artery clamps.

    Science.gov (United States)

    Dujovny, M; Kossovsky, N; Kossowsky, R; Segal, R; Diaz, F G; Kaufman, H; Perlin, A; Cook, E E

    1985-11-01

    The mechanical and metallurgical properties of carotid artery clamps were evaluated. The pressure plate retreat propensity, metallurgical composition, surface morphology, magnetic properties, and corrosion resistance of the Crutchfield, Selverstone, Salibi, and Kindt clamps were tested. None of the clamps showed evidence of pressure plate retreat. The clamps differed significantly in their composition, surface cleanliness, magnetic properties, and corrosion resistance. The Crutchfield clamp was the only one manufactured from an ASTM-ANSI-approved implantable stainless steel (AISI 316) and the only clamp in which the surfaces were clean and free of debris. The Selverstone clamp was made principally from AISI 304 stainless steel, as was one Salibi clamp. The pressure plate on another Salibi clamp was made from a 1% chromium and 1% manganese steel. Machining and surface debris consisting principally of aluminum, silicon, and sulfur was abundant on the Selverstone and Salibi clamps. The Kindt clamp was manufactured from AISI 301 stainless steel with a silicate-aluminized outer coating. The Crutchfield and Selverstone clamps were essentially nonferromagnetic, whereas the Salibi and Kindt clamps were sensitive to magnetic flux. In the pitting potential corrosion test, the Crutchfield clamp demonstrated good corrosion resistance with a pitting potential of 310 mV and no surface corrosion or pitting by scanning electron microscopy examination. The Selverstone clamp had lower pitting potentials and showed various degrees of corrosion and surface pitting by scanning electron microscopy. The Salibi pressure plate had a very low pitting potential of -525 mV and showed severe corrosion. By metallurgical criteria, only the Crutchfield clamp is suitable for long term implantation.

  5. The online chemical analysis of single particles using aerosol beams and time of flight mass spectroscopy

    NARCIS (Netherlands)

    Kievit, O.; Weiss, M.; Verheijen, P.J.T.; Marijnissen, J.C.M.; Scarlett, B.

    This paper describes an on-line instrument, capable of measuring the size and chemical composition of single aerosol particles. Possible applications include monitoring aerosol reactors and studying atmospheric chemistry. The main conclusion is that a working prototype has been built and tested. It

  6. Electromagnetic fields created by a beam in an axisymmetric infinitely thick single-layer resistive pipe: general formulas and low frequency approximations

    CERN Document Server

    Mounet, Nicolas Frank; CERN. Geneva. ATS Department

    2015-01-01

    This note provides general and approximate formulas for the electromagnetic fields created by a passing beam in an axisymmetric infinitely thick resistive pipe made of a single homogeneous layer. The full derivations and their resulting approximate expressions at low and intermediate frequencies are given here, as well as the conditions under which those approximations are valid. Beam-coupling impedances are also computed, and examples are shown.

  7. Analysis of the Pallet Clamping Conditions in Work Positioning

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2016-01-01

    Full Text Available Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and defines the conditions to ensure the trouble-free clamping lock. The circular and rhombic clamping of pallet is simultaneous. Further, a clamping load is calculated from the pallet mass (together with the work-piece and the geometric parameters of the pallet clamping.The paper reveals three movement stages of the clamping lock in a vertical plane when setting the pallet in work positioning:- a clamping lock free play till it encounters with the location bushing;- a clamping lock play length when the lead-in chamfer contacts the bushing chamfer;- a clamping lock play length over the circular surface of bushing.The study of this process has allowed us to calculate the time of pallet clamping and dynamic loads acting on the clamping lock. These calculations made it possible to calculate the required diameter of the clamping lock. The presented calculations allow a reasonable assigning the main design parameters of work positioning for the pallet automatic lines.

  8. 21 CFR 876.5160 - Urological clamp for males.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urological clamp for males. 876.5160 Section 876...) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5160 Urological clamp for males. (a) Identification. A urological clamp for males is a device used to close the urethra of a male to...

  9. 21 CFR 882.5175 - Carotid artery clamp.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Carotid artery clamp. 882.5175 Section 882.5175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5175 Carotid artery clamp. (a) Identification. A carotid artery clamp is a device that is surgically placed around a patient's carotid artery...

  10. Propagation of Single-Mode Fibre Laser Beams through an Optical ABCD System with Circular Aperture at the Fibre Output End

    International Nuclear Information System (INIS)

    Kai-Liang, Duan; Jian-Feng, Li; Wei, Zhao; Yi-Shan, Wang

    2008-01-01

    Based on the expansion expression of the fundamental mode of a single-mode fibre in terms of Laguerre–Gauss modes, the propagation of a beam of a weakly guiding fibre laser through an optical ABCD system with a circular aperture at the fibre end is studied. The results show that there is much difference between the propagation of the laser beam described by the expansion expression and by the Gaussian mode approximation. The depth of focus of the laser beam is longer than that of the Gaussian modes

  11. Towards ion beam synthesis of single CdSe nanocrystal quantum dots in a SiO{sub 2} matrix

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Hans Moritz; Kinzel, Joerg B.; Krenner, Hubert J. [Emmy Noether Group at Lehrstuhl Experimentalphysik 1, Universitaet Augsburg (Germany); Karl, Helmut [Lehrstuhl Experimentalphysik IV, Universitaet Augsburg (Germany); Wixforth, Achim [Lehrstuhl Experimentalphysik I, Universitaet Augsburg (Germany)

    2013-07-01

    II-VI compound semiconductor quantum dots (QDs) are a promising class of materials for applications in optical devices in the visible spectral domain. Here we show that in addition to traditional fabrication techniques such as molecular beam epitaxy or chemical synthesis, high fluence ion-beam implantation followed by a rapid thermal annealing step, can be readily applied to synthesize CdSe nanocrystals with superior optical properties within the thermal oxide on a Si wafer. In order to confine the implantation volume we employ chromium masks with arrays of nanoscale aperture openings with diameters smaller than 250 nm. We analyzed the such implanted and annealed samples by scanning electron microscopy and micro-photoluminescence spectroscopy. We observe a pronounced broadening and blue shift of the nanocrystal emission when decreasing the aperture diameter to <1000 nm. We attribute this behavior to a reduction of the mean nanocrystal size but increase of its size distribution. For the smallest aperture sizes used we observe a pronounced shell-filling behavior characteristic for single quantum dot nanoemitters.

  12. Focused-ion-beam overlay-patterning of three-dimensional diamond structures for advanced single-photon properties

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Qianqing; Liu, Dongqi; Liu, Gangqin; Chang, Yanchun; Li, Wuxia, E-mail: liwuxia@aphy.iphy.ac.cn, E-mail: czgu@aphy.iphy.ac.cn [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Pan, Xinyu; Gu, Changzhi, E-mail: liwuxia@aphy.iphy.ac.cn, E-mail: czgu@aphy.iphy.ac.cn [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Collaborative Innovation Center of Quantum Matter, Beijing 100190 (China)

    2014-07-28

    Sources of single photons are of fundamental importance in many applications as to provide quantum states for quantum communication and quantum information processing. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, even at room temperature. However, the efficiency of photon collection of the color centers in bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, diamond structuring has been investigated by various methods. Among them, focused-ion-beam (FIB) direct patterning has been recognized as the most favorable technique. But it has been noted that diamond tends to present significant challenges in FIB milling, e.g., the susceptibility of forming charging related artifacts and topographical features. In this work, periodically-positioned-rings and overlay patterning with stagger-superimposed-rings were proposed to alleviate some problems encountered in FIB milling of diamond, for improved surface morphology and shape control. Cross-scale network and uniform nanostructure arrays have been achieved in single crystalline diamond substrates. High quality diamond solid immersion lens and nanopillars were sculptured with a nitrogen-vacancy center buried at the desired position. Compared with the film counterpart, an enhancement of about ten folds in single photon collection efficiency was achieved with greatly improved signal to noise ratio. All these results indicate that FIB milling through over-lay patterning could be an effective approach to fabricate diamond structures, potentially for quantum information studies.

  13. Computational Model of Rabbit SA Node Pacemaker Activity Probed with Action Potential and Calcium Transient Clamp

    NARCIS (Netherlands)

    van Borren, Marcel M. J.; Zegers, Jan G.; Verkerk, Arie O.; Wilders, Ronald

    2007-01-01

    In the past decades, various computational models of the pacemaker activity of single sinoatrial (SA) nodal cells have been developed, building on data obtained in patch-clamp experiments on isolated SA nodal myocytes. These models show widely different results regarding the contribution of

  14. Analysis of using protons in secondary beam on BEPC as a particle source in single event effects experiment study

    International Nuclear Information System (INIS)

    He Chaohui; Li Guozheng; Liu Enke

    1999-01-01

    The energy range and yield of the protons in the secondary beam on BEPC are first analyzed, at the point of using the protons as a particle source in the single event effects (SEE) experiment of semiconductor devices. The energy ranges of the proton produced by high energy electrons bombarding on targets in three methods are calculated and the corresponding cross sections are estimated. The cross section of producing protons can be increased by using heavy nucleus target and the differential yield of protons can reach 1.66 x 10 -3 s -1 ·sr -1 ·eV -1 . The protons can be used in SEE experiment of the semiconductor devices with the high SEE cross sections

  15. Imperfection Sensitivity of Nonlinear Vibration of Curved Single-Walled Carbon Nanotubes Based on Nonlocal Timoshenko Beam Theory

    Directory of Open Access Journals (Sweden)

    Iman Eshraghi

    2016-09-01

    Full Text Available Imperfection sensitivity of large amplitude vibration of curved single-walled carbon nanotubes (SWCNTs is considered in this study. The SWCNT is modeled as a Timoshenko nano-beam and its curved shape is included as an initial geometric imperfection term in the displacement field. Geometric nonlinearities of von Kármán type and nonlocal elasticity theory of Eringen are employed to derive governing equations of motion. Spatial discretization of governing equations and associated boundary conditions is performed using differential quadrature (DQ method and the corresponding nonlinear eigenvalue problem is iteratively solved. Effects of amplitude and location of the geometric imperfection, and the nonlocal small-scale parameter on the nonlinear frequency for various boundary conditions are investigated. The results show that the geometric imperfection and non-locality play a significant role in the nonlinear vibration characteristics of curved SWCNTs.

  16. Single orientation graphene synthesized on iridium thin films grown by molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Dangwal Pandey, A., E-mail: arti.pandey@desy.de; Grånäs, E.; Shayduk, R.; Noei, H.; Vonk, V. [Deutsches Elektronen-Synchrotron (DESY), D-22607 Hamburg (Germany); Krausert, K.; Franz, D.; Müller, P.; Keller, T. F.; Stierle, A., E-mail: andreas.stierle@desy.de [Deutsches Elektronen-Synchrotron (DESY), D-22607 Hamburg (Germany); Fachbereich Physik, Universität Hamburg, D-22607 Hamburg (Germany)

    2016-08-21

    Heteroepitaxial iridium thin films were deposited on (0001) sapphire substrates by means of molecular beam epitaxy, and subsequently, one monolayer of graphene was synthesized by chemical vapor deposition. The influence of the growth parameters on the quality of the Ir films, as well as of graphene, was investigated systematically by means of low energy electron diffraction, x-ray reflectivity, x-ray diffraction, Auger electron spectroscopy, scanning electron microscopy, and atomic force microscopy. Our study reveals (111) oriented iridium films with high crystalline quality and extremely low surface roughness, on which the formation of large-area epitaxial graphene is achieved. The presence of defects, like dislocations, twins, and 30° rotated domains in the iridium films is also discussed. The coverage of graphene was found to be influenced by the presence of 30° rotated domains in the Ir films. Low iridium deposition rates suppress these rotated domains and an almost complete coverage of graphene was obtained. This synthesis route yields inexpensive, air-stable, and large-area graphene with a well-defined orientation, making it accessible to a wider community of researchers for numerous experiments or applications, including those which use destructive analysis techniques or irreversible processes. Moreover, this approach can be used to tune the structural quality of graphene, allowing a systematic study of the influence of defects in various processes like intercalation below graphene.

  17. Polarization-dependent single-beam laser-induced grating-like effects on titanium films

    International Nuclear Information System (INIS)

    Camacho-Lopez, Santiago; Evans, Rodger; Escobar-Alarcon, Luis; Camacho-Lopez, Miguel A.; Camacho-Lopez, Marco A.

    2008-01-01

    In this paper we present results on polarization-dependent laser-induced effects on titanium (Ti) thin films. We irradiated the titanium films, in ambient air, using a nanosecond Nd:YAG laser (532 nm, 9 ns pulse duration, 10 Hz). Using a series of pulses of fluence well below the ablation threshold, it was possible to form grating-like structures, whose grooves run parallel to the linear polarization of the incident beam. No grating-like structures were obtained when circularly polarized light was used. Our results revealed the remarkable formation of tiny (100 nm and even smaller diameter) craters, which self-arrange quasi-periodically along the ridges (never on the valleys) of the grating-like structure. Optical and scanning electron microscopy were used to study the laser-induced changes on the surface of the titanium films. Micro-Raman spectroscopy was used to analyze the irradiated areas on the titanium films. The Raman analysis demonstrated that the grooves in the grating-like structure, build up from the laser-induced oxidation of titanium. This is the first time, to the best of our knowledge, that periodic surface structures are reported to be induced below the ablation threshold regime, with the grooves made of crystalline metal oxide, in this case TiO 2 in the well-known Rutile phase. The laser irradiated areas on the film acquired selective (upon recording polarization) holographic reflectance

  18. Single source sound production and dynamic beam formation in echolocating harbour porpoises (Phocoena phocoena)

    DEFF Research Database (Denmark)

    Madsen, Peter Teglberg; Wisniewska, Danuta Maria; Beedholm, Kristian

    2010-01-01

    Echolocating toothed whales produce high-powered clicks by pneumatic actuation of phonic lips in their nasal complexes. All non-physeteroid toothed whales have two pairs of phonic lips allowing many of these species to produce both whistles and clicks at the same time. That has led to the hypothe......Echolocating toothed whales produce high-powered clicks by pneumatic actuation of phonic lips in their nasal complexes. All non-physeteroid toothed whales have two pairs of phonic lips allowing many of these species to produce both whistles and clicks at the same time. That has led...... of three echolocating porpoises (Phocoena phocoena) with symmetrical pairs of phonic lips. Using time of arrival differences on three hydrophones, we show that all recorded clicks from these three porpoises are produced by the right pair of phonic lips with no evidence of simultaneous or independent...... as a waveguide for sound energy between 100 and 160 kHz to generate a forward-directed sound beam for echolocation....

  19. Polarization-dependent single-beam laser-induced grating-like effects on titanium films

    Energy Technology Data Exchange (ETDEWEB)

    Camacho-Lopez, Santiago [Departamento de Optica, Centro de Investigacion Cientifica y de Educacion Superior de Ensenada, Km 107 Carretera Tijuana-Ensenada, Ensenada, Baja California 22860 (Mexico)], E-mail: camachol@cicese.mx; Evans, Rodger [Departamento de Optica, Centro de Investigacion Cientifica y de Educacion Superior de Ensenada, Km 107 Carretera Tijuana-Ensenada, Ensenada, Baja California 22860 (Mexico); Escobar-Alarcon, Luis [Departamento de Fisica, Instituto Nacional de Investigaciones Nucleares, Apdo. Postal 18-1027, Mexico DF 11801 (Mexico); Camacho-Lopez, Miguel A. [Facultad de Medicina, Universidad Autonoma del Estado de Mexico, Paseo Tollocan s/n, esq. Jesus Carranza, Toluca, Estado de Mexico 50120 (Mexico); Camacho-Lopez, Marco A. [Facultad de Quimica, Universidad Autonoma del Estado de Mexico, Tollocan s/n, esq. Paseo Colon, Toluca, Estado de Mexico, 50110 (Mexico)

    2008-12-30

    In this paper we present results on polarization-dependent laser-induced effects on titanium (Ti) thin films. We irradiated the titanium films, in ambient air, using a nanosecond Nd:YAG laser (532 nm, 9 ns pulse duration, 10 Hz). Using a series of pulses of fluence well below the ablation threshold, it was possible to form grating-like structures, whose grooves run parallel to the linear polarization of the incident beam. No grating-like structures were obtained when circularly polarized light was used. Our results revealed the remarkable formation of tiny (100 nm and even smaller diameter) craters, which self-arrange quasi-periodically along the ridges (never on the valleys) of the grating-like structure. Optical and scanning electron microscopy were used to study the laser-induced changes on the surface of the titanium films. Micro-Raman spectroscopy was used to analyze the irradiated areas on the titanium films. The Raman analysis demonstrated that the grooves in the grating-like structure, build up from the laser-induced oxidation of titanium. This is the first time, to the best of our knowledge, that periodic surface structures are reported to be induced below the ablation threshold regime, with the grooves made of crystalline metal oxide, in this case TiO{sub 2} in the well-known Rutile phase. The laser irradiated areas on the film acquired selective (upon recording polarization) holographic reflectance.

  20. High-speed dynamic-clamp interface

    Science.gov (United States)

    Yang, Yang; Adowski, Timothy; Ramamurthy, Bina; Neef, Andreas

    2015-01-01

    The dynamic-clamp technique is highly useful for mimicking synaptic or voltage-gated conductances. However, its use remains rare in part because there are few systems, and they can be expensive and difficult for less-experienced programmers to implement. Furthermore, some conductances (such as sodium channels) can be quite rapid or may have complex voltage sensitivity, so high speeds are necessary. To address these issues, we have developed a new interface that uses a common personal computer platform with National Instruments data acquisition and WaveMetrics IGOR to provide a simple user interface. This dynamic clamp implements leak and linear synaptic conductances as well as a voltage-dependent synaptic conductance and kinetic channel conductances based on Hodgkin-Huxley or Markov models. The speed of the system can be assayed using a testing mode, and currently speeds of >100 kHz (10 μs per cycle) are achievable with short latency and little jitter. PMID:25632075

  1. Ion beam induced single phase nanocrystalline TiO{sub 2} formation

    Energy Technology Data Exchange (ETDEWEB)

    Rukade, Deepti A. [Department of Physics, University of Mumbai, Mumbai 400098 (India); Tribedi, L.C. [Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Bhattacharyya, Varsha, E-mail: varsha.b1.physics@gmail.com [Department of Physics, University of Mumbai, Mumbai 400098 (India)

    2014-06-15

    Single phase TiO{sub 2} nanostructures are fabricated by oxygen ion implantation (60 keV) at fluence ranging from 1×10{sup 16} ions/cm{sup 2} to 1×10{sup 17} ions/cm{sup 2} in titanium thin films deposited on fused silica substrate and subsequent thermal annealing in argon atmosphere. GAXRD and Raman spectroscopy study reveals formation of single rutile phases of TiO{sub 2}. Particle size is found to vary from 29 nm to 35 nm, establishing nanostructure formation. Nanostructure formation is also confirmed by the quantum confinement effect manifested by the blueshift of the UV–vis absorption spectra. Photoluminescence spectra show peaks corresponding to TiO{sub 2} rutile phase and reveal the presence of oxygen defects due to implantation. The controlled synthesis of single phase nanostructure is attributed to ion induced defects and post-implantation annealing. It is observed that the size of the nanostructures formed is strongly dependent on the ion fluence.

  2. Demonstration of a single-crystal reflector-filter for enhancing slow neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Muhrer, G. [European Spallation Source, Lund (Sweden); Los Alamos Neutron Science Center, Los Alamos National Laboratory, Los Alamos, NM (United States); Schönfeldt, T. [Center for Nuclear Technologies, Technical University of Denmark, Roskilde (Denmark); European Spallation Source, Lund (Sweden); Iverson, E.B., E-mail: iversoneb@ornl.gov [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Mocko, M. [Los Alamos Neutron Science Center, Los Alamos National Laboratory, Los Alamos, NM (United States); Baxter, D.V. [Center for the Exploration of Energy and Matter, Indiana University, Bloomington, IN (United States); Hügle, Th.; Gallmeier, F.X. [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Klinkby, E.B. [Center for Nuclear Technologies, Technical University of Denmark, Roskilde (Denmark); European Spallation Source, Lund (Sweden)

    2016-09-11

    The cold polycrystalline beryllium reflector-filter concept has been used to enhance the cold neutron emission of cryogenic hydrogen moderators, while suppressing the intermediate wavelength and fast neutron emission at the same time. While suppressing the fast neutron emission is often desired, the suppression of intermediate wavelength neutrons is often unwelcome. It has been hypothesized that replacing the polycrystalline reflector-filter concept with a single-crystal reflector-filter concept would overcome the suppression of intermediate wavelength neutrons and thereby extend the usability of the reflector-filter concept to shorter but still important wavelengths. In this paper we present the first experimental data on a single-crystal reflector-filter at a reflected neutron source and compare experimental results with hypothesized performance. We find that a single-crystal reflector-filter retains the long-wavelength benefit of the polycrystalline reflector-filter, without suffering the same loss of important intermediate wavelength neutrons. This finding extends the applicability of the reflector-filter concept to intermediate wavelengths, and furthermore indicates that the reflector-filter benefits arise from its interaction with fast (background) neutrons, not with intermediate wavelength neutrons of potential interest in many types of neutron scattering.

  3. Quadratic sinusoidal analysis of voltage clamped neurons.

    Science.gov (United States)

    Magnani, Christophe; Moore, Lee E

    2011-11-01

    Nonlinear biophysical properties of individual neurons are known to play a major role in the nervous system, especially those active at subthreshold membrane potentials that integrate synaptic inputs during action potential initiation. Previous electrophysiological studies have made use of a piecewise linear characterization of voltage clamped neurons, which consists of a sequence of linear admittances computed at different voltage levels. In this paper, a fundamentally new theory is developed in two stages. First, analytical equations are derived for a multi-sinusoidal voltage clamp of a Hodgkin-Huxley type model to reveal the quadratic response at the ionic channel level. Second, the resulting behavior is generalized to a novel Hermitian neural operator, which uses an algebraic formulation capturing the entire quadratic behavior of a voltage clamped neuron. In addition, this operator can also be used for a nonlinear identification analysis directly applicable to experimental measurements. In this case, a Hermitian matrix of interactions is built with paired frequency probing measurements performed at specific harmonic and interactive output frequencies. More importantly, eigenanalysis of the neural operator provides a concise signature of the voltage dependent conductances determined by their particular distribution on the dendritic and somatic membrane regions of neurons. Finally, the theory is concretely illustrated by an analysis of an experimentally measured vestibular neuron, providing a remarkably compact description of the quadratic responses involved in the nonlinear processing underlying the control of eye position during head rotation, namely the neural integrator.

  4. A Dynamic Clamp on Every Rig.

    Science.gov (United States)

    Desai, Niraj S; Gray, Richard; Johnston, Daniel

    2017-01-01

    The dynamic clamp should be a standard part of every cellular electrophysiologist's toolbox. That it is not, even 25 years after its introduction, comes down to three issues: money, the disruption that adding dynamic clamp to an existing electrophysiology rig entails, and the technical prowess required of experimenters. These have been valid and limiting issues in the past, but no longer. Technological advances associated with the so-called maker movement render them moot. We demonstrate this by implementing a fast (∼100 kHz) dynamic clamp system using an inexpensive microcontroller (Teensy 3.6). The overall cost of the system is less than USD$100, and assembling it requires no prior electronics experience. Modifying it-for example, to add Hodgkin-Huxley-style conductances-requires no prior programming experience. The system works together with existing electrophysiology data acquisition systems (for Macintosh, Windows, and Linux); it does not attempt to supplant them. Moreover, the process of assembling, modifying, and using the system constitutes a useful pedagogical exercise for students and researchers with no background but an interest in electronics and programming. We demonstrate the system's utility by implementing conductances as fast as a transient sodium conductance and as complex as the Ornstein-Uhlenbeck conductances of the "point conductance" model of synaptic background activity.

  5. Application of Automated Image-guided Patch Clamp for the Study of Neurons in Brain Slices.

    Science.gov (United States)

    Wu, Qiuyu; Chubykin, Alexander A

    2017-07-31

    Whole-cell patch clamp is the gold-standard method to measure the electrical properties of single cells. However, the in vitro patch clamp remains a challenging and low-throughput technique due to its complexity and high reliance on user operation and control. This manuscript demonstrates an image-guided automatic patch clamp system for in vitro whole-cell patch clamp experiments in acute brain slices. Our system implements a computer vision-based algorithm to detect fluorescently labeled cells and to target them for fully automatic patching using a micromanipulator and internal pipette pressure control. The entire process is highly automated, with minimal requirements for human intervention. Real-time experimental information, including electrical resistance and internal pipette pressure, are documented electronically for future analysis and for optimization to different cell types. Although our system is described in the context of acute brain slice recordings, it can also be applied to the automated image-guided patch clamp of dissociated neurons, organotypic slice cultures, and other non-neuronal cell types.

  6. A simple technique to measure regional cerebral blood flow during intravascular ballon clamping

    International Nuclear Information System (INIS)

    Furuhata, Shigeru; Kubo, Atsushi; Kawase, Takeshi; Ibata, Yukio; Toya, Shigeo

    1988-01-01

    A case of giant internal carotid ophthalmic aneurysm was presented. In order to clarify whether the patient could tolerate carotid occlusion, a ballon clamping test was performed before surgery. The cerebral blood flow was measured using early imaging by single photon emission computed tomography (SPECT) with N-isopropyl-(iodine-123)-p-iodoamphetamine ( 123 I-IMP). When the ballon clamping test was performed the tracer was injected, and scanning was performed 35 minutes after removing the catheter. This tracer enabled a 'memory of blood flow' during temporary ischemia to determine the character of quick diffusion and slow wash out, that could not be performed by other methods of cerebral blood flow measurement. SPECT with 123 I-IMP can simplify the measurement of cerebral blood flow during the balloon clamping test. (author)

  7. Relativistic electron beams driven by single-cycle laser pulses at kHz repetition rate (Conference Presentation)

    Science.gov (United States)

    Faure, Jérôme; Guénot, Diego; Gustas, Dominykas; Vernier, Aline; Beaurepaire, Benoît; Böhle, Frederik; López-Martens, Rodrigo; Lifschitz, Agustin

    2017-05-01

    Laser-plasma accelerators are usually driven by 100-TW class laser systems with rather low repetition rates. However, recent years have seen the emergence of laser-plasma accelerators operating with kHz lasers and energies lower than 10 mJ. The high repetition-rate is particularly interesting for applications requiring high stability and high signal-to-noise ratio but lower energy electrons. For example, our group recently demonstrated that kHz laser-driven electron beams could be used to capture ultrafast structural dynamics in Silicon nano-membranes via electron diffraction with picosecond resolution. In these first experiments, electrons were injected in the density gradients located at the plasma exit, resulting in rather low energies in the 100 keV range. The electrons being nonrelativistic, the bunch duration quickly becomes picosecond long. Relativistic energies are required to mitigate space charge effects and maintain femtosecond bunches. In this paper, we will show very recent results where electrons are accelerated in laser-driven wakefields to relativistic energies, reaching up to 5 MeV at kHz repetition rate. The electron energy was increased by nearly two orders of magnitude by using single-cycle laser pulses of 3.5 fs, with only 2.5 mJ of energy. Using such short pulses of light allowed us to resonantly excite high amplitude and nonlinear plasma waves at high plasma density, ne=1.5-2×1020 cm-3, in a regime close to the blow-out regime. Electrons had a peaked distribution around 5 MeV, with a relative energy spread of 30 %. Charges in the 100's fC/shot and up to pC/shot where measured depending on plasma density. The electron beam was fairly collimated, 20 mrad divergence at Full Width Half Maximum. The results show remarkable stability of the beam parameters in terms of beam pointing and electron distribution. 3D PIC simulations reproduce the results very well and indicate that electrons are injected by the ionization of Nitrogen atoms, N5+ to N6

  8. The application of interference fits for overcoming limitations in clamping methodologies for cryo-cooling first crystal configurations in x-ray monochromators

    Science.gov (United States)

    Stimson, J.; Docker, P.; Ward, M.; Kay, J.; Chapon, L.; Diaz-Moreno, S.

    2017-12-01

    The work detailed here describes how a novel approach has been applied to overcome the challenging task of cryo-cooling the first monochromator crystals of many of the world’s synchrotrons’ more challenging beam lines. The beam line configuration investigated in this work requires the crystal to diffract 15 Watts of 4-34 keV X-ray wavelength and dissipate the additional 485 watts of redundant X-ray power without significant deformation of the crystal surface. In this case the beam foot print is 25 mm by 25 mm on a crystal surface measuring 38 mm by 25 mm and maintain a radius of curvature of more than 50 km. Currently the crystal is clamped between two copper heat exchangers which have LN2 flowing through them. There are two conditions that must be met simultaneously in this scenario: the crystal needs to be clamped strongly enough to prevent the thermal deformation developing whilst being loose enough not to mechanically deform the diffracting surface. An additional source of error also occurs as the configuration is assembled by hand, leading to human error in the assembly procedure. This new approach explores making the first crystal cylindrical with a sleeve heat exchanger. By manufacturing the copper sleeve to be slightly larger than the silicon crystal at room temperature the sleeve can be slid over the silicon and when cooled will form an interference fit. This has the additional advantage that the crystal and its heat exchanger become a single entity and will always perform the same way each time it is used, eliminating error due to assembly. Various fits have been explored to investigate the associated crystal surface deformations under such a regime

  9. The plastic instability of clamped-clamped conical thin-walled pipe reducers

    International Nuclear Information System (INIS)

    Awad, Ibrahim; Saleh, Ch.A.R.; Ragab, A.R.

    2016-01-01

    The analytical study for plastic deformation of clamped–clamped conical reducer pipe under internal pressure does not deduce a closed form expression for the pressure at plastic instability. The presented study employs finite element analysis (FEA) to estimate the internal pressure at instability for conical reducers made of different materials and having different dimensional configurations. Forty dimensional configurations, classified as medium type, and five types of materials have been included in the analysis using ABAQUS package. A correlation expression is derived by nonlinear regression to predict the instability pressure. The proposed expression is verified for other dimensional configurations out of the above used forty models and for other materials. Experiments have been conducted by pressurizing conical clamped-clamped reducers until bursting in order to verify the finite element models. Comparison of instability pressures, strains and deflections at specific points along the conical surface shows satisfactory agreement between analysis and experiments. - Highlights: • This study offers a parametric study of the plastic instability pressure of clamped-clamped conical reducers. • A closed form analytical expression for the instability pressure is derived by using nonlinear regression. • The finite element analysis is validated by conducting bursting tests.

  10. Dental dam clamp adaptation method on carved gypsum cast.

    Science.gov (United States)

    Cazacu, N C E

    2014-01-01

    Dental Dam is the safest and most efficient isolation technique in endodontics and restorative dentistry, but it also used in esthetics, orthodontics, prosthetics, pedodontics and periodontology (for teeth immobilization). While in most cases the standard clamps are efficient, in some clinical situations clamp adaptation is mandatory in order to assure a tight contact on the tooth. The purpose of this study is to list the elements of the clamp, which should be modified in order to assure a secure constriction of the clamp on the anchor tooth, by using the carved gypsum cast method. 100 patients were examined, diagnosed and treated for various diagnoses like simple decay, gangrene, chronic apical periodontitis, and endodontic retreatments. The clamps used in this study were produced by Hu-Friedy, Hygenic, KKD, SDI, Hager & Werken. In 10 cases, the anchor tooth did not provide enough stability to the standard clamp--as provided by the producer. Therefore, we have done some adjustments to some of the elements of the clamp: the arch, the wings, the plateau, the active area, and the contact points. In 6 cases, major clamp adaptations on carved gypsum cast were imperative. The classic clamps cannot provide a grip to be enough in all the clinical cases due to the huge variety and position and implantation of the anchor teeth. Therefore, in such situations, the clamps should be adapted in order to provide stability and assure the safe isolation during the treatment. The modified clamps will be useful in similar cases, so they must be kept.

  11. Diagnostic Accuracy of Split-Bolus Single-Phase Contrast-Enhanced Cone-Beam CT for the Detection of Liver Tumors before Transarterial Chemoembolization.

