WorldWideScience

Sample records for singles rate method

  1. Single- versus multiple-sample method to measure glomerular filtration rate.

    Science.gov (United States)

    Delanaye, Pierre; Flamant, Martin; Dubourg, Laurence; Vidal-Petiot, Emmanuelle; Lemoine, Sandrine; Cavalier, Etienne; Schaeffner, Elke; Ebert, Natalie; Pottel, Hans

    2018-01-08

    There are many different ways to measure glomerular filtration rate (GFR) using various exogenous filtration markers, each having their own strengths and limitations. However, not only the marker, but also the methodology may vary in many ways, including the use of urinary or plasma clearance, and, in the case of plasma clearance, the number of time points used to calculate the area under the concentration-time curve, ranging from only one (Jacobsson method) to eight (or more) blood samples. We collected the results obtained from 5106 plasma clearances (iohexol or 51Cr-ethylenediaminetetraacetic acid (EDTA)) using three to four time points, allowing GFR calculation using the slope-intercept method and the Bröchner-Mortensen correction. For each time point, the Jacobsson formula was applied to obtain the single-sample GFR. We used Bland-Altman plots to determine the accuracy of the Jacobsson method at each time point. The single-sample method showed within 10% concordances with the multiple-sample method of 66.4%, 83.6%, 91.4% and 96.0% at the time points 120, 180, 240 and ≥300 min, respectively. Concordance was poorer at lower GFR levels, and this trend is in parallel with increasing age. Results were similar in males and females. Some discordance was found in the obese subjects. Single-sample GFR is highly concordant with a multiple-sample strategy, except in the low GFR range (<30 mL/min). © The Author 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  2. Measurement of glomerular filtration rate in adults: accuracy of five single-sample plasma clearance methods

    DEFF Research Database (Denmark)

    Rehling, M; Rabøl, A

    1989-01-01

    After an intravenous injection of a tracer that is removed from the body solely by filtration in the kidneys, the glomerular filtration rate (GFR) can be determined from its plasma clearance. The method requires a great number of blood samples but collection of urine is not needed. In the present...

  3. Standard practice for measurement of the glass dissolution rate using the single-pass flow-through test method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes a single-pass flow-through (SPFT) test method that can be used to measure the dissolution rate of a homogeneous silicate glass, including nuclear waste glasses, in various test solutions at temperatures less than 100°C. Tests may be conducted under conditions in which the effects from dissolved species on the dissolution rate are minimized to measure the forward dissolution rate at specific values of temperature and pH, or to measure the dependence of the dissolution rate on the concentrations of various solute species. 1.2 Tests are conducted by pumping solutions in either a continuous or pulsed flow mode through a reaction cell that contains the test specimen. Tests must be conducted at several solution flow rates to evaluate the effect of the flow rate on the glass dissolution rate. 1.3 This practice excludes static test methods in which flow is simulated by manually removing solution from the reaction cell and replacing it with fresh solution. 1.4 Tests may be conducted wit...

  4. Analysis of the influence of the demand rate on the accident rate of a plant equipped with a single protective channel by Generalized Perturbation Theory (GPT) methods

    International Nuclear Information System (INIS)

    Franca Walter, F.L.; Alvim, A.C.M.; Silva, F.C. da; Melo e Frutuoso, P.F.

    1995-01-01

    The application of the GPT methodology to a reliability engineering problem of great practical interest is discussed: that of the analysis of the influence of the demand rate on the accident rate of a process plant equipped with a single protective channel. This problem has been solved in the literature by traditional methods, that is, for each demand rate value the system of differential equations that governs the system behavior (derived from a Markovian reliability model) is solved and the resulting points are employed to generate the desired curve. This sensitivity analysis has been performed by means of a GPT approach in order to show how it could simplify the calculations. Although an analytical solution is available for the above equations, the application of the GPT approach needed the solution of the system for a few points (reference solutions) and the results agree very well with those published. (author). 9 refs, 4 figs

  5. Comparison of single point normalized and modified Gate's method for measurement of glomerular filtration rate by nuclear medicine

    International Nuclear Information System (INIS)

    Fonseca, L.M.B. da; Fonseca, N.M.; Martins, E.; Pereira, E.

    1992-01-01

    Glomerular filtration rate was measured in 22 patients (mean age 30 years) using a noninvasive modified Gates method and the results were compared to the one point normalized technique. The values obtained were 74-11.7 and 82-11.09 ml/min., respectively. The advantages of the method are its reliability, easy adaptation to small laboratories and the avoidance of blood and urine sampling. (author)

  6. Study on the Optimal Number of Transducers for Pipe Flow Rate Measurement Downstream of a Single Elbow Using the Ultrasonic Velocity Profile Method

    Directory of Open Access Journals (Sweden)

    Sanehiro Wada

    2012-01-01

    Full Text Available This paper presents a new estimation method to determine the optimal number of transducers using an Ultrasonic Velocity Profile (UVP for accurate flow rate measurement downstream of a single elbow. Since UVP can measure velocity profiles over a pipe diameter and calculate the flow rate by integrating these velocity profiles, it is also expected to obtain an accurate flow rate using multiple transducers under nondeveloped flow conditions formed downstream of an elbow. The new estimation method employs a wave number of velocity profile fluctuations along a circle on a pipe cross-section using Fast Fourier Transform (FFT. The optimal number of transducers is estimated based on the sampling theorem. To evaluate this method, a preliminary experiment and numerical simulations using Computational Fluid Dynamics (CFD are conducted. The evaluating regions of velocity profiles are located at 3 times of a pipe diameter ( for the experiment, and 1 and for the simulations downstream of an elbow, respectively. Reynolds numbers for the experiment and simulations are set at and , respectively. These results indicate the efficiency of this new method.

  7. Retrospective study of renal distribution volume with DTPA-99mTc: performance of single plasma method for glomerular filtration rate estimation

    International Nuclear Information System (INIS)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P.

    1997-01-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m 2 ). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m 2 (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR 234 = f (V 4h ) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen's equation. (authors)

  8. Hole hopping rates in single strand oligonucleotides

    Energy Technology Data Exchange (ETDEWEB)

    Borrelli, Raffaele [Dipartimento di Scienze Agrarie, Forestali e Alimentari, Università di Torino, Largo Paolo Braccini 2, I-10095 Grugliasco, TO (Italy); Capobianco, Amedeo [Dipartimento di Chimica e Biologia, Università di Salerno, Via Giovanni Paolo II, I-84084 Fisciano, SA (Italy); Peluso, Andrea, E-mail: apeluso@unisa.it [Dipartimento di Chimica e Biologia, Università di Salerno, Via Giovanni Paolo II, I-84084 Fisciano, SA (Italy)

    2014-08-31

    Highlights: • DNA hole transfer rates have been computed. • Delocalized adenine domains significantly affect hole transfer rates in DNA. • Franck–Condon weighted density of state from DFT normal modes. • DNA application in molecular electronics. - Abstract: The rates of hole transfer between guanine and adenine in single strand DNA have been evaluated by using Fermi’s golden rule and Kubo’s generating function approach for the Franck–Condon weighted density of states. The whole sets of the normal modes and vibrational frequencies of the two nucleobases, obtained at DFT/B3LYP level of calculation, have been considered in computations. The results show that in single strand the pyramidalization/planarization mode of the amino groups of both nucleobases plays the major role. At room temperature, the Franck–Condon density of states extends over a wide range of hole site energy difference, 0–1 eV, giving some hints about the design of oligonucleotides of potential technological interest.

  9. GROWTH RATE DISTRIBUTION OF BORAX SINGLE CRYSTALS ON THE (001 FACE UNDER VARIOUS FLOW RATES

    Directory of Open Access Journals (Sweden)

    Suharso Suharso

    2010-06-01

    Full Text Available The growth rates of borax single crystals from aqueous solutions at various flow rates in the (001 direction were measured using in situ cell method. From the growth rate data obtained, the growth rate distribution of borax crystals was investigated using Minitab Software and SPSS Software at relative supersaturation of 0807 and temperature of 25 °C. The result shows that normal, gamma, and log-normal distribution give a reasonably good fit to GRD. However, there is no correlation between growth rate distribution and flow rate of solution.   Keywords: growth rate dispersion (GRD, borax, flow rate

  10. Evaluation of the Success Rate of Nonsurgical Single Visit Retreatment

    Science.gov (United States)

    Ashraf, Hengameh; Milani, Amin Salem; Shakeri Asadi, Shahla

    2007-01-01

    INTRODUCTION: Advantages of endodontic treatments over tooth extraction have increased the demands for these treatments. Success rate of these treatments is generally lower than the primary root canal therapies. Recently, single visit treatments have gained more popularity. But, the influence of completing retreatment in a single appointment on success of the treatment is still a controversy. The aim of this study was evaluating the most common causes of failures and determining the success rate of completing retreatments in single appointment. MATERIALS AND METHODS: Hundred and twenty four patients who had single appointment retreatment within past 4 years in postgraduate ward of Shahid Beheshti Dental School were selected and clinical and radiographic examinations were carried out. The data were analyzed by SPSS using Chi-square and Exact Fisher tests. RESULTS: Success rate and uncertain cases were shown to be 50.7% and 34.2%, respectively and failure rate was 15.1%. Presence of periradicular lesion or history of swelling prior to retreatment had significant effect on the success of single visit retreatments (pretreatments was significantly higher in cases referred for restorative purposes compared with retreatments for nonrestorative purposes (pretreatments is up to 84.9% which is considerably higher in cases referred for restorative purposes. So based on the results of this study single appointment retreatment of symptom less teeth is recommended. PMID:24327818

  11. Comparing methods for single paragraph similarity analysis.

    Science.gov (United States)

    Stone, Benjamin; Dennis, Simon; Kwantes, Peter J

    2011-01-01

    The focus of this paper is two-fold. First, similarities generated from six semantic models were compared to human ratings of paragraph similarity on two datasets-23 World Entertainment News Network paragraphs and 50 ABC newswire paragraphs. Contrary to findings on smaller textual units such as word associations (Griffiths, Tenenbaum, & Steyvers, 2007), our results suggest that when single paragraphs are compared, simple nonreductive models (word overlap and vector space) can provide better similarity estimates than more complex models (LSA, Topic Model, SpNMF, and CSM). Second, various methods of corpus creation were explored to facilitate the semantic models' similarity estimates. Removing numeric and single characters, and also truncating document length improved performance. Automated construction of smaller Wikipedia-based corpora proved to be very effective, even improving upon the performance of corpora that had been chosen for the domain. Model performance was further improved by augmenting corpora with dataset paragraphs. Copyright © 2010 Cognitive Science Society, Inc.

  12. Development of novel growth methods for halide single crystals

    Science.gov (United States)

    Yokota, Yuui; Kurosawa, Shunsuke; Shoji, Yasuhiro; Ohashi, Yuji; Kamada, Kei; Yoshikawa, Akira

    2017-03-01

    We developed novel growth methods for halide scintillator single crystals with hygroscopic nature, Halide micro-pulling-down [H-μ-PD] method and Halide Vertical Bridgman [H-VB] method. The H-μ-PD method with a removable chamber system can grow a single crystal of halide scintillator material with hygroscopicity at faster growth rate than the conventional methods. On the other hand, the H-VB method can grow a large bulk single crystal of halide scintillator without a quartz ampule. CeCl3, LaBr3, Ce:LaBr3 and Eu:SrI2 fiber single crystals could be grown by the H-μ-PD method and Eu:SrI2 bulk single crystals of 1 and 1.5 inch in diameter could be grown by the H-VB method. The grown fiber and bulk single crystals showed comparable scintillation properties to the previous reports using the conventional methods.

  13. The constant rate injection tracer method - principle and application of a useful system for the investigation of single- and two-phase flows in thermal power plants

    International Nuclear Information System (INIS)

    Ederhof, A.; Lindberg, G.

    1985-01-01

    The ''tracer technique'', developed by Brown, Boveri and Company, permits measurement of water (liquid) mass flows, as part of the requested steam wetness, in steam turbine cycles. The additionally required steam mass flows can be calculated from mass flow balances (e.g. after condensation in a heater and subsequent measuring of the condensate flow) or energy balances. This measuring method is basically a dilution measurement using a radioactive or inactive tracer. If the radionuclide 24 Na is used, the measuring uncertainties will be typically 0.5-1.0%. The tracer technique was developed for largely automated parallel measurements on up to 30 lines of large capacity steam turbines. The example of the Ringhals 3 nuclear power plant illustrates that the tracer measuring method, applied during an acceptance test, yields better information on the functioning of the turbine cycle. (orig./GL) [de

  14. Time relative single-photon (photoelectron) method

    International Nuclear Information System (INIS)

    Luo Binqiao

    1988-01-01

    A single-photon (photoelectron) measuring system is designed. It researches various problems in single-photon (photoelectron) method. The electronic resolving time is less than 25 ps. The resolving time of single-photon (photoelectron) measuring system is 25 to 65 ps

  15. Low-temperature phonoemissive tunneling rates in single molecule magnets

    Science.gov (United States)

    Liu, Yun; Garg, Anupam

    2016-03-01

    Tunneling between the two lowest energy levels of single molecule magnets with Ising type anisotropy, accompanied by the emission or absorption of phonons, is considered. Quantitatively accurate calculations of the rates for such tunneling are performed for a model Hamiltonian especially relevant to the best studied example, Fe8. Two different methods are used: high-order perturbation theory in the spin-phonon interaction and the non-Ising-symmetric parts of the spin Hamiltonian, and a novel semiclassical approach based on spin-coherent-state-path-integral instantons. The methods are found to be in good quantitative agreement with other, and consistent with previous approaches to the problem. The implications of these results for magnetization of molecular solids of these molecules are discussed briefly.

  16. Single Event Rates for Devices Sensitive to Particle Energy

    Science.gov (United States)

    Edmonds, L. D.; Scheick, L. Z.; Banker, M. W.

    2012-01-01

    Single event rates (SER) can include contributions from low-energy particles such that the linear energy transfer (LET) is not constant. Previous work found that the environmental description that is most relevant to the low-energy contribution to the rate is a "stopping rate per unit volume" even when the physical mechanisms for a single-event effect do not require an ion to stop in some device region. Stopping rate tables are presented for four heavy-ion environments that are commonly used to assess device suitability for space applications. A conservative rate estimate utilizing limited test data is derived, and the example of SEGR rate in a power MOSFET is presented.

  17. Single crystal plasticity by modeling dislocation density rate behavior

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Benjamin L [Los Alamos National Laboratory; Bronkhorst, Curt [Los Alamos National Laboratory; Beyerlein, Irene [Los Alamos National Laboratory; Cerreta, E. K. [Los Alamos National Laboratory; Dennis-Koller, Darcie [Los Alamos National Laboratory

    2010-12-23

    The goal of this work is to formulate a constitutive model for the deformation of metals over a wide range of strain rates. Damage and failure of materials frequently occurs at a variety of deformation rates within the same sample. The present state of the art in single crystal constitutive models relies on thermally-activated models which are believed to become less reliable for problems exceeding strain rates of 10{sup 4} s{sup -1}. This talk presents work in which we extend the applicability of the single crystal model to the strain rate region where dislocation drag is believed to dominate. The elastic model includes effects from volumetric change and pressure sensitive moduli. The plastic model transitions from the low-rate thermally-activated regime to the high-rate drag dominated regime. The direct use of dislocation density as a state parameter gives a measurable physical mechanism to strain hardening. Dislocation densities are separated according to type and given a systematic set of interactions rates adaptable by type. The form of the constitutive model is motivated by previously published dislocation dynamics work which articulated important behaviors unique to high-rate response in fcc systems. The proposed material model incorporates thermal coupling. The hardening model tracks the varying dislocation population with respect to each slip plane and computes the slip resistance based on those values. Comparisons can be made between the responses of single crystals and polycrystals at a variety of strain rates. The material model is fit to copper.

  18. Method for manufacturing a single crystal nanowire

    NARCIS (Netherlands)

    van den Berg, Albert; Bomer, Johan G.; Carlen, Edwin; Chen, S.; Kraaijenhagen, Roderik Adriaan; Pinedo, Herbert Michael

    2013-01-01

    A method for manufacturing a single crystal nano-structure is provided comprising the steps of providing a device layer with a 100 structure on a substrate; providing a stress layer onto the device layer; patterning the stress layer along the 110 direction of the device layer; selectively removing

  19. Method for manufacturing a single crystal nanowire

    NARCIS (Netherlands)

    van den Berg, Albert; Bomer, Johan G.; Carlen, Edwin; Chen, S.; Kraaijenhagen, R.A.; Pinedo, Herbert Michael

    2010-01-01

    A method for manufacturing a single crystal nano-structure is provided comprising the steps of providing a device layer with a 100 structure on a substrate; providing a stress layer onto the device layer; patterning the stress layer along the 110 direction of the device layer; selectively removing

  20. Method of controlling fusion reaction rates

    Science.gov (United States)

    Kulsrud, Russell M.; Furth, Harold P.; Valeo, Ernest J.; Goldhaber, Maurice

    1988-01-01

    A method of controlling the reaction rates of the fuel atoms in a fusion reactor comprises the step of polarizing the nuclei of the fuel atoms in a particular direction relative to the plasma confining magnetic field. Fusion reaction rates can be increased or decreased, and the direction of emission of the reaction products can be controlled, depending on the choice of polarization direction.

  1. Easily controlled dye doped phosphorescent OLEDs with evaporation rate in single furnace

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoudi, Malek; Janghouri, Mohammad; Mohajerani, Ezeddin, E-mail: e-mohajerani@sbu.ac.ir

    2015-04-15

    Electrical and optical characteristic, surface morphology and energy transfer of Ir(ppy){sub 3}:PtTPP were studied as a function of thermal evaporation rate. We have investigated the effect of various evaporation rates for mixture of dyes using single furnace method. When the deposition rate increased from 0.5 to 5 Ǻ/s, the luminescence efficiency, current density and energy transfer of OLED increased. AFM measurements showed that the surface roughness of the Ir(ppy){sub 3}:PtTPP films decreased with increasing deposition rates. These blends show excellent red emitting guest–host system with easier deposition rate control. - Highlights: • Thermal evaporation rate is used to control the doping by using single furnace. • The advantages of using single furnace are discussed. • It is shown that the evaporation rate also affects the surface roughness.

  2. Polymerase specific error rates and profiles identified by single molecule sequencing.

    Science.gov (United States)

    Hestand, Matthew S; Van Houdt, Jeroen; Cristofoli, Francesca; Vermeesch, Joris R

    2016-01-01

    DNA polymerases have an innate error rate which is polymerase and DNA context specific. Historically the mutational rate and profiles have been measured using a variety of methods, each with their own technical limitations. Here we used the unique properties of single molecule sequencing to evaluate the mutational rate and profiles of six DNA polymerases at the sequence level. In addition to accurately determining mutations in double strands, single molecule sequencing also captures direction specific transversions and transitions through the analysis of heteroduplexes. Not only did the error rates vary, but also the direction specific transitions differed among polymerases. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A method of object recognition for single pixel imaging

    Science.gov (United States)

    Li, Boxuan; Zhang, Wenwen

    2018-01-01

    Computational ghost imaging(CGI), utilizing a single-pixel detector, has been extensively used in many fields. However, in order to achieve a high-quality reconstructed image, a large number of iterations are needed, which limits the flexibility of using CGI in practical situations, especially in the field of object recognition. In this paper, we purpose a method utilizing the feature matching to identify the number objects. In the given system, approximately 90% of accuracy of recognition rates can be achieved, which provides a new idea for the application of single pixel imaging in the field of object recognition

  4. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  5. A simple method for the estimation of glomerular filtration rate

    International Nuclear Information System (INIS)

    Groth, T.; Tengstroem, B.

    1977-01-01

    A simple method is presented for indirect estimation of the glomerular filtration rate from two venous blood samples, drawn after a single injection of a small dose of [ 125 I]sodium iothalamate (10 μCi). The method does not require exact dosage, as the first sample, taken after a few minutes (t=5 min) after injection, is used to normilize the value of the second sample, which should be taken in between 2-4 h after injection. The glomerular filtration rate, as measured by standard inulin clearance, may then be predicted from the logarithm of the normalized value and linear regression formulas with a standard error of estimate of the order of 1-2 ml/min/1.73 m 2 . The slope-intercept method for direct estimation of glomerular filtration rate is also evaluated and found to significantly underestimate standard insulin clearance. The normalized 'single-point' method is concluded to be superior to the slope-intercept method and more sophisticated methods using curve fitting technique, with regard to predictive force and clinical applicability. (Auth.)

  6. Retrospective study of renal distribution volume with DTPA-{sup 99m}Tc: performance of single plasma method for glomerular filtration rate estimation; Etude retrospective du volume de distribution du traceur renal DTPA-{sup 99m}Tc: performance d`une methode a un prelevement sanguin pour l`estimation du debit de filtration glomerulaire

    Energy Technology Data Exchange (ETDEWEB)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P. [Centre Hospitalier Regional Augustin-Morvan, 29 - Brest (France)

    1997-08-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours) three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m{sup 2}). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m{sup 2} (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V)). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR{sub 234} = f (V{sub 4h}) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen`s equation. (authors). 17 refs.

  7. Fastest Rates for Stochastic Mirror Descent Methods

    KAUST Repository

    Hanzely, Filip

    2018-03-20

    Relative smoothness - a notion introduced by Birnbaum et al. (2011) and rediscovered by Bauschke et al. (2016) and Lu et al. (2016) - generalizes the standard notion of smoothness typically used in the analysis of gradient type methods. In this work we are taking ideas from well studied field of stochastic convex optimization and using them in order to obtain faster algorithms for minimizing relatively smooth functions. We propose and analyze two new algorithms: Relative Randomized Coordinate Descent (relRCD) and Relative Stochastic Gradient Descent (relSGD), both generalizing famous algorithms in the standard smooth setting. The methods we propose can be in fact seen as a particular instances of stochastic mirror descent algorithms. One of them, relRCD corresponds to the first stochastic variant of mirror descent algorithm with linear convergence rate.

  8. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  9. Community-Level Characteristics Associated With Variation in Rates of Homelessness Among Families and Single Adults

    Science.gov (United States)

    Fargo, Jamison D.; Munley, Ellen A.; Byrne, Thomas H.; Montgomery, Ann Elizabeth; Culhane, Dennis P.

    2013-01-01

    Objectives. We modeled rates of family and single-adult homelessness in the United States in metropolitan and nonmetropolitan regions and as a function of community-level demographic, behavioral, health, economic, and safety net characteristics. Methods. We entered community-level characteristics and US Department of Housing and Urban Development point-in-time counts for a single night in January 2009 into separate mixed-effects statistical analyses that modeled homelessness rates for 4 subpopulations: families and single adults in metropolitan and nonmetropolitan regions. Results. Community-level factors accounted for 25% to 50% of the variance in homelessness rates across models. In metropolitan regions, alcohol consumption, social support, and several economic indicators were uniquely associated with family homelessness, and drug use and homicide were uniquely associated with single-adult homelessness. In nonmetropolitan regions, life expectancy, religious adherence, unemployment, and rent burden were uniquely associated with family homelessness, and health care access, crime, several economic indicators, and receipt of Supplemental Security Income were uniquely associated with single-adult homelessness. Conclusions. Considering homeless families and single adults separately enabled more precise modeling of associations between homelessness rates and community-level characteristics, indicating targets for interventions to reduce homelessness among these subpopulations. PMID:24148057

  10. Handbook of statistical methods single subject design

    CERN Document Server

    Satake, Eiki; Maxwell, David L

    2008-01-01

    This book is a practical guide of the most commonly used approaches in analyzing and interpreting single-subject data. It arranges the methodologies used in a logical sequence using an array of research studies from the existing published literature to illustrate specific applications. The book provides a brief discussion of each approach such as visual, inferential, and probabilistic model, the applications for which it is intended, and a step-by-step illustration of the test as used in an actual research study.

  11. GNSS Single Frequency, Single Epoch Reliable Attitude Determination Method with Baseline Vector Constraint

    Directory of Open Access Journals (Sweden)

    Ang Gong

    2015-12-01

    Full Text Available For Global Navigation Satellite System (GNSS single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.

  12. GNSS Single Frequency, Single Epoch Reliable Attitude Determination Method with Baseline Vector Constraint.

    Science.gov (United States)

    Gong, Ang; Zhao, Xiubin; Pang, Chunlei; Duan, Rong; Wang, Yong

    2015-12-02

    For Global Navigation Satellite System (GNSS) single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA) method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.

  13. A brief introduction to single-molecule fluorescence methods

    NARCIS (Netherlands)

    Wildenberg, S.M.J.L.; Prevo, B.; Peterman, E.J.G.; Peterman, EJG; Wuite, GJL

    2011-01-01

    One of the more popular single-molecule approaches in biological science is single-molecule fluorescence microscopy, which is the subject of the following section of this volume. Fluorescence methods provide the sensitivity required to study biology on the single-molecule level, but they also allow

  14. A brief introduction to single-molecule fluorescence methods

    NARCIS (Netherlands)

    van den Wildenberg, Siet M.J.L.; Prevo, Bram; Peterman, Erwin J.G.

    2018-01-01

    One of the more popular single-molecule approaches in biological science is single-molecule fluorescence microscopy, which will be the subject of the following section of this volume. Fluorescence methods provide the sensitivity required to study biology on the single-molecule level, but they also

  15. Can a single pain rating replace a multiple pain rating in third molar surgery studies? Analysis of 220 patients

    NARCIS (Netherlands)

    Martin, W.J.J.M.; Heymans, M.W.; Skorpil, N.E.; Forouzanfar, T.

    2012-01-01

    This study describes the comparison of multiple and single pain ratings in patients after surgical removal of the third molar. Correlation and agreement analysis were performed between the average pain intensity measured three times a day over a period of 7 days and one single pain rating

  16. Methods for Gas Sensing with Single-Walled Carbon Nanotubes

    Science.gov (United States)

    Kaul, Anupama B. (Inventor)

    2013-01-01

    Methods for gas sensing with single-walled carbon nanotubes are described. The methods comprise biasing at least one carbon nanotube and exposing to a gas environment to detect variation in temperature as an electrical response.

  17. Normalized Convergence Rates for the PSMG Method

    Science.gov (United States)

    1990-10-01

    differences qualitatively affected the results of [4], the basic approach to comparing the PSMG and standard multigrid methods outlined in [4] is not in...refer to [8] for a detailed comparison of several hundred red-black standard multigrid methods , including several that qxe somewhat more efficient than...the BR3 method. REFERENCES [1] P. FREDERICKSON AND O. MCBRYAN, Parallei super onvergent multigrid, in Multigrid Methods , S. McCormick, ed., Marcel

  18. A single dose of dark chocolate increases parasympathetic modulation and heart rate variability in healthy subjects

    Directory of Open Access Journals (Sweden)

    Ana Amélia Machado DUARTE

    Full Text Available ABSTRACT Objective: The aim of this study was to investigate the acute effect of a single dose of dark chocolate (70% cocoa on blood pressure and heart rate variability. Methods: Thirty-one healthy subjects (aged 18-25 years; both sexes were divided into two groups: 10 subjects in the white chocolate (7.4 g group and 21 in the dark chocolate (10 g group; measurements were performed at the university's physiology lab. An electrocardiogram measured the sympathovagal balance by spectral and symbolic analysis. Results: A single dose of dark chocolate significantly reduced systolic blood pressure and heart rate. After consuming 10 g of dark chocolate, significant increases were observed for heart rate variability, standard deviation of RR intervals standard deviation of all NN intervals, square root of the mean squared differences between adjacent normal RR intervals root mean square of successive differences, and an increase in the high frequency component in absolute values, representing the parasympathetic modulation. Conclusion: In conclusion the importance of our results lies in the magnitude of the response provoked by a single dose of cocoa. Just 10 g of cocoa triggered a significant increase in parasympathetic modulation and heart rate variability. These combined effects can potentially increase life expectancy because a reduction in heart rate variability is associated with several cardiovascular diseases and higher mortality.

  19. A review on measuring methods of gas-liquid flow rates

    International Nuclear Information System (INIS)

    Minemura, Kiyoshi; Yamashita, Masato

    2000-01-01

    This paper presents a review on the state of current measuring techniques for gas-liquid multiphase flow rates. After briefly discussing the basic idea on measuring methods for single-phase and two-phase flows, existing methods for the two-phase flow rates are classified into several types, that is, with or without a homogenizing device, single or combined method of several techniques, with intrusive or non-intrusive sensors, and physical or software method. Each methods are comparatively reviewed in view of measuring accuracy and manageability. Its scope also contains the techniques developed for petroleum-gas-water flow rates. (author)

  20. Time to stabilization in single leg drop jump landings: An examination of calculation methods and assessment of differences in sample rate, filter settings and trial length on outcome values

    NARCIS (Netherlands)

    Fransz, D.P.; Huurnink, A.; Kingma, I.; van Dieen, J.H.

    2015-01-01

    Time to stabilization (TTS) is the time it takes for an individual to return to a baseline or stable state following a jump or hop landing. A large variety exists in methods to calculate the TTS. These methods can be described based on four aspects: (1) the input signal used (vertical,

  1. Comparison of single event upset rates for microelectronic memory devices during interplanetary solar particle events

    Science.gov (United States)

    Mckerracher, P. L.; Kinnison, J. D.; Maurer, R. H.

    1993-01-01

    Variability in the methods and models used for single event upset calculations in microelectronic memory devices can lead to a range of possible upset rates. Using heavy ion and proton data for selected DRAM and SRAM memories, we have calculated an array of upset rates in order to compare the Adams worst case interplanetary solar flare model to a model proposed by scientists at the Jet Propulsion Laboratory. In addition, methods of upset rate calculation are compared: the Cosmic Ray Effects on Microelectronics CREME code and a Monte Carlo algorithm developed at the Applied Physics Laboratory. The results show that use of a more realistic, although still conservative, model of the space environment can have significant cost saving benefits.

  2. Phenotypic fluctuation rendered by a single genotype and evolutionary rate

    Science.gov (United States)

    Yomo, Tetsuya; Ito, Yoichiro; Sato, Katsuhiko; Kaneko, Kunihiko

    2005-05-01

    Do proteins with larger fluctuations in their functions show higher rates of their evolutions? To gain some insight on the question, we conducted an in vitro experimental evolution where a mutant of green fluorescence protein (GFP) with random sequence at its N terminus was subjected to ten cycles of random mutagenesis and selection based on the fluorescence expressed by host Escherichia coli cell. The evolution rate was defined as the fluorescence increase from the parental clone to the selected clone at each generation and the fluctuation was defined as the variance in green fluorescence among the host cells of the parental clone at each generation. The analysis of the relationship between the evolution rate and the fluctuation based on fluctuation-dissipation theorem in statistical physics shows that the gene or encoded protein rendering a larger fluctuation of the fluorescence shows a larger evolution rate, i.e., positive correlation between fluctuation and molecular evolution rate.

  3. Czochralski method of growing single crystals. State-of-art

    International Nuclear Information System (INIS)

    Bukowski, A.; Zabierowski, P.

    1999-01-01

    Modern Czochralski method of single crystal growing has been described. The example of Czochralski process is given. The advantages that caused the rapid progress of the method have been presented. The method limitations that motivated the further research and new solutions are also presented. As the example two different ways of the technique development has been described: silicon single crystals growth in the magnetic field; continuous liquid feed of silicon crystals growth. (author)

  4. High Count Rate Single Photon Counting Detector Array, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — An optical communications receiver requires efficient and high-rate photon-counting capability so that the information from every photon, received at the aperture,...

  5. High Repetition Rate Thermometry System And Method

    KAUST Repository

    Chrystie, Robin

    2015-05-14

    A system and method for rapid thermometry using intrapulse spectroscopy can include a laser for propagating pulses of electromagnetic radiation to a region. Each of the pulses can be chirped. The pulses from the region can be detected. An intrapulse absorbance spectrum can be determined from the pulses. An instantaneous temperature of the region based on the intrapulse absorbance spectrum can be determined.

  6. Single genome retrieval of context-dependent variability in mutation rates for human germline.

    Science.gov (United States)

    Sahakyan, Aleksandr B; Balasubramanian, Shankar

    2017-01-13

    Accurate knowledge of the core components of substitution rates is of vital importance to understand genome evolution and dynamics. By performing a single-genome and direct analysis of 39,894 retrotransposon remnants, we reveal sequence context-dependent germline nucleotide substitution rates for the human genome. The rates are characterised through rate constants in a time-domain, and are made available through a dedicated program (Trek) and a stand-alone database. Due to the nature of the method design and the imposed stringency criteria, we expect our rate constants to be good estimates for the rates of spontaneous mutations. Benefiting from such data, we study the short-range nucleotide (up to 7-mer) organisation and the germline basal substitution propensity (BSP) profile of the human genome; characterise novel, CpG-independent, substitution prone and resistant motifs; confirm a decreased tendency of moieties with low BSP to undergo somatic mutations in a number of cancer types; and, produce a Trek-based estimate of the overall mutation rate in human. The extended set of rate constants we report may enrich our resources and help advance our understanding of genome dynamics and evolution, with possible implications for the role of spontaneous mutations in the emergence of pathological genotypes and neutral evolution of proteomes.

  7. Waste tank ventilation rates measured with a tracer gas method

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Evans, J.C.; Sklarew, D.S.; Mitroshkov, A.V.

    1998-08-01

    Passive ventilation with the atmosphere is used to prevent accumulation of waste gases and vapors in the headspaces of 132 of the 177 high-level radioactive waste Tanks at the Hanford Site in Southeastern Washington State. Measurements of the passive ventilation rates are needed for the resolution of two key safety issues associated with the rates of flammable gas production and accumulation and the rates at which organic salt-nitrate salt mixtures dry out. Direct measurement of passive ventilation rates using mass flow meters is not feasible because ventilation occurs va multiple pathways to the atmosphere (i.e., via the filtered breather riser and unsealed tank risers and pits), as well as via underground connections to other tanks, junction boxes, and inactive ventilation systems. The tracer gas method discussed in this report provides a direct measurement of the rate at which gases are removed by ventilation and an indirect measurement of the ventilation rate. The tracer gas behaves as a surrogate of the waste-generated gases, but it is only diminished via ventilation, whereas the waste gases are continuously released by the waste and may be subject to depletion mechanisms other than ventilation. The fiscal year 1998 tracer studies provide new evidence that significant exchange of air occurs between tanks via the underground cascade pipes. Most of the single-shell waste tanks are connected via 7.6-cm diameter cascade pipes to one or two adjacent tanks. Tracer gas studies of the Tank U-102/U-103 system indicated that the ventilation occurring via the cascade line could be a significant fraction of the total ventilation. In this two-tank cascade, air evidently flowed from Tank U-103 to Tank U-102 for a time and then was observed to flow from Tank U-102 to Tank U-103

  8. A new method of preparing single-walled carbon nanotubes

    Indian Academy of Sciences (India)

    A novel method of purification for single-walled carbon nanotubes, prepared by an arc-discharge method, is described. The method involves a combination of acid washing followed by high temperature hydrogen treatment to remove the metal nanoparticles and amorphous carbon present in the as-synthesized singlewalled ...

  9. 76 FR 38281 - Federal Employees Health Benefits Program: New Premium Rating Method for Most Community Rated...

    Science.gov (United States)

    2011-06-29

    ... Most Community Rated Plans; Withdrawal; Final Rules #0;#0;Federal Register / Vol. 76 , No. 125... Program: New Premium Rating Method for Most Community Rated Plans; Withdrawal AGENCY: U.S. Office of...

  10. Initial-rate based method for estimating the maximum heterotrophic growth rate parameter (μHmax).

    Science.gov (United States)

    Fall, C; Hooijmans, C M; Esparza-Soto, M; Olguin, M T; Bâ, K M

    2012-07-01

    Currently, the method most used for measuring the maximum specific growth rate (μ(Hmax)) of heterotrophic biomass is by respirometry, using growth batch tests performed at high food/microorganism ratio. No other technique has been suggested, although the former approach was criticized for providing kinetic constants that could be unrepresentative of the original biomass. An alternative method (seed-increments) is proposed, which relies on measuring the initial rates of respiration (r(O2)(_ini)) at different seeding levels, in a single batch, and in the presence of excess readily biodegradable substrate (S(S)). The ASM1-based underlying equations were developed, which showed that μ(Hmax) could be estimated through the slope of the linear function of r(O2)(_ini)·(V(WW)+v(ML)) vs v(ML) (volume of mixed liquor inoculum); V(WW) represent the wastewater volume added. The procedure was tested, being easy to apply; the postulated linearity was constantly observed and the method is claimed to measure the characteristics of the biomass of interest. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. An Abstract Multi-Rate Method for Vehicle Dynamics Simulation

    Science.gov (United States)

    2012-01-01

    given and followed by a summary of the multigrid methods which we seek to emulate. Next, the new abstract multi-rate method and its theoretical...contrast to the sequential temporal nature of a multi-rate method, multigrid methods decompose the entire solution domain. The new abstract multi-rate...computational linear algebra texts such as [8 Demmel]. Multigrid methods are generally applied to boundary value problems. For one dimensional problems, the

  12. High School Graduation Rates:Alternative Methods and Implications

    Directory of Open Access Journals (Sweden)

    Jing Miao

    2004-10-01

    Full Text Available The No Child Left Behind Act has brought great attention to the high school graduation rate as one of the mandatory accountability measures for public school systems. However, there is no consensus on how to calculate the high school graduation rate given the lack of longitudinal databases that track individual students. This study reviews literature on and practices in reporting high school graduation rates, compares graduation rate estimates yielded from alternative methods, and estimates discrepancies between alternative results at national, state, and state ethnic group levels. Despite the graduation rate method used, results indicate that high school graduation rates in the U.S. have been declining in recent years and that graduation rates for black and Hispanic students lag substantially behind those of white students. As to graduation rate method preferred, this study found no evidence that the conceptually more complex methods yield more accurate or valid graduation rate estimates than the simpler methods.

  13. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    Science.gov (United States)

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  14. Finding the right coverage : The impact of coverage and sequence quality on single nucleotide polymorphism genotyping error rates

    NARCIS (Netherlands)

    Fountain, Emily D.; Pauli, Jonathan N.; Reid, Brendan N.; Palsboll, Per J.; Peery, M. Zachariah

    Restriction-enzyme-based sequencing methods enable the genotyping of thousands of single nucleotide polymorphism (SNP) loci in nonmodel organisms. However, in contrast to traditional genetic markers, genotyping error rates in SNPs derived from restriction-enzyme-based methods remain largely unknown.

  15. An Asymmetrical Space Vector Method for Single Phase Induction Motor

    DEFF Research Database (Denmark)

    Cui, Yuanhai; Blaabjerg, Frede; Andersen, Gert Karmisholt

    2002-01-01

    Single phase induction motors are the workhorses in low-power applications in the world, and also the variable speed is necessary. Normally it is achieved either by the mechanical method or by controlling the capacitor connected with the auxiliary winding. Any above method has some drawback which...

  16. Cheap arbitrary high order methods for single integrand SDEs

    DEFF Research Database (Denmark)

    Debrabant, Kristian; Kværnø, Anne

    2017-01-01

    For a particular class of Stratonovich SDE problems, here denoted as single integrand SDEs, we prove that by applying a deterministic Runge-Kutta method of order $p_d$ we obtain methods converging in the mean-square and weak sense with order $\\lfloor p_d/2\\rfloor$. The reason is that the B-series...

  17. Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Feras Sendy

    2015-01-01

    Full Text Available Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67% received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225 of the patients. 28% (63/225 were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63 of failure received a second dose of methotrexate, and 37% (23/63 underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  18. Single-Frame Attitude Determination Methods for Nanosatellites

    Directory of Open Access Journals (Sweden)

    Guler Demet Cilden

    2017-06-01

    Full Text Available Single-frame methods of determining the attitude of a nanosatellite are compared in this study. The methods selected for comparison are: Single Value Decomposition (SVD, q method, Quaternion ESTimator (QUEST, Fast Optimal Attitude Matrix (FOAM − all solving optimally the Wahba’s problem, and the algebraic method using only two vector measurements. For proper comparison, two sensors are chosen for the vector observations on-board: magnetometer and Sun sensors. Covariance results obtained as a result of using those methods have a critical importance for a non-traditional attitude estimation approach; therefore, the variance calculations are also presented. The examined methods are compared with respect to their root mean square (RMS error and variance results. Also, some recommendations are given.

  19. The UIC 406 capacity method used on single track sections

    DEFF Research Database (Denmark)

    Landex, Alex; Kaas, Anders H.; Jacobsen, Erik M.

    2007-01-01

    follow each other in the same direction. Anyway, special care has to be shown to how to expound the UIC 406 capacity method in specific cases. Therefore, this paper discusses where to divide the railway lines into line sections and how crossing stations and junctions and conflicts when entering......This paper describes the relatively new UIC 406 capacity method which is an easy and effective way of calculating capacity consumption on railway lines. However, it is possible to expound the method in different ways which can lead to different capacity consumptions. This paper describes the UIC...... 406 method for single track lines and how it is expounded in Denmark. Many capacity analyses using the UIC 406 capacity method for double track lines have been carried out and presented internationally but only few capacity analyses using the UIC 406 capacity method on single track lines have been...

  20. Compositions and methods for detecting single nucleotide polymorphisms

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Hsin-Chih; Werner, James; Martinez, Jennifer S.

    2016-11-22

    Described herein are nucleic acid based probes and methods for discriminating and detecting single nucleotide variants in nucleic acid molecules (e.g., DNA). The methods include use of a pair of probes can be used to detect and identify polymorphisms, for example single nucleotide polymorphism in DNA. The pair of probes emit a different fluorescent wavelength of light depending on the association and alignment of the probes when hybridized to a target nucleic acid molecule. Each pair of probes is capable of discriminating at least two different nucleic acid molecules that differ by at least a single nucleotide difference. The methods can probes can be used, for example, for detection of DNA polymorphisms that are indicative of a particular disease or condition.

  1. Development of two dimensional electrophoresis method using single chain DNA

    International Nuclear Information System (INIS)

    Ikeda, Junichi; Hidaka, So

    1998-01-01

    By combining a separation method due to molecular weight and a method to distinguish difference of mono-bases, it was aimed to develop a two dimensional single chain DNA labeled with Radioisotope (RI). From electrophoretic pattern difference of parent and variant strands, it was investigated to isolate the root module implantation control gene. At first, a Single Strand Conformation Polymorphism (SSCP) method using concentration gradient gel was investigated. As a result, it was formed that intervals between double chain and single chain DNAs expanded, but intervals of both single chain DNAs did not expand. On next, combination of non-modified acrylic amide electrophoresis method and Denaturing Gradient-Gel Electrophoresis (DGGE) method was examined. As a result, hybrid DNA developed by two dimensional electrophoresis arranged on two lines. But, among them a band of DNA modified by high concentration of urea could not be found. Therefore, in this fiscal year's experiments, no preferable result could be obtained. By the used method, it was thought to be impossible to detect the differences. (G.K.)

  2. Method for harvesting rare earth barium copper oxide single crystals

    Science.gov (United States)

    Todt, Volker R.; Sengupta, Suvankar; Shi, Donglu

    1996-01-01

    A method of preparing high temperature superconductor single crystals. The method of preparation involves preparing precursor materials of a particular composition, heating the precursor material to achieve a peritectic mixture of peritectic liquid and crystals of the high temperature superconductor, cooling the peritectic mixture to quench directly the mixture on a porous, wettable inert substrate to wick off the peritectic liquid, leaving single crystals of the high temperature superconductor on the porous substrate. Alternatively, the peritectic mixture can be cooled to a solid mass and reheated on a porous, inert substrate to melt the matrix of peritectic fluid while leaving the crystals melted, allowing the wicking away of the peritectic liquid.

  3. A New Method to Calculate Internal Rate of Return

    Directory of Open Access Journals (Sweden)

    azadeh zandi

    2015-09-01

    Full Text Available A number of methods have been developed to choose the best capital investment projects such as net present value, internal rate of return and etc. Internal rate of return method is probably the most popular method among managers and investors. But despite the popularity there are serious drawbacks and limitations in this method. After decades of efforts made by economists and experts to improve the method and its shortcomings, Magni in 2010 has revealed a new approach that can solves the most of internal rate of return method problems. This paper present a new method which is originated from Magni’s approach but has much more simple calculations and can resolve all the drawbacks of internal rate of return method.

  4. A Brief Introduction to Single-Molecule Fluorescence Methods.

    Science.gov (United States)

    van den Wildenberg, Siet M J L; Prevo, Bram; Peterman, Erwin J G

    2018-01-01

    One of the more popular single-molecule approaches in biological science is single-molecule fluorescence microscopy, which will be the subject of the following section of this volume. Fluorescence methods provide the sensitivity required to study biology on the single-molecule level, but they also allow access to useful measurable parameters on time and length scales relevant for the biomolecular world. Before several detailed experimental approaches will be addressed, we will first give a general overview of single-molecule fluorescence microscopy. We start with discussing the phenomenon of fluorescence in general and the history of single-molecule fluorescence microscopy. Next, we will review fluorescent probes in more detail and the equipment required to visualize them on the single-molecule level. We will end with a description of parameters measurable with such approaches, ranging from protein counting and tracking, single-molecule localization super-resolution microscopy, to distance measurements with Förster Resonance Energy Transfer and orientation measurements with fluorescence polarization.

  5. Using micro-patterned sensors and cell self-assembly for measuring the oxygen consumption rate of single cells

    International Nuclear Information System (INIS)

    Etzkorn, James R; Parviz, Babak A; Wu, Wen-Chung; Tian, Zhiyuan; Kim, Prince; Jang, Sei-Hum; Jen, Alex K-Y; Meldrum, Deirdre R

    2010-01-01

    We present a method for self-assembling arrays of live single cells on a glass chip using a photopatternable polymer to form micro-traps. We have studied the single-cell self-assembly method and optimized the process to obtain a 52% yield of single-trapped cells. We also report a method to measure the oxygen consumption rate of a single cell using micro-patterned sensors. These molecular oxygen sensors were fabricated around each micro-trap allowing optical interrogation of oxygen concentration in the immediate environment of the trapped cell. Micromachined micro-wells were then used to seal the trap, sensor and cell in order to determine the oxygen consumption rate of single cells. These techniques reported here add to the collection of tools for performing 'singe-cell' biology. An oxygen consumption rate of 1.05 ± 0.28 fmol min −1 was found for a data set consisting of 25 single A549 cells.

  6. Review of methods to probe single cell metabolism and bioenergetics.

    Science.gov (United States)

    Vasdekis, Andreas E; Stephanopoulos, Gregory

    2015-01-01

    Single cell investigations have enabled unexpected discoveries, such as the existence of biological noise and phenotypic switching in infection, metabolism and treatment. Herein, we review methods that enable such single cell investigations specific to metabolism and bioenergetics. Firstly, we discuss how to isolate and immobilize individuals from a cell suspension, including both permanent and reversible approaches. We also highlight specific advances in microbiology for its implications in metabolic engineering. Methods for probing single cell physiology and metabolism are subsequently reviewed. The primary focus therein is on dynamic and high-content profiling strategies based on label-free and fluorescence microspectroscopy and microscopy. Non-dynamic approaches, such as mass spectrometry and nuclear magnetic resonance, are also briefly discussed. Published by Elsevier Inc.

  7. Single particle electrochemical sensors and methods of utilization

    Science.gov (United States)

    Schoeniger, Joseph [Oakland, CA; Flounders, Albert W [Berkeley, CA; Hughes, Robert C [Albuquerque, NM; Ricco, Antonio J [Los Gatos, CA; Wally, Karl [Lafayette, CA; Kravitz, Stanley H [Placitas, NM; Janek, Richard P [Oakland, CA

    2006-04-04

    The present invention discloses an electrochemical device for detecting single particles, and methods for using such a device to achieve high sensitivity for detecting particles such as bacteria, viruses, aggregates, immuno-complexes, molecules, or ionic species. The device provides for affinity-based electrochemical detection of particles with single-particle sensitivity. The disclosed device and methods are based on microelectrodes with surface-attached, affinity ligands (e.g., antibodies, combinatorial peptides, glycolipids) that bind selectively to some target particle species. The electrodes electrolyze chemical species present in the particle-containing solution, and particle interaction with a sensor element modulates its electrolytic activity. The devices may be used individually, employed as sensors, used in arrays for a single specific type of particle or for a range of particle types, or configured into arrays of sensors having both these attributes.

  8. Re-assessing copepod growth using the Moult Rate method

    DEFF Research Database (Denmark)

    Hirst, Andrew G.; Keister, J. E.; Richardson, A. J.

    2014-01-01

    Estimating growth and production rates of mesozooplankton, and copepods in particular, is important in describing flows of material and energy though pelagic systems. Over the past 30 years, the Moult Rate (MR) method has been used to estimate juvenile copepod growth rates in ∼40 papers. Yet the ...

  9. Methods for determination of passage rates of, fibre in tropical ...

    African Journals Online (AJOL)

    Passage rates were estimated in vivo using five rumen fistulated non-pregnant dairy heifers. Rumen evacuation technique (RET), and chromium mordanted fibre (CR-MF) method were used to estimate passage rates in 5 x 5 Latin Square experiment. Passage rates measured using CR-MF and RET showed high variabiltiy ...

  10. Recovery Rate of intestinal parasites using conventional methods in ...

    African Journals Online (AJOL)

    None of the methods could detect all the cases observed in the study alone, thus no single technique was satisfactory as none was equally applicable for trophozoites and cysts of protozoa, eggs or larvae of helminths. Brine flotation technique should be added to the routine diagnostic method (wet preparation), since it ...

  11. A new method of preparing single-walled carbon nanotubes

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 115; Issue 5-6. A new method of preparing single-walled carbon nanotubes ... Jawaharlal Nehru Centre for Advanced Scientific Research, Jakkur PO, Bangalore 560 064, India; Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560 012, ...

  12. A new method of preparing single-walled carbon nanotubes

    Indian Academy of Sciences (India)

    Unknown

    A new method of preparing single-walled carbon nanotubes. ¶. S R C VIVEKCHAND1 and A GOVINDARAJ1,2,*. 1Chemistry and Physics of Materials Unit, Jawaharlal Nehru Centre for. Advanced Scientific Research, Jakkur PO, Bangalore 560 064, India. 2Solid State and Structural Chemistry Unit, Indian Institute of Science ...

  13. METHOD FOR MANUFACTURING A SINGLE CRYSTAL NANO-WIRE.

    NARCIS (Netherlands)

    Van Den Berg, Albert; Bomer, Johan; Carlen Edwin, Thomas; Chen, Songyue; Kraaijenhagen Roderik, Adriaan; Pinedo Herbert, Michael

    2011-01-01

    A method for manufacturing a single crystal nano-structure is provided comprising the steps of providing a device layer with a 100 structure on a substrate; providing a stress layer onto the device layer; patterning the stress layer along the 110 direction of the device layer; selectively removing

  14. METHOD FOR MANUFACTURING A SINGLE CRYSTAL NANO-WIRE

    NARCIS (Netherlands)

    Van Den Berg, Albert; Bomer, Johan; Carlen Edwin, Thomas; Chen, Songyue; Kraaijenhagen Roderik, Adriaan; Pinedo Herbert, Michael

    2012-01-01

    A method for manufacturing a single crystal nano-structure includes providing a device layer with a 100 structure on a substrate; providing a stress layer onto the device layer; patterning the stress layer along the 110 direction of the device layer; selectively removing parts of the stress layer to

  15. Estimation of single-kidney glomerular filtration rate without exogenous contrast agent.

    Science.gov (United States)

    He, Xiang; Aghayev, Ayaz; Gumus, Serter; Ty Bae, K

    2014-01-01

    Measurement of single-kidney filtration fraction and glomerular filtration rate (GFR) without exogenous contrast is clinically important to assess renal function and pathophysiology, especially for patients with comprised renal function. The objective of this study is to develop a novel MR-based tool for noninvasive quantification of renal function using conventional MR arterial spin labeling water as endogenous tracer. The regional differentiation of the arterial spin labeling water between the glomerular capsular space and the renal parenchyma was characterized and measured according to their MR relaxation properties (T1ρ or T2 ), and applied to the estimation of filtration fraction and single-kidney GFR. The proposed approach was tested to quantify GFR in healthy volunteers at baseline and after a protein-loading challenge. Biexponential decay of the cortical arterial spin labeling water MR signal was observed. The major component decays the same as parenchyma water; the minor component decays much slower as expected from glomerular ultra-filtrates. The mean single-kidney GFR was estimated to be 49 ± 9 mL/min at baseline and increased by 28% after a protein-loading challenge. We developed an arterial spin labeling-based MR imaging method that allows us to estimate renal filtration fraction and singe-kidney GFR without use of exogenous contrast. Copyright © 2013 Wiley Periodicals, Inc.

  16. A Network Centrality Method for the Rating Problem

    Science.gov (United States)

    2015-01-01

    We propose a new method for aggregating the information of multiple users rating multiple items. Our approach is based on the network relations induced between items by the rating activity of the users. Our method correlates better than the simple average with respect to the original rankings of the users, and besides, it is computationally more efficient than other methods proposed in the literature. Moreover, our method is able to discount the information that would be obtained adding to the system additional users with a systematically biased rating activity. PMID:25830502

  17. Single Image Super Resolution using a Joint GMM Method.

    Science.gov (United States)

    Sandeep, P; Jacob, Tony

    2016-07-07

    Single Image Super Resolution (SR) algorithms based on joint dictionaries and sparse representations of image patches have received significant attention in literature and deliver state of the art results. Recently, Gaussian Mixture Models (GMMs) have emerged as favored prior for natural image patches in various image restoration problems. In this work, we approach the single image SR problem by using a joint GMM learnt from concatenated vectors of high and low resolution patches sampled from a large database of pairs of high resolution and the corresponding low resolution images. Covariance matrices of the learnt Gaussian models capture the inherent correlations between high and low resolution patches which are utilized for inferring high resolution patches from given low resolution patches. The proposed joint GMM method can be interpreted as the GMM analogue of joint dictionary based algorithms for single image SR. We study the performance of the proposed joint GMM method by comparing with various competing algorithms for single image SR. Our experiments on various natural images demonstrate the competitive performance obtained by the proposed method at low computational cost.

  18. METHODICAL BASES OF ESTIMATION GLOMERULAR FILTRATION RATE IN UROLOGICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    M. M. Batiushin

    2017-01-01

    Full Text Available The article presents a review of methodological issues of estimation of glomerular filtration rate in urologic practice. Author examine the current international and national recommendations, in particular by KDIGO, the recommendations of the scientific society of nephrologists of Russia, Association of urologists of Russia, the results of comparative analysis of different methods of assessing glomerular filtration rate. It is shown that the currently calculated methods of assessment of glomerular filtration rate have advantages over technique of clearance. The advantages and disadvantages of methods for calculating glomerular filtration rate by the formula of Cockcroft-Gault and MDRD. The author lists the pathological conditions in urological practice, in which there is a need to assess glomerular filtration rate, given nomograms and links to online calculators for quick and easy calculation of glomerular filtration rate.

  19. Real stabilization method for nuclear single-particle resonances

    International Nuclear Information System (INIS)

    Zhang Li; Zhou Shangui; Meng Jie; Zhao Enguang

    2008-01-01

    We develop the real stabilization method within the framework of the relativistic mean-field (RMF) model. With the self-consistent nuclear potentials from the RMF model, the real stabilization method is used to study single-particle resonant states in spherical nuclei. As examples, the energies, widths, and wave functions of low-lying neutron resonant states in 120 Sn are obtained. These results are compared with those from the scattering phase-shift method and the analytic continuation in the coupling constant approach and satisfactory agreements are found

  20. High Energy Single Frequency Fiber Laser at Low Repetition Rate, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase II project proposes a single frequency high energy fiber laser system operating at low repetition rate of 10 Hz to 1 kHz for coherent Lidar systems...

  1. Improvement of Source Number Estimation Method for Single Channel Signal.

    Directory of Open Access Journals (Sweden)

    Zhi Dong

    Full Text Available Source number estimation methods for single channel signal have been investigated and the improvements for each method are suggested in this work. Firstly, the single channel data is converted to multi-channel form by delay process. Then, algorithms used in the array signal processing, such as Gerschgorin's disk estimation (GDE and minimum description length (MDL, are introduced to estimate the source number of the received signal. The previous results have shown that the MDL based on information theoretic criteria (ITC obtains a superior performance than GDE at low SNR. However it has no ability to handle the signals containing colored noise. On the contrary, the GDE method can eliminate the influence of colored noise. Nevertheless, its performance at low SNR is not satisfactory. In order to solve these problems and contradictions, the work makes remarkable improvements on these two methods on account of the above consideration. A diagonal loading technique is employed to ameliorate the MDL method and a jackknife technique is referenced to optimize the data covariance matrix in order to improve the performance of the GDE method. The results of simulation have illustrated that the performance of original methods have been promoted largely.

  2. Principles of crystallization, and methods of single crystal growth

    International Nuclear Information System (INIS)

    Chacra, T.

