  1. Touch sensitivity with sterile standard surgical gloves and single-use protective gloves.

    Science.gov (United States)

    Tiefenthaler, W; Gimpl, S; Wechselberger, G; Benzer, A

    2006-10-01

    The purpose of this study was to evaluate touch sensitivity and static two-point discrimination of the dominant index and middle finger in 20 anaesthetists wearing no gloves, single-use protective gloves or sterile standard surgical gloves. Semmes-Weinstein filaments were used to measure cutaneous pressure thresholds, and a Two-Point-Discriminator to estimate static two-point discrimination. Wearing gloves significantly reduced touch sensitivity (p gloves. The results of our study suggest that the additional cost of sterile standard surgical gloves can not be justified in terms of touch sensitivity.

  2. Single patient doses of {sup 99m}Tc-HDP: Assessment of radiochemical purity, sterility and extractables from a polypropylene syringe over six hours

    Energy Technology Data Exchange (ETDEWEB)

    Parkes, S.L.; Varelis, P. [St George Hospital, Kogarah, NSW (Australia). Department of Nuclear Medicine

    1997-12-01

    Full text: The purpose of this investigation was to determine the radiochemical purity (RCP), sterility and extractables for {sup 99m}Tc oxidronate ({sup 99m}Tc-HDP) stored in polypropylene syringes over < six-hour period. The radiochemical purity was determined using a two-strip ITLC procedure, performed at time 0, 1, 2, 4, 6 hours. The sterility and endotoxin levels were tested by a NATA accredited laboratory, after allowing the radiopharmaceutical to stand at room temperature for six hours in the syringes. Plasticisers and other likely compounds that could be extracted from the syringes into the aqueous solution were determined by high pressure liquid chromatography (HPLC) diode array detection. This analysis involved shaking normal saline in a syringe over night and then injecting an aliquot of this solution onto a C18 analytical column and monitoring the effluent at 200 and 253 nm. The radiochemical purity of {sup 99m}Tc-HDP did not significantly change over the course of the study and remained above the recommended RCP for this radiopharmaceutical. Furthermore, at six hours the RCP of {sup 99m}Tc-HDP stored in both the manufacturer`s vial and a syringe were identical. Sterility testing of {sup 99m}Tc-HDP stored in syringes showed no microbial growth and less than 10 endotoxin units/mL (pass). The HPLC analysis did not show the presence of any extraneous compounds in the aqueous solution. Single patient doses of {sup 99m}Tc-HDP stored in polypropylene syringes over a six-hour period fulfill all the quality control requirements for administration to humans.

  3. Access to sterile syringes for injecting drug users in New York City: politics and perception (1984-2010).

    Science.gov (United States)

    Heller, Daliah; Paone, Denise

    2011-01-01

    In the United States, political and social environments have shaped public health response to injecting drug use, and New York City represents a salient example. The history of "harm reduction" in New York City is characterized within changing historical periods and in relation to the actions of stakeholders. The expansion is traced over four periods: (i) 1984-1989: emergence, activism, and science; (ii) 1990-1994 reckoning: syringe exchange legislation and consolidation; (iii) 1995-1999: bureaucratization, opposition, and challenges to institutional control; and (iv) 2000-2010 revitalization: expansion of syringe access and harm reduction. It is clear from this review that the leadership of activism and the work of advocates catalyzed syringe access policy and practice. Without this "push," it is unlikely that New York City would have experienced the dramatic decline in HIV infection among drug injectors in the 1990s. Second, successful arguments for expanding syringe access in New York City were based on the high HIV/AIDS infection rates. Thus, program developments were advocated as HIV prevention interventions, rather than as expanded services for addressing broader health and social issues of injecting drug use.

  4. Stability of 10 mg/mL cefuroxime solution for intracameral injection in commonly used polypropylene syringes and new ready-to-use cyclic olefin copolymer sterile vials using the LC-UV stability-indicating method.

    Science.gov (United States)

    Feutry, Frédéric; Simon, Nicolas; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Décaudin, Bertrand; Labalette, Pierre; Odou, Pascal

    2016-01-01

    Injecting intracameral cefuroxime has been found beneficial in reducing the risk of postoperative endophthalmitis but its use has been limited through a lack of approved marketing and of ready-to-use single-units as well as the problem of aseptic compounding. Our aim was to assess a new automated primary packaging system which should ensure a higher level of sterility, thanks to its closed, sterile, ready-to-use polymer vial called "Crystal® vial". The chemical stability of a 10 mg/mL cefuroxime solution was compared in 1 mL Crystal® vials and 1 mL Luer-lock polypropylene syringes (actual reference) to eliminate any potential and specific interactions with its cyclic olefin copolymer (COC) body and elastomer stopper. Cefuroxime solution was introduced into vials and syringes and stored at -20 °C, +5 °C and +25°C/60% Relative Humidity. Cefuroxime concentration and the relative amount of the main degradation product (descarbamoyl-cefuroxime) were both determined by an HPLC/UV method indicating stability. Solutions were considered steady if the concentration remained at over 90% of the initial value. In the adapted storage conditions, the evolution of osmolality, pH and sterility was assessed. Stability profiles were identical between vials and syringes in all storage and temperature conditions. The solution was stable (cefuroxime concentration, pH and osmolality) and still sterile for 365 days at -20°C. The concentration fell below 90% after 21 days at +5 °C and after 16 h at +25°C/60%s relative humidity. The COC and thermoplastic elastomer of the vials had no impact on the degradation process confirming its possible use for a ready-to-use cefuroxime solution single-unit dose.

  5. Randomized, community-based pharmacy intervention to expand services beyond sale of sterile syringes to injection drug users in pharmacies in New York City.

    Science.gov (United States)

    Crawford, Natalie D; Amesty, Silvia; Rivera, Alexis V; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M

    2013-09-01

    Structural interventions may help reduce racial/ethnic disparities in HIV. In 2009 to 2011, we randomized pharmacies participating in a nonprescription syringe access program in minority communities to intervention (pharmacy enrolled and delivered HIV risk reduction information to injection drug users [IDUs]), primary control (pharmacy only enrolled IDUs), and secondary control (pharmacy did not engage IDUs). Intervention pharmacy staff reported more support for syringe sales than did control staff. An expanded pharmacy role in HIV risk reduction may be helpful.

  6. Syringe sociology.

    Science.gov (United States)

    Vitellone, Nicole

    2015-06-01

    In this article I consider the impact of social epistemologies for understanding the object of the syringe. My aim is to examine the process through which the syringe transforms from an injecting device to a tool of social and political inquiry. Paying particular attention to the uses of Foucault, Becker, Bourdieu, Freud and Latour in empirical studies of injecting heroin use, I examine the sociology of the syringe through the lens of habit and habitus, discourse and deviance, mourning and melancholia, attachment and agencement. In pursuing the theory behind the object my goal is to address a sociological object in the making. In so doing I show how the syringe has been significant for social research, social theory, and sociology. It is the difference the object makes that this article seeks to describe. In tracing the epistemology of the syringe I show how the object is important not just for knowledge of addiction but sociology itself. © London School of Economics and Political Science 2015.

  7. Lower syringe sharing and re-use after syringe legalization in Rhode Island.

    Science.gov (United States)

    Rich, Josiah D; Hogan, Joseph W; Wolf, Francis; DeLong, Allison; Zaller, Nickolas D; Mehrotra, Meenakshi; Reinert, Steven

    2007-07-10

    Increased access to sterile syringes reduces the transmission of HIV, viral hepatitis and other infectious diseases, without increasing injection drug use. In Rhode Island, in 2000, syringes were legalized to reduce spread of disease but remained outlawed in Massachusetts until 2006. Drug users undergoing inpatient detoxification in Rhode Island and Massachusetts were surveyed about their syringe usage between October 2001 and August 2003. Two hundred forty-seven Rhode Island, and 226 Massachusetts inpatients completed surveys. Of these, 61% (n=151) from Rhode Island and 46% (n=105) from Massachusetts reported injecting within 6 months. Respondents from Rhode Island reported reusing a syringe in the last 30 days less often than Massachusetts respondents (0.35 versus 0.50; 95% CI on difference 0.01-0.29). Syringe re-use and sharing among drug injectors in Rhode Island was markedly lower than in Massachusetts. This difference is attributed at least in part to the legalization of non-prescription sterile syringes in Rhode Island in 2000. Laws and policies that increase legal syringe availability can decrease injection related transmission of HIV and other infectious diseases.

  8. Injection drug users report good access to pharmacy sale of syringes.

    Science.gov (United States)

    Reich, Wendy; Compton, Wilson M; Horton, Joeseph C; Cottler, Linda B; Cunningham-Williams, Renee M; Booth, Robert; Singer, Merrill; Leukefeld, Carl; Fink, Joseph; Stopka, Tom J; Corsi, Karen Fortuin; Tindall, Michelle Staton

    2002-01-01

    To examine injection drug users (IDUs) opinions and behavior regarding purchase of sterile syringes from pharmacies. Focus groups. Urban and rural sites in Colorado, Connecticut, Kentucky, and Missouri. Eight focus groups, with 4 to 15 IDU participants per group. Transcripts of focus group discussions were evaluated for common themes by the authors and through the use of the software program NUD*IST. Knowledge of human immunodeficiency virus (HIV), pharmacy use, barriers to access from pharmacies, high-risk and risk-reducing behavior, and rural/urban difference. Almost all participants knew the importance of using sterile syringes for disease prevention and reported buying syringes from pharmacies more than from any other source. Two IDUs believed pharmacists knew the syringes were being used for injecting drugs and perceived pharmacists' sales of syringes to be an attempt to contribute to HIV prevention. Most IDUs reported that sterile syringes were relativity easy to buy from pharmacies, but most also reported barriers to access, such as having to buy in packs of 50 or 100, being made to sign a book, having to make up a story about being diabetic, or having the feeling that the pharmacists were demeaning them. While the majority of IDUs reported properly cleaning or not sharing syringes and safely disposing of them, others reported inadequate cleaning of syringes and instances of sharing syringes or of improper disposal. There were few differences in IDUs' reported ability to buy syringes among states or between urban and rural sites, although the data suggest that IDUs could buy syringes more easily in the urban settings. For the most part, participants understood the need for sterile syringes in order to protect themselves from HIV, hepatitis B virus, and hepatitis C virus and saw pharmacies as the best source of sterile syringes. Although these data are not generalizable, they suggest that pharmacists can and do serve as HIV-prevention service providers in

  9. Need for needle and syringe programmes in Africa | Derrick | African ...

    African Journals Online (AJOL)

    A narrative review was conducted, drawing on peer reviewed literature and relevant grey literature on injecting drug use in African countries and ethical dilemmas facing harm reduction especially the provision of sterile needles and syringes to injecting drug users. This review aimed at highlighting evidence and the ...

  10. Safer Disposable Syringe

    OpenAIRE

    Swann, David

    2013-01-01

    Injections are one of the most common healthcare procedures performed in the world and the most deadly. Each year 16 billion injections are delivered using a pre-used syringe. This action kills 1.3 million patients and accounts for 26-million life years lost and 32% of all new Hepatitis B cases. To prevent such violations the auto-destruct syringe was introduced in 1986. This device has since become a prerequisite tool for immunization programmes (95%) but only used for 5% of all curative inj...

  11. Patient Safety Threat - Syringe Reuse

    Science.gov (United States)

    ... to Prevent HAIs HICPAC One & Only Campaign A Patient Safety Threat – Syringe Reuse Recommend on Facebook Tweet Share Compartir Important ... due to syringe reuse by your healthcare provider. Patients need to be aware of a very serious ...

  12. Syringe-injectable electronics.

    Science.gov (United States)

    Liu, Jia; Fu, Tian-Ming; Cheng, Zengguang; Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M

    2015-07-01

    Seamless and minimally invasive three-dimensional interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating the syringe injection (and subsequent unfolding) of sub-micrometre-thick, centimetre-scale macroporous mesh electronics through needles with a diameter as small as 100 μm. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with >90% device yield. We demonstrate several applications of syringe-injectable electronics as a general approach for interpenetrating flexible electronics with three-dimensional structures, including (1) monitoring internal mechanical strains in polymer cavities, (2) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (3) in vivo multiplexed neural recording. Moreover, syringe injection enables the delivery of flexible electronics through a rigid shell, the delivery of large-volume flexible electronics that can fill internal cavities, and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics.

  13. Syringe injectable electronics

    Science.gov (United States)

    Hong, Guosong; Zhou, Tao; Jin, Lihua; Duvvuri, Madhavi; Jiang, Zhe; Kruskal, Peter; Xie, Chong; Suo, Zhigang; Fang, Ying; Lieber, Charles M.

    2015-01-01

    Seamless and minimally-invasive three-dimensional (3D) interpenetration of electronics within artificial or natural structures could allow for continuous monitoring and manipulation of their properties. Flexible electronics provide a means for conforming electronics to non-planar surfaces, yet targeted delivery of flexible electronics to internal regions remains difficult. Here, we overcome this challenge by demonstrating syringe injection and subsequent unfolding of submicrometer-thick, centimeter-scale macroporous mesh electronics through needles with a diameter as small as 100 micrometers. Our results show that electronic components can be injected into man-made and biological cavities, as well as dense gels and tissue, with > 90% device yield. We demonstrate several applications of syringe injectable electronics as a general approach for interpenetrating flexible electronics with 3D structures, including (i) monitoring of internal mechanical strains in polymer cavities, (ii) tight integration and low chronic immunoreactivity with several distinct regions of the brain, and (iii) in vivo multiplexed neural recording. Moreover, syringe injection enables delivery of flexible electronics through a rigid shell, delivery of large volume flexible electronics that can fill internal cavities and co-injection of electronics with other materials into host structures, opening up unique applications for flexible electronics. PMID:26053995

  14. Aquagenic syringeal acrokeratoderma

    Directory of Open Access Journals (Sweden)

    Belkiz Uyar

    2014-01-01

    Full Text Available Aquagenic syringeal acrokeratoderma is a rare, transient, and usually bilaterally symmetric, palmoplantar keratoderma. Patients complain of tingling and pain in the hands starting a few minutes after exposure to water and lasting for 20-30 minutes after removal. Clinically, there is marked wrinkling with edematous white papules on the palms or, less often, the soles. We present the case of a 21-year-old woman who used spironolactone for polycystic ovary syndrome and had similar clinical features 2 weeks later, after withdrawing the drug.

  15. Spacecraft sterilization.

    Science.gov (United States)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  16. Experiments with Disposable Hypodermic Syringes.

    Science.gov (United States)

    Clayton, G. T.; And Others

    1988-01-01

    Lists five experiments or demonstrations involving hypodermic syringes. The titles of experiments are Boyle's Law, Charles' Law, Atmospheric Pressure, Expansion of Gases, and Boiling at Reduced Pressure. Provides a list of materials, the typical data, and graphs where appropriate. (YP)

  17. A Comparison of Protein Stability in Prefillable Syringes Made of Glass and Plastic.

    Science.gov (United States)

    Waxman, Lloyd; Vilivalam, Vinod D

    2017-01-01

    The development of protein therapeutics requires stabilization of these labile molecules during shipment and storage. Biologics, particularly monoclonal antibodies, are frequently packaged at high concentration in prefillable syringes traditionally made of glass. However, some biologics are unstable in glass due to sensitivity to silicone oil, tungsten, glue, or metal ions. Syringes made from the plastic cyclic olefin polymer, Daikyo Crystal Zenith® (CZ), with a Flurotec-laminated piston, have none of these issues. This study compared the stability of several proteins including biotherapeutics when stored up to 14 months at 5 °C and 25 °C in prefillable siliconized syringes made of glass or silicone oil-free CZ syringes, and when subjected to mild agitation by end-over-end rotation at room temperature. At each time point, proteins were analyzed by several techniques including turbidity, size exclusion high-performance liquid chromatography, reversed phase high-performance liquid chromatography, ion-exchange chromatography, electrophoresis, and light scattering to monitor changes in aggregation and degradation. The results show that proteins have comparable stability when stored in glass syringes or in syringes made of CZ sterilized by E-beam or autoclave. In addition, proteins stressed by agitation were generally more stable and aggregated less in syringes made of CZ than in ones made of glass. LAY ABSTRACT: Biotherapeutic protein drugs such as monoclonal antibodies are frequently packaged at high concentration in prefillable syringes, which allows the drug to be directly administered by the patient or caregiver. Protein drugs, or biologics, can be unstable, and may aggregate, particularly when shaken. These aggregates can be immunogenic, stimulating the body's immune system to produce antibodies that can reduce the drug's efficacy. Although prefillable syringes are traditionally made of glass, some biologics are unstable in glass syringes due to the presence of

  18. Reversible Sterilization

    Science.gov (United States)

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  19. Commentary on Vorobjov et al., "Comparison of injection drug users who obtain syringes from pharmacies and syringe exchange programs in Tallinn, Estonia"

    Directory of Open Access Journals (Sweden)

    Werb Daniel

    2009-01-01

    Full Text Available Abstract Recent data suggest that globally, between 5% and 10% of all new HIV cases are the result of unsafe injecting practices, and experts agree that reducing these practices is key to tackling the spread of HIV. And yet, despite the overwhelming evidence that providing sterile syringes to injection drug users (IDU through syringe exchange programs (SEPs or other means is an effective way of reducing HIV transmission among high-risk subpopulations, IDU in most settings still do not have access to sterile injecting equipment or if they do, access remains too restricted to effectively reduce the risk of HIV transmission. Vorobjov and colleagues have presented in this journal an interesting and timely study from Estonia comparing individuals who obtain syringes from SEPs and those who obtain syringes from pharmacies. As the authors point out, Estonia faces an unacceptably high HIV incidence rate of 50 new HIV cases per 100,000, this rate driven primarily by injection drug use. As such, the authors argue that Estonia's SEP network does not have the capacity to serve a growing IDU population at risk of transmitting HIV and pharmacy dispensation of clean syringes may be one potential approach to decreasing syringe sharing among high-risk injectors. It may be overly optimistic to consider the impact of higher threshold interventions such as pharmacy-based SEPs, given that IDU populations that engage in HIV risk behaviours such as syringe sharing are often hidden or hard to reach. Despite the need for a cautious approach, however, the findings presented by Vorobjov et al. may chart one potential course towards a more comprehensive societal response to reducing the health harms associated with injection drug use.

  20. Sterilization System

    Science.gov (United States)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  1. The sterilization efficacy of reprocessed single use diathermy pencils La eficacia de la esterilización del bisturí eléctrico tipo lápiz de uso único reprocesados Eficácia da esterilização de canetas de bisturi elétrico de uso único reprocessadas

    Directory of Open Access Journals (Sweden)

    Simone Batista Neto

    2010-02-01

    Full Text Available In Brazil, single use diathermy pencils (SUDP are among the most common reused devices. This study assesses the sterilization efficacy of reprocessing SUDP using two cleansing methods (manual or automated, followed by one of three of the low-temperature sterilization methods: Hydrogen Peroxide Plasma (HPP, Ethylene Oxide (ETO or Low-Temperature Steam Formaldehyde (LTSF. The sample was composed of 360 SUDP after their first use. The probability of sterilization failure was estimated considering the number of positive microbiological results obtained by cultures of the studied devices. The overall sterilization failure probability for SUDP was 0.26. The sterilization method, which presented the lowest failure probability was the LTSF (0.01, followed by ETO (0.21 and HPP (0.56. Automated cleansing obtained a better result than manual cleansing. This trial demonstrated that the probability of sterilization in reprocessed SUDP is highly dependent on both the type of cleansing and the sterilization method applied.En Brasil, el bisturí eléctrico tipo lápiz de uso único (BETLUU es uno de los artículos más comúnmente reutilizados. El presente estudio evaluó la eficacia de la esterilización de BETLUUs reprocesados, utilizando dos métodos de limpieza (manual y automatizado, seguidos de uno de los siguientes métodos de esterilización: plasma de peróxido de hidrogeno (PPH, óxido de etileno (OE o vapor de baja temperatura de formaldehído (VBTF. Fueron analizadas 360 BETLUUs después de su primera utilización. La probabilidad de falla de esterilización fue estimada considerando el número de resultados positivos de cultura de los dispositivos estudiados. La probabilidad general de falla de esterilización de los BETLUUs fue de 0,26. La menor probabilidad de falla fue obtenida con el VBTF (0,01, seguida del OE (0,21 y del PPH (0,56. La limpieza automatizada obtuvo mejores resultados cuando comparada a la limpieza manual. El presente estudio

  2. Sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, J. [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics, Johannes Gutenberg University, 55099 Mainz (Germany); Machado, P. A. N., E-mail: pedro.machado@uam.es [Departamento de Física Teórica, Universidad Autónoma de Madrid, Cantoblanco E-28049 Madrid (Spain); Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid (Spain); Maltoni, M. [Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid (Spain); Schwetz, T. [Institute for Nuclear Physics, Karlsruhe Institute of Technology (KIT), Postfach 3640, 76021 Karlsruhe (Germany)

    2016-06-21

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  3. Evaluation of single-use reprocessed laparoscopic instrument sterilization Evaluación de la esterilidad del instrumental laparoscópico descartable reprocesado Avaliação da esterilidade do instrumental laparoscópico de uso único reprocessado

    Directory of Open Access Journals (Sweden)

    Cristiane de Lion Botero Couto Lopes

    2011-04-01

    Full Text Available This experimental, comparative, laboratory study evaluated the effectiveness of the sterilization of single-use laparoscopic instruments - SULIs (grasper, dissector, scissors, Veress needle and electrosurgical probe system, after contamination-challenge with bacterial spores and sheep blood, and compared the results of the sterilization tests with those of the equivalent reusable instruments. The cleaning methods used were; ultrasonic washer with pulsatile water jet and enzymatic detergent, manual cleaning, cleaning with pressurized water and rinsing. The SULIs were sterilized with ethylene oxide and the reusable instruments in an autoclave. Sterility tests showed 100% negative results for recovery of contaminate microorganisms in both groups. It was concluded that, regarding the sterilization, that it is possible to reprocess SULIs.Se trata de un estudio, experimental, de laboratorio y comparativo, que evaluó la eficacia de la esterilidad de los instrumentos laparoscópicos de uso único(ILUU: grasper, disector, tijera, aguja de Veres y el sistema de sonda electroquirúrgica, después de "contaminación desafío" con esporas bacterianas y sangre de carnero; los resultados de las pruebas de esterilidad fueron comparados con los de los instrumentos equivalentes "permanentes". Para efectuar la limpieza se utilizó: lavadora ultrasónica con chorro pulsante y detergente enzimático, limpieza manual, agua bajo presión y enjuague. Los ILUU fueron esterilizados con óxido de etileno, los instrumentos "permanentes" en autoclave. Las pruebas de esterilidad mostraron resultados 100% negativos para la recuperación de los microorganismos contaminantes en los dos grupos. Se concluye que, en relación al alcance de la esterilidad, es posible reprocesar los ILUU.O presente estudo, experimental, laboratorial e comparativo, teve como objetivo avaliar a eficácia da esterilidade dos instrumentos laparoscópicos de uso único (ILUU: grasper, dissector, tesoura

  4. Legal syringe purchases by injection drug users, Brooklyn and Queens, New York City, 2000-2001.

    Science.gov (United States)

    Des Jarlais, Don C; McKnight, Courtney; Friedmann, Patricia

    2002-01-01

    To assess preliminary results of the Expanded Syringe Access Demonstration Program (ESAP) in New York City. Temporal trends of pharmacy use among injection drug users (IDUs) in Brooklyn and Queens were analyzed from December 2000 through December 2001. Brooklyn and Queens, New York City. PARTIPANTS: IDUs. Attempts to purchase syringes from pharmacies and success in doing so. Of the 1,072 IDUs interviewed from December 2000 through December 2001, the majority were daily heroin injectors, but there was also substantial speedball and cocaine injection. There was a clear increase over time in both the percentage of subjects who attempted to purchase syringes in pharmacies and in the percentage who successfully purchased syringes. Among IDUs interviewed 4 or more months after ESAP began, large majorities of those who attempted to purchase syringes were successful in doing so. No differences in use of ESAP by IDUs were identified in Brooklyn versus Queens: 27% of IDUs interviewed in Queens reported that they had attempted to purchase syringes in pharmacies versus 28% in Brooklyn. Persons who reported injecting on a daily or more frequent basis were more likely to have attempted pharmacy purchases than persons who reported injecting less frequently, 32% versus 21%. The ESAP program has led to an increase in the use of pharmacies as sources of sterile injection equipment among IDUs in New York City. The extent to which pharmacies become an important source of sterile injection equipment and the effect of legal pharmacy sales on risk behaviors for human immunodeficiency virus (HIV) infection remain to be determined.

  5. Negotiating access: Social barriers to purchasing syringes at pharmacies in Tijuana, Mexico

    Science.gov (United States)

    Davidson, Peter J.; Lozada, Remedios; Rosen, Perth C.; Macias, Armando; Gallardo, Manuel; Pollini, Robin A.

    2012-01-01

    Background One common public health response to the emergence of HIV has been the provision of sterile syringes to people who inject drugs. In Mexico specialized syringe exchanges are rare, and the sale of needles through pharmacies is often the only way people who inject drugs can obtain sterile syringes. However, people who inject drugs in Tijuana, Mexico report considerable social barriers to successfully purchasing syringes at pharmacies. Methods Between October 2008 and March 2009 we conducted seven in-depth focus groups with 47 people who inject drugs in Tijuana, Mexico. Focus group transcripts were analysed using a descriptive and thematic approach rooted in grounded theory. Results We found that injectors offered a number of explanations for why pharmacies were reluctant to sell them syringes, including fear of police; attitudes toward drug use; fear of stereotypical drug user behaviour such as petty theft, violence, or distressing behaviour; and related fears that an obvious drug using clientèle would drive away other customers. Injectors described a range of ways of attempting to re-frame or negotiate interactions with pharmacy staff so that these and related concerns were ameliorated. These included tactics as simple as borrowing cleaner clothing, through to strategies for becoming ‘known’ to pharmacy staff as an individual rather than as a member of a stigmatized group. Conclusion Increasing the ability of pharmacy staff and people who inject drugs to successfully negotiate syringe sales are highly desirable. Interventions designed to improve this likelihood need to capitalize on existing solutions developed ad-hoc by people who inject drugs and pharmacy staff, and should focus on broadening the range of ‘identities’ which pharmacy staff are able to accept as legitimate customers. Approaches to achieve this end might include sensitizing pharmacy staff to the needs of people who inject drugs; facilitating individual drug users meeting individual

  6. Hypertensive Crisis During Norepinephrine Syringe Exchange

    NARCIS (Netherlands)

    Snijder, Roland A; Knape, Johannes T A; Egberts, Toine C G|info:eu-repo/dai/nl/162850050; Timmerman, Annemoon M D E

    2017-01-01

    A 67-year critically ill patient suffered from a hypertensive crisis (200 mm Hg) because of a norepinephrine overdose. The overdose occurred when the clinician exchanged an almost-empty syringe and the syringe pump repeatedly reported an error. We hypothesized that an object between the plunger and

  7. Hypertensive Crisis During Norepinephrine Syringe Exchange

    NARCIS (Netherlands)

    Snijder, Roland A; Knape, Johannes T A|info:eu-repo/dai/nl/071757481; Egberts, Toine C G|info:eu-repo/dai/nl/162850050; Timmerman, Annemoon M D E

    A 67-year critically ill patient suffered from a hypertensive crisis (200 mm Hg) because of a norepinephrine overdose. The overdose occurred when the clinician exchanged an almost-empty syringe and the syringe pump repeatedly reported an error. We hypothesized that an object between the plunger and

  8. Reutilização simulada de produtos médico-hospitalares de uso único, submetidos à esterilização com óxido de etileno Simulated reuse of single use medical devices submitted to ethylene oxide sterilization

    Directory of Open Access Journals (Sweden)

    Mônica Valero da Silva

    2005-06-01

    bacterial endotoxin (200 EU/device. The B. subtilis contaminated specimen samples had been washed, rinsed, dried and sterilized with ETO/CFC 12:88. Those contaminated with bacterial endotoxin had been submitted to drying, repacking and sterilization. After each cycle, ten units, contaminated with B. subtilis, had been evaluated by microbial counting test, sterility test, in vitro cytotoxicity and scanning electron microscopy. Those contaminated with bacterial endotoxin, three units of each specimen sample, had been submitted to the turbidimetric test, after each cycle. Amongst the units challenged with B. subtilis, viable load of 10³cfu was verified, surface damages were noticed on the specimen samples after tenth reprocessing cycles, but no toxicity was observed. In the other challenge, a gradual increase in recovered percentage of bacterial endotoxin was verified. Taking into consideration the obtained results, we do not recommend reprocessing of single use medical devices.

  9. Stability of ceftazidime (with arginine) stored in plastic syringes at three temperatures.

    Science.gov (United States)

    Nahata, M C; Morosco, R S; Fox, J L

    1992-12-01

    The stability of ceftazidime (with arginine) stored in plastic syringes at three temperatures was studied. Ceftazidime (with arginine) was reconstituted with sterile water for injection to a concentration of 100 mg/mL and transferred to plastic syringes. Syringes were stored at 22 degrees C for 24 hours; at 4 degrees C for 7 or 10 days, then at 22 degrees C for 24 hours; or at -20 degrees C for 91 days, then at 22 degrees C for 24 hours or at 4 degrees C for seven days followed by 22 degrees C for 24 hours. Ceftazidime concentration was measured at various times by using a stability-indicating high-performance liquid chromatographic method. At each sampling time, each syringe was visually inspected and the pH of each solution was measured. Mean ceftazidime concentration remained > 90% of initial concentration at all storage conditions. Although during storage the color of the solutions changed from light straw to dark yellow and the pH decreased, no precipitate was visually detected and no peaks for degradation products appeared on the chromatograms. Ceftazidime 100 mg/mL (with arginine) in sterile water for injection was stable when stored in plastic syringes for up to 24 hours at 22 degrees C, for 10 days at 4 degrees C followed by up to 24 hours at 22 degrees C, and for 91 days at -20 degrees C followed by up to 24 hours at 22 degrees C or by 7 days at 4 degrees C and up to 24 hours at 22 degrees C.

  10. Indications and the requirements for single-use medical gloves

    Science.gov (United States)

    Kramer, Axel; Assadian, Ojan

    2016-01-01

    Aim: While the requirements for single-use gloves for staff protection are clearly defined, the conventional medical differentiation between “sterile surgical gloves” used during surgical procedures and “single-use medical gloves” used in non-sterile medical areas does not adequately define the different requirements in these two areas of use. Sterilization of single-use medical gloves is not performed if sterility is not required; thus, another terminology must be found to identify the safety quality of non-sterile single-use medical gloves. Therefore, the labeling of such gloves should reflect this situation, by introducing the term “pathogen-free” single-use glove. The hygienic safety of such a glove would be attainable by ensuring aseptic manufacturing conditions during manufacturing and control of pathogen load of batch controls after fabrication. Proposed recommendation: Because single-use gloves employed in non-sterile areas come into contact not only with intact skin but also with mucous membranes, no potential pathogens should be detectable in 100 mL of rinse sample. In order to declare such gloves as pathogen-free we suggest absence of the indicator species S. aureus and E. coli. In addition, the total CFU count should be evaluated, since a high load indicates lack of optimal hygiene during the manufacturing process. Based on the requirements for potable water and findings obtained from investigations of the bacterial load of such gloves after manufacturing, the here suggested limit for the total bacterial count of glove seems realistic. PMID:26816673

  11. Syringe siliconization process investigation and optimization.

    Science.gov (United States)

    Chan, Edwin; Hubbard, Aaron; Sane, Samir; Maa, Yuh-Fun

    2012-01-01

    The interior barrel of the prefilled syringe is often lubricated/siliconized by the syringe supplier or at the syringe filling site. Syringe siliconization is a complex process demanding automation with a high degree of precision; this information is often deemed "know-how" and is rarely published. The purpose of this study is to give a detailed account of developing and optimizing a bench-top siliconization unit with nozzle diving capabilities. This unit comprises a liquid dispense pump unit and a nozzle integrated with a Robo-cylinder linear actuator. The amount of coated silicone was determined by weighing the syringe before and after siliconization, and silicone distribution was visually inspected by glass powder coating or characterized by glide force testing. Nozzle spray range, nozzle retraction speed, silicone-coated amount, and air-to-nozzle pressure were found to be the key parameters affecting silicone distribution uniformity. Distribution uniformity is particularly sensitive to low-target silicone amount where the lack of silicone coating on the barrel near the needle side often caused the syringes to fail the glide force test or stall when using an autoinjector. In this bench-top unit we identified optimum coating conditions for a low silicone dose, which were also applicable to a pilot-scale siliconization system. The pilot unit outperformed the bench-top unit in a tighter control (standard deviation) in coated silicone amount due to the elimination of tubing flex. Tubing flex caused random nozzle mis-sprays and was prominent in the bench-top unit, while the inherent design of the pilot system substantially limited tubing flux. In summary, this bench-top coating unit demonstrated successful siliconization of the 1 mL long syringe with ∼0.2 mg of silicone oil using a spraying cycle also applicable to larger-scale siliconization. Syringe siliconization can be considered a well-established manufacturing process and has been implemented by numerous

  12. Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures

    International Nuclear Information System (INIS)

    Haseler, Luke J.; Sibbitt, Randy R.; Sibbitt, Wilmer L.; Michael, Adrian A.; Gasparovic, Charles M.; Bankhurst, Arthur D.

    2011-01-01

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm 2 ), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.

  13. Radiation safety shield for a syringe

    International Nuclear Information System (INIS)

    Tipton, H.W.

    1976-01-01

    Safety apparatus for use in administering radioactive serums by a syringe, without endangering the health and safety of the medical operators is described. The apparatus consists of a sheath and a shield which can be retracted into the sheath to assay the radioactive serum in an assay well. The shield can be moved from the retracted position into an extended position when the serum is to be injected into the patient. To protect the operator, the shield can be constructed of tantalum or any like high density substance to attenuate the radiation, emanating from the radioactive serums contained in the syringe, from passing to the atmosphere. A lead glass window is provided so that the operator can determine the exact quantity of the radioactive serum which is contained in the syringe

  14. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Lu, Xujin; Lloyd, David K; Klohr, Steven E

    2016-01-01

    A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing

  15. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  16. Structure of the syringeal muscles in jungle crow (Corvus macrorhynchos).

    Science.gov (United States)

    Tsukahara, Naoki; Yang, Qian; Sugita, Shoei

    2008-09-01

    Birds' vocalizations are produced by the syrinx, which is located between the trachea and the two primary bronchi. Oscine birds have multiple pairs of syringeal muscles in the syrinx. To determine the detailed structure of the syringeal muscle in jungle crows, an oscine bird, a histological study and gross examination of the syrinx were performed. In the histological study, sections of the syrinxes from four jungle crows were stained with Azan and observed. Each syringeal muscle was classified by the limit of the fascia from neighbor fascicules. From the gross examination a 3-D image of the structure of the syringeal muscles was generated. The combined histological and anatomical results show that there are seven pairs of syringeal muscles in jungle crows. Muscle fusions were observed in some of the syringeal muscles. It is likely that each syringeal muscle has a specific role. Jungle crows may be able to generate various calls because they have several pairs of syringeal muscles.

  17. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  18. Syringe irrigation: blending endodontics and fluid dynamics

    NARCIS (Netherlands)

    Boutsioukis, C.; van der Sluis, L.W.M.; Basrani, B.

    2015-01-01

    Syringe irrigation remains a widely used irrigant delivery method during root canal treatment. An interdisciplinary approach involving well-established methods from the field of fluid dynamics can provide new insights into the mechanisms involved in cleaning and disinfection of the root canal system

  19. Open-Source Syringe Pump Library

    Science.gov (United States)

    Wijnen, Bas; Hunt, Emily J.; Anzalone, Gerald C.; Pearce, Joshua M.

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications. PMID:25229451

  20. Aspects of syringeal mechanics in avian phonation

    NARCIS (Netherlands)

    Larsen, O.N.; Goller, F.; Leeuwen, van J.L.

    2006-01-01

    The vocal organ of birds, the syrinx, is formed by modified cartilages of the trachea and bronchi. Recently, the use of thin, flexible endoscopes has made direct observation of the syrinx possible in situ. The effects of direct muscle stimulation on the syringeal aperture identified adductor and

  1. Interval Female Sterilization.

    Science.gov (United States)

    Stuart, Gretchen S; Ramesh, Shanthi S

    2018-01-01

    Female sterilization is relied on by nearly one in three women aged 35-44 years in the United States. Sterilization procedures are among the most common procedures that obstetrician-gynecologists perform. The most frequent sterilization procedures include postpartum tubal ligation, laparoscopic tubal disruption or salpingectomy, and hysteroscopic tubal occlusion. The informed consent process for sterilization is crucial and requires shared decision-making between the patient and the health care provider. Counseling should include the specific risks and benefits of the specific surgical approaches. Additionally, women should be counseled on the alternatives to sterilization, including intrauterine contraceptives and subdermal contraceptive implants. Complications, including unplanned pregnancy after successful female sterilization, are rare. The objectives of this Clinical Expert Series are to describe the epidemiology of female sterilization, access to postpartum sterilization, advances in interval sterilization techniques, and clinical considerations in caring for women requesting sterilization.

  2. Insulin Syringe: A Gimmick in Pediatric Dentistry.

    Science.gov (United States)

    Kour, Gurpreet; Masih, Updesh; Singh, Chanchal; Srivastava, Manvi; Yadav, Priti; Kushwah, Jagriti

    2017-01-01

    The management of pain and anxiety in dentistry encompasses a number of procedural issues, including the delivery of anesthetic solution. One of the most important ways to manage the behavior of children is pain control. Trypanophobia is very common among dental patients and the most important goal of guidelines on behavior guidance for pediatric dental patient is to ease fear and anxiety in dental procedures in children. For the stated reasons, the purpose of the present study was to record child's pain sensation both objectively and subjectively while receiving dental local anesthesia using conventional syringes and diabetic needles. Twenty children of age group 6 to 12 years undergoing routine dental procedures participated in the study. Every child acted as one's own control, while receiving treatment on the opposite side of the same arch. Each patient was randomly assigned to receive the injection either with conventional syringe or diabetic needle for the first visit, while the injection with the other needle was administered during the second visit. Rating scales were used for objective and subjective evaluations. Statistical analysis of the measurements were made using Wilcoxon signed U test and Mann-Whitney U test which showed the mean sound, eye, motor (SEM) score difference using insulin syringe. The outcome was statistically significant when compared using the mean ranks between male and female patients with that of control group. It can be concluded that diabetic syringes exhibit clinical advantage and its use in pediatric dentistry for local anesthetics (LA) infiltration can prove beneficial. How to cite this article: Kour G, Masih U, Singh C, Srivastava M, Yadav P, Kushwah J. Insulin Syringe: A Gimmick in Pediatric Dentistry. Int J Clin Pediatr Dent 2017;10(4):319-323.

  3. Health Care: Reprocessed Medical Single-Use Devices in DoD

    National Research Council Canada - National Science Library

    2002-01-01

    ... for decontamination and resterilization. The emergence of new materials and sterilization methods, and the increasing costs of health care, resulted in the development of medical single-use devices and the practice of reprocessing the devices...

  4. Social-structural contexts of needle and syringe sharing behaviours of HIV-positive injecting drug users in Manipur, India: a mixed methods investigation

    Directory of Open Access Journals (Sweden)

    Shunmugam Murali

    2011-05-01

    Full Text Available Abstract Background Few investigations have assessed risk behaviours and social-structural contexts of risk among injecting drug users (IDUs in Northeast India, where injecting drug use is the major route of HIV transmission. Investigations of risk environments are needed to inform development of effective risk reduction interventions. Methods This mixed methods study of HIV-positive IDUs in Manipur included a structured survey (n = 75, two focus groups (n = 17, seven in-depth interviews, and two key informant interviews. Results One-third of survey participants reported having shared a needle/syringe in the past 30 days; among these, all the men and about one-third of the women did so with persons of unknown HIV serostatus. A variety of social-structural contextual factors influenced individual risk behaviours: barriers to carrying sterile needles/syringes due to fear of harassment by police and "anti-drug" organizations; lack of sterile needles/syringes in drug dealers' locales; limited access to pharmacy-sold needles/syringes; inadequate coverage by needle and syringe programmes (NSPs; non-availability of sterile needles/syringes in prisons; and withdrawal symptoms superseding concern for health. Some HIV-positive IDUs who shared needles/syringes reported adopting risk reduction strategies: being the 'last receiver' of needles/syringes and not a 'giver;' sharing only with other IDUs they knew to be HIV-positive; and, when a 'giver,' asking other IDUs to wash used needles/syringes with bleach before using. Conclusions Effective HIV prevention and care programmes for IDUs in Northeast India may hinge on several enabling contexts: supportive government policy on harm reduction programmes, including in prisons; an end to harassment by the police, army, and anti-drug groups, with education of these entities regarding harm reduction, creation of partnerships with the public health sector, and accountability to government policies that protect IDUs

  5. Study on the radiation effect of plastic syringe materials

    International Nuclear Information System (INIS)

    Byun, H.C.; Yun, B.M.; Kim, K.Y.; Kong, Y.K.; Park, H.Y.

    1983-01-01

    From the viewpoint of gammasterilization, the defects of domestic polypropylene as the syringe material are to get worse the mechanical properties and discoloration by irradiation. Therefore, the domestic polystyrene (GPPS 150) were inspected to use as substitute for the polypropylene. The gel point of the polystyrene was about 100Mrad and none momentous change of the mechanical properties were appeared until the dose reached to the point. Above the point, as the crosslinking reaction proceed both strength of tensile and impact were increased with discoloration. No significant problem was also found in the water extract test and chemical resistance test. In addition to the pure polystyrene, the copolymer of butadiene (HIPS 425) and the blend material of polypropylene were also inspected for the purpose and almost same results were obtained in the radiation irradiation. From the above result, it is considered that polystyrene and the copolymer and the blend mentioned above are available for the medical plastics which would be sterilized by gamma-radiation. (Author)

  6. Development of Syringe/Bottle Hybrids for Sampling Slurries

    International Nuclear Information System (INIS)

    Coleman, C.J.

    1998-01-01

    A convenient and effective sample bottle system based on simple modifications of disposable plastic syringes and bottles has been devised and tested for slurry samples. Syringe/ bottle hybrids (hereafter referred to as syringe bottles) have the convenience of regular flat-bottom bottles with screw cap closures. In addition, the syringe imparts a sliding and adjustable bottom to the bottle that forces the entire contents from the bottle. The system was designed especially to collect samples for high temperature work-ups of DWPF slurry samples. The syringe bottles together with fixed-bottom sample vial inserts would provide the DWPF with convenient and reliable methods for dealing with slurry samples

  7. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  8. Autologous fat grafting: use of closed syringe microcannula system for enhanced autologous structural grafting

    Directory of Open Access Journals (Sweden)

    Alexander RW

    2013-04-01

    available as safe, sterile, disposable, compact systems for acquiring high-quality AFG. Presented is a detailed, step-by-step, proven protocol for performing quality autologous structural adipose transplantation. Keywords: autologous fat grafting, closed syringe lipoaspiration, adipose-derived adult stem-stromal cell, bioscaffolds, lipoaspiration/liposuction, stromal vascular fraction (SVF

  9. Sterile neutrinos in cosmology

    Science.gov (United States)

    Abazajian, Kevork N.

    2017-11-01

    Sterile neutrinos are natural extensions to the standard model of particle physics in neutrino mass generation mechanisms. If they are relatively light, less than approximately 10 keV, they can alter cosmology significantly, from the early Universe to the matter and radiation energy density today. Here, we review the cosmological role such light sterile neutrinos can play from the early Universe, including production of keV-scale sterile neutrinos as dark matter candidates, and dynamics of light eV-scale sterile neutrinos during the weakly-coupled active neutrino era. We review proposed signatures of light sterile neutrinos in cosmic microwave background and large scale structure data. We also discuss keV-scale sterile neutrino dark matter decay signatures in X-ray observations, including recent candidate ∼3.5 keV X-ray line detections consistent with the decay of a ∼7 keV sterile neutrino dark matter particle.

  10. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  11. Electron sterilization validation techniques using the controlled depth of sterilization process

    Science.gov (United States)

    Cleghorn, Denise A.; Nablo, Sam V.

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. most of these products are filled under aseptic conditions so that for qualification as a sterile product, techniques are often required only for treatment of the container surfaces and package interior. Gas sterilization (ETO) is often used for this purpose but is beset with difficulties known to the reader, especially for critical "contact" products such as in the ophthalmic field. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and x-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating x-ray dose ratios are possible for the application of the technique. Some of these data illustrating package: parenteral ratios of 10 5:1 have been reported (Rangwalla et al, 1985; Aaronson and Nablo, 1988). Standard techniques have been developed for the validation of the process and are reported here. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed.

  12. A study of gross morphological and histological syringeal features of ...

    African Journals Online (AJOL)

    A study of gross morphological and histological syringeal features of true francolins (Galliformes: Francolinus, Scleroptila, Peliperdix and Dendroperdix spp.) and spurfowls ( Pternistis spp.) in a phylogenetic context.