    Science.gov (United States)

    Jonczyk, Martin; Chapiro, Julius; Collettini, Federico; Geisel, Dominik; Schnapauff, Dirk; Streitparth, Florian; Schmidt, Thomas; Hamm, Bernd; Gebauer, Bernhard; Wieners, Gero

    2017-10-01

    To evaluate detectability of hepatocellular carcinoma (HCC) using split-bolus cone-beam CT in intraindividual comparison between cone-beam CT and contrast-enhanced MR imaging. In a retrospective, single-center study, 28 patients with 85 HCC tumors were treated with transarterial chemoembolization between May 2015 and June 2016. All patients underwent arterial and hepatobiliary phase (HBP) MR imaging within 1 month before transarterial chemoembolization. Cone-beam CT images were acquired using a split-bolus contrast injection with 2 contrast injections and 1 cone-beam CT acquisition. Statistical analyses included Friedman 2-way analysis, Kendall coefficient of concordance, and Wilcoxon test. Tumor detectability was scored using a 5-point system (1 = best; 5 = worst) by 2 independent readers resulting in 170 evaluated tumors. Quantitative analysis included signal-to-noise and contrast-to-noise ratio and contrast measurements. P values cone-beam CT (2.91/2.73) and HBP MR imaging (2.93/2.21) compared with arterial MR imaging (3.72/3.05; P cone-beam CT and HBP MR imaging in terms of detectability (P = .154) and sensitivity for hypervascularized tumors. More tumors were identified on cone-beam CT (n = 121/170) than on arterial MR imaging (n = 94/170). Average contrast-to-noise ratio values of arterial and HBP MR imaging were higher than for cone-beam CT (7.79, 8.58, 4.43), whereas contrast values were higher for cone-beam CT than for MR imaging (0.11, 0.13, 0.97). Split-bolus cone-beam CT showed excellent detectability of HCC. Sensitivity is comparable to HBP MR imaging and better than arterial phase MR imaging. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  12. Unequal pressure distribution along the jaws of currently available vascular clamps: do we need a new aortic clamp?

    Science.gov (United States)

    Rylski, Bartosz; Schmid, Claudius; Beyersdorf, Friedhelm; Kari, Fabian Alexander; Kondov, Stoyan; Lutz, Lisa; Werner, Martin; Czerny, Martin; Siepe, Matthias

    2016-06-01

    The pressure along vascular clamp jaws may be unequally distributed, with greater pressure near the clamp hinge than at its top. Such unequal pressure distribution may cause aortic injury, especially in large aortas. We evaluated pressure distribution along different currently availably clamp jaws. Seven descending thoracic aortas from pigs (diameter 2.0-3.0 cm) were plainly dissected and all side arteries closed. Aortas were filled up with water and cross-clamped. The pressure inside the aorta was raised to 100 mmHg and the aorta was clamped so tightly that no water exited from the distal aortic end. Each aorta was clamped seven times at different sites with the following clamps: DeBakey, Satinsky, femoral, iliac, Chitwood, angled handle Fogarty and straight handle Fogarty. The pressure along the clamp jaws was measured with a pressure-detecting film placed between the clamp jaws and aorta. The collagen-fibre disorganization was examined in haemotoxylin-eosin- and Elastica van Gieson-stained tissue samples. The DeBakey clamp revealed the lowest maximum pressure along the clamp jaws after complete aortic occlusion (1.43 ± 0.49 MPa), whereas the Chitwood clamp's pressure was the highest (3.26 ± 1.93 MPa, P clamp displayed the lowest difference between maximum pressures across the jaws (33%), with the greatest difference measured in the iliac (72%) and Chitwood (66%) clamps. The highest collagen-fibre disorganization score was observed in the proximal-to-the-clamp-hinge quartile after clamping with the angled handle Fogarty (2.8 ± 0.4), straight handle Fogarty (2.3 ± 0.8) and Chitwood (2.3 ± 0.5) clamps. The pressure along clamp jaws is unequally distributed in all the currently available vascular clamps. The Chitwood clamp is associated with the highest maximum pressure during complete aortic occlusion and with the most unequal pressure distribution along the jaws. © The Author 2015. Published by Oxford University Press on behalf of the European Association

  13. SU-F-T-232: Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System

    Energy Technology Data Exchange (ETDEWEB)

    Ding, K [Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD (United States); Ji, T [Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD (United States); Department of Radiation Oncology, The First Hospital, China Medical University, Shenyang, Liaoning (China); Iordachita, I [Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD (United States); Velarde, E; Hyatt, J; Wong, J

    2016-06-15

    Purpose: Monthly quality assurance (QA) is time consuming for external beam radiation therapy, taking as long as 6–8 hours for each machine. It is due to the use and setup of multiple devices for different QA procedures. We have developed a single system with rotational capability for the measurement of both optical light and radiation which significantly reduces the time spent on Monthly QA. Methods: A single system using mirrors, a phosphor screen and a CCD camera is housed on a cylindrical motor so that it can rotate 360 degrees. For monthly QA, the system is placed on the patient couch of the medical accelerator with the plane of the phosphor screen at isocenter for all measurements. For optical QA such as optical distance indicator, room laser and light field, the optical image is collected directly with the camera. For radiation QA such as beam profile, MLC speed, picket-fence test, collimator rotation, table rotation and gantry rotation, a brass build-up plate is attached to the top of the phosphor screen. Two brass plates with islands of different thickness were designed for photon energy and electron energy constancy checks. Flex map, distortion map and uniformity map were developed to calibrate the motor bearing, camera/lens distortion, and the phosphor screen’s measured response across the field. Results: Following the TG142 guidelines for monthly QA with our system, the overall run time is reduced from 6–8 hours to 1.5 hours. Our system’s rotating design allows for quick testing of the gantry radiation isocenter test that is also independent of the sag of the gantry and the EPID. Conclusion: Our system significantly shortens the time needed for monthly QA by unifying the tests with a single system. Future work will be focused on extending the technology to Brachytherapy, IMRT and proton therapy QAs. This work is funded in part by a sponsor research grant from JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

  14. Wavefront measurement of single-mode quantum cascade laser beam for seed application in laser-produced plasma extreme ultraviolet system.

    Science.gov (United States)

    Nowak, Krzysztof M; Ohta, Takeshi; Suganuma, Takashi; Yokotsuka, Toshio; Fujimoto, Junichi; Mizoguchi, Hakaru

    2012-12-01

    Quantum cascade laser (QCL) is a very attractive seed source for a multikilowatt pulsed CO2 lasers applied for driving extreme ultraviolet emitting plasmas. In this Letter, we investigate output beam properties of a QCL designed to address P18 and P20 lines of 10.6 micron band of CO2 molecule. In particular, output beam quality and stability are investigated for the first time. A well-defined linear polarization and a single-mode operation enabled a use of phase retrieval method for full description of QCL output beam. A direct, multi-image numerical phase retrieval technique was developed and successfully applied to the measured intensity patterns of a QCL beam. Very good agreement between the measured and reconstructed beam profiles was observed at distances ranging from QCL aperture to infinity, proving a good understanding of the beam propagation. The results also confirm a high spatial coherence and high stability of the beam parameters, the features expected from an excellent seed source.

  15. Quantification of single-kidney glomerular filtration rate with electron-beam computed tomography

    Science.gov (United States)

    Lerman, Lilach O.; Ritman, Erik L.; Pelaez, Laura I.; Sheedy, Patrick F., II; Krier, James D.

    2000-04-01

    The ability to accurately and noninvasively quantify single- kidney GFR could be invaluable for assessment of renal function. We developed a model that enables this measurement with EBCT. To examine the reliability of this method, EBCT renal flow and volume studies after contrast media administration were performed in pigs with unilateral renal artery stenosis (Group 1), controls (Group 2), and simultaneously with inulin clearance (Group 3). Renal flow curves, obtained from the bilateral renal cortex and medulla, depicted transit of the contrast through the vascular and tubular compartments, and were fitted using extended gamma- variate functions. Renal blood flow was calculated as the sum of products of cortical and medullary perfusions and volumes. Normalized GFR (mL/min/cc) was calculated using the rate (maximal slope) of proximal tubular contrast accumulation, and EBCT-GFR as normalized GFR* cortical volume. In Group 1, the decreased GFR of the stenotic kidney correlated well with its decreased volume and RBF, and with the degree of stenosis (r equals -0.99). In Group 3, EBCT-GFR correlated well with inulin clearance (slope 1.1, r equals 0.81). This novel approach can be very useful for quantification of concurrent regional hemodynamics and function in the intact kidneys, in a manner potentially applicable to humans.

  16. Control and Analysis of a Single-Link Flexible Beam with Experimental Verification

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, J.F.

    1992-01-01

    The objective of this report is to ascertain the general conditions for the avoidance and reduction of residual vibration in a flexible manipulator. Conventional manipulators usually have a 1.5 to 2-m reach, and their associated dynamic models typically are composed of lumped parameter elements; the major compliance emanates from the, drive trains because of torsional loading effects. The energy storage of the drive system is predominantly potential energy because of the low inertia in the drive tram; thus simple spring models have been adequate. A long-reach manipulator with a large aspect ratio (length to diameter) is a fundamentally different problem. Energy storage for this type of manipulator is distributive by nature because of the potential energy resulting from bending and the kinetic energy due to deflection rates. Instead of ordinary differential equations, partial differential equations are required to describe this system, making the analysis more difficult. The general flexibility problem associated with a distributive dynamic system, with specific emphasis on flexible manipulator, will be addressed in this report. Furthermore, three control schemes will be discussed and demonstrated on, a single flexible manipulator to determine their general merits.

  17. Control and analysis of a single-link flexible beam with experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, J.F.

    1992-12-01

    The objective of this report is to ascertain the general conditions for the avoidance and reduction of residual vibration in a flexible manipulator. Conventional manipulators usually have a 1.5 to 2-m reach, and their associated dynamic models typically are composed of lumped parameter elements; the major compliance emanates from the drive trains because of torsional loading effects. The energy storage of the drive system is predominantly potential energy because of the low inertia in the drive train; thus simple spring models have been adequate. A long-reach manipulator with a large aspect ratio (length to diameter) is a fundamentally different problem. Energy storage for this type of manipulator is distributive by nature because of the potential energy resulting from bending and the kinetic energy due to deflection rates. Instead of ordinary differential equations, partial differential equations are required to describe this system, making the analysis more difficult. The general flexibility problem associated with a distributive dynamic system, with specific emphasis on flexible manipulator, will be addressed in this report. Furthermore, three control schemes will be discussed and demonstrated on a single flexible manipulator to determine their general merits.

  18. Modification of mechanical properties of single crystal aluminum oxide by ion beam induced structural changes

    International Nuclear Information System (INIS)

    Ensinger, W.; Nowak, R.; Horino, Y.; Baba, K.

    1993-01-01

    The mechanical behaviour of ceramics is essentially determined by their surface qualities. As a surface modification technique, ion implantation provides the possibility to modify the mechanical properties of ceramics. Highly energetic ions are implanted into the near-surface region of a material and modify its composition and structure. Ions of aluminum, oxygen, nickel and tantalum were implanted into single-crystal α-aluminum oxide. Three-point bending tests showed that an increase in flexural strength of up to 30% could be obtained after implantation of aluminum and oxygen. Nickel and tantalum ion implantation increased the fracture toughness. Indentation tests with Knoop and Vickers diamonds and comparison of the lengths of the developed radial cracks showed that ion implantation leads to a reaction in cracking. The observed effects are assigned to radiation induced structural changes of the ceramic. Ion bombardment leads to radiation damage and formation of compressive stress. In case of tantalum implantation, the implanted near-surface zone becomes amorphous. These effects make the ceramic more resistant to fracture. (orig.)

  19. Thon rings from amorphous ice and implications of beam-induced Brownian motion in single particle electron cryo-microscopy.

    Science.gov (United States)

    McMullan, G; Vinothkumar, K R; Henderson, R

    2015-11-01

    We have recorded dose-fractionated electron cryo-microscope images of thin films of pure flash-frozen amorphous ice and pre-irradiated amorphous carbon on a Falcon II direct electron detector using 300 keV electrons. We observe Thon rings [1] in both the power spectrum of the summed frames and the sum of power spectra from the individual frames. The Thon rings from amorphous carbon images are always more visible in the power spectrum of the summed frames whereas those of amorphous ice are more visible in the sum of power spectra from the individual frames. This difference indicates that while pre-irradiated carbon behaves like a solid during the exposure, amorphous ice behaves like a fluid with the individual water molecules undergoing beam-induced motion. Using the measured variation in the power spectra amplitude with number of electrons per image we deduce that water molecules are randomly displaced by a mean squared distance of ∼1.1 Å(2) for every incident 300 keV e(-)/Å(2). The induced motion leads to an optimal exposure with 300 keV electrons of 4.0 e(-)/Å(2) per image with which to observe Thon rings centred around the strong 3.7 Å scattering peak from amorphous ice. The beam-induced movement of the water molecules generates pseudo-Brownian motion of embedded macromolecules. The resulting blurring of single particle images contributes an additional term, on top of that from radiation damage, to the minimum achievable B-factor for macromolecular structure determination. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Tumor induction in mice after local irradiation with single doses of either carbon-ion beams or gamma rays.

    Science.gov (United States)

    Ando, Koichi; Koike, Sachiko; Ohmachi, Yasushi; Ando, Yutaka; Kobashi, Gen

    2014-12-01

    To determine the dose-dependent relative biological effectiveness (RBE) for tumor prevalence in mice receiving single localized doses to their right leg of either carbon ions (15, 45 or 75 keV/μm) or 137Cs gamma rays. A total of 1647 female C3H mice were irradiated to their hind legs with a localized dose of either reference gamma rays or 15, 45 or 75 keV/μm carbon-ion beams. Irradiated mice were evaluated for tumors twice a month during their three-year life span, and the dimensions of any tumors found were measured with a caliper. The tumor induction frequency was calculated by Kaplan-Meier analysis. The incidence of tumors from 50 Gy of 45 keV/μm carbon ions was marginally higher than those from 50 Gy of gamma rays. However, 60 Gy of 15 keV/μm carbon ions induced significantly fewer tumors than did gamma rays. RBE values of 0.87 + 0.12, 1.29 + 0.08 or 2.06 + 0.39 for lifetime tumorigenesis were calculated for 15, 45 or 75 keV/μm carbon-ion beams, respectively. Fibrosarcoma predominated, with no Linear Energy Transfer (LET)-dependent differences in the tumor histology. Experiments measuring the late effect of leg skin shrinkage suggested that the carcinogenic damage of 15 keV/μm carbon ions would be less than that of gamma rays. We conclude that patients receiving radiation doses to their normal tissues would face less risk of secondary tumor induction by carbon ions of intermediate LET values compared to equivalent doses of photons.

  1. Combined Triplex/Duplex Invasion of Double-Stranded DNA by "Tail-Clamp" Peptide Nucleic Acid

    DEFF Research Database (Denmark)

    Bentin, Thomas; Larsen, H. J.; Nielsen, Peter E.

    2003-01-01

    "Tail-clamp" PNAs composed of a short (hexamer) homopyrimidine triplex forming domain and a (decamer) mixed sequence duplex forming extension have been designed. Tail-clamp PNAs display significantly increased binding to single-stranded DNA compared with PNAs lacking a duplex-forming extension...... as determined by T-m measurements. Binding to double-stranded (ds) DNA occurred by combined triplex and duplex invasion as analyzed by permanganate probing. Furthermore, C-50 measurements revealed that tail-clamp PNAs consistently bound the dsDNA target more efficiently, and kinetics experiments revealed...... to five residues was feasible, but four bases were not sufficient to yield detectable dsDNA binding. The results validate the tail-clamp PNA concept and expand the applications of the P-loop technology....

  2. Increased of the capacity integral bridge with reinforced concrete beams for single span

    Science.gov (United States)

    Setiati, N. Retno

    2017-11-01

    Sinapeul Bridge that was built in 2012 in Sumedang is a bridge type using a full integral system. The prototype of integral bridge with reinforced concrete girder and single span 20 meters until this year had decreased capacity. The bridge was conducted monitoring of strain that occurs in the abutment in 2014. Monitoring results show that based on the data recorded, the maximum strain occurs at the abutment on the location of the integration of the girder of 10.59 x 10-6 tensile stress of 0.25 MPa (smaller than 150 x 10-6) with 3 MPa tensile stress as limit the occurrence of cracks in concrete. Sinapeul bridge abutment with integral system is still in the intact condition. Deflection of the bridge at the time of load test is 1.31 mm. But this time the bridge has decreased exceeded permission deflection (deflection occurred by 40 mm). Besides that, the slab also suffered destruction. One cause of the destruction of the bridge slab is the load factor. It is necessary for required effort to increase the capacity of the integral bridge with retrofitting. Retrofitting method also aims to restore the capacity of the bridge structure due to deterioration. Retrofitting can be done by shortening of the span or using Fibre Reinforced Polymer (FRC). Based on the results obtained by analysis of that method of retrofitting with Fibre Reinforced Polymer (FRC) is more simple and effective. Retrofitting with FRP can increase the capacity of the shear and bending moment becomes 41% of the existing bridge. Retrofitting with FRP method does not change the integral system on the bridge Sinapeul become conventional bridges.

  3. Single grain boundary break junction for suspended nanogap electrodes with gapwidth down to 1-2 nm by focused ion beam milling.

    Science.gov (United States)

    Cui, Ajuan; Liu, Zhe; Dong, Huanli; Wang, Yujin; Zhen, Yonggang; Li, Wuxia; Li, Junjie; Gu, Changzhi; Hu, Wenping

    2015-05-20

    Single grain boundary junctions are used for the fabrication of suspended nanogap electrodes with a gapwidth down to 1-2 nm through the break of such junctions by focused ion beam (FIB) milling. With advantages of stability and no debris, such nanogap electrodes are suitable for single molecular electronic device construction. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A model-based analysis of a simplified beam-specific dose output in proton therapy with a single-ring wobbling system.

    Science.gov (United States)

    Kase, Yuki; Yamashita, Haruo; Numano, Masumi; Sakama, Makoto; Mizota, Manabu; Maeda, Yoshikazu; Tameshige, Yuji; Murayama, Shigeyuki

    2015-01-07

    In radiation therapy, it is necessary to preset a monitor unit in an irradiation control system to deliver a prescribed absolute dose to a reference point in the planning target volume. The purpose of this study was to develop a model-based monitor unit calculation method for proton-beam therapy with a single-ring wobbling system. The absorbed dose at a calibration point per monitor unit had been measured for each beam-specific measurement condition without a patient-specific collimator or range compensator before proton therapeutic irradiation at Shizuoka Cancer Center. In this paper, we propose a simplified dose output model to obtain the output ratio between a beam-specific dose and a reference field dose, from which a monitor unit for the proton treatment could be derived without beam-specific measurements. The model parameters were determined to fit some typical data measured in a proton treatment room, called a Gantry 1 course. Then, the model calculation was compared with 5456 dose output ratios that had been measured for 150-, 190- and 220 MeV therapeutic proton beams in two treatment rooms over the past decade. The mean value and standard deviation of the difference between the measurement and the model calculation were respectively 0.00% and 0.27% for the Gantry 1 course, and -0.25% and 0.35% for the Gantry 2 course. The model calculation was in good agreement with the measured beam-specific doses, within 1%, except for conditions less frequently used for treatment. The small variation for the various beam conditions shows the high long-term reproducibility of the measurement and high degree of compatibility of the two treatment rooms. Therefore, the model was expected to assure the setting value of the dose monitor for treatment, to save the effort required for beam-specific measurement, and to predict the dose output for new beam conditions in the future.

  5. Evaluation of fracture toughness in dental ceramics using indentation and SEVNB (Single Edge V-Notched Beam)-method; Avaliacao da tenacidade a fratura de ceramicas dentarias atraves do metodo de entalhe - SEVNB (Single Edge V-Notched Beam)

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L.A.; Santos, C.; Souza, R.C.; Ribeiro, S. [Universidade de Sao Paulo (DEMAR/EEL/USP), Lorena, SP (Brazil). Escola de Engenharia de Lorena. Dept. de Engenharia de Materiais. Polo Urbo-Industrial; Strecker, K. [Universidade Federal de Sao Joao del-Rei (DME/UFSJ), MG (Brazil). Dept. de Materiais Eletricos; Oberacker, R. [Karlsruhe Univ. (Germany)

    2009-07-01

    In this work, the fracture toughness of different ceramics based on Al{sub 2}O{sub 3} and ZrO{sub 2} were evaluated using, comparatively two methods, Vickers indentation and SEVNB (Single Edge V-Notched Beam) method. Al{sub 2}O{sub 3}, ZrO{sub 2}(3%Y{sub 2}O{sub 3}) micro-particled and ZrO{sub 2}(3%Y{sub 2}O{sub 3}) nanometric, ZrO{sub 2}-Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}-ZrO{sub 2} composites were sintered at different temperatures. Samples were characterized by relative density, X-ray diffraction, SEM, and mechanical evaluation by hardness, bending strength and fracture toughness obtained by ickers indentation and SEVNB-method. The results were presented comparing the densification and microstructural results. Furthermore, the advantages and limitations of each method were discussed. (author)

  6. Bingham Sealing and Application in Vacuum Clamping

    Science.gov (United States)

    Yao, S. M.; Teo, Wee Kin; Geng, Zunmin; Turner, Sam; Ridgway, Keith

    2011-12-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of "O"ring sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with "O" ring sealing.

  7. Bingham Sealing and Application in Vacuum Clamping

    International Nuclear Information System (INIS)

    Yao, S M; Teo, Wee Kin; Geng Zunmin; Turner, Sam; Ridgway, Keith

    2011-01-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of Or ing sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with 'O' ring sealing.

  8. The influence of single and fractionated dose external beam irradiation on injury-induced arterial smooth muscle cell proliferation

    International Nuclear Information System (INIS)

    Schaefer, U.; Micke, O.; Dorszewski, A.; Breithardt, G.; Willich, N.

    1997-01-01

    Purpose/Objective: Restenosis after catheter-based revascularization has been demonstrated to be primarily caused by smooth muscle cell proliferation. This study examined the effects of external beam irradiation on neointimal proliferation after external injury to the central artery of the rabbit ear. Materials and Methods: 40 male New Zealand White rabbits were used in this study. Crush lesions were performed on each ear under general anesthesia and bilateral auricular nerve blockade. A single dose of 12 Gy (n=10), 16 Gy (n=10), or 20 Gy (n=10) and a fractionated dose of 4 x 5 Gy (n=10) gamma radiation was delivered to the left or right central artery of the ear 24 hours after injury; the contralateral central artery served as control. All rabbits were sacrificed after twenty-one days and the central arteries of the ear were fixed for morphometric measurements. Results: Mean (± SD) neointimal area was 0.062 ± 0.005 mm 2 (12 Gy), 0.022 ± 0,005 mm 2 (16 Gy), 0,028 ± 0,006 mm 2 and 0.038 mm 2 ± 0,02 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,081 ± 0,009 mm 2 in the control group. Mean (±SD) luminal area was 0.049 ± 0.004 mm 2 (12 Gy), 0.059 ± 0.002 mm 2 (16 Gy), 0.072 ± 0,006 mm 2 (20 Gy) and 0.048 mm 2 ± 0,018 mm 2 (4 x 5 Gy) in irradiated arteries compared with 0,043 ± 0,008 mm 2 in the control group. The difference in neointimal and luminal area between control and irradiated arteries was significant (p<0.05) only for the 16 and 20 Gy group compared to control. Conclusion: We conclude that in this model, external beam X-ray irradiation was successful in reducing neointimal proliferation after injury of the central artery of the rabbit ear. The optimal dose seems to be a single dose of 16 Gy - 20 Gy. Only a less prominent effect was noted for a fractionated dose of 4 x 5 Gy. Whether this approach can be used successfully to inhibit restenosis in the clinical setting requires further investigation

  9. Influence of squeeze film damping on the higher-order modes of clamped–clamped microbeams

    KAUST Repository

    Alcheikh, Nouha

    2016-05-06

    This paper presents an experimental study and a finite-element analysis of the effect of squeeze film damping on the resonance frequency and quality factor of the higher-order flexure vibrations modes of clamped-clamped microbeams. Viscoelastic and silicon nitride microbeams are fabricated and are electrostatically actuated by various electrode configurations to trigger the first, second, and third modes. The damping characteristic and the resonance frequency of these modes are examined for a wide range of gas pressure and electrostatic voltage loads. The results of the silicon nitride beams and viscoelastic beams are compared. It is found that the intrinsic material loss is the major dissipation mechanism at low pressure for the viscoelastic microbeams, significantly limiting their quality factor. It is also found that while the silicon nitride beams show higher quality factors at the intrinsic and molecular regimes of pressure, due to their low intrinsic loss, their quality factors near atmospheric pressure are lower than those of the viscoelastic microbeams. Further, the higher-order modes of all the beams show much higher quality factors at atmospheric pressure compared to the first mode, which could be promising for operating such resonators in air. Experimental results and finite element model simulations show good agreement for resonance frequency and quality factor for the three studied modes. © 2016 IOP Publishing Ltd.

  10. Improving safety and efficiency during emergent central venous catheter placement with a needleless securing clamp.

    Science.gov (United States)

    Silich, Bert; Chrobak, Paul; Siu, Jeffrey; Schlichting, Adam; Patel, Samir; Yang, James

    2013-08-01

    To compare the needleless securing clamp to the traditional suture-secured clamp for central venous catheters. Compare the holding strength of each type of clamps by measuring the amount of kinetic energy absorbed, ask 20 physicians to evaluate the clamp placement using sutures or staples, and summarise the clamps effectiveness and complications in 10 patients. Compared to sutured clamp, the needleless clamp was more secure. The needleless clamp was also significantly better with regard to ease of use, safety, perceived strength (p value clamps. Without incurring complications or increasing risk to patients, the needleless clamp is secure and improves safety and efficiency for physicians.

  11. SU-F-T-501: Dosimetric Comparison of Single Arc-Per-Beam and Two Arc-Per-Beam VMAT Optimization in the Monaco Treatment Planning System

    Energy Technology Data Exchange (ETDEWEB)

    Kalet, A; Cao, N; Meyer, J; Dempsey, C [University of Washington Medical Center, Seattle, WA (United States); Seattle Cancer Care Alliance, Seattle, WA (United States); Richardson, H [Seattle Cancer Care Alliance, Seattle, WA (United States)

    2016-06-15

    Purpose: The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. Methods: A total of 17 previously treated patients were selected for this study with a range of pelvic disease site including prostate(9), bladder(1), uterus(3), rectum(3), and cervix(1). For each patient, two plans were generated, one using a arc-per-beam setting of ‘1’ and another with setting of ‘2’. The setting allows the optimizer to add a gantry direction change, creating multiple arc passes per beam sequence. Volumes and constraints established from the initial clinical treatments were used for planning. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the PTV received 95% of the prescription dose. We evaluated the PTV conformity index, homogeneity index, total monitor units, number of control points, and various dose volume histogram (DVH) points for statistical comparison (alpha=0.05). Results: We found for the 10 complex shaped target volumes (small central volumes with extending bilateral ‘arms’ to cover nodal regions) that the use of 2 arcs-per-beam achieved significantly lower average DVH values for the bladder V20 (p=0.036) and rectum V30 (p=0.001) while still meeting the high dose target constraints. DVH values for the simpler, more spherical PTVs were not found significantly different. Additionally, we found a beam delivery time reduction of approximately 25%. Conclusion: In summary, the dosimetric benefit, while moderate, was improved over a 1 arc-per-beam setting for complex PTVs, and equivalent in other cases. The overall reduced delivery time suggests that the use of multiple arcs-per-beam could lead to reduced patient on table time, increased clinical throughput, and reduced medical physics quality assurance effort.

  12. The β Sliding Clamp Closes around DNA prior to Release by the Escherichia coli Clamp Loader γ Complex*

    Science.gov (United States)

    Hayner, Jaclyn N.; Bloom, Linda B.

    2013-01-01

    Escherichia coli γ complex clamp loader functions to load the β sliding clamp onto sites of DNA replication and repair. The clamp loader uses the energy of ATP binding and hydrolysis to drive conformational changes allowing for β binding and opening, DNA binding, and then release of the β·DNA complex. Although much work has been done studying the sliding clamp and clamp loader mechanism, kinetic analysis of the events following β·γ complex·DNA formation is not complete. Using fluorescent clamp closing and release assays, we show that β closing is faster than β release, indicating that γ complex closes β before releasing it around DNA. Using a fluorescent ATP hydrolysis assay, we show that there is a burst of ATP hydrolysis before β closing and that β release may be the rate-limiting step in the overall clamp loading reaction. The combined use of these fluorescent assays provides a unique perspective into the E. coli clamp loader by providing a measure of the relative timing of different events in the clamp loading reaction, helping to elucidate the complicated clamp loading mechanism. PMID:23161545

  13. Vertical dynamics of a single-span beam subjected to moving mass-suspended payload system with variable speeds

    Science.gov (United States)

    He, Wei

    2018-03-01

    This paper presents the vertical dynamics of a simply supported Euler-Bernoulli beam subjected to a moving mass-suspended payload system of variable velocities. A planar theoretical model of the moving mass-suspended payload system of variable speeds is developed based on several assumptions: the rope is massless and rigid, and its length keeps constant; the stiffness of the gantry beam is much greater than the supporting beam, and the gantry beam can be treated as a mass particle traveling along the supporting beam; the supporting beam is assumed as a simply supported Bernoulli-Euler beam. The model can be degenerated to consider two classical cases-the moving mass case and the moving payload case. The proposed model is verified using both numerical and experimental methods. To further investigate the effect of possible influential factors, numerical examples are conducted covering a range of parameters, such as variable speeds (acceleration or deceleration), mass ratios of the payload to the total moving load, and the pendulum lengths. The effect of beam flexibility on swing response of the payload is also investigated. It is shown that the effect of a variable speed is significant for the deflections of the beam. The accelerating movement tends to induce larger beam deflections, while the decelerating movement smaller ones. For accelerating or decelerating movements, the moving mass model may underestimate the deflections of the beam compared with the presented model; while for uniform motion, both the moving mass model and the moving mass-payload model lead to same beam responses. Furthermore, it is observed that the swing response of the payload is not sensitive to the stiffness of the beam for operational cases of a moving crane, thus a simple moving payload model can be employed in the swing control of the payload.

  14. In vivo fracture of a new rubber-dam clamp.

    Science.gov (United States)

    Zinelis, S; Margelos, J

    2002-08-01

    This study was carried out to investigate the reasons for fracture of a new rubber-dam clamp used for the first time. The fractured surfaces of the broken clamp were studied with optical microscopy. Characteristic surface patterns of tensile fracture were identified. Cracks originated from the groove of letter D mechanically engraved on the inner surface of the clamp bow, and developed with high velocity (unstable crack growth rate) leading to catastrophic fracture. This behaviour was attributed to the residual stresses introduced by the labelling technique due to local thermal alterations. The labelling technique used to number clamps may be implicated with catastrophic failure. Dentists should be aware that even new clamps can fracture. It is important that clamps are secured to prevent inhalation of metal fragments, should catastrophic failure occur.

  15. Design of a hot clamp for small diameter LMFBR piping

    International Nuclear Information System (INIS)

    Jones, J.W.; Hamel, D.

    1980-01-01

    In order to evaluate the feasibility of using a strap-type clamp on breeder reactor small diameter piping, a series of analyses were conducted to determine the thermal and mechanical stresses induced in the pipe by the clamp. The effect of using a thin layer of insulation of varying thickness between the pipe and clamp was also investigated. A thermal analysis of the pipe and clamp was conducted for each thermal transient rate. Various insulation values ranging from metal-to-metal condition to perfect insulation between the pipe and clamp were analyzed to determine the effect of insulating the pipe from the clamp. An axisymmetric finite element model was used to determine the axial thermal and stress patterns

  16. Type IA topoisomerase inhibition by clamp closure.

    Science.gov (United States)

    Leelaram, Majety Naga; Bhat, Anuradha Gopal; Godbole, Adwait Anand; Bhat, Rajeshwari Subray; Manjunath, Ramanathapuram; Nagaraja, Valakunja

    2013-08-01

    Bacterial DNA topoisomerase I (topoI) catalyzes relaxation of negatively supercoiled DNA. The enzyme alters DNA topology through protein-operated DNA gate, switching between open and closed conformations during its reaction. We describe the mechanism of inhibition of Mycobacterium smegmatis and Mycobacterium tuberculosis topoI by monoclonal antibodies (mAbs) that bind with high affinity and inhibit at 10-50 nM concentration. Unlike other inhibitors of topoisomerases, the mAbs inhibited several steps of relaxation reaction, namely DNA binding, cleavage, strand passage, and enzyme-DNA dissociation. The enhanced religation of the cleaved DNA in presence of the mAb indicated closing of the enzyme DNA gate. The formation of enzyme-DNA heterocatenane in the presence of the mAbs as a result of closing the gate could be inferred by the salt resistance of the complex, visualized by atomic force microscopy and confirmed by fluorescence measurements. Locking the enzyme-DNA complex as a closed clamp restricted the movements of the DNA gate, affecting all of the major steps of the relaxation reaction. Enzyme trapped on DNA in closed clamp conformation formed roadblock for the elongating DNA polymerase. The unusual multistep inhibition of mycobacterial topoisomerases may facilitate lead molecule development, and the mAbs would also serve as valuable tools to probe the enzyme mechanism.