    2010-01-01

    Most of single crystals (monocrystals), have distinguished optical, electrical, or magnetic properties, which make from single crystals, key elements in most of technical modern devices, as they may be used as lenses, Prisms, or grating sin optical devises, or Filters in X-Ray and spectrographic devices, or conductors and semiconductors in electronic, and computer industries. Furthermore, Single crystals are used in transducer devices. Moreover, they are indispensable elements in Laser and Maser emission technology.Crystal Growth Technology (CGT), has started, and developed in the international Universities and scientific institutions, aiming at some of single crystals, which may have significant properties and industrial applications, that can attract the attention of international crystal growth centers, to adopt the industrial production and marketing of such crystals. Unfortunately, Arab universities generally, and Syrian universities specifically, do not give even the minimum interest, to this field of Science.The purpose of this work is to attract the attention of Crystallographers, Physicists and Chemists in the Arab universities and research centers to the importance of crystal growth, and to work on, in the first stage to establish simple, uncomplicated laboratories for the growth of single crystal. Such laboratories can be supplied with equipment, which are partly available or can be manufactured in the local market. Many references (Articles, Papers, Diagrams, etc..) has been studied, to conclude the most important theoretical principles of Phase transitions,especially of crystallization. The conclusions of this study, are summarized in three Principles; Thermodynamic-, Morphologic-, and Kinetic-Principles. The study is completed by a brief description of the main single crystal growth methods with sketches, of equipment used in each method, which can be considered as primary designs for the equipment, of a new crystal growth laboratory. (author)

  3. Single-screw fixation for subtalar joint fusion does not increase nonunion rate.

    Science.gov (United States)

    DeCarbo, William T; Berlet, Gregory C; Hyer, Christopher F; Smith, W Bret

    2010-08-01

    A philosophical shift toward more joint-sparing procedures has led to increased use of isolated subtalar joint (STJ) versus triple arthrodesis. Union rates for STJ fusion range from 47% to 100%, leading to controversy regarding the optimal type, orientation, and amount of internal fixation. The purpose of this study was to determine if single-screw fixation is a predisposing factor to nonunion. Single-screw fixation is parallel to the STJ axis and may result in motion. It is hypothesized that higher nonunion rates will be observed in single-screw versus 2-screw fusions. Isolated STJ arthrodeses performed in 113 patients were retrospectively reviewed. Single screws were used in 89 (78.8%) fusions; 2 screws were used in 24 (21.2%) fusions. The mean follow-up was 11 months (range, 9-17 months). Nonunion occurred in 13 (14.6%) single-screw and 6 (25.0%) 2-screw fusions. Twenty (22.5%) single-screw and 3 (12.5%) 2-screw fusions required hardware removal. Revision surgery was performed in 6 (6.7%) single-screw and 3 (12.5%) 2-screw fusions. No significant differences in demographics were calculated between single and 2-screw fusions. Furthermore, no significant differences were observed in nonunion rate, postoperative complication incidence, or subsequent surgeries. The results from this study do not support the contention that single-screw fixation predisposes STJ fusions to nonunion. Comparable nonunion and complication incidences were observed between single and 2-screw fusions. These data suggest that the motion occurring from single-screw fixation may not be significant enough to directly affect the rate of union.

  4. Oil Reservoir Production Optimization using Single Shooting and ESDIRK Methods

    DEFF Research Database (Denmark)

    Capolei, Andrea; Völcker, Carsten; Frydendall, Jan

    2012-01-01

    the injections and oil production such that flow is uniform in a given geological structure. Even in the case of conventional water flooding, feedback based optimal control technologies may enable higher oil recovery than with conventional operational strategies. The optimal control problems that must be solved......Conventional recovery techniques enable recovery of 10-50% of the oil in an oil field. Advances in smart well technology and enhanced oil recovery techniques enable significant larger recovery. To realize this potential, feedback model-based optimal control technologies are needed to manipulate...... are large-scale problems and require specialized numerical algorithms. In this paper, we combine a single shooting optimization algorithm based on sequential quadratic programming (SQP) with explicit singly diagonally implicit Runge-Kutta (ESDIRK) integration methods and the a continuous adjoint method...

  5. Defects detecting method of lamp cap of single soldering lug

    Science.gov (United States)

    Cai, Jihe; Lv, Jidong

    2017-07-01

    In order to resolve the problems of low efficiency and large separating difference in fault detection of lamp holders with single soldering lug, an image-detection-based defect detection method is presented in this paper. The selected image is first preprocessed, where the possible area of soldering lug is cut in this preprocessing to narrow the scope for subsequent partition with the consideration that the smooth surface of metal at lamp holder and black insulation glass may reflect the light. Then, the soldering lug is extracted by a series of processing including clustering partition. Based on this, the defects are detected by regional marking, area comparison, circularity and coordinate deviation. The experiment results show that the designed method is simple and practical to detect main quality defects of lamp holder with single soldering lug correctly and efficiently.

  6. Methods of forming single source precursors, methods of forming polymeric single source precursors, and single source precursors formed by such methods

    Science.gov (United States)

    Fox, Robert V.; Rodriguez, Rene G.; Pak, Joshua J.; Sun, Chivin; Margulieux, Kelsey R.; Holland, Andrew W.

    2014-09-09

    Methods of forming single source precursors (SSPs) include forming intermediate products having the empirical formula 1/2{L.sub.2N(.mu.-X).sub.2M'X.sub.2}.sub.2, and reacting MER with the intermediate products to form SSPs of the formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2, wherein L is a Lewis base, M is a Group IA atom, N is a Group IB atom, M' is a Group IIIB atom, each E is a Group VIB atom, each X is a Group VIIA atom or a nitrate group, and each R group is an alkyl, aryl, vinyl, (per)fluoro alkyl, (per)fluoro aryl, silane, or carbamato group. Methods of forming polymeric or copolymeric SSPs include reacting at least one of HE.sup.1R.sup.1E.sup.1H and MER with one or more substances having the empirical formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2 or L.sub.2N(.mu.-X).sub.2M'(X).sub.2 to form a polymeric or copolymeric SSP. New SSPs and intermediate products are formed by such methods.

  7. Methods of forming single source precursors, methods of forming polymeric single source precursors, and single source precursors and intermediate products formed by such methods

    Science.gov (United States)

    Fox, Robert V.; Rodriguez, Rene G.; Pak, Joshua J.; Sun, Chivin; Margulieux, Kelsey R.; Holland, Andrew W.

    2012-12-04

    Methods of forming single source precursors (SSPs) include forming intermediate products having the empirical formula 1/2{L.sub.2N(.mu.-X).sub.2M'X.sub.2}.sub.2, and reacting MER with the intermediate products to form SSPs of the formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2, wherein L is a Lewis base, M is a Group IA atom, N is a Group IB atom, M' is a Group IIIB atom, each E is a Group VIB atom, each X is a Group VIIA atom or a nitrate group, and each R group is an alkyl, aryl, vinyl, (per)fluoro alkyl, (per)fluoro aryl, silane, or carbamato group. Methods of forming polymeric or copolymeric SSPs include reacting at least one of HE.sup.1R.sup.1E.sup.1H and MER with one or more substances having the empirical formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2 or L.sub.2N(.mu.-X).sub.2M'(X).sub.2 to form a polymeric or copolymeric SSP. New SSPs and intermediate products are formed by such methods.

  8. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  9. High rate discharge capability of single particle electrode of LiCoO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Dokko, Kaoru [Department of Chemistry and Biotechnology, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501 (Japan); Nakata, Natsuko; Kanamura, Kiyoshi [Department of Applied Chemistry, Tokyo Metropolitan University, 1-1 Minami-ohsawa, Hachioji, Tokyo 192-0397 (Japan)

    2009-04-01

    The electrochemical properties of a single particle of LiCoO{sub 2} (8 {mu}m in diameter) in an organic electrolyte were characterized using a microelectrode technique, and the high rate capability of commercially available micron-sized LiCoO{sub 2} was examined in this study. A Pt microfilament (10 {mu}m in diameter) was attached to the single LiCoO{sub 2} particle in the electrolyte during optical microscope observation, and galvanostatic charge-discharge tests were carried out. The discharge capacity of the single LiCoO{sub 2} particle (8 {mu}m diameter) was 0.157 nA h in the potential range of 3.0-4.2 V vs. Li/Li{sup +}, which was close to the theoretical capacity. The discharge rate capability of the single LiCoO{sub 2} particle was excellent, and the particle exhibited its full-discharge capacity up to a high rate of 30 C (5 nA). The discharge reaction of the single particle was not controlled by the solid-state diffusion of Li{sup +}, but by the charge transfer process at a rate lower than 30 C. The discharge capacity of the particle measured at a high rate of 300 C (50 nA) was 0.12 nA h, which was more than 75% of the full capacity of a single particle. (author)

  10. High rate discharge capability of single particle electrode of LiCoO 2

    Science.gov (United States)

    Dokko, Kaoru; Nakata, Natsuko; Kanamura, Kiyoshi

    The electrochemical properties of a single particle of LiCoO 2 (8 μm in diameter) in an organic electrolyte were characterized using a microelectrode technique, and the high rate capability of commercially available micron-sized LiCoO 2 was examined in this study. A Pt microfilament (10 μm in diameter) was attached to the single LiCoO 2 particle in the electrolyte during optical microscope observation, and galvanostatic charge-discharge tests were carried out. The discharge capacity of the single LiCoO 2 particle (8 μm diameter) was 0.157 nA h in the potential range of 3.0-4.2 V vs. Li/Li +, which was close to the theoretical capacity. The discharge rate capability of the single LiCoO 2 particle was excellent, and the particle exhibited its full-discharge capacity up to a high rate of 30 C (5 nA). The discharge reaction of the single particle was not controlled by the solid-state diffusion of Li +, but by the charge transfer process at a rate lower than 30 C. The discharge capacity of the particle measured at a high rate of 300 C (50 nA) was 0.12 nA h, which was more than 75% of the full capacity of a single particle.

  11. Experimental demonstration of highly anisotropic decay rates of single quantum dots inside photonic crystals

    DEFF Research Database (Denmark)

    Wang, Qin; Stobbe, Søren; Nielsen, Henri Thyrrestrup

    We have systematically measured the variation of the spontaneous emission rate with polarization for self-assembled single quantum dots in two-dimensional photonic crystal membranes and obtained a maximum anisotropy factor of 6 between the decay rates of the two nondegenerate bright exciton states....

  12. Engineering task plan for determining breathing rates in single shell tanks using tracer gas

    International Nuclear Information System (INIS)

    Andersen, J.A.

    1997-01-01

    The testing of single shell tanks to determine breathing rates. Inert tracer gases helium, and sulfur hexafluoride will be injected into the tanks AX-103, BY-105, C-107 and U-103. Periodic samples will be taken over a three month interval to determine actual headspace breathing rates

  13. An alternative method for restoring single-tooth implants.

    Science.gov (United States)

    McArdle, B F; Clarizio, L F

    2001-09-01

    Having laboratory technicians prepare soft-tissue casts and implant abutments with or without concomitant removable temporary prostheses during the restorative phase of single-tooth replacement is an accepted practice. It can, however, result in functional and esthetic intraoral discrepancies. Single-tooth implants can be restored with crowns (like those for natural teeth) fabricated at a dental laboratory on casts obtained from final impressions of prepared implant abutments. In the case reported, the restorative dentist restored the patient's single-tooth implant after taking a transfer impression. He constructed a cast simulating the peri-implant soft tissue with final impression material and prepared the abutment on this model. His dental assistant then fabricated a fixed provisional restoration on the prepared abutment. At the patient's next visit, the dentist torqued the prepared abutment onto the implant, took a final impression and inserted the provisional restoration. A crown was made conventionally at the dental laboratory and cemented in place at the following visit. This alternative method for restoring single-tooth implants enhances esthetics by more accurately simulating marginal gingival architecture. It also improves function by preloading the implant through fixed temporization after the dentist, rather than the laboratory technician, prepares the abutment to the dentist's preferred contours.

  14. Myocardial blood flow rate and capillary permeability for 99mTc-DTPA in patients with angiographically normal coronary arteries. Evaluation of the single-injection, residue detection method with intracoronary indicator bolus injection and the use of a mobile gamma camera

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Kelbaek, H; Efsen, F

    1994-01-01

    The aims of the present study were to quantitate myocardial perfusion and capillary permeability in the human heart by means of the single-injection, residue detection method using a mobile gamma camera. With this method, the intravascular mean transit time and the capillary extraction fraction (E...... capillary permeability area product (PS) were determined. Spontaneous 15 min variations (mean of two values) for the LAD and the CX territory, respectively, gave a mean fpl(LAD) of 74.2 (measurement 1) and 77.8 ml.(100 g.min)-1 (measurement 2) (SD of the difference 7.5 ml.(100 g.min)-1) and fpl(CX) of 82.......7 and 92.1 ml. (100 g.min)-1, respectively (SD of the difference 16.1 ml.(100 g.min)-1), and E(LAD) was 51.0 and 55.7%, respectively (SD of the difference 8.4%), and E(CX) was 52.9 and 50.4%, respectively (SD of the difference 5.9%). During atrial pacing, the rate-pressure product increased by 97...

  15. Gas flow meter and method for measuring gas flow rate

    Science.gov (United States)

    Robertson, Eric P.

    2006-08-01

    A gas flow rate meter includes an upstream line and two chambers having substantially equal, fixed volumes. An adjustable valve may direct the gas flow through the upstream line to either of the two chambers. A pressure monitoring device may be configured to prompt valve adjustments, directing the gas flow to an alternate chamber each time a pre-set pressure in the upstream line is reached. A method of measuring the gas flow rate measures the time required for the pressure in the upstream line to reach the pre-set pressure. The volume of the chamber and upstream line are known and fixed, thus the time required for the increase in pressure may be used to determine the flow rate of the gas. Another method of measuring the gas flow rate uses two pressure measurements of a fixed volume, taken at different times, to determine the flow rate of the gas.

  16. Effect of different rates and methods of benomyl and mancozeb ...

    African Journals Online (AJOL)

    AJB SERVER

    2006-07-22

    Jul 22, 2006 ... Field assessment of different rates and methods of three fungicide applications on delay in senescence. (DS) and grain yield of cowpea during the early and late cropping season of 1999 respectively was conducted. The benomyl treatment applied via the combination of seed and foliar methods at the.

  17. Community-level characteristics associated with variation in rates of homelessness among families and single adults.

    Science.gov (United States)

    Fargo, Jamison D; Munley, Ellen A; Byrne, Thomas H; Montgomery, Ann Elizabeth; Culhane, Dennis P

    2013-12-01

    We modeled rates of family and single-adult homelessness in the United States in metropolitan and nonmetropolitan regions and as a function of community-level demographic, behavioral, health, economic, and safety net characteristics. We entered community-level characteristics and US Department of Housing and Urban Development point-in-time counts for a single night in January 2009 into separate mixed-effects statistical analyses that modeled homelessness rates for 4 subpopulations: families and single adults in metropolitan and nonmetropolitan regions. Community-level factors accounted for 25% to 50% of the variance in homelessness rates across models. In metropolitan regions, alcohol consumption, social support, and several economic indicators were uniquely associated with family homelessness, and drug use and homicide were uniquely associated with single-adult homelessness. In nonmetropolitan regions, life expectancy, religious adherence, unemployment, and rent burden were uniquely associated with family homelessness, and health care access, crime, several economic indicators, and receipt of Supplemental Security Income were uniquely associated with single-adult homelessness. Considering homeless families and single adults separately enabled more precise modeling of associations between homelessness rates and community-level characteristics, indicating targets for interventions to reduce homelessness among these subpopulations.

  18. Double vs single internal thoracic artery harvesting in diabetic patients: role in perioperative infection rate

    Directory of Open Access Journals (Sweden)

    Parolari Alessandro

    2008-06-01

    Full Text Available Abstract Background The aim of this prospective study is to evaluate the role in the onset of surgical site infections of bilateral internal thoracic arteries harvesting in patients with decompensated preoperative glycemia. Methods 81 consecutive patients with uncontrolled diabetes mellitus underwent elective CABG harvesting single or double internal thoracic arteries. Single left ITA was harvested in 41 patients (Group 1, 50.6%, BITAs were harvested in 40 (Group 2, 49.4%. The major clinical end points analyzed in this study were infection rate, type of infection, duration of infection, infection relapse rate and total hospital length of stay. Results Five patients developed sternal SSI in the perioperative period, 2 in group 1 and 3 in group 2 without significant difference. All sternal SSIs were superficial with no sternal dehiscence. The development of infection from the time of surgery took 18.5 ± 2.1 and 7.3 ± 3.0 days for Groups 1 and 2 respectively. The infections were treated with wound irrigation and debridement, and with VAC therapy as well as with antibiotics. The VAC system was removed after a mean of 12.8 ± 5.1 days, when sterilization was achieved. The overall survival estimate at 1 year was 98.7%. Only BMI was a significant predictor of SSI using multivariate stepwise logistic regression analysis (Odds Ratio: 1.34; 95%Conficdence Interval: 1.02–1.83; p value: 0.04. In the model, the use of BITA was not an independent predictor of SSI. Conclusion CABG with bilateral pedicled ITAs grafting could be performed safely even in diabetics with poor preoperative glycaemic control.

  19. All-fiber single-mode high modulation rate pseudorandom-coded laser

    Science.gov (United States)

    Zhang, Xin; Yang, Fang; Liu, Yuan; He, Yan; Hou, Xia; Chen, Weibiao

    2013-12-01

    An all-fiber high modulation speed pseudorandom-coded laser based on master oscillator power amplifier configuration is proposed. We use a high modulation rate distributed feedback laser diode as the seed laser to generate the original pseudorandom pulse train. The modulation rate is 1 Gb/s, which corresponds to a minimum pulse interval of 1 ns. A 1 kHz repetition frequency of 10-order M-sequence pseudorandom pulse train is chosen to balance on-line data processing speed and laser ranging resolution. Then, the pseudorandom pulse train is amplified by two-stage amplifiers to boost the output power. All components used in the amplifiers are built in single mode (SM) fiber, so the final output laser is SM with excellent beam quality. Finally, the peak power of pseudorandom code laser is amplified to 23.6 W from 1.5 mW without wave distortion, corresponding to a gain of 42 dB. The ranging experiment of using the optical fiber delay method indoors shows the transmitter of combining modulated laser diode and multistage fiber amplifiers as a promising solution for developing laser for pseudorandom-coded laser ranging.

  20. A portable respiratory rate estimation system with a passive single-lead electrocardiogram acquisition module.

    Science.gov (United States)

    Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina

    2016-07-27

    Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.

  1. Myocardial blood flow rate and capillary permeability for 99mTc-DTPA in patients with angiographically normal coronary arteries. Evaluation of the single-injection, residue detection method with intracoronary indicator bolus injection and the use of a mobile gamma camera

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Kelbaek, H; Efsen, F

    1994-01-01

    The aims of the present study were to quantitate myocardial perfusion and capillary permeability in the human heart by means of the single-injection, residue detection method using a mobile gamma camera. With this method, the intravascular mean transit time and the capillary extraction fraction (...

  2. Increasing the photon collection rate from a single NV center with a silver mirror

    DEFF Research Database (Denmark)

    Israelsen, Niels Møller; Kumar, Shailesh; Tawfieq, Mahmoud

    2014-01-01

    maintaining a high signal-to-noise ratio. In this work, we use a single nitrogen vacancy center in diamond as a quantum emitter operating at ambient conditions and we demonstrate an increased photon count rate up to a factor of 1.76 by placing a silver mirror fabricated on the end facet of an optical fiber......In the pursuit of realizing quantum optical networks, a large variety of different approaches have been studied to achieve a single photon source on-demand. The common goal for these approaches is to harvest all the emission from a quantum emitter into a single spatial optical mode while...

  3. A method to assign failure rates for piping reliability assessments

    International Nuclear Information System (INIS)

    Gamble, R.M.; Tagart, S.W. Jr.

    1991-01-01

    This paper reports on a simplified method that has been developed to assign failure rates that can be used in reliability and risk studies of piping. The method can be applied on a line-by-line basis by identifying line and location specific attributes that can lead to piping unreliability from in-service degradation mechanisms and random events. A survey of service experience for nuclear piping reliability also was performed. The data from this survey provides a basis for identifying in-service failure attributes and assigning failure rates for risk and reliability studies

  4. Advanced evaluation method of SG TSP BEC hole blockage rate

    International Nuclear Information System (INIS)

    Izumida, Hiroyuki; Nagata, Yasuyuki; Harada, Yutaka; Murakami, Ryuji

    2003-01-01

    In spite of the control of the water chemistry of SG secondary feed-water in PWR-SG, SG TSP BEC holes, which are the flow path of secondary water, are often clogged. In the past, the trending of BEC hole blockage rate has conducted by evaluating ECT original signals and visual inspections. However, the ECT original signals of deposits are diversified, it becomes difficult to analyze them with the existing evaluation method using the ECT original signals. In this regard, we have developed the secondary side visual inspection system, which enables the high-accuracy evaluation of BEC hole blockage rate, and new ECT signal evaluation method. (author)

  5. Underwater Environment SDAP Method Using Multi Single-Beam Sonars

    Directory of Open Access Journals (Sweden)

    Zheping Yan

    2013-01-01

    Full Text Available A new autopilot system for unmanned underwater vehicle (UUV using multi-single-beam sonars is proposed for environmental exploration. The proposed autopilot system is known as simultaneous detection and patrolling (SDAP, which addresses two fundamental challenges: autonomous guidance and control. Autonomous guidance, autonomous path planning, and target tracking are based on the desired reference path which is reconstructed from the sonar data collected from the environmental contour with the predefined safety distance. The reference path is first estimated by using a support vector clustering inertia method and then refined by Bézier curves in order to satisfy the inertia property of the UUV. Differential geometry feedback linearization method is used to guide the vehicle entering into the predefined path while finite predictive stable inversion control algorithm is employed for autonomous target approaching. The experimental results from sea trials have demonstrated that the proposed system can provide satisfactory performance implying its great potential for future underwater exploration tasks.

  6. Single well tracer method to evaluate enhanced recovery

    Science.gov (United States)

    Sheely, Jr., Clyde Q.; Baldwin, Jr., David E.

    1978-01-01

    Data useful to evaluate the effectiveness of or to design an enhanced recovery process (the recovery process involving mobilizing and moving hydrocarbons through a hydrocarbon-bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well) are obtained by a process which comprises sequentially: determining hydrocarbon saturation in the formation in a volume in the formation near a well bore penetrating the formation, injecting sufficient of the mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore penetrating the formation, and determining by the single well tracer method a hydrocarbon saturation profile in a volume from which hydrocarbons are moved. The single well tracer method employed is disclosed by U.S. Pat. No. 3,623,842. The process is useful to evaluate surfactant floods, water floods, polymer floods, CO.sub.2 floods, caustic floods, micellar floods, and the like in the reservoir in much less time at greatly reduced costs, compared to conventional multi-well pilot test.

  7. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  8. Parallel efficient rate control methods for JPEG 2000

    Science.gov (United States)

    Martínez-del-Amor, Miguel Á.; Bruns, Volker; Sparenberg, Heiko

    2017-09-01

    Since the introduction of JPEG 2000, several rate control methods have been proposed. Among them, post-compression rate-distortion optimization (PCRD-Opt) is the most widely used, and the one recommended by the standard. The approach followed by this method is to first compress the entire image split in code blocks, and subsequently, optimally truncate the set of generated bit streams according to the maximum target bit rate constraint. The literature proposes various strategies on how to estimate ahead of time where a block will get truncated in order to stop the execution prematurely and save time. However, none of them have been defined bearing in mind a parallel implementation. Today, multi-core and many-core architectures are becoming popular for JPEG 2000 codecs implementations. Therefore, in this paper, we analyze how some techniques for efficient rate control can be deployed in GPUs. In order to do that, the design of our GPU-based codec is extended, allowing stopping the process at a given point. This extension also harnesses a higher level of parallelism on the GPU, leading to up to 40% of speedup with 4K test material on a Titan X. In a second step, three selected rate control methods are adapted and implemented in our parallel encoder. A comparison is then carried out, and used to select the best candidate to be deployed in a GPU encoder, which gave an extra 40% of speedup in those situations where it was really employed.

  9. Lidar method to estimate emission rates from extended sources

    Science.gov (United States)

    Currently, point measurements, often combined with models, are the primary means by which atmospheric emission rates are estimated from extended sources. However, these methods often fall short in their spatial and temporal resolution and accuracy. In recent years, lidar has emerged as a suitable to...

  10. Obtaining Valid Response Rates: Considerations beyond the Tailored Design Method.

    Science.gov (United States)

    Huang, Judy Y.; Hubbard, Susan M.; Mulvey, Kevin P.

    2003-01-01

    Reports on the use of the tailored design method (TDM) to achieve high survey response in two separate studies of the dissemination of Treatment Improvement Protocols (TIPs). Findings from these two studies identify six factors may have influenced nonresponse, and show that use of TDM does not, in itself, guarantee a high response rate. (SLD)

  11. Seeding method and rate influence on weed suppression in aerobic ...

    African Journals Online (AJOL)

    High weed pressure is amongst the major constraints to the extensive adoption of aerobic rice system as a water-wise technique. Towards developing a sustainable weed management strategy, seeding method and rate may substantially contribute to weed suppression and reduce herbicide use and weeding cost. A trough ...

  12. Iron-based composition for magnetocaloric effect (MCE) applications and method of making a single crystal

    Science.gov (United States)

    Evans, III, Boyd Mccutchen; Kisner, Roger A.; Ludtka, Gail Mackiewicz; Ludtka, Gerard Michael; Melin, Alexander M.; Nicholson, Donald M.; Parish; , Chad M.; Rios, Orlando; Sefat, Athena S.; West, David L.; Wilgen, John B.

    2016-02-09

    A method of making a single crystal comprises heating a material comprising magnetic anisotropy to a temperature T sufficient to form a melt of the material. A magnetic field of at least about 1 Tesla is applied to the melt at the temperature T, where a magnetic free energy difference .DELTA.G.sub.m between different crystallographic axes is greater than a thermal energy kT. While applying the magnetic field, the melt is cooled at a rate of about 30.degree. C./min or higher, and the melt solidifies to form a single crystal of the material.

  13. Prospects for DNA methods to measure human heritable mutation rates

    International Nuclear Information System (INIS)

    Mendelsohn, M.L.

    1985-01-01

    A workshop cosponsored by ICPEMC and the US Department of Energy was held in Alta, Utah, December 9-13, 1984 to examine the extent to which DNA-oriented methods might provide new approaches to the important but intractable problem of measuring mutation rates in control and exposed human populations. The workshop identified and analyzed six DNA methods for detection of human heritable mutation, including several created at the meeting, and concluded that none of the methods combine sufficient feasibility and efficiency to be recommended for general application. 8 refs

  14. Comparison between calculation methods of dose rates in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Vianello, E.A.; Biaggio, M.F.; D R, M.F.; Almeida, C.E. de

    1998-01-01

    In treatments with radiations for gynecologic tumors is necessary to evaluate the quality of the results obtained by different calculation methods for the dose rates on the points of clinical interest (A, rectal, vesicle). The present work compares the results obtained by two methods. The Manual Calibration Method (MCM) tri dimensional (Vianello E., et.al. 1998), using orthogonal radiographs for each patient in treatment, and the Theraplan/T P-11 planning system (Thratonics International Limited 1990) this last one verified experimentally (Vianello et.al. 1996). The results show that MCM can be used in the physical-clinical practice with a percentile difference comparable at the computerized programs. (Author)

  15. Enhanced activity of deoxycytidine kinase after pulsed low dose rate and single dose gamma irradiation

    NARCIS (Netherlands)

    Sigmond, J.; Haveman, J.; Kreder, N. Castro; Loves, W. J.; van Bree, C.; Franken, N. A.; Peters, G. J.

    2006-01-01

    In both pulsed low dose rate (LDR) and single high dose radiation schedules, gemcitabine pretreatment sensitizes tumor cells to radiation. These radiosensitizing effects could be the result of decreased DNA repair. In this study, the effect of irradiation on the deoxycytidine kinase (dCK) needed for

  16. Fundamental limitations in spontaneous emission rate of single-photon sources

    DEFF Research Database (Denmark)

    Bozhevolnyi, Sergey I.; Khurgin, Jacob B.

    2016-01-01

    The rate of single-photon generation by quantum emitters (QEs) can be enhanced by placing a QE inside a resonant structure. This structure can represent an all-dielectric micro-resonator or waveguide and thus be characterized by ultra-low loss and dimensions on the order of wavelength. Or it can ...

  17. Minimum Symbol Error Rate Detection in Single-Input Multiple-Output Channels with Markov Noise

    DEFF Research Database (Denmark)

    Christensen, Lars P.B.

    2005-01-01

    Minimum symbol error rate detection in Single-Input Multiple- Output(SIMO) channels with Markov noise is presented. The special case of zero-mean Gauss-Markov noise is examined closer as it only requires knowledge of the second-order moments. In this special case, it is shown that optimal detection...

  18. Transmission of Single-Channel 16-QAM Data Signals at Terabaud Symbol Rates

    DEFF Research Database (Denmark)

    Richter, Thomas; Palushani, Evarist; Schmidt-Langhorst, Carsten

    2012-01-01

    We present latest results for OTDM transmission systems in combination with digital coherent detection achieving record-high serial data rates in a single-wavelength channel. We show serial data transmission of 5.1 Tb/s (640 GBd) over 80-km and 10.2 Tb/s (1.28 TBd) over 29-km dispersion managed f...

  19. Maximum likelihood phylogenetic estimation from DNA sequences with variable rates over sites: approximate methods.

    Science.gov (United States)

    Yang, Z

    1994-09-01

    Two approximate methods are proposed for maximum likelihood phylogenetic estimation, which allow variable rates of substitution across nucleotide sites. Three data sets with quite different characteristics were analyzed to examine empirically the performance of these methods. The first, called the "discrete gamma model," uses several categories of rates to approximate the gamma distribution, with equal probability for each category. The mean of each category is used to represent all the rates falling in the category. The performance of this method is found to be quite good, and four such categories appear to be sufficient to produce both an optimum, or near-optimum fit by the model to the data, and also an acceptable approximation to the continuous distribution. The second method, called "fixed-rates model", classifies sites into several classes according to their rates predicted assuming the star tree. Sites in different classes are then assumed to be evolving at these fixed rates when other tree topologies are evaluated. Analyses of the data sets suggest that this method can produce reasonable results, but it seems to share some properties of a least-squares pairwise comparison; for example, interior branch lengths in nonbest trees are often found to be zero. The computational requirements of the two methods are comparable to that of Felsenstein's (1981, J Mol Evol 17:368-376) model, which assumes a single rate for all the sites.

  20. Efficient use of single molecule time traces to resolve kinetic rates, models and uncertainties

    Science.gov (United States)

    Schmid, Sonja; Hugel, Thorsten

    2018-03-01

    Single molecule time traces reveal the time evolution of unsynchronized kinetic systems. Especially single molecule Förster resonance energy transfer (smFRET) provides access to enzymatically important time scales, combined with molecular distance resolution and minimal interference with the sample. Yet the kinetic analysis of smFRET time traces is complicated by experimental shortcomings—such as photo-bleaching and noise. Here we recapitulate the fundamental limits of single molecule fluorescence that render the classic, dwell-time based kinetic analysis unsuitable. In contrast, our Single Molecule Analysis of Complex Kinetic Sequences (SMACKS) considers every data point and combines the information of many short traces in one global kinetic rate model. We demonstrate the potential of SMACKS by resolving the small kinetic effects caused by different ionic strengths in the chaperone protein Hsp90. These results show an unexpected interrelation between conformational dynamics and ATPase activity in Hsp90.

  1. Dynamic Raman Spectroelectrochemistry of Single Walled Carbon Nanotubes modified electrodes using a Langmuir-Schaefer method

    OpenAIRE

    Ibáñez, David; Romero, Edna Cecilia; Colina, Álvaro; Heras, Aránzazu

    2014-01-01

    Raman spectroelectrochemistry is a fundamental technique to characterize single walled carbon nanotube (SWCNT) films. In this work, we have performed the study of SWCNT films transferred to a glassy carbon electrode using a Langmuir-Schaefer method. Langmuir balance has allowed us to control the characteristics of the film that can be easily transferred to the electrode support. Time-resolved Raman spectroelectrochemistry experiments at scan rates between 20 and 400 mV s−1 were done in two di...

  2. Quantification of single-kidney glomerular filtration rate with electron-beam computed tomography

    Science.gov (United States)

    Lerman, Lilach O.; Ritman, Erik L.; Pelaez, Laura I.; Sheedy, Patrick F., II; Krier, James D.

    2000-04-01

    The ability to accurately and noninvasively quantify single- kidney GFR could be invaluable for assessment of renal function. We developed a model that enables this measurement with EBCT. To examine the reliability of this method, EBCT renal flow and volume studies after contrast media administration were performed in pigs with unilateral renal artery stenosis (Group 1), controls (Group 2), and simultaneously with inulin clearance (Group 3). Renal flow curves, obtained from the bilateral renal cortex and medulla, depicted transit of the contrast through the vascular and tubular compartments, and were fitted using extended gamma- variate functions. Renal blood flow was calculated as the sum of products of cortical and medullary perfusions and volumes. Normalized GFR (mL/min/cc) was calculated using the rate (maximal slope) of proximal tubular contrast accumulation, and EBCT-GFR as normalized GFR* cortical volume. In Group 1, the decreased GFR of the stenotic kidney correlated well with its decreased volume and RBF, and with the degree of stenosis (r equals -0.99). In Group 3, EBCT-GFR correlated well with inulin clearance (slope 1.1, r equals 0.81). This novel approach can be very useful for quantification of concurrent regional hemodynamics and function in the intact kidneys, in a manner potentially applicable to humans.

  3. Application of semiclassical methods to reaction rate theory

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Rigoberto [Univ. of California, Berkeley, CA (United States)

    1993-11-01

    This work is concerned with the development of approximate methods to describe relatively large chemical systems. This effort has been divided into two primary directions: First, we have extended and applied a semiclassical transition state theory (SCTST) originally proposed by Miller to obtain microcanonical and canonical (thermal) rates for chemical reactions described by a nonseparable Hamiltonian, i.e. most reactions. Second, we have developed a method to describe the fluctuations of decay rates of individual energy states from the average RRKM rate in systems where the direct calculation of individual rates would be impossible. Combined with the semiclassical theory this latter effort has provided a direct comparison to the experimental results of Moore and coworkers. In SCTST, the Hamiltonian is expanded about the barrier and the ``good`` action-angle variables are obtained perturbatively; a WKB analysis of the effectively one-dimensional reactive direction then provides the transmission probabilities. The advantages of this local approximate treatment are that it includes tunneling effects and anharmonicity, and it systematically provides a multi-dimensional dividing surface in phase space. The SCTST thermal rate expression has been reformulated providing increased numerical efficiency (as compared to a naive Boltzmann average), an appealing link to conventional transition state theory (involving a ``prereactive`` partition function depending on the action of the reactive mode), and the ability to go beyond the perturbative approximation.

  4. Statistical methods for thermonuclear reaction rates and nucleosynthesis simulations

    International Nuclear Information System (INIS)

    Iliadis, Christian; Champagne, Art E; Longland, Richard; Coc, Alain; Timmes, F X

    2015-01-01

    Rigorous statistical methods for estimating thermonuclear reaction rates and nucleosynthesis are becoming increasingly established in nuclear astrophysics. The main challenge being faced is that experimental reaction rates are highly complex quantities derived from a multitude of different measured nuclear parameters (e.g., astrophysical S-factors, resonance energies and strengths, particle and γ-ray partial widths). We discuss the application of the Monte Carlo method to two distinct, but related, questions. First, given a set of measured nuclear parameters, how can one best estimate the resulting thermonuclear reaction rates and associated uncertainties? Second, given a set of appropriate reaction rates, how can one best estimate the abundances from nucleosynthesis (i.e., reaction network) calculations? The techniques described here provide probability density functions that can be used to derive statistically meaningful reaction rates and final abundances for any desired coverage probability. Examples are given for applications to s-process neutron sources, core-collapse supernovae, classical novae, and Big Bang nucleosynthesis. (paper)

  5. Single-photon detectors combining high efficiency, high detection rates, and ultra-high timing resolution

    Directory of Open Access Journals (Sweden)

    Iman Esmaeil Zadeh

    2017-11-01

    Full Text Available Single-photon detection with high efficiency, high time resolution, low dark counts, and high photon detection rates is crucial for a wide range of optical measurements. Although efficient detectors have been reported before, combining all performance parameters in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency exceeding 92%, over 150 MHz photon detection rate, and a dark count rate below 130 Hz operated in a Gifford-McMahon cryostat. Furthermore, with careful optimization of the detector design and readout electronics, we reach an ultra-low system timing jitter of 14.80 ps (13.95 ps decoupled while maintaining high detection efficiencies (>75%.

  6. Assay of cerebrospinal fluid protein: a rate biuret method evaluated.

    Science.gov (United States)

    Finley, P R; Williams, R J

    1983-01-01

    We evaluated a rate colorimetric method (Beckman) for measuring total protein in cerebrospinal fluid. The automated instrument we used was Beckman's ASTRA TM. A 100-microL sample of spinal fluid is introduced into the biuret reagent in the reaction cell and the increase in absorbance at 545 nm is monitored for 20.5 s. Solid-state circuits determine the rate of alkaline biuret-protein chelate formation, which is directly proportional to the total protein concentration in the sample. The linear range of measurement is 120 to 7500 mg/L. Day-to-day precision (CV) over the range of 150 to 1200 mg/L ranged from 15.2 to 2.3%. The method was unaffected by radical alteration of the albumin/globulin ratio, but there is a positive interference in the presence of hemoglobin, a suppression in the presence of bilirubin, and no effect by xanthochromia. The method is precise, accurate, rapid, and convenient. The method was compared with the trichloroacetic acid method as performed on the Du Pont aca III, giving a correlation coefficient (r2) of 0.9693. The method is precise, accurate, rapid, and convenient.

  7. Single Longitudinal Mode, High Repetition Rate, Q-switched Ho:YLF Laser for Remote Sensing

    Science.gov (United States)

    Bai, Yingxin; Yu, Jirong; Petzar, Paul; Petros, M.; Chen, Songsheng; Trieu, Bo; Lee, Nyung; Singh, U.

    2009-01-01

    Ho:YLF/LuLiF lasers have specific applications for remote sensing such as wind-speed measurement and carbon dioxide (CO2) concentration measurement in the atmosphere because the operating wavelength (around 2 m) is located in the eye-safe range and can be tuned to the characteristic lines of CO2 absorption and there is strong backward scattering signal from aerosol (Mie scattering). Experimentally, a diode pumped Ho:Tm:YLF laser has been successfully used as the transmitter of coherent differential absorption lidar for the measurement of with a repetition rate of 5 Hz and pulse energy of 75 mJ [1]. For highly precise CO2 measurements with coherent detection technique, a laser with high repetition rate is required to averaging out the speckle effect [2]. In addition, laser efficiency is critically important for the air/space borne lidar applications, because of the limited power supply. A diode pumped Ho:Tm:YLF laser is difficult to efficiently operate in high repetition rate due to the large heat loading and up-conversion. However, a Tm:fiber laser pumped Ho:YLF laser with low heat loading can be operated at high repetition rates efficiently [3]. No matter whether wind-speed or carbon dioxide (CO2) concentration measurement is the goal, a Ho:YLF/LuLiF laser as the transmitter should operate in a single longitudinal mode. Injection seeding is a valid technique for a Q-switched laser to obtain single longitudinal mode operation. In this paper, we will report the new results for a single longitudinal mode, high repetition rate, Q-switched Ho:YLF laser. In order to avoid spectral hole burning and make injection seeding easier, a four mirror ring cavity is designed for single longitudinal mode, high repetition rate Q-switched Ho:YLF laser. The ramp-fire technique is chosen for injection seeding.

  8. Variable dose rate single-arc IMAT delivered with a constant dose rate and variable angular spacing

    International Nuclear Information System (INIS)

    Tang, Grace; Earl, Matthew A; Yu, Cedric X

    2009-01-01

    Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc(TM) deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these techniques are evenly distributed within an arc and are allowed to have different monitor unit (MU) weightings. Therefore, a variable dose-rate (VDR) is required for delivery. Because the VDR requirement complicates the control hardware and software of the linear accelerators (linacs) and prevents most existing linacs from delivering IMAT, we propose an alternative planning approach for IMAT using constant dose-rate (CDR) delivery with variable angular spacing. We prove the equivalence by converting VDR-optimized RapidArc plans to CDR plans, where the evenly spaced beams in the VDR plan are redistributed to uneven spacing such that the segments with larger MU weighting occupy a greater angular interval. To minimize perturbation in the optimized dose distribution, the angular deviation of the segments was restricted to ≤± 5 deg. This restriction requires the treatment arc to be broken into multiple sectors such that the local MU fluctuation within each sector is reduced, thereby lowering the angular deviation of the segments during redistribution. The converted CDR plans were delivered with a single gantry sweep as in the VDR plans but each sector was delivered with a different value of CDR. For four patient cases, including two head-and-neck, one brain and one prostate, all CDR plans developed with the variable spacing scheme produced similar dose distributions to the original VDR plans. For plans with complex angular MU distributions, the number of sectors increased up to four in the CDR plans in order to maintain the original plan quality. Since each sector was

  9. Long-term effects and colectomy rates in ulcerative colitis patients treated with infliximab: A Danish single center experience

    DEFF Research Database (Denmark)

    Teisner, A.S.; Ainsworth, M.A.; Brynskov, J.

    2010-01-01

    Objective. Infliximab (IFX) is a well-established treatment for both acute, severe ulcerative colitis (UC) and chronic, refractory UC. However, data on the long-term clinical outcome and colectomy rates after IFX treatment in a routine clinical setting are sparse. The aim of this study...... was to provide further data on the long-term effect of IFX for acute, severe and chronic, refractory UC in unselected patients treated at a single center. Material and Methods. A retrospective analysis of all patients (n = 52) treated with IFX for UC before February 2009 was performed. The material comprised 19...... patients (37%) with acute, severe UC and 33 patients (63%) with chronic, refractory UC. The primary outcome was colectomy rate; the secondary outcome clinical response. Results. The overall colectomy rate was 27% (14/52 patients) after a median follow-up of 22 months (range 4-57 months). The colectomy rate...

  10. A comparison of surveillance methods for small incidence rates

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Woodall, William H.; Reynolds, Marion R.

    2008-05-15

    A number of methods have been proposed to detect an increasing shift in the incidence rate of a rare health event, such as a congenital malformation. Among these are the Sets method, two modifcations of the Sets method, and the CUSUM method based on the Poisson distribution. We consider the situation where data are observed as a sequence of Bernoulli trials and propose the Bernoulli CUSUM chart as a desirable method for the surveillance of rare health events. We compare the performance of the Sets method and its modifcations to the Bernoulli CUSUM chart under a wide variety of circumstances. Chart design parameters were chosen to satisfy a minimax criteria.We used the steady- state average run length to measure chart performance instead of the average run length which was used in nearly all previous comparisons involving the Sets method or its modifcations. Except in a very few instances, we found that the Bernoulli CUSUM chart has better steady-state average run length performance than the Sets method and its modifcations for the extensive number of cases considered.

  11. Basis for dose rate to curie assay method

    Energy Technology Data Exchange (ETDEWEB)

    Gedeon, S.R.

    1996-10-31

    Disposition of low-level solid waste packages at the Hanford Site requires quantifying the radioactive contents of each container. This study generated conversion factors to apply to the results of contact surveys that are performed with standard dose rate survey instruments by field health physics technicians. This study determined the accuracy of this method, and identified the major sources of uncertainty. It is concluded that the dominant error is associated with the possibility that the radioactive source is not homogeneously distributed.

  12. A High-Rate, Single-Crystal Model including Phase Transformations, Plastic Slip, and Twinning

    Energy Technology Data Exchange (ETDEWEB)

    Addessio, Francis L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Theoretical Division; Bronkhorst, Curt Allan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Theoretical Division; Bolme, Cynthia Anne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Explosive Science and Shock Physics Division; Brown, Donald William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology Division; Cerreta, Ellen Kathleen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology Division; Lebensohn, Ricardo A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology Division; Lookman, Turab [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Theoretical Division; Luscher, Darby Jon [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Theoretical Division; Mayeur, Jason Rhea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Theoretical Division; Morrow, Benjamin M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology Division; Rigg, Paulo A. [Washington State Univ., Pullman, WA (United States). Dept. of Physics. Inst. for Shock Physics

    2016-08-09

    An anisotropic, rate-­dependent, single-­crystal approach for modeling materials under the conditions of high strain rates and pressures is provided. The model includes the effects of large deformations, nonlinear elasticity, phase transformations, and plastic slip and twinning. It is envisioned that the model may be used to examine these coupled effects on the local deformation of materials that are subjected to ballistic impact or explosive loading. The model is formulated using a multiplicative decomposition of the deformation gradient. A plate impact experiment on a multi-­crystal sample of titanium was conducted. The particle velocities at the back surface of three crystal orientations relative to the direction of impact were measured. Molecular dynamics simulations were conducted to investigate the details of the high-­rate deformation and pursue issues related to the phase transformation for titanium. Simulations using the single crystal model were conducted and compared to the high-­rate experimental data for the impact loaded single crystals. The model was found to capture the features of the experiments.

  13. Semi-Automatic Rating Method for Neutrophil Alkaline Phosphatase Activity.

    Science.gov (United States)

    Sugano, Kanae; Hashi, Kotomi; Goto, Misaki; Nishi, Kiyotaka; Maeda, Rie; Kono, Keigo; Yamamoto, Mai; Okada, Kazunori; Kaga, Sanae; Miwa, Keiko; Mikami, Taisei; Masauzi, Nobuo

    2017-01-01

    The neutrophil alkaline phosphatase (NAP) score is a valuable test for the diagnosis of myeloproliferative neoplasms, but it has still manually rated. Therefore, we developed a semi-automatic rating method using Photoshop ® and Image-J, called NAP-PS-IJ. Neutrophil alkaline phosphatase staining was conducted with Tomonaga's method to films of peripheral blood taken from three healthy volunteers. At least 30 neutrophils with NAP scores from 0 to 5+ were observed and taken their images. From which the outer part of neutrophil was removed away with Image-J. These were binarized with two different procedures (P1 and P2) using Photoshop ® . NAP-positive area (NAP-PA) and granule (NAP-PGC) were measured and counted with Image-J. The NAP-PA in images binarized with P1 significantly (P < 0.05) differed between images with NAP scores from 0 to 3+ (group 1) and those from 4+ to 5+ (group 2). The original images in group 1 were binarized with P2. NAP-PGC of them significantly (P < 0.05) differed among all four NAP score groups. The mean NAP-PGC with NAP-PS-IJ indicated a good correlation (r = 0.92, P < 0.001) to results by human examiners. The sensitivity and specificity of NAP-PS-IJ were 60% and 92%, which might be considered as a prototypic method for the full-automatic rating NAP score. © 2016 Wiley Periodicals, Inc.

  14. Laypersons' ratings of appearance in children with and without single-suture craniosynostosis.

    Science.gov (United States)

    Collett, Brent R; Gray, Kristen E; Kapp-Simon, Kathleen A; Birgfeld, Craig; Cunningham, Michael; Rudo-Stern, Jenna; Ung, Danielle; Buono, Lauren; Speltz, Matthew L

    2013-07-01

    Single-suture craniosynostosis (SSC) results in head shape anomalies that likely affect social perceptions of appearance. The purpose of this study was to evaluate laypersons' ratings of attractiveness in children with and without SSC. Among cases, we also examined differences by suture fused and age at surgery. We collected photographs of 196 children with SSC and 186 children without SSC as infants (before surgery, for cases) and at ages 18 and 36 months. Photographs were rated by 8 raters, who were blinded to the population being studied. We used linear regression to compare appearance ratings for the 2 groups at each visit and to evaluate changes over time. Regression analyses were used to examine the association between age at surgery and appearance ratings. Children with SSC received lower appearance ratings than unaffected controls at each visit (all P Appearance ratings decreased over time, with a similar trajectory for children with and without SSC. Among cases, those with unicoronal and lambdoid synostosis had the lowest ratings and those with sagittal synostosis had the highest. Age at surgery was inversely associated with appearance ratings. Children with SSC received lower appearance ratings than unaffected controls, with minimal change after surgery. Better outcomes were associated with earlier surgery. These findings do not indicate that children with SSC failed to benefit from surgery, as without surgical intervention, asymmetrical head shape would likely have worsened over time. However, our data suggest that appearance does not fully "normalize."

  15. Viscous slip coefficients for binary gas mixtures measured from mass flow rates through a single microtube

    OpenAIRE

    Yamaguchi, H.; Takamori, K.; Perrier, P.; Graur, I.; Matsuda, Y.; Niimi, T.

    2016-01-01

    The viscous slip coefficient for helium-argon binary gas mixture is extracted from the experimental values of the mass flow rate through a microtube. The mass flow rate is measured by the constant-volume method. The viscous slip coefficient was obtained by identifying the measured mass flow rate through a microtube with the corresponding analytical expression, which is a function of the Knudsen number. The measurements were carried out in the slip flow regime where the first-order slip bounda...

  16. RCS Leak Rate Calculation with High Order Least Squares Method

    International Nuclear Information System (INIS)

    Lee, Jeong Hun; Kang, Young Kyu; Kim, Yang Ki

    2010-01-01

    As a part of action items for Application of Leak before Break(LBB), RCS Leak Rate Calculation Program is upgraded in Kori unit 3 and 4. For real time monitoring of operators, periodic calculation is needed and corresponding noise reduction scheme is used. This kind of study was issued in Korea, so there have upgraded and used real time RCS Leak Rate Calculation Program in UCN unit 3 and 4 and YGN unit 1 and 2. For reduction of the noise in signals, Linear Regression Method was used in those programs. Linear Regression Method is powerful method for noise reduction. But the system is not static with some alternative flow paths and this makes mixed trend patterns of input signal values. In this condition, the trend of signal and average of Linear Regression are not entirely same pattern. In this study, high order Least squares Method is used to follow the trend of signal and the order of calculation is rearranged. The result of calculation makes reasonable trend and the procedure is physically consistence

  17. Dynamically Switching among Bundled and Single Tickets with Time-Dependent Demand Rates

    Directory of Open Access Journals (Sweden)

    Serhan Duran

    2012-01-01

    Full Text Available The most important market segmentation in sports and entertainment industry is the competition between customers that buy bundled and single tickets. A common selling practice is starting the selling season with bundled ticket sales and switching to selling single tickets later on. The aim of this practice is to increase the number of customers that buy bundles, which in return increases the load factor of the events with low demand. In this paper, we investigate the effect of time dependent demand on dynamic switching times from bundled to single ticket sales and the potential revenue gain over the case where the demand rate of events is assumed to be constant with time.

  18. Microscale consolidation analysis of relaxation behavior of single living chondrocytes subjected to varying strain-rates.

    Science.gov (United States)

    Nguyen, Trung Dung; Oloyede, Adekunle; Singh, Sanjleena; Gu, YuanTong

    2015-09-01

    Besides the elastic stiffness, the relaxation behavior of single living cells is also of interest of various researchers when studying cell mechanics. It is hypothesized that the relaxation response of the cells is governed by both intrinsic viscoelasticity of the solid phase and fluid-solid interactions mechanisms. There are a number of mechanical models have been developed to investigate the relaxation behavior of single cells. However, there is lack of model enable to accurately capture both of the mechanisms. Therefore, in this study, the porohyperelastic (PHE) model, which is an extension of the consolidation theory, combined with inverse Finite Element Analysis (FEA) technique was used at the first time to investigate the relaxation response of living chondrocytes. This model was also utilized to study the dependence of relaxation behavior of the cells on strain-rates. The stress-relaxation experiments under the various strain-rates were conducted with the Atomic Force Microscopy (AFM). The results have demonstrated that the PHE model could effectively capture the stress-relaxation behavior of the living chondrocytes, especially at intermediate to high strain-rates. Although this model gave some errors at lower strain-rates, its performance was acceptable. Therefore, the PHE model is properly a promising model for single cell mechanics studies. Moreover, it has been found that the hydraulic permeability of living chondrocytes reduced with decreasing of strain-rates. It might be due to the intracellular fluid volume fraction and the fluid pore pressure gradients of chondrocytes were higher when higher strain-rates applied. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Reducing twin pregnancy rates after IVF--elective single embryo transfer (eSET).

    LENUS (Irish Health Repository)

    Milne, P

    2010-01-01

    Multiple pregnancy is a major complication of IVF and is associated with increased maternal, fetal and neonatal morbidity. Elective single embryo transfer (eSET) during IVF, rather than the more standard transfer of two embryos (double embryo transfer or DET), has been shown to significantly reduce the multiple pregnancy rate associated with IVF, while maintaining acceptable pregnancy rates. Couples undergoing IVF in 2008 who met good prognostic criteria had eSET performed. Pregnancy and twinning rates were compared with those for similar couples in 2007 who had DET. Couples unsuccessful with a fresh cycle of treatment had subsequent frozen embryo transfer cycles with DET. The cumulative pregnancy rate was similar for each group. However there were no multiple pregnancies in the eSET group, compared to 4 twins of 5 pregnancies in the DET group. 96% of eligible couples agreed to eSET. ESET is successful in and acceptable to good prognosis Irish couples undergoing IVF.

  20. Apparatus and method for determining solids circulation rate

    Science.gov (United States)

    Ludlow, J Christopher [Morgantown, WV; Spenik, James L [Morgantown, WV

    2012-02-14

    The invention relates to a method of determining bed velocity and solids circulation rate in a standpipe experiencing a moving packed bed flow, such as the in the standpipe section of a circulating bed fluidized reactor The method utilizes in-situ measurement of differential pressure over known axial lengths of the standpipe in conjunction with in-situ gas velocity measurement for a novel application of Ergun equations allowing determination of standpipe void fraction and moving packed bed velocity. The method takes advantage of the moving packed bed property of constant void fraction in order to integrate measured parameters into simultaneous solution of Ergun-based equations and conservation of mass equations across multiple sections of the standpipe.

  1. Span length and information rate optimisation in optical transmission systems using single-channel digital backpropagation.

    Science.gov (United States)

    Karanov, Boris; Xu, Tianhua; Shevchenko, Nikita A; Lavery, Domaniç; Killey, Robert I; Bayvel, Polina

    2017-10-16

    The optimisation of span length when designing optical communication systems is important from both performance and cost perspectives. In this paper, the optimisation of inter-amplifier spacing and the potential increase of span length at fixed information rates in optical communication systems with practically feasible nonlinearity compensation schemes have been investigated. It is found that in DP-16QAM, DP-64QAM and DP-256QAM systems with practical transceiver noise limitations, single-channel digital backpropagation can allow a 50% reduction in the number of amplifiers without sacrificing information rates compared to systems with optimal span lengths and linear compensation.