  13. A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting

    Directory of Open Access Journals (Sweden)

    B C Ashok

    2015-01-01

    Full Text Available Background: Successful restoration of structure and function using autologous free fat grafts has remained elusive. Review of literature shows that various harvesting and preparation techniques have been suggested. The goal of these techniques is to obtain greater adipocyte cell survival and consequently more reliable clinical results. Materials and Methods: In our technique, a piece of mesh is kept at one end of the lipoaspiration syringe, which is then connected to the Suction pump. As one syringe fills, it is replaced by another one until the required amount of fat is obtained. Results: By using a polypropylene mesh in our technique, we can separate the transfusate from the harvested fat graft during harvesting itself. The fat graft thus obtained is dense and concentrated, with fewer impurities. Conclusion: Hence, we recommend our technique as a reliable method for extracting sterile emulsified fat in an economical way.

  14. Single-use device reuse risks.

    Science.gov (United States)

    Lee, Robert C; Berzins, Sandy; Alfieri, Nancy

    2007-01-01

    Efforts to reduce both costs and medical waste have led many health systems to start reusing single-use medical devices (SUDs) after cleaning and sterilizing (i.e. reprocessing). There is a currently a wide range of SUD types being reused in many health systems. The objective of this paper is to provide a brief summary of risk issues associated with critical SUDs, based on a rapid review of the available literature. The specific focus is on risk issues, but includes discussion of economic and legal/ethical issues as well. The evidence in the literature regarding the safety of reuse of SUDs indicates that for certain devices (e.g. heart catheters) reuse can be safe (in terms of patient infection) and cost-effective as long as stringent reprocessing protocols are followed. However, potential risks associated with reusing SUDs are not just limited to infection of patients. There are staff and environmental risks, plus important legal, ethical, and financial issues to consider in a reuse policy. There are currently no Canadian guidelines on reuse or reprocessing SUDs, although a national Scientific Advisory Panel on Reprocessing of Medical Devices has made recommendations. Additionally, reuse of SUDs is interwoven with the issue of infection control and reprocessing procedures in general and as applied to multiple-use devices. With limited healthcare resources, there will always be a trade-off between the human resources and costs required to clean and sterilize reused devices with costs associated with purchasing and disposing of non-reused SUDs. Evaluation of complete operational pathways, especially for more expensive and commonly used SUDs, will be useful to properly determine the balance of benefits, risks, and costs under a reuse policy.

  15. Container Closure Integrity Testing of Prefilled Syringes.

    Science.gov (United States)

    Peláez, Sarah S; Mahler, Hanns-Christian; Matter, Anja; Koulov, Atanas; Singh, Satish K; Germershaus, Oliver; Mathaes, Roman

    2018-04-04

    Prefilled syringes (PFSs) are increasingly preferred over vials as container closure systems (CCSs) for injectable drug products when facilitated or self-administration is required. However, PFSs are more complex compared to CCSs consisting of vial, rubber stopper and crimp cap. Container closure integrity (CCI) assurance and verification has been a specific challenge for PFSs as they feature several sealing areas. A comprehensive understanding of the CCS is necessary for an appropriate CCI assessment as well as for packaging development and qualification. A comprehensive CCI assessment of six different PFSs from three different manufacturers (including one polymeric PFS) was conducted using helium leak testing. PFS components were manipulated to systematically assess the contribution of the different sealing areas to CCI, namely rigid needle shield (RNS)/needle, RNS/tip cone and the individual ribs of a syringe plunger. The polymeric PFS required an equilibrium measurement for accurate CCIT. The different sealing areas and a single plunger rib were shown to provide adequate CCI. Acceptable tip cap movement until the point of CCI failure was estimated. The assessment of acceptable tip cap movement demonstrated the importance of considering the RNS/tip cone seal design to ensure CCI of the PFS upon post assembly possesses and shipment. Copyright © 2018. Published by Elsevier Inc.

  16. [Regret of female sterilization].

    Science.gov (United States)

    Öhman, Malin Charlotta; Andersen, Lars Franch

    2015-11-16

    Regret of sterilization is inversely correlated to age at the time of sterilization. The minimum age for legal sterilization in Denmark has recently been lowered to 18 years. In Denmark surgical refertilization has almost completely been replaced by in vitro fertilization (IVF). In recent literature pregnancy results after surgical refertilization are easily comparable to IVF. Refertilization may in some cases be advantageous to IVF treatment. Women requesting reversal of sterilization should be offered individualized evaluation and differentiated treatment. It is recommended that surgical refertilization is performed at very few centres.

  17. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  18. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    Science.gov (United States)

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical

  19. Needle and syringe sharing among Iranian drug injectors

    Directory of Open Access Journals (Sweden)

    Roshanpajouh Mohsen

    2009-07-01

    Full Text Available Abstract Objective The role of needle and syringe sharing behavior of injection drug users (IDUs in spreading of blood-borne infections – specially HIV/AIDS – is well known. However, very little is known in this regard from Iran. The aim of our study was to determine the prevalence and associates of needle and syringe sharing among Iranian IDUs. Methods In a secondary analysis of a sample of drug dependents who were sampled from medical centers, prisons and streets of the capitals of 29 provinces in the Iran in 2007, 2091 male IDUs entered. Socio-demographic data, drug use data and high risk behaviors entered to a logistic regression to determine independent predictors of lifetime needle and syringe sharing. Results 749(35.8% reported lifetime experience of needle and syringe sharing. The likelihood of lifetime needle and syringe sharing was increased by female gender, being jobless, having illegal income, drug use by family members, pleasure/enjoyment as causes of first injection, first injection in roofless and roofed public places, usual injection at groin, usual injection at scrotum, lifetime experience of nonfatal overdose, and history of arrest in past year and was decreased by being alone at most injections. Conclusion However this data has been extracted from cross-sectional design and we can not conclude causation, some of the introduced variables with association with needle and syringe sharing may be used in HIV prevention programs which target reducing syringe sharing among IDUs.

  20. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  1. Storage stability of bevacizumab in polycarbonate and polypropylene syringes

    Science.gov (United States)

    Khalili, H; Sharma, G; Froome, A; Khaw, P T; Brocchini, S

    2015-01-01

    Purpose To compare and examine the storage stability of compounded bevacizumab in polycarbonate (PC) and polypropylene (PP) syringes over a 6-month period. PC syringes have been used in a recent clinical study and bevacizumab stability has not been reported for this type of syringe. Methods Repackaged bevacizumab was obtained from Moorfields Pharmaceuticals in PC and PP syringes. Bevacizumab from the stored syringes was analysed at monthly time points for a 6-month period and compared with bevacizumab from a freshly opened vial at each time point. SDS-PAGE electrophoresis and size-exclusion chromatography (SEC) was used to observe aggregation and degradation. Dynamic light scattering (DLS) provided information about the hydrodynamic size and particle size distribution of bevacizumab in solution. VEGF binding and the active concentration of bevacizumab was determined by surface plasmon resonance (SPR) using Biacore. Results SDS-PAGE and SEC analysis did not show any changes in the presence of higher molecular weight species (HMWS) or degradation products in PC and PP syringes from T0 to T6 compared with bevacizumab sampled from a freshly opened vial. The hydrodynamic diameter of bevacizumab in the PC syringe after 6 months of storage was not significantly different to bevacizumab taken from a freshly opened vial. Using SPR, the VEGF binding activity of bevacizumab in the PC syringe was comparable to bevacizumab taken from a freshly opened vial. Conclusion No significant difference over a 6-month period was observed in the quality of bevacizumab repackaged into prefilled polycarbonate and polypropylene syringes when compared with bevacizumab that is supplied from the vial. PMID:25853399

  2. Syringe Administration of Epinephrine by Emergency Medical Technicians for Anaphylaxis.

    Science.gov (United States)

    Latimer, Andrew J; Husain, Sofia; Nolan, Jonathan; Doreswamy, Vinod; Rea, Thomas D; Sayre, Michael R; Eisenberg, Mickey S

    2018-01-15

    In recent years, the costs of epinephrine autoinjectors (EAIs) in the United States have risen substantially. King County Emergency Medical Services implemented the "Check and Inject" program to replace EAIs by teaching emergency medical technicians (EMTs) to manually aspirate epinephrine from a single-use 1 mg/mL epinephrine vial using a needle and syringe followed by prehospital intramuscular administration of the correct adult or pediatric dose of epinephrine for anaphylaxis or serious allergic reaction. Treatment was guided by an EMT protocol that required a trigger and symptoms. We sought to determine if the "Check and Inject" program was safely implemented by EMTs treating presumed prehospital anaphylaxis or serious allergic reaction. We conducted a prospective investigation of all cases treated as part of the "Check and Inject" program from July 2014 through December 2016 in suburban King County, Washington, and January 2016 through December 2016 within the city of Seattle. All cases were prospectively collected using a custom quality improvement data form completed by the first responding EMTs. Two physicians completed a structured review of each EMS medical record to determine if the EMTs followed the Check and Inject protocol and determine if epinephrine was clinically-indicated based on physician review. Of the 411 cases eligible for analysis, EMTs followed the protocol appropriately in 367 (89.3%) cases. In the remaining 44 (10.7%) cases, the EMS incident report form failed to document either a clear inciting allergic trigger or an appropriate symptom from the protocol list. Physician review determined that epinephrine was clinically indicated in 36 of the 44 cases. Among the remaining 8 cases (1.9%) that did not meet protocol criteria and were not clinically-indicated based on physician review, none had a documented adverse reaction to the epinephrine. We observed that EMTs successfully implemented the manual "Check and Inject" program for severe

  3. Sterilization by Laparoscopy

    Science.gov (United States)

    ... If pregnancy does occur, the risk of an ectopic pregnancy is higher than in women who did not ... pregnant. Also, the risk of problems, such as ectopic pregnancy, is increased. What are some alternatives to sterilization? ...

  4. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  5. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  6. Contraception Update: Sterilization.

    Science.gov (United States)

    Antell, Karen; Deshmukh, Prium; Brown, Elizabeth J

    2017-11-01

    Female sterilization procedures include postpartum partial salpingectomy via cesarean or minilaparotomy incision, interval laparoscopic procedures, or hysteroscopic placement of microinserts. Rates of failure and serious complications are low and comparable among the various methods. A hysteroscopic procedure requires a 3-month confirmatory hysterosalpingogram before it is considered effective for contraception. Hysteroscopic sterilization has been shown to be associated with a higher reoperation rate than laparoscopic procedures. For male sterilization, vasectomy is a noninvasive and highly effective method. Vasectomy is an outpatient procedure performed under local anesthesia. The procedure requires confirmation of azoospermia with a semen analysis 8 to 16 weeks after the procedure. Patients who are considering sterilization should be counseled about all the available options and the permanent nature of such procedures. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  7. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  8. Introduction to sterile neutrinos

    Science.gov (United States)

    Volkas, R. R.

    2002-07-01

    Model-building issues raised by the prospect of light sterile neutrinos are discussed in a pedagogical way. I first review the naive proposal that sterile neutrinos be identified with “right handed neutrinos”. A critical discussion of the simple expedient of adding three gauge singlet fermions to the usual minimal standard model matter content is followed by an examination of right handed neutrinos in extended theories. I introduce the terminology of “fully sterile” and “weakly sterile” to classify varieties usually conflated under the sterile neutrino banner. After introducing the concepts of “technical naturalness” and plain “naturalness”, the unbearable lightness of being a sterile neutrino is confronted. This problem is used to motivate mirror neutrinos, whose connection with pairwise maximal mixing is emphasised. Some brief remarks about phenomenology are made throughout. The impossibility of identifying the sole sterile neutrino of the currently favoured 2 + 2 and 3 + 1 phenomenological constructs as a lone gauge singlet fermion added to the minimal standard model is explained. Finally, I remark on the beauty and subtlety of light sterile neutrino cosmology.

  9. Prefilled syringes for intravitreal injection reduce preparation time

    DEFF Research Database (Denmark)

    Subhi, Yousif; Kjer, Birgit; Munch, Inger Christine

    2016-01-01

    INTRODUCTION: The demand for intravitreal therapy has increased dramatically with the introduction of vascular endo-thelial growth factor inhibitors. Improved utilisation of existing resources is crucial to meeting the increased future demand. We investigated time spent preparing intravitreal...... injection treatment using either prefilled syringes or vials in routine clinical practice. METHODS: We video-recorded preparations of intravitreal injections (n = 172) for each preparation type (ranibizumab prefilled syringe (n = 56), ranibizumab vial (n = 56) and aflibercept vial (n = 60)) in a multi......-centre time and motion study. The preparation times for each step were extracted from videos and the three preparation types were compared. RESULTS: Prefilled syringes eliminated several steps in the preparation process. Total preparation time was 40.3-45.1 sec. using vials, and the use of prefilled syringes...

  10. Hypertensive Crisis During Norepinephrine Syringe Exchange: A Case Report.

    Science.gov (United States)

    Snijder, Roland A; Knape, Johannes T A; Egberts, Toine C G; Timmerman, Annemoon M D E

    2017-04-01

    A 67-year critically ill patient suffered from a hypertensive crisis (200 mm Hg) because of a norepinephrine overdose. The overdose occurred when the clinician exchanged an almost-empty syringe and the syringe pump repeatedly reported an error. We hypothesized that an object between the plunger and the syringe driver may have caused the exertion of too much force on the syringe. Testing this hypothesis in vitro showed significant peak dosing errors (up to +572%) but moderate overdose (0.07 mL, +225%) if a clamp was used on the intravenous infusion line and a large overdose (0.8 mL, +2700%) if no clamp was used. Clamping and awareness are advised.

  11. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  12. Better health care: Ghana uses radiation technology to sterilize medical items

    International Nuclear Information System (INIS)

    Dixit, Aabha

    2015-01-01

    Infections acquired from improperly sterilized equipment are recognized as a major impediment to safe health care delivery, with consequences that are often deadly for patients. Radiation technology plays a major role in many countries in making medical equipment safer. “The use of nuclear applications, such as exposing medical items to gamma radiation, helps Ghana protect its people from avoidable sicknesses that can occur if items like syringes are not properly sterilized,” said Abraham Adu-Gyamfi, Manager of the Radiation Technology Centre of the Ghana Atomic Energy Commission’s Biotechnology and Nuclear Agriculture Research Institute in Accra.

  13. Hysteroscopic Tubal Sterilization

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  14. Sterilization: A Review and Update.

    Science.gov (United States)

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Auricular Clyster, Otenchytes, and Pyoulcos: Precursors of the Ear Syringe.

    Science.gov (United States)

    Rousseau, Nathalie; Mudry, Albert

    2018-04-01

    In Western medicine, the long history of the ear syringe dates back at least to the end of the 1st millennium BCE; but the corresponding Ancient Greek word surinx designates another tool. Other Greek and Latin words and phrases, in particular auricular clyster, otenchytes, and pyoulcos, were known as names of the ear syringe until modern times. The aim of this article is to study the Greek and Latin words and phrases referred to as names of the ear syringe up until modern times before syringe became the standard word. Historical and philological review of ancient Greek and Latin medical literature dealing with the subject. Careful reading of ancient medical texts mentioning these tools shows a variety of shapes and uses: beside the piston-driven syringe, the system of a bladder attached to a catheter remained in use throughout Antiquity; the otenchytes, being a piston-driven syringe, obviously was not used to squirt the liquid when the remedy put inside was warmed by a flame; the piston-driven pyoulcos is most likely of greater size, and never linked with ear care in Antiquity. Latin auricular clyster and Greek otenchytes and pyoulcos, in the few ancient texts in which they occur, designate tools of a large variety of shapes and uses, significantly different from Heron's description of piston-driven pyoulcos.

  16. Voluntary sterilization in Britain.

    Science.gov (United States)

    Jackson, L N

    1968-01-01

    Only recently has the value and importance of sterilization as an effective method of birth control come to be widely recognized in Britian. Credit for this recognition is largely due to the initiative of Dr. C. P. Blacker, chairman of the Simon Population Trust. The Trust's sterilization project was conceived by him and, heralded by an article in The Lancet on 30 April 1966, was launched at a press conference in London in May of that year. Since then the Project has gone from strength to strength. It first function was to make known how voluntary sterilization can help to solve or prevent family problems and to facilitate its practice in Britian. The project has also been concerned to correct the erroneous belief, still held by a dwindling number of medical and law persons, that sterilization is against the law. A prerequisite was to enlist cooperative surgeons all over the country, whose names are now being sent on request to family doctors wishing to refer men for sterilization. The project is concerned mainly with male, rather than female, sterilization. The reason for this is that, when the relative simplicity of vasectomy as compared with tubal ligation is explained to them most couples choose vasectomy. Information about sterilization is supplied not only to applicants but also to university and hospital authorities, surgeons, health and welfare workers, family planning clinics. Forms of consent are provided for the couple concerned, and a follow-up inquiry is being conducted on a substantial scale among men who have been sterilized through the agency of the Project. Though this inquiry is far from complete, replies so far received indicate almost universal satisfaction with the results of the operation. Indeed, with the fear of unwanted pregnancies removed, many couples report that marital harmony is increased. It is known that at least 2000 men have already been sterilized through the mediation of this Project and, as family doctors become increasingly

  17. Reprocessamento e reutilização de material odonto-médico-hospitalar de uso único: busca de evidências pela revisão sistemática de literatura científica Reprocesamiento y reutilización de material odontológico- médico y hospitalario de uso único. Búsqueda de evidencias por la revisión sistemática de literatura científica Re-sterilization and re-utilization of single use of dental and medical devices: a systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Carla Patrícia Amaral Carvalho Denser

    2006-09-01

    reprocesamiento y reutilización basados en conocimiento científico con niveles de evidencia bien establecidos.OBJECTIVE: to search for scientific evidence to support the re-sterilization and re-utilization of dental and medical single use devices. METHODS: twenty basic research publications and one review article were used to conduct a systematic review of the literature. RESULTS: in spite of the majority of studies being classified as experimental, only 3 studies used randomization. There were mixed results regarding evidence to support the re-sterilization and re-utilization of single use devices, which might be in part due to non-standardized method re-sterilization and quality control. CONCLUSION: re-sterilization and re-utilization of single use devices cannot be applied to general practice. It is crucial to consider case by case based on validation of scientific protocol and evidence of quality control.

  18. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  19. Avaliação da intensidade de contaminação de pontas de seringa tríplice Evaluation of the bacterial contamination of air/water syringes tips

    Directory of Open Access Journals (Sweden)

    Eliza Maria Agueda RUSSO

    2000-09-01

    transported to the laboratory and, under aseptic condition, rolled and compressed on a Tryptic Soy Agar surface with 5% of defibrillated sheep blood. After a 96-hour incubation, the reading was carried out with the help of a lens. According to the manufacture’s information, the disposable tips were sterilized. In all of the tips used in patients, an uncountable amount of cfu (colony formation units was found, revealing great contamination. In the disposable tips disinfected after being used, there was small bacterial growth, but that was incompatible with cross-contamination prevention. Therefore, we conclude that disposable air/water syringes tips must have a single use.

  20. Heat sterilization of wood

    Science.gov (United States)

    Xiping Wang

    2010-01-01

    Two important questions should be considered in heat sterilizing solid wood materials: First, what temperature–time regime is required to kill a particular pest? Second, how much time is required to heat the center of any wood configuration to the kill temperature? The entomology research on the first question has facilitated the development of international standards...

  1. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  2. Sterilization of Native Americans

    Science.gov (United States)

    Dillingham, Brint

    1977-01-01

    The U.S. State Department's Agency for International Development (AID) is spending more than $143 million this year for population control measures in over 70 nations around the world and it is estimated that as much as $10 million was spent in one year for surgical sterilization procedures. (JC)

  3. Extractables analysis of single-use flexible plastic biocontainers.

    Science.gov (United States)

    Marghitoiu, Liliana; Liu, Jian; Lee, Hans; Perez, Lourdes; Fujimori, Kiyoshi; Ronk, Michael; Hammond, Matthew R; Nunn, Heather; Lower, Asher; Rogers, Gary; Nashed-Samuel, Yasser

    2015-01-01

    Studies of the extractable profiles of bioprocessing components have become an integral part of drug development efforts to minimize possible compromise in process performance, decrease in drug product quality, and potential safety risk to patients due to the possibility of small molecules leaching out from the components. In this study, an effective extraction solvent system was developed to evaluate the organic extractable profiles of single-use bioprocess equipment, which has been gaining increasing popularity in the biopharmaceutical industry because of the many advantages over the traditional stainless steel-based bioreactors and other fluid mixing and storage vessels. The chosen extraction conditions were intended to represent aggressive conditions relative to the application of single-use bags in biopharmaceutical manufacture, in which aqueous based systems are largely utilized. Those extraction conditions, along with a non-targeted analytical strategy, allowed for the generation and identification of an array of extractable compounds; a total of 53 organic compounds were identified from four types of commercially available single-use bags, the majority of which are degradation products of polymer additives. The success of this overall extractables analysis strategy was reflected partially by the effectiveness in the extraction and identification of a compound that was later found to be highly detrimental to mammalian cell growth. The usage of single-use bioreactors has been increasing in biopharmaceutical industry because of the appealing advantages that it promises regarding to the cleaning, sterilization, operational flexibility, and so on, during manufacturing of biologics. However, compared to its conventional counterparts based mainly on stainless steel, single-use bioreactors are more susceptible to potential problems associated with compound leaching into the bioprocessing fluid. As a result, extractable profiling of the single-use system has become

  4. Options for reducing HIV transmission related to the dead space in needles and syringes.

    Science.gov (United States)

    Zule, William A; Pande, Poonam G; Otiashvili, David; Bobashev, Georgiy V; Friedman, Samuel R; Gyarmathy, V Anna; Des Jarlais, Don C

    2018-01-15

    When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would remain in different combinations following injection and rinsing. Syringe barrel capacities ranged from 0.5 to 20 mL. Needles ranged in length from 8 to 38 mm. The average dead space was 3 μL in low dead space syringes with permanently attached needles, 13 μL in high dead space syringes with low dead space needles, 45 μL in low dead space syringes with high dead space needles, and 99 μL in high dead space syringes with high dead space needles. Among low dead space designs, calculated volumes of blood and HIV viral burden were lowest for low dead space syringes with permanently attached needles and highest for low dead space syringes with high dead space needles. The dead space in different low dead space needle and syringe combinations varied substantially. To reduce HIV transmission related to syringe sharing, needle and syringe programs need to combine this knowledge with the needs of their clients.

  5. 21 CFR 880.6850 - Sterilization wrap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  6. Construction and Operation of a Commercial Gamma-Ray Package-Sterilizing Plant

    International Nuclear Information System (INIS)

    Crawford, C.G.

    1963-01-01

    The purpose of the paper is to describe the Co 60 sterilizing plant now being operated commercially by Johnson's Ethical Plastics Limited, at Slough, England. This is a continuous process plant with a source of 72000 c and completely automatic operation. Based on experience gained by U.K.A.E.A. in their Package Irradiation Plant at Wantage, the present plant was designed specifically for sterilization of disposable plastic syringes and other medical products of similar bulk density. The plant has been in operation since November 1962. A description is given of the main features of its construction, including personnel safety devices, and method of loading the source rods. Operating experience is described including dosimetry, integration of the plant into a commercial undertaking as a production process, and bacteriological results. A short discussion on the economics of sterilizing by gamma radiation is given and an assessment of possible future applications of a plant of this type. (author) [fr

  7. Sterile neutrino anarchy

    Science.gov (United States)

    Heeck, Julian; Rodejohann, Werner

    2013-02-01

    Lepton mixing, which requires physics beyond the Standard Model, is surprisingly compatible with a minimal, symmetryless and unbiased approach, called anarchy. This contrasts with highly involved flavor symmetry models. On the other hand, hints for light sterile neutrinos have emerged from a variety of independent experiments and observations. If confirmed, their existence would represent a groundbreaking discovery, calling for a theoretical interpretation. We discuss anarchy in the two-neutrino eV-scale seesaw framework. The distributions of mixing angles and masses according to anarchy are in agreement with global fits for the active and sterile neutrino parameters. Our minimal and economical scenario predicts the absence of neutrinoless double beta decay and one vanishing neutrino mass, and can therefore be tested in future experiments.

  8. Abortion and sterilization.

    Science.gov (United States)

    Steele, S J

    1970-01-01

    This discusses activities current in England under the abortion law of April 1968. In England and Wales in 1969 there were 54,013 recorded abortions and 15 related deaths. Since then both the number of deaths and the number of abortions have been increasing. This abortion increase is partly attributed to the adverse publicity regarding the pill which has caused many women to give up oral contraceptives. Complications have included incomplete removal of the products of conception, sepsis, hemorrhage, and perforation of the uterus. There have been wide variation in interpretations of the law by different hospitals and staffs. Sterilization operations are being done in increasing number for both men and women. Carefully worded consent forms are now in use to insure patient understanding and consent. Psychological changes may follow sterilization, but are relatively uncommon. Physicians should do all possible to help women avoid unwanted pregnancies and thereby reduce the demand for termination.

  9. What is the use? An international look at reuse of single-use medical devices.

    Science.gov (United States)

    Popp, Walter; Rasslan, Ossama; Unahalekhaka, Akeau; Brenner, Pola; Fischnaller, Edith; Fathy, Maha; Goldman, Carol; Gillespie, Elizabeth

    2010-07-01

    Reuse of single-use devices is common in most countries worldwide. We provide an overview of the issue from an international perspective. In many developing and transitional countries reuse of cheap single-use devices (needles, syringes, surgical gloves) is common leading to large numbers of unsafe interventions, specifically injections and, as a consequence, infection with hepatitis B, C or HIV. There are various reasons for reuse: limited resources, insufficient knowledge of healthcare workers and the belief of patients that injection is more beneficial than oral medication. Reuse of cheap single-use devices should cease and both medical staff and the public should be informed about potential safety risks associated with injection. In developed countries, reuse of single-use items is less common but may include expensive technical products. Reuse is regulated in many countries (e.g. US, Canada, some European countries) demanding ethical and legal considerations, high standards of reprocessing and training of staff, risk assessment, management and validation of reprocessing. Well regulated reprocessing can decrease the number of single-use devices reprocessed. In developing as well as developed countries, a decision to reprocess single-use devices should only be made after a critical reflection of advantages and disadvantages. Copyright 2010 Elsevier GmbH. All rights reserved.

  10. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  11. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  12. The syringe suction drain - A unique improvisation in rural plastic ...

    African Journals Online (AJOL)

    Background: Closed suction drains are often needed in surgical practice. However, they are luxury in rural plastic surgery practice. This study highlights how syringes have become a reliable substitute. Materials and methods: This is a prospective study of the surgical outcome of patient who had various plastic surgical ...

  13. Impact of flushing with aseptic non-touch technique using pre-filled flush or manually prepared syringes on central venous catheter occlusion and bloodstream infections in pediatric hemato-oncology patients: A randomized controlled study.

    Science.gov (United States)

    Gerçeker, Gülçin Özalp; Sevgili, Seda Ardahan; Yardımcı, Figen

    2018-04-01

    To compare standardized flushing methods with aseptic non-touch technique; (1) Manually prepared syringes (2) Single-use prefilled flush syringes. Forty-eight PHO patients with Hickman or Port catheters were recruited to participate in a prospective, randomized study. Standardized flushing methods with aseptic non-touch technique (ANTT) using single-use pre-filled flush syringes (intervention group) or manually prepared syringes (control group) also included the pulsatile technique, use of 10-mL syringe size with 0.9% NaCl for flushing, flushing once a day, flushing training of the nurses. The effects of standardized flushing methods on occlusion and CLABSI evaluated. Of the patients in the intervention group, 8.7% (n: 2) had catheter occlusion, while this rate was 20.0% (n: 5) in the control group. Of the patients in the intervention group, 8.7% (n: 2) had CLABSI, while this rate was 36.0% (n: 9) in the control group. While there was no difference in occlusion, there was a difference between the groups in terms of CLABSI development. In the intervention group, CLABSI rate was 1.9/1000 per catheter-days, in the control group CLABSI rate was 10.1/1000 per catheter-days. In the intervention group, occlusion rate was 1.9/1000 per catheter-days, in the control group, occlusion rate was 5.6/1000 per catheter-days. Standardized flushing and single-use prefilled flush syringes are effective in reducing CLABSI rates in PHO patients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Electron beam sterilization for dishes

    International Nuclear Information System (INIS)

    Deren, Wang; Meizhen, Fang

    1995-01-01

    Modern biological science often needs various fine strike devices which are often made from non-toxic transparent plastic. The application of high temperature steam to the sterilization as a traditional methods often causes deformation and colour change. When chemicals are applied to the sterilization residure of chemical grain often causes toxicity. Only application of radiation to the sterilization can overcome this faults and carry out with sterility assurance at room temperature. In this research 1.3 MeV electron beam coming from Model JJ-2 accelerator was applied for sterilization to 96-well tissue culture plates. After clean packaging the plates were irradiated with 31.7 XGy and operational voltage 1.3 MeV and 100 μA on the PY device. Repeated tests demonstrate that the products are sterile. The output is 2 x 10 5 pieces for each year. (author)

  15. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  16. Sterilization in the United States

    Science.gov (United States)

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  17. Drug injecting and syringe use in the HIV risk environment of Russian penitentiary institutions: Qualitative study.

    Science.gov (United States)

    Sarang, Anya; Rhodes, Tim; Platt, Lucy; Kirzhanova, Valentina; Shelkovnikova, Olga; Volnov, Venyamin; Blagovo, Dmitri; Rylkov, Andrei

    2006-12-01

    Evidence highlights the prison as a high risk environment in relation to human immunodeficiency virus (HIV) and hepatitis C virus (HCV) transmission associated with injecting drug use. We undertook qualitative studies among 209 injecting drug users (IDUs) in three Russian cities: Moscow (n = 56), Volgograd (n = 83) and Barnaul in western Siberia (n = 70). Over three-quarters (77%) reported experience of police arrest related to their drug use, and 35% (55% of men) a history of imprisonment or detention. Findings emphasize the critical role that penitentiary institutions may play as a structural factor in the diffusion of HIV associated with drug injection in the Russian Federation. While drugs were perceived to be generally available in penitentiary institutions, sterile injection equipment was scarce and as a consequence routinely shared, including within large groups. Attempts to clean borrowed needles or syringes were inadequate, and risk reduction was severely constrained by a combination of lack of injecting equipment availability and punishment for its possession. Perceptions of relative safety were also found to be associated with assumptions of HIV negativity, resulting from a perception that all prisoners are HIV tested upon entry with those found HIV positive segregated. This study shows an urgent need for HIV prevention interventions in the Russian penitentiary system.

  18. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  19. A piezoelectric vibration-based syringe for reducing insertion force

    Science.gov (United States)

    Huang, Y. C.; Tsai, M. C.; Lin, C. H.

    2012-12-01

    Puncturing of the human skin with a needle is perhaps the most common invasive medical procedure. Clinical studies have revealed that tissue deformation and needle deflection are the primary problem for needle misplacement in percutaneous procedures. To avoid this, various techniques for reducing insertion forces during needle insertion have been considered. This paper presents a piezoelectric vibration-based syringe to reduce insertion force. AC power was applied to the piezoelectric elements to vibrate the needle with high frequency and thereby reduce the friction and cutting forces between the needle and tissue. Vibration mode shapes of the needle were observed by finite element analysis and verified by experimental results. Effects of reducing insertion force via the vibrating needle were also confirmed by inserting the needle into the porcine tissues. The proposed syringe, which minimizes the insertion force and overcomes limitations of needle materials, can be widely utilized in robot-assisted needle insertion systems.

  20. Benefits of concurrent syringe exchange and substance abuse treatment participation.

    Science.gov (United States)

    Kidorf, Michael; King, Van L; Peirce, Jessica; Pierce, Jessica; Kolodner, Ken; Brooner, Robert K

    2011-04-01

    Participation in syringe exchange programs (SEPs) is associated with many individual and public health benefits but may have little impact on reducing drug use without concurrent treatment engagement. This study evaluated rates of drug use, other risk behaviors, and illegal activities in newly registered SEP participants (N = 240) enrolled versus not enrolled in substance abuse treatment over a 4-month observation window and examined the effect of days in treatment on these outcomes. After controlling for baseline differences, SEP registrants enrolled in treatment (n = 113) reported less days of opioid and cocaine use, injection drug use, illegal activities, and incarceration than those not enrolled in treatment (n = 127). For those enrolled in treatment, days of treatment was strongly correlated with each of these outcomes. These findings provide good evidence for a dose-response effect of treatment in syringe exchangers and suggest that substance abuse treatment significantly expands the harm reduction benefits of SEP participation. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Procedure simplification: the role of single-use instruments in total knee arthroplasty.

    Science.gov (United States)

    Bhadra, Arup K; Kwiecien, Grzegorz J; Harwin, Steven F; Johnson, Aaron J; Mont, Michael A; Malkani, Arthur L

    2012-12-01

    In orthopaedic surgery, surgical site contamination leading to periprosthetic infections is a major concern with important morbidity, financial and emotional burden. Single-use instruments developed for total knee arthroplasties are intended to simplify the surgical procedure, decrease the number of surgical trays that require sterilization and reprocessing, decrease the incidence of possible contamination through breaks in surgical wraps, and improve operating room efficiency. As the demand for total knee arthroplasty continues to rise, a greater burden on the healthcare system may be created. The use of single-use instruments, cutting guides, and trials will play an increasing role in total knee arthroplasty through improved operating room efficiency.

  2. Radiation dose setting for sterilization of health care items in relation to product microbiological quality

    International Nuclear Information System (INIS)

    Norimah Yusof; Nagi Marsit; Asnah Hassan

    1997-01-01

    Radiation dose of 25 k gray is no longer a generally accepted dose for sterilization. ISO document no. 11137 stated that a manufacturer can decide the dose to sterilize his product depending on the product's microbiological quality (number and type of the contaminants) and the sterility assurance level (SAL) should attain in relation to its usage. Five health care products were selected for the microbiological studies including bio burden counts, identification of most commonly found microorganisms and the radioresistance (D sub 10 value) of the selected isolates. Radiation dose was then determined by two methods, namely Method for Dose Validation of ISO 11137, and calculation based on log survival or population cycle reduction. At a given SAL of 10 sup -6 the radiation sterilization dose obtained by both methods was influenced by microbiological quality of the product. Sterilization dose set by the ISO Method I (Cotton Ball 19.4 kGy, Syringe 20.4 kGy, Suture 15. 0 kGy, Surgical Glove 24.9 kGy and Amnion 17.8 kGy) was higher than the dose calculated according to the log cycle reduction concept in all the products (Cotton Ball 14. 0 kGy, Syringe 15.5 kGy, Suture 11. 6 kGy, Surgical Glove 18. 0 kGy and Amnion 12.6 kGy). The ISO method has limitation on bio products such as amnion and other high valued products which are produced in small number with low bio burden and microorganism spectrum different from those commonly found on medical items

  3. Stability of erythropoietin repackaging in polypropylene syringes for clinical use

    Directory of Open Access Journals (Sweden)

    Angela Marsili

    2017-02-01

    Full Text Available Introduction: Epoetin alfa (Eprex® is a subcutaneous, injectable formulation of short half-life recombinant human erythropoietin (rHuEPO. To current knowledge there are no published studies regarding the stability of rHuEPO once repackaging occurs (r-EPO for clinical trial purposes. Materials and methods: We assessed EPO concentration in Eprex® and r-EPO syringes at 0, 60, 90, and 120 days after repackaging in polypropylene syringes. R-EPO was administered to 56 patients taking part in a clinical trial in Friedreich Ataxia. Serum EPO levels were measured at baseline and 48 h after r-EPO administration. Results: No differences were found between r-EPO and Eprex® syringes, but both globally decreased in total EPO content during storage at 4 °C. Patients receiving r-EPO had similar levels in EPO content as expected from previous trials in Friedreich Ataxia and from pharmacokinetics studies in healthy volunteers. Discussion: We demonstrate that repackaging of EPO does not alter its concentration if compared to the original product (Eprex®. This is true both for repackaging procedures and for the stability in polypropylene tubes. The expiration date of r-EPO can be extended from 1 to 4 months after repackaging, in accordance with pharmacopeia rules.

  4. Adrenaline in cardiac arrest: Prefilled syringes are faster.

    Science.gov (United States)

    Helm, Claire; Gillett, Mark

    2015-08-01

    Standard ampoules and prefilled syringes of adrenaline are widely available in Australasian EDs for use in cardiac arrest. We hypothesise that prefilled syringes can be administered more rapidly and accurately when compared with the two available standard ampoules. This is a triple arm superiority study comparing the time to i.v. administration and accuracy of dosing of three currently available preparations of adrenaline. In their standard packaging, prefilled syringes were on average more than 12 s faster to administer than the 1 mL 1:1000 ampoules and more than 16 s faster than the 10 mL 1:10,000 ampoules (P adrenaline utilising a Minijet (CSL Limited, Parkville, Victoria, Australia) is faster than using adrenaline in glass ampoules presented in their plastic packaging. Removing the plastic packaging from the 1 mL (1 mg) ampoule might result in more rapid administration similar to the Minijet. Resuscitation personnel requiring rapid access to adrenaline should consider storing it as either Minijets or ampoules devoid of packaging. These results might be extrapolatable to other clinical scenarios, including pre-hospital and anaesthesia, where other drugs are required for rapid use. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  5. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later

  6. Sterilization of Extracted Human Teeth.

    Science.gov (United States)

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  7. Medical hospital materials processing: a literature review on sterilization effectiveness

    Directory of Open Access Journals (Sweden)

    Leonardo Mousinho Guerra

    2013-04-01

    Full Text Available Backgound and Objectives: Surgical instruments are widely reprocessed, mainly in developing countries, where the cost of using these materials is high. Scientifi c literature indicates the absence of validated cleaning and sterilization processes. The study aimed at evaluating, through a literature review, the evidence to support or not the practice of reprocessing and reuse of originally single-use, medical-hospital materials. Methods: A total of 27 articles in English and Portuguese were selected from journals indexed in the LILACS, Pubmed and Medline databases, as well as studies published in ScienceDirect website using the following key words: sterilization, single-use articles, hospital infection and surgical instruments. Articles that did not fi t the study subject were excluded. Results: There was a great variety of studied instruments and reprocessing methods. Most articles emphasize the sterilization ineffectiveness, identifying microorganisms at the end of the process. Conclusion: Based on the current knowledge, it is important to consider each case validating surgical materials reprocessing and reuse protocols based on scientific knowledge. Based on the analysis of the study articles, we concluded that this practice cannot be performed indiscriminately. KEYWORDS: Sterilization. Cross infection. Surgical Equipment. Public Health.

  8. Conditional sterility in plants

    Science.gov (United States)

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  9. The Sterile Insect Technique

    International Nuclear Information System (INIS)

    Kiragu, J.

    2006-01-01

    Insect pests have caused an increasing problem in agriculture and human health through crop losses and disease transmission to man and livestock. Intervention to ensure food security and human health has relied on Integrated Pest Management (IPM) strategies to keep the pests population below economic injury levels. IPM integrate a variety of methods, but there has been over-reliance on chemical control following the discovery of insecticidal properties of DDT. It is now realized that, maintaining pest populations at controlled levels is unsustainable and eradication options is now being considered. Although the Sterile Insect Technique(SIT) could be used for insect suppression, it is gaining favour in the elimination (eradication) of the target pest population through Areawide-based IPM (Author)

  10. Ethylene Oxide Gaseous Sterilization

    Science.gov (United States)

    Ernst, Robert R.; Shull, James J.

    1962-01-01

    The duration of the equilibration period between admission of water vapor and subsequent introduction of gaseous ethylene oxide to an evacuated sterilizer chamber was studied with respect to its effect on the inactivation of spores of Bacillus subtilis var. niger under simulated practical conditions. Introduction of a water-adsorbing cotton barrier between the spores and an incoming gas mixture of water vapor and ethylene oxide caused a marked increase in the observed thermochemical death time of the spore populations. This effect was negated by admission of water vapor one or more minutes prior to introduction of ethylene oxide gas. Increases in temperature and relative humidity of the system promoted passage of water vapor through the cotton barriers and diminished their effect. PMID:13890660

  11. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  12. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  13. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  14. Medical hospital materials processing: a literature review on sterilization effectiveness

    OpenAIRE

    Leonardo Mousinho Guerra; Oswaldo Lima Almendra Neto; Dayane Alves Costa; Gerardo Vasconcelos Mesquita

    2013-01-01

    Backgound and Objectives: Surgical instruments are widely reprocessed, mainly in developing countries, where the cost of using these materials is high. Scientifi c literature indicates the absence of validated cleaning and sterilization processes. The study aimed at evaluating, through a literature review, the evidence to support or not the practice of reprocessing and reuse of originally single-use, medical-hospital materials. Methods: A total of 27 articles in English and Portuguese were se...

  15. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  16. Characterization of Protein Aggregating Tungstates: Electrospray Mass Spectrometry Analysis of Extracts from Prefilled Syringes and from Tungsten Pins Used in the Manufacture of Syringes.

    Science.gov (United States)

    Ronk, Michael; Lee, Hans; Fujimori, Kiyoshi; Yeh, Ping; Nashed-Samuel, Yasser

    2016-01-01

    Glass prefilled syringes are increasingly becoming a container of choice for storing and administering therapeutic protein products to patients. Tungsten leaching from a PFS is known to induce protein particle formation, and the source was traced to the tungsten pins used in the manufacturing process of the syringe barrels. Study of the tungstates present in extracts from both tungsten pins used in the syringe manufacturing process and from single syringes from various suppliers was undertaken. Electrospray mass spectrometry was chosen as a technique with the sensitivity to characterize tungstates at levels (∼1 ppm of elemental tungsten) observed in single syringes. Extraction solvents were chosen to simulate the range (pH 4.0-7.0) typically used for therapeutic protein formulation. A commercial product formulation buffer was also used as an extraction solution to characterize tungstate species used for tungsten spiking studies of protein. All pin and syringe extracts from various manufacturers were similar in regards to containing stable Na/K containing lacunary polytungstate ([W11O39](7-)) species, which were the main species present in syringe extracts and are different than the metatungstate ([W12O39](6-)) species identified in commercially available sodium polytungstate and as the main species in pin extracts. These stable Na/K containing polytungstates species present in pin and syringe extracts are likely formed during the glass manufacturing process at >400 °C and may have the capability to subsequently form larger polytungstate complexes. Glass prefilled syringes are a type of container used for storing and administering biotechnology medicines to patients. The manufacturing process for the syringes may lead to very low levels of the metal tungsten being present in the syringes, and thus in the medicine stored in the syringes. The presence of tungsten in certain biotechnology medicines has been shown to cause changes to the medicine. Understanding

  17. [Embolic complications by ink clots removed from syringes during cerebral angiography].

    Science.gov (United States)

    Kohyama, Shinya; Ishihara, Shoichiro; Yamane, Fumitaka; Ishihara, Hideaki; Kanazawa, Ryuzaburo; Suzuki, Masanori; Neki, Hiroaki; Ohkawara, Mai

    2009-01-01

    We noted, during cerebral angiography, that the contrast medium was contaminated with numerous small black ink clots from gradation marks on syringes. In this report, we show that ink can be removed from syringes in solid form, and that they may result in embolic complications during cerebral angiography. To demonstrate that the ink from gradation marks on syringes can come off in a solid form and attach itself to the gloves during cerebral angiography, syringes were gripped many times (just as in an angiographic procedure) after immersion in contrast medium or 0.9% saline for 10 minutes. To see if difference of contrast medium and syringes could affect the removing of ink, five types of nonangiographic syringes and one type of angiographic syringe were rubbed with gauze after certain time periods after immersing them in four kinds of contrast medium or 0.9% saline. Ink attached itself to the gloves in a solid form by repeated gripping due to adherence of contrast medium. Ink was removed from all nonangiographic syringes by rubbing after immersion in any type of contrast medium for two hours. Gradation marks on angiographic syringes were stable with all types of contrast medium. Thus, ink for gradation marks on nonangiographic syringes, which is easily removed in a solid form due to contrast medium, can be the source of embolic complication during cerebral angiography.

  18. Survival of Hepatitis C Virus in Syringes: Implication for Transmission among Injection Drug Users

    Science.gov (United States)

    Paintsil, Elijah; He, Huijie; Peters, Christopher; Lindenbach, Brett D.; Heimer, Robert

    2010-01-01

    Background We hypothesized that the high prevalence of HCV among injection drug users (IDUs) might be due to prolonged virus survival in contaminated syringes. Methods We developed a microculture assay to examine the viability of HCV. Syringes were loaded with blood spiked with HCV reporter virus (Jc1/GLuc2A) to simulate two scenarios of residual volumes; low (2 μl) void volume for 1-ml insulin syringes, and high (32 μl) void volume for 1-ml tuberculin syringes. Syringes were stored at 4°C, 22°C, and 37°C for up to 63 days before testing for HCV infectivity using luciferase activity. Results The virus decay rate was biphasic (t½ α = 0.4h and t½β = 28h). Insulin syringes failed to yield viable HCV beyond day one at all storage temperatures except for 4o in which 5% of syringes yielded viable virus on day 7. Tuberculin syringes yielded viable virus from 96%, 71%, and 52% of syringes following storage at 4o, 22° and 37o for 7 days, respectively, and yielded viable virus up to day 63. Conclusions The high prevalence of HCV among IDUs may be partly due to the resilience of the virus and the syringe type. Our findings may be used to guide prevention strategies. PMID:20726768

  19. [Sterilization: necessity or genocide?].