  17. Evaluation of a Single-Beam Sonar System to Map Seagrass at Two Sites in Northern Puget Sound, Washington

    Science.gov (United States)

    Stevens, Andrew W.; Lacy, Jessica R.; Finlayson, David P.; Gelfenbaum, Guy

    2008-01-01

    Seagrass at two sites in northern Puget Sound, Possession Point and nearby Browns Bay, was mapped using both a single-beam sonar and underwater video camera. The acoustic and underwater video data were compared to evaluate the accuracy of acoustic estimates of seagrass cover. The accuracy of the acoustic method was calculated for three classifications of seagrass observed in underwater video: bare (no seagrass), patchy seagrass, and continuous seagrass. Acoustic and underwater video methods agreed in 92 percent and 74 percent of observations made in bare and continuous areas, respectively. However, in patchy seagrass, the agreement between acoustic and underwater video was poor (43 percent). The poor agreement between the two methods in areas with patchy seagrass is likely because the two instruments were not precisely colocated. The distribution of seagrass at the two sites differed both in overall percent vegetated and in the distribution of percent cover versus depth. On the basis of acoustic data, seagrass inhabited 0.29 km2 (19 percent of total area) at Possession Point and 0.043 km2 (5 percent of total area) at the Browns Bay study site. The depth distribution at the two sites was markedly different. Whereas the majority of seagrass at Possession Point occurred between -0.5 and -1.5 m MLLW, most seagrass at Browns Bay occurred at a greater depth, between -2.25 and -3.5 m MLLW. Further investigation of the anthropogenic and natural factors causing these differences in distribution is needed.

  18. Determination of a cross-sectional void fraction in a tube bundle using a single beam gamma densitometer

    International Nuclear Information System (INIS)

    Guichard, J.; Mezoul, B.; Peturaud, P.; Thomas, B.

    1991-06-01

    In order to qualify 3-dimensional two-phase flow computer codes modelling average flows in tube bundles, cross-section average void fractions must be measured over sub-channels. On the VATICAN mockup, such void fractions(integrated on the mockup thickness) are determined using a single (narrow) beam gamma densitometer. But to avoid a refined exploration of each measurement mesh, for each test, empirical calibration curves have been developed in a regular mesh of the mockup, in axial flow conditions. These calibration curves, which evaluate the sought cross-sectional value as a function of a chordal void fraction (right in the inter-rod gap) depend only on heat flux density and pressure. The data are consistent with the ARMAND-MASSENA and LELLOUCHE-ZOLOTAR slip correlations, and they are fitted by 3rd degree polynomials, for each heat flux density investigated, with a good accuracy. Unfortunately, preliminary testing and analysis indicate that the use of these calibration curves in subcooled boiling and transverse mixing zones might result in significant uncertainties and errors

  19. Single-beam image encryption using spatially separated ciphertexts based on interference principle in the Fresnel domain

    Science.gov (United States)

    Wang, Qu; Guo, Qing; Lei, Liang; Zhou, Jinyun

    2014-12-01

    A new optical security system for image encryption based on optical interference principle and translation property of Fresnel transform (FrT) has been proposed in this article. The algorithm of this proposal is specially designed for single-beam optical decryption and can thoroughly resolve the silhouette problem existing in the previous interference-based scheme. Different from earlier schemes using interference of phase-only masks (POMs), the inverse FrT of primitive image is digitally decomposed into a random POM and a complex field distribution. Information associated with the primitive images can be completely smoothed away by the modulation of this random POM. Through the translation property of FrT, two linear phase-only terms are then used to modulate the obtained random POM and the complex distribution, respectively. Two complex ciphertexts are generated by performing digital inverse FrT again. One cannot recover any visible information of secret image using only one ciphertext. Moreover, to recover the primitive image correctly, the correct ciphertexts must be placed in the certain positions of input plane of decryption system, respectively. As additional keys, position center coordinates of ciphertexts can increase the security strength of this encryption system against brute force attacks greatly. Numerical simulations have been given to verify the performance and feasibility of this proposal. To further enhance the application value of this algorithm, an alternative approach based on Fourier transform has also been discussed briefly.

  20. Strain engineering and one-dimensional organization of metal-insulator domains in single-crystal vanadium dioxide beams.

    Science.gov (United States)

    Cao, J; Ertekin, E; Srinivasan, V; Fan, W; Huang, S; Zheng, H; Yim, J W L; Khanal, D R; Ogletree, D F; Grossman, J C; Wu, J

    2009-11-01

    Correlated electron materials can undergo a variety of phase transitions, including superconductivity, the metal-insulator transition and colossal magnetoresistance. Moreover, multiple physical phases or domains with dimensions of nanometres to micrometres can coexist in these materials at temperatures where a pure phase is expected. Making use of the properties of correlated electron materials in device applications will require the ability to control domain structures and phase transitions in these materials. Lattice strain has been shown to cause the coexistence of metallic and insulating phases in the Mott insulator VO(2). Here, we show that we can nucleate and manipulate ordered arrays of metallic and insulating domains along single-crystal beams of VO(2) by continuously tuning the strain over a wide range of values. The Mott transition between a low-temperature insulating phase and a high-temperature metallic phase usually occurs at 341 K in VO(2), but the active control of strain allows us to reduce this transition temperature to room temperature. In addition to device applications, the ability to control the phase structure of VO(2) with strain could lead to a deeper understanding of the correlated electron materials in general.

  1. Medial Clamp Tine Positioning Affects Ankle Syndesmosis Malreduction.

    Science.gov (United States)

    Cosgrove, Christopher T; Putnam, Sara M; Cherney, Steven M; Ricci, William M; Spraggs-Hughes, Amanda; McAndrew, Christopher M; Gardner, Michael J

    2017-08-01

    To determine whether the position of the medial clamp tine during syndesmotic reduction affected reduction accuracy. Prospective cohort. Urban Level 1 trauma center. Seventy-two patients with operatively treated syndesmotic injuries. Patients underwent operative fixation of their ankle syndesmotic injuries using reduction forceps. The position of the medial clamp tine was then recorded with intraoperative fluoroscopy. Malreduction rates were then assessed with bilateral ankle computerized tomography. Fibular position within the incisura was measured with respect to the uninjured side to determine whether a malreduction had occurred. Malreductions were then analyzed for associations with injury pattern, patient demographics, and the location of the medial clamp tine. A statistically significant association was found between medial clamp position and sagittal plane syndesmosis malreduction. In reference to anterior fibular translation, there was a 0% malreduction rate in the 18 patients where the clamp tine was placed in the anterior third, a 19.4% malreduction rate in the middle third, and 60% malreduction rate in the posterior third (P = 0.006). In reference to posterior fibular translation, there was a 11.1% malreduction when clamp placement was in the anterior third, a 16.1% malreduction rate in the middle third, and 60% malreduction rate in the posterior third (P = 0.062). There were no significant associations between medial clamp position and coronal plane malreductions (overcompression or undercompression) (P = 1). When using reduction forceps for syndesmotic reduction, the position of the medial clamp tine can be highly variable. The angle created with off-axis syndesmotic clamping is likely a major culprit in iatrogenic malreduction. Sagittal plane malreduction appears to be highly sensitive to clamp obliquity, which is directly related to the medial clamp tine placement. Based on these data, we recommend placing the medial clamp tine in the anterior third

  2. Ion optics study in a single-beamlet system for the 160-keV Joint European Torus neutral beam injectors

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Bussac, J.P.; Jequier, F.

    1986-01-01

    The optics of the 160-keV deuterium neutral beam injection for the Joint European Torus--plug-in neutral injector (JET-PINI) have been studied in a single beamlet, using the test stand ligne d'etudes d'optiques (LEO). The beamlet optical features, that is perveance-divergence relationships, beam profiles, and steering angle by aperture offset, have been measured. Computations have been compared with the experimental results obtained both in this monobeamlet experiment and in the multibeamlet system of the 160-keV PINI injector

  3. Ion optics study in a single-beamlet system for the 160-keV Joint European Torus neutral beam injectors

    Energy Technology Data Exchange (ETDEWEB)

    Bottiglioni, F.; Bussac, J.P.; Jequier, F.

    1986-09-01

    The optics of the 160-keV deuterium neutral beam injection for the Joint European Torus--plug-in neutral injector (JET-PINI) have been studied in a single beamlet, using the test stand ligne d'etudes d'optiques (LEO). The beamlet optical features, that is perveance-divergence relationships, beam profiles, and steering angle by aperture offset, have been measured. Computations have been compared with the experimental results obtained both in this monobeamlet experiment and in the multibeamlet system of the 160-keV PINI injector.

  4. Obstetricians' attitudes and beliefs regarding umbilical cord clamping.

    Science.gov (United States)

    Jelin, Angie C; Kuppermann, Miriam; Erickson, Kristine; Clyman, Ronald; Schulkin, Jay

    2014-09-01

    Although delayed umbilical cord clamping has been demonstrated to reduce the incidence of intraventricular hemorrhage and neonatal sepsis, and decrease the need for neonatal transfusions (without affecting cord pH, Apgar scores or the need for phototherapy), the extent to which this practice is being employed is unknown. We conducted a survey of US obstetricians to assess their attitudes and beliefs about cord clamping. Questionnaires were randomly mailed to members of the American College of Obstetricians and Gynecologists (ACOG), and the Collaborative Ambulatory Research Network (CARN). The data were analyzed using Chi-square and Student t tests. The response rates for the CARN and other ACOG members were 47% and 21%, respectively. Most (88%) responders reported their hospital had no umbilical cord clamping policy. The most frequent response for optimal timing of umbilical cord clamping, regardless of gestational age, was "don't know". Potential for neonatal red blood cell transfusion was the only concern cited as a reason for being somewhat or very inclined to delay umbilical cord clamping (51%). Delayed neonatal resuscitation (76%) was listed as a reason to clamp the cord immediately, despite the paucity of literature to support immediate cord clamping in this cohort. Despite substantial evidence supporting the practice of delayed cord clamping, few institutions have policies regarding this practice. Moreover, obstetricians' beliefs about the appropriate timing for umbilical cord clamping are not consistent with the evidence that demonstrates its beneficial impact on neonatal outcomes.

  5. Off-Clamp versus On-Clamp Robotic Partial Nephrectomy: A Multicenter Match-Paired Case-Control Study.

    Science.gov (United States)

    Peyronnet, Benoit; Khene, Zine-Eddine; Pradère, Benjamin; Seisen, Thomas; Verhoest, Grégory; Masson-Lecomte, Alexandra; Grassano, Yohann; Roumiguié, Mathieu; Beauval, Jean-Baptiste; Baumert, Hervé; Droupy, Stéphane; Doumerc, Nicolas; Bernhard, Jean-Christophe; Vaessen, Christophe; Bruyère, Franck; de la Taille, Alexandre; Rouprêt, Morgan; Bensalah, Karim

    2017-01-01

    The aim of this study was to compare the outcomes of on-clamp and off-clamp robotic partial nephrectomy (RPN). The charts of all patients who underwent an RPN at 8 institutions between 2010 and 2014 were retrospectively reviewed. The patients who underwent an off-clamp RPN were matched to on-clamp RPN in a 1-4 fashion according to the following variables: RENAL score, tumor size and surgeon's experience. Pre-, intra-, and postoperative data were compared between both groups. Among 525 RPN, 26 were performed off-clamp (5%). They were matched to 104 on-clamp RPN. The complications rate (15.5 vs. 7.7%, p = 0.53), major complications rate (4.9 vs. 3.9%; p = 0.82), and transfusions rate (0 vs. 4.9%; p = 0.58) did not differ significantly between the clamped and unclamped groups. Conversely, estimated blood loss was higher in the off-clamp group (266.4 vs. 284.6 mL, p = 0.048) and so was the rate of conversion to radical nephrectomy (0 vs. 7.7%, p = 0.04). Postoperative preservation of renal function was comparable in both groups. Off-clamp RPN is feasible for a small subgroup of renal tumors without increased risk of postoperative complications but at the cost of higher estimated blood loss and increased risk of conversion to radical nephrectomy. © 2017 S. Karger AG, Basel.

  6. Emergent management of APC-2 pelvic ring injuries with an anteriorly placed C-clamp.

    Science.gov (United States)

    Richard, Marc J; Tornetta, Paul

    2009-01-01

    Can anteriorly placed pelvic C-clamps be used successfully in the emergent management of APC-2 pelvic fractures? Prospective cohort. Level 1 trauma center. A single-surgeon series of 24 patients with an anteroposterior compression type 2 pelvic fracture. Application of an anteriorly placed pelvic C-clamp within 2 hours of presentation. Response to hypotension, complications related to pin placement, application time, and symphyseal reduction measured on anteroposterior radiograph. Twenty-four patients with a mean age of 29 years (14-58 years) had an APC-2 pelvic fracture diagnosed by an anteroposterior radiograph of the pelvis on presentation. All patients were emergently managed with an anteriorly placed C-clamp applied in the emergency room (10), angiography suite (9), or operating room (5). Eleven patients presented with hypotension (systolic blood pressure elevation of their blood pressure of 23 mm Hg (10-44 mm Hg). The symphyseal separation was reduced from a mean of 4.5 cm (3-9 cm) to pelvic C-clamp can be placed anteriorly as a part of the early management of APC-2 pelvic fractures with a short application time in a variety of patient care areas.

  7. Ultrasonic lateral modulation imaging, speckle reduction, and displacement vector measurements using simple single-beam scanning or plural crossed-beam scanning with new spectra frequency division processing methods

    Directory of Open Access Journals (Sweden)

    Sumi C

    2012-10-01

    Full Text Available Chikayoshi Sumi, Yousuke IshiiDepartment of Information and Communication Sciences, Faculty of Science and Technology, Sophia University, Tokyo, JapanAbstract: The development of effective ultrasonic tissue displacement measurement methods increases the number of possible applications for various tissue displacement and strain measurements. These applications include measurements of spontaneous motions/deformations generated by heart motion; pulsations from phenomena such as blood flow (intracardiac, intravascular, and carotid; heart, blood vessel, and liver motion; and motion from artificial sources such as motions/deformations generated by applying static compression/stretching forces, vibration or acoustic radiation forces (breast and liver. For arbitrary orthogonal coordinate systems obtained using arbitrary transducer types (eg, linear, convex, sector, arc, or radial array types, or single aperture types with a mechanical scan, several lateral modulation (LM methods (eg, scanning with plural crossed or steered beams over a region of interest have been developed that can be used with new echo imaging methods for tissue displacement/deformation measurements. Specifically, by using such beamforming methods, in addition to highly accurate displacement vector and lateral displacement measurements, LM echo imaging with a high lateral carrier frequency and a high lateral resolution has been developed. Another new beamforming method, referred to as “a steering angle (ASTA method,” ie, scanning with a defined steering angle, is also described. In addition to conventional non-steered-beam scanning (ie, a version of ASTA and conventional steered-beam scanning with a variable steering angle (eg, sector, arc, radial scan, a simple, single-beam scanning method also permits the use of LM, which yields an accurate displacement vector measurement with fewer calculations than the original LM methods. This is accomplished by using a previously developed

  8. Reducing blood loss during laparoscopic myomectomy by temporary uterine artery clamping using bulldog clamp

    Directory of Open Access Journals (Sweden)

    Kai-Jo Chiang

    2014-01-01

    Full Text Available Uterine myoma is the most common benign gynecologic tumor worldwide. Mini-invasive surgery has become popular for myomectomy, with advantages over laparotomy. However, reducing blood loss during laparoscopic myomectomy is a major concern for the surgeon because of the limitation in making a quick control bleeding during the operation. Several methods have proved to decrease blood flow, but are not always effective or available. We present a case of uterine myoma with the uterine arteries clamped by bulldog clamps during laparoscopic myomectomy. The myoma was removed successfully with minimal blood loss (<50 ml during the operation. This is an effective, safe, and reliable method for reducing bleeding during laparoscopic myomectomy that does not require ligation of the uterine artery.

  9. The PCNA-RFC families of DNA clamps and clamp loaders.

    Science.gov (United States)

    Majka, Jerzy; Burgers, Peter M J

    2004-01-01

    The proliferating cell nuclear antigen PCNA functions at multiple levels in directing DNA metabolic pathways. Unbound to DNA, PCNA promotes localization of replication factors with a consensus PCNA-binding domain to replication factories. When bound to DNA, PCNA organizes various proteins involved in DNA replication, DNA repair, DNA modification, and chromatin modeling. Its modification by ubiquitin directs the cellular response to DNA damage. The ring-like PCNA homotrimer encircles double-stranded DNA and slides spontaneously across it. Loading of PCNA onto DNA at template-primer junctions is performed in an ATP-dependent process by replication factor C (RFC), a heteropentameric AAA+ protein complex consisting of the Rfc1, Rfc2, Rfc3, Rfc4, and Rfc5 subunits. Loading of yeast PCNA (POL30) is mechanistically distinct from analogous processes in E. coli (beta subunit by the gamma complex) and bacteriophage T4 (gp45 by gp44/62). Multiple stepwise ATP-binding events to RFC are required to load PCNA onto primed DNA. This stepwise mechanism should permit editing of this process at individual steps and allow for divergence of the default process into more specialized modes. Indeed, alternative RFC complexes consisting of the small RFC subunits together with an alternative Rfc1-like subunit have been identified. A complex required for the DNA damage checkpoint contains the Rad24 subunit, a complex required for sister chromatid cohesion contains the Ctf18 subunit, and a complex that aids in genome stability contains the Elg1 subunit. Only the RFC-Rad24 complex has a known associated clamp, a heterotrimeric complex consisting of Rad17, Mec3, and Ddc1. The other putative clamp loaders could either act on clamps yet to be identified or act on the two known clamps.

  10. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path du...

  11. The problem of isotropic rectangular plate with four clamped edges

    Indian Academy of Sciences (India)

    uniformly distributed loads is a problem that has received considerable attention because of its technical importance. ... center deflection function of the fully clamped rectangular plate has three terms where the first one denotes ... An illustrative example is included of uniform load acting on a fully clamped rectangular plate.

  12. Off-clamp robotic partial nephrectomy: Technique and outcome.

    Science.gov (United States)

    Lamoshi, Abdulraouf Y; Salkini, Mohamad W

    2015-01-01

    Robotic partial nephrectomy (RPN) is a technically challenging procedure. Advanced skills are needed to accomplish tumor resection, hemostasis, and renorrhaphy within short ischemia time in RPN. Off-clamp RPN with zero ischemia may decrease the risk of ischemic reperfusion injury to the kidney. However, the off-clamp technique has been associated with an increased risk of blood loss. The purpose of this study was to evaluate the outcome of our modified off-clamp technique utilized in certain RPN cases. A total of 81 patients underwent RPN between September 2009 and July 2013 for renal masses. We studied a subgroup of patients who underwent off-clamp RPN with zero ischemia time. The off-clamp technique was utilized for exophytic, nonhilar tumors that have a base of 2 cm or less. We developed a novel technique to avoid ischemia reperfusion renal injury while minimizing blood loss in certain cases of RPN. Of the 81 cases of RPN, we reviewed and adopted the off-clamp technique in 34 patients (41.98%). Utilizing off-clamp RPN resulted in an average blood loss of 96.29 ml and 1.56 days (range: 1-3 days) of hospital stay and minimal change in serum creatinine. Off-clamp RPN is safe and feasible approach to excise certain kidney tumors. It carries the benefits of RPN and prevents ischemia reperfusion renal injury.

  13. Studying mechanosensitive ion channels with an automated patch clamp

    NARCIS (Netherlands)

    Barthmes, Maria; Jose, Mac Donald F; Birkner, Jan Peter; Brüggemann, Andrea; Wahl-Schott, Christian; Kocer, Armagan

    Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they

  14. Laparoscopic off-clamp partial nephrectomy using soft coagulation.

    Science.gov (United States)

    Hongo, Fumiya; Kawauchi, Akihiro; Ueda, Takashi; Fujihara-Iwata, Atsuko; Nakamura, Terukazu; Naya, Yoshio; Kamoi, Kazumi; Okihara, Koji; Miki, Tsuneharu

    2015-08-01

    To assess the effectiveness of soft coagulation in off-clamp laparoscopic partial nephrectomy. A total of 32 patients with renal tumors underwent laparoscopic partial nephrectomy with off-clamp using soft coagulation between May 2012 and September 2013. Tumor resection was carried out using a combination of bipolar forceps and a ball electrode using the soft coagulation system without hilar clamping. The outcomes of these patients were compared with those of 30 patients treated with hilar clamping. This off-clamp procedure was successfully completed in 31 cases. No significant differences were observed in the mean age (60 vs 61 years), sex (male/female; 25/7 vs 20/10), mean RENAL nephrometry score (5.7 vs 5.8), mean body mass index (24.4 vs 23) or tumor size (15 mm vs 16 mm) between the two groups. No significant differences were noted in positive surgical margins (0 vs 0) or blood loss (104 vs 115 cc) as well. In contrast, a significant difference was noted in the total operative time (278 vs 238 min). Serum creatinine percentage changes at 3 months were 6.4 versus 7.3% in the off-clamp and hilum-clamp groups, respectively, which were not significantly different. Off-clamp laparoscopic partial nephrectomy can be safely carried out by using a soft coagulation technique. © 2015 The Japanese Urological Association.

  15. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path...

  16. A Study of Charged Current Single Charged Pion Productions on Carbon in a Few-GeV Neutrino Beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraide, Katsuki [Kyoto Univ. (Japan)

    2009-01-01

    Understanding single charged pion production via neutrino-nucleus charged current interaction in the neutrino energy region of a few GeV is essential for future neutrino oscillation experiments since this process is a dominant background for vμ → vx oscillation measurements. There are two contributions to this process: single pion production via baryonic resonance (vμN → μ-+) and coherent pion production interacting with the entire nucleus (vμA → μ-+), where N is nucleon in the nucleus and A is the nucleus. The purpose of the study presented in this thesis is a precise measurement of charged current single charged pion productions, resonant and coherent pion productions, with a good final state separation in the neutrino energy region of a few GeV. In this thesis, we focus on the study of charged current coherent pion production from muon neutrinos scattering on carbon, vμ 12C → μ-12+, in the SciBooNE experiment. This is motivated by the fact that without measuring this component first, the precise determination of resonant pion production cross section can not be achieved since the contribution of coherent pion production in the region of small muon scattering angle is not small. Furthermore, the coherent process is particularly interesting because it is deeply rooted in fundamental physics via Adler's partially conserved axial-vector current theorem. We took data from June 2007 until August 2008, in both the neutrino and antineutrino beam. In total, 2.52 x 1020 protons on target were collected. We have performed a search for charged current coherent pion production by using SciBooNE's full neutrino data set, corresponding to 0.99 x 1020 protons on target. No evidence for coherent pion production is observed. We set 90% confidence level upper limits on the cross section ratio

  17. Evaluation of clamp effects on LMFBR piping systems

    International Nuclear Information System (INIS)

    Jones, G.L.

    1980-01-01

    Loop-type liquid metal breeder reactor plants utilize thin-wall piping to mitigate through-wall thermal gradients due to rapid thermal transients. These piping loops require a support system to carry the combined weight of the pipe, coolant and insulation and to provide attachments for seismic restraints. The support system examined here utilizes an insulated pipe clamp designed to minimize the stresses induced in the piping. To determine the effect of these clamps on the pipe wall a non-linear, two-dimensional, finite element model of the clamp, insulation and pipe wall was used to determine the clamp/pipe interface load distributions which were then applied to a three-dimensional, finite element model of the pipe. The two-dimensional interaction model was also utilized to estimate the combined clamp/pipe stiffness

  18. Establishment of euglycemic clamp technique in beagle dogs

    International Nuclear Information System (INIS)

    Dong Lihou; Song Haifeng

    2010-01-01

    Objective: To establish a euglycemic clamp technique in beagle dogs. Methods: The euglycemic clamp technique was applied in healthy beagle dogs and the blood glucose, insulin, C-peptide, insulin and glucagon were monitored during the clamp. Results: The blood glucose was controlled within the basal level. The coefficient of variation was less than 5% during the clamp. The serum insulin concentration finally reached (40.0 ± 3.8) mIU/L stably and a significant inhibition was shown in endogenous insulin by the determination of C-peptide. But there was no significant increase in serum glucagon compared with basal values. Conclusion: Methodology confirmed that the euglycemic clamp technique is successful in beagle dogs and can be applied in the study of pharmacodynamics of insulin preparations. (authors)

  19. TEM investigation of the surface layer structure [111]{sub B2} of the single NiTi crystal modified by the Si-ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Girsova, S. L., E-mail: girs@ispms.tsc.ru; Poletika, T. M., E-mail: poletm@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); Meisner, S. N., E-mail: msn@ispms.tsc.ru; Meisner, L. L., E-mail: llm@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); National Research Tomsk State University, Tomsk, 634050 (Russian Federation)

    2015-10-27

    The study was carried on for the single NiTi crystals subjected to the Si-ion beam implantation. Using the transmission electron microscopy technique (TEM), the surface layer structure [111]{sub B2} was examined for the treated material. The modified near-surface sublayers were found to have different composition. Thus the uppermost sublayer contained mostly oxides; the lower-lying modified sublayer material was in an amorphous state and the thin underlying sublayer had a defect structure.

  20. Multiple adjustable vascular clamp prototype: feasibility study on an experimental model of end-to-side microsurgical vascular anastomosis.

    Science.gov (United States)

    Pereira, A; Ichihara, S; Collon, S; Bodin, F; Gay, A; Facca, S; Liverneaux, P

    2014-12-01

    The aim of this study was to establish the feasibility of microsurgical end-to-side vascular anastomosis with a multiclamp adjustable vascular clamp prototype in an inert experimental model. Our method consisted of performing an end-to-side microsurgical anastomosis with 10/0 suture on a 2-mm diameter segment. In group 1, the end-to-side segment was held in place by a double clamp and a single end clamp. In group 2, the segment was held in place with a single multiclamp adjustable clamp. The average time for performing the anastomosis was shorter in group 2. The average number of sutures was the same in both groups. No leak was found and permeability was always positive in both groups. Our results show that performing end-to-side anastomosis with a multiclamp adjustable vascular clamp is feasible in an inert experimental model. Feasibility in a live animal model has to be demonstrated before clinical use. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Structural single and multiple crack detection in cantilever beams using a hybrid Cuckoo-Nelder-Mead optimization method

    Science.gov (United States)

    Moezi, Seyed Alireza; Zakeri, Ehsan; Zare, Amin

    2018-01-01

    In this study, the number, location and depth of cracks created in several Euler-Bernoulli beams, such as a simple beam and a more complex multi-step beam are investigated. The location and depth of the created cracks are determined using the hybrid Cuckoo-Nelder-Mead Optimization Algorithm (COA-NM) with high accuracy. The natural frequencies of the cracked beams are determined by solving frequency response equations, and performing modal test experiments. Results of COA-NM show a higher accuracy and convergence speed compared with other methods such as GA-NM, PSO-NM, GA, PSO, COA and several previous studies. Amount of calculations performed by COA-NM to achieve this accuracy is much less compared to other methods.

  2. Single mode solid state distributed feedback dye laser fabricated by grey scale electron beam lithography on dye doped SU-8 resist

    DEFF Research Database (Denmark)

    Balslev, Søren; Rasmussen, Torben; Shi, Peixiong

    2005-01-01

    are optically pumped at 532 nm, and exhibit low lasing threshold from 530 nJ/mm2 and single mode output at selectable wavelengths from 580 to 630 nm, determined by the grating pitch. The lasers are well suited for integration into polymer based lab-on-chip circuits for interference based sensing.......We demonstrate grey scale electron beam lithography on functionalized SU-8 resist for fabrication of single mode solid state dye laser devices. The resist is doped with Rhodamine 6G perchlorate and the lasers are based on a first order Bragg grating distributed feedback resonator. The lasers...

  3. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  4. Large variation finite element method for beams with stochastic stiffness

    CERN Document Server

    Rollot, O

    2003-01-01

    The behavior of beams with stochastic stiffness subjected to either deterministic or stochastic loading is studied via finite element method. The results are contrasted with exact solution to check the accuracy of the FEM for the case of large variations. It represents a generalization of the previous study in which the stiffness matrix was decomposed as a product of three matrices, two of which are numerical ones and the third matrix involves the uncertain stiffness analytically. To illustrate the proposed method, we evaluate the mean and the auto-correlation functions of the displacement of beams under various boundary conditions. Two statically determinate beams (clamped-free or simply-supported) and two statically indeterminate beams (clamped-simply-supported or clamped are both ends) are investigated in this study. The beams are subjected to a deterministic uniform pressure or a stochastic excitation.

  5. Large variation finite element method for beams with stochastic stiffness

    International Nuclear Information System (INIS)

    Rollot, Olivier; Elishakoff, Isaac

    2003-01-01

    The behavior of beams with stochastic stiffness subjected to either deterministic or stochastic loading is studied via finite element method. The results are contrasted with exact solution to check the accuracy of the FEM for the case of large variations. It represents a generalization of the previous study in which the stiffness matrix was decomposed as a product of three matrices, two of which are numerical ones and the third matrix involves the uncertain stiffness analytically. To illustrate the proposed method, we evaluate the mean and the auto-correlation functions of the displacement of beams under various boundary conditions. Two statically determinate beams (clamped-free or simply-supported) and two statically indeterminate beams (clamped-simply-supported or clamped are both ends) are investigated in this study. The beams are subjected to a deterministic uniform pressure or a stochastic excitation

  6. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  7. Characterization of potassium channel modulators with QPatch automated patch-clamp technology: system characteristics and performance

    DEFF Research Database (Denmark)

    Kutchinsky, Jonatan; Friis, Søren; Asmild, Margit

    2003-01-01

    developed using this technology. A single-channel prototype of the QPatch system was used for validation of the patch-clamp chip technology. We present here data on the quality of patch-clamp recordings and from actual drug screening studies of human potassium channels expressed in cultured cell lines....... Using Chinese hamster ovary (CHO) and human embryonic kidney cells (HEK), gigaseals of 4.1 +/- 0.4 GOmega (n = 146) and high-quality whole-cell current recordings were obtained from hERG and KCNQ4 potassium channels. Success rates for gigaseal recordings varied from 40 to 95%, and 67% of the whole......-response relationship characterizations of verapamil and rBeKm-1 blockage of hERG currents provided IC(50) values similar to values reported in the literature....

  8. Multi-mode excitation of a clamped–clamped microbeam resonator

    KAUST Repository

    Younis, Mohammad I.

    2015-02-18

    We present modeling and simulation of the nonlinear dynamics of a microresonator subjected to two-source electrostatic excitation. The resonator is composed of a clamped–clamped beam excited by a DC voltage load superimposed to two AC voltage loads of different frequencies. One frequency is tuned close to the first natural frequency of the beam and the other is close to the third (second symmetric) natural frequency. A multi-mode Galerkin procedure is applied to extract a reduced-order model, which forms the basis of the numerical simulations. Time history response, Poincare’ sections, Fast Fourier Transforms FFT, and bifurcation diagrams are used to reveal the dynamics of the system. The results indicate complex nonlinear phenomena, which include quasiperiodic motion, torus bifurcations, and modulated chaotic attractors.

  9. Enhanced chromatin accessibility of the dosage compensated Drosophila male X-chromosome requires the CLAMP zinc finger protein.

    Science.gov (United States)

    Urban, Jennifer; Kuzu, Guray; Bowman, Sarah; Scruggs, Benjamin; Henriques, Telmo; Kingston, Robert; Adelman, Karen; Tolstorukov, Michael; Larschan, Erica

    2017-01-01

    The essential process of dosage compensation is required to equalize gene expression of X-chromosome genes between males (XY) and females (XX). In Drosophila, the conserved Male-specific lethal (MSL) histone acetyltransferase complex mediates dosage compensation by increasing transcript levels from genes on the single male X-chromosome approximately two-fold. Consistent with its increased levels of transcription, the male X-chromosome has enhanced chromatin accessibility, distinguishing it from the autosomes. Here, we demonstrate that the non-sex-specific CLAMP (Chromatin-linked adaptor for MSL proteins) zinc finger protein that recognizes GA-rich sequences genome-wide promotes the specialized chromatin environment on the male X-chromosome and can act over long genomic distances (~14 kb). Although MSL complex is required for increasing transcript levels of X-linked genes, it is not required for enhancing global male X-chromosome chromatin accessibility, and instead works cooperatively with CLAMP to facilitate an accessible chromatin configuration at its sites of highest occupancy. Furthermore, CLAMP regulates chromatin structure at strong MSL complex binding sites through promoting recruitment of the Nucleosome Remodeling Factor (NURF) complex. In contrast to the X-chromosome, CLAMP regulates chromatin and gene expression on autosomes through a distinct mechanism that does not involve NURF recruitment. Overall, our results support a model where synergy between a non-sex-specific transcription factor (CLAMP) and a sex-specific cofactor (MSL) creates a specialized chromatin domain on the male X-chromosome.

  10. Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies

    Directory of Open Access Journals (Sweden)

    Xue Dong

    2013-01-01

    Full Text Available Excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination are the two bottlenecks of cone-beam CT (CBCT imaging. Compressed sensing (CS reconstruction algorithms show promises in recovering faithful signals from low-dose projection data but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter can be accurately measured and removed using measurement-based methods. However, these approaches are considered unpractical in the conventional FDK reconstruction, due to the inevitable primary loss for scatter measurement. We combine measurement-based scatter correction and CS-based iterative reconstruction to generate scatter-free images from low-dose projections. We distribute blocked areas on the detector where primary signals are considered redundant in a full scan. Scatter distribution is estimated by interpolating/extrapolating measured scatter samples inside blocked areas. CS-based iterative reconstruction is finally carried out on the undersampled data to obtain scatter-free and low-dose CBCT images. With only 25% of conventional full-scan dose, our method reduces the average CT number error from 250 HU to 24 HU and increases the contrast by a factor of 2.1 on Catphan 600 phantom. On an anthropomorphic head phantom, the average CT number error is reduced from 224 HU to 10 HU in the central uniform area.