  2. Single molecule approaches for quantifying transcription and degradation rates in intact mammalian tissues.

    Science.gov (United States)

    Bahar Halpern, Keren; Itzkovitz, Shalev

    2016-04-01

    A key challenge in mammalian biology is to understand how rates of transcription and mRNA degradation jointly shape cellular gene expression. Powerful techniques have been developed for measuring these rates either genome-wide or at the single-molecule level, however these techniques are not applicable to assessment of cells within their native tissue microenvironment. Here we describe a technique based on single molecule Fluorescence in-situ Hybridization (smFISH) to measure transcription and degradation rates in intact mammalian tissues. The technique is based on dual-color libraries targeting the introns and exons of the genes of interest, enabling visualization and quantification of both nascent and mature mRNA. We present a software, TransQuant, that facilitates quantifying these rates from smFISH images. Our approach enables assessment of both transcription and degradation rates of any gene of interest while controlling for the inherent heterogeneity of intact tissues. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Measurement of the single π0 production rate in neutral current neutrino interactions on water

    Science.gov (United States)

    Abe, K.; Amey, J.; Andreopoulos, C.; Antonova, M.; Aoki, S.; Ariga, A.; Ashida, Y.; Assylbekov, S.; Autiero, D.; Ban, S.; Barbi, M.; Barker, G. J.; Barr, G.; Barry, C.; Bartet-Friburg, P.; Batkiewicz, M.; Berardi, V.; Berkman, S.; Bhadra, S.; Bienstock, S.; Blondel, A.; Bolognesi, S.; Bordoni, S.; Boyd, S. B.; Brailsford, D.; Bravar, A.; Bronner, C.; Buizza Avanzini, M.; Calland, R. G.; Campbell, T.; Cao, S.; Cartwright, S. L.; Castillo, R.; Catanesi, M. G.; Cervera, A.; Chappell, A.; Checchia, C.; Cherdack, D.; Chikuma, N.; Christodoulou, G.; Clifton, A.; Coleman, J.; Collazuol, G.; Coplowe, D.; Cremonesi, L.; Cudd, A.; Dabrowska, A.; De Rosa, G.; Dealtry, T.; Denner, P. F.; Dennis, S. R.; Densham, C.; Dewhurst, D.; Di Lodovico, F.; Di Luise, S.; Dolan, S.; Drapier, O.; Duffy, K. E.; Dumarchez, J.; Dunkman, M.; Dunne, P.; Dziewiecki, M.; Emery-Schrenk, S.; Ereditato, A.; Feusels, T.; Finch, A. J.; Fiorentini, G. A.; Friend, M.; Fujii, Y.; Fukuda, D.; Fukuda, Y.; Furmanski, A. P.; Galymov, V.; Garcia, A.; Giffin, S. G.; Giganti, C.; Gilje, K.; Gizzarelli, F.; Golan, T.; Gonin, M.; Grant, N.; Hadley, D. R.; Haegel, L.; Haigh, J. T.; Hamilton, P.; Hansen, D.; Harada, J.; Hara, T.; Hartz, M.; Hasegawa, T.; Hastings, N. C.; Hayashino, T.; Hayato, Y.; Helmer, R. L.; Hierholzer, M.; Hillairet, A.; Himmel, A.; Hiraki, T.; Hiramoto, A.; Hirota, S.; Hogan, M.; Holeczek, J.; Hosomi, F.; Huang, K.; Ichikawa, A. K.; Ieki, K.; Ikeda, M.; Imber, J.; Insler, J.; Intonti, R. A.; Irvine, T. J.; Ishida, T.; Ishii, T.; Iwai, E.; Iwamoto, K.; Izmaylov, A.; Jacob, A.; Jamieson, B.; Jiang, M.; Johnson, S.; Jo, J. H.; Jonsson, P.; Jung, C. K.; Kabirnezhad, M.; Kaboth, A. C.; Kajita, T.; Kakuno, H.; Kameda, J.; Karlen, D.; Karpikov, I.; Katori, T.; Kearns, E.; Khabibullin, M.; Khotjantsev, A.; Kielczewska, D.; Kikawa, T.; Kim, H.; Kim, J.; King, S.; Kisiel, J.; Knight, A.; Knox, A.; Kobayashi, T.; Koch, L.; Koga, T.; Koller, P. P.; Konaka, A.; Kondo, K.; Kopylov, A.; Kormos, L. L.; Korzenev, A.; Koshio, Y.; Kowalik, K.; Kropp, W.; Kudenko, Y.; Kurjata, R.; Kutter, T.; Lagoda, J.; Lamont, I.; Lamoureux, M.; Larkin, E.; Lasorak, P.; Laveder, M.; Lawe, M.; Lazos, M.; Licciardi, M.; Lindner, T.; Liptak, Z. J.; Litchfield, R. P.; Li, X.; Longhin, A.; Lopez, J. P.; Lou, T.; Ludovici, L.; Lu, X.; Magaletti, L.; Mahn, K.; Malek, M.; Manly, S.; Maret, L.; Marino, A. D.; Marteau, J.; Martin, J. F.; Martins, P.; Martynenko, S.; Maruyama, T.; Matveev, V.; Mavrokoridis, K.; Ma, W. Y.; Mazzucato, E.; McCarthy, M.; McCauley, N.; McFarland, K. S.; McGrew, C.; Mefodiev, A.; Metelko, C.; Mezzetto, M.; Mijakowski, P.; Minamino, A.; Mineev, O.; Mine, S.; Missert, A.; Miura, M.; Moriyama, S.; Morrison, J.; Mueller, Th. A.; Murphy, S.; Myslik, J.; Nakadaira, T.; Nakahata, M.; Nakamura, K. G.; Nakamura, K.; Nakamura, K. D.; Nakanishi, Y.; Nakayama, S.; Nakaya, T.; Nakayoshi, K.; Nantais, C.; Nielsen, C.; Nirkko, M.; Nishikawa, K.; Nishimura, Y.; Novella, P.; Nowak, J.; O'Keeffe, H. M.; Ohta, R.; Okumura, K.; Okusawa, T.; Oryszczak, W.; Oser, S. M.; Ovsyannikova, T.; Owen, R. A.; Oyama, Y.; Palladino, V.; Palomino, J. L.; Paolone, V.; Patel, N. D.; Paudyal, P.; Pavin, M.; Payne, D.; Perkin, J. D.; Petrov, Y.; Pickard, L.; Pickering, L.; Pinzon Guerra, E. S.; Pistillo, C.; Popov, B.; Posiadala-Zezula, M.; Poutissou, J.-M.; Poutissou, R.; Pritchard, A.; Przewlocki, P.; Quilain, B.; Radermacher, T.; Radicioni, E.; Ratoff, P. N.; Ravonel, M.; Rayner, M. A.; Redij, A.; Reinherz-Aronis, E.; Riccio, C.; Rojas, P.; Rondio, E.; Rossi, B.; Roth, S.; Rubbia, A.; Ruggeri, A. C.; Rychter, A.; Sacco, R.; Sakashita, K.; Sánchez, F.; Sato, F.; Scantamburlo, E.; Scholberg, K.; Schwehr, J.; Scott, M.; Seiya, Y.; Sekiguchi, T.; Sekiya, H.; Sgalaberna, D.; Shah, R.; Shaikhiev, A.; Shaker, F.; Shaw, D.; Shiozawa, M.; Shirahige, T.; Short, S.; Smy, M.; Sobczyk, J. T.; Sobel, H.; Sorel, M.; Southwell, L.; Stamoulis, P.; Steinmann, J.; Stewart, T.; Stowell, P.; Suda, Y.; Suvorov, S.; Suzuki, A.; Suzuki, K.; Suzuki, S. Y.; Suzuki, Y.; Tacik, R.; Tada, M.; Takahashi, S.; Takeda, A.; Takeuchi, Y.; Tamura, R.; Tanaka, H. K.; Tanaka, H. A.; Terhorst, D.; Terri, R.; Thakore, T.; Thompson, L. F.; Tobayama, S.; Toki, W.; Tomura, T.; Touramanis, C.; Tsukamoto, T.; Tzanov, M.; Uchida, Y.; Vacheret, A.; Vagins, M.; Vallari, Z.; Vasseur, G.; Vilela, C.; Vladisavljevic, T.; Wachala, T.; Wakamatsu, K.; Walter, C. W.; Wark, D.; Warzycha, W.; Wascko, M. O.; Weber, A.; Wendell, R.; Wilkes, R. J.; Wilking, M. J.; Wilkinson, C.; Wilson, J. R.; Wilson, R. J.; Wret, C.; Yamada, Y.; Yamamoto, K.; Yamamoto, M.; Yanagisawa, C.; Yano, T.; Yen, S.; Yershov, N.; Yokoyama, M.; Yoo, J.; Yoshida, K.; Yuan, T.; Yu, M.; Zalewska, A.; Zalipska, J.; Zambelli, L.; Zaremba, K.; Ziembicki, M.; Zimmerman, E. D.; Zito, M.; Żmuda, J.; T2K Collaboration

    2018-02-01

    The single π0 production rate in neutral current neutrino interactions on water in a neutrino beam with a peak neutrino energy of 0.6 GeV has been measured using the PØD, one of the subdetectors of the T2K near detector. The production rate was measured for data taking periods when the PØD contained water (2.64 ×1020 protons-on-target) and also periods without water (3.49 ×1020 protons-on-target). A measurement of the neutral current single π0 production rate on water is made using appropriate subtraction of the production rate with water in from the rate with water out of the target region. The subtraction analysis yields 106 ±41 ±69 signal events where the uncertainties are statistical (stat.) and systematic (sys.) respectively. This is consistent with the prediction of 157 events from the nominal simulation. The measured to expected ratio is 0.68 ±0.26 (stat ) ±0.44 (sys ) ±0.12 (flux ) . The nominal simulation uses a flux integrated cross section of 7.63 ×10-39 cm2 per nucleon with an average neutrino interaction energy of 1.3 GeV.

  4. Learning rate and attractor size of the single-layer perceptron

    International Nuclear Information System (INIS)

    Singleton, Martin S.; Huebler, Alfred W.

    2007-01-01

    We study the simplest possible order one single-layer perceptron with two inputs, using the delta rule with online learning, in order to derive closed form expressions for the mean convergence rates. We investigate the rate of convergence in weight space of the weight vectors corresponding to each of the 14 out of 16 linearly separable rules. These vectors follow zigzagging lines through the piecewise constant vector field to their respective attractors. Based on our studies, we conclude that a single-layer perceptron with N inputs will converge in an average number of steps given by an Nth order polynomial in (t/l), where t is the threshold, and l is the size of the initial weight distribution. Exact values for these averages are provided for the five linearly separable classes with N=2. We also demonstrate that the learning rate is determined by the attractor size, and that the attractors of a single-layer perceptron with N inputs partition R N +R N

  5. Determination of heterogeneous medium parameters by single fuel element method

    International Nuclear Information System (INIS)

    Veloso, M.A.F.

    1985-01-01

    The neutron pulse propagation technique was employed to study an heterogeneous system consisting of a single fuel element placed at the symmetry axis of a large cylindrical D 2 O tank. The response of system for the pulse propagation technique is related to the inverse complex relaxation length of the neutron waves also known as the system dispersion law ρ (ω). Experimental values of ρ (ω) were compared with the ones derived from Fermi age - Diffusion theory. The main purpose of the experiment was to obtain the Feinberg-Galanin thermal constant (γ), which is the logaritmic derivative of the neutron flux at the fuel-moderator interface and a such a main input data for heterogeneous reactor theory calculations. The γ thermal constant was determined as the number giving the best agreement between the theoretical and experimental values of ρ (ω). The simultaneous determination of two among four parameters η,ρ,τ and L s is possible through the intersection of dispersion laws of the pure moderator system and the fuel moderator system. The parameters τ and η were termined by this method. It was shown that the thermal constant γ and the product η ρ can be computed from the real and imaginary parts of the fuel-moderator dispersion law. The results for this evaluation scheme showns a not stable behavior of γ as a function of frequency, a result not foreseen by the theoretical model. (Author) [pt

  6. Deformation rate controls elasticity and unfolding pathway of single tropocollagen molecules.

    Science.gov (United States)

    Gautieri, Alfonso; Buehler, Markus J; Redaelli, Alberto

    2009-04-01

    Collagen is an important structural protein in vertebrates and is responsible for the integrity of many tissues like bone, teeth, cartilage and tendon. The mechanical properties of these tissues are primarily determined by their hierarchical arrangement and the role of the collagen matrix in their structures. Here we report a series of Steered Molecular Dynamics (SMD) simulations in explicit solvent, used to elucidate the influence of the pulling rate on the Young's modulus of individual tropocollagen molecules. We stretch a collagen peptide model sequence [(Gly-Pro-Hyp)(10)](3) with pulling rates ranging from 0.01 to 100 m/s, reaching much smaller deformation rates than reported in earlier SMD studies. Our results clearly demonstrate a strong influence of the loading velocity on the observed mechanical properties. Most notably, we find that Young's modulus converges to a constant value of approximately 4 GPa tangent modulus at 8% tensile strain when the initially crimped molecule is straightened out, for pulling rates below 0.5 m/s. This enables us for the first time to predict the elastic properties of a single tropocollagen molecule at physiologically and experimentally relevant pulling rates, directly from atomistic-level calculations. At deformation rates larger than 0.5 m/s, Young's modulus increases continuously and approaches values in excess of 15 GPa for deformation rates larger than 100 m/s. The analyses of the molecular deformation mechanisms show that the tropocollagen molecule unfolds in distinctly different ways, depending on the loading rate, which explains the observation of different values of Young's modulus at different loading rates. For low pulling rates, the triple helix first uncoils completely at 10%-20% strain, then undergoes some recoiling in the opposite direction, and finally straightens for strains larger than 30%. At intermediate rates, the molecule uncoils linearly with increasing strain up to 35% strain. Finally, at higher

  7. Scale factor measure method without turntable for angular rate gyroscope

    Science.gov (United States)

    Qi, Fangyi; Han, Xuefei; Yao, Yanqing; Xiong, Yuting; Huang, Yuqiong; Wang, Hua

    2018-03-01

    In this paper, a scale factor test method without turntable is originally designed for the angular rate gyroscope. A test system which consists of test device, data acquisition circuit and data processing software based on Labview platform is designed. Taking advantage of gyroscope's sensitivity of angular rate, a gyroscope with known scale factor, serves as a standard gyroscope. The standard gyroscope is installed on the test device together with a measured gyroscope. By shaking the test device around its edge which is parallel to the input axis of gyroscope, the scale factor of the measured gyroscope can be obtained in real time by the data processing software. This test method is fast. It helps test system miniaturized, easy to carry or move. Measure quarts MEMS gyroscope's scale factor multi-times by this method, the difference is less than 0.2%. Compare with testing by turntable, the scale factor difference is less than 1%. The accuracy and repeatability of the test system seems good.

  8. A Galvanic Coupling Method for Assessing Hydration Rates

    Directory of Open Access Journals (Sweden)

    Clement Ogugua Asogwa

    2016-07-01

    Full Text Available Recent advances in biomedical sensors, data acquisition techniques, microelectronics and wireless communication systems opened up the use of wearable technology for ehealth monitoring. We introduce a galvanic coupled intrabody communication for monitoring human body hydration. Studies in hydration provide the information necessary for understanding the desired fluid levels for optimal performance of the body’s physiological and metabolic processes during exercise and activities of daily living. Current measurement techniques are mostly suitable for laboratory purposes due to their complexity and technical requirements. Less technical methods such as urine color observation and skin turgor testing are subjective and cannot be integrated into a wearable device. Bioelectrical impedance methods are popular but mostly used for estimating total body water with limited accuracy and sensitive to 800 mL–1000 mL change in body fluid levels. We introduce a non-intrusive and simple method of tracking hydration rates that can detect up to 1.30 dB reduction in attenuation when as little as 100 mL of water is consumed. Our results show that galvanic coupled intrabody signal propagation can provide qualitative hydration and dehydration rates in line with changes in an individual’s urine specific gravity and body mass. The real-time changes in galvanic coupled intrabody signal attenuation can be integrated into wearable electronic devices to evaluate body fluid levels on a particular area of interest and can aid diagnosis and treatment of fluid disorders such as lymphoedema.

  9. Anisotropic surface hole-transport property of triphenylamine-derivative single crystal prepared by solution method

    Energy Technology Data Exchange (ETDEWEB)

    Umeda, Minoru, E-mail: mumeda@vos.nagaokaut.ac.jp [Nagaoka University of Technology, Kamitomioka, Nagaoka, Niigata 940-2188 (Japan); Katagiri, Mitsuhiko; Shironita, Sayoko [Nagaoka University of Technology, Kamitomioka, Nagaoka, Niigata 940-2188 (Japan); Nagayama, Norio [Nagaoka University of Technology, Kamitomioka, Nagaoka, Niigata 940-2188 (Japan); Ricoh Company, Ltd., Nishisawada, Numazu, Shizuoka 410-0007 (Japan)

    2016-12-01

    Highlights: • A hole transport molecule was investigated based on its electrochemical redox characteristics. • The solubility and supersolubility curves of the molecule were measured in order to prepare a large crystal. • The polarization micrograph and XRD results revealed that a single crystal was obtained. • An anisotropic surface conduction, in which the long-axis direction exceeds that of the amorphous layer, was observed. • The anisotropic surface conduction was well explained by the molecular stacked structure. - Abstract: This paper reports the anisotropic hole transport at the triphenylamine-derivative single crystal surface prepared by a solution method. Triphenylamine derivatives are commonly used in a hole-transport material for organic photoconductors of laser-beam printers, in which the materials are used as an amorphous form. For developing organic photovoltaics using the photoconductor’s technology, preparation of a single crystal seems to be a specific way by realizing the high mobility of an organic semiconductor. In this study, a single crystal of 4-(2,2-diphenylethenyl)-N,N-bis(4-methylphenyl)-benzenamine (TPA) was prepared and its anisotropic hole-transport property measured. First, the hole-transport property of the TPA was investigated based on its chemical structure and electrochemical redox characteristics. Next, a large-scale single crystal formation at a high rate was developed by employing a solution method based on its solubility and supersolubility curves. The grown TPA was found to be a single crystal based on the polarization micrograph observation and crystallographic analysis. For the TPA single crystal, an anisotropic surface conduction was found, which was well explained by its molecular stack structure. The measured current in the long-axis direction is one order of magnitude greater than that of amorphous TPA.

  10. Single-photon source engineering using a Modal Method

    DEFF Research Database (Denmark)

    Gregersen, Niels

    Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined as the num...... nanowire SPSs...

  11. Single molecule force spectroscopy: methods and applications in biology

    International Nuclear Information System (INIS)

    Shen Yi; Hu Jun

    2012-01-01

    Single molecule measurements have transformed our view of biomolecules. Owing to the ability of monitoring the activity of individual molecules, we now see them as uniquely structured, fluctuating molecules that stochastically transition between frequently many substrates, as two molecules do not follow precisely the same trajectory. Indeed, it is this discovery of critical yet short-lived substrates that were often missed in ensemble measurements that has perhaps contributed most to the better understanding of biomolecular functioning resulting from single molecule experiments. In this paper, we give a review on the three major techniques of single molecule force spectroscopy, and their applications especially in biology. The single molecular study of biotin-streptavidin interactions is introduced as a successful example. The problems and prospects of the single molecule force spectroscopy are discussed, too. (authors)

  12. Exploration of mechanisms underlying the strain-rate-dependent mechanical property of single chondrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Trung Dung; Gu, YuanTong, E-mail: yuantong.gu@qut.edu.au [School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Queensland (Australia)

    2014-05-05

    Based on the characterization by Atomic Force Microscopy, we report that the mechanical property of single chondrocytes has dependency on the strain-rates. By comparing the mechanical deformation responses and the Young's moduli of living and fixed chondrocytes at four different strain-rates, we explore the deformation mechanisms underlying this dependency property. We found that the strain-rate-dependent mechanical property of living cells is governed by both of the cellular cytoskeleton and the intracellular fluid when the fixed chondrocytes are mainly governed by their intracellular fluid, which is called the consolidation-dependent deformation behavior. Finally, we report that the porohyperelastic constitutive material model which can capture the consolidation-dependent behavior of both living and fixed chondrocytes is a potential candidature to study living cell biomechanics.

  13. Calculation method for gamma-dose rates from spherical puffs

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Deme, S.; Lang, E.

    1993-05-01

    The Lagrangian puff-models are widely used for calculation of the dispersion of atmospheric releases. Basic output from such models are concentrations of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on semi-infinite cloud model. This method is however only applicable for points far away from the release point. The exact calculation of the cloud dose using the volume integral requires significant computer time. The volume integral for the gamma dose could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor due to the fact that the same correction factors are used for all isotopes. The authors describe a more elaborate correction method. This method uses precalculated values of the gamma-dose rate as a function of the puff dispersion parameter (δ p ) and the distance from the puff centre for four energy groups. The release of energy for each radionuclide in each energy group has been calculated and tabulated. Based on these tables and a suitable interpolation procedure the calculation of gamma doses takes very short time and is almost independent of the number of radionuclides. (au) (7 tabs., 7 ills., 12 refs.)

  14. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  15. A forward error correction technique using a high-speed, high-rate single chip codec

    Science.gov (United States)

    Boyd, R. W.; Hartman, W. F.; Jones, Robert E.

    1989-01-01

    The authors describe an error-correction coding approach that allows operation in either burst or continuous modes at data rates of multiple hundreds of megabits per second. Bandspreading is low since the code rate is 7/8 or greater, which is consistent with high-rate link operation. The encoder, along with a hard-decision decoder, fits on a single application-specific integrated circuit (ASIC) chip. Soft-decision decoding is possible utilizing applique hardware in conjunction with the hard-decision decoder. Expected coding gain is a function of the application and is approximately 2.5 dB for hard-decision decoding at 10-5 bit-error rate with phase-shift-keying modulation and additive Gaussian white noise interference. The principal use envisioned for this technique is to achieve a modest amount of coding gain on high-data-rate, bandwidth-constrained channels. Data rates of up to 300 Mb/s can be accommodated by the codec chip. The major objective is burst-mode communications, where code words are composed of 32 n data bits followed by 32 overhead bits.

  16. Methods for estimating disease transmission rates: Evaluating the precision of Poisson regression and two novel methods

    DEFF Research Database (Denmark)

    Kirkeby, Carsten Thure; Hisham Beshara Halasa, Tariq; Gussmann, Maya Katrin

    2017-01-01

    Precise estimates of disease transmission rates are critical for epidemiological simulation models. Most often these rates must be estimated from longitudinal field data, which are costly and time-consuming to conduct. Consequently, measures to reduce cost like increased sampling intervals...... or subsampling of the population are implemented. To assess the impact of such measures we implement two different SIS models to simulate disease transmission: A simple closed population model and a realistic dairy herd including population dynamics. We analyze the accuracy of different methods for estimating...... the transmission rate. We use data from the two simulation models and vary the sampling intervals and the size of the population sampled. We devise two new methods to determine transmission rate, and compare these to the frequently used Poisson regression method in both epidemic and endemic situations. For most...

  17. New real-time heartbeat detection method using the angle of a single-lead electrocardiogram.

    Science.gov (United States)

    Song, Mi-Hye; Cho, Sung-Pil; Kim, Wonky; Lee, Kyoung-Joung

    2015-04-01

    This study presents a new real-time heartbeat detection algorithm using the geometric angle between two consecutive samples of single-lead electrocardiogram (ECG) signals. The angle was adopted as a new index representing the slope of ECG signal. The method consists of three steps: elimination of high-frequency noise, calculation of the angle of ECG signal, and detection of R-waves using a simple adaptive thresholding technique. The MIT-BIH arrhythmia database, QT database, European ST-T database, T-wave alternans database and synthesized ECG signals were used to evaluate the performance of the proposed algorithm and compare with the results of other methods suggested in literature. The proposed method shows a high detection rate-99.95% of the sensitivity, 99.95% of the positive predictivity, and 0.10% of the fail detection rate on the four databases. The result shows that the proposed method can yield better or comparable performance than other literature despite the relatively simple process. The proposed algorithm needs only a single-lead ECG, and involves a simple and quick calculation. Moreover, it does not require post-processing to enhance the detection. Thus, it can be effectively applied to various real-time healthcare and medical devices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A single-probe heat pulse method for estimating sap velocity in trees.

    Science.gov (United States)

    López-Bernal, Álvaro; Testi, Luca; Villalobos, Francisco J

    2017-10-01

    Available sap flow methods are still far from being simple, cheap and reliable enough to be used beyond very specific research purposes. This study presents and tests a new single-probe heat pulse (SPHP) method for monitoring sap velocity in trees using a single-probe sensor, rather than the multi-probe arrangements used up to now. Based on the fundamental conduction-convection principles of heat transport in sapwood, convective velocity (V h ) is estimated from the temperature increase in the heater after the application of a heat pulse (ΔT). The method was validated against measurements performed with the compensation heat pulse (CHP) technique in field trees of six different species. To do so, a dedicated three-probe sensor capable of simultaneously applying both methods was produced and used. Experimental measurements in the six species showed an excellent agreement between SPHP and CHP outputs for moderate to high flow rates, confirming the applicability of the method. In relation to other sap flow methods, SPHP presents several significant advantages: it requires low power inputs, it uses technically simpler and potentially cheaper instrumentation, the physical damage to the tree is minimal and artefacts caused by incorrect probe spacing and alignment are removed. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  19. Cumulative Success Rate of Short and Ultrashort Implants Supporting Single Crowns in the Posterior Maxilla: A 3-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    Giorgio Lombardo

    2017-01-01

    Full Text Available Aim. To determine cumulative success rate (CSR of short and ultrashort implants in the posterior maxilla restored with single crowns. Patients and Methods. We performed a retrospective study in 65 patients with 139 implants. 46 were ultrashort and 93 short. Implants were placed with a staged approach and restored with single crowns. Success rate, clinical and radiographic outcomes, and crown-to-implant ratio (CIR were assessed after three years. Statistical analysis was performed by descriptive and inferential statistics. A log-binomial regression model where the main outcome was implant success was achieved. Coefficients and 95% confidence intervals were reported. Analyses were performed with Stata 13.2 for Windows. Results. 61.54% of patients were female and mean overall age was 51.9±11.08 years old. Overall CSR was 97.1% (95% CI: 92.4–98.9: 97.9 and 95.1% for short and ultrashort, respectively (P value: 0.33. Four implants failed. Covariates were not associated with CSR (P value > 0.05. Regression model showed coefficients correlated with implant success for ultrashort implants (0.87 and most of covariates but none were statistically significant (P values > 0.05. Conclusions. Our results suggest that short and ultrashort implants may be successfully placed and restored with single crowns in the resorbed maxillary molar region.

  20. [A project to improve the validity rate for nursing staff operating single door autoclave sterilizers].

    Science.gov (United States)

    Chen, Chun-Hung; Li, Cheng-Chang; Chou, Chuan-Yu; Chen, Shu-Hwa

    2009-08-01

    This project was designed to improve the low validity rate for nurses responsible to operate single door autoclave sterilizers in the operating room. By investigating the current status, we found that the nursing staff validity rate of cognition on the autoclave sterilizer was 85%, and the practice operating check validity rate was only 80%. Such was due to a lack of in-service education. Problems with operation included: 1. Unsafe behaviors - not following standard procedure, lacking relevant operating knowledge and absence of a check form; 2. Unsafe environment - the conveying steam piping was typically not covered and lacked operation marks. Recommended improvement measures included: 1. holding in-service education; 2. generating an operation procedure flow chart; 3. implementing obstacle eliminating procedures; 4. covering piping to prevent fire and burns; 5. performing regular checks to ensure all procedures are followed. Following intervention, nursing staff cognition rose from 85% to 100%, while the operation validity rate rose from 80% to 100%. These changes ensure a safer operating room environment, and helps facilities move toward a zero accident rate in the healthcare environment.

  1. Dose rate reduction method for NMCA applied BWR plants

    International Nuclear Information System (INIS)

    Nagase, Makoto; Aizawa, Motohiro; Ito, Tsuyoshi; Hosokawa, Hideyuki; Varela, Juan; Caine, Thomas

    2012-09-01

    BRAC (BWR Radiation Assessment and Control) dose rate is used as an indicator of the incorporation of activated corrosion by products into BWR recirculation piping, which is known to be a significant contributor to dose rate received by workers during refueling outages. In order to reduce radiation exposure of the workers during the outage, it is desirable to keep BRAC dose rates as low as possible. After HWC was adopted to reduce IGSCC, a BRAC dose rate increase was observed in many plants. As a countermeasure to these rapid dose rate increases under HWC conditions, Zn injection was widely adopted in United States and Europe resulting in a reduction of BRAC dose rates. However, BRAC dose rates in several plants remain high, prompting the industry to continue to investigate methods to achieve further reductions. In recent years a large portion of the BWR fleet has adopted NMCA (NobleChem TM ) to enhance the hydrogen injection effect to suppress SCC. After NMCA, especially OLNC (On-Line NobleChem TM ), BRAC dose rates were observed to decrease. In some OLNC applied BWR plants this reduction was observed year after year to reach a new reduced equilibrium level. This dose rate reduction trends suggest the potential dose reduction might be obtained by the combination of Pt and Zn injection. So, laboratory experiments and in-plant tests were carried out to evaluate the effect of Pt and Zn on Co-60 deposition behaviour. Firstly, laboratory experiments were conducted to study the effect of noble metal deposition on Co deposition on stainless steel surfaces. Polished type 316 stainless steel coupons were prepared and some of them were OLNC treated in the test loop before the Co deposition test. Water chemistry conditions to simulate HWC were as follows: Dissolved oxygen, hydrogen and hydrogen peroxide were below 5 ppb, 100 ppb and 0 ppb (no addition), respectively. Zn was injected to target a concentration of 5 ppb. The test was conducted up to 1500 hours at 553 K. Test

  2. Extending the performance of single-degree-of-freedom rate integrating gyros in strapdown applications

    Science.gov (United States)

    Baker, G. N.

    This paper examines the constraints upon a typical manufacturer of gyros and strapdown systems. It describes that while being responsive to exchange and keeping abreast of 'state of the art' technology, there are many reasons why the manufacturer must satisfy the market using existing technology and production equipment. The Single-Degree-of-Freedom Rate Integrating Gyro is a well established product, yet is capable of achieving far higher performances than originally envisaged due to modelling and characterization within digital strapdown systems. The parameters involved are discussed, and a description given of the calibration process undertaken on a strapdown system being manufactured in a production environment in batch quantities.

  3. Validation method training: nurses' experiences and ratings of work climate.

    Science.gov (United States)

    Söderlund, Mona; Norberg, Astrid; Hansebo, Görel

    2014-03-01

    Training nursing staff in communication skills can impact on the quality of care for residents with dementia and contributes to nurses' job satisfaction. Changing attitudes and practices takes time and energy and can affect the entire nursing staff, not just the nurses directly involved in a training programme. Therefore, it seems important to study nurses' experiences of a training programme and any influence of the programme on work climate among the entire nursing staff. To explore nurses' experiences of a 1-year validation method training programme conducted in a nursing home for residents with dementia and to describe ratings of work climate before and after the programme. A mixed-methods approach. Twelve nurses participated in the training and were interviewed afterwards. These individual interviews were tape-recorded and transcribed, then analysed using qualitative content analysis. The Creative Climate Questionnaire was administered before (n = 53) and after (n = 56) the programme to the entire nursing staff in the participating nursing home wards and analysed with descriptive statistics. Analysis of the interviews resulted in four categories: being under extra strain, sharing experiences, improving confidence in care situations and feeling uncertain about continuing the validation method. The results of the questionnaire on work climate showed higher mean values in the assessment after the programme had ended. The training strengthened the participating nurses in caring for residents with dementia, but posed an extra strain on them. These nurses also described an extra strain on the entire nursing staff that was not reflected in the results from the questionnaire. The work climate at the nursing home wards might have made it easier to conduct this extensive training programme. Training in the validation method could develop nurses' communication skills and improve their handling of complex care situations. © 2013 Blackwell Publishing Ltd.

  4. Calculation method for gamma dose rates from Gaussian puffs

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.; Deme, S.; Lang, E.

    1995-06-01

    The Lagrangian puff models are widely used for calculation of the dispersion of releases to the atmosphere. Basic output from such models is concentration of material in the air and on the ground. The most simple method for calculation of the gamma dose from the concentration of airborne activity is based on the semi-infinite cloud model. This method is however only applicable for puffs with large dispersion parameters, i.e. for receptors far away from the release point. The exact calculation of the cloud dose using volume integral requires large computer time usually exceeding what is available for real time calculations. The volume integral for gamma doses could be approximated by using the semi-infinite cloud model combined with correction factors. This type of calculation procedure is very fast, but usually the accuracy is poor because only a few of the relevant parameters are considered. A multi-parameter method for calculation of gamma doses is described here. This method uses precalculated values of the gamma dose rates as a function of E γ , σ y , the asymmetry factor - σ y /σ z , the height of puff center - H and the distance from puff center R xy . To accelerate the calculations the release energy, for each significant radionuclide in each energy group, has been calculated and tabulated. Based on the precalculated values and suitable interpolation procedure the calculation of gamma doses needs only short computing time and it is almost independent of the number of radionuclides considered. (au) 2 tabs., 15 ills., 12 refs

  5. Method for thermal processing alumina-enriched spinel single crystals

    Science.gov (United States)

    Jantzen, Carol M.

    1995-01-01

    A process for age-hardening alumina-rich magnesium aluminum spinel to obtain the desired combination of characteristics of hardness, clarity, flexural strength and toughness comprises selection of the time-temperature pair for isothermal heating followed by quenching. The time-temperature pair is selected from the region wherein the precipitate groups have the characteristics sought. The single crystal spinel is isothermally heated and will, if heated long enough pass from its single phase through two pre-precipitates and two metastable precipitates to a stable secondary phase precipitate within the spinel matrix. Quenching is done slowly at first to avoid thermal shock, then rapidly.

  6. THE SINGLE MATCH APPROACH TO STRIKE RATE ADJUSTMENTS IN BATTING PERFORMANCE MEASURES IN CRICKET

    Directory of Open Access Journals (Sweden)

    Hermanus H. Lemmer

    2011-12-01

    Full Text Available Batting performance measures containing strike rate adjustments take into account the important fact that if two batsmen had scored the same number of runs in a match, the one with the better strike rate had performed best. But match conditions can influence the batting and bowling performances of cricket players. On a good pitch a batsman can get a good score at a high strike rate, but if the pitch was bad, a similar good score is normally accompanied by a much lower strike rate. The main objective of this study is to propose a method that can be used to make batsmen's scores comparable despite the fact that playing conditions might have been very different. The number of runs scored by a batsman is adjusted by comparing his strike rate with the overall strike rate of all the players in the specific match. These adjusted runs are then used in the most appropriate formula to calculate the average of the batsman. The method is illustrated by using the results of the Indian Premier League 2009 Twenty20 Series played during May and June 2009. The main conclusion is that the traditional average is not the most appropriate measure to compare batsmen's performances after conclusion of a short series.

  7. Radiation damage in single-particle cryo-electron microscopy: effects of dose and dose rate

    International Nuclear Information System (INIS)

    Karuppasamy, Manikandan; Karimi Nejadasl, Fatemeh; Vulovic, Milos; Koster, Abraham J.; Ravelli, Raimond B. G.

    2011-01-01

    The effects of dose and dose-rate were investigated for single-particle cryo-electron microscopy using stroboscopic data collection. A dose-rate effect was observed favoring lower flux densities. Radiation damage is an important resolution limiting factor both in macromolecular X-ray crystallography and cryo-electron microscopy. Systematic studies in macromolecular X-ray crystallography greatly benefited from the use of dose, expressed as energy deposited per mass unit, which is derived from parameters including incident flux, beam energy, beam size, sample composition and sample size. In here, the use of dose is reintroduced for electron microscopy, accounting for the electron energy, incident flux and measured sample thickness and composition. Knowledge of the amount of energy deposited allowed us to compare doses with experimental limits in macromolecular X-ray crystallography, to obtain an upper estimate of radical concentrations that build up in the vitreous sample, and to translate heat-transfer simulations carried out for macromolecular X-ray crystallography to cryo-electron microscopy. Stroboscopic exposure series of 50–250 images were collected for different incident flux densities and integration times from Lumbricus terrestris extracellular hemoglobin. The images within each series were computationally aligned and analyzed with similarity metrics such as Fourier ring correlation, Fourier ring phase residual and figure of merit. Prior to gas bubble formation, the images become linearly brighter with dose, at a rate of approximately 0.1% per 10 MGy. The gradual decomposition of a vitrified hemoglobin sample could be visualized at a series of doses up to 5500 MGy, by which dose the sample was sublimed. Comparison of equal-dose series collected with different incident flux densities showed a dose-rate effect favoring lower flux densities. Heat simulations predict that sample heating will only become an issue for very large dose rates (50 e − Å −2 s

  8. [Incidence rate of adverse reaction/event by Qingkailing injection: a Meta-analysis of single rate].

    Science.gov (United States)

    Ai, Chun-ling; Xie, Yan-ming; Li, Ming-quan; Wang, Lian-xin; Liao, Xing

    2015-12-01

    To systematically review the incidence rate of adverse drug reaction/event by Qingkailing injection. Such databases as the PubMed, EMbase, the Cochrane library, CNKI, VIP WanFang data and CBM were searched by computer from foundation to July 30, 2015. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and cross check data. Then, Meta-analysis was performed by using the R 3.2.0 software, subgroup sensitivity analysis was performed based on age, mode of medicine, observation time and research quality. Sixty-three studies involving 9,793 patients with Qingkailing injection were included, 367 cases of adverse reactions/events were reported in total. The incidence rate of adverse reaction in skin and mucosa group was 2% [95% CI (0.02; 0.03)]; the digestive system adverse reaction was 6% [95% CI(0.05; 0.07); the injection site adverse reaction was 4% [95% CI (0.02; 0.07)]. In the digestive system as the main types of adverse reactions/events, incidence of children and adults were 4.6% [0.021 1; 0.097 7] and 6.9% [0.053 5; 0.089 8], respectively. Adverse reactions to skin and mucous membrane damage as the main performance/event type, the observation time > 7 days and ≤ 7 days incidence of 3% [0.012 9; 0.068 3] and 1.9% [0.007 8; 0.046 1], respectively. Subgroup analysis showed that different types of adverse reactions, combination in the incidence of adverse reactions/events were higher than that of single drug, the difference was statistically significant (P reactions occur, and clinical rational drug use, such as combination, age and other fators, and the influence factors vary in different populations. Therefore, clinical doctors for children and the elderly use special care was required for a clear and open spirit injection, the implementation of individualized medication.

  9. Long-term effects and colectomy rates in ulcerative colitis patients treated with infliximab: A Danish single center experience

    DEFF Research Database (Denmark)

    Teisner, A.S.; Ainsworth, M.A.; Brynskov, J.

    2010-01-01

    was to provide further data on the long-term effect of IFX for acute, severe and chronic, refractory UC in unselected patients treated at a single center. Material and Methods. A retrospective analysis of all patients (n = 52) treated with IFX for UC before February 2009 was performed. The material comprised 19......) had sustained clinical response. Conclusion. IFX is of long-term benefit as rescue treatment in selected patients with acute, severe UC with about two-thirds of the patients avoiding colectomy. The beneficial effect on colectomy rate in chronic, refractory UC seems less convincing although......Objective. Infliximab (IFX) is a well-established treatment for both acute, severe ulcerative colitis (UC) and chronic, refractory UC. However, data on the long-term clinical outcome and colectomy rates after IFX treatment in a routine clinical setting are sparse. The aim of this study...

  10. Method: a single nucleotide polymorphism genotyping method for Wheat streak mosaic virus

    Science.gov (United States)

    2012-01-01

    Background The September 11, 2001 attacks on the World Trade Center and the Pentagon increased the concern about the potential for terrorist attacks on many vulnerable sectors of the US, including agriculture. The concentrated nature of crops, easily obtainable biological agents, and highly detrimental impacts make agroterrorism a potential threat. Although procedures for an effective criminal investigation and attribution following such an attack are available, important enhancements are still needed, one of which is the capability for fine discrimination among pathogen strains. The purpose of this study was to develop a molecular typing assay for use in a forensic investigation, using Wheat streak mosaic virus (WSMV) as a model plant virus. Method This genotyping technique utilizes single base primer extension to generate a genetic fingerprint. Fifteen single nucleotide polymorphisms (SNPs) within the coat protein and helper component-protease genes were selected as the genetic markers for this assay. Assay optimization and sensitivity testing was conducted using synthetic targets. WSMV strains and field isolates were collected from regions around the world and used to evaluate the assay for discrimination. The assay specificity was tested against a panel of near-neighbors consisting of genetic and environmental near-neighbors. Result Each WSMV strain or field isolate tested produced a unique SNP fingerprint, with the exception of three isolates collected within the same geographic location that produced indistinguishable fingerprints. The results were consistent among replicates, demonstrating the reproducibility of the assay. No SNP fingerprints were generated from organisms included in the near-neighbor panel, suggesting the assay is specific for WSMV. Using synthetic targets, a complete profile could be generated from as low as 7.15 fmoles of cDNA. Conclusion The molecular typing method presented is one tool that could be incorporated into the forensic

  11. An improved method for the molecular identification of single dinoflagellate cysts

    Directory of Open Access Journals (Sweden)

    Yangchun Gao

    2017-04-01

    Full Text Available Background Dinoflagellate cysts (i.e., dinocysts are biologically and ecologically important as they can help dinoflagellate species survive harsh environments, facilitate their dispersal and serve as seeds for harmful algal blooms. In addition, dinocysts derived from some species can produce more toxins than vegetative forms, largely affecting species through their food webs and even human health. Consequently, accurate identification of dinocysts represents the first crucial step in many ecological studies. As dinocysts have limited or even no available taxonomic keys, molecular methods have become the first priority for dinocyst identification. However, molecular identification of dinocysts, particularly when using single cells, poses technical challenges. The most serious is the low success rate of PCR, especially for heterotrophic species. Methods In this study, we aim to improve the success rate of single dinocyst identification for the chosen dinocyst species (Gonyaulax spinifera, Polykrikos kofoidii, Lingulodinium polyedrum, Pyrophacus steinii, Protoperidinium leonis and Protoperidinium oblongum distributed in the South China Sea. We worked on two major technical issues: cleaning possible PCR inhibitors attached on the cyst surface and designing new dinoflagellate-specific PCR primers to improve the success of PCR amplification. Results For the cleaning of single dinocysts separated from marine sediments, we used ultrasonic wave-based cleaning and optimized cleaning parameters. Our results showed that the optimized ultrasonic wave-based cleaning method largely improved the identification success rate and accuracy of both molecular and morphological identifications. For the molecular identification with the newly designed dinoflagellate-specific primers (18S634F-18S634R, the success ratio was as high as 86.7% for single dinocysts across multiple taxa when using the optimized ultrasonic wave-based cleaning method, and much higher than that

  12. Single-sheet identification method of heavy charged particles using ...

    Indian Academy of Sciences (India)

    of the single-sheet particle identification technique in CR-39 and CN-85 polycarbonate by plotting track cone length ... in neutron dosimetry, gamma and cosmic rays detection, heavy ion and nuclear physics and corpuscular ..... [13] R P Henke and E V Benton, Charged particle tracks in polymers: No. 5-A com- puter code for ...

  13. Effects of Single Film, Packaging Methods and Relative Humidity on ...

    African Journals Online (AJOL)

    This study was carried out to determine the effect of single film packaging and relative humidity (RH) on the moisture content and water activity of Kilishi during storage. Polypropylene (PP) and high-density polyethylene (HDPE) films were used for the packaging. Kilishi was prepared by trimming off blood vessels, fat and ...

  14. Load Rate Effects in Adhesive Single Lap Joints Bonded with Epoxy/Ceramic Composites

    Directory of Open Access Journals (Sweden)

    Heraldo da Costa Mattos

    Full Text Available Abstract The present paper is concerned with the analysis of the effect of the loading rate in a particular class of single lap joints used in the oil industry. The adhesive/adherend system consists of ASTM A36 steel plates bonded with an epoxy/ceramic composite. The loading rate sensitivity is analysed considering two different situations: (i strain controlled quasi-static rupture tests and (ii applications in which the joint may oscillate like a spring. This second situation is motivated by a specific application: the transport of an ethanol reservoir by a crane using a special truss lifting system attached to the tank through bonded joints. Quasi-static tensile tests allow observing a rate-dependent behaviour of the joint with higher strengths for higher cross-head velocities. An algebraic equation is proposed to predict the dependence of the rupture force on the elongation rate in tensile tests and the model predictions are in good agreement with experimental results. However, in the case of the transport of a tank with mass M (situation (ii, the lifting system cannot be only designed to resist the static load (the weight. Fast loading may induce vibration. Like in a spring-mass system, even a very small oscillation of the joint induces a dynamic load that is higher than the static load. A simple analysis allows proposing conditions for a safe operation in this case.

  15. High sensitivity fluorescent single particle and single molecule detection apparatus and method

    Science.gov (United States)

    Mathies, Richard A.; Peck, Konan; Stryer, Lubert

    1990-01-01

    Apparatus is described for ultrasensitive detection of single fluorescent particles down to the single fluorescent molecule limit in a fluid or on a substrate comprising means for illuminating a predetermined volume of the fluid or area of the substrate whereby to emit light including background light from the fluid and burst of photons from particles residing in the area. The photon burst is detected in real time to generate output representative signal. The signal is received and the burst of energy from the fluorescent particles is distinguished from the background energy to provide an indication of the number, location or concentration of the particles or molecules.

  16. The single match approach to strike rate adjustments in batting performance measures in cricket.

    Science.gov (United States)

    Lemmer, Hermanus H

    2011-01-01

    Batting performance measures containing strike rate adjustments take into account the important fact that if two batsmen had scored the same number of runs in a match, the one with the better strike rate had performed best. But match conditions can influence the batting and bowling performances of cricket players. On a good pitch a batsman can get a good score at a high strike rate, but if the pitch was bad, a similar good score is normally accompanied by a much lower strike rate. The main objective of this study is to propose a method that can be used to make batsmen's scores comparable despite the fact that playing conditions might have been very different. The number of runs scored by a batsman is adjusted by comparing his strike rate with the overall strike rate of all the players in the specific match. These adjusted runs are then used in the most appropriate formula to calculate the average of the batsman. The method is illustrated by using the results of the Indian Premier League 2009 Twenty20 Series played during May and June 2009. The main conclusion is that the traditional average is not the most appropriate measure to compare batsmen's performances after conclusion of a short series. Key pointsIt is unfair to compare the score of a batsman obtained on a good pitch under ideal batting conditions with that of a batsman who had to battle under severe conditions.By comparing a batsman's strike rate with the overall strike rate of the players in the specific match, his score can be adjusted to get a better figure for his true performance.The results demonstrate clearly that the use of adjusted scores lead to rankings that differ from those based on the traditional measures.

  17. 76 FR 38282 - Federal Employees Health Benefits Program: New Premium Rating Method for Most Community Rated Plans

    Science.gov (United States)

    2011-06-29

    ...-AM39 Federal Employees Health Benefits Program: New Premium Rating Method for Most Community Rated... final regulation to establish a new rate-setting procedure for most FEHB plans that are subject to... most community rated plans meet an FEHB-specific medical loss ratio (MLR) target. Plans that are...

  18. The different biological effects of single, fractioned and continuous low dose rate radiation on CL187 colorectal cancer cell line

    International Nuclear Information System (INIS)

    Wang Hao; Wang Junjie; Qu Ang; Li Jin'na; Liu Jingjia

    2012-01-01

    Objective: To investigate the effect and underlying mechanism of single, fractioned and continuous low dose rate radiation on CL187 colorectal cancer cell line. Methods: CL187 cells were exposed to 6 MV X-rays at a high dose rate of 4 Gy/min and 125 I seed at a low dose rate of 2.77 cGy/h with three groups:single dose radiation group (SDR), fractioned dose radiation group (FDR) by 2 Gy/f, and continuous low dose rate radiation group (CLDR). The radiation doses were 0, 2, 4 and 8 Gy. Total cell number and cell viability were determined by trypan blue. Clone forming assay was used to evaluate the cell proliferation ability. The percentage of apoptosis cells was analyzed by flow cytometry. Western blot was used to detect the protein expression levels of PHLPP2, PTEN and Bax. Results: Compared with SDR and FDR groups, the total cell number and survival fraction of CLDR group decreased. The relative biological effect (RBE) for 125 I seeds compared with 6 MV X-rays was 1.41. The percentage of apoptosis cells of CLDR group was significantly increased (t=-15.08, -11.99, P<0.05). The expression level of Bax increased in CLDR group, while no obvious changes were observed on PHLPP2 and PTEN among three groups. Conclusions: The expression level of PHLPP2 increases in SDR, FDR and CLDR group, while it seems that it was not influenced by dose rate. The expression level of Bax increased in three groups, while more colorectal CL187 cells in CLDR group may be killed due to the increase of Bax expression. (authors)

  19. The Choice Method of Selected Material has influence single evaporation flash method

    International Nuclear Information System (INIS)

    Sunaryo, Geni Rina; Sumijanto; Nurul L, Siti

    2000-01-01

    The final objective of this research is to design the mini scale of desalination installation. It has been started from 1997/1998 and has been doing for this 3 years. Where the study on the assessment of various desalination system has been done in the first year and thermodynamic in the second year. In this third year, literatully study on material resistance from outside pressure has been done. The number of pressure for single evaporator flashing method is mainly depend on the temperature that applied in that system. In this paper, the configuration stage, the choice method of selecting material for main evaporator vessel, tube, tube plates, water boxes, pipework, and valves for multistage flash distillation will be described. The choice of selecting material for MSF is base on economical consideration, cheap, high resistance and easy to be maintained

  20. An Asymmetrical Space Vector Method for Single Phase Induction Motor

    DEFF Research Database (Denmark)

    Cui, Yuanhai; Blaabjerg, Frede; Andersen, Gert Karmisholt

    2002-01-01

    the motor torque performance is not good enough. This paper addresses a new control method, an asymmetrical space vector method with PWM modulation, also a three-phase inverter is used for the main winding and the auxiliary winding. This method with PWM modulation is implemented to control the motor speed...

  1. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    easily implemented and is suitable for large data sets, like those in data mining appli- cations. Experimental results show that, with a small loss of quality, the proposed method can significantly reduce the time taken than the conventional kernel k-means cluster- ing method. The proposed method is also compared with other ...

  2. Development of a method for rating climate seat comfort

    Science.gov (United States)

    Scheffelmeier, M.; Classen, E.

    2017-10-01

    The comfort aspect in the vehicle interior is becoming increasingly important. A high comfort level offers the driver a good and secure feeling and has a strong influence on passive traffic safety. One important part of comfort is the climate aspect, especially the microclimate that emerges between passenger and seat. In this research, different combinations of typical seat materials are used. Fourteen woven and knitted fabrics and eight leathers and its substitutes for the face fabric layer, one foam, one non-woven and one 3D spacer for the plus pad layer and for the support layer three foam types with variations in structure and raw material as well as one rubber hair structure were investigated. To characterise this sample set by thermo-physiological aspects (e.g. water vapour resistance Ret, thermal resistance Rct, buffering capacity of water vapour Fd) regular and modified sweating guarded hotplates were used according to DIN EN ISO 11092. The results of the material characterisation confirm the common knowledge that seat covers out of textiles have better water vapour resistance values than leathers and its substitutes. Subject trials in a driving simulator were executed to rate the subjective sensation while driving in a vehicle seat. With a thermal, sweating Manikin (Newton Type, Thermetrics) objective product measurements were carried out on the same seat. Indeed the subject trials show that every test subject has his or her own subjective perception concerning the climate comfort. The results of the subject trials offered the parameters for the Newton measuring method. Respectively the sweating rate, sit-in procedure, ambient conditions and sensor positions on and between the seat layers must be comparable with the subject trials. By taking care of all these parameters it is possible to get repeatable and reliable results with the Newton Manikin. The subjective feelings of the test subjects, concerning the microclimate between seat and passenger, provide

  3. New library construction method for single-cell genomes.

    Directory of Open Access Journals (Sweden)

    Larry Xi

    Full Text Available A central challenge in sequencing single-cell genomes is the accurate determination of point mutations, phasing of these mutations, and identifying copy number variations with few assumptions. Ideally, this is accomplished under as low sequencing coverage as possible. Here we report our attempt to meet these goals with a novel library construction and library amplification methodology. In our approach, single-cell genomic DNA is first fragmented with saturated transposition to make a primary library that uniformly covers the whole genome by short fragments. The library is then amplified by a carefully optimized PCR protocol in a uniform and synchronized fashion for next-generation sequencing. Each step of the protocol can be quantitatively characterized. Our shallow sequencing data show that the library is tightly distributed and is useful for the determination of copy number variations.

  4. Comparison on genomic predictions using three GBLUP methods and two single-step blending methods in the Nordic Holstein population

    Directory of Open Access Journals (Sweden)

    Gao Hongding

    2012-07-01

    Full Text Available Abstract Background A single-step blending approach allows genomic prediction using information of genotyped and non-genotyped animals simultaneously. However, the combined relationship matrix in a single-step method may need to be adjusted because marker-based and pedigree-based relationship matrices may not be on the same scale. The same may apply when a GBLUP model includes both genomic breeding values and residual polygenic effects. The objective of this study was to compare single-step blending methods and GBLUP methods with and without adjustment of the genomic relationship matrix for genomic prediction of 16 traits in the Nordic Holstein population. Methods The data consisted of de-regressed proofs (DRP for 5 214 genotyped and 9 374 non-genotyped bulls. The bulls were divided into a training and a validation population by birth date, October 1, 2001. Five approaches for genomic prediction were used: 1 a simple GBLUP method, 2 a GBLUP method with a polygenic effect, 3 an adjusted GBLUP method with a polygenic effect, 4 a single-step blending method, and 5 an adjusted single-step blending method. In the adjusted GBLUP and single-step methods, the genomic relationship matrix was adjusted for the difference of scale between the genomic and the pedigree relationship matrices. A set of weights on the pedigree relationship matrix (ranging from 0.05 to 0.40 was used to build the combined relationship matrix in the single-step blending method and the GBLUP method with a polygenetic effect. Results Averaged over the 16 traits, reliabilities of genomic breeding values predicted using the GBLUP method with a polygenic effect (relative weight of 0.20 were 0.3% higher than reliabilities from the simple GBLUP method (without a polygenic effect. The adjusted single-step blending and original single-step blending methods (relative weight of 0.20 had average reliabilities that were 2.1% and 1.8% higher than the simple GBLUP method, respectively. In

  5. FY2016 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

    Energy Technology Data Exchange (ETDEWEB)

    Neeway, James J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Asmussen, Robert M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Parruzot, Benjamin PG [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Cordova, Elsa [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Leavy, Ian I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stephenson, John R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McElroy, Erin M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-21

    The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various chemical conditions. To accomplish this, an IDF PA model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon concentrations in solution, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the alkali-ion exchange process as sodium is leached from the glass and into solution. The effect of temperature, pH, H4SiO4 activity, and the rate of ion-exchange can be parameterized and implemented directly into the PA rate law model. The rate law parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. To date, rate law parameters have been determined for seven ILAW glass compositions, thus additional rate law parameters on a wider range of compositions will supplement the existing body of data for PA maintenance activities. The data provided in this report can be used by ILAW glass scientists to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate law parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

  6. Comparison of variations detection between whole-genome amplification methods used in single-cell resequencing

    DEFF Research Database (Denmark)

    Hou, Yong; Wu, Kui; Shi, Xulian

    2015-01-01

    BACKGROUND: Single-cell resequencing (SCRS) provides many biomedical advances in variations detection at the single-cell level, but it currently relies on whole genome amplification (WGA). Three methods are commonly used for WGA: multiple displacement amplification (MDA), degenerate-oligonucleoti......BACKGROUND: Single-cell resequencing (SCRS) provides many biomedical advances in variations detection at the single-cell level, but it currently relies on whole genome amplification (WGA). Three methods are commonly used for WGA: multiple displacement amplification (MDA), degenerate...

  7. Variation in Primary Cesarean Delivery Rates by Individual Physician within a Single Hospital Laborist Model

    Science.gov (United States)

    METZ, Torri D.; ALLSHOUSE, Amanda A.; GILBERT, Sara A Babcock; DOYLE, Reina; TONG, Angie; CAREY, J. Christopher

    2016-01-01

    Background Laborist practice models are associated with lower cesarean delivery rates than individual private practice models in several studies; however, this effect is not uniform. Further exploration of laborist models may help us better understand the observed reduction in cesarean delivery rates in some hospitals with implementation of a laborist model. Objective Our objective was to evaluate the degree of variation in primary cesarean delivery rates by individual laborists within a single institution employing a laborist model. In addition, we sought to evaluate whether differences in cesarean delivery rates resulted in different maternal or short-term neonatal outcomes. Study Design At this teaching institution, one laborist (either a generalist or maternal-fetal medicine attending physician) is directly responsible for labor and delivery management during each shift. No patients are followed in a private practice model nor are physicians incentivized to perform deliveries. We retrospectively identified all laborists who delivered nulliparous, term women with cephalic singletons at this institution from 2007-14. Overall and individual primary cesarean delivery rates were reported as percentages with exact Pearson 95% CI. Laborists were grouped by tertile as having low, medium or high cesarean delivery rates. Characteristics of the women delivered, indications for cesarean delivery, and short-term neonatal outcomes were compared between these groups. A binomial regression model of cesarean delivery was estimated, where the relative rates of each laborist compared to the lowest-unadjusted laborist rate were calculated; a second model was estimated to adjust for patient-level maternal characteristics. Results Twenty laborists delivered 2,224 nulliparous, term women with cephalic singletons. The overall cesarean delivery rate was 24.1% (95% CI 21.4-26.8). In an unadjusted binomial model, the overall effect of individual laborist was significant (pcesarean

  8. Development of nondestructive screening methods for single kernel characterization of wheat

    DEFF Research Database (Denmark)

    Nielsen, J.P.; Pedersen, D.K.; Munck, L.

    2003-01-01

    The development of nondestructive screening methods for single seed protein, vitreousness, density, and hardness index has been studied for single kernels of European wheat. A single kernel procedure was applied involving, image analysis, near-infrared transmittance (NIT) spectroscopy, laboratory...... predictability. However, by applying an averaging approach, in which single seed replicate measurements are mathematically simulated, a very good NIT prediction model was achieved. This suggests that the single seed NIT spectra contain hardness information, but that a single seed hardness method with higher...

  9. COMPARISON OF ALTERNATIVE METHODS OF PROJECTING THE POVERTY RATE.

    Science.gov (United States)

    The aim of the research is to determine whether recent high unemployment rates for youths , the aged, or minorities have been due to structural...changes in the US economy or to high general unemployment rates. The focus of this paper is on groups classified by age, sex, and race. For each group...regression analysis was used to estimate the effect of a linear time trend and the overall unemployment rate on the unemployment rate for a specific

  10. Pregnancy rates after artificial insemination with cooled stallion spermatozoa either with or without single layer centrifugation.

    Science.gov (United States)

    Morrell, J M; Richter, J; Martinsson, G; Stuhtmann, G; Hoogewijs, M; Roels, K; Dalin, A-M

    2014-11-01

    A successful outcome after artificial insemination with cooled semen is dependent on many factors, the sperm quality of the ejaculate being one. Previous studies have shown that spermatozoa with good motility, normal morphology, and good chromatin integrity can be selected by means of colloid centrifugation, particularly single layer centrifugation (SLC) using species-specific colloids. The purpose of the present study was to conduct an insemination trial with spermatozoa from "normal" ejaculates, i.e., from stallions with no known fertility problem, to determine whether the improvements in sperm quality seen in SLC-selected sperm samples compared with uncentrifuged controls in laboratory tests are reflected in an increased pregnancy rate after artificial insemination. In a multicentre study, SLC-selected sperm samples and uncentrifuged controls from eight stallions were inseminated into approximately 10 mares per treatment per stallion. Ultrasound examination was carried out approximately 16 days after insemination to detect an embryonic vesicle. The pregnancy rates per cycle were 45% for controls and 69% for SLC-selected sperm samples, which is statistically significant (P < 0.0018). Thus, the improvement in sperm quality reported previously for SLC-selected sperm samples is associated with an increase in pregnancy rate, even for ejaculates from stallions with no known fertility problem. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Distance dependence of the energy transfer rate from a single semiconductor nanostructure to graphene.

    Science.gov (United States)

    Federspiel, François; Froehlicher, Guillaume; Nasilowski, Michel; Pedetti, Silvia; Mahmood, Ather; Doudin, Bernard; Park, Serin; Lee, Jeong-O; Halley, David; Dubertret, Benoît; Gilliot, Pierre; Berciaud, Stéphane

    2015-02-11

    The near-field Coulomb interaction between a nanoemitter and a graphene monolayer results in strong Förster-type resonant energy transfer and subsequent fluorescence quenching. Here, we investigate the distance dependence of the energy transfer rate from individual, (i) zero-dimensional CdSe/CdS nanocrystals and (ii) two-dimensional CdSe/CdS/ZnS nanoplatelets to a graphene monolayer. For increasing distances d, the energy transfer rate from individual nanocrystals to graphene decays as 1/d(4). In contrast, the distance dependence of the energy transfer rate from a two-dimensional nanoplatelet to graphene deviates from a simple power law but is well described by a theoretical model, which considers a thermal distribution of free excitons in a two-dimensional quantum well. Our results show that accurate distance measurements can be performed at the single particle level using graphene-based molecular rulers and that energy transfer allows probing dimensionality effects at the nanoscale.