    Science.gov (United States)

    Muraro, R M

    1991-01-01

    Recent warnings by the UN Fund for Population Activities about the rapid growth of the world population and the overwhelming role in it played by impoverished women in developing countries are of interest to all women in Latin America. According to the document, Third World Women require drastic improvements in their socioeconomic positions in order to achieve reductions in their family sizes and avoid an increase in the world population from 5 billion at present to 10 billion in 2025, which would be a disaster for the planet. The document states that much of the environmental damage that would occur would be attributable to the combination of poverty and rapid population increase. If the proportion of the world's women using contraceptives increases from the current 45% to 58% by the year 2000, the world population in 2025 will be 8.5 billion. The document recommends that the amount of money invested in family planning be greatly increased by 2000 in order to make possible increased use of family planning. It appears, however, that much of the funding for family planning is under the control of private organizations and is used to serve the interests of foreign countries. The 2 principal private family planning organizations in Brazil, for example, received 18.2 million US dollars between 1978--84, which were used largely to finance a campaign of mass sterilization. Brazil's rate of population growth, which was 2.1% in 1980-85 and 1.8% in 1990, is expected to drop to 1.6% in 1995. With the decline in the rate of growth, the population will be 170 million in 2000 instead of the 220 million projected using data from the 1970s. A much higher proportion of fertile-aged women in Brazil is sterilized than in the US or Europe . Closer examination of the premises behind family planning policies shows them to be questionable. The premise that population density affects the environment is questionable; Japan, West Germany, and Holland have some of the highest population

  20. Bilateral innervation of syringeal muscles by the hypoglossal nucleus in the jungle crow (Corvus macrorhynchos).

    Science.gov (United States)

    Tsukahara, Naoki; Kamata, Naoki; Nagasawa, Miyuki; Sugita, Shoei

    2009-08-01

    Bird vocalizations are produced by contractions of syringeal muscles, which are controlled by the hypoglossal nucleus. In oscines, syringeal muscles are controlled by the hypoglossal nucleus ipsilaterally, whereas syringeal innervation is bilateral in non-oscines. We have determined the course of hypoglossal nerves in the jungle crow Corvus macrorhynchos. Our results indicate a cross-over of the hypoglossal nerve from the left side to the right side on the trachea 7 mm rostral to the Musculus sternotrachealis. We also investigated the innervation of the syringeal muscles of jungle crows from the hypoglossal nucleus using the horseradish peroxidase (HRP) method. After HRP was injected into the syringeal muscles on each side, HRP-labeled cells were found bilaterally in the hypoglossal nerve. These results suggest that the syringeal muscles of jungle crows are innervated bilaterally from the hypoglossal nucleus, although these birds are categorized as oscines.

  1. Food irradiation and sterilization

    International Nuclear Information System (INIS)

    Josephson, E.S.

    1981-01-01

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25 to 70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning in achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70 to 80 0 C (bacon to 53 0 C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurrence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40 0 C to -20 0 C). Radappertized foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for 'wholesomeness' (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effects of radappertization on the 'wholesomeness' characteristics of these foods. (author)

  2. Food irradiation and sterilization

    Science.gov (United States)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  3. Embedded nanomicro syringe on chip for molecular therapy

    Directory of Open Access Journals (Sweden)

    Jalil MA

    2011-11-01

    Full Text Available Muhammad Arif Jalil1, Nathaporn Suwanpayak2,3, Kathawut Kulsirirat3, Saisudawan Suttirak3, Jalil Ali4, Preecha P Yupapin31Ibnu Sina Institute of Fundamental Science Studies, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, Malaysia; 2King Mongkut's Institute of Technology Ladkrabang, Chumphon Campus, Chumphon, Thailand; 3Nanoscale Science and Engineering Research Alliance, Advanced Research Center for Photonics, Faculty of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand; 4Institute of Advanced Photonics Science, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, MalaysiaBackground: A novel nanomicro syringe system was proposed for drug storage and delivery using a PANDA ring resonator and atomic buffer. A PANDA ring is a modified optical add/drop filter, named after the well known Chinese bear. In principle, the molecule/drug is trapped by the force generated by different combinations of gradient fields and scattering photons within the PANDA ring. A nanomicro needle system can be formed by optical vortices in the liquid core waveguide which can be embedded on a chip, and can be used for long-term treatment. By using intense optical vortices, the required genes/molecules can be trapped and transported dynamically to the intended destinations via the nanomicro syringe, which is available for drug delivery to target tissues, in particular tumors. The advantage of the proposed system is that by confining the treatment area, the effect can be decreased. The use of different optical vortices for therapeutic efficiency is also discussed.Keywords: nanomicro syringe, nanomicro needle, molecular therapy, therapeutic efficiency, cancer

  4. User preference for a portable syringe pump for iloprost infusion.

    Science.gov (United States)

    Laria, Antonella; Lurati, Alfredo Maria; Re, Katia Angela; Marrazza, Maria Grazia; Mazzocchi, Daniela; Farina, Alberto; Scarpellini, Magda

    2015-01-01

    Administration of intravenous iloprost - a first-line European League Against Rheumatism (EULAR)-recommended choice for the treatment of scleroderma (SSc)-related digital vasculopathy - requires repeated treatment cycles of 6 hours per day in a hospital setting. During the infusion, patient mobility is considerably restricted due to the size and fixity of traditional syringe pumps. The aim of this study was to evaluate the satisfaction level of patients and nurses, after the introduction of a new portable syringe pump (Infonde(®), Italfarmaco S.p.A., Milan, Italy) at the Department of Rheumatology, Magenta Hospital, Milan, Italy. Thirty-four consecutive SSc patients receiving stable therapy with iloprost, previously administered with a fixed pump, were treated using the portable Infonde(®) pump. Patients (n=34) and nurses (n=4) were asked to answer a nine- and six-item questionnaire, respectively, to assess the satisfaction of the administration comparing the new device versus the previous one. The health care staff of the ward developed the questionnaire, and the response scores ranged from 0 (fixed device better) to 10 (portable device better); thus a score >5 indicates a preference for Infonde(®). Patients' answers indicated a preference towards the new portable syringe pump, versus the previous fixed pump. Questionnaires administered to patients generated a total of 306 responses, with over 95% of the responses in the range 8-10, of which 89% had a score equal to 10. The responses of nurses showed a score equal to 10 in 100% cases. No significant adverse events were recorded, indicating no change in the tolerability profile of the drug. Iloprost administration with Infonde(®) pump was preferred by both patients and health care professionals, and was well tolerated. The possibility to perform daily activities and the freedom of movement suggest a positive impact of Infonde(®) on the treatment, with a potential favorable effect on the quality of life of

  5. Electron beam irradiations of polypropylene syringe barrels and the resulting physical and chemical property changes

    Science.gov (United States)

    Abraham, Ann C.; Czayka, M. A.; Fisch, M. R.

    2010-01-01

    Mechanical, thermal, chemical decomposition and electron spin resonance (ESR) methods were used to study electron beam irradiated polypropylene syringe barrels that were irradiated to a total fractionated dose of 0, 20, 40, 60, and 80 kGy (in steps of 20 kGy). Dose mapping was conducted to determine dose to and through the syringe barrel. Analysis of these data indicated that degradation of the polypropylene syringes increased with an increase in electron beam irradiation.

  6. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  7. Sterile pyuria: a forgotten entity

    OpenAIRE

    Goonewardene, Sanchia; Persad, Raj

    2015-01-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results.

  8. Sterile pyuria: a forgotten entity.

    Science.gov (United States)

    Goonewardene, Sanchia; Persad, Raj

    2015-10-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results.

  9. Sterility assurance of medical products

    International Nuclear Information System (INIS)

    Dierksheide, W.C.

    1977-01-01

    The present methods of regulating medical devices under the Food, Drug and Cosmetic Act in the United States of America are outlined. Reference is made to the position of drugs sterilized by irradiation. Surgical sutures and surgical dressings are regulated as drugs. Some details are given of proposed changes in the Act. The subject is further discussed under the headings: sterility assurance, and biocompatibility. (U.K.)

  10. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  11. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  12. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  13. Radiation sterilization of buckwheat flour

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao; Muramatsu, Nobuyuki; Oohinata, Hiroshi; Ohara, Tadahiko; Oh-ike, Terui; Matsuhashi, Tetsujiro.

    1989-01-01

    For buckwheat noodle in which taste is important and its main material, buckwheat flour, the ordinary sterilization by heating or ozone cannot be applied. The number of the bacteria sticking to buckwheat flour is much more as compared with that of wheat flour, and is 10 5 -10 7 per 1 g. The effective countermeasures are not yet found. Also noxious insects are apt to infect buckwheat flour. It has been known that radiation is effective for the sterilization of flavorings. In this study, the microorganism contamination of buckwheat flour and sterilization dose, the change of taste and properties after irradiation, and the capability of storage were examined, and the results are reported. The bacteria in buckwheat flour were mostly Erwinia which forms yellow colonies, and is plant-parasitic bacteria having sugar fermentation function, and also some Enterobacer, Klebsiella and Aspergillus were found. When gamma ray was irradiated on buckwheat flour, it was sterilized to less than 10 3 per 1 g bacteria at the dose of 5 kGy, and microorganisms were almost sterilized at 10 kGy. With the electron beam of 3 MeV, the effect of sterilization somewhat decreased. The noodle-making property of irradiated buckwheat flour, and the taste and storage capability of the noodle of irradiated flour were tested. (K.I.)

  14. Impact of syringe size on the performance of infusion pumps at low flow rates.

    Science.gov (United States)

    Schmidt, Nadia; Saez, Claudia; Seri, Istvan; Maturana, Andrés

    2010-03-01

    To evaluate the impact of syringe size on start-up delay and the time to reach 50% and 90% of target flow rates, using two commercially available syringe infusion pumps at infusion rates of < or =1 mL/hr. Two syringes (Terumo) of different size (10-mL and 50-mL), using two syringe infusion pumps (Pump A, Terumo Terufusion Infusion Pump TE-331; and Pump B, Braun Perfusor Compact S) were studied. Effective fluid delivery was measured at 0.4 mL/hr, 0.8 mL/hr, and 1.0 mL/hr for the initial 60 mins, using the gravimetric method. Instant flow was calculated as volume difference for every 1-min interval per minute. Start-up delay was defined as time in minutes of 0 flow from the start of infusion. Syringe placement, bubble removal, infusion line priming, and positioning were standardized for all measurements, using new syringes and infusion lines. Each experiment was repeated six times. Statistical analysis was performed, using a nonparametric test (Mann-Whitney U test). None. None. None. Using the 50-mL syringe, the start-up delay was consistently higher and the time to reach 50% and 90% of target flow were significantly longer, independent of which syringe infusion pump was used. At every flow rate studied, the pumps did not reach the target flow rate before 60 mins with the 50-mL syringe. With the 10-mL syringe, target flow rate was achieved before 20 mins for both pumps. Our findings demonstrate a clinically relevant impact of syringe size on syringe infusion pump performance at low flow rates. The time to reach 50% and 90% of target flow are significantly longer, using the 50-mL syringe compared with the 10-mL syringe, and the time to reach 50% of target flow is independent of the longer start-up delay. Based on our findings, we speculate that smaller syringe sizes and higher infusion rates are preferable for continuous drug infusions, particularly when prompt establishment of the drug effect is critical.

  15. Impact of Drug Formulation Variables on Silicone Oil Structure and Functionality of Prefilled Syringe System.

    Science.gov (United States)

    Shi, Galen H; Gopalrathnam, Ganapathy; Shinkle, Sharon L; Dong, Xia; Hofer, Jeffrey D; Jensen, Eric C; Rajagopalan, Natarajan

    2018-01-01

    Use of prefilled syringes to self-administer biologics via subcutaneous administration provides convenience to patients. The barrel interior of prefilled syringes is typically coated with silicone oil for lubrication to aid plunger movement at the time of administration. This study intended to evaluate the impact of formulation variables on the silicone oil on the barrel interior surface. Characterization techniques including syringe glide force, break loose force, Schlieren imaging, contact angle, inductively coupled plasma spectrometry, and thin film interference reflectometry were used in assessing the interactions. Data indicated that formulation variables such as pH, buffer/tonicity agent type and concentration, and surfactant present in the formulation can effect silicone oil lubrication of prefilled syringes, leading to changes in functional properties of the syringe over time. Syringe samples containing acetate and histidine buffers showed an increase in glide force at accelerated storage temperature conditions, but the change was minimal at 5 °C. The samples with the highest glide force correlated with the presence of mannitol in combination with sodium acetate buffer. Sodium chloride had lesser impact on glide force than mannitol. Samples with higher glide force exhibited a substantial change in the silicone oil layer of the syringe, as observed with Schlieren imaging, as well as a significant reduction in surface hydrophobicity, as demonstrated through contact angle measurement. These data indicated that the structure of the siliconized surface can change over time in contact with different formulations. During formulation development of drug products in prefilled syringes, in addition to potential impact on molecule stability, the selection of formulation variables should also be guided by assessing the impact to syringe functionality with the glide force as one of the key parameters. LAY ABSTRACT: Self-administering drug products packaged in prefilled

  16. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  17. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  18. Is crime associated with over-the-counter pharmacy syringe sales? Findings from Los Angeles, California.

    Science.gov (United States)

    Stopka, Thomas J; Geraghty, Estella M; Azari, Rahman; Gold, Ellen B; DeRiemer, Kathryn

    2014-03-01

    More than 50,000 new HIV infections occur annually in the United States. Injection drug users represent twelve percent of incident HIV infections each year. Pharmacy sales of over-the-counter (OTC) syringes have helped prevent HIV transmission among injection drug users in many states throughout the United States. However, concerns exist among some law enforcement officials, policymakers, pharmacists, and community members about potential links between OTC syringe sales and crime. We used a geographic information system and novel spatial and longitudinal analyses to determine whether implementation of pharmacy-based OTC syringe sales were associated with reported crime between January 2006 and December 2008 in Los Angeles Police Department Reporting Districts. We assessed reported crime pre- and post-OTC syringe sales initiation as well as longitudinal associations between crime and OTC syringe-selling pharmacies. By December 2008, 9.3% (94/1010) of Los Angeles Police Department Reporting Districts had at least one OTC syringe-selling pharmacy. Overall reported crime counts and reported crime rates decreased between 2006 and 2008 in all 1010 Reporting Districts. Using generalized estimating equations and adjusting for potential confounders, reported crime rates were negatively associated with OTC syringe sales (adjusted rate ratio: 0.89; 95% confidence interval: 0.81, 0.99). Our findings demonstrate that OTC pharmacy syringe sales were not associated with increases in reported crime in local communities in Los Angeles during 2006-2008. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Inhibitory Activities of Alkyl Syringates and Related Compounds on Aflatoxin Production.

    Science.gov (United States)

    Furukawa, Tomohiro; Iimura, Kurin; Kimura, Taichi; Yamamoto, Toshiyoshi; Sakuda, Shohei

    2016-06-07

    Inhibitors of aflatoxin production of aflatoxigenic fungi are useful for preventing aflatoxin contamination in crops. As methyl syringate weakly inhibits aflatoxin production, aflatoxin production inhibitory activities of additional alkyl syringates with alkyl chains from ethyl to octyl were examined. Inhibitory activity toward aflatoxin production of Aspergillus flavus became stronger as the length of the alkyl chains on the esters became longer. Pentyl, hexyl, heptyl, and octyl syringates showed strong activity at 0.05 mM. Heptyl and octyl parabens, and octyl gallate also inhibited aflatoxin production as strongly as octyl syringate. Alkyl parabens and alkyl gallates inhibit the complex II activity of the mitochondrial respiration chain; thus, whether alkyl syringates inhibit complex II activity was examined. Inhibitory activities of alkyl syringates toward complex II also became stronger as the length of the alkyl chains increased. The complex II inhibitory activity of octyl syringate was comparable to that of octyl paraben and octyl gallate. These results suggest that alkyl syringates, alkyl parabens, and alkyl gallates, including commonly used food additives, are useful for aflatoxin control.

  20. Inhibitory Activities of Alkyl Syringates and Related Compounds on Aflatoxin Production

    Directory of Open Access Journals (Sweden)

    Tomohiro Furukawa

    2016-06-01

    Full Text Available Inhibitors of aflatoxin production of aflatoxigenic fungi are useful for preventing aflatoxin contamination in crops. As methyl syringate weakly inhibits aflatoxin production, aflatoxin production inhibitory activities of additional alkyl syringates with alkyl chains from ethyl to octyl were examined. Inhibitory activity toward aflatoxin production of Aspergillus flavus became stronger as the length of the alkyl chains on the esters became longer. Pentyl, hexyl, heptyl, and octyl syringates showed strong activity at 0.05 mM. Heptyl and octyl parabens, and octyl gallate also inhibited aflatoxin production as strongly as octyl syringate. Alkyl parabens and alkyl gallates inhibit the complex II activity of the mitochondrial respiration chain; thus, whether alkyl syringates inhibit complex II activity was examined. Inhibitory activities of alkyl syringates toward complex II also became stronger as the length of the alkyl chains increased. The complex II inhibitory activity of octyl syringate was comparable to that of octyl paraben and octyl gallate. These results suggest that alkyl syringates, alkyl parabens, and alkyl gallates, including commonly used food additives, are useful for aflatoxin control.

  1. Effects of syringe material and silicone oil lubrication on the stability of pharmaceutical proteins.

    Science.gov (United States)

    Krayukhina, Elena; Tsumoto, Kouhei; Uchiyama, Susumu; Fukui, Kiichi

    2015-02-01

    Currently, polymer-based prefillable syringes are being promoted to the pharmaceutical market because they provide an increased break resistance relative to traditionally used glass syringes. Despite this significant advantage, the possibility that barrel material can affect the oligomeric state of the protein drug exists. The present study was designed to compare the effect of different syringe materials and silicone oil lubrication on the protein aggregation. The stability of a recombinant fusion protein, abatacept (Orencia), and a fully human recombinant immunoglobulin G1, adalimumab (Humira), was assessed in silicone oil-free (SOF) and silicone oil-lubricated 1-mL glass syringes and polymer-based syringes in accelerated stress study. Samples were subjected to agitation stress, and soluble aggregate levels were evaluated by size-exclusion chromatography and verified with analytical ultracentrifugation. In accordance with current regulatory expectations, the amounts of subvisible particles resulting from agitation stress were estimated using resonant mass measurement and dynamic flow-imaging analyses. The amount of aggregated protein and particle counts were similar between unlubricated polymer-based and glass syringes. The most significant protein loss was observed for lubricated glass syringes. These results suggest that newly developed SOF polymer-based syringes are capable of providing biopharmaceuticals with enhanced physical stability upon shipping and handling. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  2. Radiation: A means of sterilization

    International Nuclear Information System (INIS)

    Mukherjee, R.N.

    1975-01-01

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market

  3. Sterilization of mentally retarded persons.

    Science.gov (United States)

    Van der Merwe, J V; Roux, J P

    1987-08-01

    South Africa's Abortion and Sterilization Act No 2 (1975) authorizes sterilization for severely retarded women provided the procedure is performed in a state hospital, certified by 2 medical practitioners (1 a psychiatrist), and the parent or guardian gives informed consent. Since 1975, 152 sterilizations (140 female, 12 male) have been performed under the provisions of this Act at Pretoria's H F Verwoerd Hospital. 92% of the patients were under 20 years of age. The majority were classified as profoundly or severely retarded (74) or moderately severely retarded (68). There were 20 patients with Down's syndrome and 22 with cerebral palsy. Hysterectomy was the method of choice in the 109 women in whom menstrual hygiene was a pertinent factor; the remaining 31 women were sterilized by tubal ligation. 98% of the parents or guardians of hysterectomy acceptors surveyed were satisfied with their decision and its outcome. Several indicated their daughter was more calm, cooperative, productive, and less irritable once relieved of her menstrual periods. A multidisciplinary team approach to the decision making process and the individualization of each case are essential to protect the rights of the mentally retarded. Factors such as the psychological trauma likely to result from pregnancy and childbirth, an inability to use contraception, and unsuitability to rear a child must be demonstrated. To ensure that legislation pertaining to the sterilization of the mentally retarded does not lead to abuse, inputs from the mental health professions are required.

  4. User preference for a portable syringe pump for iloprost infusion

    Directory of Open Access Journals (Sweden)

    Laria A

    2015-05-01

    Full Text Available Antonella Laria,1 Alfredo Maria Lurati,1 Katia Angela Re,1 Maria Grazia Marrazza,1 Daniela Mazzocchi,1 Alberto Farina,2 Magda Scarpellini,1 1Department of Rheumatology, Fornaroli Hospital, Magenta, Milan, Italy; 2Medical Affairs Department, Italfarmaco S.p.A., Cinisello Balsamo, Milan, Italy Purpose: Administration of intravenous iloprost – a first-line European League Against Rheumatism (EULAR-recommended choice for the treatment of scleroderma (SSc-related digital vasculopathy – requires repeated treatment cycles of 6 hours per day in a hospital setting. During the infusion, patient mobility is considerably restricted due to the size and fixity of traditional syringe pumps. The aim of this study was to evaluate the satisfaction level of patients and nurses, after the introduction of a new portable syringe pump (Infonde®, Italfarmaco S.p.A., Milan, Italy at the Department of Rheumatology, Magenta Hospital, Milan, Italy. Patients and methods: Thirty-four consecutive SSc patients receiving stable therapy with iloprost, previously administered with a fixed pump, were treated using the portable Infonde® pump. Patients (n=34 and nurses (n=4 were asked to answer a nine- and six-item questionnaire, respectively, to assess the satisfaction of the administration comparing the new device versus the previous one. The health care staff of the ward developed the questionnaire, and the response scores ranged from 0 (fixed device better to 10 (portable device better; thus a score >5 indicates a preference for Infonde®. Results: Patients' answers indicated a preference towards the new portable syringe pump, versus the previous fixed pump. Questionnaires administered to patients generated a total of 306 responses, with over 95% of the responses in the range 8–10, of which 89% had a score equal to 10. The responses of nurses showed a score equal to 10 in 100% cases. No significant adverse events were recorded, indicating no change in the tolerability

  5. The Washington Needle Depot: fitting healthcare to injection drug users rather than injection drug users to healthcare: moving from a syringe exchange to syringe distribution model

    Directory of Open Access Journals (Sweden)

    Glickman Andrea

    2010-01-01

    Full Text Available Abstract Needle exchange programs chase political as well as epidemiological dragons, carrying within them both implicit moral and political goals. In the exchange model of syringe distribution, injection drug users (IDUs must provide used needles in order to receive new needles. Distribution and retrieval are co-existent in the exchange model. Likewise, limitations on how many needles can be received at a time compel addicts to have multiple points of contact with professionals where the virtues of treatment and detox are impressed upon them. The centre of gravity for syringe distribution programs needs to shift from needle exchange to needle distribution, which provides unlimited access to syringes. This paper provides a case study of the Washington Needle Depot, a program operating under the syringe distribution model, showing that the distribution and retrieval of syringes can be separated with effective results. Further, the experience of IDUs is utilized, through paid employment, to provide a vulnerable population of people with clean syringes to prevent HIV and HCV.

  6. Leakage of Oxygen from Blood and Water Samples Stored in Plastic and Glass Syringes

    Science.gov (United States)

    Scott, Peter V.; Horton, J. N.; Mapleson, W. W.

    1971-01-01

    Theory and experiment showed that samples of blood and water stored in 2-ml and 5-ml syringes made of polypropylene, polystyrene, or S.A.N. co-polymer exchanged oxygen with their surroundings. In the first hour the exchange was due mainly to equilibration with the plastic of the syringe and only in small degree to permeation through the plastic. With high initial tension or with blood of low haemoglobin concentration the exchange can result in errors in Po2 of up to 6% in two minutes and 16% in 30 to 60 minutes. With all-glass syringes the exchange was much slower but, even so, after 24 hours was important in all but a few of 18 interchangeable glass syringes. Therefore unless analysis can be started immediately all-glass syringes are to be preferred, and for prolonged storage even these should be selected. PMID:5565518

  7. Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator

    CERN Document Server

    Tyler, D K

    2002-01-01

    The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

  8. Pre-filled syringes: a review of the history, manufacturing and challenges.

    Science.gov (United States)

    Sacha, Gregory; Rogers, J Aaron; Miller, Reagan L

    2015-01-01

    Pre-filled syringes are convenient devices for the delivery of parenteral medications. They are small which makes them easy to carry and are dependable for delivering a precise dose of medication. These and many other reasons are leading to their growth in the pharmaceutical market. There are a number of review articles that describe the advantages and disadvantages of pre-filled syringes. However, there are few journal articles that present information on their manufacturing and challenges. The intent of this review article is to provide information on the history of the pre-filled syringe, methods of their manufacture, methods of filling syringes as a drug product and to examine the types of syringes available. This type of knowledge can familiarize the formulation scientist with the choices available and their possible challenges.

  9. Neutrinos in a Sterile Throat

    CERN Document Server

    Gripaios, Ben Matthew

    2007-01-01

    We consider field-theoretic models of a warped extra dimension with multiple throats, in which fermions that are singlets of the Standard Model gauge group propagate in a separate throat from the Standard Model fields, which we call the sterile throat. The singlets mix with Standard Model fields via interactions localized on the UV brane that connects the two throats. This leads to three, light, mostly-active, Majorana neutrinos via a higher-dimensional see-saw mechanism, together with Kaluza-Klein towers of mostly-sterile neutrinos, whose scale is set by the warp factor in the sterile throat and can be very low if the throat is deep. We suggest that a model of this kind may explain all the neutrino data, reconciling the LSND result with astrophysical constraints.

  10. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  11. Transgenic technologies to induce sterility

    Directory of Open Access Journals (Sweden)

    Wimmer Ernst A

    2009-11-01

    Full Text Available Abstract The last few years have witnessed a considerable expansion in the number of tools available to perform molecular and genetic studies on the genome of Anopheles mosquitoes, the vectors of human malaria. As a consequence, knowledge of aspects of the biology of mosquitoes, such as immunity, reproduction and behaviour, that are relevant to their ability to transmit disease is rapidly increasing, and could be translated into concrete benefits for malaria control strategies. Amongst the most important scientific advances, the development of transgenic technologies for Anopheles mosquitoes provides a crucial opportunity to improve current vector control measures or design novel ones. In particular, the use of genetic modification of the mosquito genome could provide for a more effective deployment of the sterile insect technique (SIT against vector populations in the field. Currently, SIT relies on the release of radiation sterilized males, which compete with wild males for mating with wild females. The induction of sterility in males through the genetic manipulation of the mosquito genome, already achieved in a number of other insect species, could eliminate the need for radiation and increase the efficiency of SIT-based strategies. This paper provides an overview of the mechanisms already in use for inducing sterility by transgenesis in Drosophila and other insects, and speculates on possible ways to apply similar approaches to Anopheles mosquitoes.

  12. Sterile neutrino constraints from cosmology

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, Georg G.

    2012-01-01

    The presence of light particles beyond the standard model's three neutrino species can profoundly impact the physics of decoupling and primordial nucleosynthesis. I review the observational signatures of extra light species, present constraints from recent data, and discuss the implications of po...... of possible sterile neutrinos with O(eV)-masses for cosmology....

  13. Establishment of a sterilization dose

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    Factors that impact on product bioburden (population of diable microorganisms on or in product and/or sterile barrier system) are: Raw materials, components, product design and size, manufacturing process, manufacturing equipment, manufacturing environment and manufacturing location. Presented lecture describes all these factors in details

  14. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  15. Sterilization In Protective Trade Policies

    OpenAIRE

    寺崎, 克志; Katsushi, Terasaki; 経営学部経営学科

    2007-01-01

    Under a government budget constraint export subsidies automatically sterilize distortions caused by import tariffs, i.e., without the cost of the trade policy implementation the policy mix of export subsidies and import tariffs with budget constraint makes the economy effective.

  16. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  17. The provision of non-needle/syringe drug injecting paraphernalia in the primary prevention of HCV among IDU: a systematic review

    Directory of Open Access Journals (Sweden)

    Ahmed Syed

    2010-11-01

    Full Text Available Abstract Background Sharing drug injecting paraphernalia other than needles and syringes (N/S has been implicated in the transmission of Hepatitis C virus (HCV among injecting drug users (IDU. We aimed to determine whether the provision of sterile non-N/S injecting paraphernalia reduces injecting risk behaviours or HCV transmission among IDU. Methods A systematic search of seven databases and the grey literature for articles published January 1989-February 2010 was undertaken. Thirteen studies (twelve observational and one non-randomized uncontrolled pilot intervention were identified and appraised for study design and quality by two investigators. Results No studies examined the association between the provision of non-N/S injecting paraphernalia and incident HCV infection. One cross-sectional study found that individuals who frequently, compared to those who infrequently, used sterile cookers and water, were less likely to report prevalent HCV infection. Another found no association between the uptake of sterile non-N/S injecting paraphernalia and self-reported sharing of this paraphernalia. The remaining observational studies used attendance at needle and syringe exchange programmes (NSP or safer injection facilities (SIF that provided non-N/S injecting paraphernalia as a proxy measure. Eight studies presented adjusted odds ratios, ranging from 0.3 to 0.9, suggesting a reduced likelihood of self-reported sharing of non-N/S injecting paraphernalia associated with use of NSP or SIF. There was substantial uncertainty associated with these estimates however. Three unadjusted studies reported a reduction in the prevalence of sharing of non-N/S injecting paraphernalia over time among NSP users. Only one study reported an adjusted temporal trend in the prevalence of sharing non-N/S injecting paraphernalia, finding higher rates among non-NSP users than NSP users at each time point, and a greater reduction in sharing among non-NSP than NSP users over

  18. 45 CFR 96.73 - Sterilization.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  19. Reversal of sterilization by microsurgical technique.

    Science.gov (United States)

    Gaspari, A L; Ortensi, A; Parlangeli, V; Pellizzari, G; Setti, C; Lania, M

    1988-01-01

    Tubal sterilization techniques that spare the fimbriae and cause the least amount of tubal destruction offer the best chance for reversal of sterilization. Patients seeking reversal of sterilization should be carefully selected. Surgical technique and equipment are important factors in reversal procedures; microsurgical techniques are shown to be more effective than macroscopic techniques.

  20. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  1. Microwave Sterilization and Depyrogenation System

    Science.gov (United States)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  2. KEBERHASILAN PENETRASI BAHAN PIT & FISSURE SEALANT KE DALAM FISURA MENGGUNAKAN SYRINGE BLUE MICRO TIPS DAN SYRINGE WHITE MINI BRUSH TIPS (LAPORAN PENELITIAN

    Directory of Open Access Journals (Sweden)

    Avy Permata Sari

    2015-07-01

    Full Text Available The aim of this study was to know the success and differences of pit & fissure sealant materal penetration of composite resin type (UltraSeal XT Plus into fissure by using syringe blue micro tips and syringe white mini brush tips in fissure closure efforts for caries prevention of permanent teeth. The study was conducted to 30 maxillary first premolar, using syring blue micro tips, and 30 maxilary first premolar using syringw white mini brush tips. The samples, then, were made smears and observed by optic microscope with 300 times magnification. The result of this stuy showed that mean of pit & fissure sealant material penetration of composite resin type into fissure by using blue micro tips was (67.93 ± 13.09%. By using syringe white mini brush tips was (92.96 ± 6.18%. With t-test, it showed a significant difference (t = 9.84, p<0,01.

  3. Evaluation of syringe shield effectiveness in handling radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Cho Yong-In

    2015-01-01

    Full Text Available The purpose of this study was to evaluate the effectiveness of the radiation shield of radionuclide syringes and the personal dose equivalent by performing a simulation of radionuclides used in nuclear medicine diagnosis. In order to evaluate the dose depending on the distance between the radiation source and the ICRU sphere against the thickness of the shielding device, the distance at which a nuclear medicine worker may inadvertently come into contact with radiation from the radiation source was set at 0 cm to 30 cm according to the thickness of the shield, thus fixing the ICRU sphere. For a dose evaluation, Hp(10, Hp(3, and Hp(0.07 measurable in specific depth of the ICRU were evaluated. It was found that a dose measured on skin surface of nuclear medicine workers was relatively higher, that the dose varied in relation to the thickness of the radiation shield, and that the shielding effect decreased for some radiation sources such as 67Ga and 111In. It proved necessary to increase thickness of shielding device to the radiation sources such as 67Ga and 111In. It is also considered that a study of proper shielding thickness will be needed in future.

  4. Mechanized syringe homogenization of human and animal tissues.

    Science.gov (United States)

    Kurien, Biji T; Porter, Andrew C; Patel, Nisha C; Kurono, Sadamu; Matsumoto, Hiroyuki; Scofield, R Hal

    2004-06-01

    Tissue homogenization is a prerequisite to any fractionation schedule. A plethora of hands-on methods are available to homogenize tissues. Here we report a mechanized method for homogenizing animal and human tissues rapidly and easily. The Bio-Mixer 1200 (manufactured by Innovative Products, Inc., Oklahoma City, OK) utilizes the back-and-forth movement of two motor-driven disposable syringes, connected to each other through a three-way stopcock, to homogenize animal or human tissue. Using this method, we were able to homogenize human or mouse tissues (brain, liver, heart, and salivary glands) in 5 min. From sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis and a matrix-assisted laser desorption/ionization time-of-flight mass spectrometric enzyme assay for prolidase, we have found that the homogenates obtained were as good or even better than that obtained used a manual glass-on-Teflon (DuPont, Wilmington, DE) homogenization protocol (all-glass tube and Teflon pestle). Use of the Bio-Mixer 1200 to homogenize animal or human tissue precludes the need to stay in the cold room as is the case with the other hands-on homogenization methods available, in addition to freeing up time for other experiments.

  5. Sterility of the uterine cavity

    DEFF Research Database (Denmark)

    Møller, Birger R.; Kristiansen, Frank V.; Thorsen, Poul

    1995-01-01

    In a prospective open study the sterility of the uterine cavity was evaluated in 99 women admitted for hysterectomy. The indications for hysterectomy were in most cases persistent irregular vaginal bleeding and fibromyomas of the uterus. Samples for both aerobic and anaerobic bacteria, Chlamydia ...... which may play a causative role in endometritis. The results indicate that inflammation of the uterine cavity should be evaluated by hysteroscopic examination before hysterectomy is undertaken in patients with persistent irregular vaginal bleeding. Udgivelsesdato: 1995-Mar...

  6. Signature of heavy sterile neutrinos at CEPC

    Science.gov (United States)

    Liao, Wei; Wu, Xiao-Hong

    2018-03-01

    We study the production of heavy sterile neutrino N , e+e-→N ν (ν ¯), at the Circular Electron Positron Collider (CEPC) and its l j j signal in its decay to three charged fermions. We study background events for this process which are mainly events coming from W pair production. We study the production of a single heavy sterile neutrino and the sensitivity of CEPC to the mixing of the sterile neutrino with active neutrinos. We study the production of two degenerate heavy sterile neutrinos in a low energy seesaw model by taking into account the constraints on mixings of sterile neutrinos from the neutrinoless double β decay experiment and the masses and mixings of active neutrinos. We show that CEPC under proposal has a good sensitivity to the mixing of sterile neutrinos with active neutrinos for a mass of a sterile neutrino around 100 GeV.

  7. Possibilities of radiation sterilization for re-usage of medical devices in the medical management

    International Nuclear Information System (INIS)

    Tabei, Masae; Kudo, Hisaaki; Katsumura, Yosuke

    2004-01-01

    The rule for re-usage of medical single-use devices was established in US in 2000 based on the concept of Managed Care (total management of medicare on cost, quality and patients' satisfaction) and 20-30% of those devices are re-used at present. The re-usage is conducted in not only US but also Canada, Denmark, UK, India, China etc. Standing on the viewpoint, this paper described and discussed the possibility of re-usage of the single-use devices now prohibited in Japan, possible re-sterilization, possible re-usage of hollow fiber-type hemodialyzer following γ-ray sterilization with consideration for D-values against bacteria and viruses, cost estimation of electron beam sterilization for re-usage, and radiation sterilization of waste water and plastic materials. Radiation sterilization for re-usage of medical devices was concluded possible if their materials and records for their usage processes are proper, and should be conducted in a large scale after sufficient examinations by industries/government/academia. (N.I.)

  8. Epinephrine syringe exchange events in a paediatric cardiovascular ICU: analysing the storm.

    Science.gov (United States)

    Achuff, Barbara-Jo; Achuff, Jameson C; Park, Hwan H; Moffett, Brady; Acosta, Sebastian; Rusin, Craig G; Checchia, Paul A

    2018-03-01

    Introduction Haemodynamically unstable patients can experience potentially hazardous changes in vital signs related to the exchange of depleted syringes of epinephrine to full syringes. The purpose was to determine the measured effects of epinephrine syringe exchanges on the magnitude, duration, and frequency of haemodynamic disturbances in the hour after an exchange event (study) relative to the hours before (control). Materials and methods Beat-to-beat vital signs recorded every 2 seconds from bedside monitors for patients admitted to the paediatric cardiovascular ICU of Texas Children's Hospital were collected between 1 January, 2013 and 30 June, 2015. Epinephrine syringe exchanges without dose/flow change were obtained from electronic records. Time, magnitude, and duration of changes in systolic blood pressure and heart rate were characterised using Matlab. Significant haemodynamic events were identified and compared with control data. In all, 1042 syringe exchange events were found and 850 (81.6%) had uncorrupted data for analysis. A total of 744 (87.5%) exchanges had at least 1 associated haemodynamic perturbation including 2958 systolic blood pressure and 1747 heart-rate changes. Heart-rate perturbations occurred 37% before exchange and 63% after exchange, and 37% of systolic blood pressure perturbations happened before syringe exchange, whereas 63% occurred after syringe exchange with significant differences found in systolic blood pressure frequency (p<0.001), duration (p<0.001), and amplitude (p<0.001) compared with control data. This novel data collection and signal processing analysis showed a significant increase in frequency, duration, and magnitude of systolic blood pressure perturbations surrounding epinephrine syringe exchange events.

  9. Efficacy of Syringe Filtration for the Selective Isolation of Campylobacter from Chicken Carcass Rinse.

    Science.gov (United States)

    Chon, Jung-Whan; Kim, Hong-Seok; Kim, Dong-Hyeon; Kim, Young-Ji; Sung, Kidon; Kim, Hyunsook; Seo, Kun-Ho

    2017-06-01

    We investigated the efficacy of syringe filtration for selective isolation of Campylobacter from chicken carcass rinse by combining syringe filtration with the conventional culture method. Whole chicken carcass rinses were incubated in Bolton enrichment broth, set aside or subjected to syringe filtration, and streaked on Campy-Cefex agar with or without cefoperazone antibiotic supplement. Compared with the conventional method without filtration, 0.65-μm-pore-size syringe filtration resulted in a significantly higher number of Campylobacter-positive samples (23.8 to 37.5% versus 70.0 to 72.5%; P Campylobacter (93.8% versus 6.3 to 26.3%), and a lower growth index (1 = growth of a few colonies; 2 = growth of colonies on about half of the plate; and 3 = growth on most of the plate) for competing microbiota (2.9 to 3.0 versus 1.2 to 1.4). When syringe filtration was applied, agar plates containing the antibiotic had significantly less contamination (6.3% versus 26.3%; P Campylobacter isolation rate was similar (P > 0.05). Syringe filtration combined with conventional enrichment improved the rate and selectivity of Campylobacter isolation from chicken carcasses.

  10. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  11. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  12. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  13. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Experimental bounds on sterile neutrino mixing angles

    CERN Document Server

    Ruchayskiy, Oleg

    2012-01-01

    We derive bounds on the mixing between the left-chiral ("active") and the right-chiral ("sterile") neutrinos, provided from the combination of neutrino oscillation data and direct experimental searches for sterile neutrinos. We demonstrate that the mixing of sterile neutrinos with any flavour can be significantly suppressed, provided that the angle theta_13 is non-zero. This means that the lower bounds on sterile neutrino lifetime, coming from the negative results of direct experimental searches can be relaxed (by as much as the order of magnitude at some masses). We also demonstrate that the results of the negative searches of sterile neutrinos with PS191 and CHARM experiments are not applicable directly to the see-saw models. The reinterpretation of these results provides up to the order of magnitude stronger bounds on sterile neutrino lifetime than previously discussed in the literature. We discuss the implications of our results for the Neutrino Minimal Standard Model (the NuMSM).

  15. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  16. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    Science.gov (United States)

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  17. Surgical sterilization, regret, and race: contemporary patterns.

    Science.gov (United States)

    Shreffler, Karina M; McQuillan, Julia; Greil, Arthur L; Johnson, David R

    2015-03-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4592 women ages 25-45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Stability of cyclosporine solutions stored in polypropylene-polyolefin bags and polypropylene syringes.

    Science.gov (United States)

    Li, Mengqing; Forest, Jean-Marc; Coursol, Christian; Leclair, Grégoire

    2011-09-01

    The stability of cyclosporine diluted to 0.2 or 2.5 mg/mL with 0.9% sodium chloride injection or 5% dextrose injection and stored in polypropylene-polyolefin containers or polypropylene syringes was evaluated. Intravenous cyclosporine solutions (0.2 and 2.5 mg/mL) were aseptically prepared and transferred to 250-mL polypropylene-polyolefin bags or 60-mL polypropylene syringes. Chemical stability was measured using a stability-indicating high-performance liquid chromatography (HPLC) assay. Physical stability was assessed by visual inspection and a dynamic light scattering (DLS) method. After 14 days, HPLC assay showed that the samples of i.v. cyclosporine stored in polypropylene-polyolefin bags remained chemically stable (>98% of initial amount remaining); the physical stability of the samples was confirmed by DLS and visual inspection. The samples stored in polypropylene syringes were found to contain an impurity (attributed to leaching of a syringe component by the solution) that could be detected by HPLC after 1 day; on further investigation, no leaching was detected when the syringes were exposed to undiluted i.v. cyclosporine 50 mg/mL for 10 minutes. Samples of i.v. cyclosporine solutions of 0.2 and 2.5 mg/mL diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 25 °C in polypropylene-polyolefin bags were physically and chemically stable for at least 14 days. When stored in polypropylene syringes, the samples were contaminated by an impurity within 1 day; however, the short-term (i.e., ≤10 minutes) use of the syringes for the preparation and transfer of i.v. cyclosporine solution is considered safe.

  19. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  20. Sterilization of oils: Data to support the use of a continuous point-of-use sterilizer.

    Science.gov (United States)

    Bader, F G; Boekeloo, M K; Graham, H E; Cagle, J W

    1984-08-01

    The continuous slow feed of animal and vegetable oils is frequently found to be an economically attractive method for maintaining antibiotic fermentations at a highly productive rate. The sterilization of oil feeds can present a major problem in the production plant. In this article, we present data and methodology on the kinetics of the thermal sterilization of No. 2 lard oil and soybean oil. It was also determined that dry heat sterilization condition could occur if dry spores were added to dry oil. This condition could only be partially alleviated by the addition of water to the oil. The theory and design of a small tubular coil continuous sterilizer for sterilizing oils at the point of use is also presented. This type of sterilizer is economical and versatile and simplifies control and instrument requirements. It provides a realistic alternative to the use of sterile feed tanks and sterile headers.

  1. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  2. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  3. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  4. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  5. Seeking sterile neutrinos in Finslerian cosmology

    Science.gov (United States)

    Wang, Deng; Meng, Xin-He

    2017-11-01

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H_0 tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N_eff=3.237^{+0.092}_{-0.185}, which is consistent with Δ N_eff > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N_eff=3.143^{+0.064}_{-0.066}, which favors Δ N_eff > 0 at the 1.47σ CL, and m_{ν , sterile}^eff sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration.

  6. The TRPA1 agonist, methyl syringate suppresses food intake and gastric emptying.

    Directory of Open Access Journals (Sweden)

    Min Jung Kim

    Full Text Available Transient receptor potential channel ankryn 1 (TRPA1 expressed in the gastrointestinal tract is associated with gastric motility, gastric emptying, and food intake. In this study, we investigated the effects of methyl syringate, a specific and selective TRPA1 agonist, on food intake, gastric emptying, and gut hormone levels in imprinting control region (ICR mice. The administration of methyl syringate suppressed cumulative food intake and gastric emptying. In addition, treatment with ruthenium red (RR, a general cation channel blocker, and HC-030031, a selective TRPA1 antagonist, inhibited methyl syringate-induced reduction of food intake and delayed gastric emptying in ICR mice. Methyl syringate also increased plasma peptide YY (PYY levels, but not glucagon-like peptide-1 (GLP-1 levels. The elevation in PYY was blocked by treatment with RR and HC-030031. The present findings indicate that methyl syringate regulates food intake and gastric emptying through a TRPA1-mediated pathway and, by extension, can contribute to weight suppression.