  11. In situ beam analysis of radiation damage kinetics in MgTiO3 single crystals at 170-470 K

    International Nuclear Information System (INIS)

    Yu, Ning; Mitchell, J.N.; Sickafus, K.E.; Nastasi, M.

    1995-01-01

    Radiation damage kinetics in synthetic MgTiO 3 (geikielite) single crystals have been studied using the in situ ion beam facility at Los Alamos National Laboratory. The geikielite samples were irradiated at temperatures of 170, 300, and 470 K with 400 keV xenon ions and the radiation damage was sequentially measured with Rutherford backscattering using a 2 MeV He ion beam along a channeling direction. Threshold doses of I and 5x l0 15 Xe/cm 2 were determined for the crystalline-to-amorphous transformation induced by Xe ion irradiation at 170 and 300 K, respectively. However, geikielite retained its crystallinity up to a dose of 2.5xl0 16 Xe/cm 2 at the irradiation temperature of 470 K. This study has shown that MgTiO 3 , which has a corundum derivative structure, is another radiation resistant material that has the potential for use in radiation environments

  12. An ultra-fast EOD-based force-clamp detects rapid biomechanical transitions

    Science.gov (United States)

    Woody, Michael S.; Capitanio, Marco; Ostap, E. Michael; Goldman, Yale E.

    2017-08-01

    We assembled an ultra-fast infrared optical trapping system to detect mechanical events that occur less than a millisecond after a ligand binds to its filamentous substrate, such as myosin undergoing its 5 - 10 nm working stroke after actin binding. The instrument is based on the concept of Capitanio et al.1, in which a polymer bead-actin-bead dumbbell is held in two force-clamped optical traps. A force applied by the traps causes the filament to move at a constant velocity as hydrodynamic drag balances the applied load. When the ligand binds, the filament motion stops within 100 μs as the total force from the optical traps is transferred to the attachment. Subsequent translations signal active motions, such as the magnitude and timing of the motor's working stroke. In our instrument, the beads defining the dumbbell are held in independent force clamps utilizing a field-programmable gate array (FPGA) to update the trap beam positions at 250 kHz. We found that in our setup, acousto-optical deflectors (AODs) steering the beams were unsuitable for this purpose due to a slightly non-linear response in the beam intensity and deflection angle vs. the AOD ultra-sound wavelength, likely caused by low-amplitude standing acoustic waves in the deflectors. These aberrations caused instability in the force feedback loops leading to artefactual 20 nm jumps in position. This type of AOD non-linearity has been reported to be absent in electro-optical deflectors (EODs)2. We demonstrate that replacement of the AODs with EODs improves the performance of our instrument. Combining the superior beam-steering capability of the EODs, force acquisition via back-plane interferometry, and the dual high-speed FPGA-based feedback loops, we smoothly and precisely apply constant loads to study the dynamics of interactions between biological molecules such as actin and myosin.

  13. Investigation of the Effect of Material on Undamped Free Vibration of Cantilever Beams with Uniform Single Surface Crack

    Science.gov (United States)

    Mufazzal, Sameera; Muzakkir, S. M.; Zakir Jafri, Hasan

    2017-08-01

    Crack detection in structures is a critical area of research where the developments have been made out since decades. Various techniques are available for early identification and quantification of cracks to predict and prevent the unexpected sudden failure of structure and ensure uninterrupted service. Use of vibration analysis for detecting crack is one of the widely used techniques which offer lots of advantages over other like it is easier and less costly method and can be used for inaccessible components. The present work attempts to use modal analysis through FEA to investigate the effect of crack on natural frequency of vibration in beams of different materials, for three different crack location. From the result, it has been inferred that among Structural Steel (SS), Aluminium alloy (Al) and Gray Cast Iron (CI), the natural frequency is highest for Al beam and lowest for CI beam. Introduction of crack reduces the natural frequency of vibration, however, the effect of crack location on frequency is not uniform for different modes. Also, the trend is similar in beams of all the materials.

  14. Optimizing the e-beam profile of a single carbon nanotube field emission device for electric propulsion systems

    Directory of Open Access Journals (Sweden)

    Juliano Fujioka Mologni

    2010-04-01

    Full Text Available Preliminary studies on field emission (FE arrays comprised of carbon nanotubes (CNT as an electron source for electric propulsion system show remarkably promising results. Design parameters for a carbon nanotube (CNT field-emission device operating on triode configuration were numerically simulated and optimized in order to enhance the e-beam focusing quality. An additional focus gate (FG was integrated to the device to control the profile of the emitted e-beam. An axisymmetric finite element model was developed to calculate the electric field distribution on the vacuum region and a modified Fowler-Nordheim (FN equation was used to evaluate the current density emission and the effective emitter area. Afterward, a FE simulation was employed in order to calculate the trajectory of the emitted electrons and define the electron-optical properties of the e-beam. The integration of the FG was fully investigated via computational intelligence techniques. The best performance device according to our simulations presents a collimated e-beam profile that suits well for field emission displays, magnetic field detection and electron microscopy. The automated computational design tool presented in this study strongly benefits the robust design of integrated electron-optical systems for vacuum field emission applications, including electrodynamic tethering and electric propulsion systems.

  15. A Feasibility Study of Low-Dose Single-Scan Dual-Energy Cone-Beam CT in Many-View Under-Sampling Framework.

    Science.gov (United States)

    Lee, Donghyeon; Lee, Jiseoc; Kim, Hyoyi; Lee, Taewon; Soh, Jeongtae; Park, Miran; Kim, Changhwan; Lee, Yeon Ju; Cho, Seungryong

    2017-12-01

    A single-scan dual-energy low-dose cone-beam CT (CBCT) imaging technique that exploits a multi-slit filter is proposed in this paper. The multi-slit filter installed between the x-ray source and the scanned object is reciprocated during a scan. The x-ray beams through the slits would generate relatively low-energy x-ray projection data, while the filtered beams would make high-energy projection data. An iterative image reconstruction algorithm that uses an adaptive-steepest-descent method to minimize image total-variation under the constraint of data fidelity was applied to reconstructing the image from the low-energy projection data. Since the high-energy projection data suffer from a substantially high noise level due to the beam filtration, we have developed a new algorithm that exploits the joint sparsity between the low- and high-energy CT images for image reconstruction of the high-energy CT image. The proposed image reconstruction algorithm uses a gradient magnitude image (GMI) of the low-energy CT image by regularizing the difference of GMIs of the low- and high-energy CT images to be minimized. The feasibility of the proposed technique has been demonstrated by the use of various phantoms in the experimental CBCT setup. Furthermore, based on the proposed dual-energy imaging, a material differentiation was performed and its potential utility has been shown. The proposed imaging technique produced promising results for its potential application to a low-dose single-scan dual-energy CBCT.

  16. Dynamic clamp: a powerful tool in cardiac electrophysiology

    NARCIS (Netherlands)

    Wilders, Ronald

    2006-01-01

    Dynamic clamp is a collection of closely related techniques that have been employed in cardiac electrophysiology to provide direct answers to numerous research questions regarding basic cellular mechanisms of action potential formation, action potential transfer and action potential synchronization

  17. The Drosophila CLAMP protein associates with diverse proteins on chromatin.

    Science.gov (United States)

    Urban, Jennifer A; Urban, John M; Kuzu, Guray; Larschan, Erica N

    2017-01-01

    Gaining new insights into gene regulation involves an in-depth understanding of protein-protein interactions on chromatin. A powerful model for studying mechanisms of gene regulation is dosage compensation, a process that targets the X-chromosome to equalize gene expression between XY males and XX females. We previously identified a zinc finger protein in Drosophila melanogaster that plays a sex-specific role in targeting the Male-specific lethal (MSL) dosage compensation complex to the male X-chromosome, called the Chromatin-Linked Adapter for MSL Proteins (CLAMP). More recently, we established that CLAMP has non-sex-specific roles as an essential protein that regulates chromatin accessibility at promoters genome-wide. To identify associations between CLAMP and other factors in both male and female cells, we used two complementary mass spectrometry approaches. We demonstrate that CLAMP associates with the transcriptional regulator complex Negative Elongation Factor (NELF) in both sexes and determine that CLAMP reduces NELF recruitment to several target genes. In sum, we have identified many new CLAMP-associated factors and provide a resource for further study of this little understood essential protein.

  18. Force-controlled patch clamp of beating cardiac cells.

    Science.gov (United States)

    Ossola, Dario; Amarouch, Mohamed-Yassine; Behr, Pascal; Vörös, János; Abriel, Hugues; Zambelli, Tomaso

    2015-03-11

    From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.

  19. Modelling methods in stress analysis of pipe coupling clamps

    International Nuclear Information System (INIS)

    Dutta, B.K.; Kushwaha, H.S.; Kakodkar, A.

    1987-01-01

    Pipe coupling using clamps are becoming more and more popular components in nuclear power plants and are used in place of conventional flanges because of their compactness, easy maintenance and more reliability. They are used in large numbers in Pressurised Heavy Water Reactors (PHWR) such as at the joint between feeder pipe and end-fitting, in F/M housing etc. Integrity of these clamps have direct effect on overall safety of the nuclear power plants. This necessitates proper design, fabrication, installation and maintenance of these components. Proper design of these clamps is a challenge to the designer. This is because of changing boundary conditions at the interface with the hub during various stages of loading. A detail stress analysis of clamps considering changing boundary conditions under various loadings can be done using finite element technique. In the following sections, two finite element modelling methods to simulate clamps along with hubs are described. Both these methods assumed absence of friction between the clamp and hubs during bolting, whereas absence of relative movement between them was assumed during other stages of loadings. (orig.)

  20. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  1. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

    Science.gov (United States)

    Polglase, Graeme R; Dawson, Jennifer A; Kluckow, Martin; Gill, Andrew W; Davis, Peter G; Te Pas, Arjan B; Crossley, Kelly J; McDougall, Annie; Wallace, Euan M; Hooper, Stuart B

    2015-01-01

    As measurement of arterial oxygen saturation (SpO2) is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known. We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs. Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2) were measured continuously in apnoeic preterm lambs (126±1 day gestation). Positive pressure ventilation was initiated either 1) prior to umbilical cord clamping, or 2) after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping. Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping. The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  2. Clamp and clamp loader structures of the human checkpoint protein complexes, Rad9-1-1 and Rad17-RFC.

    Science.gov (United States)

    Shiomi, Yasushi; Shinozaki, Ayako; Nakada, Daisuke; Sugimoto, Katsunori; Usukura, Jiro; Obuse, Chikashi; Tsurimoto, Toshiki

    2002-08-01

    We have reported that protein imaging by transmission electron microscope observation based on low-angle platinum shadowing can reproduce characteristic ring structures of the replication clamp, proliferating cell nuclear antigen (PCNA), and the clamp loader protein, replication factor C (RFC). The checkpoint protein complexes, Rad9-Hus1-Rad1 (Rad9-1-1) and Rad17-RFCs2-5 (Rad17-RFC), have been predicted to function as novel clamp and clamp loader proteins, respectively, due to their amino acid sequence similarities with PCNA and RFC. We reconstituted human Rad9-1-1 and Rad17-RFC complexes in insect cells using a baculovirus expression system and showed purified Rad9-1-1 to be composed of equimolar amounts of Rad9, Hus1 and Rad1 proteins, exhibiting a native molecular mass of 100 kDa, in line with a trimeric complex. When Rad17 was co-expressed with the four small subunits of RFC in insect cells, these proteins formed a complex of 240 kDa that displayed DNA binding, ATPase activity and binding to its predicted target protein, Rad9-1-1. Analyses of the molecular architecture of Rad9-1-1 and Rad17-RFC using transmission electron microscopy, in comparison with PCNA and RFC, revealed the Rad9-1-1 complex to have a characteristic ring structure indistinguishable from that of PCNA in shape and size. In addition, the Rad17-RFC complex was found to be oval in structure and 26 x 22 nm in size with a cleft, reminiscent of the structure of RFC. Our direct comparison of images from the two sets of clamp and clamp loader proteins indicated that Rad9-1-1 and Rad17-RFC are, respectively, structural orthologs of PCNA and RFC, with presumed functions as novel clamp and clamp-loader proteins in eukaryotes.

  3. Analysis of sub-bandgap losses in TiO2 coating deposited via single and dual ion beam deposition

    Czech Academy of Sciences Publication Activity Database

    Žídek, Karel; Hlubuček, Jiří; Horodyská, Petra; Budasz, Jiří; Václavík, Jan

    2017-01-01

    Roč. 626, March (2017), s. 60-65 ISSN 0040-6090 R&D Projects: GA MŠk(CZ) LO1206 Institutional support: RVO:61389021 Keywords : Ion beam deposition * Titanium dioxide * Optical coating * Sub-bandgap losses * Urbach tail Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.879, year: 2016 http://www.sciencedirect.com/science/article/pii/S0040609017301256

  4. External mean flow influence on sound transmission through finite clamped double-wall sandwich panels

    Science.gov (United States)

    Liu, Yu; Catalan, Jean-Cédric

    2017-09-01

    This paper studies the influence of an external mean flow on the sound transmission through finite clamped double-wall sandwich panels lined with poroelastic materials. Biot's theory is employed to describe wave propagation in poroelastic materials and various configurations of coupling the poroelastic layer to the facing plates are considered. The clamped boundary of finite panels are dealt with by the modal superposition theory and the weighted residual (Garlekin) method, leading to a matrix equation solution for the sound transmission loss (STL) through the structure. The theoretical model is validated against existing theories of infinite sandwich panels with and without an external flow. The numerical results of a single incident wave show that the external mean flow has significant effects on the STL which are coupled with the clamped boundary effect dominating in the low-frequency range. The external mean flow also influences considerably the limiting incidence angle of the panel system and the effect of the incidence angle on the STL. However, the influences of the azimuthal angle and the external flow orientation are negligible.

  5. A new clamp method for firing bricks | Obeng | Journal of Applied ...

    African Journals Online (AJOL)

    A new clamp method for firing bricks. ... Journal of Applied Science and Technology ... To overcome this operational deficiencies, a new method of firing bricks that uses brick clamp technique that incorporates a clamp wall of 60 cm thickness, a six tier approach of sealing the top of the clamp (by combination of green bricks) ...

  6. Dynamic clamp as a tool to study the functional effects of individual membrane currents

    NARCIS (Netherlands)

    Berecki, Géza; Verkerk, Arie O.; van Ginneken, Antoni C. G.; Wilders, Ronald

    2014-01-01

    Today, the patch-clamp technique is the main technique in electrophysiology to record action potentials or membrane current from isolated cells, using a patch pipette to gain electrical access to the cell. The common recording modes of the patch-clamp technique are current clamp and voltage clamp.

  7. Measuring beta-cell function relative to insulin sensitivity in youth: Does the hyperglycemic clamp suffice?

    Science.gov (United States)

    To compare beta-cell function relative to insulin sensitivity, disposition index (DI), calculated from two clamps (2cDI, insulin sensitivity from the hyperinsulinemic-euglycemic clamp and first-phase insulin from the hyperglycemic clamp) with the DI calculated from the hyperglycemic clamp alone (hcD...

  8. Impact of Individual Proliferating Cell Nuclear Antigen-DNA Contacts on Clamp Loading and Function on DNA*

    Science.gov (United States)

    Zhou, Yayan; Hingorani, Manju M.

    2012-01-01

    Ring-shaped clamp proteins encircle DNA and affect the work of many proteins, notably processive replication by DNA polymerases. Crystal structures of clamps show several cationic residues inside the ring, and in a co-crystal of Escherichia coli β clamp-DNA, they directly contact the tilted duplex passing through (Georgescu, R. E., Kim, S. S., Yurieva, O., Kuriyan, J., Kong, X. P., and O'Donnell, M. (2008) Structure of a sliding clamp on DNA. Cell 132, 43–54). To investigate the role of these contacts in reactions involving circular clamps, we examined single arginine/lysine mutants of Saccharomyces cerevisiae proliferating cell nuclear antigen (PCNA) in replication factor C (RFC)-catalyzed loading of the clamp onto primer template DNA (ptDNA). Previous kinetic analysis has shown that ptDNA entry inside an ATP-activated RFC-PCNA complex accelerates clamp opening and ATP hydrolysis, which is followed by slow PCNA closure around DNA and product dissociation. Here we directly measured multiple steps in the reaction (PCNA opening, ptDNA binding, PCNA closure, phosphate release, and complex dissociation) to determine whether mutation of PCNA residues Arg-14, Lys-20, Arg-80, Lys-146, Arg-149, or Lys-217 to alanine affects the reaction mechanism. Contrary to earlier steady state analysis of these mutants (McNally, R., Bowman, G. D., Goedken, E. R., O'Donnell, M., and Kuriyan, J. (2010) Analysis of the role of PCNA-DNA contacts during clamp loading. BMC Struct. Biol. 10, 3), our pre-steady state data show that loss of single cationic residues can alter the rates of all DNA-linked steps in the reaction, as well as movement of PCNA on DNA. These results explain an earlier finding that individual arginines and lysines inside human PCNA are essential for polymerase δ processivity (Fukuda, K., Morioka, H., Imajou, S., Ikeda, S., Ohtsuka, E., and Tsurimoto, T. (1995) Structure-function relationship of the eukaryotic DNA replication factor, proliferating cell nuclear antigen

  9. Full-range stress intensity factor solutions for clamped SENT specimens

    International Nuclear Information System (INIS)

    Zhu, Xian-Kui

    2017-01-01

    Single edge notched tension (SENT) specimen with clamped ends has been receiving increasing attention worldwide as a low-constraint specimen to measure less-conservative fracture toughness of pipeline steels in the oil and gas industry. Several SENT test methods were developed, but the solutions of stress intensity factor K used are different. The existing K solutions are thus reviewed and evaluated in this paper for the clamped SENT specimens, and then a full-range analytical solution of K is developed as a function of full-range crack sizes (a/W) and specimen aspect ratios (H/W). From this result, a simple closed-form solution of K is obtained particularly for H/W = 10, as used by the current SENT toughness test methods. The proposed full-range K solutions are validated using different numerical results and error analyses, and thus can be used generally to meet the needs of different SENT testing for determination of fatigue crack growth rate or fracture toughness in the low-constraint conditions. - Highlights: • The stress intensity factor K solutions were reinvestigated for clamped SENT specimens. • A general, full-range analytical solution of K was obtained for H/W≥3 with accuracy of 0.25%. • The corrected K solution obtained previously for BS 8571 was shown accurate for crack sizes of a/W≤0.925. • The actual valid ranges of three FEA results of K were redefined. • A simple closed-form solution of K was proposed for clamped SENT specimens with H/W = 10.

  10. SU-F-T-643: Feasibility of Performing Patient Specific VMAT QA On Single Linac for Plans Treated in Beam-Matched Elekta Agility Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Leung, R; Lee, V; Cheung, S; Lee, K; Law, G; Wong, M; Chan, M; Mun, Tuen [Hospital, Hong Kong (Hong Kong)

    2016-06-15

    Purpose: The increasing application of VMAT demands a more efficient workflow and QA solution. This study aims to investigate the feasibility of performing VMAT QA measurements on one linac for plans treated on other beam-matched Elekta Agility linacs. Methods: A single model was used to create 24 clinically approved VMAT plans (12 head-and-neck and 12 prostate using 6MV and 10MV respectively) on Pinnacle v9.10 (Philips, Einhoven, Netherlands). All head-and-neck plans were delivered on three beam-matched machines while all prostate cases were delivered on two beam-matched 10MV Agility machines. All plans were delivered onto PTW Octavius 4D phantom with 1500 detector array (PTW, Freiburg, Germany). Reconstructed volume doses were then compared with the Pinnacle reference plans in Verisoft 6.1 under 3%/3mm gamma criteria at local dose. Plans were considered clinically acceptable if >90% of the voxels passing the gamma criteria. Results: All measurements were passed (3D gamma passing rate >90%) and the result shows that the mean difference of 3D gamma of 12 head-and-neck cases is 1.2% with standard deviation of 0.6%. While for prostate cases, the mean difference of 3D gamma is 0.9% with standard deviation of 0.7%. Maximum difference of 3D gamma of all measurements between beam-matched machines is less than 2.5%. The differences of passing rates between different machines were statistically insignificant (p>0.05). Conclusion. The result suggests that ther Conclusion: The result suggests that there exists a 3D gamma threshold, in our case 92.5%, above which the VMAT QA performed in any one of beam-matched machine will also pass in another one. Therefore, VMAT QA efficiency may be increased and phantom set up time can be saved by implementing such method. A constant performance across all beam matched machines must be maintained to make this QA approach feasible.

  11. Creation of domains by direct electron beam writing in magnesium-doped LiNbO{sub 3} and LiNbO{sub 3}:Fe single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Palatnikov, M.N. [Institute of Chemistry and Technology of Rare Elements and Mineral Raw Materials, 26a Akademgorodok, Apatity, Murmansk 184209 (Russian Federation); Kokhanchik, L.S.; Emelin, E.V. [Institute of Microelectronics Technology and High Purity Materials of Russian Academy of Sciences, 6 Academician Ossipyan st, Chernogolovka, Moscow 142432 (Russian Federation); Sidorov, N.V. [Institute of Chemistry and Technology of Rare Elements and Mineral Raw Materials, 26a Akademgorodok, Apatity, Murmansk 184209 (Russian Federation); Manukovskaya, D.V., E-mail: deenka@yandex.ru [Institute of Chemistry and Technology of Rare Elements and Mineral Raw Materials, 26a Akademgorodok, Apatity, Murmansk 184209 (Russian Federation)

    2016-03-01

    Highlights: • The periodic domains are created in crystal LiNbO{sub 3}:Mg by direct electron beam writing. • Periodic domains appear only at equilibrium between switching and screening times. • Equilibrium exists in crystal co-doped by Fe. • Shape and appearance of domains depend on the conductivity type. - Abstract: Domain structures in the Z-cut of highly doped LiNbO{sub 3}:Mg and LiNbO{sub 3}:Mg,Fe single crystals were created by direct electron beam writing (DEBW). It was found that the value and type of electron conductivity influence the shape and number of domains thus created. Controlled electron beam regular domains were created only in samples of the crystal LiNbO{sub 3}:Mg,Fe [MgO] = 5.16 mol.%, [Fe] = 0.007 mol.%. In highly doped LiNbO{sub 3}:Mg ([MgO] = 5.19 mol.%) crystal, the domains were formed chaotically and controlled creation of domains did not occur. The domain shapes were analyzed in the framework of the theory of screening of domain nuclei depolarizing electric fields and the influence of screening on the final shape of domains. It was found that screening of intrinsic electric fields is faster in the LiNbO{sub 3}:Mg,Fe crystal. This crystal has a high electronic conductivity of hopping type with a high mobility of charge carriers. Thus, a small amount of Fe provides equilibrium between the ferroelectric switching velocity and screening of the depolarizing electric field velocity. The results are discussed considering differences in the electron conductivity mechanisms, which control the screening of depolarizing electric field velocity and spatial charge area formed under an electron beam.

  12. Influence of squeeze film damping on the higher-order modes of clamped–clamped microbeams

    International Nuclear Information System (INIS)

    Alcheikh, N; Kosuru, L; Jaber, N; Bellaredj, M; Younis, M I

    2016-01-01

    This paper presents an experimental study and a finite-element analysis of the effect of squeeze film damping on the resonance frequency and quality factor of the higher-order flexure vibrations modes of clamped–clamped microbeams. Viscoelastic and silicon nitride microbeams are fabricated and are electrostatically actuated by various electrode configurations to trigger the first, second, and third modes. The damping characteristic and the resonance frequency of these modes are examined for a wide range of gas pressure and electrostatic voltage loads. The results of the silicon nitride beams and viscoelastic beams are compared. It is found that the intrinsic material loss is the major dissipation mechanism at low pressure for the viscoelastic microbeams, significantly limiting their quality factor. It is also found that while the silicon nitride beams show higher quality factors at the intrinsic and molecular regimes of pressure, due to their low intrinsic loss, their quality factors near atmospheric pressure are lower than those of the viscoelastic microbeams. Further, the higher-order modes of all the beams show much higher quality factors at atmospheric pressure compared to the first mode, which could be promising for operating such resonators in air. Experimental results and finite element model simulations show good agreement for resonance frequency and quality factor for the three studied modes. (paper)

  13. Development of a silicon microstrip detector with single photon sensitivity for fast dynamic diffraction experiments at a synchrotron radiation beam

    Science.gov (United States)

    Arakcheev, A.; Aulchenko, V.; Kudashkin, D.; Shekhtman, L.; Tolochko, B.; Zhulanov, V.

    2017-06-01

    Time-resolved experiments on the diffraction of synchrotron radiation (SR) from crystalline materials provide information on the evolution of a material structure after a heat, electron beam or plasma interaction with a sample under study. Changes in the material structure happen within a microsecond scale and a detector with corresponding parameters is needed. The SR channel 8 of the VEPP-4M storage ring provides radiation from the 7-pole wiggler that allows to reach several tens photons within one μs from a tungsten crystal for the most intensive diffraction peak. In order to perform experiments that allow to measure the evolution of tungsten crystalline structure under the impact of powerful laser beam, a new detector is developed, that can provide information about the distribution of a scattered SR flux in space and its evolution in time at a microsecond scale. The detector is based on the silicon p-in-n microstrip sensor with DC-coupled metal strips. The sensor contains 1024 30 mm long strips with a 50 μm pitch. 64 strips are bonded to the front-end electronics based on APC128 ASICs. The APC128 ASIC contains 128 channels that consist of a low noise integrator with 32 analogue memory cells each. The integrator equivalent noise charge is about 2000 electrons and thus the signal from individual photons with energy above 40 keV can be observed. The signal can be stored at the analogue memory with 10 MHz rate. The first measurements with the beam scattered from a tungsten crystal with energy near 60 keV demonstrated the capability of this prototype to observe the spatial distribution of the photon flux with the intensity from below one photon per channel up to 0~10 photons per channel with a frame rate from 10 kHz up to 1 MHz.

  14. Molecular beam study of the mechanism of catalyzed hydrogen--deuterium exchange on platinum single crystal surfaces

    International Nuclear Information System (INIS)

    Bernasek, S.L.; Somorjai, G.A.

    1975-01-01

    The hydrogen--deuterium exchange reaction was studied by molecular beam scattering on low and high Miller index crystal faces of platinum in the surface temperature range of 300--1300degreeK. Under the condition of the experiments which put strict limitation on the residence time of the detected molecules, the reaction product, HD, was readily detectable from the high Miller index, stepped surfaces (integrated reaction probability, defined as total desorbed HD flux divided by D 2 flux, is approx.10/sup -1/) while HD formation was below the limit of detectability on the Pt(111) low Miller index surface (reaction probability 2 beam pressure and half-order in H 2 background pressure. The absence of beam kinetic energy dependence of the rate indicates that the molecular adsorption does not require activation energy. The surface is able to store a sufficiently large concentration of atoms which react with the molecules by a two-branch mechanism. The rate constants for this two-branch mechanism were determined under conditions of constant H atom coverage, reducing the bimolecular reaction to a pseudo-first-order reaction. At lower temperatures ( 1 = (2plus-or-minus1) times10 5 exp(-4.5plus-or-minus0.5 kcal/RT) sec/sup -1/. The rate determining step appears to be the diffusion of the D 2 molecule on the surface to a step site where HD is formed via a three-center (atom--molecule) reaction, or via a two-center (atom--atom) reaction subsequent to D 2 dissociation at the step. At higher temperatures (>600degreeK) the reaction between an adsorbed H atom and an incident D 2 gas molecule competes with the low temperature branch. The rate constant for this branch is k 2 = (1plus-or-minus2) times10 2 exp(-0.6plus-or-minus0.3 kcal/RT) sec/sup -1/

  15. Full characterization of laser-accelerated ion beams using Faraday cup, silicon carbide, and single-crystal diamond detectors

    Czech Academy of Sciences Publication Activity Database

    Margarone, Daniele; Krása, Josef; Giuffrida, L.; Picciotto, A.; Torrisi, L.; Nowak, T.; Musumeci, P.; Velyhan, Andriy; Prokůpek, Jan; Láska, Leoš; Mocek, Tomáš; Ullschmied, Jiří; Rus, Bedřich

    2011-01-01

    Roč. 109, č. 10 (2011), "103302-1"-"103302-8" ISSN 0021-8979 R&D Projects: GA ČR(CZ) GAP205/11/1165; GA MŠk(CZ) 7E09092 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : aluminium * chemical sensors * diamond * electrostatics * iodine * ion beams * thin films * lasers * time of flight spectrometers Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.168, year: 2011 http://jap.aip.org/ resource /1/japiau/v109/i10/p103302_s1

  16. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Laird, J.S.; Bardos, R.A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T.; Sekiguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan).

    1993-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  17. Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection

    Science.gov (United States)

    Li, Yinsheng; Garrett, John W.; Li, Ke; Wu, Yijing; Johnson, Kevin; Schafer, Sebastian; Strother, Charles; Chen, Guang-Hong

    2018-04-01

    Time-resolved C-arm cone-beam CT (CBCT) angiography (TR-CBCTA) images can be generated from a series of CBCT acquisitions that satisfy data sufficiency condition in analytical image reconstruction theory. In this work, a new technique was developed to generate TR-CBCTA images from a single short-scan CBCT data acquisition with contrast media injection. The reconstruction technique enabling this application is a previously developed image reconstruction technique, synchronized multi-artifact reduction with tomographic reconstruction (SMART-RECON). In this new application, the acquired short-scan CBCT projection data were sorted into a union of several sub-sectors of view angles and each sub-sector of view angles corresponds to an individual image volume to be reconstructed. The SMART-RECON method was then used to jointly reconstruct all of these individual image volumes under two constraints: (1) each individual image volume is maximally consistent with the measured cone-beam projection data within the corresponding view angle sector and (2) the nuclear norm of the image matrix is minimized. The difference between these reconstructed individual image volumes is used to generated the desired subtracted angiograms. To validate the technique, numerical simulation data generated from a fractal tree angiogram phantom were used to quantitatively study the accuracy of the proposed method and retrospective in vivo human subject studies were used to demonstrate the feasibility of generating TR-CBCTA in clinical practice.

  18. Neutron beam applications - Development of single crystal structure analysis technique using the HANARO neutron four circle diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Il Hwan; Kim, Moon Jib; Kim, Jin Gyu [Chungnam National University, Taejon (Korea)

    2000-04-01

    As the four circle diffractometer (FCD) has been set up in HANARO, it has become possible to study the single crystal structures by means of the neutron diffraction. Taking account of the geometry of the FCD, a program for the control of te FCD and neutron data acquisition operating under Windows' circumstance has been accomplished. Also, a computer program which can automatically measure the diffraction intensity data has been developed. All data obtained from the FCD are processed automatically for further work and a software for the single crystal structure analyses has been prepared. A KC1 single crystal was selected as first test sample for a structure analysis had been successfully performed on the FCD using in-house developed program and accordingly their functionings with precision were confirmed. For regular single crystal diffraction experiments, the structure analyses of chrysoberyl and Zr(Y)0{sub 1.87} single crystals were performed using both neutron and X-ray diffraction methods, and the result showed that the neutron diffraction work is superior to the X-ray one from the viewpoint of certain crystallographic information obtainable only from the former one. 24 refs., 15 figs., 15 tabs. (Author)

  19. Higher order modes excitation of electrostatically actuated clamped–clamped microbeams: experimental and analytical investigation

    KAUST Repository

    Jaber, Nizar

    2016-01-06

    © 2016 IOP Publishing Ltd. In this study, we demonstrate analytically and experimentally the excitations of the higher order modes of vibrations in electrostatically actuated clamped-clamped microbeam resonators. The concept is based on using partial electrodes with shapes that induce strong excitation of the mode of interest. The devices are fabricated using polyimide as a structural layer coated with nickel from the top and chrome and gold layers from the bottom. Experimentally, frequency sweeps with different electro-dynamical loading conditions are shown to demonstrate the excitation of the higher order modes of vibration. Using a half electrode, the second mode is excited with high amplitude of vibration compared with almost zero response using the full electrode. Also, using a two-third electrode configuration is shown to amplify the third mode resonance amplitude compared with the full electrode under the same electrical loading conditions. An analytical model is developed based on the Euler-Bernollui beam model and the Galerkin method to simulate the device response. Good agreement between the simulation results and the experimental data is reported.

  20. New active load voltage clamp for HF-link converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, M.A.E.

    2005-07-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core. (au)

  1. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    Due to the increased use of renewable energy and power elctronic applications, more multilevel converters (MLC) are developed. A Neutral Point Clamped (NPC) inverter is one of the most used multilevel topologies for wind turbine (WT) and photovoltaic (PV) applications. One of the most crucial...... points in this type of converter is dc-voltage control. In this paper, a novel multi output dc-dc converter connected to a diode clamped topology is presented. This converter, for a given duty cycles, is able to regulate the capacitor voltage to provide an appropriate input voltage for NPC regardless...