  12. Single Machine Problem with Multi-Rate-Modifying Activities under a Time-Dependent Deterioration

    Directory of Open Access Journals (Sweden)

    M. Huang

    2013-01-01

    Full Text Available The single machine scheduling problem with multi-rate-modifying activities under a time-dependent deterioration to minimize makespan is studied. After examining the characteristics of the problem, a number of properties and a lower bound are proposed. A branch and bound algorithm and a heuristic algorithm are used in the solution, and two special cases are also examined. The computational experiments show that, for the situation with a rate-modifying activity, the proposed branch and bound algorithm can solve situations with 50 jobs within a reasonable time, and the heuristic algorithm can obtain the near-optimal solution with an error percentage less than 0.053 in a very short time. In situations with multi-rate-modifying activities, the proposed branch and bound algorithm can solve the case with 15 jobs within a reasonable time, and the heuristic algorithm can obtain the near-optimal with an error percentage less than 0.070 in a very short time. The branch and bound algorithm and the heuristic algorithm are both shown to be efficient and effective.

  13. System and method for single-phase, single-stage grid-interactive inverter

    Science.gov (United States)

    Liu, Liming; Li, Hui

    2015-09-01

    The present invention provides for the integration of distributed renewable energy sources/storages utilizing a cascaded DC-AC inverter, thereby eliminating the need for a DC-DC converter. The ability to segment the energy sources and energy storages improves the maintenance capability and system reliability of the distributed generation system, as well as achieve wide range reactive power compensation. In the absence of a DC-DC converter, single stage energy conversion can be achieved to enhance energy conversion efficiency.

  14. Methods of achieving and maintaining an appropriate caesarean section rate.

    LENUS (Irish Health Repository)

    Robson, Michael

    2013-04-01

    Caesarean section rates continue to increase worldwide. The appropriate caesarean section rate remains a topic of debate among women and professionals. Evidence-based medicine has not provided an answer and depends on interpretation of the literature. Overall caesarean section rates are unhelpful, and caesarean section rates should not be judged in isolation from other outcomes and epidemiological characteristics. Better understanding of caesarean section rates, their consequences and their benefits will improve care, and enable learning between delivery units nationally and internationally. To achieve and maintain an appropriate caesarean section rate requires a Multidisciplinary Quality Assurance Programme in each delivery unit, recognising caesarean section rates as one of many factors that determine quality. Women will always choose the type of delivery that seems safest to them and their babies. Professionals need to monitor the quality of their practice continuously in a standardised way to ensure that women can make the right choice.

  15. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    In unsupervised classification, kernel -means clustering method has been shown to perform better than conventional -means clustering method in ... 518501, India; Department of Computer Science and Engineering, Jawaharlal Nehru Technological University, Anantapur College of Engineering, Anantapur 515002, India ...

  16. Single pass kernel k-means clustering method

    Indian Academy of Sciences (India)

    This approach has reduced both time complexity and memory requirements. However, the clustering result of this method will be very much deviated form that obtained using the conventional kernel k-means method. This is because of the fact that pseudo cluster centers in the input space may not represent the exact cluster ...

  17. Anti-dynamic-crosstalk method for single photon LIDAR detection

    Science.gov (United States)

    Zhang, Fan; Liu, Qiang; Gong, Mali; Fu, Xing

    2017-11-01

    With increasing number of vehicles equipped with light detection and ranging (LIDAR), crosstalk is identified as a critical and urgent issue in the range detection for active collision avoidance. Chaotic pulse position modulation (CPPM) applied in the transmitting pulse train has been shown to prevent crosstalk as well as range ambiguity. However, static and unified strategy on discrimination threshold and the number of accumulated pulse is not valid against crosstalk with varying number of sources and varying intensity of each source. This paper presents an adaptive algorithm to distinguish the target echo from crosstalk with dynamic and unknown level of intensity in the context of intelligent vehicles. New strategy is given based on receiver operating characteristics (ROC) curves that consider the detection requirements of the probability of detection and false alarm for the scenario with varying crosstalk. In the adaptive algorithm, the detected results are compared by the new strategy with both the number of accumulated pulses and the threshold being raised step by step, so that the target echo can be exactly identified from crosstalk with the dynamic and unknown level of intensity. The validity of the algorithm has been verified through the experiments with a single photon detector and the time correlated single photo counting (TCSPC) technique, demonstrating a marked drop in required shots for identifying the target compared with static and unified strategy

  18. Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate : A phantom study

    NARCIS (Netherlands)

    Dikkers, R.; Greuter, M. J. W.; Kristanto, W.; van Ooijen, P. M. A.; Sijens, P. E.; Willems, T. P.; Oudkerk, M.

    Purpose: To assess the influence of temporal resolution on image quality of computed tomographic (CT) coronary angiography by comparing 64-row Dual Source CT (DSCT) and Single Source CT (SSCT) at different heart rates. Methods: An anthropomorphic moving heart phantom was scanned at rest, and at 50

  19. Blood pressure and heart rate effects following a single dose of bitter orange.

    Science.gov (United States)

    Bui, Linda T; Nguyen, DiemThuy T; Ambrose, Peter J

    2006-01-01

    The ingredients of numerous "ephedra-free" dietary supplements used for weight loss include bitter orange, which contains sympathomimetic alkaloids such as synephrine. Due to the similarity in chemical structure to ephedrine and the potential sympathomimetic effects of synephrine, it is hypothesized that bitter orange may increase blood pressure (BP) and heart rate (HR). To determine the effects on BP and HR after a single dose of bitter orange in healthy adults. In a prospective, randomized, double-blind, placebo-controlled, crossover study, 15 young, healthy, adult subjects received either a single dose of Nature's Way Bitter Orange--a 900 mg dietary supplement extract standardized to 6% synephrine--or matching placebo, with a one week washout period. Systolic BP (SBP), diastolic BP (DBP), and HR were measured at baseline and every hour for 6 hours after administration. SBP after bitter orange was significantly increased versus placebo at hours 1-5 (p bitter orange, DBP after bitter orange was significantly increased versus placebo at hours 4 and 5 (p bitter orange versus placebo for hours 2-5 (p bitter orange versus placebo in young, healthy adults.

  20. Double-bootstrap methods that use a single double-bootstrap simulation

    OpenAIRE

    Chang, Jinyuan; Hall, Peter

    2014-01-01

    We show that, when the double bootstrap is used to improve performance of bootstrap methods for bias correction, techniques based on using a single double-bootstrap sample for each single-bootstrap sample can be particularly effective. In particular, they produce third-order accuracy for much less computational expense than is required by conventional double-bootstrap methods. However, this improved level of performance is not available for the single double-bootstrap methods that have been s...

  1. New Systematic CFD Methods to Calculate Static and Single Dynamic Stability Derivatives of Aircraft

    Directory of Open Access Journals (Sweden)

    Bai-gang Mi

    2017-01-01

    Full Text Available Several new systematic methods for high fidelity and reliability calculation of static and single dynamic derivatives are proposed in this paper. Angle of attack step response is used to obtain static derivative directly; then translation acceleration dynamic derivative and rotary dynamic derivative can be calculated by employing the step response motion of rate of the angle of attack and unsteady motion of pitching angular velocity step response, respectively. Longitudinal stability derivative calculations of SACCON UCAV are taken as test cases for validation. Numerical results of all cases achieve good agreement with reference values or experiments data from wind tunnel, which indicate that the proposed methods can be considered as new tools in the process of design and production of advanced aircrafts for their high efficiency and precision.

  2. Experiences with leak rate calculations methods for LBB application

    International Nuclear Information System (INIS)

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G.

    1997-01-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations

  3. Experiences with leak rate calculations methods for LBB application

    Energy Technology Data Exchange (ETDEWEB)

    Grebner, H.; Kastner, W.; Hoefler, A.; Maussner, G. [and others

    1997-04-01

    In this paper, three leak rate computer programs for the application of leak before break analysis are described and compared. The programs are compared to each other and to results of an HDR Reactor experiment and two real crack cases. The programs analyzed are PIPELEAK, FLORA, and PICEP. Generally, the different leak rate models are in agreement. To obtain reasonable agreement between measured and calculated leak rates, it was necessary to also use data from detailed crack investigations.

  4. Error baseline rates of five sample preparation methods used to characterize RNA virus populations.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Kugelman

    Full Text Available Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic "no amplification" method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a "targeted" amplification method, sequence-independent single-primer amplification (SISPA as a "random" amplification method, rolling circle reverse transcription sequencing (CirSeq as an advanced "no amplification" method, and Illumina TruSeq RNA Access as a "targeted" enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4-5 of all compared methods.

  5. Single Station System and Method of Locating Lightning Strikes

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Starr, Stanley O. (Inventor)

    2003-01-01

    An embodiment of the present invention uses a single detection system to approximate a location of lightning strikes. This system is triggered by a broadband RF detector and measures a time until the arrival of a leading edge of the thunder acoustic pulse. This time difference is used to determine a slant range R from the detector to the closest approach of the lightning. The azimuth and elevation are determined by an array of acoustic sensors. The leading edge of the thunder waveform is cross-correlated between the various acoustic sensors in the array to determine the difference in time of arrival, AT. A set of AT S is used to determine the direction of arrival, AZ and EL. The three estimated variables (R, AZ, EL) are used to locate a probable point of the lightning strike.

  6. Reliability of a 99sp(m)Tc-DTPA gamma camera technique for determination of single kidney glomerular filtration rate

    International Nuclear Information System (INIS)

    Rehling, M.; Moeller, M.L.; Thamdrup, B.; Lund, J.O.; Trap-Jensen, J.

    1986-01-01

    In a recent paper we described a method for calculation of single kidney glomerular filtration rate (SKGFR) from the 99 sp(m)Tc-DTPA renogram obtained by gamma camera. In this paper the reliability of the method was compared to other methods for estimation of GFR in 20 unilaterally nephrectomized patients. The values for SKGFR obtained from the renograms and from the estimated endogenous creatinine clearances according to serum creatinine concentration and a nomogram were both accurate. The reliability of the renography method was significantly better judged by less variance in the estimates. SKGFR calculated from the plasma clearance of 51 Cr-EDTA overestimated the renal clearance of inulin on an average by 11.3%. No difference was found in the variance of the values obtained from the renograms and from the plasma clearances of 51 Cr-EDTA compared to the renal clearance of inulin. Apart from the inaccuracy in the GFR values calculated from the plasma clearance of 51 Cr-EDTA, the reliability of these two methods was equal. (author)

  7. Flow rate calibration II: a clinical evaluation study using PanLeucoGating as a single-platform protocol.

    Science.gov (United States)

    Storie, Ian; Sawle, Alex; Whitby, Liam; Goodfellow, Karen; Granger, Vivian; Reilly, John T; Barnett, David

    2003-09-01

    CD4(+) T-lymphocyte enumeration is vital for monitoring disease progression in individuals positive for the human immunodeficiency virus (HIV), and as a result, there is a need to develop cost-effective protocols that provide accuracy, precision, and affordability. Recently, PanLeucoGating has been shown to fulfill these requirements; however, although comparable to state-of-the-art single-platform protocols (SP), there is still a requirement for an accurate total white cell count. To overcome this limitation, we recently developed a flow-rate based calibration method that enables the PanLeucoGating protocol to be used as a SP approach, and in this study show that this approach can be used for CD4(+) T-lymphocyte enumeration. A total of 113 HIV samples were analyzed using three protocols: (a) state-of-the art SP bead-based method (MultiSet; predicate protocol), (b) PanLeucoGating protocol used as a dual-platform (DP) approach, and (c) the newly developed flow rate-based SP approach. We demonstrate that flow rate calibration can be achieved easily and that the method is highly comparable to the state-of-the-art SP method. A high correlation was observed between the predicate protocol and the SP PanLeucoGating approach over the whole range of CD4 counts tested (r(2) = 0.9928; bias 8 cells/microl), including the clinically relevant range (e.g., 0-200 CD4 cells/microl; bias 0 cells/microl). For batched samples, the cost of providing a CD4(+) T-lymphocyte count was reduced to approximately US $1. The SP PanLeucoGating is a cost-effective approach to CD4(+) T-lymphocyte enumeration that maintains accuracy and precision. Copyright 2003 Wiley-Liss, Inc.

  8. Large pyramid shaped single crystals of BiFeO{sub 3} by solvothermal synthesis method

    Energy Technology Data Exchange (ETDEWEB)

    Sornadurai, D.; Ravindran, T. R.; Paul, V. Thomas; Sastry, V. Sankara [Condensed Matter Physics Division, Materials Science Group, Physical Metallurgy Division, Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamil Nadu (India); Condensed Matter Physics Division, Materials Science Group (India)

    2012-06-05

    Synthesis parameters are optimized in order to grow single crystals of multiferroic BiFeO{sub 3}. 2 to 3 mm size pyramid (tetrahedron) shaped single crystals were successfully obtained by solvothermal method. Scanning electron microscopy with EDAX confirmed the phase formation. Raman scattering spectra of bulk BiFeO3 single crystals have been measured which match well with reported spectra.

  9. Success rate of two different methods of ilioinguinal-iliohypogastric ...

    African Journals Online (AJOL)

    Background: The ilioinguinal-iliohypogastric (ILIH) nerve block is a safe, effective, and easy to perform in order to provide analgesia for a variety of inguinal surgical procedures in pediatric patients. A relatively high failure rate of 10%-25% has been reported, even in experienced hands. It is assumed that this high failure rate ...

  10. Effect of weed management methods and nitrogen fertilizer rates on ...

    African Journals Online (AJOL)

    Inefficient weed management practices and the use of inappropriate nitrogen fertilizer rates are the major causes of low yield of wheat in Ethiopia. Therefore, field experiments were conducted at Bobicho and Faate in southern Ethiopia to determine the effect of weed management practices and N fertilizer rates on grain yield ...

  11. Assessment of high-rate GPS using a single-axis shake table

    Science.gov (United States)

    Häberling, S.; Rothacher, M.; Geiger, A.

    2012-04-01

    The latest generation of GPS receivers is capable of tracking at 100 Hz potentially capturing high-frequency signals. The new possibility to measure highly dynamic motions could enlarge the applicability in navigation and Earth monitoring such as seismology. In this study, we assess the potential of high-rate GPS with a sampling rate up to 100 Hz for a large spectrum of different motions. These motions are generated on a single-axis shake table carrying a GPS antenna. The real motion of the shake table is additionally monitored by highly accurate inductive sensors recording at 2400 Hz which deliver the ground-truth for the GPS assessment. In order to identify and quantify the internal GPS receiver errors as well as the external error sources, test experiments are carried out with zero-baselines, very short and long baselines. Our experiment setup allows a detailed study of the dynamic behaviour of the GPS receiver signal tracking for different accelerations. The investigations are focusing on the impact of different tracking loop parameters for L1 and L2 on the GPS results. In order to minimize the receiver errors during highly dynamic motions, an optimal set of tracking loop parameters and a good understanding of the receiver transfer function are crucial. The characteristics of the results are also compared with tests carried out in static mode and using different receiver types.

  12. Sublimation rates of explosive materials : method development and initial results.

    Energy Technology Data Exchange (ETDEWEB)

    Phelan, James M.; Patton, Robert Thomas

    2004-08-01

    Vapor detection of explosives continues to be a technological basis for security applications. This study began experimental work to measure the chemical emanation rates of pure explosive materials as a basis for determining emanation rates of security threats containing explosives. Sublimation rates for TNT were determined with thermo gravimetric analysis using two different techniques. Data were compared with other literature values to provide sublimation rates from 25 to 70 C. The enthalpy of sublimation for the combined data was found to be 115 kJ/mol, which corresponds well with previously reported data from vapor pressure determinations. A simple Gaussian atmospheric dispersion model was used to estimate downrange concentrations based on continuous, steady-state conditions at 20, 45 and 62 C for a nominal exposed block of TNT under low wind conditions. Recommendations are made for extension of the experimental vapor emanation rate determinations and development of turbulent flow computational fluid dynamics based atmospheric dispersion estimates of standoff vapor concentrations.

  13. 76 FR 36857 - Federal Employees Health Benefits Program: New Premium Rating Method for Most Community Rated Plans

    Science.gov (United States)

    2011-06-23

    ... contains regulatory documents #0;having general applicability and legal effect, most of which are keyed #0... Federal Employees Health Benefits Program: New Premium Rating Method for Most Community Rated Plans AGENCY... final regulation to establish a new rate-setting procedure for most FEHB plans that are subject to...

  14. Government Should Subsidize, Not Tax, Marriage: Social Policies Have Influenced the Rate of Growth in Single-Parent Families

    Science.gov (United States)

    Peterson, Paul E.

    2015-01-01

    Based upon reflections from the Moynihan report of 1965, this author notes that the root causes of the growth in single-parent families have yet to be well identified, making it difficult to figure out where to go next. However, from 1965 onward, social policies have influenced the rate of growth in single-parent families. What is needed is a…

  15. Quantitative Single-letter Sequencing: a method for simultaneously monitoring numerous known allelic variants in single DNA samples

    Directory of Open Access Journals (Sweden)

    Duborjal Hervé

    2008-02-01

    Full Text Available Abstract Background Pathogens such as fungi, bacteria and especially viruses, are highly variable even within an individual host, intensifying the difficulty of distinguishing and accurately quantifying numerous allelic variants co-existing in a single nucleic acid sample. The majority of currently available techniques are based on real-time PCR or primer extension and often require multiplexing adjustments that impose a practical limitation of the number of alleles that can be monitored simultaneously at a single locus. Results Here, we describe a novel method that allows the simultaneous quantification of numerous allelic variants in a single reaction tube and without multiplexing. Quantitative Single-letter Sequencing (QSS begins with a single PCR amplification step using a pair of primers flanking the polymorphic region of interest. Next, PCR products are submitted to single-letter sequencing with a fluorescently-labelled primer located upstream of the polymorphic region. The resulting monochromatic electropherogram shows numerous specific diagnostic peaks, attributable to specific variants, signifying their presence/absence in the DNA sample. Moreover, peak fluorescence can be quantified and used to estimate the frequency of the corresponding variant in the DNA population. Using engineered allelic markers in the genome of Cauliflower mosaic virus, we reliably monitored six different viral genotypes in DNA extracted from infected plants. Evaluation of the intrinsic variance of this method, as applied to both artificial plasmid DNA mixes and viral genome populations, demonstrates that QSS is a robust and reliable method of detection and quantification for variants with a relative frequency of between 0.05 and 1. Conclusion This simple method is easily transferable to many other biological systems and questions, including those involving high throughput analysis, and can be performed in any laboratory since it does not require specialized

  16. A Method for Turbocharging Four-Stroke Single Cylinder Engines

    Science.gov (United States)

    Buchman, Michael; Winter, Amos

    2014-11-01

    Turbocharging is not conventionally used with single cylinder engines due to the timing mismatch between when the turbo is powered and when it can deliver air to the cylinder. The proposed solution involves a fixed, pressurized volume - which we call an air capacitor - on the intake side of the engine between the turbocharger and intake valves. The capacitor acts as a buffer and would be implemented as a new style of intake manifold with a larger volume than traditional systems. This talk will present the flow analysis used to determine the optimal size for the capacitor, which was found to be four to five times the engine capacity, as well as its anticipated contributions to engine performance. For a capacitor sized for a one-liter engine, the time to reach operating pressure was found to be approximately two seconds, which would be acceptable for slowly accelerating applications and steady state applications. The air density increase that could be achieved, compared to ambient air, was found to vary between fifty percent for adiabatic compression and no heat transfer from the capacitor, to eighty percent for perfect heat transfer. These increases in density are proportional to, to first order, the anticipated power increases that could be realized. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship under Grant No. 1122374.

  17. Polymorphic transitions in single crystals: A new molecular dynamics method

    Energy Technology Data Exchange (ETDEWEB)

    Parrinello, M.; Rahman, A.

    1981-12-01

    A new Lagrangian formulation is introduced. It can be used to make molecular dynamics (MD) calculations on systems under the most general, externally applied, conditions of stress. In this formulation the MD cell shape and size can change according to dynamical equations given by this Lagrangian. This new MD technique is well suited to the study of structural transformations in solids under external stress and at finite temperature. As an example of the use of this technique we show how a single crystal of Ni behaves under uniform uniaxial compressive and tensile loads. This work confirms some of the results of static (i.e., zero temperature) calculations reported in the literature. We also show that some results regarding the stress-strain relation obtained by static calculations are invalid at finite temperature. We find that, under compressive loading, our model of Ni shows a bifurcation in its stress-strain relation; this bifurcation provides a link in configuration space between cubic and hexagonal close packing. It is suggested that such a transformation could perhaps be observed experimentally under extreme conditions of shock.

  18. Power decoupling method for single phase differential buck converter

    DEFF Research Database (Denmark)

    Yao, Wenli; Tang, Yi; Zhang, Xiaobin

    2015-01-01

    inverter to improve the dc link power quality, and an improved active power decoupling method is proposed to achieve ripple power reduction for both AC-DC and DC-AC conversions. The ripple energy storage is realized by the filter capacitors, which are connected between the output terminal and the negative...... generation technique is proposed to provide accurate ripple power compensation, and closed-loop controllers are also designed based on small signal models. The effectiveness of this power decoupling method is verified by detailed simulation studies as well as laboratory prototype experimental results....... dc bus. By properly controlling the differential mode voltage of the capacitors, it is possible to transfer desired energy between the DC port and AC port. The common mode voltage is controlled in such a way that the ripple power on the dc side will be reduced. Furthermore, an autonomous reference...

  19. Heuristic methods for single link shared backup path protection

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Stidsen, Thomas Riis; Zachariasen, Martin

    2014-01-01

    schemes are employed. In contrast to manual intervention, automatic protection schemes such as shared backup path protection (SBPP) can recover from failure quickly and efficiently. SBPP is a simple but efficient protection scheme that can be implemented in backbone networks with technology available...... today. In SBPP backup paths are planned in advance for every failure scenario in order to recover from failures quickly and efficiently. Planning SBPP is an NP-hard optimization problem, and previous work confirms that it is time-consuming to solve the problem in practice using exact methods.We present...... heuristic algorithms and lower bound methods for the SBPP planning problem. Experimental results show that the heuristic algorithms are able to find good quality solutions in minutes. A solution gap of less than 3.5 % was achieved for 5 of 7 benchmark instances (and a gap of less than 11 % for the remaining...

  20. Athletes Rated as Poor Single-Leg Squat Performers Display Measureable Differences in Single-Leg Squat Biomechanics Compared to Good Performers.

    Science.gov (United States)

    Garrick, Lachlan E; Alexander, Bryce C; Schache, Anthony G; Pandy, Marcus G; Crossley, Kay M; Collins, Natalie J

    2017-11-15

    It is important to validate single-leg squat visual rating criteria used in clinical practice and research. Foot orthoses may improve single-leg squat performance in those who demonstrate biomechanics associated with increased risk of lower-limb injury. Validate visual rating criteria proposed by Crossley et al, by determining whether athletes rated as poor single-leg squat performers display different single-leg squat biomechanics than good performers; and evaluate immediate effects of foot orthoses on single-leg squat biomechanics in poor performers. Comparative cross-sectional study. University laboratory. 79 asymptomatic athletes underwent video classification of single-leg squat performance based on established visual rating criteria (overall impression, trunk posture, pelvis 'in space', hip movement, knee movement), and were rated as good (n=23), fair (n=41) or poor (n=15) performers. A subset of good (n=16) and poor (n=12) performers underwent biomechanical assessment, completing five continuous single-leg squats on their dominant limb while three-dimensional motion analysis and ground reaction force data were recorded. Poor performers repeated the task standing on prefabricated foot orthoses. Peak external knee adduction moment (KAM) and peak angles for the trunk, hip, knee and ankle. Compared to good performers, poor performers had a significantly lower peak KAM (mean difference 0.11 Nm/kg, 95% confidence interval [CI] 0.02 to 0.2 Nm/kg), higher peak hip adduction angle (-4.3°, -7.6° to -0.9°), and higher peak trunk axial rotation towards their stance limb (3.8°, 0.4° to 7.2°). Foot orthoses significantly increased the peak KAM in poor performers (-0.06 Nm/kg, -0.1 to -0.01 Nm/kg), with values approximating those observed in good performers. Findings validate Crossley et al's visual rating criteria for single-leg squat performance in asymptomatic athletes, and suggest that 'off-the-shelf' foot orthoses may be a simple intervention for poor performers

  1. Rating the methodological quality of single-subject designs and n-of-1 trials: introducing the Single-Case Experimental Design (SCED) Scale.

    Science.gov (United States)

    Tate, Robyn L; McDonald, Skye; Perdices, Michael; Togher, Leanne; Schultz, Regina; Savage, Sharon

    2008-08-01

    Rating scales that assess methodological quality of clinical trials provide a means to critically appraise the literature. Scales are currently available to rate randomised and non-randomised controlled trials, but there are none that assess single-subject designs. The Single-Case Experimental Design (SCED) Scale was developed for this purpose and evaluated for reliability. Six clinical researchers who were trained and experienced in rating methodological quality of clinical trials developed the scale and participated in reliability studies. The SCED Scale is an 11-item rating scale for single-subject designs, of which 10 items are used to assess methodological quality and use of statistical analysis. The scale was developed and refined over a 3-year period. Content validity was addressed by identifying items to reduce the main sources of bias in single-case methodology as stipulated by authorities in the field, which were empirically tested against 85 published reports. Inter-rater reliability was assessed using a random sample of 20/312 single-subject reports archived in the Psychological Database of Brain Impairment Treatment Efficacy (PsycBITE). Inter-rater reliability for the total score was excellent, both for individual raters (overall ICC = 0.84; 95% confidence interval 0.73-0.92) and for consensus ratings between pairs of raters (overall ICC = 0.88; 95% confidence interval 0.78-0.95). Item reliability was fair to excellent for consensus ratings between pairs of raters (range k = 0.48 to 1.00). The results were replicated with two independent novice raters who were trained in the use of the scale (ICC = 0.88, 95% confidence interval 0.73-0.95). The SCED Scale thus provides a brief and valid evaluation of methodological quality of single-subject designs, with the total score demonstrating excellent inter-rater reliability using both individual and consensus ratings. Items from the scale can also be used as a checklist in the design, reporting and critical

  2. An Evaluation of the Use of Simulated Annealing to Optimize Thinning Rates for Single Even-Aged Stands

    Directory of Open Access Journals (Sweden)

    Kai Moriguchi

    2015-01-01

    Full Text Available We evaluated the potential of simulated annealing as a reliable method for optimizing thinning rates for single even-aged stands. Four types of yield models were used as benchmark models to examine the algorithm’s versatility. Thinning rate, which was constrained to 0–50% every 5 years at stand ages of 10–45 years, was optimized to maximize the net present value for one fixed rotation term (50 years. The best parameters for the simulated annealing were chosen from 113 patterns, using the mean of the net present value from 39 runs to ensure the best performance. We compared the solutions with those from coarse full enumeration to evaluate the method’s reliability and with 39 runs of random search to evaluate its efficiency. In contrast to random search, the best run of simulated annealing for each of the four yield models resulted in a better solution than coarse full enumeration. However, variations in the objective function for two yield models obtained with simulated annealing were significantly larger than those of random search. In conclusion, simulated annealing with optimized parameters is more efficient for optimizing thinning rates than random search. However, it is necessary to execute multiple runs to obtain reliable solutions.

  3. Changing Survival Rate of Infants Born Before 26 Gestational Weeks; Single-centre study

    Directory of Open Access Journals (Sweden)

    Asad Rahman

    2015-08-01

    Full Text Available Objectives: This study aimed to evaluate the changing survival rate and morbidities among infants born before 26 gestational weeks at the Sultan Qaboos University Hospital (SQUH in Muscat, Oman. Methods: This retrospective study assessed the mortality and morbidities of all premature infants born alive at 23–26 gestational weeks at SQUH between June 2006 and May 2013. Infants referred to SQUH within 72 hours of birth during this period were also included. Electronic records were reviewed for gestational age, gender, birth weight, maternal age, mode and place of delivery, antenatal steroid administration, morbidity and outcome. The survival rate was calculated and findings were then compared with those of a previous study conducted in the same hospital from 1991 to 1998. Rates of major morbidities were also calculated. Results: A total of 81 infants between 23–26 gestational weeks were admitted to the neonatal unit during the study period. Of these, 58.0% were male and 42.0% were female. Median gestational age was 25 weeks and mean birth weight was 770 ± 150 g. Of the 81 infants, 49 survived. The overall survival rate was 60.5% compared to 41% reported in the previous study. Respiratory distress syndrome (100.0%, retinopathy of prematurity (51.9%, bronchopulmonary dysplasia (34.6%, intraventricular haemorrhage (30.9% and patent ductus arteriosus (28.4% were the most common morbidities. Conclusion: The overall survival rate of infants between 23–26 gestational weeks during the study period had significantly improved in comparison to that found at the same hospital from 1991 to 1998. There is a need for the long-term neurodevelopmental follow-up of premature infants.

  4. Single photon imaging and timing array sensor apparatus and method

    Science.gov (United States)

    Smith, R. Clayton

    2003-06-24

    An apparatus and method are disclosed for generating a three-dimension image of an object or target. The apparatus is comprised of a photon source for emitting a photon at a target. The emitted photons are received by a photon receiver for receiving the photon when reflected from the target. The photon receiver determines a reflection time of the photon and further determines an arrival position of the photon on the photon receiver. An analyzer is communicatively coupled to the photon receiver, wherein the analyzer generates a three-dimensional image of the object based upon the reflection time and the arrival position.

  5. Methods for producing single crystal mixed halide perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Kai; Zhao, Yixin

    2017-07-11

    An aspect of the present invention is a method that includes contacting a metal halide and a first alkylammonium halide in a solvent to form a solution and maintaining the solution at a first temperature, resulting in the formation of at least one alkylammonium halide perovskite crystal, where the metal halide includes a first halogen and a metal, the first alkylammonium halide includes the first halogen, the at least one alkylammonium halide perovskite crystal includes the metal and the first halogen, and the first temperature is above about 21.degree. C.

  6. Optical Methods For Automatic Rating Of Engine Test Components

    Science.gov (United States)

    Pritchard, James R.; Moss, Brian C.

    1989-03-01

    In recent years, increasing commercial and legislative pressure on automotive engine manufacturers, including increased oil drain intervals, cleaner exhaust emissions and high specific power outputs, have led to increasing demands on lubricating oil performance. Lubricant performance is defined by bench engine tests run under closely controlled conditions. After test, engines are dismantled and the parts rated for wear and accumulation of deposit. This rating must be consistently carried out in laboratories throughout the world in order to ensure lubricant quality meeting the specified standards. To this end, rating technicians evaluate components, following closely defined procedures. This process is time consuming, inaccurate and subject to drift, requiring regular recalibration of raters by means of international rating workshops. This paper describes two instruments for automatic rating of engine parts. The first uses a laser to determine the degree of polishing of the engine cylinder bore, caused by the reciprocating action of piston. This instrument has been developed to prototype stage by the NDT Centre at Harwell under contract to Exxon Chemical, and is planned for production within the next twelve months. The second instrument uses red and green filtered light to determine the type, quality and position of deposit formed on the piston surfaces. The latter device has undergone feasibility study, but no prototype exists.

  7. Statistical Methods for Single-Particle Electron Cryomicroscopy

    DEFF Research Database (Denmark)

    Jensen, Katrine Hommelhoff

    , several randomly oriented copies of the protein are available, each representing a certain viewing direction of the structure. This implies two main computational problems: (1) to determine the angular relationship between the individual projection images, i.e. determine the protein pose in each view...... from the noisy, randomly oriented projection images. Many statistical approaches to SPR have been proposed in the past. Typically, due to the computation time complexity, they rely on approximated maximum likelihood (ML) or maximum a posteriori (MAP) estimate of the structure. All methods presented...... statistical inversion to optimally cope with the high amount of noise, as well as to incorporate prior information to obtain more reliable estimates. For the first problem, we investigate the statistical recovery of the geometry between a set of projection images. In more detail, we show the equivalence...

  8. Temperature and strain-rate dependence of the flow stress of ultrapure tantalum single crystals

    International Nuclear Information System (INIS)

    Werner, M.

    1987-01-01

    Measurements of the temperature dependence of the cyclic flow stress of ultrapure tantalum single crystals (RRR >∼ 14000) are extended to lower temperatures. After cyclic deformation well into saturation at 400 K, the temperature dependence of the flow stress is measured between 80 and 450 K at five different plastic resolved shear-strain rates, ε pl , in the range 2 x 10 -5 to 6 x 10 -3 s -1 . Below a critical temperature T k the flow stress is dominantly controlled by the mobility of screw dislocations. A recent theory of Seeger describes the 'thermal' component, σ*, of the flow stress (resolved shear stress) in the temperature and stress regime where the strain rate is determined by the formation and migration of kink pairs. The analytical expressions are valid in well-defined ranges of stress and temperature. The evaluation of the experimental data yields a value for the formation enthalpy of two isolated kinks 2H k = 0.98 eV. From the low-stress (σ* k = 2.0 x 10 -6 m 2 s -1 . The product of the density of mobile screw dislocations and the distance between insurmountable obstacles is found to be 2 x 10 -5 m -1 . The stress dependence of the kink-pair formation enthalpy H kp follows the theoretically predicted curve in the elastic-interaction stress regime. At the transition to the line-tension approximation (near σ* ∼ 80 MPa) the activation volume increases rather abruptly. Moreover, the quantitative analysis involves kinks other than those of minimum height. The most likely candidates are kinks on {211} planes. (author)

  9. Oxygen saturation and heart rate monitoring during a single session of early rehabilitation after cardiac surgery.

    Science.gov (United States)

    Sala, Vittorio; Petrucci, Lucia; Monteleone, Serena; Dall'Angelo, Anna; Miracca, Stefania; Conte, Teresa; Carlisi, Ettore; Ricotti, Susanna; D'Armini, Andrea M; Dalla Toffola, Elena

    2016-02-01

    Early rehabilitation after cardiac surgery aims to prevent immobilization, to reduce the effects of surgery on the respiratory function and to facilitate the recovery of autonomy in the activities of daily living (ADL), after discharge. Nevertheless the optimal perioperative physical therapy care for patients undergoing cardiac surgery is not well established. Moreover, most of the studies monitored peripheral oxygen saturation (SpO2) and heart rate (HR) during surgery or focused only on their recovery after rehabilitation and not on their pathways during a session of exercises. To monitor peripheral oxygen saturation and HR before, during and at the end of a single session of early rehabilitation after cardiac surgery, so testing our protocol's safety. A case series. Department of Cardiothoracic Surgery, inpatients. Forty-eight consecutive inpatients (35 M), mean age 61 years, with cardiovascular disease (CVD), who underwent cardiac surgery. We monitored SpO2%, HR, systemic blood pressure (BP), pain in the thoracic wound (VAS) and rate of perceived exertion (RPE) during the rehabilitation session after weaning from oxygen therapy. During all phases mean SpO2 was 94% (±1.8) and mean HR was 85 bpm (±13.3). Number of desaturation events were 14 in total and mean of % of time with SpO2<90% was 3 (±6.5) during all the rehabilitative session. Moreover, mean BP after reaching the sitting position was 124.7 (±11.9)/78.6 (±8.4) and after ambulation was 131.5 (±11.5)/82.9 (±7.3). The monitoring peripheral oxygen saturation and HR during and not only before and at the end of a standardized early rehabilitation session helped us to ensure the safety of our protocol. Because of its feasibility, safety and reproducibility our rehabilitation treatment has been applied to different types of surgical inpatients in order to limit the negative consequences of immobilization.

  10. What Predicts Method Effects in Child Behavior Ratings

    Science.gov (United States)

    Low, Justin A.; Keith, Timothy Z.; Jensen, Megan

    2015-01-01

    The purpose of this research was to determine whether child, parent, and teacher characteristics such as sex, socioeconomic status (SES), parental depressive symptoms, the number of years of teaching experience, number of children in the classroom, and teachers' disciplinary self-efficacy predict deviations from maternal ratings in a…

  11. In vitro comparison rate of dental root canal transportation using two single file systems on the simulated resin blocks

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Etesami

    2016-07-01

    Full Text Available Background and Aims: Cleaning and shaping is one of the most important stages in endodontic treatment. Single-file systems save time and reduce the risk of transmission of pathogens. This in vitro study was aimed to compare the rate of canal transportation after the preparation of the stimulated resin root canal with two single-file systems, namely Waveone and Reciproc. Materials and Methods: Thirty stimulated resin root canal blocks with size 8/0. 02 K file were randomly divided into two study groups. The preparation in Group A and Group B was performed using Reciproc and Waveone files, respectively. Pre and post- preparation photographs were taken and the images were superimposed to evaluate the inner and outer wall’s curvature tendency at three points (apical, middle and coronal using AutoCad pragram. Data were analyzed using T-test. Results: Based on the results, the degree of transportation in the inner and outer walls of the canal was less at the level of 3 millimeters (P0.05. Conclusion: Waveone showed better performance in the middle third of canal and this system maybe recommended.

  12. Methods of forecasting crack growth rate under creep conditions

    International Nuclear Information System (INIS)

    Ol'kin, S.I.

    1979-01-01

    Using construction aluminium alloy application possibility of linear mechanics of the destruction for quantitative description of crack development process under creepage conditions is investigated. It is shown, that the grade dependence between the stress intensity coefficient and the crack growth rate takes place only at certain combination of the sample geometry and creepage parameters, and consequently, its applicability in every given case must necessarily be tested experimentally

  13. Clustering method for counting passengers getting in a bus with single camera

    Science.gov (United States)

    Yang, Tao; Zhang, Yanning; Shao, Dapei; Li, Ying

    2010-03-01

    Automatic counting of passengers is very important for both business and security applications. We present a single-camera-based vision system that is able to count passengers in a highly crowded situation at the entrance of a traffic bus. The unique characteristics of the proposed system include, First, a novel feature-point-tracking- and online clustering-based passenger counting framework, which performs much better than those of background-modeling-and foreground-blob-tracking-based methods. Second, a simple and highly accurate clustering algorithm is developed that projects the high-dimensional feature point trajectories into a 2-D feature space by their appearance and disappearance times and counts the number of people through online clustering. Finally, all test video sequences in the experiment are captured from a real traffic bus in Shanghai, China. The results show that the system can process two 320×240 video sequences at a frame rate of 25 fps simultaneously, and can count passengers reliably in various difficult scenarios with complex interaction and occlusion among people. The method achieves high accuracy rates up to 96.5%.

  14. Reliability of the Parabola Approximation Method in Heart Rate Variability Analysis Using Low-Sampling-Rate Photoplethysmography.

    Science.gov (United States)

    Baek, Hyun Jae; Shin, JaeWook; Jin, Gunwoo; Cho, Jaegeol

    2017-10-24

    Photoplethysmographic signals are useful for heart rate variability analysis in practical ambulatory applications. While reducing the sampling rate of signals is an important consideration for modern wearable devices that enable 24/7 continuous monitoring, there have not been many studies that have investigated how to compensate the low timing resolution of low-sampling-rate signals for accurate heart rate variability analysis. In this study, we utilized the parabola approximation method and measured it against the conventional cubic spline interpolation method for the time, frequency, and nonlinear domain variables of heart rate variability. For each parameter, the intra-class correlation, standard error of measurement, Bland-Altman 95% limits of agreement and root mean squared relative error were presented. Also, elapsed time taken to compute each interpolation algorithm was investigated. The results indicated that parabola approximation is a simple, fast, and accurate algorithm-based method for compensating the low timing resolution of pulse beat intervals. In addition, the method showed comparable performance with the conventional cubic spline interpolation method. Even though the absolute value of the heart rate variability variables calculated using a signal sampled at 20 Hz were not exactly matched with those calculated using a reference signal sampled at 250 Hz, the parabola approximation method remains a good interpolation method for assessing trends in HRV measurements for low-power wearable applications.

  15. Doubling the single-dose infusion rate of tocilizumab in rheumatoid arthritis is safe and efficacious

    DEFF Research Database (Denmark)

    Lindegaard, H M; Johansen, P; Gröndal, G

    2016-01-01

    OBJECTIVES: To investigate the impact of enhanced infusion rate of tocilizumab on the occurrence of infusion reactions, overall safety, and efficacy in rheumatoid arthritis (RA). METHOD: We conducted a 24-week multicentre, open-label, randomized parallel group study comparing adverse event (AE......) and effect profiles following tocilizumab IV 8 mg/kg every 4 weeks over 31 min vs. standard 60-min infusions in patients with RA and an inadequate clinical response to disease-modifying anti-rheumatic drugs (DMARDs) and/or tumour necrosis factor (TNF)-α inhibitors. RESULTS: A total of 47 patients were...... enrolled in the study and randomized to fast infusions (n = 25) and controls (n = 22). Incidences of infusion reactions were similar between the two groups, neither of them leading to withdrawal. Likewise, the incidence of additional AEs did not differ between the treatment arms. Two serious adverse events...

  16. Comparison of two methods forecasting binding rate of plasma protein.

    Science.gov (United States)

    Hongjiu, Liu; Yanrong, Hu

    2014-01-01

    By introducing the descriptors calculated from the molecular structure, the binding rates of plasma protein (BRPP) with seventy diverse drugs are modeled by a quantitative structure-activity relationship (QSAR) technique. Two algorithms, heuristic algorithm (HA) and support vector machine (SVM), are used to establish linear and nonlinear models to forecast BRPP. Empirical analysis shows that there are good performances for HA and SVM with cross-validation correlation coefficients Rcv(2) of 0.80 and 0.83. Comparing HA with SVM, it was found that SVM has more stability and more robustness to forecast BRPP.

  17. The influence of nitrogen application, seeding rate and methods of ...

    African Journals Online (AJOL)

    The interaction between Trifolium vesiculosum cv. Amclo and Lolium multiflorum cv. Midmar in mixtures was measured in an irrigated field trial in terms of dry matter production, crude protein content and crude protein production. Two methods of mixing, namely mixing of the components in the same row and alternate rows ...

  18. Computing H/D-Exchange rates of single residues from data of proteolytic fragments

    Directory of Open Access Journals (Sweden)

    Althaus Ernst

    2010-08-01

    Full Text Available Abstract Background Protein conformation and protein/protein interaction can be elucidated by solution-phase Hydrogen/Deuterium exchange (sHDX coupled to high-resolution mass analysis of the digested protein or protein complex. In sHDX experiments mutant proteins are compared to wild-type proteins or a ligand is added to the protein and compared to the wild-type protein (or mutant. The number of deuteriums incorporated into the polypeptides generated from the protease digest of the protein is related to the solvent accessibility of amide protons within the original protein construct. Results In this work, sHDX data was collected on a 14.5 T FT-ICR MS. An algorithm was developed based on combinatorial optimization that predicts deuterium exchange with high spatial resolution based on the sHDX data of overlapping proteolytic fragments. Often the algorithm assigns deuterium exchange with single residue resolution. Conclusions With our new method it is possible to automatically determine deuterium exchange with higher spatial resolution than the level of digested fragments.

  19. Multi-rate cubature Kalman filter based data fusion method with residual compensation to adapt to sampling rate discrepancy in attitude measurement system.

    Science.gov (United States)

    Guo, Xiaoting; Sun, Changku; Wang, Peng

    2017-08-01

    This paper investigates the multi-rate inertial and vision data fusion problem in nonlinear attitude measurement systems, where the sampling rate of the inertial sensor is much faster than that of the vision sensor. To fully exploit the high frequency inertial data and obtain favorable fusion results, a multi-rate CKF (Cubature Kalman Filter) algorithm with estimated residual compensation is proposed in order to adapt to the problem of sampling rate discrepancy. During inter-sampling of slow observation data, observation noise can be regarded as infinite. The Kalman gain is unknown and approaches zero. The residual is also unknown. Therefore, the filter estimated state cannot be compensated. To obtain compensation at these moments, state error and residual formulas are modified when compared with the observation data available moments. Self-propagation equation of the state error is established to propagate the quantity from the moments with observation to the moments without observation. Besides, a multiplicative adjustment factor is introduced as Kalman gain, which acts on the residual. Then the filter estimated state can be compensated even when there are no visual observation data. The proposed method is tested and verified in a practical setup. Compared with multi-rate CKF without residual compensation and single-rate CKF, a significant improvement is obtained on attitude measurement by using the proposed multi-rate CKF with inter-sampling residual compensation. The experiment results with superior precision and reliability show the effectiveness of the proposed method.

  20. /sup 99m/Tc-DTPA scintillation-camera renography: a new method for estimation of single-kidney function

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Moeller, M.L.; Trap-Jensen, J.

    1977-01-01

    A new method of combined serial scintigraphy and renography, using a scintillation camera and /sup 99m/Tc-DTPA is evaluated. Renographic curves, corresponding to light-pen ''areas of interest'' over the renal parenchyma, were processed. ''Blood-background'' curves were recorded from an external detector over the temporal region of the head and also from an ''area of interest'' corresponding to the aorta and inferior vena cava. The uptake phase of the renogram was always linear. The sum of the slopes of the uptake phase of both kidneys correlated well with the measured glomerular filtration rate in 25 patients with renal insufficiency of various degrees. Single-kidney function estimated from the slopes correlated reasonably well with single-kidney function estimated from 131 I-Hippuran renography with external detectors. The method described minimizes errors in the estimation of single-kidney function, and both anatomic and functional information is obtained

  1. Single-mode, Rayleigh-Taylor growth-rate measurements on the OMEGA laser system

    International Nuclear Information System (INIS)

    Knauer, J. P.; Betti, R.; Bradley, D. K.; Boehly, T. R.; Collins, T. J. B.; Goncharov, V. N.; McKenty, P. W.; Meyerhofer, D. D.; Smalyuk, V. A.; Verdon, C. P.

    2000-01-01

    The results from a series of single-mode, Rayleigh-Taylor (RT) instability growth experiments performed on the OMEGA laser system [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] using planar targets are reported. Planar targets with imposed mass perturbations were accelerated using five or six 351 nm laser beams overlapped with total intensities up to 2.5x10 14 W/cm 2 . Experiments were performed with both 3 ns ramp and 3 ns flat-topped temporal pulse shapes. The use of distributed phase plates and smoothing by spectral dispersion resulted in a laser-irradiation nonuniformity of 4%-7% over a 600 μm diam region defined by the 90% intensity contour. The temporal growth of the modulation in optical depth was measured using throughfoil radiography and was detected with an x-ray framing camera for CH targets. Two-dimensional (2-D) hydrodynamic simulations (ORCHID) [R. L. McCrory and C. P. Verdon, in Inertial Confinement Fusion (Editrice Compositori, Bologna, 1989), pp. 83-124] of the growth of 20, 31, and 60 μm wavelength perturbations were in good agreement with the experimental data when the experimental details, including noise, were included. The amplitude of the simulation optical depth is in good agreement with the experimental optical depth; therefore, great care must be taken when the growth rates are compared to dispersion formulas. Since the foil's initial condition just before it is accelerated is not that of a uniformly compressed foil, the optical density measurement does not accurately reflect the amplitude of the ablation surface but is affected by the initial nonuniform density profile. (c) 2000 American Institute of Physics

  2. Infection Rate after Cranial Neurosurgical Procedures: A Prospective Single-Center Study.

    Science.gov (United States)

    Strahm, Carol; Albrich, Werner C; Zdravkovic, Vilijam; Schöbi, Barbara; Hildebrandt, Gerhard; Schlegel, Matthias

    2018-03-01

    To determine infection rate (IR) and to identify modifiable risk factors (RF) in cranial neurosurgery in a neurosurgical department for tertiary referral as part of an infection control surveillance to reduce surgical site infections (SSI). A prospective SSI incidence cohort study from February 2013 to January 2014 was performed in a tertiary-care neurosurgical teaching hospital and referral center. All consecutive adults undergoing any cranial neurosurgical procedure were included. Data were collected by a trained member of the infection control staff during the twice-weekly visits of the hospitalized patients. Follow-up was 30 days (procedures without implant) and 1 year (procedures involving permanent implants). SSI was diagnosed according to criteria of CDC. A total of 317 patients undergoing 333 index procedures were included. The median age was 61 years (range, 17-91 years) and 46% were female. Survival in patients with completed follow-up was 76% (196/258). Overall, IR was 7.2% (24/333 index procedures); in 96% (23/24), a neurosurgical implant was involved. The IR of extraventricular drainage (EVD) was 12.5% (13.1/1000 EVD days). The main causative pathogens were Staphylococcus aureus followed by coagulase-negative staphylococci and Propionibacterium acnes. Independent RF for neurosurgical SSI were EVD as part of the index operation and body mass index >25 kg/m 2 . IR was in accordance with recent prospective single-center studies (reported IR between 1.6% and 9%). EVD placement was identified as the strongest modifiable RF for SSI in cranial neurosurgical procedures. The need for standard infection control procedures for the insertion and maintenance of EVDs to avoid their contamination is reinforced. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Single-well tracer methods for hydrogeologic evaluation of target aquifers

    International Nuclear Information System (INIS)

    Hall, S.H.

    1994-11-01

    Designing an efficient well field for an aquifer thermal energy storage (ATES) project requires measuring local groundwater flow parameters as well as estimating horizontal and vertical inhomogeneity. Effective porosity determines the volume of aquifer needed to store a given volume of heated or chilled water. Ground-water flow velocity governs the migration of the thermal plume, and dispersion and heat exchange along the flow path reduces the thermal intensity of the recovered plume. Stratigraphic variations in the aquifer will affect plume dispersion, may bias the apparent rate of migration of the plume, and can prevent efficient hydraulic communication between wells. Single-well tracer methods using a conservative flow tracer such as bromide, along with pumping tests and water-level measurements, provide a rapid and cost-effective means for estimating flow parameters. A drift-and-pumpback tracer test yields effective porosity and flow velocity. Point-dilution tracer testing, using new instrumentation for downhole tracer measurement and a new method for calibrating the point-dilution test itself, yields depth-discrete hydraulic conductivity as it is affected by stratigraphy, and can be used to estimate well transmissivity. Experience in conducting both drift-and-pumpback and point-dilution tests at three different test sites has yielded important information that highlights both the power and the limitations of the single-well tracer methods. These sites are the University of Alabama Student Recreation Center (UASRC) ATES well field and the VA Medical Center (VA) ATES well field, both located in Tuscaloosa, Alabama, and the Hanford bioremediation test site north of Richland, Washington

  4. The rate of convergence in the method of alternating projections

    Czech Academy of Sciences Publication Activity Database

    Badea, C.; Grivaux, S.; Müller, Vladimír

    2012-01-01

    Roč. 23, č. 3 (2012), s. 413-434 ISSN 1061-0022 R&D Projects: GA ČR GA201/09/0473; GA AV ČR IAA100190903 Institutional support: RVO:67985840 Keywords : Friedrichs angle * method of alternating projections * arbitrarily slow convergence Subject RIV: BA - General Mathematics Impact factor: 0.460, year: 2012 http://www.ams.org/journals/spmj/2012-23-03/S1061-0022-2012-01202-1/home.html

  5. Error baseline rates of five sample preparation methods used to characterize RNA virus populations

    Science.gov (United States)

    Kugelman, Jeffrey R.; Wiley, Michael R.; Nagle, Elyse R.; Reyes, Daniel; Pfeffer, Brad P.; Kuhn, Jens H.; Sanchez-Lockhart, Mariano; Palacios, Gustavo F.

    2017-01-01

    Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic “no amplification” method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a “targeted” amplification method, sequence-independent single-primer amplification (SISPA) as a “random” amplification method, rolling circle reverse transcription sequencing (CirSeq) as an advanced “no amplification” method, and Illumina TruSeq RNA Access as a “targeted” enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4−5) of all compared methods. PMID:28182717

  6. Dose rate effect on micronuclei induction in human blood lymphocytes exposed to single pulse and multiple pulses of electrons.

    Science.gov (United States)

    Acharya, Santhosh; Bhat, N N; Joseph, Praveen; Sanjeev, Ganesh; Sreedevi, B; Narayana, Y

    2011-05-01

    The effects of single pulses and multiple pulses of 7 MV electrons on micronuclei (MN) induction in cytokinesis-blocked human peripheral blood lymphocytes (PBLs) were investigated over a wide range of dose rates per pulse (instantaneous dose rate). PBLs were exposed to graded doses of 2, 3, 4, 6, and 8 Gy of single electron pulses of varying pulse widths at different dose rates per pulse, ranging from 1 × 10(6) Gy s(-1) to 3.2 × 10(8) Gy s(-1). Different dose rates per pulse were achieved by changing the dose per electron pulse by adjusting the beam current and pulse width. MN yields per unit absorbed dose after irradiation with single electron pulses were compared with those of multiple pulses of electrons. A significant decrease in the MN yield with increasing dose rates per pulse was observed, when dose was delivered by a single electron pulse. However, no reduction in the MN yield was observed when dose was delivered by multiple pulses of electrons. The decrease in the yield at high dose rates per pulse suggests possible radical recombination, which leads to decreased biological damage. Cellular response to the presence of very large numbers of chromosomal breaks may also alter the damage.

  7. Response matrix method and its application to SCWR single channel stability analysis

    International Nuclear Information System (INIS)

    Zhao, Jiyun; Tseng, K.J.; Tso, C.P.

    2011-01-01

    To simulate the reactor system dynamic features during density wave oscillations (DWO), both the non-linear method and the linear method can be used. Although some transient information is lost through model linearization, the high computational efficiency and relatively accurate results make the linear analysis methodology attractive, especially for prediction of the onset of instability. In the linear stability analysis, the system models are simplified through linearization of the complex non-linear differential equations, and then, the linear differential equations are generally solved in the frequency domain through Laplace transformation. In this paper, a system response matrix method was introduced by directly solving the differential equations in the time domain. By using a system response matrix method, the complicated transfer function derivation, which must be done in the frequency domain method, can be avoided. Using the response matrix method, a model was developed and applied to the single channel or parallel channel type instability analyses of the typical proposed SCWR design. The sensitivity of the decay ratio (DR) to the axial mesh size was analyzed and it was found that the DR is not sensitive to mesh size once sufficient number of axial nodes is applied. To demonstrate the effects of the inlet orificing to the stability feature for the supercritical condition, the sensitivity of the stability to inlet orifice coefficient was conducted for hot channel. It is clearly shown that a higher inlet orifice coefficient will make the system more stable. The susceptibility of stability to operating parameters such as mass flow rate, power and system pressure was also performed. And the measure to improve the SCWR stability sensitivity to operating parameters was investigated. It was found that the SCWR stability sensitivity feature can be improved by carefully managing the inlet orifices and choosing proper operating parameters. (author)

  8. A distribution-based method to resolve single-molecule Förster resonance energy transfer observations.

    Science.gov (United States)

    Backović, Mihailo; Price, E Shane; Johnson, Carey K; Ralston, John P

    2011-04-14

    We introduce a new approach to analyze single-molecule Förster resonance energy transfer (FRET) data. The method recognizes that FRET efficiencies assumed by traditional ensemble methods are unobservable for single molecules. We propose instead a method to predict distributions of FRET parameters obtained directly from the data. Distributions of FRET rates, given the data, are precisely defined using Bayesian methods and increase the information derived from the data. Benchmark comparisons find that the response time of the new method outperforms traditional methods of averaging. Our approach makes no assumption about the number or distribution of underlying FRET states. The new method also yields information about joint parameter distributions going beyond the standard framework of FRET analysis. For example, the running distribution of FRET means contains more information than any conceivable single measure of FRET efficiency. The method is tested against simulated data and then applied to a pilot-study sample of calmodulin molecules immobilized in lipid vesicles, revealing evidence for multiple dynamical states.

  9. Improvement of single detector proton radiography by incorporating intensity of time-resolved dose rate functions

    Science.gov (United States)

    Zhang, Rongxiao; Jee, Kyung-Wook; Cascio, Ethan; Sharp, Gregory C.; Flanz, Jacob B.; Lu, Hsiao-Ming

    2018-01-01

    Proton radiography, which images patients with the same type of particles as those with which they are to be treated, is a promising approach to image guidance and water equivalent path length (WEPL) verification in proton radiation therapy. We have shown recently that proton radiographs could be obtained by measuring time-resolved dose rate functions (DRFs) using an x-ray amorphous silicon flat panel. The WEPL values were derived solely from the root-mean-square (RMS) of DRFs, while the intensity information in the DRFs was filtered out. In this work, we explored the use of such intensity information for potential improvement in WEPL accuracy and imaging quality. Three WEPL derivation methods based on, respectively, the RMS only, the intensity only, and the intensity-weighted RMS were tested and compared in terms of the quality of obtained radiograph images and the accuracy of WEPL values. A Gammex CT calibration phantom containing inserts made of various tissue substitute materials with independently measured relative stopping powers (RSP) was used to assess the imaging performances. Improved image quality with enhanced interfaces was achieved while preserving the accuracy by using intensity information in the calibration. Other objects, including an anthropomorphic head phantom, a proton therapy range compensator, a frozen lamb’s head and an ‘image quality phantom’ were also imaged. Both the RMS only and the intensity-weighted RMS methods derived RSPs within  ±  1% for most of the Gammex phantom inserts, with a mean absolute percentage error of 0.66% for all inserts. In the case of the insert with a titanium rod, the method based on RMS completely failed, whereas that based on the intensity-weighted RMS was qualitatively valid. The use of intensity greatly enhanced the interfaces between different materials in the obtained WEPL images, suggesting the potential for image guidance in areas such as patient positioning and tumor tracking by proton

  10. Imaging method for monitoring delivery of high dose rate brachytherapy

    Science.gov (United States)

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  11. A Benchmark of Lidar-Based Single Tree Detection Methods Using Heterogeneous Forest Data from the Alpine Space

    Directory of Open Access Journals (Sweden)

    Lothar Eysn

    2015-05-01

    Full Text Available In this study, eight airborne laser scanning (ALS-based single tree detection methods are benchmarked and investigated. The methods were applied to a unique dataset originating from different regions of the Alpine Space covering different study areas, forest types, and structures. This is the first benchmark ever performed for different forests within the Alps. The evaluation of the detection results was carried out in a reproducible way by automatically matching them to precise in situ forest inventory data using a restricted nearest neighbor detection approach. Quantitative statistical parameters such as percentages of correctly matched trees and omission and commission errors are presented. The proposed automated matching procedure presented herein shows an overall accuracy of 97%. Method based analysis, investigations per forest type, and an overall benchmark performance are presented. The best matching rate was obtained for single-layered coniferous forests. Dominated trees were challenging for all methods. The overall performance shows a matching rate of 47%, which is comparable to results of other benchmarks performed in the past. The study provides new insight regarding the potential and limits of tree detection with ALS and underlines some key aspects regarding the choice of method when performing single tree detection for the various forest types encountered in alpine regions.