  7. Influence of Syringe Volume on Foam Stability in Sclerotherapy for Varicose Vein Treatment.

    Science.gov (United States)

    Bai, Taoping; Jiang, Wentao; Fan, Yubo

    2017-11-14

    Despite the popularity of sclerotherapy for treating varicose veins, it still exhibits various problems, such as pulmonary embolism, deep-vein thrombosis, phlebitis, and visual disorders. To investigate syringe volume influence on foam stability, obtain the foam decay rule, and provide a reference for clinics. Five types of syringes are used to prepare foam at room temperature with various liquid-gas ratios. Foam decay process experiments were performed 5 times and recorded by video. The stability indices used include drainage time, half-life, bubble diameter, bubble surface density, and drainage rate. The 30 and 2-mL syringes, respectively, recorded the highest and lowest drainage speeds. Foam drainage time and half-life, differences varied between 15 and 70 seconds, and 20 and 100 seconds, respectively. Foam bubble diameters were distributed over 0.1 to 2.0 mm with roughly 200 to 700 bubbles per square centimeter. Increased syringe volume causes the bubble diameter to increase. Thus, foam dispersion increases and foam half-life decreases; hence, foam becomes unstable. It is, thus, better to use a small syringe several times to prepare foam in clinics using segmented injections.

  8. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  9. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  10. Guidelines for pre-sterilization counseling.

    Science.gov (United States)

    1996-09-01

    The following guidelines for pre-sterilization counseling have been adopted by the Association for Voluntary Surgical Contraception: 1) emphasize that sterilization is permanent; 2) involve both partners in the decision making and present male sterilization as a viable option; 3) even if sterilization is requested, also present the range of long-term reversible methods available; 4) inform the client of failure rates associated with female sterilization and the associated risk of ectopic pregnancy; 5) emphasize that sterilization provides no protection against sexually transmitted diseases, including human immunodeficiency virus; 6) screen candidates for risk factors of post-sterilization regret, including young age and sterilization at the time of abortion or delivery; 7) fully explain the surgical procedure, preoperative instructions, surgical site, timing of the procedure, type of anesthesia, surgical risks, and length of recovery; 8) describe the possibility of unrelated changes in menstruation; 9) answer all questions; 10) discuss the positive effects on sexuality once concerns about unwanted pregnancy are removed; and 11) provide printed educational materials that the couple can review privately.

  11. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile...

  12. Direct observation of syringeal muscle function in songbirds and a parrot

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Goller, Franz

    2002-01-01

    . Under the experimental conditions used in this study, full constriction of the syringeal lumen could not be achieved by stimulating adductor muscles. Full closure may require simultaneous activation of extrinsic syringeal muscles or the supine positioning of the bird may have exerted excessive tension....... In parrots (cockatiels, Nymphicus hollandicus), direct observations show that even during quiet respiration the lateral tympaniform membranes (LTMs) are partially adducted into the tracheal lumen to form a narrow slot. Contraction of the superficial intrinsic muscle, m. syringealis superficialis, adducts...... the LTMs further into the tracheal lumen but does not close the syringeal aperture fully. The intrinsic deep muscle, m. syringealis profundus, abducts the LTMs through cranio-laterad movement of a paired, protruding half-ring. The weakly developed extrinsic m. sternotrachealis seems to increase tension...

  13. Iran eases limits on sterilization.

    Science.gov (United States)

    Roudi, N

    1991-03-01

    The government of Iran announced in November 1990, in an abrupt reversal of previous policies, the legislation of sterilization and its provision free-of-charge upon request, as well as the distribution of other contraceptive gratis. At the time of the Islamic Revolution in 1979 the government adopted a pronatalist policy, family planning programs were interrupted, legal ages of marriage were lowered, and barriers against polygamy were loosened. Iran had a 3.5% growth rate in 1990 and a total fertility rate of 6.3 lifetime births/woman. After the end of the war between Iran and Iraq in 1988, the population explosion became an obstacle to reconstruction. In 1950, the population numbered 14.2 million; by 1970 it had doubled to 28.4 million. In 1990, the country had 54.6 million people. According to a 1990 UN assessment the population will soar to 100 million by 2020. Over 8 million live in Tehran where overcrowding, traffic congestion, air pollution, and high living costs are the norm. the 1989 National Birth Control Policy Summary adopted targets to reduce the average number of lifetime births per woman to 4 children and natural growth rate to 2.3% by 2011, and to provide family planning to 24% of reproductive-age women whereby 1 million conceptions would be prevented. Indirect measures to curb fertility include raising literacy promoting the education of girls, improving the status and health conditions of women, and reducing maternal and child mortality. A media campaign has started to encourage a small family model. The low legal, social, educational, and employment status of women poses obstacles to this plan, however, the revision of laws that conflict with these goals has been urged. In other Islamic countries such as Turkey, Tunisia, Indonesia, Pakistan, and Bangladesh, female sterilization is legal. Abortion in Iran remains banned except for saving the life of the mother.

  14. Federally funded sterilization: time to rethink policy?

    Science.gov (United States)

    Borrero, Sonya; Zite, Nikki; Creinin, Mitchell D

    2012-10-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women's reproductive choices.

  15. Evaluation and validation of a bee venom sting challenge performed by a micro-syringe.

    Science.gov (United States)

    Cortellini, Gabriele; Severino, Maurizio; Francescato, Elisabetta; Turillazzi, Stefano; Spadolini, Igino; Rogkakou, Anthi; Passalacqua, Giovanni

    2012-12-01

    The honeybee sting challenge is considered a reliable procedure to evaluate the efficacy of specific immunotherapy, but it is difficult and unpractical to perform in clinical practice, because live insects are required. To assess the feasibility and reliability of a challenge test using a micro-syringe, and compared the procedure with sting challenge. Patients on bee venom immunotherapy and without systemic reactions at field sting were enrolled. They underwent a sting challenge with live bee, and large local reactions were assessed up to 48 hours. Those patients displaying systemic reactions at the sting challenge were excluded from the syringe challenge for ethical reasons. The syringe challenge was done by injecting 0.5 μL fresh unfiltered bee venom at 2 mm depth (the length of the sting left by a bee). The same follow-up as at the first challenge was performed. Bee-specific immunoglobulin E (IgE) and tryptase were measured after each challenge. Nineteen patients underwent the sting challenge with live bees. Four had immediate systemic reactions (urticaria or asthma) and were excluded from the second challenge. The remaining 15 patients with large local reaction underwent the syringe challenge. No significant difference was seen in the maximum area of the large local reactions between the challenge with live bees and the syringe challenge. Also, no change was seen in tryptase and specific antibodies. This preliminary study suggests that the micro-syringe challenge with honeybee venom is feasible and produces results indistinguishable from those of the traditional sting challenge. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. Syringe-vacuum microfluidics: A portable technique to create monodisperse emulsions.

    Science.gov (United States)

    Abate, Adam R; Weitz, David A

    2011-03-16

    We present a simple method for creating monodisperse emulsions with microfluidic devices. Unlike conventional approaches that require bulky pumps, control computers, and expertise with device physics to operate devices, our method requires only the microfluidic device and a hand-operated syringe. The fluids needed for the emulsion are loaded into the device inlets, while the syringe is used to create a vacuum at the device outlet; this sucks the fluids through the channels, generating the drops. By controlling the hydrodynamic resistances of the channels using hydrodynamic resistors and valves, we are able to control the properties of the drops. This provides a simple and highly portable method for creating monodisperse emulsions.

  17. Performance of a device to minimise radiation dose to the hands during radioactive syringe calibration

    International Nuclear Information System (INIS)

    Lindner, Oliver; Burchert, Wolfgang; Busch, Frank

    2003-01-01

    The preparation of syringes for routine applications in nuclear medicine, and in particular the calibration procedure, is associated with high radiation exposure to the hands. To reduce this radiation burden, our group developed a modified calibration procedure based on a device that we refer to as the ActivoFix, which allows syringes to be drawn up inside the dose calibrator. This study investigated the performance of the new device as compared to the usual procedure of syringe calibration with regard to the absorbed radiation dose to the hands (fingertips and middle finger bases), the precision of the calibration procedure and the time required to calibrate syringes. Fourteen experienced nuclear medicine technologists drew up syringes from an initial eluate of 8.2 GBq using the conventional technique and the new calibration procedure. All technologists had to calibrate syringes with 50 MBq, 250 MBq and 650 MBq. This sequence was repeated four times using the conventional technique and then the new procedure. The equivalent dose to the hands was measured with thermoluminescent dosimeters. The exact amount of radioactivity in the syringe and the time needed for the calibration procedure were also recorded. The reduction in equivalent dose using the new device compared with the routine procedure ranged from 8.3- to 19.6-fold (mean 14.3-fold) for the fingers of the dominant hand and from 13.6- to 40.3-fold (mean 27-fold) for those of the non-dominant hand (total mean 21.3-fold). For small volumes, time could be saved with the ActivoFix, whereas for greater volumes time was lost. The device produced less variability in calibrating doses at 250 MBq and 650 MBq. Following the ALARA principle, the new device can be recommended for syringe calibration in nuclear medicine because the use of the ActivoFix-based procedure reduces finger dose by an average factor of 21, improves the precision of calibration and reduces the filling time for small volumes. (orig.)

  18. Risk analysis of sterile production plants: a new and simple, workable approach.

    Science.gov (United States)

    Gapp, Guenther; Holzknecht, Peter

    2011-01-01

    , and delivers sound arguments for investments. Practical experience with this risk analysis, which has already been executed in several production sites in various countries, has demonstrated that it is simple, workable, and delivers valuable information. Many important pharmaceutical products need to be sterile because they are to be injected into the patient's bloodstream or muscle. Sterile means that the product must be free of microorganisms (i.e., bacteria, yeast, and moulds). A non-sterile injection or infusion could lead to very serious or even lethal effects on the patient. Therefore one of the biggest challenges in the pharmaceutical industry nowadays is still the sterile production process itself. Microorganisms are everywhere in the environment, and humans are known to be a significant source of microbial contamination of a sterile product. It is necessary to set up a very effective quality assurance system as well as many quality control analysis tools to assure the sterility of the produced vials/syringes or of the bulk material intended for later filling into vials (bulk material, e.g., 10 kg in bags or cans). Above all, to get an accurate indication of the risk of non-compliance of product quality, regulatory agencies such as the U.S. Food and Drug Administration and the updated E.U. Good Manufacturing Practice (GMP) Guide have made it mandatory to perform a risk analysis of the production process. This provides in advance valuable information about the potential risk of a product's non-compliance with product specifications and GMP requirements, in our case regarding sterility. The authors set up a new approach for a risk analysis 4 years ago; this approach stems from fundamental experience gained over the past 15 years. Several specific questions are asked regarding various topics that correlate to the sterile production line and associated quality assurance/control systems. If the answer for an item is satisfactory and the best system is in place with

  19. Community Impact of Pharmacy-Randomized Intervention to Improve Access to Syringes and Services for Injection Drug Users

    Science.gov (United States)

    Crawford, Natalie D.; Amesty, Silvia; Rivera, Alexis V.; Harripersaud, Katherine; Turner, Alezandria; Fuller, Crystal M.

    2014-01-01

    Objectives: In an effort to reduce HIV transmission among injection drug users (IDUs), New York State deregulated pharmacy syringe sales in 2001 through the Expanded Syringe Access Program by removing the requirement of a prescription. With evidence suggesting pharmacists' ability to expand their public health role, a structural, pharmacy-based…

  20. Impact of physical parameters on dosing errors due to a syringe exchange in multi-infusion therapy

    NARCIS (Netherlands)

    Snijder, Roland A.; Konings, Maurits K.; van den Hoogen, Agnes; Timmerman, Annemoon M.D.E.

    2017-01-01

    Introduction Infusion therapy is challenging and dosing errors may occur due to physical phenomena related to the infusion hardware, despite the use of accurate syringe pumps. These errors typically occur after interventions, such as the exchange of a syringe. We aimed to characterize and quantify

  1. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  2. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  3. Chemical sterilization of allograft dermal tissues.

    Science.gov (United States)

    Phipps, Abigail; Vaynshteyn, Edward; Kowalski, John B; Ngo, Manh-Dan; Merritt, Karen; Osborne, Joel; Chnari, Evangelia

    2017-12-01

    Common terminal sterilization methods are known to alter the natural structure and properties of soft tissues. One approach to providing safe grafts with preserved biological properties is the combination of a validated chemical sterilization process followed by an aseptic packaging process. This combination of processes is an accepted method for production of sterile healthcare products as described in ANSI/AAMI ST67:2011. This article describes the validation of the peracetic acid and ethanol-based (PAAE) chemical sterilization process for allograft dermal tissues at the Musculoskeletal Transplant Foundation (MTF, Edison, NJ). The sterilization capability of the PAAE solution used during routine production of aseptically processed dermal tissue forms was determined based on requirements of relevant ISO standards, ISO 14161:2009 and ISO 14937:2009. The resistance of spores of Bacillus subtilis, Clostridium sporogenes, Mycobacterium terrae, Pseudomonas aeruginosa, Enterococcus faecium, and Staphylococcus aureus to the chemical sterilization process employed by MTF was determined. Using a worst-case scenario testing strategy, the D value was calculated for the most resistant microorganism, Bacillus. The 12D time parameter determined the minimum time required to achieve a SAL of 10 -6 . Microbiological performance qualification demonstrated a complete kill of 10 6 spores at just a quarter of the full cycle time. The validation demonstrated that the PAAE sterilization process is robust, achieves sterilization of allograft dermal tissue to a SAL 10 -6 , and that in combination with aseptic processing secures the microbiological safety of allograft dermal tissue while avoiding structural and biochemical tissue damage previously observed with other sterilization methods such as ionizing irradiation.

  4. Microscope sterility during spine surgery.

    Science.gov (United States)

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  5. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards......, the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  6. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  7. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  8. Signatures of extra dimensional sterile neutrinos

    Directory of Open Access Journals (Sweden)

    Werner Rodejohann

    2014-10-01

    Full Text Available We study a large extra dimension model with active and sterile Dirac neutrinos. The sterile neutrino masses stem from compactification of an extra dimension with radius R and are chosen to have masses around eV or keV, in order to explain short-baseline anomalies or act as warm dark matter candidates. We study the effect of the sterile neutrino Kaluza–Klein tower in short-baseline oscillation experiments and in the beta spectrum as measurable by KATRIN-like experiments.

  9. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  10. Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure.

    Science.gov (United States)

    Rice, Mark J; Gravenstein, Nikolaus L; Brull, Sorin J; Morey, Timothy E; Gravenstein, Nikolaus

    2011-12-01

    Hyperinflation of the laryngeal mask airway (LMA) cuff is thought to be the etiology underlying many of the complications associated with the use of this device. Until now, there has not been a clinically acceptable method (besides direct measurement) to assure that the cuff pressure is maintained less than the recommended maximum value of 44 mm Hg (60 cm H(2)O). We inflated sizes #2 and #5 LMAs with air to 40, 60, or 120 mm Hg starting pressures, using 30- and 60-ml BD™ and B Braun™ syringes; we then allowed the syringe plungers to recoil to equilibrium before removing the syringe from the LMA inflation port. Residual LMA cuff pressures following complete passive recoil were measured and recorded. A number of combinations of syringes (30 and 60 ml) and starting pressures (40, 60, 120 mm Hg) resulted in safe residual (#2 and #5 LMA) cuff pressures of inflation pressures, these data demonstrate an efficient, practical and easy method to achieve an initial equilibrium recoil LMA cuff pressure that is less than, or very near to, the recommended upper safe limit of 44 mm Hg.

  11. Comparison between ultrasonic irrigation and syringe irrigation in clinical and laboratory studies.

    Science.gov (United States)

    Chen, Shulan; Liu, Jianxin; Dong, Gang; Peng, Bin; Yang, Pishan; Chen, Zhenggang; Yang, Fang; Guo, Dawei

    2016-01-01

    Ultrasonic irrigation and syringe irrigation were compared for their efficacy at cleaning root canal in vivo and in vitro. The in vivo study used 60 anterior teeth or premolars from 60 patients with periapical periodontitis who were randomly assigned to a syringe irrigation group (group S) or an ultrasonic irrigation group (group U). After instrumentation with a K-file using the step-back technique, the two groups received ultrasonic or syringe irrigation using 40 mL of 2.5% NaOCl respectively, followed by conventional lateral compaction. The in vitro study used 60 extracted single-canal premolars, which were also divided into U and S groups, and underwent the same irrigation and compaction. Forty of them were evaluated histologically by light microscopy, and the remaining 20 by scanning electron microscopy. No difference in main root canal filling was observed between the U and S groups. Notably, group U had a larger number of obturated lateral canals than group S. Moreover, a smaller amount of organic debris and more open dentinal tubules were observed in the root canal in group U than in group S. Our findings suggest that ultrasonic irrigation has a greater capacity to clean instrumented root canals than syringe irrigation. (J Oral Sci 58, 373-378, 2016).

  12. Comparison of Epidrum, Epi‑jet, and Loss of Resistance Syringe ...

    African Journals Online (AJOL)

    2017-09-14

    Exmoor Innovations Ltd), Epi-Jet, or. LOR syringe was attached to the hub ..... Thomas PS, Gerson JI, Strong G. Analysis of human epidural pressures. Reg Anesth 1992;17:212-5. 12. Deighan M, Briain DO, Shakeban H, O'Flaherty ...

  13. Acute and life-threatening remifentanil overdose resulting from the misuse of a syringe pump.

    NARCIS (Netherlands)

    Vanneste, B; Van de Velde, M; Struys, Michel; Rex, S

    2017-01-01

    In the perioperative setting, syringe pumps are frequently used. They guarantee constant plasma levels of hypnotics, opioids, cardiovascular medication, insulin or other drugs. We present a case in which an inadvertent rapid intravenous injection of 2 mg remifentanil occurred due to the misuse of a

  14. HIV Risk Behavior among Amphetamine Injectors at U.S. Syringe Exchange Programs

    Science.gov (United States)

    Braine, Naomi; Des Jarlais, Don C.; Goldblatt, Cullen; Zadoretzky, Cathy; Turner, Charles

    2005-01-01

    The goal of this study was to compare HIV risk behaviors of amphetamine and non-amphetamine injectors at syringe exchange programs (SEP) in the United States and to identify factors associated with injection risk. This analysis is based on data from a random cross-section of participants at 13 SEPs in different parts of the country. All interviews…

  15. Sharing of Needles and Syringes among Men Who Inject Drugs: HIV Risk in Northwest Bangladesh.

    Directory of Open Access Journals (Sweden)

    M Kamal Pasa

    Full Text Available Injection drug use is prevalent in northwestern Bangladesh. We sought to explore the context of needle/syringe sharing among persons who inject drugs (PWID, examining risk exposures to blood-borne infections like the human immunodeficiency virus (HIV and hepatitis in a region where these dual epidemics are likely to expand.We used a qualitative research approach to learn about injection practices, conducting 60 in-depth interviews among PWID. We then conducted 12 focus group discussions (FGDs that generated a checklist of salient issues, and followed up with personal observations of typical days at the drug-use venues. Content and interpretative frameworks were used to analyze qualitative information and socio-demographic information, using SPSS software.We found that needle/syringe-sharing behaviours were integrated into the overall social and cultural lives of drug users. Sharing behaviours were an central component of PWID social organization. Sharing was perceived as an inherent element within reciprocal relationships, and sharing was tied to beliefs about drug effects, economic adversity, and harassment due to their drug user status. Carrying used needles/syringes to drug-use venues was deemed essential since user-unfriendly needle-syringe distribution schedules of harm reduction programmes made it difficult to access clean needles/syringes in off-hours. PWID had low self-esteem. Unequal power relationships were reported between the field workers of harm reduction programmes and PWID. Field workers expressed anti-PWID bias and judgmental attitudes, and also had had misconceptions about HIV and hepatitis transmission. PWID were especially disturbed that no assistance was forthcoming from risk reduction programme staff when drug users manifested withdrawal symptoms.Interventions must take social context into account when scaling up programmes in diverse settings. The social organization of PWID include values that foster needle-syringe

  16. Unstable housing as a factor for increased injection risk behavior at US syringe exchange programs.

    Science.gov (United States)

    Des Jarlais, Don C; Braine, Naomi; Friedmann, Patricia

    2007-11-01

    To assess variation in injection risk behavior among unstably housed/homeless injecting drug users (IDUs) across programs in a national sample of US syringe exchange programs. About 23 syringe exchange programs were selected through stratified random sampling of moderate to very large US syringe exchange programs operating in 2001-2005. Subjects at each program were randomly sampled. Risk behavior interviews were collected using audio-computer assisted self-interviewing (A-CASI). "Unstable housing/homelessness" was operationally defined as having lived "on the street or in a shanty" or "living in a shelter or single room occupancy hotel (SRO)" at any time in the 6 months prior to the interview. "Receptive sharing" was operationally defined as having injected with a needle or syringe that "had been used by someone else" in the 30 days prior to the interview. Six very large and nine moderate-to-large programs had at least 50 subjects who reported unstable housing, and these 15 programs were used in the analyses. There was considerable variation among the 15 programs in the percentages of unstably housed participants (range from 35 to 74%, P lack of significant variation in the odds ratios for increased injection risk suggests that none of the programs were "better" or "worse" at reducing injection risk behavior among unstably housed participants. Reduction in injecting risk behavior among syringe exchange participants may require greater efforts to provide stable housing or the development of dramatically new interventions to reduce injecting risk behavior among IDUs with persistent unstable housing.

  17. Radiation sterilization of animal farm sewage

    International Nuclear Information System (INIS)

    Rosiak, J.; Perkowski, J.; Pekala, W.

    1984-01-01

    Influence of irradiation on organisms appearing in farm sewage has been discussed. Practical examples of employing the radiation to sterilization of municipal wastes and liquid sewage from the industrial swine farms have been presented. (author)

  18. How to make a sterile helper.

    Science.gov (United States)

    Downing, Philip A; Cornwallis, Charlie K; Griffin, Ashleigh S

    2017-01-01

    The sterile worker castes found in the colonies of social insects are often cited as archetypal examples of altruism in nature. The challenge is to explain why losing the ability to mate has evolved as a superior strategy for transmitting genes into future generations. We propose that two conditions are necessary for the evolution of sterility: completely overlapping generations and monogamy. A review of the literature indicates that when these two conditions are met we consistently observe the evolution of sterile helpers. We explain the theory and evidence behind these ideas, and discuss the importance of ecology in predicting whether sterility will evolve using examples from social birds, mammals, and insects. In doing so, we offer an explanation for the extraordinary lifespans of some cooperative species which hint at ways in which we can unlock the secrets of long life. © 2016 WILEY Periodicals, Inc.

  19. Encapsulation process sterilizes and preserves surgical instruments

    Science.gov (United States)

    Montgomery, L. C.; Morelli, F. A.

    1964-01-01

    Ethylene oxide is blended with an organic polymer to form a sterile material for encapsulating surgical instruments. The material does not bond to metal and can be easily removed when the instruments are needed.

  20. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  1. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study.

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter; Sedrakyan, Art

    2015-10-13

    To compare the safety and efficacy of hysteroscopic sterilization with the "Essure" device with laparoscopic sterilization in a large, all-inclusive, state cohort. Population based cohort study. Outpatient interventional setting in New York State. Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. We identified 8048 patients undergoing hysteroscopic sterilization and 44,278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, Psterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures should be discussed with patients for informed decisions making. © Mao et al 2015.

  2. Cosmological and astrophysical implications of sterile neutrinos

    Science.gov (United States)

    Petraki, Kalliopi

    The discovery of neutrino masses suggests that the Standard Model should be supplemented with new gauge-singlet fermions, often called sterile neutrinos. The interplay among the new couplings introduced in the Standard Model can accommodate the neutrino oscillation data for a variety of choices: the new particles can be extremely heavy and practically unobservable, or they can be light, in which case they can solve several long-standing puzzles. It has been shown, for example, that sterile neutrinos in some range of masses can account for dark matter, their emission from a supernova can explain pulsar kicks, arid their decays can play an important role in the formation of the first stars. Though indirect, these clues indicate that sterile neutrinos can be the minimal solution to a variety of unsolved problems. This emphasizes the importance of investigating further the consequences of these new degrees of freedom for cosmology and astrophysics. In this dissertation, I explore the possible role of sterile neutrinos of different mass scales in some cosmological and astrophysical phenomena. A minimal extension of the Higgs sector of the Standard Model, with a gauge- singlet boson coupled to sterile neutrinos, can provide a consistent framework for the theory of neutrino masses, and can produce a relic population of keV sterile neutrinos via decays of the singlet Higgs. The latter can account for the dark matter of the universe. The mechanism operates around the electroweak scale, and has interesting consequences for the electroweak phase transition. Relic sterile neutrinos produced via decays at the electroweak scale constitute colder dark matter than those produced via other previously suggested mechanisms. The primordial thermal content of dark matter has important implications for the formation of cosmic structures, such as clusters and galaxies. The assessment of the relevant properties suggests that sterile neutrinos produced at the electroweak scale are a

  3. Ethylene Oxide Gas Sterilization of Medical Devices.

    Science.gov (United States)

    Shintani, Hideharu

    2017-01-01

     Ethylene oxide gas is an agent in the sterilization of medical devices due to its effectiveness and compatibility with most materials. The advantages and disadvantages, as well as its recommended uses, are explored in this review article. The variables and their relevance on process optimization are described, the types of processing cycles are detailed and emphasis is given to the design and validation of the sterilization process.

  4. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  5. Radiation sterilization of medical devices; Radiacyjna sterylizacja sprzetu medycznego

    Energy Technology Data Exchange (ETDEWEB)

    Kaluska, I.; Stuglik, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs.

  6. 21 CFR 880.2800 - Sterilization process indicator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by a...

  7. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  8. Probability of pregnancy after sterilization: a comparison of hysteroscopic versus laparoscopic sterilization.

    Science.gov (United States)

    Gariepy, Aileen M; Creinin, Mitchell D; Smith, Kenneth J; Xu, Xiao

    2014-08-01

    To compare the expected probability of pregnancy after hysteroscopic versus laparoscopic sterilization based on available data using decision analysis. We developed an evidence-based Markov model to estimate the probability of pregnancy over 10 years after three different female sterilization procedures: hysteroscopic, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation. Parameter estimates for procedure success, probability of completing follow-up testing and risk of pregnancy after different sterilization procedures were obtained from published sources. In the base case analysis at all points in time after the sterilization procedure, the initial and cumulative risk of pregnancy after sterilization is higher in women opting for hysteroscopic than either laparoscopic band or bipolar sterilization. The expected pregnancy rates per 1000 women at 1 year are 57, 7 and 3 for hysteroscopic sterilization, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation, respectively. At 10 years, the cumulative pregnancy rates per 1000 women are 96, 24 and 30, respectively. Sensitivity analyses suggest that the three procedures would have an equivalent pregnancy risk of approximately 80 per 1000 women at 10 years if the probability of successful laparoscopic (band or bipolar) sterilization drops below 90% and successful coil placement on first hysteroscopic attempt increases to 98% or if the probability of undergoing a hysterosalpingogram increases to 100%. Based on available data, the expected population risk of pregnancy is higher after hysteroscopic than laparoscopic sterilization. Consistent with existing contraceptive classification, future characterization of hysteroscopic sterilization should distinguish "perfect" and "typical" use failure rates. Pregnancy probability at 1 year and over 10 years is expected to be higher in women having hysteroscopic as compared to laparoscopic sterilization. Copyright © 2014

  9. Radiation sterilization of aseptically manufactured products.

    Science.gov (United States)

    Fairand, Barry P; Fidopiastis, Niki

    2010-01-01

    This paper discusses an approach for establishing a sterilization dose for an aseptically processed product after the product is in its final packaged state, in other words, terminal sterilization. It applies to aseptic processes where the fill/finish operation is conducted in a closed system using isolator or restricted access barrier technology, that is, no human intervention. The example that is given in this paper uses gamma radiation as the sterilizing agent. Other forms of radiation such as high-energy electrons or X-rays also could serve as the sterilizing agent. The proposed approach involves irradiation of the aseptically processed product at very low doses of radiation, which is possible due to the extremely low levels of bioburden that may be present on the product following a fill/finish operation. Rather than sacrificing a large number of product units that may be required to obtain a statistically significant sampling of the product for bioburden analysis and other test purposes, the test unit is a surrogate consisting of actual pharmaceutical product that was inoculated with a highly radiation-resistant micro-organism. Selection of the microorganism was based on analysis of a library of environmental monitoring data taken from the aseptic area. Because of microbial diversity between different aseptic processing facilities, selection of the test microorganism would depend on the aseptic area under study. The approach that is discussed in this paper addresses selection and preparation of the surrogate, test of sterility of the surrogate following irradiation, determination of the radiation resistance of the test microorganism, and application of the approach to calculate a sterilization dose that is less than 10 kGy. At this low dose, it may be possible to terminally sterilize radiation-sensitive pharmaceutical products, for example, those in liquid form. Additional studies are warranted to determine the general applicability of the proposed approach.

  10. Sterilization Performance and Material Compatibility of Sterilizer for Dental Instruments using RF Oxygen Plasma

    Science.gov (United States)

    Sakai, Yasuhiro; Liu, Zhen; Hayashi, Nobuya; Goto, Masaaki

    2015-09-01

    The sterilization performance and material compatibility of low-pressure RF plasma sterilization method for dental instruments were investigated. RF electrode used in this experiment has been optimized for sterilization of dental instruments. The vial-type biological indicator (BI) simulating tiny space of dental instrument was used for evaluation of the sterilization performance. The pressure in the stainless chamber was fixed at 60 Pa. Sterilization of BI was achieved in shortest time 40 min at 80 W, and the sterilization effect was confirmed using three BIs. Light emission spectra of oxygen plasma indicated that production of atomic oxygen and excited oxygen molecule are maximum at pressure of 20 Pa and 200 Pa, respectively. Sterilization results of BIs indicated that successful rate increases with the oxygen pressure towards 200 Pa. Therefore, the excited oxygen molecule is deduced to be a major factor of the sterilization of BI. Surface morphology of dental instruments such as diamond bar was evaluated using scanning electron microscope (SEM). The deterioration of fine crystals of diamond bar has not observed after the plasma irradiation for 120 min with RF input power was 60W and pressure was 200 Pa.

  11. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  12. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America.

    Science.gov (United States)

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35-13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights

  13. Legal implications of single-use medical device reprocessing.

    Science.gov (United States)

    Larose, Emily

    2013-01-01

    Over 10 years ago, the Public Health Agency of Canada released the results of a nation-wide survey of hospitals that demonstrated that the reuse of single-use medical devices was widespread in Canadian healthcare institutions. In this article, the author discusses the reuse and reprocessing of these devices, as well as the risks this practice presents. She then goes on to outline the legal implications of reusing single-use devices. Copyright © 2013 Longwoods Publishing.

  14. Single-use flexible ureteropyeloscopy: a systematic review.

    Science.gov (United States)

    Davis, N F; Quinlan, M R; Browne, C; Bhatt, N R; Manecksha, R P; D'Arcy, F T; Lawrentschuk, N; Bolton, D M

    2017-11-24

    Data assessing the effectiveness of single-use flexible ureteropyeloscopy (FURS) are limited. This study evaluates and compares single-use FURS with conventional reusable FURS. A systematic search using electronic databases (Pubmed and Embase) was performed for studies evaluating single-use FURS in the setting of urinary tract stone disease. Outcome measures included a comparative evaluation of their mechanical, optical and clinical outcomes. Eleven studies on 466 patients met inclusion criteria. In vitro comparative data were available on three single-use flexible ureteropyeloscopes (LithoVue™, Polyscope™ and SemiFlex™) and clinical data were available on two (LithoVue™ and Polyscope™). The overall stone-free rate and complication rate associated with single-use FURS was 87 ± 15% and 9.3 ± 9%, respectively. There were no significant differences in procedure duration, stone size, stone clearance and complication rates when single-use FURS and reusable FURS were compared (duration: 73 ± 27 versus 74 ± 13 min, p = 0.99; stone size: 1.36 ± 0.2 versus 1.34 ± 0.18 cm, p = 0.93; stone-free rate: 77.8 ± 18 versus 68.5 ± 33%, p = 0.76; complication rate 15.3 ± 10.6 versus 15 ± 1.6%, p = 0.3). Single-use FURS demonstrates comparable efficacy with reusable FURS in treating renal calculi. Further studies on clinical efficacy and cost are needed to determine whether single-use FURS will reliably replace its reusable counterpart.

  15. Reducing single-use plastic shopping bags in the USA.

    Science.gov (United States)

    Wagner, Travis P

    2017-12-01

    In the USA, local governments have the primary responsibility to manage MSW. However, local governments lack the authority to explicitly shift costs or responsibility back onto the producer for specific problem wastes. A particularly problematic waste for local governments is the single-use plastic bag. In 2014, in the USA, 103.465 billion single-use plastic shopping bags were consumed. Because of their extremely low recyclability rate, plastic bags remain a significant source of land-based litter and marine debris and impair stormwater management systems. They also reduce the effectiveness of automated recycling systems. In response, local governments increasingly have adopted a variety of measures specifically intended to reduce the store-level consumption of single-use shopping bags in 5 major categories: bans, imposition of fees and taxes, establishing minimum product design of bags, requiring consumer education, and mandating retailer take-back programs. As of September 2017, there were 271 local governments in the USA with plastic bag ordinances covering 9.7% of the nation's population. The majority (95%) of the ordinances is a ban on single-use plastic bags; 56.9% of these bans also include a mandatory fee on paper and/or reusable bags. For the fee-based ordinances, the mode is $0.10 per bag; every tax/fee ordinance allows retailers to retain some or all the collected fee. As local governments continue to increase their actions on plastic bags, 11 states have enacted laws to prohibit local governments from regulating single-use plastic bags. Because of the success with single-use bags, local governments are also enacting similar ordinances on single-use expanded polystyrene consumer products and other single-use plastic products. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Trend Analyses of Users of a Syringe Exchange Program in Philadelphia, Pennsylvania: 1999-2014.

    Science.gov (United States)

    Maurer, Laurie A; Bass, Sarah Bauerle; Ye, Du; Benitez, José; Mazzella, Silvana; Krafty, Robert

    2016-12-01

    This study examines trends of injection drug users' (IDUs) use of a Philadelphia, Pennsylvania, syringe exchange program (SEP) from 1999 to 2014, including changes in demographics, drug use, substance abuse treatment, geographic indicators, and SEP use. Prevention Point Philadelphia's SEP registration data were analyzed using linear regression, Pearson's Chi square, and t-tests. Over time new SEP registrants have become younger, more racially diverse, and geographically more concentrated in specific areas of the city, corresponding to urban demographic shifts. The number of new registrants per year has decreased, however syringes exchanged have increased. Gentrification, cultural norms, and changes in risk perception are believed to have contributed to the changes in SEP registration. Demographic changes indicate outreach strategies for IDUs may need adjusting to address unique barriers for younger, more racially diverse users. Implications for SEPs are discussed, including policy and continued ability to address current public health threats.

  17. Costs of a Hospital-Based, Ready-To-Use Syringe Delivery Programme

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Vand, S; Lisby, M

    2017-01-01

    with a conventional delivery programme at day surgery and endoscopy departments at a large university hospital. Methods: The cost analysis used the hospital perspective and developed an “activity-based costing” model to assess the costs of medicine- handling activities. The model was calibrated with six-month data......Objective: The risk of errors in the medication administration process is high. Applications of pre lled syringes may improve patient safety but could be more costly. The objective of this study was to assess the additional costs of a ready-to-use syringe delivery programme in comparison...... cost is likely to provide improvements in the quality of the administrative process, patient safety and staff satisfaction....

  18. Direct observation of syringeal muscle function in songbirds and a parrot

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Goller, Franz

    2002-01-01

    . In parrots (cockatiels, Nymphicus hollandicus), direct observations show that even during quiet respiration the lateral tympaniform membranes (LTMs) are partially adducted into the tracheal lumen to form a narrow slot. Contraction of the superficial intrinsic muscle, m. syringealis superficialis, adducts......The role of syringeal muscles in controlling the aperture of the avian vocal organ, the syrinx, was evaluated directly for the first time by observing and filming through an endoscope while electrically stimulating different muscle groups of anaesthetised birds. In songbirds (brown thrashers......, Toxostoma rufum, and cardinals, Cardinalis cardinalis), direct observations of the biomechanical effects of contraction largely confirm the functions of the intrinsic syringeal muscles proposed from indirect studies. Contraction of the dorsal muscles, m. syringealis dorsalis (dS) and m. tracheobronchialis...

  19. Syringe-feeding as a novel delivery method for accurate individual dosing of probiotics in rats

    DEFF Research Database (Denmark)

    Tillmann, Sandra; Wegener, Gregers

    2017-01-01

    Probiotic administration to rodents is typically achieved using oral gavage or water bottles, but both approaches may compromise animal welfare, bacterial viability, dosing accuracy, or ease of administration. Oral gavage dosing may induce stress, especially when given daily over several weeks...... leftovers or clogging of the bottle further threaten the reliability of this method. To date, no method has been described that can provide non-stressful precise dosing of probiotics or prebiotics in individual rats. In accordance with the 3R principles (replace, reduce, refine), we propose syringe......-feeding as a refinement method for simple yet accurate administration of probiotics. Animals hereby voluntarily consume the solution directly from a syringe held into their home cage, thereby enabling controlled dosing of individual animals. This method requires a short training phase of approximately 3 days, but is very...

  20. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  1. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  2. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  3. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  4. Stability of busulfan solutions in polypropylene syringes and infusion bags as determined with an original assay.

    Science.gov (United States)

    Guichard, Nicolas; Bonnabry, Pascal; Rudaz, Serge; Fleury-Souverain, Sandrine

    2017-11-15

    The stability of busulfan solution in 0.9% sodium chloride and stored in polypropylene syringes or infusion bags was evaluated. Busulfan solutions (0.54 mg/mL) were prepared and transferred to 50-mL polypropylene syringes and 100- and 500-mL polypropylene infusion bags and stored at 2-8 and 23-27 °C. Chemical stability was measured using a stability-indicating, ultrahigh performance liquid chromatography coupled to mass spectrometry method. The stability of busulfan was assessed by measuring the percentage of the initial concentration remaining at the end of each time point of analysis. The initial busulfan concentration was defined as 100%. Stability was defined as retention of at least 90% of the initial busulfan concentration. A visual inspection of the samples for particulate matter, clarity, and color without instrumentation of magnification was conducted at each time point of analysis. The visual inspection demonstrated no influence of the storage container when busulfan infusions diluted in 0.9% sodium chloride injection were stored at 23-27 °C. No color change or precipitate was observed at this temperature; however, a rapid decrease of the busulfan content in all containers stored at room temperature was observed. Busulfan in syringes was chemically stable for 12 hours, while busulfan in infusion bags (100 and 500 mL) was stable only for 3 hours at 23-27 °C. Busulfan 0.54-mg/mL solution in 0.9% sodium chloride injection was physically and chemically stable for 30 hours when stored in 50-mL polypropylene syringes at 2-8 °C and protected from light. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  5. Housing Instability among People Who Inject Drugs: Results from the Australian Needle and Syringe Program Survey

    OpenAIRE

    Topp, Libby; Iversen, Jenny; Baldry, Eileen; Maher, Lisa

    2012-01-01

    High rates of substance dependence are consistently documented among homeless people, and are associated with a broad range of negative outcomes among this population. Investigations of homelessness among drug users are less readily available. This study examined the prevalence and correlates of housing instability among clients of needle syringe programs (NSPs) via the Australian NSP Survey, annual cross-sectional seroprevalence studies among NSP attendees. Following self-completion of a bri...

  6. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  7. Antimicrobial Effect of Ozone Made by KP Syringe of High-Frequency Ozone Generator.

    Science.gov (United States)

    Prebeg, Domagoj; Katunarić, Marina; Budimir, Ana; Pavelić, Božidar; Šegović, Sanja; Anić, Ivica

    2016-06-01

    The aim of this study was to evaluate in vitro the antibacterial effect of ozone on suspension of three different bacteria inoculated in prepared canals of extracted human teeth. Ozone was produced by special KP syringe of high frequency ozone generator Ozonytron (Biozonix, München, Germany) from aspirated atmospheric air by dielectric barrier discharge and applied through the tip of the syringe to the prepared root canal. The microorganisms used were Enterococcus faecalis , Staphylococcus aureus and Staphylococcus epidermidis . However, none of the methods was 100% effective against the three bacterial types in suspension. Application of ozone significantly decreased the absolute count of microorganisms (89.3%), as well as the count of each type of bacteria separately ( Staphylococcus aureus 94.0%; Staphylococcus epidermidis 88.6% and Enterococcus faecalis 79.7%). Ozone generated by KP syringe was statistically more effective compared to NaOCl as positive control, for Staphylococcus aureus and Staphylococcus epidermidis . The absolute count of Enterococcus faecalis was statistically decreased without a statistically significant difference between the tested group and positive control, respectively. Among the three types of bacteria in suspension, KP probe had the lowest antimicrobial effect against Enterococcus faecalis .

  8. The prescription of insulin pen devices versus syringes for older people with diabetes.

    Science.gov (United States)

    Shaghouli, Amna A; Shah, Baiju R

    2009-07-01

    Insulin pen devices are easier to use and lead to better treatment adherence than syringes. This study sought to determine factors associated with the decision to prescribe insulin pen devices rather than syringes for older patients initiating insulin therapy. A population-based study examined all Ontario, Canada residents > or = 66 years old who received a first prescription for insulin between 1998 and 2006 (n = 47,810). Associations between demographic/clinical factors and the use of pen devices for insulin delivery were determined. Seventy-two percent of patients began insulin therapy using pen devices for insulin delivery, increasing from 46% in 1998 to 86% in 2006. Insulin initiation by a specialist was positively associated with the use of pen devices (odds ratio [OR] 2.24, 95% confidence interval [CI] 2.08-2.40), whereas long-term care residence (OR 0.51, 95% CI 0.49-0.54) and initiation during hospitalization (OR 0.74, 95% CI 0.71-0.78) were negatively associated. Insulin pen devices were used by most patients starting insulin, but a substantial proportion of patients continued to be prescribed syringes for insulin delivery. The use of pen devices was positively associated with specialist care and negatively associated with insulin initiation during hospitalization. Increasing physicians' awareness of the benefits of pen devices to facilitate patient self-management could further increase their use and improve diabetes care.

  9. Federal funding for syringe exchange in the US: Explaining a long-term policy failure.

    Science.gov (United States)

    Showalter, David

    2018-03-08

    The United States prohibited federal funding for syringe exchange programs for people who inject drugs nearly continuously from 1988 to 2015, despite growing scientific evidence, diminishing AIDS-related controversy, and tens of thousands of deaths from injection-related AIDS. This study investigates the political and institutional bases of this long-term failure to support lifesaving public policy. This study draws on national, regional, and local media coverage, archival sources, and semi-structured, in-depth interviews with 6 long-time syringe exchange researchers and activists from California. I use case-oriented process tracing methods to explain the persistence and reform of the federal funding ban. Though previous studies focus on the symbolic clash between conservative morality and empirical science, I find that changing demographic and regional inequalities in the effects of the AIDS epidemic and dynamics produced by the federal structure of US government were more important factors in the creation and persistence of the funding ban. The persistence and eventual repeal of the ban on federal funding for syringe exchange was a product of the changing demographic, geographic, and political effects of the AIDS epidemic within the federal structure of US government, rather than a consequence of intractable morality politics. These contextual dynamics continue to shape AIDS and public health policy at all levels of government. Copyright © 2018. Published by Elsevier B.V.

  10. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  11. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  12. Radiation Fusion Technology for Sewage Sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H. [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2011-05-15

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  13. The impact of citrate introduction at UK syringe exchange programmes: a retrospective cohort study in Cheshire and Merseyside, UK

    Directory of Open Access Journals (Sweden)

    Wareing Michelle

    2007-12-01

    Full Text Available Abstract Background In 2003, it became legal in the UK for syringe exchange programmes (SEPs to provide citrate to injecting drug users to solubilise heroin. Little work has been undertaken on the effect of policy change on SEP function. Here, we examine whether the introduction of citrate in Cheshire and Merseyside SEPs has altered the number of heroin/crack injectors accessing SEPs, the frequency at which heroin/crack injectors visited SEPs and the number of syringes dispensed. Methods Eleven SEPs in Cheshire and Merseyside commenced citrate provision in 2003. SEP-specific data for the six months before and six months after citrate was introduced were extracted from routine monitoring systems relating to heroin and crack injectors. Analyses compared all individuals attending pre and post citrate and matched analyses only those individuals attending in both periods (defined as 'longitudinal attenders'. Non-parametric tests were used throughout. Results Neither new (first seen in either six months period nor established clients visited SEPs more frequently post citrate. New clients collected significantly less syringes per visit post citrate, than pre citrate (14.5,10.0; z = 1.992, P Conclusion The introduction of citrate did not negatively affect SEP attendance. 'Longitudinal attenders' visited SEPs more frequently post citrate, providing staff with greater opportunity for intervention and referral. As the number of syringes they collected each visit remained unchanged the total number of clean syringes made available to this group of injectors increased very slightly between the pre and post citrate periods. However, new clients collected significantly less syringes post citrate than pre citrate, possibly due to staff concerns regarding the amount of citrate (and thus syringes to dispense safely to new clients. These concerns should not be allowed to negatively impact on the number of syringes dispensed.