  2. Improved DNA clamps by stacking to adjacent nucleobases

    DEFF Research Database (Denmark)

    Fatthalla, M.I.; Pedersen, Erik Bjerregaard

    2012-01-01

    Three or four aromatic rings interconnected by acetylene bridges form a stiff conjugated system with sufficient conformational freedom to make it useful to link together the two strands of a DNA clamp. Upon targeting a ssDNA, the conformational flexibility allows better stacking of the linker...... to the underlying non-planar base triplet in the formed triplex. This type of triplexes has a substantially higher thermal melting temperature which can be further improved by inserting locked nucleic acids (LNAs) in the Hoogsteen part of the clamp. An extremely high sensitivity to mismatches is observed...

  3. Experimental determination of optimal clamping torque for AB-PEM Fuel cell

    Directory of Open Access Journals (Sweden)

    Noor Ul Hassan

    2016-04-01

    Full Text Available Polymer electrolyte Membrane (PEM fuel cell is an electrochemical device producing electricity by the reaction of hydrogen and oxygen without combustion. PEM fuel cell stack is provided with an appropriate clamping torque to prevent leakage of reactant gases and to minimize the contact resistance between gas diffusion media (GDL and bipolar plates. GDL porous structure and gas permeability is directly affected by the compaction pressure which, consequently, drastically change the fuel cell performance. Various efforts were made to determine the optimal compaction pressure and pressure distributions through simulations and experimentation. Lower compaction pressure results in increase of contact resistance and also chances of leakage. On the other hand, higher compaction pressure decreases the contact resistance but also narrows down the diffusion path for mass transfer from gas channels to the catalyst layers, consequently, lowering cell performance. The optimal cell performance is related to the gasket thickness and compression pressure on GDL. Every stack has a unique assembly pressure due to differences in fuel cell components material and stack design. Therefore, there is still need to determine the optimal torque value for getting the optimal cell performance. This study has been carried out in continuation of deve­lopment of Air breathing PEM fuel cell for small Unmanned Aerial Vehicle (UAV application. Compaction pressure at minimum contact resistance was determined and clamping torque value was calcu­la­ted accordingly. Single cell performance tests were performed at five different clamping torque values i.e 0.5, 1.0, 1.5, 2.0 and 2.5 N m, for achieving optimal cell per­formance. Clamping pressure distribution tests were also performed at these torque values to verify uniform pressure distribution at optimal torque value. Experimental and theoretical results were compared for making inferences about optimal cell perfor­man­ce. A

  4. On the excess photon noise in single-beam measurements with photo-emissive and photo-conductive cells

    NARCIS (Netherlands)

    Alkemade, C.T.J.

    In this paper the so-called excess photon noise is theoretically considered with regard to noise power measurements with a single, illumined photo-emissive or photo-conductive cell. Starting from a modification of Mandel's stochastic association of the emission of photo-electrons with wave

  5. Single-Transverse-Spin-Asymmetry studies with a fixed-target experiment using the LHC beams (AFTER@LHC)

    CERN Document Server

    Lansberg, J.P.; Arnaldi, R.; Brodsky, S.J.; Chambert, V.; Da Silva, C.; Didelez, J.P.; Echevarria, M. G; Ferreiro, E.G.; Fleuret, F.; Gao, Y.; Genolini, B.; Hadjidakis, C.; Hřivnáčová, I.; Kikola, D.; Klein, A.; Kurepin, A.; Kusina, A.; Lorcé, C.; Lyonnet, F.; Massacrier, L.; Nass, A.; Pisano, C.; Robbe, P.; Schienbein, I.; Schlegel, M.; Scomparin, E.; Seixas, J.; Shao, H.S.; Signori, A.; Steffens, E.; Topilskaya, N.; Trzeciak, B.; Uggerhøj, U.I.; Uras, A.; Ulrich, R.; Yang, Z.

    2016-01-01

    We discuss the potential of AFTER@LHC to measure single-transverse-spin asymmetries in open-charm and bottomonium production. With a HERMES-like hydrogen polarised target, such measurements over a year can reach precisions close to the per cent level. This is particularly remarkable since these analyses can probably not be carried out anywhere else

  6. Nanowire assembly, e.g. for optical probes, comprises optically trapping high aspect ratio semiconductor nanowire with infrared single-beam optical trap and attaching nanowire to organic or inorganic structure

    OpenAIRE

    Pauzauskie, P.; Radenovic, A.; Trepagnier, E.; Liphardt, J.; Yang, P.

    2007-01-01

    NOVELTY - A nanowire assembly method comprises optically trapping a semiconductor nanowire with an infrared single-beam optical trap and attaching the nanowire to an organic or inorganic structure by laser fusing. The nanowire is further trapped in a fluid environment. The optical trap has a beam wavelength of 1064 nm. The nanowire has an aspect ratio greater than 100 and a diameter less than 100 (preferably less than 80) nm. The nanowire and the organic or inorganic structure form a heterost...

  7. Ion Accelerator Merges Several Beams

    Science.gov (United States)

    Aston, G.

    1984-01-01

    Intense ion beam formed by merging multiple ion beamlets into one concentrated beam. Beamlet holes in graphite screen and focusing grids arranged in hexagonal pattern. Merged beam passes through single hole in each of aluminum accelerator and decelerator grids. Ion extraction efficiency, beam intensity, and focusing improved.

  8. Characterization of heterologously expressed transporter genes by patch- and voltage-clamp methods: Application to cyclic nucleotide-dependent responses

    KAUST Repository

    Lemtiri-Chlieh, Fouad

    2013-09-03

    The application of patch- and voltage-clamp methods to study ion transport can be limited by many hurdles: the size of the cells to be patched and/or stabbed, the subcellular localization of the molecule of interest, and its density of expression that could be too low even in their own native environment. Functional expression of genes using recombinant DNA technology not only overcomes those hurdles but also affords additional and elegant investigations such as single-point mutation studies and subunit associations/regulations. In this chapter, we give a step-by-step description of two electrophysiological methods, patch clamp and two-electrode voltage clamp (TEVC), that are routinely used in combination with heterologous gene expression to assist researchers interested in the identification and characterization of ion transporters. We describe how to (1) obtain and maintain the cells suitable for the use with each of the above-mentioned methods (i.e., HEK-293 cells and yeast spheroplasts to use with the patch-clamp methodology and Xenopus laevis oocytes with TEVC), (2) transfect/inject them with the gene of interest, and (3) record ion transport activities. © Springer Science+Business Media New York 2013.

  9. Initial results of selective renal parenchymal clamping with an adjustable kidney clamp in nephron-sparing surgery: an easy way to minimise renal ischaemia.

    Science.gov (United States)

    Cheng, K C; Yiu, M K; Ho, S H; Ng, T L; Tsu, H L; Ma, W K

    2016-12-01

    A renal parenchymal clamp has been used at our centre since March 2012. It is used in position over the kidney to achieve optimal vascular control of a tumour while minimising parenchymal ischaemia. This study aimed to report the feasibility, surgical outcome, and oncological control of a kidney clamp in partial nephrectomy. This study was conducted at a teaching hospital in Hong Kong. Partial nephrectomies performed from January 2009 to March 2015 were reviewed. The tumour characteristics and surgical outcomes of kidney clamp were studied and compared with traditional hilar clamping. A total of 92 patients were identified during the study period. Kidney clamps were used in 20 patients and hilar clamping in 72, with a mean follow-up of 27 and 37 months, respectively. For patients in whom a kidney clamp was applied, all tumours were exophytic to a different extent and the majority (90%) were located at the polar region. The PADUA (preoperative aspects and dimensions used for an anatomical) classification nephrometry score was also lower than those in whom hilar clamping was used (7.07 vs 8.34; P=0.002). The clamp was used in open, laparoscopic, and robot-assisted surgery. Operating time was shorter (207 ± 72 mins vs 306 ± 80 mins; Pkidney clamp. No acute kidney injury occurred. Postoperative renal function was comparable between the two groups. Partial nephrectomy using parenchymal clamping is safe and feasible in selected cases. The postoperative renal function and oncological control were satisfactory.

  10. Electric field control of a Bragg diffraction optical beam splitter based on a cubic K(0.99)Li(0.01)Ta(0.63)Nb(0.37)O3 single crystal.

    Science.gov (United States)

    Gong, Dewei; Tian, Hao; Tan, Liying; Zhou, Zhongxiang

    2011-01-01

    We have realized an electric field controlled Bragg diffraction optical beam splitter based on a photorefractive Bragg diffraction grating. In our experiments, the splitter was produced by wave coupling (532.0 nm) with a potassium lithium tantalate niobate single crystal. In the process of splitting, the incident beam could be split into multioutput beams by the splitter. The influence of an externally applied electric field was studied, and the results show that the intensity of the Bragg diffraction could be controlled by the electric field. The polarization properties of the splitter are discussed.

  11. Note: Decoupling design for high frequency piezoelectric ultrasonic transducers with their clamping connections

    Energy Technology Data Exchange (ETDEWEB)

    Wang, F. J., E-mail: wangfujun@tju.edu.cn; Liang, C. M.; Tian, Y. L.; Zhao, X. Y.; Zhang, D. W. [Tianjin Key Laboratory of Equipment Design and Manufacturing Technology, School of Mechanical Engineering, Tianjin University, Tianjin 300072 (China); Zhang, H. J. [Tianjin Key Laboratory of Modern Mechatronics Equipment Technology, School of Mechanical Engineering, Tianjin Polytechnic University, Tianjin 300387 (China)

    2015-12-15

    This work presents the flexure-mechanism based decoupling design between high frequency piezoelectric ultrasonic transducers and their clamping connections to improve ultrasonic energy transmission efficiency. The ring, prismatic beam, and circular notched hinge based flanges were presented, and the crucial geometric dimensions of the transducers with the flexure decoupling flanges were determined. Finite element analysis (FEA) was carried out to investigate the dynamic characteristics of the transducers. Finally, experiments were conducted to examine and verify the effects of the proposed decoupling flanges. FEA and experimental results show that smaller frequency deviations and larger tip displacement amplitudes have been achieved by using the transducers with the flexure flanges compared with the transducer with a rigid ring-type flange, and thus the ultrasonic transmission efficiency can be improved through the flexure flanges.

  12. Revisit of combined parallel-beam/cone-beam or fan-beam/cone-beam imaging.

    Science.gov (United States)

    Zeng, Gengsheng L

    2013-10-01

    This aim of this paper is to revisit the parallel-beam/cone-beam or fan-beam/cone-beam imaging configuration, and to investigate whether this configuration has any advantages. Twenty years ago, it was suggested to simultaneously use a parallel-beam (or a fan-beam) collimator and a cone-beam collimator to acquire single photon emission computed tomography data. The motivation was that the parallel-beam (or the fan-beam) collimator can provide sufficient sampling, while the cone-beam collimator is able to provide higher photon counts. Even with higher total counts, this hybrid system does not give significant improvement (if any) in terms of image noise and artifacts reduction. If a conventional iterative maximum-likelihood expectation-maximization algorithm is used to reconstruct the image, the resultant reconstruction may be worse than the parallel-beam-only (or fan-beam-only) system. This paper uses the singular value decomposition (SVD) analysis to explain this phenomenon. The SVD results indicate that the parallel-beam-only and the fan-beam-only system outperform the combined systems. The optimal imaging system does not necessary to be the one that generates the projections with highest signal-to-noise ratio and best resolution.

  13. Management of Senile Ptosis with Levator Muscle Resection Using the Putterman Clamp

    Science.gov (United States)

    2016-01-01

    Summary: Putterman clamp, a muscle clamp, is commonly used in conjunctival müllerectomies. We report 3 cases of senile ptosis repaired with levator muscle resection using the Putterman clamp. The redundant levator aponeurosis was removed with electrocautery after clamping with the Putterman clamp. The levator muscle was refixed to the tarsus with three 4-0 Vicryl stitches after adjusting the height of the eyelid fissure. No intraoperative difficulties were encountered. Ecchymosis and edema were limited in the immediate postoperative period. No complications were noted during the follow-up. The benefits of using the Putterman clamp in levator muscle resection are illustrated in these cases. PMID:27482474

  14. Strain relaxation in single crystal SrTiO3 grown on Si (001) by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Choi, Miri; Posadas, Agham; Dargis, Rytis; Shih, Chih-Kang; Demkov, Alexander A.; Triyoso, Dina H.; David Theodore, N.; Dubourdieu, Catherine; Bruley, John; Jordan-Sweet, Jean

    2012-01-01

    An epitaxial layer of SrTiO 3 grown directly on Si may be used as a pseudo-substrate for the integration of perovskite oxides onto silicon. When SrTiO 3 is initially grown on Si (001), it is nominally compressively strained. However, by subsequent annealing in oxygen at elevated temperature, an SiO x interlayer can be formed which alters the strain state of SrTiO 3 . We report a study of strain relaxation in SrTiO 3 films grown on Si by molecular beam epitaxy as a function of annealing time and oxygen partial pressure. Using a combination of x-ray diffraction, reflection high energy electron diffraction, and transmission electron microscopy, we describe the process of interfacial oxidation and strain relaxation of SrTiO 3 on Si (001). Understanding the process of strain relaxation of SrTiO 3 on silicon will be useful for controlling the SrTiO 3 lattice constant for lattice matching with functional oxide overlayers.

  15. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng

    2007-01-01

    This paper presents the careful integration of a newly proposed Z-source topological concept to the basic neutral-point-clamped (NPC) inverter topology for designing a three-level inverter with both voltage-buck and voltage-boost capabilities. The designed Z-source NPC inverter uses two unique X-...

  16. A clamp-like biohybrid catalyst for DNA oxidation

    NARCIS (Netherlands)

    van Dongen, S.F.M.; Clerx, J.; Norgaard, K.; Bloemberg, T.G.; Cornelissen, Jeroen Johannes Lambertus Maria; Trakselis, M.A.; Nelson, S.W.; Benkovic, S.J.; Rowan, A.E.; Nolte, R.J.M.

    2013-01-01

    In processive catalysis, a catalyst binds to a substrate and remains bound as it performs several consecutive reactions, as exemplified by DNA polymerases. Processivity is essential in nature and is often mediated by a clamp-like structure that physically tethers the catalyst to its (polymeric)

  17. analytical bending solution of all clamped isotropic rectangular plate

    African Journals Online (AJOL)

    HP

    is the plate flexural rigidity, is the Young's modulus of elasticity of the plate, is the uniformly distributed load, is the deflection, is the modulus of subgrade reaction, is the thickness of the plate and is the. Poisson's ratio of the plate. The independent co-ordinates, x and y, of the clamped plate can be expressed in the form of ...

  18. Beyond the patch clamp: nanotechnologies for intracellular recording.

    Science.gov (United States)

    Kruskal, Peter B; Jiang, Zhe; Gao, Teng; Lieber, Charles M

    2015-04-08

    The patch clamp is a fundamental tool for neuroscientists, offering insights that have shaped our understanding of the brain. Advances in nanotechnology suggest that the next generation of recording methods is now within reach. We discuss the complexity and future promise of applying nanoscience to neural recording. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. INOVASI SAMBUNGAN MEKANIS MENGGUNAKAN CLAMP BAJA UNTUK TULANGAN BETON

    Directory of Open Access Journals (Sweden)

    Parmo

    2015-12-01

    Full Text Available In the last few years, Indonesian urban growth has tends to be lead to the overground space. This was caused by the significant population increasement the lackness of land availability. The phenomenon is also marked with the increasing number of high-rise buildings and skyscrapers. However, high-rise buildings and skyscrapers have the potential dangers against earthquakes, even more Indonesia lay on an earthquake-prone areas. There are two main things that need to be considered in the planning of earthquake-resistant buildings, which is strength and ductility. Deformation capability and the connection strength between the reinforcement taken into consideration in the design of earthquake-resistant structures. From the steel clamp tensile test results for D13’s mechanical connection reinforcement, it gained 270.69 Mpa for yield strength, 351.45 MPa for ultimate tensile strength and 4757 kg for maximum load with 40% elongation. As for the D16’s mechanical connection reinforcement gained 217.80 MPa for yield strength, 327 605 MPa for ultimate tensile strength and 6717 kg for maximum load with 32% elongation. This study uses two pieces of steel clamp, but in order to obtain a better result then it need to be add more clamps while increasing the steel clamp material quality.

  20. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.

    2012-01-01

    for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...

  1. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    discussed in the existing literature. Addressing the previously described issues, this paper focuses on the operational mode analysis of a three-level indirect matrix converter implemented using a neutral-point-clamped inversion stage and the design of a number of PWM and modulation ratio compensation...

  2. Euglycemic clamp insulin sensitivity and longitudinal systolic blood pressure

    DEFF Research Database (Denmark)

    Petrie, John R; Malik, Muhammad Omar; Balkau, Beverley

    2013-01-01

    and Cardiovascular disease (RISC) study, we measured insulin sensitivity (M/I) using the euglycemic clamp technique in 1073 healthy European adults (587 women, 486 men) aged 30 to 60 years followed up 3 years later. Systolic BP (SBP) at baseline was higher in insulin-resistant women (ie, those in the low sex...

  3. Five-level Z-source diode-clamped inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This study proposes a five-level Z-source diode-clamped inverter designed with two intermediate Z-source networks connected between the dc input sources and rear-end inverter circuitry. By partially shorting the Z-source networks, new operating states not previously reported for two-level Z...

  4. Single-beam integrating sphere spectrophotometer for reflectance and transmittance measurements versus angle of incidence in the solar wavelength range on diffuse and specular samples

    Science.gov (United States)

    Nostell, Per; Roos, Arne; Rönnow, Daniel

    1999-05-01

    A multipurpose instrument for the measurement of reflectance and transmittance versus angle of incidence for both specular and diffuse samples in the solar wavelength range has been constructed and evaluated. The instrument operates in the single-beam mode and uses a common light source for three experimental setups. Two integrating spheres, 20 cm in diameter, are used for diffuse transmittance and reflectance measurements. The transmittance sphere can be turned around an axis through the sample to vary the angle of incidence. The reflectance sphere uses a center mounted sample and a special feature is the position of the detector, which is mounted on the sample holder at the center of the sphere. This way the detector always sees the same part of the sphere wall and no light can reach the detector directly from the sample. The third setup is an absolute instrument for specular samples. It uses a small averaging sphere as a detector. The detector is mounted on an arm which rotates around the center of the sample, and it can thus pick up both the reflected and transmitted beams including all multiply reflected components. The averaging sphere detector is insensitive to small side shifts of the detected beams and no multiple reflections between detector and optical system occur. In this report a number of calibration procedures are presented for the three experimental setups and models for the calculation of correct transmittance and reflectance values from measured data are presented. It is shown that for integrating sphere measurements, the geometry of the sphere and the diffusivity of the sample as well as the sphere wall reflectance and port losses are important factors that influence the result. For the center mounted configuration these factors are particularly important and special emphasis is given to the evaluation of the reflectance sphere model. All three instrument setups are calibrated using certified reference materials and nonscattering mirrors and

  5. Hyperinsulinemic Euglycemic Clamp for cardiac PET: An Initial Experience

    International Nuclear Information System (INIS)

    Agrawal, Saumya; Salgia, Ritu; Baikerikar, Sushanti; Khandare, Hemant; Lele, Vikram

    2007-01-01

    Full text: Aim: To study the adequacy of hyperinsulinemic euglycemic clamp to yield technically adequate and clinically meaningful cardiac scans in diabetic patients. 18 F- FDG scans are of suboptimal quality as high level of glucose competes with flurodeoxyglucose for cardiac uptake. Thus to allow quick stabilization of metabolic environment and to get superior quality images, insulin clamp is an accepted technique. Methods: 8 patients (7 males and 1 female) of ages ranging from 43 to 69 years were evaluated in this ongoing study, referred for estimation of myocardial viability post myocardial infarction. All patients were required 6 hours fasting. Initially they were injected with 20 milicurie of Technetium Tetrofosmin and myocardial perfusion imaging done 1 hour later on GE dual head gamma camera. Blood glucose levels were checked. Their blood sugars were in the range of 130mg% - 170mg%. Insulin clamp was applied depending upon the glucose level obtained, according to ASNC guidelines for PET Myocardial Glucose Metabolism and Perfusion Imaging. On stabilization of blood glucose levels, 10 milicurie of 18 F- FDG was injected. Imaging was done 1 hour later on Dedicated 16 slice STE PET CT scanner. There was no incidence of hypoglycemia or any other side effects during the procedure. Entire procedure including tetrofosmin imaging took approximately 4 hours. Results: Good quality images were obtained after the use of insulin clamp. Conclusion: Infusion of insulin and glucose gives stable plasma glucose and serum insulin levels during imaging. The insulin clamp technique makes it possible to adjust and maintain a metabolic steady state during PET study. It does not alter 18F-FDG uptake patterns in different myocardial areas. It permits the use of smaller FDG doses for the patient and gives superior quality images. The technique is safe and should improve both the clinical use and cost effectiveness of FDG-PET imaging for identification of injured but viable myocardium

  6. Diode-pumped, single frequency Nd:YLF laser for 60-beam OMEGA laser pulse-shaping system

    International Nuclear Information System (INIS)

    Okishev, A.V.; Seka, W.

    1997-01-01

    The operational conditions of the OMEGA pulse-shaping system require an extremely reliable and low-maintenance master oscillator. The authors have developed a diode-pumped, single-frequency, pulsed Nd:YLF laser for this application. The laser generates Q-switched pulses of ∼160-ns duration and ∼10-microJ energy content at the 1,053-nm wavelength with low amplitude fluctuations (<0.6% rms) and low temporal jitter (<7 ns rms). Amplitude and frequency feedback stabilization systems have been used for high long-term amplitude and frequency stability

  7. Near-field beam focusing by a single bare subwavelength metal slit with the high-index transmission space.

    Science.gov (United States)

    Guo, Yan; Zhao, Bo; Yang, Jianjun

    2013-06-17

    We theoretically demonstrate that a single bare subwavelength metal slit without any surrounding corrugations can have a capability to steer the incident light into focusing patterns by introducing a high index in the transmission half-space. The focusing properties are identified to depend on both the slit width and the output permittivity. The underlying physics lies in the interference of quasi-cylindrical waves scattered from the slit, and our proposed model agrees well with the simulation results. This finding is believed to inspire some novel ideas for the nano-optics design.

  8. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  9. Impact of Early Release of the IVC Clamp from Different IVC Clamping Maneuvers on Changes in Hemodynamic Parameters in Living Donor Liver Transplantation.

    Science.gov (United States)

    Shih, Tsung-Hsiao; Huang, Chia-Jung; Chen, Chao-Long; Cheng, Kwok-Wai; Wu, Shao-Chun; Yang, Sheng-Chun; Juang, Sin-Ei; Lee, Ying-En; Jawan, Bruno; Wang, Chih-Hsien

    2015-09-06

    BACKGROUND The aim of this study was to evaluate the impact of different methods of inferior vena cava (IVC) clamping and release of the cross clamp on hemodynamic parameters of recipients during living donor liver transplantation. MATERIAL AND METHODS Ninety-six adult living donor liver transplantation patients were divided into 3 groups according to cross-clamp of the IVC for all the hepatic vein and portal vein reconstruction (G1), cross-clamp of the IVC only for hepatic vein reconstruction (G2), and side-clamp of the IVC for hepatic vein reconstruction (G3). In G2 and G2, the reconstructed hepatic vein was clamped instead of the IVC for portal vein reconstruction. The hemodynamic parameters among groups were compared by 1-way ANOVA and the complications in each group were compared using the Kruskal-Wallis test. RESULTS Changes in percentage of MAP and CO in G3 were significantly less than that of G1 and G2 for hepatic vein reconstruction. Hemodynamic parameters of G2 and G3 normalized to pre-clamped values during portal vein reconstruction, while the hemodynamics of G1 remained unstable. CONCLUSIONS Hemodynamic changes were less pronounced in LT with side-clamp of the inferior cava vein versus total cross-clamp. Early release of the IVC clamp minimized the hemodynamic changes. There were no differences in terms of outcome (morbidity and mortality).

  10. Explicit frequency equations of free vibration of a nonlocal Timoshenko beam with surface effects

    Science.gov (United States)

    Zhao, Hai-Sheng; Zhang, Yao; Lie, Seng-Tjhen

    2018-02-01

    Considerations of nonlocal elasticity and surface effects in micro- and nanoscale beams are both important for the accurate prediction of natural frequency. In this study, the governing equation of a nonlocal Timoshenko beam with surface effects is established by taking into account three types of boundary conditions: hinged-hinged, clamped-clamped and clamped-hinged ends. For a hinged-hinged beam, an exact and explicit natural frequency equation is obtained. However, for clamped-clamped and clamped-hinged beams, the solutions of corresponding frequency equations must be determined numerically due to their transcendental nature. Hence, the Fredholm integral equation approach coupled with a curve fitting method is employed to derive the approximate fundamental frequency equations, which can predict the frequency values with high accuracy. In short, explicit frequency equations of the Timoshenko beam for three types of boundary conditions are proposed to exhibit directly the dependence of the natural frequency on the nonlocal elasticity, surface elasticity, residual surface stress, shear deformation and rotatory inertia, avoiding the complicated numerical computation.

  11. Review: The lord of the rings: Structure and mechanism of the sliding clamp loader.

    Science.gov (United States)

    Kelch, Brian A

    2016-08-01

    Sliding clamps are ring-shaped polymerase processivity factors that act as master regulators of cellular replication by coordinating multiple functions on DNA to ensure faithful transmission of genetic and epigenetic information. Dedicated AAA+ ATPase machines called clamp loaders actively place clamps on DNA, thereby governing clamp function by controlling when and where clamps are used. Clamp loaders are also important model systems for understanding the basic principles of AAA+ mechanism and function. After nearly 30 years of study, the ATP-dependent mechanism of opening and loading of clamps is now becoming clear. Here I review the structural and mechanistic aspects of the clamp loading process, as well as comment on questions that will be addressed by future studies. © 2016 Wiley Periodicals, Inc. Biopolymers 105: 532-546, 2016. © 2016 Wiley Periodicals, Inc.

  12. Increased apoptotic potential and dose-enhancing effect of gold nanoparticles in combination with single-dose clinical electron beams on tumor-bearing mice

    International Nuclear Information System (INIS)

    Chang Mengya; Chen Yuhung; Chang Chihjui; Chen Helen H-W; Wu Chaoliang; Shiau Aili

    2008-01-01

    High atomic number material, such as gold, may be used in conjunction with radiation to provide dose enhancement in tumors. In the current study, we investigated the dose-enhancing effect and apoptotic potential of gold nanoparticles in combination with single-dose clinical electron beams on B16F10 melanoma tumor-bearing mice. We revealed that the accumulation of gold nanoparticles was detected inside B16F10 culture cells after 18 h of incubation, and moreover, the gold nanoparticles were shown to be colocalized with endoplasmic reticulum and Golgi apparatus in cells. Furthermore, gold nanoparticles radiosensitized melanoma cells in the colony formation assay (P=0.02). Using a B16F10 tumor-bearing mouse model, we further demonstrated that gold nanoparticles in conjunction with ionizing radiation significantly retarded tumor growth and prolonged survival compared to the radiation alone controls (P<0.05). Importantly, an increase of apoptotic signals was detected inside tumors in the combined treatment group (P<0.05). Knowing that radiation-induced apoptosis has been considered a determinant of tumor responses to radiation therapy, and the length of tumor regrowth delay correlated with the extent of apoptosis after single-dose radiotherapy, these results may suggest the clinical potential of gold nanoparticles in improving the outcome of melanoma radiotherapy. (author)

  13. In-vitro Assessing the Shaping Ability of Three Nickel-Titanium Rotary Single File Systems by Cone Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Ali Imad Al-Asadi

    2018-02-01

    Full Text Available Aim of the study was to evaluate the canal transportation and centering ability of three nickel-titanium single file rotary systems by cone beam computed tomography (CBCT. Materials and methods: Thirty permanent maxillary first molar with a range of mesiobuccal canals curvature from 20-30 degree were selected and assigned into three groups (n=10, according to the biomechanical preparation system used: Hyflex EDM (HF, Reciproc blue (RB and OneShape (OS. The sampled were scanned by CBCT after being mounted on customized acrylic base and then rescanned after the instrumentation. Slices from the axial section were taken from both exposures at 3 mm, 6 mm and 9 mm from the root apex corresponding to the apical, middle, and coronal third respectively. Data were statistically analyzed using Kurskal-Wallis and Mann-Whitney U tests at the 5% confidence level. Results: The results showed that there were no significant differences at the apical and coronal third and a significant difference at the middle third regarding canal transportation. However, there was a significant difference at the apical third and no significant difference at the middle and coronal third regarding centering ratio. Conclusion: It was concluded that the three single rotary systems reported a degree in canal transportation and centric ratio but the Hyflex EDM reported the least one.

  14. Patch-Clamp Recording from Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes: Improving Action Potential Characteristics through Dynamic Clamp

    Science.gov (United States)

    Veerman, Christiaan C.; Zegers, Jan G.; Mengarelli, Isabella; Bezzina, Connie R.

    2017-01-01

    Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great promise for studying inherited cardiac arrhythmias and developing drug therapies to treat such arrhythmias. Unfortunately, until now, action potential (AP) measurements in hiPSC-CMs have been hampered by the virtual absence of the inward rectifier potassium current (IK1) in hiPSC-CMs, resulting in spontaneous activity and altered function of various depolarising and repolarising membrane currents. We assessed whether AP measurements in “ventricular-like” and “atrial-like” hiPSC-CMs could be improved through a simple, highly reproducible dynamic clamp approach to provide these cells with a substantial IK1 (computed in real time according to the actual membrane potential and injected through the patch-clamp pipette). APs were measured at 1 Hz using perforated patch-clamp methodology, both in control cells and in cells treated with all-trans retinoic acid (RA) during the differentiation process to increase the number of cells with atrial-like APs. RA-treated hiPSC-CMs displayed shorter APs than control hiPSC-CMs and this phenotype became more prominent upon addition of synthetic IK1 through dynamic clamp. Furthermore, the variability of several AP parameters decreased upon IK1 injection. Computer simulations with models of ventricular-like and atrial-like hiPSC-CMs demonstrated the importance of selecting an appropriate synthetic IK1. In conclusion, the dynamic clamp-based approach of IK1 injection has broad applicability for detailed AP measurements in hiPSC-CMs. PMID:28867785

  15. Patch-Clamp Recording from Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes: Improving Action Potential Characteristics through Dynamic Clamp.

    Science.gov (United States)

    Verkerk, Arie O; Veerman, Christiaan C; Zegers, Jan G; Mengarelli, Isabella; Bezzina, Connie R; Wilders, Ronald

    2017-08-30

    Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great promise for studying inherited cardiac arrhythmias and developing drug therapies to treat such arrhythmias. Unfortunately, until now, action potential (AP) measurements in hiPSC-CMs have been hampered by the virtual absence of the inward rectifier potassium current ( I K1 ) in hiPSC-CMs, resulting in spontaneous activity and altered function of various depolarising and repolarising membrane currents. We assessed whether AP measurements in "ventricular-like" and "atrial-like" hiPSC-CMs could be improved through a simple, highly reproducible dynamic clamp approach to provide these cells with a substantial I K1 (computed in real time according to the actual membrane potential and injected through the patch-clamp pipette). APs were measured at 1 Hz using perforated patch-clamp methodology, both in control cells and in cells treated with all-trans retinoic acid (RA) during the differentiation process to increase the number of cells with atrial-like APs. RA-treated hiPSC-CMs displayed shorter APs than control hiPSC-CMs and this phenotype became more prominent upon addition of synthetic I K1 through dynamic clamp. Furthermore, the variability of several AP parameters decreased upon I K1 injection. Computer simulations with models of ventricular-like and atrial-like hiPSC-CMs demonstrated the importance of selecting an appropriate synthetic I K1 . In conclusion, the dynamic clamp-based approach of I K1 injection has broad applicability for detailed AP measurements in hiPSC-CMs.

  16. Active energy recovery clamping circuit to improve the performance of power converters

    Science.gov (United States)

    Whitaker, Bret; Barkley, Adam

    2017-05-09

    A regenerative clamping circuit for a power converter using clamping diodes to transfer charge to a clamping capacitor and a regenerative converter to transfer charge out of the clamping capacitor back to the power supply input connection. The regenerative converter uses a switch connected to the midpoint of a series connected inductor and capacitor. The ends of the inductor and capacitor series are connected across the terminals of the power supply to be in parallel with the power supply.