  12. Servohydraulic methods for mechanical testing in the Sub-Hopkinson rate regime up to strain rates of 500 1/s.

    Energy Technology Data Exchange (ETDEWEB)

    Crenshaw, Thomas B.; Boyce, Brad Lee

    2005-10-01

    Tensile and compressive stress-strain experiments on metals at strain rates in the range of 1-1000 1/s are relevant to many applications such as gravity-dropped munitions and airplane accidents. While conventional test methods cover strain rates up to {approx}10 s{sup -1} and split-Hopkinson and other techniques cover strain rates in excess of {approx}1000 s{sup -1}, there are no well defined techniques for the intermediate or ''Sub-Hopkinson'' strain-rate regime. The current work outlines many of the challenges in testing in the Sub-Hopkinson regime, and establishes methods for addressing these challenges. The resulting technique for obtaining intermediate rate stress-strain data is demonstrated in tension on a high-strength, high-toughness steel alloy (Hytuf) that could be a candidate alloy for earth penetrating munitions and in compression on a Au-Cu braze alloy.

  13. When the Single Matters more than the Group (II): Addressing the Problem of High False Positive Rates in Single Case Voxel Based Morphometry Using Non-parametric Statistics.

    Science.gov (United States)

    Scarpazza, Cristina; Nichols, Thomas E; Seramondi, Donato; Maumet, Camille; Sartori, Giuseppe; Mechelli, Andrea

    2016-01-01

    In recent years, an increasing number of studies have used Voxel Based Morphometry (VBM) to compare a single patient with a psychiatric or neurological condition of interest against a group of healthy controls. However, the validity of this approach critically relies on the assumption that the single patient is drawn from a hypothetical population with a normal distribution and variance equal to that of the control group. In a previous investigation, we demonstrated that family-wise false positive error rate (i.e., the proportion of statistical comparisons yielding at least one false positive) in single case VBM are much higher than expected (Scarpazza et al., 2013). Here, we examine whether the use of non-parametric statistics, which does not rely on the assumptions of normal distribution and equal variance, would enable the investigation of single subjects with good control of false positive risk. We empirically estimated false positive rates (FPRs) in single case non-parametric VBM, by performing 400 statistical comparisons between a single disease-free individual and a group of 100 disease-free controls. The impact of smoothing (4, 8, and 12 mm) and type of pre-processing (Modulated, Unmodulated) was also examined, as these factors have been found to influence FPRs in previous investigations using parametric statistics. The 400 statistical comparisons were repeated using two independent, freely available data sets in order to maximize the generalizability of the results. We found that the family-wise error rate was 5% for increases and 3.6% for decreases in one data set; and 5.6% for increases and 6.3% for decreases in the other data set (5% nominal). Further, these results were not dependent on the level of smoothing and modulation. Therefore, the present study provides empirical evidence that single case VBM studies with non-parametric statistics are not susceptible to high false positive rates. The critical implication of this finding is that VBM can be used

  14. Method for obtaining secondary amines from nitrobenzene in a single reactor

    OpenAIRE

    Corma, Avelino; Leyva, Antonio; Rubio Marqués, Paula

    2012-01-01

    [EN] The invention relates to a method for directly obtaining secondary amines, such as, for example, cyclohexylaniline or dicyclohexylaniline and substituted derivatives thereof, from nitrobenzene and derivatives in a single reactor, characterised in that: a nitrobenzene derivative, a solid catalyst, a solvent, an acid and hydrogen are introduced into the reactor, and it comprises a single step (one pot)

  15. Photovoltaic device using single wall carbon nanotubes and method of fabricating the same

    Science.gov (United States)

    Biris, Alexandru S.; Li, Zhongrui

    2012-11-06

    A photovoltaic device and methods for forming the same. In one embodiment, the photovoltaic device has a silicon substrate, and a film comprising a plurality of single wall carbon nanotubes disposed on the silicon substrate, wherein the plurality of single wall carbon nanotubes forms a plurality of heterojunctions with the silicon in the substrate.

  16. Single-cell epigenomics: powerful new methods for understanding gene regulation and cell identity.

    Science.gov (United States)

    Clark, Stephen J; Lee, Heather J; Smallwood, Sébastien A; Kelsey, Gavin; Reik, Wolf

    2016-04-18

    Emerging single-cell epigenomic methods are being developed with the exciting potential to transform our knowledge of gene regulation. Here we review available techniques and future possibilities, arguing that the full potential of single-cell epigenetic studies will be realized through parallel profiling of genomic, transcriptional, and epigenetic information.

  17. Cavity-enhanced radiative emission rate in a single-photon-emitting diode operating at 0.5 GHz

    International Nuclear Information System (INIS)

    Ellis, David J P; Bennett, Anthony J; Dewhurst, Samuel J; Shields, Andrew J; Nicoll, Christine A; Ritchie, David A

    2008-01-01

    We report the observation of a Purcell enhancement in the radiative decay rate of a single quantum dot, embedded in a microcavity light-emitting-diode structure. Lateral confinement of the optical mode was achieved using an annulus of low-refractive-index aluminium oxide, formed by wet oxidation. The same layer acts as a current aperture, reducing the active area of the device without impeding the electrical properties of the p-i-n diode. This allowed single photon electroluminescence to be demonstrated at repetition rates up to 0.5 GHz

  18. Comparison of Inversion (“flipping”) Rates Among Different Port Designs: A Single-Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Etezadi, Vahid, E-mail: vahid.etezadi@umm.edu; Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu [University of Pennsylvania Medical Center, Division of Interventional Radiology, Department of Radiology (United States)

    2017-04-15

    PurposeTo compare incidence of port inversion among different types of implantable venous access devices.Materials and Methods Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated.Results Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7–580).Conclusion The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design.Level of Evidence: Case Series, Level IV.

  19. Application of dead-reckoning in the single-base station location and tracking method

    Science.gov (United States)

    Zhang, Ruyun; Fan, Dandan; Xu, Mingyan; Chen, Ming

    2007-11-01

    A location and tracking method utilizing Dead-Reckoning using single base station in cellular networks is proposed in this paper. Extended Kalman Filter (EKF) and the location method utilizing the AOA and the variance ratio of AOA are introduced to smooth the measurement error. The simulation result is illustrated to explain the location and tracking efficiency of the proposed method.

  20. A new method for solving single and multi-objective fuzzy minimum ...

    Indian Academy of Sciences (India)

    Several authors have proposed different methods for solving fuzzy minimum cost flow (MCF) problems. In this paper, some single and multi-objective fuzzy MCF problems are chosen which cannot be solved by using any of the existing methods and a new method is proposed for solving such type of problems. The main ...

  1. Effect of skin coverage method following subcuticular suturing on wound infection rates at cesarean delivery.

    Science.gov (United States)

    Westcott, Jill M; Crockett, Libby; Qiu, Fang; Berg, Teresa G

    2017-08-01

    The objective of this study was to determine whether the use of cyanoacrylate skin glue following subcuticular skin closure was associated with a decrease in wound outcomes in comparison with subcuticular closure plus Steri-strips at cesarean delivery. This was a retrospective cohort study of patients undergoing cesarean delivery at a single center over a two-year period. The primary outcome of wound infection and secondary outcomes of wound separation and composite wound complication rate were assessed throughout the six-week postpartum period. Of 660 women who met inclusion criteria, 35 (5.3%) experienced a wound infection and 90 (13.6%) experienced a wound separation. The composite wound complication rate was 16.4% (n = 108). Of the 515 cases with a skin coverage method noted, use of skin glue was associated with a marginal decrease in wound infections (p = 0.057), as well as a significantly reduced incidence of wound separation (p = 0.03) and composite wound complications (p = 0.006). Cyanoacrylate skin glue may be superior to Steri-strips for wound separation and composite wound complication rates when utilized with subcuticular suture at the time of cesarean delivery and may yield some benefit for prevention of wound infection.

  2. A two-step computer-assisted method for deriving steady-state rate equations.

    Science.gov (United States)

    Fromm, S J; Fromm, H J

    1999-11-19

    A number of computer-assisted methods have been described for the derivation of enzyme-catalyzed steady-state rate equations [K. R. Runyan and R. B. Gunn (1989) Methods Enzymol. 171, 164-190; R. Varon, F. Garcia-Seville, M. Garvia-Moreno, F. Garcia-Canovas, R. Peyro, and R. G. Duggleby (1997) Comput. Appl. Biosci. 13, 159-167]; however, the required programs are either not readily available or require special software. We present here a two-step computer-assisted procedure for deriving steady-state rate equations using the widely available program Mathematica. In the first step, the differential equations for a particular kinetic mechanism that describe changes in enzyme concentration as a function of time are set equal to zero and entered into Mathematica in matrix form. In the second step, a single command allows for the computation of the distribution equations for the free enzyme and each enzyme-ligand complex. Copyright 1999 Academic Press.

  3. Bit Error Rate Minimizing Channel Shortening Equalizers for Single Carrier Cyclic Prefixed Systems

    National Research Council Canada - National Science Library

    Martin, Richard K; Vanbleu, Koen; Ysebaert, Geert

    2007-01-01

    .... Previous work on channel shortening has largely been in the context of digital subscriber lines, a wireline system that allows bit allocation, thus it has focused on maximizing the bit rate for a given bit error rate (BER...

  4. High Energy Single Frequency Fiber Laser at Low Repetition Rate, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR phase I project proposes a tunable single frequency high energy fiber laser system for coherent Lidar systems for remote sensing. Current state-of-art...

  5. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Sleep disorders are typically investigated by means of polysomnographic recordings. We have analyzed 70 eight-hour single-channel ECG recordings to find out to which extent sleep apneas may be detected from the ECG alone...

  6. Life cycle and population growth rate of Caenorhabditis elegans studied by a new method

    Directory of Open Access Journals (Sweden)

    Schroeder Fabian

    2009-05-01

    Full Text Available Abstract Background The free-living nematode Caenorhabditis elegans is the predominant model organism in biological research, being used by a huge number of laboratories worldwide. Many researchers have evaluated life-history traits of C. elegans in investigations covering quite different aspects such as ecotoxicology, inbreeding depression and heterosis, dietary restriction/supplement, mutations, and ageing. Such traits include juvenile growth rates, age at sexual maturity, adult body size, age-specific fecundity/mortality, total reproduction, mean and maximum lifespan, and intrinsic population growth rates. However, we found that in life-cycle experiments care is needed regarding protocol design. Here, we test a recently developed method that overcomes some problems associated with traditional cultivation techniques. In this fast and yet precise approach, single individuals are maintained within hanging drops of semi-fluid culture medium, allowing the simultaneous investigation of various life-history traits at any desired degree of accuracy. Here, the life cycles of wild-type C. elegans strains N2 (Bristol, UK and MY6 (Münster, Germany were compared at 20°C with 5 × 109 Escherichia coli ml-1 as food source. Results High-resolution life tables and fecundity schedules of the two strains are presented. Though isolated 700 km and 60 years apart from each other, the two strains barely differed in life-cycle parameters. For strain N2 (n = 69, the intrinsic rate of natural increase (rmd-1, calculated according to the Lotka equation, was 1.375, the net reproductive rate (R0 291, the mean generation time (T 90 h, and the minimum generation time (Tmin 73.0 h. The corresponding values for strain MY6 (n = 72 were rm = 1.460, R0 = 289, T = 84 h, and Tmin = 67.3 h. Peak egg-laying rates in both strains exceeded 140 eggs d-1. Juvenile and early adulthood mortality was negligible. Strain N2 lived, on average, for 16.7 d, while strain MY6 died 2 days

  7. Imaging by the SSFSE single slice method at different viscosities of bile

    International Nuclear Information System (INIS)

    Kubo, Hiroya; Usui, Motoki; Fukunaga, Kenichi; Yamamoto, Naruto; Ikegami, Toshimi

    2001-01-01

    The single shot fast spin echo single thick slice method (single slice method) is a technique that visualizes the water component alone using a heavy T 2 . However, this method is considered to be markedly affected by changes in the viscosity of the material because a very long TE is used, and changes in the T 2 value, which are related to viscosity, directly affect imaging. In this study, we evaluated the relationship between the effects of TE and the T 2 value of bile in the single slice method and also examined the relationship between the signal intensity of bile on T 1 - and T 2 -weighted images and imaging by MR cholangiography (MRC). It was difficult to image bile with high viscosities at a usual effective TE level of 700-1,500 ms. With regard to the relationship between the signal intensity of bile and MRC imaging, all T 2 values of the bile samples showing relatively high signal intensities on the T 1 -weighted images suggested high viscosities, and MRC imaging of these bile samples was poor. In conclusion, MRC imaging of bile with high viscosities was poor with the single slice method. Imaging by the single slice method alone of bile showing a relatively high signal intensity on T 1 -weighted images should be avoided, and combination with other MRC sequences should be used. (author)

  8. Effect of air velocity on the drying rate of single eastern white pine boards

    Science.gov (United States)

    W. T. Simpson

    1997-01-01

    The qualitative effect of air velocity on drying rate of lumber has long been known. This report provides quantification of the effects of air velocity on drying rate of individual eastern white pine boards. An empirical equation correlating moisture content with time during drying was used to aid in the analysis. The drying rate increased with air velocity for...

  9. Nanolithography based contacting method for electrical measurements on single template synthesized nanowires

    DEFF Research Database (Denmark)

    Fusil, S.; Piraux, L.; Mátéfi-Tempfli, Stefan

    2005-01-01

    A reliable method enabling electrical measurements on single nanowires prepared by electrodeposition in an alumina template is described. This technique is based on electrically controlled nanoindentation of a thin insulating resist deposited on the top face of the template filled by the nanowires....... We show that this method is very flexible, allowing us to electrically address single nanowires of controlled length down to 100 nm and of desired composition. Using this approach, current densities as large as 10 A cm were successfully injected through a point contact on a single magnetic...

  10. Early and late preterm delivery rates - a comparison of differing tocolytic policies in a single urban population.

    LENUS (Irish Health Repository)

    Hehir, Mark P

    2012-11-01

    Preterm delivery results in neonatal morbidity and mortality. We set out to estimate the difference in rates of preterm delivery in two institutions, serving a single population, with differing policies regarding use of tocolytic drugs for the prevention of preterm delivery.

  11. Comparison of Model Reliabilities from Single-Step and Bivariate Blending Methods

    DEFF Research Database (Denmark)

    Taskinen, Matti; Mäntysaari, Esa; Lidauer, Martin

    2013-01-01

    the production trait evaluation of Nordic Red dairy cattle. Genotyped bulls with daughters are used as training animals, and genotyped bulls and producing cows as candidate animals. For simplicity, size of the data is chosen so that the full inverses of the mixed model equation coefficient matrices can......Model based reliabilities in genetic evaluation are compared between three methods: animal model BLUP, single-step BLUP, and bivariate blending after genomic BLUP. The original bivariate blending is revised in this work to better account animal models. The study data is extracted from...... be calculated. Model reliabilities by the single-step and the bivariate blending methods were higher than by animal model due to genomic information. Compared to the single-step method, the bivariate blending method reliability estimates were, in general, lower. Computationally bivariate blending method was...

  12. Rating

    OpenAIRE

    Karas, Vladimír

    2006-01-01

    Charakteristika ratingu. Dělení a druhy ratingu (rating emise × rating emitenta; dlouhodobý rating × krátkodobý rating; mezinárodní rating × lokální rating). Obecné požadavky kladené na rating. Proces tvorby ratingu. Vyžádaný rating. Nevyžádaný rating. Ratingový proces na bázi volně přístupných informací. Uplatňované ratingové systémy. Ratingová kriteria. Využití a interpretace ratingové známky. Funkce ratingu. Rating v souvislosti s BASEL II. Rating v souvislosti s hospodářskými krizemi....

  13. 77 FR 31756 - Energy Conservation Program: Alternative Efficiency Determination Methods and Alternative Rating...

    Science.gov (United States)

    2012-05-30

    ...-AC46 Energy Conservation Program: Alternative Efficiency Determination Methods and Alternative Rating... for AEDMs and its proposal to no longer require pre-approval for use of an alternative rating method... model tested by DOE fails to meet its certified rating. 7. DOE requests comment on the proposal to...

  14. A Novel High-Resolution Method for the Respiration Rate and Breathing Waveforms Remote Monitoring.

    Science.gov (United States)

    Vainer, Boris G

    2018-04-04

    A search for robust noninvasive methods permitting to discern the respiration subtle peculiarities in mammals is a topical issue. A novel approach called "sorption-enhanced infrared thermography" (SEIRT), helping to solve this problem, is described. Its benefits spring from the integration of the infrared thermography (IRT) and chemical physics (phase transition heat release/absorption) within a single method. The SEIRT opportunities were verified in the investigation of 42 humans, 49 rats and 4 minipigs whose breathing waveforms were revealed to the last detail. It is shown that the SEIRT-obtained breathing-conditioned temperature response may exceed 10 °C (!) even in small animals (rats) and that the SEIRT sensitivity is 4.5-250 times higher than that of the matched IRT-based techniques. The new method is validated by a comparison with that based on thorax breathing movement (TBM). It is shown that the SEIRT-determined breaths have a close correlation with those determined via TBM (r = + 1.000, p ≪ 0.05); this is also true for breathing intervals (r = + 0.9772, p ≪ 0.05). SEIRT opens up the way to a high-resolution noncontact quantitative evaluation of respiration rate and breathing waveforms in both humans and animals. It may become a cutting-edge technique in diagnostic medicine and biomedical research.

  15. Reliability of single kidney glomerular filtration rate measured by a 99mTc-DTPA gamma camera technique

    International Nuclear Information System (INIS)

    Rehling, M.; Moller, M.L.; Jensen, J.J.; Thamdrup, B.; Lund, J.O.; Trap-Jensen, J.

    1986-01-01

    The reliability of a previously published method for determination of single kidney glomerular filtration rate (SKGFR) by means of technetium-99m-diethylenetriaminepenta-acetate (99mTc-DTPA) gamma camera renography was evaluated. The day-to-day variation in the calculated SKGFR values was earlier found to be 8.8%. The technique was compared to the simultaneously measured renal clearance of inulin in 19 unilaterally nephrectomized patients with GFR varying from 11 to 76 ml/min. The regression line (y = 1.04 X -2.5) did not differ significantly from the line of identity. The standard error of estimate was 4.3 ml/min. In 17 patients the inter- and intraobserver variation of the calculated SKGFR values was 1.2 ml/min and 1.3 ml/min, respectively. In 21 of 25 healthy subjects studied (age range 27-29 years), total GFR calculated from the renograms was within an established age-dependent normal range of GFR

  16. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Our analysis is based on spectral components of heart rate variability. Frequency analysis was performed using Fourier and wavelet transformation with appropriate application of the Hilbert transform...

  17. Are single-well "push-pull" tests suitable tracer methods for aquifer characterization?

    Science.gov (United States)

    Hebig, Klaus; Zeilfelder, Sarah; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao

    2013-04-01

    Recently, investigations were conducted for geological and hydrogeological characterisation of the sedimentary coastal basin of Horonobe (Hokkaido, Japan). Coastal areas are typical geological settings in Japan, which are less tectonically active than the mountain ranges. In Asia, and especially in Japan, these areas are often densely populated. Therefore, it is important to investigate the behaviour of solutes in such unconsolidated aquifers. In such settings sometimes only single boreholes or groundwater monitoring wells are available for aquifer testing for various reasons, e.g. depths of more than 100 m below ground level and slow groundwater velocities due to density driven flow. A standard tracer test with several involved groundwater monitoring wells is generally very difficult or even not possible at these depths. One of the most important questions in our project was how we can obtain information about chemical and hydraulic properties in such aquifers. Is it possible to characterize solute transport behaviour parameters with only one available groundwater monitoring well or borehole? A so-called "push-pull" test may be one suitable method for aquifer testing with only one available access point. In a push-pull test a known amount of several solutes including a conservative tracer is injected into the aquifer ("push") and afterwards extracted ("pull"). The measured breakthrough curve during the pumping back phase can then be analysed. This method has already been used previously with various aims, also in the recent project (e.g. Hebig et al. 2011, Zeilfelder et al. 2012). However, different test setups produced different tracer breakthrough curves. As no systematic evaluation of this aquifer tracer test method was done so far, nothing is known about its repeatability. Does the injection and extraction rate influence the shape of the breakthrough curve? Which role plays the often applied "chaser", which is used to push the test solution out from the

  18. Quasi-static crack tip fields in rate-sensitive FCC single crystals

    Indian Academy of Sciences (India)

    gle crystals are now well-understood. On the other hand, there has been no investigation on the effect of strain rate sensitivity and loading rate on the stress and plastic slip distribution as well as constraint levels near a tip. Thus, the objective of this work is to examine the general structure of these distributions and the plastic ...

  19. Changes in vaginal breech delivery rates in a single large metropolitan area.

    LENUS (Irish Health Repository)

    Hehir, Mark P

    2012-06-01

    Vaginal breech delivery rates have been accepted widely to be in decline and the Term Breech Trial (TBT) has recommended delivery of a breech-presenting infant by elective cesarean section delivery. Our aim was to examine the rate of vaginal delivery of term breech pregnancies in the 8 years before and after the publication of the TBT.

  20. Evaluation of Railway Networks with Single Track Operation Using the UIC 406 Capacity Method

    DEFF Research Database (Denmark)

    Landex, Alex

    2009-01-01

    Many capacity analyses using the UIC 406 capacity method for double track lines have been carried out and presented international, but few capacity analyses applying the capacity method to single track lines have been presented. Therefore, the differences between capacity analyses of double track...

  1. Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction.

    Science.gov (United States)

    Chomczynski, P; Sacchi, N

    1987-04-01

    A new method of total RNA isolation by a single extraction with an acid guanidinium thiocyanate-phenol-chloroform mixture is described. The method provides a pure preparation of undegraded RNA in high yield and can be completed within 4 h. It is particularly useful for processing large numbers of samples and for isolation of RNA from minute quantities of cells or tissue samples.

  2. A new lattice hydrodynamic model based on control method considering the flux change rate and delay feedback signal

    Science.gov (United States)

    Qin, Shunda; Ge, Hongxia; Cheng, Rongjun

    2018-02-01

    In this paper, a new lattice hydrodynamic model is proposed by taking delay feedback and flux change rate effect into account in a single lane. The linear stability condition of the new model is derived by control theory. By using the nonlinear analysis method, the mKDV equation near the critical point is deduced to describe the traffic congestion. Numerical simulations are carried out to demonstrate the advantage of the new model in suppressing traffic jam with the consideration of flux change rate effect in delay feedback model.

  3. Superconducting Nanowire Single Photon Detectors for High-Data-Rate Deep-Space Optical Communication

    Data.gov (United States)

    National Aeronautics and Space Administration — High data rate deep space optical communication (DSOC) links for manned and unmanned space exploration have been identified by NASA as a critical future capability,...

  4. Interest Rate Demands and Television Viewing-Is a Single Exposure More Influential Than Routine Viewing?

    Science.gov (United States)

    Hetsroni, Amir; Reizer, Abira; Ben Zion, Uri

    2017-04-01

    This study examined the impact of media consumption, and particularly exposure to television, on decisions regarding interest rate demands. One hundred and fifty-four participants were randomly divided into two groups: in the manipulation group, participants were exposed to a news clip about an Iranian nuclear attack on Israel, whereas in the control group, the participants were not exposed to the film. Both groups filled a questionnaires regarding their interest rate requirements in different situations, their media conception behaviors, and demographic questionnaires. Frequent routine viewing increased the interest rate demands only among participants in the manipulation group, but the manipulation itself did not have a significant effect on interest rate demands. The results are explained in terms of cultivation theory.

  5. Method and apparatus for single-stepping coherence events in a multiprocessor system under software control

    Science.gov (United States)

    Blumrich, Matthias A.; Salapura, Valentina

    2010-11-02

    An apparatus and method are disclosed for single-stepping coherence events in a multiprocessor system under software control in order to monitor the behavior of a memory coherence mechanism. Single-stepping coherence events in a multiprocessor system is made possible by adding one or more step registers. By accessing these step registers, one or more coherence requests are processed by the multiprocessor system. The step registers determine if the snoop unit will operate by proceeding in a normal execution mode, or operate in a single-step mode.

  6. Single-grain cosmogenic Ne-21 concentrations in fluvial sediment reveal spatially variable erosion rates

    OpenAIRE

    Alexandru T. Codilean; P. Bishop; F. M. Stuart; T. B. Hoey; D. Fabel; S. P. H. T. Freeman;  

    2008-01-01

    We evaluated the hypothesis that the spatial variation in erosion in a catchment is refl ected in the distribution of the cosmogenic nuclide concentrations in sediments leaving the catchment. Using published data and four new 10Be measurements in fl uvial sediment collected from the outlets of small river catchments, we constrained the spatial variability of erosion rates in the Gaub River catchment in Namibia. We combined these catchment-averaged erosion rates, and the mean slope values with...

  7. Oversampling method to extract excitatory and inhibitory conductances from single-trial membrane potential recordings.

    Science.gov (United States)

    Bédard, Claude; Béhuret, Sebastien; Deleuze, Charlotte; Bal, Thierry; Destexhe, Alain

    2012-09-15

    Variations of excitatory and inhibitory conductances determine the membrane potential (V(m)) activity of neurons, as well as their spike responses, and are thus of primary importance. Methods to estimate these conductances require clamping the cell at several different levels of V(m), thus making it impossible to estimate conductances from "single trial" V(m) recordings. We present here a new method that allows extracting estimates of the full time course of excitatory and inhibitory conductances from single-trial V(m) recordings. This method is based on oversampling of the V(m). We test the method numerically using models of increasing complexity. Finally, the method is evaluated using controlled conductance injection in cortical neurons in vitro using the dynamic-clamp technique. This conductance extraction method should be very useful for future in vivo applications. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Neuroethologic differences in sleep deprivation induced by the single- and multiple-platform methods

    Directory of Open Access Journals (Sweden)

    R. Medeiros

    1998-05-01

    Full Text Available It has been proposed that the multiple-platform method (MP for desynchronized sleep (DS deprivation eliminates the stress induced by social isolation and by the restriction of locomotion in the single-platform (SP method. MP, however, induces a higher increase in plasma corticosterone and ACTH levels than SP. Since deprivation is of heuristic value to identify the functional role of this state of sleep, the objective of the present study was to determine the behavioral differences exhibited by rats during sleep deprivation induced by these two methods. All behavioral patterns exhibited by a group of 7 albino male Wistar rats submitted to 4 days of sleep deprivation by the MP method (15 platforms, spaced 150 mm apart and by 7 other rats submitted to sleep deprivation by the SP method were recorded in order to elaborate an ethogram. The behavioral patterns were quantitated in 10 replications by naive observers using other groups of 7 rats each submitted to the same deprivation schedule. Each quantification session lasted 35 min and the behavioral patterns presented by each rat over a period of 5 min were counted. The results obtained were: a rats submitted to the MP method changed platforms at a mean rate of 2.62 ± 1.17 platforms h-1 animal-1; b the number of episodes of noninteractive waking patterns for the MP animals was significantly higher than that for SP animals (1077 vs 768; c additional episodes of waking patterns (26.9 ± 18.9 episodes/session were promoted by social interaction in MP animals; d the cumulative number of sleep episodes observed in the MP test (311 was significantly lower (chi-square test, 1 d.f., P<0.05 than that observed in the SP test (534; e rats submitted to the MP test did not show the well-known increase in ambulatory activity observed after the end of the SP test; f comparison of 6 MP and 6 SP rats showed a significantly shorter latency to the onset of DS in MP rats (7.8 ± 4.3 and 29.0 ± 25.0 min, respectively

  9. Prediction of serotonin transporter promoter polymorphism genotypes from single nucleotide polymorphism arrays using machine learning methods.

    Science.gov (United States)

    Lu, Ake Tzu-Hui; Bakker, Steven; Janson, Esther; Cichon, Sven; Cantor, Rita M; Ophoff, Roel A

    2012-08-01

    The serotonin transporter gene (SLC6A4) and its promoter (5-HTTLPR) polymorphism have been the focus of a large number of association studies of behavioral traits and psychiatric disorders. However, large-scale genotyping of the polymorphism has been very difficult. We report the development and validation of a 5-HTTLPR genotype prediction model. The single nucleotide polymorphisms (SNPs) from the 2000 kb region surrounding 5-HTTLPR were used to construct a prediction model through a newly developed machine learning method, multicategory vertex discriminant analysis with 2147 individuals from the Northern Finnish Birth Cohort genotyped with the Illumina 370K SNP array and manually genotyped for 5-HTTLPR polymorphism. The prediction model was applied to SNP genotypes in a Dutch/German schizophrenia case-control sample of 3318 individuals to test the association of the polymorphism with schizophrenia. The prediction model of eight SNPs achieved a 92.4% accuracy rate and a 0.98±0.01 area under the receiving operating characteristic. Evidence for an association of the polymorphism with schizophrenia was observed (P=0.05, odds ratio=1.105). This prediction model provides an effective substitute of manually genotyped 5-HTTLPR alleles, providing a new approach for large scale association studies of this polymorphism.

  10. A Novel MPPT Control Method of Thermoelectric Power Generation with Single Sensor

    OpenAIRE

    Yamada, Hiroaki; Kimura, Koji; Hanamoto, Tsuyoshi; Ishiyama, Toshihiko; Sakaguchi, Tadashi; Takahashi, Tsuyoshi

    2013-01-01

    This paper proposes a novel Maximum Power Point Tracking (MPPT) control method of thermoelectric power generation for the constant load. This paper reveals the characteristics and the internal resistance of thermoelectric power module (TM). Analyzing the thermoelectric power generation system with boost chopper by state space averaging method, the output voltage and current of TM are estimated by with only single current sensor. The proposed method can seek without calculating the output powe...

  11. THE STANDARD SINGLE COST METHOD AND THE EFFICIENCY OF INDUSTRIAL COMPANIES’ MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Claudiu C. CONSTANTINESCU

    2008-12-01

    Full Text Available This article briefly describes the premises for the application of the standard direct cost calculation method in industry, the standard single cost calculation method, the stages of standard cost calculation per product and the calculation methods of standards per product. It also briefly underlines the possibilities of cost calculation and monitoring of deviation of the costs of raw materials and other materials as compared to the pre-established standard costs.

  12. Evaluation method of gas leakage rate from transportation casks of radioactive materials (gas leakage rates from scratches on O-ring surface)

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Li Ninghua; Asano, Ryoji; Kawa, Tsunemichi

    2004-01-01

    A sealing function is essential for transportation and/or storage casks of radioactive materials under both normal and accidental operating conditions in order to prevent radioactive materials from being released into the environment. In the safety analysis report, the release rate of radioactive materials into the environment is evaluated using the correlations specified in the ANSI N14.5, 1987. The purposes of the work are to reveal the underlying problems on the correlations specified in the ANSI N14.5 related to gas leakage rates from a scratch on O-ring surface and from multi-leak paths, to offer a data base to study the evaluation method of the leakage rate and to propose the evaluation method. In this paper, the following insights were obtained and clarified: 1. If a characteristic value of a leak path is defined as D 4 /a ('D' is the diameter and 'a' is the length), a scratch on the O-ring surface can be evaluated as a circular tube. 2. It is proper to use the width of O-ring groove on the flange as the leak path length for elastomer O-rings. 3. Gas leakage rates from multi leak paths of the transportation cask can be evaluated in the same manner as a single leak path if an effective D4/a is introduced. (author)

  13. Steady-State Crack Growth in Rate-Sensitive Single Crystals

    DEFF Research Database (Denmark)

    Juul, Kristian Jørgensen; Nielsen, Kim Lau; Niordson, Christian Frithiof

    2016-01-01

    The characteristics of the active plastic zone surrounding a crack growingin a single crystal (FCC, BCC, and HCP) at constant velocity is investigated for ModeI loading under plane strain assumptions. The framework builds upon a steady-state relation bringing the desired solution out in a frame...... translating with the crack tip. In the study, the shielding of the crack tip that follows from plastic slip is investigated by adopting the SSV-model. High resolution plots of the plastic zones are obtained and a detailed study confirms the existence of analytically determined velocity discontinuities from...

  14. A New Power Calculation Method for Single-Phase Grid-Connected Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2013-01-01

    A new method to calculate average active power and reactive power for single-phase systems is proposed in this paper. It can be used in different applications where the output active power and reactive power need to be calculated accurately and fast. For example, a grid-connected photovoltaic...... system in low voltage ride through operation mode requires a power feedback for the power control loop. Commonly, a Discrete Fourier Transform (DFT) based power calculation method can be adopted in such systems. However, the DFT method introduces at least a one-cycle time delay. The new power calculation...... method, which is based on the adaptive filtering technique, can achieve a faster response. The performance of the proposed method is verified by experiments and demonstrated in a 1 kW single-phase grid-connected system operating under different conditions.Experimental results show the effectiveness...

  15. An In Vitro Single-Primer Site-Directed Mutagenesis Method for Use in Biotechnology.

    Science.gov (United States)

    Huang, Yanchao; Zhang, Likui

    2017-01-01

    Site-directed mutagenesis is a powerful method to introduce mutation(s) into DNA sequences. A number of methods have been developed over the years with a main goal being to create a high number of mutant genes. The single-mutagenic primer method for site-directed mutagenesis is the most direct method that yields mutant genes in about 25-50 % of transformants in a robust, low-cost reaction. The supercompetent XL10-Gold bacteria used in the Stratagene protocol carry a phage, which may be a problem for some applications; however, in our single-mutagenic primer method the supercompetent bacteria are not needed. A thermostable DNA polymerase with high fidelity and processivity, such as Phusion DNA polymerase, is required for our optimized procedure to avoid extra mutation(s) and enhance mutagenic efficiency.

  16. Accelerating finite-rate chemical kinetics with coprocessors: Comparing vectorization methods on GPUs, MICs, and CPUs

    Science.gov (United States)

    Stone, Christopher P.; Alferman, Andrew T.; Niemeyer, Kyle E.

    2018-05-01

    Accurate and efficient methods for solving stiff ordinary differential equations (ODEs) are a critical component of turbulent combustion simulations with finite-rate chemistry. The ODEs governing the chemical kinetics at each mesh point are decoupled by operator-splitting allowing each to be solved concurrently. An efficient ODE solver must then take into account the available thread and instruction-level parallelism of the underlying hardware, especially on many-core coprocessors, as well as the numerical efficiency. A stiff Rosenbrock and a nonstiff Runge-Kutta ODE solver are both implemented using the single instruction, multiple thread (SIMT) and single instruction, multiple data (SIMD) paradigms within OpenCL. Both methods solve multiple ODEs concurrently within the same instruction stream. The performance of these parallel implementations was measured on three chemical kinetic models of increasing size across several multicore and many-core platforms. Two separate benchmarks were conducted to clearly determine any performance advantage offered by either method. The first benchmark measured the run-time of evaluating the right-hand-side source terms in parallel and the second benchmark integrated a series of constant-pressure, homogeneous reactors using the Rosenbrock and Runge-Kutta solvers. The right-hand-side evaluations with SIMD parallelism on the host multicore Xeon CPU and many-core Xeon Phi co-processor performed approximately three times faster than the baseline multithreaded C++ code. The SIMT parallel model on the host and Phi was 13%-35% slower than the baseline while the SIMT model on the NVIDIA Kepler GPU provided approximately the same performance as the SIMD model on the Phi. The runtimes for both ODE solvers decreased significantly with the SIMD implementations on the host CPU (2.5-2.7 ×) and Xeon Phi coprocessor (4.7-4.9 ×) compared to the baseline parallel code. The SIMT implementations on the GPU ran 1.5-1.6 times faster than the baseline

  17. Multicomponent Treatment of Rapid Naming, Reading Rate, and Visual Attention in Single and Double Deficit Dyslexics

    Science.gov (United States)

    Johnson, Kary A.

    2013-01-01

    While the relationship between rapid automatic naming (RAN) deficiencies and dyslexia (reading disability) is well developed and supported in the behavioral and medical research literature to date, direct treatment of the specific RAN deficiency in addition to subsequently poor reading outcomes in the lexical skill of reading rate and the…

  18. Heart Rate Variability Biofeedback Stress Relief Program for Depression A Replicated Single-Subject Design

    NARCIS (Netherlands)

    Hartogs, Bregje M. A.; Bartels-Velthuis, Agna A.; Van der Ploeg, Karen; Bos, Elske H.

    2017-01-01

    Background: Depressive disorders often have a chronic course and the efficacy of evidence-based treatments may be overestimated. Objective: To examine the effectiveness of the Heart Rate Variability Stress Reduction Program (SRP) as a supplement to standard treatment in patients with depressive

  19. Modified Regression Rate Formula of PMMA Combustion by a Single Plane Impinging Jet

    Directory of Open Access Journals (Sweden)

    Tsuneyoshi Matsuoka

    2017-01-01

    Full Text Available A modified regression rate formula for the uppermost stage of CAMUI-type hybrid rocket motor is proposed in this study. Assuming a quasi-steady, one-dimensional, an energy balance against a control volume near the fuel surface is considered. Accordingly, the regression rate formula which can calculate the local regression rate by the quenching distance between the flame and the regression surface is derived. An experimental setup which simulates the combustion phenomenon involved in the uppermost stage of a CAMUI-type hybrid rocket motor was constructed and the burning tests with various flow velocities and impinging distances were performed. A PMMA slab of 20 mm height, 60 mm width, and 20 mm thickness was chosen as a sample specimen and pure oxygen and O2/N2 mixture (50/50 vol.% were employed as the oxidizers. The time-averaged regression rate along the fuel surface was measured by a laser displacement sensor. The quenching distance during the combustion event was also identified from the observation. The comparison between the purely experimental and calculated values showed good agreement, although a large systematic error was expected due to the difficulty in accurately identifying the quenching distance.

  20. A single pacemaker can produce different rates of reentrainment in different overt rhythms

    NARCIS (Netherlands)

    Daan, Serge; Beersma, Domien G.M.

    1992-01-01

    Using a simple Van der Pol oscillator, we show that periodic events triggered by different states of the oscillator can reentrain at different rates following a phase shift of the Zeitgeber. Such differences can emerge due to waveform distortion during reentrainment, due to masking and due to

  1. Magnet-related injury rates in children: a single hospital experience.

    Science.gov (United States)

    Agbo, Chioma; Lee, Lois; Chiang, Vincent; Landscahft, Assaf; Kimia, Tomer; Monuteaux, Michael C; Kimia, Amir A

    2013-07-01

    The ingestion of multiple magnets simultaneously or the placement of magnets in both nares can lead to serious injury resulting from the attraction of the magnets across the tissues. The impact of mandatory standards for toys containing magnets has not been thoroughly investigated. The aim of the present study was to describe the emergency department (ED) visit rate for magnet-related injuries. We performed a retrospective study of children evaluated for magnet-related injuries from 1995 to 2012 in an urban tertiary care pediatric ED. We identified cases using a computerized text-search methodology followed by manual chart review. We included children evaluated for magnet ingestion or impaction in the ears, nose, vagina, or rectum. We assessed the type and number of magnets as well as management and required interventions. A Poisson regression model was used to analyze rates of injury over time. We identified 112 cases of magnet injuries. The median patient age was 6 years (IQR 3.5, 10), and 54% were male. Compared to before 2006, the rate for all magnet-related injuries in 2007-2012 (incidence rate ratio 3.44; 95% confidence interval 2.3-5.11) as well as multiple magnet-related injuries (incidence rate ratio 7.54; 95% confidence interval 3.51-16.19) increased. Swallowed magnets accounted for 86% of the injuries. Thirteen patients had endoscopy performed for magnet removal (12%), and 4 (4%) had a surgical intervention. Magnets from toys account for the majority of the injuries. The number of ED visits for magnet-related injuries in children may be rising and are underreported, with an increase in the proportion of multiple magnets involvement. In our case series, mandatory standard for toys had no mitigating effect.

  2. Presentation of an in-operation failure rate calculation method from an event data bank

    International Nuclear Information System (INIS)

    Aupied, J.R.; Piepszownik, L.

    1987-01-01

    This paper shortly describes a calculation method of a component failure rate during operation, from an event data bank. This method is validated by comparing the results obtained with those issued from a reliability data bank. The main interest of this method is to permit an enrichment of reliability data. Further development required needs to take account of ageing effects in this method. (orig.)

  3. VET Program Completion Rates: An Evaluation of the Current Method. Occasional Paper

    Science.gov (United States)

    National Centre for Vocational Education Research (NCVER), 2016

    2016-01-01

    This work asks one simple question: "how reliable is the method used by the National Centre for Vocational Education Research (NCVER) to estimate projected rates of VET program completion?" In other words, how well do early projections align with actual completion rates some years later? Completion rates are simple to calculate with a…

  4. Trends in Hanging and Firearm Suicide Rates in Australia: Substitution of Method?

    Science.gov (United States)

    De Leo, Diego; Dwyer, Jonathan; Firman, David; Neulinger, Kerryn

    2003-01-01

    This study examined the increase in the rate of suicide by hanging and an apparently simultaneous decrease in the rate of suicide by firearm as hypothetical evidence that Australian males have substituted one method of suicide for another. Individual suicide method choice may be related to independent changes in the social acceptability of each…

  5. Phase-coexistence simulations of fluid mixtures by the Markov Chain Monte Carlo method using single-particle models

    KAUST Repository

    Li, Jun

    2013-09-01

    We present a single-particle Lennard-Jones (L-J) model for CO2 and N2. Simplified L-J models for other small polyatomic molecules can be obtained following the methodology described herein. The phase-coexistence diagrams of single-component systems computed using the proposed single-particle models for CO2 and N2 agree well with experimental data over a wide range of temperatures. These diagrams are computed using the Markov Chain Monte Carlo method based on the Gibbs-NVT ensemble. This good agreement validates the proposed simplified models. That is, with properly selected parameters, the single-particle models have similar accuracy in predicting gas-phase properties as more complex, state-of-the-art molecular models. To further test these single-particle models, three binary mixtures of CH4, CO2 and N2 are studied using a Gibbs-NPT ensemble. These results are compared against experimental data over a wide range of pressures. The single-particle model has similar accuracy in the gas phase as traditional models although its deviation in the liquid phase is greater. Since the single-particle model reduces the particle number and avoids the time-consuming Ewald summation used to evaluate Coulomb interactions, the proposed model improves the computational efficiency significantly, particularly in the case of high liquid density where the acceptance rate of the particle-swap trial move increases. We compare, at constant temperature and pressure, the Gibbs-NPT and Gibbs-NVT ensembles to analyze their performance differences and results consistency. As theoretically predicted, the agreement between the simulations implies that Gibbs-NVT can be used to validate Gibbs-NPT predictions when experimental data is not available. © 2013 Elsevier Inc.

  6. The strain rate effect on the buckling of single-layer MoS2.

    Science.gov (United States)

    Jiang, Jin-Wu

    2015-01-15

    The Euler buckling theory states that the buckling critical strain is an inverse quadratic function of the length for a thin plate in the static compression process. However, the suitability of this theory in the dynamical process is unclear, so we perform molecular dynamics simulations to examine the applicability of the Euler buckling theory for the fast compression of the single-layer MoS2. We find that the Euler buckling theory is not applicable in such dynamical process, as the buckling critical strain becomes a length-independent constant in the buckled system with many ripples. However, the Euler buckling theory can be resumed in the dynamical process after restricting the theory to an individual ripple in the buckled structure.

  7. Oncologic results, functional outcomes, and complication rates of transperitoneal robotic assisted radical prostatectomy: single centre's experience.

    Science.gov (United States)

    Ihsan-Tasci, A; Simsek, A; Dogukan-Torer, M B; Sokmen, D; Sahin, S; Bitkin, A; Tugcu, V

    2015-03-01

    We report the operative details and short term oncologic and functional outcome of the first 334 Robotic-assisted radical prostatectomy experiences for organ confined prostate cancer From August 2009 to December 2012, details of 334 consecutive patients were retrospectively analyzed. The analyzed parameters included: preoperative, per-operative characteristics, postoperative minor and major complications, positive surgical margin continence, potency, and biochemical progression at the follow-up period. The classical extrafascial, interfascial, intrafascial and fascia sparing radical prostatectomy were performed in 31, 41, 200, and 62 cases, respectively. The mean operation time was 213.8±90.1minutes, and the mean estimated blood loss was 116.1±58.9cc during operation. A nerve-sparing procedure was performed bilaterally in 198 (59.3%) cases and unilaterally in 126 (37.7%) cases. The catheter was removed on postoperative day 9, 1±1.9. Surgical margin was positive in 36 (10.7%) patients. The overall, pT2, pT3a and pT3b PSM rates were 8 (2.4%), 12 (3.6%), 16 (4.8%) respectively and PSM and BCR rates were not statistically different among four approach (P>.05). At the follow-up period, the continence rates were 74.4%, 80.4%, 80.5%, and 96.7% (P.05), in classic extrafascial, interfascial, intrafascial, and fascia sparing intrafascial prostatectomy, respectively. RARP is a safe and feasible technique in treatment of localized prostate cancer. Fascia sparing approach has better continence rate. This results need to be supported by new prospective, randomized studies. Copyright © 2013 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Single interval longwave radiation scheme based on the net exchanged rate decomposition with bracketing

    Czech Academy of Sciences Publication Activity Database

    Geleyn, J.- F.; Mašek, Jan; Brožková, Radmila; Kuma, P.; Degrauwe, D.; Hello, G.; Pristov, N.

    2017-01-01

    Roč. 143, č. 704 (2017), s. 1313-1335 ISSN 0035-9009 R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:86652079 Keywords : numerical weather prediction * climate models * clouds * parameterization * atmospheres * formulation * absorption * scattering * accurate * database * longwave radiative transfer * broadband approach * idealized optical paths * net exchanged rate decomposition * bracketing * selective intermittency Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 3.444, year: 2016

  9. A power supply error correction method for single-ended digital audio class D amplifiers

    Science.gov (United States)

    Yu, Zeqi; Wang, Fengqin; Fan, Yangyu

    2016-12-01

    In single-ended digital audio class D amplifiers (CDAs), the errors caused by power supply noise in the power stages degrade the output performance seriously. In this article, a novel power supply error correction method is proposed. This method introduces the power supply noise of the power stage into the digital signal processing block and builds a power supply error corrector between the interpolation filter and the uniform-sampling pulse width modulation (UPWM) lineariser to pre-correct the power supply error in the single-ended digital audio CDA. The theoretical analysis and implementation of the method are also presented. To verify the effectiveness of the method, a two-channel single-ended digital audio CDA with different power supply error correction methods is designed, simulated, implemented and tested. The simulation and test results obtained show that the method can greatly reduce the error caused by the power supply noise with low hardware cost, and that the CDA with the proposed method can achieve a total harmonic distortion + noise (THD + N) of 0.058% for a -3 dBFS, 1 kHz input when a 55 V linear unregulated direct current (DC) power supply (with the -51 dBFS, 100 Hz power supply noise) is used in the power stages.

  10. Protein structural model selection by combining consensus and single scoring methods.

    Directory of Open Access Journals (Sweden)

    Zhiquan He

    Full Text Available Quality assessment (QA for predicted protein structural models is an important and challenging research problem in protein structure prediction. Consensus Global Distance Test (CGDT methods assess each decoy (predicted structural model based on its structural similarity to all others in a decoy set and has been proved to work well when good decoys are in a majority cluster. Scoring functions evaluate each single decoy based on its structural properties. Both methods have their merits and limitations. In this paper, we present a novel method called PWCom, which consists of two neural networks sequentially to combine CGDT and single model scoring methods such as RW, DDFire and OPUS-Ca. Specifically, for every pair of decoys, the difference of the corresponding feature vectors is input to the first neural network which enables one to predict whether the decoy-pair are significantly different in terms of their GDT scores to the native. If yes, the second neural network is used to decide which one of the two is closer to the native structure. The quality score for each decoy in the pool is based on the number of winning times during the pairwise comparisons. Test results on three benchmark datasets from different model generation methods showed that PWCom significantly improves over consensus GDT and single scoring methods. The QA server (MUFOLD-Server applying this method in CASP 10 QA category was ranked the second place in terms of Pearson and Spearman correlation performance.

  11. Children and youth with disabilities: innovative methods for single qualitative interviews.

    Science.gov (United States)

    Teachman, Gail; Gibson, Barbara E

    2013-02-01

    There is a paucity of explicit literature outlining methods for single-interview studies with children, and almost none have focused on engaging children with disabilities. Drawing from a pilot study, we address these gaps by describing innovative techniques, strategies, and methods for engaging children and youth with disabilities in a single qualitative interview. In the study, we explored the beliefs, assumptions, and experiences of children and youth with cerebral palsy and their parents regarding the importance of walking. We describe three key aspects of our child-interview methodological approach: collaboration with parents, a toolkit of customizable interview techniques, and strategies to consider the power differential inherent in child-researcher interactions. Examples from our research illustrate what worked well and what was less successful. Researchers can optimize single interviews with children with disabilities by collaborating with family members and by preparing a toolkit of customizable interview techniques.

  12. Methods of preparing and using single chain anti-tumor antibodies

    Science.gov (United States)

    Cheung, Nai-Kong; Guo, Hong-Fen

    2010-02-23

    This invention provides a method for identifying cells expressing a target single chain antibody (scFv) directed against a target antigen from a collection of cells that includes cells that do not express the target scFv, comprising the step of combining the collection of cells with an anti-idiotype directed to an antibody specific for the target antigen and detecting interaction, if any, of the anti-idiotype with the cells, wherein the occurrence of an interaction identifies the cell as one which expresses the target scFv. This invention also provides a method for making a single chain antibody (scFv) directed against an antigen, wherein the selection of clones is made based upon interaction of those clones with an appropriate anti-idiotype, and heretofore inaccessible scFv so made. This invention provides the above methods or any combination thereof. Finally, this invention provides various uses of these methods.

  13. A NEW FRACTIONAL MODEL OF SINGLE DEGREE OF FREEDOM SYSTEM, BY USING GENERALIZED DIFFERENTIAL TRANSFORM METHOD

    Directory of Open Access Journals (Sweden)

    HASHEM SABERI NAJAFI

    2016-07-01

    Full Text Available Generalized differential transform method (GDTM is a powerful method to solve the fractional differential equations. In this paper, a new fractional model for systems with single degree of freedom (SDOF is presented, by using the GDTM. The advantage of this method compared with some other numerical methods has been shown. The analysis of new approximations, damping and acceleration of systems are also described. Finally, by reducing damping and analysis of the errors, in one of the fractional cases, we have shown that in addition to having a suitable solution for the displacement close to the exact one, the system enjoys acceleration once crossing the equilibrium point.

  14. Independent screening for single-index hazard rate models with ultrahigh dimensional features

    DEFF Research Database (Denmark)

    Gorst-Rasmussen, Anders; Scheike, Thomas

    2013-01-01

    on performance. An iterative variant of the method is also described which combines screening with penalized regression to handle more complex feature covariance structures. The methodology is evaluated through simulation studies and through application to a real gene expression data set.......In data sets with many more features than observations, independent screening based on all univariate regression models leads to a computationally convenient variable selection method. Recent efforts have shown that, in the case of generalized linear models, independent screening may suffice...... to capture all relevant features with high probability, even in ultrahigh dimension. It is unclear whether this formal sure screening property is attainable when the response is a right-censored survival time. We propose a computationally very efficient independent screening method for survival data which...

  15. Hybrid Control Method for a Single Phase PFC using a Low Cost Microcontroller

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Nielsen, Nils; Wolf, Christian

    2005-01-01

    This paper presents a hybrid control method for single phase boost PFCs. The high bandwidth current loop is analog while the voltage loop is implemented in an 8-bit microcontroller. The design focuses on minimizing the number of calculations done in the microcontroller. A 1kW prototype has been...

  16. A MISO-ARX-Based Method for Single-Trial Evoked Potential Extraction

    Directory of Open Access Journals (Sweden)

    Nannan Yu

    2017-01-01

    Full Text Available In this paper, we propose a novel method for solving the single-trial evoked potential (EP estimation problem. In this method, the single-trial EP is considered as a complex containing many components, which may originate from different functional brain sites; these components can be distinguished according to their respective latencies and amplitudes and are extracted simultaneously by multiple-input single-output autoregressive modeling with exogenous input (MISO-ARX. The extraction process is performed in three stages: first, we use a reference EP as a template and decompose it into a set of components, which serve as subtemplates for the remaining steps. Then, a dictionary is constructed with these subtemplates, and EPs are preliminarily extracted by sparse coding in order to roughly estimate the latency of each component. Finally, the single-trial measurement is parametrically modeled by MISO-ARX while characterizing spontaneous electroencephalographic activity as an autoregression model driven by white noise and with each component of the EP modeled by autoregressive-moving-average filtering of the subtemplates. Once optimized, all components of the EP can be extracted. Compared with ARX, our method has greater tracking capabilities of specific components of the EP complex as each component is modeled individually in MISO-ARX. We provide exhaustive experimental results to show the effectiveness and feasibility of our method.

  17. Using the Image Analysis Method for Describing Soil Detachment by a Single Water Drop Impact

    Directory of Open Access Journals (Sweden)

    Magdalena Ryżak

    2012-08-01

    Full Text Available The aim of the present work was to develop a method based on image analysis for describing soil detachment caused by the impact of a single water drop. The method consisted of recording tracks made by splashed particles on blotting paper under an optical microscope. The analysis facilitated division of the recorded particle tracks on the paper into drops, “comets” and single particles. Additionally, the following relationships were determined: (i the distances of splash; (ii the surface areas of splash tracks into relation to distance; (iii the surface areas of the solid phase transported over a given distance; and (iv the ratio of the solid phase to the splash track area in relation to distance. Furthermore, the proposed method allowed estimation of the weight of soil transported by a single water drop splash in relation to the distance of the water drop impact. It was concluded that the method of image analysis of splashed particles facilitated analysing the results at very low water drop energy and generated by single water drops.

  18. A Generic Topology Derivation Method for Single-phase Converters with Active Capacitive DC-links

    DEFF Research Database (Denmark)

    Wang, Haoran; Wang, Huai; Zhu, Guorong

    2016-01-01

    capacitive DCDC- link solutions, but important aspects of the topology assess-ment, such as the total energy storage, overall capacitive energy buffer ratio, cost, and reliability are still not available. This paper proposes a generic topology derivation method of single-phase power converters...

  19. Iterative method of analysis of single queue, multi-server with limited ...

    African Journals Online (AJOL)

    In this paper, analysis of single queue, multi-server with limited system capacity under first come first served discipline was carried out using iterative method. The arrivals of customers and service times of customers are assumed poisson and exponential distributions respectively. This queuing model is an extension of ...

  20. Optical characteristics of ZnO single crystal grown by the hydrothermal method

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G. Z.; Yin, J. G., E-mail: gzhchen@siom.ac.cn, E-mail: yjg@siom.ac.cn; Zhang, L. H.; Zhang, P. X.; Wang, X. Y.; Liu, Y. C. [Chinese Academy of Sciences, Key Laboratory of High Power Laser Materials, Shanghai Institute of Optics and Fine Mechanics (China); Zhang, C. L. [Guilin Research Institute of Geology for Mineral Resources (China); Gu, S. L. [Nanjing University, Department of Physics (China); Hang, Y., E-mail: yhang@siom.ac.cn [Chinese Academy of Sciences, Key Laboratory of High Power Laser Materials, Shanghai Institute of Optics and Fine Mechanics (China)

    2015-12-15

    ZnO single crystals have been grown by the hydrothermal method. Raman scattering and Photoluminescence spectroscopy (PL) have been used to study samples of ZnO that were unannealed or annealed in different ambient gases. It is suggested that the green emission may originate from defects related to copper in our samples.

  1. A Method for Robust Strategic Railway Dispatch Applied to a Single Track Line

    DEFF Research Database (Denmark)

    Harrod, Steven

    2013-01-01

    A method is presented for global optimization of a dispatch plan assuming perfect information over a given time horizon. An example problem is solved for the North American case of a single dominant high-speed train sharing a network with a majority flow of slower trains. Initial dispatch priority...

  2. See me, feel me: methods to concurrently visualize and manipulate single DNA molecules and associated proteins

    NARCIS (Netherlands)

    van Mameren, J.; Peterman, E.J.G.; Wuite, G.J.L.

    2008-01-01

    Direct visualization of DNA and proteins allows researchers to investigate DNA-protein interactions with great detail. Much progress has been made in this area as a result of increasingly sensitive single-molecule fluorescence techniques. At the same time, methods that control the conformation of

  3. A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters

    DEFF Research Database (Denmark)

    Monfared, Mohammad; Golestan, Saeed; Guerrero, Josep M.