  14. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  15. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  16. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  17. SOX. Search for sterile neutrinos with Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mikko [Institut fuer Experimentalphysik, Universitaet Hamburg (Germany); Collaboration: BOREXINO-Collaboration

    2016-07-01

    Several observed anomalies in the neutrino sector could be explained by a 4th (sterile) neutrino with a squared mass difference in the order of 1 eV{sup 2} to the other three standard neutrinos. This hypothesis can be tested with an artificial kCi antineutrino (Ce-144/Pr-144) source deployed near or inside a large low background detector like Borexino. The SOX project (short baseline neutrino oscillation with Borexino) aims for the detection of sterile neutrinos and offers the almost unique possibility to observe the characteristic antineutrino oscillation pattern within the detector. The talk summarizes this concept and shows the sensitivities for the possible phases of the experiment.

  18. Solar neutrino detectors as sterile neutrino hunters

    Science.gov (United States)

    Pallavicini, Marco; Borexino-SOX Collaboration; Agostini, M.; Altenmüller, K.; Appel, S.; Atroshchenko, V.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; Cloué, O.; Cribier, M.; D'Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Durero, M.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Gschwender, M.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jany, A.; Jedrzejczak, K.; Jeschke, D.; Jonquères, N.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Ortica, F.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Reinert, Y.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Veyssière, C.; Vishneva, A.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2017-09-01

    The large size and the very low radioactive background of solar neutrino detectors such as Borexino at the Gran Sasso Laboratory in Italy offer a unique opportunity to probe the existence of neutrino oscillations into new sterile components by means of carefully designed and well calibrated anti-neutrino and neutrino artificial sources. In this paper we briefly summarise the key elements of the SOX experiment, a program for the search of sterile neutrinos (and other short distance effects) by means of a 144Ce-144Pr anti-neutrino source and, possibly in the medium term future, with a 51Cr neutrino source.

  19. Efficacy of syringe-irrigation topical therapy and the influence of the middle turbinate in sinus penetration of solutions.

    Science.gov (United States)

    Wawginiak, Guilherme Henrique; Balsalobre, Leonardo; Kosugi, Eduardo Macoto; Mangussi-Gomes, João Paulo; Samaniego, Raul Ernesto; Stamm, Aldo Cassol

    Topical therapies are the best postoperative treatment option for chronic rhinosinusitis, especially those with high volume and pressure, such as the squeeze bottles. However, they are not an available option in Brazil, where irrigation syringes are used. To investigate the efficacy of topical sinonasal therapy with syringe and the influence of the middle turbinate on this process METHODS: Intervention study in training models (S.I.M.O.N.T.). After standard dissection, three interventions were performed (Nasal Spray 4 puffs, 60-mL syringe and 240-mL Squeeze Bottle) with normal and Sutured Middle Turbinate. Images of each sinus were captured after the interventions, totalizing 144 images. The images were classified by 10 evaluators according to the amount of residual volume from zero to 3, with zero and 1 being considered poor penetration and 2 and 3, good penetration. The 1440 evaluations were used in this study. Considering all middle turbinate situations, the amount of good penetrations were 8.1% for Spray; 68.3% for Syringe, and 78.3% for Squeeze (pirrigation with a 60-mL syringe was more effective than that with nasal spray. The status of the middle turbinate proved to be fundamental and influenced topical therapy. Irrigation with syringe was as effective as the squeeze bottle when the middle turbinate was sutured to the nasal septum. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  20. Development of a Mechatronic Syringe Pump to Control Fluid Flow in a Microfluidic Device Based on Polyimide Film

    Science.gov (United States)

    Sek Tee, Kian; Sharil Saripan, Muhammad; Yap, Hiung Yin; Fhong Soon, Chin

    2017-08-01

    With the advancement in microfluidic technology, fluid flow control for syringe pump is always essential. In this paper, a mechatronic syringe pump will be developed and customized to control the fluid flow in a poly-dimethylsiloxane (PDMS) microfluidic device based on a polyimide laminating film. The syringe pump is designed to drive fluid with flow rates of 100 and 1000 μl/min which intended to drive continuous fluid in a polyimide based microfluidic device. The electronic system consists of an Arduino microcontroller board and a uni-polar stepper motor. In the system, the uni-polar stepper motor was coupled to a linear slider attached to the plunger of a syringe pump. As the motor rotates, the plunger pumps the liquid out of the syringe. The accuracy of the fluid flow rate was determined by adjusting the number of micro-step/revolution to drive the stepper motor to infuse fluid into the microfluidic device. With the precise control of the electronic system, the syringe pump could accurately inject fluid volume at 100 and 1000 μl/min into a microfluidic device.

  1. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  2. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  3. Comparison of bulb syringe and pulsed lavage irrigation with use of a bioluminescent musculoskeletal wound model.

    Science.gov (United States)

    Svoboda, Steven J; Bice, Terry G; Gooden, Heather A; Brooks, Daniel E; Thomas, Darryl B; Wenke, Joseph C

    2006-10-01

    Despite the fact that wound irrigation is a common surgical procedure, there are many variables, including delivery device, irrigant type, and fluid volume, that have yet to be optimized. The purpose of this study was to compare, with use of transgenic bioluminescent bacteria and standard quantitative microbiological methods, the efficacy of pulsed lavage and bulb syringe irrigation in reducing wound bacterial counts. A caprine model of a complex, contaminated musculoskeletal wound was developed with use of a bioluminescent strain of Pseudomonas aeruginosa that can be quantified. Luminescent activity was recorded as relative luminescent units with use of a photon-counting camera six hours after the wound was created and inoculated. Twelve goats were randomly assigned to either the pulsed lavage group or the bulb syringe irrigation group. Each wound was irrigated with normal saline solution in 3-L increments for a total of 9 L and was imaged after each 3-L increment. In addition, quantitative culture samples were obtained from different tissues within the wound before and after irrigation. Pulsed lavage decreased the amount of relative luminescent units by 52%, 64%, and 70% at 3, 6, and 9 L, respectively. The bulb syringe irrigation reduced the amount of relative luminescent units by 33%, 44%, and 51% at these same time-points. Significant differences in luminescence were noted between the two groups after both 6 and 9 L of irrigation (p irrigation and after irrigation were r = 0.96 and 0.83, respectively. Pulsed lavage was more effective than bulb syringe irrigation in reducing bacterial luminescence after both 6 and 9 L of irrigation. Both device and volume effects can be demonstrated with use of this model. Bioluminescent bacteria provide a method to visualize bacterial distribution and to quantify the bacteria in a wound. Pulsed lavage is a more effective and efficient method of irrigation to remove bacteria in a complex musculoskeletal wound. In the model we

  4. [Survey of methods of cleaning, decontamination, disinfection and sterilization in dental health services in tropical areas].

    Science.gov (United States)

    Clapeau, G; Decroix, B; Bakayoko-Ly, R; Varenne, B; Dosso-Hien, D; Decroix, M O

    1997-01-01

    The International Aid for Ontology (IAO) carried out this survey of hygiene in the dental health services of 5 French-speaking African countries in 1994, in association with the Faculty of Pharmaceutical and Biological Sciences of Paris. This study received support from the World Health Organization (WHO), the French Ministry for Cooperation and the European Community and the Ivory Coast Oral and Dental Hygiene and Health Committee (CIHSBD). Twenty-nine dental services from Benin (3), Burkina Faso (6), Ivory Coast (12), Mali (5), Niger (3) participated in this survey which gives an insight into the daily hygiene routines of these services. The cleaning, decontamination, disinfection and sterilization procedures for premises, dental equipment, instruments, hands and disposable items were investigated. No individual protocols are reported. Bench tops were cleaned or disinfected daily in 73% of centers and floors were cleaned or disinfected daily in 59% of centers. Walls were cleaned once per week in 44% of the centers. Hands were always washed between patients, with 68% of dental surgeons using only solid or liquid cleansing soaps and the others using antiseptic or disinfectant solutions. The dentist's chair was cleaned or disinfected daily in 68% of centers, mostly with soap (43%) or diluted bleach (23%). Vacuum equipment was cleaned with soap (50%) or diluted bleach (57%), with some surgeries using a combination of the two. Hand pieces and turbines were cleaned and disinfected after each use with alcohol (35%) or diluted bleach (26%) and were sterilized in 9% of centers. Instruments were sterilized with a Poupinel (63%), unspecified sterilizer (26%), autoclave (7%) or low temperature disinfection procedure (4%). Instruments were regularly sterilized in all centers. Single-use disposable items were often reused: 88% of centers reused gloves, 64% anesthetic cartridges and 32% disposable needles. This survey demonstrates that dentists do attempt to achieve appropriate

  5. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    preferable since they have an automatic timer for the working cycle and because they are equipped with handy containers for instruments. The pressure cooker ... Therefore dry heat sterilizers should have a time lock on the door to prevent misuse. The shelves inside must be perforated and instruments should not be tightly ...

  6. Whey powder sterilization by ionizing irradiation

    International Nuclear Information System (INIS)

    Todorovic, M.; Salatic, Z.; Markov, S.

    1988-01-01

    Whey powder was sterilized by gamma waves application. As a source of irridiation isotope 60Co was used in Institute of Nuclear sciences B oris Kidrich , Vincha-Belgrade (Yugoslavia). The applied doses were: a, b, c, d, and e Kgy. The dose d was radappertization. After whey powder irradiation no adverse changes of organoleptic properties were noticed

  7. sensitive genic male sterile (PGMS) rice

    African Journals Online (AJOL)

    user

    2011-04-18

    Apr 18, 2011 ... phosphate buffered solution; TEM, transmission electron microscope; CMS, cytoplasmic male sterile; FPR, first photo reaction; SPR, second photo reaction. production of cytotoxins which instigate apoptosis. For example in Caenorhabditis elegans, the ced genes code for cystein proteases Ced-3 and Ced-4 ...

  8. Light sterile neutrinos: Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Giunti, Carlo

    2016-07-15

    The indications in favor of the existence of light sterile neutrinos at the eV scale found in short-baseline neutrino oscillation experiments is reviewed. The future perspectives of short-baseline neutrino oscillation experiments and the connections with β-decay measurements of the neutrino masses and with neutrinoless double-β decay experiments are discussed.

  9. Detecting sterile neutrinos with KATRIN like experiments

    DEFF Research Database (Denmark)

    Riis, Anna Sejersen; Hannestad, Steen

    2011-01-01

    A sterile neutrino with mass in the eV range, mixing with bar nue, is allowed and possibly even preferred by cosmology and oscillation experiments. If such eV-mass neutrinos exist they provide a much better target for direct detection in beta decay experiments than the active neutrinos which...

  10. 21 CFR 610.12 - Sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Sterility. 610.12 Section 610.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS GENERAL... of the organisms and ensure freedom from contamination and deterioration. If the test organisms are...

  11. Gamma radiation sterilization of Bactrocera invadens (Diptera ...

    African Journals Online (AJOL)

    The African invader fly, Bactrocera invadens, an invasive pest in Africa since 2003, causes damage and poses a threat to the mango and horticultural industry. Its control is therefore needed. Sterilization of males using gamma radiation doses (25, 50 and 75 Gy) as a means of population control was investigated. Irradiation ...

  12. STERILIZATION AND DISINFECTION IN A PRIVATE CLINIC

    African Journals Online (AJOL)

    Oral examination is done with a mirror and probe. The mirror is then washed under the tap water and disinfected in 'V3 sterilizing' fluid concentrate. The probe is placed in a tray with ... Protective glasses are worn additionally to the gloves and facemask, when cavity preparation. is being performed. The handpiece is wiped.

  13. Methods of medical sterilization; Metody sterylizacji medycznej

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    Broad review of different (physical, chemical and mechanical) methods commonly used for medical materials sterilization have been performed. Among them the special attention have been played on radiosterilization. The advantages and weaknesses each of the presented method have been pointed out. 1 fig.

  14. Sterilization of heparinized cuprophan hemodialysis membranes

    NARCIS (Netherlands)

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated.

  15. Sterilization: A Conference and a Report.

    Science.gov (United States)

    Dillingham, Brint

    1978-01-01

    This article continues a series on Native American sterilization, based on a conference of the National Council of Churches' Interreligious Foundation for Community Organization (IFCO). Also included are an article and a report by the American Civil Liberties Union. (Author/RTS)

  16. Steam sterilization of air turbine dental handpieces.

    Science.gov (United States)

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem.

  17. Utilization of male sterility in forage crops

    International Nuclear Information System (INIS)

    Suginobu, Ken-ichi

    1982-01-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F 1 (AB), maintainer S 1 (C-S 1 ) and either maintainer or restorer S 1 s(D-S 1 , E-S 1 ) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F 1 (ABC) and either maintainer or restorer S 2 (D-S 2 ) are produced. In the case that D-S 2 seed production is difficult, maintainer or restorer F 1 (DE) should be produced from D-S 1 x E-S 1 . These seeds are used for commercial seed production. Seeds of hybrid F 1 (ABCD) or hybrid F 1 (ABCDE) are for practical use. (Kaihara, S.)

  18. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    rust carbon steel instruments and after the work cycle is ended instruments are dry and immediately available for use. Besides the disadvantage of chemical odour in a poorly ventilated room its major drawback is its dependence on a continuous supply of the chemical agent. Dry heat sterilization. This method has the lowest ...

  19. "We get by with a little help from our friends": Small-scale informal and large-scale formal peer distribution networks of sterile injecting equipment in Australia.

    Science.gov (United States)

    Newland, Jamee; Newman, Christy; Treloar, Carla

    2016-08-01

    In Australia, sterile needles and syringes are distributed to people who inject drugs (PWID) through formal services for the purposes of preventing blood borne viruses (BBV). Peer distribution involves people acquiring needles from formal services and redistributing them to others. This paper investigates the dynamics of the distribution of sterile injecting equipment among networks of people who inject drugs in four sites in New South Wales (NSW), Australia. Qualitative data exploring the practice of peer distribution were collected through in-depth, semi-structured interviews and participatory social network mapping. These interviews explored injecting equipment demand, access to services, relationship pathways through which peer distribution occurred, an estimate of the size of the different peer distribution roles and participants' understanding of the illegality of peer distribution in NSW. Data were collected from 32 participants, and 31 (98%) reported participating in peer distribution in the months prior to interview. Of those 31 participants, five reported large-scale formal distribution, with an estimated volume of 34,970 needles and syringes annually. Twenty-two participated in reciprocal exchange, where equipment was distributed and received on an informal basis that appeared dependent on context and circumstance and four participants reported recipient peer distribution as their only access to sterile injecting equipment. Most (n=27) were unaware that it was illegal to distribute injecting equipment to their peers. Peer distribution was almost ubiquitous amongst the PWID participating in the study, and although five participants reported taking part in the highly organised, large-scale distribution of injecting equipment for altruistic reasons, peer distribution was more commonly reported to take place in small networks of friends and/or partners for reasons of convenience. The law regarding the illegality of peer distribution needs to change so that

  20. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  1. Present status in radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Sato, Kenji

    1982-01-01

    The attempt to sterilize the disposable medical supplies of plastics and protein by radiation started as early as 1958. In the world, more than 80 such installations have been set up and operated at present. In recent years, the guarantee for sterilization has been emphasized; the trend is now for the worldwise standardization of the process control and the method of determining sterilization radiation dose. In Japan, there exist three installations equipped with 60 Co gamma -ray irradiation apparatus. The medical supplies over 20 items including artificial kidney dialyzer, injection needles and surgical stitches are radiation sterilized and practically used presently. The following matters are described: radiation sterilization facilities, sterilization process control, sterilization conditions (radiation dose), the radiation resistance of microorganisms, radiation-sterilized medical supplies. (Mori, K.)

  2. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  3. Sterility maintenance assessment of moist/wet material after steam sterilization and 30-day storage.

    Science.gov (United States)

    Moriya, Giovana Abrahão de Araújo; Graziano, Kazuko Uchikawa

    2010-01-01

    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle. The external parts of each surgical box were deliberately contaminated with Serratia marcescens and subsequently stored for 30 days. After this period, the boxes' contents were submitted to sterility tests and no growth was observed. The presence of moisture inside the surgical boxes did not interfere with maintaining their sterility.

  4. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  5. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  6. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  7. Sterility Maintenance Assessment of Moist/Wet Material After Steam Sterilization and 30-day Storage

    OpenAIRE

    Moriya,Giovana Abrahão de Araújo; Graziano,Kazuko Uchikawa

    2010-01-01

    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupt...

  8. Combined low dose local anesthetics and opioids versus single use ...

    African Journals Online (AJOL)

    2014-09-24

    Sep 24, 2014 ... stay of the patients. Therefore, reducing the side effects associated with intrathecal anesthesia is quite helpful to support better postoperative management. Combined low dose local anesthetics and opioids versus single use of LA for transurethral urological surgery: A meta‑analysis. Y Ding, M Li, L Chen1, ...

  9. Socio-Economic Status Determines Risk of Receptive Syringe Sharing Behaviors among Iranian Drug Injectors; A National Study.

    Science.gov (United States)

    Assari, Shervin; Ahmadi, Khodabakhsh; Rezazade, Majid

    2014-01-01

    Although needle and syringe sharing is one of the main routs of transmission of HIV in several countries in the middle east, very little is known about how socio-economic status of injecting drug users (IDUs) is linked to the receptive syringe sharing behaviors in these countries. To study socio-economic correlates of receptive needle and syringe sharing among IDUs in Iran. The study used data from the Unhide Risk Study, a national survey of IDUs. This study sampled 636 IDUs (91% male) via snowball sampling from eight provinces in Iran in 2009. Socio-demographic and drug use characteristics were collected. We used a logistic regression to determine factors associated with receptive needle and syringe sharing during the past 6 months. From 636 IDUs enrolled in this study, 68% (n = 434) reported receptive needle and syringe sharing behaviors in the past 6 months. Odds of receptive needle and syringe sharing in the past 6 months was lower among IDUs who were male [odds ratios (OR) = 0.29, 95% confidence interval (CI) = 0.12-0.70], had higher education (OR = 0.74, 95% CI = 0.64-0.86) but higher among those who were unemployed (OR = 4.05, 95% CI = 1.50-10.94), and were single (OR = 1.47, 95% CI = 1.02-2.11). This study presented factors associated with risk of receptive needle and syringe sharing among Iranian IDUs. This information may be used for HIV prevention and harm reduction purposes. Socio-economic status of Iranian IDUs may be closely linked to high-risk injecting behaviors among them.

  10. Socio-economic status and receptive needle and syringe sharing behaviors among Iranian Drug Injectors; a national study

    Directory of Open Access Journals (Sweden)

    Shervin eAssari

    2015-03-01

    Full Text Available Background: Although needle and syringe sharing is one of the main routs of transmission of HIV in several countries in the middle east, very little is known about how socioeconomic status of injecting drug users (IDUs is linked to the receptive syringe sharing behaviors in these countries. Aim: To study socioeconomic correlates of receptive needle and syringe sharing among IDUs in Iran.Methods: The study used data from the Unhide Risk Study, a national survey of IDUs. This study sampled 636 IDUs (91% male via snowball sampling from eight provinces in Iran in 2009. Socio-demographic and drug use characteristics were collected. We used a logistic regression to determine factors associated with receptive needle and syringe sharing during the past six months.Results: From 636 IDUs enrolled in this study, 68% (n=434 reported receptive needle and syringe sharing behaviors in the past six months. Odds of receptive needle and syringe sharing in the past six months was lower among IDUs who were male (OR=0.29, 95% CI= 0.12 to 0.70, had higher education (OR=0.74, 95% CI=0.64 to 0.86 but higher among those who were unemployed (OR=4.05, 95% CI=1.50 to 10.94, and were single (OR=1.47, 95% CI=1.02 to 2.11.Conclusion: This study presented factors associated with risk of receptive needle and syringe sharing among Iranian IDUs. This information may be used for HIV prevention and harm reduction purposes. Socioeconomic status of Iranian IDUs may be closely linked to high risk injecting behaviors among them.

  11. Socio-Economic Status Determines Risk of Receptive Syringe Sharing Behaviors among Iranian Drug Injectors; A National Study

    Science.gov (United States)

    Assari, Shervin; Ahmadi, Khodabakhsh; Rezazade, Majid

    2015-01-01

    Background: Although needle and syringe sharing is one of the main routs of transmission of HIV in several countries in the middle east, very little is known about how socio-economic status of injecting drug users (IDUs) is linked to the receptive syringe sharing behaviors in these countries. Aim: To study socio-economic correlates of receptive needle and syringe sharing among IDUs in Iran. Methods: The study used data from the Unhide Risk Study, a national survey of IDUs. This study sampled 636 IDUs (91% male) via snowball sampling from eight provinces in Iran in 2009. Socio-demographic and drug use characteristics were collected. We used a logistic regression to determine factors associated with receptive needle and syringe sharing during the past 6 months. Results: From 636 IDUs enrolled in this study, 68% (n = 434) reported receptive needle and syringe sharing behaviors in the past 6 months. Odds of receptive needle and syringe sharing in the past 6 months was lower among IDUs who were male [odds ratios (OR) = 0.29, 95% confidence interval (CI) = 0.12–0.70], had higher education (OR = 0.74, 95% CI = 0.64–0.86) but higher among those who were unemployed (OR = 4.05, 95% CI = 1.50–10.94), and were single (OR = 1.47, 95% CI = 1.02–2.11). Conclusion: This study presented factors associated with risk of receptive needle and syringe sharing among Iranian IDUs. This information may be used for HIV prevention and harm reduction purposes. Socio-economic status of Iranian IDUs may be closely linked to high-risk injecting behaviors among them. PMID:25852577

  12. Efficacy of syringe-irrigation topical therapy and the influence of the middle turbinate in sinus penetration of solutions

    Directory of Open Access Journals (Sweden)

    Guilherme Henrique Wawginiak

    Full Text Available Abstract Introduction: Topical therapies are the best postoperative treatment option for chronic rhinosinusitis, especially those with high volume and pressure, such as the squeeze bottles. However, they are not an available option in Brazil, where irrigation syringes are used. Objective: To investigate the efficacy of topical sinonasal therapy with syringe and the influence of the middle turbinate on this process Methods: Intervention study in training models (S.I.M.O.N.T.. After standard dissection, three interventions were performed (Nasal Spray 4 puffs, 60-mL syringe and 240-mL Squeeze Bottle with normal and Sutured Middle Turbinate. Images of each sinus were captured after the interventions, totalizing 144 images. The images were classified by 10 evaluators according to the amount of residual volume from zero to 3, with zero and 1 being considered poor penetration and 2 and 3, good penetration. The 1440 evaluations were used in this study. Results: Considering all middle turbinate situations, the amount of good penetrations were 8.1% for Spray; 68.3% for Syringe, and 78.3% for Squeeze (p < 0.0001. Considering all types of interventions, the Normal Middle Turbinate group had 48.2% of good penetrations and the Sutured Middle Turbinate, 55% (p = 0.01. Considering only the Sutured Middle Turbinates, there was no difference between the interventions with Syringe and Squeeze (76.3% vs. 80.4%; p = 0.27. Conclusion: Topical therapy of irrigation with a 60-mL syringe was more effective than that with nasal spray. The status of the middle turbinate proved to be fundamental and influenced topical therapy. Irrigation with syringe was as effective as the squeeze bottle when the middle turbinate was sutured to the nasal septum.

  13. Multistate outbreak of Serratia marcescens bloodstream infections caused by contamination of prefilled heparin and isotonic sodium chloride solution syringes.

    Science.gov (United States)

    Blossom, David; Noble-Wang, Judith; Su, John; Pur, Stacy; Chemaly, Roy; Shams, Alicia; Jensen, Bette; Pascoe, Neil; Gullion, Jessica; Casey, Eric; Hayden, Mary; Arduino, Matthew; Budnitz, Daniel S; Raad, Isaam; Trenholme, Gordon; Srinivasan, Arjun

    2009-10-12

    To investigate clusters of Serratia marcescens (SM) bloodstream infections (BSIs) at health care facilities in several states and determine whether contaminated prefilled heparin and isotonic sodium chloride solution (hereinafter, saline) syringes from a single manufacturer (company X) were the likely cause, we performed an outbreak investigation of inpatient and outpatient health care facilities from October 2007 through February 2008. Active case finding for clusters of SM BSIs. Information on SM BSIs was obtained, and SM blood isolates were sent to the Centers for Disease Control and Prevention (CDC). Culture specimens were taken from various lots of prefilled heparin and saline syringes by health care facilities and the CDC to test for the presence of SM. The SM isolates from syringes and blood were compared by pulsed-field gel electrophoresis. A total of 162 SM BSIs in 9 states were reported among patients at facilities using prefilled heparin and/or saline syringes made by company X. Cultures of unopened prefilled heparin and saline syringes manufactured by company X grew SM. Of 83 SM blood isolates submitted to the CDC from 7 states, 70 (84%) were genetically related to the SM strain isolated from prefilled syringes. A US Food and Drug Administration inspection revealed that company X was not in compliance with quality system regulations. A multistate outbreak of SM BSIs was associated with intrinsic contamination of prefilled syringes. Our investigation highlights important issues in medication safety, including (1) the importance of pursuing possible product-associated outbreaks suggested by strong epidemiologic data even when initial cultures of the suspected product show no contamination and (2) the challenges of medical product recalls when production has been outsourced from one company to another.

  14. [Study of the reproducibility of the sterilization process and proposal of an sterilizer requalification protocol].

    Science.gov (United States)

    Gibory, V; Robelet, A; Riou, J; Lebelle Dehaut, A-V

    2018-03-01

    Unlike EN 554, and since the publication of ISO 17665-1 standard, the user of autoclaves may use methods other than those indicated in the guidelines. Outsourcing the requalification of sterilizers by an external service provider and after observing from the previous requalification reports that the thermometric data seemed reproducible, we decided to propose and validate a validation method for the reproducibility of the sterilization process. This is to exempt from the study of the repeatability of the EN 554 standard in future requalifications. Reproducibility was studied with the sensors of the sterilization service and from the production cycles. This study was carried out in three parts. First, we checked whether our sensors were reliable. Then we evaluated the sterilization process fidelity of each sterilizer. Finally, we compared our measurements performed by the service sensors with the measurements performed by the service provider during the requalifications of the previous years. This work leads us to describe a new protocol of requalification of our sterilizers. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  15. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  16. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  17. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine fumarate...

  18. 21 CFR 872.6710 - Boiling water sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  19. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  20. 42 CFR 441.255 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a...

  1. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  2. Monitoring of steam sterilization processes in the dental office

    NARCIS (Netherlands)

    van Doornmalen, J.P.C.M.; Rietmeijer, A.G.M.; Feilzer, A.J.; Kopinga, K.

    2013-01-01

    In dental offices steam sterilization is used to prevent infection of staff and patient. The necessity of sterilization is obvious. To ensure effective sterilization processes each load has to be monitored. Based on literature and standards a state of the art concept of every load monitoring is

  3. The Coercive Sterilization of Aboriginal Women in Canada

    Science.gov (United States)

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  4. Determination of bismuth and cadmium after solid-phase extraction with chromosorb-107 in a syringe

    Energy Technology Data Exchange (ETDEWEB)

    Tokman, Nilgun; Akman, Suleyman

    2004-08-09

    The determination of bismuth and cadmium by graphite furnace atomic absorption spectrometry (GFAAS) after solid-phase extraction (SPE) on Chromosorb-107 filled in a syringe was described. To retain the analytes, the sample solution treated with and without ammonium pyrolidine dithiocarbamate (APDC) was drawn into the syringe filled with Chromosorb-107 and discharged back manually. Bismuth and cadmium were quantitatively sorbed at pH {>=} 6 irrespective of whether the analyte was complexed with APDC prior to passing through the Chromosorb-107. Analyte elements sorbed on the resin were quantitatively eluted with 3.0 M of HNO{sub 3} again drawing and discharging the eluent into the syringe and ejected it back. Optimum flow rates of sample or eluent for sorption and elution processes were 20 ml min{sup -1} for drawing and 20 ml min{sup -1} for discharging in all cases. Bismuth and cadmium were analyzed by graphite furnace atomic absorption spectrometry. The elements could be concentrated by drawing and discharging several portions of sample successively but eluting only one time. The validity of the proposed method was checked with standard reference materials (NIST SRM 1515 Apple-Leaves, CWW-TM-E Waste Water and CRM-SW Sea Water). The analyte elements were quantitatively (>95%) recovered from different matrices irrespective of treated samples with APDC. Detection limits ({delta}) were 0.8 and 1.2 {mu}g l{sup -1} for Bi and Cd, respectively. The method can be characterized with fastness, simplicity, quantitative recovery and high reproducibility.

  5. [Preference for etanercept pen versus syringe in patients with chronic arthritis. Nurse education workshop].

    Science.gov (United States)

    Garcia-Diaz, Silvia; Girabent-Farrés, Montserrat; Roig-Vilaseca, Daniel; Reina, Delia; Cerdà, Dacia; González, Marina; Torrente-Segarra, Vicenç; Fíguls, Ramon; Corominas, Hèctor

    2013-01-01

    The aims of this study are to evaluate the level of fear of post-injection pain prior to the administration, the difficulty in handling the device, and the level of satisfaction of patients using a pre-filled syringe versus an etanercept pen, as well as to evaluate the usefulness of the training given by nursing staff prior to starting with the pen, and the preferences of patients after using both devices. A prospective study was designed to follow-up a cohort of patients during a 6 months period. The data was collected using questionnaires and analyzed with SPSS 18.00. Rank and McNemar tests were performed. Statistical significance was pre-set at an α level of 0.05. A total of 29 patients were included, of whom 69% female, and with a mean age 52.5±10.9 years. Of these, 48% had rheumatoid arthritis, 28% psoriatic arthritis, 21% ankylosing spondylitis, and 3% undifferentiated spondyloarthropathy. There were no statistically significant differences either with the fear or pain or handling of the device between the syringe and the pen (P=.469; P=.812; P=.169 respectively). At 6 months, 59% of patients referred to being satisfied or very satisfied with the pen. Almost all (93%) found useful or very useful the training given by nursing staff prior to using the pen, and 55% preferred the pen over the pre-filled syringe. The etanercept pen is another subcutaneous device option for patients with chronic arthritis. According to the present study, nursing educational workshops before starting this therapy are recommended. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  6. Non-stick syringe needles: Beneficial effects of thin film metallic glass coating

    OpenAIRE

    Chu, Jinn P.; Yu, Chia-Chi; Tanatsugu, Yusuke; Yasuzawa, Mikito; Shen, Yu-Lin

    2016-01-01

    This paper reports on the use of Zr-based (Zr53Cu33Al9Ta5) thin film metallic glass (TFMG) for the coating of syringe needles and compares the results with those obtained using titanium nitride and pure titanium coatings. TFMG coatings were shown to reduce insertion forces by ?66% and retraction forces by ?72%, when tested using polyurethane rubber block. The benefits of TFMG-coated needles were also observed when tested using muscle tissue from pigs. In nano-scratch tests, the TFMG coatings ...

  7. The dynamics of gynodioecy in Plantago lanceolata L. .1. Frequencies of male-steriles and their cytoplasmic male sterility types

    NARCIS (Netherlands)

    De Haan, A.A.; Luyten, R.M.J.M.; Bakx-Schotman, Tanja; Van Damme, J.M.M.

    1997-01-01

    The maintenance of a gynodioecious breeding system (hermaphrodites and male-steriles) was studied in Plantago lanceolata. Cytoplasmic-nuclear inheritance is important in the maintenance of male-steriles. The male-sterile trait is cytoplasmically based (CMS), and male fertility can be restored by

  8. Syringe confiscation as an HIV risk factor: the public health implications of arbitrary policing in Tijuana and Ciudad Juarez, Mexico.

    Science.gov (United States)

    Beletsky, Leo; Lozada, Remedios; Gaines, Tommi; Abramovitz, Daniela; Staines, Hugo; Vera, Alicia; Rangel, Gudelia; Arredondo, Jaime; Strathdee, Steffanie A

    2013-04-01

    Female sex workers who inject drugs (FSW-IDUs) face elevated risk for HIV/STIs and constitute a key population for public health prevention. Through direct and indirect pathways including human rights violations, policing practices like syringe confiscation can compound FSW-IDU health risk and facilitate the spread of disease. We studied correlates of experiencing syringe confiscation among FSW-IDUs in northern Mexico, where formal policy allows for syringes to be available over the counter without a prescription, but police practices are often at odds with the law. FSW-IDUs reporting recent syringe sharing and unprotected sex with clients in Tijuana and Ciudad Juarez were administered surveys and HIV/STI testing. Logistic regression was used to identify correlates of syringe confiscation. Among 624 respondent FSW-IDUs, prevalence of syringe confiscation in the last 6 months was 48%. The following factors were positively associated with syringe confiscation: testing positive for HIV (adjusted odds ratio [aOR] = 2.54, 95% confidence interval [CI] = 1.11-5.80), reporting sexual abuse by police (aOR = 12.76, 95% CI = 6.58-24.72), engaging in groin injection (aOR = 1.84, 95% CI = 1.15-2.93), injecting in public (aOR = 1.64; 95% CI = 1.14-2.36), and obtaining syringes from pharmacies (aOR = 1.54; 95% CI = 1.06-2.23). Higher education level was negatively associated with syringe confiscation (aOR = 0.92, 95% CI = 0.87-0.98) as was frequent injection with clients within the last month (aOR = 0.64, 95% CI = 0.44-0.94). This analysis adds to the body of evidence linking unauthorized law enforcement actions targeting high-risk groups with HIV and other adverse health outcomes. Using a public health lens to conceptualize abuse as a structural risk factor, we advocate for multi-prong prevention, systematic monitoring, and evidence-based intervention response to deleterious police practices.

  9. Using a modified syringe technique to adjust the intracuff pressure of a laryngeal mask airway.

    Science.gov (United States)

    Hung, Kuo-Chuan; Chen, Wei-Hung; Shih, Yu-Hsuan; Yeh, Li-Ren

    2015-12-01

    Limiting the intracuff pressure of a laryngeal mask airway (LMA) to pressure of an LMA. In a preclinical study, commercially available 20-mL syringes were attached to the pilot balloon of LMAs with different preset intracuff pressures (40 cmH2O, 50 cmH2O, 60 cmH2O, 70 cmH2O, 80 cmH2O, 100 cmH2O, and 120 cmH2O). After attachment, the syringe plunger was allowed to passively rebound. If no rebound of the plunger was observed after attachment, 1 mL of air was withdrawn and the plunger was allowed to passively rebound again. This technique allowed the plunger to overcome static friction and avoid excessive deflation of the LMA cuffs. The intracuff pressure was measured using a manometer after the plunger ceased moving. In the preclinical study, the intracuff pressure was always less than or close to 60 cmH2O after adjustment using this modified syringe technique. After evaluating the performance and characteristics of the syringe in the preclinical study, we concluded that the modified syringe technique may be useful for adjusting LMA intracuff pressure effectively. Copyright © 2015. Published by Elsevier B.V.

  10. Study of radiolytic effect on residual ethylene oxide in perfusion devices for single use by using gas chromatography

    International Nuclear Information System (INIS)

    Wang Mingsuo; Teng Weifang; Liu Keliang; Feng Jixin; Su Liaoyuan

    1993-01-01

    The efficiency of the 60 Co γ-rays irradiation induced elimination reaction of residual ethylene oxide (RETO) in the perfusion devices for single use conducted with RETO gas chromatography has been studied. The observations show: 1. the splinting reaction of RETO absorbed by the infusion sets after ethylene oxide (ETO) sterilization occurred accompanied with 4 kGy irradiation, therefore the relative elimination percentage (RELP) calculated from RETO is over 90%. 2. the optimum radiation conditions are as following irradiation dose 4 kGy, dose rate 8 Gy/min, irradiation temperature 20 degree C. 3. the RETO content within medical infusion sets at 2 weeks storing time after radiation was probably controlled under 2.0 ppm. 4. the radiation chemistry mechanism of the RETO elimination reaction is discussed in relation to the primary and secondary actions of elimination reaction

  11. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    Science.gov (United States)

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  13. Energy analysis in sterilization process of food

    International Nuclear Information System (INIS)

    Lee, Dong Sun; Pyun, Yu Ryang

    1986-01-01

    A procedure was developed for predicting energy consumption of batch type thermal processing of food. From mass and energy balance equations various energy usages or losses were estimated for steam sterilization of model food system in No.301-7 can (Φ74.1 x 113.0mm) at three different temperatures. Selected models were 5 % bentonite solution for conductive food and tap water for convective food. Total steam or energy consumption was higher at 110 deg C than at two other higher temperatures (121 deg C and 130 deg C). High energy consumption at low sterilization temperature was mainly due to high bleeding steam energy and convective and radiative heat losses. Thermal energy efficiency was also disscussed. (Author)

  14. Sterilization of activated sludges by gamma radiations

    International Nuclear Information System (INIS)

    Lacroix, J.P.; Boland, M.

    1978-01-01

    The purification process of a wastewater is described. It has been found that the great amount of sludge produced, the average value being 50 g of dry matter per inhabitant and per day, contains three species of pathogen microorganims: enteroviruses, bacteria and parasite eggs and cystes and that this microbial pollution is extremely harmful to human health. Therefore in order to manipulate as well as to use activated sludges in an agriculturad soil, a strong action against pathogen microorganisms is to be taken. Various treatment of sterilization are then described such as: pasteurization, incineration, liming, composting and by gamma radiations. The treatment by gamma radiations has been found to have many advantages in comparison with the other ones. An example of a sterilization plant located in Western Germany is given. (G.C.)

  15. A search for sterile neutrinos in MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Osiecki, Thomas Henry [Univ. of Texas, Austin, TX (United States)

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm$2\\atop{23}$ and θ23 through the disappearance of vμ, MINOS is able to measure vμ → vsterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  16. Sterile neutrinos in the early universe

    Energy Technology Data Exchange (ETDEWEB)

    Malaney, R.A. (Lawrence Livermore National Lab., CA (USA)); Fuller, G.M. (California Univ., San Diego, La Jolla, CA (USA). Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  17. Laparoscopic sterilization camps--a retrospection.

    Science.gov (United States)

    Mehta, P V

    1984-04-01

    Since the Indian introduction of mass rural laparoscopic sterilization camps the procedure has proved highly acceptable, economical, speedy, and safe. Despite many couples requiring sterilization, disturbing trends have emerged in many states relating to the organization of the camps, selection of cases, pre-operative preparation, adequate experience of the operating surgeon, inadequate drugs, improper maintainence, malfunctioning of equipment, and post-operative care and follow-up. During the initial phase, it was relatively easy to draw large crowds of self-motivated acceptors; the management of these crowds in small places left much to be desired. Camps are arranged without adequate publicity through the various media. The art of laparoscopy being a highly skilled technic, Steptoe has recommended at least 1000 procedures and Phillips 500 procedures in hospitals under expert supervision, before a laparoscopist can operate independently in camps. The equipment should be properly maintained and enough spares should be at hand. For the desired projection to stabilize the birth rate at 25/1000, the sterilization camps approach through quick, safe, economical, and easy laparoscopic sterilization technic is not a dream but a reality to be experienced. The vastness of the work requires many well trained doctors in this technic, who should be given exemption from income tax if they serve the rural population; thus, the brain drain will stop, and many emigrating doctors will be able to make a living. Overall, the commitment of policy makers to satisfy the masses who want to participate in this successful program is the only hope to save the bleak future.

  18. Sperm antibody production in female sterility.

    Science.gov (United States)

    Mettler, L; Scheidel, P; Shirwani, D

    1974-01-01

    A review of the immunological implications in reproductive physiology is presented. Although attempts have been made to ascribe the antigenicity of semen to individual components, it has not been possible to isolate the human semen antigen responsible for infertility. In monkeys total ejaculates and seminal plasma have shown higher antigenicity than washed spermatozoa. In bulls some evidence of such antigens have been found in the seminal plasma. They are iron-binding proteins resembling lactoferrin. Most investigators have found no evidence for any participation of the ABO blood group antigens in cases of sterility. On the surface of human spermatozoa histo-incompatibility antigens have been detected. Transplantation antigens may be related to sterility. However, an immulogic tolerance of the maternal organism exists against the genetically foreign fetal tissue. Autoimmune spermagglutinating antibodies have been detected in the sera and in the seminal plasma of males with sterility. An obstruction of the seminal pathways may facilitate the production of such antibodies against retained sperm. Isoimmunity in females against seminal components has been shown in cases of sterility; however, fertile women have also been shown to have such conditions. In a group of infertile women spermagglutination activity was detected in 7.5% of cases. In another series of 46 cases with primary unexplained infertility agglutinating antibodies were found in 17.4%. Other investigators have also reported higher rates than the authors. The sperm immobilization test seems to be more sensitive than the agglutination test. No sera were found positive with both tests. With immunofluorescent techniques humoral sperm antibodies have been found to be the IgM and IgG fractions. Each acts on a different part of the spermatozoa. The only promising therapy against humoral sperm antibodies is avoidance of sperm contact over a long period of time. Reported results have been conflicting. Cortisone

  19. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  20. Sterilization potential of contact lens solutions

    OpenAIRE

    Dada Vijay; Mehta Manoj

    1988-01-01

    In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. ...

  1. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  2. Light Sterile Neutrinos from Large Extra Dimensions

    OpenAIRE

    Ma, Ernest; Rajasekaran, G.; Sarkar, Utpal

    2000-01-01

    An experimentally verifiable Higgs-triplet model of neutrino masses from large extra dimensions was recently proposed. We extend it to accomodate a light sterile neutrino which also mixes with the three active neutrinos. A previously proposed phenomenological model of four neutrinos (\\underline {the only viable such model now left}, in view of the latest atmospheric and solar neutrino-oscillation data) is specifically realized.

  3. Irradiation sterilization of semi-crystalline polymers

    International Nuclear Information System (INIS)

    Williams, J.; Dunn, T.; Stannett, V.

    1978-01-01

    A semi-crystalline polymer such as polypropylene, is sterilized by high energy irradiation, with the polymer containing a non-crystalline mobilizing additive which increases the free volume of the polymer, to prevent embrittlement of the polymer during and subsequent to the irradiation. The additive has a density of from 0.6 to 1.9 g/cm 3 and a molecular weight from 100 to 10,000 g/mole

  4. Psychosexual adjustment following sterilization: a prospective study on Chinese women.

    Science.gov (United States)

    Tang, C S; Chung, T K

    1997-02-01

    The present study aimed to identify significant predictors of Chinese women's psychosexual adjustment after sterilization. One hundred fifteen multiparous Chinese women, aged 25-51 years, were interviewed before and after elective laparoscopic or postpartum sterilization. Eight-seven women were also interviewed about their pshychosexual adjustment at 1 year after sterilization. Results showed that the fear of negative evaluation by others, family cohesion and adaptability, and preoperative psychological distress were robust predictors of adverse psychosexual outcome immediately and 1 year after sterilization. There was significant improvement in women's mental health following sterilization, and their sexual adjustment such as coital frequency and sexual satisfaction were not adversely affected at 1 year follow-up. Women with either elective or postpartum sterilization had similar adjustment throughout, except the latter group tended to experience more physical discomfort at 1 year follow-up. About 3.4% of the women experienced regret at 12 months after sterilization.

  5. [Essure--a novel method of sterilization].

    Science.gov (United States)

    Revel, Ariel; Nadjary, Michel; Shushan, Asher

    2008-02-01

    Essure hysteroscopic sterilization is a minimally invasive, outpatient approach to female sterilization, which avoids the possible complications of laparoscopic sterilization. This procedure has been available since 2003 in both Europe and North America. We present our experience of the first 12 cases of the procedure performed in Israel. Women who have completed their family planning were offered to consider Essure as their permanent contraception. The procedure was performed without anesthesia by the vaginoscopic technique at the hospital's outpatient clinic. Patients completed a questionnaire and were discharged immediately following the procedure. A follow-up checkup was completed after three months including three dimensional sonography, abdominal X-ray and occasional hysterosalpingogram. Twelve patients participated in the pilot group at Hadassah. The average age was 40 years (34-45) and the average number of children was 5 (4-8). The average time for the procedure was under 8 minutes. Periostial adhesions required adhesiolysis prior to insertion of the device in one patient. All patients resumed their normal activity on the same day. Our patient satisfaction survey revealed that the procedure was associated with high satisfaction levels. Sonographic and radiographic studies confirmed the good placement of the device. The Essure procedure was well tolerated by patients. The limitation is probably going to be the price of Essure, as this procedure is not covered by the 'health basket' in Israel.

  6. APSIC guidelines for disinfection and sterilization of instruments in health care facilities.

    Science.gov (United States)

    Ling, Moi Lin; Ching, Patricia; Widitaputra, Ammar; Stewart, Alison; Sirijindadirat, Nanthipha; Thu, Le Thi Anh

    2018-01-01

    The Asia Pacific Society of Infection Control launched its revised Guidelines for Disinfection and Sterilization of Instruments in Health Care Facilities in February 2017. This document describes the guidelines and recommendations for the reprocessing of instruments in healthcare setting. It aims to highlight practical recommendations in a concise format designed to assist healthcare facilities at Asia Pacific region in achieving high standards in sterilization and disinfection. The guidelines were revised by an appointed workgroup comprising experts in the Asia Pacific region, following reviews of previously published guidelines and recommendations relevant to each section. It recommends the centralization of reprocessing, training of all staff with annual competency assessment, verification of cleaning, continual monitoring of reprocessing procedures to ensure their quality and a corporate strategy for dealing with single-use and single-patient use medical equipment/devices. Detailed recommendations are also given with respect to reprocessing of endoscopes. Close working with the Infection Prevention & Control department is also recommended where decisions related to reprocessing medical equipment/devices are to be made. Sterilization facilities should aim for excellence in practices as this is part of patient safety. The guidelines that come with a checklist help service providers identify gaps for improvement to reach this goal.