  17. Four- year thyroidectomy procedures: Ligasure Vs. clamp & tie

    Directory of Open Access Journals (Sweden)

    Pazoki AR

    2010-01-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: The electrothermal bipolar vessel sealing system is an adjunct to the hemostatic technique, which has been successfully used in many abdominal operation, recently made available to thyroid surgery. The purpose of this was compare the outcomes of new hemostatic technique with traditional method of clamp and tie."n"nMethods: In this retrospective cross-sectional study has been done in surgery's wards of Milad & Rasul- Akram hospitals in Tehran, Iran. During three- year period between 2005-2008 all patients with different kind of pathology that need operation were assessed. Time duration of surgery and hospital stay and post surgery complication in two group, ligasure (n=45 and clamp & tie (n=145 were compared with each others."n"nResults: No difference was seen between two groups in time duration of surgery. Significant difference was seen in hospital stay and complications of surgery. Time of operation in Ligasure group was 132/22 minute and in clamp and tie group was 130/10 minute. There was found significant difference in duration of hospital stay and postoperative complication. Hypocalcemia were seen in two and 24 cases in Ligasure and Clamp & Tie group, respectively (p<0.05. Hospital stay was 2

  18. Statics and rotational dynamics of composite beams

    CERN Document Server

    Ghorashi, Mehrdaad

    2016-01-01

    This book presents a comprehensive study of the nonlinear statics and dynamics of composite beams and consists of solutions with and without active elements embedded in the beams. The static solution provides the initial conditions for the dynamic analysis. The dynamic problems considered include the analyses of clamped (hingeless) and articulated (hinged) accelerating rotating beams. Two independent numerical solutions for the steady state and the transient responses are presented. The author illustrates that the transient solution of the nonlinear formulation of accelerating rotating beam converges to the steady state solution obtained by the shooting method. Other key areas considered include calculation of the effect of perturbing the steady state solution, coupled nonlinear flap-lag dynamics of a rotating articulated beam with hinge offset and aerodynamic damping, and static and dynamic responses of nonlinear composite beams with embedded anisotropic piezo-composite actuators. The book is intended as a t...

  19. Pressure controlled clamp using shape memory alloy for minimal vessel invasion in blood flow occlusion.

    Science.gov (United States)

    Zhang, Ye; Kanetaka, Hiroyasu; Sano, Yuya; Kano, Mitsuhiro; Kudo, Tadaaki; Sato, Takumi; Shimizu, Yoshinaka

    2013-01-01

    Vessel damage after clamping may affect the success of surgical operations. A new pressure controlled clamp (SMA clamp) was designed using super elastic property of shape memory alloy (SMA) to realize atraumatic vessel occlusion. The ability and biological effect of the SMA clamp to control pressure was investigated in vivo. The loading-displacement curves of the SMA clamps (experimental group) and conventional clamp (control group) by occlusion of pig carotid arteries were evaluated using a clamping-pressure analyzing system. To investigate macroscopically and histologically the vessel damage of the SMA and conventional clamps, pig carotid arteries were stained with Evan's blue and its histological sections were stained with Elastica Massion after clamping for fifteen minutes. Constant value was shown in the loading-displacement curve of SMA clamp. In the control group, damaged area stained with Evan's blue in the vessel wall showed enlargement with the pressure increasing. Less areas in experimental groups are observed than that in the control group. Histological section in the experimental group showed no obvious except a slight compressive damage in the tunica intima. In the control group, vessel wall showed irreversible damages. This experiment indicated that the SMA clamp, which has a unique mechanical property, can be used without vessels damage. This pressure controlled clamp can be a selection in clinical apparatus to improve surgical safety.

  20. Scanned ion beam therapy for prostate carcinoma. Comparison of single plan treatment and daily plan-adapted treatment

    International Nuclear Information System (INIS)

    Hild, Sebastian; Graeff, Christian; Rucinski, Antoni; Zink, Klemens; Habl, Gregor; Durante, Marco; Herfarth, Klaus; Bert, Christoph

    2016-01-01

    Intensity-modulated particle therapy (IMPT) for tumors showing interfraction motion is a topic of current research. The purpose of this work is to compare three treatment strategies for IMPT to determine potential advantages and disadvantages of ion prostate cancer therapy. Simulations for three treatment strategies, conventional one-plan radiotherapy (ConvRT), image-guided radiotherapy (IGRT), and online adaptive radiotherapy (ART) were performed employing a dataset of 10 prostate cancer patients with six CT scans taken at one week intervals. The simulation results, using a geometric margin concept (7-2 mm) as well as patient-specific internal target volume definitions for IMPT were analyzed by target coverage and exposure of critical structures on single fraction dose distributions. All strategies led to clinically acceptable target coverage in patients exhibiting small prostate motion (mean displacement < 4 mm), but IGRT and especially ART led to significant sparing of the rectum. In 20 % of the patients, prostate motion exceeded 4 mm causing insufficient target coverage for ConvRT (V95 mean = 0.86, range 0.63-0.99) and IGRT (V95 mean = 0.91, range 0.68-1.00), while ART maintained acceptable target coverage. IMPT of prostate cancer demands consideration of rectal sparing and adaptive treatment replanning for patients exhibiting large prostate motion. (orig.) [de

  1. Control and analysis of a single-link flexible beam with experimental verification. Robotics Technology Development Program

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, J.F.

    1992-12-01

    The objective of this report is to ascertain the general conditions for the avoidance and reduction of residual vibration in a flexible manipulator. Conventional manipulators usually have a 1.5 to 2-m reach, and their associated dynamic models typically are composed of lumped parameter elements; the major compliance emanates from the drive trains because of torsional loading effects. The energy storage of the drive system is predominantly potential energy because of the low inertia in the drive train; thus simple spring models have been adequate. A long-reach manipulator with a large aspect ratio (length to diameter) is a fundamentally different problem. Energy storage for this type of manipulator is distributive by nature because of the potential energy resulting from bending and the kinetic energy due to deflection rates. Instead of ordinary differential equations, partial differential equations are required to describe this system, making the analysis more difficult. The general flexibility problem associated with a distributive dynamic system, with specific emphasis on flexible manipulator, will be addressed in this report. Furthermore, three control schemes will be discussed and demonstrated on a single flexible manipulator to determine their general merits.

  2. Facial bone alterations on maxillary anterior single implants for immediate placement and provisionalization following tooth extraction: a superimposed cone beam computed tomography study.

    Science.gov (United States)

    Morimoto, Taichiro; Tsukiyama, Yoshihiro; Morimoto, Keizo; Koyano, Kiyoshi

    2015-12-01

    The purpose of this cone beam computed tomography (CBCT) study was to describe the facial bone changes around single implants for immediate placement and provisionalization following tooth extraction in the maxillary anterior. The data between 2008 and 2013 were collected retrospectively. Superimposed facio-palatal cross-sectional CBCT images for the implants were derived from preoperative and postoperative radiographs via standardized CBCT processes. Horizontal and vertical facial measurements on the implants were identified at preoperative and approximately 1-year postoperative follow-ups. Correlation coefficient for those parameters was evaluated. A total of 12 single implants in 12 patients were included in this study. The mean loading period was 13.3 months (range 12-15 months). The median data of preoperative bone thickness 0.54 mm (A), preoperative vertical bone level 1.46 mm (B), postoperative bone thickness 1.77 mm (C), postoperative vertical bone level 1.08 mm (D), horizontal distance from outer surface of preoperative facial bone to implant surface 2.08 mm (E), horizontal gap distance 1.41 mm (E-A), horizontal bone resorption -0.26 mm (E-C), and vertical bone resorption -0.25 mm (B-D) were obtained. The data at the implant platform level (IPL) were selected for the horizontal measurements. Spearman's analysis demonstrated statistically significant correlations between B and D, C and E, E and E-A, and B and E-C (P Immediate placement and provisionalization of single implants procedure in the maxillary anterior showed excellent outcomes with the small facial bone alterations around the implants. Neither preoperative facial bone thickness nor horizontal gap distance influenced the amount of facial bone resorptions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Optimization of Natural Frequencies and Sound Power of Beams Using Functionally Graded Material

    Directory of Open Access Journals (Sweden)

    Nabeel T. Alshabatat

    2014-01-01

    Full Text Available This paper presents a design method to optimize the material distribution of functionally graded beams with respect to some vibration and acoustic properties. The change of the material distribution through the beam length alters the stiffness and the mass of the beam. This can be used to alter a specific beam natural frequency. It can also be used to reduce the sound power radiated from the vibrating beam. Two novel volume fraction laws are used to describe the material volume distributions through the length of the FGM beam. The proposed method couples the finite element method (for the modal and harmonic analysis, Lumped Parameter Model (for calculating the power of sound radiation, and an optimization technique based on Genetic Algorithm. As a demonstration of this technique, the optimization procedure is applied to maximize the fundamental frequency of FGM cantilever and clamped beams and to minimize the sound radiation from vibrating clamped FGM beam at a specific frequency.

  4. Gigaseal formation in patch clamping with applications of nanotechnology

    CERN Document Server

    Malboubi, Majid

    2014-01-01

    This book presents an investigation of gigaseal formation using micro/nanotechnology. The aims of the book are twofold. First, it explains the mechanisms of gigaseal formation using the latest discoveries. Second, it provides practical techniques for frequent formation of high resistance seals. The formation of a high-resistance electrical seal, also known as a gigaseal, between a cell membrane and a glass micropipette tip is essential in patch-clamp experiments. Even though four decades have passed since the introduction of the patch-clamping technique by Neher and Sakmann, gigaseal formation remains an obstacle in developing the high-throughput ion channel screening systems required by the pharmaceutical industry. Here the authors share their latest methods for achieving gigaseal formation and describe techniques that are highly desirable at both research and industrial levels. Nanotechnology has been found to be a powerful tool for studying and modifying glass micropipettes and in tackling the problem of g...

  5. Analysis of the Pallet Clamping Conditions in Work Positioning

    OpenAIRE

    L. A. Kolesnikov

    2016-01-01

    Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and ...

  6. Broad Beam and Ion Microprobe Studies of Single-Event Upsets in High Speed 0.18micron Silicon Germanium Heterojunction Bipolar Transistors and Circuits

    Science.gov (United States)

    Reed, Robert A.; Marshall, Paul W.; Pickel, Jim; Carts, Martin A.; Irwin, TIm; Niu, Guofu; Cressler, John; Krithivasan, Ramkumar; Fritz, Karl; Riggs, Pam

    2003-01-01

    SiGe based technology is widely recognized for its tremendous potential to impact the high speed microelectronic industry, and therefore the space industry, by monolithic incorporation of low power complementary logic with extremely high speed SiGe Heterojunction Bipolar Transistor (HBT) logic. A variety of studies have examined the ionizing dose, displacement damage and single event characteristics, and are reported. Accessibility to SiGe through an increasing number of manufacturers adds to the importance of understanding its intrinsic radiation characteristics, and in particular the single event effect (SEE) characteristics of the high bandwidth HBT based circuits. IBM is now manufacturing in its 3rd generation of their commercial SiGe processes, and access is currently available to the first two generations (known as and 6HP) through the MOSIS shared mask services with anticipated future release of the latest (7HP) process. The 5 HP process is described and is characterized by a emitter spacing of 0.5 micron and a cutoff frequency ff of 50 GHz, whereas the fully scaled 7HP HBT employs a 0.18 micron emitter and has an fT of 120 GHz. Previous investigations have the examined SEE response of 5 HP HBT circuits through both circuit testing and modeling. Charge collection modeling studies in the 5 H P process have also been conducted, but to date no measurements have been reported of charge collection in any SiGe HBT structures. Nor have circuit models for charge collection been developed in any version other than the 5 HP HBT structure. Our investigation reports the first indications of both charge collection and circuit response in IBM s 7HP-based SiGe process. We compare broad beam heavy ion SEU test results in a fully function Pseudo-Random Number (PRN) sequence generator up to frequencies of 12 Gbps versus effective LET, and also report proton test results in the same circuit. In addition, we examine the charge collection characteristics of individual 7HP HBT

  7. Role of the Checkpoint Clamp in DNA Damage Response

    Directory of Open Access Journals (Sweden)

    Mihoko Kai

    2013-01-01

    Full Text Available DNA damage occurs during DNA replication, spontaneous chemical reactions, and assaults by external or metabolism-derived agents. Therefore, all living cells must constantly contend with DNA damage. Cells protect themselves from these genotoxic stresses by activating the DNA damage checkpoint and DNA repair pathways. Coordination of these pathways requires tight regulation in order to prevent genomic instability. The checkpoint clamp complex consists of Rad9, Rad1 and Hus1 proteins, and is often called the 9-1-1 complex. This PCNA (proliferating cell nuclear antigen-like donut-shaped protein complex is a checkpoint sensor protein that is recruited to DNA damage sites during the early stage of the response, and is required for checkpoint activation. As PCNA is required for multiple pathways of DNA metabolism, the checkpoint clamp has also been implicated in direct roles in DNA repair, as well as in coordination of the pathways. Here we discuss roles of the checkpoint clamp in DNA damage response (DDR.

  8. Correlation of open cell-attached and excised patch clamp techniques.

    Science.gov (United States)

    Filipovic, D; Hayslett, J P

    1995-11-01

    The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

  9. A direct proofreader-clamp interaction stabilizes the Pol III replicase in the polymerization mode

    KAUST Repository

    Jergic, Slobodan

    2013-02-22

    Processive DNA synthesis by the αÉ"θ core of the Escherichia coli Pol III replicase requires it to be bound to the β 2 clamp via a site in the α polymerase subunit. How the É" proofreading exonuclease subunit influences DNA synthesis by α was not previously understood. In this work, bulk assays of DNA replication were used to uncover a non-proofreading activity of É". Combination of mutagenesis with biophysical studies and single-molecule leading-strand replication assays traced this activity to a novel β-binding site in É" that, in conjunction with the site in α, maintains a closed state of the αÉ"θ-β 2 replicase in the polymerization mode of DNA synthesis. The É"-β interaction, selected during evolution to be weak and thus suited for transient disruption to enable access of alternate polymerases and other clamp binding proteins, therefore makes an important contribution to the network of protein-protein interactions that finely tune stability of the replicase on the DNA template in its various conformational states. © 2013 European Molecular Biology Organization.

  10. Laser microsurgery of higher plant cell walls permits patch-clamp access

    Science.gov (United States)

    Henriksen, G. H.; Taylor, A. R.; Brownlee, C.; Assmann, S. M.; Evans, M. L. (Principal Investigator)

    1996-01-01

    Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometers in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K(+)-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue.

  11. Patch clamp and perfusion techniques for studying ion channels expressed in Xenopus oocytes.

    Science.gov (United States)

    Yang, Junqiu; Delaloye, Kelli; Lee, Urvi S; Cui, Jianmin

    2011-01-10

    The protocol presented here is designed to study the activation of the large conductance, voltage- and Ca(2+)-activated K(+) (BK) channels. The protocol may also be used to study the structure-function relationship for other ion channels and neurotransmitter receptors. BK channels are widely expressed in different tissues and have been implicated in many physiological functions, including regulation of smooth muscle contraction, frequency tuning of inner hair cells and regulation of neurotransmitter release. BK channels are activated by membrane depolarization and by intracellular Ca(2+) and Mg(2+). Therefore, the protocol is designed to control both the membrane voltage and the intracellular solution. In this protocol, messenger RNA of BK channels is injected into Xenopus laevis oocytes (stage V-VI) followed by 2-5 days of incubation at 18°C. Membrane patches that contain single or multiple BK channels are excised with the inside-out configuration using patch clamp techniques. The intracellular side of the patch is perfused with desired solutions during recording so that the channel activation under different conditions can be examined. To summarize, the mRNA of BK channels is injected into Xenopus laevis oocytes to express channel proteins on the oocyte membrane; patch clamp techniques are used to record currents flowing through the channels under controlled voltage and intracellular solutions.

  12. The Dynamics of a Doubly Clamped Microbeam Near the Primary Resonance: Experimental and Analytical Investigation

    KAUST Repository

    Masri, Karim M.

    2016-01-20

    We present experimental and analytical investigation of the dynamics of a doubly clamped microbeam near its primary resonance. The microbeam is excited electrostatically by an electrode on the first half of the beam. These microbeams are fabricated using polyimide as structural layer coated with nickel from top and chromium and gold layers from bottom. A noise signal is applied to experimentally detect the natural frequencies. Then, frequency sweep tests are generated for various values of DC bias revealing hardening, transition, and softening behavior of the microbeam. We report for the first time the transition from lower stable state, to unstable state, and then to large stable state experimentally. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. Shooting method is used to find the periodic motion and is utilized to generate frequency response curves. The curves show good agreement with the experimental results with hardening behavior at lower DC voltage then softening at higher voltage loads and dynamic pull-in. © Copyright 2015 by ASME.

  13. Dynamics of a clamped–clamped microbeam resonator considering fabrication imperfections

    KAUST Repository

    Bataineh, Ahmad M.

    2014-10-18

    We present an investigation into the static and dynamic behavior of an electrostatically actuated clamped–clamped polysilicon microbeam resonator accounting for its fabrication imperfections, which are commonly encountered in similar microstructures. These are mainly because of the initial deformation of the beam due to stress gradient and its flexible anchors. First, we show experimental data of the microbeam when driven electrically by varying the amplitude and frequency of the voltage loads. The results reveal several interesting nonlinear phenomena of jumps, hysteresis, and softening behaviors. Theoretical investigation is then conducted to model the microbeam, and hence, interpret the experimental data. We solve the Eigen value problem governing the natural frequencies analytically. We then utilize a Galerkin-based procedure to derive a reduced order model, which is then used to simulate both the static and dynamic responses. To achieve good matching between theory and experiment, we show that the exact profile of the deformed beam needs to be utilized in the reduced order model, as measured from the optical profiler, combined with a shooting technique simulation, which is capable of tracing the resonant frequency branches under very-low damping conditions.

  14. Evaluation influence of machining parameters on shape form errors in turning of machine parts clamped in the chuck with adaptive jaws

    Directory of Open Access Journals (Sweden)

    I.V. Lutsiv

    2017-12-01

    Full Text Available The paper deals with the derivation problem of the dependence of machine part geometric form deviation in cross section area on clamping diameter as well as cutting speed, feed and cutting depth in semi finish machining. The analysis of single factor circular deviation dependences on machining conditions values is performed. Using the special software application package the laboratory conditions experiment results are analyzed. The dispersion analysis including options for main linear and quadratic effects evaluation is given and the simplification model of experiment results is obtained. It presents the evaluation empiric dependence of cutting conditions and clamping diameter influence on shape error forming (dynamic error. It is found that to obtain the necessary form accuracy in machining with lathe chuck equipped with the adaptive clamping jaws it is desirable to control the most statistically significant factors that actually are the cutting depth and feed.

  15. Scanned ion beam therapy for prostate carcinoma. Comparison of single plan treatment and daily plan-adapted treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hild, Sebastian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); University Clinic Erlangen and Friedrich- Alexander-University Erlangen-Nuernberg (FAU), Department of Radiation Oncology, Erlangen (Germany); Graeff, Christian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); Rucinski, Antoni [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Sapienza Universit' a di Roma, Dipartimento di Scienze di Base e Applicate per Ingegneria, Roma (Italy); INFN, Roma (Italy); Zink, Klemens [University of Applied Sciences, Institute for Medical Physics and Radiation Protection, Giessen (Germany); University Medical Center Giessen-Marburg, Department of Radiotherapy and Radiooncology, Marburg (Germany); Habl, Gregor [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen (TUM), Department of Radiation Oncology, Munich (Germany); Durante, Marco [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); Technische Universitaet Darmstadt, Faculty of Physics, Darmstadt (Germany); Herfarth, Klaus [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Bert, Christoph [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); University Clinic Erlangen and Friedrich- Alexander-University Erlangen-Nuernberg (FAU), Department of Radiation Oncology, Erlangen (Germany); University Hospital Erlangen, Radiation Oncology, Erlangen (Germany)

    2016-02-15

    Intensity-modulated particle therapy (IMPT) for tumors showing interfraction motion is a topic of current research. The purpose of this work is to compare three treatment strategies for IMPT to determine potential advantages and disadvantages of ion prostate cancer therapy. Simulations for three treatment strategies, conventional one-plan radiotherapy (ConvRT), image-guided radiotherapy (IGRT), and online adaptive radiotherapy (ART) were performed employing a dataset of 10 prostate cancer patients with six CT scans taken at one week intervals. The simulation results, using a geometric margin concept (7-2 mm) as well as patient-specific internal target volume definitions for IMPT were analyzed by target coverage and exposure of critical structures on single fraction dose distributions. All strategies led to clinically acceptable target coverage in patients exhibiting small prostate motion (mean displacement < 4 mm), but IGRT and especially ART led to significant sparing of the rectum. In 20 % of the patients, prostate motion exceeded 4 mm causing insufficient target coverage for ConvRT (V95{sub mean} = 0.86, range 0.63-0.99) and IGRT (V95{sub mean} = 0.91, range 0.68-1.00), while ART maintained acceptable target coverage. IMPT of prostate cancer demands consideration of rectal sparing and adaptive treatment replanning for patients exhibiting large prostate motion. (orig.) [German] Adaptive Therapieansaetze fuer sich interfraktionell bewegende Zielvolumina in der intensitaetsmodulierten Partikeltherapie (IMPT) befinden sich zurzeit in der Entwicklung. In dieser Arbeit werden drei Behandlungsstrategien auf moegliche Vor- und Nachteile in der IMPT des Prostatakarzinoms hin untersucht. Auf Basis eines anonymisierten Datensatzes aus 10 Patienten mit Prostatakarzinom wurden die drei Bestrahlungsstrategien, konventionelle Ein-Plan-Strahlentherapie (ConvRT), bildunterstuetzte Strahlentherapie (IGRT) und tagesaktuelle Strahlentherapie (adaptive radiotherapy,ART), simuliert

  16. Microsurgical Hepatic Artery Reconstruction Using Ikuta A-II Double Clamp.

    Science.gov (United States)

    Okochi, Masayuki; Okochi, Hiromi; Sakaba, Takao; Momiyama, Masanori; Ueda, Kazuki

    2017-05-01

    We performed hepatic artery (HA) reconstruction on 24 patients between January 2010 and October 2016. Six of 24 patients used an Ikuta type A-II vascular clamp (A-II group). The mean age was 38.0 years (range, 1-61 years). There was no blood leakage at the anastomosed site in any of the patients. No patients required an additional vascular clamp, and none developed HA thrombosis. Eighteen of 24 patients used a conventional vascular clamp. The mean age was 36.1 years (range, 1-65 years; conventional group). Sixteen of 18 patients required an additional vascular clamp due to blood leakage from the HA. There was no significant difference between the 2 groups in mean age or diameter of the recipient HA. However, there was a significant difference in the proportion of patients who required an additional vascular clamp (n clamp is an effective vascular clamp for reconstruction of the HA in living donor liver transplantation.

  17. Dose painting to treat single-lobe prostate cancer with hypofractionated high-dose radiation using targeted external beam radiation: Is it feasible?

    International Nuclear Information System (INIS)

    Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.; Ryan, Nicole; Raben, David

    2015-01-01

    Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involved lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V 70 (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V 70 was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB

  18. Proposal for a Full-Scale Prototype Single-Phase Liquid Argon Time Projection Chamber and Detector Beam Test at CERN

    CERN Document Server

    Kutter, T

    2015-01-01

    The Deep Underground Neutrino Experiment (DUNE) will use a large liquid argon (LAr) detector to measure the CP violating phase, determine the neutrino mass hier- archy and perform precision tests of the three-flavor paradigm in long-baseline neutrino oscillations. The detector will consist of four modules each with a fiducial mass of 10 kt of LAr and due to its unprecedented size will allow sensitive searches for proton decay and the detection and measurement of electron neutrinos from core collapse supernovae [1]. The first 10 kt module will use single-phase LAr detection technique and be itself modular in design. The successful manufacturing, installation and operation of several full-scale detector components in a suitable configuration represents a critical engineering milestone prior to the construction and operation of the first full 10 kt DUNE detector module at the SURF underground site. A charged particle beam test of a prototype detector will provide critical calibration measurements as well as inva...

  19. Umbilical cord clamping at birth--practice in Norwegian maternity wards.

    Science.gov (United States)

    Lundberg, Camilla; Øian, Pål; Klingenberg, Claus

    2013-11-26

    The timing and practice used for umbilical cord clamping of neonates are controversial internationally as well as in Norway. We therefore wished to investigate routines and practices for umbilical cord clamping of neonates in Norway. A web-based questionnaire was sent to heads of departments of all maternity wards in Norway (n = 52). They were asked about their practice with regard to umbilical cord clamping of neonates and whether written routines had been prepared for this purpose. We defined early umbilical cord clamping as immediate or within 30 seconds and late clamping as ≥ 1 minute or not until pulsation in the umbilical cord had ceased. Fifty (96%) of the maternity institutions returned a completed questionnaire. Twelve institutions (24%) reported to clamp the umbilical cord of full-term neonates early, and 38 (76%) reported to practise late clamping. Nineteen maternity wards (38%) followed written routines for umbilical cord clamping of full-term neonates, and among these, early umbilical cord clamping was practised in nine (47%). In the 31 maternity wards that had no written routines, early umbilical cord clamping was practised in three (10%). Twenty-seven of the maternity wards reported that the child is placed on the maternal abdomen before clamping of the umbilical cord, 14 reported that the child commonly is held below the introitus before umbilical cord clamping, and the rest did not report any consistent practice. There is wide variation in the practice for umbilical cord clamping in Norwegian maternity wards, many of which have no written guidelines. We argue that national guidelines for umbilical cord clamping of neonates should be established.

  20. M. tuberculosis Sliding β-Clamp Does Not Interact Directly with the NAD+ -Dependent DNA Ligase

    Science.gov (United States)

    Kukshal, Vandna; Khanam, Taran; Chopra, Deepti; Singh, Nidhi; Sanyal, Sabyasachi; Ramachandran, Ravishankar

    2012-01-01

    The sliding β-clamp, an important component of the DNA replication and repair machinery, is drawing increasing attention as a therapeutic target. We report the crystal structure of the M. tuberculosis β-clamp (Mtbβ-clamp) to 3.0 Å resolution. The protein crystallized in the space group C2221 with cell-dimensions a = 72.7, b = 234.9 & c = 125.1 Å respectively. Mtbβ-clamp is a dimer, and exhibits head-to-tail association similar to other bacterial clamps. Each monomer folds into three domains with similar structures respectively and associates with its dimeric partner through 6 salt-bridges and about 21 polar interactions. Affinity experiments involving a blunt DNA duplex, primed-DNA and nicked DNA respectively show that Mtbβ-clamp binds specifically to primed DNA about 1.8 times stronger compared to the other two substrates and with an apparent Kd of 300 nM. In bacteria like E. coli, the β-clamp is known to interact with subunits of the clamp loader, NAD+ -dependent DNA ligase (LigA) and other partners. We tested the interactions of the Mtbβ-clamp with MtbLigA and the γ-clamp loader subunit through radioactive gel shift assays, size exclusion chromatography, yeast-two hybrid experiments and also functionally. Intriguingly while Mtbβ-clamp interacts in vitro with the γ-clamp loader, it does not interact with MtbLigA unlike in bacteria like E. coli where it does. Modeling studies involving earlier peptide complexes reveal that the peptide-binding site is largely conserved despite lower sequence identity between bacterial clamps. Overall the results suggest that other as-yet-unidentified factors may mediate interactions between the clamp, LigA and DNA in mycobacteria. PMID:22545130

  1. Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ning; Ghebremedhin, Abiel; Patyal, Baldev, E-mail: bpatyal@llu.eduss [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California 92354 (United States)

    2015-06-15

    Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm{sup 3} Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on

  2. Passivation of the surfaces of single crystal gadolinium molybdate (Gd2(MoO4)3) against attack by hydrofluoric acid by inert ion beam irradiation

    International Nuclear Information System (INIS)

    Bhalla, A.; Cross, L.E.; Tongson, L.

    1978-01-01

    The passivation effect from inert ion beam bombardment has been studied on a ferroelectric surface. The mechanism in these materials may have some additional contributions because of the polarization charges of the domains and the dipole effect (ion beam and surface species) on the surfaces. For these studies Gd 2 (MoO 4 ) 3 (GMO) crystals were selected. Two possible mechanisms of passivation of GMO surfaces when bombarded with ion beams are discussed

  3. The effect of thermal de-phasing on the beam quality of a high-power single-pass second harmonic generation

    Science.gov (United States)

    Sadat Hashemi, Somayeh; Ghavami Sabouri, Saeed; Khorsandi, Alireza

    2018-04-01

    We present a theoretical model in order to study the effect of a thermally loaded crystal on the quality of a second-harmonic (SH) beam generated in a high-power pumping regime. The model is provided based on using a particular structure of oven considered for MgO:PPsLT nonlinear crystal to compensate for the thermal de-phasing effect that as the pumping power reaches up to 50 W degrades the conversion efficiency and beam quality of the interacting beams. Hereupon, the quality of fundamental beam is involved in the modeling to investigate the final effect on the beam quality of generated SH beam. Beam quality evaluation is subsequently simulated using Hermite–Gaussian modal decomposition approach for a range of fundamental beam qualities varied from 1 to 3 and for different levels of input powers. To provide a meaningful comparison numerical simulation is correlated with real data deduced from a high-power SH generation (SHG) experimental device. It is found that when using the open-top oven scheme and fixing the fundamental M 2-factor at nearly 1, for a range of input powers changing from 15 to 30 W, the M 2-factor of SHG beam is degraded from 9% to 24%, respectively, confirming very good consistency with the reported experimental results.

  4. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  5. Spatial superpositions of Gaussian beams

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2014-02-01

    Full Text Available ., “Bottle beam from a bare laser for single-beam trapping,” Appl. Opt. 43, 6001–6006 (2004). [11] Ahluwalia B. P. S., Yuan X. C. and Tao S. H., “Generation of self-imaged optical bottle beams,” Opt. Commun. 238, 177–184 (2004). [12] Isenhower L...

  6. Beam-beam studies for FCC-hh

    CERN Document Server

    AUTHOR|(CDS)2068329; Pieloni, Tatiana; Buffat, Xavier; Furuseth, Sondre Vik

    2017-01-01

    The Future Circular Collider hadron-hadron (FCC-hh) design study is currently exploring different IR design possibilities including round and flat optics or different crossing schemes. The present study intends to evaluate each scenario from the beam-beam effects point of view. In particular the single particle long term stability to maximize beam lifetimes and luminosity reach is used to quantify the differences. The impact of strong head on interactions on the beam quality and lifetime is addressed by means of GPU accelerated simulations code featuring a weak-strong 6-dimensional beam-beam interaction.

  7. High intensity beam dump for the Tevatron beam abort system

    International Nuclear Information System (INIS)

    Kidd, J.; Mokhov, N.; Murphy, T.; Palmer, M.; Toohig, T.; Turkot, F.; VanGinneken, A.

    1981-01-01

    The beam abort system proposed for the Fermilab Tevatron Accelerator will extract the proton beam from the ring in a single turn (approximately 20/mu/s) and direct it to an external beam dump. It is the function of the beam dump to absorb the unwanted beam and limit the escaping radiation to levels that are acceptable to the surrounding populace and apparatus. A beam dump that is expected to meet these requirements has been designed and constructed. Detailed design of the dump, including considerations leading to the choice of materials, are given. 6 refs

  8. The pharmacokinetic and pharmacodynamic properties of different formulations of biphasic insulin aspart: a randomized, glucose clamp, crossover study.

    Science.gov (United States)

    Heise, T; Eckers, U; Kanc, K; Nielsen, J N; Nosek, L

    2008-12-01

    Type 2 diabetes patients on premixed insulin are commonly prescribed biphasic insulin with low prandial insulin content, such as biphasic insulin aspart (BIAsp) 30, comprising 30% insulin aspart (IAsp). The new formulations BIAsp 50 and BIAsp 70 contain 50% and 70% soluble IAsp, respectively. We compared the pharmacodynamics (PD) and pharmacokinetics (PK) of BIAsp 30, 50, and 70 and IAsp in a glucose clamp trial. In this randomized, double-blind, crossover study at a clinical research institute, 32 type 1 diabetes patients on basal-bolus therapy each underwent four glucose clamps (clamp level 5 mmol/L, duration 28 h post-dosing [12 h for IAsp]) and received a single dose of 0.4 U/kg BIAsp 30, 50, or 70 and IAsp. Main PD/PK outcome parameters measured were early- and late-phase glucose disposal (area under the curve of glucose infusion rate [AUC(GIR)]), nonesterified fatty acid concentrations, and IAsp concentrations. With increasing proportions of soluble IAsp, the insulin formulations showed significantly higher early metabolic activity (ratio of AUC(GIR) 0-6 h: BIAsp 50/BIAsp 30 = 1.28 [P IAsp/BIAsp 70 = 1.15 [P IAsp levels were significantly greater and late PK concentrations were significantly lower with increasing proportion of soluble IAsp. There are significant differences between the early and late PD and PK effects among BIAsp 30, 50, and 70 and IAsp that should allow tailored treatment with the convenience of prandial and basal insulin in each injection.