    2013-01-01

    This paper deals with the design of a novel method in the synchronous reference frame (SRF) to extract the reference compensating current for single-phase shunt active power filters (APFs). Unlike previous works in the SRF, the proposed method has an innovative feature that it does not need the f...... the excellent performance of the suggested approach. Theoretical evaluations are confirmed by experimental results....

  4. Accuracy of single count methods of WL determination for open-pit uranium mines

    International Nuclear Information System (INIS)

    Solomon, S.B.; Kennedy, K. N.

    1983-01-01

    A study of single count methods of WL determination was made using a database respresentative of Australian open pit uranium mine conditions. The aim of the study was to check the existence of the optimum time delay coresponding to the Rolle method, to determine the accuracy of the conversion factor for Australian conditions and to examine any systematic use of data bases of representative radon daughter concentration

  5. Single Tracking Location Methods Suppress Speckle Noise in Shear Wave Velocity Estimation

    OpenAIRE

    Elegbe, Etana C.; McAleavey, Stephen A.

    2013-01-01

    In ultrasound-based elastography methods, the estimation of shear wave velocity typically involves the tracking of speckle motion due to an applied force. The errors in the estimates of tissue displacement, and thus shear wave velocity, are generally attributed to electronic noise and decorrelation due to physical processes. We present our preliminary findings on another source of error, namely, speckle-induced bias in phase estimation. We find that methods that involve tracking in a single l...

  6. Characterization of strained InGaAs single quantum well structures by ion beam methods

    International Nuclear Information System (INIS)

    Yu, K.M.; Chan, K.T.

    1990-01-01

    We have investigated strained InGaAs single quantum well structures using MeV ion beam methods. The structural properties of these structures, including composition and well size, have been studied. It has been found that the composition obtained by Rutherford backscattering spectrometry and particle-induced x-ray emission techniques agrees very well with that obtained by the ion channeling method

  7. Organometallic halide perovskite single crystals having low deffect density and methods of preparation thereof

    KAUST Repository

    Bakr, Osman M.

    2016-02-18

    The present disclosure presents a method of making a single crystal organometallic halide perovskites, with the formula: AMX3, wherein A is an organic cation, M is selected from the group consisting of: Pb, Sn, Cu, Ni, Co, Fe, Mn, Pd, Cd, Ge, and Eu, and X is a halide. The method comprises the use of two reservoirs containing different precursors and allowing the vapor diffusion from one reservoir to the other one. A solar cell comprising said crystal is also disclosed.

  8. Experimental study on new monitoring method of radon release rate from uranium tailings

    CERN Document Server

    Fu Jin; HanYaozHao; He Wen Xing; Zhang Biao

    2002-01-01

    Two new monitoring methods of radon release rate from uranium tailings are introduced. They are the active carbon absorption and gamma energy spectrum method. The instrument and sampler of active carbon absorption is presented with the manufacture, function, performance and calibration, the conditional test of the method and its measuring contrast to that of local static method. One-year continuous in-site monitoring of radon release rate of uranium tailings was done. The annual change regularity of radon release rate from uranium tailings was observed. The optimum season and condition of monitoring the annual average radon release rate are summarized. The parameter monitoring, calculating method and experimentation of gamma energy spectrum method is discussed

  9. A method for projecting age-specific mortality rates for certain causes of death

    International Nuclear Information System (INIS)

    Leggett, R.W.; Crawford, D.J.

    1981-01-01

    A method is presented for projecting mortality rates for certain causes on the basis of observed rates during past years. This method arose from a study of trends in age-specific mortality rates for respiratory cancers, and for heuristic purposes it is shown how the method can be developed from certain theories of cancer induction. However, the method is applicable in the more common situation in which the underlying physical processes cannot be modeled with any confidence but the mortality rates are approximable over short time intervals by functions of the form a exp(bt), where b may vary in a continuous, predictable fashion as the time interval is varied. It appears from applications to historical data that this projection method is in some cases a substantial improvement over conventional curve-fitting methods and often uncovers trends which are not from observed data

  10. HydroCoils, occlusion rates, and outcomes: a large single-center study.

    LENUS (Irish Health Repository)

    O'Hare, A M

    2010-11-01

    The HydroCoil is an expansile hydrogel coil designed to produce a greater degree of volumetric packing within cerebral aneurysms when compared with bare platinum coils. This increased packing is, in turn, believed to decrease the risk of recurrence within aneurysms and hence the risk of their rupture in the long term. The aim of this work was to assess whether the use of HydroCoils and the proportion of HydroCoil used have any influence on the subsequent occlusion and recurrence rates of treated aneurysms.

  11. In-target rare nuclei production rates with EURISOL single-stage configuration

    CERN Document Server

    Chabod, S P; Ene, D; Doré, D; Blideanu, V; David, J.-Ch; Ridikas, D

    2010-01-01

    We conducted calculations of exotic nuclei production rates for 320 configurations of EURISOL (European Isotope Separation On-Line Radioactive Ion Beam Facility) direct spallation targets. The nuclei yields were evaluated using neutron generation-transport codes, completed with evolution calculations to account for nuclei decays and low energy neutron interactions. The yields were optimized for 11 selected elements (Li, Be, Ne, Mg, Ar, Ni, Ga, Kr, Sn, Hg, Fr) and 23 of their isotopes, as function of the target compositions and geometries as well as the incident proton beam energies. For the considered elements, we evaluated the yield distributions as functions of the charge and mass numbers using two different spallation models.

  12. Blastocyst utilization rates after continuous culture in two commercial single-step media: a prospective randomized study with sibling oocytes.

    Science.gov (United States)

    Sfontouris, Ioannis A; Kolibianakis, Efstratios M; Lainas, George T; Venetis, Christos A; Petsas, George K; Tarlatzis, Basil C; Lainas, Tryfon G

    2017-10-01

    The aim of this study is to determine whether blastocyst utilization rates are different after continuous culture in two different commercial single-step media. This is a paired randomized controlled trial with sibling oocytes conducted in infertility patients, aged ≤40 years with ≥10 oocytes retrieved assigned to blastocyst culture and transfer. Retrieved oocytes were randomly allocated to continuous culture in either Sage one-step medium (Origio) or Continuous Single Culture (CSC) medium (Irvine Scientific) without medium renewal up to day 5 post oocyte retrieval. Main outcome measure was the proportion of embryos suitable for clinical use (utilization rate). A total of 502 oocytes from 33 women were randomly allocated to continuous culture in either Sage one-step medium (n = 250) or CSC medium (n = 252). Fertilization was performed by either in vitro fertilization or intracytoplasmic sperm injection, and embryo transfers were performed on day 5. Two patients had all blastocysts frozen due to the occurrence of severe ovarian hyperstimulation syndrome. Fertilization and cleavage rates, as well as embryo quality on day 3, were similar in the two media. Blastocyst utilization rates (%, 95% CI) [55.4% (46.4-64.1) vs 54.7% (44.9-64.6), p = 0.717], blastocyst formation rates [53.6% (44.6-62.5) vs 51.9 (42.2-61.6), p = 0.755], and proportion of good quality blastocysts [36.8% (28.1-45.4) vs 36.1% (27.2-45.0), p = 0.850] were similar in Sage one-step and CSC media, respectively. Continuous culture of embryos in Sage one-step and CSC media is associated with similar blastocyst development and utilization rates. Both single-step media appear to provide adequate support during in vitro preimplantation embryo development. Whether these observations are also valid for other continuous single medium protocols remains to be determined. NCT02302638.

  13. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lin, Yashen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Dhople, Sairaj [University of Minnesota

    2017-09-28

    From the inception of power systems, synchronous machines have acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, power electronics interfaces are playing a growing role as they are the primary interface for several types of renewable energy sources and storage technologies. As the role of power electronics in systems continues to grow, it is crucial to investigate the properties of bulk power systems in low inertia settings. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. Furthermore, the inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings and, hence, differing levels of inertia. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the interaction between the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

  14. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lin, Yashen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Dhople, Sairaj [University of Minnesota

    2017-11-16

    Synchronous machines have traditionally acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, with the increased integration of distributed renewable resources and energy-storage technologies, there is a need to systematically acknowledge the dynamics of power-electronics inverters - the primary energy-conversion interface in such systems - in all aspects of modeling, analysis, and control of the bulk power network. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. The inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

  15. Single-mode Rayleigh-Taylor growth-rate measurements with the OMEGA laser system

    International Nuclear Information System (INIS)

    Knauer, J.P.; Verdon, C.P.; Meyerhofer, D.D.; Boehly, T.R.; Bradley, D.K.; Smalyuk, V.A.; Ofer, D.; McKenty, P.W.; Glendinning, S.G.; Kalantar, D.H.; Watt, R.G.; Gobby, P.L.; Willi, O.; Taylor, R.J.

    1997-01-01

    The results from a series of single-mode Rayleigh-Taylor (RT) instability growth experiments performed on the OMEGA laser system using planar targets are reported. Planar targets with imposed mass perturbations were accelerated using five to six 351-nm laser beams overlapped with total intensities up to 2.5x10 14 W/cm 2 . Experiments were performed with both 3-ns ramp and 3-ns flat-topped temporal pulse shapes. The use of distributed phase plates and smoothing by spectral dispersion resulted in a laser-irradiation nonuniformity of 4%endash 7% over a 600-μm-diam region defined by the 90% intensity contour. The temporal growth of the modulation in optical depth was measured using through-foil radiography and was detected with an x-ray framing camera for CH targets with and without a foam buffer. The growth of both 31-μm and 60-μm wavelength perturbations was found to be in good agreement with ORCHID simulations when the experimental details, including noise, were included. The addition of a 30-mg/cc, 100-μm-thick polystyrene foam buffer layer resulted in reduced growth of the 31-μm perturbation and essentially unchanged growth for the 60-μm case when compared to targets without foam. copyright 1997 American Institute of Physics

  16. CLARO: an ASIC for high rate single photon counting with multi-anode photomultipliers

    Science.gov (United States)

    Baszczyk, M.; Carniti, P.; Cassina, L.; Cotta Ramusino, A.; Dorosz, P.; Fiorini, M.; Gotti, C.; Kucewicz, W.; Malaguti, R.; Pessina, G.

    2017-08-01

    The CLARO is a radiation-hard 8-channel ASIC designed for single photon counting with multi-anode photomultiplier tubes. Each channel outputs a digital pulse when the input signal from the photomultiplier crosses a configurable threshold. The fast return to baseline, typically within 25 ns, and below 50 ns in all conditions, allows to count up to 107 hits/s on each channel, with a power consumption of about 1 mW per channel. The ASIC presented here is a much improved version of the first 4-channel prototype. The threshold can be precisely set in a wide range, between 30 ke- (5 fC) and 16 Me- (2.6 pC). The noise of the amplifier with a 10 pF input capacitance is 3.5 ke- (0.6 fC) RMS. All settings are stored in a 128-bit configuration and status register, protected against soft errors with triple modular redundancy. The paper describes the design of the ASIC at transistor-level, and demonstrates its performance on the test bench.

  17. Explicit Singly Diagonally Implicit Runge-Kutta Methods and Adaptive Stepsize Control for Reservoir Simulation

    DEFF Research Database (Denmark)

    Völcker, Carsten; Jørgensen, John Bagterp; Thomsen, Per Grove

    2010-01-01

    The implicit Euler method, normally refered to as the fully implicit (FIM) method, and the implicit pressure explicit saturation (IMPES) method are the traditional choices for temporal discretization in reservoir simulation. The FIM method offers unconditionally stability in the sense of discrete....... Current reservoir simulators apply timestepping algorithms that are based on safeguarded heuristics, and can neither guarantee convergence in the underlying equation solver, nor provide estimates of the relations between convergence, integration error and stepsizes. We establish predictive stepsize...... control applied to high order methods for temporal discretization in reservoir simulation. The family of Runge-Kutta methods is presented and in particular the explicit singly diagonally implicit Runge-Kutta (ESDIRK) method with an embedded error estimate is described. A predictive stepsize adjustment...

  18. Gallium arsenide single crystal solar cell structure and method of making

    Science.gov (United States)

    Stirn, Richard J. (Inventor)

    1983-01-01

    A production method and structure for a thin-film GaAs crystal for a solar cell on a single-crystal silicon substrate (10) comprising the steps of growing a single-crystal interlayer (12) of material having a closer match in lattice and thermal expansion with single-crystal GaAs than the single-crystal silicon of the substrate, and epitaxially growing a single-crystal film (14) on the interlayer. The material of the interlayer may be germanium or graded germanium-silicon alloy, with low germanium content at the silicon substrate interface, and high germanium content at the upper surface. The surface of the interface layer (12) is annealed for recrystallization by a pulsed beam of energy (laser or electron) prior to growing the interlayer. The solar cell structure may be grown as a single-crystal n.sup.+ /p shallow homojunction film or as a p/n or n/p junction film. A Ga(Al)AS heteroface film may be grown over the GaAs film.

  19. A modified single-cell electroporation method for molecule delivery into a motile protist, Euglena gracilis.

    Science.gov (United States)

    Ohmachi, Masashi; Fujiwara, Yoshie; Muramatsu, Shuki; Yamada, Koji; Iwata, Osamu; Suzuki, Kengo; Wang, Dan Ohtan

    2016-11-01

    Single-cell transfection is a powerful technique for delivering chemicals, drugs, or probes into arbitrary, specific single cells. This technique is especially important when the analysis of molecular function and cellular behavior in individual microscopic organisms such as protists requires the precise identification of the target cell, as fluorescence labeling of bulk populations makes tracking of individual motile protists virtually impossible. Herein, we have modified current single-cell electroporation techniques for delivering fluorescent markers into single Euglena gracilis, a motile photosynthetic microalga. Single-cell electroporation introduced molecules into individual living E. gracilis cells after a negative pressure was applied through a syringe connected to the micropipette to the target cell. The new method achieves high transfection efficiency and viability after electroporation. With the new technique, we successfully introduced a variety of molecules such as GFP, Alexa Fluor 488, and exciton-controlled hybridization-sensitive fluorescent oligonucleotide (ECHO) RNA probes into individual motile E. gracilis cells. We demonstrate imaging of endogenous mRNA in living E. gracilis without interfering with their physiological functions, such as swimming or division, over an extended period of time. Thus the modified single-cell electroporation technique is suitable for delivering versatile functional molecules into individual motile protists. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Fast and quantitative differentiation of single-base mismatched DNA by initial reaction rate of catalytic hairpin assembly.

    Science.gov (United States)

    Li, Chenxi; Li, Yixin; Xu, Xiao; Wang, Xinyi; Chen, Yang; Yang, Xiaoda; Liu, Feng; Li, Na

    2014-10-15

    The widely used catalytic hairpin assembly (CHA) amplification strategy generally needs several hours to accomplish one measurement based on the prevailingly used maximum intensity detection mode, making it less practical for assays where high throughput or speed is desired. To make the best use of the kinetic specificity of toehold domain for circuit reaction initiation, we developed a mathematical model and proposed an initial reaction rate detection mode to quantitatively differentiate the single-base mismatch. Using the kinetic mode, assay time can be reduced substantially to 10 min for one measurement with the comparable sensitivity and single-base mismatch differentiating ability as were obtained by the maximum intensity detection mode. This initial reaction rate based approach not only provided a fast and quantitative differentiation of single-base mismatch, but also helped in-depth understanding of the CHA system, which will be beneficial to the design of highly sensitive and specific toehold-mediated hybridization reactions. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Cumulative Success Rate of Short and Ultrashort Implants Supporting Single Crowns in the Posterior Maxilla: A 3-Year Retrospective Study.

    Science.gov (United States)

    Lombardo, Giorgio; Pighi, Jacopo; Marincola, Mauro; Corrocher, Giovanni; Simancas-Pallares, Miguel; Nocini, Pier Francesco

    2017-01-01

    To determine cumulative success rate (CSR) of short and ultrashort implants in the posterior maxilla restored with single crowns. We performed a retrospective study in 65 patients with 139 implants. 46 were ultrashort and 93 short. Implants were placed with a staged approach and restored with single crowns. Success rate, clinical and radiographic outcomes, and crown-to-implant ratio (CIR) were assessed after three years. Statistical analysis was performed by descriptive and inferential statistics. A log-binomial regression model where the main outcome was implant success was achieved. Coefficients and 95% confidence intervals were reported. Analyses were performed with Stata 13.2 for Windows. 61.54% of patients were female and mean overall age was 51.9 ± 11.08 years old. Overall CSR was 97.1% (95% CI: 92.4-98.9): 97.9 and 95.1% for short and ultrashort, respectively ( P value: 0.33). Four implants failed. Covariates were not associated with CSR ( P value > 0.05). Regression model showed coefficients correlated with implant success for ultrashort implants (0.87) and most of covariates but none were statistically significant ( P values > 0.05). Our results suggest that short and ultrashort implants may be successfully placed and restored with single crowns in the resorbed maxillary molar region.

  2. Hybrid coupled cluster methods: combining active space coupled cluster methods with coupled cluster singles, doubles, and perturbative triples.

    Science.gov (United States)

    Kou, Zhuangfei; Shen, Jun; Xu, Enhua; Li, Shuhua

    2012-05-21

    Based on the coupled-cluster singles, doubles, and a hybrid treatment of triples (CCSD(T)-h) method developed by us [J. Shen, E. Xu, Z. Kou, and S. Li, J. Chem. Phys. 132, 114115 (2010); and ibid. 133, 234106 (2010); and ibid. 134, 044134 (2011)], we developed and implemented a new hybrid coupled cluster (CC) method, named CCSD(T)q-h, by combining CC singles and doubles, and active triples and quadruples (CCSDtq) with CCSD(T) to deal with the electronic structures of molecules with significant multireference character. These two hybrid CC methods can be solved with non-canonical and canonical MOs. With canonical MOs, the CCSD(T)-like equations in these two methods can be solved directly without iteration so that the storage of all triple excitation amplitudes can be avoided. A practical procedure to divide canonical MOs into active and inactive subsets is proposed. Numerical calculations demonstrated that CCSD(T)-h with canonical MOs can well reproduce the corresponding results obtained with non-canonical MOs. For three atom exchange reactions, we found that CCSD(T)-h can offer a significant improvement over the popular CCSD(T) method in describing the reaction barriers. For the bond-breaking processes in F(2) and H(2)O, our calculations demonstrated that CCSD(T)q-h is a good approximation to CCSDTQ over the entire bond dissociation processes.

  3. Standard Test Method for Determining Thermal Neutron Reaction Rates and Thermal Neutron Fluence Rates by Radioactivation Techniques

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 The purpose of this test method is to define a general procedure for determining an unknown thermal-neutron fluence rate by neutron activation techniques. It is not practicable to describe completely a technique applicable to the large number of experimental situations that require the measurement of a thermal-neutron fluence rate. Therefore, this method is presented so that the user may adapt to his particular situation the fundamental procedures of the following techniques. 1.1.1 Radiometric counting technique using pure cobalt, pure gold, pure indium, cobalt-aluminum, alloy, gold-aluminum alloy, or indium-aluminum alloy. 1.1.2 Standard comparison technique using pure gold, or gold-aluminum alloy, and 1.1.3 Secondary standard comparison techniques using pure indium, indium-aluminum alloy, pure dysprosium, or dysprosium-aluminum alloy. 1.2 The techniques presented are limited to measurements at room temperatures. However, special problems when making thermal-neutron fluence rate measurements in high-...

  4. Single-center transfusion rate for 555 consecutive liver transplantations: impact of two eras.

    Science.gov (United States)

    Coêlho, G R; Feitosa Neto, B A; de G Teixeira, C C; Marinho, D S; Rangel, M L M; Garcia, J H P

    2013-11-01

    Orthotopic liver transplantation (OLT) is the treatment of choice for patients with acute or chronic end-stage liver disease, irresectable primary liver tumor, and metabolic disorders. Historically, OLT has been associated with considerable blood loss and the need for transfusions. However, over the years there has been reduction is need for blood products. The aim of this article was to compare two distinct eras for perioperative blood transfusion rate among patients undergoing OLT; Era I, 200 transplantations in 188 patients, and Era II, 355 transplantations in 339 patients. The donor mean age was 33.70 (Era I) versus 35.34 (Era II). Cause of death in both eras was traumatic brain injury followed by cerebral vascular accident. Organ recipient data showed a mean age of 48.87 (Era I) versus 46.49 (Era II). During Era I patients with Child B (56.8%) prevailed, followed by Child C (35.4%) and Child A (7.8%). In Era II also patients with Child B (53.1%) prevailed, followed by Child C (39.6%) and Child A (7.3%). The prevalence of hepatocellular carcinoma (HCC) during Era I was 9% (18) and in Era II 20% (71). The use of blood products in the perioperative period: was as follows packed red blood cells 1.76 (Era I) versus 0.57 (Era II) units; fresh frozen plasma 1.89 (Era I) versus 0.49 (Era II) units; platelets 2.16 (Era I) versus 0.28 (Era II) units; and cryoprecipitate 0.08 (Era I) versus 0.03 (Era II) units. OLT using the piggyback technique was performed with a transfusion rate below <30%, and it reduced blood loss and prevented severe hemodynamic instability. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Success rate of short dental implants supporting single crowns and fixed bridges.

    Science.gov (United States)

    Malmstrom, Hans; Gupta, Bhumija; Ghanem, Alexis; Cacciato, Rita; Ren, Yanfang; Romanos, Georgios E

    2016-09-01

    Bone grafts (sinus lift and/or ridge augmentation) may become an obstacle for some patients who desire implant treatment. The objective of this study was to evaluate the success of six- and eight-millimeters rough surface design short dental implants, for up to 2 years in function, when compared to conventional length (11 mm) implants. A total of 25.6-, 20.8- and 35.11-mm length implants were placed and restored in 30 subjects (11 males, 19 females) between the age of 22 and 80, following a standard protocol. Implant mobility, crestal bone loss as well as periodontal parameters were evaluated immediately after restoration placement, at 6, 12 and 24 months. There was one failure of one 6-mm implant during the healing phase and one restorative failure. The median crestal bone loss at 24 months was 0.45 mm for the 6-mm implants, 0.55 mm for the 8 mm implants and 0.65 mm for the 11-mm implants. The success rate for 6-mm implants was 97% and for 8-mm and 11-mm implants 100%. Based on this preliminary data, we conclude that rough surface design short dental implants (6 and 8 mm in length) have similar success rate when compared to 11-mm implants. Long-term data with larger number of implants and subjects are needed to confirm these results. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. A simple and rapid method for high-resolution visualization of single-ion tracks

    Directory of Open Access Journals (Sweden)

    Masaaki Omichi

    2014-11-01

    Full Text Available Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA-N, N’-methylene bisacrylamide (MBAAm blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  7. Single well surfactant test to evaluate surfactant floods using multi tracer method

    Science.gov (United States)

    Sheely, Clyde Q.

    1979-01-01

    Data useful for evaluating the effectiveness of or designing an enhanced recovery process said process involving mobilizing and moving hydrocarbons through a hydrocarbon bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well, comprising (a) determining hydrocarbon saturation in a volume in the formation near a well bore penetrating formation, (b) injecting sufficient mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore, and (c) determining the hydrocarbon saturation in a volume including at least a part of the volume of (b) by an improved single well surfactant method comprising injecting 2 or more slugs of water containing the primary tracer separated by water slugs containing no primary tracer. Alternatively, the plurality of ester tracers can be injected in a single slug said tracers penetrating varying distances into the formation wherein the esters have different partition coefficients and essentially equal reaction times. The single well tracer method employed is disclosed in U.S. Pat. No. 3,623,842. This method designated the single well surfactant test (SWST) is useful for evaluating the effect of surfactant floods, polymer floods, carbon dioxide floods, micellar floods, caustic floods and the like in subterranean formations in much less time and at much reduced cost compared to conventional multiwell pilot tests.

  8. The single-sink fixed-charge transportation problem: Applications and solution methods

    DEFF Research Database (Denmark)

    Goertz, Simon; Klose, Andreas

    2007-01-01

    The single-sink fixed-charge transportation problem (SSFCTP) consists in finding a minimum cost flow from a number of supplier nodes to a single demand node. Shipping costs comprise costs proportional to the amount shipped as well as a fixed-charge. Although the SSFCTP is an important special case...... of the well-known fixed-charge transportation problem, just a few methods for solving this problem have been proposed in the literature. After summarising some applications of this problem arising in manufacturing and transportation, we give an overview on approximation algorithms and worst-case results....... Finally, we briefly compare some exact solution algorithms for this problem....

  9. Method for single crystal growth of photovoltaic perovskite material and devices

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jinsong; Dong, Qingfeng

    2017-11-07

    Systems and methods for perovskite single crystal growth include using a low temperature solution process that employs a temperature gradient in a perovskite solution in a container, also including at least one small perovskite single crystal, and a substrate in the solution upon which substrate a perovskite crystal nucleates and grows, in part due to the temperature gradient in the solution and in part due to a temperature gradient in the substrate. For example, a top portion of the substrate external to the solution may be cooled.

  10. Error-free 5.1 Tbit/s data generation on a single-wavelength channel using a 1.28 Tbaud symbol rate

    DEFF Research Database (Denmark)

    Mulvad, Hans Christian Hansen; Galili, Michael; Oxenløwe, Leif Katsuo

    2009-01-01

    We demonstrate a record bit rate of 5.1 Tbit/s on a single wavelength using a 1.28 Tbaud OTDM symbol rate, DQPSK data-modulation, and polarisation-multiplexing. Error-free performance (BER......We demonstrate a record bit rate of 5.1 Tbit/s on a single wavelength using a 1.28 Tbaud OTDM symbol rate, DQPSK data-modulation, and polarisation-multiplexing. Error-free performance (BER...

  11. Multi-Level Wavelet Shannon Entropy-Based Method for Single-Sensor Fault Location

    Directory of Open Access Journals (Sweden)

    Qiaoning Yang

    2015-10-01

    Full Text Available In actual application, sensors are prone to failure because of harsh environments, battery drain, and sensor aging. Sensor fault location is an important step for follow-up sensor fault detection. In this paper, two new multi-level wavelet Shannon entropies (multi-level wavelet time Shannon entropy and multi-level wavelet time-energy Shannon entropy are defined. They take full advantage of sensor fault frequency distribution and energy distribution across multi-subband in wavelet domain. Based on the multi-level wavelet Shannon entropy, a method is proposed for single sensor fault location. The method firstly uses a criterion of maximum energy-to-Shannon entropy ratio to select the appropriate wavelet base for signal analysis. Then multi-level wavelet time Shannon entropy and multi-level wavelet time-energy Shannon entropy are used to locate the fault. The method is validated using practical chemical gas concentration data from a gas sensor array. Compared with wavelet time Shannon entropy and wavelet energy Shannon entropy, the experimental results demonstrate that the proposed method can achieve accurate location of a single sensor fault and has good anti-noise ability. The proposed method is feasible and effective for single-sensor fault location.

  12. The artificial compression method for computation of shocks and contact discontinuities. I - Single conservation laws

    Science.gov (United States)

    Harten, A.

    1977-01-01

    The paper discusses the use of the artificial compression method for the computation of discontinuous solutions of a single conservation law by finite difference methods. The single conservation law has either a shock or a contact discontinuity. Any monotone finite difference scheme applied to the original equation smears the discontinuity, while the same scheme applied to the equation modified by an artificial compression flux produces steady progressing profiles. If L is any finite difference scheme in conservation form and C is an artificial compressor, the split flux artificial compression method CL is a corrective scheme: L smears the discontinuity while propagating it; C compresses the smeared transition toward a sharp discontinuity. Numerical implementation of artificial compression is described.

  13. A method of dopant electron energy spectrum parameterization for calculation of single-electron nanodevices

    Science.gov (United States)

    Shorokhov, V. V.

    2017-05-01

    Solitary dopants in semiconductors and dielectrics that possess stable electron structures and interesting physical properties may be used as building blocks of quantum computers and sensor systems that operate based on new physical principles. This study proposes a phenomenological method of parameterization for a single-particle energy spectrum of dopant valence electrons in crystalline semiconductors and dielectrics that takes electron-electron interactions into account. It is proposed to take electron-electron interactions in the framework of the outer electron shell model into account. The proposed method is applied to construct the procedure for the determination of the effective dopant outer shell capacity and the method for calculation of the tunneling current in a single-electron device with one or several active dopants-charge centers.

  14. Analysis of a strain rate field in cold formed material using the visioplasticity method

    Directory of Open Access Journals (Sweden)

    L. Gusel

    2009-04-01

    Full Text Available In this paper the visioplasticity method is used to find the complete velocity and strain rate distributions from the experimental data, using the finite-difference method. The data about values of strain rates in plastic region of the material is very important for calculating stresses and the prediction of product quality. Specimens of copper alloy were extruded with different lubricants and different coefficients of friction and then the strain rate distributions were analysed and compared. Significant differences in velocity and strain rate distributions were obtained in some regions at the exit of the deformed zone.

  15. A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy

    Science.gov (United States)

    Chen, C-C; Lin, C-C; Chen, Y-J; Hong, S-W; Lu, T-W

    2013-01-01

    Objectives Accurate measurement of the three-dimensional (3D) motion of the mandible in vivo is essential for relevant clinical applications. Existing techniques are either of limited accuracy or require the use of transoral devices that interfere with jaw movements. This study aimed to develop further an existing method for measuring 3D, in vivo mandibular kinematics using single-plane fluoroscopy; to determine the accuracy of the method; and to demonstrate its clinical applicability via measurements on a healthy subject during opening/closing and chewing movements. Methods The proposed method was based on the registration of single-plane fluoroscopy images and 3D low-radiation cone beam CT data. It was validated using roentgen single-plane photogrammetric analysis at static positions and during opening/closing and chewing movements. Results The method was found to have measurement errors of 0.1 ± 0.9 mm for all translations and 0.2° ± 0.6° for all rotations in static conditions, and of 1.0 ± 1.4 mm for all translations and 0.2° ± 0.7° for all rotations in dynamic conditions. Conclusions The proposed method is considered an accurate method for quantifying the 3D mandibular motion in vivo. Without relying on transoral devices, the method has advantages over existing methods, especially in the assessment of patients with missing or unstable teeth, making it useful for the research and clinical assessment of the temporomandibular joint and chewing function. PMID:22842637

  16. Single-ended transition state finding with the growing string method.

    Science.gov (United States)

    Zimmerman, Paul M

    2015-04-05

    Reaction path finding and transition state (TS) searching are important tasks in computational chemistry. Methods that seek to optimize an evenly distributed set of structures to represent a chemical reaction path are known as double-ended string methods. Such methods can be highly reliable because the endpoints of the string are fixed, which effectively lowers the dimensionality of the reaction path search. String methods, however, require that the reactant and product structures are known beforehand, which limits their ability for systematic exploration of reactive steps. In this article, a single-ended growing string method (GSM) is introduced which allows for reaction path searches starting from a single structure. The method works by sequentially adding nodes along coordinates that drive bonds, angles, and/or torsions to a desired reactive outcome. After the string is grown and an approximate reaction path through the TS is found, string optimization commences and the exact TS is located along with the reaction path. Fast convergence of the string is achieved through use of internal coordinates and eigenvector optimization schemes combined with Hessian estimates. Comparison to the double-ended GSM shows that single-ended method can be even more computationally efficient than the already rapid double-ended method. Examples, including transition metal reactivity and a systematic, automated search for unknown reactivity, demonstrate the efficacy of the new method. This automated reaction search is able to find 165 reaction paths from 333 searches for the reaction of NH3 BH3 and (LiH)4 , all without guidance from user intuition. © 2015 Wiley Periodicals, Inc.

  17. 48 CFR 32.503-8 - Liquidation rates-ordinary method.

    Science.gov (United States)

    2010-10-01

    ... method. 32.503-8 Section 32.503-8 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... rates—ordinary method. The Government recoups progress payments through the deduction of liquidations... price of contract items delivered and accepted. The ordinary method is that the liquidation rate is the...

  18. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    Science.gov (United States)

    2001-10-25

    Penzel, Marburg University, through the Harvard-M.I.T. PhysioNet [6]. All of the eight-hour ECG recordings have been anno- tated for phases with sleep...AND METHODS 2.1 Material A data set of 70 ECGs with a recording duration between 401 and 578 min were used from the PhysioNet database [6] for the...X33 X34 X35 Table 1. Case classification A (gray) and C (white) with three variables From the PhysioNet Center this classification was evaluated as 28

  19. Selection of a method to rate the strength of scientific evidence for AORN recommendations.

    Science.gov (United States)

    Steelman, Victoria M; Pape, Theresa; King, Cecil A; Graling, Paula; Gaberson, Kathleen B

    2011-04-01

    The use of scientific evidence to support national recommendations about clinical decisions has become an expectation of multidisciplinary health care organizations. The objectives of this project were to identify the most applicable evidence-rating method for perioperative nursing practice, evaluate the reliability of this method for perioperative nursing recommendations, and identify barriers and facilitators to adoption of this method for AORN recommendations. A panel of perioperative nurse experts evaluated 46 evidence-rating systems for quality, quantity, and consistency. We rated the methods that fully covered all three domains on five aspects of applicability to perioperative nursing practice recommendations. The Oncology Nursing Society's method was rated highest for all five aspects of applicability, and interrater reliability of this method for perioperative recommendations was 100%. Potential barriers to implementation of the rating method include knowledge deficit, staff resources, resistance to change, and fear of showing that lower levels of evidence support some recommendations. Facilitators included education, resource allocation, and starting small. Barriers and facilitators will be considered by the implementation team that will develop a plan to achieve integration of evidence rating into AORN documents. The AORN Board of Directors approved adoption of this method in June 2010. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  20. Time-gated single-photon detection module with 110 ps transition time and up to 80 MHz repetition rate

    Energy Technology Data Exchange (ETDEWEB)

    Buttafava, Mauro, E-mail: mauro.buttafava@polimi.it; Boso, Gianluca; Ruggeri, Alessandro; Tosi, Alberto [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Dalla Mora, Alberto [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy)

    2014-08-15

    We present the design and characterization of a complete single-photon counting module capable of time-gating a silicon single-photon avalanche diode with ON and OFF transition times down to 110 ps, at repetition rates up to 80 MHz. Thanks to this sharp temporal filtering of incoming photons, it is possible to reject undesired strong light pulses preceding (or following) the signal of interest, allowing to increase the dynamic range of optical acquisitions up to 7 decades. A complete experimental characterization of the module highlights its very flat temporal response, with a time resolution of the order of 30 ps. The instrument is fully user-configurable via a PC interface and can be easily integrated in any optical setup, thanks to its small and compact form factor.

  1. A Novel MPPT Control Method of Thermoelectric Power Generation with Single Sensor

    Directory of Open Access Journals (Sweden)

    Tadashi Sakaguchi

    2013-04-01

    Full Text Available This paper proposes a novel Maximum Power Point Tracking (MPPT control method of thermoelectric power generation for the constant load. This paper reveals the characteristics and the internal resistance of thermoelectric power module (TM. Analyzing the thermoelectric power generation system with boost chopper by state space averaging method, the output voltage and current of TM are estimated by with only single current sensor. The proposed method can seek without calculating the output power of TM in this proposed method. The basic principle of the proposed MPPT control method is discussed, and then confirmed by digital computer simulation using PSIM. Simulation results demonstrate that the output voltage can track the maximum power point voltage by the proposed MPPT control method. The generated power of the TM is 0.36 W when the temperature difference is 35 °C. This is well accorded with the V-P characteristics.

  2. The method and equipment for the investigation of ions orienting transmission through thin single crystals

    CERN Document Server

    Soroka, V Y; Maznij, Y O

    2003-01-01

    A new approach is proposed to solve the task of angular distribution measurement of intensity strongly differentiated ions fluxes. Channeling effect makes this problem a regular feature of experimental study of ions orientating transmission through thin single crystals. The approach is based on the use of ions additional scattering by an amorphous (polycrystalline) target after passing through single crystal. The additional target manipulator is joined with the principal target chamber equipment with three-axis goniometer. The manipulator allows to move an additional target in the vicinity of the accelerator beam within the limits of +- 3 sup 0 in all directions and allows to measure the angular distribution of scattered ions with the accuracy of 1 min. The method and equipment were tested at the single ended electrostatic accelerator (EG-5) using a proton beam. At present the measurements have been resumed at the tandem accelerator (EG-10) of the Institute for Nuclear Research of the Academy of Sciences of U...

  3. Effects of withdrawal rate and starter block size on crystal orientation of a single crystal Ni-based superalloy

    Science.gov (United States)

    Rezaei, M.; Kermanpur, A.; Sadeghi, F.

    2018-03-01

    Fabrication of single crystal (SC) Ni-based gas turbine blades with a minimum crystal misorientation has always been a challenge in gas turbine industry, due to its significant influence on high temperature mechanical properties. This paper reports an experimental investigation and numerical simulation of the SC solidification process of a Ni-based superalloy to study effects of withdrawal rate and starter block size on crystal orientation. The results show that the crystal misorientation of the sample with 40 mm starter block height is decreased with increasing withdrawal rate up to about 9 mm/min, beyond which the amount of misorientation is increased. It was found that the withdrawal rate, height of the starter block and temperature gradient are completely inter-dependent and indeed achieving a SC specimen with a minimum misorientation needs careful optimization of these process parameters. The height of starter block was found to have higher impact on crystal orientation compared to the withdrawal rate. A suitable withdrawal rate regime along with a sufficient starter block height was proposed to produce SC parts with the lowest misorientation.

  4. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    Science.gov (United States)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  5. The Calculation Methods of the Specific Fuel Rate in Combined Heat and Electricity Production

    Directory of Open Access Journals (Sweden)

    I. A. Chuchueva

    2016-01-01

    Full Text Available The paper discusses a specific fuel rate in combined heat and electricity production using CHP technology. There are two objectives for calculation of specific fuel rate: a CHP technical efficiency estimate, b increasing CHP competitiveness at electricity and district heat markets. Currently, development of a number of thermo-dynamical methods of calculation solves the first problem while to solve the second one there is a number of developed economical methods of calculation. In Russia despite a decade of the wholesale electricity market progress the CHP market offers are still tightly connected with technical efficiency rate. To estimate the technical efficiency rate is widely used the least effective thermo-dynamical method – so called “physical” method”. The paper formulates a problem statement that is the specific fuel rate calculation and reviews the most widely applied methods. The review consists of two parts: in the first the Russian methods are discussed, and in the second one the methods widely used in the countries with highly developed electricity and district heat markets. A new thermo-dynamical method to calculate the specific fuel rate is introduced, which uses the linear characteristic curves of a steam turbine. The developed method allows us to take into consideration the energy inequality of the CHP products. Another advantages of this new method are calculation simplicity and small number of input data. To compare the effectiveness of different methods were introduced comparison rules and also calculations were performed. The comparison of thermo-dynamical methods shows that the most effective methods are an exergy method and also the method that takes into consideration the reduced generation of electricity (work method. Calculation complexity and large number of input data are main disadvantages of these methods. The comparison of economical methods shows that the most effective from stated point of view are a

  6. A comparative study of different methods for calculating electronic transition rates

    Science.gov (United States)

    Kananenka, Alexei A.; Sun, Xiang; Schubert, Alexander; Dunietz, Barry D.; Geva, Eitan

    2018-03-01

    We present a comprehensive comparison of the following mixed quantum-classical methods for calculating electronic transition rates: (1) nonequilibrium Fermi's golden rule, (2) mixed quantum-classical Liouville method, (3) mean-field (Ehrenfest) mixed quantum-classical method, and (4) fewest switches surface-hopping method (in diabatic and adiabatic representations). The comparison is performed on the Garg-Onuchic-Ambegaokar benchmark charge-transfer model, over a broad range of temperatures and electronic coupling strengths, with different nonequilibrium initial states, in the normal and inverted regimes. Under weak to moderate electronic coupling, the nonequilibrium Fermi's golden rule rates are found to be in good agreement with the rates obtained via the mixed quantum-classical Liouville method that coincides with the fully quantum-mechanically exact results for the model system under study. Our results suggest that the nonequilibrium Fermi's golden rule can serve as an inexpensive yet accurate alternative to Ehrenfest and the fewest switches surface-hopping methods.

  7. Evaluation of single and double centrifugation tube methods for concentrating equine platelets.

    Science.gov (United States)

    Argüelles, D; Carmona, J U; Pastor, J; Iborra, A; Viñals, L; Martínez, P; Bach, E; Prades, M

    2006-10-01

    The aim of this study was to evaluate single and double centrifugation tube methods for concentrating equine platelets. Whole blood samples were collected from clinically normal horses and processed by use of single and double centrifugation tube methods to obtain four platelet concentrates (PCs): PC-A, PC-B, PC-C, and PC-D, which were analyzed using a flow cytometry hematology system for hemogram and additional platelet parameters (mean platelet volume, platelet distribution width, mean platelet component concentration, mean platelet component distribution width). Concentrations of transforming growth factor beta 1 (TGF-beta(1)) were determined in all the samples. Platelet concentrations for PC-A, PC-B, PC-C, and PC-D were 45%, 44%, 71%, and 21% higher, respectively, compared to the same values for citrated whole blood samples. TGF-beta(1) concentrations for PC-A, PC-B, PC-C, and PC-D were 38%, 44%, 44%, and 37% higher, respectively, compared to citrated whole blood sample values. In conclusion, the single and double centrifugation tube methods are reliable methods for concentrating equine platelets and for obtaining potentially therapeutic TGF-beta(1) levels.

  8. A single-step method for rapid extraction of total lipids from green microalgae.

    Directory of Open Access Journals (Sweden)

    Martin Axelsson

    Full Text Available Microalgae produce a wide range of lipid compounds of potential commercial interest. Total lipid extraction performed by conventional extraction methods, relying on the chloroform-methanol solvent system are too laborious and time consuming for screening large numbers of samples. In this study, three previous extraction methods devised by Folch et al. (1957, Bligh and Dyer (1959 and Selstam and Öquist (1985 were compared and a faster single-step procedure was developed for extraction of total lipids from green microalgae. In the single-step procedure, 8 ml of a 2∶1 chloroform-methanol (v/v mixture was added to fresh or frozen microalgal paste or pulverized dry algal biomass contained in a glass centrifuge tube. The biomass was manually suspended by vigorously shaking the tube for a few seconds and 2 ml of a 0.73% NaCl water solution was added. Phase separation was facilitated by 2 min of centrifugation at 350 g and the lower phase was recovered for analysis. An uncharacterized microalgal polyculture and the green microalgae Scenedesmus dimorphus, Selenastrum minutum, and Chlorella protothecoides were subjected to the different extraction methods and various techniques of biomass homogenization. The less labour intensive single-step procedure presented here allowed simultaneous recovery of total lipid extracts from multiple samples of green microalgae with quantitative yields and fatty acid profiles comparable to those of the previous methods. While the single-step procedure is highly correlated in lipid extractability (r² = 0.985 to the previous method of Folch et al. (1957, it allowed at least five times higher sample throughput.

  9. The measurement of the fluence rate of accelerator fusion neutrons by using the associated particle method

    International Nuclear Information System (INIS)

    Wang Dalun; Li Yijun; Jiang Li

    1998-11-01

    The associated particle method is normally used to measure the fluence rate of accelerator fusion neutron. The principle, set-up and technical points are standardized. The measurement error is up to 1%∼1.5%

  10. Optimization of automation: III. Development of optimization method for determining automation rate in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Seung Min; Kim, Jong Hyun; Kim, Man Cheol; Seong, Poong Hyun

    2016-01-01

    Highlights: • We propose an appropriate automation rate that enables the best human performance. • We analyze the shortest working time considering Situation Awareness Recovery (SAR). • The optimized automation rate is estimated by integrating the automation and ostracism rate estimation methods. • The process to derive the optimized automation rate is demonstrated through case studies. - Abstract: Automation has been introduced in various industries, including the nuclear field, because it is commonly believed that automation promises greater efficiency, lower workloads, and fewer operator errors through reducing operator errors and enhancing operator and system performance. However, the excessive introduction of automation has deteriorated operator performance due to the side effects of automation, which are referred to as Out-of-the-Loop (OOTL), and this is critical issue that must be resolved. Thus, in order to determine the optimal level of automation introduction that assures the best human operator performance, a quantitative method of optimizing the automation is proposed in this paper. In order to propose the optimization method for determining appropriate automation levels that enable the best human performance, the automation rate and ostracism rate, which are estimation methods that quantitatively analyze the positive and negative effects of automation, respectively, are integrated. The integration was conducted in order to derive the shortest working time through considering the concept of situation awareness recovery (SAR), which states that the automation rate with the shortest working time assures the best human performance. The process to derive the optimized automation rate is demonstrated through an emergency operation scenario-based case study. In this case study, four types of procedures are assumed through redesigning the original emergency operating procedure according to the introduced automation and ostracism levels. Using the

  11. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  12. Polypeptide Translocation Through the Mitochondrial TOM Channel: Temperature-Dependent Rates at the Single-Molecule Level.

    Science.gov (United States)

    Mahendran, Kozhinjampara R; Lamichhane, Usha; Romero-Ruiz, Mercedes; Nussberger, Stephan; Winterhalter, Mathias

    2013-01-03

    The TOM protein complex facilitates the transfer of nearly all mitochondrial preproteins across outer mitochondrial membranes. Here we characterized the effect of temperature on facilitated translocation of a mitochondrial presequence peptide pF1β. Ion current fluctuations analysis through single TOM channels revealed thermodynamic and kinetic parameters of substrate binding and allowed determining the energy profile of peptide translocation. The activation energy for the on-rate and off-rate of the presequence peptide into the TOM complex was symmetric with respect to the electric field and estimated to be about 15 and 22 kT per peptide. These values are above that expected for free diffusion of ions in water (6 kT) and reflect the stronger interaction in the channel. Both values are in the range for typical enzyme kinetics and suggest one process without involving large conformational changes within the channel protein.

  13. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  14. Assessing Teachers' Judgements of Students' Academic Motivation and Emotions across Two Rating Methods

    Science.gov (United States)

    Zhu, Mingjing; Urhahne, Detlef

    2014-01-01

    The present study examines the accuracy of teachers' judgements about students' motivation and emotions in English learning with two different rating methods. A sample of 480 sixth-grade Chinese students reported their academic self-concept, learning effort, enjoyment, and test anxiety via a questionnaire and were rated on these dimensions by…

  15. METHODS OF CALCULATING DISCOUNT AND CAPITALIZATION RATES TO VALUATING REAL ESTATE IN ACCORDANCE WITH MARKETS CONDITIONS

    Directory of Open Access Journals (Sweden)

    L. Chubuk

    2013-09-01

    Full Text Available The existent methods of determination of the discount and capitalization rates for the valuation of the profitable real estate are analyzed from point of their prevalence, advantages and lacks of application. The alternative methods for setting the discount rates are selected (Galasyuk’s method. There are resulted recommendations in relation to approaching calculated size of the discount and capitalization rates to the real market information. In particular, expansion of the use of actually attained level of the expected return on the invested capital is offered. The actual values of capitalization rates on the office, commercial, ware-house real estate market in the capital of Ukraine are examined for period from 2008 to 2013, which evidence of considerable changeability of investment return indexes. There is confirmed the necessity of increasing the size of corrections in supply price to the level 18-20% for calculation of the capitalization rates after the method of market extraction. There is also propagates the account of additional market factors at the construction of recapitalization rates after the Invud’s method: annual growth (decline of leasing rates that are obtained from the profit real estate object; annual growth (decline of cost of the real property object; a percent of diminishing of cost of the real estate object in result of all kinds of depreciation (when residual value differ from a zero.

  16. A visualization method for probing grain boundaries of single layer graphene via molecular beam epitaxy

    Science.gov (United States)

    Zhan, Linjie; Wan, Wen; Zhu, Zhenwei; Zhao, Zhijuan; Zhang, Zhenhan; Shih, Tien-Mo; Cai, Weiwei

    2017-07-01

    Graphene, a member of layered two-dimensional (2D) materials, possesses high carrier mobility, mechanical flexibility, and optical transparency, as well as enjoying a wide range of promising applications in electronics. Adopting the chemical vaporization deposition method, the majority of investigators have ubiquitously grown single layer graphene (SLG), which inevitably involves polycrystalline properties. Here we demonstrate a simple method for the direct visualization of arbitrarily large-size SLG domains by synthesizing one-hundred-nm-scale MoS2 single crystals via a high-vacuum molecular beam epitaxy process. The present study based on epitaxial growth provides a guide for probing the grain boundaries of various 2D materials and implements higher potentials for the next-generation electronic devices.

  17. Method of preparing and applying single stranded DNA probes to double stranded target DNAs in situ

    Science.gov (United States)

    Gray, J.W.; Pinkel, D.

    1991-07-02

    A method is provided for producing single stranded non-self-complementary nucleic acid probes, and for treating target DNA for use therewith. The probe is constructed by treating DNA with a restriction enzyme and an exonuclease to form template/primers for a DNA polymerase. The digested strand is resynthesized in the presence of labeled nucleoside triphosphate precursor. Labeled single stranded fragments are separated from the resynthesized fragments to form the probe. Target DNA is treated with the same restriction enzyme used to construct the probe, and is treated with an exonuclease before application of the probe. The method significantly increases the efficiency and specificity of hybridization mixtures by increasing effective probe concentration by eliminating self-hybridization between both probe and target DNAs, and by reducing the amount of target DNA available for mismatched hybridizations. No Drawings

  18. Multicriteria decision-making method using the correlation coefficient under single-valued neutrosophic environment

    Science.gov (United States)

    Ye, Jun

    2013-05-01

    The paper presents the correlation and correlation coefficient of single-valued neutrosophic sets (SVNSs) based on the extension of the correlation of intuitionistic fuzzy sets and demonstrates that the cosine similarity measure is a special case of the correlation coefficient in SVNS. Then a decision-making method is proposed by the use of the weighted correlation coefficient or the weighted cosine similarity measure of SVNSs, in which the evaluation information for alternatives with respect to criteria is carried out by truth-membership degree, indeterminacy-membership degree, and falsity-membership degree under single-valued neutrosophic environment. We utilize the weighted correlation coefficient or the weighted cosine similarity measure between each alternative and the ideal alternative to rank the alternatives and to determine the best one(s). Finally, an illustrative example demonstrates the application of the proposed decision-making method.

  19. sup(99m)Tc-DTPA gamma-camera renography: Normal values and rapid determination of single-kidney glomerular filtration rate

    International Nuclear Information System (INIS)

    Rehling, M.; Moller, M.L.; Lund, J.O.; Trap-Jensen, J.; Jensen, K.B.; Thamdrup, B.

    1985-01-01

    A method for sup(99m)Tc-diethylenetriaminepentaacetate (DTPA) gamma-camera renography is presented. From each renogram an uptake index (UI) proportional to the single-kidney glomerular filtration rate (SKGFR) is defined. If the proportionality factor between UI and SKGFR is the same in all patients, UI can be used as an accurate measure of SKGFR. In order to test this, sup(99m)Tc-DTPA renography was performed in 101 patients with glomerular filtration rates (GFR) varying between 4 and 172 ml/min. The sum of the right- and left-kidney UIs correlated well with the total GFR calculated from the simultaneously measured plasma clearance of sup(99m)Tc-DTPA after a single injection. The correlation coefficient was 0.97. The method was tested in a prospective study of 57 patients. The total GFR estimated from the renograms was not significantly different from the GFR calculated from the plasma clearance of sup(99m)Tc-DTPA. The coefficient of variation -a combination of inaccuracy and imprecision in the estimates as well as in the reference values - was 11.8% at a GFR of 100 ml/min. It is concluded that, in adults, the SKGFR can be calculated as part of the clinical routine from sup(99m)Tc-DTPA gamma-camera renography without determining the injected dose or collecting urine or blood samples. Normal values for some parameters of the renogram obtained in 25 normal subjects are given. (orig.)

  20. New methods for estimating follow-up rates in cohort studies

    Directory of Open Access Journals (Sweden)

    Xiaonan Xue

    2017-12-01

    Full Text Available Abstract Background The follow-up rate, a standard index of the completeness of follow-up, is important for assessing the validity of a cohort study. A common method for estimating the follow-up rate, the “Percentage Method”, defined as the fraction of all enrollees who developed the event of interest or had complete follow-up, can severely underestimate the degree of follow-up. Alternatively, the median follow-up time does not indicate the completeness of follow-up, and the reverse Kaplan-Meier based method and Clark’s Completeness Index (CCI also have limitations. Methods We propose a new definition for the follow-up rate, the Person-Time Follow-up Rate (PTFR, which is the observed person-time divided by total person-time assuming no dropouts. The PTFR cannot be calculated directly since the event times for dropouts are not observed. Therefore, two estimation methods are proposed: a formal person-time method (FPT in which the expected total follow-up time is calculated using the event rate estimated from the observed data, and a simplified person-time method (SPT that avoids estimation of the event rate by assigning full follow-up time to all events. Simulations were conducted to measure the accuracy of each method, and each method was applied to a prostate cancer recurrence study dataset. Results Simulation results showed that the FPT has the highest accuracy overall. In most situations, the computationally simpler SPT and CCI methods are only slightly biased. When applied to a retrospective cohort study of cancer recurrence, the FPT, CCI and SPT showed substantially greater 5-year follow-up than the Percentage Method (92%, 92% and 93% vs 68%. Conclusions The Person-time methods correct a systematic error in the standard Percentage Method for calculating follow-up rates. The easy to use SPT and CCI methods can be used in tandem to obtain an accurate and tight interval for PTFR. However, the FPT is recommended when event rates and

  1. A Tractable Method for Describing Complex Couplings between Neurons and Population Rate.

    Science.gov (United States)

    Gardella, Christophe; Marre, Olivier; Mora, Thierry

    2016-01-01

    Neurons within a population are strongly correlated, but how to simply capture these correlations is still a matter of debate. Recent studies have shown that the activity of each cell is influenced by the population rate, defined as the summed activity of all neurons in the population. However, an explicit, tractable model for these interactions is still lacking. Here we build a probabilistic model of population activity that reproduces the firing rate of each cell, the distribution of the population rate, and the linear coupling between them. This model is tractable, meaning that its parameters can be learned in a few seconds on a standard computer even for large population recordings. We inferred our model for a population of 160 neurons in the salamander retina. In this population, single-cell firing rates depended in unexpected ways on the population rate. In particular, some cells had a preferred population rate at which they were most likely to fire. These complex dependencies could not be explained by a linear coupling between the cell and the population rate. We designed a more general, still tractable model that could fully account for these nonlinear dependencies. We thus provide a simple and computationally tractable way to learn models that reproduce the dependence of each neuron on the population rate.

  2. Growth of Ce-Doped LSO Single Crystals by Stockbarger-Bridgman Modified Crystallization Method

    International Nuclear Information System (INIS)

    Namtalishvili, M.; Sanadze, T.; Basharuli, N.; Magalashvili, P.; Mikaberidze, A.; Razmadze, Z.; Gabeskiria, M.

    2006-01-01

    The modified Stockbarger-Bridgman method was suggested for the growth of optically perfect LSO:Ce single crystals. Our investigations have shown that the most perfect crystals are grown by by the horizontally directed crystallization. In this case the elements of directional crystallyzation are combined with the zone melting. Crystallization is carried out in the conditions of sufficiently developed mirror of meltin. As a result in this case the chemical purity of grown crystals increases. (author)

  3. Real-time Continuous Assessment Method for Mental and Physiological Condition using Heart Rate Variability

    Science.gov (United States)

    Yoshida, Yutaka; Yokoyama, Kiyoko; Ishii, Naohiro

    It is necessary to monitor the daily health condition for preventing stress syndrome. In this study, it was proposed the method assessing the mental and physiological condition, such as the work stress or the relaxation, using heart rate variability at real time and continuously. The instantanuous heart rate (HR), and the ratio of the number of extreme points (NEP) and the number of heart beats were calculated for assessing mental and physiological condition. In this method, 20 beats heart rate were used to calculate these indexes. These were calculated in one beat interval. Three conditions, which are sitting rest, performing mental arithmetic and watching relaxation movie, were assessed using our proposed algorithm. The assessment accuracies were 71.9% and 55.8%, when performing mental arithmetic and watching relaxation movie respectively. In this method, the mental and physiological condition was assessed using only 20 regressive heart beats, so this method is considered as the real time assessment method.

  4. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  6. Paraquat prohibition and change in the suicide rate and methods in South Korea.

    Directory of Open Access Journals (Sweden)

    Woojae Myung

    Full Text Available The annual suicide rate in South Korea is the highest among the developed countries. Paraquat is a highly lethal herbicide, commonly used in South Korea as a means for suicide. We have studied the effect of the 2011 paraquat prohibition on the national suicide rate and method of suicide in South Korea. We obtained the monthly suicide rate from 2005 to 2013 in South Korea. In our analyses, we adjusted for the effects of celebrity suicides, and economic, meteorological, and seasonal factors on suicide rate. We employed change point analysis to determine the effect of paraquat prohibition on suicide rate over time, and the results were verified by structural change analysis, an alternative statistical method. After the paraquat prohibition period in South Korea, there was a significant reduction in the total suicide rate and suicide rate by poisoning with herbicides or fungicides in all age groups and in both genders. The estimated suicide rates during this period decreased by 10.0% and 46.1% for total suicides and suicides by poisoning of herbicides or fungicides, respectively. In addition, method substitution effect of paraquat prohibition was found in suicide by poisoning by carbon monoxide, which did not exceed the reduction in the suicide rate of poisoning with herbicides or fungicides. In South Korea, paraquat prohibition led to a lower rate of suicide by paraquat poisoning, as well as a reduction in the overall suicide rate. Paraquat prohibition should be considered as a national suicide prevention strategy in developing and developed countries alongside careful observation for method substitution effects.

  7. Paraquat prohibition and change in the suicide rate and methods in South Korea.

    Science.gov (United States)

    Myung, Woojae; Lee, Geung-Hee; Won, Hong-Hee; Fava, Maurizio; Mischoulon, David; Nyer, Maren; Kim, Doh Kwan; Heo, Jung-Yoon; Jeon, Hong Jin

    2015-01-01

    The annual suicide rate in South Korea is the highest among the developed countries. Paraquat is a highly lethal herbicide, commonly used in South Korea as a means for suicide. We have studied the effect of the 2011 paraquat prohibition on the national suicide rate and method of suicide in South Korea. We obtained the monthly suicide rate from 2005 to 2013 in South Korea. In our analyses, we adjusted for the effects of celebrity suicides, and economic, meteorological, and seasonal factors on suicide rate. We employed change point analysis to determine the effect of paraquat prohibition on suicide rate over time, and the results were verified by structural change analysis, an alternative statistical method. After the paraquat prohibition period in South Korea, there was a significant reduction in the total suicide rate and suicide rate by poisoning with herbicides or fungicides in all age groups and in both genders. The estimated suicide rates during this period decreased by 10.0% and 46.1% for total suicides and suicides by poisoning of herbicides or fungicides, respectively. In addition, method substitution effect of paraquat prohibition was found in suicide by poisoning by carbon monoxide, which did not exceed the reduction in the suicide rate of poisoning with herbicides or fungicides. In South Korea, paraquat prohibition led to a lower rate of suicide by paraquat poisoning, as well as a reduction in the overall suicide rate. Paraquat prohibition should be considered as a national suicide prevention strategy in developing and developed countries alongside careful observation for method substitution effects.

  8. Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential

    Science.gov (United States)

    Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.

  9. Pregnancy risk assessment monitoring system in Ireland: methods and response rates

    LENUS (Irish Health Repository)

    O’Keeffe, Linda M.

    2014-06-01

    To describe response rates and characteristics associated with response to the Pregnancy Risk Assessment Monitoring System study in Ireland (PRAMS Ireland). Using hospital discharge records of live births at a large, urban, obstetric hospital, a sampling frame of approximately 2,400 mother-infant pairs were used to alternately sample 1,200 women. Mothers’ information including name, address, parity, age and infant characteristics such as sex and gestational age at delivery were extracted from records. Modes of contact included an invitation letter with option to opt out of the study, three mail surveys, a reminder letter and text message reminder for remaining non-respondents. Sixty-one per cent of women responded to the PRAMS Ireland survey over a 133 day response period. Women aged <30, single women, multiparous women and women with a preterm delivery were less likely to respond. Women participating in PRAMS Ireland were similar to the national birth profile in 2011 which had a mean age of 32, were 40 % primiparous, 33 % single or never married and had a 28 % caesarean section rate. Survey and protocol changes are required to increase response rates above recommended Centers for Disease Control and Prevention (CDC) thresholds of 65 % within the recommended 90 day data collection cycle. Additional efforts such as stratification and over-sampling are required to increase representativeness among hard to reach groups such as younger, single and multiparous women before expanding the project to an ongoing, national surveillance system in Ireland.

  10. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    Energy Technology Data Exchange (ETDEWEB)

    Lunden, Melissa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heredia, Elizabeth [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Logue, Jennifer [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison between different gas sampling methods, and the effect of different ventilation conditions.

  11. Critical evaluation of the pulsed laser method for single event effects testing and fundamental studies

    International Nuclear Information System (INIS)

    Melinger, J.S.; Buchner, S.; McMorrow, D.; Stapor, W.J.; Weatherford, T.R.; Campbell, A.B.; Eisen, H.

    1994-01-01

    In this paper the authors present an evaluation of the pulsed laser as a technique for single events effects (SEE) testing. They explore in detail the important optical effects, such as laser beam propagation, surface reflection, and linear and nonlinear absorption, which determine the nature of laser-generated charge tracks in semiconductor materials. While there are differences in the structure of laser- and ion-generated charge tracks, they show that in many cases the pulsed laser remains an invaluable tool for SEE testing. Indeed, for several SEE applications, they show that the pulsed laser method represents a more practical approach than conventional accelerator-based methods

  12. Single tracking location methods suppress speckle noise in shear wave velocity estimation.

    Science.gov (United States)

    Elegbe, Etana C; McAleavey, Stephen A

    2013-04-01

    In ultrasound-based elastography methods, the estimation of shear wave velocity typically involves the tracking of speckle motion due to an applied force. The errors in the estimates of tissue displacement, and thus shear wave velocity, are generally attributed to electronic noise and decorrelation due to physical processes. We present our preliminary findings on another source of error, namely, speckle-induced bias in phase estimation. We find that methods that involve tracking in a single location, as opposed to multiple locations, are less sensitive to this source of error since the measurement is differential in nature and cancels out speckle-induced phase errors.

  13. The method of arbitrarily large moments to calculate single scale processes in quantum field theory

    Directory of Open Access Journals (Sweden)

    Johannes Blümlein

    2017-08-01

    Full Text Available We devise a new method to calculate a large number of Mellin moments of single scale quantities using the systems of differential and/or difference equations obtained by integration-by-parts identities between the corresponding Feynman integrals of loop corrections to physical quantities. These scalar quantities have a much simpler mathematical structure than the complete quantity. A sufficiently large set of moments may even allow the analytic reconstruction of the whole quantity considered, holding in case of first order factorizing systems. In any case, one may derive highly precise numerical representations in general using this method, which is otherwise completely analytic.

  14. The method of arbitrarily large moments to calculate single scale processes in quantum field theory

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Schneider, Carsten [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC)

    2017-01-15

    We device a new method to calculate a large number of Mellin moments of single scale quantities using the systems of differential and/or difference equations obtained by integration-by-parts identities between the corresponding Feynman integrals of loop corrections to physical quantities. These scalar quantities have a much simpler mathematical structure than the complete quantity. A sufficiently large set of moments may even allow the analytic reconstruction of the whole quantity considered, holding in case of first order factorizing systems. In any case, one may derive highly precise numerical representations in general using this method, which is otherwise completely analytic.

  15. The un-making of a method: From rating scales to the study of psychological processes

    DEFF Research Database (Denmark)

    Rosenbaum, Philip J.; Valsiner, Jaan

    2011-01-01

    Rating scales are standard instruments in psychology. They force the research participant to provide a numerical estimate of an assumed “degree” of some characteristic along a linear scale. We prove that such numerical estimates are artifacts based on unknown psychological processes that are used...... estimates by the rating task overlooks the qualitative (structural) relation between the implied opposites. We propose the reconstruction of the rating tasks into a method that accesses the process of meaning construction by the rater. When the rater faces a rating task, a field of meanings is constructed...

  16. [A new method of calibration and positioning in quantitative analysis of multicomponents by single marker].

    Science.gov (United States)

    He, Bing; Yang, Shi-Yan; Zhang, Yan

    2012-12-01

    This paper aims to establish a new method of calibration and positioning in quantitative analysis of multicomponents by single marker (QAMS), using Shuanghuanglian oral liquid as the research object. Establishing relative correction factors with reference chlorogenic acid to other 11 active components (neochlorogenic acid, cryptochlorogenic acid, cafferic acid, forsythoside A, scutellarin, isochlorogenic acid B, isochlorogenic acid A, isochlorogenic acid C, baicalin and phillyrin wogonoside) in Shuanghuanglian oral liquid by 3 correction methods (multipoint correction, slope correction and quantitative factor correction). At the same time chromatographic peak was positioned by linear regression method. Only one standard uas used to determine the content of 12 components in Shuanghuanglian oral liquid, in stead of needing too many reference substance in quality control. The results showed that within the linear ranges, no significant differences were found in the quantitative results of 12 active constituents in 3 batches of Shuanghuanglian oral liquid determined by 3 correction methods and external standard method (ESM) or standard curve method (SCM). And this method is simpler and quicker than literature methods. The results were accurate and reliable, and had good reproducibility. While the positioning chromatographic peaks by linear regression method was more accurate than relative retention time in literature. The slope and the quantitative factor correction controlling the quality of Chinese traditional medicine is feasible and accurate.

  17. Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Ye, Hong [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro A. [21st Century Oncology, Farmington Hills, Michigan (United States); Mitchell, Beth; Sebastian, Evelyn; Limbacher, Amy; Gustafson, Gary S. [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2017-01-01

    Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

  18. Direct Measurements of the Ozone Production Rate: Methods, Measurements, and Implications for Air Quality Monitoring

    Science.gov (United States)

    Brune, W. H.; Baier, B.; Miller, D. O.; Apel, E. C.; Wisthaler, A.; Fried, A.; Cantrell, C. A.; Blake, D. R.; Brown, S. S.; McDuffie, E. E.; Kaser, L.; Long, R.; Weinheimer, A. J.

    2017-12-01

    Ground level ozone pollution remains a health hazard in the United States despite dramatic reductions due to regulatory actions over the past three decades. The key to understanding the link between the ozone precursor gases, nitrogen oxides (NOx) and volatile organic compounds (VOCs), and ozone pollution is the ozone production rate. However, in air quality models, uncertainties in emissions and meteorology hide the true sensitivity of modeled ozone to the chemistry of the ozone production rate. A better way to understand the ozone production rate is to measure it directly. We devised a method for measuring the ozone production rate directly and have deployed it in a few field studies. In this presentation, we will discuss some fairly recent observations, the strengths and weaknesses of the current method, and a path toward routine monitoring of the ozone production rate.

  19. Method of Euthanasia Influences the Oocyte Fertilization Rate with Fresh Mouse Sperm

    Science.gov (United States)

    Hazzard, Karen C; Watkins-Chow, Dawn E; Garrett, Lisa J

    2014-01-01

    In vitro fertilization (IVF) is used to produce mouse embryos for a variety of reasons. We evaluated the effect of the method of euthanasia on the fertilization rate in 2 different IVF protocols. Oocytes collected from C57BL/6J female mice euthanized by CO2 inhalation or cervical dislocation were used in IVF with fresh sperm from either wild-type or genetically engineered C57BL/6J. Compared with CO2 inhalation, cervical dislocation improved the resulting rate of fertilization by 18% in an IVF method using Cook media and by 13% in an IVF method using methyl-B cyclodextrin and reduced glutathione. The lower fertilization rate due to euthanasia by CO2 inhalation was accompanied by changes in blood pH and body temperature despite efforts to minimize temperature drops. In our hands, euthanasia by cervical dislocation improved fertilization rates and consequently reduced the number of egg-donor mice required. PMID:25650969

  20. Series solution for continuous population models for single and interacting species by the homotopy analysis method

    Directory of Open Access Journals (Sweden)

    Magdy A. El-Tawil

    2012-07-01

    Full Text Available The homotopy analysis method (HAM is used to find approximate analytical solutions of continuous population models for single and interacting species. The homotopy analysis method contains the auxiliary parameter $hbar,$ which provides us with a simple way to adjust and control the convergence region of series solution. the solutions are compared with the numerical results obtained using NDSolve, an ordinary differential equation solver found in the Mathematica package and a good agreement is found. Also the solutions are compared with the available analytic results obtained by other methods and more accurate and convergent series solution found. The convergence region is also computed which shows the validity of the HAM solution. This method is reliable and manageable.

  1. The "curved lead pathway" method to enable a single lead to reach any two intracranial targets.

    Science.gov (United States)

    Ding, Chen-Yu; Yu, Liang-Hong; Lin, Yuan-Xiang; Chen, Fan; Lin, Zhang-Ya; Kang, De-Zhi

    2017-01-11

    Deep brain stimulation is an effective way to treat movement disorders, and a powerful research tool for exploring brain functions. This report proposes a "curved lead pathway" method for lead implantation, such that a single lead can reach in sequence to any two intracranial targets. A new type of stereotaxic system for implanting a curved lead to the brain of human/primates was designed, the auxiliary device needed for this method to be used in rat/mouse was fabricated and verified in rat, and the Excel algorithm used for automatically calculating the necessary parameters was implemented. This "curved lead pathway" method of lead implantation may complement the current method, make lead implantation for multiple targets more convenient, and expand the experimental techniques of brain function research.

  2. Influencing factors of Gate's method to measure of glomerular filtration rate

    International Nuclear Information System (INIS)

    Wu Ha; Shi Hongcheng

    2009-01-01

    Glomerular filtration rate (GFR) is an important criterion to estimate renal function. 99 Tc m - diethylenetrimainepentaacetic acid renal dynamic imaging is one of method to measure GFR that it have the characteristics of simple and accurate. But the Gate's method may be influenced by many factors such as dose of imaging agent, outlined of regions of interest, kidney depth, and so on. (authors)

  3. Contamination Rates of Three Urine-Sampling Methods to Assess Bacteriuria in Pregnant Women

    NARCIS (Netherlands)

    Schneeberger, Caroline; van den Heuvel, Edwin R.; Erwich, Jan Jaap H. M.; Stolk, Ronald P.; Visser, Caroline E.; Geerlings, Suzanne E.

    OBJECTIVE: To estimate and compare contamination rates of three different urine-sampling methods in pregnant women to assess bacteriuria. METHODS: In this cross-sectional study, 113 pregnant women collected three different midstream urine samples consecutively: morning (first void); midstream (void

  4. Variational finite element method to study the absorption rate of drug ...

    African Journals Online (AJOL)

    Methods: The finite element method has been used to obtain the solution of the mass diffusion equation with appropriate boundary conditions. The tissue absorption rate of drug has been taken as the decreasing function of drug concentration from the skin surface towards the target site. The concentration at nodal points ...

  5. Interlaboratory comparison of three methods for the determination of the radon exhalation rate of building materials

    NARCIS (Netherlands)

    de Jong, P; van Dijk, W.; de Vries, W; van der Graaf, ER; Roelofs, LMM

    In this study three methods for the determination of the radon (Rn-222) exhalation rate of building materials are compared. All three are so-called purge-and-trap methods in which the sample is enclosed in a container from which the exhaled radon is continuously purged by a constant flow of nitrogen

  6. Comparison of two methods of inquiry for torture with East African refugees: single query versus checklist.

    Science.gov (United States)

    Westermeyer, Joseph; Hollifield, Michael; Spring, Marline; Johnson, David; Jaranson, James

    2011-01-01

    First to compare two methods of inquiry regarding torture: i.e., the traditional means of inquiry versus a checklist of torture experiences previously identified for these African refugees. Second, we hoped to identify factors that might influence refugees to not report torture on a single query when checklist data indicated torture events had occurred or to report torture when checklist data indicated that torture had not occurred. Consisted of queries to 1,134 community-dwelling East African refugees (Somalia and Ethiopia) regarding the presence-versus-absence of torture in Africa (single query), a checklist of torture experiences in Africa that we had previously identified as occurring in these groups, demography, non-torture traumatic experiences in Africa, and current posttraumatic symptoms. Showed that 14% of the study participants reported a torture experience on a checklist, but not on a single query. Nine percent responded positively to the single query on torture, but then failed to check any torture experience. Those reporting trauma on an open-ended query, but not on a checklist, had been highly traumatized in other ways (warfare, civil chaos, robbery, assault, rape, trauma during flight out of the country). Those who reported torture on the checklist but not on the single query reported fewer instances of torture, suggesting that perhaps a "threshold" of torture experience influenced the single-query report. In addition, certain types of torture appeared more apt to be associated with a singlequery endorsement of torture. On regression analysis, a single-query self-report of torture was associated with traumatic experiences consistent with torture, older age, female gender, and nontorture trauma in Africa. Inconsistent reporting of torture occurred when two methods of inquiry (one openended and one a checklist) were employed in this sample. We believe that specific contexts of torture and non-torture trauma, together with individual demographic

  7. New Method Developed To Purify Single Wall Carbon Nanotubes for Aerospace Applications

    Science.gov (United States)

    Lebron, Marisabel; Meador, Michael A.

    2003-01-01

    Single wall carbon nanotubes have attracted considerable attention because of their remarkable mechanical properties and electrical and thermal conductivities. Use of these materials as primary or secondary reinforcements in polymers or ceramics could lead to new materials with significantly enhanced mechanical strength and electrical and thermal conductivity. Use of carbon-nanotube-reinforced materials in aerospace components will enable substantial reductions in component weight and improvements in durability and safety. Potential applications for single wall carbon nanotubes include lightweight components for vehicle structures and propulsion systems, fuel cell components (bipolar plates and electrodes) and battery electrodes, and ultra-lightweight materials for use in solar sails. A major barrier to the successful use of carbon nanotubes in these components is the need for methods to economically produce pure carbon nanotubes in large enough quantities to not only evaluate their suitability for certain applications but also produce actual components. Most carbon nanotube synthesis methods, including the HiPCO (high pressure carbon monoxide) method developed by Smalley and others, employ metal catalysts that remain trapped in the final product. These catalyst impurities can affect nanotube properties and accelerate their decomposition. The development of techniques to remove most, if not all, of these impurities is essential to their successful use in practical applications. A new method has been developed at the NASA Glenn Research Center to purify gram-scale quantities of single wall carbon nanotubes. This method, a modification of a gas phase purification technique previously reported by Smalley and others, uses a combination of high-temperature oxidations and repeated extractions with nitric and hydrochloric acid. This improved procedure significantly reduces the amount of impurities (catalyst and nonnanotube forms of carbon) within the nanotubes, increasing

  8. Implementation of Online Promethee Method for Poor Family Change Rate Calculation

    Science.gov (United States)

    Aji, Dhady Lukito; Suryono; Widodo, Catur Edi

    2018-02-01

    This research has been done online calculation of the rate of poor family change rate by using Preference Ranking Method of Organization Of Enrichment Evaluation (PROMETHEE) .This system is very useful to monitor poverty in a region as well as for administrative services related to poverty rate. The system consists of computer clients and servers connected via the internet network. Poor family residence data obtained from the government. In addition, survey data are inputted through the client computer in each administrative village and also 23 criteria of input in accordance with the established government. The PROMETHEE method is used to evaluate the value of poverty and its weight is used to determine poverty status. PROMETHEE output can also be used to rank the poverty of the registered population of the server based on the netflow value. The poverty rate is calculated based on the current poverty rate compared to the previous poverty rate. The rate results can be viewed online and real time on the server through numbers and graphs. From the test results can be seen that the system can classify poverty status, calculate the poverty rate change rate and can determine the value and poverty ranking of each population.

  9. Experimental Evaluation of a Method for Turbocharging Four-Stroke, Single Cylinder, Internal Combustion Engines

    Science.gov (United States)

    Buchman, Michael; Winter, Amos

    2015-11-01

    Turbocharging an engine increases specific power, improves fuel economy, reduces emissions, and lowers cost compared to a naturally aspirated engine of the same power output. These advantages make turbocharging commonplace for multi-cylinder engines. Single cylinder engineers are not commonly turbocharged due to the phase lag between the exhaust stroke, which powers the turbocharger, and the intake stroke, when air is pumped into the engine. Our proposed method of turbocharging single cylinder engines is to add an ``air capacitor'' to the intake manifold, an additional volume that acts as a buffer to store compressed air between the exhaust and intake strokes, and smooth out the pressure pulses from the turbocharger. This talk presents experimental results from a single cylinder, turbocharged diesel engine fit with various sized air capacitors. Power output from the engine was measured using a dynamometer made from a generator, with the electrical power dissipated with resistive heating elements. We found that intake air density increases with capacitor size as theoretically predicted, ranging from 40 to 60 percent depending on heat transfer. Our experiment was able to produce 29 percent more power compared to using natural aspiration. These results validated that an air capacitor and turbocharger may be a simple, cost effective means of increasing the power density of single cylinder engines.

  10. Comparing primary production methods to better constrain historical, current and future rates

    Science.gov (United States)

    Timmerman, A. H.; Hamme, R. C.

    2016-02-01

    Understanding current primary production and carbon export rates to the deep ocean will provide insight into possible climate change scenarios, because carbon export is an important mechanism sequestering carbon from the surface and may change in the future. By using multiple methods, production rates can be better constrained. Each method has its own advantages, disadvantages, and assumptions. By pairing methods, biases can be taken into account for data interpretation. For example, removing phytoplankton from the environment could change the light levels and temperature of the water. In addition, phytoplankton can be affected by the sides of the incubation container. By including in situ methods, bottle effects are removed and integration times are lengthened. In situ methods have their own set of disadvantages; uncertainty is introduced with the gas exchange rate and if surface water mixes with deeper water. However, comparing methods is complicated since each measures a different fraction of production (e.g net community, net primary, gross production). We present simultaneous in situ (O2/Ar, triple oxygen isotope), in vitro (13C, 15NO3, 15NH4, and 18O incubations) and satellite measurements of primary production from the subarctic northeast Pacific Ocean, Labrador Sea, Baffin Bay, and Canadian Arctic Archipelago. By comparing net community production (NCP; O2/Ar) to gross production (18O incubation or triple oxygen isotope), we estimate ecosystem efficiency. Some methods have multiple ways the rates could be calculated, but by comparing methods it could be possible to select the best options. Our goal is to identify conditions where the methods have consistent differences so measurements can be converted between methods and so ecosystem efficiency can be determined. By finding a way of converting to a more relevant export term (NCP), a wealth of 14C and 13C data exists that could be used to determine historic, current and future export rates.

  11. Household projections by the headship rates method: The case of Serbia

    Directory of Open Access Journals (Sweden)

    Vasić Petar

    2017-01-01

    Full Text Available The headship rates method (HRM of household projections based on the share of household heads in the total population of the same demographic characteristics (age, sex, nationality, marital status, etc. is the most commonly used method, especially by statistical institutes and planning institutions. The specific rates of household heads by age are calculated by dividing the number of household holders of a certain age with the total number of residents of the appropriate age. The future number of households is then simply projected on the basis of population projections by age and assumptions about the future changes of HR. The HRM is based on the projection of the future age structure of the population. In that sense, the choice of methods of population projection, as well as the method of projecting HR-s have determining impact on the outcome of household projections. Given the methodological inconsistency typical for official population projections in Serbia and significant differences in addressing uncertainty of the future population change between deterministic and probabilistic approach in making population projections, the decision to use a probabilistic projection of the population of Serbia as the basis for calculating the future number of house-holds and their structure according to the age of the household head proved to be a logical choice. However, as the basic aim of this article is to show the simple method of household projections, the above-mentioned stochastic projection is used in utterly deterministic manner. The median of the prediction interval of the population distributed across age is interpreted as the most probable future, or as a prognosis. The HR-s based on the age structure estimates and estimated number of households by age of the household head from Household budget survey (HBS are used for the purpose of HR projecting so that the number of observations would be large enough for calculating inclination parameters

  12. Determining Complex Structures using Docking Method with Single Particle Scattering Data

    Directory of Open Access Journals (Sweden)

    Haiguang Liu

    2017-04-01

    Full Text Available Protein complexes are critical for many molecular functions. Due to intrinsic flexibility and dynamics of complexes, their structures are more difficult to determine using conventional experimental methods, in contrast to individual subunits. One of the major challenges is the crystallization of protein complexes. Using X-ray free electron lasers (XFELs, it is possible to collect scattering signals from non-crystalline protein complexes, but data interpretation is more difficult because of unknown orientations. Here, we propose a hybrid approach to determine protein complex structures by combining XFEL single particle scattering data with computational docking methods. Using simulations data, we demonstrate that a small set of single particle scattering data collected at random orientations can be used to distinguish the native complex structure from the decoys generated using docking algorithms. The results also indicate that a small set of single particle scattering data is superior to spherically averaged intensity profile in distinguishing complex structures. Given the fact that XFEL experimental data are difficult to acquire and at low abundance, this hybrid approach should find wide applications in data interpretations.

  13. Determining Complex Structures using Docking Method with Single Particle Scattering Data.

    Science.gov (United States)

    Wang, Hongxiao; Liu, Haiguang

    2017-01-01

    Protein complexes are critical for many molecular functions. Due to intrinsic flexibility and dynamics of complexes, their structures are more difficult to determine using conventional experimental methods, in contrast to individual subunits. One of the major challenges is the crystallization of protein complexes. Using X-ray free electron lasers (XFELs), it is possible to collect scattering signals from non-crystalline protein complexes, but data interpretation is more difficult because of unknown orientations. Here, we propose a hybrid approach to determine protein complex structures by combining XFEL single particle scattering data with computational docking methods. Using simulations data, we demonstrate that a small set of single particle scattering data collected at random orientations can be used to distinguish the native complex structure from the decoys generated using docking algorithms. The results also indicate that a small set of single particle scattering data is superior to spherically averaged intensity profile in distinguishing complex structures. Given the fact that XFEL experimental data are difficult to acquire and at low abundance, this hybrid approach should find wide applications in data interpretations.

  14. Single Carrier Cyclic Prefix-Assisted CDMA System with Frequency Domain Equalization for High Data Rate Transmission

    Directory of Open Access Journals (Sweden)

    Madhukumar A. S.

    2004-01-01

    Full Text Available Multiple-access interference and interfinger interference limit the capacity of conventional single-carrier DS-CDMA systems. Even though multicarrier CDMA posses the advantages of conventional CDMA and OFDM, it suffers from two major implementation difficulties such as peak-to-average power ratio and high sensitivity to frequency offset and RF phase noise. A novel approach based on single-carrier cyclic prefix-assisted CDMA has been proposed to overcome the disadvantages of single-carrier CDMA and multicarrier modulation. The usefulness of the proposed approach for high-speed packet access with simplified channel estimation procedures are investigated in this paper. The paper also proposes a data-dependent pilot structure for the downlink transmission of the proposed system for enhancing pilot-assisted channel estimation in frequency domain. The performance of the proposed pilot structure is compared against the data-independent common pilot structure. The proposed system is extensively simulated for different channel parameters with different channel estimation and equalization methods and the results are compared against conventional multicarrier CDMA systems with identical system specifications.

  15. Single pulse two-photon fluorescence lifetime imaging (SP-FLIM) with MHz pixel rate and an all fiber based setup

    Science.gov (United States)

    Eibl, Matthias; Karpf, Sebastian; Hakert, Hubertus; Weng, Daniel; Pfeiffer, Tom; Kolb, Jan Philip; Huber, Robert

    2017-07-01

    Newly developed microscopy methods have the goal to give researches in bio-molecular science a better understanding of processes ongoing on a cellular level. Especially two-photon excited fluorescence (TPEF) microscopy is a readily applied and widespread modality. Compared to one photon fluorescence imaging, it is possible to image not only the surface but also deeper lying structures. Together with fluorescence lifetime imaging (FLIM), which provides information on the chemical composition of a specimen, deeper insights on a molecular level can be gained. However, the need for elaborate light sources for TPEF and speed limitations for FLIM hinder an even wider application. In this contribution, we present a way to overcome this limitations by combining a robust and inexpensive fiber laser for nonlinear excitation with a fast analog digitization method for rapid FLIM imaging. The applied sub nanosecond pulsed laser source is perfectly suited for fiber delivery as typically limiting non-linear effects like self-phase or cross-phase modulation (SPM, XPM) are negligible. Furthermore, compared to the typically applied femtosecond pulses, our longer pulses produce much more fluorescence photons per single shot. In this paper, we show that this higher number of fluorescence photons per pulse combined with a high analog bandwidth detection makes it possible to not only use a single pulse per pixel for TPEF imaging but also to resolve the exponential time decay for FLIM. To evaluate our system, we acquired FLIM images of a dye solution with single exponential behavior to assess the accuracy of our lifetime determination and also FLIM images of a plant stem at a pixel rate of 1 MHz to show the speed performance of our single pulse two-photon FLIM (SP-FLIM) system.

  16. Application of Statistical Methods of Rain Rate Estimation to Data From The TRMM Precipitation Radar

    Science.gov (United States)

    Meneghini, R.; Jones, J. A.; Iguchi, T.; Okamoto, K.; Liao, L.; Busalacchi, Antonio J. (Technical Monitor)

    2000-01-01

    The TRMM Precipitation Radar is well suited to statistical methods in that the measurements over any given region are sparsely sampled in time. Moreover, the instantaneous rain rate estimates are often of limited accuracy at high rain rates because of attenuation effects and at light rain rates because of receiver sensitivity. For the estimation of the time-averaged rain characteristics over an area both errors are relevant. By enlarging the space-time region over which the data are collected, the sampling error can be reduced. However. the bias and distortion of the estimated rain distribution generally will remain if estimates at the high and low rain rates are not corrected. In this paper we use the TRMM PR data to investigate the behavior of 2 statistical methods the purpose of which is to estimate the rain rate over large space-time domains. Examination of large-scale rain characteristics provides a useful starting point. The high correlation between the mean and standard deviation of rain rate implies that the conditional distribution of this quantity can be approximated by a one-parameter distribution. This property is used to explore the behavior of the area-time-integral (ATI) methods where fractional area above a threshold is related to the mean rain rate. In the usual application of the ATI method a correlation is established between these quantities. However, if a particular form of the rain rate distribution is assumed and if the ratio of the mean to standard deviation is known, then not only the mean but the full distribution can be extracted from a measurement of fractional area above a threshold. The second method is an extension of this idea where the distribution is estimated from data over a range of rain rates chosen in an intermediate range where the effects of attenuation and poor sensitivity can be neglected. The advantage of estimating the distribution itself rather than the mean value is that it yields the fraction of rain contributed by

  17. The Seepage Simulation of Single Hole and Composite Gas Drainage Based on LB Method

    Science.gov (United States)

    Chen, Yanhao; Zhong, Qiu; Gong, Zhenzhao

    2018-01-01

    Gas drainage is the most effective method to prevent and solve coal mine gas power disasters. It is very important to study the seepage flow law of gas in fissure coal gas. The LB method is a simplified computational model based on micro-scale, especially for the study of seepage problem. Based on fracture seepage mathematical model on the basis of single coal gas drainage, using the LB method during coal gas drainage of gas flow numerical simulation, this paper maps the single-hole drainage gas, symmetric slot and asymmetric slot, the different width of the slot combined drainage area gas flow under working condition of gas cloud of gas pressure, flow path diagram and flow velocity vector diagram, and analyses the influence on gas seepage field under various working conditions, and also discusses effective drainage method of the center hole slot on both sides, and preliminary exploration that is related to the combination of gas drainage has been carried on as well.

  18. Methods for the preparation of large quantities of complex single-stranded oligonucleotide libraries.

    Science.gov (United States)

    Murgha, Yusuf E; Rouillard, Jean-Marie; Gulari, Erdogan

    2014-01-01

    Custom-defined oligonucleotide collections have a broad range of applications in fields of synthetic biology, targeted sequencing, and cytogenetics. Also, they are used to encode information for technologies like RNA interference, protein engineering and DNA-encoded libraries. High-throughput parallel DNA synthesis technologies developed for the manufacture of DNA microarrays can produce libraries of large numbers of different oligonucleotides, but in very limited amounts. Here, we compare three approaches to prepare large quantities of single-stranded oligonucleotide libraries derived from microarray synthesized collections. The first approach, alkaline melting of double-stranded PCR amplified libraries with a biotinylated strand captured on streptavidin coated magnetic beads results in little or no non-biotinylated ssDNA. The second method wherein the phosphorylated strand of PCR amplified libraries is nucleolyticaly hydrolyzed is recommended when small amounts of libraries are needed. The third method combining in vitro transcription of PCR amplified libraries to reverse transcription of the RNA product into single-stranded cDNA is our recommended method to produce large amounts of oligonucleotide libraries. Finally, we propose a method to remove any primer binding sequences introduced during library amplification.

  19. Method for preparation and readout of polyatomic molecules in single quantum states

    Science.gov (United States)

    Patterson, David

    2018-03-01

    Polyatomic molecular ions contain many desirable attributes of a useful quantum system, including rich internal degrees of freedom and highly controllable coupling to the environment. To date, the vast majority of state-specific experimental work on molecular ions has concentrated on diatomic species. The ability to prepare and read out polyatomic molecules in single quantum states would enable diverse experimental avenues not available with diatomics, including new applications in precision measurement, sensitive chemical and chiral analysis at the single-molecule level, and precise studies of Hz-level molecular tunneling dynamics. While cooling the motional state of a polyatomic ion via sympathetic cooling with a laser-cooled atomic ion is straightforward, coupling this motional state to the internal state of the molecule has proven challenging. Here we propose a method for readout and projective measurement of the internal state of a trapped polyatomic ion. The method exploits the rich manifold of technically accessible rotational states in the molecule to realize robust state preparation and readout with far less stringent engineering than quantum logic methods recently demonstrated on diatomic molecules. The method can be applied to any reasonably small (≲10 atoms) polyatomic ion with an anisotropic polarizability.

  20. Charged-particle thermonuclear reaction rates: I. Monte Carlo method and statistical distributions

    International Nuclear Information System (INIS)

    Longland, R.; Iliadis, C.; Champagne, A.E.; Newton, J.R.; Ugalde, C.; Coc, A.; Fitzgerald, R.

    2010-01-01

    A method based on Monte Carlo techniques is presented for evaluating thermonuclear reaction rates. We begin by reviewing commonly applied procedures and point out that reaction rates that have been reported up to now in the literature have no rigorous statistical meaning. Subsequently, we associate each nuclear physics quantity entering in the calculation of reaction rates with a specific probability density function, including Gaussian, lognormal and chi-squared distributions. Based on these probability density functions the total reaction rate is randomly sampled many times until the required statistical precision is achieved. This procedure results in a median (Monte Carlo) rate which agrees under certain conditions with the commonly reported recommended 'classical' rate. In addition, we present at each temperature a low rate and a high rate, corresponding to the 0.16 and 0.84 quantiles of the cumulative reaction rate distribution. These quantities are in general different from the statistically meaningless 'minimum' (or 'lower limit') and 'maximum' (or 'upper limit') reaction rates which are commonly reported. Furthermore, we approximate the output reaction rate probability density function by a lognormal distribution and present, at each temperature, the lognormal parameters μ and σ. The values of these quantities will be crucial for future Monte Carlo nucleosynthesis studies. Our new reaction rates, appropriate for bare nuclei in the laboratory, are tabulated in the second paper of this issue (Paper II). The nuclear physics input used to derive our reaction rates is presented in the third paper of this issue (Paper III). In the fourth paper of this issue (Paper IV) we compare our new reaction rates to previous results.

  1. Survey Methods to Optimize Response Rate in the National Dental Practice-Based Research Network.

    Science.gov (United States)

    Funkhouser, Ellen; Vellala, Kavya; Baltuck, Camille; Cacciato, Rita; Durand, Emily; McEdward, Deborah; Sowell, Ellen; Theisen, Sarah E; Gilbert, Gregg H

    2017-09-01

    Surveys of health professionals typically have low response rates, and these rates have been decreasing in the recent years. We report on the methods used in a successful survey of dentist members of the National Dental Practice-Based Research Network. The objectives were to quantify the (1) increase in response rate associated with successive survey methods, (2) time to completion with each successive step, (3) contribution from the final method and personal contact, and (4) differences in response rate and mode of response by practice/practitioner characteristics. Dentist members of the network were mailed an invitation describing the study. Subsequently, up to six recruitment steps were followed: initial e-mail, two e-mail reminders at 2-week intervals, a third e-mail reminder with postal mailing a paper questionnaire, a second postal mailing of paper questionnaire, and staff follow-up. Of the 1,876 invited, 160 were deemed ineligible and 1,488 (87% of 1,716 eligible) completed the survey. Completion by step: initial e-mail, 35%; second e-mail, 15%; third e-mail, 7%; fourth e-mail/first paper, 11%; second paper, 15%; and staff follow-up, 16%. Overall, 76% completed the survey online and 24% on paper. Completion rates increased in absolute numbers and proportionally with later methods of recruitment. Participation rates varied little by practice/practitioner characteristics. Completion on paper was more likely by older dentists. Multiple methods of recruitment resulted in a high participation rate: Each step and method produced incremental increases with the final step producing the largest increase.

  2. DNA-electrophoresis of single cells - a method to screen for irradiated foodstuffs

    International Nuclear Information System (INIS)

    Leffke, A.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    Microelectrophoresis of single cells can be used to detect γ-irradiation over a wide dose range and for a variety of products. It is a simple and rapid test for DNA damages and can be used for screening. The method was tested on cell suspensions of bone marrow and muscle cells from frozen chicken legs, chicken heart, turkey liver, beef and pork irradiated with doses up to 3 kGy. Cell suspensions were prepared by incubation of tissues in EDTA-SDS-buffer at pH 8. Single cell electrophoresis was performed in 0.75% agarose gel. DNA was visualised by silver staining. In unirradiated samples no or only a small amount of DNA penetrated the cell membranes. Cells of irradiated samples appeared like a ''comet'' due to to migration of DNA-fragments out of cell. (orig.)

  3. SINGLE TREE DETECTION FROM AIRBORNE LASER SCANNING DATA USING A MARKED POINT PROCESS BASED METHOD

    Directory of Open Access Journals (Sweden)

    J. Zhang

    2013-05-01

    Full Text Available Tree detection and reconstruction is of great interest in large-scale city modelling. In this paper, we present a marked point process model to detect single trees from airborne laser scanning (ALS data. We consider single trees in ALS recovered canopy height model (CHM as a realization of point process of circles. Unlike traditional marked point process, we sample the model in a constraint configuration space by making use of image process techniques. A Gibbs energy is defined on the model, containing a data term which judge the fitness of the model with respect to the data, and prior term which incorporate the prior knowledge of object layouts. We search the optimal configuration through a steepest gradient descent algorithm. The presented hybrid framework was test on three forest plots and experiments show the effectiveness of the proposed method.

  4. Improved Design Methods for Robust Single- and Three-Phase ac-dc-ac Power Converters

    DEFF Research Database (Denmark)

    Qin, Zian

    After a century of fast developing, the society is facing energy issues again, e.g. the exhaustion of fossil fuel, emission caused air pollution, radiation leakage of nuclear generation, and so on. How to produce and use electricity in a more sustainable, efficient, and cost-effective way thus...... becomes a emerging challenge. Accordingly, installation of sustainable power generators like wind turbines and solar panels has experienced a large increase during the last decades. Meanwhile, power electronics converters, as interfaces in electrical system, are delivering approximately 80 % electricity......, the emerging challenges, and the structure of the thesis. The main content of the thesis starts with single-phase converters: Chapter 2 and Chapter 3 propose new modulation methods for single-phase B6 and H6 converters, respectively, in order to retain the same dc link voltage with two full-bridges connected...

  5. A method for determination of muscle fiber diameter using single fiber potential (SFP) analysis.

    Science.gov (United States)

    Zalewska, Ewa; Nandedkar, Sanjeev D; Hausmanowa-Petrusewicz, Irena

    2012-12-01

    We have used computer simulation to study the relationship between the muscle fiber diameter and parameters: peak-to-peak amplitude and duration of the negative peak of the muscle fiber action potential. We found that the negative peak duration is useful in the determination of fiber diameter via the diameter dependence of conduction velocity. We have shown a direct link between the underlying physiology and the measurements characterizing single fiber potential. Using data from simulations, a graphical tool and an analytical method to estimate the muscle fiber diameter from the recorded action potential has been developed. The ability to quantify the fiber diameter can add significantly to the single fiber electromyography examination. It may help study of muscle fiber diameter variability and thus compliment the muscle biopsy studies.

  6. A Bayes linear Bayes method for estimation of correlated event rates.

    Science.gov (United States)

    Quigley, John; Wilson, Kevin J; Walls, Lesley; Bedford, Tim

    2013-12-01

    Typically, full Bayesian estimation of correlated event rates can be computationally challenging since estimators are intractable. When estimation of event rates represents one activity within a larger modeling process, there is an incentive to develop more efficient inference than provided by a full Bayesian model. We develop a new subjective inference method for correlated event rates based on a Bayes linear Bayes model under the assumption that events are generated from a homogeneous Poisson process. To reduce the elicitation burden we introduce homogenization factors to the model and, as an alternative to a subjective prior, an empirical method using the method of moments is developed. Inference under the new method is compared against estimates obtained under a full Bayesian model, which takes a multivariate gamma prior, where the predictive and posterior distributions are derived in terms of well-known functions. The mathematical properties of both models are presented. A simulation study shows that the Bayes linear Bayes inference method and the full Bayesian model provide equally reliable estimates. An illustrative example, motivated by a problem of estimating correlated event rates across different users in a simple supply chain, shows how ignoring the correlation leads to biased estimation of event rates. © 2013 Society for Risk Analysis.

  7. Twinning processes in Cu-Al-Ni martensite single crystals investigated by neutron single crystal diffraction method

    Czech Academy of Sciences Publication Activity Database

    Molnar, P.; Šittner, P.; Novák, V.; Lukáš, Petr

    2008-01-01

    Roč. 481, Sp.Iss.SI (2008), s. 513-517 ISSN 0921-5093 R&D Projects: GA AV ČR IAA100480704 Institutional research plan: CEZ:AV0Z10480505 Keywords : Cu-Al-Ni * single crystals * neutron diffraction Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.806, year: 2008

  8. Single particle electron microscopy reconstruction of the exosome complex using the random conical tilt method.

    Science.gov (United States)

    Liu, Xueqi; Wang, Hong-Wei

    2011-03-28

    Single particle electron microscopy (EM) reconstruction has recently become a popular tool to get the three-dimensional (3D) structure of large macromolecular complexes. Compared to X-ray crystallography, it has some unique advantages. First, single particle EM reconstruction does not need to crystallize the protein sample, which is the bottleneck in X-ray crystallography, especially for large macromolecular complexes. Secondly, it does not need large amounts of protein samples. Compared with milligrams of proteins necessary for crystallization, single particle EM reconstruction only needs several micro-liters of protein solution at nano-molar concentrations, using the negative staining EM method. However, despite a few macromolecular assemblies with high symmetry, single particle EM is limited at relatively low resolution (lower than 1 nm resolution) for many specimens especially those without symmetry. This technique is also limited by the size of the molecules under study, i.e. 100 kDa for negatively stained specimens and 300 kDa for frozen-hydrated specimens in general. For a new sample of unknown structure, we generally use a heavy metal solution to embed the molecules by negative staining. The specimen is then examined in a transmission electron microscope to take two-dimensional (2D) micrographs of the molecules. Ideally, the protein molecules have a homogeneous 3D structure but exhibit different orientations in the micrographs. These micrographs are digitized and processed in computers as "single particles". Using two-dimensional alignment and classification techniques, homogenous molecules in the same views are clustered into classes. Their averages enhance the signal of the molecule's 2D shapes. After we assign the particles with the proper relative orientation (Euler angles), we will be able to reconstruct the 2D particle images into a 3D virtual volume. In single particle 3D reconstruction, an essential step is to correctly assign the proper orientation

  9. Combustion Model and Control Parameter Optimization Methods for Single Cylinder Diesel Engine

    Directory of Open Access Journals (Sweden)

    Bambang Wahono

    2014-01-01

    Full Text Available This research presents a method to construct a combustion model and a method to optimize some control parameters of diesel engine in order to develop a model-based control system. The construction purpose of the model is to appropriately manage some control parameters to obtain the values of fuel consumption and emission as the engine output objectives. Stepwise method considering multicollinearity was applied to construct combustion model with the polynomial model. Using the experimental data of a single cylinder diesel engine, the model of power, BSFC, NOx, and soot on multiple injection diesel engines was built. The proposed method succesfully developed the model that describes control parameters in relation to the engine outputs. Although many control devices can be mounted to diesel engine, optimization technique is required to utilize this method in finding optimal engine operating conditions efficiently beside the existing development of individual emission control methods. Particle swarm optimization (PSO was used to calculate control parameters to optimize fuel consumption and emission based on the model. The proposed method is able to calculate control parameters efficiently to optimize evaluation item based on the model. Finally, the model which added PSO then was compiled in a microcontroller.

  10. Comparing Single-Point and Multi-point Calibration Methods in Modulated DSC

    Energy Technology Data Exchange (ETDEWEB)

    Van Buskirk, Caleb Griffith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-14

    Heat capacity measurements for High Density Polyethylene (HDPE) and Ultra-high Molecular Weight Polyethylene (UHMWPE) were performed using Modulated Differential Scanning Calorimetry (mDSC) over a wide temperature range, -70 to 115 °C, with a TA Instruments Q2000 mDSC. The default calibration method for this instrument involves measuring the heat capacity of a sapphire standard at a single temperature near the middle of the temperature range of interest. However, this method often fails for temperature ranges that exceed a 50 °C interval, likely because of drift or non-linearity in the instrument's heat capacity readings over time or over the temperature range. Therefore, in this study a method was developed to calibrate the instrument using multiple temperatures and the same sapphire standard.

  11. Rapid synthesis of single-phase bismuth ferrite by microwave-assisted hydrothermal method

    International Nuclear Information System (INIS)

    Cao, Wenqian; Chen, Zhi; Gao, Tong; Zhou, Dantong; Leng, Xiaonan; Niu, Feng; Zhu, Yuxiang; Qin, Laishun; Wang, Jiangying; Huang, Yuexiang

    2016-01-01

    This paper describes on the fast synthesis of bismuth ferrite by the simple microwave-assisted hydrothermal method. The phase transformation and the preferred growth facets during the synthetic process have been investigated by X-ray diffraction. Bismuth ferrite can be quickly prepared by microwave hydrothermal method by simply controlling the reaction time, which is further confirmed by Fourier Transform infrared spectroscopy and magnetic measurement. - Graphical abstract: Single-phase BiFeO 3 could be realized at a shortest reaction time of 65 min. The reaction time has strong influences on the phase transformation and the preferred growth facets. - Highlights: • Rapid synthesis (65 min) of BiFeO 3 by microwave-assisted hydrothermal method. • Reaction time has influence on the purity and preferred growth facets. • FTIR and magnetic measurement further confirm the pure phase.

  12. Characterization of single-crystal sapphire substrates by X-ray methods and atomic force microscopy

    International Nuclear Information System (INIS)

    Prokhorov, I. A.; Zakharov, B. G.; Asadchikov, V. E.; Butashin, A. V.; Roshchin, B. S.; Tolstikhina, A. L.; Zanaveskin, M. L.; Grishchenko, Yu. V.; Muslimov, A. E.; Yakimchuk, I. V.; Volkov, Yu. O.; Kanevskii, V. M.; Tikhonov, E. O.

    2011-01-01

    The possibility of characterizing a number of practically important parameters of sapphire substrates by X-ray methods is substantiated. These parameters include wafer bending, traces of an incompletely removed damaged layer that formed as a result of mechanical treatment (scratches and marks), surface roughness, damaged layer thickness, and the specific features of the substrate real structure. The features of the real structure of single-crystal sapphire substrates were investigated by nondestructive methods of double-crystal X-ray diffraction and plane-wave X-ray topography. The surface relief of the substrates was investigated by atomic force microscopy and X-ray scattering. The use of supplementing analytical methods yields the most complete information about the structural inhomogeneities and state of crystal surface, which is extremely important for optimizing the technology of substrate preparation for epitaxy.

  13. Detection of Brucella melitensis and Brucella abortus strains using a single-stage PCR method

    Directory of Open Access Journals (Sweden)

    Alamian, S.

    2015-04-01

    Full Text Available Brucella melitensis and Brucella abortus are of the most important causes of brucellosis, an infectious disease which is transmitted either directly or indirectly including consuming unpasteurized dairy products. Both strains are considered endemic in Iran. Common diagnostic methods such as bacteriologic cultures are difficult and time consuming regarding the bacteria. The aim of this study was to suggest a single-stage PCR method using a pair of primers to detect both B. melitensis and B. abortus. The primers were named UF1 and UR1 and the results showed that the final size of PCR products were 84 bp and 99 bp for B. melitensis and B. abortus, respectively. Therefore the method could be useful for rapid detection of B. melitensis and B. abortus simultaneously.

  14. Comparison of Three Methods of Rating Nasolabial Appearance in Cleft Lip and Palate.

    Science.gov (United States)

    Fudalej, Sylwia A; Desmedt, Dries; Bronkhorst, Ewald; Fudalej, Piotr S

    2017-07-01

    To investigate which of three methods of rating nasolabial appearance-esthetic index, visual analogue scale (VAS), or numerical scale with reference photographs-is optimal. Experimental study. Radboud University Medical Centre, The Netherlands and University of Bern, Switzerland. Cropped photographs of 60 patients with complete unilateral cleft lip and palate (mean age = 10.8 years) were used for rating. A panel of eight raters rated four components of nasolabial morphology (nasal shape, nose deviation, vermillion border, and profile view) using three methods: 5-point esthetic index, 100 mm VAS, and 0 to 200 numerical scale with reference photographs (reference scores method). Method reliability was assessed by re-evaluation of 20 images after >1 month. Intraclass correlation coefficients were calculated to evaluate consistency of each method. Overall reference scores method always produced more reproducible results (i.e., higher ICCs) than did VAS or the esthetic index. However, statistically significant differences were found between reference scores and esthetic index in rating nasal shape, nose deviation, and vermillion border only (P scale. The esthetic index, based on a Likert-type scale, seems to produce the most variable results and, therefore, is not preferred.

  15. Research on criticality analysis method of CNC machine tools components under fault rate correlation

    Science.gov (United States)

    Gui-xiang, Shen; Xian-zhuo, Zhao; Zhang, Ying-zhi; Chen-yu, Han

    2018-02-01

    In order to determine the key components of CNC machine tools under fault rate correlation, a system component criticality analysis method is proposed. Based on the fault mechanism analysis, the component fault relation is determined, and the adjacency matrix is introduced to describe it. Then, the fault structure relation is hierarchical by using the interpretive structure model (ISM). Assuming that the impact of the fault obeys the Markov process, the fault association matrix is described and transformed, and the Pagerank algorithm is used to determine the relative influence values, combined component fault rate under time correlation can obtain comprehensive fault rate. Based on the fault mode frequency and fault influence, the criticality of the components under the fault rate correlation is determined, and the key components are determined to provide the correct basis for equationting the reliability assurance measures. Finally, taking machining centers as an example, the effectiveness of the method is verified.

  16. Thermal expansion and cooling rate dependence of transition temperature in ZrTiO4 single crystal

    International Nuclear Information System (INIS)

    Park, Y.

    1998-01-01

    Thermal expansion in ZrTiO 4 single crystal was investigated in the temperature range covering the normal, incommensurate, and commensurate phases. Remarkable change was found at the normal-incommensurate phase transition (T I ) in all thermal expansion coefficients a, b, and c. The spontaneous strains χ as and χ bs along the a and b axes show linear temperature dependence, while the spontaneous strain χ cs along the c axis shows a nonlinear temperature dependence. Small discontinuity along the c direction was observed at the incommensurate-commensurate transition temperature, T c = 845 C. dT I /dP and dT c /dP depend on the cooling rate

  17. Single daily dosing of antibiotics: importance of in vitro killing rate, serum half-life, and protein binding.

    Science.gov (United States)

    Potel, G; Chau, N P; Pangon, B; Fantin, B; Vallois, J M; Faurisson, F; Carbon, C

    1991-10-01

    The relative importance of pharmacokinetic and pharmacodynamic parameters for the feasibility of a single daily dose (SDD) of antibiotics remains to be established. Therefore, we studied the relationship between in vitro bacteriological parameters (MIC, MBC, and killing rate [KR], defined as the reduction in the inoculum within 3 h), pharmacokinetic parameters (t1/2 and protein binding [PB], and in vivo antibacterial effect of a single antibiotic dose in an experimental rabbit model of Escherichia coli endocarditis. Nine antibiotics were investigated: two aminoglycosides, two quinolones, and five beta-lactams. For each drug, the minimal effective dose (MED) (in milligrams per kilogram) was defined as the lowest dose able to achieve a significant difference (P less than 0.05) of CFU in the vegetations in comparison with controls 24 h after a single intravenous injection. Aminoglycosides and quinolones had the lowest MEDs, followed by beta-lactams. Univariate regression analysis showed that KR was the major determinant of MED. A stepwise regression analysis showed that t1/2 significantly improved the predictive value of KR, while PB, MIC, and MBC did not. The final equation was MED = 1,586-238 KR-297 t1/2 (r = 0.90, P = 0.01). We concluded that the pharmacodynamic parameters (especially the high KR) of aminoglycosides and quinolones explained their low MEDs and might allow SDD. In contrast, the low KR of beta-lactams emphasized the critical importance of a long t1/2, as for ceftriaxone, allowing the use of this beta-lactam alone in SDD.

  18. Direct immersion single drop micro-extraction method for multi-class pesticides analysis in mango using GC-MS.

    Science.gov (United States)

    Pano-Farias, Norma S; Ceballos-Magaña, Silvia G; Muñiz-Valencia, Roberto; Jurado, Jose M; Alcázar, Ángela; Aguayo-Villarreal, Ismael A

    2017-12-15

    Due the negative effects of pesticides on environment and human health, more efficient and environmentally friendly methods are needed. In this sense, a simple, fast, free from memory effects and economical direct-immersion single drop micro-extraction (SDME) method and GC-MS for multi-class pesticides determination in mango samples was developed. Sample pre-treatment using ultrasound-assisted solvent extraction and factors affecting the SDME procedure (extractant solvent, drop volume, stirring rate, ionic strength, time, pH and temperature) were optimized using factorial experimental design. This method presented high sensitive (LOD: 0.14-169.20μgkg -1 ), acceptable precision (RSD: 0.7-19.1%), satisfactory recovery (69-119%) and high enrichment factors (20-722). Several obtained LOQs are below the MRLs established by the European Commission; therefore, the method could be applied for pesticides determination in routing analysis and custom laboratories. Moreover, this method has shown to be suitable for determination of some of the studied pesticides in lime, melon, papaya, banana, tomato, and lettuce. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. A single-supply, high rate, small size and cheap electronic chain for 3He neutron counters

    International Nuclear Information System (INIS)

    Boffa, A.; Fazzi, A.; Pirovano, C.; Varoli, V.

    1996-01-01

    The paper describes a complete counting chain (charge preamplifier, shaping amplifier and threshold discriminator) devoted to 3 He neutron detectors. Since it is characterized by single supply operation, high counting rate, small size and low cost, it is well suited for high efficiency neutron well detectors where a large number (10 - 100) of counting tubes are used. Such detectors are commonly used for verification of Plutonium stocks. The preamplifier adopts an innovative circuit with the gate of the input JFET floating and a DC feedback loop that stabilizes the output voltage acting on the input cascode second transistor. Static and dynamic analysis, including the effects of the detector bias network, is reported. The shaping amplifier transfer function is a fifth order approximation of the gaussian response. All the complex pole pairs are realized with a single fourth order Voltage Controlled Voltage Source cell thus minimizing component count. Experimental signals and spectra, obtained with shaping time constants in the 1 μs - 100 ns range, are reported and discussed

  20. Efficiency of a single-rate and broad-based VAT system: the case of Bosnia and Herzegovina

    Directory of Open Access Journals (Sweden)

    Dinka Antić

    2014-09-01

    Full Text Available The aim of this paper is to analyze the performance and efficiency of the VAT system in B&H and explore the effects of internal and external factors influencing VAT collection. The VAT system in B&H is a consumption-type, single-rate and broad-based system. Ever since its implementation, VAT collection in B&H has been subject to strong oscillations, from an extremely high performance in the first two years after the introduction, to a sharp drop at the beginning of the crisis. After a temporary recovery, VAT collection declined in the last quarter of 2012 and has been negative ever since, although a weak recovery of the B&H economy was observed in 2013. The key hypothesis is that the high efficiency of the broadbased and single-rate structured VAT system may be neutralized by the country’s specific circumstances and VAT policy design. Applying a set of indicators for VAT efficiency analysis, developed by IMF, OECD and EU, we find a deterioration of the components of the policy gap caused by derogations of the VAT Law, and an increasing compliance gap, due to an increase of the VAT debt and tax evasion, in consequence of poor policy design in the field of excises. As a result of the influence of the country’s specific circumstances and its VAT policy design the identifiable current net losses on VAT in 2013 amount to 4% of net VAT collection or 0.4% of GDP. The analysis presented in the paper proves the main hypothesis that a VAT design, even when it is close to theoretically ideal concept, cannot on its own produce a high level of VAT efficiency and performance.

  1. Estimation of pea (Pisum sativum L.) microsatellite mutation rate based on pedigree and single-seed descent analyses.

    Science.gov (United States)

    Cieslarová, Jaroslava; Hanáček, Pavel; Fialová, Eva; Hýbl, Miroslav; Smýkal, Petr

    2011-11-01

    Microsatellites, or simple sequence repeats (SSRs) are widespread class of repetitive DNA sequences, used in population genetics, genetic diversity and mapping studies. In spite of the SSR utility, the genetic and evolutionary mechanisms are not fully understood. We have investigated three microsatellite loci with different position in the pea (Pisum sativum L.) genome, the A9 locus residing in LTR region of abundant retrotransposon, AD270 as intergenic and AF016458 located in 5'untranslated region of expressed gene. Comparative analysis of a 35 pair samples from seven pea varieties propagated by single-seed descent for ten generations, revealed single 4 bp mutation in 10th generation sample at AD270 locus corresponding to stepwise increase in one additional ATCT repeat unit. The estimated mutation rate was 4.76 × 10(-3) per locus per generation, with a 95% confidence interval of 1.2 × 10(-4) to 2.7 × 10(-2). The comparison of cv. Bohatýr accessions retrieved from different collections, showed intra-, inter-accession variation and differences in flanking and repeat sequences. Fragment size and sequence alternations were also found in long term in vitro organogenic culture, established at 1983, indicative of somatic mutation process. The evidence of homoplasy was detected across of unrelated pea genotypes, which adversaly affects the reliability of diversity estimates not only for diverse germplasm but also highly bred material. The findings of this study have important implications for Pisum phylogeny studies, variety identification and registration process in pea breeding where mutation rate influences the genetic diversity and the effective population size estimates.

  2. System and Method for Determining Rate of Rotation Using Brushless DC Motor

    Science.gov (United States)

    Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2000-01-01

    A system and method are provided for measuring rate of rotation. A brushless DC motor is rotated and produces a back electromagnetic force (emf) on each winding thereof. Each winding's back-emf is squared. The squared outputs associated with each winding are combined, with the square root being taken of such combination, to produce a DC output proportional only to the rate of rotation of the motor's shaft.

  3. Exposure rate by the spectrum dose index method using plastic scintillator detectors.

    Science.gov (United States)

    Proctor, Alan; Wellman, Jeffrey

    2012-04-01

    The spectrum dose index (SDI) method was tested for use with data from plastic scintillator detectors by irradiating a typical portal detector system using different gamma sources and natural background. Measurements were compared with exposure rates simultaneously measured using a calibrated pressurised ion chamber. It was found that a modified SDI algorithm could be used to calculate exposure rates for these detectors despite the lack of photopeaks in plastic scintillator spectra.

  4. The log mean heat transfer rate method of heat exchanger considering the influence of heat radiation

    International Nuclear Information System (INIS)

    Wong, K.-L.; Ke, M.-T.; Ku, S.-S.

    2009-01-01

    The log mean temperature difference (LMTD) method is conventionally used to calculate the total heat transfer rate of heat exchangers. Because the heat radiation equation contains the 4th order exponential of temperature which is very complicate in calculations, thus LMTD method neglects the influence of heat radiation. From the recent investigation of a circular duct in some practical situations, it is found that even in the situation of the temperature difference between outer duct surface and surrounding is low to 1 deg. C, the heat radiation effect can not be ignored in the situations of lower ambient convective heat coefficient and greater surface emissivities. In this investigation, the log mean heat transfer rate (LMHTR) method which considering the influence of heat radiation, is developed to calculate the total heat transfer rate of heat exchangers.

  5. Comparison of methods for estimating glomerular filtration rate in head and neck cancer patients treated with cisplatin

    DEFF Research Database (Denmark)

    Lindberg, Lotte; Brødbæk, Kasper; Hägerström, Erik G

    2017-01-01

    Cisplatin is a chemotherapeutic agent widely used in the treatment of various solid tumors. Cisplatin induces nephrotoxicity and may lead to long-term reduction of kidney function. Consequently, determination of glomerular filtration rate (GFR) is used to monitor potential kidney damage. This study...... aimed to compare two commonly used algorithms for estimating GFR (eGFR) from plasma creatinine (PCr) with 51Cr-EDTA clearance (CrCl) as a reference method. This was a retrospective single center study of 94 head and neck cancer patients treated with cisplatin. CrCl was performed once before, during......, and after treatment, and PCr was measured concurrently. eGFR was assessed from PCr applying the Cockcroft-Gault (CG) and the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equations. Agreement was assessed applying the statistical methods of Bland and Altman. A predefined limit of clinically...

  6. The BDS Triple Frequency Pseudo-range Correlated Stochastic Model of Single Station Modeling Method

    Directory of Open Access Journals (Sweden)

    HUANG Lingyong

    2017-05-01

    Full Text Available In order to provide a reliable pseudo-range stochastic model, a method is studied to estimate the BDS triple-frequency pseudo-range related stochastic model based on three BDS triple-frequency pseudo-range minus carrier (GIF combinations using the data of a single station. In this algorithm, the low order polynomial fitting method is used to fit the GIF combination in order to eliminate the error and other constants except non pseudo noise at first. And then, multiple linear regression analysis method is used to model the stochastic function of three linearly independent GIF combinations. Finally the related stochastic model of the original BDS triple-frequency pseudo-range observations is obtained by linear transformation. The BDS triple-frequency data verification results show that this algorithm can get a single station related stochastic model of BDS triple-frequency pseudo-range observation, and it is advantageous to provide accurate stochastic model for navigation and positioning and integrity monitoring.

  7. SWATH-ID: An instrument method which combines identification and quantification in a single analysis.

    Science.gov (United States)

    Kang, Yang; Burton, Lyle; Lau, Adam; Tate, Stephen

    2017-04-07

    Data-independent acquisition (DIA) approaches, such as SWATH ® -MS, are showing great potential to reliably quantify significant numbers of peptides and proteins in an unbiased manner. These developments have enhanced interest in developing a single DIA method which integrates qualitative and quantitative analysis, eliminating the need of a pre-built library of peptide spectra which are created through data-dependent acquisition (DDA) methods or from public repositories. Here we introduce a new DIA approach, referred to as "SWATH-ID", which was developed to allow peptide identification as well as quantitation. The SWATH-ID method is composed of small Q1 windows, achieving better selectivity and thus significantly improving high-confidence peptide extractions from data files. Furthermore, the SWATH-ID approach transmits precursor ions without fragmentation as well as their fragments within the same SWATH acquisition period. This provides a single scan which includes all precursor ions within the isolation window as well as a record of all of their fragment ions, substantially negating the need for a survey scan. In this way all precursors present in a small Q1 window are associated with their fragment ions, improving the identification specificity and providing a more comprehensive and in-depth view of protein and peptide species in complex samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Single determinant N-representability and the kernel energy method applied to water clusters.

    Science.gov (United States)

    Polkosnik, Walter; Massa, Lou

    2017-10-24

    The Kernel energy method (KEM) is a quantum chemical calculation method that has been shown to provide accurate energies for large molecules. KEM performs calculations on subsets of a molecule (called kernels) and so the computational difficulty of KEM calculations scales more softly than full molecule methods. Although KEM provides accurate energies those energies are not required to satisfy the variational theorem. In this article, KEM is extended to provide a full molecule single-determinant N-representable one-body density matrix. A kernel expansion for the one-body density matrix analogous to the kernel expansion for energy is defined. This matrix is converted to a normalized projector by an algorithm due to Clinton. The resulting single-determinant N-representable density matrix maps to a quantum mechanically valid wavefunction which satisfies the variational theorem. The process is demonstrated on clusters of three to twenty water molecules. The resulting energies are more accurate than the straightforward KEM energy results and all violations of the variational theorem are resolved. The N-representability studied in this article is applicable to the study of quantum crystallography. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. Radioeffects on the advanced breast cancer treated preoperatively by a single large dose irradiation method

    International Nuclear Information System (INIS)

    Mikuriya, Shuichi; Konoeda, Koichi; Mikami, Akihiko

    1981-01-01

    A single irradiation with a large electron dose was applied on 26 cases of advanced breast cancer in National Medical Center Hospital. Pertinent voltage from 6 to 20 MeV betatron electron was selected in accordance with tumor sizes. In eight patients, 30 Gy were given at once and other patients were irradiated with fractionated dose from 10 to 20 Gy, two or three times within 2 or 3 weeks (total 28 - 38 Gy). The radioresponse in primary and metastatic lesions was macroscopically, histopathologically and immunologically examined. Direct effects of preoperative irradiation of the primary lesions in 18 out of 24 cases (75%) were relatively remarkable by histopathological examinations. Remarkable cellular infiltrations into tumor nests of primary lesions were observed in 14 out of 24 cases (58%). Abscopal effects on metastatic lymph nodes were observed macroscopically in 7 of 20 cases (35%) and microscopic abscopal effects were seen in 10 of 20 cases (50%). In 6 cases among these ten cases macroscopic abscopal effects were associated with microscopic ones. In tests for cellular immunity, blastoid formation rates of lymphocytes induced by PHA in vitro, lymphocytes and absolute numbers of T-cells in peripheral blood slightly decreased after the irradiation. However, in four kinds of skin tests, enhancements of the response were confirmed. The crude survival rate for 3 years of Stage III cases revealed 83.3% and relative survival rate of these cases was 85.5%. A single large electron dose for the treatment of advanced breast cancer may inhibit the depression of immunoreaction in hosts. (J.P.N.)

  10. Survey of methods for the rating of psychiatric impairment in Australia.

    Science.gov (United States)

    Mendelson, George

    2004-05-01

    One of the enduring clinical issues in the assessment of plaintiffs in personal injury and workers' compensation claims, as well as applicants for social security and disablement benefits, is that of the evaluation of impairment and work incapacity. Many writers on this topic confuse the concepts of impairment and disability, and similar confusion is reflected in a number of the rating methods that purport to evaluate impairment but in reality assess disability. In Australia there are 20 distinct statutory schemes for workers' compensation, motor accident compensation, and social security and other benefits, which utilise a variety of methods for the rating of psychiatric impairment. Recent legislative changes designed to restrict access to personal injury compensation at common law, which in two Australian State jurisdictions require the use of impairment rating scales, also specify the rating methods to be used in the assessment of psychiatric impairment. This article discusses the concepts of impairment and disability as defined by the World Health Organisation, and reviews the various methods for the rating of psychiatric impairment that are specified by statute in the federal and State jurisdictions in Australia.

  11. Power quality improvement of single-phase photovoltaic systems through a robust synchronization method

    DEFF Research Database (Denmark)

    Hadjidemetriou, Lenos; Kyriakides, Elias; Yang, Yongheng

    2014-01-01

    An increasing amount of single-phase photovoltaic (PV) systems on the distribution network requires more advanced synchronization methods in order to meet the grid codes with respect to power quality and fault ride through capability. The response of the synchronization technique selected...... to the harmonic voltage distortion without affecting the dynamic response of the synchronization. Therefore, the accurate response of the proposed MHDC-PLL enhances the power quality of the PV inverter systems and additionally, the proper fault ride-through operation of PV systems can be enabled by the fast...

  12. Sources of variability for the single-comparator method in a heavy-water reactor

    International Nuclear Information System (INIS)

    Damsgaard, E.; Heydorn, K.

    1978-11-01

    The well thermalized flux in the heavy-water-moderated DR 3 reactor at Risoe prompted us to investigate to what extent a single comparator could be used for multi-element determination instead of multiple comparators. The reliability of the single-comparator method is limited by the thermal-to-epithermal ratio, and experiments were designed to determine the variations in this ratio throughout a reactor operating period (4 weeks including a shut-down period of 4-5 days). The bi-isotopic method using zirconium as monitor was chosen, because 94 Zr and 96 Zr exhibit a large difference in their Isub(o)/Σsub(th) values, and would permit determination of the flux ratio with a precision sufficient to determine variations. One of the irradiation facilities comprises a rotating magazine with 3 channels, each of which can hold five aluminium cans. In this rig, five cans, each holding a polyvial with 1 ml of aqueous zirconium solution were irradiated simultaneously in one channel. Irradiations were carried out in the first and the third week of 4 periods. In another facility consisting of a pneumatic tube system, two samples were simultaneously irradiated on top of each other in a polyethylene rabbit. Experiments were carried out once a week for 4 periods. All samples were counted on a Ge(Li)-detector for 95 Zr, 97 sup(m)Nb and 97 Nb. The thermal-to-epithermal flux ratio was calculated from the induced activity, the nuclear data for the two zirconium isotopes and the detector efficiency. By analysis of variance the total variation of the flux ratio was separated into a random variation between reactor periods, and systematic differences between the positions, as well as the weeks in the operating period. If the variations are in statistical control, the error resulting from use of the single-comparator method in multi-element determination can be estimated for any combination of irradiation position and day in the operating period. With the measure flux ratio variations in DR

  13. THE EFFECT OF EXCHANGE RATE ON THE CONSTRUCTION PROJECTS AND PROTECTION METHODS

    Directory of Open Access Journals (Sweden)

    Handan AKSUYEK,

    2017-02-01

    Full Text Available As with all sectors, recent extreme changes occurred in the exchange rates have substantially affected the construction operations. While the rise in foreign exchange rates leads to harmful effects in the negative direction at the operations having foreign exchange – based debt or it provides also advantageous effect in the positive direction at the construction companies having foreign exchange – indexed investments. In this context, this sudden change in foreign exchange rates which cannot be predicted beforehand and emerges as a result of speculative events. As with all operations carrying out foreign exchange – based tasks, these fluctuations in the foreign exchange rate head first among the factors which affect the achievement or failure of the cost or profit targets previously determined by the construction companies as well. Therefore, the companies whose costs and profits consist of different units of currency in their construction agreements should apply to the hedging methods in order to be protected against the exchange rate. As for the main tools of protection method are the derivative products such as forward, futures, swap and optional contracts. In this study, the effect of exchange rate fluctuations on the completion costs of construction projects is scrutinized. Moreover, the tools which may be employed by the construction companies in order to get rid of exchange rate which adversely influence the building companies in both directions have been comparatively evaluated.

  14. A Globally Convergent Matrix-Free Method for Constrained Equations and Its Linear Convergence Rate

    Directory of Open Access Journals (Sweden)

    Min Sun

    2014-01-01

    Full Text Available A matrix-free method for constrained equations is proposed, which is a combination of the well-known PRP (Polak-Ribière-Polyak conjugate gradient method and the famous hyperplane projection method. The new method is not only derivative-free, but also completely matrix-free, and consequently, it can be applied to solve large-scale constrained equations. We obtain global convergence of the new method without any differentiability requirement on the constrained equations. Compared with the existing gradient methods for solving such problem, the new method possesses linear convergence rate under standard conditions, and a relax factor γ is attached in the update step to accelerate convergence. Preliminary numerical results show that it is promising in practice.

  15. Method of measuring the mass flow rate of a substance entering a cocurrent fluid stream

    International Nuclear Information System (INIS)

    Cochran, H.D. Jr.

    1978-01-01

    An improved method of monitoring the mass flow rate of a substance entering a coherent fluid stream is described. The method very basically consists of heating equal sections of the fluid stream above and below the point of entry of the substance to be monitored, and measuring and comparing the resulting change in temperature of the sections. Advantage is taken of the difference in thermal characteristics of the fluid and the substance to be measured to correlate temperature differences in the sections above and below the substance feed point for providing an indication of the mass flow rate of the substance

  16. Growth of ZrSiO4 single crystal by flux method

    International Nuclear Information System (INIS)

    Ushio, Masumi; Nishitani, Yoshinari

    1982-01-01

    ZrSiO 4 single crystals were grown from the Na 2 O.3 V 2 O 5 fluxed melt at constant soaking temperatures of 900 0 C and 1000 0 C for periods up to 1710h, using the natural zircon seeds. Temperature difference between the seed and nutrient was 0.5 -- 5 0 C. A solubility curve of the natural zircon in Na 2 O.3 V 2 O 5 was determined. It was found that about 5.7g of the natural crystal dissolved in Na 2 O.3 V 2 O 5 in 48h at 1000 0 C and about 7.5g at 1200 0 C. .the maximum growth weight was about 0.35 2 g under conditions of the temperature difference of 2 0 C and the soaking for 1205h at 1000 0 C. The grown crystal was initially bounded with the c-, m-, p-, a-planes and very small planes consisting of the u- and x-, and finally bounded with the m- and p-planes. The observed linear growth rates of planes of ZrSiO 4 single crystals were in the following order:a(100) > c(001) > p(111) > m(110). The growth rates of a- and m-planes were about 5 -- 7 x 10 -4 mm/h and 0.9 -- 1.0 x 10 -4 mm/h, respectively. The growth hillocks of rounded triangular shape and elliptic shape extended to the direction of c-axis, were observed on the p- and m-planes, respectively. The observed step distence of the spiral and the step height were about 0.97 5 μm and 0.17 2 μm, respectively. The observed linear rate of advance of the step on the m-plane was about 0.4 0 -- 1.2 x 10 -8 cm/s. A linear growth rate of the m-plane was then calculated to be 0.2 5 -- 0.7 1 x 10 -4 mm/h by the BCF theory, which agreed in order of magnitude with the observes growth rate of the m-plabe. (author)

  17. Comparison of seven methods for producing Affymetrix expression scores based on False Discovery Rates in disease profiling data

    Directory of Open Access Journals (Sweden)

    Gruber Stephen B

    2005-02-01

    Full Text Available Abstract Background A critical step in processing oligonucleotide microarray data is combining the information in multiple probes to produce a single number that best captures the expression level of a RNA transcript. Several systematic studies comparing multiple methods for array processing have used tightly controlled calibration data sets as the basis for comparison. Here we compare performances for seven processing methods using two data sets originally collected for disease profiling studies. An emphasis is placed on understanding sensitivity for detecting differentially expressed genes in terms of two key statistical determinants: test statistic variability for non-differentially expressed genes, and test statistic size for truly differentially expressed genes. Results In the two data sets considered here, up to seven-fold variation across the processing methods was found in the number of genes detected at a given false discovery rate (FDR. The best performing methods called up to 90% of the same genes differentially expressed, had less variable test statistics under randomization, and had a greater number of large test statistics in the experimental data. Poor performance of one method was directly tied to a tendency to produce highly variable test statistic values under randomization. Based on an overall measure of performance, two of the seven methods (Dchip and a trimmed mean approach are superior in the two data sets considered here. Two other methods (MAS5 and GCRMA-EB are inferior, while results for the other three methods are mixed. Conclusions Choice of processing method has a major impact on differential expression analysis of microarray data. Previously reported performance analyses using tightly controlled calibration data sets are not highly consistent with results reported here using data from human tissue samples. Performance of array processing methods in disease profiling and other realistic biological studies should be

  18. The Relationship Between Method of Viewing Lectures, Course Ratings, and Course Timing

    Directory of Open Access Journals (Sweden)

    William B Burton

    2017-07-01

    Full Text Available Background: In recent years, medical schools have provided students access to video recordings of course lectures, but few studies have investigated the impact of this on ratings of courses and teachers. This study investigated whether the method of viewing lectures was related to student ratings of the course and its components and whether the method used changed over time. Methods: Preclinical medical students indicated whether ratings of course lectures were based primarily on lecture attendance, video capture, or both. Students were categorized into Lecture, Video, or Both groups based on their responses to this question. The data consisted of 7584 student evaluations collected over 2 years. Results: Students who attended live lectures rated the course and its components higher than students who only viewed the video or used both methods, although these differences were very small. Students increasingly watched lectures exclusively by video over time: in comparison with first-year students, second-year students were more likely to watch lectures exclusively by video; in comparison with students in the first half of the academic year, students in the second half of the academic year were more likely to watch lectures exclusively by video. Conclusions: With the increase in use of lecture video recordings across medical schools, attention must be paid to student attitudes regarding these methods.

  19. Effective information rates of single-carrier and multi-carrier modulation schemes for bandwidth constrained IM/DD systems

    KAUST Repository

    Mazahir, Sana

    2017-07-31

    Information-theoretic and signal processing aspects of some modulation schemes designed for intensity modulation/direct detection (IM/DD) optical wireless communication (OWC) systems are studied. Due to the constraints of IM/DD signals (non-negative real and baseband signals), the construction of these signals along with their time and frequency characteristics differ from their RF counterparts. This necessitates a careful study of such schemes under practical constraints. Three schemes are studied in this paper, namely, single carrier pulse amplitude modulation (SC-PAM), asymmetrically clipped optical OFDM (ACO-OFDM), and DC biased optical OFDM (DCO-OFDM). Our aim is to carry out a comparative study of these schemes in the presence of identical constraints on bandwidth and average optical power. The study reveals that the clipping operation required in ACO-OFDM significantly reduces its information rate, and as a result, it is outperformed by SC-PAM. Such a limitation does not apply to DCO-OFDM which has a higher information rate, even though part of the available optical power is expended in the non-information-bearing DC bias.

  20. Fabrication, characterization and electrochemical performance of single strand carbon fiber prepared by catalytic chemical vapor decomposition method

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Vrushali S. [Department of Chemistry, University of Pune, Ganeshkhind, Pune 411007, Maharashtra (India); Gokhale, Suresh P.; Patil, Kashinath R. [Physical and Material Chemistry Division, National Chemical Laboratory, Pune (India); Haram, Santosh K., E-mail: haram@chem.unipune.ernet.i [Department of Chemistry, University of Pune, Ganeshkhind, Pune 411007, Maharashtra (India)

    2010-02-15

    Preparation, fabrication and voltammetric characterizations of a single strand of carbon fiber (SSCF) electrode and their potential applications for biosensor are presented. SSCFs of diameter ca. 10 +- 2 mum and few millimeters in length are prepared by catalytic chemical vapor decomposition (CCVD) method. Voltammetry with potassium ferricyanide, alpha-methylferrocene methanol and hexaammineruthenium(III) chloride on SSCF electrode are used as bench marks to validate the electrode properties. Quasi-steady state voltammograms obtained were fitted into a cylindrical diffusion model. From which, the standard rate constant (k{sup 0}) and electron transfer coefficient (alpha) are obtained. The use of SSCF electrode is demonstrated for the voltammetric detection of the micromolar quantity of dopamine in the presence of large excess (ca. 200 times) of ascorbic acid, without any fouling of electrode surface. The kinetics of electron transfer are investigated.

  1. Fabrication, characterization and electrochemical performance of single strand carbon fiber prepared by catalytic chemical vapor decomposition method

    International Nuclear Information System (INIS)

    Joshi, Vrushali S.; Gokhale, Suresh P.; Patil, Kashinath R.; Haram, Santosh K.

    2010-01-01

    Preparation, fabrication and voltammetric characterizations of a single strand of carbon fiber (SSCF) electrode and their potential applications for biosensor are presented. SSCFs of diameter ca. 10 ± 2 μm and few millimeters in length are prepared by catalytic chemical vapor decomposition (CCVD) method. Voltammetry with potassium ferricyanide, α-methylferrocene methanol and hexaammineruthenium(III) chloride on SSCF electrode are used as bench marks to validate the electrode properties. Quasi-steady state voltammograms obtained were fitted into a cylindrical diffusion model. From which, the standard rate constant (k 0 ) and electron transfer coefficient (α) are obtained. The use of SSCF electrode is demonstrated for the voltammetric detection of the micromolar quantity of dopamine in the presence of large excess (ca. 200 times) of ascorbic acid, without any fouling of electrode surface. The kinetics of electron transfer are investigated.

  2. Estimation of turbulence dissipation rate by Large eddy PIV method in an agitated vessel

    Directory of Open Access Journals (Sweden)

    Kysela Bohuš

    2015-01-01

    Full Text Available The distribution of turbulent kinetic energy dissipation rate is important for design of mixing apparatuses in chemical industry. Generally used experimental methods of velocity measurements for measurement in complex geometries of an agitated vessel disallow measurement in resolution of small scales close to turbulence dissipation ones. Therefore, Particle image velocity (PIV measurement method improved by large eddy Ply approach was used. Large eddy PIV method is based on modeling of smallest eddies by a sub grid scale (SGS model. This method is similar to numerical calculations using Large Eddy Simulation (LES and the same SGS models are used. In this work the basic Smagorinsky model was employed and compared with power law approximation. Time resolved PIV data were processed by Large Eddy PIV approach and the obtained results of turbulent kinetic dissipation rate were compared in selected points for several operating conditions (impeller speed, operating liquid viscosity.

  3. Single-molecule techniques in biophysics: a review of the progress in methods and applications.

    Science.gov (United States)

    Miller, Helen; Zhou, Zhaokun; Shepherd, Jack; Wollman, Adam J M; Leake, Mark C

    2018-02-01

    Single-molecule biophysics has transformed our understanding of biology, but also of the physics of life. More exotic than simple soft matter, biomatter lives far from thermal equilibrium, covering multiple lengths from the nanoscale of single molecules to up to several orders of magnitude higher in cells, tissues and organisms. Biomolecules are often characterized by underlying instability: multiple metastable free energy states exist, separated by levels of just a few multiples of the thermal energy scale k B T, where k B is the Boltzmann constant and T absolute temperature, implying complex inter-conversion kinetics in the relatively hot, wet environment of active biological matter. A key benefit of single-molecule biophysics techniques is their ability to probe heterogeneity of free energy states across a molecular population, too challenging in general for conventional ensemble average approaches. Parallel developments in experimental and computational techniques have catalysed the birth of multiplexed, correlative techniques to tackle previously intractable biological questions. Experimentally, progress has been driven by improvements in sensitivity and speed of detectors, and the stability and efficiency of light sources, probes and microfluidics. We discuss the motivation and requirements for these recent experiments, including the underpinning mathematics. These methods are broadly divided into tools which detect molecules and those which manipulate them. For the former we discuss the progress of super-resolution microscopy, transformative for addressing many longstanding questions in the life sciences, and for the latter we include progress in 'force spectroscopy' techniques that mechanically perturb molecules. We also consider in silico progress of single-molecule computational physics, and how simulation and experimentation may be drawn together to give a more complete understanding. Increasingly, combinatorial techniques are now used, including

  4. Single-molecule techniques in biophysics: a review of the progress in methods and applications

    Science.gov (United States)

    Miller, Helen; Zhou, Zhaokun; Shepherd, Jack; Wollman, Adam J. M.; Leake, Mark C.

    2018-02-01

    Single-molecule biophysics has transformed our understanding of biology, but also of the physics of life. More exotic than simple soft matter, biomatter lives far from thermal equilibrium, covering multiple lengths from the nanoscale of single molecules to up to several orders of magnitude higher in cells, tissues and organisms. Biomolecules are often characterized by underlying instability: multiple metastable free energy states exist, separated by levels of just a few multiples of the thermal energy scale k B T, where k B is the Boltzmann constant and T absolute temperature, implying complex inter-conversion kinetics in the relatively hot, wet environment of active biological matter. A key benefit of single-molecule biophysics techniques is their ability to probe heterogeneity of free energy states across a molecular population, too challenging in general for conventional ensemble average approaches. Parallel developments in experimental and computational techniques have catalysed the birth of multiplexed, correlative techniques to tackle previously intractable biological questions. Experimentally, progress has been driven by improvements in sensitivity and speed of detectors, and the stability and efficiency of light sources, probes and microfluidics. We discuss the motivation and requirements for these recent experiments, including the underpinning mathematics. These methods are broadly divided into tools which detect molecules and those which manipulate them. For the former we discuss the progress of super-resolution microscopy, transformative for addressing many longstanding questions in the life sciences, and for the latter we include progress in ‘force spectroscopy’ techniques that mechanically perturb molecules. We also consider in silico progress of single-molecule computational physics, and how simulation and experimentation may be drawn together to give a more complete understanding. Increasingly, combinatorial techniques are now used, including

  5. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  6. Time-trends in method-specific suicide rates compared with the availability of specific compounds

    DEFF Research Database (Denmark)

    Nordentoft, Merete; Qin, Ping; Helweg-Larsen, Karin

    2006-01-01

    Restriction of means for suicide is an important part of suicide preventive strategies in different countries. All suicides in Denmark between 1970 and 2000 were examined with regard to method used for suicide. Overall suicide mortality and method-specific suicide mortality was compared...... in the number of suicides by self-poisoning with these compounds. Restricted access occurred concomittantly with a 55% decrease in suicide rate....

  7. Single image super-resolution via an iterative reproducing kernel Hilbert space method.

    Science.gov (United States)

    Deng, Liang-Jian; Guo, Weihong; Huang, Ting-Zhu

    2016-11-01

    Image super-resolution, a process to enhance image resolution, has important applications in satellite imaging, high definition television, medical imaging, etc. Many existing approaches use multiple low-resolution images to recover one high-resolution image. In this paper, we present an iterative scheme to solve single image super-resolution problems. It recovers a high quality high-resolution image from solely one low-resolution image without using a training data set. We solve the problem from image intensity function estimation perspective and assume the image contains smooth and edge components. We model the smooth components of an image using a thin-plate reproducing kernel Hilbert space (RKHS) and the edges using approximated Heaviside functions. The proposed method is applied to image patches, aiming to reduce computation and storage. Visual and quantitative comparisons with some competitive approaches show the effectiveness of the proposed method.

  8. Influence of modulation method on using LC-traps with single-phase voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Min, Huang; Bai, Haofeng

    2015-01-01

    The switching-frequency LC-trap filter has recently been employed with high-order passive filters for Voltage Source Inverters (VSIs). This paper investigates the influence of modulation method on using the LC-traps with single-phase VSIs. Two-level (bipolar) and three-level (unipolar) modulations...... that include phase distortion and alternative phase opposition distortion methods are analyzed. Harmonic filtering performances of four LC-trap-based filters with different locations of LC-traps are compared. It is shown that the use of parallel-LC-traps in series with filter inductors, either grid...... or converter side, has a worse harmonic filtering performance than using series-LC-trap in the shunt branch. Simulations and experimental results are presented for verifications....

  9. Capillary Electrophoresis Single-Strand Conformational Polymorphisms as a Method to Differentiate Algal Species

    Directory of Open Access Journals (Sweden)

    Alice Jernigan

    2015-01-01

    Full Text Available Capillary electrophoresis single-strand conformational polymorphism (CE-SSCP was explored as a fast and inexpensive method to differentiate both prokaryotic (blue-green and eukaryotic (green and brown algae. A selection of two blue-green algae (Nostoc muscorum and Anabaena inaequalis, five green algae (Chlorella vulgaris, Oedogonium foveolatum, Mougeotia sp., Scenedesmus quadricauda, and Ulothrix fimbriata, and one brown algae (Ectocarpus sp. were examined and CE-SSCP electropherogram “fingerprints” were compared to each other for two variable regions of either the 16S or 18S rDNA gene. The electropherogram patterns were remarkably stable and consistent for each particular species. The patterns were unique to each species, although some common features were observed between the different types of algae. CE-SSCP could be a useful method for monitoring changes in an algae species over time as potential shifts in species occurred.

  10. Estimation of 131J-Jodohippurateclearance by a simplified method using a single plasma sample

    International Nuclear Information System (INIS)

    Botsch, H.; Golde, G.; Kampf, D.

    1980-01-01

    Theoretical volumes calculated from the reciprocal of the plasma concentration of 131 J-Jodohippurate were compared in 95 patients with clearance values calculated by the 2-compartment-method and in 18 patients with conventional PAH-clearance. For estimating Hippurate-clearance from a single blood sampling the most favorable time is 45 min. after injection (r = 0.96; clearance 400/ml/min.: r = 0.98). Clearance values may be derived from the formula: C = 0.4 + 7.26 V - 0.021 x V 2 (V = injected activity/activity per l plasma taken 45 min. after injection). The simplicity, precision and reproducibility of the above mentioned clearance-method is emphasized. (orig.) [de

  11. Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J.A.M. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)], E-mail: a.miranda@portugalmail.pt; Sarmento, S. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Alves, P.; Torres, M.C. [Departamento de Fisica da Universidade do Porto, Rua do Campo Alegre 687, 4169-007 Porto (Portugal); Bastos, A.L. [Servico de Medicina Nuclear, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Ponte, F. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2008-01-15

    A new method for measuring simultaneously both the extrinsic sensitivity and spatial resolution of a gamma-camera in a single planar acquisition was implemented. A dual-purpose phantom (SR phantom; sensitivity/resolution) was developed, tested and the results compared with other conventional methods used for separate determination of these two important image quality parameters. The SR phantom yielded reproducible and accurate results, allowing an immediate visual inspection of the spatial resolution as well as the quantitative determination of the contrast for six different spatial frequencies. It also proved to be useful in the estimation of the modulation transfer function (MTF) of the image formation collimator/detector system at six different frequencies and can be used to estimate the spatial resolution as function of the direction relative to the digital matrix of the detector.

  12. Single Temperature Sensor Superheat Control Using a Novel Maximum Slope-seeking Method

    DEFF Research Database (Denmark)

    Vinther, Kasper; Rasmussen, Henrik; Izadi-Zamanabadi, Roozbeh

    2013-01-01

    Superheating of refrigerant in the evaporator is an important aspect of safe operation of refrigeration systems. The level of superheat is typically controlled by adjusting the flow of refrigerant using an electronic expansion valve, where the superheat is calculated using measurements from...... a pressure and a temperature sensor. In this paper we show, through extensive testing, that the superheat or filling of the evaporator can actually be controlled using only a single temperature sensor. This can either reduce commissioning costs by lowering the necessary amount of sensors or add fault...... tolerance in existing systems if a sensor fails (e.g. pressure sensor). The solution is based on a novel maximum slope-seeking control method, where a perturbation signal is added to the valve opening degree, which gives additional information about the system for control purposes. Furthermore, the method...

  13. Multiconfiguration self-consistent field method based on superposition of singly excited configurations

    International Nuclear Information System (INIS)

    Malykhanov, Yu.B.; Bochkova, R.V.

    1986-01-01

    The LCAO approximation has been used in deriving the equations in the multiconfiguration self-consistent field method, in which the function is taken as the superposition of the ground configuration and a singly excited singlet one (the MCSCF CI method). In the energy functional, one can vary not only the configurational factors and the molecular orbitals (LCAO coefficients) but also parameters governing the basis functions in a nonlinear fashion. The formulation in density-matrix terms enables one to overlook the individual configurational factors and LCAO coefficients and to operate with entire matrices constructed from them. There is a discussion of possible ways of solving the equations iteratively and of the area of application

  14. Correlation Coefficient between Dynamic Single Valued Neutrosophic Multisets and Its Multiple Attribute Decision-Making Method

    Directory of Open Access Journals (Sweden)

    Jun Ye

    2017-04-01

    Full Text Available Based on dynamic information collected from different time intervals in some real situations, this paper firstly proposes a dynamic single valued neutrosophic multiset (DSVNM to express dynamic information and operational relations of DSVNMs. Then, a correlation coefficient between DSVNMs and a weighted correlation coefficient between DSVNMs are presented to measure the correlation degrees between DSVNMs, and their properties are investigated. Based on the weighted correlation coefficient of DSVNMs, a multiple attribute decision-making method is established under a DSVNM environment, in which the evaluation values of alternatives with respect to attributes are collected from different time intervals and are represented by the form of DSVNMs. The ranking order of alternatives is performed through the weighted correlation coefficient between an alternative and the ideal alternative, which is considered by the attribute weights and the time weights, and thus the best one(s can also be determined. Finally, a practical example shows the application of the proposed method.

  15. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  16. Single- and cross-commodity discounting among cocaine addicts: the commodity and its temporal location determine discounting rate.

    Science.gov (United States)

    Bickel, Warren K; Landes, Reid D; Christensen, Darren R; Jackson, Lisa; Jones, Bryan A; Kurth-Nelson, Zeb; Redish, A David

    2011-09-01

    Intertemporal choice has provided important insights into understanding addiction, predicted drug-dependence status, and outcomes of treatment interventions. However, such analyses have largely been based on the choice of a single commodity available either immediately or later (e.g., money now vs. money later). In real life, important choices for those with addiction depend on making decisions across commodities, such as between drug and non-drug reinforcers. To date, no published study has systematically evaluated intertemporal choice using all combinations of a drug and a non-drug commodity. In this study, we examine the interaction between intertemporal choice and commodity type in the decision-making process of cocaine-dependent individuals. This study of 47 treatment-seeking cocaine addicts analyzes intertemporal choices of two commodities (equated amounts of cocaine and money), specifically between cocaine now vs. cocaine later (C-C), money now vs. money later (M-M), cocaine now vs. money later (C-M), and money now vs. cocaine later (M-C). Cocaine addicts discounted significantly more in the C-C condition than in M-M (P = 0.032), consistent with previous reports. Importantly, the two cross-commodity discounting conditions produced different results. Discounting in C-M was intermediate to the C-C and M-M rates, while the greatest degree of discounting occurred in M-C. These data indicate that the menu of commodities offered alter discounting rates in intertemporal choice and that the greatest rate is obtained when the drug is the later available commodity. Implications for understanding intertemporal choices and addiction are addressed.

  17. Effects of phylogenetic reconstruction method on the robustness of species delimitation using single-locus data.

    Science.gov (United States)

    Tang, Cuong Q; Humphreys, Aelys M; Fontaneto, Diego; Barraclough, Timothy G; Paradis, Emmanuel

    2014-10-01

    Coalescent-based species delimitation methods combine population genetic and phylogenetic theory to provide an objective means for delineating evolutionarily significant units of diversity. The generalised mixed Yule coalescent (GMYC) and the Poisson tree process (PTP) are methods that use ultrametric (GMYC or PTP) or non-ultrametric (PTP) gene trees as input, intended for use mostly with single-locus data such as DNA barcodes. Here, we assess how robust the GMYC and PTP are to different phylogenetic reconstruction and branch smoothing methods. We reconstruct over 400 ultrametric trees using up to 30 different combinations of phylogenetic and smoothing methods and perform over 2000 separate species delimitation analyses across 16 empirical data sets. We then assess how variable diversity estimates are, in terms of richness and identity, with respect to species delimitation, phylogenetic and smoothing methods. The PTP method generally generates diversity estimates that are more robust to different phylogenetic methods. The GMYC is more sensitive, but provides consistent estimates for BEAST trees. The lower consistency of GMYC estimates is likely a result of differences among gene trees introduced by the smoothing step. Unresolved nodes (real anomalies or methodological artefacts) affect both GMYC and PTP estimates, but have a greater effect on GMYC estimates. Branch smoothing is a difficult step and perhaps an underappreciated source of bias that may be widespread among studies of diversity and diversification. Nevertheless, careful choice of phylogenetic method does produce equivalent PTP and GMYC diversity estimates. We recommend simultaneous use of the PTP model with any model-based gene tree (e.g. RAxML) and GMYC approaches with BEAST trees for obtaining species hypotheses.

  18. Annoyance rate evaluation method on ride comfort of vehicle suspension system

    Science.gov (United States)

    Tang, Chuanyin; Zhang, Yimin; Zhao, Guangyao; Ma, Yan

    2014-03-01

    The existing researches of the evaluation method of ride comfort of vehicle mainly focus on the level of human feelings to vibration. The level of human feelings to vibration is influenced by many factors, however, the ride comfort according to the common principle of probability and statistics and simple binary logic is unable to reflect these uncertainties. The random fuzzy evaluation model from people subjective response to vibration is adopted in the paper, these uncertainties are analyzed from the angle of psychological physics. Discussing the traditional evaluation of ride comfort during vehicle vibration, a fuzzily random evaluation model on the basis of annoyance rate is proposed for the human body's subjective response to vibration, with relevant fuzzy membership function and probability distribution given. A half-car four degrees of freedom suspension vibration model is described, subject to irregular excitations from the road surface, with the aid of software Matlab/Simulink. A new kind of evaluation method for ride comfort of vehicles is proposed in the paper, i.e., the annoyance rate evaluation method. The genetic algorithm and neural network control theory are used to control the system. Simulation results are obtained, such as the comparison of comfort reaction to vibration environments between before and after control, relationship of annoyance rate to vibration frequency and weighted acceleration, based on ISO 2631/1(1982), ISO 2631-1(1997) and annoyance rate evaluation method, respectively. Simulated assessment results indicate that the proposed active suspension systems prove to be effective in the vibration isolation of the suspension system, and the subjective response of human being can be promoted from very uncomfortable to a little uncomfortable. Furthermore, the novel evaluation method based on annoyance rate can further estimate quantitatively the number of passengers who feel discomfort due to vibration. A new analysis method of vehicle

  19. Method for exploratory cluster analysis and visualisation of single-trial ERP ensembles.

    Science.gov (United States)

    Williams, N J; Nasuto, S J; Saddy, J D

    2015-07-30

    The validity of ensemble averaging on event-related potential (ERP) data has been questioned, due to its assumption that the ERP is identical across trials. Thus, there is a need for preliminary testing for cluster structure in the data. We propose a complete pipeline for the cluster analysis of ERP data. To increase the signal-to-noise (SNR) ratio of the raw single-trials, we used a denoising method based on Empirical Mode Decomposition (EMD). Next, we used a bootstrap-based method to determine the number of clusters, through a measure called the Stability Index (SI). We then used a clustering algorithm based on a Genetic Algorithm (GA) to define initial cluster centroids for subsequent k-means clustering. Finally, we visualised the clustering results through a scheme based on Principal Component Analysis (PCA). After validating the pipeline on simulated data, we tested it on data from two experiments - a P300 speller paradigm on a single subject and a language processing study on 25 subjects. Results revealed evidence for the existence of 6 clusters in one experimental condition from the language processing study. Further, a two-way chi-square test revealed an influence of subject on cluster membership. Our analysis operates on denoised single-trials, the number of clusters are determined in a principled manner and the results are presented through an intuitive visualisation. Given the cluster structure in some experimental conditions, we suggest application of cluster analysis as a preliminary step before ensemble averaging. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. An Analytical Method for Determining the Load Distribution of Single-Column Multibolt Connection

    Directory of Open Access Journals (Sweden)

    Nirut Konkong

    2017-01-01

    Full Text Available The purpose of this research was to investigate the effect of geometric variables on the bolt load distributions of a cold-formed steel bolt connection. The study was conducted using an experimental test, finite element analysis, and an analytical method. The experimental study was performed using single-lap shear testing of a concentrically loaded bolt connection fabricated from G550 cold-formed steel. Finite element analysis with shell elements was used to model the cold-formed steel plate while solid elements were used to model the bolt fastener for the purpose of studying the structural behavior of the bolt connections. Material nonlinearities, contact problems, and a geometric nonlinearity procedure were used to predict the failure behavior of the bolt connections. The analytical method was generated using the spring model. The bolt-plate interaction stiffness was newly proposed which was verified by the experiment and finite element model. It was applied to examine the effect of geometric variables on the single-column multibolt connection. The effects were studied of varying bolt diameter, plate thickness, and the plate thickness ratio (t2/t1 on the bolt load distribution. The results of the parametric study showed that the t2/t1 ratio controlled the efficiency of the bolt load distribution more than the other parameters studied.

  1. Comparing measurement error correction methods for rate-of-change exposure variables in survival analysis.

    Science.gov (United States)

    Veronesi, Giovanni; Ferrario, Marco M; Chambless, Lloyd E

    2013-12-01

    In this article we focus on comparing measurement error correction methods for rate-of-change exposure variables in survival analysis, when longitudinal data are observed prior to the follow-up time. Motivational examples include the analysis of the association between changes in cardiovascular risk factors and subsequent onset of coronary events. We derive a measurement error model for the rate of change, estimated through subject-specific linear regression, assuming an additive measurement error model for the time-specific measurements. The rate of change is then included as a time-invariant variable in a Cox proportional hazards model, adjusting for the first time-specific measurement (baseline) and an error-free covariate. In a simulation study, we compared bias, standard deviation and mean squared error (MSE) for the regression calibration (RC) and the simulation-extrapolation (SIMEX) estimators. Our findings indicate that when the amount of measurement error is substantial, RC should be the preferred method, since it has smaller MSE for estimating the coefficients of the rate of change and of the variable measured without error. However, when the amount of measurement error is small, the choice of the method should take into account the event rate in the population and the effect size to be estimated. An application to an observational study, as well as examples of published studies where our model could have been applied, are also provided.

  2. Critical examination of strain-rate sensitivity measurement by nanoindentation methods: Application to severely deformed niobium

    International Nuclear Information System (INIS)

    Alkorta, Jon; Martinez-Esnaola, Jose Manuel; Gil Sevillano, Javier

    2008-01-01

    Two different techniques for measuring the strain-rate sensitivity (SRS) exponent, m, of the power law relating the equivalent flow stress and the equivalent plastic strain rate are analyzed, paying special attention to the errors induced by the thermal drift rate and by the indentation-size effect. It is shown that the resolution and accuracy of indentation-creep tests are affected by these factors. An alternative method of m determination, the rate-jump test, avoids the influence of both the thermal drift and the indentation-size effect. Both methods are applied to the SRS determination of pure niobium samples with different plastic strain levels imparted by equal channel angular pressing. The results show the advantages of the rate-jump test. The observed strong dependence of the room temperature SRS of niobium on its dislocation density and on the strain rate are satisfactorily explained by the relative contributions of the Peierls stress and the dislocation density hardening to the flow stress of the samples

  3. Ultrafast modification of the spontaneous decay rate by plasmonic nanostructures: a step toward manipulation of a single atom

    International Nuclear Information System (INIS)

    Zavareian, N

    2014-01-01

    A controllable method for modifying spontaneous emission of an electric dipole located in close proximity to a plasmonic nanostructure is proposed. The nanostructure constructed of two triangular nanowires, in the form of a dimer, on a substrate in which the gallium film on the micrometer scale is the main layer. The results illustrate that phase transition of the gallium film from the α-crystalline to liquid phase leads to variation of the spectrum of radiative and nonradiative decay rates of the dipole where such a transition depends on parameters of the dipole, e.g. position, orientation and emission wavelength as well as on the nanostructure, e.g. shape and size of the dimer and also properties of the substrate. On the other hand, it is found that during phase transition modification of nanostructure resonances is negligible while the radiative decay rate changes. (letter)

  4. A precise evaluation of glomerular filtration rate (GFR) in two plasma samples following a single administration of 57Co-B12 vitamin

    International Nuclear Information System (INIS)

    Camargo, E.E.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E.; Papaleo Netto, M.; Carvalho, N.

    1974-01-01

    Through a logarithmic regression performed with the contings of 4 plasma samples withdrawn at 20,40,60 and 80 minutes after a venous injection of vitamin B 12 - 57 Co, the glomerular filtration-rate(GFR) in 11 patients, performing simultaneously the same study with EDTA- 51 Cr in 3 of them, is evaluated. The values obtained through the regression straight line are compared with those given by only 2 points, in the 6 possible combinations: 20 and 40 minutes, 20 and 60 minutes, 20 and 80 minutes, 40 and 60 minutes, 40 and 80 minutes, 60 and 80 minutes. The pair of points obtained at 20 and 80 minutes determined the straight line most similar to the logarithmic regression and as a simplification of the method, the withdraw of only 2 plasma samples, at and 80 minutes after a single injection of vitamin B 12 -57 Co is proposed [pt

  5. Automated bone removal in CT angiography : Comparison of methods based on single energy and dual energy scans

    NARCIS (Netherlands)

    van Straten, Marcel; Schaap, Michiel; Dijkshoorn, Marcel L.; Greuter, Marcel J.; van der Lugt, Aad; Krestin, Gabriel P.; Niessen, Wiro J.

    2011-01-01

    Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic

  6. A modified Gaussian integration method for thermal reaction rate calculation in U- and Pu-isotopes

    International Nuclear Information System (INIS)

    Bosevski, T.; Fredin, B.

    1966-01-01

    An advanced multi-group cell calculations a lot of data information is very often necessary, and hence the data administration will be elaborate, and the spectrum calculation will be time consuming. We think it is possible to reduce the necessary data information by using an effective reaction rate integration method well suited for U- and Pu-absorptions (author)

  7. Contamination rates of three urine-sampling methods to assess bacteriuria in pregnant women

    NARCIS (Netherlands)

    Schneeberger, Caroline; van den Heuvel, Edwin R.; Erwich, Jan Jaap H. M.; Stolk, Ronald P.; Visser, Caroline E.; Geerlings, Suzanne E.

    2013-01-01

    To estimate and compare contamination rates of three different urine-sampling methods in pregnant women to assess bacteriuria. In this cross-sectional study, 113 pregnant women collected three different midstream urine samples consecutively: morning (first void); midstream (void without further

  8. Exploring Top-Rated MBA Programs for Best Practices in Internationalizing Curricula: A Mixed Methods Study

    Science.gov (United States)

    Flores, Kelly A.

    2010-01-01

    To investigate if, and how, curriculum developers are incorporating opportunities to develop global competence into business curricula, the Exploratory Design: Taxonomy Development Model (Qualitative Emphasized) was conducted on top-rated MBA programs. This three-phase mixed methods approach revealed 11 global competencies (or taxonomies) and 84…

  9. Machine cost analysis using the traditional machine-rate method and ChargeOut!

    Science.gov (United States)

    E. M. (Ted). Bilek

    2009-01-01

    Forestry operations require ever more use of expensive capital equipment. Mechanization is frequently necessary to perform cost-effective and safe operations. Increased capital should mean more sophisticated capital costing methodologies. However the machine rate method, which is the costing methodology most frequently used, dates back to 1942. CHARGEOUT!, a recently...

  10. Effect of source, rate and method of nitrogen fertilizer application on ...

    African Journals Online (AJOL)

    Field trials were conducted for three years to determine the effects of source, rate and method of application of nitrogen fertilizer on maize yield at Ilora in the derived savanna zone and Ogbomoso in the southern guinea savanna zone of Nigeria. The nitrogen fertilizers (Granulated urea, Regular urea and Calcium ...

  11. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, P. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Halverson, M. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    This guidance document was prepared using the input from the meeting summarized in the draft CSI Roadmap to provide Building America research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America innovations arising in and/or stemming from codes, standards, and rating methods.

  12. A method for studying post-fledging survival rates using data from ringing recoveries

    NARCIS (Netherlands)

    Thomson, D.L.; Baillie, S.R.; Peach, W.J.

    1999-01-01

    We present a method for studying post-fledging survival rates from data on national ringing recoveries. The approach extends the classical two-age-class models of Brownie et al. (1985) to include a third age-class of birds ringed as nestlings. The models can incorporate age-class-specific and

  13. 24 CFR 985.3 - Indicators, HUD verification methods and ratings.

    Science.gov (United States)

    2010-04-01

    ... $5,000, expenses related to deductions from annual income, and other factors that affect the... rating for the indicator. The method for selecting the PHA's quality control sample under paragraphs (a), (b), (c) and (f) of this section must leave a clear audit trail that can be used to verify that the...

  14. Identification of strain-rate and thermal sensitive material model with an inverse method

    CERN Document Server

    Peroni, L; Peroni, M

    2010-01-01

    This paper describes a numerical inverse method to extract material strength parameters from the experimental data obtained via mechanical tests at different strain-rates and temperatures. It will be shown that this procedure is particularly useful to analyse experimental results when the stress-strain fields in the specimen cannot be correctly described via analytical models. This commonly happens in specimens with no regular shape, in specimens with a regular shape when some instability phenomena occur (for example the necking phenomena in tensile tests that create a strongly heterogeneous stress-strain fields) or in dynamic tests (where the strain-rate field is not constant due to wave propagation phenomena). Furthermore the developed procedure is useful to take into account thermal phenomena generally affecting high strain-rate tests due to the adiabatic overheating related to the conversion of plastic work. The method presented requires strong effort both from experimental and numerical point of view, an...

  15. Concurrent Driving Method with Fast Scan Rate for Large Mutual Capacitance Touch Screens

    Directory of Open Access Journals (Sweden)

    Mohamed Gamal Ahmed Mohamed

    2015-01-01

    Full Text Available A novel touch screen control technique is introduced, which scans each frame in two steps of concurrent multichannel driving and differential sensing. The proposed technique substantially increases the scan rate and reduces the ambient noise effectively. It is also extended to a multichip architecture to support excessively large touch screens with great scan rate improvement. The proposed method has been implemented using 0.18 μm CMOS TowerJazz process and tested with FPGA and AFE board connecting a 23-inch touch screen. Experimental results show a scan rate improvement of up to 23.8 times and an SNR improvement of 24.6 dB over the conventional method.

  16. An adaptation method to improve secret key rates of time-frequency QKD in atmospheric turbulence channels

    Science.gov (United States)

    Sun, Xiaole; Djordjevic, Ivan B.; Neifeld, Mark A.

    2016-03-01

    Free-space optical (FSO) channels can be characterized by random power fluctuations due to atmospheric turbulence, which is known as scintillation. Weak coherent source based FSO quantum key distribution (QKD) systems suffer from the scintillation effect because during the deep channel fading the expected detection rate drops, which then gives an eavesdropper opportunity to get additional information about protocol by performing photon number splitting (PNS) attack and blocking single-photon pulses without changing QBER. To overcome this problem, in this paper, we study a large-alphabet QKD protocol, which is achieved by using pulse-position modulation (PPM)-like approach that utilizes the time-frequency uncertainty relation of the weak coherent photon state, called here TF-PPM-QKD protocol. We first complete finite size analysis for TF-PPM-QKD protocol to give practical bounds against non-negligible statistical fluctuation due to finite resources in practical implementations. The impact of scintillation under strong atmospheric turbulence regime is studied then. To overcome the secure key rate performance degradation of TF-PPM-QKD caused by scintillation, we propose an adaptation method for compensating the scintillation impact. By changing source intensity according to the channel state information (CSI), obtained by classical channel, the adaptation method improves the performance of QKD system with respect to the secret key rate. The CSI of a time-varying channel can be predicted using stochastic models, such as autoregressive (AR) models. Based on the channel state predictions, we change the source intensity to the optimal value to achieve a higher secret key rate. We demonstrate that the improvement of the adaptation method is dependent on the prediction accuracy.

  17. Ultrasonic 3-D Vector Flow Method for Quantitative In Vivo Peak Velocity and Flow Rate Estimation.

    Science.gov (United States)

    Holbek, Simon; Ewertsen, Caroline; Bouzari, Hamed; Pihl, Michael Johannes; Hansen, Kristoffer Lindskov; Stuart, Matthias Bo; Thomsen, Carsten; Nielsen, Michael Bachmann; Jensen, Jorgen Arendt

    2017-03-01

    Current clinical ultrasound (US) systems are limited to show blood flow movement in either 1-D or 2-D. In this paper, a method for estimating 3-D vector velocities in a plane using the transverse oscillation method, a 32×32 element matrix array, and the experimental US scanner SARUS is presented. The aim of this paper is to estimate precise flow rates and peak velocities derived from 3-D vector flow estimates. The emission sequence provides 3-D vector flow estimates at up to 1.145 frames/s in a plane, and was used to estimate 3-D vector flow in a cross-sectional image plane. The method is validated in two phantom studies, where flow rates are measured in a flow-rig, providing a constant parabolic flow, and in a straight-vessel phantom ( ∅=8 mm) connected to a flow pump capable of generating time varying waveforms. Flow rates are estimated to be 82.1 ± 2.8 L/min in the flow-rig compared with the expected 79.8 L/min, and to 2.68 ± 0.04 mL/stroke in the pulsating environment compared with the expected 2.57 ± 0.08 mL/stroke. Flow rates estimated in the common carotid artery of a healthy volunteer are compared with magnetic resonance imaging (MRI) measured flow rates using a 1-D through-plane velocity sequence. Mean flow rates were 333 ± 31 mL/min for the presented method and 346 ± 2 mL/min for the MRI measurements.

  18. An optical measurement method for the simultaneous assessment of respiration and heart rates in preterm infants

    Science.gov (United States)

    Marchionni, P.; Scalise, L.; Ercoli, I.; Tomasini, E. P.

    2013-12-01

    Many conventional medical monitoring devices, while not technically invasive, are nevertheless obtrusive insofar as they require contact with the patient. This obtrusiveness sometimes poses problems in daily clinical practice. The need for contact with electrodes or transducers is particularly relevant in the case of patients recovering in intensive care units where continuous monitoring is required, in turn requiring continuous direct transducer contact for prolonged periods. Among the many physiological parameters commonly acquired, the respiratory and the cardiac rates of the patients are of primary importance. Typically these two parameters are measured respectively using spirometry and electrocardiography (ECG), both involving obtrusive measurement systems requiring contact with the patient with an air conduit and electrodes. This paper presents an optical measurement method for the simultaneous assessment of respiration and heart rates based on the measurement of the chest wall movements, associated with inspiratory/expiratory activities of the lungs and by the mechanical pumping action of the heart. The measurement method has been adapted for use with preterm infants and it has been applied to 55 patients recovering in a Neonatal Intensive Care Unit. The method is based on the use of a laser Doppler vibrometer (LDVi) pointed at the left, ventral thoracic surface of the patient. LDVi-based measures of respiration and heart rate have been simultaneously acquired for each patient, in parallel with the same quantities acquired using conventional reference instrumentation (flow-meter and ECG) for comparison purposes. Results show that for respiration rate, differences with respect to the spirometer data are instrument, the simultaneous measurement of respiration and heart rates, thus reducing the burden of the number of electrodes, transducers, and other instrumentation that must be applied to the patient—a consideration that is particularly important in the

  19. Open charcoal chamber method for mass measurements of radon exhalation rate from soil surface

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Kovler, Konstantin; Miklyaev, Peter

    2016-01-01

    Radon exhalation rate from the soil surface can serve as an important criterion in the evaluation of radon hazard of the land. Recently published international standard ISO 11665-7 (2012) is based on the accumulation of radon gas in a closed container. At the same time since 1998 in Russia, as a part of engineering and environmental studies for the construction, radon flux measurements are made using an open charcoal chamber for a sampling duration of 3–5 h. This method has a well-defined metrological justification and was tested in both favorable and unfavorable conditions. The article describes the characteristics of the method, as well as the means of sampling and measurement of the activity of radon absorbed. The results of the metrological study suggest that regardless of the sampling conditions (weather, the mechanism and rate of radon transport in the soil, soil properties and conditions), uncertainty of method does not exceed 20%, while the combined standard uncertainty of radon exhalation rate measured from the soil surface does not exceed 30%. The results of the daily measurements of radon exhalation rate from the soil surface at the experimental site during one year are reported. - Highlights: • Radon exhalation rate from the soil surface area of 32 cm 2 can be measured at level of 10 mBq/(m 2 s) at the uncertainty ≤30%. • The method has a metrological justification. • No need to consider climate conditions, soil properties and conditions, mechanism and rate of radon transport in the soil.

  20. Method and apparatus for obtaining enhanced production rate of thermal chemical reactions

    Science.gov (United States)

    Tonkovich, Anna Lee Y [Pasco, WA; Wang, Yong [Richland, WA; Wegeng, Robert S [Richland, WA; Gao, Yufei [Kennewick, WA

    2003-04-01

    The present invention is a method and apparatus (vessel) for providing a heat transfer rate from a reaction chamber through a wall to a heat transfer chamber substantially matching a local heat transfer rate of a catalytic thermal chemical reaction. The key to the invention is a thermal distance defined on a cross sectional plane through the vessel inclusive of a heat transfer chamber, reaction chamber and a wall between the chambers. The cross sectional plane is perpendicular to a bulk flow direction of the reactant stream, and the thermal distance is a distance between a coolest position and a hottest position on the cross sectional plane. The thermal distance is of a length wherein the heat transfer rate from the reaction chamber to the heat transfer chamber substantially matches the local heat transfer rate.