  7. Sterilization by ionizing radiation comparative evaluation; Sterilizzazione mediante radiazioni e confronto con le tecniche convenzionali

    Energy Technology Data Exchange (ETDEWEB)

    Tata, A. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dip. Innovazione; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 70 % by EtO, 27% by gamma-irradiation and 3% using accelerated beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems.

  8. APSIC guidelines for disinfection and sterilization of instruments in health care facilities

    Directory of Open Access Journals (Sweden)

    Moi Lin Ling

    2018-02-01

    Full Text Available Abstract Background The Asia Pacific Society of Infection Control launched its revised Guidelines for Disinfection and Sterilization of Instruments in Health Care Facilities in February 2017. This document describes the guidelines and recommendations for the reprocessing of instruments in healthcare setting. It aims to highlight practical recommendations in a concise format designed to assist healthcare facilities at Asia Pacific region in achieving high standards in sterilization and disinfection. Method The guidelines were revised by an appointed workgroup comprising experts in the Asia Pacific region, following reviews of previously published guidelines and recommendations relevant to each section. Results It recommends the centralization of reprocessing, training of all staff with annual competency assessment, verification of cleaning, continual monitoring of reprocessing procedures to ensure their quality and a corporate strategy for dealing with single-use and single-patient use medical equipment/devices. Detailed recommendations are also given with respect to reprocessing of endoscopes. Close working with the Infection Prevention & Control department is also recommended where decisions related to reprocessing medical equipment/devices are to be made. Conclusions Sterilization facilities should aim for excellence in practices as this is part of patient safety. The guidelines that come with a checklist help service providers identify gaps for improvement to reach this goal.

  9. Targeted release of transcription factors for cell reprogramming by a natural micro-syringe.

    Science.gov (United States)

    Berthoin, Lionel; Toussaint, Bertrand; Garban, Frédéric; Le Gouellec, Audrey; Caulier, Benjamin; Polack, Benoît; Laurin, David

    2016-11-20

    Ectopic expression of defined transcription factors (TFs) for cell fate handling has proven high potential interest in reprogramming differentiated cells, in particular for regenerative medicine, ontogenesis study and cell based modelling. Pluripotency or transdifferentiation induction as TF mediated differentiation is commonly produced by transfer of genetic information with safety concerns. The direct delivery of proteins could represent a safer alternative but still needs significant advances to be efficient. We have successfully developed the direct delivery of proteins by an attenuated bacterium with a type 3 secretion system that does not require challenging and laborious steps for production and purification of recombinant molecules. Here we show that this natural micro-syringe is able to inject TFs to primary human fibroblasts and cord blood CD34 + hematopoietic stem cells. The signal sequence for vectorization of the TF Oct4 has no effect on DNA binding to its nucleic target. As soon as one hour after injection, vectorized TFs are detectable in the nucleus. The injection process is not associated with toxicity and the bacteria can be completely removed from cell cultures. A three days targeted release of Oct4 or Sox2 embryonic TFs results in the induction of the core pluripotency genes expression in fibroblasts and CD34 + hematopoietic stem cells. This micro-syringe vectorization represents a new strategy for TF delivery and has potential applications for cell fate reprogramming. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  11. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study.

    Science.gov (United States)

    Raju, T B V G; Garapati, Satish; Agrawal, Rupika; Reddy, Sridhara; Razdan, Ankur; Kumar, S Kishore

    2013-12-01

    Aim of the study was to compare 4 different methods of sterilizing endodontic files in dental practice. The present study was performed on 100 K-files, 21 mm long and of size 25. Of these, 20 files were taken as control group, and the remaining 80 files were divided into 4 groups of 20 files each and they were tested for the efficacy of sterilization with different methods: Autoclave, glass bead, glutaraldehyde and CO2 laser. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization. How to cite this article: Raju TB, Garapati S, Agrawal R, Reddy S, Razdan A, Kumar SK. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study. J Int Oral Health 2013; 5(6):108-12 .

  12. Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.

    Science.gov (United States)

    Kallmes, David F; O, Erwin; Roy, Soma Sinha; Piccolo, Richard G; Marx, William F; Lee, Jae K; Jensen, Mary E

    2003-01-01

    Percutaneous vertebroplasty procedures require relatively long durations of fluoroscopic guidance, which might lead to substantial radiation dose to operators. Specialized injection devices have been proposed to limit operator exposure. Our purpose was to compare the radiation dose to the operator's hands during vertebroplasty when using 1-cc syringes versus that when using an injection device. Radiation dosimeters were worn on the left wrist during 39 vertebroplasty injection procedures in 25 patients. Cases were alternated between the use of 1-cc syringes (19 procedures) and the use of an injection device (20 procedures). For each procedure, one dosimeter was worn throughout the procedure, both during needle placement and injection, and a second dosimeter was worn during the injection phase only. Mean doses for the whole case and mean doses for the injection procedure alone were compared between groups. Mean whole case dose was 128 +/- 161 mrem (range, 0-660 mrem) for the 1-cc syringe group versus 98 +/- 90 mrem (range, 0-340 mrem) for the injection device group (P =.23). Mean dose during injection was 100 +/- 145 mrem (range, 0-660 mrem) for the 1-cc syringe group versus 55 +/- 43 mrem (range, 0-130 mrem) for the injection device group (P =.09). Three of 19 1-cc syringe cases yielded zero dose, compared with four of 20 injection device cases. Duration of injection was markedly different between groups, with mean injection times of 4.2 and 7.5 min for 1-cc syringe and injection device cases, respectively (P device groups, respectively (P =.002). The use of an injection device significantly decreased the radiation dose to the operator's extremity per unit time of injection. However, total dose per injection was equivalent between groups because of significantly longer injection duration for the injection device cohort.

  13. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    The hazard of infectious disease transmission with tissue allografts is a major concern in tissue banking practice. Microorganisms can be introduced into grafts during tissue collection, processing and storage, but even when all these procedures are performed under a septic conditions, the possibility of fungal, bacterial or viral disease transmission of donor origin can not be excluded. Therefore, in order to minimize the risk of infectious disease transmission, several steps should be undertaken, including a careful donor screening, proper tissue processing and sterilization of tissue allografts. The risk of transmission of viral infections such as hepatitis B, C, other viruses and particularly HIV with tissue allografts is of great significance and the search for sterilizing methods which inactivate and/or highly reduce viral infectivity continues. Sterilization of tissue allografts with ionizing radiation (introduced in the mid of 1950s) is increasingly used in tissue banking practice. The effectiveness of the radiation-sterilization procedure depends on the amount of energy transferred, the number of contaminating microorganisms and their resistance to ionizing radiation (initial contamination, bioburden). Usually, spores are more resistant than vegetative forms of bacteria, some fungi may be as resistant as bacterial spores, and viruses are, in general, more resistant than bacteria. Dita concerning effectiveness of ionizing radiation to inactivate viruses (e.g. such as HBV, HCV or HIV) in tissue allografts collected from cadavers are scarce. It has been found that the dose of irradiation needed to reduce HIV load by I log10 unit (D10) is about 4.0 kGy or even 5.6 kGy. The level of infectious HIV in plasma is usually evaluated by titration of tissue culture infective dose (TCID50/ml). Taking into consideration the recommended sterility assurance level (SAL) 10-6, assuming the HIV bioburden to be 103 TCID50/ml for the state of acute infection and D10 value of 4

  14. Syringe shape and positioning relative to efficiency volume inside dose calibrators and its role in nuclear medicine quality assurance programs

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J.A.M. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Centro de Investigacao, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal)], E-mail: a.miranda@portugalmail.pt; Carrasco, M.F. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Centro de Investigacao, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Lencart, J. [Servico de Fisica Medica, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal); Bastos, A.L. [Servico de Medicina Nuclear, Instituto Portugues de Oncologia do Porto Francisco Gentil, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200072 Porto (Portugal)

    2009-06-15

    A careful analysis of geometry and source positioning influence in the activity measurement outcome of a nuclear medicine dose calibrator is presented for {sup 99m}Tc. The implementation of a quasi-point source apparent activity curve measurement is proposed for an accurate correction of the activity inside several syringes, and compared with a theoretical geometric efficiency model. Additionally, new geometrical parameters are proposed to test and verify the correct positioning of the syringes as part of acceptance testing and quality control procedures.

  15. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  16. Degradation of chitosan-based materials after different sterilization treatments

    Science.gov (United States)

    San Juan, A.; Montembault, A.; Gillet, D.; Say, J. P.; Rouif, S.; Bouet, T.; Royaud, I.; David, L.

    2012-02-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  17. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  18. Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures.

    Science.gov (United States)

    Brandi, Kristyn; Morgan, Jake R; Paasche-Orlow, Michael K; Perkins, Rebecca B; White, Katharine OʼConnell

    2018-02-01

    To compare obstetric outcomes after failed hysteroscopic and laparoscopic sterilization. This retrospective cohort study examined pregnancy outcomes including live birth, preterm birth, stillbirth, spontaneous abortion, therapeutic abortion, ectopic pregnancies, and gestational trophoblastic disease using a commercial claims administrative database for the years 2007-2013. We used a Z-test to compare pregnancy outcomes per 100 person-years based on type of sterilization. Cox proportional hazard models controlled for patient age, geographic region, urbanicity, comorbidities, and insurance type. We evaluated 997 pregnancy outcomes among 817 women from a total of 70,115 women with a history of either hysteroscopic sterilization (n=387 pregnancies/27,724 cases) or laparoscopic sterilization (n=610 pregnancies/42,391 cases). Women undergoing hysteroscopic sterilization were slightly older than, but otherwise similar to, women undergoing laparoscopic sterilization. The most common outcome was live birth, which was more likely after hysteroscopic sterilization compared with laparoscopic sterilization (adjusted hazard ratio 1.32, 95% CI 1.09-1.60). The rate of spontaneous abortion was not statistically significantly different between the two groups. Therapeutic abortion occurred more often after hysteroscopic sterilization (adjusted hazard ratio 1.49, 95% CI 1.10-2.01), whereas ectopic pregnancies occurred less often (adjusted hazard ratio 0.12, 95% CI 0.05-0.29) compared with laparoscopic sterilization. Hysteroscopic sterilization is associated with higher rates of live birth and lower rates of ectopic pregnancy compared with laparoscopic sterilization. Spontaneous abortion and preterm birth rates were similar in both groups. These data do not support an adverse effect of hysteroscopic sterilization on subsequent pregnancy outcomes.

  19. Effect of a single-use toothbrush on plaque microflora

    OpenAIRE

    Pai Vidya

    2009-01-01

    Aim: To study and compare the microbial flora of dental plaque after the use of a self-contaminated toothbrush and that of a single-use toothbrush. Materials and Methods: The study group included 40 young volunteers from Yenepoya Dental College, who were free from any systemic or oral disease. In these subjects, plaque samples were collected after 1 month use of a self-contaminated toothbrush. Each subject was given a set of 30 new toothbrushes and a toothpaste tube and instructed to use o...

  20. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    Science.gov (United States)

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated

  1. Effect of a single-use toothbrush on plaque microflora

    Directory of Open Access Journals (Sweden)

    Pai Vidya

    2009-01-01

    Full Text Available Aim: To study and compare the microbial flora of dental plaque after the use of a self-contaminated toothbrush and that of a single-use toothbrush. Materials and Methods: The study group included 40 young volunteers from Yenepoya Dental College, who were free from any systemic or oral disease. In these subjects, plaque samples were collected after 1 month use of a self-contaminated toothbrush. Each subject was given a set of 30 new toothbrushes and a toothpaste tube and instructed to use one toothbrush everyday and discard it after use. The plaque samples were collected on a weekly interval and cultured on Mitis Salivarius agar. The colonies were identified and speciated and their count was recorded. Results: Streptococcus mitis, S. mutans, S. sanguis, S. milleri and Candida were recovered from the samples. A highly significant decrease in their numbers was found after the use of a single-use toothbrush (P value 0.001. Conclusions : As a contaminated toothbrush can reintroduce microorganisms into the oral cavity, it may be a sound practice to change the toothbrush as frequently as possible.

  2. Effect of a single-use toothbrush on plaque microflora.

    Science.gov (United States)

    Pai, Vidya

    2009-01-01

    To study and compare the microbial flora of dental plaque after the use of a self-contaminated toothbrush and that of a single-use toothbrush. The study group included 40 young volunteers from Yenepoya Dental College, who were free from any systemic or oral disease. In these subjects, plaque samples were collected after 1 month use of a self-contaminated toothbrush. Each subject was given a set of 30 new toothbrushes and a toothpaste tube and instructed to use one toothbrush everyday and discard it after use. The plaque samples were collected on a weekly interval and cultured on Mitis Salivarius agar. The colonies were identified and speciated and their count was recorded. Streptococcus mitis, S. mutans, S. sanguis, S. milleri and Candida were recovered from the samples. A highly significant decrease in their numbers was found after the use of a single-use toothbrush (P value 0.001). As a contaminated toothbrush can reintroduce microorganisms into the oral cavity, it may be a sound practice to change the toothbrush as frequently as possible.

  3. Plant's sterilization rule for fertile women cited.

    Science.gov (United States)

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs.

  4. Environment and the sterile insect technique

    International Nuclear Information System (INIS)

    Nagel, P.; Peveling, R.

    2005-01-01

    The sterile insect technique (SIT) is an exceptionally promising pest control method in terms of efficacy and environmental compatibility. Assessments of environmental risks vary according to the status and origin of the target pests. The suppression or eradication of exotic pest populations with the SIT raises few environmental concerns, and these are related mainly to pre-release suppression techniques. However, the elimination of native species, or at least populations of native species, requires more detailed and complex assessments of ecological effects and consequences for biodiversity conservation. Eradication programmes provide opportunities to study these topics within the scope of both environmental impact assessments and operational monitoring programmes. (author)

  5. Sterile neutrinos and B-L symmetry

    Science.gov (United States)

    Fileviez Pérez, Pavel; Murgui, Clara

    2018-02-01

    We revisit the relation between the neutrino masses and the spontaneous breaking of the B-L gauge symmetry. We discuss the main scenarios for Dirac and Majorana neutrinos and point out two simple mechanisms for neutrino masses. In this context the neutrino masses can be generated either at tree level or at quantum level and one predicts the existence of very light sterile neutrinos with masses below the eV scale. The predictions for lepton number violating processes such as μ → e and μ → eγ are discussed in detail. The impact from the cosmological constraints on the effective number of relativistic degree of freedom is investigated.

  6. Sterile searches with Liquid Argon at FNAL

    CERN Document Server

    Raselli, Gian Luca

    2017-01-01

    A new Short Baseline Neutrino (SBN) experiment is in preparation at FNAL to definitely prove or exclude the existence of non-standard neutrino oscillations into sterile states. The program foresees the deployment along the Booster Neutrino Beam (BNB) of three detectors, all based on the liquid-argon time projection chamber technique. This technology has been taken to full maturity with ICARUS T600, which will act as far detector after the completion of the overhauling at CERN and its transportation to FNAL. The program foresees the data taking for three years.

  7. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  8. Processing laboratory of radio sterilized biological tissues

    International Nuclear Information System (INIS)

    Aguirre H, Paulina; Zarate S, Herman; Silva R, Samy; Hitschfeld, Mario

    2005-01-01

    The nuclear development applications have also reached those areas related to health. The risk of getting contagious illnesses through applying biological tissues has been one of the paramount worries to be solved since infectious illnesses might be provoked by virus, fungis or bacterias coming from donors or whether they have been introduced by means of intermediate stages before the use of these tissues. Therefore it has been concluded that the tissue allografts must be sterilized. The sterilization of medical products has been one of the main applications of the ionizing radiations and that it is why the International Organization of Atomic Energy began in the 70s promoting works related to the biological tissue sterilization and pharmaceutical products. The development of different tissue preservation methods has made possible the creation of tissue banks in different countries, to deal with long-term preservation. In our country, a project was launched in 1998, 'Establishment of a Tissue Bank in Latino america', this project was supported by the OIEA through the project INT/ 6/ 049, and was the starting of the actual Processing Laboratory of Radioesterilized Biological Tissues (LPTR), leaded by the Chilean Nuclear Energy Commission (CCHEN). This first organization is part of a number of entities compounding the Tissue Bank in Chile, organizations such as the Transplantation Promotion Corporation hospitals and the LPTR. The working system is carried out by means of the interaction between the hospitals and the laboratory. The medical professionals perform the procuring of tissues in the hospitals, then send them to the LPTR where they are processed and sterilized with ionizing radiation. The cycle ends up with the tissues return released to the hospitals, where they are used, and then the result information is sent to the LPTR as a form of feedback. Up to now, human skin has been processed (64 donors), amniotic membranes (35 donors) and pig skin (175 portions

  9. A rapid and economic in-house DNA purification method using glass syringe filters.

    Directory of Open Access Journals (Sweden)

    Yun-Cheol Kim

    Full Text Available BACKGROUND: Purity, yield, speed and cost are important considerations in plasmid purification, but it is difficult to achieve all of these at the same time. Currently, there are many protocols and kits for DNA purification, however none maximize all four considerations. METHODOLOGY/PRINCIPAL FINDINGS: We now describe a fast, efficient and economic in-house protocol for plasmid preparation using glass syringe filters. Plasmid yield and quality as determined by enzyme digestion and transfection efficiency were equivalent to the expensive commercial kits. Importantly, the time required for purification was much less than that required using a commercial kit. CONCLUSIONS/SIGNIFICANCE: This method provides DNA yield and quality similar to that obtained with commercial kits, but is more rapid and less costly.

  10. Non-stick syringe needles: Beneficial effects of thin film metallic glass coating.

    Science.gov (United States)

    Chu, Jinn P; Yu, Chia-Chi; Tanatsugu, Yusuke; Yasuzawa, Mikito; Shen, Yu-Lin

    2016-08-30

    This paper reports on the use of Zr-based (Zr53Cu33Al9Ta5) thin film metallic glass (TFMG) for the coating of syringe needles and compares the results with those obtained using titanium nitride and pure titanium coatings. TFMG coatings were shown to reduce insertion forces by ∼66% and retraction forces by ∼72%, when tested using polyurethane rubber block. The benefits of TFMG-coated needles were also observed when tested using muscle tissue from pigs. In nano-scratch tests, the TFMG coatings achieved a coefficient of friction (COF) of just ∼0.05, which is about one order of magnitude lower than those of other coatings. Finite-element modeling also indicates a significant reduction in injection and retraction forces. The COF can be attributed to the absence of grain boundaries in the TFMG coating as well as a smooth surface morphology and low surface free energy.

  11. 3D Printing Prototypes for Healthcare Professionals: Creating a Reciprocating Syringe.

    Science.gov (United States)

    Rothenberg, Steven; Abdullah, Selwan; Hirsch, Jeffrey

    2017-10-01

    3D printing (additive manufacturing) has been around since 1984, but interest in the technology has increased exponentially as it has become both accessible and inexpensive. The applications of the technology in healthcare are still being explored; however, initial forays have been encouraging. It has the potential to revolutionize the process of prototyping for healthcare professionals by democratizing the process and enhancing collaboration, making it cheaper to do iterative prototyping with little or no engineering experience. This case report details the creation of a multi-lumen reciprocating syringe with 3D printing. The product has been created and tested using a variety of publicly available resources. It provides a detailed overview of the approach and the framework required to create such a medical device. However, the implications of this report are much larger than this one product, and the fundamental ideas discussed here could be used for creating customized solutions for many healthcare problems.

  12. Failure mode and effects analysis applied to the administration of liquid medication by oral syringes

    Directory of Open Access Journals (Sweden)

    Eva María Guerra-Alia

    2017-11-01

    Full Text Available To carry out a Failure Mode and Effects Analysis (FMEA to the use of oral syringes. Methods: A multidisciplinary team was assembled within the Safety Committee. The stages of oral administration process of liquid medication were analysed, identifying the most critical and establishing the potential modes of failure that can cause errors. The impact associated with each mode of failure was calculated using the Risk Priority Number (RPN. Preventive actions were proposed. Results: Five failure modes were identified, all classified as high risk (RPN> 100. Seven of the eight preventive actions were implemented. Conclusions: The FMEA methodology was a useful tool. It has allowed to know the risks, analyse the causes that cause them, their effects on patient safety and the measures to reduce them

  13. Ensuring injection safety during measles immunization campaigns: more than auto-disable syringes and safety boxes.

    Science.gov (United States)

    Hersh, Bradley S; Carr, Richard M; Fitzner, Julia; Goodman, Tracey S; Mayers, Gillian F; Everts, Hans; Laurent, Eric; Larsen, Gordon A; Bilous, Julian B

    2003-05-15

    Measles immunization campaigns are effective elements of a comprehensive strategy for preventing measles cases and deaths. However, if immunizations are not properly administered or if immunization waste products are not safely managed, there is the potential to transmit bloodborne pathogens (e.g., human immunodeficiency virus and hepatitis B and hepatitis C). A safe injection can be defined as one that results in no harm to the recipient, the vaccinator, and the surrounding community. Proper equipment, such as the exclusive use of auto-disable syringes and safety boxes, is necessary, but these alone are not sufficient to ensure injection safety in immunization campaigns. Equally important are careful planning and managerial activities that include policy and strategy development, financing, budgeting, logistics, training, supervision, and monitoring. The key elements that must be in place to ensure injection safety in measles immunization campaigns are outlined.

  14. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  15. Reliability of laparoscopic compared with hysteroscopic sterilization at 1 year: a decision analysis.

    Science.gov (United States)

    Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J

    2011-08-01

    To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.

  16. Mechanical properties of composites as functions of the syringe storage temperature and energy dose

    Directory of Open Access Journals (Sweden)

    Fernanda Oliveira CHAVES

    2015-04-01

    Full Text Available Objective: To investigate the mechanical properties of different classifications of composites indicated for posterior application as functions of the storage condition and of the energy dose. Material and Methods: Specimens (8x2x2 mm were obtained according to the factors: I Composites (3M ESPE: Filtek P60, Filtek Z350XT, and Filtek Silorane; II Syringe storage conditions: room temperature, aged, oven, refrigerator, and freezer; and III Energy dose: 24 J/cm2 and 48 J/cm2. After photoactivation, the specimens were stored at 37ºC for 24 h. After storage, a three-point bending test was carried out in a universal testing machine at 0.5 mm/min. Flexural strength (S and flexural modulus (E were calculated. Data were analyzed by three-way ANOVA and Tukey's test (α=0.05. Results: Different storage conditions significantly affected the silorane composite for S; conversely, no effects were noted in terms of E. The accelerated aging protocol significantly increased the S of Filtek P60 and Filtek Silorane, whereas storage in the oven significantly decreased the S for all of the composites tested. Filtek P60 was the only composite not affected by the lower storage temperatures tested for S, whereas for the silorane this parameter was impacted at the same conditions. The factor "dose" was not statistically significant. Conclusions: The syringe storage at different temperature conditions proved to influence mostly the flexural strength, a clinically important characteristic considering the posterior indication of the materials tested. The silorane composite should not be stored at lower temperatures.

  17. Syringe-Injectable Electronics with a Plug-and-Play Input/Output Interface.

    Science.gov (United States)

    Schuhmann, Thomas G; Yao, Jun; Hong, Guosong; Fu, Tian-Ming; Lieber, Charles M

    2017-09-13

    Syringe-injectable mesh electronics represent a new paradigm for brain science and neural prosthetics by virtue of the stable seamless integration of the electronics with neural tissues, a consequence of the macroporous mesh electronics structure with all size features similar to or less than individual neurons and tissue-like flexibility. These same properties, however, make input/output (I/O) connection to measurement electronics challenging, and work to-date has required methods that could be difficult to implement by the life sciences community. Here we present a new syringe-injectable mesh electronics design with plug-and-play I/O interfacing that is rapid, scalable, and user-friendly to nonexperts. The basic design tapers the ultraflexible mesh electronics to a narrow stem that routes all of the device/electrode interconnects to I/O pads that are inserted into a standard zero insertion force (ZIF) connector. Studies show that the entire plug-and-play mesh electronics can be delivered through capillary needles with precise targeting using microliter-scale injection volumes similar to the standard mesh electronics design. Electrical characterization of mesh electronics containing platinum (Pt) electrodes and silicon (Si) nanowire field-effect transistors (NW-FETs) demonstrates the ability to interface arbitrary devices with a contact resistance of only 3 Ω. Finally, in vivo injection into mice required only minutes for I/O connection and yielded expected local field potential (LFP) recordings from a compact head-stage compatible with chronic studies. Our results substantially lower barriers for use by new investigators and open the door for increasingly sophisticated and multifunctional mesh electronics designs for both basic and translational studies.

  18. A syringe-like love dart injects male accessory gland products in a tropical hermaphrodite.

    Directory of Open Access Journals (Sweden)

    Joris M Koene

    Full Text Available Sexual conflict shapes the evolution of many behaviours and processes involved in reproduction. Nearly all evidence supporting this comes from species where the sexes are separated. However, a substantial proportion of animals and most plants are hermaphroditic, and theoretical work predicts that sexual conflict plays an important role even when the sexes are joined within one individual. This seems to have resulted in bizarre mating systems, sophisticated sperm packaging and complex reproductive morphologies. By far the best-known example of such a strategy in hermaphrodites is the shooting of so-called love-darts in land snails. All known love darts carry a gland product on their outside and enter this into the partner's hemolymph by stabbing. Here, we show that species of the snail genus Everettia possess a syringe-like dart that serves as a real injection needle. Their dart is round in cross-section, contains numerous channels, and has perforations along its side. Histology and electron microscopy show that these holes connect to the channels inside the dart and run all the way up to the elaborate mucus glands that are attached to the dart sac. This is the first report on a love dart that is used as a syringe to directly inject the gland product into the partner's hemolymph. Although the exact use and function of this dart remains to be demonstrated, this clearly adds to the complexity of the evolution of reproductive strategies in hermaphrodites in general. Moreover, the perforations on the outside of the love dart resemble features of other injection devices, thus uncovering common design and repeated evolution of such features in animals.

  19. A syringe-like love dart injects male accessory gland products in a tropical hermaphrodite.

    Science.gov (United States)

    Koene, Joris M; Liew, Thor-Seng; Montagne-Wajer, Kora; Schilthuizen, Menno

    2013-01-01

    Sexual conflict shapes the evolution of many behaviours and processes involved in reproduction. Nearly all evidence supporting this comes from species where the sexes are separated. However, a substantial proportion of animals and most plants are hermaphroditic, and theoretical work predicts that sexual conflict plays an important role even when the sexes are joined within one individual. This seems to have resulted in bizarre mating systems, sophisticated sperm packaging and complex reproductive morphologies. By far the best-known example of such a strategy in hermaphrodites is the shooting of so-called love-darts in land snails. All known love darts carry a gland product on their outside and enter this into the partner's hemolymph by stabbing. Here, we show that species of the snail genus Everettia possess a syringe-like dart that serves as a real injection needle. Their dart is round in cross-section, contains numerous channels, and has perforations along its side. Histology and electron microscopy show that these holes connect to the channels inside the dart and run all the way up to the elaborate mucus glands that are attached to the dart sac. This is the first report on a love dart that is used as a syringe to directly inject the gland product into the partner's hemolymph. Although the exact use and function of this dart remains to be demonstrated, this clearly adds to the complexity of the evolution of reproductive strategies in hermaphrodites in general. Moreover, the perforations on the outside of the love dart resemble features of other injection devices, thus uncovering common design and repeated evolution of such features in animals.

  20. Three-dimensional Quantitative Porosity Characterization of Syringe- versus Hand-mixed Set Epoxy Resin Root Canal Sealer.

    Science.gov (United States)

    De-Deus, Gustavo; Scelza, Miriam Z; Neelakantan, Prasanna; Sharma, Subash; Neves, Aline de Almeida; Silva, Emmanuel João Nogueira Leal

    2015-01-01

    The aim of the present study was to compare the porosity characteristics of AH Plus Jet(tm) syringe-mix and the conventional hand-mixed AH Plus root canal sealers by three-dimensional quantitative high-resolution micro-computed tomography (micro-CT). Seven test specimens were prepared from each tested sealer by a single operator following the manufacturer's instructions and poured into pre-lubricated plastic split-ring moulds. Set sealer test specimens were scanned using a micro-CT device and the shadow images were reconstructed into cross-sectional slices. The evaluated parameters were (i) total pore count, (ii) total pore volume and mean pore volume, (iii) total porosity (% of pore volume in relation to total sealer volume) and (iv) mean pore distance to the sealer lateral external surface. In both groups, most pores were localized within the external sealer perimeter (0.05 mm from the external surface). Hand-mixed AH Plus specimens showed statistically significant higher mean total pore count, total pore volume and total porosity (p=0.001) than the syringe-mixed specimens. However, mean pore sizes in AH Plus syringe-mixed specimens were significantly higher (p=0.046) than the AH Plus hand-mixed counterparts. Hand-mixed AH Plus was associated with higher total mean pore count, volume and total porosity compared to syringe mixed AH Plus.

  1. A computer-controlled syringe driver for use during anaesthesia. A modification of the Graseby MS16A.

    Science.gov (United States)

    Cohen, A T

    1986-06-01

    The requirements of a drug infusion device for use in theatre are discussed. A modification of the Graseby MS16A syringe pump and an interface circuit permitting its remote control by microcomputer are described. The pump is controlled via a standard computer interface (RS232) which makes it a unique and powerful research tool. Aspects of safety are considered.

  2. Study of male sterility in Taiwania cryptomerioides Hayata (Taxodiaceae).

    Science.gov (United States)

    Chen, S-H; Chung, N-J; Wang, Y-N; Lee, C-L; Lee, Y-L; Tsai, P-F

    2006-08-01

    A study of male sterility over a period of three consecutive years on a conifer species endemic to Taiwan, Taiwania cryptomerioides Hayata (Taxodiaceae), was done for this article. With the aids of fluorescence and electron microscopic observations, the ontogenic processes in the fertile and sterile microsporangia are compared, using samples collected from Chitou Experimental Forest and Yeou-Shoei-Keng Clonal Orchard of the National Taiwan University, Nantou, Taiwan. The development of male strobili occurred from August to the end of March. Microsporogenesis starts with the formation of the archesporium and ends with the maturation of 2-celled pollen grains within the dehiscing microsporangium. Before meiosis, there was no significant difference in ultrastructure between the fertile and sterile microsporangia. Asynchronous pollen development with various tetrad forms may occur in the same microsporangium of either fertile or sterile strobili. However, a callose wall was observable in the fertile dyad and tetrad, but not in the sterile one. After dissolution of the callose wall, the fertile microspores were released into the locule, while some sterile microspores still retained as tetrads or dyads with intertwining of exine walls in the proximal faces. As a result, there was no well developed lamellated endexine and no granulate ectexine or intine in the sterile microspores. Eventually, the intracellular structures in sterile microspores were dramatically collapsed before anthesis. The present study shows that the abortion in pollen development is possibly attributed to the absence of the callose wall. The importance of this structure to the male sterility of T. cryptomerioides is discussed.

  3. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  4. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  5. Eugenics, sterilization, and historical memory in the United States.

    Science.gov (United States)

    Stern, Alexandra Minna

    2016-12-01

    From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and "suffering from a mental affliction likely to be inherited." Working with a unique resource - a dataset created from 19,000 sterilization recommendations - my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  6. System and method of applying energetic ions for sterilization

    Science.gov (United States)

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and across the cold plasma, is provided.

  7. ACOG Practice bulletin no. 133: benefits and risks of sterilization.

    Science.gov (United States)

    2013-02-01

    Female and male sterilization are both safe and effective methods of permanent contraception used by more than 220 million couples worldwide . Approximately 600,000 tubal occlusions and 200,000 vasectomies are performed in the United States annually . For women seeking permanent contraception, sterilization obviates the need for user-dependent contraception throughout their reproductive years and provides an excellent alternative for those with medical contraindications to reversible methods. The purpose of this document is to review the evidence for the safety and effectiveness of female sterilization in comparison with male sterilization and other forms of contraception.

  8. Sterile neutrino searches via displaced vertices at LHCb

    Science.gov (United States)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2017-11-01

    We explore the sensitivity of displaced vertex searches at LHCb for testing sterile neutrino extensions of the Standard Model towards explaining the observed neutrino masses. We derive estimates for the constraints on sterile neutrino parameters from a recently published displaced vertex search at LHCb based on run 1 data. They yield the currently most stringent limit on active-sterile neutrino mixing in the sterile neutrino mass range between 4.5 GeV and 10 GeV. Furthermore, we present forecasts for the sensitivities that could be obtained from the run 2 data and also for the high-luminosity phase of the LHC.

  9. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  10. Contact with hospital syringes containing body fluids: implications for medical waste management regulation Jeringas en contacto con sangre y fluidos corporales utilizadas en el hospital: implicaciones para el manejo de desechos hospitalarios

    OpenAIRE

    Patricia Volkow; Bénédicte Jacquemin; Diana Vilar-Compte; José Ramón Castillo

    2003-01-01

    OBJECTIVE: To determine amount of syringes used in the hospital and extent of contact with blood and body fluids of these syringes. MATERIAL AND METHODS: Syringe use was surveyed at a tertiary care center for one week; syringes were classified into the following four categories according to use: a) contained blood; b) contained other body fluids (urine, gastric secretion, cerebrospinal fluid, wound drainage); c) used exclusively for drug dilution and application in plastic intravenous (IV) tu...

  11. Sterilization of biological tissues with ionizing radiation

    International Nuclear Information System (INIS)

    Reyes F, M.L.; Martinez P, M.E.; Luna Z, D.

    1997-01-01

    On June 1994, the National Institute of Nuclear Research (ININ) and the South Central Hospital for High Specialty of PEMEX (HCSAE) began a joint work with the finality to obtain radio sterilized amniotic membranes for to be used as cover (biological bandage) in burnt patients. Subsequently the Chemistry Faculty of UNAM and the National Institute of Cardiology began to collaborate this last with interest on cardiac valves for graft. Starting from 1997, the International Atomic Energy Agency (IAEA) supports this project (MEX/7/008) whose main objective is to set up the basis to establish in Mexico a Radio sterilized Tissue Bank (amniotic membranes, skin, bones, tendons, cardiac valves, etc.) to be used with therapeutic purposes (grafts). The IAEA support has consisted in the equipment acquisition which is fundamental for the Tissue Bank performance such as an experimental irradiator, laminar flow bell, lyophilizer, vacuum sealer and special knives for tissues. Also visits to Mexico of experts have been authorized with the aim of advising to the personnel which participate in the project and scientific visits of this personnel to another tissue banks (Sri Lanka and Argentine). The establishment in Mexico of a Tissue bank will be a great benefit because it will have availability of distinct tissues for grafts and it will reduce the synthetic materials importation which is very expensive. (Author)

  12. Sterile Neuroinflammation and Strategies for Therapeutic Intervention

    Directory of Open Access Journals (Sweden)

    Manoj Banjara

    2017-01-01

    Full Text Available Sterile neuroinflammation is essential for the proper brain development and tissue repair. However, uncontrolled neuroinflammation plays a major role in the pathogenesis of various disease processes. The endogenous intracellular molecules so called damage-associated molecular patterns or alarmins or damage signals that are released by activated or necrotic cells are thought to play a crucial role in initiating an immune response. Sterile inflammatory response that occurs in Alzheimer’s disease (AD, Parkinson’s disease (PD, stroke, hemorrhage, epilepsy, or traumatic brain injury (TBI creates a vicious cycle of unrestrained inflammation, driving progressive neurodegeneration. Neuroinflammation is a key mechanism in the progression (e.g., AD and PD or secondary injury development (e.g., stroke, hemorrhage, stress, and TBI of multiple brain conditions. Hence, it provides an opportunity for the therapeutic intervention to prevent progressive tissue damage and loss of function. The key for developing anti-neuroinflammatory treatment is to minimize the detrimental and neurotoxic effects of inflammation while promoting the beneficial and neurotropic effects, thereby creating ideal conditions for regeneration and repair. This review outlines how inflammation is involved in the pathogenesis of major nonpathogenic neuroinflammatory conditions and discusses the complex response of glial cells to damage signals. In addition, emerging experimental anti-neuroinflammatory drug treatment strategies are discussed.

  13. Towards sustainable design for single-use medical devices.

    Science.gov (United States)

    Hanson, Jacob J; Hitchcock, Robert W

    2009-01-01

    Despite their sophistication and value, single-use medical devices have become commodity items in the developed world. Cheap raw materials along with large scale manufacturing and distribution processes have combined to make many medical devices more expensive to resterilize, package and restock than to simply discard. This practice is not sustainable or scalable on a global basis. As the petrochemicals that provide raw materials become more expensive and the global reach of these devices continues into rapidly developing economies, there is a need for device designs that take into account the total life-cycle of these products, minimize the amount of non-renewable materials consumed and consider alternative hybrid reusable / disposable approaches. In this paper, we describe a methodology to perform life cycle and functional analyses to create additional design requirements for medical devices. These types of sustainable approaches can move the medical device industry even closer to the "triple bottom line"--people, planet, profit.

  14. Antiophidian sera sterility control: topics in perspective

    Directory of Open Access Journals (Sweden)

    Paula Gomes Santos

    2009-09-01

    Full Text Available The aim of this work is to review the most important topics about the antiophidic sera sterility, including obtaining methods, sterilization procedures and clean room control using Vital Brazil Institute (VBI as an example. Bibliographical research was performed through Medline, Lilacs, PubMed, ISI and the Fundação Oswaldo Cruz - RJ and VBI Libraries, from 1960 to 2009. The antiophidic sera for human use are immunobiologic products produced in Brazil by three national laboratories, including VBI. Due to the parenteral use, these products should be sterile and pyrogen-free, which demands the microbiological control during the whole fabrication process. The sterility and pyrogen tests are important steps to ensure the quality and safety of these immunobiological products. Thus, these tests are target for continue evaluation and improvement. The most interfering aspects in the consistency and analytical patterns include the proper method selection, sampling, culture conditions and validation criteria. As the national and international legal requirements are cautious with the assays validation and approval of sterile parenteral products; the intrinsic limitations for established assays still require more investigation aiming the continue improvement of the microorganism and contaminants detection methods and optimization of the analysis extent.O objetivo deste trabalho é revisar os tópicos mais relevantes para o controle da esterilidade de soros antiofídicos, abordando-se métodos de obtenção, procedimentos de esterilização e o controle de áreas limpas utilizando como exemplo os procedimentos adotados pelo Instituto Vital Brazil (IVB. Um levantamento bibliográfico foi realizado no Medline, ISI, Biblioteca da Fundação Oswaldo Cruz-RJ e IVB, no período de 1960 a 2009. Os soros antiofídicos para uso humano são produtos imunobiológicos fabricados no Brasil por três laboratórios nacionais, dentre eles o IVB. Por serem de administra

  15. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  16. Fertility and reproductive history of sterilized and non-sterilized women in Campinas, São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Maria José Duarte Osis

    Full Text Available This article compares sterilized and non-sterilized women in relation to socio-demographic characteristics, reproductive history, and cohabitation status. Women from 30 to 49 years of age and residing in Campinas, São Paulo State, Brazil, were interviewed with a pre-tested and structured questionnaire: 236 women sterilized at least five years before the interview and 236 non-sterilized women. The sterilized women were significantly more likely to be married or cohabiting, to be younger when they began cohabiting, and to have been in the union longer than the non-sterilized women. They also began childbearing at an earlier age and had a history of more pregnancies and more live births than non-sterilized women. Factors associated with a history of 3 or more live births at the time of the interview were surgical sterilization, younger age at first childbirth, older age at the interview, recognition of fewer contraceptive methods, and lower per capita income. The article concludes that sterilization generally appears to be the consequence of higher fertility in a group of women who initiate childbearing early in life, although its role in preventing these women from having even larger families may also have a demographic impact.

  17. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  18. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Krishnan, Vijaya

    2004-01-01

    Full Text Available EnglishPrior to early 1970s, traditional methods were the principal means ofcontrolling the number and spacing of births. Today, an estimated 57 per cent of the world's marriedwomen use contraceptives and half use modern methods such as medical sterilizations. Recent statisticssuggest that Canada has the highest sterilization rate in the Western world. This paper presentsfindings of research examining sterilization trends in Canada with respect to changing patterns in theuse of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligationand an increase in the use of hysterectomy over the period 1984-1995. Less educated women are morelikely to be in the forefront of modern methdos of contraception.FrenchAvant les années 1970, les méthodes traditionnelles représentaient le principalmoyen de contrôler et d’espacer le nombre de naissances. De nos jours, onestime que 57 pour cent des femmes mariées dans le monde entier utilisent unmoyen contraceptif et la moitié utilise des méthodes modernes telles que lastérilisation. Les dernières statistiques indiquent que le Canada compte le tauxde stérilisations le plus élevé dans le monde occidental. Cet article présente lesconclusions de recherches portant sur les tendances en matière de stérilisation auCanada en ce qui concerne les modèles changeants d’utilisation de moyens decontraception modernes et ce, à partir de données de l’Enquête canadienne sur lafécondité de 1984 et de l’Enquête sociale générale (ESG de 1995. La principaleconclusion qui en est ressortie est une réduction de la ligature des trompes etune augmentation du nombre d’hystérectomies de 1984 à 1995. Les femmesmoins éduquées sont plus portées à se trouver au premier plan des méthodes decontraception modernes.

  19. History of the sterile insect technique

    International Nuclear Information System (INIS)

    Klassen, W.; Curtis, C.F.

    2005-01-01

    During the 1930s and 1940s the idea of releasing insects of pest species to introduce sterility (sterile insect technique or SIT) into wild populations, and thus control them, was independently conceived in three extremely diverse intellectual environments. The key researchers were A. S. Serebrovskii at Moscow State University, F. L. Vanderplank at a tsetse field research station in rural Tanganyika (now Tanzania), and E. F. Knipling of the United States Department of Agriculture. Serebrovskii's work on chromosomal translocations for pest population suppression could not succeed in the catastrophic conditions in the USSR during World War II, after which he died. Vanderplank used hybrid sterility to suppress a tsetse population in a large field experiment, but lacked the resources to develop this method further. Knipling and his team exploited H. J. Muller's discovery that ionizing radiation can induce dominant lethal mutations, and after World War II this approach was applied on an area-wide basis to eradicate the New World screwworm Cochliomyia hominivorax (Coquerel) in the USA, Mexico, and Central America. Since then very effective programmes integrating the SIT have been mounted against tropical fruit flies, some species of tsetse flies Glossina spp., the pink bollworm Pectinophora gossypiella (Saunders), and the codling moth Cydia pomonella (L.). In non-isolated onion fields in the Netherlands, the onion maggot Delia antiqua (Meigen) has since 1981 been suppressed by the SIT. In the 1970s there was much research conducted on mosquito SIT, which then went into 'eclipse', but now appears to be reviving. Development of the SIT for use against the boll weevil Anthonomus grandis grandis Boheman and the gypsy moth Lymantria dispar (L.) has ended, but it is in progress for two sweetpotato weevil species, Cylas formicarius (F.) and Euscepes postfasciatus (Fairmaire), the false codling moth Cryptophlebia leucotreta (Meyrick), the carob moth Ectomyelois ceratoniae

  20. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  1. Assessing genetic variability in male sterile and low fertile citrus ...

    African Journals Online (AJOL)

    Understanding phylogenetic relationships and genetic diversity in citrus are important in clarifying genetic relationships, characterizing germplasm and the registration of new cultivars. In this study, the genetic diversity of 28 accessions of citrus including male sterile, sterile, low fertile and fertile cultivars were investigated ...

  2. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  3. Tracking the expression of photosensitive genic male sterility genes ...

    African Journals Online (AJOL)

    Photoperiod sensitive genic male sterile rice lines contain genes that induce complete sterility in high temperature and long day light length period, and revert to fertility in optimum low temperature and short day light length period. These lines are good candidates for hybrid rice seed production. The main challenge limiting ...

  4. An alternative safer and cost effective surface sterilization method for ...

    African Journals Online (AJOL)

    Regardless of its serious health effect, mercury chloride is frequently utilized for surface sterilization to mitigate microbial contamination in sugarcane tissue culture. The current study aimed at finding an alternative safer and cost effective sterilization method to substitute mercury chloride. In the study, sugarcane shoot tip ...

  5. Effect of sterilization on mineralization of straw and black carbon

    DEFF Research Database (Denmark)

    Bobul'ská, Lenka; Bruun, Sander; Fazekašová, Danica

    2013-01-01

    The study was aimed at investigating the role of microorganisms in the degradation of BC (black carbon). CO evolution was measured under sterilized and non-sterilized soil using BC and straw amendments. Black carbon and straw were produced from homogenously C labelled roots of barley (Hordeum vul...... abiotic source must also be present perhaps abiotic mineralization of labile BC components....