  9. TFE and Spt4/5 open and close the RNA polymerase clamp during the transcription cycle

    Science.gov (United States)

    Schulz, Sarah; Gietl, Andreas; Smollett, Katherine; Tinnefeld, Philip; Werner, Finn; Grohmann, Dina

    2016-01-01

    Transcription is an intrinsically dynamic process and requires the coordinated interplay of RNA polymerases (RNAPs) with nucleic acids and transcription factors. Classical structural biology techniques have revealed detailed snapshots of a subset of conformational states of the RNAP as they exist in crystals. A detailed view of the conformational space sampled by the RNAP and the molecular mechanisms of the basal transcription factors E (TFE) and Spt4/5 through conformational constraints has remained elusive. We monitored the conformational changes of the flexible clamp of the RNAP by combining a fluorescently labeled recombinant 12-subunit RNAP system with single-molecule FRET measurements. We measured and compared the distances across the DNA binding channel of the archaeal RNAP. Our results show that the transition of the closed to the open initiation complex, which occurs concomitant with DNA melting, is coordinated with an opening of the RNAP clamp that is stimulated by TFE. We show that the clamp in elongation complexes is modulated by the nontemplate strand and by the processivity factor Spt4/5, both of which stimulate transcription processivity. Taken together, our results reveal an intricate network of interactions within transcription complexes between RNAP, transcription factors, and nucleic acids that allosterically modulate the RNAP during the transcription cycle. PMID:26979960

  10. Craft Stick Beams

    Science.gov (United States)

    Karplus, Alan K.

    1996-01-01

    The objective of this exercise is to provide a phenomenological 'hands-on' experience that shows how geometry can affect the load carrying capacity of a material used in construction, how different materials have different failure characteristics, and how construction affects the performance of a composite material. This will be accomplished by building beams of a single material and composite beams of a mixture of materials (popsicle sticks, fiberboard sheets, and tongue depressors); testing these layered beams to determine how and where they fail; and based on the failure analysis, designing a layered beam that will fail in a predicted manner. The students will learn the effects of lamination, adhesion, and geometry in layered beam construction on beam strength and failure location.

  11. On the buckling of an elastic rotating beam

    DEFF Research Database (Denmark)

    Furta, Stanislaw D.; Kliem, Wolfhard; Pommer, Christian

    1997-01-01

    A nonlinear model is developed, which describes the buckling phenomena of an elastic beam clamped to the interior of a rotating wheel. We use a power series method to obtain an approximate expression of the buckling equation and compare this with previous results in the literature. The linearized...

  12. How the early voltage clamp studies of José del Castillo inform "modern" neuroscience.

    Science.gov (United States)

    Zottoli, Steven J

    2012-10-01

    The description of ionic currents that flow across the membrane of the squid giant axon during an action potential sparked an interest in determining whether there were similar currents in vertebrates. The preparation of choice was the node of Ranvier in single myelinated fibers in frog. José del Castillo spent 3 years on the United States mainland from 1956 to 1959. During that time, he collaborated with Jerome Y. Lettvin and John W. Moore. I discuss how these individuals met one another and some of their scientific discoveries using the voltage clamp to study squid giant axons and frog nodes. Much of this work was conducted at the Marine Biological Laboratory in Woods Hole, MA, and I attempt to convey a sense of the unique scientific "melting pot" that existed at the Marine Biological Laboratory and the broader effect that del Castillo had on "modern" neuroscience.

  13. Simulation and evaluation of efficiency of active clamp dual flyback inverter for photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Cernan, P. [Clayton Power Research and Development, Trencin (Slovakia); Dobrucky, B.; Sul, R. [Zilina Univ., Zilina (Slovakia)

    2010-03-09

    Dual flyback inverter (DFBI) is one of the preferred topologies for isolated low cost low power photovoltaic (PV) applications as it converts PV cells direct current (DC) voltage to output alternating current (AC) voltage using a single power stage. In order to reach the efficiency limits of this topology, it is important to understand the loss distribution of DFBI. This paper evaluated the efficiency of DFBI using computer simulation results of a Simetrix circuit simulator. The paper presented a circuit diagram of a dual flyback inverter with active clamp circuit and discussed the modelling and simulation of DFBI. The dimensioning of power stage components for DFBI simulation was presented. The results achieved by Simetrix simulation were also provided. The paper concluded with a discussion of silicon carbide diodes. It was concluded that the most important parameters for PV inverters are efficiency and cost. The size/power density of the inverter is not critical. 9 refs., 3 tabs., 6 figs.

  14. Delayed Umbilical Cord Clamping in the 21st Century: Indications for Practice.

    Science.gov (United States)

    Bayer, Kimberly

    2016-02-01

    Health care providers have debated the timing of umbilical cord clamping since the days of Aristotle. Delayed cord clamping was the mainstay of practice until about the 1950s when it was changed to immediate clamping on the basis of a series of blood volume studies combined with the introduction of active management of the third stage of labor. However, in recent years, several systematic reviews advise that delayed cord clamping should be used in all births for at least 30 to 60 seconds. The purpose of this article is to discuss the physiology of umbilical cord clamping, the potential benefits and adverse effects of delayed cord clamping, and how this affects the advanced practice nurse. A search of PubMed, Cochrane Reviews, and Clinical Key was used to find relevant research on the topic of umbilical cord clamping. Potential benefits of delayed cord clamping include decreased frequency of iron-deficiency anemia in the first year of life with improved neurodevelopmental outcomes in term infants, reduced need for blood transfusions, possible autologous transfusion of stem cells, and a decreased incidence of intraventricular hemorrhage. Apprehension exists regarding the feasibility of the practice as well as the potential hindrance of immediate resuscitation. There is a need to begin to look for populations for which delayed cord clamping can be implemented. Recommendations are inconsistent on the patient population and timing; therefore, further studies are needed to understand the multiple variables that affect timing of umbilical cord clamping.

  15. Electrostatic Interactions at the Dimer Interface Stabilize the E. coli β Sliding Clamp.

    Science.gov (United States)

    Purohit, Anirban; England, Jennifer K; Douma, Lauren G; Tondnevis, Farzaneh; Bloom, Linda B; Levitus, Marcia

    2017-08-22

    Sliding clamps are ring-shaped oligomeric proteins that encircle DNA and associate with DNA polymerases for processive DNA replication. The dimeric Escherichia coli β-clamp is closed in solution but must adopt an open conformation to be assembled onto DNA by a clamp loader. To determine what factors contribute to the stability of the dimer interfaces in the closed conformation and how clamp dynamics contribute to formation of the open conformation, we identified conditions that destabilized the dimer and measured the effects of these conditions on clamp dynamics. We characterized the role of electrostatic interactions in stabilizing the β-clamp interface. Increasing salt concentration results in decreased dimer stability and faster subunit dissociation kinetics. The equilibrium dissociation constant of the dimeric clamp varies with salt concentration as predicted by simple charge-screening models, indicating that charged amino acids contribute to the remarkable stability of the interface at physiological salt concentrations. Mutation of a charged residue at the interface (Arg-103) weakens the interface significantly, whereas effects are negligible when a hydrophilic (Ser-109) or a hydrophobic (Ile-305) amino acid is mutated instead. It has been suggested that clamp opening by the clamp loader takes advantage of spontaneous opening-closing fluctuations at the clamp's interface, but our time-resolved fluorescence and fluorescence correlation experiments rule out conformational fluctuations that lead to a significant fraction of open states. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  16. Clamped seismic metamaterials: ultra-low frequency stop bands

    Science.gov (United States)

    Achaoui, Y.; Antonakakis, T.; Brûlé, S.; Craster, R. V.; Enoch, S.; Guenneau, S.

    2017-06-01

    The regularity of earthquakes, their destructive power, and the nuisance of ground vibration in urban environments, all motivate designs of defence structures to lessen the impact of seismic and ground vibration waves on buildings. Low frequency waves, in the range 1-10 Hz for earthquakes and up to a few tens of Hz for vibrations generated by human activities, cause a large amount of damage, or inconvenience; depending on the geological conditions they can travel considerable distances and may match the resonant fundamental frequency of buildings. The ultimate aim of any seismic metamaterial, or any other seismic shield, is to protect over this entire range of frequencies; the long wavelengths involved, and low frequency, have meant this has been unachievable to date. Notably this is scalable and the effects also hold for smaller devices in ultrasonics. There are three approaches to obtaining shielding effects: bragg scattering, locally resonant sub-wavelength inclusions and zero-frequency stop-band media. The former two have been explored, but the latter has not and is examined here. Elastic flexural waves, applicable in the mechanical vibrations of thin elastic plates, can be designed to have a broad zero-frequency stop-band using a periodic array of very small clamped circles. Inspired by this experimental and theoretical observation, all be it in a situation far removed from seismic waves, we demonstrate that it is possible to achieve elastic surface (Rayleigh) wave reflectors at very large wavelengths in structured soils modelled as a fully elastic layer periodically clamped to bedrock. We identify zero frequency stop-bands that only exist in the limit of columns of concrete clamped at their base to the bedrock. In a realistic configuration of a sedimentary basin 15 m deep we observe a zero frequency stop-band covering a broad frequency range of 0-30 Hz.

  17. Analysis of motion during the breast clamping phase of mammography.

    Science.gov (United States)

    Ma, Wang Kei; McEntee, Mark F; Mercer, Claire; Kelly, Judith; Millington, Sara; Hogg, Peter

    2016-01-01

    To measure paddle motion during the clamping phase of a breast phantom for a range of machine/paddle combinations. A deformable breast phantom was used to simulate a female breast. 12 mammography machines from three manufacturers with 22 flexible and 20 fixed paddles were evaluated. Vertical motion at the paddle was measured using two calibrated linear potentiometers. For each paddle, the motion in millimetres was recorded every 0.5 s for 40 s, while the phantom was compressed with 80 N. Independent t-tests were used to determine differences in paddle motion between flexible and fixed, small and large, GE Senographe Essential (General Electric Medical Systems, Milwaukee, WI) and Hologic Selenia Dimensions paddles (Hologic, Bedford, MA). Paddle tilt in the medial-lateral plane for each machine/paddle combination was calculated. All machine/paddle combinations demonstrate highest levels of motion during the first 10 s of the clamping phase. The least motion is 0.17 ± 0.05 mm/10 s (n = 20) and the most motion is 0.51 ± 0.15 mm/10 s (n = 80). There is a statistical difference in paddle motion between fixed and flexible (p Hologic Selenia Dimensions paddles (p < 0.001). Paddle tilt in the medial-lateral plane is independent of time and varied from 0.04 ° to 0.69 °. All machine/paddle combinations exhibited motion and tilting, and the extent varied with machine and paddle sizes and types. This research suggests that image blurring will likely be clinically insignificant 4 s or more after the clamping phase commences.

  18. [Time of cord clamping and neonatal complications, a prospective study].

    Science.gov (United States)

    Rincón, D; Foguet, A; Rojas, M; Segarra, E; Sacristán, E; Teixidor, R; Ortega, A

    2014-09-01

    To assess the effects of early or late clamping of the umbilical cord in term newborns, assessing the levels of hemoglobin, hematocrit, and ferritin, and their correlation with some of the complications. A prospective study of healthy newborns at term or born by dystotic or eutocic delivery in our hospital between May 2009 until May 2010. Patients were assigned according to the time of clamping, group 1 (<60 seconds), group 2 (1 to<2 minutes), and group 3 (2 to 3 minutes). Laboratory tests were performed at birth and at 48 hours of life, assessing the levels of hemoglobin, hematocrit, ferritin, and bilirubin. The risk of polycythemia, respiratory distress syndrome, neonatal phototherapy or admission to the Intensive Care Unit and the hospital stay, were evaluated. A total of 242 patients were included: group 1 (g1=80), group 2 (g2=31) y group 3 (g3=131). The background maternal and neonatal characteristics were similar in all sets. The first test showed significant differences in ferritin levels in those infants with delayed clamping (g1: 111 mg/dl, g2: 125 mg/dl, g3: 173 mg/dl; p<0.01). In the second analysis the values of hemoglobin (g1: 17.3 g/dl, g2: 18.9 g/dl, g3: 19.2 g/dl; p<0.01), hematocrit (g1: 53.4%, g2: 58%, g3: 59%; p<0.01) and ferritin (g1: 254 mg/dl, g2: 254.7 mg/dl, g3: 313 mg/dl; p = 0.008) were statistically higher in this group. As regards complications, a significant increase was observed in the number of cases of polycythemia symptoms in group 3. The late cord clamping is associated with an increase in hematocrit, hemoglobin and ferritin at 48 hours of life, as well as an increased risk of polycythemia present with symptoms. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  19. Potassium Chloride Versus Voltage Clamp Contractures in Ventricular Muscle

    Science.gov (United States)

    Morad, M.; Reeck, S.; Rao, M.

    1981-01-01

    In frog ventricle, developed tension was markedly larger in response to depolarization caused by a voltage clamp step than to depolarization induced by high concentrations of potassium chloride. Measurement of extracellular potassium activity at the surface and at the depth of muscle during the development of contractures showed that the diffusion of potassium is much slower than the spread of depolarization through the cross section of muscle. These two observations suggest that competition between the depolarizing and the negative inotropic effects of an increase in the extracellular potassium ion concentration may determine the time course and magnitude of contractile tension in heart muscle.

  20. Failure-free survival following brachytherapy alone or external beam irradiation alone for T1-2 prostate tumors in 2222 patients: results from a single practice

    International Nuclear Information System (INIS)

    Brachman, David G.; Thomas, Theresa; Hilbe, Joseph; Beyer, David C.

    2000-01-01

    Purpose: To evaluate failure-free survival (FFS) for brachytherapy (BT) alone compared to external beam radiotherapy (EBRT) alone for Stage T1-2 Nx-No Mo patients over the same time period by a single community-based practice in the prostate-specific antigen (PSA) era. Materials and Methods: The database of Arizona Oncology Services (a multiphysician radiation oncology practice in the Phoenix metropolitan area) was reviewed for patients meeting the following criteria: (1) T1 or T2 Nx-No Mo prostate cancer; (2) no prior or concurrent therapy including hormones; (3) treatment period 12/88-12/95; and (4) treatment with either EBRT alone or BT alone ( 125 I or 103 Pd). This yielded 1527 EBRT and 695 BT patients; no patients meeting the above criteria were excluded from analysis. Median follow-up for EBRT patients was 41.3 months and, for BT patients, 51.3 months. Patients were not randomized to either therapy but rather received EBRT or BT based upon patient, treating, and/or referring physician preference. PSA failure was defined according to the ASTRO consensus guidelines. The median patient age was 74 years for both groups. Results: Failure-free survival at 5 years for EBRT and BT are 69% and 71%, respectively (p = 0.91). For T stage, no significant difference in FFS at 5 years is observed between EBRT and BT for either T1 (78% vs. 83%, p = 0.47) or T2 (67% vs. 67%, p = 0.89) tumors. Analysis by Gleason score shows superior outcomes for Gleason 8-10 lesions treated with EBRT vs. BT (5-year FFS 52% vs. 28%, p = 0.04); outcomes for lower grade lesions (Gleason 4-6) when analyzed by Gleason score alone do not significantly differ according to treatment received. Patients with initial PSA values of 10-20 ng/dL have an improved FFS with EBRT vs. BT at 5 years (70% vs. 53%, p = 0.001); outcomes for patients with initial PSA ranges of 0-4 ng/dL, of > 4-10 ng/dL, and > 20 ng/dL did not differ significantly by treatment received. FFS was also determined for presenting

  1. A Refined Zigzag Beam Theory for Composite and Sandwich Beams

    Science.gov (United States)

    Tessler, Alexander; Sciuva, Marco Di; Gherlone, Marco

    2009-01-01

    A new refined theory for laminated composite and sandwich beams that contains the kinematics of the Timoshenko Beam Theory as a proper baseline subset is presented. This variationally consistent theory is derived from the virtual work principle and employs a novel piecewise linear zigzag function that provides a more realistic representation of the deformation states of transverse-shear flexible beams than other similar theories. This new zigzag function is unique in that it vanishes at the top and bottom bounding surfaces of a beam. The formulation does not enforce continuity of the transverse shear stress across the beam s cross-section, yet is robust. Two major shortcomings that are inherent in the previous zigzag theories, shear-force inconsistency and difficulties in simulating clamped boundary conditions, and that have greatly limited the utility of these previous theories are discussed in detail. An approach that has successfully resolved these shortcomings is presented herein. Exact solutions for simply supported and cantilevered beams subjected to static loads are derived and the improved modelling capability of the new zigzag beam theory is demonstrated. In particular, extensive results for thick beams with highly heterogeneous material lay-ups are discussed and compared with corresponding results obtained from elasticity solutions, two other zigzag theories, and high-fidelity finite element analyses. Comparisons with the baseline Timoshenko Beam Theory are also presented. The comparisons clearly show the improved accuracy of the new, refined zigzag theory presented herein over similar existing theories. This new theory can be readily extended to plate and shell structures, and should be useful for obtaining relatively low-cost, accurate estimates of structural response needed to design an important class of high-performance aerospace structures.

  2. Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiation Therapy in the Treatment of Intermediate-Risk Prostate Cancer - Long Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Fabio L., E-mail: fabio.cury@muhc.mcgill.ca [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada); Duclos, Marie [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada); Aprikian, Armen [Department of Urology, McGill University Health Centre, Montreal, QC (Canada); Patrocinio, Horacio [Department of Medical Physics, McGill University Health Centre, Montreal, QC (Canada); Kassouf, Wassim [Department of Urology, McGill University Health Centre, Montreal, QC (Canada); Shenouda, George; Faria, Sergio; David, Marc; Souhami, Luis [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada)

    2012-03-15

    Purpose: We present the long-term results of a cohort of patients with intermediate-risk prostate cancer (PC) treated with single-fraction high-dose-rate brachytherapy (HDRB) combined with hypofractionated external beam radiation therapy (HypoRT). Methods and Materials: Patients were treated exclusively with HDRB and HypoRT. HDRB delivered a dose of 10 Gy to the prostate surface and HypoRT consisted of 50 Gy delivered in 20 daily fractions. The first 121 consecutive patients with a minimum of 2 years posttreatment follow-up were assessed for toxicity and disease control. Results: The median follow-up was 65.2 months. No acute Grade III or higher toxicity was seen. Late Grade II gastrointestinal toxicity was seen in 9 patients (7.4%) and Grade III in 2 (1.6%). Late Grade III genitourinary toxicity was seen in 2 patients (1.6%). After a 24-month follow-up, a rebiopsy was offered to the first 58 consecutively treated patients, and 44 patients agreed with the procedure. Negative biopsies were found in 40 patients (91%). The 5-year biochemical relapse-free survival rate was 90.7% (95% CI, 84.5-96.9%), with 13 patients presenting biochemical failure. Among them, 9 were diagnosed with distant metastasis. Prostate cancer-specific and overall survival rates at 5 years were 100% and 98.8% (95% CI, 96.4-100%), respectively. Conclusion: The combination of HDRB and HypoRT is well tolerated, with acceptable toxicity rates. Furthermore, results from rebiopsies revealed an encouraging rate of local control. These results confirm that the use of conformal RT techniques, adapted to specific biological tumor characteristics, have the potential to improve the therapeutic ratio in intermediate-risk PC patients.

  3. Simulating Matrix Crack and Delamination Interaction in a Clamped Tapered Beam

    Science.gov (United States)

    De Carvalho, N. V.; Seshadri, B. R.; Ratcliffe, J. G.; Mabson, G. E.; Deobald, L. R.

    2017-01-01

    Blind predictions were conducted to validate a discrete crack methodology based on the Floating Node Method to simulate matrix-crack/delamination interaction. The main novel aspects of the approach are: (1) the implementation of the floating node method via an 'extended interface element' to represent delaminations, matrix-cracks and their interaction, (2) application of directional cohesive elements to infer overall delamination direction, and (3) use of delamination direction and stress state at the delamination front to determine migration onset. Overall, good agreement was obtained between simulations and experiments. However, the validation exercise revealed the strong dependence of the simulation of matrix-crack/delamination interaction on the strength data (in this case transverse interlaminar strength, YT) used within the cohesive zone approach applied in this work. This strength value, YT, is itself dependent on the test geometry from which the strength measurement is taken. Thus, choosing an appropriate strength value becomes an ad-hoc step. As a consequence, further work is needed to adequately characterize and assess the accuracy and adequacy of cohesive zone approaches to model small crack growth and crack onset. Additionally, often when simulating damage progression with cohesive zone elements, the strength is lowered while keeping the fracture toughness constant to enable the use of coarser meshes. Results from the present study suggest that this approach is not recommended for any problem involving crack initiation, small crack growth or multiple crack interaction.

  4. Load-deflection characteristics of small-bore insulated-pipe clamps

    International Nuclear Information System (INIS)

    Severud, L.K.; Clark, G.L.

    1981-12-01

    The special insulated clamps used on both FFTF and CRBR piping utilize a Belleville spring arrangement to compensate for pipe thermal expansion. Analysis indicates that this produces a non-linear, directionally sensitive clamp spring rate. Since these spring rates influence the seismic response of a supported piping system, it was deemed necessary to evaluate them further by test. This has been accomplished for the FFTF clamps. A more standard insulated pipe clamp, which does not incorporate Belleville springs to accommodate thermal expansion, was also tested. This type clamp is simple in design, and economically attractive. It may have wide application prospects for use in LMFBR small bore auxiliary piping operating at temperatures below 427 0 C. Load deflection tests were conducted on 2.54 CM and 7.62 CM diameter samples of these commercial clamps

  5. Parametric Study of the current limit within a single driver-scale transport beam line of an induction Linac for Heavy Ion Fusion

    International Nuclear Information System (INIS)

    Prost, Lionel Robert

    2007-01-01

    The High Current Experiment (HCX) at Lawrence Berkeley National Laboratory is part of the US program that explores heavy-ion beam as the driver option for fusion energy production in an Inertial Fusion Energy (IFE) plant. The HCX is a beam transport experiment at a scale representative of the low-energy end of an induction linear accelerator driver. The primary mission of this experiment is to investigate aperture fill factors acceptable for the transport of space-charge-dominated heavy-ion beams at high intensity (line charge density ∼0.2 (micro)C/m) over long pulse durations (4 (micro)s) in alternating gradient focusing lattices of electrostatic or magnetic quadrupoles. This experiment is testing transport issues resulting from nonlinear space-charge effects and collective modes, beam centroid alignment and steering, envelope matching, image charges and focusing field nonlinearities, halo and, electron and gas cloud effects. We present the results for a coasting 1 MeV K + ion beam transported through ten electrostatic quadrupoles. The measurements cover two different fill factor studies (60% and 80% of the clear aperture radius) for which the transverse phase-space of the beam was characterized in detail, along with beam energy measurements and the first halo measurements. Electrostatic quadrupole transport at high beam fill factor (∼80%) is achieved with acceptable emittance growth and beam loss. We achieved good envelope control, and re-matching may only be needed every ten lattice periods (at 80% fill factor) in a longer lattice of similar design. We also show that understanding and controlling the time dependence of the envelope parameters is critical to achieving high fill factors, notably because of the injector and matching section dynamics

  6. Parametic Study of the current limit within a single driver-scaletransport beam line of an induction Linac for Heavy Ion Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Prost, Lionel Robert [Univ. of California, Berkeley, CA (United States)

    2004-01-01

    The High Current Experiment (HCX) at Lawrence Berkeley National Laboratory is part of the US program that explores heavy-ion beam as the driver option for fusion energy production in an Inertial Fusion Energy (IFE) plant. The HCX is a beam transport experiment at a scale representative of the low-energy end of an induction linear accelerator driver. The primary mission of this experiment is to investigate aperture fill factors acceptable for the transport of space-charge-dominated heavy-ion beams at high intensity (line charge density ~0.2 μC/m) over long pulse durations (4 μs) in alternating gradient focusing lattices of electrostatic or magnetic quadrupoles. This experiment is testing transport issues resulting from nonlinear space-charge effects and collective modes, beam centroid alignment and steering, envelope matching, image charges and focusing field nonlinearities, halo and, electron and gas cloud effects. We present the results for a coasting 1 MeV K+ ion beam transported through ten electrostatic quadrupoles. The measurements cover two different fill factor studies (60% and 80% of the clear aperture radius) for which the transverse phase-space of the beam was characterized in detail, along with beam energy measurements and the first halo measurements. Electrostatic quadrupole transport at high beam fill factor (~80%) is achieved with acceptable emittance growth and beam loss. We achieved good envelope control, and re-matching may only be needed every ten lattice periods (at 80% fill factor) in a longer lattice of similar design. We also show that understanding and controlling the time dependence of the envelope parameters is critical to achieving high fill factors, notably because of the injector and matching section dynamics.

  7. Coherent beam-beam effects

    International Nuclear Information System (INIS)

    Chao, A.W.

    1992-01-01

    There are two physical pictures that describe the beam-beam interaction in a storage ring collider: The weak-strong and the strong-strong pictures. Both pictures play a role in determining the beam-beam behavior. This review addresses only the strong-strong picture. The corresponding beam dynamical effects are referred to as the coherent beam-beam effects. Some basic knowledge of the weak-strong picture is assumed. To be specific, two beams of opposite charges are considered. (orig.)

  8. Renal function is the same 6 months after robot-assisted partial nephrectomy regardless of clamp technique: analysis of outcomes for off-clamp, selective arterial clamp and main artery clamp techniques, with a minimum follow-up of 1 year.

    Science.gov (United States)

    Komninos, Christos; Shin, Tae Young; Tuliao, Patrick; Han, Woong Kyu; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho

    2015-06-01

    To compare the renal functional outcomes, with >1 year of follow-up, of patients who underwent robot-assisted partial nephrectomy (RAPN) performed with different clamping techniques. The peri-operative data of patients undergoing RAPN performed with different clamping techniques were retrospectively analysed (group 1: off-clamp, n = 23; group 2: selective clamp, n = 25; group 3: main artery clamp, n = 114). The main outcome measures were postoperative serum creatinine level, estimated glomerular filtration rate (eGFR) and percentage change in eGFR, the data for which were collected at periodic intervals during the first 12 months and annually thereafter, in addition to late eGFR value. Only patients with >1 year of follow-up were included in the analysis. The baseline characteristics of groups 2 and 3 were similar, while patients in group 1 had smaller sized tumours and lower tumour complexity. The median follow-up periods were 45 (group 1), 20 (group 2) and 47 (group 3) months. The median clamping times were 24.8 min in the main artery clamp and 18 min in the selective artery clamp groups. Group 2 had greater median blood loss volume (100 vs 500 vs 200 mL for groups 1, 2 and 3, respectively; P clamp procedure and tumour complexity score were predictive of normal renal function 7 days after surgery, while only baseline eGFR and age could predict it 1 year postoperatively. Off-clamp and selective artery clamp techniques result in superior short-term renal functional outcomes compared with the main artery clamp approach; however, after the 6th postoperative month, there were no significant differences regarding the functional outcome among the above surgical techniques, as long as the warm ischaemia time was 20-30 min. © 2014 The Authors BJU International © 2014 BJU International.

  9. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2011-11-01

    Full Text Available zones capable of introducing a phase shift of zero or p on the alternately out of phase rings of the TEMp0 beams into a unified phase and then focusing the rectified beam to generate a high resolution beam which has a Gaussian beam intensity distribution...

  10. Mechanism of ATP-driven PCNA clamp loading by S. cerevisiae RFC.

    Science.gov (United States)

    Chen, Siying; Levin, Mikhail K; Sakato, Miho; Zhou, Yayan; Hingorani, Manju M

    2009-05-08

    Circular clamps tether polymerases to DNA, serving as essential processivity factors in genome replication, and function in other critical cellular processes as well. Clamp loaders catalyze clamp assembly onto DNA, and the question of how these proteins construct a topological link between a clamp and DNA, especially the mechanism by which ATP is utilized for the task, remains open. Here we describe pre-steady-state analysis of ATP hydrolysis, proliferating cell nuclear antigen (PCNA) clamp opening, and DNA binding by Saccharomyces cerevisiae replication factor C (RFC), and present the first kinetic model of a eukaryotic clamp-loading reaction validated by global data analysis. ATP binding to multiple RFC subunits initiates a slow conformational change in the clamp loader, enabling it to bind and open PCNA and to bind DNA as well. PCNA opening locks RFC into an active state, and the resulting RFC.ATP.PCNA((open)) intermediate is ready for the entry of DNA into the clamp. DNA binding commits RFC to ATP hydrolysis, which is followed by PCNA closure and PCNA.DNA release. This model enables quantitative understanding of the multistep mechanism of a eukaryotic clamp loader and furthermore facilitates comparative analysis of loaders from diverse organisms.

  11. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... analyzed with loads connected to △. But it will be further researched in the future. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping three-level inverter is briefly presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS...

  12. Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy

    International Nuclear Information System (INIS)

    Xu, Yi; Shao, Pengfei; Zhu, Xiaomei; Lv, Qiang; Liu, Wangyan; Xu, Hai; Zhu, Yinsu; Yang, Guangyu; Tang, Lijun; Yin, Changjun

    2013-01-01

    Aim: To evaluate the effectiveness of three-dimensional (3D) renal computed tomography angiography (CTA) in guiding segmental renal artery clamping during laparoscopic partial nephrectomy (LPN). Materials and methods: Forty-three patients with renal tumours undergoing renal CTA before LPN were retrospectively enrolled in this study. 3D arteriogram reconstructed images were created to identify the renal tumour-supplying arteries. The number and location of these targeted vessels were annotated on 3D images preoperatively and compared with the clamped vessels during LPN. The consistency between target vessels annotated at CTA and clamped arteries at LPN was compared both using a patient-based analysis and vessel-based analysis. The χ 2 test was applied to analyse the influence of tumour size, location, and growth pattern on the number of clamped segmental renal branches. Results: On patient-based analysis, the number of targeted vessels was consistent with the clamped vessels during LPN in 33 of 43 patients. On vessel-based analysis, 56 of 65 target vessels annotated at CTA were clamped during LPN. More segmental renal branches (p = 0.04) were clamped in patients with tumours of larger size. Tumour location and growth pattern had no association with the number of clamped segmental branches during LPN. Conclusion: High-quality CTA images and 3D reconstruction images can detect detailed information of tumour-supplying arteries to renal tumours. 3D renal CTA is an effective way to guide segmental renal artery clamping during LPN

  13. How does clamping pressure influence actuation performance of soft ionic polymer–metal composites?

    International Nuclear Information System (INIS)

    Moeinkhah, Hossein; Jung, Jin-Young; Jeon, Jin-Han; Park, K C; Oh, Il-Kwon; Akbarzadeh, Ali; Rezaeepazhand, Jalil

    2013-01-01

    The effect of clamping pressure on the actuation performance of ionic polymer–metal composite (IPMC) actuators is newly investigated by carefully considering changes of mechanical stiffness and electrical resistance due to the interfacial contacts between the IPMC and clamping devices. During the clamping process, the soft ionic exchangeable polymer membrane will be squeezed along the thickness direction in the clamping area, resulting in a change of the mechanical stiffness of the cantilevered IPMCs. Also, the electrical contact resistance between two electrodes of the IPMC and the clamping device will be greatly changed according to the change of clamping pressures. Present experimental results show that clamping pressures between the IPMC and the clamping device will strongly affect the actuation performance of the IPMC actuators. An exact electro-mechanical model is developed to fully describe dynamics of the IPMC actuators by considering structural damping, hydrodynamic loading and electro-mechanical force. This study shows that there exists an optimal clamping pressure to obtain the largest bending deformation of the IPMC actuator because of a trade-off between mechanical stiffness and electrical contact resistance. (paper)

  14. Cost-Effectiveness Analysis of Single Fraction of Stereotactic Body Radiation Therapy Compared With Single Fraction of External Beam Radiation Therapy for Palliation of Vertebral Bone Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hayeon, E-mail: kimh2@upmc.edu [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Rajagopalan, Malolan S.; Beriwal, Sushil; Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Smith, Kenneth J. [Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania (United States)

    2015-03-01

    Purpose: Stereotactic body radiation therapy (SBRT) has been proposed for the palliation of painful vertebral bone metastases because higher radiation doses may result in superior and more durable pain control. A phase III clinical trial (Radiation Therapy Oncology Group 0631) comparing single fraction SBRT with single fraction external beam radiation therapy (EBRT) in palliative treatment of painful vertebral bone metastases is now ongoing. We performed a cost-effectiveness analysis to compare these strategies. Methods and Materials: A Markov model, using a 1-month cycle over a lifetime horizon, was developed to compare the cost-effectiveness of SBRT (16 or 18 Gy in 1 fraction) with that of 8 Gy in 1 fraction of EBRT. Transition probabilities, quality of life utilities, and costs associated with SBRT and EBRT were captured in the model. Costs were based on Medicare reimbursement in 2014. Strategies were compared using the incremental cost-effectiveness ratio (ICER), and effectiveness was measured in quality-adjusted life years (QALYs). To account for uncertainty, 1-way, 2-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay (WTP) threshold of $100,000 per QALY gained. Results: Base case pain relief after the treatment was assumed as 20% higher in SBRT. Base case treatment costs for SBRT and EBRT were $9000 and $1087, respectively. In the base case analysis, SBRT resulted in an ICER of $124,552 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of the utility of unrelieved pain; the utility of relieved pain after initial treatment and median survival were also sensitive to variation. If median survival is ≥11 months, SBRT cost <$100,000 per QALY gained. Conclusion: SBRT for palliation of vertebral bone metastases is not cost-effective compared with EBRT at a $100,000 per QALY gained WTP threshold. However, if median survival is ≥11 months, SBRT costs ≤$100

  15. Hypoglycaemia and QT interval prolongation in type 1 diabetes - bridging the gap between clamp studies and spontaneous episodes

    DEFF Research Database (Denmark)

    Christensen, Toke F.; Cichosz, Simon Lebech; Tarnow, Lise

    2014-01-01

    AIMS: We propose a study design with controlled hypoglycaemia induced by subcutaneous injection of insulin and matched control episodes to bridge the gap between clamp studies and studies of spontaneous hypoglycaemia. The observed prolongation of the heart rate corrected QT interval (QTc) during...... hypoglycaemia varies greatly between studies. METHODS: We studied ten adults with type 1 diabetes (age 41±15years) without cardiovascular disease or neuropathy. Single-blinded hypoglycaemia was induced by a subcutaneous insulin bolus followed by a control episode on two occasions separated by 4weeks. QT...

  16. Generalised Predictive Control of a 12-bus Network Using Neutral-Point Clamped Voltage Source Converter UPFC

    OpenAIRE

    Zhang, L; Kokkinakis, M; Chong, BVP

    2014-01-01

    The paper presents the application of a UPFC to a case study of a 12-bus high power network. The UPFC shunt converter employs 8 3-level Neutral Point Clamped (NPC) voltage source converters (VSC) and 12 single-phase three-winding phase shifting transformers (PST), generating a 48-pulse output voltage. The 3-phase H-bridge series converter shares the same dc-link with the shunt one. The novel feature of this work lies in the use of a model-based generalised predictive current control law to th...

  17. Orthogonal image pairs coupled with OSMS for noncoplanar beam angle, intracranial, single-isocenter, SRS treatments with multiple targets on the Varian Edge radiosurgery system

    Directory of Open Access Journals (Sweden)

    Jasmine A. Oliver, PhD

    2017-07-01

    Conclusion: Based on our study, CR-induced shifts with the Varian Edge radiosurgery system will not produce noticeable dosimetric effects for SRS treatments. Thus, replacing cone beam CT with orthogonal kV/kV pairs coupled with OSMS at the treatment couch angle could reduce the number of cone beam CT scans that are acquired during a standard SRS treatment while providing an accurate and safe treatment with negligible dosimetric effects on the treatment plan.

  18. Maximum natural frequencies of polymer composite micro-beams by optimum distribution of carbon nanotubes

    International Nuclear Information System (INIS)

    Rokni, Hossein; Milani, Abbas S.; Seethaler, Rudolf J.

    2011-01-01

    Highlights: → Optimum distributions of MWCNTs within the polymer micro-beams are obtained. → Natural frequencies of nanocomposite beam enhance if its root portion is reinforced with CNTs. → Adding MWCNTs to pure polymer micro-beams has an insignificant effect on mode shapes. → Fundamental frequency value is improved by 12.6-15.9% for various boundary conditions. → New CNT dispersion equations are suggested based on the optimum CNT loading pattern. -- Abstract: Optimum distribution of multi-walled carbon nanotubes (MWCNTs) within a polymer composite micro-beam is sought to achieve its highest natural frequencies given a weight percent (wt.%) of MWCNTs. To this end, the micro-beam is divided into ten segments which are perfectly bonded to their neighbors. Each segment is made of low-viscosity, thermosetting polyester epoxy/amine resin LY-5052 and is reinforced by MWCNTs. A computer program, written in the Python programming language, is compiled with ABAQUS to generate a three-dimensional (3D) finite element (FE) model of the micro-beam and subsequently to evaluate an optimum CNT distribution under various vibration modes and boundary conditions. The influence of uniform and optimum MWCNT distributions on the natural frequencies, mode shapes and equivalent stiffness of the micro-beams is investigated and the results are compared with those of the pure polymer micro-beam. Subsequently, after acquiring the optimum distribution of the MWCNTs, two new CNT dispersion functions are proposed for maximizing fundamental frequencies of the clamped-free and clamped-clamped micro-beams. The results of the FE analysis reveal that the optimal reinforcement distribution pattern significantly depends on vibration mode shapes, particularly the micro-beam curvature under each mode. It is observed that fundamental frequencies of clamped-free, clamped-guided and clamped-clamped micro-beams are enhanced up to 15.9%, 13.1% and 12.6%, respectively, by choosing optimum MWCNT

  19. Early clamp release during laparoscopic partial nephrectomy: Implications for preservation of renal function.

    Science.gov (United States)

    Campbell, Jeffrey; Chan, Garson; Luke, Patrick P

    2017-07-01

    Intraoperative warm ischemic time (WIT), associated with hilar clamping during partial nephrectomy (PN), is an established modifiable risk factor for renal dysfunction. We assessed early clamp release (ECR) as a strategy to reduce WIT and assess its impact on renal function and bleeding. We retrospectively assessed patients who underwent minimally invasive PN by a single surgeon at our centre since December 2011. Comparing the standard technique to an ECR modification, WIT, complications, change in estimated glomerular filtration rate (eGFR), and change in differential function as demonstrated by MAG-3 nuclear renography were assessed. Followup blood work and renograms were performed at 6-12 weeks postoperatively and compared to baseline in 70 patients (35 ECR: 35 control). The ECR and control groups were similar in age, sex, and tumour size, with only patient weight being higher in the ECR group (91.6 vs. 81.6 kg; p<0.05). WIT was significantly lower in ECR group compared to control (18.8 vs. 31.5 minutes; p<0.05). Although there was no significant difference in change from baseline eGFR in the early postoperative period (Day 3) or in followup (6-12 weeks), the control group had a significantly greater loss of ipsilateral renal function from baseline compared to the ECR group (9 vs. 4% change; p<0.05). Blood loss and complication rate were similar between groups. The ECR technique offers a safe, reproducible alternative that reduces WIT during laparoscopic PN. ECR demonstrates a reduction in overall ipsilateral renal dysfunction, without increasing complication or intraoperative bleeding risk.

  20. A patch-clamp ASIC for nanopore-based DNA analysis.

    Science.gov (United States)

    Kim, Jungsuk; Maitra, Raj; Pedrotti, Kenneth D; Dunbar, William B

    2013-06-01

    In this paper, a fully integrated high-sensitivity patch-clamp system is proposed for single-molecule deoxyribonucleic acid (DNA) analysis using a nanopore sensor. This system is composed of two main blocks for amplification and compensation. The amplification block is composed of three stages: 1) a headstage, 2) a voltage-gain difference amplifier, and 3) a track-and-hold circuit, that amplify a minute ionic current variation sensed by the nanopore while the compensation block avoids the headstage saturation caused by the input parasitic capacitances during sensing. By employing design techniques novel for this application, such as an instrumentation--amplifier topology and a compensation switch, we minimize the deleterious effects of the input-offset voltage and the input parasitic capacitances while attaining hardware simplicity. This system is fabricated in a 0.35 μm 4M2P CMOS process and is demonstrated using an α-hemolysin protein nanopore for detection of individual molecules of single-stranded DNA that pass through the 1.5 nm-diameter pore. In future work, the refined system will functionalize single and multiple solid-state nanopores formed in integrated microfluidic devices for advanced DNA analysis, in scientific and diagnostic applications.

  1. Comparison of single junction AlGaInP and GaInP solar cells grown by molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, T; Tomasulo, S; Lang, JR; Lee, ML

    2015-03-07

    We have investigated similar to 2.0 eV (AlxGa1-x)(0.51)In0.49P and similar to 1.9 eV Ga0.51In0.49P single junction solar cells grown on both on-axis and misoriented GaAs substrates by molecular beam epitaxy (MBE). Although lattice-matched (AlxGa1-x)(0.51)In0.49P solar cells are highly attractive for space and concentrator photovoltaics, there have been few reports on the MBE growth of such cells. In this work, we demonstrate open circuit voltages (V-oc) ranging from 1.29 to 1.30 V for Ga0.51In0.49P cells, and 1.35-1.37 V for (AlxGa1-x)(0.51)In0.49P cells. Growth on misoriented substrates enabled the bandgap-voltage offset (W-oc = E-g/q - V-oc) of Ga0.51In0.49P cells to decrease from similar to 575 mV to similar to 565 mV, while that of (AlxGa1-x)(0.51)In0.49P cells remained nearly constant at 620 mV. The constant Woc as a function of substrate offcut for (AlxGa1-x)(0.51)In0.49P implies greater losses from non-radiative recombination compared with the Ga0.51In0.49P devices. In addition to larger Woc values, the (AlxGa1-x)(0.51)In0.49P cells exhibited significantly lower internal quantum efficiency (IQE) values than Ga0.51In0.49P cells due to recombination at the emitter/window layer interface. A thin emitter design is experimentally shown to be highly effective in improving IQE, particularly at short wavelengths. Our work shows that with further optimization of both cell structure and growth conditions, MBE-grown (AlxGa1-x)(0.51)In0.49P will be a promising wide-bandgap candidate material for high-efficiency, lattice-matched multi-junction solar cells. (C) 2015 AIP Publishing LLC.

  2. Stability and vibrations control of a stepped beam using piezoelectric actuation

    Directory of Open Access Journals (Sweden)

    Kuliński Krzysztof

    2018-01-01

    Full Text Available The objects of this studies are the stability and transversal vibrations of the system composed of three segments, where in the centre part of the system two piezoelectric patches are perfectly bonded to the top and bottom surface of the host beam. The system is kinematically loaded as a result of prescribed displacement of one or both end supports. For the analysis purposes three different beam end supports have been taken into consideration, which prevent longitudinal displacements i.e. clamped-clamped, clamped-pinned and pinned-pinned. This type of beam loading not only affect its natural vibration frequencies but also the system’s stability. By introducing the electric field to the piezo patches, depending on its vector direction, in-plane stretching or compressive residual force may be induced. Presented results show that piezo actuation can significantly modify both the critical buckling force and the vibration frequency.

  3. Clamped end conditions and cross section deformation in the finite element absolute nodal coordinate formulation

    International Nuclear Information System (INIS)

    Hussein, Bassam A.; Weed, David; Shabana, Ahmed A.

    2009-01-01

    In the finite element absolute nodal coordinate formulation (ANCF), the elimination of the relative translations and rotations at a point does not necessarily define a fully clamped joint, particularly in the case of fully parameterized ANCF finite elements that allow for the deformation of the cross section. In this investigation, the formulations and results of two different sets of clamped end conditions that define two different joints are compared. The first joint, called the partially clamped joint, eliminates only the translations and rotations at a point on the cross section. The second joint, called the fully clamped joint, eliminates all the translation, rotation and deformation degrees of freedom at a point on the cross section. The kinematic equations that define the partially and fully clamped joints are developed, and the dynamic equations used in the comparative numerical study presented in this paper are shown. As discussed in this investigation, the fully clamped joint does not allow for the deformation of the cross section at the joint node since the gradient vectors remain orthogonal unit vectors. The partially clamped joint, on the other hand, allows for the deformation of the cross section. Nanson's formula is used as a measure of the deformation of the cross section in the case of the partially clamped joint. A very flexible pendulum that has a rigid body attached to its free end is used to compare the results of the partially and fully clamped joints. The numerical results obtained using this very flexible pendulum example show that, while the type of joint (partially or fully clamped) does not significantly affect the gross reference motion of the system, there are fundamental differences between the two joints since the partially clamped joint allows for the cross section deformations at the joint node

  4. Renal Vascular Clamp Placement: A Potential Cause of Incomplete Hilar Control during Partial Nephrectomy.

    Science.gov (United States)

    Tryon, David; Myklak, Kristene; Alsyouf, Muhannad; Conceicao, Carol; Peplinski, Brandon; Arenas, Javier L; Faaborg, Daniel; Ruckle, Herbert C; Baldwin, D Duane

    2016-03-01

    Previous benchtop studies have shown that robotic bulldog clamps provide incomplete vascular control of a Penrose drain. We determined the efficacy of robotic and laparoscopic bulldog clamps to ensure hemostasis on the human renal artery. The effect of clamp position on vascular control was also examined. Fresh human cadaveric renal arteries were used to determine the leak point pressure of 7 bulldog clamps from a total of 3 manufacturers. Five trials were performed per clamp at 4 locations, including the fulcrum, proximal, middle and distal positions. Comparison was done using the Kruskal-Wallis test with p clamps leaked at a pressure less than 215 mm Hg when applied at the proximal, middle or distal position. In general leak point pressure decreased as the artery was positioned more distal along the clamp. The exception was when the vessel was placed at the fulcrum position. At that position 80% to 100% of trials with the Klein laparoscopic, 100% with the Klein robotic (Klein Robotic, San Antonio, Texas) and 60% to 80% with the Scanlan robotic (Scanlan International, Saint Paul, Minnesota) clamp leaked at pressure below 215 mm Hg. Each vascular clamp adequately occluded flow at physiological pressure when placed at the proximal, middle or distal position. Furthermore, these results demonstrate that there is leakage at physiological pressure when the artery is placed at the fulcrum of certain clamp types. These results suggest that applying a bulldog clamp at the fulcrum could potentially lead to inadequate vessel occlusion and intraoperative bleeding. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Beam-beam and impedance

    CERN Document Server

    White, S.

    2014-07-17

    As two counter-rotating beams interact they can give rise to coherent dipole modes. Under the influence of impedance these coherent beam-beam modes can couple to higher order head-tail modes and lead to strong instabilities. A fully self-consistent approach including beam-beam and impedance was used to characterize this new coupled mode instability and study possible cures such as a transverse damper and high chromaticity.

  6. Conserved residues in the delta subunit help the E. coli clamp loader, gamma complex, target primer-template DNA for clamp assembly.

    Science.gov (United States)

    Chen, Siying; Coman, Maria Magdalena; Sakato, Miho; O'Donnell, Michael; Hingorani, Manju M

    2008-06-01

    The Escherichia coli clamp loader, gamma complex (gamma(3)deltadelta'lambdapsi), catalyzes ATP-driven assembly of beta clamps onto primer-template DNA (p/tDNA), enabling processive replication. The mechanism by which gamma complex targets p/tDNA for clamp assembly is not resolved. According to previous studies, charged/polar amino acids inside the clamp loader chamber interact with the double-stranded (ds) portion of p/tDNA. We find that dsDNA, not ssDNA, can trigger a burst of ATP hydrolysis by gamma complex and clamp assembly, but only at far higher concentrations than p/tDNA. Thus, contact between gamma complex and dsDNA is necessary and sufficient, but not optimal, for the reaction, and additional contacts with p/tDNA likely facilitate its selection as the optimal substrate for clamp assembly. We investigated whether a conserved sequence-HRVW(279)QNRR--in delta subunit contributes to such interactions, since Tryptophan-279 specifically cross-links to the primer-template junction. Mutation of delta-W279 weakens gamma complex binding to p/tDNA, hampering its ability to load clamps and promote proccessive DNA replication, and additional mutations in the sequence (delta-R277, delta-R283) worsen the interaction. These data reveal a novel location in the C-terminal domain of the E. coli clamp loader that contributes to DNA binding and helps define p/tDNA as the preferred substrate for the reaction.

  7. Crystal structure of DNA polymerase III β sliding clamp from Mycobacterium tuberculosis.

    Science.gov (United States)

    Gui, Wen-Jun; Lin, Shi-Qiang; Chen, Yuan-Yuan; Zhang, Xian-En; Bi, Li-Jun; Jiang, Tao

    2011-02-11

    The sliding clamp is a key component of DNA polymerase III (Pol III) required for genome replication. It is known to function with diverse DNA repair proteins and cell cycle-control proteins, making it a potential drug target. To extend our understanding of the structure/function relationship of the sliding clamp, we solved the crystal structure of the sliding clamp from Mycobacterium tuberculosis (M. tuberculosis), a human pathogen that causes most cases of tuberculosis (TB). The sliding clamp from M. tuberculosis forms a ring-shaped head-to-tail dimer with three domains per subunit. Each domain contains two α helices in the inner ring that lie against two β sheets in the outer ring. Previous studies have indicated that many Escherichia coli clamp-binding proteins have a conserved LF sequence, which is critical for binding to the hydrophobic region of the sliding clamp. Here, we analyzed the binding affinities of the M. tuberculosis sliding clamp and peptides derived from the α and δ subunits of Pol III, which indicated that the LF motif also plays an important role in the binding of the α and δ subunits to the sliding clamp of M. tuberculosis. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. A structural and mechanistic study of π-clamp-mediated cysteine perfluoroarylation.

    Science.gov (United States)

    Dai, Peng; Williams, Jonathan K; Zhang, Chi; Welborn, Matthew; Shepherd, James J; Zhu, Tianyu; Van Voorhis, Troy; Hong, Mei; Pentelute, Bradley L

    2017-08-11

    Natural enzymes use local environments to tune the reactivity of amino acid side chains. In searching for small peptides with similar properties, we discovered a four-residue π-clamp motif (Phe-Cys-Pro-Phe) for regio- and chemoselective arylation of cysteine in ribosomally produced proteins. Here we report mutational, computational, and structural findings directed toward elucidating the molecular factors that drive π-clamp-mediated arylation. We show the significance of a trans conformation prolyl amide bond for the π-clamp reactivity. The π-clamp cysteine arylation reaction enthalpy of activation (ΔH ‡ ) is significantly lower than a non-π-clamp cysteine. Solid-state NMR chemical shifts indicate the prolyl amide bond in the π-clamp motif adopts a 1:1 ratio of the cis and trans conformation, while in the reaction product Pro3 was exclusively in trans. In two structural models of the perfluoroarylated product, distinct interactions at 4.7 Å between Phe1 side chain and perfluoroaryl electrophile moiety are observed. Further, solution 19 F NMR and isothermal titration calorimetry measurements suggest interactions between hydrophobic side chains in a π-clamp mutant and the perfluoroaryl probe. These studies led us to design a π-clamp mutant with an 85-fold rate enhancement. These findings will guide us toward the discovery of small reactive peptides to facilitate abiotic chemistry in water.

  9. Field calculations, single-particle tracking, and beam dynamics with space charge in the electron lens for the Fermilab Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Noll, Daniel [Goethe Univ., Frankfurt (Germany); Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-11-17

    An electron lens is planned for the Fermilab Integrable Optics Test Accelerator as a nonlinear element for integrable dynamics, as an electron cooler, and as an electron trap to study space-charge compensation in rings. We present the main design principles and constraints for nonlinear integrable optics. A magnetic configuration of the solenoids and of the toroidal section is laid out. Singleparticle tracking is used to optimize the electron path. Electron beam dynamics at high intensity is calculated with a particle-in-cell code to estimate current limits, profile distortions, and the effects on the circulating beam. In the conclusions, we summarize the main findings and list directions for further work.

  10. Single- and multi-foils {sup 27}Al(p,3pn){sup 24}Na activation technique for monitoring the intensity of high-energy beams

    Energy Technology Data Exchange (ETDEWEB)

    Curioni, A. [CERN, 1211 Geneva 23 (Switzerland); Politecnico di Milano, Department of Energy, 20156 Milan (Italy); Froeschl, R.; Glaser, M. [CERN, 1211 Geneva 23 (Switzerland); Iliopoulou, E. [CERN, 1211 Geneva 23 (Switzerland); Medical Physics Laboratory, School of Medicine, Aristotle University of Thessaloniki (Greece); La Torre, F.P. [CERN, 1211 Geneva 23 (Switzerland); Pozzi, F., E-mail: fabio.pozzi@cern.ch [CERN, 1211 Geneva 23 (Switzerland); Ravotti, F.; Silari, M. [CERN, 1211 Geneva 23 (Switzerland)

    2017-06-21

    This paper discusses an experimental study of the spallation reaction {sup 27}Al(p,3pn){sup 24}Na in Al foils exposed to 24 GeV c{sup −1} protons, in the context of monitoring the intensity of multi-GeV proton beams through foil activation techniques. Since this reaction is sensitive to secondary neutrons and other energetic secondary hadrons, it is important to evaluate the impact of the foil thickness on the calculation of the beam intensity. This effect is determined experimentally using a stack of Al foils of varying thickness. The experimental results are then compared to Monte Carlo simulations.

  11. Electron beam based transversal profile measurements of intense ion beams; Elektronenstrahl-Diagnostik zur Bestimmung vom transversalen Profil intensiver Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    El Moussati, Said

    2014-11-03

    application range of the EBI diagnostic method and to benchmark the theoretical model. To achieve this goal a code has been developed in the programming language Python. Different charge distributions were considered and the simulation results have been compared with the theoretical model. The numerical investigations have shown a very good agreement with the theoretical model for deflection angles up to 20 mrad. This value defines the limit for the applicability of the theoretical model. Moreover, the magnetic field of the ion beam has also been taken into acount in the simulations. The results show that at high ion beam currents - starting at about 1 A - the electrons experience a non-negligible displacement along the ion beam axis, which has to be taken into consideration in experiments with intense heavy ion beams. The electrons suffer practically the same displacement under the influence of the magnetic field, regardless of their offset. At an offset of 10 mm the deviation from the shift at the ion beam axis is less than 3 %. For the experimental investigations of the EBI diagnostic method an offline experiment had been set up at the HHT experimental area at GSI in Darmstadt. The Coulomb field of the ion beam had been simulated by electrostatically charged wires. In case of a single wire, the experimental results are in good agreement with the theoretical model for deflection angles up to 20 mrad. This confirms the results of the numerical studies. To simulate the field within an ion beam, several wires have been clamped parallel to each other within a plane perpendicular to the electron beam. The electrons thus could pass through the spaces between the wires. The results of this experiments have quantitatively confirmed the prediction of the theoretical model that the derivative of the deflection angle with respect to the offset is proportional to the charge distribution in the cross section of the ion beam. Quantitatively, however, deviations from the theoretical model

  12. The electron-impact ionization of Ar and Kr revisited: A critical analysis of double-to-single ionization cross section ratio measurements using the fast-atom-beam technique

    International Nuclear Information System (INIS)

    Tarnovsky, V.; Becker, K.

    1992-01-01

    We report new measurements of the absolute electron-impact double ionization cross sections for Ar and Kr and of the ratios of double-to-single ionization for impact energies from threshold to 200 eV using the crossed electron-beam - fast-atom-beam technique. The work was motivated by the recently highlighted spread of about 30% in the Ar 2+ /Ar + ionization cross section ratios obtained by several groups using different experimental techniques. Such a spread is inconsistent with statistical uncertainties of typically 3% or less that were quoted for the various reported ratios. A similar situation exists for Kr where the spread among the recently published Kr 2+ /Kr + ionization cross section ratios is about 15%. We made an attempt to identify all potential systematic errors inherent to the fast-beam technique that could affect the measurement of cross section ratios with special emphasis on those systematic errors that could influence the detection of singly and doubly charged product ions differently. We found Ar 2+ /Ar + and Kr 2+ /Kr + cross section ratios of, respectively 0.066±0.007 and 0.087±0.008 at 100 eV which confirm earlier measurements using the same experimental technique. The error limits on cross sections ratios of multiple-to-single ionization for the same target atom and at least ±10% for ratios of single ionization cross sections for different target species. Our error limits are dominated by systematic uncertainties of the apparatus which do not cancel when cross section ratios are measured, since the ratios are obtained under similar, but not identical experimental conditions. (orig.)

  13. Diuretic response to acute hypertension is blunted during angiotensin II clamp

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Zhang, Yibin; Yang, Li E

    2002-01-01

    and endogenous lithium clearance increased two- and threefold, respectively. We conclude that HOE-140, an inhibitor of the B(2) receptor, potentiates the sensitivity of arterial pressure to ANG II and that clamping systemic ANG II levels during acute hypertension blunts the magnitude of the pressure diuretic...... whether the suppression of the renin-angiotensin system during acute hypertension affects the magnitude of the inhibition of PT fluid and sodium reabsorption, plasma ANG II levels were clamped by infusion of the angiotensin-converting enzyme (ACE) inhibitor captopril (12 microg/min) and ANG II after...... ("ANG II clamp"). When blood pressure was acutely increased 50-60 mmHg by arterial constriction without ANG II clamp, urine output and endogenous lithium clearance increased 4.0- and 6.7-fold, respectively. With ANG II clamp, the effects of acute hypertension were reduced 50%: urine output...

  14. A reduction clamp for an aiming component in associated acetabular fractures

    Directory of Open Access Journals (Sweden)

    Zhang-Fu Wang

    2015-01-01

    Full Text Available Background: The treatment of acetabular fractures is complex and requires specialized equipment. However, all currently available instruments have some disadvantages. A new reduction clamp that can firmly enable reduction and not hinder subsequent fixation procedures for some special fracture types is needed. Materials and Methods: In this study, we introduce a new acetabular clamp and its preliminary clinical application in three T-shaped acetabular fractures. Results: This new clamp can successfully pull the posterior column back to the anterior column and firmly maintain the reduction. This clamp′s aiming plate can facilitate the insertion of long lag screws. The clamp is also easy to assemble and use. Conclusion: This reduction clamp is a useful instrument that can facilitate open reduction and internal fixation of acetabular fractures.

  15. Beam cooling

    OpenAIRE

    Danared, H

    2006-01-01

    Beam cooling is the technique of reducing the momentum spread and increasing the phase-space density of stored particle beams. This paper gives an introduction to beam cooling and Liouville’s theorem, and then it describes the three methods of active beam cooling that have been proven to work so far, namely electron cooling, stochastic cooling, and laser cooling. Ionization cooling is also mentioned briefly.

  16. Molecular beams

    International Nuclear Information System (INIS)

    Pendelbury, J.M.; Smith, K.F.

    1987-01-01

    Studies with directed collision-free beams of particles continue to play an important role in the development of modern physics and chemistry. The deflections suffered by such beams as they pass through electric and magnetic fields or laser radiation provide some of the most direct information about the individual constituents of the beam; the scattering observed when two beams intersect yields important data about the intermolecular forces responsible for the scattering. (author)

  17. CO2 Clamping, Peripheral and Central Fatigue during Hypoxic Knee Extensions in Men.

    Science.gov (United States)

    Rupp, Thomas; Mallouf, Thibault Le Roux; Perrey, Stéphane; Wuyam, Bernard; Millet, Guillaume Y; Verges, Samuel

    2015-12-01

    The central nervous system can play a critical role in limiting exercise performance during hypoxic conditions. Hypocapnia, which is associated with hypoxia-induced hyperventilation, may affect cerebral perfusion. We hypothesized that CO2 clamping during hypoxic isometric knee extensions would improve cerebral oxygenation and reduce central fatigue. Fifteen healthy men (mean ± SD: age, 25 ± 8 yr; body mass, 72 ± 11 kg; height, 179 ± 7 cm) performed intermittent isometric knee extensions at ∼50% of maximal voluntary contraction to task failure in normoxia, hypoxia with CO2 clamping (arterial O2 saturation, 80% ± 2%; end-tidal CO2 partial pressure, 40 ± 2 mm Hg), and hypoxia without CO2 clamping (arterial O2 saturation, 80% ± 3%). Transcranial magnetic stimulation and femoral nerve electrical stimulation were used to assess central and peripheral determinants of fatigue. Prefrontal cortex and quadriceps femoris oxygenation were monitored by multichannel near-infrared spectroscopy. Exercise duration was reduced to a similar extent in hypoxia with CO2 clamping (997 ± 460 s) or hypoxia without CO2 clamping (929 ± 412 s) compared to normoxia (1473 ± 876 s; P stimulation maximal voluntary activation decreased to a greater extent at task failure in hypoxia without CO2 clamping (-18% ± 8%) compared to hypoxia with CO2 clamping (-9% ± 9%; P < 0.01) and normoxia (-10% ± 7%; P < 0.05). Conversely, exercise-induced peripheral fatigue was larger in hypoxia with CO2 clamping than in hypoxia without CO2 clamping (e.g., Db10-to-Db100 ratio of 0.54 ± 0.12 and 0.63 ± 0.11 at task failure, respectively; P < 0.05). The results demonstrate that CO2 clamping can alter central and peripheral mechanisms that contribute to neuromuscular fatigue during hypoxic isometric knee extensions in men. Hypocapnia impairs cerebral oxygenation and central drive but exerts a protective effect against fatigability in muscles.

  18. Escherichia coli processivity clamp β from DNA polymerase III is dynamic in solution†

    Science.gov (United States)

    Fang, Jing; Engen, John R.; Beuning, Penny J.

    2011-01-01

    Escherichia coli DNA polymerase III is a highly processive replicase due to the presence of the β clamp protein that tethers DNA polymerases to DNA. The β clamp is a head-to-tail ring-shaped homodimer, in which each protomer contains three structurally similar domains. Although multiple studies have probed the functions of the β clamp, a detailed understanding of the conformational dynamics of the β clamp in solution is lacking. Here we used hydrogen exchange mass spectrometry to characterize the conformation and dynamics of the intact dimer β clamp and a variant form (I272A/L273A) with diminished ability to dimerize in solution. Our data indicate that the β clamp is not a static closed ring but rather is dynamic in solution. The three domains showed different dynamics though they share a highly similar tertiary structure. Domain I, which controls the opening of the clamp by dissociating from Domain III, contained several highly flexible peptides that underwent partial cooperative unfolding (EX1 kinetics) with a half-life ~4 h. The comparison between the β monomer variant and the wild-type β clamp showed that the β monomer was more dynamic. In the monomer, partial unfolding was much faster and additional regions of Domain III also underwent partial unfolding with a half-life ~1 h. Our results suggest that the δ subunit of the clamp loader may function as a “ring holder” to stabilize the transient opening of the β clamp, rather than as a “ring opener”. PMID:21657794

  19. Vibration and instability of a viscous-fluid-conveying single-walled carbon nanotube embedded in a visco-elastic medium

    International Nuclear Information System (INIS)

    Soltani, P; Farshidianfar, A; Taherian, M M

    2010-01-01

    In this study, for the first time, the transverse vibrational model of a viscous-fluid-conveying single-walled carbon nanotube (SWCNT) embedded in biological soft tissue is developed. Nonlocal Euler-Bernoulli beam theory has been used to investigate fluid-induced vibration of the SWCNT while visco-elastic behaviour of the surrounding tissue is simulated by the Kelvin-Voigt model. The results indicate that the resonant frequencies and the critical flow velocity at which structural instability of nanotubes emerges are significantly dependent on the properties of the medium around the nanotube, the boundary conditions, the viscosity of the fluid and the nonlocal parameter. Detailed results are demonstrated for the dependence of damping and elastic properties of the medium on the resonant frequencies and the critical flow velocity. Three standard boundary conditions, namely clamped-clamped, clamped-pinned and pinned-pinned, are applied to study the effect of the supported end conditions. Furthermore, it is found that the visco-elastic foundation causes an obvious reduction in the critical velocity in comparison with the elastic foundation, in particular for a compliant medium, pinned-pinned boundary condition, high viscosity of the fluid and small values of the nonlocal coefficient.

  20. Effects of Delayed Umbilical Cord Clamping vs Early Clamping on Anemia in Infants at 8 and 12 Months: A Randomized Clinical Trial.

    Science.gov (United States)

    Kc, Ashish; Rana, Nisha; Målqvist, Mats; Jarawka Ranneberg, Linda; Subedi, Kalpana; Andersson, Ola

    2017-03-01

    Delayed umbilical cord clamping has been shown to improve iron stores in infants to 6 months of age. However, delayed cord clamping has not been shown to prevent iron deficiency or anemia after 6 months of age. To investigate the effects of delayed umbilical cord clamping, compared with early clamping, on hemoglobin and ferritin levels at 8 and 12 months of age in infants at high risk for iron deficiency anemia. This randomized clinical trial included 540 late preterm and term infants born vaginally at a tertiary hospital in Kathmandu, Nepal, from October 2 to November 21, 2014. Follow-up included blood levels of hemoglobin and ferritin at 8 and 12 months of age. Follow-up was completed on December 11, 2015. Analysis was based on intention to treat. Infants were randomized to delayed umbilical cord clamping (≥180 seconds after delivery) or early clamping (≤60 seconds after delivery). Main outcomes included hemoglobin and anemia levels at 8 months of age with the power estimate based on the prevalence of anemia. Secondary outcomes included hemoglobin and anemia levels at 12 months of age and ferritin level, iron deficiency, and iron deficiency anemia at 8 and 12 months of age. In this study of 540 infants (281 boys [52.0%] and 259 girls [48.0%]; mean [SD] gestational age, 39.2 [1.1] weeks), 270 each were randomized to the delayed and early clamping groups. At 8 months of age, 212 infants (78.5%) from the delayed group and 188 (69.6%) from the early clamping group returned for blood sampling. After multiple imputation analysis, infants undergoing delayed clamping had higher levels of hemoglobin (10.4 vs 10.2 g/dL; difference, 0.2 g/dL; 95% CI, 0.1 to 0.4 g/dL). Delayed cord clamping also reduced the prevalence of anemia (hemoglobin level infants (relative risk, 0.89; 95% CI, 0.81-0.98; number needed to treat [NNT], 11; 95% CI, 6-54). At 8 months, the risk for iron deficiency was reduced in the delayed clamping group in 60 (22.2%) vs 103 (38.1%) patients