  6. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  7. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  8. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  9. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...... by Elsevier Inc. All rights reserved....

  10. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  11. Female sterilization by tubal ligation at caesarean section in Makurdi ...

    African Journals Online (AJOL)

    Background: Female sterilization is an important tool in reducing unplanned pregnancy and maternal mortality in our environment. The aim of this study was to determine the incidence, sociodemographic characteristics, technique, effectiveness and complications associated with female sterilization by bilateral tubal ligation ...

  12. Puzzles in modern biology. I. Male sterility, failure reveals design.

    Science.gov (United States)

    Frank, Steven A

    2016-01-01

    Many human males produce dysfunctional sperm. Various plants frequently abort pollen. Hybrid matings often produce sterile males. Widespread male sterility is puzzling. Natural selection prunes reproductive failure. Puzzling failure implies something that we do not understand about how organisms are designed. Solving the puzzle reveals the hidden processes of design.

  13. Thermalisation of light sterile neutrinos in the early universe

    DEFF Research Database (Denmark)

    Hannestad, Steen; Tamborra, Irene; Tram, Thomas

    2012-01-01

    on the current cosmological data have been derived using simplified assumptions about thermalisation of the sterile neutrino at the Big Bang Nucleosynthesis (BBN) epoch. These assumptions are not necessarily justified and here we solve the full quantum kinetic equations in the (1 active + 1 sterile) scenario...

  14. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  15. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  16. Sterilization by Minilaparotomy in South-Eastern Nigeria | Nwogu ...

    African Journals Online (AJOL)

    The study aimed to assess the trend in acceptance and characteristics of acceptors of female sterilization between January 1999 and December 2006 at the University of Nigeria Teaching Hospital, Enugu, South-Eastern Nigeria. There were a total of 20,485 new clients, with 212 (1.0%) accepting sterilization between ...

  17. 7 CFR 305.28 - Kiln sterilization treatment schedule.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Kiln sterilization treatment schedule. 305.28 Section 305.28 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH... sterilization treatment schedule. T404-b-4 Dry bulb temperature( °F) Wet bulb depression( °F) Percent...

  18. Sterilization of the Mentally Ill and the Mentally Retarded.

    Science.gov (United States)

    National Association of State Mental Health Program Directors, Washington, DC.

    Reported were the results of a survey on the sterilization of the mentally ill and the mentally retarded. Thirty-three states responded to the survey. It was found that 17 states have a sterilization statute, but the existence of the statute was explained not to mean that the procedure was used. Sixteen states responded that they did not have a…

  19. An alternative safer and cost effective surface sterilization method for ...

    African Journals Online (AJOL)

    user

    2013-10-30

    Oct 30, 2013 ... Regardless of its serious health effect, mercury chloride is frequently utilized for surface sterilization to mitigate microbial contamination in sugarcane tissue culture. The current study aimed at finding an alternative safer and cost effective sterilization method to substitute mercury chloride. In the study,.

  20. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    Science.gov (United States)

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  1. Radiation effects on polypropylene for sterilization.

    Science.gov (United States)

    Khang, G; Lee, H B; Park, J B

    1996-01-01

    In order to improve the resistance of gamma-radiation sterilization of polypropylene (PP), the formulations of the additives such as antioxidants, crosslinking agent, and trans-stilbene oxide (StO) have been carried out. The irradiated PP and ethylene-propylene copolymer samples with control and additives were characterized by mechanical tester, colorimetry, and Fourier transform infrared spectroscopy with total attenuated reflectance mode (FTIR-ATR). Crosslinking agent and StO formulated PP showed remarkable radiation resistance and minimum discoloration. Also, radiation resistance of ethylene-propylene copolymers with 3% of ethylene contents was better than that of PP homopolymers in the case of no additives. The proposed mechanisms of radiation stabilization with additives are also discussed.

  2. Sterile neutrinos and B–L symmetry

    Directory of Open Access Journals (Sweden)

    Pavel Fileviez Pérez

    2018-02-01

    Full Text Available We revisit the relation between the neutrino masses and the spontaneous breaking of the B–L gauge symmetry. We discuss the main scenarios for Dirac and Majorana neutrinos and point out two simple mechanisms for neutrino masses. In this context the neutrino masses can be generated either at tree level or at quantum level and one predicts the existence of very light sterile neutrinos with masses below the eV scale. The predictions for lepton number violating processes such as μ→e and μ→eγ are discussed in detail. The impact from the cosmological constraints on the effective number of relativistic degree of freedom is investigated.

  3. [The psychosocial background of sterile patients].

    Science.gov (United States)

    Pusch, H H; Urdl, W; Walcher, W

    1989-01-01

    The psychosocial background of 300 childless couples from the Infertility Clinic of the Department of Gynecology and Obstetrics, University of Graz, was evaluated by means of a questionnaire and statistical analysis of data from their files. Points of special interest were problems such as interactions of the couple, motivations for the desire of children, psychosomatics, andrological investigation within the gynecological department, sexual habits and motivation and compliance concerning investigations and treatment. 72% of the questionnaires were returned. 50% of the sterile couples preferred to attend the infertility clinic together. 26% felt restrictions in their sexual behaviour due to the unrealized desire of children, 48% expected improvements in their partnership if they could have children. Compliance of male partners concerning the regular intake of prescribed medicaments was 83%, 63% accepted to stop smoking in cases of pathospermia.

  4. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  5. Heavy Sterile Neutrino in Dark Matter Searches

    Directory of Open Access Journals (Sweden)

    Paraskevi C. Divari

    2018-01-01

    Full Text Available Sterile neutrinos are possible dark matter candidates. We examine here possible detection mechanisms, assuming that the neutrino has a mass of about 50 keV and couples to the ordinary neutrino. Even though this neutrino is quite heavy, it is nonrelativistic with a maximum kinetic energy of 0.1 eV. Thus new experimental techniques are required for its detection. We estimate the expected event rate in the following cases: (i measuring electron recoil in the case of materials with very low electron binding; (ii low temperature crystal bolometers; (iii spin induced atomic excitations at very low temperatures, leading to a characteristic photon spectrum; (iv observation of resonances in antineutrino absorption by a nucleus undergoing electron capture; (v neutrino induced electron events beyond the end point energy of beta decaying systems, for example, in the tritium decay studied by KATRIN.

  6. Radiation treatment for sterilization of packaging materials

    International Nuclear Information System (INIS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-01-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology

  7. Radiation sterilized bone response to dynamic loading

    Energy Technology Data Exchange (ETDEWEB)

    Mardas, Marcin, E-mail: marcin.mardas@skpp.edu.pl [Department of Oncology, Poznan University of Medical Sciences, ul. Szamarzewskiego 82/84, 60-569 Poznan (Poland); Kubisz, Leszek [Department of Biophysics, Poznan University of Medical Sciences, ul. Fredry 10, 61-701 Poznan (Poland); Biskupski, Piotr; Mielcarek, Slawomir [Department of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Poznan (Poland); Stelmach-Mardas, Marta [Department of Bromatology, Poznan University of Medical Sciences, ul. Marcelinska 420, 60-354 Poznan (Poland); Kaluska, Iwona [Centre for Radiation Research and Technology, Institute of Nuclear Chemistry and Technology, ul. Dorodna 16, 03-195 Warsaw (Poland)

    2012-08-01

    Allogeneic bone grafts are used on a large scale in surgeries. To avoid the risk of infectious diseases, allografts should be radiation-sterilized. So far, no international consensus has been achieved regarding the optimal radiation dose. Many authors suggest that bone sterilization deteriorates bone mechanical properties. However, no data on the influence of ionizing radiation on bone dynamic mechanical properties are available. Bovine femurs from 2-year old animal were machine cut and irradiated with the doses 10, 15, 25, 35, 45 and 50 kGy. Dynamic mechanical analysis was performed at 1-10 Hz at the temperature range of 0-350 Degree-Sign C in 3-point bending configuration. No statistically significant differences in storage modulus were observed. However, there were significant decreased values of loss modulus between the samples irradiated with doses of 10 ({down_arrow}14.3%), 15, 45 and 50 kGy ({down_arrow}33.2%) and controls. It was stated that increased irradiation dose decreases the temperature where collagen denaturation process starts and increases the temperature where the collagen denaturation process finishes. It was shown that activation energy of denaturation process is significantly higher for the samples irradiated with the dose of 50 kGy (615 kJ/mol) in comparison with control samples and irradiation with other doses (100-135 kJ/mol). - Highlights: Black-Right-Pointing-Pointer We examine changes in the storage modulus and loss modulus of samples irradiated with doses of 10-50 kGy. Black-Right-Pointing-Pointer We examine changes in the denaturation temperature of samples irradiated with doses of 10-50 kGy. Black-Right-Pointing-Pointer We examine changes in the activation energy of denaturation process of samples irradiated with doses of 10-50 kGy.

  8. Mechanisms of urinary tract sterility maintenance

    Directory of Open Access Journals (Sweden)

    Emilia Okrągła

    2014-06-01

    Full Text Available Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system’s action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI are women (an additional risk factor is pregnancy, but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS, fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  9. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  10. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  11. Development of ozone sterilization system based microcontroller for E. Coli bacteria sterilization

    Science.gov (United States)

    Eko Fahrudin, Arfan; Endarko; Vijai Nasrulloh, Amar; Sari, Nurma

    2017-05-01

    It has been created microcontroller-based ozone sterilization system which is used for E. Coli bacteria sterilization. The created system consists of a neon sign transformer, corona electrode, ozone gas chamber container and ozone gas metering systems. Neon sign transformer and corona electrode are then assembled into an ozone generator that works on the principle of corona discharge. The use of ozone generators is controlled by microcontroller system. Ozone gas is produced by ozone generators which housed in a chamber and equipped by ozone gas indicator. The results of ozone gas effect testing in E. Coli with varied exposure of 15, 30 and 45 minutes showed the decrease number of E. Coli colonies of tested bacteria samples compared to the control sample without ozone gas exposure.

  12. AN AUDIT OF WHETHER PRESCRIBED DOSES ARE MEASURABLE ON THE GRADUATIONS OF ONE ORAL SYRINGE.

    Science.gov (United States)

    Balsara, Jigna; Fletcher, Penny

    2016-09-01

    In paediatrics drugs are prescribed as mg/kg doses to facilitate accurate dosing. Anecdotally, some drugs are prescribed in such a way that the volume to be given is difficult to measure which may lead to inaccuracies and potential for error. Locally, errors have been reported where there has been a misunderstanding of the required dose, especially when decimal points are involved. This audit aimed to evaluate doses prescribed for in-patient children and evaluate whether they can be measured using the printed markings of one oral syringe. Data were collected for paediatric in-patients between 16th February and 27th March 2015 from paper drug charts and an electronic prescribing system depending which was in use in each area. Specific data on patient age, weight and prescribed dose were collected. Volumes were then calculated using the enteral products kept in the Trust formulary, including unlicensed specials. The prescribed volumes were reviewed against the Medicina Home® enteral syringes to see if they were measurable on the printed graduations of one oral syringe (in line with local dispensing standards). If they could not be measured, the percentage dose rounding required was calculated to see if doses could be rounded. A judgement was then made as to whether this was within an acceptable safe dose limit. Data for 560 individual medication orders for oral medicine were collected, 257 from electronic prescribing and 303 from paper charts. Of these 457 were liquid doses, 103 were from products only available as tablets or capsules. Of the 257 electronically prescribed doses, 61 (24%) were not measurable. Of the 303 paper chart doses, 57 (19%) were not measurable.Of the 457 liquid doses 77 only needed up to 4% dose adjustment to become measurable. A further 10 doses required up to 9% dose adjustment.Drugs that were frequently prescribed as non-measurable doses were: diazepam, alimemazine, chloral hydrate, azithromycin, metronidazole, paracetamol & ibuprofen

  13. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  14. A two-stage procedure for determining unsaturated hydraulic characteristics using a syringe pump and outflow observations

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Jensen, Karsten Høgh; Hollenbeck, Karl-Josef

    1997-01-01

    A fast two-stage methodology for determining unsaturated flow characteristics is presented. The procedure builds on direct measurement of the retention characteristic using a syringe pump technique, combined with inverse estimation of the hydraulic conductivity characteristic based on one......-step outflow experiments. The direct measurements are obtained with a commercial syringe pump, which continuously withdraws fluid from a soil sample at a very low and accurate how rate, thus providing the water content in the soil sample. The retention curve is then established by simultaneously monitoring......-step outflow data and the independently measured retention data are included in the objective function of a traditional least-squares minimization routine, providing unique estimates of the unsaturated hydraulic characteristics by means of numerical inversion of Richards equation. As opposed to what is often...

  15. Technical communication: design and in vitro testing of a pressure-sensing syringe for endotracheal tube cuffs.

    Science.gov (United States)

    Slocum, Alexander H; Slocum, Alexander H; Spiegel, Joan E

    2012-05-01

    Endotracheal intubation is a frequently performed procedure in the prehospital setting, intensive care unit, and for patients undergoing surgery. The endotracheal tube cuff must be inflated to a pressure that prevents air leaks without compromising tracheal mucosal blood flow. For simultaneous endotracheal tube cuff inflation and measurement, we designed and tested a novel pressure-sensing syringe in vitro. The prototype was developed using a standard 10-mL polycarbonate syringe body that houses a plunger and a silicone rubber bellows, the pressure-sensing element. Bellow feasibility was determined and modeled using finite element analysis. Repeatability testing at each pressure measurement for each bellows (pressure versus deflection) was within an average standard deviation of 0.3 cm to 1.61 cm (1%-5% error). Using an aneroid manometer for comparison, there was excellent linear correlation with a Spearman rank of 0.99 (P < 0.001), up to 30 cm H(2)O.

  16. Prospective clinical evaluation of a new manometer syringe that distinguishes pressures below 30 and above 50 mmHg.

    Science.gov (United States)

    Schummer, Wolfram; Schummer, Claudia

    2008-09-01

    To evaluate a new disposable syringe (Certofix PresSure Check [B Braun Melsungen AG, Melsungen, Germany]) that serves as a manometer. Prospective study. University hospital's cardiac surgery suite. 21 consecutive patients with continuous invasive monitoring of central venous and arterial pressures during cardiothoracic surgery. The Certofix PresSure Check syringe was connected to the side port of the central venous and arterial catheters. Central venous pressures were correctly indicated as below 30 mmHg and arterial pressures as above 50 mmHg in all 21 patients. Certofix PresSure Check provides a unique way of testing whether a catheter is placed in a low or high pressure system. It can be used for identifying inadvertent arterial punctures.

  17. An investigation into the stability and sterility of citric acid solutions used for cough reflex testing.

    Science.gov (United States)

    Falconer, James R; Wu, Zimei; Lau, Hugo; Suen, Joanna; Wang, Lucy; Pottinger, Sarah; Lee, Elaine; Alazawi, Nawar; Kallesen, Molly; Gargiulo, Derryn A; Swift, Simon; Svirskis, Darren

    2014-10-01

    Citric acid is used in cough reflex testing in clinical and research settings to assess reflexive cough in patients at risk of swallowing disorders. To address a lack of knowledge in this area, this study investigated the stability and sterility of citric acid solutions. Triplicate solutions of citric acid (0.8 M) in isotonic saline were stored at 4 ± 2 °C for up to 28 days and analysed by high-performance liquid chromatography. Microbiological sterility of freshly prepared samples and bulk samples previously used for 2 weeks within the hospital was determined using a pour plate technique. Microbial survival in citric acid was determined by inoculating Staphylococcus aureus, Escherichia coli, or Candida albicans into citric acid solution and monitoring the number of colony-forming units/mL over 40 min. Citric acid solutions remained stable at 4 °C for 28 days (98.4 ± 1.8 % remained). The freshly prepared and clinical samples tested were sterile. However, viability studies revealed that citric acid solution allows for the survival of C. albicans but not for S. aureus or E. coli. The microbial survival study showed that citric acid kills S. aureus and E. coli but has no marked effect on C. albicans after 40 min. Citric acid samples at 0.8 M remained stable over the 4-week testing period, with viable microbial cells absent from samples tested. However, C. albicans has the ability to survive in citric acid solution if inadvertently introduced in practice. For this reason, in clinical and research practice it is suggested to use single-use aliquots prepared aseptically which can be stored for up to 28 days at 4 °C.

  18. A portable multi-syringe flow system for spectrofluorimetric determination of iodide in seawater.

    Science.gov (United States)

    Frizzarin, Rejane M; Aguado, Enrique; Portugal, Lindomar A; Moreno, Daniel; Estela, José M; Rocha, Fábio R P; Cerdà, Victor

    2015-11-01

    A miniaturized analyzer encompassing a poly(methyl methacrylate) chip with integrated spectrofluorimetric detection and solutions propelling by a multi-syringe module is proposed. Iodide was determined through its catalytic effect on the reaction between Ce(IV) and As(III). Matrix isopotential synchronous fluorescence was explored to set the excitation and emission wavelengths. A two-level full factorial design allowed to evaluate the significance of variables (Ce(IV), As(III) and H2SO4 concentrations) and their interaction effects in the experimental domain. A Doehlert Matrix was applied to identify the critical values. The optimized procedure showed a linear response from 1 to 100 μg L(-1) (S=53.7+2.61C, in which S is the net fluorescence and C is iodide concentration in μg L(-1)). Detection limit, coefficient of variation (n=6) and sampling rate were estimated at 0.3 μg L(-1), 0.8% and 20 h(-1), respectively. Recoveries within 90-117% were estimated for iodide spiked to seawater samples. The proposed procedure stands out because of the portability, robustness, and simplicity for in-field analysis of iodide in seawater. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Functional Evaluation and Characterization of a Newly Developed Silicone Oil-Free Prefillable Syringe System

    Science.gov (United States)

    Yoshino, Keisuke; Nakamura, Koji; Yamashita, Arisa; Abe, Yoshihiko; Iwasaki, Kazuhiro; Kanazawa, Yukie; Funatsu, Kaori; Yoshimoto, Tsuyoshi; Suzuki, Shigeru

    2014-01-01

    The functionality of a newly developed silicone oil-free (SOF) syringe system, of which the plunger stopper is coated by a novel coating technology (i-coating™), was assessed. By scanning electron microscopy observations and other analysis, it was confirmed that the plunger stopper surface was uniformly covered with the designed chemical composition. A microflow imaging analysis showed that the SOF system drastically reduced both silicone oil (SO) doplets and oil-induced aggregations in a model protein formulation, whereas a large number of subvisible particles and protein aggregations were formed when a SO system was used. Satisfactory container closure integrity (CCI) was confirmed by means of dye and microorganism penetration studies. Furthermore, no significant difference between the break loose and gliding forces was observed in the former, and stability studies revealed that the SOF system could perfectly show the aging independence in break loose force observed in the SO system. The results suggest that the introduced novel SOF system has a great potential and represents an alternative that can achieve very low subvisible particles, secure CCI, and the absence of a break loose force. In particular, no risk of SO-induced aggregation can bring additional value in the highly sensitive biotech drug market. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 103:1520–1528, 2014 PMID:24643749

  20. Syringic Acid Extracted from Herba dendrobii Prevents Diabetic Cataract Pathogenesis by Inhibiting Aldose Reductase Activity

    Directory of Open Access Journals (Sweden)

    Xiaoyong Wei

    2012-01-01

    Full Text Available Objective. Effects of Syringic acid (SA extracted from dendrobii on diabetic cataract (DC pathogenesis were explored. Methods. Both in vitro and in vivo DC lens models were established using D-gal, and proliferation of HLEC exposed to SA was determined by MMT assay. After 60-day treatment with SA, rat lens transparency was observed by anatomical microscopy using a slit lamp. SA protein targets were extracted and isolated using 2-DE and MALDI TOF/TOF. AR gene expression was investigated using qRT-PCR. Interaction sites and binding characteristics were determined by molecule-docking techniques and dynamic models. Results. Targeting AR, SA provided protection from D-gal-induced damage by consistently maintaining lens transparency and delaying lens turbidity development. Inhibition of AR gene expression by SA was confirmed by qRT-PCR. IC50 of SA for inhibition of AR activity was 213.17 μg/mL. AR-SA binding sites were Trp111, His110, Tyr48, Trp20, Trp79, Leu300, and Phe122. The main binding modes involved hydrophobic interactions and hydrogen bonding. The stoichiometric ratio of non-covalent bonding between SA and AR was 1.0 to 13.3. Conclusion. SA acts to prevent DC in rat lenses by inhibiting AR activity and gene expression, which has potential to be developed into a novel drug for therapeutic management of DC.

  1. [Manual intrauterine aspiration using a Karmann syringe. Multicenter study in Sonora and Sinaloa, Mexico].

    Science.gov (United States)

    Rocha Cortes, F; Chacon Iñiguez, J; Amaro Patron, R; Ramon Alvarez Morales, J; Vargas Zepeda, D

    1996-03-01

    These are the results of a prospective, multicentric study carried out in five institutional hospitals in Sonora and Sinaloa, using Karmann syringe and cannulae for manual intrauterine aspiration in cases of incomplete abortion, dead and retained ovum, hidatiform mola and endometrial biopsy. Management data in 1046 patients, are described; methodology is shown, and demonstrating that it converts uterine emptying is a simple, efficacious and economical procedure, with a very low risk and it allows these patients management in an ambulatory way. From these results, and as it is demonstrated in the study, institutions may increase their programable resources as to amount of disposable beds, for other type of patients, and the offering of attention by surgeon, anesthetist, nurse and medication, as their hospital stay is minimal, and in most of the cases active anesthetist participation is not required. In the same way, it permits the patient a better relationship with the personal of the institution, and so, a more human care and the possibility of reintegrating the patient to a familiar environment, rapidly, and in good psychical and physical conditions.

  2. Direct Evidence of Egestion and Salivation of Xylella fastidiosa Suggests Sharpshooters Can Be "Flying Syringes".

    Science.gov (United States)

    Backus, Elaine A; Shugart, Holly J; Rogers, Elizabeth E; Morgan, J Kent; Shatters, Robert

    2015-05-01

    Xylella fastidiosa is unique among insect-transmitted plant pathogens because it is propagative but noncirculative, adhering to and multiplying on the cuticular lining of the anterior foregut. Any inoculation mechanism for X. fastidiosa must explain how bacterial cells exit the vector's stylets via the food canal and directly enter the plant. A combined egestion-salivation mechanism has been proposed to explain these unique features. Egestion is the putative outward flow of fluid from the foregut via hypothesized bidirectional pumping of the cibarium. The present study traced green fluorescent protein-expressing X. fastidiosa or fluorescent nanoparticles acquired from artificial diets by glassy-winged sharpshooters, Homalodisca vitripennis, as they were egested into simultaneously secreted saliva. X. fastidiosa or nanoparticles were shown to mix with gelling saliva to form fluorescent deposits and salivary sheaths on artificial diets, providing the first direct, conclusive evidence of egestion by any hemipteran insect. Therefore, the present results strongly support an egestion-salivation mechanism of X. fastidiosa inoculation. Results also support that a column of fluid is transiently held in the foregut without being swallowed. Evidence also supports (but does not definitively prove) that bacteria were suspended in the column of fluid during the vector's transit from diet to diet, and were egested with the held fluid. Thus, we hypothesize that sharpshooters could be true "flying syringes," especially when inoculation occurs very soon after uptake of bacteria, suggesting the new paradigm of a nonpersistent X. fastidiosa transmission mechanism.

  3. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  4. A research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang

    2010-01-01

    Radiation sterilization is widely applied in food processing, Pharmaceutical Manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. The output value of radiation sterilization industry reached 0.1% of the GDP in some advanced countries (America and Japan...), under this standard, its output value in Sichuan province would be RMB1.2 hundred million, but now our capacity and scale of this industry is less than RMB40million.Research shows: there are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the 'bottleneck' restrictions of capacity and Inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity for radiation sterilization, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  5. Ethylene oxide sterilization: how hospitals can adapt to the changes.

    Science.gov (United States)

    1994-12-01

    Ethylene oxide (EtO) gas sterilizers have been used by hospitals for over 40 years to sterilize surgical equipment and supplies that are heat sensitive or that cannot tolerate excessive moisture. However, in recent decades, EtO has been recognized as a potential mutagenic, reproductive, neurologic, and fire and explosion hazard to workers, and one agency has reportedly voted to classify EtO as carcinogenic to humans. Strict regulations concerning EtO exposure have been imposed by the Occupational Safety and Health Administration (OSHA), and the use of EtO, along with other toxic pollutants, is also being monitored by the Environmental Protection Agency (EPA) under the Clean Air Act. In addition, the use of chlorofluorocarbons (CFCs) as EtO diluents has focused attention on the EtO-CFC mixtures used in many sterilizers because CFCs have been linked to destruction of the ozone layer. Concerns about restrictive regulations related to these issues have prompted many hospitals to examine their use of EtO sterilization and propagated the misinformation that EtO sterilization is being phased out. In this article, we address some commonly asked questions regarding the use and regulation of EtO mixtures, as well as alternative sterilization agents and methods; provide two case studies illustrating how hospitals can evaluate various sterilization options; and summarize our conclusions and recommendations for hospitals facing decisions about sterilization techniques. For related topics, also see our Evaluation Update on endoscope reprocessors and our Hazard Report on improperly connected EtO-CFC cylinders to EtO sterilizers in this issue.

  6. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    Science.gov (United States)

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  7. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  8. Syringing method as an alternative to Śṛṇga therapy in Vātakaṇṭaka.

    Science.gov (United States)

    Joshi, Suma; Toshikhane, Sangeeta Hemant; Toshikhane, Hemant D

    2014-01-01

    Calcaneus forms the bone of the foot. Due to abnormal pressures, foot muscles and ligaments are stretched beyond their normal limits that lead to chronic plantar heel pain, among which calcaneal spur tops the list. In Ayurveda, it can be correlated to "Vātakaṇṭaka" (pricking sensation in the foot)-a painful condition of heel caused by its improper placement on the ground. To assess the effect of syringing method (modified Śṛṅga) in the treatment of Vātakaṇṭaka. A 10 ml syringe was for ease, hygiene, and to enable the case to be managed in the outpatient department. A diagnosed case of calcaneal spurs with pain, tenderness, and swelling visited KLE University's Shri BMK Ayurveda Hospital and Research Centre, Belgaum, Karnataka, India. After Snigdha Patrapoṭṭali sveda (a form of sudation therapy), bloodletting was performed by syringing method. In total procedure was performed for 4 times on the patient. Marked subjective relief was observed. Pain from 8 visual analog scale (VAS) came to 2 visual analog scale (VAS) and tenderness and swelling relived completely.

  9. Syringing method as an alternative to Śṛṇga therapy in Vātakaṇṭaka

    Directory of Open Access Journals (Sweden)

    Suma Joshi

    2014-01-01

    Full Text Available Calcaneus forms the bone of the foot. Due to abnormal pressures, foot muscles and ligaments are stretched beyond their normal limits that lead to chronic plantar heel pain, among which calcaneal spur tops the list. In Ayurveda, it can be correlated to "Vātakaṇṭaka" (pricking sensation in the foot-a painful condition of heel caused by its improper placement on the ground. To assess the effect of syringing method (modified Śṛṅga in the treatment of Vātakaṇṭaka. A 10 ml syringe was for ease, hygiene, and to enable the case to be managed in the outpatient department. A diagnosed case of calcaneal spurs with pain, tenderness, and swelling visited KLE University′s Shri BMK Ayurveda Hospital and Research Centre, Belgaum, Karnataka, India. After Snigdha Patrapoṭṭali sveda (a form of sudation therapy, bloodletting was performed by syringing method. In total procedure was performed for 4 times on the patient. Marked subjective relief was observed. Pain from 8 visual analog scale (VAS came to 2 visual analog scale (VAS and tenderness and swelling relived completely.

  10. Organic Extractives from Mentha spp. Honey and the Bee-Stomach: Methyl Syringate, Vomifoliol, Terpenediol I, Hotrienol and Other Compounds

    Directory of Open Access Journals (Sweden)

    Igor Jerković

    2010-04-01

    Full Text Available The GC and GC/MS analyses of the solvent organic extractive from the stomach of the bees, having collected Mentha spp. nectar, revealed the presence of methyl syringate (6.6%, terpendiol I (5.0% and vomifoliol (3.0% that can be attributed to the plant origin. Other major compounds from the bee-stomach were related to the composition of cuticular waxes and less to pheromones. Organic extractivesfrom Mentha spp. honey were obtained by solvent-free headspace solid-phase microextraction (HS-SPME and ultrasonic solvent extraction (USE and analyzed by GC and GC/MS. The major honey headspace compounds were hotrienol (31.1%–38.5%, 2-methoxy-4-methylphenol (0.5–6.0%, cis- and trans-linalool oxides (0.9–2.8%, linalool (1.0–3.1% and neroloxide (0.9–1.9%. Methyl syringate was the most abundant compound (38.3-56.2% in the honey solvent extractives followed by vomifoliol (7.0–26.6%. Comparison of the honey organic extractives with the corresponding bee-stomach extractive indicated that methyl syringate and vomofoliol were transferred to the honey while terpendiol I was partially transformed to hotrienol in ripened honey.

  11. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    Science.gov (United States)

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  12. Achieving the Recommended Endotracheal Tube Cuff Pressure: A Randomized Control Study Comparing Loss of Resistance Syringe to Pilot Balloon Palpation

    Directory of Open Access Journals (Sweden)

    Fred Bulamba

    2017-01-01

    Full Text Available Background. Both under- and overinflation of endotracheal tube cuffs can result in significant harm to the patient. The optimal technique for establishing and maintaining safe cuff pressures (20–30 cmH2O is the cuff pressure manometer, but this is not widely available, especially in resource-limited settings where its use is limited by cost of acquisition and maintenance. Therefore, anesthesia providers commonly rely on subjective methods to estimate safe endotracheal cuff pressure. This study set out to determine the efficacy of the loss of resistance syringe method at estimating endotracheal cuff pressures. Methods. This was a randomized clinical trial. We enrolled adult patients scheduled to undergo general anesthesia for elective surgery at Mulago Hospital, Uganda. Study participants were randomized to have their endotracheal cuff pressures estimated by either loss of resistance syringe or pilot balloon palpation. The pressures measured were recorded. Results. One hundred seventy-eight patients were analyzed. 66.3% (59/89 of patients in the loss of resistance group had cuff pressures in the recommended range compared with 22.5% (20/89 from the pilot balloon palpation method. This was statistically significant. Conclusion. The loss of resistance syringe method was superior to pilot balloon palpation at administering pressures in the recommended range. This method provides a viable option to cuff inflation.

  13. Organic extractives from Mentha spp. honey and the bee-stomach: methyl syringate, vomifoliol, terpenediol I, hotrienol and other compounds.

    Science.gov (United States)

    Jerković, Igor; Hegić, Gordana; Marijanović, Zvonimir; Bubalo, Dragan

    2010-04-22

    The GC and GC/MS analyses of the solvent organic extractive from the stomach of the bees, having collected Mentha spp. nectar, revealed the presence of methyl syringate (6.6%), terpendiol I (5.0%) and vomifoliol (3.0%) that can be attributed to the plant origin. Other major compounds from the bee-stomach were related to the composition of cuticular waxes and less to pheromones. Organic extractives from Mentha spp. honey were obtained by solvent-free headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE) and analyzed by GC and GC/MS. The major honey headspace compounds were hotrienol (31.1%-38.5%), 2-methoxy-4-methylphenol (0.5-6.0%), cis- and trans-linalool oxides (0.9-2.8%), linalool (1.0-3.1%) and neroloxide (0.9-1.9%). Methyl syringate was the most abundant compound (38.3-56.2%) in the honey solvent extractives followed by vomifoliol (7.0-26.6%). Comparison of the honey organic extractives with the corresponding bee-stomach extractive indicated that methyl syringate and vomofoliol were transferred to the honey while terpendiol I was partially transformed to hotrienol in ripened honey.

  14. Analysis of event logs from syringe pumps: a retrospective pilot study to assess possible effects of syringe pumps on safety in a university hospital critical care unit in Germany.

    Science.gov (United States)

    Kastrup, Marc; Balzer, Felix; Volk, Thomas; Spies, Claudia

    2012-07-01

    Medication errors occur in approximately one out of five doses in a typical hospital setting. Patients in the intensive care unit (ICU) are particularly susceptible to errors during the application of intravenous drugs as they receive numerous potent drugs applied by syringe pumps. The aim of this study was to analyse the effects on potential harmful medication errors and to address factors that have potential for improving medication safety after the introduction of a standardized drug library into syringe pumps with integrated decision support systems. A team of physicians and nurses developed a dataset that defined standardized drug concentrations, application rates and alert limits to prevent accidental overdosing of intravenous medications. This dataset was implemented in 100 syringe pumps with the ability to log programming errors, alerts, reprogramming events and overrides ('smart pumps'). In this retrospective pilot study, all pump-related transaction data were obtained from the pump logs, by downloading the data from the pumps, covering 20 months of use between 1 April 2008 and 30 November 2009. Patient data were gathered from the electronic patient charts. The study was performed in a cardiothoracic ICU of the Charité University Hospital, Berlin, Germany. A total of 7884 patient treatment days and 133,601 infusion starts were evaluated. The drug library with the features of the dose rate was used in 92.8% of the syringe pump starts, in 1.5% of the starts a manual dosing mode without the use of the drug library was used and in 5.7% of the starts the mode 'mL/h', without any calculation features, was used. The most frequently used drugs were vasoactive drugs, followed by sedation medication. The user was alerted for a potentially harmful overdosing in 717 cases and in 66 cases the pumps were reprogrammed after the alert. During the early morning hours a higher rate of alarms was generated by the pumps, compared with the rest of the day. Syringe pumps with

  15. Sterility and meeting competitiveness of medfly, Ceratitis Capitata (Wiedemann)

    International Nuclear Information System (INIS)

    Taein-Tun; Molly-Maung-Maung

    2001-01-01

    The basic methodology in the determination of sterilising dosage in male med flies and mating competitiveness with the normal males was carried out in the laboratory. Application of the Sterile Insect Technique (S.I.T.) by three irradiation dosages on Seib-6096 pupae results in sterility when dosage increased. A lower mating competitiveness was observed with the increase in sterility value. This value was determined from the corrected egg hatch percent. The resulting data showed that irradiation dosage of γ 10.0 Krad gave a good advantage to suppress the population in the next generation. The method suggested a good application in the control and eradication of fruit flies. (author)

  16. Sterile neutrinos as the origin of dark and baryonic matter.

    Science.gov (United States)

    Canetti, Laurent; Drewes, Marco; Shaposhnikov, Mikhail

    2013-02-08

    We demonstrate for the first time that three sterile neutrinos alone can simultaneously explain neutrino oscillations, the observed dark matter, and the baryon asymmetry of the Universe without new physics above the Fermi scale. The key new point of our analysis is leptogenesis after sphaleron freeze-out, which leads to resonant dark matter production, evading thus the constraints on sterile neutrino dark matter from structure formation and x-ray searches. We identify the range of sterile neutrino properties that is consistent with all known constraints. We find a domain of parameters where the new particles can be found with present day experimental techniques, using upgrades to existing experimental facilities.

  17. The processing technology of bread crumbs sterilization by irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Li Zhengkui; Zhao Yongfu; Zhang Weidong; Jin Jie; Wu Lei; Wang Xinghai

    2003-01-01

    The processing technology of bread crumbs sterilization by irradiation was studied. The results demonstrated that dose heterogeneity had osculatory connection with pile height and turning, sterilization effect had positive correlation with the irradiation dose and negative correlation with colour. Compared with the CK, the content of crud protein, fat, carbohydrate, microelement and amino acid in irradiated bread crumbs had no obvious change. It is recommended that the range of best sterilization dose be 6-10 kGy and the shelf time of bread crumbs be extended to one year

  18. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... there were no cultivable bacteria, whereas bacteria were cultivated in all positive control samples. In eight of 10 PCR samples no bacterial DNA was detected. The most frequent bacteria in the remaining non-sterile parotid saliva samples and positive control samples were non-haemolytical streptococci...

  19. Recurrent sterile abscesses following aluminium adjuvant-containing vaccines.

    Science.gov (United States)

    Klein, Nicola P; Edwards, Kathryn M; Sparks, Robert C; Dekker, Cornelia L

    2009-01-01

    Abscess formation following immunisation is a previously reported complication, generally associated with microbial contamination of the vaccine. Less commonly, such abscesses have been sterile. Here we describe two children evaluated in the Center for Disease Control and Prevention (CDC)-funded Clinical Immunization Safety Assessment (CISA) network who developed recurrent sterile abscesses after administration of vaccines containing aluminium adjuvant, either individually or in combination. Although the abscesses healed without sequelae, these occurrences support an association between receipt of aluminium adjuvant and sterile abscesses in susceptible patients. For patients with similar symptoms, clinicians may wish to choose a vaccine formulation containing the least amount of aluminium adjuvant.

  20. Sterilization of experimental animal feeds with high energy electron beam

    International Nuclear Information System (INIS)

    Takekawa, Tetsuya; Shakudo, Taketomi; Furuta, Masakazu; Tada, Mikiro

    2005-01-01

    Penetration range and depth-dose distribution of 10 MeV electrons within commercial packages of experimental animal feeds were examined with a high power electron accelerator for verification of the application of high energy electron beam irradiation to sterilize experimental animal feeds. Optimum packaging sizes were proposed based on the experimental results. The change of the vitamins and the efficacy of the sterilization by the irradiation were also studied. It is confirmed that the sterilization of experimental animal feeds by 10 MeV electron beam has been completely practical. (author)

  1. The search for sterile neutrinos with SOX-Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Altenmüller, K., E-mail: konrad.altenmueller@ph.tum.de; Agostini, M.; Appel, S. [Technische Universität München, Physik-Department and Excellence Cluster Universe (Germany); Bellini, G. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Benziger, J. [Princeton University, Chemical Engineering Department (United States); Berton, N. [Centre de Saclay, IRFU, Commissariat a l’Energie Atomique et aux Energies Alternatives (France); Bick, D. [Universität Hamburg, Institut für Experimentalphysik (Germany); Bonfini, G. [INFN Laboratori Nazionali del Gran Sasso (Italy); Bravo, D. [Virginia Polytechnic Institute and State University, Physics Department (United States); Caccianiga, B. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Calaprice, F. [Princeton University, Physics Department (United States); Caminata, A. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Cavalcante, P. [INFN Laboratori Nazionali del Gran Sasso (Italy); Chepurnov, A. [Moscow State University Skobeltsyn Institute of Nuclear Physics (Russian Federation); Cribier, M. [Centre de Saclay, IRFU, Commissariat a l’Energie Atomique et aux Energies Alternatives (France); D’Angelo, D. [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Davini, S. [Gran Sasso Science Institute (INFN) (Italy); Derbin, A. [St. Petersburg Nuclear Physics Institute (Russian Federation); Noto, L. di [Università degli Studi e INFN, Dipartimento di Fisica (Italy); Drachnev, I. [Gran Sasso Science Institute (INFN) (Italy); and others

    2016-12-15

    The aim of the SOX-Borexino project is to verify or falsify the existence of eV-scale sterile neutrinos. The existence of sterile neutrinos is suspected because of several anomalies, which were observed in previous experiments. A ~3.7 PBq electron antineutrino source made of {sup 144}Ce will be installed below the Borexino detector at LNGS, Italy, to search for short-baseline oscillations of active-to-sterile neutrinos within the detector volume. Source delivery and beginning of data acquisition is planned for end of 2016, preliminary results are expected already in 2017.

  2. Committee Opinion No. 695: Sterilization of Women: Ethical Issues and Considerations.

    Science.gov (United States)

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  3. Committee Opinion No 695 Summary: Sterilization of Women: Ethical Issues and Considerations.

    Science.gov (United States)

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  4. [Sterilization by ovariotexy, a reversible technic].

    Science.gov (United States)

    Wood, C; Leeton, J

    1970-01-01

    6 women were sterilized by ovariotexy, enclosing the ovaries in silastic bags within the peritoneum. The patients ranged in age from 23-33 years, in parity from 1-5, with indications such as hemophiliac and anencephalic children, mental illness, nephrotic syndrome, multiple contraceptive failures, and divorce. The surgical technique involved section of the ovarian ligament and incision of the peritonium from the tube to the ovary. The ovary was fastened in a Silastic bag with Silastic adhesive type A (Dow Corning Corporation), and held in place by suturing it to the ovarian pedicle. The bag and ovary were placed in a pocket created by dissecting the external half of the posterior fold of the broad ligament as far as possible from the tube. The peritoneum was closed and sutured to the mesosalpinx above the round ligament with atraumatic chromic catgut 000. There were no postoperative complications up to 12 days, no pregnancies and no gynecologic findings during follow-up of 6-18 months. 1 patient tested still had tubal patency on insufflation 6 days after the operation. 2 temperature curves recorded were biphasic. It is too soon to learn whether this method will be reversible, but use of silastic should prevent adhesions while providing another mechanical barrier between ovum and sperm.

  5. Infection Risk in Sterile Operative Procedures.

    Science.gov (United States)

    Tacconelli, Evelina; Müller, Niklas F; Lemmen, Sebastian; Mutters, Nico T; Hagel, Stefan; Meyer, Elisabeth

    2016-04-22

    The main objective of hospital hygiene and infection prevention is to protect patients from preventable nosocomial infections. It was recently stated that the proper goal should be for zero infection rates in sterile surgical procedures. In this article, we attempt to determine whether this demand is supported by the available literature. We systematically searched the Medline and EMBASE databases for studies published in the last 10 years on the efficacy of infection control measures and carried out a meta-analysis according to the PRISMA tool. We used the following search terms: "aseptic surgery," "intervention," "surgical site infection," "nosocomial infection," "intervention," and "prevention." 2277 articles were retrieved, of which 204 were acquired in full text and analyzed. The quantitative analysis included 7 prospective cohort studies on the reduction of nosocomial infection rates after aseptic surgery. The measures used included training sessions, antibiotic prophylaxis, and operative-site disinfection and cleaning techniques. These interventions succeeded in reducing postoperative wound infections (relative risk (RR] 0.99 [0.98; 1.00]). Subgroup analyses on antibiotic prophylaxis (RR 0.99 [0.98; 1.01]) and noncontrolled trials (RR 0.97 [0.92; 1.02]) revealed small, insignificant effects. A multimodal approach with the participation of specialists from various disciplines can further reduce the rate of postoperative infection. A reduction to zero is not realistic and is not supported by available evidence.

  6. Belgian experience with radiation technologies for sterilization

    International Nuclear Information System (INIS)

    Bonet, H.; Dardenne, P.; Herier, A.

    1998-01-01

    Belgium pioneered in non energetic applications of nuclear science. In 1970, the National Institute for Radioisotopes (IRE) was founded on the ground of the experience acquired at the CEN/SCK, for developing nuclear techniques oriented to the well-being of population. In 1978 IRE started operation of 2 γ-irradiation units with a 2.25 million Ci Co 60 , source having a capacity for sterilization of more than 100 m 3 of product per day. this installation is currently operated by Griffith-Mediris (Group Griffith Micro Science) and has accumulated 20 years of experience for irradiation of foodstuffs, medical appliances and pharmaceuticals. In 1986, IRE was producing radioisotopes from accelerators and joined UCL for founding Ion Beam Applications (IBA) company which shortly became the world leader for design and delivery of cyclotrons. More recently, on the basis of French CEA patent, IBA developed the Rhodotron, an e-beam accelerator, with an X-ray option, which is now facing commercial success i area of ionization of food and medical appliances. IRE developed also expertise for the back-end of these activities i.e. final disposal of radioactive sealed source and dismantling of the installations. (author)

  7. Comparative evaluation of the amount of debris extruded apically using conventional syringe, passive ultrasonic irrigation and EndoIrrigator Plus system: Anin vitrostudy.

    Science.gov (United States)

    Shetty, Vidhi Prabhakar; Naik, Balaram Damodar; Pachlag, Amit Kashinath; Yeli, Mahantesh Mrityunjay

    2017-01-01

    The aim of this study is to compare the effects of conventional syringe, passive ultrasonic irrigation (PUI), and EndoIrrigator Plus on the amount of apically extruded debris. Thirty extracted human mandibular premolars were selected and randomly assigned to three groups ( n = 10). The root canals were irrigated with conventional syringe, PUI, and EndoIrrigator Plus. Sodium hypochlorite was used as an irrigant, and debris was collected in a previously described experimental model (Myers and Montgomery 1991). It was then stored in an incubator at 37°C for 10 days to evaporate the irrigant before weighing the dry debris. The mean weight of debris was assessed, one-way analysis of variance was used for comparison of values, and post hoc Tukey's test was used between groups ( P = 0.05). The EndoIrrigator Plus group extruded significantly less debris than PUI and conventional syringe groups ( P extruded significantly less debris than conventional syringe irrigation group ( P extruded significantly less debris than the PUI system and the conventional syringe irrigation system, 3. PUI system extruded significantly less debris than the conventional syringe irrigation system.

  8. [Safe injection rooms and police crackdowns in areas with heavy drug dealing. Evaluation by counting discarded syringes collected from the public space].

    Science.gov (United States)

    Vecino, Carmen; Villalbí, Joan R; Guitart, Anna; Espelt, Albert; Bartroli, Montserrat; Castellano, Yolanda; Brugal, M Teresa

    2013-01-01

    The evolution of drug injection in public places is analysed using as indicator the number of syringes collected from public spaces, evaluating as well the influence of public health harm reduction interventions and of police actions, with a before and after quasi experimental study. Monthly syringe counts on the semester before and after each intervention were compared both in the involved district and in the city as a whole, using the U and z tests with a 95% confidence level. The average number of collected syringes drops from 13.132 in 2004 to 3.190 in 2012. Comparing indicators before and after health and police interventions, the opening of a facility with a supervised drug consumption room in the inner city was associated with a huge reduction in the number of abandoned syringes in the city, while its number did not rise in the district where the facility was located. The subsequent opening of another drug consumption room did not have a significant impact in collected syringes in the area. Some police interventions in 2005-2006 and 2011 had a significant impact in the indicators of the involved districts, while others did not. Harm reduction programs might have a favourable impact on drug injection in public spaces and related syringe presence. Some police interventions appear to have an impact while others do not or just have a modest local and temporary effect.

  9. The sterile insect technique for controlling populations of Aedes albopictus (Diptera: Culicidae) on Reunion Island: mating vigour of sterilized males.

    Science.gov (United States)

    Oliva, Clelia F; Jacquet, Maxime; Gilles, Jeremie; Lemperiere, Guy; Maquart, Pierre-Olivier; Quilici, Serge; Schooneman, François; Vreysen, Marc J B; Boyer, Sebastien

    2012-01-01

    Reunion Island suffers from high densities of the chikungunya and dengue vector Aedes albopictus. The sterile insect technique (SIT) offers a promising strategy for mosquito-borne diseases prevention and control. For such a strategy to be effective, sterile males need to be competitive enough to fulfil their intended function by reducing wild mosquito populations in natura. We studied the effect of irradiation on sexual maturation and mating success of males, and compared the sexual competitiveness of sterile versus wild males in the presence of wild females in semi-field conditions. For all untreated or sterile males, sexual maturation was completed within 13 to 20 h post-emergence and some males were able to inseminate females when 15 h old. In the absence of competition, untreated and sterile males were able to inseminate the same number of virgin females during 48 h, in small laboratory cages: an average of 93% of females was inseminated no matter the treatment, the age of males, and the sex ratio. Daily mating success of single sterile males followed the same pattern as for untreated ones, although they inseminated significantly fewer females after the ninth day. The competitiveness index of sterile males in semi-field conditions was only 0.14 when they were released at 1-day old, but improved to 0.53 when the release occurred after a 5-day period in laboratory conditions. In SIT simulation experiments, a 5:1 sterile to wild male ratio allowed a two-fold reduction of the wild population's fertility. This suggests that sterile males could be sufficiently competitive to mate with wild females within the framework of an SIT component as part of an AW-IPM programme for suppressing a wild population of Ae. albopictus in Reunion Island. It will be of interest to minimise the pre-release period in controlled conditions to ensure a good competitiveness without increasing mass rearing costs.

  10. Transcriptional regulation of male-sterility in 7B-1 male-sterile tomato mutant.

    Directory of Open Access Journals (Sweden)

    Vahid Omidvar

    Full Text Available The 7B-1 tomato (Solanum lycopersicum L. cv Rutgers is a male-sterile mutant with enhanced tolerance to abiotic stress, which makes it a potential candidate for hybrid seed breeding and stress engineering. To underline the molecular mechanism regulating the male-sterility in 7B-1, transcriptomic profiles of the 7B-1 male-sterile and wild type (WT anthers were studied using mRNA sequencing (RNA-Seq. In total, 768 differentially expressed genes (DEGs were identified, including 132 up-regulated and 636 down-regulated transcripts. Gene ontology (GO enrichment analysis of DEGs suggested a general impact of the 7B-1 mutation on metabolic processes, such as proteolysis and carbohydrate catabolic process. Sixteen candidates with key roles in regulation of anther development were subjected to further analysis using qRT-PCR and in situ hybridization. Cytological studies showed several defects associated with anther development in the 7B-1 mutant, including unsynchronized anther maturation, dysfunctional meiosis, arrested microspores, defect in callose degradation and abnormal tapetum development. TUNEL assay showed a defect in programmed cell death (PCD of tapetal cells in 7B-1 anthers. The present study provides insights into the transcriptome of the 7B-1 mutant. We identified several genes with altered expression level in 7B-1 (including beta-1,3 glucanase, GA2oxs, cystatin, cysteine protease, pectinesterase, TA29, and actin that could potentially regulate anther developmental processes, such as meiosis, tapetum development, and cell-wall formation/degradation.

  11. Possibilities of sterilizing nutrient media used to grow tissue cultures

    International Nuclear Information System (INIS)

    Veber, P.; Leshko, Ya.; Gana, L.; Yankovicheva, T.; Yurmanova, K.

    1976-01-01

    Effects of radiosterilization on the properties of liquid and powdery Eagle's media and on inactivated calf and horse sera are described. It is shown that radiosterilization may be employed to sterilize biological agents required for in vitro cell cultivation. (author)

  12. Postpartum Sterilization Choices Made by HIV-Infected Women

    Directory of Open Access Journals (Sweden)

    Gretchen S. Stuart

    2005-01-01

    Full Text Available Objective. To assess if HIV-infected women made different choices for postpartum sterilization after implementation of the Pediatric AIDS Clinical Trials Group protocol 076 (November 1, 1994 compared to before implementation.

  13. Are there sterile neutrinos at the eV scale?

    Science.gov (United States)

    Kopp, Joachim; Maltoni, Michele; Schwetz, Thomas

    2011-08-26

    New predictions for the antineutrino flux from nuclear reactors suggest that reactor experiments may have measured a deficit in this flux, which can be interpreted in terms of oscillations between the known active neutrinos and new sterile states. We perform a reanalysis of global short-baseline neutrino oscillation data in a framework with one or two sterile neutrinos. While one sterile neutrino is still not sufficient to reconcile the signals suggested by reactor experiments and by the LSND and MiniBooNE experiments with null results from other searches, we find that, with the new reactor flux prediction, the global fit improves considerably when two sterile neutrinos are introduced. © 2011 American Physical Society

  14. Compulsory Sterilization: The Change in India's Population Policy

    Science.gov (United States)

    Gulhati, Kaval

    1977-01-01

    Reviews India's previous stand regarding family planning which favored the notion that economic development would provide the incentive for fertility control. Recent recommendations, however, include raising minimum marriage age for girls and increasing incentives for acceptance of sterilization. (CS)

  15. Steam sterilization costs: a guide for the central service manager.

    Science.gov (United States)

    O'Shaughnessy, K L

    1993-07-01

    The Nassau County Medical Center CS department, East Meadow, New York, was faced with a staff layoff and an increased workload. With some hard thinking and strong staff support, new processes/systems were designed to save time and money. These included outsourcing the sterilization of "easy" trays, instituting a case cart program and developing custom packs. In order to determine where savings could be had, it was first important to examine current costs. By breaking the costs of sterilization processing down into an average cost per load, a formula was developed that helped determine many additional cost comparisons for the department. For example, the cost analysis formula could be used by CS departments to determine the cost-effectiveness of off-site sterilization, to compare using disposable vs. reusable items and to determine costs for EtO sterilization and aeration.

  16. Protozoa and their bacterial prey colonize sterile soil fast

    DEFF Research Database (Denmark)

    Altenburger, Andreas; Ekelund, Flemming; Jacobsen, Carsten Suhr

    2010-01-01

    We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them to the at......We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them...... to the atmosphere for a period of 14 months. Bacteria and flagellates occurred in high numbers after 25 days. Ciliates reached high abundance levels after 137 days, followed by amoebae after 245 days. Numbers of distinguishable protozoan morpho-types increased until 245 days after exposure and declined thereafter...

  17. Influence of reactive oxygen species on the sterilization of microbes

    Science.gov (United States)

    The influence of reactive oxygen species on living cells, including various microbes, is discussed. A sterilization experiment with bacterial endospores reveals that an argoneoxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby indicating that oxygen radic...

  18. ( Atp9) gene between cytoplasmic male sterile line and its ...

    African Journals Online (AJOL)

    Administrator

    2011-09-07

    , the atp9 gene in soybeans was cloned from a soybean cytoplasmic male sterile line NJCMS2A and its maintainer line NJCMS2B. Sequence alignment was performed, and protein structures were analyzed and compared ...

  19. Design, Construction and Evaluation of a Dry Solar Sterilizer

    International Nuclear Information System (INIS)

    Hernández Fereira, Arcelio A.

    2017-01-01

    The objective of the work was the search of an alternative for sterilization using solar energy. For such purposes, a dry solar sterilizer of 4276 cm3 capacity was designed, constructed and evaluated. Potential users would be rural medical posts in areas without electricity, health posts in military units under field conditions, and experimental microbiology stations. The evaluation included the determination of the energy efficiency of the sterilizer, the economic evaluation against other variants and the biological safety assessment. The developed equipment reached the sterilization temperature for levels of the direct component of the solar radiation higher than 300 W/m2 in 14 minutes, corresponding to an average heating rate of 13 0C/minute, higher than that of an electric furnace. Its energy efficiency with direct solar radiation of 310.5 W/m2 was 53.79%. The equipment is of easy construction, simple operation and very low cost. (author)

  20. Radiation sterilization of traditional medicine drugs in Vietnam

    International Nuclear Information System (INIS)

    Hang, N.D.; Canh, T.T.; Thuy, T.T.

    1995-01-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author)

  1. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    Science.gov (United States)

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of

  2. On-line lab-in-syringe cloud point extraction for the spectrophotometric determination of antimony.

    Science.gov (United States)

    Frizzarin, Rejane M; Portugal, Lindomar A; Estela, José M; Rocha, Fábio R P; Cerdà, Victor

    2016-02-01

    Most of the procedures for antimony determination require time-consuming sample preparation (e.g. liquid-liquid extraction with organic solvents), which are harmful to the environment. Because of the high antimony toxicity, a rapid, sensitive and greener procedure for its determination becomes necessary. The goal of this work was to develop an analytical procedure exploiting for the first time the cloud point extraction on a lab-in-syringe flow system aiming at the spectrophotometric determination of antimony. The procedure was based on formation of an ion-pair between the antimony-iodide complex and H(+) followed by extraction with Triton X-114. The factorial design showed that the concentrations of ascorbic acid, H2SO4 and Triton X-114, as well as second and third order interactions were significant at the 95% confidence level. A Box-Behnken design was applied to obtain the response surfaces and to identify the critical values. System is robust at the 95% confidence level. A linear response was observed from 5 to 50 µg L(-1), described by the equation A=0.137+0.050C(Sb) (r=0.998). The detection limit (99.7% confidence level), the coefficient of variation (n=5; 15 µg L(-1)) and the sampling rate was estimated at 1.8 µg L(-1), 1.6% and 16 h(-1), respectively. The procedure allows quantification of antimony in the concentrations established by environmental legislation (6 µg L(-1)) and it was successfully applied to the determination of antimony in freshwater samples and antileishmanial drugs, yielding results in agreement with those obtained by HGFAAS at the 95% confidence level. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Housing instability among people who inject drugs: results from the Australian needle and syringe program survey.

    Science.gov (United States)

    Topp, Libby; Iversen, Jenny; Baldry, Eileen; Maher, Lisa

    2013-08-01

    High rates of substance dependence are consistently documented among homeless people, and are associated with a broad range of negative outcomes among this population. Investigations of homelessness among drug users are less readily available. This study examined the prevalence and correlates of housing instability among clients of needle syringe programs (NSPs) via the Australian NSP Survey, annual cross-sectional seroprevalence studies among NSP attendees. Following self-completion of a brief, anonymous survey and provision of a capillary blood sample by 2,396 NSP clients, multivariate logistic regressions identified the variables independently associated with housing instability. Nineteen percent of ANSPS participants reported current unstable housing, with primary ('sleeping rough'; 5 %), secondary (staying with friends/relatives or in specialist homelessness services; 8 %), and tertiary (residential arrangements involving neither secure lease nor private facilities; 6 %) homelessness all evident. Extensive histories of housing instability were apparent among the sample: 66 % reported at least one period of sleeping rough, while 77 % had shifted between friends/relatives (73 %) and/or resided in crisis accommodation (52 %). Participants with a history of homelessness had cycled in and out of homelessness over an average of 10 years; and one third reported first being homeless before age 15. Compared to their stably housed counterparts, unstably housed participants were younger, more likely to be male, of Indigenous Australian descent, and to report previous incarceration; they also reported higher rates of key risk behaviors including public injecting and receptive sharing of injecting equipment. The high prevalence of both historical and current housing instability among this group, particularly when considered in the light of other research documenting the many adverse outcomes associated with this particular form of disadvantage, highlights the need

  4. Resistance force for intraocular lens insertion through lens cartridges and syringe-type injectors.

    Science.gov (United States)

    Usui, Masahiko; Tanaka, Takao

    2015-08-01

    To measure and compare the resistance force for intraocular lens (IOL) insertion using 5 syringe-type injector systems. Tokyo Medical University and laboratory in Kowa Co., Tokyo, Japan. Experimental study. Intraocular lenses were inserted into the lens capsular bag of porcine eyes after phacoemulsification using 5 implantation systems (Groups A, B, C, D, and E). For each system, the resistance force for IOL insertion to the lens capsular bag of porcine eyes was measured using an automated force gauge system. For control, the resistance force for IOL delivery into a plastic dish was measured. Changes in the resistance force and its curve and maximum value were evaluated. The mean total area under the curve (AUC) was compared. Data were statistically analyzed. For all groups, the mean resistance forces were 17.2, 6.3, 4.2, 20.7, and 2.3 newtons (N), respectively, in porcine eyes, and 14.4, 5.8, 4.5, 12.6, and 2.2 N in controls. The mean sizes of the total AUC were 43 371, 8465, 6771, 30 306, and 2334 pixels in porcine eyes and 40 940, 7080, 6876, 20 710, and 2215 pixels in controls; the correlation coefficients between the resistance forces and the sizes of the total area were 0.576, 0.113, 0.346, 0.726, and 0.933 in porcine eyes and 0.707, 0.557, 0.914, 0.951, and 0.893 in controls. Resistance force and its curve were clarified in 5 IOL implantation systems. Appropriate IOL and injector selection may be achieved after clarifying resistance force and its waveform during IOL insertion. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015. Published by Elsevier Inc.

  5. Spectrophotometric determination of irrigant extrusion using passive ultrasonic irrigation, EndoActivator, or syringe irrigation.

    Science.gov (United States)

    Rodríguez-Figueroa, Carolina; McClanahan, Scott B; Bowles, Walter R

    2014-10-01

    Sodium hypochlorite (NaOCl) irrigation is critical to endodontic success, and several new methods have been developed to improve irrigation efficacy (eg, passive ultrasonic irrigation [PUI] and EndoActivator [EA]). Using a novel spectrophotometric method, this study evaluated NaOCl irrigant extrusion during canal irrigation. One hundred fourteen single-rooted extracted teeth were decoronated to leave 15 mm of the root length for each tooth. Cleaning and shaping of the teeth were completed using standardized hand and rotary instrumentation to an apical file size #40/0.04 taper. Roots were sealed (not apex), and 54 straight roots (n = 18/group) and 60 curved roots (>20° curvature, n = 20/group) were included. Teeth were irrigated with 5.25% NaOCl by 1 of 3 methods: passive irrigation with needle, PUI, or EA irrigation. Extrusion of NaOCl was evaluated using a pH indicator and a spectrophotometer. Standard curves were prepared with known amounts of irrigant to quantify amounts in unknown samples. Irrigant extrusion was minimal with all methods, with most teeth showing no NaOCl extrusion in straight or curved roots. Minor NaOCl extrusion (1-3 μL) in straight roots or curved roots occurred in 10%-11% of teeth in all 3 irrigant methods. Two teeth in both the syringe irrigation and the EA group extruded 3-10 μL of NaOCl. The spectrophotometric method used in this study proved to be very sensitive while providing quantification of the irrigant levels extruded. Using the PUI or EA tip to within 1 mm of the working length appears to be fairly safe, but apical anatomy can vary in teeth to allow extrusion of irrigant. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. Needle and syringe programs in Yunnan, China yield health and financial return

    Directory of Open Access Journals (Sweden)

    Xun Zhuang

    2011-04-01

    Full Text Available Abstract Background As a harm reduction strategy in response to HIV epidemics needle and syringes programs (NSPs were initiated throughout China in 2002. The effectiveness of NSPs in reducing the spread of infection in such an established epidemic is unknown. In this study we use data from Yunnan province, the province most affected by HIV in China, to (1 estimate the population benefits in terms of infections prevented due to the programs; (2 calculate the cost-effectiveness of NSPs. Methods We developed a mathematical transmission model, informed by detailed behavioral and program data, which accurately reflected the unique HIV epidemiology among Yunnan injecting drug users (IDUs in the presence of NSPs. We then used the model to estimate the likely epidemiological and clinical outcomes without NSPs and conducted a health economics analysis to determine the cost-effectiveness of the program. Results It is estimated that NSPs in Yunnan have averted approximately 16-20% (5,200-7,500 infections of the expected HIV cases since 2002 and led to gains of 1,300-1,900 DALYs. The total $1.04 million spending on NSPs from 2002 to 2008 has resulted in an estimated cost-saving over this period of $1.38-$1.97 million due to the prevention of HIV and the associated costs of care and management. Conclusion NSPs are not only cost-effective but cost-saving in Yunnan. Significant scale-up of NSPs interventions across China and removal of the societal and political barriers that compromise the effects of NSPs should be a health priority of the Chinese government.

  7. How self-interactions can reconcile sterile neutrinos with cosmology.

    Science.gov (United States)

    Hannestad, Steen; Hansen, Rasmus Sloth; Tram, Thomas

    2014-01-24

    Short baseline neutrino oscillation experiments have shown hints of the existence of additional sterile neutrinos in the eV mass range. However, such neutrinos seem incompatible with cosmology because they have too large of an impact on cosmic structure formation. Here we show that new interactions in the sterile neutrino sector can prevent their production in the early Universe and reconcile short baseline oscillation experiments with cosmology.

  8. Sterilization of Lung Matrices by Supercritical Carbon Dioxide.

    Science.gov (United States)

    Balestrini, Jenna L; Liu, Angela; Gard, Ashley L; Huie, Janet; Blatt, Kelly M S; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J; Mecham, Robert P; Wilcox, Elise C; Niklason, Laura E

    2016-03-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10(-6) in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes.

  9. Pharmaceutical aerosols. Study of their gamma radiation sterilization

    International Nuclear Information System (INIS)

    Sebert, P.

    1984-10-01

    The gamma radiation sterilization of pharmaceutical aerosols was studied. The following topics were investigated: radiosterilization of nitrogen protoxide used as a propellant; radiosterilization of packaging materials (aluminium containers, plastics valves); radio-sterilization of excipients and active ingredients. Most of the investigated materials proved to be stable to irradiation (2,5 Mrads) from pharmacopoeial aspect. Stability tests of the preparations packaged showed no change in the parameters investigated [fr

  10. Dosimetry intercomparisons in European medical device sterilization plants

    DEFF Research Database (Denmark)

    Miller, A.; Sharpe, P.H.G.

    2000-01-01

    Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy of the o......Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy...

  11. Gamma radiations an effective way of monoclonal antibodies sterilization

    International Nuclear Information System (INIS)

    Lenay Barrera Barroso, Lenay; Otero Abreu, Isabel; Rodriguez Napoles, Dania; Bulte Ocanna, Dubhe; Caballero, Idania

    2006-01-01

    The sterilization for radiations of pharmaceutical products is an effective, sure and reliable procedure; that it have been proving technically and grateful for different pharmacopoeia. The Monoclonal Antibodies (Acm) produced in the Center of Molecular Immunology (CIM) are products parenteral for the one which results indispensable that they complete the requirements of established sterility. The radio sterilization result the method more recommend for the sterilization of the Acm deep drying, due to the contained first floor of humidity remnant that minimizes the formation of sub-product that they affect their properties. With the objective of proposing a good dose of irradiation for the sterilization, we were carried out a study of the radius sensibility so much of the product like of the polluting of greater frequency of isolation of the clean area of the CIM. The characterization of the radius sensibility of the different micro- organisms was determined by D 10 characteristic of each isolated strains. From the developed studies the Gram-positive rods endospore-forming were the most resistant strains at the deep drying, the radiations and they were of the greater frequency of apparition in the carried out isolations. We could conclude that utilizing a dose of 10 kGy it is possible to eliminate of the pollution more radio resistant, assuring the sterility required in the product, and without inducing effects under desire radiolytic in the same

  12. Effect of fermentation and sterilization on anthocyanins in blueberry.

    Science.gov (United States)

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  13. A search for sterile neutrinos with the latest cosmological observations

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lu; Zhang, Jing-Fei [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Zhang, Xin [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Peking University, Center for High Energy Physics, Beijing (China)

    2017-06-15

    We report the result of a search for sterile neutrinos with the latest cosmological observations. Both cases of massless and massive sterile neutrinos are considered in the ΛCDM cosmology. The cosmological observations used in this work include the Planck 2015 temperature and polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement data, the Planck Sunyaev-Zeldovich cluster counts data, the Planck lensing data, and the cosmic shear data. We find that the current observational data give a hint of the existence of massless sterile neutrino (as dark radiation) at the 1.44σ level, and the consideration of an extra massless sterile neutrino can indeed relieve the tension between observations and improve the cosmological fit. For the case of massive sterile neutrino, the observations give a rather tight upper limit on the mass, which implies that actually a massless sterile neutrino is more favored. Our result is consistent with the recent result of neutrino oscillation experiment done by the Daya Bay and MINOS collaborations, as well as the recent result of cosmic ray experiment done by the IceCube collaboration. (orig.)

  14. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  15. Sterile Neutrino Search in the NOvA Far Detector

    Energy Technology Data Exchange (ETDEWEB)

    Edayath, Sijith [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexandre [Cincinnati U.; Davies, Gavin [Indiana U.; Suter, Louise [Fermilab; Yang, Shaokai [Cincinnati U.

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvements that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.

  16. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  17. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  18. Sterilization of rotary NiTi instruments within endodontic sponges.

    Science.gov (United States)

    Chan, H W A; Tan, K H; Dashper, S G; Reynolds, E C; Parashos, P

    2015-08-17

    To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto horse blood agar and cultured aerobically and anaerobically to test sterility at purchase. Bacterial suspensions of Enterococcus faecalis, Porphyromonas gingivalis and Geobacillus stearothermophilus in BHI were used to contaminate sterile sponges and rotary NiTi instruments (with and without rubber stoppers) inserted into sponges. The various samples were autoclaved and then cultured aerobically and anaerobically. Success of sterilization was measured qualitatively as no growth. The experiment was repeated with clinically used rotary NiTi instruments (n = 512). All experiments were conducted in quadruplicate. No sponges on purchase had microbial growth when anaerobically cultured but some did when aerobically cultured. All autoclaved sponges and instruments (within or without sponges, and with or without rubber stoppers) were associated with no microbial growth. All nonautoclaved positive control samples showed microbial growth. Autoclaving was effective in the sterilization of sponges and endodontic instruments. Endodontic sponges should be autoclaved before clinical use. For clinical efficiency and cost-effectiveness, rotary NiTi instruments can be sterilized in endodontic sponges without removal of rubber stoppers. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. Radiating sterilization of the venom of snake

    International Nuclear Information System (INIS)

    Abiyev, H.A.; Topchiyeva, Sh.A.; Rustamov, V.R.

    2006-01-01

    Full text: Water solutions of venoms are unstable and they lose toxicity in some day. Snake venoms inactivate under action of some physical factors: the UV-irradiation, x-rays beams. The purpose of the present work was sterilization of venom Vipera lebetina obtusa under influence of small dozes γ-radiations. Object of research was integral venom of adult individuals. Transcaucasian viper, and also the water solutions of venom irradiated with small dozes scale of radiation. An irradiation of venom carried out to radioisotope installation 60NI. For experiment tests of dry venom, and also their water solutions have been taken. Water solutions of venom have been subjected -radiation up to dozes 1.35, 2.7, 4.05, 5.4 kGr simultaneously dry venom of vipers was exposed -radiation before absorption of a doze 5.4 kGr. In comparative aspect action scale of radiation on ultra-violet spectra of absorption of venom was studied. Ultra-violet spectra venom have been taken off on device Specord UV-VIS. In 12 months after an irradiation spectra of absorption of venom have been repeatedly taken off. In spectra irradiated dry and solutions of venom new maxima of absorption have been revealed in the field of 285 nm and 800 nm describing change of toxicity. It is shown, that the increase in absorption of a doze of radiation occurs decrease of intensity of strips of absorption reduction of intensity of absorption.It is revealed at 260 and 300 nm testifying to course of biochemical reactions of separate enzymes zootoxins. It is necessary to note, that at comparison of intensity of absorption of control samples of poison with irradiated up to dozes 1.35 kGr it has not been revealed essential changes. The subsequent increase in a doze scale of radiation up to 2.7, 4.05, 5.4 kGr promotes proportional reduction of intensity of the absorption, describing toxicity of snake venom. At repeated (later 12 months) measurement of the irradiated water solutions of venom are not revealed changes in

  20. A genetic male sterile line developed by molecular marker-assisted ...

    African Journals Online (AJOL)

    use

    2011-12-05

    Dec 5, 2011 ... of male sterility, and methods of crossing, backcrossing and selfing were applied to breed the male sterility to male fertile line of Chinese cabbage Y02. The SCAR marker syau-scr04 which linked to the male sterility gene Ms, was applied in the selection of Ms gene. The new male sterile line GMS4 with.

  1. 42 CFR 441.253 - Sterilization of a mentally competent individual aged 21 or older.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization of a mentally competent individual... LIMITS APPLICABLE TO SPECIFIC SERVICES Sterilizations § 441.253 Sterilization of a mentally competent individual aged 21 or older. FFP is available in expenditures for the sterilization of an individual only if...

  2. A genetic male sterile line developed by molecular marker-assisted ...

    African Journals Online (AJOL)

    A multiple allele inherited genetic male sterile line of Chinese cabbage 06s x 110 was used as the source of male sterility, and methods of crossing, backcrossing and selfing were applied to breed the male sterility to male fertile line of Chinese cabbage Y02. The SCAR marker syau-scr04 which linked to the male sterility ...

  3. Radiation sterilization of harmful algae in water

    International Nuclear Information System (INIS)

    Byung Chull An; Jae-Sung Kim; Seung Sik Lee; Shyamkumar Barampuram; Eun Mi Lee; Byung Yeoup Chung

    2007-01-01

    Complete text of publication follows. Objective: Drinking water, water used in food production and for irrigation, water for fish farming, waste water, surface water, and recreational water have been recently recognized as a vector for the transmission of harmful micro-organisms. The human and animal harmful algae is a waterborne risk to public health and economy because the algae are ubiquitous and persistent in water and wastewater, not completely removed by physical-chemical treatment processes, and relatively resistant to chemical disinfection. Gamma and electron beam radiation technology is of growing in the water industry since it was demonstrated that gamma and electron beam radiation is very effective against harmful algae. Materials and Methods: Harmful algae (Scenedesmus quadricauda(Turpin) Brebisson 1835 (AG10003), Chlorella vulgaris Beijerinck 1896 (AG30007) and Chlamydomonas sp. (AG10061)) were distributed from Korean collection for type cultures (KCTC). Strains were cultured aerobically in Allen's medium at 25□ and 300 umol/m2s for 1 week using bioreactor. We investigated the disinfection efficiency of harmful algae irradiated with gamma (0.05 to 10 kGy for 30 min) and electron beam (1 to 19 kGy for 5 sec) rays. Results and Conclusion: We investigated the disinfection efficiency of harmful algae irradiated with gamma and electron beam rays of 50 to 19000 Gy. We established the optimum sterilization condition which use the gamma and electron beam radiation. Gamma ray disinfected harmful algae at 400 Gy for 30 min. Also, electron beam disinfected at 1000 Gy for 5 sec. This alternative disinfection practice had powerful disinfection efficiency. Hence, the multi-barrier approach for drinking water treatment in which a combination of various disinfectants and filtration technologies are applied for removal and inactivation of different microbial pathogens will guarantee a lower risk of microbial contamination.

  4. Tubal anastomosis after previous sterilization: a systematic review.

    Science.gov (United States)

    van Seeters, Jacoba A H; Chua, Su Jen; Mol, Ben W J; Koks, Carolien A M

    2017-05-01

    Female sterilization is one of the most common contraceptive methods. A small number of women, however, opt for reversal of sterilization procedures after they experience regret. Procedures can be performed by laparotomy or laparoscopy, with or without robotic assistance. Another commonly utilized alternative is IVF. The choice between surgery and IVF is often influenced by reimbursement politics for that particular geographic location. We evaluated the fertility outcomes of different surgical methods available for the reversal of female sterilization, compared these to IVF and assessed the prognostic factors for success. Two search strategies were employed. Firstly, we searched for randomized and non-randomized clinical studies presenting fertility outcomes of sterilization reversal up to July 2016. Data on the following outcomes were collected: pregnancy rate, ectopic pregnancy rate, cost of the procedure and operative time. Eligible study designs included prospective or retrospective studies, randomized controlled trials, cohort studies, case-control studies and case series. No age restriction was applied. Exclusion criteria were patients suffering from tubal infertility from any other reason (e.g. infection, endometriosis and adhesions from previous surgery) and studies including sterilization reversal procedures were then evaluated: female age, BMI and duration and method of sterilization. Secondly, we searched for randomized and non-randomized clinical studies that compared reversal of sterilization to IVF and evaluated them for pregnancy outcomes and cost effectiveness. We included 37 studies that investigated a total of 10 689 women. No randomized controlled trials were found. Most studies were retrospective cohort studies of a moderate quality. The pooled pregnancy rate after sterilization reversal was 42-69%, with heterogeneity seen from the different methods utilized. The reported ectopic pregnancy rate was 4-8%. The only prognostic factor affecting the

  5. The impact of harm reduction programs and police interventions on the number of syringes collected from public spaces. A time series analysis in Barcelona, 2004-2014.

    Science.gov (United States)

    Espelt, A; Villalbí, J R; Bosque-Prous, M; Parés-Badell, O; Mari-Dell'Olmo, M; Brugal, M T

    2017-12-01

    To estimate the effect of opening two services for people who use drugs and three police interventions on the number of discarded syringes collected from public spaces in Barcelona between 2004 and 2014. We conducted an interrupted time-series analysis of the monthly number of syringes collected from public spaces during this period. The dependent variable was the number of syringes collected per month. The main independent variables were month and five dummy variables (the opening of two facilities with safe consumption rooms, and three police interventions). To examine which interventions affected the number of syringes collected, we performed an interrupted time-series analysis using a quasi-Poisson regression model, obtaining relative risks (RR) and 95% confidence intervals (CIs). The number of syringes collected per month in Barcelona decreased from 13,800 in 2004 to 1655 in 2014 after several interventions. For example, following the closure of an open drug scene in District A of the city, we observed a decreasing trend in the number of syringes collected [RR=0.88 (95% CI: 0.82-0.95)], but an increasing trend in the remaining districts [RR=1.11 (95% CI: 1.05-1.17) and 1.08 (95% CI: 0.99-1.18) for districts B and C, respectively]. Following the opening of a harm reduction facility in District C, we observed an initial increase in the number collected in this district [RR=2.72 (95% CI: 1.57-4.71)] and stabilization of the trend thereafter [RR=0.97 (95% CI: 0.91-1.03)]. The overall number of discarded syringes collected from public spaces has decreased consistently in parallel with a combination of police interventions and the opening of harm reduction facilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. "Absolute" sterility and "absolute" freedom from particle contamination.

    Science.gov (United States)

    Knapp, J Z

    1998-01-01

    Until the recent past, sterility of an injectable product was only discussed in absolute terms. Any description of sterility other than as an absolute could simply not be envisioned. While dealing in absolute yes/no statements is philosophically satisfying, these yes/no statements can't accommodate all real world scientific problems. Among these problems is the sterility problems faced in the mass production of injectable compounds. Many descriptions of procedures employed to achieve sterility in parenteral production batches were reported in the literature. The theoretical framework that could unite the widespread observations and practices into practical methodology was missing until recently. Production line control of the sterility of injectable products was essentially based on gut evaluations. The present achievement of rational, production line control of product sterility is based on the recognition that product sterility could not be simply regarded as a sharply edged yes/no affair. The present rational control is based on the fact that the sterility of a product is determined by the degree of contamination in the product prior to sterilization and to the parameters of the sterilization process. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. The essential laboratory measurements on which this conclusion was based is due to Pflug (1-3). He assembled a theoretical framework, based on experimental data, that characterizes the sterility achieved in an injectable product with a single number. The end result of the sterilization process is now described as a probabalistic reduction of the initial contamination. As in many disciplines, the ability to achieve an objective evaluation of this important attribute provided the basis for scientific analysis, improved control and thus improved production and reduced cost. An equivalent framework is essential for the communication and

  7. Multiple matings among glossina and the sterile male technique

    International Nuclear Information System (INIS)

    Pinhao, R.C.

    1980-01-01

    The fact that multiple matings are a common phenomenon among glossina turns the sterile male technique into a competition not between adult insects but between two types of sperm, and the proportion of females inseminated with the one or the other is given by the binomial (p+q)sup(n), where p is the percentage of normal males, q the percentage of sterile males and n the average number of matings per female. However, multiple matings cannot damage the effectiveness of the technique unless two conditions are present either separately or simultaneously: precocious death of the spermatozoa and reduced inseminating potential among the sterile males. Study of the factors which can alter the inseminating potential is thus important for those who wish to use the sterile male technique. These factors are of three kinds: factors connected with quality, with quantity and with availability. The first are associated with the nature and intensity of the alterations brought about in the spermatozoa by the sterilizing agent, the second with possible variations in the amount of sperm reaching the spermotheca, the third with the behaviour of the sterile males in the nature - that is, the question whether sterilization has a favourable or unfavourable influence on their chances of mating with wild females. The author describes his observations of the quantity of sperm produced by Glossina morsitans submorsitans males from the colony reared at the Institute for Tropical Hygiene and Medicine in Lisbon, compares them with the observations of other authors and discusses their practical significance. Specific research is suggested. Advantages from assessing the behaviour of colonies not by female productivity but by male inseminating potential, and appropriate laboratory techniques

  8. Prospects for radiation sterilization of medical products in Egypt

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1975-01-01

    The pharmaceutical industry in Egypt is continually expanding its activity and each year marks new accomplishments and additions which enable the companies to apply the most modern scientific means in the production of pharmaceutical preparations and consequently to improve their market potentialities. The certainty of expansion and the possibility of increasing exports of sterilized medical products, particularly to Arab and African countries, indicate a need for a gamma-sterilization plant. This technology permits the introduction of the latest practices with regard to used disposables, thus greatly reducing the chances of cross-contamination which usually results in serious complications enhanced by local environmental conditions. This paper reviews the current state and future prospects for radiation sterilization of medical products and biological tissues in connection with other related industrial radiation processings. Moreover, the paper reviews the Egyptian scientific and technical experience with irradiation facilities and the parameters underlying the choice of Egypt's first industrial gamma and electron-beam irradiators designed for more than a single-purpose use, with hygienic measures taken to avoid biological contamination of sterilized medical packages throughout the sterilization process. In addition, the paper deals with the policy set up for establishing the Egyptian National Centre for Radiation Technology with a view to introducing irradiation techniques in the sterilization of medical products, and to improving the properties and increasing the competitiveness of Egyptian fabrics. Apart from medical sterilization, certain industrial processes have been mentioned to show how a multi-purpose irradiation facility may be utilized in a developing country to justify significantly the large investment required. (author)

  9. Temperature Effects on Free Radicals in Gamma-sterilized Beef

    Science.gov (United States)

    Pramanik, S. I.; Jahan, M. S.

    1999-11-01

    Gamma irradiation has become the method of choice for sterilizing frozen meat and their products to reduce levels of food-borne pathogens and to extend shelf life. In this report we have employed ESR technique for detection of free radicals in sterilized and non-sterilized dry beef without bone. We have also determined the heating effects on free radicals at temperatures 176^°C and 250^°C. Meat samples were dried in a food dehydrator at 60^°C and were packaged in dry N_2. They were then sterilized by γ-irradiation (2.5 MRad), ground into powder, and placed in ESR sample tubes. Non-sterilized powder samples were used as control. While all powder samples, sterilized or not, produced a broad single line in the ESR spectra with (Δ H_pp ~ 9 G) and g = 2.013, the radical concentration in the sterilized samples increased by a factor of five. Heat treatment at 176^°C produced similar radicals. But, when samples were heated 250^°C different radical species were formed which are characterized by narrow width (Δ H_pp ~ 6 G) and lower g-value (g =2.010). In contrast with previous work, where free radicals in chicken bones were reduced by heating [1], we observed an increase in concentration. Results of structural analyses of the radicals will be presented. Ref.[1]: Radiat. Phys. Chem., 49, 477-481, 1997. Work supported by Grants from the University of Memphis

  10. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study.

    Science.gov (United States)

    Venkatasubramanian, R; Das, U M; Bhatnagar, S

    2010-01-01

    Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde) and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  11. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    Science.gov (United States)

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  12. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venkatasubramanian R

    2010-03-01

    Full Text Available Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  13. Vasectomy occlusion techniques for male sterilization.

    Science.gov (United States)

    Cook, L A; Vliet, H; Pun, A; Gallo, M F

    2004-01-01

    Vasectomy is an increasingly popular and effective family planning method. A variety of vasectomy techniques are used worldwide including various vas occlusion techniques (excision and ligation, thermal or electrocautery, and mechanical and chemical occlusion methods), vas irrigation and fascial interposition. Vasectomy guidelines largely rely on information from observational studies. Ideally, the choice of vasectomy techniques should be based on the best available evidence from randomized controlled trials. The objective of this review was to compare the effectiveness, safety, acceptability and costs of vasectomy techniques for male sterilization. We searched the computerized databases the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Popline and LILACS. In addition, we searched the reference lists of relevant articles and book chapters. We included randomized controlled trials and controlled clinical trials comparing vasectomy techniques. We assessed all titles and abstracts located in the literature searches and two reviewers independently extracted articles identified for inclusion. Data were presented in the text of the review. Outcome measures include contraceptive efficacy, safety, discontinuation, and acceptability. Two trials compared vas occlusion with clips versus a conventional vasectomy technique; both were of poor quality. Neither trial found a difference between the two groups with regard to the primary outcome of failure to reach azoospermia. Four trials examined vas irrigation: three compared water irrigation with no irrigation and one compared water irrigation with euflavine. All of the trials were of poor quality. None of the trials found a significant difference between the groups with respect to the primary outcome of time to azoospermia. However, one trial found that the median number of ejaculations to azoospermia was significantly lower in the euflavine group compared to the water irrigation group. The one trial

  14. Formation and removal of apical vapor lock during syringe irrigation: a combined experimental and Computational Fluid Dynamics approach.

    Science.gov (United States)

    Boutsioukis, C; Kastrinakis, E; Lambrianidis, T; Verhaagen, B; Versluis, M; van der Sluis, L W M

    2014-02-01

    (i) To evaluate the effect of needle type and insertion depth, root canal size and irrigant flow rate on the entrapment of air bubbles in the apical part of a root canal (apical vapor lock) during syringe irrigation using experiments and a Computational Fluid Dynamics (CFD) model, (ii) to investigate whether the irrigant contact angle affects bubble entrapment, (iii) to examine if an established vapor lock can be removed by syringe irrigation. Bubble entrapment during irrigation of straight artificial root canals of size 35 or 50 was evaluated by real-time visualizations. The irrigant was delivered by a closed-ended or an open-ended needle positioned at 1 or 3 mm short of working length (WL) and at a flow rate of 0.033-0.260 mL s(-1) . Results were analysed by nonparametric tests at 0.05 significance. Selected cases were also simulated by a two-phase CFD model. A vapor lock was observed in 48% of the cases investigated experimentally. Increasing the apical size, using an open-ended needle, positioning the needle closer to WL and delivering the irrigant at higher flow rate resulted in significantly smaller vapor lock. An increased contact angle resulted in the entrapment of a larger bubble when a low flow rate was used. Both brief insertion of the needle to WL whilst irrigating at a flow rate of 0.083 mL s(-1) and delivering the irrigant at 0.260 mL s(-1) without changing the needle position were capable of removing an established vapor lock. Apical vapor lock may occur under certain conditions, but appears to be easily prevented or removed by syringe irrigation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  15. Effects of an Intensive Street-Level Police Intervention on Syringe Exchange Program Use in Philadelphia, Pa

    Science.gov (United States)

    Davis, Corey S.; Burris, Scott; Kraut-Becher, Julie; Lynch, Kevin G.; Metzger, David

    2005-01-01

    Repeated measurements and mixed-effects models were used to analyze the effects of an intensive long-term street-level police intervention on syringe exchange program use. Utilization data for 9 months before and after the beginning of the intervention were analyzed. Use fell across all categories and time periods studied, with significant declines in use among total participants, male participants, and Black participants. Declines in use among Black and male participants were much more pronounced than decreases among White and female participants. PMID:15671455

  16. A preliminary evaluation of a reusable digital sterilization indicator prototype.

    Science.gov (United States)

    Puttaiah, R; Griggs, J; D'Onofrio, M

    2014-09-01

    Sterilization of critical and semicritical instruments used in patient care must undergo a terminal process of sterilization. Use of chemical and physical indicators are important in providing information on the sterilizer's performance during each cycle. Regular and periodic monitoring of sterilizers using biological indicators is necessary in periodically validating performance of sterilizers. Data loggers or independent digital parametric indicators are innovative devices that provide more information than various classes chemical indicators. In this study we evaluated a prototype of an independent digital parametric indicator's use in autoclaves. The purpose of this study was to evaluate the performance of an independent digital indicator/data logger prototype (DS1922F) that could be used for multiple cycles within an autoclave.MG Materials and methods: Three batches of the DS1922F (150 samples) were used in this study that was conducted in a series. The first batch was challenged with 300 sterilization cycles within an autoclave and the data loggers evaluated to study failures and the reason for failure, make corrections and improve the prototype design. After changes made based on studying the first batch, the second batch of the prototype (150 samples) were challenged once again with 300 sterilization cycles within an autoclave and failure studied again in further improvement of the prototype. The final batch (3rd batch) of the prototype (150 samples) was challenged again but with 600 cycles to see how long they would last. Kaplan-Meier survival analysis analyses of all three batches was conducted (α = 0.05) and failed samples qualitatively studied in understanding the variables involved in the failure of the prototype, and in improving quality. Each tested batch provided crucial information on device failure and helped in improvement of the prototype. Mean lifetime survival of the final batch (Batch 3) of prototype was 498 (480, 516) sterilization cycles

  17. Developing transgenic Anopheles mosquitoes for the sterile insect technique.

    Science.gov (United States)

    Nolan, Tony; Papathanos, Philippos; Windbichler, Nikolai; Magnusson, Kalle; Benton, Jason; Catteruccia, Flaminia; Crisanti, Andrea

    2011-01-01

    In the last 10 years the availability of the genome sequence of Anopheles gambiae and the development of a transgenic technology for several species of Anopheles mosquitoes have, in combination, helped in enabling us to gain several insights into the biology of these mosquitoes that is relevant to their capacity as vectors of the malaria parasite. While this information is anticipated to inform many novel vector control strategies, the technique most likely to benefit in the near future from the availability of a reliable transgenic technology is the sterile insect technique (SIT), which relies on releasing large numbers of sterile insects to compete for mates in the wild, leading to population suppression. Although SIT has been proven to work reliably for many insects, the construction of suitable strains, and induction of sterility, has until now been a laborious process, combining classical genetics with radiation-induced sterility. Using transgenesis to create strains of Anopheles suitable for SIT could potentially offer several advantages over current approaches, in that the basic design of transgenic constructs designed for other insects should be rapidly transferable to mosquitoes, and induction of sterility as a product of the transgenic modification could obviate the requirement for radiation and its associated deleterious effects. In this paper the progress of different transgenic approaches in constructing tools for SIT will be reviewed.

  18. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    International Nuclear Information System (INIS)

    Huang, Junting

    2015-01-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states v e , v μ and v τ . In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ 24 in the range of 10 -2 eV 2 < Δm 43 2 < 1 eV 2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  19. Search for heavy sterile neutrinos in trileptons at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Claudio O. [Univ. Tecnica Federico Santa Maria, Valparaiso (Chile). CCTVal y Dept. of Physics; Kim, C.S. [Yonsei Univ., Seoul (Korea, Republic of). Dept. of Physics and IPAP; Wang, Kechen [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Chinese Academy of Sciences, Beijing (China). Center for Future High Energy Physics

    2017-03-15

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W{sup ±}→e{sup ±}e{sup ±}μ{sup -+}ν and μ{sup ±}μ{sup ±}e{sup -+}ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m{sub N}=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb{sup -1}, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U{sub Ne} vertical stroke {sup 2}∝ vertical stroke U{sub Nμ} vertical stroke {sup 2}∝10{sup -6}, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10{sup -5}.

  20. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments

    Directory of Open Access Journals (Sweden)

    Tamara Carolina de Camargo

    Full Text Available ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled and positive control (30 filter paper supports, unsterilized, subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument.