WorldWideScience

Sample records for single-specimen test measurement

  1. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  2. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  3. C.O.D. toughness testing of medium strength steel as a preliminary development for single specimen J integral toughness tests of SA533-B steel

    International Nuclear Information System (INIS)

    Dean, P.; Tait, R.B.; Garrett, G.G.

    1981-10-01

    The primary purpose of this project is to set up a test facility and to develop the necessary expertise to enable reliable elasto-plastic fracture toughness tests to be performed. Initially, tests are to be conducted on material similar to that used in the Koeberg pressure vessel walls, with the ultimate goal of performing single specimen J integral tests on the pressure vessel steel itself to determine through-thickness toughness variations. The project will comprise a number of stages, each one necessary for the development of the techniques used in J integral testing. These include: (i) development of an appropriate specimen design, of suitable size and shape that is applicable to both crack opening displacement (C.O.D.) and J integral tests; (ii) development, testing and calibration of the necessary associated mechanical and electrical equipment (e.g. clip gauge, amplifiers, interface unit, etc.), with (iii) an estimation of the probable errors and noise levels with a view to their elimantion, leading to (iv) perfection of the sensitivity and reproducibility of, firstly, the multiple specimen C.O.D. technique and, secondly, the multiple specimen J integral techniques. (v) Based on the above techniques, development of the single specimen J integral test method incorporating development of a computerised testing procedure. All the above procedure is to be conducted on similar, but non-Koeberg pressure vessel material ('ROQ Tough'). (vi) Finally, development and testing of both multiple specimen and single specimen J integral tests on actual SA533B material and an investigation of the through thickness toughness and fatigue crack propagation behaviour

  4. Study of Biological Pigments by Single Specimen Derivative Spectrophotometry

    Science.gov (United States)

    Goldstein, Jack M.

    1970-01-01

    The single specimen derivative (SSD) method provides an absolute absorption spectrum of a substance in the absence of a suitable reference. Both a reference and a measuring monochromatic beam pass through a single sample, and the specimen itself acts as its own reference. The two monochromatic beams maintain a fixed wavelength difference upon scanning, and the difference in absorbance of the two beams is determined. Thus, the resulting spectrum represents the first derivative of the conventional type absorption spectrum. Tissues and cell fractions have been examined at room and liquid N2 temperature and chromophoric molecules such as the mitochondrial cytochromes and blood pigments have been detectable in low concentrations. In the case of isolated cellular components, the observed effects of substrates and inhibitors confirm similar studies by conventional spectrophotometry. The extension of the SSD concept to the microscopic level has permitted the study of the tissue compartmentalization and function of cytochromes and other pigments within layered tissue. PMID:4392452

  5. Reconstruction of the PETM onset from single specimen analyses of foraminiferal stable isotopes at Medford, NJ

    Science.gov (United States)

    Makarova, M.; Miller, K. G.; Wright, J. D.

    2017-12-01

    The Paleocene-Eocene transition ( 56 Ma) is marked by a global temperature increase of 4-8°C and the carbon isotope excursion (CIE) found ubiquitously in marine and terrestrial realms. However, the mechanisms of warming and overall changes in the ocean-atmosphere system during the Paleocene-Eocene thermal maximum (PETM) are uncertain. The timing of the PETM onset has been debated suggested by various studies between years to thousands of years and therefore is of particular interest to ascertain the trigger mechanism. One way to resolve this is to study thick cores on the continental margins that have higher sedimentation rates and thus resolution. Stratigraphically more complete in regard to the CIE onset marine PETM sections are found along the U.S. mid-Atlantic margin, New Jersey coastal plain (35-40°N paleolatitude). We present new carbon and oxygen isotopic data of planktonic and benthic foraminifera from the Medford 3A core, drilled on the New Jersey coastal plain in Summer 2016. Medford is the most proximal among the New Jersey coastal plain sites. The Medford 3A core has recovered 4 ft (1.2 m) of the Marlboro Formation, unit that contains the CIE "core" with low stable δ13C values and CIE recovery in other New Jersey cores. The top of the Marlboro Formation is truncated at Medford 3A, but the base is conformable with the underlaying Vincentown Formation. The sharp δ13C decrease appears within the Vincentown/Marlboro transitional lithological interval 1.5 ft (0.5 m) thick allowing a detailed study of the PETM onset. The Medford 3A core recovered sufficient well-preserved foraminifera to establish isotopic changes across the PETM onset. We measure δ13C and δ18O in single specimens of surface dwellers (Morozovella, Acarinina), thermocline dwellers (Subbotina), and benthic foraminifera (Anomalinoides, Cibicidoides) at high resolution to understand the nature of the PETM onset. We compliment previously published single specimen isotopic records from the

  6. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  7. Thermal Testing Measurements Report

    Energy Technology Data Exchange (ETDEWEB)

    R. Wagner

    2002-09-26

    The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure

  8. Measuring Test Measurement Error: A General Approach

    Science.gov (United States)

    Boyd, Donald; Lankford, Hamilton; Loeb, Susanna; Wyckoff, James

    2013-01-01

    Test-based accountability as well as value-added asessments and much experimental and quasi-experimental research in education rely on achievement tests to measure student skills and knowledge. Yet, we know little regarding fundamental properties of these tests, an important example being the extent of measurement error and its implications for…

  9. Determining fracture-mechanics characteristics of reactor pressure vessel steels applying the single-specimen compliance method and correlations to notch impact energy

    International Nuclear Information System (INIS)

    Bergmann, U.; Boehmert, J.; Viehrig, H.W.

    1995-03-01

    Fracture-mechanics crack resistance parameters based on the J integral are useful to describe the failure behaviour of high-toughness reactor pressure vessel steels. This paper presents methodical results concerning the estimation of crack growth resistance curves of precracked and sidegrooved Charpy sized 3-PB specimens by using the single specimen compliance method. Crack initiation toughness values are estimated on the basis of the measured stretch zone with and as a technical equivalent values from the crack resistant curves described by a polynom. The wide range of toughness or strength of the investigated steels allows to investigate relationships known from the literature between the upper shelf Charpy-V notch energy and the crack growth resistance behaviour. The relationships provide acceptable technical approaches, but they can only insufficiently describe the physical meaning. (orig.) [de

  10. Test limits using correlated measurements

    NARCIS (Netherlands)

    Albers, Willem/Wim; Arts, G.R.J.; Kallenberg, W.C.M.

    1998-01-01

    In the standard model for inspection of manufactured parts measurements of the characteristic of interest are subject to, typically small, measurement errors. This leads to test limits which are slightly more strict than the corresponding specification limits. Quite often, however, such direct

  11. Conformance Testing: Measurement Decision Rules

    Science.gov (United States)

    Mimbs, Scott M.

    2010-01-01

    The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to provide assurance to the customer that end products meet specifications. Measuring devices, often called measuring and test equipment (MTE), are used to provide the evidence of product conformity to specified requirements. Unfortunately, processes that employ MTE can become a weak link to the overall QMS if proper attention is not given to the measurement process design, capability, and implementation. Documented "decision rules" establish the requirements to ensure measurement processes provide the measurement data that supports the needs of the QMS. Measurement data are used to make the decisions that impact all areas of technology. Whether measurements support research, design, production, or maintenance, ensuring the data supports the decision is crucial. Measurement data quality can be critical to the resulting consequences of measurement-based decisions. Historically, most industries required simplistic, one-size-fits-all decision rules for measurements. One-size-fits-all rules in some cases are not rigorous enough to provide adequate measurement results, while in other cases are overly conservative and too costly to implement. Ideally, decision rules should be rigorous enough to match the criticality of the parameter being measured, while being flexible enough to be cost effective. The goal of a decision rule is to ensure that measurement processes provide data with a sufficient level of quality to support the decisions being made - no more, no less. This paper discusses the basic concepts of providing measurement-based evidence that end products meet specifications. Although relevant to all measurement-based conformance tests, the target audience is the MTE end-user, which is anyone using MTE other than calibration service providers. Topics include measurement fundamentals, the associated decision risks, verifying conformance to specifications, and basic measurement

  12. Strain measurement based battery testing

    Science.gov (United States)

    Xu, Jeff Qiang; Steiber, Joe; Wall, Craig M.; Smith, Robert; Ng, Cheuk

    2017-05-23

    A method and system for strain-based estimation of the state of health of a battery, from an initial state to an aged state, is provided. A strain gauge is applied to the battery. A first strain measurement is performed on the battery, using the strain gauge, at a selected charge capacity of the battery and at the initial state of the battery. A second strain measurement is performed on the battery, using the strain gauge, at the selected charge capacity of the battery and at the aged state of the battery. The capacity degradation of the battery is estimated as the difference between the first and second strain measurements divided by the first strain measurement.

  13. General measure of Enterprising Tendency test

    OpenAIRE

    Caird, Sally

    2013-01-01

    The General measure of Enterprising Tendency test (GET2) is a measure of enterprising tendency developed for educational use and self assessment. It measures five entrepreneurial attributes, namely Need for achievement, Need for Autonomy, Creative Tendency, Calculated Risk taking and Locus of control, providing interpretation for this enterprising attributes. Since 1998 there has been considerable worldwide interest in the test of General Enterprising Tendency (GET test) developed and tested ...

  14. Testing a measure of cyberloafing.

    Science.gov (United States)

    Blau, Gary; Yang, Yang; Ward-Cook, Kory

    2006-01-01

    Using a primary sample of medical technologists (MTs) and a second validation sample, the results of this study showed initial support for a three-factor measure of cyberloafing. The three scales were labeled browsing-related, non-work-related e-mail, and interactive cyberloafing. MTs who perceived unfair treatment in their organization (i.e., lower organizational justice) were more likely to exhibit all three types of cyberloafing. MTs who did not care as much about punctuality and attendance (i.e., higher time abuse) were more likely to display browsing-related and non-work-related e-mail cyberloafing. Finally, MTs who perceived an inability to control their work environment (i.e., powerlessness) were more likely to display interactive cyberloafing. Study limitations and suggestions for future research are discussed.

  15. Validation of measured friction by process tests

    DEFF Research Database (Denmark)

    Eriksen, Morten; Henningsen, Poul; Tan, Xincai

    The objective of sub-task 3.3 is to evaluate under actual process conditions the friction formulations determined by simulative testing. As regards task 3.3 the following tests have been used according to the original project plan: 1. standard ring test and 2. double cup extrusion test. The task...... has, however, been extended to include a number of new developed process tests: 3. forward rod extrusion test, 4. special ring test at low normal pressure, 5. spike test (especially developed for warm and hot forging). Validation of the measured friction values in cold forming from sub-task 3.1 has...

  16. Measurement of children's creativity by tests

    Directory of Open Access Journals (Sweden)

    Maksić Slavica B.

    2003-01-01

    Full Text Available After over a 50-year permanent development of tests designed to measure creativity and the results they produced, a question is raised if creativity can be measured by tests at all. A special problem are procedures for measuring creative potential in younger children because children, unlike adults, do not possess creative products that are a single reliable evidence of creativity in the real world. The paper considers test reliability and validity in measuring creativity as well as the dilemma: how much justifiable it is to measure children's creativity by tests if it is not clear what they measure and if there is not a significant relationship between creativity scores and creativity in life. Unsatisfactory creativity test reliability and validity does not mean those tests should be given up the majority of researchers agree. Of the tests of creativity administered in work with the young, the status of Urban-Jellen Test of Creative Thinking - Drawing Production (TCT-DP is given prominence due to the fact that over the past ten years or so it has been used in a larger number of studies as well as in some studies carried out in this country. In TCT-DP scoring is not based on statistical uncommonness of the figures produced but on a number of criteria derived from Gestalt psychology. The factor analyses of the defined criteria of creativity, applied on samples in various settings yielded that the test contains an essential factor of creativity "novelty".

  17. Standardized Testing of Phasor Measurement Units

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Kenneth E.; Faris, Anthony J.; Hauer, John F.

    2006-05-31

    This paper describes a set of tests used to determine Phasor Measurement Unit (PMU) measurement characteristics under steady state and dynamic conditions. The methodology is repeatable, comparable among test facilities, and can be performed at any facility with commonly available relay and standard test equipment. The methodology is based upon using test signals that are mathematically generated from a signal model and played into the PMU with precise GPS synchronization. Timing flags included with the test signal provide correlate the test signals and the PMU output. This allows accurate comparison of the phasor model with the value estimated by the PMU for accurate performance analysis. The timing flags also facilitate programmed plot and report generation.

  18. Phishing IQ Tests Measure Fear, Not Ability

    Science.gov (United States)

    Anandpara, Vivek; Dingman, Andrew; Jakobsson, Markus; Liu, Debin; Roinestad, Heather

    We argue that phishing IQ tests fail to measure susceptibility to phishing attacks. We conducted a study where 40 subjects were asked to answer a selection of questions from existing phishing IQ tests in which we varied the portion (from 25% to 100%) of the questions that corresponded to phishing emails. We did not find any correlation between the actual number of phishing emails and the number of emails that the subjects indicated were phishing. Therefore, the tests did not measure the ability of the subjects. To further confirm this, we exposed all the subjects to existing phishing education after they had taken the test, after which each subject was asked to take a second phishing test, with the same design as the first one, but with different questions. The number of stimuli that were indicated as being phishing in the second test was, again, independent of the actual number of phishing stimuli in the test. However, a substantially larger portion of stimuli was indicated as being phishing in the second test, suggesting that the only measurable effect of the phishing education (from the point of view of the phishing IQ test) was an increased concern—not an increased ability.

  19. Direct friction measurement in draw bead testing

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2005-01-01

    have been reported in literature. A major drawback in all these studies is that friction is not directly measured, but requires repeated measurements of the drawing force with and without relative sliding between the draw beads and the sheet material. This implies two tests with a fixed draw bead tool......-in piezoelectric torque transducer. This technique results in a very sensitive measurement of friction, which furthermore enables recording of lubricant film breakdown as function of drawing distance. The proposed test is validated in an experimental investigation of the influence of lubricant viscosity...

  20. High-voltage test and measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hauschild, Wolfgang; Lemke, Eberhard

    2014-04-01

    Reflects the unit of both HV testing and measuring technique. Intended as an ''application guide'' for the relevant IEC standards. Refers also to future trends in HV testing and measuring technique. With numerous illustrations. It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  1. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (2008) to detect whether the widely used class of Residual Income based performa......Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (2008) to detect whether the widely used class of Residual Income based...... performance measures —such as Economic Value Added (EVA)— is distorted, leading to unintended agent behavior. The paper uses a difference-in-differences approach to account for changes in economic circumstances and the self-selection of firms using EVA. Our findings indicate that EVA is a distorted...... performance measure that elicits the gaming response....

  2. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    2015-01-01

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (Review of Economics and Statistics, 90, 428-441) to detect whether the widely...... used class of residual income-based performance measures-such as economic value added (EVA)-is distorted, leading to unintended agent behavior. The paper uses a difference-in-differences approach to account for changes in economic circumstances and the self-selection of firms using EVA. Our findings...... indicate that EVA is a distorted performance measure that elicits the gaming response....

  3. Work zone performance measures pilot test.

    Science.gov (United States)

    2011-04-01

    Currently, a well-defined and validated set of metrics to use in monitoring work zone performance do not : exist. This pilot test was conducted to assist state DOTs in identifying what work zone performance : measures can and should be targeted, what...

  4. Acoustic emission measurements during impacts tests for determining ductile fracture data; Ermittlung zaehbruchmechanischer Kennwerte unter schlagartiger Belastung mittels Schallemission

    Energy Technology Data Exchange (ETDEWEB)

    Richter, H.

    2000-09-01

    The document reports work for further development of methods and tests to obtain better information on the crack initiation toughness (J{sub id}) under impact loading conditions, by acoustic emission measurements. The applicability of the acoustic emission tests for the given purpose was proven by instrumented Charpy tests using modified ISO-V specimens. The physical crack initiation toughness served as the reference value for reliable evaluation of the characteristic data obtained. This reference value is derived from the crack resistance curve determined by the multi-specimen cleavage fracture method combined with data from measurements of the stretching zone width. Verification of the acoustic emission-defined initiation value included a variety of tests, as e.g. additional dynamic single-specimen methods (L-COD, magnetic emission), and supplementary tests (D3PB, pendulum impact testing machine). The test materials are various steels with different strength/toughness properties. (orig./CB) [German] Gegenstand der vorliegenden Arbeit ist die Weiterentwicklung von Verfahren zur Ermittlung der Risseinleitungszaehigkeit (J{sub id}) unter schlagartigen Belastungsbedingungen. Als Indikationsmethode fuer die duktile Rissinitiierung wurde die Messung der unter Beanspruchung im Werkstoff freigesetzten elastischen Energie - der Schallemission (SE) - genutzt. Die Eignung dieser Methode wurde im instrumentierten Kerbschlagbiegeversuch an modifizierten ISO-V-Proben geprueft. Als zuverlaessige Basis fuer eine Beurteilung der damit bestimmten Kennwerte wird die physikalische Rissinitiierungszaehigkeit angesehen. Dieser Referenzwert wird in Verbindung mit der Messung der Stretchzonenbreite aus der nach der Mehrproben-Spaltbruchmethode ermittelten Risswiderstandskurve gewonnen. Die Bestimmung des SE-definierten Initiierungswertes wurde mit zusaetzlichen dynamischen Einprobenverfahren (Laser-COD, magnetische Emission) und ergaenzenden Versuchsanordnungen (invertiertes

  5. Measuring Cardiac Output during Cardiopulmonary Exercise Testing.

    Science.gov (United States)

    Vignati, Carlo; Cattadori, Gaia

    2017-07-01

    Cardiac output is a key parameter in the assessment of cardiac function, and its measurement is fundamental to the diagnosis, treatment, and prognostic evaluation of all heart diseases. Until recently, cardiac output determination during exercise had been only possible through invasive methods, which were not practical in the clinical setting. Because [Formula: see text]o 2 is cardiac output times arteriovenous content difference, evaluation of cardiac output is usually included in its measurement. Because of the difficulty of directly measuring peak exercise cardiac output, indirect surrogate parameters have been proposed, but with only modest clinical usefulness. Direct measurement of cardiac output can now be made by several noninvasive techniques, such as rebreathing inert gases, impedance cardiology, thoracic bioreactance, estimated continuous cardiac output technology, and transthoracic echocardiography coupled to cardiopulmonary exercise testing, which allow more definitive results and better understanding of the underlying physiopathology.

  6. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  7. Educational Testing as an Accountability Measure

    DEFF Research Database (Denmark)

    Ydesen, Christian

    2013-01-01

    for continued use in contemporary educational settings. Accountability measures and practices serve as a way to govern schools; by analysing the history of accountability as the concept has been practised in the education sphere, the article will discuss both pros and cons of such a methodology, particularly......This article reveals perspectives based on experiences from twentieth-century Danish educational history by outlining contemporary, test-based accountability regime characteristics and their implications for education policy. The article introduces one such characteristic, followed by an empirical...... analysis of the origins and impacts of test-based accountability measures applying both top-down and bottom-up perspectives. These historical perspectives offer the opportunity to gain a fuller understanding of this contemporary accountability concept and its potential, appeal, and implications...

  8. Test Beam Measurements on Picosec Gaseous Detector.

    CERN Document Server

    Sohl, Lukas

    2017-01-01

    In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data.

  9. Testing substellar models with dynamical mass measurements

    Directory of Open Access Journals (Sweden)

    Liu M.C.

    2011-07-01

    Full Text Available We have been using Keck laser guide star adaptive optics to monitor the orbits of ultracool binaries, providing dynamical masses at lower luminosities and temperatures than previously available and enabling strong tests of theoretical models. We have identified three specific problems with theory: (1 We find that model color–magnitude diagrams cannot be reliably used to infer masses as they do not accurately reproduce the colors of ultracool dwarfs of known mass. (2 Effective temperatures inferred from evolutionary model radii are typically inconsistent with temperatures derived from fitting atmospheric models to observed spectra by 100–300 K. (3 For the only known pair of field brown dwarfs with a precise mass (3% and age determination (≈25%, the measured luminosities are ~2–3× higher than predicted by model cooling rates (i.e., masses inferred from Lbol and age are 20–30% larger than measured. To make progress in understanding the observed discrepancies, more mass measurements spanning a wide range of luminosity, temperature, and age are needed, along with more accurate age determinations (e.g., via asteroseismology for primary stars with brown dwarf binary companions. Also, resolved optical and infrared spectroscopy are needed to measure lithium depletion and to characterize the atmospheres of binary components in order to better assess model deficiencies.

  10. Acoustic emission measurement during instrumented impact tests

    International Nuclear Information System (INIS)

    Crostack, H.A.; Engelhardt, A.H.

    1983-01-01

    Results of instrumented impact tests are discussed. On the one hand the development of the loading process at the hammer tup was recorded by means of a piezoelectric transducer. This instrumentation supplied a better representation of the load versus time than the conventional strain gauges. On the other hand the different types of acoustic emission occurring during a test could be separated. The acoustic emission released at the impact of the hammer onto the specimen is of lower frequency and its spectrum is strongly decreasing with increasing frequency. Plastic deformation also emits signals of lower frequency that are of quasi-continuous character. Both signal types can be discriminated by filtering. As a consequence typical burst signal were received afterwards that can be correlated with crack propagation. Their spectra exhibit considerable portions up to about 1.9 MHz. The development in time of the burst signals points to the kind of crack propagation resp. its sequence of appearance. However, definitive comparison between load and acoustic emission should become possible, only when the disadvantages of the common load measurement can be reduced, e.g. by determining the load directly at the specimen instead of the hammer tup

  11. Measuring Test Case Similarity to Support Test Suite Understanding

    NARCIS (Netherlands)

    Greiler, M.S.; Van Deursen, A.; Zaidman, A.E.

    2012-01-01

    Preprint of paper published in: TOOLS 2012 - Proceedings of the 50th International Conference, Prague, Czech Republic, May 29-31, 2012; doi:10.1007/978-3-642-30561-0_8 In order to support test suite understanding, we investigate whether we can automatically derive relations between test cases. In

  12. Measuring test coverage of SoA services

    NARCIS (Netherlands)

    Sneed, Harry M.; Verhoef, Chris

    2015-01-01

    One of the challenges of testing in a SoA environment is that testers do not have access to the source code of the services they are testing. Therefore they are not able to measure test coverage at the code level, as is done in conventional white-box testing. They are compelled to measure test

  13. What do educational test scores really measure?

    DEFF Research Database (Denmark)

    McIntosh, James; D. Munk, Martin

    Latent class Poisson count models are used to analyze a sample of Danish test score results from a cohort of individuals born in 1954-55 and tested in 1968. The procedure takes account of unobservable effects as well as excessive zeros in the data. The bulk of unobservable effects are uncorrelate...

  14. A test for ordinal measurement invariance

    NARCIS (Netherlands)

    Ligtvoet, R.; Millsap, R.E.; Bolt, D.M.; van der Ark, L.A.; Wang, W.-C.

    2015-01-01

    One problem with the analysis of measurement invariance is the reliance of the analysis on having a parametric model that accurately describes the data. In this paper an ordinal version of the property of measurement invariance is proposed, which relies only on nonparametric restrictions. This

  15. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  16. Mercury flow tests (first report). Wall friction factor measurement tests and future tests plan

    International Nuclear Information System (INIS)

    Kaminaga, Masanori; Kinoshita, Hidetaka; Haga, Katsuhiro; Hino, Ryutaro; Sudo, Yukio

    1999-07-01

    In the neutron science project at JAERI, we plan to inject a pulsed proton beam of a maximum power of 5 MW from a high intense proton accelerator into a mercury target in order to produce high energy neutrons of a magnitude of ten times or more than existing facilities. The neutrons produced by the facility will be utilized for advanced field of science such as the life sciences etc. An urgent issue in order to accomplish this project is the establishment of mercury target technology. With this in mind, a mercury experimental loop with the capacity to circulate mercury up to 15 L/min was constructed to perform thermal hydraulic tests, component tests and erosion characteristic tests. A measurement of the wall friction factor was carried out as a first step of the mercury flow tests, while testing the characteristic of components installed in the mercury loop. This report presents an outline of the mercury loop and experimental results of the wall friction factor measurement. From the wall friction factor measurement, it was made clear that the wettability of the mercury was improved with an increase of the loop operation time and at the same time the wall friction factors were increased. The measured wall friction factors were much lower than the values calculated by the Blasius equation at the beginning of the loop operation because of wall slip caused by a non-wetted condition. They agreed well with the values calculated by the Blasius equation within a deviation of 10% when the sum of the operation time increased more than 11 hours. This report also introduces technical problems with a mercury circulation and future tests plan indispensable for the development of the mercury target. (author)

  17. Compensation of Unavailable Test Frequencies During Immunity Measurements

    Science.gov (United States)

    Gronwald, F.; Kebel, R.; Stadtler, T.

    2012-05-01

    Radiated immunity tests usually are performed in shielded test environments, such as anechoic chambers, GTEM-cells, and mode stirred chambers, for example. Then, if testing is performed in the frequency domain, the corresponding EMC-standards often specify test frequencies that have to be used. These requirements may become incompatible in case of large test objects, such as passenger aircraft, that cannot be placed in shielded test environments but only can be tested in open environments where, for regulatory reasons, not all required test frequencies can be applied. In this contribution it is investigated whether incomplete test procedures due to unavailable test frequencies can be compensated by alternative measurement setups.

  18. Test device for measuring permeability of a barrier material

    Science.gov (United States)

    Reese, Matthew; Dameron, Arrelaine; Kempe, Michael

    2014-03-04

    A test device for measuring permeability of a barrier material. An exemplary device comprises a test card having a thin-film conductor-pattern formed thereon and an edge seal which seals the test card to the barrier material. Another exemplary embodiment is an electrical calcium test device comprising: a test card an impermeable spacer, an edge seal which seals the test card to the spacer and an edge seal which seals the spacer to the barrier material.

  19. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  20. Reducing measurement errors during functional capacity tests in elders.

    Science.gov (United States)

    da Silva, Mariane Eichendorf; Orssatto, Lucas Bet da Rosa; Bezerra, Ewertton de Souza; Silva, Diego Augusto Santos; Moura, Bruno Monteiro de; Diefenthaeler, Fernando; Freitas, Cíntia de la Rocha

    2017-08-23

    Accuracy is essential to the validity of functional capacity measurements. To evaluate the error of measurement of functional capacity tests for elders and suggest the use of the technical error of measurement and credibility coefficient. Twenty elders (65.8 ± 4.5 years) completed six functional capacity tests that were simultaneously filmed and timed by four evaluators by means of a chronometer. A fifth evaluator timed the tests by analyzing the videos (reference data). The means of most evaluators for most tests were different from the reference (p error of measurement between tests and evaluators. The Bland-Altman test showed difference in the concordance of the results between methods. Short duration tests showed higher technical error of measurement than longer tests. In summary, tests timed by a chronometer underestimate the real results of the functional capacity. Difference between evaluators' reaction time and perception to determine the start and the end of the tests would justify the errors of measurement. Calculation of the technical error of measurement or the use of the camera can increase data validity.

  1. Measurement properties of continuous text reading performance tests

    NARCIS (Netherlands)

    Verkerk-Brussee, T.; van Nispen, R.M.A.; van Rens, G.H.M.B.

    2014-01-01

    Purpose: Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. Methods: A literature search was

  2. Measurement error in pressure-decay leak testing

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1979-04-01

    The effect of measurement error in presssure-decay leak testing is considered, and examples are presented to demonstrate how it can be properly accomodated in analyzing data from such tests. Suggestions for more effective specification and conduct of leak tests are presented

  3. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.

  4. The C-Test: An Integrative Measure of Crystallized Intelligence

    Directory of Open Access Journals (Sweden)

    Purya Baghaei

    2015-05-01

    Full Text Available Crystallized intelligence is a pivotal broad ability factor in the major theories of intelligence including the Cattell-Horn-Carroll (CHC model, the three-stratum model, and the extended Gf-Gc (fluid intelligence-crystallized intelligence model and is usually measured by means of vocabulary tests and other verbal tasks. In this paper the C-Test, a text completion test originally proposed as a test of general proficiency in a foreign language, is introduced as an integrative measure of crystallized intelligence. Based on the existing evidence in the literature, it is argued that the construct underlying the C-Test closely matches the abilities underlying the language component of crystallized intelligence, as defined in the well-established theories of intelligence. It is also suggested that by carefully selecting texts from pertinent knowledge domains, the factual knowledge component of crystallized intelligence could also be measured by the C-Test.

  5. The influence of different measurement structures on NRTA test procedures

    International Nuclear Information System (INIS)

    Beedgen, R.

    1986-01-01

    The development of sequential statistical test procedures in the area of near real time material accountancy (NRTA) mostly assumed a fixed measurement model of a given model facility. In this paper different measurement models (dispersion matrices) for a sequence of balance periods are studied. They are used to compare the detection probabilities of three different sequential test procedures for losses of material. It is shown how different plant models have an influence on the sensitivity of specified tests. Great importance for that analysis have the optimal loss patterns in each measurement situation

  6. Surface moisture measurement system hardware acceptance test procedure

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1996-01-01

    The purpose of this acceptance test procedure is to verify that the mechanical and electrical features of the Surface Moisture Measurement System are operating as designed and that the unit is ready for field service. This procedure will be used in conjunction with a software acceptance test procedure, which addresses testing of software and electrical features not addressed in this document. Hardware testing will be performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  7. Quality testing as a reserve for rationalization measures

    International Nuclear Information System (INIS)

    Babic, H.G.

    1979-01-01

    The increase in large-scale planning activities and their realization in all fields of quality testing as opposed to the requirements for a reduction of costs emphasizes the necessity of rationaling measures. Especially during the planning phases there are a number of possibilities for solving this problem: the determination of reference dates for production devices based on the preparation of dates with regard to machines and testing, the assignment of the testing frequency in dependence of the quotient from deviations in production and characteristics tolerances, the application of methods of operation planning following different priority rules. Apart from already existing systems for normal and computeraided planning of testing material application by the help of which the most optimal testing material is selected for certain testing jobs systematic representations and programs for the planning of the testing procedure and the testing precision will enrich the joint complex of the organization of testing procedures. (orig./RW) [de

  8. Shear punch and microhardness tests for strength and ductility measurements

    International Nuclear Information System (INIS)

    Lucas, G.E.; Odette, G.R.; Sheckherd, J.W.

    1983-01-01

    In response to the requirements of the fusion reactor materials development program for small-scale mechanical property tests, two techniques have been developed, namely ball microhardness and shear punch tests. The ball microhardness test is based on the repeated measurement at increasing loads of the chordal diameter of an impression made by a spherical penetrator. A correlation has been developed to predict the constitutive relation of the test material from these data. In addition, the indentation pile-up geometry can be analyzed to provide information on the homogeneity of plastic flow in the test material. The shear punch test complements the microhardness test. It is based on blanking a circular disk from a fixed sheet metal specimen. The test is instrumented to provide punch load-displacement data, and these data can be used to determine flow properties of the test material such as yield stress, ultimate tensile strength, work-hardening exponent, and reduction of area

  9. 76 FR 1136 - Electroshock Weapons Test and Measurement Workshop

    Science.gov (United States)

    2011-01-07

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE National Institute of Standards and Technology Electroshock Weapons Test and Measurement Workshop AGENCY: National Institute of Standards and Technology (NIST), United States Department of Commerce. ACTION: Notice...

  10. Instructions for 104-SX liquid level measurement field tests

    International Nuclear Information System (INIS)

    Webb, R.H.

    1994-01-01

    This document provides detailed instructions for field testing a suggested solution of inserting a liner inside the 104-SX failed Liquid Observation Well to gain access for making temporary Liquid Level Measurement until a permanent solution has been provided

  11. Direct tests of measurement uncertainty relations: what it takes.

    Science.gov (United States)

    Busch, Paul; Stevens, Neil

    2015-02-20

    The uncertainty principle being a cornerstone of quantum mechanics, it is surprising that, in nearly 90 years, there have been no direct tests of measurement uncertainty relations. This lacuna was due to the absence of two essential ingredients: appropriate measures of measurement error (and disturbance) and precise formulations of such relations that are universally valid and directly testable. We formulate two distinct forms of direct tests, based on different measures of error. We present a prototype protocol for a direct test of measurement uncertainty relations in terms of value deviation errors (hitherto considered nonfeasible), highlighting the lack of universality of these relations. This shows that the formulation of universal, directly testable measurement uncertainty relations for state-dependent error measures remains an important open problem. Recent experiments that were claimed to constitute invalidations of Heisenberg's error-disturbance relation, are shown to conform with the spirit of Heisenberg's principle if interpreted as direct tests of measurement uncertainty relations for error measures that quantify distances between observables.

  12. The "Test of Financial Literacy": Development and Measurement Characteristics

    Science.gov (United States)

    Walstad, William B.; Rebeck, Ken

    2017-01-01

    The "Test of Financial Literacy" (TFL) was created to measure the financial knowledge of high school students. Its content is based on the standards and benchmarks stated in the "National Standards for Financial Literacy" (Council for Economic Education 2013). The test development process involved extensive item writing and…

  13. Measuring Intelligence with the Goodenough-Harris Drawing Test.

    Science.gov (United States)

    Scott, Linda Howard

    1981-01-01

    Critically evaluates the literature through 1977 on the Goodenough-Harris Drawing Test. Areas reviewed are administration and standardization of the man and woman scales, test ceiling, sex differences, the Quality scale, reliability, criterion validity, validity with measures of academic achievement, cultural variables, and use with the learning…

  14. Test Station for Measuring Aluminum Tube Geometrical Parameters

    CERN Document Server

    Oansea, D; Gongadze, A L; Gostkin, M I; Dedovich, D V; Evtoukhovitch, P G; Comanescu, B; Kotov, S A; Necsoiu, T; Potrap, I N; Rogalev, E V; Tskhadadze, E G; Chelkov, G A

    2001-01-01

    A test station for quality control of aluminum tube outer diameter and wall thickness is presented. The tested tubes are used for drift detector assembly of ATLAS (LHC, CERN) muon system. The outer diameter and wall thickness of aluminium tubes are measured by means of noncontact optical and ultrasonic methods respectively with the accuracy of 3 {\\mu}m. The testing process is automatic and interacts with the production data base.

  15. Validating Grammaticality Judgment Tests: Evidence from Two New Psycholinguistic Measures

    Science.gov (United States)

    Vafaee, Payman; Suzuki, Yuichi; Kachisnke, Ilina

    2017-01-01

    Several previous factor-analytic studies on the construct validity of grammaticality judgment tests (GJTs) concluded that untimed GJTs measure explicit knowledge (EK) and timed GJTs measure implicit knowledge (IK) (Bowles, 2011; R. Ellis, 2005; R. Ellis & Loewen, 2007). It has also been shown that, irrespective of the time condition chosen,…

  16. Radiometric instrumentation and measurements guide for photovoltaic performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.

    1997-04-01

    The Photovoltaic Module and Systems Performance and Engineering Project at the National Renewable Energy Laboratory performs indoor and outdoor standardization, testing, and monitoring of the performance of a wide range of photovoltaic (PV) energy conversion devices and systems. The PV Radiometric Measurements and Evaluation Team (PVSRME) within that project is responsible for measurement and characterization of natural and artificial optical radiation which stimulates the PV effect. The PV manufacturing and research and development community often approaches project members for technical information and guidance. A great area of interest is radiometric instrumentation, measurement techniques, and data analysis applied to understanding and improving PV cell, module, and system performance. At the Photovoltaic Radiometric Measurements Workshop conducted by the PVSRME team in July 1995, the need to communicate knowledge of solar and optical radiometric measurements and instrumentation, gained as a result of NREL`s long-term experiences, was identified as an activity that would promote improved measurement processes and measurement quality in the PV research and manufacturing community. The purpose of this document is to address the practical and engineering need to understand optical and solar radiometric instrument performance, selection, calibration, installation, and maintenance applicable to indoor and outdoor radiometric measurements for PV calibration, performance, and testing applications. An introductory section addresses radiometric concepts and definitions. Next, concepts essential to spectral radiometric measurements are discussed. Broadband radiometric instrumentation and measurement concepts are then discussed. Each type of measurement serves as an important component of the PV cell, module, and system performance measurement and characterization process.

  17. Surface moisture measurement system hardware acceptance test report

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, G.A., Westinghouse Hanford

    1996-05-28

    This document summarizes the results of the hardware acceptance test for the Surface Moisture Measurement System (SMMS). This test verified that the mechanical and electrical features of the SMMS functioned as designed and that the unit is ready for field service. The bulk of hardware testing was performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. The SMMS was developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks.

  18. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  19. Robust Design of Reliability Test Plans Using Degradation Measures.

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Jonathan Wesley; Lane, Jonathan Wesley; Crowder, Stephen V.; Crowder, Stephen V.

    2014-10-01

    With short production development times, there is an increased need to demonstrate product reliability relatively quickly with minimal testing. In such cases there may be few if any observed failures. Thus, it may be difficult to assess reliability using the traditional reliability test plans that measure only time (or cycles) to failure. For many components, degradation measures will contain important information about performance and reliability. These measures can be used to design a minimal test plan, in terms of number of units placed on test and duration of the test, necessary to demonstrate a reliability goal. Generally, the assumption is made that the error associated with a degradation measure follows a known distribution, usually normal, although in practice cases may arise where that assumption is not valid. In this paper, we examine such degradation measures, both simulated and real, and present non-parametric methods to demonstrate reliability and to develop reliability test plans for the future production of components with this form of degradation.

  20. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  1. Modal test - Measurement and analysis requirements. [for Viking Orbiter

    Science.gov (United States)

    Wada, B. K.

    1975-01-01

    Data from the Viking Orbiter Modal Test Program are used to illustrate modal test measurement and analysis requirements. The test was performed using a multiple shake dwell technique where data were acquired one channel at a time and recorded on paper tape. Up to ten shakers were used simultaneously, with a complete set of data consisting of 290 strain-gage readings and 125 accelerometer readings. The data analysis provided information sufficient to minimize errors in the data. The list of analyses in order of value is orthogonality, residual mass, frequency sweep, data checks to assure good test data, multilevel trends, global kinetic energy, and global strain energy.

  2. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  3. Numerical Modelling and Measurement in a Test Secondary Settling Tank

    DEFF Research Database (Denmark)

    Dahl, C.; Larsen, Torben; Petersen, O.

    1994-01-01

    sludge. Phenomena as free and hindered settling and the Bingham plastic characteristic of activated sludge suspensions are included in the numerical model. Further characterisation and test tank experiments are described. The characterisation experiments were designed to measure calibration parameters...... and for comparing measured and calculated result. The numerical model could, fairly accuratly, predict the measured results and both the measured and the calculated results showed a flow field pattern identical to flow fields in full-scale secondary setling tanks. A specific calibration of the Bingham plastic...

  4. Measured data from the Avery Island Site C heater test

    International Nuclear Information System (INIS)

    Waldman, H.; Stickney, R.G.

    1984-11-01

    Over the past six years, a comprehensive field testing program was conducted in the Avery Island salt mine. Three single canister heater tests were included in the testing program. Specifically, electric heaters, which simulate canisters of heat-generating nuclear waste, were placed in the floor of the Avery Island salt mine, and measurements were made of the response of the salt to heating. These tests were in operation by June 1978. One of the three heater tests, Site C, operated for a period of 1858 days and was decommissioned during July and August 1983. This data report presents the temperature and displacement data gathered during the operation and decommissioning of the Site C heater test. The purpose of this data report is to transmit the data to the scientific community. Rigorous analysis and interpretation of the data are considered beyond the scope of a data report. 6 references, 21 figures, 1 table

  5. Testing of Tools for Measurement Vibration in Car

    Directory of Open Access Journals (Sweden)

    Martin JURÁNEK

    2009-06-01

    Full Text Available This work is specialized on testing of several sensors for measurement vibration, that be applicable for measurement on vehicles also behind running. These sensors are connected to PC and universal mobile measuring system cRIO (National Instruments with analog I/O module for measurement vibration, that is described in diploma work: [JURÁNEK 2008]. This system has upped mechanical and heat imunity, small proportions and is therefore acceptable also measurement behind ride vehicles. It compose from two head parts. First is measuring part, composite from instruments cRIO. First part is controlled and monitored by PDA there is connected of wireless (second part hereof system. To system cRIO is possible connect sensors by four BNC connector or after small software change is possible add sensor to other analog modul cRIO. Here will be test several different types of accelerometers (USB sensor company Phidgets, MEMS sensor company Freescale, piezoresistiv and Delta Tron accelerometers company Brüel&Kjær. These sensors is attach to stiff board, board is attach to vibrator and excite by proper signal. Testing will realized with reference to using for measurement in cars. Results will be compared with professional signal analyser LabShop pulse from company Brüel&Kjær.

  6. An automatic system to measure material's resistance to stable crack initiation

    International Nuclear Information System (INIS)

    Bergmann, U.; Bergner, F.; Popp, K.; Schuetzler, H.P.

    1991-06-01

    The unloading compliance technique has become the preferred single specimen method for evaluating the fracture toughness of materials. It involves control of the testing machine as well as data acquisition and analysis using computers. This paper describes in detail the development of a simple experimental system and related software. The method has been applied in order to determine the temperature dependence of fracture toughness of a low-alloy Cr-Mo steel. Results are compared with both measurements at the VTT Espoo and measurements based on a multiple specimen method. (orig.) [de

  7. Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

    Science.gov (United States)

    Winnitoy, Susan

    2012-01-01

    Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic

  8. Gas temperature measurements in short duration turbomachinery test facilities

    Science.gov (United States)

    Cattafesta, L. N.; Epstein, A. H.

    1988-07-01

    Thermocouple rakes for use in short-duration turbomachinery test facilities have been developed using very fine thermocouples. Geometry variations were parametrically tested and showed that bare quartz junction supports (76 microns in diameter) yielded superior performance, and were rugged enough to survive considerable impact damage. Using very low cost signal conditioning electronics, temperature accuracies of 0.3 percent were realized yielding turbine efficiency measurements at the 1-percent level. Ongoing work to improve this accuracy is described.

  9. Data Reconciliation and Gross Error Detection: A Filtered Measurement Test

    International Nuclear Information System (INIS)

    Himour, Y.

    2008-01-01

    Measured process data commonly contain inaccuracies because the measurements are obtained using imperfect instruments. As well as random errors one can expect systematic bias caused by miscalibrated instruments or outliers caused by process peaks such as sudden power fluctuations. Data reconciliation is the adjustment of a set of process data based on a model of the process so that the derived estimates conform to natural laws. In this paper, we will explore a predictor-corrector filter based on data reconciliation, and then a modified version of the measurement test is combined with the studied filter to detect probable outliers that can affect process measurements. The strategy presented is tested using dynamic simulation of an inverted pendulum

  10. Shear Strength Measurement Benchmarking Tests for K Basin Sludge Simulants

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Carolyn A.; Daniel, Richard C.; Enderlin, Carl W.; Luna, Maria; Schmidt, Andrew J.

    2009-06-10

    Equipment development and demonstration testing for sludge retrieval is being conducted by the K Basin Sludge Treatment Project (STP) at the MASF (Maintenance and Storage Facility) using sludge simulants. In testing performed at the Pacific Northwest National Laboratory (under contract with the CH2M Hill Plateau Remediation Company), the performance of the Geovane instrument was successfully benchmarked against the M5 Haake rheometer using a series of simulants with shear strengths (τ) ranging from about 700 to 22,000 Pa (shaft corrected). Operating steps for obtaining consistent shear strength measurements with the Geovane instrument during the benchmark testing were refined and documented.

  11. Specification test for Markov models with measurement errors.

    Science.gov (United States)

    Kim, Seonjin; Zhao, Zhibiao

    2014-09-01

    Most existing works on specification testing assume that we have direct observations from the model of interest. We study specification testing for Markov models based on contaminated observations. The evolving model dynamics of the unobservable Markov chain is implicitly coded into the conditional distribution of the observed process. To test whether the underlying Markov chain follows a parametric model, we propose measuring the deviation between nonparametric and parametric estimates of conditional regression functions of the observed process. Specifically, we construct a nonparametric simultaneous confidence band for conditional regression functions and check whether the parametric estimate is contained within the band.

  12. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Science.gov (United States)

    Yin, Peili; Wang, Jianhua; Lu, Chunxia

    2017-08-01

    Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI). The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI) to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  13. Measuring Software Test Verification for Complex Workpieces based on Virtual Gear Measuring Instrument

    Directory of Open Access Journals (Sweden)

    Yin Peili

    2017-08-01

    Full Text Available Validity and correctness test verification of the measuring software has been a thorny issue hindering the development of Gear Measuring Instrument (GMI. The main reason is that the software itself is difficult to separate from the rest of the measurement system for independent evaluation. This paper presents a Virtual Gear Measuring Instrument (VGMI to independently validate the measuring software. The triangular patch model with accurately controlled precision was taken as the virtual workpiece and a universal collision detection model was established. The whole process simulation of workpiece measurement is implemented by VGMI replacing GMI and the measuring software is tested in the proposed virtual environment. Taking involute profile measurement procedure as an example, the validity of the software is evaluated based on the simulation results; meanwhile, experiments using the same measuring software are carried out on the involute master in a GMI. The experiment results indicate a consistency of tooth profile deviation and calibration results, thus verifying the accuracy of gear measuring system which includes the measurement procedures. It is shown that the VGMI presented can be applied in the validation of measuring software, providing a new ideal platform for testing of complex workpiece-measuring software without calibrated artifacts.

  14. On the Behaviour of Information Measures for Test Selection

    NARCIS (Netherlands)

    Sent, D.; van der Gaag, L.C.; Bellazzi, R; Abu-Hanna, A; Hunter, J

    2007-01-01

    tests that are expected to yield the largest decrease in the uncertainty about a patient’s diagnosis. For capturing diagnostic uncertainty, often an information measure is used. In this paper, we study the Shannon entropy, the Gini index, and the misclassification error for this purpose. We argue

  15. Modernization of laboratories of test of electric measurer

    International Nuclear Information System (INIS)

    Cuervo, Luis Felipe

    1999-01-01

    The paper presents to the companies that possess test laboratories and calibration of electric measurer, an economic alternative for their modernization, using the repontentiation like an economic solution that it liberates resources to be used in other areas that they want it

  16. Measuring Literary Reading Motivation: Questionnaires Design and Pilot Testing

    Science.gov (United States)

    Chrysos, Michail

    2017-01-01

    This study aims to present the design and pilot testing procedures of the two specific self-report questionnaires were used to measure the two key aspects of reading motivation, self-efficacy and intrinsic motivation in the field of literary (narrative) reading, and the partial factors that jointly shape them. These instruments were outlined in…

  17. Data Modeling for Measurements in the Metrology and Testing Fields

    CERN Document Server

    Pavese, Franco

    2009-01-01

    Offers a comprehensive set of modeling methods for data and uncertainty analysis. This work develops methods and computational tools to address general models that arise in practice, allowing for a more valid treatment of calibration and test data and providing an understanding of complex situations in measurement science

  18. Reliability and Validity Testing of the Physical Resilience Measure

    Science.gov (United States)

    Resnick, Barbara; Galik, Elizabeth; Dorsey, Susan; Scheve, Ann; Gutkin, Susan

    2011-01-01

    Objective: The purpose of this study was to test reliability and validity of the Physical Resilience Scale. Methods: A single-group repeated measure design was used and 130 older adults from three different housing sites participated. Participants completed the Physical Resilience Scale, Hardy-Gill Resilience Scale, 14-item Resilience Scale,…

  19. Validation Testing for Automated Solubility Measurement Equipment Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

  20. Detection measures in real-life criminal guilty knowledge tests.

    Science.gov (United States)

    Elaad, E; Ginton, A; Jungman, N

    1992-10-01

    The present study provides a first attempt to compare the validity of the respiration line length (RLL) and skin resistance response (SRR) amplitude in real-life criminal guilty knowledge tests (GKTs). GKT records of 40 innocent and 40 guilty Ss, for whom actual truth was established by confession, were assessed for their accuracy. When a predefined decision rule was used and inconclusive decisions were excluded, 97.4% of the innocent Ss and 53.3% of the guilty Ss were correctly classified with the SRR measure. For the RLL measure, the respective results were 97.2% and 53.1%. The combination of both measures improved detection of guilty Ss to 75.8% and decreased detection of innocent Ss to 94.1%. The combined measure seems to be a more useful means of identifying guilty suspects than each physiological measure alone. The results elaborate and extend those obtained in a previous field study conducted by Elaad (1990).

  1. Comparison of Angle of Attack Measurements for Wind Tunnel Testing

    Science.gov (United States)

    Jones, Thomas, W.; Hoppe, John C.

    2001-01-01

    Two optical systems capable of measuring model attitude and deformation were compared to inertial devices employed to acquire wind tunnel model angle of attack measurements during the sting mounted full span 30% geometric scale flexible configuration of the Northrop Grumman Unmanned Combat Air Vehicle (UCAV) installed in the NASA Langley Transonic Dynamics Tunnel (TDT). The overall purpose of the test at TDT was to evaluate smart materials and structures adaptive wing technology. The optical techniques that were compared to inertial devices employed to measure angle of attack for this test were: (1) an Optotrak (registered) system, an optical system consisting of two sensors, each containing a pair of orthogonally oriented linear arrays to compute spatial positions of a set of active markers; and (2) Video Model Deformation (VMD) system, providing a single view of passive targets using a constrained photogrammetric solution whose primary function was to measure wing and control surface deformations. The Optotrak system was installed for this test for the first time at TDT in order to assess the usefulness of the system for future static and dynamic deformation measurements.

  2. Measurements of rope elongation or deflection in impact destructive testing

    Directory of Open Access Journals (Sweden)

    Adam Szade

    2015-01-01

    Full Text Available The computation of energy dissipation in mechanical protective systems and the corresponding determination of their safe use in mine shafts, requires a precise description of their bending and elongation, for instance, in conditions of dynamic, transverse loading induced by the falling of mass. The task aimed to apply a fast parallactic rangefinder and then to mount it on a test stand, which is an original development of the Central Mining Institute's Laboratory of Rope Testing in Katowice. In the solution presented in this paper, the measuring method and equipment in which the parallactic laser rangefinder, provided with a fast converter and recording system, ensures non-contact measurement of elongation, deflection or deformation of the sample (construction during impact loading. The structure of the unit, and metrological parameters are also presented. Additionally, the method of calibration and examples of the application in the impact tests of steel wire ropes are presented. The measurement data obtained will provide a basis for analysis, the prediction of the energy of events and for applying the necessary means to maintain explosion-proofness in the case of destructive damage to mechanical elements in the mine atmosphere. What makes these measurements novel is the application of a fast and accurate laser rangefinder to the non-contact measurement of crucial impact parameters of dynamic events that result in the destruction of the sample. In addition, the method introduces a laser scanning vibrometer with the aim of evaluating the parameters of the samples before and after destruction.

  3. Standard test method for conducting potentiodynamic polarization resistance measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers an experimental procedure for polarization resistance measurements which can be used for the calibration of equipment and verification of experimental technique. The test method can provide reproducible corrosion potentials and potentiodynamic polarization resistance measurements. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Testing Overall and Subpopulation Treatment Effects with Measurement Errors.

    Science.gov (United States)

    Ma, Yanyuan; Yin, Guosheng

    2013-07-01

    There is a growing interest in the discovery of important predictors from many potential biomarkers for therapeutic use. In particular, a biomarker has predictive value for treatment if the treatment is only effective for patients whose biomarker values exceed a certain threshold. However, biomarker expressions are often subject to measurement errors, which may blur the biomarker's predictive capability in patient classification and, as a consequence, may lead to inappropriate treatment decisions. By taking into account the measurement errors, we propose a new testing procedure for the overall and subpopulation treatment effects in the multiple testing framework. The proposed method bypasses the permutation or other resampling procedures that become computationally infeasible in the presence of measurement errors. We conduct simulation studies to examine the performance of the proposed method, and illustrate it with a data example.

  5. Failing Tests: Commentary on "Adapting Educational Measurement to the Demands of Test-Based Accountability"

    Science.gov (United States)

    Thissen, David

    2015-01-01

    In "Adapting Educational Measurement to the Demands of Test-Based Accountability" Koretz takes the time-honored engineering approach to educational measurement, identifying specific problems with current practice and proposing minimal modifications of the system to alleviate those problems. In response to that article, David Thissen…

  6. Testing limits to airflow perturbation device (APD measurements

    Directory of Open Access Journals (Sweden)

    Jamshidi Shaya

    2008-10-01

    Full Text Available Abstract Background The Airflow Perturbation Device (APD is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Method Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. Results All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O·sec/L for control and 3.9 cm H2O·sec/L for the leak. This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O·sec/L, respectively. Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O·sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O·sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O·sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O·sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O·sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD

  7. Discrete Spectral Local Measurement Method for Testing Solar Concentrators

    Directory of Open Access Journals (Sweden)

    Huifu Zhao

    2012-01-01

    Full Text Available In order to compensate for the inconvenience and instability of outdoor photovoltaic concentration test system which are caused by the weather changes, we design an indoor concentration test system with a large caliber and a high parallelism, and then verify its feasibility and scientificity. Furthermore, we propose a new concentration test method: the discrete spectral local measurement method. A two-stage Fresnel concentration system is selected as the test object. The indoor and the outdoor concentration experiments are compared. The results show that the outdoor concentration efficiency of the two-stage Fresnel concentration system is 85.56%, while the indoor is 85.45%. The two experimental results are so close that we can verify the scientificity and feasibility of the indoor concentration test system. The light divergence angle of the indoor concentration test system is 0.267° which also matches with sunlight divergence angle. The indoor concentration test system with large diameter (145 mm, simple structure, and low cost will have broad applications in solar concentration field.

  8. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  9. Constructing three emotion knowledge tests from the invariant measurement approach

    Directory of Open Access Journals (Sweden)

    Ana R. Delgado

    2017-09-01

    Full Text Available Background Psychological constructionist models like the Conceptual Act Theory (CAT postulate that complex states such as emotions are composed of basic psychological ingredients that are more clearly respected by the brain than basic emotions. The objective of this study was the construction and initial validation of Emotion Knowledge measures from the CAT frame by means of an invariant measurement approach, the Rasch Model (RM. Psychological distance theory was used to inform item generation. Methods Three EK tests—emotion vocabulary (EV, close emotional situations (CES and far emotional situations (FES—were constructed and tested with the RM in a community sample of 100 females and 100 males (age range: 18–65, both separately and conjointly. Results It was corroborated that data-RM fit was sufficient. Then, the effect of type of test and emotion on Rasch-modelled item difficulty was tested. Significant effects of emotion on EK item difficulty were found, but the only statistically significant difference was that between “happiness” and the remaining emotions; neither type of test, nor interaction effects on EK item difficulty were statistically significant. The testing of gender differences was carried out after corroborating that differential item functioning (DIF would not be a plausible alternative hypothesis for the results. No statistically significant sex-related differences were found out in EV, CES, FES, or total EK. However, the sign of d indicate that female participants were consistently better than male ones, a result that will be of interest for future meta-analyses. Discussion The three EK tests are ready to be used as components of a higher-level measurement process.

  10. Standards for measurements and testing of wind turbine power quality

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, P. [Risoe National Lab., Roskilde (Denmark); Gerdes, G.; Klosse, R.; Santjer, F. [DEWI, Wilhelmshaven (Germany); Robertson, N.; Davy, W. [NEL, Glasgow (United Kingdom); Koulouvari, M.; Morfiadakis, E. [CRES, Pikermi (Greece); Larsson, Aa. [Chalmers Univ. of Technology, Goeteborg (Sweden)

    1999-03-01

    The present paper describes the work done in power quality sub-task of the project `European Wind Turbine Testing Procedure Developments` funded by the EU SMT program. The objective of the power quality sub-task has been to make analyses and new recommendation(s) for the standardisation of measurement and verification of wind turbine power quality. The work has been organised in three major activities. The first activity has been to propose measurement procedures and to verify existing and new measurement procedures. This activity has also involved a comparison of the measurements and data processing of the participating partners. The second activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with constant rotor speed. The third activity has been to investigate the influence of terrain, grid properties and wind farm summation on the power quality of wind turbines with variable rotor speed. (au)

  11. submitter Experimental temperature measurements for the energy amplifier test

    CERN Document Server

    Calero, J; Gallego, E; Gálvez, J; García Tabares, L; González, E; Jaren, J; López, C; Lorente, A; Martínez Val, J M; Oropesa, J; Rubbia, C; Rubio, J A; Saldana, F; Tamarit, J; Vieira, S

    1996-01-01

    A uranium thermometer has been designed and built in order to make local power measurements in the First Energy Amplifier Test (FEAT). Due to the experimental conditions power measurements of tens to hundreds of nW were required, implying a sensitivity in the temperature change measurements of the order of 1 mK. A uranium thermometer accurate enough to match that sensitivity has been built. The thermometer is able to determine the absolute energetic gain obtained in a tiny subcritical uranium assembly exposed to a proton beam of kinetic energies between 600 MeV and 2.75 GeV. In addition, the thermometer measurements have provided information about the spatial power distribution and the shape of the neutron spallation cascade.

  12. Design and testing of an innovative solar radiation measurement device

    International Nuclear Information System (INIS)

    Badran, Omar; Al-Salaymeh, Ahmed; El-Tous, Yousif; Abdala, Wasfi

    2010-01-01

    After review of studies conducted on the solar radiation measuring systems, a new innovative instrument that would help in measuring the accurate solar radiation on horizontal surfaces has been designed and tested. An advanced instrument with ease of use and high precision that would enable the user to take the readings in terms of solar intensity (W/m 2 ) has been tested. Also, the innovative instrument can record instantaneous readings of the solar intensities as well as the averages value of the solar radiation flux during certain periods of time. The instrument based in its design on being programmed by programmable interfacing controller (PIC). Furthermore, the power supply circuit is fed by the solar energy cells and does not need an external power source.

  13. Infrared thermography for temperature measurement and non-destructive testing.

    Science.gov (United States)

    Usamentiaga, Rubén; Venegas, Pablo; Guerediaga, Jon; Vega, Laura; Molleda, Julio; Bulnes, Francisco G

    2014-07-10

    The intensity of the infrared radiation emitted by objects is mainly a function of their temperature. In infrared thermography, this feature is used for multiple purposes: as a health indicator in medical applications, as a sign of malfunction in mechanical and electrical maintenance or as an indicator of heat loss in buildings. This paper presents a review of infrared thermography especially focused on two applications: temperature measurement and non-destructive testing, two of the main fields where infrared thermography-based sensors are used. A general introduction to infrared thermography and the common procedures for temperature measurement and non-destructive testing are presented. Furthermore, developments in these fields and recent advances are reviewed.

  14. Infrared Thermography for Temperature Measurement and Non-Destructive Testing

    Science.gov (United States)

    Usamentiaga, Rubèn; Venegas, Pablo; Guerediaga, Jon; Vega, Laura; Molleda, Julio; Bulnes, Francisco G.

    2014-01-01

    The intensity of the infrared radiation emitted by objects is mainly a function of their temperature. In infrared thermography, this feature is used for multiple purposes: as a health indicator in medical applications, as a sign of malfunction in mechanical and electrical maintenance or as an indicator of heat loss in buildings. This paper presents a review of infrared thermography especially focused on two applications: temperature measurement and non-destructive testing, two of the main fields where infrared thermography-based sensors are used. A general introduction to infrared thermography and the common procedures for temperature measurement and non-destructive testing are presented. Furthermore, developments in these fields and recent advances are reviewed. PMID:25014096

  15. Infrared Thermography for Temperature Measurement and Non-Destructive Testing

    Directory of Open Access Journals (Sweden)

    Rubén Usamentiaga

    2014-07-01

    Full Text Available The intensity of the infrared radiation emitted by objects is mainly a function of their temperature. In infrared thermography, this feature is used for multiple purposes: as a health indicator in medical applications, as a sign of malfunction in mechanical and electrical maintenance or as an indicator of heat loss in buildings. This paper presents a review of infrared thermography especially focused on two applications: temperature measurement and non-destructive testing, two of the main fields where infrared thermography-based sensors are used. A general introduction to infrared thermography and the common procedures for temperature measurement and non-destructive testing are presented. Furthermore, developments in these fields and recent advances are reviewed.

  16. Test of Flow Characteristics in Tubular Fuel Assembly I - Establishment of test loop and measurement validation test

    International Nuclear Information System (INIS)

    Park, Jong Hark; Chae, H. T.; Park, C.; Kim, H.

    2005-12-01

    Tubular type fuel has been developed as one of candidates for Advanced HANARO Reactor(AHR). It is necessary to test the flow characteristics such as velocity in each flow channels and pressure drop of tubular type fuel. A hydraulic test-loop to examine the hydraulic characteristics for a tubular type fuel has been designed and constructed. It consists of three parts; a) piping-loop including pump and motor, magnetic flow meter and valves etc, b) test-section part where a simulated tubular type fuel is located, and 3) data acquisition system to get reading signals from sensors or instruments. In this report, considerations during the design and installation of the facility and the selection of data acquisition sensors and instruments are described in detail. Before doing the experiment to measure the flow velocities in flow channels, a preliminary tests have been done for measuring the coolant velocities using pitot-tube and for validating the measurement accuracy as well. Local velocities of the radial direction in circular tubes are measured at regular intervals of 60 degrees by three pitot-tubes. Flow rate inside the circular flow channel can be obtained by integrating the velocity distribution in radial direction. The measured flow rate was compared to that of magnetic flow meter. According to the results, two values had a good agreement, which means that the measurement of coolant velocity by using pitot-tube and the flow rate measured by the magnetic flow meter are reliable. Uncertainty analysis showed that the error of velocity measurement by pitot-tube is less than ±2.21%. The hydraulic test-loop also can be adapted to others such as HANARO 18 and 36 fuel, in-pile system of FTL(Fuel Test Loop), etc

  17. Measuring vulnerability to depression: The Serbian scrambled sentences test - SSST

    Directory of Open Access Journals (Sweden)

    Novović Zdenka

    2014-01-01

    Full Text Available The goal of this study was to establish whether the SSST, a Serbian language scrambled sentences instrument, is a reliable measure of depressive cognitive bias, and whether it captures the suppression tendency as participants exert the additional cognitive effort of memorizing a six-digit number while completing the task. The sample consisted of 1071 students, randomly assigned into two groups. They completed the SSST divided into two blocks of 28 sentences, together with additional cognitive task during either the first or second block, and after that a number of instruments to establish validity of the SSST. The test was shown to be a reliable instrument of depressive cognitive bias. As a measure of suppression the SSST performed partly as expected, only when load was applied in the second half of the test, and fatigue and cognitive effort enhanced suppression. The advantages of the test versus self-description measures were discussed. [Projekat Ministarstva nauke Republike Srbije, br. 179006: Hereditary, environmental, and psychological factors of mental health

  18. Solutions for acceleration measurement in vehicle crash tests

    Science.gov (United States)

    Dima, D. S.; Covaciu, D.

    2017-10-01

    Crash tests are useful for validating computer simulations of road traffic accidents. One of the most important parameters measured is the acceleration. The evolution of acceleration versus time, during a crash test, form a crash pulse. The correctness of the crash pulse determination depends on the data acquisition system used. Recommendations regarding the instrumentation for impact tests are given in standards, which are focused on the use of accelerometers as impact sensors. The goal of this paper is to present the device and software developed by authors for data acquisition and processing. The system includes two accelerometers with different input ranges, a processing unit based on a 32-bit microcontroller and a data logging unit with SD card. Data collected on card, as text files, is processed with a dedicated software running on personal computers. The processing is based on diagrams and includes the digital filters recommended in standards.

  19. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  20. Implementation of Moderator Circulation Test Temperature Measurement System

    International Nuclear Information System (INIS)

    Lim, Yeong Muk; Hong, Seok Boong; Kim, Min Seok; Choi, Hwa Rim; Kim, Hyung Shin

    2016-01-01

    Moderator Circulation Test(MCT) facility is 1/4 scale facility designed to reproduce the important characteristics of moderator circulation in a CANDU6 calandria under a range of operating conditions. MCT is an equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV(Particle Image Velocimetry) is performed under the iso-thermal test conditions. The Korea Atomic Energy Research Institute (KAERI) started implementation of MCT Temperature Measurement System (TMS) using multiple infrared sensors. To control multiple infrared sensors, MCT TMS is implemented using National Instruments (NI) LabVIEW programming language. The MCT TMS is implemented to measure sensor data of multiple infrared sensors using the LabVIEW. The 35 sensor pipes of MCT TMS are divided into 2 ports to meet the minimum measurement time of 0.2 seconds. The software of MCT TMS is designed using collection function and processing function. The MCT TMS has the function of monitoring the states of multiple infrared sensors. The GUI screen of MCT TMS is composed of sensor pipe categories for user

  1. Implementation of Moderator Circulation Test Temperature Measurement System

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Yeong Muk; Hong, Seok Boong; Kim, Min Seok; Choi, Hwa Rim [KAERI, Daejeon (Korea, Republic of); Kim, Hyung Shin [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    Moderator Circulation Test(MCT) facility is 1/4 scale facility designed to reproduce the important characteristics of moderator circulation in a CANDU6 calandria under a range of operating conditions. MCT is an equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV(Particle Image Velocimetry) is performed under the iso-thermal test conditions. The Korea Atomic Energy Research Institute (KAERI) started implementation of MCT Temperature Measurement System (TMS) using multiple infrared sensors. To control multiple infrared sensors, MCT TMS is implemented using National Instruments (NI) LabVIEW programming language. The MCT TMS is implemented to measure sensor data of multiple infrared sensors using the LabVIEW. The 35 sensor pipes of MCT TMS are divided into 2 ports to meet the minimum measurement time of 0.2 seconds. The software of MCT TMS is designed using collection function and processing function. The MCT TMS has the function of monitoring the states of multiple infrared sensors. The GUI screen of MCT TMS is composed of sensor pipe categories for user.

  2. Development and testing of a community flood resilience measurement tool

    Science.gov (United States)

    Keating, Adriana; Campbell, Karen; Szoenyi, Michael; McQuistan, Colin; Nash, David; Burer, Meinrad

    2017-01-01

    Given the increased attention on resilience strengthening in international humanitarian and development work, there is a growing need to invest in its measurement and the overall accountability of resilience strengthening initiatives. The purpose of this article is to present our framework and tool for measuring community-level resilience to flooding and generating empirical evidence and to share our experience in the application of the resilience concept. At the time of writing the tool is being tested in 75 communities across eight countries. Currently 88 potential sources of resilience are measured at the baseline (initial state) and end line (final state) approximately 2 years later. If a flood occurs in the community during the study period, resilience outcome measures are recorded. By comparing pre-flood characteristics to post-flood outcomes, we aim to empirically verify sources of resilience, something which has never been done in this field. There is an urgent need for the continued development of theoretically anchored, empirically verified, and practically applicable disaster resilience measurement frameworks and tools so that the field may (a) deepen understanding of the key components of disaster resilience in order to better target resilience-enhancing initiatives, and (b) enhance our ability to benchmark and measure disaster resilience over time, and (c) compare how resilience changes as a result of different capacities, actions and hazards.

  3. Performance measurements at the fast flux test facility

    International Nuclear Information System (INIS)

    In 1984, Fast Flux Test Facility (FFTF) management recognized the need to develop a measurement system that would quantify the operational performance of the FFTF and the human resources needed to operate it. Driven by declining budgets and the need to safely manage a manpower rampdown at FFTF, an early warning system was developed. Although the initiating event for the early warning system was the need to safely manage a manpower rampdown, many related uses have evolved. The initial desired objective for the FFTF performance measurements was to ensure safety and control of key performance trends. However, the early warning system has provided a more quantitative, supportable basis upon which to make decisions. From this initial narrow focus, efforts in the FFTF plant and supporting organizations are leading to measurement of and, subsequently, improvements in productivity. Pilot projects utilizing statistical process control have started with longer range productivity improvement

  4. The direct measurement of dose enhancement in gamma test facilities

    International Nuclear Information System (INIS)

    Burke, E.A.; Snowden, D.P.; Cappelli, J.R.; Mittleman, S.; Lowe, L.F.

    1989-01-01

    The design and use of a dual cavity ionization chamber for routine measurement of dose enhancement factors in Co-60 gamma test facilities is described. The enhancement factors can be derived directly from the chamber measurements without recourse to reference data that may be difficult to obtain. It is shown, in agreement with earlier work, that the maximum dose enhancement factors can be altered by a factor two as a result of Compton scatter from relatively small amounts of low or high atomic number materials next to the target. The dual chamber permits the ready detection of such effects. This relatively simple device reliably reproduced earlier results obtained by more involved equipment and procedures. Measured enhancement factors are reported for new material combinations not previously examined and compared with recent calculations

  5. AULA virtual reality test as an attention measure: convergent validity with Conners' Continuous Performance Test.

    Science.gov (United States)

    Díaz-Orueta, Unai; Garcia-López, Cristina; Crespo-Eguílaz, Nerea; Sánchez-Carpintero, Rocío; Climent, Gema; Narbona, Juan

    2014-01-01

    The majority of neuropsychological tests used to evaluate attention processes in children lack ecological validity. The AULA Nesplora (AULA) is a continuous performance test, developed in a virtual setting, very similar to a school classroom. The aim of the present study is to analyze the convergent validity between the AULA and the Continuous Performance Test (CPT) of Conners. The AULA and CPT were administered correlatively to 57 children, aged 6-16 years (26.3% female) with average cognitive ability (IQ mean = 100.56, SD = 10.38) who had a diagnosis of attention deficit/hyperactivity disorder (ADHD) according to DSM-IV-TR criteria. Spearman correlations analyses were conducted among the different variables. Significant correlations were observed between both tests in all the analyzed variables (omissions, commissions, reaction time, and variability of reaction time), including for those measures of the AULA based on different sensorial modalities, presentation of distractors, and task paradigms. Hence, convergent validity between both tests was confirmed. Moreover, the AULA showed differences by gender and correlation to Perceptual Reasoning and Working Memory indexes of the WISC-IV, supporting the relevance of IQ measures in the understanding of cognitive performance in ADHD. In addition, the AULA (but not Conners' CPT) was able to differentiate between ADHD children with and without pharmacological treatment for a wide range of measures related to inattention, impulsivity, processing speed, motor activity, and quality of attention focus. Additional measures and advantages of the AULA versus Conners' CPT are discussed.

  6. Thermal tests for laser Doppler perfusion measurements in Raynaud's syndrome

    Science.gov (United States)

    Kacprzak, Michal; Skora, A.; Obidzinska, J.; Zbiec, A.; Maniewski, Roman; Staszkiewicz, W.

    2004-07-01

    The laser Doppler method offers a non-invasive, real time technique for monitoring of blood perfusion in microcirculation. In practical measurements the perfusion index is given only in relative values. Thus, accurate and reproducible results can be only obtained when using a well controlled stimulation test. The aim of this study was evaluation of the thermal stimulation test, which is frequently used to investigate microcirculation in patients with Raynaud's syndrome. Three types of thermal tests, in which air or water with temperature in range 5°C - 40°C were used. Ten normal volunteers and fifteen patients with clinical symptoms of the primary Raynaud's syndrome were enrolled in this study. To estimate skin microcirculation changes during the thermal test, the multichannel laser Doppler system and laser Doppler scanner were used. The obtained results were analyzed from the point of view of the efficiency of these methods and the thermal provocative tests in differentiation of normal subjects and patient with Raynaud's syndrome.

  7. ACCURACY TEST OF MICROSOFT KINECT FOR HUMAN MORPHOLOGIC MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    B. Molnár

    2012-08-01

    Full Text Available The Microsoft Kinect sensor, a popular gaming console, is widely used in a large number of applications, including close-range 3D measurements. This low-end device is rather inexpensive compared to similar active imaging systems. The Kinect sensors include an RGB camera, an IR projector, an IR camera and an audio unit. The human morphologic measurements require high accuracy with fast data acquisition rate. To achieve the highest accuracy, the depth sensor and the RGB camera should be calibrated and co-registered to achieve high-quality 3D point cloud as well as optical imagery. Since this is a low-end sensor, developed for different purpose, the accuracy could be critical for 3D measurement-based applications. Therefore, two types of accuracy test are performed: (1 for describing the absolute accuracy, the ranging accuracy of the device in the range of 0.4 to 15 m should be estimated, and (2 the relative accuracy of points depending on the range should be characterized. For the accuracy investigation, a test field was created with two spheres, while the relative accuracy is described by sphere fitting performance and the distance estimation between the sphere center points. Some other factors can be also considered, such as the angle of incidence or the material used in these tests. The non-ambiguity range of the sensor is from 0.3 to 4 m, but, based on our experiences, it can be extended up to 20 m. Obviously, this methodology raises some accuracy issues which make accuracy testing really important.

  8. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Measurement of Function Post Hip Fracture: Testing a Comprehensive Measurement Model of Physical Function.

    Science.gov (United States)

    Resnick, Barbara; Gruber-Baldini, Ann L; Hicks, Gregory; Ostir, Glen; Klinedinst, N Jennifer; Orwig, Denise; Magaziner, Jay

    2016-07-01

    Measurement of physical function post hip fracture has been conceptualized using multiple different measures. This study tested a comprehensive measurement model of physical function. This was a descriptive secondary data analysis including 168 men and 171 women post hip fracture. Using structural equation modeling, a measurement model of physical function which included grip strength, activities of daily living, instrumental activities of daily living, and performance was tested for fit at 2 and 12 months post hip fracture, and among male and female participants. Validity of the measurement model of physical function was evaluated based on how well the model explained physical activity, exercise, and social activities post hip fracture. The measurement model of physical function fit the data. The amount of variance the model or individual factors of the model explained varied depending on the activity. Decisions about the ideal way in which to measure physical function should be based on outcomes considered and participants. The measurement model of physical function is a reliable and valid method to comprehensively measure physical function across the hip fracture recovery trajectory. © 2015 Association of Rehabilitation Nurses.

  10. Comparison Testings between Two High-temperature Strain Measurement Systems

    Science.gov (United States)

    Lei, J.-F.; Castelli, M. G.; Androjna, D.; Blue, C.; Blue, R.; Lin, R. Y.

    1996-01-01

    An experimental evaluation was conducted at NASA Lewis Research Center to compare and contrast the performance of a newly developed resistance strain gage, the PdCr temperature-compensated wire strain gage, to that of a conventional high-temperature extensometry. The evaluation of the two strain measurement systems was conducted through the application of various thermal and mechanical loading spectra using a high-temperature thermomechanical uniaxial testing system equipped with quartz lamp heating. The purpose of the testing was not only to compare and contrast the two strain sensors but also to investigate the applicability of the PdCr strain gage to the testing environment typically employed when characterizing the high-temperature mechanical behavior of structural materials. Strain measurement capabilities to 8OO C were investigated with a nickel base superalloy IN100 substrate material, and application to titanium matrix composite (TMC) materials was examined with the SCS-6/Ti-15-3 08 system. PdCr strain gages installed by three attachment techniques, namely, flame spraying, spot welding and rapid infrared joining were investigated.

  11. CARS temperature measurements in a hypersonic propulsion test facility

    Science.gov (United States)

    Jarrett, O., Jr.; Smith, M. W.; Antcliff, R. R.; Northam, G. B.; Cutler, A. D.

    1990-01-01

    Static-temperature measurements performed in a reacting vitiated air-hydrogen Mach-2 flow in a duct in Test Cell 2 at NASA LaRC by using a coherent anti-Stokes Raman spectroscopy (CARS) system are discussed. The hypersonic propulsion Test Cell 2 hardware is outlined with emphasis on optical access ports and safety features in the design of the Test Cell. Such design considerations as vibration, noise, contamination from flow field or atmospheric-borne dust, unwanted laser- and electrically-induced combustion, and movement of the sampling volume in the flow are presented. The CARS system is described, and focus is placed on the principle and components of system-to-monochromator signal coupling. Contour plots of scramjet combustor static temperature in a reacting-flow region are presented for three stations, and it is noted that the measurements reveal such features in the flow as maximum temperature near the model wall in the region of the injector footprint.

  12. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    Science.gov (United States)

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  13. Measured and calculated isotopes for a gadolinia lead test assembly

    International Nuclear Information System (INIS)

    Hove, C.M.

    1990-01-01

    The US Department of Energy, Duke Power Company, and the B and W Fuel Company participated in an extended burnup project to develop, irradiate, and examine an advanced fuel assembly design for pressurized water reactors. The assembly uses a urania-gadolinia (UO 2 -Gd 2 O 3 ) burnable absorber fuel mixture along with other fuel performance and design features that enhance uranium utilization. Previous milestones in the gadolinia development of the extended burnup project include development and verification of a neutronics model, measurement of materials properties of gadolinia fuel, and a successful gadolinia lead test assembly (LTA) program. One LTA was discharged as planned after one cycle, four LTAs continued for two more cycles, and one LTA of these four underwent a fourth cycle and reached 58,310 MWd/ton U assembly-average burnup, a world record at the time. Hot-cell destructive examination of gadolinia and non-gadolinia fuel rods from the single-cycle LTA (406.2 effective full-power days irradiation) has been completed. The comparison of measured and calculated isotopics for this LTA is the subject of this paper. A comparison of measured and calculated power distributions is also given, because accurate prediction of core performance during power production is ultimately the most important test of a calculational model

  14. Teacher Competency in Classroom Testing, Measurement Preparation, and Classroom Testing Practices.

    Science.gov (United States)

    Newman, Dorothy C.; Stallings, William M.

    An assessment instrument and a questionnaire (Appendices A and B) were developed to determine how well teachers understand classroom testing principles and to gain information on the measurement preparation and classroom practices of teachers. Two hundred ninety-four inservice teachers, grades 1 through 12, from three urban school systems in…

  15. Reliability of skin testing as a measure of nutritional state

    International Nuclear Information System (INIS)

    Forse, R.A.; Christou, N.; Meakins, J.L.; MacLean, L.D.; Shizgal, H.M.

    1981-01-01

    The reliability of skin testing to assess the nutritional state was evaluated in 257 patients who received total parenteral nutrition (TPN). The nutritional state was assessed by determining body composition, by multiple-isotope dilution. Immunocompetence was simultaneously evaluated by skin testing with five recall antigens. These measurements were carried out before and at two-week intervals during TPN. A statistically significant relationship existed between the response to skin testing and the nutritional state. A body composition consistent with malnutrition was present in the anergic patients, while body composition was normal in the patients who reacted normally to skin testing. However, a considerable overlap existed as 43% of the reactive patients were malnourished, and 21% of the anergic patients were normally nourished. Thirty-seven (43%) of the 86 anergic patients converted and became reactive during TPN, and their body composition improved significantly. The remaining 49 anergic patients (57%) did not convert, and their body composition did not change despite similar nutritional support. The principal difference between the two groups of anergic patients was the nature of the therapy administered. In the anergic patients who converted, therapy was aggressive and appropriate, and clinical improvement occurred in 23 (62.2%) of the patients, with a mortality of 5.4%. In the 49 patients who remained anergic, therapy was often inappropriate or unsuccessful, with clinical improvement in only three (6.1%) of the patients and a mortality of 42.8%. The data demonstrated a significant relationship between the response to skin testing and the nutritional state. However, because of the wide overlap, skin testing does not accurately assess a person's nutritional state. The persistence of the anergic state is indicative of a lack of response to therapy

  16. Standardization of Solar Mirror Reflectance Measurements - Round Robin Test: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meyen, S.; Lupfert, E.; Fernandez-Garcia, A.; Kennedy, C.

    2010-10-01

    Within the SolarPaces Task III standardization activities, DLR, CIEMAT, and NREL have concentrated on optimizing the procedure to measure the reflectance of solar mirrors. From this work, the laboratories have developed a clear definition of the method and requirements needed of commercial instruments for reliable reflectance results. A round robin test was performed between the three laboratories with samples that represent all of the commercial solar mirrors currently available for concentrating solar power (CSP) applications. The results show surprisingly large differences in hemispherical reflectance (sh) of 0.007 and specular reflectance (ss) of 0.004 between the laboratories. These differences indicate the importance of minimum instrument requirements and standardized procedures. Based on these results, the optimal procedure will be formulated and validated with a new round robin test in which a better accuracy is expected. Improved instruments and reference standards are needed to reach the necessary accuracy for cost and efficiency calculations.

  17. Measuring and testing awareness of emotional face expressions.

    Science.gov (United States)

    Sandberg, Kristian; Bibby, Bo Martin; Overgaard, Morten

    2013-09-01

    Comparison of behavioural measures of consciousness has attracted much attention recently. In a recent article, Szczepanowski et al. conclude that confidence ratings (CR) predict accuracy better than both the perceptual awareness scale (PAS) and post-decision wagering (PDW) when using stimuli with emotional content (fearful vs. neutral faces). Although we find the study interesting, we disagree with the conclusion that CR is superior to PAS because of two methodological issues. First, the conclusion is not based on a formal test. We performed this test and found no evidence that CR predicted accuracy better than PAS (p=.4). Second, Szczepanowski et al. used the present version of PAS in a manner somewhat different from how it was originally intended, and the participants may not have been adequately instructed. We end our commentary with a set of recommendations for future studies using PAS. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Test-retest reliability of Attention Network Test measures in schizophrenia.

    Science.gov (United States)

    Hahn, Eric; Ta, Thi Minh Tam; Hahn, Constanze; Kuehl, Linn K; Ruehl, Claudia; Neuhaus, Andres H; Dettling, Michael

    2011-12-01

    The Attention Network Test (ANT) is a well established behavioral measure in neuropsychological research to assess three different facets of selective attention, i.e., alerting, orienting, and conflict processing. Although the ANT has been applied in healthy individuals and various clinical populations, data on retest reliability are scarce in healthy samples and lacking for clinical populations. The objective of the present study was a longitudinal assessment of relevant ANT network measures in healthy controls and schizophrenic patients. Forty-five schizophrenic patients and 55 healthy controls were tested with ANT in a test-retest design with an average interval of 7.4 months between test sessions. Test-retest reliability was analyzed with Pearson and Intra-class correlations. Healthy controls revealed moderate to high test-retest correlations for mean reaction time, mean accuracy, conflict effect, and conflict error rates. In schizophrenic patients, moderate test-retest correlations for mean reaction time, orienting effect, and conflict effect were found. The analysis of error rates in schizophrenic patients revealed very low test-retest correlations. The current study provides converging statistical evidence that the conflict effect and mean reaction time of ANT yield acceptable test-retest reliabilities in healthy controls and, investigated longitudinally for the first time, also in schizophrenia. Obtained differences of alerting and orienting effects in schizophrenia case-control studies should be considered more carefully. The analysis of error rates revealed heterogeneous results and therefore is not recommended for case control studies in schizophrenia. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  20. Innovative testing and measurement solutions for smart grid

    CERN Document Server

    Huang, Qi; Yi, Jianbo; Zhen, Wei

    2015-01-01

    Focuses on sensor applications and smart meters in the newly developing interconnected smart grid Focuses on sensor applications and smart meters in the newly developing interconnected smart grid Presents the most updated technological developments in the measurement and testing of power systems within the smart grid environment Reflects the modernization of electric utility power systems with the extensive use of computer, sensor, and data communications technologies, providing benefits to energy consumers and utility companies alike The leading author heads a group of researchers focusing on

  1. Skin test reactivity among Danish children measured 15 years apart

    DEFF Research Database (Denmark)

    Thomsen, SF; Ulrik, Charlotte Suppli; Porsbjerg, C

    2006-01-01

    BACKGROUND: Knowledge of secular trends in the prevalence of allergy among children stems in large part from questionnaire surveys, whereas repeated cross-sectional studies using objective markers of atopic sensitization are sparse. OBJECTIVES: To investigate whether the prevalence of skin prick...... (n = 527) and the second in 2001 (n = 480). Skin test reactivity to nine common aeroallergens was measured at both occasions. RESULTS: The prevalence of positive SPT to at least one allergen decreased from 24.1% in 1986 to 18.9% in 2001, (p = 0.05). We found a declining prevalence of sensitization...

  2. Testing the consistency between cosmological measurements of distance and age

    Directory of Open Access Journals (Sweden)

    Remya Nair

    2015-05-01

    Full Text Available We present a model independent method to test the consistency between cosmological measurements of distance and age, assuming the distance duality relation. We use type Ia supernovae, baryon acoustic oscillations, and observational Hubble data, to reconstruct the luminosity distance DL(z, the angle-averaged distance DV(z and the Hubble rate H(z, using Gaussian processes regression technique. We obtain estimate of the distance duality relation in the redshift range 0.1

  3. Standard Test Method for Measured Speed of Oil Diffusion Pumps

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the determination of the measured speed (volumetric flow rate) of oil diffusion pumps. 1.2 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. [Using the Implicit Association Test (IAT) to measure implicit shyness].

    Science.gov (United States)

    Aikawa, Atsushi; Fujii, Tsutomu

    2011-04-01

    Previous research has shown that implicitly measured shyness predicted spontaneous shy behavior in social situations, while explicit self-ratings of shyness predicted controlled shy behavior (Asendorpf, Banse, & Mücke, 2002). The present study examined whether these same results would be replicated in Japan. In Study 1, college students (N=47) completed a shyness Implicit Association Test (IAT for shyness) and explicit self-ratings of shyness. In Study 2, friends (N=69) of the Study 1 participants rated those participants on various personality scales. Covariance structure analysis, revealed that only implicit self-concept measured by the shyness IAT predicted other-rated high interpersonal tension (spontaneous shy behavior). Also, only explicit self-concept predicted other-rated low praise seeking (controlled shy behavior). The results of this study are similar to the findings of the previous research.

  5. Interwell tracer testing for residual oil saturation measurement

    International Nuclear Information System (INIS)

    Tang, Joseph

    2004-01-01

    This research focuses mainly on the interpretation of partitioning tracer data for residual oil saturation measurement. As a secondary objective, depending on the progress of the project, it may also look into some commonly encountered phenomena related to tracer interaction with rock matrix such as adsorption and mass transfer into secondary pores. With advancement of interpretation techniques, interwell partitioning tracer tests have become popular in the industry for determining residual oil saturation to water flood or gas flood. With reported successes both in petroleum and environmental industry, it has gained wide recognition as a reliable method for measuring residual oil saturation, along with other standard techniques such as single well tracer testing, sponge coring and log-inject-log. Several levels of interpretation, depending on the degree of sophistication, are available to interpret the tracer data for residual oil saturation determination. These methods range from the simplest analytical methods namely chromatographic transformation and moment analysis to the most intricate finite difference or streamline simulation, with the semi-quantitative Brigham's Model being in between. The residual oil saturations measured by these methods are not necessarily identical. There arises a legitimate question as to what the residual oil saturation values from different methods mean. Brigham's Model has the advantage that it is semi-analytical and requires minimal effort to match the tracer data. Brigham's five spot model will be extended to model the propagation of partitioning tracer for residual oil saturation measurement. The limitation of using the model for irregular pattern will also be addressed. We will also try to construct a 7 spot, 9 spot and line drive based on Brigham's correlation. This model will also be used to study the effect of different Sor in different layers on chromatographic and moment analysis method. Other retention mechanisms such as

  6. Design and Testing of a Flexible Inclinometer Probe for Model Tests of Landslide Deep Displacement Measurement.

    Science.gov (United States)

    Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin

    2018-01-14

    The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model.

  7. Experimental testing facilities for ultrasonic measurements in heavy liquid metal

    International Nuclear Information System (INIS)

    Cojocaru, V.; Ionescu, V.; Nicolescu, D.; Nitu, A.

    2016-01-01

    The thermo-physical properties of Heavy Liquid Metals (HLM), like lead or its alloy, Lead Bismuth Eutectic (LBE), makes them attractive as coolant candidates in advanced nuclear systems. The opaqueness, that is common to all liquid metals, disables all optical methods. For this reason ultrasound waves are used in different applications in heavy liquid metal technology, for example for flow and velocity measurements and for inspection techniques. The practical use of ultrasound in heavy liquid metals still needs to be demonstrated by experiments. This goal requires heavy liquid metal technology facility especially adapted to this task. In this paper is presented an experimental testing facility for investigations of Heavy Liquid Metals acoustic properties, designed and constructed in RATEN ICN. (authors)

  8. Should Soil Testing Services Measure Soil Biological Activity?

    Directory of Open Access Journals (Sweden)

    Alan J. Franzluebbers

    2016-02-01

    Full Text Available Health of agricultural soils depends largely on conservation management to promote soil organic matter accumulation. Total soil organic matter changes slowly, but active fractions are more dynamic. A key indicator of healthy soil is potential biological activity, which could be measured rapidly with soil testing services via the flush of CO during 1 to 3 d following rewetting of dried soil. The flush of CO is related to soil microbial biomass C and has repeatedly been shown strongly related to net N mineralization during standard aerobic incubations. New research is documenting the close association with plant N uptake in semicontrolled greenhouse conditions ( = 0.77, = 36. Field calibrations are underway to relate the flush of CO to the need for in-season N requirement in a variety of crops. An index of soil biological activity can and should be determined to help predict soil health and soil N availability.

  9. Fast recovery strain measurements in a nuclear test environment

    International Nuclear Information System (INIS)

    Kitchen, W.R.; Nauman, W.J.; Vollmer, D.W.

    1979-01-01

    The recovery of early-time (50 μs or less) strain gage data on structural response experiments in underground nuclear tests has been a continuing problem for experimenters at the Nevada Test Site. Strain measurement is one of the primary techniques used to obtain experimental data for model verification and correlation with predicted effects. Peak strains generally occur within 50 to 100 μs of the radiation exposure. Associated with the exposure is an intense electromagnetic impulse that produces potentials of kilovolts and currents of kiloamperes on the experimental structures. For successful operation, the transducer and associated recording system must recover from the initial noise overload and accurately track the strain response within about 50 μs of the nuclear detonation. A gaging and fielding technique and a recording system design that together accomplish these objectives are described. Areas discussed include: (1) noise source model; (2) experimental cassette design, gage application, grounding, and shielding; (3) cable design and shielding between gage and recorder; (4) recorder design including signal conditioner/amplifier, digital encoder, buffer memory, and uphole data transmission; and (5) samples of experimental data

  10. Fabrication and Testing of Viscosity Measuring Instrument (Viscometer

    Directory of Open Access Journals (Sweden)

    A. B. HASSAN

    2006-01-01

    Full Text Available This paper presents the fabrication and testing of a simple and portable viscometer for the measurement of bulk viscosity of different Newtonian fluids. It is aimed at making available the instrument in local markets and consequently reducing or eliminating the prohibitive cost of importation. The method employed is the use of a D.C motor to rotate a disc having holes for infra-red light to pass through and fall on a photo-diode thus undergoing amplification and this signal being translated on a moving-coil meter as a deflection. The motor speed is kept constant but varies with changes in viscosity of the fluid during stirring, which alter signals being read on the meter. The faster is revolution per minute of the disc, the less the deflection on the meter and vise-versa. From the results of tests conducted on various sample fluids using data on standard Newtonian fluids as reliable guide the efficiency of the viscometer was 76.5%.

  11. Designing and Testing a Database for the Qweak Measurement

    Science.gov (United States)

    Holcomb, Edward; Spayde, Damon; Pote, Tim

    2009-05-01

    The aim of the Qweak experiment is to make the most precise determination to date, aside from measurements at the Z-pole, of the Weinberg angle via a measurement of the proton's weak charge. The weak charge determines a particle's interaction with Z-type bosons. According to the Standard Model the value of the angle depends on the momentum of the exchanged Z boson and is well-determined. Deviations from the Standard Model would indicate new physics. During Qweak, bundles of longitudinally polarized electrons will be scattered from a proton target. Elastically scattered electrons will be detected in one of eight quartz bars via the emitted Cerenkov radiation. Periodically the helicity of these electrons will be reversed. The difference in the scattering rates of these two helicity states creates an asymmetry; the Weinberg angle can be calculated from this. Our role in the collaboration was the design, creation, and implementation of a database for the Qweak experiment. The purpose of this database is to store pertinent information, such as detector asymmetries and monitor calibrations, for later access. In my talk I plan to discuss the database design and the results of various tests.

  12. Fidelity of implementation: development and testing of a measure

    Directory of Open Access Journals (Sweden)

    Wiitala Wyndy

    2010-12-01

    Full Text Available Abstract Background Along with the increasing prevalence of chronic illness has been an increase in interventions, such as nurse case management programs, to improve outcomes for patients with chronic illness. Evidence supports the effectiveness of such interventions in reducing patient morbidity, mortality, and resource utilization, but other studies have produced equivocal results. Often, little is known about how implementation of an intervention actually occurs in clinical practice. While studies often assume that interventions are used in clinical practice exactly as originally designed, this may not be the case. Thus, fidelity of an intervention's implementation reflects how an intervention is, or is not, used in clinical practice and is an important factor in understanding intervention effectiveness and in replicating the intervention in dissemination efforts. The purpose of this paper is to contribute to the understanding of implementation science by (a proposing a methodology for measuring fidelity of implementation (FOI and (b testing the measure by examining the association between FOI and intervention effectiveness. Methods We define and measure FOI based on organizational members' level of commitment to using the distinct components that make up an intervention as they were designed. Semistructured interviews were conducted among 18 organizational members in four medical centers, and the interviews were analyzed qualitatively to assess three dimensions of commitment to use--satisfaction, consistency, and quality--and to develop an overall rating of FOI. Mixed methods were used to explore the association between FOI and intervention effectiveness (inpatient resource utilization and mortality. Results Predictive validity of the FOI measure was supported based on the statistical significance of FOI as a predictor of intervention effectiveness. The strongest relationship between FOI and intervention effectiveness was found when an

  13. Fidelity of implementation: development and testing of a measure.

    Science.gov (United States)

    Keith, Rosalind E; Hopp, Faith P; Subramanian, Usha; Wiitala, Wyndy; Lowery, Julie C

    2010-12-30

    Along with the increasing prevalence of chronic illness has been an increase in interventions, such as nurse case management programs, to improve outcomes for patients with chronic illness. Evidence supports the effectiveness of such interventions in reducing patient morbidity, mortality, and resource utilization, but other studies have produced equivocal results. Often, little is known about how implementation of an intervention actually occurs in clinical practice. While studies often assume that interventions are used in clinical practice exactly as originally designed, this may not be the case. Thus, fidelity of an intervention's implementation reflects how an intervention is, or is not, used in clinical practice and is an important factor in understanding intervention effectiveness and in replicating the intervention in dissemination efforts. The purpose of this paper is to contribute to the understanding of implementation science by (a) proposing a methodology for measuring fidelity of implementation (FOI) and (b) testing the measure by examining the association between FOI and intervention effectiveness. We define and measure FOI based on organizational members' level of commitment to using the distinct components that make up an intervention as they were designed. Semistructured interviews were conducted among 18 organizational members in four medical centers, and the interviews were analyzed qualitatively to assess three dimensions of commitment to use--satisfaction, consistency, and quality--and to develop an overall rating of FOI. Mixed methods were used to explore the association between FOI and intervention effectiveness (inpatient resource utilization and mortality). Predictive validity of the FOI measure was supported based on the statistical significance of FOI as a predictor of intervention effectiveness. The strongest relationship between FOI and intervention effectiveness was found when an alternative measure of FOI was utilized based on

  14. Applying the Implicit Association Test to Measure Intolerance of Uncertainty.

    Science.gov (United States)

    Mosca, Oriana; Dentale, Francesco; Lauriola, Marco; Leone, Luigi

    2016-08-01

    Intolerance of Uncertainty (IU) is a key trans-diagnostic personality construct strongly associated with anxiety symptoms. Traditionally, IU is measured through self-report measures that are prone to bias effects due to impression management concerns and introspective difficulties. Moreover, self-report scales are not able to intercept the automatic associations that are assumed to be main determinants of several spontaneous responses (e.g., emotional reactions). In order to overcome these limitations, the Implicit Association Test (IAT) was applied to measure IU, with a particular focus on reliability and criterion validity issues. The IU-IAT and the Intolerance of Uncertainty Inventory (IUI) were administered to an undergraduate student sample (54 females and 10 males) with a mean age of 23 years (SD = 1.7). Successively, participants were asked to provide an individually chosen uncertain event from their own lives that may occur in the future and were requested to identify a number of potential negative consequences of it. Participants' responses in terms of cognitive thoughts (i.e., cognitive appraisal) and worry reactions toward these events were assessed using the two subscales of the Worry and Intolerance of Uncertainty Beliefs Questionnaire. The IU-IAT showed an adequate level of internal consistency and a not significant correlation with the IUI. A path analysis model, accounting for 35% of event-related worry, revealed that IUI had a significant indirect effect on the dependent variable through event-related IU thoughts. By contrast, as expected, IU-IAT predicted event-related worry independently from IU thoughts. In accordance with dual models of social cognition, these findings suggest that IU can influence event-related worry through two different processing pathways (automatic vs. deliberative), supporting the criterion and construct validity of the IU-IAT. The potential role of the IU-IAT for clinical applications was discussed. © The Author

  15. An Improved Measure of Reading Skill: The Cognitive Structure Test

    National Research Council Canada - National Science Library

    Sorrells, Robert

    1997-01-01

    This study compared the construct validity and the predictive validity of a new test, called the Cognitive Structure Test, to multiple-choice tests of reading skill, namely the Armed Forces Vocational...

  16. Can atom-surface potential measurements test atomic structure models?

    Science.gov (United States)

    Lonij, Vincent P A; Klauss, Catherine E; Holmgren, William F; Cronin, Alexander D

    2011-06-30

    van der Waals (vdW) atom-surface potentials can be excellent benchmarks for atomic structure calculations. This is especially true if measurements are made with two different types of atoms interacting with the same surface sample. Here we show theoretically how ratios of vdW potential strengths (e.g., C₃(K)/C₃(Na)) depend sensitively on the properties of each atom, yet these ratios are relatively insensitive to properties of the surface. We discuss how C₃ ratios depend on atomic core electrons by using a two-oscillator model to represent the contribution from atomic valence electrons and core electrons separately. We explain why certain pairs of atoms are preferable to study for future experimental tests of atomic structure calculations. A well chosen pair of atoms (e.g., K and Na) will have a C₃ ratio that is insensitive to the permittivity of the surface, whereas a poorly chosen pair (e.g., K and He) will have a ratio of C₃ values that depends more strongly on the permittivity of the surface.

  17. Pitfalls in the measurement and interpretation of thyroid function tests.

    Science.gov (United States)

    Koulouri, Olympia; Moran, Carla; Halsall, David; Chatterjee, Krishna; Gurnell, Mark

    2013-12-01

    Thyroid function tests (TFTs) are amongst the most commonly requested laboratory investigations in both primary and secondary care. Fortunately, most TFTs are straightforward to interpret and confirm the clinical impression of euthyroidism, hypothyroidism or hyperthyroidism. However, in an important subgroup of patients the results of TFTs can seem confusing, either by virtue of being discordant with the clinical picture or because they appear incongruent with each other [e.g. raised thyroid hormones (TH), but with non-suppressed thyrotropin (TSH); raised TSH, but with normal TH]. In such cases, it is important first to revisit the clinical context, and to consider potential confounding factors, including alterations in normal physiology (e.g. pregnancy), intercurrent (non-thyroidal) illness, and medication usage (e.g. thyroxine, amiodarone, heparin). Once these have been excluded, laboratory artefacts in commonly used TSH or TH immunoassays should be screened for, thus avoiding unnecessary further investigation and/or treatment in cases where there is assay interference. In the remainder, consideration should be given to screening for rare genetic and acquired disorders of the hypothalamic-pituitary-thyroid (HPT) axis [e.g. resistance to thyroid hormone (RTH), thyrotropinoma (TSHoma)]. Here, we discuss the main pitfalls in the measurement and interpretation of TFTs, and propose a structured algorithm for the investigation and management of patients with anomalous/discordant TFTs. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. A blast absorber test: measurement and model results

    NARCIS (Netherlands)

    Eerden, F.J.M. van der; Berg, F. van den; Hof, J. van 't; Arkel, E. van

    2006-01-01

    A blast absorber test was conducted at the Aberdeen Test Centre from 13 to 17 June 2005. The test was set up to determine the absorbing and shielding effect of a gravel pile, of 1.5 meters high and 15 by 15 meters wide, on blasts from large weapons: e.g. armor, artillery or demolition. The blast was

  19. Revisiting test stability: further evidence relating to the measurement ...

    African Journals Online (AJOL)

    In several earlier analyses of two tests of academic literacy – the Test of Academic Literacy Levels (TALL) and its Afrikaans counterpart, the Toets vir Akademiese Geletterdheidsvlakke (TAG) – we have adopted an approach to the problem that tests may be abused (and therefore used to harm people) by discussing various ...

  20. A test battery measuring auditory capabilities of listening panels

    DEFF Research Database (Denmark)

    Ghani, Jody; Ellermeier, Wolfgang; Zimmer, Karin

    2005-01-01

    a battery of tests covering a larger range of auditory capabilities in order to assess individual listeners. The format of all tests is kept as 'objective' as possible by using a three-alternative forced-choice paradigm in which the subject must choose which of the sound samples is different, thus keeping...... the instruction to the subjects simple and common for all tests. Both basic (e.g. frequency discrimination) and complex (e.g. profile analysis) psychoacoustic tests are covered in the battery and a threshold of discrimination or detection is obtained for each test. Data were collected on 24 listeners who had been...... recruited for participation in an expert listening panel for evaluating the sound quality of hi-fi audio systems. The test battery data were related to the actual performance of the listeners when judging the degradation in quality produced by audio codecs....

  1. Measuring and testing awareness of emotional face expressions

    DEFF Research Database (Denmark)

    Sandberg, Kristian; Bibby, Bo Martin; Overgaard, Morten

    2013-01-01

    with emotional content (fearful vs. neutral faces). Although we find the study interesting, we disagree with the conclusion that CR is superior to PAS because of two methodological issues. First, the conclusion is not based on a formal test. We performed this test and found no evidence that CR predicted accuracy...

  2. Measuring What Matters: Robert Sternberg's Enlightened Approach to Admissions Testing

    Science.gov (United States)

    Grace, Catherine O'Neill

    2011-01-01

    Psychologist Robert J. Sternberg's conviction that American standardized testing does not accurately reflect a child's intelligence or potential is far from theoretical. As an elementary school student in the 1950s, he scored poorly on the ubiquitous IQ test of the time, freezing up when the school psychologist entered the room. Thankfully for…

  3. What does the CBM-maze test measure?

    NARCIS (Netherlands)

    Muijselaar, M.M.L.; Kendeou, P.; de Jong, P.F.; van den Broek, P.W.

    2017-01-01

    In this study, we identified the code-related (decoding, fluency) and language comprehension (vocabulary, listening comprehension) demands of the CBM-Maze test, a formative assessment, and compared them to those of the Gates–MacGinitie test, a standardized summative assessment. The demands of these

  4. Joint Integration Test Facility (JITF) Engineering II Performance Measurement Plans

    National Research Council Canada - National Science Library

    Boucher, Joanne

    2001-01-01

    ..., effectiveness, and accountability in federal programs and spending. The plan establishes six separate performance measurements, which correlate directly to customer satisfaction, Intelligence Mission Application (IMA...

  5. Table 1. Summary of Field Testing and Measurement Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Key performance parameters measured during the field demonstration such as lining thickness, compressive strength, Flexural Strength, Modulus of Elasticity, bond...

  6. Skin test reactivity among Danish children measured 15 years apart

    DEFF Research Database (Denmark)

    Thomsen, SF; Ulrik, Charlotte Suppli; Porsbjerg, C

    2006-01-01

    to most allergens tested, statistically significant; however, only for mugwort and Alternaria iridis. Among subjects, who were sensitized to only one allergen, we found significantly fewer individuals with reactions to D. pteronyssinus and mugwort. CONCLUSIONS: The prevalence of atopic sensitization...

  7. Does the 'torque test' measure cerebral dominance in adults?

    Science.gov (United States)

    Demarest, J; Demarest, L

    1980-02-01

    The direction of drawing a circle, labeled the 'torque test' (Blau, 1977), was evaluated in 74 normal adults (age 14 to 44 yr.) as a predictor of both handedness and cerebral dominance on the dichotic listening test. The results indicate that torque is related to handedness but not to lateralization of language. We suggest that circle-drawing by adults is dependent more on the muscle mechanics of the hand than on cerebral dominance.

  8. Measuring teamwork performance: Validity testing of the Team Emergency Assessment Measure (TEAM) with clinical resuscitation teams.

    Science.gov (United States)

    Cooper, Simon; Cant, Robyn; Connell, Cliff; Sims, Lyndall; Porter, Joanne E; Symmons, Mark; Nestel, Debra; Liaw, Sok Ying

    2016-04-01

    To test the resuscitation non-technical Team Emergency Assessment Measure (TEAM) for feasibility, validity and reliability, in two Australian Emergency Departments (ED). Non-technical (teamwork) skills have been identified as inadequate and as such have a significant impact on patient safety. Valid and reliable teamwork assessment tools are an important element of performance assessment and debriefing processes. A quasi experimental design based on observational ratings of resuscitation non-technical skills in two metropolitan ED. Senior nursing staff rated 106 adult resuscitation team events over a ten month period where three or more resuscitation team members attended. Resuscitation events, team performance and validity and reliability data was collected for the TEAM. Most rated events were for full cardiac resuscitation (43%) with 3-15 team members present for an average of 45 min. The TEAM was found to be feasible and quickly completed with minimal or no training. Discriminant validity was good as was internal consistency with a Cronbach alpha of 0.94. Uni-dimensional and concurrent validity also reached acceptable standards, 0.94 and >0.63 (p=teamwork' construct was identified. Non-technical skills overall were good but leadership was rated notably lower than task and teamwork performance indicating a need for leadership training. The TEAM is a feasible, valid and reliable non-technical assessment measure in simulated and real clinical settings. Emergency teams need to develop leadership skills through training and reflective debriefing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2004-01-01

    A special BUT-transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all measured directly, thus...... enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication in drawing of stainless steel...

  10. Bending Under Tension Test with Direct Friction Measurement

    DEFF Research Database (Denmark)

    Andreasen, Jan Lasson; Olsson, David Dam; Chodnikiewicz, K.

    2006-01-01

    A special Bending-Under-Tension (BUT) transducer has been developed in which friction around the tool radius can be directly measured when drawing a plane sheet strip around a cylindrical tool-pin under constant back tension. The front tension, back tension and torque on the tool-pin are all...... measured directly, thus enabling accurate measurement of friction and direct determination of lubricant film breakdown for varying normal pressure, sliding speed, tool radius and tool preheat temperature. The transducer is applied in an experimental investigation focusing on limits of lubrication...... in drawing of stainless steel showing the influence of varying process conditions and the performance of different lubricants....

  11. Verifiable Measurement-Only Blind Quantum Computing with Stabilizer Testing.

    Science.gov (United States)

    Hayashi, Masahito; Morimae, Tomoyuki

    2015-11-27

    We introduce a simple protocol for verifiable measurement-only blind quantum computing. Alice, a client, can perform only single-qubit measurements, whereas Bob, a server, can generate and store entangled many-qubit states. Bob generates copies of a graph state, which is a universal resource state for measurement-based quantum computing, and sends Alice each qubit of them one by one. Alice adaptively measures each qubit according to her program. If Bob is honest, he generates the correct graph state, and, therefore, Alice can obtain the correct computation result. Regarding the security, whatever Bob does, Bob cannot get any information about Alice's computation because of the no-signaling principle. Furthermore, malicious Bob does not necessarily send the copies of the correct graph state, but Alice can check the correctness of Bob's state by directly verifying the stabilizers of some copies.

  12. Implicit measure for yoga research: Yoga implicit association test

    Directory of Open Access Journals (Sweden)

    Judu V Ilavarasu

    2014-01-01

    Conclusions: Implicit measures may be used in the yoga field to assess constructs, which are difficult to self-report or may have social desirability threat. Y-IAT may be used to evaluate implicit preference toward yoga.

  13. Testing measurement invariance of composites using partial least squares

    NARCIS (Netherlands)

    Henseler, Jörg; Ringle, Christian M.; Sarstedt, Marko

    2016-01-01

    Purpose Research on international marketing usually involves comparing different groups of respondents. When using structural equation modeling (SEM), group comparisons can be misleading unless researchers establish the invariance of their measures. While methods have been proposed to analyze

  14. Direct comparison of unloading compliance and potential drop techniques in J-integral testing

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, J.J.; Nanstad, R.K.

    1984-01-01

    Single-specimen J-integral testing is performed commonly with the unloading compliance technique. Use of modern instrumentation techniques and powerful desktop computers have made this technique a standard. However, this testing technique is slow and tedious, with the loading rate fixed at a slow quasi-static rate. For these reasons the dc potential drop technique was investigated for crack length measurement during a J-integral test. For direct comparison, both unloading compliance and potential drop were used simultaneously during a J-integral test. The results showed good agreement between the techniques. However, the potential drop technique showed an offset in crack length due to plastic blunting processes. Taking this offset into account, J/sub Ic/ values calculated by both techniques compared well.

  15. Qualification testing and electrical measurement experience: A manufacturer's view

    Science.gov (United States)

    Arnett, J. C.; Cooley, J. E.; Wingert, T. L.

    1983-01-01

    ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

  16. Tests on measuring astrophysical S-factors with transfer reactions

    CERN Document Server

    Crespo, R

    2002-01-01

    We propose a general method to test the uniqueness property of the Asymptotic Normalization Constant, ANC. We apply this method for the case of the vertex sup 1 sup 0 B -> sup 9 Be+p using a set of different proton-transfer reactions at different energies. Given the limited sets of data for peripheral transfer reactions, we underline the present difficulties in extracting astrophysical S-factors and point out the inadequacy of some of the available data. Finally, we make some suggestions for future experiments in order to make this test conclusive.

  17. Visualization of elongation measurements using an SER universal testing platform

    Czech Academy of Sciences Publication Activity Database

    Pivokonský, Radek; Filip, Petr; Zelenková, Jana

    2015-01-01

    Roč. 25, č. 1 (2015), s. 1-8 ISSN 1430-6395 R&D Projects: GA ČR(CZ) GAP105/11/2342 Institutional support: RVO:67985874 Keywords : elongational viscosity * Universal Testing Platform (SER) * polymer melts * LDPE Subject RIV: BK - Fluid Dynamics Impact factor: 1.241, year: 2015

  18. Measuring Student Achievement in Travel and Tourism. Sample Test Questions.

    Science.gov (United States)

    New York State Education Dept., Albany. Bureau of Business Education.

    The sample test items included in this document are intended as a resource for teachers of Marketing and Distributive Education programs with emphasis on hospitality and recreation marketing, and tourism and travel services marketing. The related curriculum material has been published in the Travel and Tourism syllabus, an advanced-level module in…

  19. Test method for measuring insulation values of cryogenic pipes

    NARCIS (Netherlands)

    Velthuis, J.F.M.; Blokland, H.; Klaver, B.W.; Beld, C. van de

    2010-01-01

    In this paper a large-area heat flux and temperature sensor (HFT) is used for the evaluation of the insulation value of cryogenic pipes. The HFT is flexible and clamp-on. The test method is relatively simple and can be used in-situ. The HFT makes it possible to monitor insulation performance over

  20. Measuring damage in physical model tests of rubble mounds

    NARCIS (Netherlands)

    Hofland, B.; Rosa-Santos, Paulo; Taveira-Pinto, Francisco; Lemos, Rute; Mendonça, A.; Juana Fortes, C

    2017-01-01

    This paper studies novel ways to evaluate armour damage in physical models of coastal structures. High-resolution damage data for reference rubble mound breakwaters obtained under the HYDRALAB+ joint-research project are analysed and discussed. These tests are used to analyse the way to describe

  1. Measurement of acoustic emission signal energy. Calibration and tests

    International Nuclear Information System (INIS)

    Chretien, N.; Bernard, P.; Fayolle, J.

    1975-01-01

    The possibility of using an Audimat W device for analyzing the electric energy of signals delivered by a piezo-electric sensor for acoustic emission was investigated. The characteristics of the prototype device could be improved. The tests performed revealed that the 7075-T651 aluminium alloy can be used as a reference material [fr

  2. 40 CFR 86.154-98 - Measurement procedure; refueling test.

    Science.gov (United States)

    2010-07-01

    ... concentration of methanol as described in § 86.133-96(i)(6). (6) Within one minute of obtaining the initial FID... immediately prior to the test. Warning: If at any time the concentration of hydrocarbons, of methanol, or of methanol and hydrocarbons exceeds 15,000 ppm C, the enclosure should be immediately purged. This...

  3. Development and Testing of Emergency Department Patient Transfer Communication Measures

    Science.gov (United States)

    Klingner, Jill; Moscovice, Ira

    2012-01-01

    Purpose: Communication problems are a major contributing factor to adverse events in hospitals. The contextual environment in small rural hospitals increases the importance of emergency department (ED) patient transfer communication quality. This study addresses the communication problems through the development and testing of ED quality…

  4. Direct current testing to measure corrosiveness of wood preservatives

    Science.gov (United States)

    Samuel L. Zelinka; Douglas R. Rammer; Donald S. Stone; James T. Gilbertson

    2007-01-01

    A qualitative test that mimics the corrosion behaviour of metals in contact with treated wood without using wood specimens would be of great value in rapidly evaluating the corrosiveness of new wood preservatives. The objective of this study was to determine whether the linear polarisation resistance of metals immersed in a solution of preservative chemicals is related...

  5. Test-retest reliability of knee kinematics measurement during gait ...

    African Journals Online (AJOL)

    ACLR) is crucial to minimize the risk of joint degeneration. To achieve this, it is essential that the chosen measurement method can accurately assess knee kinematics and detect the changes in multi-planes of motion. However to date, limited ...

  6. Improving Measurement Precision of Hierarchical Latent Traits Using Adaptive Testing

    Science.gov (United States)

    Wang, Chun

    2014-01-01

    Many latent traits in social sciences display a hierarchical structure, such as intelligence, cognitive ability, or personality. Usually a second-order factor is linearly related to a group of first-order factors (also called domain abilities in cognitive ability measures), and the first-order factors directly govern the actual item responses.…

  7. A Binomial Test of Group Differences with Correlated Outcome Measures

    Science.gov (United States)

    Onwuegbuzie, Anthony J.; Levin, Joel R.; Ferron, John M.

    2011-01-01

    Building on previous arguments for why educational researchers should not provide effect-size estimates in the face of statistically nonsignificant outcomes (Robinson & Levin, 1997), Onwuegbuzie and Levin (2005) proposed a 3-step statistical approach for assessing group differences when multiple outcome measures are individually analyzed…

  8. The GAMMA ® nursing measure: Its development and testing for ...

    African Journals Online (AJOL)

    Background: In the specialised nursing fields of gerontology, oncology, rehabilitation and home-based care where people live with permanent or temporary disabilities, nurses are unable to perform routine and empirical scoring of their patients' abilities to live independently, because of the lack of valid nursing measures ...

  9. Use of tests and measures in marital and family research.

    Science.gov (United States)

    Piotrowski, C

    1999-06-01

    Measures from the marital and family literature were rank ordered by frequency of appearance in the PsycINFO database from 1974-1997. The Family Environment Scale, Dyadic Adjustment Scale, and the Family Adaptability and Cohesion Evaluation Scales were the instruments found to be most used in research.

  10. Field-crop-sprayer potential drift measured using test bench

    NARCIS (Netherlands)

    Balsari, Paolo; Gil, Emilio; Marucco, Paolo; Zande, van de Jan C.; Nuyttens, David; Herbst, Andreas; Gallart, Montserrat

    2017-01-01

    Because of variations in environmental conditions, spray-drift field measurements following ISO 22866:2005 involve complicated and time-consuming experiments often with low repeatability. Therefore, simple, repeatable, and precise alternative drift assessment methods that are complementary to the

  11. Intelligence is what the intelligence test measures. Seriously

    NARCIS (Netherlands)

    van der Maas, H.L.J.; Kan, K.-J.; Borsboom, D.

    2014-01-01

    The mutualism model, an alternative for the g-factor model of intelligence, implies a formative measurement model in which "g" is an index variable without a causal role. If this model is accurate, the search for a genetic of brain instantiation of "g" is deemed useless. This also implies that the

  12. Influence of PBL with open-book tests on knowledge retention measured with progress tests

    NARCIS (Netherlands)

    Heijne-Penninga, M.; Kuks, J. B. M.; Hofman, W. H. A.; Muijtjens, A. M. M.; Cohen-Schotanus, J.

    The influence of problem-based learning (PBL) and open-book tests on long-term knowledge retention is unclear and subject of discussion. Hypotheses were that PBL as well as open-book tests positively affect long-term knowledge retention. Four progress test results of fifth and sixth-year medical

  13. Functional testing using rapid prototyped components and optical measurement.

    Science.gov (United States)

    Wykes, Catherine; Buckberry, Clive; Dale, Martin; Reeves, Mark; Towers, David

    1999-11-01

    Rapid prototyping manufacturing methods such as stereo-lithography, fused deposition modelling, enable real parts to be produced very quickly from CAD models but because the parts are produced in materials which are different from the final component, these cannot readily be used for assessing structural integrity. Electronic speckle pattern interferometry (ESPI) enables full-field measurement of surface displacements, both static and dynamic to be made rapidly. This paper proposes the use of these two techniques together to enable the response of parts to static and dynamic loading to be assessed early on in the design process. It should be possible to make a qualitative assessment by observing the form of the deformation or vibration pattern produced and it may also be possible to make quantitative measurement by developing suitable scaling methods. Some initial experiments have been made looking at the vibration of flat plates and further proposed work is outlined.

  14. Emotional Intelligence Measured in a Highly Competitive Testing Situation

    OpenAIRE

    Sjöberg, Lennart

    2001-01-01

    This is a study in which emotional intelligence (EI) as well as several other personality dimensions were studied in a real, high-stakes, selection situation, N=190. Forty-one trait oriented personality scales were measured and factor analyzed. A factor pattern with four secondary factors was found: EI, emotional stability, rigidity/perfectionism and energy/dominance. These factors were related to standard FFM (Five Factor Model) dimensions, to Hogan's Development Survey ("the dark side of pe...

  15. Development of a Test Rig for Measuring Isentropic Bulk Modulus

    Science.gov (United States)

    2013-01-01

    Reference herein to any specific commercial company, product , process, or service by trade name, trademark, manufacturer, or otherwise, does not...for advertising or product endorsement purposes. Contracted Author As the author(s) is(are) not a Government employee(s), this document...7.1.1 Speed-of-Sound Verification Based on the measurement techniques discussed above, cyclohexane , having a known speed-of- sound of 1228.7 m/s

  16. A test battery measuring auditory capabilities of listening panels

    DEFF Research Database (Denmark)

    Ghani, Jody; Ellermeier, Wolfgang; Zimmer, Karin

    2005-01-01

    While the literature stresses the importance of expert panels and of training in evaluating sound-quality attributes, the abilities of experts have typically only been investigated for a very limited range of tasks (e.g. naming timbral qualities). It is therefore the aim of this study to develop ...... recruited for participation in an expert listening panel for evaluating the sound quality of hi-fi audio systems. The test battery data were related to the actual performance of the listeners when judging the degradation in quality produced by audio codecs....

  17. The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.

    Directory of Open Access Journals (Sweden)

    Yasuyuki Mamiya

    Full Text Available Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB, and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test.The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD and 20 healthy controls (HCs. We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC and the concurrent validity using the Neuropsychiatric Inventory (NPI hallucinations score as a reference. A receiver operating characteristic (ROC analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs.The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82, and moderately correlated with the NPI hallucinations score (rs = 0.42. Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%.Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.

  18. The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.

    Science.gov (United States)

    Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro

    2016-01-01

    Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.

  19. Influence of PBL with open-book tests on knowledge retention measured with progress tests.

    Science.gov (United States)

    Heijne-Penninga, M; Kuks, J B M; Hofman, W H A; Muijtjens, A M M; Cohen-Schotanus, J

    2013-08-01

    The influence of problem-based learning (PBL) and open-book tests on long-term knowledge retention is unclear and subject of discussion. Hypotheses were that PBL as well as open-book tests positively affect long-term knowledge retention. Four progress test results of fifth and sixth-year medical students (n = 1,648) of three medical schools were analyzed. Two schools had PBL driven curricula, and the third one had a traditional curriculum (TC). One of the PBL schools (PBLob) used a combination of open-book (assessing backup knowledge) and closed-book tests (assessing core knowledge); the other two schools (TC and PBLcb) only used closed-book tests. The items of the progress tests were divided into core and backup knowledge. T tests (with Bonferroni correction) were used to analyze differences between curricula. PBL students performed significantly better than TC students on core knowledge (average effect size (av ES) = 0.37-0.74) and PBL students tested with open-book tests scored somewhat higher than PBL students tested without such tests (av ES = 0.23-0.30). Concerning backup knowledge, no differences were found between the scores of the three curricula. Students of the two PBL curricula showed a substantially better long-term knowledge retention than TC students. PBLob students performed somewhat better on core knowledge than PBLcb students. These outcomes suggest that a problem-based instructional approach in particular can stimulate long-term knowledge retention. Distinguishing knowledge into core and backup knowledge and using open-book tests alongside closed-book tests could enhance long-term core knowledge retention.

  20. Tests of Measurement Invariance without Subgroups: A Generalization of Classical Methods

    Science.gov (United States)

    Merkle, Edgar C.; Zeileis, Achim

    2013-01-01

    The issue of measurement invariance commonly arises in factor-analytic contexts, with methods for assessment including likelihood ratio tests, Lagrange multiplier tests, and Wald tests. These tests all require advance definition of the number of groups, group membership, and offending model parameters. In this paper, we study tests of measurement…

  1. Prevalence of diabetic autonomic neuropathy measured by simple bedside tests

    DEFF Research Database (Denmark)

    Dyrberg, Torben Bech; Benn, Jette; Christiansen, J S

    1981-01-01

    To investigate the prevalence of diabetic autonomic neuropathy, five simple bedside tests, beat-to-beat variation during quiet respiration, beat-to-beat variation during forced respiration, heart rate and blood pressure response to standing, heart rate response to exercise, and heart rate response....... The prevalence of diabetic autonomic neuropathy in the whole diabetic population indicated by abnormal response in beat-to-beat variation during forced respiration was 27%. Diabetic autonimic neuropathy increased in frequency with duration of disease. Patients with nephropathy or proliferative retinopathy had...... a significantly higher prevalence of diabetic autonomic neuropathy as indicated by abnormal beat-to-beat variation during forced respirations (p less than 0.01) than patients without these complications....

  2. Very high temperature measurements: Applications to nuclear reactor safety tests

    International Nuclear Information System (INIS)

    Parga, Clemente-Jose

    2013-01-01

    This PhD dissertation focuses on the improvement of very high temperature thermometry (1100 deg. C to 2480 deg. C), with special emphasis on the application to the field of nuclear reactor safety and severe accident research. Two main projects were undertaken to achieve this objective: - The development, testing and transposition of high-temperature fixed point (HTFP) metal-carbon eutectic cells, from metrology laboratory precision (±0.001 deg. C) to applied research with a reasonable degradation of uncertainties (±3-5 deg. C). - The corrosion study and metallurgical characterization of Type-C thermocouple (service temp. 2300 deg. C) prospective sheath material was undertaken to extend the survivability of TCs used for molten metallic/oxide corium thermometry (below 2000 deg. C)

  3. AMS Ground Truth Measurements: Calibrations and Test Lines

    Energy Technology Data Exchange (ETDEWEB)

    Wasiolek, Piotr T. [National Security Technologies, LLC

    2015-12-01

    Airborne gamma spectrometry is one of the primary techniques used to define the extent of ground contamination after a radiological incident. Its usefulness was demonstrated extensively during the response to the Fukushima NPP accident in March-May 2011. To map ground contamination, a set of scintillation detectors is mounted on an airborne platform (airplane or helicopter) and flown over contaminated areas. The acquisition system collects spectral information together with the aircraft position and altitude every second. To provide useful information to decision makers, the count data, expressed in counts per second (cps), need to be converted to a terrestrial component of the exposure rate at 1 meter (m) above ground, or surface activity of the isotopes of concern. This is done using conversion coefficients derived from calibration flights. During a large-scale radiological event, multiple flights may be necessary and may require use of assets from different agencies. However, because production of a single, consistent map product depicting the ground contamination is the primary goal, it is critical to establish a common calibration line very early into the event. Such a line should be flown periodically in order to normalize data collected from different aerial acquisition systems and that are potentially flown at different flight altitudes and speeds. In order to verify and validate individual aerial systems, the calibration line needs to be characterized in terms of ground truth measurements This is especially important if the contamination is due to short-lived radionuclides. The process of establishing such a line, as well as necessary ground truth measurements, is described in this document.

  4. What is the best measure of psychological reactance? An empirical test of two measures.

    Science.gov (United States)

    Quick, Brian L

    2012-01-01

    This study examines two measures of psychological reactance. In search of identifying the best measure, each is compared vis-à-vis the other with respect to reliability and validity by placing each in a nomothetic network with a freedom threat, attitude, motivation, and source appraisal. The results are discussed with an emphasis on future practices regarding the best approach to measure psychological reactance.

  5. Re-measurement of $^{32}$Ar to test the IMME

    CERN Multimedia

    The Isobaric Multiplet Mass Equation (IMME) has been subject to extensive studies in the low-mass region. Especially at the A = 32 quintet, the predicted quadratic form could not be confirmed, possible explanations being the insufficient accuracy of input parameters or higher-order interactions within the nucleon. For this quintet, the uncertainty on the mass-excess values of four of the five T = 2 multiplet members is extremely low: 0.6 keV for $^{32}$Cl, 0.3 keV for $^{32}$S, 0.2 keV for $^{32}$P, and 0.7 keV for $^{32}$Si. In the case of $^{32}$Ar, however, the uncertainty is as large as 1.8 keV. State-of-the-art high-precision Penning-trap mass spectrometry makes it possible to decrease this uncertainty. We propose to remeasure the mass of $^{32}$Ar at the Penning-trap mass spectrometer ISOLTRAP thus decreasing the uncertainty by a factor of 3-5. The proposed measurement is part of an experimental collaboration with JYFLTRAP, where the remaining masses of the T = 2 isospin quintet at A = 32 will be remeas...

  6. Test gear and measurements a collection of useful and tested circuit design ideas'

    CERN Document Server

    Stewart OBE DLitthc, David

    2013-01-01

    This book provides a clear introduction to test gear in the field of electronics. As well as being a first guide to test gear and its use, the book includes much practical information and reference material for the more experienced electronics enthusiast or student.Based on a collection of feature articles originally published in Electronics - the Maplin Magazine, this work by Danny Stewart is sure to be useful to electronics constructors, students and experimenters alike. Details of all the common (and some not-so-common) items of test gear are included, alongside information regarding its us

  7. Measurement of indoor air quality in two new test houses

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, A.T.

    1996-01-01

    This study assessed indoor air quality in two similar, new houses being evaluated for energy performance. One house (A) was built conventionally. The other (B) was an energy-efficient structure. Air samples for individual volatile organic compounds (VOCs), total VOCs (TVOC) and formaldehyde were collected following completion of the interiors of the houses and on several occasions during the following year. Ventilation rates were also determined so that source strengths of airborne contaminants could be estimated with a mass- balance model. There were no substantial differences in indoor air quality between the houses. The TVOC concentrations in House A ranged from 1,700 - 4,400 {mu}p m{sup -3}, with the highest value coinciding with the lowest ventilation rate. The TVOC concentrations in House B were 2,400 - 2,800 {mu}g m{sup -3}. These values are elevated compared to a median value of 700 {mu}g m{sup -3} measured for a large residential study. Formaldehyde concentrations ranged up to 74 {mu}g m{sup -3}. The dominant VOC in both houses was hexanal, an odorous chemical irritant. The concentrations of acetone, pentanal, toluene, alpha-pinene and other aldehydes were also relatively high in both houses. The source strengths of many of the analytes did not decline substantially over the course of the study. The OSB was estimated to contribute substantially to concentrations of formaldehyde and acetone in the houses. The results also suggested that OSB was not the dominant source of pentanal, hexanal and alpha-pinene, all of which had elevated emissions in the houses, possibly from a single source.

  8. A Test for Cluster Bias: Detecting Violations of Measurement Invariance across Clusters in Multilevel Data

    Science.gov (United States)

    Jak, Suzanne; Oort, Frans J.; Dolan, Conor V.

    2013-01-01

    We present a test for cluster bias, which can be used to detect violations of measurement invariance across clusters in 2-level data. We show how measurement invariance assumptions across clusters imply measurement invariance across levels in a 2-level factor model. Cluster bias is investigated by testing whether the within-level factor loadings…

  9. Increase in Testing Efficiency through the Development of an IT-Based Adaptive Testing Tool for Competency Measurement Applied to a Health Worker Training Test Case

    Science.gov (United States)

    Kleinhans, Janne; Schumann, Matthias

    2015-01-01

    In the context of education and training, competency measurement (CM) is a central challenge in competency management. For complex CMs, a compromise must be addressed between the time available and the number of dimensions to be measured or the quality of the measurements. Increasing the efficiency of existing tests for CMs therefore poses a key…

  10. Front-end Electronics for Unattended Measurement (FEUM). Prototype Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, Ryan C.; Morris, Scott J.; Smith, Leon E.; Keller, Daniel T.

    2015-09-16

    The IAEA has requested that PNNL perform an initial set of tests on front-end electronics for unattended measurement (FEUM) prototypes. The FEUM prototype test plan details the tests to be performed, the criteria for evaluation, and the procedures used to execute the tests.

  11. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    Science.gov (United States)

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  12. A comparison of measured and predicted test flow in an expansion tube with air and oxygen test gases

    Science.gov (United States)

    Aaggard, K. V.; Goad, W. K.

    1975-01-01

    Simultaneous time-resolved measurements of temperature, density, pitot pressure, and wall pressure in both air and O2 test gases were obtained in the Langley pilot model expansion tube. These tests show nonequilibrium chemical and vibrational relaxation significantly affect the test-flow condition. The use of an electromagnetic device to preopen the secondary diaphragm before the arrival of the primary shock wave resulted in an improvement in the agreement between the measured pitot pressure and the value inferred from measured density and interface velocity. Boundary-layer splitter plates used to reduce the wall boundary layer show that this disagreement in the measured and inferred pitot pressures is not a result of boundary-layer effects.

  13. TR-PIV Performance Test for a Flow Field Measurement in a Single Rod Test Section

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Yong; Shin, Chang Hwan; Lee, Chi Young; Oh, Dong Seok; In, Wang Kee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    For large enhancement of performance of Pressurized Water Reactor(PWR), dual-cooled fuel is being developed in Korea Atomic Energy Research Institute(KAERI). This nuclear fuel is a ring shape fuel which is different from conventional cylindrical nuclear fuel and cooling water flows both inner and outer channel. For this fuel, it widens the surface area. But it is bigger outer diameter of fuel rods. So, interval between fuel rods narrows. This because of outer channel flow is unstable. So, measurement of turbulence flow and perturbation that influence in heat transfer elevation is important.. To understand heat transfer characteristics by turbulence, measurement of flow perturbation element is necessary. To measure these turbulence characteristics, hot wire anemometer is widely used. However, it has many disadvantages such as low durability of prove, and big probe size. For these reasons, TR-PIV(Time-Resolved Particle Image Velocimetry) system is employed for better flow measurement in our research institute. TR-PIV system is consisted of laser system and high-speed camera that have high frequency. So, was judged that can measurement complicated turbulence flow and perturbation. In this paper, introduce TR-PIV system, and with results acquiring in single rod flow through this system, and wish to introduce about after this practical use plan

  14. TR-PIV Performance Test for a Flow Field Measurement in a Single Rod Test Section

    International Nuclear Information System (INIS)

    Park, Ju Yong; Shin, Chang Hwan; Lee, Chi Young; Oh, Dong Seok; In, Wang Kee

    2011-01-01

    For large enhancement of performance of Pressurized Water Reactor(PWR), dual-cooled fuel is being developed in Korea Atomic Energy Research Institute(KAERI). This nuclear fuel is a ring shape fuel which is different from conventional cylindrical nuclear fuel and cooling water flows both inner and outer channel. For this fuel, it widens the surface area. But it is bigger outer diameter of fuel rods. So, interval between fuel rods narrows. This because of outer channel flow is unstable. So, measurement of turbulence flow and perturbation that influence in heat transfer elevation is important.. To understand heat transfer characteristics by turbulence, measurement of flow perturbation element is necessary. To measure these turbulence characteristics, hot wire anemometer is widely used. However, it has many disadvantages such as low durability of prove, and big probe size. For these reasons, TR-PIV(Time-Resolved Particle Image Velocimetry) system is employed for better flow measurement in our research institute. TR-PIV system is consisted of laser system and high-speed camera that have high frequency. So, was judged that can measurement complicated turbulence flow and perturbation. In this paper, introduce TR-PIV system, and with results acquiring in single rod flow through this system, and wish to introduce about after this practical use plan

  15. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  16. Field Measurements of PCB emissions from Building Surfaces Using a New Portable Emission Test Cell

    DEFF Research Database (Denmark)

    Lyng, Nadja; Haven, Rune; Gunnarsen, Lars Bo

    2016-01-01

    Danish elementary school. The emission test cell was capable of measuring widely varying specific emission rates of PCBtotal (8-3357 ng/(m2·h)). Remediated measures were found to reduce the emission rates by more than 96% compared with similar untreated surfaces. Emission rates may be affected...... by the conditions in the test cell (such as clean air and increased air velocity) and thereby potentially be different without the test cell attached to the surface. Still the measured emission rates obtained by using the test cell are valuable for determination of mitigation strategies. Additionally the test cell...

  17. Electromagnetic pulse measurement system based on optical fiber transmission under radiated-wave test

    International Nuclear Information System (INIS)

    Liu Shunkun; Nie Xin; Chen Xiangyue; Xiang Hui

    2010-01-01

    Radiated-wave Electromagnetic Pulse Simulator is an important device used to study Electromagnetic Pulse effect of large electronic equipment in test. On the characteristic of radiated-EMP simulator test and the needs to measurement system, Electromagnetic Pulse measurement system based on optical fiber transmission and its composition are introduced in the paper. Sort of measurement system and Calibration method of its are present. The expression of uncertainty in Electromagnetic Pulse measurement system is discussed also. The measurement results are analyzed which be gained by radiated field test. (authors)

  18. Measurement Invariance in Confirmatory Factor Analysis: An Illustration Using IQ Test Performance of Minorities

    Science.gov (United States)

    Wicherts, Jelte M.; Dolan, Conor V.

    2010-01-01

    Measurement invariance with respect to groups is an essential aspect of the fair use of scores of intelligence tests and other psychological measurements. It is widely believed that equal factor loadings are sufficient to establish measurement invariance in confirmatory factor analysis. Here, it is shown why establishing measurement invariance…

  19. Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements

    Science.gov (United States)

    Vargas, Magda B.; Counter, Douglas D.

    2011-01-01

    The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.

  20. Local and omnibus goodness-of-fit tests in classical measurement error models

    KAUST Repository

    Ma, Yanyuan

    2010-09-14

    We consider functional measurement error models, i.e. models where covariates are measured with error and yet no distributional assumptions are made about the mismeasured variable. We propose and study a score-type local test and an orthogonal series-based, omnibus goodness-of-fit test in this context, where no likelihood function is available or calculated-i.e. all the tests are proposed in the semiparametric model framework. We demonstrate that our tests have optimality properties and computational advantages that are similar to those of the classical score tests in the parametric model framework. The test procedures are applicable to several semiparametric extensions of measurement error models, including when the measurement error distribution is estimated non-parametrically as well as for generalized partially linear models. The performance of the local score-type and omnibus goodness-of-fit tests is demonstrated through simulation studies and analysis of a nutrition data set.

  1. Impact Strength of Natural Fibre Composites Measured by Different Test Methods: A Review

    Directory of Open Access Journals (Sweden)

    Navaranjan Namasivayam

    2017-01-01

    Full Text Available Different types of impact test methods have been used in recent years to measure the impact resistance of natural fibre composites (NFCs. After reviewing the literature, the impact resistance of flax, hemp, sisal, wood and jute fibre composites that were measured using different test methods have been compared and discussed. It has been learned that the test methods were selected for research interest, industry requirement or availability of test equipment. Each method had its own advantages and limitations. The result from a particular test could be compared but not with the result from other test methods. Most impact test methods were developed for testing ductile-brittle transition of metals. However, each NFC has a different morphology and cannot be comparable to metals in failure mode and energy absorption characteristic during an impact test. A post evaluation of morphology of an NFC sample after an impact test is important to characterise the material.

  2. Combining Blink, Pupil, and Response Time Measures in a Concealed Knowledge Test

    Directory of Open Access Journals (Sweden)

    Travis eSeymour

    2013-02-01

    Full Text Available The response time (RT based Concealed Knowledge Test (CKT has been shown to accurately detect participants’ knowledge of mock-crime related information. Tests based on ocular measures such as pupil size and blink rate have sometimes resulted in poor classification, or lacked detailed classification analyses. The present study examines the fitness of multiple pupil and blink related responses in the CKT paradigm. To maximize classification efficiency, participants’ concealed knowledge was assessed using both individual test measures and combinations of test measures. Results show that individual pupil-size, pupil-slope, and pre-response blink-rate measures produce efficient classifications. Combining pupil and blink measures yielded more accuracy classifications than individual ocular measures. Although RT-based tests proved efficient, combining RT with ocular measures had little incremental benefit. It is argued that covertly assessing ocular measures during RT-based tests may guard against effective countermeasure use in applied settings. A compound classification procedure was used to categorize individual participants and yielded high hit rates and low false-alarm rates without the need for adjustments between test paradigms or subject populations. We conclude that with appropriate test paradigms and classification analyses, ocular measures may prove as effective as other indices, though additional research is needed.

  3. Test, measurement and evaluation with the mine boot test and evaluation system

    CSIR Research Space (South Africa)

    Ramaloko, PM

    2014-09-01

    Full Text Available limb when detonated. These devices affect both military and civilian personnel indiscriminately. As such, there is a need for development of personal protective equipment (PPE) for military or humanitarian demining. A mine boot is one of such personal... with no footwear protection fitted. Experimental protective footwear is then fitted to the surrogate lower leg, and measured levels compared to the zero level to compare protection values. 2 South African Ballistics Organisation Conference, Pretoria, 29...

  4. An Effect Size Measure for Raju's Differential Functioning for Items and Tests

    Science.gov (United States)

    Wright, Keith D.; Oshima, T. C.

    2015-01-01

    This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…

  5. 77 FR 17457 - Work Group on Alternative Test Methods for Commercial Measuring Devices

    Science.gov (United States)

    2012-03-26

    ... and standards (e.g., neck-type volumetric field standards and associated test procedures) widely used by weights and measures officials and service companies to test commercial measuring devices as well... associated meetings is intended to bring together government officials and representatives of business...

  6. In situ measurement of solvent-mediated phase transformations during dissolution testing

    DEFF Research Database (Denmark)

    Aaltonen, Jaakko; Heinänen, Paula; Peltonen, Leena

    2006-01-01

    In this study, solvent-mediated phase transformations of theophylline (TP) and nitrofurantoin (NF) were measured in a channel flow intrinsic dissolution test system. The test set-up comprised simultaneous measurement of drug concentration in the dissolution medium (with UV-Vis spectrophotometry...

  7. 10 CFR 431.16 - Test procedures for the measurement of energy efficiency.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures for the measurement of energy efficiency. 431.16 Section 431.16 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... Methods of Determining Efficiency § 431.16 Test procedures for the measurement of energy efficiency. For...

  8. Writing Multiple-Choice Test Items that Promote and Measure Critical Thinking.

    Science.gov (United States)

    Morrison, Susan; Free, Kathleen Walsh

    2001-01-01

    Presents guidelines for developing multiple-choice tests to measure critical thinking in nursing. Explains the rationale for test items and describes item criteria, including measurement of cognition at the application level and above, multilogical thinking, and high level of discrimination. (Contains 38 references.) (SK)

  9. Situational judgment tests : from measures of situational judgment to measures of general domain Knowledge

    OpenAIRE

    Lievens, Filip; Motowidlo, Stephan J

    2016-01-01

    Situational judgment tests (SJTs) are typically conceptualized as contextualized selection procedures that capture candidate responses to a set of relevant job situations as a basis for prediction. SJTs share their sample-based and contextualized approach with work samples and assessment center exercises, although they differ from these other simulations by presenting the situations in a low-fidelity (e.g., written) format. In addition, SJTs do not require candidates to respond through actual...

  10. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  11. Strain measurement in and analysis for hydraulic test of CPR1000 reactor pressure vessel

    International Nuclear Information System (INIS)

    Zhou Dan; Zhuang Dongzhen

    2013-01-01

    The strain measurement in hydraulic test of CPR1000 reactor pressure vessel performed in Dongfang Heavy Machinery Co., Ltd. is introduced. The detail test scheme and method was introduced and the measurement results of strain and stress was given. Meanwhile the finite element analysis was performed for the pressure vessel, which was generally matched with the measurement results. The reliability of strain measurement was verified and the high strength margin of vessel was shown, which would give a good reference value for the follow-up hydraulic tests and strength analysis of reactor pressure vessel. (authors)

  12. Testing and Measurement Potentials of Microcomputers for Cognitive Style Research and Individualized Instruction.

    Science.gov (United States)

    Burroway, Robert L.

    Microcomputer versions of three commonly used cognitive style measurement instruments are described and demonstrated: the Leveling-Sharpening House Test (LSHT) (Santostefano, 1964); Lowenfeld's Successive Impressions Test I (SIT-I) (1945); and the Group Embedded Figures Test (GEFT) (Witkin, Oltman, Ruskin, and Karp, 1971). At present, many…

  13. 10 CFR 431.193 - Test procedures for measuring energy consumption of distribution transformers.

    Science.gov (United States)

    2010-01-01

    ... distribution transformers. 431.193 Section 431.193 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Distribution Transformers Test Procedures § 431.193 Test procedures for measuring energy consumption of distribution transformers. The test...

  14. The squares test as a measure of hand function in multiple sclerosis

    NARCIS (Netherlands)

    Gielen, Jeroen; Laton, Jorne; Van Schependom, J.; De Deyn, P. P.; Nagels, Guy

    Deterioration of hand function can be important in multiple sclerosis (MS). The standard way of assessing hand function in MS is the 9-hole peg test (9HPT), one of the three components of the MS functional composite measure. In this study we examine the squares test (ST), a test of hand function

  15. Comparison of accuracy measures of two screening tests for gestational diabetes mellitus

    NARCIS (Netherlands)

    van Leeuwen, Marsha; Zweers, Egbert J. K.; Opmeer, Brent C.; van Ballegooie, Evert; ter Brugge, Henk G.; de Valk, Harold W.; Mol, Ben W. J.; Visser, Gerard H. A.

    2007-01-01

    OBJECTIVE: To compare the accuracy measures of the random glucose test and the 50-g glucose challenge test as screening tests for gestational diabetes mellitus (GDM). RESEARCH DESIGN AND METHODS: In this prospective cohort study, pregnant women without preexisting diabetes in two perinatal centers

  16. A generalized Jonckheere test against ordered alternatives for repeated measures in randomized blocks.

    Science.gov (United States)

    Zhang, Ying; Cabilio, Paul

    2013-05-10

    Focusing on statistical methods in patient-reported outcomes, we propose and develop a generalized Jonckheere test against ordered alternatives for repeated measures in a randomized block design. We derive its asymptotic null distribution properties and describe methods for estimating the null distribution for testing the hypothesis. We present a numerical example to illustrate the test procedure. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Flexible test automation a software framework for easily developing measurement applications

    CERN Document Server

    Arpaia, Pasquale; De Matteis, Ernesto

    2014-01-01

    In laboratory management of an industrial test division, a test laboratory, or a research center, one of the main activities is producing suitable software for automatic benches by satisfying a given set of requirements. This activity is particularly costly and burdensome when test requirements are variable over time. If the batches of objects have small size and frequent occurrence, the activity of measurement automation becomes predominating with respect to the test execution. Flexible Test Automation shows the development of a software framework as a useful solution to satisfy this exigency. The framework supports the user in producing measurement applications for a wide range of requirements with low effort and development time.

  18. Museum Exhibition on Testing and Measurement: Scientific Principles, Social Impact of Testing, and Dialogue with the Public

    Science.gov (United States)

    Allalouf, Avi; Alderoqui-Pinus, Diana

    2012-01-01

    This article deals with a pioneering project currently being developed, namely, the Exhibition on Testing and Measurement. This interactive traveling exhibition will be presented in science museums in Israel, the United States, and other countries. It has been conceived as an innovative means of familiarizing the public with educational…

  19. Measurement invariance in confirmatory factor analysis: an illustration using IQ test performance of minorities

    NARCIS (Netherlands)

    Wicherts, J.M.; Dolan, C.V.

    2010-01-01

    Measurement invariance with respect to groups is an essential aspect of the fair use of scores of intelligence tests and other psychological measurements. It is widely believed that equal factor loadings are sufficient to establish measurement invariance in confirmatory factor analysis. Here, it is

  20. Measurements of coarse control arm drop characteristics in the materials testing reactor HIFAR

    International Nuclear Information System (INIS)

    Marshall, J.; Blevins, R.J.

    1983-02-01

    Measurements were made of the angular position/time characteristics of a coarse control arm in the AAEC's materials testing reactor HIFAR, following a trip. The method of measurment is described and the results are presented. It is clear that all of the measured transients may be reasonably fitted by a single differential equation

  1. Vaginal Swab Test Compared With the Urethral Q-tip Test for Urethral Mobility Measurement: A Randomized Controlled Trial.

    Science.gov (United States)

    Meyer, Isuzu; Szychowski, Jeff M; Illston, Jana D; Parden, Alison M; Richter, Holly E

    2016-02-01

    To assess whether use of a vaginal cotton-tipped swab is equivalent to the standard Q-tip test regarding urethral mobility. Secondarily, to examine whether both tests agree in hypermobility diagnosis, discomfort level, and patients' preference. In this randomized crossover trial, women with stress urinary incontinence without prolapse beyond the hymen were randomized to undergo either a vaginal or urethral mobility test first followed by the alternate approach. The primary outcome was the difference in rotation angle, from resting to maximum strain, between tests. The equivalence margin was ±10°. The secondary outcome was agreement in hypermobility diagnosis using two definitions: 1) maximum straining angle of 30° or greater from the horizontal plane; and 2) rotation angle 30° or greater. Discomfort was assessed using a 0-10 visual analog scale. Using 90% power assuming a standard deviation of 20°, 36 and 139 patients were needed for 10° and 5° equivalence margins, respectively. From January 2014 to March 2015, 140 women were randomized. The mean difference between the two tests was 5.1° (95% confidence interval 3.2-6.9°), meeting the predefined equivalence criteria. In the hypermobility diagnosis, the urethral and vaginal tests had no disagreement using definition 1 (P=.23), whereas the two tests disagreed using definition 2 (P=.03). The urethral approach had a higher discomfort level (Pstandard Q-tip test in measuring urethral mobility with less discomfort and is preferred by patients.

  2. Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

    Science.gov (United States)

    Kurzeja, R. J.; Buckley, R. L.; Werth, D. W.; Chiswell, S. R.

    2018-03-01

    A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

  3. Measuring attention in very old adults using the Test of Everyday Attention.

    Science.gov (United States)

    van der Leeuw, Guusje; Leveille, Suzanne G; Jones, Richard N; Hausdorff, Jeffrey M; McLean, Robert; Kiely, Dan K; Gagnon, Margaret; Milberg, William P

    2017-09-01

    There is a need for validated measures of attention for use in longitudinal studies of older populations. We studied 249 participants aged 80 to 101 years using the population-based MOBILIZE Boston Study. Four subscales of the Test of Everyday Attention (TEA) were included, measuring attention switching, selective, sustained and divided attention and a neuropsychological battery including validated measures of multiple cognitive domains measuring attention, executive function and memory. The TEA previously has not been validated in persons aged 80 and older. Among participants who completed the TEA, scores on other attentional measures strongly with TEA domains (R=.60-.70). Proportions of participants with incomplete TEA subscales ranged from 8% (selective attention) to 19% (attentional switching). Reasons for not completing TEA tests included failure to comprehend test instructions despite repetition and practice. These results demonstrate the challenges and potential value of the Test of Everyday Attention in studies of very old populations.

  4. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    Science.gov (United States)

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  5. Production of test gases in the ppb range for round-robin tests and quality assurance measures during the measurement of VOCs.

    Science.gov (United States)

    Moritz, Andreas; Breuer, Dietmar

    2008-12-01

    Workers exposed to volatile organic compounds (VOCs) very often suffer damage to health, and VOC odours may also represent a serious nuisance. The compounds concerned may be numerous and highly diverse; the concentrations of the individual substances however are generally relatively low. Quality assurance measures such as round-robin tests for the measurement of VOCs in indoor areas or at workplaces have not so far been available. A particular reason for this is the challenge presented by the production of test gases in the necessary concentrations. The BGIA test gas facility has therefore been modified for the production of test gases in the microg/m(3) range. A two-stage primary gas purifier, a continuous test gas generator with multi-stage dilution, a capillary evaporator for low-volatility compounds and an online thermodesorber have been installed specifically for this purpose.Purification of the primary gas proved to be particularly difficult: the available pre-purified compressed air contained organic trace impurities which fluctuated over time. The essential requirement, i.e. the injection into the test gas stream of a primary gas which was constant over time and exhibited the lowest possible contamination, could be satisfied only by catalytic decomposition of the organic residual impurities and with a supplementary adsorber unit. Even with these measures in place, small quantities of organic substances remain present, and the blank readings must still be monitored continuously. Following completion of all modifications, it proved possible to produce test gases with a high degree of reproducibility with substance concentrations in the range of 1 to 500 microg/m(3).Since 2007, the BGIA has been offering round-robin tests for VOCs with local sampling in the range from 5 to 50 microg/m(3). The first round-robin tests show that good results are obtained at concentrations from 10 to 50 microg/m(3). At the lower concentration of < 15 microg/m(3), however, the

  6. The EORTC computer-adaptive tests measuring physical functioning and fatigue exhibited high levels of measurement precision and efficiency

    NARCIS (Netherlands)

    Petersen, M.A.; Aaronson, N.K.; Arraras, J.I.; Chie, W.C.; Conroy, T.; Costantini, A.; Giesinger, J.M.; Holzner, B.; King, M.T.; Singer, S.; Velikova, G.; de Leeuw, I.M.; Young, T.; Groenvold, M.

    2013-01-01

    Objectives: The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is developing a computer-adaptive test (CAT) version of the EORTC Quality of Life Questionnaire (QLQ-C30). We evaluated the measurement properties of the CAT versions of physical functioning (PF)

  7. The EORTC computer-adaptive tests measuring physical functioning and fatigue exhibited high levels of measurement precision and efficiency

    DEFF Research Database (Denmark)

    Petersen, Morten Aa; Aaronson, Neil K; Arraras, Juan I

    2013-01-01

    The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is developing a computer-adaptive test (CAT) version of the EORTC Quality of Life Questionnaire (QLQ-C30). We evaluated the measurement properties of the CAT versions of physical functioning (PF...

  8. The EORTC computer-adaptive tests measuring physical functioning and fatigue exhibited high levels of measurement precision and efficiency

    NARCIS (Netherlands)

    Petersen, M.A.; Aaronson, N.K.; Arraras, J.I.; Chie, W.C.; Conroy, T.; Constantini, A.; Giesinger, J.M.; Holzner, B.; King, M.T.; Singer, S.; Velikova, G.; Verdonck-de Leeuw, I.M.; Young, T.; Groenvold, M.

    2013-01-01

    Objectives The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is developing a computer-adaptive test (CAT) version of the EORTC Quality of Life Questionnaire (QLQ-C30). We evaluated the measurement properties of the CAT versions of physical functioning (PF)

  9. Construct Validity and Measurement Invariance of Computerized Adaptive Testing: Application to Measures of Academic Progress (MAP) Using Confirmatory Factor Analysis

    Science.gov (United States)

    Wang, Shudong; McCall, Marty; Jiao, Hong; Harris, Gregg

    2012-01-01

    The purposes of this study are twofold. First, to investigate the construct or factorial structure of a set of Reading and Mathematics computerized adaptive tests (CAT), "Measures of Academic Progress" (MAP), given in different states at different grades and academic terms. The second purpose is to investigate the invariance of test…

  10. Well test: production analysis and allocation measurement; Teste de poco: analise da producao e medicao de apropriacao

    Energy Technology Data Exchange (ETDEWEB)

    Geron, Luis Carlos [Smar Equipamentos Industriais Ltda., Sertaozinho, SP (Brazil). Dept. de Engenharia Aplicacoes; Tateishi, Sergio Hideki [Smar Equipamentos Industriais Ltda, Sertaozinho, SP (Brazil). Dept. de Pesquisa e Desenvolvimento

    2008-07-01

    The well test is an instrument frequently used to evaluate the production capacity of wells and it usually has specific requirements in the flow measurement, that are not necessary in the flow measurement system for custody transfer applications. Starting with the requirement to measure the injected product in the well when it is in the recuperation phase and it also includes compliance to specific standards for allocation measurement, because these hydrocarbon products are not treated as well as that ones in the production streams. Other important issue associated to the well test is the employment of new technologies, that helps to reduce the uncertainty of measurement as digital communication between the field devices and the flow computer through an open protocol as the Foundation Field bus. Another indication of technology evolution in the flow measurement focusing a lower uncertainty is the new version of API MPMS 11.1:2004, that requires calculation with double precision floating point, as well the correction factors with 5 decimal digits. (author)

  11. A hinged-pad test structure for sliding friction measurement in micromachining

    Energy Technology Data Exchange (ETDEWEB)

    Boer, M.P. de; Redmond, J.M.; Michalske, T.A.

    1998-08-01

    The authors describe the design, modeling, fabrication and initial testing of a new test structure for friction measurement in MEMS. The device consists of a cantilevered forked beam and a friction pad attached via a hinge. Compared to previous test structures, the proposed structure can measure friction over much larger pressure ranges, yet occupies one hundred times less area. The placement of the hinge is crucial to obtaining a well-known and constant pressure distribution in the device. Static deflections on the device were measured and modeled numerically, Preliminary results indicate that friction pad slip is sensitive to friction pad normal force.

  12. Measurement error of a simplified protocol for quantitative sensory tests in chronic pain patients

    DEFF Research Database (Denmark)

    Müller, Monika; Biurrun Manresa, José; Limacher, Andreas

    2017-01-01

    BACKGROUND AND OBJECTIVES: Large-scale application of Quantitative Sensory Tests (QST) is impaired by lacking standardized testing protocols. One unclear methodological aspect is the number of records needed to minimize measurement error. Traditionally, measurements are repeated 3 to 5 times......, and their mean value is considered. When transferring QST to a clinical setting, reducing the number of records would be desirable to meet the time constraints encountered in a routine clinical environment and to reduce the testing burden to chronic pain patients. However, there might be a trade-off between...... to reduce the testing burden. This would allow saving time, resources, and patient discomfort....

  13. Test results of the signal processing and amplifier unit for the emittance measurement system

    International Nuclear Information System (INIS)

    Stawiszynski, L.; Schneider, S.

    1984-01-01

    The signal processing and amplifier unit for the emittance measurement system is the unit with which the beam current on the harp-wires and the slit is measured and converted to a digital output. Temperature effects are very critical at low currents and the purpose of the test measurements described in this report was mainly to establish the accuracy and repeatability of the measurements under the influence of temperature variations

  14. Software Sub-system in Loading Automatic Test System for the Measurement of Power Line Filters

    Directory of Open Access Journals (Sweden)

    Yu Bo

    2017-01-01

    Full Text Available The loading automatic test system for measurement of power line filters are in urgent demand. So the software sub-system of the whole test system was proposed. Methods: structured the test system based on the virtual instrument framework, which consisted of lower and up computer and adopted the top down approach of design to perform the system and its modules, according to the measurement principle of the test system. Results: The software sub-system including human machine interface, data analysis and process software, expert system, communication software, control software in lower computer, etc. had been designed. Furthermore, it had been integrated into the entire test system. Conclusion: This sub-system provided a fiendly software platform for the whole test system, and had many advantages such as strong functions, high performances, low prices. It not only raises the test efficiency of EMI filters, but also renders some creativities.

  15. Comparison of a Micro-Neutralization Test with the Rapid Fluorescent Focus Inhibition Test for Measuring Rabies Virus Neutralizing Antibodies

    Directory of Open Access Journals (Sweden)

    Todd G. Smith

    2017-07-01

    Full Text Available The rapid fluorescent focus inhibition test (RFFIT is routinely used in the United States to measure rabies virus neutralizing antibodies (rVNA. RFFIT has a long history of reproducible and reliable results. The test has been modified over the years to use smaller volumes of reagents and samples, but requires a 50 μL minimum volume of test serum. To conduct pathogenesis studies, small laboratory animals such as mice are regularly tested for rVNA, but the minimum volume for a standard RFFIT may be impossible to obtain, particularly in scenarios of repeated sampling. To address this problem, a micro-neutralization test was developed previously. In the current study, the micro-neutralization test was compared to the RFFIT using 129 mouse serum samples from rabies vaccine studies. Using a cut-off value of 0.1 IU/mL, the sensitivity, specificity, and concordance of the micro-neutralization test were 100%, 97.5%, and 98%, respectively. The geometric mean titer of all samples above the cut-off was 2.0 IU/mL using RFFIT and 3.4 IU/mL using the micro-neutralization test, indicating that titers determined using the micro-neutralization test are not equivalent to RFFIT titers. Based on four rVNA-positive hamster serum samples, the intra-assay coefficient of variability was 24% and inter-assay coefficient of variability was 30.4%. These results support continued use of the micro-neutralization test to determine rabies virus neutralizing antibody titers for low-volume serum samples.

  16. Linear variable differential transformer (LVDT)-based elongation measurements in Advanced Test Reactor high temperature irradiation testing

    International Nuclear Information System (INIS)

    Knudson, D.L.; Rempe, J.L.

    2012-01-01

    New materials are being considered for fuel, cladding, and structures in next generation and existing nuclear reactors. These materials can undergo significant dimensional and physical changes during high temperature irradiations. Currently, such changes are determined by repeatedly irradiating a specimen for a specified period of time in the Advanced Test Reactor (ATR) and then removing it from the reactor for evaluation. The labor and time to remove, examine, and return irradiated samples for each measurement makes this approach very expensive. In addition, such techniques provide limited data and may disturb the phenomena of interest. To resolve these issues, an instrumented creep testing capability is being developed for specimens irradiated in pressurized water reactor (PWR) coolant conditions in the ATR at the Idaho National Laboratory (INL). This paper reports the status of INL efforts to develop this testing capability. In addition to providing an overview of in-pile creep test capabilities available at other test reactors, this paper focuses on efforts to design and evaluate a prototype test rig in an autoclave at INL's High Temperature Test Laboratory (HTTL).

  17. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Surface preparation for residual stress measurement of an accelerated corrosion tested welded marine steel

    International Nuclear Information System (INIS)

    Ahmad, Bilal; Fitzpatrick, Michael E.

    2015-01-01

    Residual stress measurement is often required for the assessment of structural integrity of components. Measurement of residual stress in corrosion tested specimens is challenging owing to the difficulty of accessing the surface because of the rust layer. This study explored the potential methods for the surface preparation of an ultrasonically-peened and accelerated corrosion tested DH36 marine steel fillet welded specimen to ease the way for subsequent residual stress measurement using neutron diffraction and the contour method. We find that hydroblasting introduces compressive residual stress at the surface that will alter the surface stress to be measured

  20. A New Position Measurement System Using a Motion-Capture Camera for Wind Tunnel Tests

    Directory of Open Access Journals (Sweden)

    Yousok Kim

    2013-09-01

    Full Text Available Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS. The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape of the test specimen using system identification methods (frequency domain decomposition, FDD. By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape with the 3D measurements.

  1. Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

    Science.gov (United States)

    Vargas, Magda B.; Counter, Douglas

    2011-01-01

    Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

  2. Kettle test--a brief measure of cognitive functional performance. Reliability and valdity in stroke rehabilitation.

    Science.gov (United States)

    Hartman-Maeir, Adina; Harel, Hagit; Katz, Noomi

    2009-01-01

    We examined the reliability and validity of the Kettle Test, a brief performance measure based on a complex everyday task designed to tap into basic and higher level cognitive processes. Participants included 21 people attending stroke rehabilitation and 4 occupational therapists for the reliability analysis, 36 people at discharge from stroke rehabilitation, and 36 age-matched healthy control participants for the validity analyses. Instruments included a battery of conventional cognitive measures and functional outcomes. Interrater reliability was found to be high. Stroke survivors at discharge from rehabilitation were found to require significantly more assistance on the Kettle Test than control participants (p Kettle Test were significantly and moderately correlated with the conventional cognitive and functional outcome measures. The results support the reliability and validity of the Kettle Test as a top-down measure of cognition-in-function in people at discharge from stroke rehabilitation.

  3. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  4. Quantitative measurement of blood circulation in tests of rats using nuclear medical methods

    International Nuclear Information System (INIS)

    Ripke, R.

    1980-01-01

    The experiments show that is it is possible to quantitatively assess the blood circulation and, within limits, the germinative function of tests by measuring the impulses of an incorporated radionuclide (99-Tc-pertechnetate) using an uptake measuring instrument. This is a rapid and unbloody method to be adopted in human medicine. 'Acute tests' or pre-damaged tests can thus be exactly diagnosed. In the former case the circulation modification and in the latter the evaluation of the germinative function ability is of main interest. The most important measuring criterion is the 15-minute-uptake U; it represents the blood circulation in the tests measured. The germinative function ability is evaluated on the basis of the accumulation activity Nsub(max). (orig./MG) [de

  5. Measuring student learning using initial and final concept test in an STEM course

    Science.gov (United States)

    Kaw, Autar; Yalcin, Ali

    2012-06-01

    Effective assessment is a cornerstone in measuring student learning in higher education. For a course in Numerical Methods, a concept test was used as an assessment tool to measure student learning and its improvement during the course. The concept test comprised 16 multiple choice questions and was given in the beginning and end of the class for three semesters. Hake's gain index, a measure of learning gains from pre- to post-tests, of 0.36 to 0.41 were recorded. The validity and reliability of the concept test was checked via standard measures such as Cronbach's alpha, content and criterion-related validity, item characteristic curves and difficulty and discrimination indices. The performance of various subgroups such as pre-requisite grades, transfer students, gender and age were also studied.

  6. Indirect measurement of motivation: Developing and testing a motivational recoding-free implicit association test (m-IAT-RF)

    DEFF Research Database (Denmark)

    Kraus, Alexandra Anita; Scholderer, Joachim

    2015-01-01

    For the indirect measurement of approach-avoidance tendencies, two procedures are introduced and compared. The procedures are modifications of the standard IAT and the Recoding-Free IAT (IAT-RF) and use a motivational attribute dimension (approach, avoidance) instead of an evaluative one. Study 1...... (N = 162) assesses their convergent and discriminant validity with respect to self-reported measures of motivation and evaluation, and their predictive validity with respect to actual behavior. Study 2 (N = 205) furthermore compares their validity to evaluative variants of the same test paradigms...

  7. Safety measures for integrity test apparatus for IS process. Sulfuric acid decomposition section

    International Nuclear Information System (INIS)

    Noguchi, Hiroki; Kubo, Shinji; Iwatsuki, Jin; Onuki, Kaoru

    2013-07-01

    Hazardous substances such as sulfuric acid, sulfur dioxide and hydrogen iodide acid are employed in thermochemical Iodine-Sulfur (IS) process. It is necessary to take safety measure against workers and external environments to study experimentally on IS process. Presently we have been conducting to verify the soundness of main components made of engineering material in actual corrosive condition. An integrity test apparatus for the components of sulfuric acid decomposition was set up. We will use the hazardous substances such as sulfuric acid and sulfur dioxide and perform the experiment in pressurized condition in this integrity test. Safety measures for the test apparatus, operation and abnormal situation were considered prior to starting the test. This report summarized the consideration results for the safety measures on the integrity test apparatus for the components of sulfuric acid decomposition. (author)

  8. NIH Toolbox Cognition Battery (NIHTB-CB): list sorting test to measure working memory.

    Science.gov (United States)

    Tulsky, David S; Carlozzi, Noelle; Chiaravalloti, Nancy D; Beaumont, Jennifer L; Kisala, Pamela A; Mungas, Dan; Conway, Kevin; Gershon, Richard

    2014-07-01

    The List Sorting Working Memory Test was designed to assess working memory (WM) as part of the NIH Toolbox Cognition Battery. List Sorting is a sequencing task requiring children and adults to sort and sequence stimuli that are presented visually and auditorily. Validation data are presented for 268 participants ages 20 to 85 years. A subset of participants (N=89) was retested 7 to 21 days later. As expected, the List Sorting Test had moderately high correlations with other measures of working memory and executive functioning (convergent validity) but a low correlation with a test of receptive vocabulary (discriminant validity). Furthermore, List Sorting demonstrates expected changes over the age span and has excellent test-retest reliability. Collectively, these results provide initial support for the construct validity of the List Sorting Working Memory Measure as a measure of working memory. However, the relationship between the List Sorting Test and general executive function has yet to be determined.

  9. Automatic Test Bench for the Measurement of the Magnetic Interference on LVDTs

    CERN Document Server

    Spiezia, G; Masi, A; Pierno, A; Martino, M

    2010-01-01

    This paper proposes a rigorous and repeatable measurement procedure to analyze the effects of magnetic interferences on Linear Variable Differential Transformer sensors. This issue is neither addressed in the sensor datasheet, nor in the scientific literature. The potential of the method and the performance of an automated test bench, that implements the procedure, are proved by measuring the drift of the position reading due to external magnetic interferences on a commercial LVDT. Finally, the repeatability of the test bench is shown.

  10. Dripper testing: Application of statistical quality control for measurement system analysis

    Directory of Open Access Journals (Sweden)

    Hermes S. da Rocha

    Full Text Available ABSTRACT Laboratory tests for technical evaluation or irrigation material testing involve the measurement of many variables, as well as monitoring and control of test conditions. This study, carried out in 2016, aimed at using statistical quality control techniques to evaluate results of dripper tests. Exponentially weighted moving average control charts were elaborated, besides capability indices for the measurement of the test pressure and water temperature; and study on repeatability and reproducibility (Gage RR of flow measurement system using 10 replicates, in three work shifts (morning, afternoon and evening, with 25 emitters. Both the test pressure and water temperature remained stable, with “excellent” performance for the pressure adjustment process by integrative-derivative proportional controller. The variability between emitters was the component with highest contribution to the total variance of the flow measurements, with 96.77% of the total variance due to the variability between parts. The measurement system was classified as “acceptable” or “approved” by the Gage RR study; and non-random causes of significant variability were not identified in the routine of tests.

  11. Virtual test: A student-centered software to measure student's critical thinking on human disease

    Science.gov (United States)

    Rusyati, Lilit; Firman, Harry

    2016-02-01

    The study "Virtual Test: A Student-Centered Software to Measure Student's Critical Thinking on Human Disease" is descriptive research. The background is importance of computer-based test that use element and sub element of critical thinking. Aim of this study is development of multiple choices to measure critical thinking that made by student-centered software. Instruments to collect data are (1) construct validity sheet by expert judge (lecturer and medical doctor) and professional judge (science teacher); and (2) test legibility sheet by science teacher and junior high school student. Participants consisted of science teacher, lecturer, and medical doctor as validator; and the students as respondent. Result of this study are describe about characteristic of virtual test that use to measure student's critical thinking on human disease, analyze result of legibility test by students and science teachers, analyze result of expert judgment by science teachers and medical doctor, and analyze result of trial test of virtual test at junior high school. Generally, result analysis shown characteristic of multiple choices to measure critical thinking was made by eight elements and 26 sub elements that developed by Inch et al.; complete by relevant information; and have validity and reliability more than "enough". Furthermore, specific characteristic of multiple choices to measure critical thinking are information in form science comic, table, figure, article, and video; correct structure of language; add source of citation; and question can guide student to critical thinking logically.

  12. A Test-Bench for Measurement of Electrical Static Parameters of Strip Silicon Detectors

    CERN Document Server

    Golutvin, I A; Danilevich, V G; Dmitriev, A Yu; Elsha, V V; Zamiatin, Y I; Zubarev, E V; Ziaziulia, F E; Kozus, V I; Lomako, V M; Stepankov, D V; Khomich, A P; Shumeiko, N M; Cheremuhin, A E

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for measurement data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control.

  13. Transverse strength of railway tracks: part 2. Test system for ballast resistance in line measurement

    Directory of Open Access Journals (Sweden)

    Antonio De Iorio

    2014-10-01

    Full Text Available In the present paper, testing methods currently adopted to measure the in service ballast resistance are synthetically reviewed to identify the main sources of uncertainty influencing the test loads and to define an experimental methodology allowing the optimal control of the testing parameters without the introduction of spurious or parasitic actions on the track sample. An alternative testing system, which allows applying on a fullscale sample of a railway track testing loads very close the real ones, is presented. Of the new system, both the ways of use for measuring the transversal and axial ballast strength, the general procedure to carry out the experimentation and its application to a real scenario are described, highlighting its main advantages in terms both of modalities for applying the loads and of testing parameter control.

  14. An Evaluation of Standardized Tests as Tools for the Measurement of Language Development.

    Science.gov (United States)

    Roberts, Elsa

    Four tests--PPVT, ITPA, MRT, WPPSI--commonly used to measure language development in young children are evaluated by four criteria: (1) what development aspects do they claim to tap; (2) what do they actually tap; (3) what linguistic knowledge is presupposed; (4) what special problems face a non-standard English speaker. These tests are considered…

  15. The shuttle walk test: a new approach to functional walking capacity measurements for patients after stroke?

    NARCIS (Netherlands)

    Bloemendaal, M.; Kokkeler, A.M.; Port, I.G. van de

    2012-01-01

    OBJECTIVE: To determine the construct validity, test-retest reliability, and measurement error of the shuttle walk test (SWT) for patients after stroke. DESIGN: Clinimetric study. SETTING: Three rehabilitation centers in the Netherlands. PARTICIPANTS: A sample of patients after stroke (N=75; mean

  16. Development of the Flame Test Concept Inventory: Measuring Student Thinking about Atomic Emission

    Science.gov (United States)

    Bretz, Stacey Lowery; Murata Mayo, Ana Vasquez

    2018-01-01

    This study reports the development of a 19-item Flame Test Concept Inventory, an assessment tool to measure students' understanding of atomic emission. Fifty-two students enrolled in secondary and postsecondary chemistry courses were interviewed about atomic emission and explicitly asked to explain flame test demonstrations and energy level…

  17. Toward Intelligent Assessment: An Integration of Constructed Response Testing, Artificial Intelligence, and Model-Based Measurement.

    Science.gov (United States)

    Bennett, Randy Elliot

    A new assessment conception is described that integrates constructed-response testing, artificial intelligence, and model-based measurement. The conception incorporates complex constructed-response items for their potential to increase the validity, instructional utility, and credibility of standardized tests. Artificial intelligence methods are…

  18. Operational Testing and Measurement of the Resolving Time of a Counting Assembly

    International Nuclear Information System (INIS)

    Manent, G.; Scheemaecker, J. de

    1968-01-01

    An experiment is described which constitutes a very sensitive test of the satisfactory operation of a counting assembly. It makes it possible to measure the resolving time of an assembly to an accuracy of 1 per cent. A certain number of examples are presented which show the sensitivity of the test. (author) [fr

  19. Using Item Response Theory to Evaluate Measurement Precision of Selection Tests at the French Pilot Training

    NARCIS (Netherlands)

    Veldhuis, M.|info:eu-repo/dai/nl/338041869; Matton, N.; Vautier, S.

    2012-01-01

    In pilot selection settings, decisions are often based on cutoff scores. In item response theory the measurement precision of a test score can be evaluated by its degree of information. We investigated whether the maximum of test information corresponded to the cutoff zone for 10 cognitive ability

  20. [Test-retest reliability of the Implicit Association Test for measuring shyness: Inclusion of malleability of implicit shyness].

    Science.gov (United States)

    Fujii, Tsutomu; Sawaumi, Takafumi; Aikawa, Atsushi

    2015-10-01

    The Implicit Association Test of Shyness (Shyness IAT: Aikawa & Fujii, 2011) provides an indirect assessment of shyness by measuring associations of self (vs. other) with shyness-related (vs sociability-related) words. In this study we examined the test-retest reliability of the Shyness IAT. Thirty-five participants responded twice to the Shyness IAT with a time lag of one month. The correlation coefficient between the two time points was .54 (p = .001), confirming an adequate level of test-retest reliability. Indeed, changes in explicit and implicit shyness between the two time points were not related to sociable behavior during the one month period. Implications of the results for the assessment of personalities using IATs as well as relevant future directions are discussed.

  1. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    OpenAIRE

    Jared A. Frank; Anthony Brill; Vikram Kapila

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their em...

  2. Installation of a Devonian Shale Reservoir Testing Facility and acquisition of reservoir property measurements

    Energy Technology Data Exchange (ETDEWEB)

    Locke, C.D.; Salamy, S.P.

    1991-09-01

    In October, a contract was awarded for the Installation of a Devonian Shale Reservoir Testing Facility and Acquisition of Reservoir Property measurements from wells in the Michigan, Illinois, and Appalachian Basins. Geologic and engineering data collected through this project will provide a better understanding of the mechanisms and conditions controlling shale gas production. This report summarizes the results obtained from the various testing procedures used at each wellsite and the activities conducted at the Reservoir Testing Facility.

  3. Installation of a Devonian Shale Reservoir Testing Facility and acquisition of reservoir property measurements. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Locke, C.D.; Salamy, S.P.

    1991-09-01

    In October, a contract was awarded for the Installation of a Devonian Shale Reservoir Testing Facility and Acquisition of Reservoir Property measurements from wells in the Michigan, Illinois, and Appalachian Basins. Geologic and engineering data collected through this project will provide a better understanding of the mechanisms and conditions controlling shale gas production. This report summarizes the results obtained from the various testing procedures used at each wellsite and the activities conducted at the Reservoir Testing Facility.

  4. Development of multiple choice pictorial test for measuring the dimensions of knowledge

    Science.gov (United States)

    Nahadi, Siswaningsih, Wiwi; Erna

    2017-05-01

    This study aims to develop a multiple choice pictorial test as a tool to measure dimension of knowledge in chemical equilibrium subject. The method used is Research and Development and validation that was conducted in the preliminary studies and model development. The product is multiple choice pictorial test. The test was developed by 22 items and tested to 64 high school students in XII grade. The quality of test was determined by value of validity, reliability, difficulty index, discrimination power, and distractor effectiveness. The validity of test was determined by CVR calculation using 8 validators (4 university teachers and 4 high school teachers) with average CVR value 0,89. The reliability of test has very high category with value 0,87. Discrimination power of items with a very good category is 32%, 59% as good category, and 20% as sufficient category. This test has a varying level of difficulty, item with difficult category is 23%, the medium category is 50%, and the easy category is 27%. The distractor effectiveness of items with a very poor category is 1%, poor category is 1%, medium category is 4%, good category is 39%, and very good category is 55%. The dimension of knowledge that was measured consist of factual knowledge, conceptual knowledge, and procedural knowledge. Based on the questionnaire, students responded quite well to the developed test and most of the students like this kind of multiple choice pictorial test that include picture as evaluation tool compared to the naration tests was dominated by text.

  5. Testing Measurement Invariance of the Students' Affective Characteristics Model across Gender Sub-Groups

    Science.gov (United States)

    Demir, Ergül

    2017-01-01

    In this study, the aim was to construct a significant structural measurement model comparing students' affective characteristics with their mathematic achievement. According to this model, the aim was to test the measurement invariances between gender sub-groups hierarchically. This study was conducted as basic and descriptive research. Secondary…

  6. Indirect deformation (strain) measurements and calibrations in Sandia triaxial apparatus for rock testing to 2500C

    International Nuclear Information System (INIS)

    Wawersik, W.R.

    1979-09-01

    Indirect procedures for axial and radial strain measurements on rock in triaxial tests to 250 0 C are presented. The description of techniques includes discussions of all calibrations and of the accuracies of measurements. In addition, two examples are given to show how the techniques are implemented in triaxial compression and triaxial extension experiments. 10 figures

  7. Test-beam programs for devices to measure luminosity and energy ...

    Indian Academy of Sciences (India)

    tem studies for luminosity and energy measurements and beam diagnostics for luminosity optimization. Keywords. ... tional information is obtained from a calorimeter measuring e+e− pairs produced by beamstrahlung ... (left); A diamond sensor of 10 × 10 mm2 size and 300 µm thickness assembled for the test-beam (right).

  8. Test structures design considerations for RF-CV measurements on leaky dielectrics

    NARCIS (Netherlands)

    Schmitz, Jurriaan; Cubaynes, F.N.; Cubaynes, Florence N.; Havens, Ramon J.; de Kort, Randy; Scholten, Adries J.; Tiemeijer, Luuk F.

    2004-01-01

    We present an MOS capacitance-voltage measurement methodology that, contrary to present methods, is highly robust against gate leakage current densities up to 1000 A/cm/sup 2/. The methodology features specially designed RF test structures and RF measurement frequencies. It allows MOS parameter

  9. Test structure design considerations for RF-CV measurements on leaky dielectrics

    NARCIS (Netherlands)

    Schmitz, Jurriaan; Cubaynes, F.N; Cubaynes, F.N.; Havens, R.J.; de Kort, R.; Scholten, A.J.; Tiemeijer, L.F.

    2003-01-01

    We present a MOS capacitance-voltage measurement methodology that, contrary to present methods, is highly robust against gate leakage current densities up to 1000 A/cm/sup 2/. The methodology features specially designed RF test structures and RF measurement frequencies. It allows MOS parameter

  10. 10 CFR 431.444 - Test procedures for the measurement of energy efficiency.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures for the measurement of energy efficiency. 431.444 Section 431.444 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR... procedures for the measurement of energy efficiency. (a) Scope. Pursuant to section 346(b)(1) of EPCA, this...

  11. Comparing Graphical and Verbal Representations of Measurement Error in Test Score Reports

    Science.gov (United States)

    Zwick, Rebecca; Zapata-Rivera, Diego; Hegarty, Mary

    2014-01-01

    Research has shown that many educators do not understand the terminology or displays used in test score reports and that measurement error is a particularly challenging concept. We investigated graphical and verbal methods of representing measurement error associated with individual student scores. We created four alternative score reports, each…

  12. Calorimeter measures high nuclear heating rates and their gradients across a reactor test hole

    Science.gov (United States)

    Burwell, D.; Coombe, J. R.; Mc Bride, J.

    1970-01-01

    Pedestal-type calorimeter measures gamma-ray heating rates from 0.5 to 7.0 watts per gram of aluminum. Nuclear heating rate is a function of cylinder temperature change, measured by four chromel-alumel thermocouples attached to the calorimeter, and known thermoconductivity of the tested material.

  13. Alternate Form and Test-Retest Reliability of easyCBM Reading Measures. Technical Report # 0906

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2009-01-01

    We report the results of a test-retest and alternate form reliability study of grade 1, 3, 5, and 8 reading measures from the easyCBM assessment system. Approximately 50 students in each grade participated in the study. In Grade 1, we studied the following measures: Phoneme Segmenting, Letter Sounds, Letter Names, Word Reading Fluency, and Passage…

  14. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  15. Reliability of a test measuring transversus abdominis muscle recruitment with a pressure biofeedback unit.

    Science.gov (United States)

    von Garnier, Katharina; Köveker, Kirstin; Rackwitz, Berid; Kober, Ulrike; Wilke, Sabine; Ewert, Thomas; Stucki, Gerold

    2009-03-01

    There are indications that segmental stabilising exercises (SSEs) are effective in the treatment of low back pain. The evaluation of successful training in SSE performance in patients requires a reliable outcome measure. The PRONE test gives an indication of the activity of the transversus abdominis muscle. Performed in prone lying using a pressure biofeedback unit, it has been used as an aid to training and to assess the subject's ability to perform SSEs correctly. To evaluate inter-observer and test-retest reliability of the PRONE test. Repeated measures by three observers on 2 days. Department of Physical Medicine and Rehabilitation, Ludwig-Maximilian University, Munich, Germany. Forty nurses (39 females and one male), aged between 24 and 62 years, with at least one episode of low back pain. During the test, movement of the abdominal wall was monitored by measuring a change in pressure during muscle contraction termed 'abdominal hollowing'. Defined observation and palpation criteria were verified by the observers to ensure correct execution of the test. Participants were tested on two separate days. On the first day, Observer A performed two similar test sets, each with four exercises. On the second test day, Observers B and C conducted one test set each. This study found an intra-class correlation coefficient (ICC) of 0.47 [95% confidence interval (CI) 0.20 to 0.67] for inter-observer reliability, and an ICC of 0.81 (95% CI 0.67 to 0.90) for test-retest reliability. Kappa values and the limits of agreement were also calculated with similar results. For this subject group, the PRONE test had relatively low inter-observer reliability but, as may be expected, higher test-retest reliability. It is suggested that by providing visual feedback, the PRONE test may enhance patients' insight into their deep abdominal muscle recruitment and thereby increase their motivation to exercise.

  16. Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

    DEFF Research Database (Denmark)

    Diakos, Konstantinos; Wu, Qiuwei; Nielsen, Arne Hejde

    2014-01-01

    network to a more reliable, secure and economic operation. The implementation of these devices though, demands the warranty of a secure operation and high-accuracy performance. This paper describes the procedure of establishing a PMU (Phasor Measurement Unit)–PDC (Phasor Data Concentrator) platform...... that is able to derive and communicate synchrophasor measurements of different parts of the power network and the development of tests, according to IEEE standards, that evaluate the performance of PMUs and PDCs. The tests are created by using a Real Time Digital Simulation (RTDS) system. The results obtained...... from testing are analyzed to evaluate the performance of the devices....

  17. HASL measurements of fallout following the September 26, 1976 Chinese nuclear test

    International Nuclear Information System (INIS)

    1976-10-01

    Results are reported from measurements of radioactivity in the fallout from the nuclear test conducted by the Peoples Republic of China on September 26th, 1976. These measurements were carried on through Monday, October 18th. Results of these measurements made in New York and New Jersey, including external radiation exposure, air concentrations, deposition and the concentration of radioiodine in milk, are reported. An estimate of the thyroid dose from milk consumption is also included

  18. Response of HDR-VKL piping system to seismic test excitations: Comparison of analytical predictions and test measurements

    International Nuclear Information System (INIS)

    Srinivasan, M.G.; Kot, C.A.; Hsieh, B.J.

    1989-01-01

    As part of the earthquake investigations at the HDR (Heissdampfreaktor) Test Facility in Kahl/Main, FRG, simulated seismic tests (SHAM) were performed during April--May 1988 on the VKL (Versuchskreislauf) piping system. The purpose of these experiments was to study the behavior of piping subjected to a range of seismic excitation levels including those that exceed design levels manifold and that might induce failure of pipe supports or plasticity in the pipe runs, and to establish seismic margins for piping and pipe supports. Data obtained in the tests are also used to validate analysis methods. Detailed reports on the SHAM experiments are given elsewhere. The objective of this document is to evaluate a subsystem analysis module of the SMACS code. This module is a linear finite-element based program capable of calculating the response of nuclear power plant subsystems subjected to independent multiple-acceleration input excitation. The evaluation is based on a comparison of computational results of simulation of SHAM tests with corresponding test measurements

  19. A method for attitude measurement of a test vehicle based on the tracking of vectors

    International Nuclear Information System (INIS)

    Yang, Ning; Yang, Ming; Huo, Ju

    2015-01-01

    In the vehicle simulation test, in order to improve the measuring precision for the attitude of a test vehicle, a measuring method based on the vectors of light beams is presented, in which light beams are mounted on the test vehicle as the cooperation target, and the attitude of the test vehicle is calculated with the light beams’ vectors in the test vehicle’s coordinate system and the world coordinate system. Meanwhile, in order to expand the measuring range of the attitude parameters, cooperation targets and light beams in each cooperation target are increased. On this basis, the concept of an attitude calculation container is defined, and the selection method for the attitude calculation container that participates in the calculation is given. Simultaneously, the vectors of light beams are tracked so as to ensure the normal calculation of the attitude parameters. The experiments results show that this measuring method based on the tracking of vectors can achieve the high precision and wide range of measurement for the attitude of the test vehicle. (paper)

  20. A low cost imaging displacement measurement system for spacecraft thermal vacuum testing

    Science.gov (United States)

    Dempsey, Brian

    2006-01-01

    A low cost imaging displacement technique suitable for use in thermal vacuum testing was built and tested during thermal vacuum testing of the space infrared telescope facility (SIRTF, later renamed Spitzer infrared telescope facility). The problem was to measure the relative displacement of different portions of the spacecraft due to thermal expansion or contraction. Standard displacement measuring instrumentation could not be used because of the widely varying temperatures on the spacecraft and for fear of invalidating the thermal vacuum testing. The imaging system was conceived, designed, purchased, and installed in approximately 2 months at very low cost. The system performed beyond expectations proving that sub millimeter displacements could be measured from over 2 meters away. Using commercial optics it was possible to make displacement measurements down to 10 (mu)m. An automated image processing tool was used to process the data, which not only speeded up data reduction, but showed that velocities and accelerations could also be measured. Details of the design and capabilities of the system are discussed along with the results of the test on the observatory. Several images from the actual test are presented.

  1. Efficiency of Switch-Mode Power Audio Amplifiers - Test Signals and Measurement Techniques

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold; Andersen, Michael A. E.

    2016-01-01

    Switch-mode technology is greatly used for audio amplification. This is mainly due to the great efficiency this technology offers. Normally the efficiency of a switch-mode audio amplifier is measured using a sine wave input. However this paper shows that sine waves represent real audio very poorly....... An alternative signal is proposed for test purposes. The efficiency of a switch-mode power audio amplifier is modelled and measured with both sine wave and the proposed test signal as inputs. The results show that the choice of switching devices with low on resistances are unfairly favored when measuring...

  2. Actinide integral measurements in the CFRMF and integral tests for ENDF/B-V

    International Nuclear Information System (INIS)

    Anderl, R.A.

    1982-01-01

    Integral capture and/or fission rates have been reported earlier for several actinides irradiated in the fast neutron field of the Coupled Fast Reactivity Measurements Facility (CFRMF). These nuclides include 232 Th, 233 U, 235 U, 238 U, 237 Np, 239 Pu, 240 Pu, 242 Pu, 241 Am and 243 Am. This paper forucses on the utilization of these integral data for testing the respective cross sections on ENDF/B-V. Integral cross sections derived from the measured reaction rates are tabulated. Results are presented for cross-section data testing which includes integral testing based on a comparison of calculated and measured integral cross sections and testing based on least-squares-adjustment analyses

  3. Navigation Doppler Lidar Sensor for Precision Altitude and Vector Velocity Measurements Flight Test Results

    Science.gov (United States)

    Pierrottet, Diego F.; Lockhard, George; Amzajerdian, Farzin; Petway, Larry B.; Barnes, Bruce; Hines, Glenn D.

    2011-01-01

    An all fiber Navigation Doppler Lidar (NDL) system is under development at NASA Langley Research Center (LaRC) for precision descent and landing applications on planetary bodies. The sensor produces high resolution line of sight range, altitude above ground, ground relative attitude, and high precision velocity vector measurements. Previous helicopter flight test results demonstrated the NDL measurement concepts, including measurement precision, accuracies, and operational range. This paper discusses the results obtained from a recent campaign to test the improved sensor hardware, and various signal processing algorithms applicable to real-time processing. The NDL was mounted in an instrumentation pod aboard an Erickson Air-Crane helicopter and flown over vegetation free terrain. The sensor was one of several sensors tested in this field test by NASA?s Autonomous Landing and Hazard Avoidance Technology (ALHAT) project.

  4. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Catheter-based flow measurements in hemodialysis fistulas - Bench testing and clinical performance

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Lönn, Lars; Schroeder, Torben V

    2012-01-01

    Purpose: The purpose of this study was to perform bench and clinical testing of a catheter-based intravascular system capable of measuring blood flow in hemodialysis vascular accesses during endovascular procedures. Methods: We tested the Transonic ReoCath Flow Catheter System which uses...... the thermodilution method. A simulated vascular access model was constructed for the bench test. In total, 1960 measurements were conducted and the results were used to determine the accuracy and precision of the catheters, the effects of external factors (e.g., catheter placement, injection duration), and to test....... Blood flow measurements provide unique information on the hemodynamic status of a vascular access and have the potential to optimize results of interventions....

  6. A New Design of the Test Rig to Measure the Transmission Error of Automobile Gearbox

    Science.gov (United States)

    Hou, Yixuan; Zhou, Xiaoqin; He, Xiuzhi; Liu, Zufei; Liu, Qiang

    2017-12-01

    Noise and vibration affect the performance of automobile gearbox. And transmission error has been regarded as an important excitation source in gear system. Most of current research is focused on the measurement and analysis of single gear drive, and few investigations on the transmission error measurement in complete gearbox were conducted. In order to measure transmission error in a complete automobile gearbox, a kind of electrically closed test rig is developed. Based on the principle of modular design, the test rig can be used to test different types of gearbox by adding necessary modules. The test rig for front engine, rear-wheel-drive gearbox is constructed. And static and modal analysis methods are taken to verify the performance of a key component.

  7. Test-Retest Reliability of Common Measures of Eating Disorder Symptoms in Men Versus Women.

    Science.gov (United States)

    Forbush, Kelsie T; Hilderbrand, Lindsay A; Bohrer, Brittany K; Chapa, Danielle A N

    2017-04-01

    Approximately 10% to 30% of individuals with eating disorders (EDs) are male, yet because measures often have not been tested among male participants, it is unclear whether the psychometric properties of ED measures are equivalent between sexes. The purpose of this study was to compare the test-retest reliability of common ED measures in men versus women. Participants ( N = 227; 58.1% female) completed self-report measures of body dissatisfaction, restrained eating, disinhibited eating, bulimic symptoms, and desire-for-muscularity at baseline and 2-to-4 weeks later. Intraclass correlations were used to compute retest correlations. Spearman's rho was used to compute retest correlations for skewed and kurtotic variables. We compared 95% confidence intervals for intraclass correlation coefficients to determine whether measures differed in reliability between sexes. Most ED measures had at least acceptable test-retest reliabilities. However, few measures of disinhibited and binge eating demonstrated good reliability in men. Results highlight the utility of several ED measures for assessing symptom change over time, and the need for additional research to identify and correct for sources of gender unreliability among ED self-report measures in men-particularly for assessing constructs that include binge-eating behavior.

  8. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    Background: Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able...... to investigate the relationship between arch type and injury likelihood. Feiss Line is a valid clinical measure of the MLA. However, no study has investigated the reliability of the test. Objectives: The purpose was to describe a modified version of the Feiss Line test and to determine the intra- and inter......-tester reliability of this new foot alignment test. To emphasize the purpose of the modified test, the authors have named it The Navicular Position Test. Methods: Intra- and inter-tester reliability were evaluated of The Navicular Position Test with the use of ICC (interclass correlation coefficient) and Bland...

  9. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  10. Measuring seasonal variations of moisture in a landfill with the partitioning gas tracer test

    International Nuclear Information System (INIS)

    Han, Byunghyun; Jafarpour, Behnam; Gallagher, Victoria N.; Imhoff, Paul T.; Chiu, Pei C.; Fluman, Daniel A.

    2006-01-01

    Seven pilot-scale partitioning gas tracer tests (PGTTs) were conducted to assess the accuracy and reproducibility of this method for measuring water in municipal solid waste landfills. Tests were conducted in the same location over a 12-month period, and measured moisture conditions ranged from possible dry waste to refuse with a moisture content of 24.7%. The final moisture content of 24.7% was in reasonable agreement with gravimetric measurements of excavated refuse, where the moisture content was 26.5 ± 6.0CI%. Laboratory tests were used to assess the utility of the PGTT for measuring water in small pores, water sorbed to solid surfaces, and the influence of dry waste on PGTTs. These experiments indicated that when refuse surfaces are not completely solvated with water, PGTTs may produce misleading results (negative estimates) of water saturation and moisture content

  11. Non-destruction testing of natural stones by ultrasonic attenuation measurements

    International Nuclear Information System (INIS)

    Volkwein, A.

    1982-01-01

    As a basis for an intended nondestructive quality test of components made of natural stones an ultrasonic testing method was developed by which natural defects in the stone can be detected and localized. Selective fault detection by determination of sound velocity not being possible and tests by pulse echo method failing for most kinds of natural stones because of coarse grain, the investigations showed that an attenuation measurement in transmission technique will achieve the goal. For generation of transverse waves longitudinal search units were arranged in pairs underwater and directed on a plate of natural stone at a certain angle. As a measure for sound attenuation the amplitudes of the sound waves received were measured at different points on the plate. The bending tensile strengths of specimens from a plate gave a satisfying correlation with the ultrasonic attenuations measured before. (orig.) [de

  12. Optoelectronic measurement system for testing the optical parameters of infrared seeker

    Science.gov (United States)

    He, Wenjun; Liu, Zhiying; Fu, Yuegang

    2018-01-01

    We propose an optoelectronic measurement system for testing the optical parameters of infrared seeker, such as the position of the image plane, the size of the diffused spot, and the diameter of the scanning circle. The measurement method and operating principle of the optoelectronic measurement system have been introduced. The source of the stray light in the optoelectronic measurement system have been analyzed by using FRED software, and the stray light have been restricted effectively by a co-centered mica plate which closes to the substrate of pinhole. Experimental results show that the test error for the size of the diffused spot is less than +/-0.01 mm, the test errors for the position of the image plane and the diameter of the scanning circle are less than +/-0.02 mm.

  13. Charge measurement and mitigation for the main test masses of the GEO 600 gravitational wave observatory

    International Nuclear Information System (INIS)

    Hewitson, M; Danzmann, K; Grote, H; Hild, S; Hough, J; Lueck, H; Rowan, S; Smith, J R; Strain, K A; Willke, B

    2007-01-01

    Spurious charging of the test masses in gravitational wave interferometers is a well-known problem. Typically, concern arises due to the possibility of increased thermal noise due to a lowering of the quality factor of modes of the test-mass suspension, or due to the potential for increased displacement noise arising from charge migration on the surface of the test masses. Recent experience gained at the GEO 600 gravitational wave detector has highlighted an additional problem. GEO 600 uses electrostatic actuators to control the longitudinal position of the main test masses. The presence of charge on the test masses is shown to strongly affect the performance of the electrostatic actuators. This paper reports on a measurement scheme whereby the charge state of the GEO 600 test masses can be measured using the electrostatic actuators. The resulting measurements are expressed in terms of an effective bias voltage on the electrostatic actuators. We also describe attempts to remove the charge from the test masses and we show that the use of UV illumination was the most successful. Using UV illumination we were able to discharge and re-charge the test masses

  14. Ability and sex differences in spatial thinking: What does the mental rotation test really measure?

    Science.gov (United States)

    Hegarty, Mary

    2017-08-14

    Spatial ability tests are often interpreted as measuring facility with imagined spatial transformations of objects. But some spatial ability tests can be solved by analytic strategies as well as imagery transformation strategies. In the present study, participants gave verbal protocols while completing items on the Vandenberg and Kuse (Perceptual & Motor Skills, 4, 599-604, 1978) mental rotation test, and/or reported the strategies they had used on the test. Most participants used both imagery transformation and analytic strategies (i.e., feature-based, orientation-independent strategies) to solve the test items. Use of one analytic strategy, the global-shape strategy, was positively correlated with accuracy. Specifically, some of the most successful students used this strategy to eliminate answer choices, reducing the need for mental imagery. Men outperformed women, as is typical on this test, and were more likely than women to use the global-shape strategy, in particular, and more holistic strategies, in general. These results argue against the mental rotation test as a measure of spatial imagery alone and suggest that the ability to discover and use more efficient analytic strategies may be an important additional component of what this test measures.

  15. Measurements of Conversion Efficiency for a Flat Plate Thermophotovoltaic System Using a Photonic Cavity Test System

    International Nuclear Information System (INIS)

    Brown, E.J.; Ballinger, C.T.; Burger, S.R.; Charache, G.W.; Danielson, L.R.; DePoy, D.M.; Donovan, T.J.; LoCascio, M.

    2000-01-01

    The performance of a 1 cm 2 thermophotovoltaic (TPV) module was recently measured in a photonic cavity test system. A conversion efficiency of 11.7% was measured at a radiator temperature of 1076 C and a module temperature of 29.9 C. This experiment achieved the highest direct measurement of efficiency for an integrated TPV system. Efficiency was calculated from the ratio of the peak (load matched) electrical power output and the heat absorption rate. Measurements of these two parameters were made simultaneously to assure the validity of the measured efficiency value. This test was conducted in a photonic cavity which mimicked a typical flat-plate TPV system. The radiator was a large, flat graphite surface. The module was affixed to the top of a copper pedestal for heat absorption measurements. The heat absorption rate was proportional to the axial temperature gradient in the pedestal under steady-state conditions. The test was run in a vacuum to eliminate conductive and convective heat transfer mechanisms. The photonic cavity provides the optimal test environment for TPV efficiency measurements because it incorporates all important physical phenomena found in an integrated TPV system: high radiator emissivity and blackbody spectral shape, photon recycling, Lambertian distribution of incident radiation and complex geometric effects. Furthermore, the large aspect ratio between radiating surface area and radiator/module spacing produces a view factor approaching unity with minimal photon leakage

  16. Preliminary Validation of a New Measure of Negative Response Bias: The Temporal Memory Sequence Test.

    Science.gov (United States)

    Hegedish, Omer; Kivilis, Naama; Hoofien, Dan

    2015-01-01

    The Temporal Memory Sequence Test (TMST) is a new measure of negative response bias (NRB) that was developed to enrich the forced-choice paradigm. The TMST does not resemble the common structure of forced-choice tests and is presented as a temporal recall memory test. The validation sample consisted of 81 participants: 21 healthy control participants, 20 coached simulators, and 40 patients with acquired brain injury (ABI). The TMST had high reliability and significantly high positive correlations with the Test of Memory Malingering and Word Memory Test effort scales. Moreover, the TMST effort scales exhibited high negative correlations with the Glasgow Coma Scale, thus validating the previously reported association between probable malingering and mild traumatic brain injury. A suggested cutoff score yielded acceptable classification rates in the ABI group as well as in the simulator and control groups. The TMST appears to be a promising measure of NRB detection, with respectable rates of reliability and construct and criterion validity.

  17. Measurement of the UH-60A Hub Large Rotor Test Apparatus Control System Stiffness

    Science.gov (United States)

    Kufeld, Robert M.

    2014-01-01

    This purpose of this report is to provides details of the measurement of the control system stiffness of the UH-60A rotor hub mounted on the Large Rotor Test Apparatus (UH-60A/LRTA). The UH-60A/LRTA was used in the 40- by 80-Foot Wind Tunnel to complete the full-scale wind tunnel test portion of the NASA / ARMY UH-60A Airloads Program. This report describes the LRTA control system and highlights the differences between the LRTA and UH-60A aircraft. The test hardware, test setup, and test procedures are also described. Sample results are shown, including the azimuthal variation of the measured control system stiffness for three different loadings and two different dynamic actuator settings. Finally, the azimuthal stiffness is converted to fixed system values using multi-blade transformations for input to comprehensive rotorcraft prediction codes.

  18. Fault detection in multiply-redundant measurement systems via sequential testing

    International Nuclear Information System (INIS)

    Ray, A.

    1988-01-01

    The theory and application of a sequential test procedure for fault detection and isolation. The test procedure is suited for development of intelligent instrumentation in strategic processes like aircraft and nuclear plants where redundant measurements are usually available for individual critical variables. The test procedure consists of: (1) a generic redundancy management procedure which is essentially independent of the fault detection strategy and measurement noise statistics, and (2) a modified version of sequential probability ratio test algorithm for fault detection and isolation, which functions within the framework of this redundancy management procedure. The sequential test procedure is suitable for real-time applications using commercially available microcomputers and its efficacy has been verified by online fault detection in an operating nuclear reactor. 15 references

  19. The measurement test of uranium in a uranium-contaminated waste by passive gamma-rays measurement method

    CERN Document Server

    Sukegawa, Y; Ohki, K; Suzuki, S; Yoshida, M

    2002-01-01

    This report is completed about the measurement test and the proofreading of passive gamma - rays measurement method for Non - destructive assay of uranium in a uranium-contaminated waste. The following are the results of the test. 1) The estimation of the amount of uranium by ionization survey meter is difficult for low intensity of gamma-rays emitted from uranium under about 50g. 2) The estimation of the amount of uranium in the waste by NaI detector is possible in case of only uranium, but the estimation from mixed spectrums with transmission source (60-cobalt) is difficult to confirm target peaks. 3) If daughter nuclides of uranium and thorium chain of uranium ore exist, measurement by NaI detector is affected by gamma-rays from the daughter nuclides seriously-As a result, the estimation of the amount of uranium is difficult. 4) The measurement of uranium in a uranium-contaminated waste by germanium detector is possible to estimate of uranium and other nuclides. 5) As to estimation of the amount of uranium...

  20. Comparison of muscle/lean mass measurement methods: correlation with functional and biochemical testing.

    Science.gov (United States)

    Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N

    2018-03-01

    DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.

  1. Measurement protocols for performance testing of dosimetry services for external radiations

    International Nuclear Information System (INIS)

    1993-01-01

    In the Health and Safety Executive's ''Requirements for the Approval of Dosimetry Services under the Ionising Radiations Regulations 1985'', it is stipulated that dosimetry services seeking approval must show that they have successfully completed a performance test. The services must arrange for the tests to be carried out on application and thereafter every 18 months, by a laboratory which has received accreditation from the National Measurement Accreditation Service (NAMAS) for the whole performance testing activity. The performance tests must be carried out to published protocols and the purpose here is to provide protocols for external, whole body film and TLD dosimetry services, and for skin and extremity dosimetry services. (Author)

  2. Practical Testing and Performance Analysis of Phasor Measurement Unit Using Real Time Digital Simulator (RTDS)

    DEFF Research Database (Denmark)

    Liu, Leo; Rather, Zakir Hussain; Stearn, Nathen

    2012-01-01

    visualisation and post event analysis of power systems. It is expected however, that through integration with traditional Supervisory Control and Data Acquisition (SCADA) systems, closed loop control applications will be possible. Phasor Measurement Units (PMUs) are fundamental components of WAMS. Large WAMS...... for the testing of PMUs [2] there is a lack of specialised test equipment for performing such testing efficiently [3]. In this paper, RTDS based steady state and dynamic testing of the ALSTOM MiCOM P847 PMU using hardware in the loop is demonstrated. A correction algorithm supported by promising results is also...

  3. Development and testing of highway storm-sewer flow measurement and recording system

    Science.gov (United States)

    Kilpatrick, F.A.; Kaehrle, W.R.; Hardee, Jack; Cordes, E.H.; Landers, M.N.

    1985-01-01

    A comprehensive study and development of measuring instruments and techniques for measuring all components of flow in a storm-sewer drainage system was undertaken by the U.S. Geological Survey under the sponsorship of the Federal Highway Administration. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, electromagnetic velocity meters as well as the development and calibration of pneumatic-bubbler pressure transducer head measuring systems. Tracer-dilution and acoustic flow meter measurements were used in field verification tests. A single micrologger was used to record data from all the above instruments as well as from a tipping-bucket rain gage and also to activate on command the electromagnetic velocity meter and tracer-dilution systems. (Author 's abstract)

  4. Development of an item bank for computerized adaptive test (CAT) measurement of pain

    DEFF Research Database (Denmark)

    Petersen, Morten Aa.; Aaronson, Neil K; Chie, Wei-Chu

    2016-01-01

    by the EORTC QLQ-C30 questionnaire. METHODS: The development process consisted of four steps: (1) literature search, (2) formulation of new items and expert evaluations, (3) pretesting and (4) field-testing and psychometric analyses for the final selection of items. RESULTS: In step 1, we identified 337 pain....... CONCLUSIONS: We have established an item bank of 16 items suitable for CAT measurement of pain. While being backward compatible with the QLQ-C30, the new item bank will significantly improve measurement precision of pain. We recommend initiating CAT measurement by screening for pain using the two original QLQ......PURPOSE: Patient-reported outcomes should ideally be adapted to the individual patient while maintaining comparability of scores across patients. This is achievable using computerized adaptive testing (CAT). The aim here was to develop an item bank for CAT measurement of the pain domain as measured...

  5. Measurement and analysis to DIW of chassis dynamometers for automobile emissions testing

    Science.gov (United States)

    Zhu, Weimin; Wang, Dayong; Qi, Fang; Yang, Dengcai

    2010-12-01

    DIW (Dynamometer Inertia Weight) of 'chassis dynamometers for automobile emissions testing' is a total inertia weight of all rotating components in the chassis dynamometer. Total Inertia weight is a inertia device simulates translational and rotational kinetic energy of a traveling vehicle which is equivalent to the mass of the car. DIW is an important technical indicator, whether it is accurate or not will affect the calibration of all technical characteristics of 'chassis dynamometers for automobile emissions testing'. In this paper,first of all, we introduce a new method to measure the Dynamometer Inertia Weight, that is, coast-down testing with twice constant-force loading method, and we derivate a formula to calculate the Dynamometer Inertia Weight from kinetic energy conservation law. Secondly, we have done a lot of coast-down testings with twice constant-force load method. After analyzing the data, we found out the factors that affect the testing processes and the accuracy of testing results. Finally, after comparing twice constant-force loading method with the take-down flywheel method and twice constant-power loading method, we know that this coast-down testing with twice constant-force loading method is better than other methods in stability and repeatability and testing data will be more accurate. It's a accurate and convenient way to measure the DIW of 'chassis dynamometers for automobile emissions testing'.

  6. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds †

    Science.gov (United States)

    Frank, Jared A.; Brill, Anthony; Kapila, Vikram

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability. PMID:27556464

  7. Testing digital safety system software with a testability measure based on a software fault tree

    International Nuclear Information System (INIS)

    Sohn, Se Do; Hyun Seong, Poong

    2006-01-01

    Using predeveloped software, a digital safety system is designed that meets the quality standards of a safety system. To demonstrate the quality, the design process and operating history of the product are reviewed along with configuration management practices. The application software of the safety system is developed in accordance with the planned life cycle. Testing, which is a major phase that takes a significant time in the overall life cycle, can be optimized if the testability of the software can be evaluated. The proposed testability measure of the software is based on the entropy of the importance of basic statements and the failure probability from a software fault tree. To calculate testability, a fault tree is used in the analysis of a source code. With a quantitative measure of testability, testing can be optimized. The proposed testability can also be used to demonstrate whether the test cases based on uniform partitions, such as branch coverage criteria, result in homogeneous partitions that is known to be more effective than random testing. In this paper, the testability measure is calculated for the modules of a nuclear power plant's safety software. The module testing with branch coverage criteria required fewer test cases if the module has higher testability. The result shows that the testability measure can be used to evaluate whether partitions have homogeneous characteristics

  8. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    Directory of Open Access Journals (Sweden)

    Jared A. Frank

    2016-08-01

    Full Text Available Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  9. Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretchedwire RF measurements

    CERN Document Server

    Silvia Zorzetti, Silvia; Galindo Muño, Natalia; Wendt, Manfred

    2015-01-01

    The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-m regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method.

  10. Testing the algorithms for automatic identification of errors on the measured quantities of the nuclear power plant. Verification tests

    International Nuclear Information System (INIS)

    Svatek, J.

    1999-12-01

    During the development and implementation of supporting software for the control room and emergency control centre at the Dukovany nuclear power plant it appeared necessary to validate the input quantities in order to assure operating reliability of the software tools. Therefore, the development of software for validation of the measured quantities of the plant data sources was initiated, and the software had to be debugged and verified. The report contains the proposal for and description of the verification tests for testing the algorithms of automatic identification of errors on the observed quantities of the NPP by means of homemade validation software. In particular, the algorithms treated serve the validation of the hot leg temperature at primary circuit loop no. 2 or 4 at the Dukovany-2 reactor unit using data from the URAN and VK3 information systems, recorded during 3 different days. (author)

  11. Ares I-X Launch Vehicle Modal Test Measurements and Data Quality Assessments

    Science.gov (United States)

    Templeton, Justin D.; Buehrle, Ralph D.; Gaspar, James L.; Parks, Russell A.; Lazor, Daniel R.

    2010-01-01

    The Ares I-X modal test program consisted of three modal tests conducted at the Vehicle Assembly Building at NASA s Kennedy Space Center. The first test was performed on the 71-foot 53,000-pound top segment of the Ares I-X launch vehicle known as Super Stack 5 and the second test was performed on the 66-foot 146,000- pound middle segment known as Super Stack 1. For these tests, two 250 lb-peak electro-dynamic shakers were used to excite bending and shell modes with the test articles resting on the floor. The third modal test was performed on the 327-foot 1,800,000-pound Ares I-X launch vehicle mounted to the Mobile Launcher Platform. The excitation for this test consisted of four 1000+ lb-peak hydraulic shakers arranged to excite the vehicle s cantilevered bending modes. Because the frequencies of interest for these modal tests ranged from 0.02 to 30 Hz, high sensitivity capacitive accelerometers were used. Excitation techniques included impact, burst random, pure random, and force controlled sine sweep. This paper provides the test details for the companion papers covering the Ares I-X finite element model calibration process. Topics to be discussed include test setups, procedures, measurements, data quality assessments, and consistency of modal parameter estimates.

  12. The physical interpretation of the parameters measured during the tensile testing of materials at elevated temperatures

    International Nuclear Information System (INIS)

    Burton, B.

    1984-01-01

    Hot tensile (or compression) testing, where the stress developed in a material is measured under an imposed strain rate, is often used as an alternative to conventional creep testing. The advantages of the hot tensile test are that its duration can be more closely controlled by the experimenter and also that the technique is more convenient, since high precision testing machines are available. The main disadvantage is that the interpretation of results is more complex. The present paper relates the parameters which are measured in hot tensile tests, to physical processes which occur in materials deforming by a variety of mechanisms. For cases where no significant structural changes occur, as in viscous or superplastic flow, analytical expressions are derived which relate the stresses measured in these tests to material constants. When deformation is controlled by recovery processes, account has to be taken of the structural changes which occur concurrently. A wide variety of behaviour may then be exhibited which depends on the initial dislocation density, the presence of second-phase particles and the relative values of the recovery rate parameters and the velocity imposed by the testing machine. Numerical examples are provided for simple recovery models. (author)

  13. A test-bench for measurement of electrical static parameters of strip silicon detectors

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Dmitriev, A.Yu.; Elsha, V.V.

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control. (author)

  14. Measuring social health in the patient-reported outcomes measurement information system (PROMIS): item bank development and testing.

    Science.gov (United States)

    Hahn, Elizabeth A; Devellis, Robert F; Bode, Rita K; Garcia, Sofia F; Castel, Liana D; Eisen, Susan V; Bosworth, Hayden B; Heinemann, Allen W; Rothrock, Nan; Cella, David

    2010-09-01

    To develop a social health measurement framework, to test items in diverse populations and to develop item response theory (IRT) item banks. A literature review guided framework development of Social Function and Social Relationships sub-domains. Items were revised based on patient feedback, and Social Function items were field-tested. Analyses included exploratory factor analysis (EFA), confirmatory factor analysis (CFA), two-parameter IRT modeling and evaluation of differential item functioning (DIF). The analytic sample included 956 general population respondents who answered 56 Ability to Participate and 56 Satisfaction with Participation items. EFA and CFA identified three Ability to Participate sub-domains. However, because of positive and negative wording, and content redundancy, many items did not fit the IRT model, so item banks do not yet exist. EFA, CFA and IRT identified two preliminary Satisfaction item banks. One item exhibited trivial age DIF. After extensive item preparation and review, EFA-, CFA- and IRT-guided item banks help provide increased measurement precision and flexibility. Two Satisfaction short forms are available for use in research and clinical practice. This initial validation study resulted in revised item pools that are currently undergoing testing in new clinical samples and populations.

  15. Beyond relevance and recall: testing new user-centred measures of database performance.

    Science.gov (United States)

    Stokes, Peter; Foster, Allen; Urquhart, Christine

    2009-09-01

    Measures of the effectiveness of databases have traditionally focused on recall, precision, with some debate on how relevance can be assessed, and by whom. New measures of database performance are required when users are familiar with search engines, and expect full text availability. This research ascertained which of four bibliographic databases (BNI, CINAHL, MEDLINE and EMBASE) could be considered most useful to nursing and midwifery students searching for information for an undergraduate dissertation. Searches on title were performed for dissertation topics supplied by nursing students (n = 9), who made the relevance judgements. Measures of recall and precision were combined with additional factors to provide measures of effectiveness, while efficiency combined measures of novelty and originality and accessibility combined measures for availability and retrievability, based on obtainability. There were significant differences among the databases in precision, originality and availability, but other differences were not significant (Friedman test). Odds ratio tests indicated that BNI, followed by CINAHL were the most effective, CINAHL the most efficient, and BNI the most accessible. The methodology could help library services in purchase decisions as the measure for accessibility, and odds ratio testing helped to differentiate database performance.

  16. Design and test of voltage and current probes for EAST ICRF antenna impedance measurement

    Science.gov (United States)

    Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG

    2018-04-01

    On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L data for calculation under H-mode cases in EAST experiments.

  17. Measurement invariance of the Eating Attitudes Test-26 in Caucasian and Hispanic women.

    Science.gov (United States)

    Belon, Katherine E; Smith, Jane Ellen; Bryan, Angela D; Lash, Denise N; Winn, Jaime L; Gianini, Loren M

    2011-12-01

    To determine whether the EAT-26 functions similarly in Caucasian and Hispanic samples, the current study investigated the factor structure of the Eating Attitudes Test (EAT-26) in 235 undergraduate Caucasian (53.6%) and Hispanic (46.4%) women, and tested for measurement invariance across the two samples. A Confirmatory Factor Analysis (CFA) of the original 3-factor structure of the EAT resulted in a poor fit in both the Caucasian and Hispanic samples. We then performed a CFA using a previously discovered 4-factor, 16-item structure. This abbreviated measure was a good fit in both the Caucasian and Hispanic samples, and the model was invariant across all dimensions tested. The 16-item EAT is a better-fitting measure in Caucasian and Hispanic women than the commonly used EAT-26. This replicates an earlier finding and generalizes those conclusions to a Hispanic sample. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Test data from small solid propellant rocket motor plume measurements (FA-21)

    Science.gov (United States)

    Hair, L. M.; Somers, R. E.

    1976-01-01

    A program is described for obtaining a reliable, parametric set of measurements in the exhaust plumes of solid propellant rocket motors. Plume measurements included pressures, temperatures, forces, heat transfer rates, particle sampling, and high-speed movies. Approximately 210,000 digital data points and 15,000 movie frames were acquired. Measurements were made at points in the plumes via rake-mounted probes, and on the surface of a large plate impinged by the exhaust plume. Parametric variations were made in pressure altitude, propellant aluminum loading, impinged plate incidence angle and distance from nozzle exit to plate or rake. Reliability was incorporated by continual use of repeat runs. The test setup of the various hardware items is described along with an account of test procedures. Test results and data accuracy are discussed. Format of the data presentation is detailed. Complete data are included in the appendix.

  19. Concurrent validity of clinical tests for measuring hamstring flexibility in school age children.

    Science.gov (United States)

    Muyor, J M; Zemková, E; Štefániková, G; Kotyra, M

    2014-07-01

    The objectives were 1) to evaluate the hamstring muscle flexibility in children and adolescents; 2) to examine the relative contribution of the spinal curvatures, pelvic tilt and hamstring flexibility on the sit-and-reach (SR) score; and 3) to determine the validity of the sit-and-reach test through both active and passive hip flexion tests. 118 children and adolescents (aged 7-18 years; 60 males and 58 females) were tested for sit-and-reach (SR), passive straight leg raise (PSLR) and active straight leg raise (ASLR). The spinal curvatures and pelvic tilt were assessed during the SR test by means of the Spinal Mouse system. Females showed a statistically greater anterior pelvic tilt, distance reached in the SR test and hip flexion in both PSLR and ASLR tests than males. The pelvic tilt independently explained more than 60% of the variance (distance reached in the SR test) and in conjunction with lumbar flexion explained more than 80% of the variance. In conclusion, the pelvic tilt is the main determinant of SR test in school age children. The SR test can be considered an appropriate and valid test for evaluating pelvic tilt and lumbar flexion in school age children, but not to measure hamstring flexibility. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Evaluation and development of measurement components for a catalytic converter test system

    Energy Technology Data Exchange (ETDEWEB)

    Chan, A.K.

    1997-08-01

    The purpose of this research and development project was to evaluate and configure the components of a test system designed for the analysis of full-scale vehicle-aged automobile catalytic converters. The components tested included an exhaust gas analyzer for measuring hydrocarbon, CO, CO{sub 2} and O{sub 2} contents and a chemiluminescence detector (CLD) for measuring NO{sub x}, as well as thermocouples and pressure meters. A software package (TestPoint vers.2.Ob, Capital Equipment) was used to develop a computer-based data sampling and acquisition interface with the components and sensors connected to the test system. Tests of the Sun MGA-1200, a non-dispersive infrared (NDIR) analyzer, with CO, CO{sub 2} and various hydrocarbons (propane and octane) revealed sensitivity to large pressure changes (greater than 500 mbar). There was no significant cross-sensitivity between the gases except for the slight response of the hydrocarbon (HC) register to water vapor and CO. However, the low range of HC(5-30 vppm) expected in car exhaust after the converter means any cross-sensitivity could have an effect on the measurement, depending on measurement conditions. Tests of the EcoPhysics CLD 700 NO{sub x} meter also indicated sensitivity to pressure. An executable TestPoint run-time application was created to allow near real-time monitoring of the test system using a desktop computer. Nine channels of analog data are fed to a desktop computer via an A/D board and seven exhaust gas parameters through an RS-232C interface with the MGA-1200 23 refs, 32 figs, 10 tabs. Examination paper

  1. A Complete Characterization of Potential Compensation Tests of Hicksian Welfare Measures

    OpenAIRE

    Donald Keenan; Arthur Snow

    1999-01-01

    In this paper, the authors present complete characterizations of the compensation tests for potential Pareto superiority proposed by Kaldor, Hicks, and Samuelson in terms of the aggregate Hicksian measures of income compensation, including compensating and equivalent variations. The key to obtaining these characterizations lies in recognizing that each potential compensation test entails a search over possible outcomes, rather than a comparison of only the new and original outcomes, as with s...

  2. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able to investigate...... the relationship between arch type and injury likelihood. Feiss Line is a valid clinical measure of the MLA. However, no study has investigated the reliability of the test....

  3. Identification of characteristic frequencies of damaged railway tracks using field hammer test measurements

    Science.gov (United States)

    Oregui, M.; Li, Z.; Dollevoet, R.

    2015-03-01

    In this paper, the feasibility of the Frequency Response Function (FRF)-based statistical method to identify the characteristic frequencies of railway track defects is studied. The method compares a damaged track state to a healthy state based on non-destructive field hammer test measurements. First, a study is carried out to investigate the repeatability of hammer tests in railway tracks. By changing the excitation and measurement locations it is shown that the variability introduced by the test process is negligible. Second, following the concepts of control charts employed in process monitoring, a method to define an approximate healthy state is introduced by using hammer test measurements at locations without visual damage. Then, the feasibility study includes an investigation into squats (i.e. a major type of rail surface defect) of varying severity. The identified frequency ranges related to squats agree with those found in an extensively validated vehicle-borne detection system. Therefore, the FRF-based statistical method in combination with the non-destructive hammer test measurements has the potential to be employed to identify the characteristic frequencies of damaged conditions in railway tracks in the frequency range of 300-3000 Hz.

  4. The shuttle walk test: a new approach to functional walking capacity measurements for patients after stroke?

    Science.gov (United States)

    van Bloemendaal, Maijke; Kokkeler, Astrid M; van de Port, Ingrid G

    2012-01-01

    To determine the construct validity, test-retest reliability, and measurement error of the shuttle walk test (SWT) for patients after stroke. Clinimetric study. Three rehabilitation centers in the Netherlands. A sample of patients after stroke (N=75; mean age ± SD, 58.8±9.8y) who are capable of walking without physical assistance. Patients were excluded if they had sustained a subarachnoid hemorrhage or a stroke in the cerebellum or brainstem, or had any other conditions that limited their walking capacity more than the current stroke, or had sensory aphasia. Not applicable. Construct validity (6-minute walk test [6MWT]) and test-retest reliability of the SWT were assessed. Measurement error was determined with the standard error of measurement (SEM), limits of agreement, and smallest detectable differences (SDDs). Construct validity was confirmed by high significant correlations (r(p)≥.65, Pwalking distance in favor of the 6MWT. Test-retest reliability was good (intraclass correlation coefficient model 2,1 [ICC(2,1)]=.961 [.936-.977]). SEM was 6.0%, and the SDDs for individual and group were 302.0m (37%) and 38.7m (5%), respectively. The SWT is a valid and reliable measure and therefore a feasible instrument to determine functional walking capacity of patients after stroke, especially in high-speed walkers. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. The corrosion rate of copper in a bentonite test package measured with electric resistance sensors

    Energy Technology Data Exchange (ETDEWEB)

    Rosborg, Bo [Division of Surface and Corrosion Science, KTH, Stockholm (Sweden); Kosec, Tadeja; Kranjc, Andrej; Kuhar, Viljem; Legat, Andraz [Slovenian National Building and Civil Engineering Institute, Ljubljana (Slovenia)

    2012-12-15

    LOT1 test parcel A2 was exposed for six years in the Aespoe Hard Rock Laboratory, which offers a realistic environment for the conditions that will prevail in a deep repository for high-level radioactive waste disposal in Sweden. The test parcel contained copper electrodes for real-time corrosion monitoring in bentonite ring 36, where the temperature was 24 deg C, and copper coupons in bentonite rings 22 and 30, where the temperature was higher. After retrieval of the test parcel in January 2006, a bentonite test package consisting of bentonite rings 35 - 37 was placed in a container and sealed with a thick layer of paraffin. Later the same year new copper electrodes were installed in the test package. In January 2007 electric resistance (ER) sensors of pure copper with a thickness of 35 {mu}m were also installed in the test package mainly to facilitate the interpretation of the results from the real-time corrosion monitoring with electrochemical techniques. The ER measurements have shown that the corrosion rate of pure copper exposed in an oxic bentonite/ saline groundwater environment at room temperate decreases slowly with time to low but measurable values. The corrosion rates estimated from the regularly performed EIS measurements replicate the ER data. Thus, for this oxic environment in which copper acquires corrosion potentials of the order of 200 mV (SHE) or higher, electrochemical measurements provide believable data. Comparing the recorded ER data with an estimate of the average corrosion rate based on comparing cross-sections from exposed and protected sensor elements, it is obvious that the former overestimates the actual corrosion rate, which is understandable. It seems as if electrochemical measurements can provide a better estimate of the corrosion rate; however, this is quite dependent on the use of proper measuring frequencies and evaluation methods. In this respect ER measurements are more reliable. It has been shown that real-time corrosion

  6. Case studies on the impact of poor traceability in testing and measurement

    CSIR Research Space (South Africa)

    Marais, EL

    2006-01-01

    Full Text Available -2142 Wingate Park 0153 Pretoria Telephone: +27(12) 349 1500 Fax: +27 (12) 349 1501 Email: maggier@nla.org.za Internet: http://www.nla.org.za 2006 Test and Measurement Conference Case Studies on the Impact of Poor Traceability in Testing... and Measurement Speaker / Author: E.L. Marais Co-authors: E.P. Tarnow, S.B. Sidney CSIR National Metrology Laboratory PO Box 395, Pretoria, 0001, South Africa Email: elmarais@csir.co.za Phone: 012 841 3013 Fax: 012 841 2131 Abstract The importance...

  7. Obsessiveness and a thematic apperception test-based measure of aggression.

    Science.gov (United States)

    Cogan, Rosemary; Ashford, Daniel; Chaney, Brett; Embry, Sheena; Emory, Lindsay; Goebel, Holly; Holstrom, Nicole; Keithley, David; Lawson, Miranda; Mcpherson, Joe; Scott, Brandon; Tebbets, Jomie

    2004-12-01

    Freud (1909/1955) hypothesized a conflict between love and hate in obsessive neurosis. To test this relationship, we compared a Thematic Apperception Test-based measure of aggressive fantasies in college men who scored either high or low on the Obsessive-Compulsive Inventory-Revised. 64 undergraduate men from beginning classes in psychology participated. Their mean age was 19.4 yr. (SD= 1.7). 16 men with high scores had significantly higher scores on a TAT-based measure of aggressive fantasies toward parents, partners, and others than 15 men with low scores, which is consistent with Freud's hypothesis.

  8. Subcritical Measurements Research Program for Fresh and Spent Materials Test Reactor Fuels

    International Nuclear Information System (INIS)

    Blanchard, A.

    1999-01-01

    'A series of subcritical noise measurements were performed on fresh and spent University of Missouri Research Reactor fuel assemblies. These experimental measurements were performed for the purposes of providing benchmark quality data for validating transport theory computer codes and nuclear cross-section data used to perform criticality safety analyses for highly enriched, uranium-aluminum Material Test Reactor fuel assemblies. A mechanical test rig was designed and built to hold up to four fuel assemblies and neutron detectors in a subcritical array. The rig provided researchers with the ability to evaluate the reactivity effects of variable fuel/detector spacing, fuel rotation, and insertion of metal reflector plates into the lattice.'

  9. Field Measurements of Perceived Air Quality in the Test-Bed for Innovative Climate Conditioning Technologies

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Kabrhel, Michal

    the potential influence of aforementioned technologies on the perceived air quality. Additionally, the effect of Demand Controlled Ventilation (DCV) on the perceived air quality was tested. Measurements comprised of the assessments of perceived air quality and objective measurements of operative temperature......, relative humidity and CO2 concentration. Results showed that the mean sensory pollution load in the tested offices was 0.09±0.02 olf/m2 (mean±SEM). This refers to a low-polluting building according to CEN Report CR 1752. The acceptability of the air quality was worst in unoccupied offices ventilated at 20...

  10. Multifactorial assessment of measurement errors affecting intraoral quantitative sensory testing reliability.

    Science.gov (United States)

    Moana-Filho, Estephan J; Alonso, Aurelio A; Kapos, Flavia P; Leon-Salazar, Vladimir; Durand, Scott H; Hodges, James S; Nixdorf, Donald R

    2017-07-01

    Measurement error of intraoral quantitative sensory testing (QST) has been assessed using traditional methods for reliability, such as intraclass correlation coefficients (ICCs). Most studies reporting QST reliability focused on assessing one source of measurement error at a time, e.g., inter- or intra-examiner (test-retest) reliabilities and employed two examiners to test inter-examiner reliability. The present study used a complex design with multiple examiners with the aim of assessing the reliability of intraoral QST taking account of multiple sources of error simultaneously. Four examiners of varied experience assessed 12 healthy participants in two visits separated by 48h. Seven QST procedures to determine sensory thresholds were used: cold detection (CDT), warmth detection (WDT), cold pain (CPT), heat pain (HPT), mechanical detection (MDT), mechanical pain (MPT) and pressure pain (PPT). Mixed linear models were used to estimate variance components for reliability assessment; dependability coefficients were used to simulate alternative test scenarios. Most intraoral QST variability arose from differences between participants (8.8-30.5%), differences between visits within participant (4.6-52.8%), and error (13.3-28.3%). For QST procedures other than CDT and MDT, increasing the number of visits with a single examiner performing the procedures would lead to improved dependability (dependability coefficient ranges: single visit, four examiners=0.12-0.54; four visits, single examiner=0.27-0.68). A wide range of reliabilities for QST procedures, as measured by ICCs, was noted for inter- (0.39-0.80) and intra-examiner (0.10-0.62) variation. Reliability of sensory testing can be better assessed by measuring multiple sources of error simultaneously instead of focusing on one source at a time. In experimental settings, large numbers of participants are needed to obtain accurate estimates of treatment effects based on QST measurements. This is different from clinical

  11. FY 2016 Status Report: CIRFT Testing Data Analyses and Updated Curvature Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-08-01

    This report provides a detailed description of FY15 test result corrections/analysis based on the FY16 Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) test program methodology update used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal transportation conditions. The CIRFT consists of a U-frame testing setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages to a universal testing machine. The curvature of rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are used and clamped to the side connecting plates of the U-frame to capture the deformation of the rod. The contact-based measurement, or three-LVDT-based curvature measurement system, on SNF rods has been proven to be quite reliable in CIRFT testing. However, how the LVDT head contacts the SNF rod may have a significant effect on the curvature measurement, depending on the magnitude and direction of rod curvature. It has been demonstrated that the contact/curvature issues can be corrected by using a correction on the sensor spacing. The sensor spacing defines the separation of the three LVDT probes and is a critical quantity in calculating the rod curvature once the deflections are obtained. The sensor spacing correction can be determined by using chisel-type probes. The method has been critically examined this year and has been shown to be difficult to implement in a hot cell environment, and thus cannot be implemented effectively. A correction based on the proposed equivalent gauge-length has the required flexibility and accuracy and can be appropriately used as a correction factor. The correction method based on the equivalent gauge length has been successfully demonstrated in CIRFT data analysis for the dynamic tests conducted on Limerick (LMK) (17 tests), North Anna (NA) (6 tests), and Catawba mixed oxide (MOX

  12. Estimation of uncertainty of laser interferometer measurement in industrial robot accuracy tests

    Directory of Open Access Journals (Sweden)

    Józwik Jerzy

    2017-01-01

    Full Text Available The subject of this article is the assessment of measurement uncertainty of the Renishaw XL80 laser interferometer in MOTOMAN HP20 industrial robot inaccuracy test. The paper presents the methodology for estimating the measurement uncertainty of the system used in tests. Estimates of standard and extended uncertainty were calculated for the given research method. These uncertainties are based on the information included in the device calibration certificate (method B but also on the basis of measurements and statistics (method A. The authors proposed their own research methodology, taking into account measurement capabilities of the applied system and the specific character of the robot work. Calculations employed universal computing systems based on standard algorithms. The results obtained from the research and calculations precisely defined key uncertainties allowing for objective evaluation of industrial robot errors identified by the Renishaw XL80 system.

  13. Testing the Feasibility of a Low-Cost Network Performance Measurement Infrastructure

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, Scott [Indiana Univ., Bloomington, IN (United States). International Networks; Schopf, Jennifer M. [Indiana Univ., Bloomington, IN (United States). International Networks; Miller, Kenneth [Pennsylvania State Univ., University Park, PA (United States). Telecommunications and Networking Services; Zurawski, Jason [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Sciences Network

    2016-07-01

    Todays science collaborations depend on reliable, high performance networks, but monitoring the end-to-end performance of a network can be costly and difficult. The most accurate approaches involve using measurement equipment in many locations, which can be both expensive and difficult to manage due to immobile or complicated assets. The perfSONAR framework facilitates network measurement making management of the tests more reasonable. Traditional deployments have used over-provisioned servers, which can be expensive to deploy and maintain. As scientific network uses proliferate, there is a desire to instrument more facets of a network to better understand trends. This work explores low cost alternatives to assist with network measurement. Benefits include the ability to deploy more resources quickly, and reduced capital and operating expenditures. Finally, we present candidate platforms and a testing scenario that evaluated the relative merits of four types of small form factor equipment to deliver accurate performance measurements.

  14. High-Accuracy Spherical Near-Field Measurements for Satellite Antenna Testing

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2017-01-01

    The spherical near-field antenna measurement technique is unique in combining several distinct advantages and it generally constitutes the most accurate technique for experimental characterization of radiation from antennas. From the outset in 1970, spherical near-field antenna measurements have...... matured into a well-established technique that is widely used for testing antennas for many wireless applications. In particular, for high-accuracy applications, such as remote sensing satellite missions in ESA's Earth Observation Programme with uncertainty requirements at the level of 0.05dB - 0.10d......B, the spherical near-field antenna measurement technique is generally superior. This paper addresses the means to achieving high measurement accuracy; these include the measurement technique per se, its implementation in terms of proper measurement procedures, the use of uncertainty estimates, as well as facility...

  15. Modified SPC for short run test and measurement process in multi-stations

    Science.gov (United States)

    Koh, C. K.; Chin, J. F.; Kamaruddin, S.

    2018-03-01

    Due to short production runs and measurement error inherent in electronic test and measurement (T&M) processes, continuous quality monitoring through real-time statistical process control (SPC) is challenging. Industry practice allows the installation of guard band using measurement uncertainty to reduce the width of acceptance limit, as an indirect way to compensate the measurement errors. This paper presents a new SPC model combining modified guard band and control charts (\\bar{\\text{Z}} chart and W chart) for short runs in T&M process in multi-stations. The proposed model standardizes the observed value with measurement target (T) and rationed measurement uncertainty (U). S-factor (S f) is introduced to the control limits to improve the sensitivity in detecting small shifts. The model was embedded in automated quality control system and verified with a case study in real industry.

  16. Measurement of talent in team handball: the questionable use of motor and physical tests.

    Science.gov (United States)

    Lidor, Ronnie; Falk, Bareket; Arnon, Michal; Cohen, Yoram; Segal, Gil; Lander, Yael

    2005-05-01

    Testing for selection is one of the most important fundamentals in any multistep sport program. In most ball games, coaches assess motor, physical, and technical skills on a regular basis in early stages of talent identification and development. However, selection processes are complex, are often unstructured, and lack clear-cut theory-based knowledge. For example, little is known about the relevance of the testing process to the final selection of the young prospects. The purpose of this study was to identify motor, physical, and skill variables that could provide coaches with relevant information in the selection process of young team handball players. In total, 405 players (12-13 years of age at the beginning of the testing period) were recommended by their coaches to undergo a battery of tests prior to selection to the Junior National Team. This number is the sum of all players participating in the different phases of the program. However, not all of them took part in each testing phase. The battery included physical measurements (height and weight), a 4 x 10-m running test, explosive power tests (medicine ball throw and standing long jump), speed tests (a 20-m sprint from a standing position and a 20-m sprint with a flying start), and a slalom dribbling test. Comparisons between those players eventually selected to the Junior National Team 2-3 years later with those not selected demonstrated that only the skill test served as a good indicator. In all other measurements, a wide overlap could be seen between the results of the selected and nonselected players. It is suggested that future studies investigate the usefulness of tests reflecting more specific physical ability and cognitive characteristics.

  17. WTP Waste Feed Qualification: Hydrogen Generation Rate Measurement Apparatus Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Stone, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Newell, J. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Smith, T. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Pareizs, J. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-06-01

    The generation rate of hydrogen gas in the Hanford tank waste will be measured during the qualification of the staged tank waste for processing in the Hanford Tank Waste Treatment and Immobilization Plant. Based on a review of past practices in measurement of the hydrogen generation, an apparatus to perform this measurement has been designed and tested for use during waste feed qualification. The hydrogen generation rate measurement apparatus (HGRMA) described in this document utilized a 100 milliliter sample in a continuously-purged, continuously-stirred vessel, with measurement of hydrogen concentration in the vent gas. The vessel and lid had a combined 220 milliliters of headspace. The vent gas system included a small condenser to prevent excessive evaporative losses from the sample during the test, as well as a demister and filter to prevent particle migration from the sample to the gas chromatography system. The gas chromatograph was an on line automated instrument with a large-volume sample-injection system to allow measurement of very low hydrogen concentrations. This instrument automatically sampled the vent gas from the hydrogen generation rate measurement apparatus every five minutes and performed data regression in real time. The fabrication of the hydrogen generation rate measurement apparatus was in accordance with twenty three (23) design requirements documented in the conceptual design package, as well as seven (7) required developmental activities documented in the task plan associated with this work scope. The HGRMA was initially tested for proof of concept with physical simulants, and a remote demonstration of the system was performed in the Savannah River National Laboratory Shielded Cells Mockup Facility. Final verification testing was performed using non-radioactive simulants of the Hanford tank waste. Three different simulants were tested to bound the expected rheological properties expected during waste feed qualification testing. These

  18. AUTOMATED MEASURING COMPLEX FOR ACCEPTANCE TESTING OF DC AND UNDULATED-CURRENT TRACTION MOTORS

    Directory of Open Access Journals (Sweden)

    A. Yu. Drubetskyi

    2016-12-01

    Full Text Available Purpose. In the paper it is necessary: 1 to familiarize the reader with the modern classification of measurement and diagnostics, familiarize with problems of automating the measurement of basic parameters during program execution of qualification tests of traction motors; 2 to make recommendations to improve the measurement ac-curacy, reduce labor intensity of work for carrying out measurements, and reduce the requirements for the qualification of the staff; 3 to provide practical implementation of measurement system, built on the basis of the practical recommendations contained in the article. Methodology. The work presents the classification of measurement and diagnostic tools. The author considered a list of equipment that can be used in measurement systems, as well as third-party options for measuring complex and measuring complex using stand management system. Their functional schemes were proposed. The author compared the advantages and disadvantages of these schemes to make recommendations on areas of their optimal use. Findings. Having analyzed the functional scheme of measuring systems, it was found that the use of the control system microcontroller as a measuring complex is expedient if the measurements have largely a test process control function. The use of a third-party measuring complex is more appropriate in cases when it is required: to eliminate dependence on the stand management system, to provide high mobility and reduce the requirements for the qualification of the staff. Originality. The work presents a brief over-view of the measurement means. The author developed the functional schemes of measuring systems using stand management system and third-party measuring complex, proposed the criteria for evaluating their optimal use. Practical value. Based on the proposed functional diagram, the measuring system on National Instruments hard-ware and software basis was set up. The sensors by LEM Company were used as primary

  19. Determination of soil properties from standard penetration test complemented by torque measurement (SPT-T

    Directory of Open Access Journals (Sweden)

    Anna S. P. Peixoto

    2014-09-01

    Full Text Available The major problem on geotechnical work is to ensure that no settlements occur during the life cycle of the construction. This involves proper design of foundations and their bearing capacity. The Brazilian standard for design and execution of foundations, ABNT (2010 NBR 6122 imposes the utilization of field tests when designing building foundations. The Standard Penetration Test, SPT, ABNT (2001 NBR 6484, is still the most common in-situ test for those purposes. Ranzini (1988 suggested supplementing the conventional SPT with the measurement of the torque (SPT-T required to turn the split spoon after driving, in order to provide a ‘static’ component to a ‘dynamic’ test. The adhesion between the soil and the sampler, obtained by the torque measurement, could be used to calculate the lateral skin friction of piles. This paper describes the SPT-T procedure including both a supplementary equipment and practical aspects. Also it presents an accurate torque measurement, a prediction method to calculate the bearing capacity of piles used in building foundations using the SPT-T test and a comparison between the estimated bearing capacities of building foundations with instrumented load tests in order to validate the method.

  20. TESTING BRAND VALUE MEASUREMENT METHODS IN A RANDOM COEFFICIENT MODELING FRAMEWORK

    OpenAIRE

    Szõcs Attila

    2014-01-01

    Our objective is to provide a framework for measuring brand equity, that is, the added value to the product endowed by the brand. Based on a demand and supply model, we propose a structural model that enables testing the structural effect of brand equity (demand side effect) on brand value (supply side effect), using Monte Carlo simulation. Our main research question is which of the three brand value measurement methods (price premium, revenue premium and profit premium) is more suitable from...

  1. Test Operations Procedure (TOP) 02-2-546 Teleoperated Unmanned Ground Vehicle (UGV) Latency Measurements

    Science.gov (United States)

    2017-01-11

    anti - lock brake systems , or self-leveling systems . 2. FACILITIES AND INSTRUMENTATION. 2.1 Facilities. Testing will be conducted at the...This TOP describes procedures for measuring teleoperated system latencies of Unmanned Ground Vehicles (UGVs) for the purpose of analyzing system ...discrete system components or measurements of latency in autonomous systems . 15. SUBJECT TERMS Unmanned Ground Vehicles, Basic Video Latency, End-to

  2. Measurement of longitudinal impedance for a KAON test pipe model with TSD-calibration method

    International Nuclear Information System (INIS)

    Yin, Y.; Oram, C.; Ilinsky, N.; Reinhardt-Nikulin, P.

    1991-05-01

    We report measurements of longitudinal impedances for a KAON factory beam pipe model by means of the TSD-calibration method. The experimental method and the results are discussed. The frequency band is from 48 MHz up to 900 MHz, within which range the method produces measured impedances accurate enough to be useful in indicating whether a test pipe will have a suitably low impedance. (Author) 9 refs., 7 figs

  3. Testing temperature on interfacial shear strength measurements of epoxy resins at different mixing ratios

    DEFF Research Database (Denmark)

    Petersen, Helga Nørgaard; Thomason, James L.; Minty, Ross

    2015-01-01

    The interfacial properties as Interfacial Shear Stress (IFSS) in fibre reinforced polymers are essential for further understanding of the mechanical properties of the composite. In this work a single fibre testing method is used in combination with an epoxy matrix made from Araldite 506 epoxy resin...... and triethylenetetramine (TETA) hardener. The IFSS was measured by a microbond test developed for a Thermal Mechanical Analyzer. The preliminary results indicate that IFSS has an inverse dependency of both testing temperature and the mixing ratio of hardener and epoxy resin. Especially interesting was the decreasing...

  4. Measuring episodic memory across the lifespan: NIH Toolbox Picture Sequence Memory Test.

    Science.gov (United States)

    Dikmen, Sureyya S; Bauer, Patricia J; Weintraub, Sandra; Mungas, Dan; Slotkin, Jerry; Beaumont, Jennifer L; Gershon, Richard; Temkin, Nancy R; Heaton, Robert K

    2014-07-01

    Episodic memory is one of the most important cognitive domains that involves acquiring, storing and recalling new information. In this article, we describe a new measure developed for the NIH Toolbox, called the Picture Sequence Memory Test (PSMT) that is the first to examine episodic memory across the age range from 3 to 85. We describe the development of the measure and present validation data for ages 20 to 85. The PSMT involves presentation of sequences of pictured objects and activities in a fixed order on a computer screen and simultaneously verbally described, that the participant must remember and then reproduce over three learning trials. The results indicate good test-retest reliability and construct validity. Performance is strongly related to well-established "gold standard" measures of episodic memory and, as expected, much less well correlated with those of a measure of vocabulary. It shows clear decline with aging in parallel with a gold standard summary measure and relates to several other demographic factors and to self-reported general health status. The PSMT appears to be a reliable and valid test of episodic memory for adults, a finding similar to those found for the same measure with children.

  5. Partitioning gas tracer tests for measurement of water in municipal solid waste.

    Science.gov (United States)

    Imhoff, Paul T; Jakubowitch, Andrew; Briening, Michele L; Chiu, Pei C

    2003-11-01

    A key component in the operation of almost all bioreactor landfills is the addition of water to maintain optimal moisture conditions. To determine how much water is needed and where to add it, in situ methods are required to measure water within solid waste. Existing technologies often result in measurements of unknown accuracy, because of the variability of solid waste materials and time-dependent changes in packing density, both of which influence most measurement methods. To overcome these problems, a new technology recently developed by hydrologists for measuring water in the vadose zone--the partitioning gas tracer test--was tested. In this technology, the transport behavior of two gas tracers within solid waste is used to measure the fraction of the void space filled with water. One tracer is conservative and does not react with solids or liquids, while a second tracer partitions into the water and is separated from the conservative tracer during transport. This technology was tested in four different solid waste packings and was capable of determining the volumetric water content to within 48% of actual values, with most measurement errors less than 15%. This technology and the factors that affect its applicability to landfills are discussed in this paper.

  6. [Measuring contrast sensitivity using visual acuity tests in retinal and optic nerve diseases].

    Science.gov (United States)

    Sommer, E; Marré, E; Mierdel, P

    1990-01-01

    The luminance contrast needed to discern various test types was measured with monochromatic and achromatic light to detect discrete functional deficiencies of the retina and optic nerve in cases of normal visual acuity. Landolt rings corresponding to visual acuity levels from 0.04 to 1.0 were used as test types. A significant increase in the necessary minimum contrast was detectable with blue test light on large Landolt rings in patients with diabetic retinopathy, ocular hypertension and glaucoma and with green or yellow test light on medium-sized and small Landolt rings in patients with central serous chorioidopathy and optic atrophy. The additional contrast needed to reach the maximum visual acuity amounts to 14-100% compared with normal visual acuity, depending on the color of the test light and the diagnosis. The amount of contrast needed is greatest in retinal diseases, and it is therefore possible to a certain extent to distinguish these from diseases of the optic nerve.

  7. Design and performance of a microwave strain measuring system for materials tests

    International Nuclear Information System (INIS)

    Billeter, T.R.; Blackburn, L.D.

    1975-12-01

    Excellent sensitivity and accuracy in the measurement of deformation occurring in materials tests have been achieved with a newly developed microwave frequency sensor and instrumentation system with possible application for strain tests inside nuclear reactors. The strain sensor comprises a microwave cavity resonating in the circular TE 113 and TM 110 modes. Detection of axial strain occurs due to the changes of resonant frequency incurred by cavity length changes. Axial strain sensitivity for the TE 113 mode was 6 x 10 -6 per MHz, whereas radial dimensions of the cavity were related to frequency of the TM 110 mode. Aperture coupling of the cavity to the end wall of K/sub a/ band waveguide provided signal excitation of the two monitored modes. Phase locked frequency stability enabled digital count/display of resonant frequencies to within 70 kHz at 35 GHz. Room temperature tension test results demonstrate a strain measuring sensitivity (+- 1 x 10 -6 ) and accuracy (+ -1 percent of the measured value) equivalent to those of electrical resistance strain gages. The system yields accurate measurements of elastic strains as well as small departures from elastic response and hysteresis behavior during unloading and reloading. Creep test results confirm that measurement sensitivity and accuracy are retained in elevated temperature tests. Strain response on loading, subsequent creep deformation and creep recovery after unloading can all be measured in detail. Stability of microwave sensor calibration after exposure for 22 x 10 6 seconds at temperatures from 728 0 K to 866 0 K is shown to be excellent

  8. Spent fuel test - Climax: technical measurements. Interim report, Fiscal Year 1983

    Energy Technology Data Exchange (ETDEWEB)

    Patrick, W.C.; Butkovich, T.R.; Carlson, R.C.; Durham, W.B.; Ganow, H.C.; Hage, G.L.; Majer, E.L.; Montan, D.N.; Nyholm, R.A.; Rector, N.L.

    1984-02-01

    The Spent Fuel Test - Climax (SFT-C) is located 420 m below surface in the Climax stock granite on the Nevada Test Site. The test is being conducted as part of the Nevada Nuclear Waste Storage Investigations. Eleven canisters of spent nuclear reactor fuel were emplaced, and six electrical simulators were energized April-May 1980. The spent-fuel canisters were retrieved and the thermal sources were de-energized in March-April 1983 when test data indicated that test objectives were met during the 3-year storage phase. The SFT-C operational objective of demonstrating the feasibility of packaging, transporting, storing, and retrieving highly radioactive fuel assemblies in a safe and reliable manner has been met. In addition to emplacement and retrieval operations, three exchanges of spent-fuel between the SFT-C and a surface storage facility, conducted during the storage phase, furthered this demonstration. Technical objectives of the test led to development of a technical measurements program, which is the subject of this and three previous interim reports. Geotechnical, seismological, and test status data have been recorded on a continuing basis for the 3-1/2 year duration of the test on more than 900 channels. Data acquisition from the test is now limited to instrumentation calibration and evaluation activities. Data now available for analysis are presented here. Highlights of activities this year include a campaign of in situ stress measurements, mineralogical and petrological studies of pretest core samples, microfracture analyses of laboratory irradiated cores, improved calculations of near-field heat transfer and thermomechanical response during the final months of heating as well as during a six-month cool-down period, metallurgical analyses of selected test components, and further development of the data acquisition and data management systems. 27 references, 68 figures, 10 tables.

  9. Coupon Test of an Elbow Component by Using Vision-based Measurement System

    International Nuclear Information System (INIS)

    Kim, Sung Wan; Jeon, Bub Gyu; Choi, Hyoung Suk; Kim, Nam Sik

    2016-01-01

    Among the various methods to overcome this shortcoming, vision-based methods to measure the strain of a structure are being proposed and many studies are being conducted on them. The vision-based measurement method is a noncontact method for measuring displacement and strain of objects by comparing between images before and after deformation. This method offers such advantages as no limitations in the surface condition, temperature, and shape of objects, the possibility of full filed measurement, and the possibility of measuring the distribution of stress or defects of structures based on the measurement results of displacement and strain in a map. The strains were measured with various methods using images in coupon test and the measurements were compared. In the future, the validity of the algorithm will be compared using stain gauge and clip gage, and based on the results, the physical properties of materials will be measured using a vision-based measurement system. This will contribute to the evaluation of reliability and effectiveness which are required for investigating local damages

  10. Design and testing of an innovative measurement device for tyre-road contact forces

    Science.gov (United States)

    Cheli, F.; Braghin, F.; Brusarosco, M.; Mancosu, F.; Sabbioni, E.

    2011-08-01

    The measurement of tyre-road contact forces is the first step towards the development of new control systems for improving vehicle safety and performances. Tyre-road contact forces measurement systems are very expensive and significantly modify the unsprung masses of the vehicle as well as the rotational inertia of the tyres. Thus, vehicle dynamics results are significantly affected. As a consequence, the measured contact forces do not correspond to the contact forces under real working conditions. A new low-cost tyre-road contact forces measurement system is proposed in this paper that can be applied to passenger cars. Its working principle is based on the measurement of three deformations of the wheel rim through strain gauges. The tyre-rim assembly is thus turned into a sensor for tyre-road contact forces. The influence of the strain gauges position onto the measurement results has been assessed through finite element simulations and experimental tests. It has been proven that, for a large variety of rims, the strain gauge position that leads to high signal-to-noise ratios is almost the same. A dynamic calibration procedure has been developed in order to allow the reconstruction of contact force and torque components once per wheel turn. The capability of the developed device to correctly estimate tyre-road contact forces has been assessed, in a first stage, through indoor laboratory experimental test on an MTS Flat-Trac ® testing machine. Results show that the implemented measuring system allows to reconstruct contact forces once per wheel turn with a precision that is comparable to that of existing high-cost measurement systems. Subsequently, outdoor tests with a vehicle having all four wheels equipped with the developed measuring device have also been performed. Reliability of the measurements provided by the developed sensor has been assessed by comparing the global measured longitudinal/lateral forces and the product of the measured longitudinal

  11. Development and testing of a measure designed to assess the quality of care transitions

    Directory of Open Access Journals (Sweden)

    Eric A. Coleman

    2002-06-01

    Full Text Available Background: To improve the quality of care delivered to older persons receiving care across multiple settings, interventions are needed. However, the absence of a patient-centred measure specifically designed to assess this care has constrained innovation. Objective: To develop a rigorously designed and tested measure, the Care Transition Measure (CTM. Setting: A large, integrated managed care organisation in Colorado with approximately 55,000 members over the age of 65 years. Participants: Patients 65 years and older who were recently discharged from hospital and received subsequent skilled nursing care in a facility or in the home. Methods: Six focus groups of older persons and their caregivers (n=49 were established. Standard qualitative analytic techniques were applied to written transcripts and four key domains were identified: (1 information transfer; (2 patient and caregiver preparation; (3 self-management support; and (4 empowerment to assert preferences. Specific CTM items were developed, pilot tested, and refined. Psychometric testing, conducted in a different population but selected using the same entry criteria (n=60, included content and construct validity, intra-item variation, and floor/ceiling properties. Results: Older patients and clinicians found the measure to be highly relevant and comprehensive (i.e. content validity. Construct validity was assessed by comparing items from the CTM to selected items from a measure developed by Hendriks and colleagues (Medical Care 2001; 39(3: 270–283. Inter-item Spearman correlations ranged 0.388–0.594. No significant floor or ceiling effects were detected. Conclusions: The CTM was developed with substantial input from older patients and their caregivers. Psychometric testing suggested that the measure was valid. The CTM may serve to fill an important gap in health system performance evaluation by measuring the quality of care delivered across settings.

  12. Measuring walking speed in COPD: test-retest reliability of the 30-metre walk test and comparison with the 6-minute walk test.

    Science.gov (United States)

    Andersson, Mikael; Moberg, Linda; Svantesson, Ulla; Sundbom, Ann; Johansson, Henrik; Emtner, Margareta

    2011-12-01

    To examine test-retest reliability of the 30-metre walk test (30mWT) in patients with chronic obstructive pulmonary disease (COPD) and to compare the 30mWT with the 6-minute walk test (6MWT). Forty-nine subjects with stable COPD were included. The 30mWT consists of walking at different walking intensities over a distance of 30 metres - self-selected speed (ss-30mWT) and maximal speed (ms-30mWT). The test was conducted twice and the time to walk 30 metres was recorded. The 6MWT was performed in duplicate on the same day. Test-retest reliability was high: intraclass correlation coefficient (ICC(2.1)) = 0.93 (95% CI 0.87 to 0.97) for maximal walking speed and 0.87 (95% CI 0.78 to 0.93) for self-selected walking speed. Both maximal and self-selected speed had a standard error of measurement (SEM) of 0.07 m/s and SEM% was 4.4 for maximal speed and 5.9 for self-selected speed. The correlation, criterion validity, between ms-30mWT and the 6MWT was r=0.78 (pwalking ability) in patients with COPD. It may be well suited for primary care settings.

  13. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  14. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  15. Mechanical Q-factor measurements on a test mass with a structured surface

    Energy Technology Data Exchange (ETDEWEB)

    Nawrodt, R [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Zimmer, A [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Koettig, T [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Clausnitzer, T [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Bunkowski, A [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Kley, E B [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Schnabel, R [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Danzmann, K [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Nietzsche, S [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Vodel, W [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Tuennermann, A [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Seidel, P [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany)

    2007-07-15

    We present mechanical Q-factors (quality factors) of a crystalline quartz test mass with a nano-structured surface, measured in the temperature regime from 5 to 300 K. The nano-structure was a grating with a period of 2 {mu}m and a depth of about 0.1 {mu}m. Comparative measurements were performed on the plain substrate and on the structured test mass with different numbers of SiO{sub 2}/Ta{sub 2}O{sub 5} coating layers. The measurements at different stages of the test mass fabrication process show that the surface distortion induced by the nanostructure does not severely lower the mechanical Q-factor of the substrate. Damping due to a multi-layer coating stack was found to be orders of magnitude higher. The results provide vital information concerning the potential usage of low-thermal noise nano-structured test masses in future generations of high-precision laser interferometers and in current attempts to measure quantum effects of macroscopic mirror oscillators.

  16. Building out a Measurement Model to Incorporate Complexities of Testing in the Language Domain

    Science.gov (United States)

    Wilson, Mark; Moore, Stephen

    2011-01-01

    This paper provides a summary of a novel and integrated way to think about the item response models (most often used in measurement applications in social science areas such as psychology, education, and especially testing of various kinds) from the viewpoint of the statistical theory of generalized linear and nonlinear mixed models. In addition,…

  17. Examining Method Effect of Synonym and Antonym Test in Verbal Abilities Measure

    Directory of Open Access Journals (Sweden)

    Wahyu Widhiarso

    2015-08-01

    Full Text Available Many researchers have assumed that different methods could be substituted to measure the same attributes in assessment. Various models have been developed to accommodate the amount of variance attributable to the methods but these models application in empirical research is rare. The present study applied one of those models to examine whether method effects were presents in synonym and antonym tests. Study participants were 3,469 applicants to graduate school. The instrument used was the Graduate Academic Potential Test (PAPS, which includes synonym and antonym questions to measure verbal abilities. Our analysis showed that measurement models that using correlated trait–correlated methods minus one, CT-C(M–1, that separated trait and method effect into distinct latent constructs yielded slightly better values for multiple goodness-of-fit indices than one factor model. However, either for the synonym or antonym items, the proportion of variance accounted for by the method is smaller than trait variance. The correlation between factor scores of both methods is high (r = 0.994. These findings confirm that synonym and antonym tests represent the same attribute so that both tests cannot be treated as two unique methods for measuring verbal ability.

  18. Examining Method Effect of Synonym and Antonym Test in Verbal Abilities Measure.

    Science.gov (United States)

    Widhiarso, Wahyu; Haryanta

    2015-08-01

    Many researchers have assumed that different methods could be substituted to measure the same attributes in assessment. Various models have been developed to accommodate the amount of variance attributable to the methods but these models application in empirical research is rare. The present study applied one of those models to examine whether method effects were presents in synonym and antonym tests. Study participants were 3,469 applicants to graduate school. The instrument used was the Graduate Academic Potential Test (PAPS), which includes synonym and antonym questions to measure verbal abilities. Our analysis showed that measurement models that using correlated trait-correlated methods minus one, CT-C(M-1), that separated trait and method effect into distinct latent constructs yielded slightly better values for multiple goodness-of-fit indices than one factor model. However, either for the synonym or antonym items, the proportion of variance accounted for by the method is smaller than trait variance. The correlation between factor scores of both methods is high (r = 0.994). These findings confirm that synonym and antonym tests represent the same attribute so that both tests cannot be treated as two unique methods for measuring verbal ability.

  19. Time, tire measurements forces and moments: a new standard for steady state cornering tyre testing

    NARCIS (Netherlands)

    Oosten, J.J.M. van; Savi, C.; Augustin, M.; Bouhet, O.; Sommer, J.; Colinot, J.P.

    1999-01-01

    In order to develop vehicles which have maximum active safety, car manufacturers need information about the so-called force and moment properties of tyres. Vehicle manufacturers, tyre suppliers and automotive research organisations have advanced test equipment to measure the forces between a tyre

  20. Test-Retest Reliability of Two Patient-Report Measures for Use in Adults with ADHD

    Science.gov (United States)

    Matza, Louis S.; Van Brunt, David L.; Cates, Charlotte; Murray, Lindsey T.

    2011-01-01

    Aims: Childhood attention-deficit/hyperactivity disorder (ADHD) frequently persists into adulthood and continues to impair health-related quality of life (HRQL). Thus, it is important to have validated symptom and HRQL measures for assessing treatment outcomes in this population. The purpose of the current analysis was to assess test-retest…

  1. How Memory Is Tested Influences What Is Measured: Reply to Wyble and Chen (2017)

    Science.gov (United States)

    Swallow, Khena M.; Jiang, Yuhong V.; Tan, Deborah H.

    2017-01-01

    In this response to Wyble and Chen's (2017) commentary on attribute amnesia, we hope to achieve several goals. First, we clarify how our view diverges from that described by Wyble and Chen. We argue that because the surprise memory test is disruptive, it is an insensitive tool for measuring the persistence of recently attended target attributes in…

  2. Noise measurement flight test Boeing Vertol 234/CH47-D helicopter : data and analyses

    Science.gov (United States)

    1984-09-30

    This report is the seventh in a series of seven documenting the FAA helicopter noise measurement program conducted at Dulles International Airport during the summer of 1983. The BV234/CH-47D test program involved the acquisition of detailed acoustica...

  3. A new soil test for quantitative measurement of available and adsorbed boron

    Science.gov (United States)

    Boron soil tests currently in use, do not extract all plant available B but are used by relating the extractable amount of B to plant B content. There is a need to accurately measure all plant available or adsorbed B because B can be toxic to plants at elevated concentrations and can cause marked y...

  4. Good agreement between minimal erythema dose test reactions and objective measurements

    DEFF Research Database (Denmark)

    Bodekær, Mette; Philipsen, Peter Alshede; Karlsmark, Tonny

    2013-01-01

    The erythema resulting from the minimal erythema dose (MED) test is subjectively assessed. The evaluator visually grades erythema on an ordinal scale. Both intra- and interobserver variation have been found for this erythema assessment. We wanted to examine if objective measurements could be used...

  5. Measuring Japanese EFL Student Perceptions of Internet-Based Tests with the Technology Acceptance Model

    Science.gov (United States)

    Dizon, Gilbert

    2016-01-01

    The Internet has made it possible for teachers to administer online assessments with affordability and ease. However, little is known about Japanese English as a Foreign Language (EFL) students' attitudes of internet-based tests (IBTs). Therefore, this study aimed to measure the perceptions of IBTs among Japanese English language learners with the…

  6. Does the Name-Race Implicit Association Test measure racial prejudice?

    NARCIS (Netherlands)

    van Ravenzwaaij, D.; van der Maas, H.L.J.; Wagenmakers, E.-J.

    2011-01-01

    Research using the Implicit Association Test (IAT) has shown that names labeled as Caucasian elicit more positive associations than names labeled as non-Caucasian. One interpretation of this result is that the IAT measures latent racial prejudice. An alternative explanation is that the result is due

  7. Clean test of the electroweak theory by measuring weak boson masses

    International Nuclear Information System (INIS)

    Hioki, Zenro

    1985-01-01

    Role of the weak boson masses in the studies of electroweak higher order effects is surveyed. It is shown that precise measurements of these masses give us quite useful information for performing a clean test of the electroweak theory, and for a heavy fermion search. Effects of supersymmetric particles in these studies are also discussed. (author)

  8. Evaluation of Two Methods for Modeling Measurement Errors When Testing Interaction Effects with Observed Composite Scores

    Science.gov (United States)

    Hsiao, Yu-Yu; Kwok, Oi-Man; Lai, Mark H. C.

    2018-01-01

    Path models with observed composites based on multiple items (e.g., mean or sum score of the items) are commonly used to test interaction effects. Under this practice, researchers generally assume that the observed composites are measured without errors. In this study, we reviewed and evaluated two alternative methods within the structural…

  9. Nijmegen Continuity Questionnaire: Development and testing of a questionnaire that measures continuity of care

    NARCIS (Netherlands)

    Uijen, A.A.; Schellevis, F.G.; Bosch, W.J. van den; Mokkink, H.G.A.; Weel, C. van; Schers, H.J.

    2011-01-01

    OBJECTIVE: To develop and pilot test a generic questionnaire to measure continuity of care from the patient's perspective across primary and secondary care settings. STUDY DESIGN AND SETTING: We developed the Nijmegen Continuity Questionnaire (NCQ) based on a systematic literature review and

  10. Nijmegen Continuity Questionnaire: development and testing of a questionnaire that measures continuity of care.

    NARCIS (Netherlands)

    Uijen, A.A.; Schellevis, F.G.; Bosch, W.J.H.M. van den; Mokkink, H.G.A.; Weel, C. van; Schers, H.J.

    2011-01-01

    Abstract: To develop and pilot test a generic questionnaire to measure continuity of care from the patient's perspective across primary and secondary care settings. We developed the Nijmegen Continuity Questionnaire (NCQ) based on a systematic literature review and analysis of 30 patient interviews.

  11. Test-Retest Reliability of Self-Reported Sexual Health Measures among US Hispanic Adolescents

    Science.gov (United States)

    Jerman, Petra; Berglas, Nancy F.; Rohrbach, Louise A.; Constantine, Norman A.

    2016-01-01

    Objective: Although Hispanic adolescents in the USA are often the focus of sexual health interventions, their response to survey measures has rarely been assessed within evaluation studies. This study documents the test-retest reliability of a wide range of self-reported sexual health values, attitudes, knowledge and behaviours among Hispanic…

  12. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  13. A single well pumping and recovery test to measure in situ acrotelm transmissivity in raised bogs

    NARCIS (Netherlands)

    Schaaf, van der S.

    2004-01-01

    A quasi-steady-state single pit pumping and recovery test to measure in situ the transmissivity of the highly permeable upper layer of raised bogs, the acrotelm, is described and discussed. The basic concept is the expanding depression cone during both pumping and recovery. It is shown that applying

  14. 40 CFR Table C-2 to Subpart C of... - Sequence of Test Measurements

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Sequence of Test Measurements C Table C-2 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Medium. 2 High High. 3 Medium Low. 4 High High. 5 Low Medium. 6 Medium Low. 7 Low Medium. 8 Medium Low. 9...

  15. The Major Field Test in Business: A Direct Measure of Learning in Common Business Disciplines

    Science.gov (United States)

    Simmons, Susan A.; Jones, Wesley M., Jr; Bolt, Cynthia E.

    2015-01-01

    Assurance of learning and its assessment are critical focal points in collegiate schools of business as programs strive to achieve or maintain Association to Advance Collegiate Schools of Business accreditation. Prior research suggests that student learning in business core disciplines can be measured by the Educational Testing Service Major Field…

  16. In Situ Measurements of the NO2/NO Ratio for Testing Atmospheric Photochemical Models

    Science.gov (United States)

    Jaegle, L.; Webster, C. R.; May, R. D.; Fahey, D. W.; Woodbridge, E. L.; Keim, E. R.; Gao, R. S.; Proffitt, M. H.; Stimpfle, R. M.; Salawitch, R. J.

    1994-01-01

    Simultaneous in situ measurements of NO2, NO, O3, ClO, pressure and temperature have been made for the first time, presenting a unique opportunity to test our current understanding of the photochemistry of the lower stratosphere. Data were collected from several flights of the ER-2 aircraft at mid-latitudes in May 1993 during NASA's Stratospheric Photochemistry, Aerosols and Dynamics Expedition (SPADE). The daytime ratio of NO2/NO remains fairly constant at 19 km with a typical value of 0.68 and standard deviation of +/- 0.17. The ratio observations are compared with simple steady-state calculations based on laboratory-measured reaction rates and modeled NO2 photolysis rates. At each measurement point the daytime NO2/NO with its measurement uncertainty overlap the results of steady-state calculations and associated uncertainty. However, over all the ER-2 flights examined, the model systematically overestimates the ratio by 40% on average. Possible sources of error are examined in both model and measurements. It is shown that more accurate laboratory determinations of the NO + O3 reaction rate and of the NO2 cross-sections in the 200-220 K temperature range characteristic of the lower stratosphere would allow for a more robust test of our knowledge of NO(x) photochemistry by reducing significant sources of uncertainties in the interpretation of stratospheric measurements. The present measurements are compared with earlier observations of the ratio at higher altitudes.

  17. Development of an implicit overall well-being measure using the Implicit Association Test.

    Science.gov (United States)

    Díaz, Darío; Horcajo, Javier; Blanco, Amalio

    2009-11-01

    Usually, well-being has been measured by means of questionnaires or scales. Although most of these methods have a high level of reliability and validity, they present some limitations. In order to try to improve well-being assessment, in the present work, the authors propose a new complementary instrument: The Implicit Overall Well-Being Measure (IOWBM). The Implicit Association Test (IAT) was adapted to measure wellbeing by assessing associations of the self with well-being-related words. In the first study, the IOWBM showed good internal consistency and adequate temporal reliability. In the second study, it presented weak correlations with explicit well-being measures. The third study examined the validity of the measure, analyzing the effect of traumatic memories on implicit well-being. The results showed that people who remember a traumatic event presented low levels of implicit well-being compared with people in the control condition.

  18. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  19. The Latent Class Model as a Measurement Model for Situational Judgment Tests

    Directory of Open Access Journals (Sweden)

    Frank Rijmen

    2011-11-01

    Full Text Available In a situational judgment test, it is often debatable what constitutes a correct answer to a situation. There is currently a multitude of scoring procedures. Establishing a measurement model can guide the selection of a scoring rule. It is argued that the latent class model is a good candidate for a measurement model. Two latent class models are applied to the Managing Emotions subtest of the Mayer, Salovey, Caruso Emotional Intelligence Test: a plain-vanilla latent class model, and a second-order latent class model that takes into account the clustering of several possible reactions within each hypothetical scenario of the situational judgment test. The results for both models indicated that there were three subgroups characterised by the degree to which differentiation occurred between possible reactions in terms of perceived effectiveness. Furthermore, the results for the second-order model indicated a moderate cluster effect.

  20. Strain measurement technique for elevated temperature tensile and creep testing of foil-gage metals

    Science.gov (United States)

    Blackburn, L. B.

    1988-01-01

    This paper describes a strain measurement technique suitable for elevated-temperature tensile and creep testing of foil-gage metals, using a modified commonly available mechanical extensometer in conjunction with a displacement transducer. The extensometer was modified by attaching to it a counterbalance (to reduce the effect of the extensometer weight on the total maximum test load) and by incorporating a conical tip/flat-edge design (to minimize induced stresses in the specimen resulting from extensometer attachment). Creep tests were performed on 0.102-mm-thick specimens of Ti-6Al-4V at temperatures of 427 and 538 C, at nominal applied stresses of 310.3 and 172.4 MPa, respectively. Examination of the resulting creep curves suggested that the strain measurement system provided actual creep strain values with good accuracy.

  1. Want Amid Plenty: Developing and Testing a Cross-National Measure of Anomie

    Directory of Open Access Journals (Sweden)

    John K. Cochran

    2008-11-01

    Full Text Available One of the biggest challenges facing researchers trying to empirically test structural or institutional anomie theories is the operationalization of the key concept of anomie. This challenge is heightened by the data constraints involved in cross-national research. As a result, researchers have been forced to rely on surrogate or proxy measures of anomie and indirect tests of the theories. The purpose of this study is to examine an innovative and more theoretically sound measure of anomie and to test its ability to make cross-national predictions of serious crime. Our results are supportive of the efficacy of this construct to explain cross-national variations in crime rates. Nations with the highest rates of structural anomie also have the highest predicted rates of homicide.

  2. Standard practices for verification of displacement measuring systems and devices used in material testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These practices cover procedures and requirements for the calibration and verification of displacement measuring systems by means of standard calibration devices for static and quasi-static testing machines. This practice is not intended to be complete purchase specifications for testing machines or displacement measuring systems. Displacement measuring systems are not intended to be used for the determination of strain. See Practice E83. 1.2 These procedures apply to the verification of the displacement measuring systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the displacement-measuring system(s) to be verified. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems m...

  3. Sentence Repetition Test for Measurement of Grammatical Development in Farsi Speaking Children

    Directory of Open Access Journals (Sweden)

    Mohammad Kamali

    2011-06-01

    Full Text Available Background and Aim: valid identification, prevention, and treatment of language disorders are a high priority for the speech and language professionals. One method for studying language development is sentence repetition that is faster to implement and analysis than other procedures. The aim of this project was constructing sentence repetition test as a quick measure of grammatical potency in 2.5 to 4 year old children.Methods: Sentences appropriate for 2.5 to 4 year old children were selected during several stages by speech and language pathologist and linguists. The validity of sentences was assessed by professional masters in this theme. Subsequently, 41 sentences including those with 80% high validity were selected as the test sentences. Appropriate pictures were also provided with sentences. The test was administrated to 72 children in 3 groups (2.5-3, 3-3.5, and 3.5-4 year olds, gender matched. The reliability was administered with a test-retest design across a 2 weeks interval.Results: Content validity Index for this test was 80%. "Test-retest reliability” was used for reliability of this test. The Interclass correlation coefficient for this test was 0.95 and standard error measurement was 7.45. The average of scores for sentence repetition, between groups was significant (p<0.001, p<0.001, p= 0.014.Conclusion: This sentence repetition test has the appropriate validity and reliability as well as the capability of proper and quick assessment (screening of grammatical development in 2.5 to 4 year old Persian speaking children.

  4. Health care quality measures for children and adolescents in Foster Care: feasibility testing in electronic records.

    Science.gov (United States)

    Deans, Katherine J; Minneci, Peter C; Nacion, Kristine M; Leonhart, Karen; Cooper, Jennifer N; Scholle, Sarah Hudson; Kelleher, Kelly J

    2018-02-22

    Preventive quality measures for the foster care population are largely untested. The objective of the study is to identify healthcare quality measures for young children and adolescents in foster care and to test whether the data required to calculate these measures can be feasibly extracted and interpreted within an electronic health records or within the Statewide Automated Child Welfare Information System. The AAP Recommendations for Preventive Pediatric Health Care served as the guideline for determining quality measures. Quality measures related to well child visits, developmental screenings, immunizations, trauma-related care, BMI measurements, sexually transmitted infections and depression were defined. Retrospective chart reviews were performed on a cohort of children in foster care from a single large pediatric institution and related county. Data available in the Ohio Statewide Automated Child Welfare Information System was compared to the same population studied in the electronic health record review. Quality measures were calculated as observed (received) to expected (recommended) ratios (O/E ratios) to describe the actual quantity of recommended health care that was received by individual children. Electronic health records and the Statewide Automated Child Welfare Information System data frequently lacked important information on foster care youth essential for calculating the measures. Although electronic health records were rich in encounter specific clinical data, they often lacked custodial information such as the dates of entry into and exit from foster care. In contrast, Statewide Automated Child Welfare Information System included robust data on custodial arrangements, but lacked detailed medical information. Despite these limitations, several quality measures were devised that attempted to accommodate these limitations. In this feasibility testing, neither the electronic health records at a single institution nor the county level Statewide

  5. Carbon dioxide test as an additional clinical measure of treatment response in panic disorder

    Directory of Open Access Journals (Sweden)

    Valença Alexandre M.

    2002-01-01

    Full Text Available OBJECTIVE: We aim to determine if a treatment with a dose of clonazepam - 2 mg/day, for 6 weeks, blocks spontaneous panic attacks and the ones induced by the inhalation of 35% carbon dioxide (CO2 in panic disorder (PD patients. The CO2 challenge-test may be a useful addition tool for measuring the pharmacological response during the initial phase (6 weeks in the treatment of PD. METHOD: Eighteen PD patients drug free for a week participated in a carbon dioxide challenge test. Fourteen had a panic attack and were openly treated for a 6-week period with clonazepam. At the end of the 6-week period they were submitted again to the CO2 challenge test. RESULTS: After 6 weeks of treatment with clonazepam, 12 of 14 PD patients (85.7% did not have a panic attack after the CO2 challenge test. Just 2 of 14 patients (14.3% had a panic attack after the CO2 challenge test. Ten of 14 (71.4% PD patients had panic free status after clonazepam treatment. The 2 patients who had a panic attack in the sixth week, after the CO2 test, did not have panic free status after the treatment with clonazepam. CONCLUSION: The CO2-test may be a valid tool for testing and predicting the drug response.

  6. Spent Fuel Test - Climax: technical measurements. Interim report, fiscal year 1982

    International Nuclear Information System (INIS)

    Patrick, W.C.; Ballou, L.B.; Butkovich, T.R.

    1983-02-01

    The Spent Fuel Test - Climax (SFT-C) is located 420 m below surface in the Climax stock granite on the Nevada Test Site. The test is being conducted for the US Department of Energy (DOE) under the technical direction of the Lawrence Livermore National Laboratory (LLNL). Eleven canisters of spent nuclear reactor fuel were emplaced, and six electrical simulators were energized April to May 1980, thus initiating a test with a planned 3- to 5-year fuel storage phase. The SFT-C operational objective of demonstrating the feasibility of packaging, transporting, storing, and retrieving highly radioactive fuel assemblies in a safe and reliable manner has been met. Three exchanges of spent fuel between the SFT-C and a surface storage facility furthered this demonstration. Technical objectives of the test led to development of a technical measurements program, which is the subject of this and two previous interim reports. Geotechnical, seismological, and test status data have been recorded on a continuing basis for the first 2-1/2 years of the test on more than 900 channels. Data continue to be acquired from the test. Some data are now available for analysis and are presented here. Highlights of activities this year include analysis of fracture data obtained during site characterization, laboratory studies of radiation effects and drilling damage in Climax granite, improved calculations of near-field heat transfer and thermomechanical response, a ventilation effects study, and further development of the data acquisition and management systems

  7. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  8. Full-Scale Passive Earth Entry Vehicle Landing Tests: Methods and Measurements

    Science.gov (United States)

    Littell, Justin D.; Kellas, Sotiris

    2018-01-01

    During the summer of 2016, a series of drop tests were conducted on two passive earth entry vehicle (EEV) test articles at the Utah Test and Training Range (UTTR). The tests were conducted to evaluate the structural integrity of a realistic EEV vehicle under anticipated landing loads. The test vehicles were lifted to an altitude of approximately 400m via a helicopter and released via release hook into a predesignated 61 m landing zone. Onboard accelerometers were capable of measuring vehicle free flight and impact loads. High-speed cameras on the ground tracked the free-falling vehicles and data was used to calculate critical impact parameters during the final seconds of flight. Additional sets of high definition and ultra-high definition cameras were able to supplement the high-speed data by capturing the release and free flight of the test articles. Three tests were successfully completed and showed that the passive vehicle design was able to withstand the impact loads from nominal and off-nominal impacts at landing velocities of approximately 29 m/s. Two out of three test resulted in off-nominal impacts due to a combination of high winds at altitude and the method used to suspend the vehicle from the helicopter. Both the video and acceleration data captured is examined and discussed. Finally, recommendations for improved release and instrumentation methods are presented.

  9. Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

    Directory of Open Access Journals (Sweden)

    T. Schietinger

    2016-10-01

    Full Text Available The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.

  10. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. [Multiple-choice vocabulary intelligence test MWT in schizophrenia: valid measure of premorbid intelligence?].

    Science.gov (United States)

    Wittorf, Andreas; Wiedemann, Georg; Klingberg, Stefan

    2014-03-01

    The multiple-choice vocabulary intelligence test MWT (Mehrfachwahl-Wortschatz-Intelligenztest) as a measure of premorbid IQ is widely used in clinical practice and research in Germany. The study examined whether the MWT is actually insensitive to brain dysfunction and psychopathology in patients with schizophrenia. 81 post-acute patients with schizophrenia and 27 matched healthy controls completed the MWT at two points in time. At baseline, we further applied a neuropsychological test battery and a psychopathology rating. The multiple linear regression analysis showed that the MWT-IQ of patients is significantly confounded by neuropsychological dysfunctions and psychopathology. The repeated measurement ANOVA pointed to a significant recovery effect of the MWT-IQ during clinical remission in the patient group. The results question the validity of the MWT as a measure of premorbid IQ in schizophrenia. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Measurement of PCB emissions from building surfaces using a novel portable emission test cell

    DEFF Research Database (Denmark)

    Lyng, Nadja; Gunnarsen, Lars Bo; Andersen, Helle Vibeke

    2016-01-01

    Polychlorinated biphenyls (PCBs) were used in building materials like caulks and paints from 1930 e1970s and in some cases that caused elevated PCB concentrations in the indoor air at levels considered harmful to occupant health. PCBs are semivolatile organic compounds and capable of spreading from...... and there is a need to prioritise remediation measures on different materials. An inexpensive and portable emission test cell was developed to resemble indoor conditions in relation to the area specific ventilation rate. Emissions were measured using the test cell in the laboratory on freshly made PCB paint. Further......, the chamber was used for determining emissions from PCB-containing building materials in the field as well as remediated walls. The measurements showed that sorption of PCBs to chamber walls was insignificant after 2-4 days of exposure to the source. Over a period of two weeks emission rates did not change...

  13. Measurement of LNAPL flux using single-well intermittent mixing tracer dilution tests.

    Science.gov (United States)

    Smith, Tim; Sale, Tom; Lyverse, Mark

    2012-01-01

    The stability of subsurface Light Nonaqueous Phase Liquids (LNAPLs) is a key factor driving expectations for remedial measures at LNAPL sites. The conventional approach to resolving LNAPL stability has been to apply Darcy's Equation. This paper explores an alternative approach wherein single-well tracer dilution tests with intermittent mixing are used to resolve LNAPL stability. As a first step, an implicit solution for single-well intermittent mixing tracer dilution tests is derived. This includes key assumptions and limits on the allowable time between intermittent mixing events. Second, single-well tracer dilution tests with intermittent mixing are conducted under conditions of known LNAPL flux. This includes a laboratory sand tank study and two field tests at active LNAPL recovery wells. Results from the sand tank studies indicate that LNAPL fluxes in wells can be transformed into formation fluxes using corrections for (1) LNAPL thicknesses in the well and formation and (2) convergence of flow to the well. Using the apparent convergence factor from the sand tank experiment, the average error between the known and measured LNAPL fluxes is 4%. Results from the field studies show nearly identical known and measured LNAPL fluxes at one well. At the second well the measured fluxes appear to exceed the known value by a factor of two. Agreement between the known and measured LNAPL fluxes, within a factor of two, indicates that single-well tracer dilution tests with intermittent mixing can be a viable means of resolving LNAPL stability. © 2012, The Author(s). Ground Water © 2012, National Ground Water Association.

  14. Association with isokinetic ankle strength measurements and normal clinical muscle testing in sciatica patients.

    Science.gov (United States)

    Ustun, N; Erol, O; Ozcakar, L; Ceceli, E; Ciner, O Akar; Yorgancioglu, Z R

    2013-01-01

    Sensitive muscle strength tests are needed to measure muscle strength in the diagnosis and management of sciatica patients. The aim of this study was to assess the isokinetic muscle strength in sciatica patients' and control subjects' ankles that exhibited normal ankle muscle strength when measured clinically. Forty-six patients with L5 and/or S1 nerve compression, and whose age, sex, weight, and height matched 36 healthy volunteers, were recruited to the study. Heel-walking, toe-walking, and manual muscle testing were used to perform ankle dorsiflexion and plantar flexion strengths in clinical examination. Patients with normal ankle dorsiflexion and plantar flexion strengths assessed by manual muscle testing and heel-and toe-walking tests were included in the study. Bilateral isokinetic (concentric/concentric) ankle plantar-flexion-dorsiflexion measurements of the patients and controls were performed within the protocol of 30°/sec (5 repetitions). Peak torque and peak torque/body weight were obtained for each ankle motion of the involved limb at 30°/s speed. L5 and/or S1 nerve compression was evident in 46 patients (76 injured limbs). Mean disease duration was two years. The plantar flexion muscle strength of the patients was found to be lower than that of the controls (p=0.036). The dorsiflexion muscle strength of the patients was found to be the same as that of the controls (p=0.211). Isokinetic testing is superior to clinical muscle testing when evaluating ankle plantar flexion torque in sciatica patients. Therefore, isokinetic muscle testing may be helpful when deciding whether to place a patient into a focused rehabilitation program.

  15. Uncertainty measurement with the kinematic telescopic bar during industrial robot inaccuracy tests

    Directory of Open Access Journals (Sweden)

    Józwik Jerzy

    2017-01-01

    Full Text Available Abstract. The subject of this article is the assessment of measurement uncertainty with the kinematic telescopic bar QC20-W in the accuracy test of MOTOMAN HP20 industrial robot. The measurements were performed to determine the statistical uncertainty of error measurement using the system applied. Analysed in tests was the robot’s ability to recreate a circular outline through standard, complex and extended measurement of uncertainty measurement. The obtained results were served to perform rapid evaluation of robot inaccuracy. These uncertainties were based on the information included in the device calibration certificate (estimated with method B but also on the basis of measurements and statistical data (estimated with method A. These components of the uncertainty budget take relatively small values (uc=0.818÷4.130; U=1.636÷8.260 for k=2, which proves that a properly selected method was applied to the research task. The method of research and calculation precisely identified key uncertainties allowing for an objective assessment of the industrial robot errors carried out with Renishaw the kinematic telescopic bar.

  16. Measuring Episodic Memory Across the Lifespan: NIH Toolbox Picture Sequence Memory Test

    Science.gov (United States)

    Dikmen, Sureyya S.; Bauer, Patricia J.; Weintraub, Sandra; Mungas, Dan; Slotkin, Jerry; Beaumont, Jennifer L.; Gershon, Richard; Temkin, Nancy R.; Heaton, Robert K.

    2014-01-01

    Episodic memory is one of the most important cognitive domains that involves acquiring, storing and recalling new information. In this article, we describe a new measure developed for the NIH Toolbox, called the Picture Sequence Memory Test (PSMT) that is the first to examine episodic memory across the age range from 3 to 85. We describe the development of the measure and present validation data for ages 20 to 85. The PSMT involves presentation of sequences of pictured objects and activities in a fixed order on a computer screen and simultaneously verbally described, that the participant must remember and then reproduce over three learning trials. The results indicate good test–retest reliability and construct validity. Performance is strongly related to well-established “gold standard” measures of episodic memory and, as expected, much less well correlated with those of a measure of vocabulary. It shows clear decline with aging in parallel with a gold standard summary measure and relates to several other demographic factors and to self-reported general health status. The PSMT appears to be a reliable and valid test of episodic memory for adults, a finding similar to those found for the same measure with children. PMID:24960230

  17. Recurrence network measures for hypothesis testing using surrogate data: Application to black hole light curves

    Science.gov (United States)

    Jacob, Rinku; Harikrishnan, K. P.; Misra, R.; Ambika, G.

    2018-01-01

    Recurrence networks and the associated statistical measures have become important tools in the analysis of time series data. In this work, we test how effective the recurrence network measures are in analyzing real world data involving two main types of noise, white noise and colored noise. We use two prominent network measures as discriminating statistic for hypothesis testing using surrogate data for a specific null hypothesis that the data is derived from a linear stochastic process. We show that the characteristic path length is especially efficient as a discriminating measure with the conclusions reasonably accurate even with limited number of data points in the time series. We also highlight an additional advantage of the network approach in identifying the dimensionality of the system underlying the time series through a convergence measure derived from the probability distribution of the local clustering coefficients. As examples of real world data, we use the light curves from a prominent black hole system and show that a combined analysis using three primary network measures can provide vital information regarding the nature of temporal variability of light curves from different spectroscopic classes.

  18. Gas permeability of bentonite barriers: development, construction and testing of a measurement system

    Directory of Open Access Journals (Sweden)

    Heraldo Nunes Pitanga

    Full Text Available Abstract This article proposes a testing device to quickly and reliably estimate the gas permeability of bentonite-based clay barriers used in landfill cover systems. The testing methodology is based on a transient gas flow regime that passes through the barrier, therefore not requiring the use of sophisticated equipment that aim to maintain constant differential pressure and measure the gas flow, common requirements for testing methods under a permanent flow regime. To confirm the feasibility of the proposed technique, tests were performed on a pure hydrated bentonite layer, which subsequently encompassed samples of geosynthetic clay liner (GCL at different moisture contents. Geosynthetic clay liners are often selected as a part of the barrier layer for cover systems in solid waste landfills to prevent infiltration of rainfall and migration of biogas into the atmosphere. The results confirmed the equipment reliability and differentiate the different responses of the gas flow barriers studied, considering their different compositions and different moistures.

  19. Relatives' view on collaboration with nurses in acute wards: development and testing of a new measure

    DEFF Research Database (Denmark)

    Lindhardt, Tove; Nyberg, Per; Hallberg, Ingalill Rahm

    2008-01-01

    BACKGROUND: Collaboration between relatives and nurses in acute care settings is sparsely investigated, and that mostly from nurses' point of view. Feasible and valid instruments are needed for assessing collaboration, its prerequisites and outcome. OBJECTIVES: To develop and test an instrument...... to assess, from the relatives' perspective, collaboration between relatives of frail elderly patients and nurses in acute hospital wards, as well as prerequisites for, and outcome of, collaboration. DESIGN: Instrument development and psychometric testing. SETTING: Acute medical and geriatric wards......, before testing it among 156 relatives. Construct validity was assessed by principal component analysis and test for correlation between factors. Predictive validity was assessed by comparing factor scores with scores in outcome measures. Internal consistency was assessed by Cronbach's alpha for factors...

  20. An Evaluation of Test and Physical Uncertainty of Measuring Vibration in Wooden Junctions

    DEFF Research Database (Denmark)

    Dickow, Kristoffer Ahrens; Kirkegaard, Poul Henning; Andersen, Lars Vabbersgaard

    2012-01-01

    In the present paper a study of test and material uncertainty in modal analysis of certain wooden junctions is presented. The main structure considered here is a T-junction made from a particleboard plate connected to a spruce beam of rectangular cross section. The size of the plate is 1.2 m by 0.......6 m. The T-junctions represent cut-outs of actual full size floor assemblies. The aim of the experiments is to investigate the underlying uncertainties of both the test method as well as variation in material and craftmanship. For this purpose, ten nominally identical junctions are tested and compared...... to each other in terms of modal parameters such as natural frequencies, modeshapes and damping. Considerations regarding the measurement procedure and test setup are discussed. The results indicate a large variation of the response at modes where the coupling of torsion in the beam to bending of the plate...

  1. A Modified Jonckheere Test Statistic for Ordered Alternatives in Repeated Measures Design

    Directory of Open Access Journals (Sweden)

    Hatice Tül Kübra AKDUR

    2016-09-01

    Full Text Available In this article, a new test based on Jonckheere test [1] for  randomized blocks which have dependent observations within block is presented. A weighted sum for each block statistic rather than the unweighted sum proposed by Jonckheereis included. For Jonckheere type statistics, the main assumption is independency of observations within block. In the case of repeated measures design, the assumption of independence is violated. The weighted Jonckheere type statistic for the situation of dependence for different variance-covariance structure and the situation based on ordered alternative hypothesis structure of each block on the design is used. Also, the proposed statistic is compared to the existing test based on Jonckheere in terms of type I error rates by performing Monte Carlo simulation. For the strong correlations, circular bootstrap version of the proposed Jonckheere test provides lower rates of type I error.

  2. A broadband variable-temperature test system for complex permittivity measurements of solid and powder materials

    Science.gov (United States)

    Zhang, Yunpeng; Li, En; Zhang, Jing; Yu, Chengyong; Zheng, Hu; Guo, Gaofeng

    2018-02-01

    A microwave test system to measure the complex permittivity of solid and powder materials as a function of temperature has been developed. The system is based on a TM0n0 multi-mode cylindrical cavity with a slotting structure, which provides purer test modes compared to a traditional cavity. To ensure the safety, effectiveness, and longevity, heating and testing are carried out separately and the sample can move between two functional areas through an Alundum tube. Induction heating and a pneumatic platform are employed to, respectively, shorten the heating and cooling time of the sample. The single trigger function of the vector network analyzer is added to test software to suppress the drift of the resonance peak during testing. Complex permittivity is calculated by the rigorous field theoretical solution considering multilayer media loading. The variation of the cavity equivalent radius caused by the sample insertion holes is discussed in detail, and its influence to the test result is analyzed. The calibration method for the complex permittivity of the Alundum tube and quartz vial (for loading powder sample), which vary with the temperature, is given. The feasibility of the system has been verified by measuring different samples in a wide range of relative permittivity and loss tangent, and variable-temperature test results of fused quartz and SiO2 powder up to 1500 °C are compared with published data. The results indicate that the presented system is reliable and accurate. The stability of the system is verified by repeated and long-term tests, and error analysis is presented to estimate the error incurred due to the uncertainties in different error sources.

  3. Comparison between deformation modulus of rock mass measured by plate jacking and dilatometer tests

    Directory of Open Access Journals (Sweden)

    Mohsen Rezaei

    2017-09-01

    Full Text Available For determination of the in-situ deformation modulus of rock mass at Bakhtiari Dam site, located in south-west of Iran, plate jacking tests (PJT and dilatometer tests (DLT carried out during the geotechnical investigations. In this study, the results of PJTs and DLTs were compared. This comparison involves 89 vertical and horizontal PJTs and 83 DLTs carried out in 6 rock units of Sarvak formation. Although, both PJTs and DLTs in the Bakhtiari Dam site were performed in same geological and geotechnical conditions, but there are not sufficient side by side data to make a paired two samples correlation. Therefore, the mean of in-situ data was compared at each rock unit. Besides Mann–Whitney U tests were performed to compare in-situ test results. The comparison shows that the deformation modulus measured by both methods has no significant differences. However, in low quality rock masses the moduli measured by the use of DLTs were greater than the modulus measured by PJTs. Conversely, in high quality rock masses the results of PJTs were greater than DLT’s.

  4. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30.

  5. Alexithymia. The development of a valid and reliable projective measure (the objectively scored Archetypal9 Test).

    Science.gov (United States)

    Cohen, K; Auld, F; Demers, L; Catchlove, R

    1985-10-01

    The aim of this study was to examine whether the Archetypal9 Test (AT9) could meet the need for a valid and reliable test with which to measure the alexithymic trait cluster. Participants in this study included 61 patients drawn from pain clinics in Montreal (Royal Victoria Hospital) and Detroit (Henry Ford Hospital) and 30 patients undergoing minor surgery at the Royal Victoria Hospital in Montreal. All 91 subjects took both the AT9 Test and the Clarke Vocabulary Scale. The results of the attempts at validation reveal that the objectively scored AT9 Test (SAT9) is a highly internally consistent instrument, that it has demonstrated construct validity, and that it can significantly discriminate between patient groups (pain patients and medical patients). The SAT9 is positively related to age, inversely related to occupational level, and uncorrelated with IQ (as measured by the Clarke Vocabulary Scale). The authors concluded that thus far, the SAT9 has proven to be a valid instrument which can be used to measure a central feature of alexithymia.

  6. Standard Test Method for Measuring Heat Flux Using Surface-Mounted One-Dimensional Flat Gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes the measurement of the net heat flux normal to a surface using flat gages mounted onto the surface. Conduction heat flux is not the focus of this standard. Conduction applications related to insulation materials are covered by Test Method C 518 and Practices C 1041 and C 1046. The sensors covered by this test method all use a measurement of the temperature difference between two parallel planes normal to the surface to determine the heat that is exchanged to or from the surface in keeping with Fourier’s Law. The gages operate by the same principles for heat transfer in either direction. 1.2 This test method is quite broad in its field of application, size and construction. Different sensor types are described in detail in later sections as examples of the general method for measuring heat flux from the temperature gradient normal to a surface (1). Applications include both radiation and convection heat transfer. The gages have broad application from aerospace to biomedical en...

  7. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    International Nuclear Information System (INIS)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30

  8. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  9. UPTF test instrumentation. Measurement system identification, engineering units and computed parameters

    International Nuclear Information System (INIS)

    Sarkar, J.; Liebert, J.; Laeufer, R.

    1992-11-01

    This updated version of the previous report /1/ contains, besides additional instrumentation needed for 2D/3D Programme, the supplementary instrumentation in the inlet plenum of SG simulator and hot and cold leg of broken loop, the cold leg of intact loops and the upper plenum to meet the requirements (Test Phase A) of the UPTF Programme, TRAM, sponsored by the Federal Minister of Research and Technology (BMFT) of the Federal Republic of Germany. For understanding, the derivation and the description of the identification codes for the entire conventional and advanced measurement systems classifying the function, and the equipment unit, key, as adopted in the conventional power plants, have been included. Amendments have also been made to the appendices. In particular, the list of measurement systems covering the measurement identification code, instrument, measured quantity, measuring range, band width, uncertainty and sensor location has been updated and extended to include the supplementary instrumentation. Beyond these amendments, the uncertainties of measurements have been precisely specified. The measurement identification codes which also stand for the identification of the corresponding measured quantities in engineering units and the identification codes derived therefrom for the computed parameters have been adequately detailed. (orig.)

  10. Comparison of Test Your Memory and Montreal Cognitive Assessment Measures in Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    Emily J. Henderson

    2016-01-01

    Full Text Available Background. MoCA is widely used in Parkinson’s disease (PD to assess cognition. The Test Your Memory (TYM test is a cognitive screening tool that is self-administered. Objectives. We sought to determine (a the optimal value of TYM to discriminate between PD patients with and without cognitive deficits on MoCA testing, (b equivalent MoCA and TYM scores, and (c interrater reliability in TYM testing. Methods. We assessed the discriminant ability of TYM and the equivalence between TYM and MoCA scores and measured the interrater reliability between three raters. Results. Of the 135 subjects that completed both tests, 55% had cognitive impairment according to MoCA. A MoCA score of 25 was equivalent to a TYM score of 43-44. The area under the receiver operator characteristic (ROC curve for TYM to differentiate between PD-normal and PD-cognitive impairment was 0.82 (95% CI 0.75 to 0.89. The optimal cutoff to distinguish PD-cognitive impairment from PD-normal was ≤45 (sensitivity 90.5%, specificity 59% thereby correctly classifying 76.3% of patients with PD-cognitive impairment. Interrater agreement was high (0.97 and TYM was completed in under 7 minutes (interquartile range 5.33 to 8.52 minutes. Conclusions. The TYM test is a useful and less resource intensive screening test for cognitive deficits in PD.

  11. Spent fuel test - Climax: technical measurements. Interim report, fiscal year 1981

    Energy Technology Data Exchange (ETDEWEB)

    Patrick, W.C.; Ballou, L.B.; Butkovich, T.R.

    1982-04-30

    The Spent Fuel Test-Climax (SFT-C) is located 420 m below surface in the Climax granite stock on the Nevada Test Site. Eleven canisters of spent nuclear reactor fuel were emplaced, and six electrical simulators were energized from April to May 1980, initiating the 3- to 5-year-duration test. The SFT-C operational objective of demonstrating the feasibility of packaging, transporting, storing, and retrieving highly radioactive fuel assemblies in a safe and reliable manner has been met. Technical objectives of the test led to development of a technical measurements program, which is the subject of this report. Geotechnical, seismological, and test status data have been recorded on a continuing basis for the first 1-1/2 years of the test on more than 900 channels. Much of the acquired data are now available for analysis and are presented here. Highlights of activities this year include completion of site characterization field work, major modifications to the data acquisition and the management systems, and the addition of instrument evaluation as an explicit objective of the test.

  12. Effect of Control Mode and Test Rate on the Measured Fracture Toughness of Advanced Ceramics

    Science.gov (United States)

    Hausmann, Bronson D.; Salem, Jonathan A.

    2018-01-01

    The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 µm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.

  13. Results from a Test Fixture for button BPM Trapped Mode Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cameron,P.; Bacha, B.; Blednykh, A.; Pinayev, I.; Singh, O.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.

  14. Measurement variability of quantitative sensory testing in persons with post-stroke shoulder pain.

    Science.gov (United States)

    Lindgren, Ingrid; Ekstrand, Elisabeth; Brogårdh, Christina

    2016-04-28

    To evaluate the measurement variability of quantitative sensory testing (QST) in persons with post-stroke shoulder pain. A test-retest design. Twenty-three persons with post-stroke shoulder pain (median age 65 years). Thermal detection thresholds (cold and warm), pain thresholds (cold and heat) and mechanical pain thresholds (pressure and pin prick) were assessed twice in both arms, 2-3 weeks apart. Measurement variability was analysed with the intraclass correlation coefficient (ICC2.1), the change in mean (đ) with 95% confidence interval (logarithmic scales), and the relative standard error of measurement (SEM%; re-transformed scales). The ICCs for thermal thresholds ranged from 0.48 to 0.89 in the affected (painful) arm and from 0.50 to 0.63 in the unaffected arm, and for mechanical pain thresholds from 0.66 to 0.90 in both arms. No systematic changes in the mean (đ) were found. The SEM% ranged from 4% to 10% for thermal detection and heat pain thresholds, and from 17% to 42% for cold pain and mechanical pain thresholds in both arms. QST measurements, especially cold pain thresholds and mechanical pain thresholds, vary in persons with post-stroke shoulder pain. Before QST can be used routinely to evaluate post-stroke shoulder pain, a test protocol with decreased variability needs to be developed.

  15. Temperature measurements from a horizontal heater test in G-Tunnel

    International Nuclear Information System (INIS)

    Lin, Wunan; Ramirez, A.L.; Watwood, D.

    1991-10-01

    A horizontal heater test was conducted in G-Tunnel, Nevada Test Site, to study the hydrothermal response of the rock mass due to a thermal loading. The results of the temperature measurements are reported here. The measured temperatures agree well with a scoping calculation that was performed using a model which investigates the transport of water, vapor, air, and heat in fractured porous media. Our results indicate that the temperature field might be affected by the initial moisture content of the rock, the fractures in the rock, the distance from the free surface of the alcove wall, and the temperature distribution on the heater surface. Higher initial moisture content, higher fracture density, and cooling from the alcove wall tend to decrease the measured temperature. The temperature on top of the horizontal heater can was about 30 degrees C greater than at the bottom throughout most of the heating phase, causing the rock temperatures above the heater to be greater than those below. Along a radius from the center of the heater, the heating created a dry zone, followed by a boiling zone and condensation zone. Gravity drainage of the condensed water in the condensation zone had a strong effect on the boiling process in the test region. The temperatures below and to the side of the heater indicated a region receiving liquid drainage from an overlying region of condensation. We verified that a thermocouple in a thin-wall tubing measures the same temperature as one grouted in a borehole

  16. Development and testing of an integrated smart tool holder for four-component cutting force measurement

    Science.gov (United States)

    Xie, Zhengyou; Lu, Yong; Li, Jianguang

    2017-09-01

    Cutting force measurement is a significant requirement for monitoring and controlling the machining processes. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this study, an innovative integrated smart tool holder system based on capacitive sensors is designed, constructed and tested, which is capable of measuring triaxial cutting force and a torque simultaneously in a wireless environment system. A standard commercial tool holder is modified to make itself be the force sensing element that has advantages of simple structure and easy machining. Deformable beams are created in the tool holder, and the tiny deformations of which used to calculate the four-component cutting force are detected by six high precision capacitive sensors. All the sensors and other electronics, like data acquisition and transmitting unit, and wireless power unit, are incorporated into the tool holder as a whole system. The device is intended to be used in a rotating spindle such as in milling and drilling processes. Eventually, the static and dynamic characteristics of the smart tool holder have been determined by a series of tests. Cutting tests have also been carried out and the results show it is stable and practical to measure the cutting force in milling and drilling processes.

  17. Accuracy-based proficiency testing for testosterone measurements with immunoassays and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Cao, Zhimin Tim; Botelho, Julianne Cook; Rej, Robert; Vesper, Hubert

    2017-06-01

    Accurate testosterone measurements are needed to correctly diagnose and treat patients. Proficiency Testing (PT) programs using modified specimens for testing can be limited because of matrix effects and usage of non-reference measurement procedure (RMP)-defined targets for evaluation. Accuracy-based PT can overcome such limitations; however, there is a lack of information on accuracy-based PT and feasibility of its implementation in evaluation for testosterone measurements. Unaltered, single-donor human serum from 2 male and 2 female adult donors were analyzed for testosterone by 142 NYSDH-certified clinical laboratories using 16 immunoassays and LC-MS/MS methods. Testosterone target values were determined using an RMP. The testosterone target concentrations for the 4 specimens were 15.5, 30.0, 402 and 498ng/dl. The biases ranged from -17.8% to 73.1%, 3.1% to 21.3%, -24.8% to 8.6%, and -22.1% to 6.8% for the 4 specimens, respectively. Using a total error target of ±25.1%, which was calculated using the minimum allowable bias and imprecision, 73% of participating laboratories had ≥3 of the 4 results within these limits. The variability in total testosterone measurements can affect clinical decisions. Accuracy-based PT can significantly contribute to improving testosterone testing by providing reliable data on accuracy in patient care to laboratories, assay manufacturers, and standardization programs. Copyright © 2017. Published by Elsevier B.V.

  18. Measurements of tokamak fusion test reactor D-T radiation shielding efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Kugel, H.W. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Ascione, G. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Elwood, S. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Gilbert, J. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Ku, L.P. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Levine, J. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Rule, K. [Princeton Univ., NJ (United States). Plasma Physics Lab.; Azziz, N. [USDOE Environmental Measurements Lab., New York (United States); Goldhagen, P. [USDOE Environmental Measurements Lab., New York (United States); Hajnal, F. [USDOE Environmental Measurements Lab., New York (United States); Shebell, P. [USDOE Environmental Measurements Lab., New York (United States)

    1995-03-01

    Measurements of neutron and gamma dose-equivalents were performed in the test cell, at the outer test cell wall, in nearby work areas, and out to the nearest property lines at a distance of 180m. Argon ionization chambers, moderated {sup 3}He proportional counters, and fission chamber detectors were used to obtain measurements of neutron and gamma dose-equivalents per D-T neutron during individual tokamak fusion test reactor (TFTR) discharges. These measured neutron and gamma D-T dose-equivalents per TFTR neutron characterize the effects of local variations in material density resulting from the complex asymmetric site geometry. The measured dose-equivalents per TFTR D-T neutron and the cumulative neutron production were used to determine that the planned annual TFTR neutron production of 1 x 10{sup 21} D-T neutrons is consistent with the design objective of limiting the total dose-equivalent at the property line, from all radiation sources and pathways, to less than 10mrem per year. (orig.).

  19. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  20. Test-retest reliability of daily life gait speed as measured by smartphone global positioning system.

    Science.gov (United States)

    Obuchi, Shuichi P; Tsuchiya, Shuichi; Kawai, Hisashi

    2018-01-30

    Gait speed is useful in predicting adverse health outcomes among older adults. In previous studies, gait speed has typically been measured when subjects walk in laboratory settings, where they are able to intentionally change their gait speed. Thus, it is unclear whether the gait speed captured in a laboratory setting is representative of the subjects' actual walking pace in daily life. This study proposes using the more accurate "daily life gait speed" (DGS), measured as the subject's average gait speed over a week-long period using the global positioning system (GPS) in their smartphone. We examined the test-retest reliability of the DGS measure in the present study. Three daily life gait parameters with 186 volunteers (57 men and 129 women), aged 19 to 84 years, were measured using a smartphone application: DGS, average of daily gait cycle during a week (DCY), and average of daily cadence during a week (DCA). Test-retest reliability of the daily gait parameters between test week (T1) and retest week (T2) was assessed with the intraclass correlation coefficient, ICC (2,1), and systematic biases were observed via Bland-Altman plots. The ICCs between the daily gait parameters at T1 and T2 were 0.902 for DGS, 0.916 for DCY, and 0.917 for DCA. The Bland-Altman plots showed no significant fixed or proportional bias between the measurements at T1 and T2. These results verify that the test-retest reliability of the daily gait parameters in the present study was adequate. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. THE DIFFERENCE BETWEEN MALE AND FEEMALE SDUTENTS IN CERTAIN TEST WHICH WERE MEASURED BY FOOTSCAN SYSTEM

    Directory of Open Access Journals (Sweden)

    Danijela Kuna

    2011-09-01

    Full Text Available Footscan system is an advance technology which allows measuring the pressure applied by a foot on a special platform. With a high speed and resolution, the system allows precise analysis of the pressure discrepancies in all the regions of a foot. With an intention of determining the differences and correlations between the male and female students in the tests for barycenter projection and apportionment of balance through the quadrants of the Footscan system, 32 male and 23 female students between 18 and 20 years of age were tested. Variables causes were constituted by tests for estimation of balance, projections of body’s barycenter location, and the foot’s status measured on Footscan system. According to the results from the correlation matrix, male students had a larger number of important correlations than female students. Analysis of results from multivariate and univariate analysis of variance, important differences were obtained between examinees in the tests for estimation of the balance on one leg and transformation the barycenter left and right, while the general differences between the subsample were not determined. Obtained differences point to the conclusion that there are disparate mechanisms based on which male and female students function in some tests for determination of balance and projection of the barycenter location

  2. Reliability of transverse plane pelvic alignment measurement during the bridge test with unilateral knee extension.

    Science.gov (United States)

    Andrade, Juliana A; Figueiredo, Luisa C; Santos, Thiago R T; Paula, Ana C V; Bittencourt, Natália F N; Fonseca, Sérgio T

    2012-01-01

    The bridge test with unilateral knee extension evaluates the stability of the trunk and pelvis. The evaluation of this stability can contribute to the understanding of the occurrence of musculoskeletal injuries. To investigate the intra- and inter-rater reliability of a qualitative analysis and intra-test reliability of a quantitative analysis of transverse plane pelvic alignment during the bridge test with unilateral knee extension. Thirty participants (24.73±4.24 years old) were tested. The qualitative analysis was conducted by asking two raters to judge the transverse plane pelvic alignment and its reliability was assessed with the weighted kappa coefficient (k(w)). The quantitative analysis was conducted by measuring the greatest pelvic tilt angle in transverse plane and its reliability was assessed by use of the intraclass correlation coefficient (ICC); the mean change, which was evaluated using 95% confidence interval of the mean difference (95%CI d) and Bland-Altman plot; and the quantification of measurement variability, which was assessed using standard error of measurement (SEM) and the coefficient of variation of the typical error (CVTE). In addition, the minimal detectable change (MDC₉₅) was determined. The intra-rater reliability ranged from fair to moderate (k(w)=0.32 to 0.58) and the inter-rater reliability was substantial (k(w)=0.80). The intra-test reliability was excellent (ICC=0.82), the 95%CI d ranged from -0.51º to 1.99º, the SEM was 2.38° and the CV(TE) was 28.75%. The MDC₉₅ was 6.59°. The inter-rater reliability was greater than the intra-rater reliability; the intra-test reliability was excellent and showed no systematic or random error.

  3. Optimized Method for Knee Displacement Measurement in Vehicle Sled Crash Test

    Directory of Open Access Journals (Sweden)

    Sun Hang

    2017-01-01

    Full Text Available This paper provides an optimized method for measuring dummy’s knee displacement in vehicle sled crash test. The proposed method utilizes completely new elements for measurement, which are acceleration and angular velocity of dummy’s pelvis, as well as the rotational angle of its femur. Compared with the traditional measurement only using camera-based high-speed motion image analysis, the optimized one can not only maintain the measuring accuracy, but also avoid the disturbance caused by dummy movement, dashboard blocking and knee deformation during the crash. An experiment is made to verify the accuracy of the proposed method, which eliminates the strong dependence on single target tracing in traditional method. Moreover, it is very appropriate for calculating the penetration depth to the dashboard.

  4. Measurements of electron beam emittance in the Accelerator Test Facility damping ring operated in multibunch modes

    Directory of Open Access Journals (Sweden)

    Yosuke Honda

    2003-09-01

    Full Text Available We present the measurement results of electron beam emittance in the Accelerator Test Facility damping ring operated in multibunch modes. The measurements were carried out with an upgraded laser wire beam profile monitor. The monitor has now a vertical wire as well as a horizontal one and is able to make much faster measurements thanks to an increased effective laser power inside the cavity. The measured emittance shows no large bunch-to-bunch dependence in either the horizontal or vertical directions. The values of the vertical emittance are similar to those obtained in the single-bunch operation. The present results are an important step toward the realization of a high-energy linear collider.

  5. Test battery for measuring the perception and recognition of facial expressions of emotion

    Science.gov (United States)

    Wilhelm, Oliver; Hildebrandt, Andrea; Manske, Karsten; Schacht, Annekathrin; Sommer, Werner

    2014-01-01

    Despite the importance of perceiving and recognizing facial expressions in everyday life, there is no comprehensive test battery for the multivariate assessment of these abilities. As a first step toward such a compilation, we present 16 tasks that measure the perception and recognition of facial emotion expressions, and data illustrating each task's difficulty and reliability. The scoring of these tasks focuses on either the speed or accuracy of performance. A sample of 269 healthy young adults completed all tasks. In general, accuracy and reaction time measures for emotion-general scores showed acceptable and high estimates of internal consistency and factor reliability. Emotion-specific scores yielded lower reliabilities, yet high enough to encourage further studies with such measures. Analyses of task difficulty revealed that all tasks are suitable for measuring emotion perception and emotion recognition related abilities in normal populations. PMID:24860528

  6. A standardization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a standardization work, realized within the Radioprotection Services of the A.E.C., of the physical tests for dectors measuring external irradiations. Among the various tests mentionned, calibration and the establishment of the relative spectral response are treated in details. As far as calibration is concerned, the standardization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the standardization refers to: the reference detector, the radiation sources to be used. High flux detectors and those for pulse electromagnetic radiations are also dealt with [fr

  7. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.

    2013-08-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  8. A Millimeter Scale Flexural Testing System for Measuring the Mechanical Properties of Marine Sponge Spicules.

    Science.gov (United States)

    Monn, Michael A; Ferreira, Jarod; Yang, Jianzhe; Kesari, Haneesh

    2017-10-11

    Many load bearing biological structures (LBBSs)-such as feather rachises and spicules-are small (marine sponge Euplectella aspergillum. The skeletal elements-known as spicules-are silica fibers that are approximately 50 µm in diameter. We describe the procedures for calibrating the mechanical testing device, mounting the spicules on a three-point bending fixture with a ≈1.3 mm span, and performing a bending test. The force applied to the spicule and its deflection at the location of the applied force are measured.

  9. INTRA-RATER RELIABILITY OF USING THE NAVICULAR DROP TEST FOR MEASURING FOOT PRONATION

    OpenAIRE

    Vauhnik, Renata; Turk, Zmago; Pilih, Iztok A.; Mičetić-Turk, Dučanka

    2006-01-01

    The navicular drop test was used as an indicator of foot pronation. It is defined as the distance between the original height of the navicular from the floor, with the foot on the floor in sitting in the subtalar neutral position, and the final weight-bearing position of the navicular in relaxed stance. This measurement is thought to represent the sagittal plane displacement of the navicular bone from a neutral position to a relaxed standing position. The purpose of this study was to test int...

  10. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  11. A test case of the deformation rate analysis (DRA) stress measurement method

    Energy Technology Data Exchange (ETDEWEB)

    Dight, P.; Hsieh, A. [Australian Centre for Geomechanics, Univ. of WA, Crawley (Australia); Johansson, E. [Saanio and Riekkola Oy, Helsinki (Finland); Hudson, J.A. [Rock Engineering Consultants (United Kingdom); Kemppainen, K.

    2012-01-15

    As part of Posiva's site and ONKALO investigations, the in situ rock stress has been measured by a variety of techniques, including hydraulic fracturing, overcoring, and convergence measurements. All these techniques involve direct measurements in a drillhole or at the rock surface. An alternative method is to test drillhole core in a way that enables estimation of the magnitudes and orientations of the in situ rock stress. The Kaiser Effect (KE) and Deformation Rate Analysis (DRA) are two ways to do this. In the work reported here, a 'blind' DRA test was conducted on core obtained from the POSE (Posiva's Olkiluoto Spalling Experiment) niche in the ONKALO. The term 'blind' means that the two first authors of this report, who conducted the tests at the Australian Centre for Geomechanics, did not know the depths below surface at which the cores had been obtained. The results of this DRA Test Case are presented, together with an explanation of the DRA procedure. Also, additional information that would help in such DRA testing and associated analysis is explained. One of the problems in comparing the DRA results with the known Olkiluoto stress field is that the latter is highly variable across the site, as experienced by the previous in situ stress measurements and as predicted by numerical analysis. The variability is mainly caused by the presence of the large brittle deformation zones which perturb the local stress state. However, this variability reduces with depth and the stress field becomes more stable at the {approx} 350 m at which the drillhole cores were obtained. Another compounding difficulty is that the stress quantity, being a second order tensor, requires six independent components for its specification. In other words, comparison of the DRA results and the known stress field requires comparison of six different quantities. In terms of the major principal stress orientation, the DRA results predict an orientation completely

  12. A test case of the deformation rate analysis (DRA) stress measurement method

    International Nuclear Information System (INIS)

    Dight, P.; Hsieh, A.; Johansson, E.; Hudson, J.A.; Kemppainen, K.

    2012-01-01

    As part of Posiva's site and ONKALO investigations, the in situ rock stress has been measured by a variety of techniques, including hydraulic fracturing, overcoring, and convergence measurements. All these techniques involve direct measurements in a drillhole or at the rock surface. An alternative method is to test drillhole core in a way that enables estimation of the magnitudes and orientations of the in situ rock stress. The Kaiser Effect (KE) and Deformation Rate Analysis (DRA) are two ways to do this. In the work reported here, a 'blind' DRA test was conducted on core obtained from the POSE (Posiva's Olkiluoto Spalling Experiment) niche in the ONKALO. The term 'blind' means that the two first authors of this report, who conducted the tests at the Australian Centre for Geomechanics, did not know the depths below surface at which the cores had been obtained. The results of this DRA Test Case are presented, together with an explanation of the DRA procedure. Also, additional information that would help in such DRA testing and associated analysis is explained. One of the problems in comparing the DRA results with the known Olkiluoto stress field is that the latter is highly variable across the site, as experienced by the previous in situ stress measurements and as predicted by numerical analysis. The variability is mainly caused by the presence of the large brittle deformation zones which perturb the local stress state. However, this variability reduces with depth and the stress field becomes more stable at the ∼ 350 m at which the drillhole cores were obtained. Another compounding difficulty is that the stress quantity, being a second order tensor, requires six independent components for its specification. In other words, comparison of the DRA results and the known stress field requires comparison of six different quantities. In terms of the major principal stress orientation, the DRA results predict an orientation completely different to the NW-SE regional

  13. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  14. 3D thermography for improving temperature measurements in thermal vacuum testing

    Science.gov (United States)

    Robinson, D. W.; Simpson, R.; Parian, J. A.; Cozzani, A.; Casarosa, G.; Sablerolle, S.; Ertel, H.

    2017-09-01

    simulator. The results are presented here with estimated temperature measurement uncertainties and defined confidence levels according to the internationally accepted Guide to Uncertainty of Measurement as used in the IEC/ISO17025 test and measurement standard. This work is understood to represent the first application of well-understood thermal imaging theory, commercial photogrammetry software, and open-source ray-tracing software (adapted to realize the Planck function for thermal wavebands and target emission), and to produce from these elements a complete system for determining true surface temperatures for complex spacecraft-testing applications.

  15. TESTING BRAND VALUE MEASUREMENT METHODS IN A RANDOM COEFFICIENT MODELING FRAMEWORK

    Directory of Open Access Journals (Sweden)

    Szõcs Attila

    2014-07-01

    Full Text Available Our objective is to provide a framework for measuring brand equity, that is, the added value to the product endowed by the brand. Based on a demand and supply model, we propose a structural model that enables testing the structural effect of brand equity (demand side effect on brand value (supply side effect, using Monte Carlo simulation. Our main research question is which of the three brand value measurement methods (price premium, revenue premium and profit premium is more suitable from the perspective of the structural link between brand equity and brand value. Our model is based on recent developments in random coefficients model applications.

  16. Design, Fabrication and Temperature Sensitivity Testing of a Miniature Piezoelectric-Based Sensor for Current Measurements

    Directory of Open Access Journals (Sweden)

    Steven B. Lao

    2014-07-01

    Full Text Available Grid capacity, reliability, and efficient distribution of power have been major challenges for traditional power grids in the past few years. Reliable and efficient distribution within these power grids will continue to depend on the development of lighter and more efficient sensing units with lower costs in order to measure current and detect failures across the grid. The objective of this paper is to present the development of a miniature piezoelectric-based sensor for AC current measurements in single conductors, which are used in power transmission lines. Additionally presented in this paper are the thermal testing results for the sensor to assess its robustness for various operating temperatures.

  17. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Stress measurement using magnetic Barkhausen noise and metal magnetic memory testing

    International Nuclear Information System (INIS)

    Wang, Ping; Zhu, Shougao; Tian, Gui Yun; Wang, Haitao; Wang, Xin; Wilson, John

    2010-01-01

    This paper introduces a comparison of the magnetic Barkhausen noise (BN) and metal magnetic memory (MMM) testing techniques for stress measurement. BN has become an important non-destructive technique due to its exceptional material and stress characterization capabilities. MMM is a recently developed technique with special ability for stress detection and stress history. In the applied tensile experiment, BN and MMM signals were acquired via a BN measurement system and EMS-2003 MMM instrument. Relationships between magnetic signals and applied tensile stresses were derived from experiment results. The difference and correlation of the two methods are investigated. Conclusions were derived based on the experiment results

  19. A precise Higgs mass measurement at the ILC and test beam data analyses with CALICE

    International Nuclear Information System (INIS)

    Ruan, Manqi

    2008-01-01

    Utilizing Monte Carlo tools and test-beam data, some basic detector performance properties are studied for the International Linear Collider (ILC). The contributions of this thesis are mainly twofold, first, a study of the Higgs mass and cross section measurements at the ILC (with full simulation to the e + e - → HZ→Hμμ channel and backgrounds); and second, an analysis of test-beam data of the Calorimeter for Linear Collider Experiment (CALICE). For a most general type of Higgs particle with 120 GeV the mass, setting the center-of-mass energy to 230 GeV and with an integrated luminosity of 500fb -1 , a precision of 38.4 MeV is obtained in a model independent analysis for the Higgs boson mass measurement, while the cross section could be measured to 5%; if we make some assumptions about the Higgs boson's decay, for example a Standard Model Higgs boson with a dominant invisible decay mode, the measurement result can be improved by 25% (achieving a mass measurement precision of 29 MeV and a cross section measurement precision of 4%). For the CALICE test-beam data analysis, our work is mainly focused upon two aspects: data quality checks and the track-free ECAL angular measurement. Data quality checks aim to detect strange signals or unexpected phenomena in the test-beam data so that one knows quickly how the overall data taking quality is. They also serve to classify all the data and give useful information for the later offline data analyses. The track-free ECAL angular resolution algorithm is designed to precisely measure the direction of a photon, a very important component in determining the direction of the neutral components in jets. We found that the angular resolution can be well fitted as a function of the square root of the beam energy (in a similar way as for the energy resolution) with a precision of approximately 80 mrad/√(E/GeV) in the angular resolution. (author)

  20. Proficiency tests for evaluation of the 99Tcm measurements in the nuclear medicine

    International Nuclear Information System (INIS)

    Iwahara, Akira; Tauhata, Luiz; Oliveira, Antonio Eduardo de; Nicoli, Ieda Gomes; Alabarse, Frederico Gil; Xavier, Ana Maria

    2009-01-01

    This work performs the performance evaluation of 55 Brazilian nuclear medicine services in activity measurement of radiopharmaceutical containing 99 Tc m . Proficiency tests based on the acceptance criteria of the Regulation ISO/IEC Guide 43-1 and on the accuracy of the brazilian Regulation CNEN-NN-3.05 were applied in 63 results of activity measurements in radionuclide calibrators used by those services. The performance services has shown that the criteria of the ISO/IEC 43-1, nevertheless to be more restrictive, presents results very consistent with the accuracy criteria requested by the Brazilian regulation

  1. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  2. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Avery Island heater tests: measured data for 1000 days of heating

    International Nuclear Information System (INIS)

    Van Sambeek, L.L.; Stickney, R.G.; DeJong, K.B.

    1983-10-01

    Three heater tests were conducted in the Avery Island salt mine. The measurements of temperature and displacement, and the calculation of stress in the vicinity of each heater are of primary importance in the understanding of the thermal and thermomechanical response of the salt to an emplaced heat source. This report presents the temperature, displacement, and calculated stress data gathered during the heating phase of the three heater tests. The data presented have application in the ongoing studies of the response of geologicic media to an emplaced heat source. Specifically, electric heaters, which simulate canisters of heat-generating nuclear waste, were placed in the floor of the Avery Island salt mine, and measurements were made of the response of the salt caused by the heating. The purpose of this report is to transmit the data to the scientific community; rigorous analysis and interpretation of the data are considered beyond the scope of this data report. 11 references, 46 figures

  4. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  5. Measuring the engagement level of children for multiple intelligence test using Kinect

    Science.gov (United States)

    Lee, Dongjin; Yun, Woo han; Park, Chan kyu; Yoon, H.; Kim, Jaehong; Park, C. H.

    2015-02-01

    In this paper, we present an affect recognition system for measuring the engagement level of children using the Kinect while performing a multiple intelligence test on a computer. First of all, we recorded 12 children while solving the test and manually created a ground truth data for the engagement levels of each child. For a feature extraction, Kinect for Windows SDK provides support for a user segmentation and skeleton tracking so that we can get 3D joint positions of an upper-body skeleton of a child. After analyzing movement of children, the engagement level of children's responses is classified into two classes: High or Low. We present the classification results using the proposed features and identify the significant features in measuring the engagement.

  6. System for measurement and automatic regulation of gas flow within an oil aging test device

    Directory of Open Access Journals (Sweden)

    Žigić Aleksandar

    2014-01-01

    Full Text Available This paper describes a system within an oil aging test device that serves for measurement and automatic regulation of gas flow. Following an already realized system that continuously monitors, logs, and regulates transformer oil temperature during the aging process and maintains temperature consistency within strict limits, a model of a flow meter and regulator of air or oxygen through transformer oil samples is developed. A special feature of the implemented system is the measurement of very small gas flows. A short technical description of the realized system is given with a functional block diagram. The basic technical characteristics of the system are specified, and the operating principles and application of the system are described. The paper also gives performance test results in a real exploitation environment.

  7. Do Self Concept Tests Test Self Concept? An Evaluation of the Validity of Items on the Piers Harris and Coopersmith Measures.

    Science.gov (United States)

    Lynch, Mervin D.; Chaves, John

    Items from Peirs-Harris and Coopersmith self-concept tests were evaluated against independent measures on three self-constructs, idealized, empathic, and worth. Construct measurements were obtained with the semantic differential and D statistic. Ratings were obtained from 381 children, grades 4-6. For each test, item ratings and construct measures…

  8. Quantitative sensory testing measures individual pain responses in emergency department patients

    Directory of Open Access Journals (Sweden)

    Duffy KJ

    2017-05-01

    Full Text Available Kevin J Duffy, Katharyn L Flickinger, Jeffrey T Kristan, Melissa J Repine, Alexandro Gianforcaro, Rebecca B Hasley, Saad Feroz, Jessica M Rupp, Jumana Al-Baghli, Maria L Pacella, Brian P Suffoletto, Clifton W Callaway Department of Emergency Medicine, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA Background: Refining and individualizing treatment of acute pain in the emergency department (ED is a high priority, given that painful complaints are the most common reasons for ED visits. Few tools exist to objectively measure pain perception in the ED setting. We speculated that variation in perception of fixed painful stimuli would explain individual variation in reported pain and response to treatment among ED patients. Materials and methods: In three studies, we 1 describe performance characteristics of brief quantitative sensory testing (QST in 50 healthy volunteers, 2 test effects of 10 mg oxycodone versus placebo on QST measures in 18 healthy volunteers, and 3 measure interindividual differences in nociception and treatment responses in 198 ED patients with a painful complaint during ED treatment. QST measures adapted for use in the ED included pressure sensation threshold, pressure pain threshold (PPT, pressure pain response (PPR, and cold pain tolerance (CPT tests. Results: First, all QST measures had high inter-rater reliability and test–retest reproducibility. Second, 10 mg oxycodone reduced PPR, increased PPT, and prolonged CPT. Third, baseline PPT and PPR revealed hyperalgesia in 31 (16% ED subjects relative to healthy volunteers. In 173 (88% ED subjects who completed repeat testing 30 minutes after pain treatment, PPT increased and PPR decreased (Cohen’s dz 0.10–0.19. Verbal pain scores (0–10 for the ED complaint decreased by 2.2 (95% confidence intervals [CI]: 1.9, 2.6 (Cohen’s dz 0.97 but did not covary with the changes in PPT and PPR (r=0.05–0.13. Treatment effects were greatest in ED subjects

  9. FFTF [Fast Flux Test Facility] performance measurements for safety, productivity and control

    International Nuclear Information System (INIS)

    A useful set of performance measurements for Safety, Productivity and Control has evolved at the Fast Flux Test Facility (FFTF). In response to declining budgets and the resulting need to safely manage a manpower rampdown, an ''Early Warning System'' was developed in 1984. Its purpose was to monitor the effects of the staffing rampdown such that appropriate remedial action could be taken to correct adverse trends before a significant problem occurred. 1 tab

  10. Diffuse Prior Monotonic Likelihood Ratio Test for Evaluation of Fused Image Quality Measures

    Science.gov (United States)

    2011-02-01

    score FIQMs with test cases considering over 35 scenes and var - ious image fusion algorithms. Index Terms—Fused image quality measures (FIQM), hypoth...fused via six different algorithms: 1) contrast pyramid A (CONA), 2) contrast pyramid B (CONB) [34], 3) dis- crete wavelet transform (DWTT) [1], [35...36] 4) color discrete wavelet transform (CDWT), 5) color averaging (CLAV), and 6) color multiscale transform (CLMT) [37]. The first three al

  11. Tests and foreseen developments of fibered-OSLD gamma heating measurements in low-power reactors

    Directory of Open Access Journals (Sweden)

    Gruel A.

    2018-01-01

    The feasibility of remote measurements is achieved, whereas further developments could be conducted to improve this technique since the readout procedure still requires to withdraw the OSLD off the gamma flux (hence from the core on account of the dose rate (around a few Gy.h-1, and the readout time remains quite long for on-line applications. Several improvements are foreseen, and will be tested in the forthcoming years.

  12. Nijmegen Continuity Questionnaire: development and testing of a questionnaire that measures continuity of care.

    OpenAIRE

    Uijen, A.A.; Schellevis, F.G.; Bosch, W.J.H.M. van den; Mokkink, H.G.A.; Weel, C. van; Schers, H.J.

    2011-01-01

    Abstract: To develop and pilot test a generic questionnaire to measure continuity of care from the patient's perspective across primary and secondary care settings. We developed the Nijmegen Continuity Questionnaire (NCQ) based on a systematic literature review and analysis of 30 patient interviews. The questionnaire consisted of 16 items about the patient-provider relationship to be answered for five different care providers and 14 items each on the collaboration between four groups of care ...

  13. Situational judgement tests and personality measurement : some answers and more questions

    OpenAIRE

    Judge, Timothy A.; Hofmans, Joeri; Wille, Bart

    2017-01-01

    Abstract: Work psychologists have devoted considerable attention to studying how personality traits can best be conceptualized and assessed in 'high-stakes' contexts such as selection or hiring decisions. Lievens argued that two selection methods, Situational Judgement Tests and Assessment Centre exercises, by standardizing and contextualizing personality measurement, offer many advantages to personality psychology. In hopes of clarifying this argument, we ask two fundamental questions: (1) W...

  14. BENCHMARK EVALUATION OF THE INITIAL ISOTHERMAL PHYSICS MEASUREMENTS AT THE FAST FLUX TEST FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    John Darrell Bess

    2010-05-01

    The benchmark evaluation of the initial isothermal physics tests performed at the Fast Flux Test Facility, in support of Fuel Cycle Research and Development and Generation-IV activities at the Idaho National Laboratory, has been completed. The evaluation was performed using MCNP5 with ENDF/B-VII.0 nuclear data libraries and according to guidelines provided for inclusion in the International Reactor Physics Experiment Evaluation Project Handbook. Results provided include evaluation of the initial fully-loaded core critical, two neutron spectra measurements near the axial core center, 32 reactivity effects measurements (21 control rod worths, two control rod bank worths, six differential control rod worths, two shutdown margins, and one excess reactivity), isothermal temperature coefficient, and low-energy electron and gamma spectra measurements at the core center. All measurements were performed at 400 ºF. There was good agreement between the calculated and benchmark values for the fully-loaded core critical eigenvalue, reactivity effects measurements, and isothermal temperature coefficient. General agreement between benchmark experiment measurements and calculated spectra for neutrons and low-energy gammas at the core midplane exists, but calculations of the neutron spectra below the core and the low-energy gamma spectra at core midplane did not agree well. Homogenization of core components may have had a significant impact upon computational assessment of these effects. Future work includes development of a fully-heterogeneous model for comprehensive evaluation. The reactor physics measurement data can be used in nuclear data adjustment and validation of computational methods for advanced fuel cycle and nuclear reactor systems using Liquid Metal Fast Reactor technology.

  15. Effects of Barometric Fluctuations on Well Water-Level Measurements and Aquifer Test Data

    Energy Technology Data Exchange (ETDEWEB)

    FA Spane, Jr.

    1999-12-16

    The Pacific Northwest National Laboratory, as part of the Hanford Groundwater Monitoring Project, examines the potential for offsite migration of contamination within underlying aquifer systems. Well water-level elevation measurements from selected wells within these aquifer systems commonly form the basis for delineating groundwater-flow patterns (i.e., flow direction and hydraulic gradient). In addition, the analysis of water-level responses obtained in wells during hydrologic tests provides estimates of hydraulic properties that are important for evaluating groundwater-flow velocity and transport characteristics. Barometric pressure fluctuations, however, can have a discernible impact on well water-level measurements. These barometric effects may lead to erroneous indications of hydraulic head within the aquifer. Total hydraulic head (i.e., sum of the water-table elevation and the atmospheric pressure at the water-table surface) within the aquifer, not well water-level elevation, is the hydrologic parameter for determining groundwater-flow direction and hydraulic gradient conditions. Temporal variations in barometric pressure may also adversely affect well water-level responses obtained during hydrologic tests. If significant, adjustments or removal of these barometric effects from the test-response record may be required for quantitative hydraulic property determination. This report examines the effects of barometric fluctuations on well water-level measurements and evaluates adjustment and removal methods for determining areal aquifer head conditions and aquifer test analysis. Two examples of Hanford Site unconfined aquifer tests are examined that demonstrate barometric response analysis and illustrate the predictive/removal capabilities of various methods for well water-level and aquifer total head values. Good predictive/removal characteristics were demonstrated with best corrective results provided by multiple-regression deconvolution methods.

  16. Standard test method for measurement of 235U fraction using enrichment meter principle

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the quantitative determination of the fraction of 235U in uranium using measurement of the 185.7 keV gamma-ray produced during the decay of 235U. 1.2 This test method is applicable to items containing homogeneous uranium-bearing materials of known chemical composition in which the compound is considered infinitely thick with respect to 185.7 keV gamma-rays. 1.3 This test method can be used for the entire range of 235U fraction as a weight percent, from depleted (0.2 % 235U) to highly enriched (97.5 % 235U). 1.4 Measurement of items that have not reached secular equilibrium between 238U and 234Th may not produce the stated bias when low-resolution detectors are used with the computational method listed in Annex A2. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety co...

  17. Measurement uncertainty of dissolution test of acetaminophen immediate release tablets using Monte Carlo simulations

    Directory of Open Access Journals (Sweden)

    Daniel Cancelli Romero

    2017-10-01

    Full Text Available ABSTRACT Analytical results are widely used to assess batch-by-batch conformity, pharmaceutical equivalence, as well as in the development of drug products. Despite this, few papers describing the measurement uncertainty estimation associated with these results were found in the literature. Here, we described a simple procedure used for estimating measurement uncertainty associated with the dissolution test of acetaminophen tablets. A fractionate factorial design was used to define a mathematical model that explains the amount of acetaminophen dissolved (% as a function of time of dissolution (from 20 to 40 minutes, volume of dissolution media (from 800 to 1000 mL, pH of dissolution media (from 2.0 to 6.8, and rotation speed (from 40 to 60 rpm. Using Monte Carlo simulations, we estimated measurement uncertainty for dissolution test of acetaminophen tablets (95.2 ± 1.0%, with a 95% confidence level. Rotation speed was the most important source of uncertainty, contributing about 96.2% of overall uncertainty. Finally, it is important to note that the uncertainty calculated in this paper reflects the expected uncertainty to the dissolution test, and does not consider variations in the content of acetaminophen.

  18. Attention deficits after aneurysmal subarachnoid hemorrhage measured using the test of variables of attention.

    Science.gov (United States)

    Wallmark, Svante; Lundström, Erik; Wikström, Johan; Ronne-Engström, Elisabeth

    2015-05-01

    The aim of this pilot study was to assess attention deficits in patients with aneurysmal subarachnoid hemorrhage using the test of variables of attention (TOVA). This is a computer-based continuous performance test providing objective measures of attention. We also compared the TOVA results with the attention and concentration domains of Montgomery Åsberg Depression Rating Scale and Montreal cognitive assessment, 2 examiner-administrated neuropsychological instruments. Nineteen patients with moderate to good recovery (Glasgow outcome scale, 4-5) were assessed using the TOVA, Montgomery Åsberg Depression Rating Scale, and Montreal cognitive assessment. The measurements were done when the patients visited the hospital for a routine magnetic resonance imaging control of the aneurysm. TOVA performance was pathological in 58%. The dominating pattern was a worsening of performance in the second half of the test, commonly a failing to react to correct stimuli. We found no correlation between TOVA and the performance in concentration and attention domains of Montgomery Åsberg Depression Rating Scale and Montreal cognitive assessment. Attention deficits, measured by the TOVA, were common after subarachnoid hemorrhage. This should be further studied to improve outcome. © 2015 American Heart Association, Inc.

  19. Effect of patient positioning on toe pressure measurement using noninvasive vascular testing.

    Science.gov (United States)

    Sansosti, Laura E; Berger, Michael D; Gerrity, Michael A; Kelly, Patrick; Meyr, Andrew J

    2015-09-01

    Interpretation of digital pressure in the assessment of healing potential for diabetic foot disease has become common because of the potential for false elevation with the ankle-brachial index. However, the specific testing protocol for segmental Doppler examinations and photoplethysmography require patients to be in the supine position, with the lower limbs at heart level, in order to minimise the effect of hydrostatic pressure. This may be difficult in many patients with lower extremity pathology, particularly those who are nonambulatory, with painful wounds, or with orthopnea. In these situations, the noninvasive vascular test may be performed with the patient in a more comfortable position, which may include sitting in a wheelchair with the leg in a dependent position. The objective of this investigation was to evaluate the effect of patient positioning on measurement of the digital pressure. Hallux pressures were measured in 20 healthy volunteers in 3 variable positions of limb dependency. The mean±standard deviation of digital pressure for subjects while lying supine with the limb at heart level was 103.5±26.0 mmHg (the recommended position for performance of the test), while sitting upright with the limb level on the table was 130.6±27.9 mmHg (+26.2%, pposition was 169.8±30.8 mmHg (+64.1%, ppositioning has a significant effect on measurement of digital pressure.

  20. Proposal for a Universal Test Mirror for Characterization of Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Warwick, Tony; Noll, Tino; Siewert, Frank; Zeschke, Thomas; Geckeler, Ralf D.

    2007-01-01

    The development of third generation light sources like the Advanced Light Source (ALS) or BESSY II brought to a focus the need for high performance synchrotron optics with unprecedented tolerances for slope error and micro roughness. Proposed beam lines at Free Electron Lasers (FEL) require optical elements up to a length of one meter, characterized by a residual slope error in the range of 0.1mu rad (rms),and rms values of 0.1 nm for micro roughness. These optical elements must be inspected by highly accurate measuring instruments, providing a measurement uncertainty lower than the specified accuracy of the surface under test. It is essential that metrology devices in use at synchrotron laboratories be precisely characterized and calibrated to achieve this target. In this paper we discuss a proposal for a Universal Test Mirror (UTM) as a realization of a high performance calibration instrument. The instrument would provide an ideal calibration surface to replicate a redundant surface under test of redundant figure. The application of a sophisticated calibration instrument will allow the elimination of the majority of the systematic error from the error budget of an individual measurement of a particular optical element. We present the limitations of existing methods, initial UTM design considerations, possible calibration algorithms, and an estimation of the expected accuracy

  1. Experimental testing of the digital multichannel analyzer for gamma spectrometry measurements

    International Nuclear Information System (INIS)

    Novkovic, D.; Nadjdjerdj, L.; Kandic, A.; Vukanac, I.; Djurasevic, M.

    2008-01-01

    The results of experimental testing of the digital multichannel analyzer which digitalizes the signal after a preamplifier are presented. The recordings of some of the characteristics of the spectrometer containing a digital MCA, such as full-peak efficiency, net-area ratio of the two peaks and the stability of the peak position, were carried out under different input counting rates, with different radioactive sources. The tested MCA has shown some excellent features, like the stability of the peak position over a long-term period and flexibility in the adjusting of optimum measurement conditions. However, the performed tests have also shown some serious and unexpected disadvantages of the digital MCA when it operates under certain circumstances, one of them having to do with the automatic tuning of live-time correction at low-input counting rates. (author)

  2. Solar Sail Models and Test Measurements Correspondence for Validation Requirements Definition

    Science.gov (United States)

    Ewing, Anthony; Adams, Charles

    2004-01-01

    Solar sails are being developed as a mission-enabling technology in support of future NASA science missions. Current efforts have advanced solar sail technology sufficient to justify a flight validation program. A primary objective of this activity is to test and validate solar sail models that are currently under development so that they may be used with confidence in future science mission development (e.g., scalable to larger sails). Both system and model validation requirements must be defined early in the program to guide design cycles and to ensure that relevant and sufficient test data will be obtained to conduct model validation to the level required. A process of model identification, model input/output documentation, model sensitivity analyses, and test measurement correspondence is required so that decisions can be made to satisfy validation requirements within program constraints.

  3. Experimental testing of the digital multichannel analyzer for gamma spectrometry measurements

    Directory of Open Access Journals (Sweden)

    Novković Dušan

    2008-01-01

    Full Text Available The results of experimental testing of the digital multichannel analyzer which digitalizes the signal after a preamplifier are presented. The recordings of some of the characteristics of the spectrometer containing a digital MCA, such as full-peak efficiency, net area ratio of the two peaks and the stability of the peak position, were carried out under different input counting rates, with different radioactive sources. The tested MCA has shown some excellent features, like the stability of the peak position over a long-term period and flexibility in the adjusting of optimum measurement conditions. However, the performed tests have also shown some serious and unexpected disadvantages of the digital MCA when it operates under certain circumstances, one of them having to do with the automatic tuning of live-time correction at low-input counting rates.

  4. TESTING CASC SCALE FOR MEASURING EMOTIONAL AND RATIONAL ADVERTISING AND MEDIA EFFECTS

    Directory of Open Access Journals (Sweden)

    Nevenka Podgornik

    2013-05-01

    Full Text Available Researching effects of media and advertising demands a search for a cost efficient, quick and verified method of testing the its emotional as well as rational effects on consumers. Thus a CASC (Communication Analytic and Syncretic Cognitions scale was developed to meassure advertising effects and was selected for testing. In an extended research presented in this paper and based on 988 respondents evaluating 15 different ads we provided evidence that verify this scale on four different groups of ad motives. In addition we have tested individual ads and their complience with the suggested motives based on the theory and the four separate components (rational component, primary emotions, pro-social emotions and individualistic emotions. The findings confirm that CASC scale is able to detect differences between different motives and is thus an effective tool for measuring advertising effects.

  5. Testing measurement invariance of the Learning Programme Management and Evaluation scale across academic achievement

    Directory of Open Access Journals (Sweden)

    Maelekanyo C. Mulaudzi

    2016-10-01

    Full Text Available Orientation: Measurement invariance is one of the most precarious aspects of the scale development process without which the interpretation of research findings on population subgroups may be ambiguous and even invalid. Besides tests for validity and reliability, measurement invariance represents the hallmark for psychometric compliance of a new measuring instrument and provides the basis for inference of research findings across a range of relevant population sub-groups. Research purpose: This study tested the measurement invariance of a Learning Programme Management and Evaluation (LPME scale across levels of academic achievement. Motivation for the study: It is important for any researcher involved in new scale development to ensure that the measurement instrument and its underlying constructs have proper structural alignment and that they both have the same level of meaning and significance across comparable heterogeneous groups. Research design, approach and method: A quantitative, non-experimental, cross-sectional survey design was used, and data were obtained from 369 participants who were selected from three public sector organisations using a probabilistic simple random sampling technique. The Statistical Package for Social Sciences and Analysis of Moment Structures software (versions 21.0.0 were used to analyse the data. Main findings: The findings show that all the four invariance models tested have achieved acceptable goodness-of-fit indices. Furthermore, the findings show that the factorial structure of the LPME scale and the meaning of its underlying constructs are invariant across different levels of academic achievement for human resource development (HRD practitioners and learners or apprentices involved in occupational learning programmes. Practical implications: The findings of this study suggest practical implications for HRD scholars as they are enabled to make informed decisional balance comparisons involving educational

  6. Cyclic flattened Brazilian disc tests for measuring the tensile fatigue properties of brittle rocks.

    Science.gov (United States)

    Liu, Yi; Dai, Feng; Xu, Nuwen; Zhao, Tao

    2017-08-01

    We propose a cyclic flattened Brazilian disc (FBD) testing method to measure the tensile fatigue properties of brittle rocks. Our method has obvious merits in its specimen preparation and experimental operation. Two parallel flattens are introduced in the disc specimen, which facilitate easily and uniformly loading the specimen without special loading devices required. Moreover, the contact regions between two flattens and loading planes barely change during the entire loading and unloading process, ensuring a consistent contact condition. With certain appropriate loading angles, this method guarantees that the very first breakage of the specimen occurs at the center of the disc, which is the prerequisite of the Brazilian-type indirect tensile tests. To demonstrate our new method, nine cyclic FBD tensile tests are conducted. The fatigue load-deformation characteristics of FBD specimens are revealed. The tensile fatigue lives of tested specimens are observed to increase with the increase in cyclic loading frequency. Our proposed method provides a convenient and reliable approach to indirectly measure the fatigue tensile properties of brittle rocks and other brittle solids subjected to cyclic tensile loadings.

  7. Hydraulic tests with measuring and control plug for KNK II temperature transient experiments (TETRA)

    International Nuclear Information System (INIS)

    Reimann, G.; Grossgarten, H.-D.; Heckert, K.

    1985-07-01

    For the temperature transient experiments (TETRA) at KNK II the sodium flow rate of a 19-pin test bundle integrated in an annular fuel element shall be reduced and the coolant temperature consequently increased with the help of a measuring and control plug. A valve will act as orificing device. It is designed in such a way that even in closed condition a remaining mass flow will be given, with which the aimed maximum coolant temperature of 750 deg. C will be reached at the outlet of the test bundle. With the nominal mass flow of the test bundle of 1.35 kg/s and a core pressure drop of 1.33 bar, for the test operation with maximum coolant outlet temperature a minimum mass flow of 0.76 kg/s and a test element pressure drop of 0.4 bar is calculated. The experimental plug has therefore to provide a pressure drop of 0.9 bar. During the hydraulic tests the pressure drop of the plug and the characteristic of the valve had to be determined. For this purpose a test line with the same inner dimensions and installations as the plug was established and a first series of experiments was performed in a water circuit. The experiments showed that most of the pressure drop was caused by the valve. It amounts to 0.5 bar with the minimum mass flow, i.e. the aimed pressure drop of 0.9 bar is not yet reached. Further tests will be performed with smaller ring gaps of the valve. In a second series of experiments the characteristics of four valves with different geometries have been determined

  8. Validity of critical frequency test for measuring table tennis aerobic endurance through specific protocol.

    Science.gov (United States)

    Zagatto, Alessandro M; Papoti, Marcelo; Gobatto, Claudio A

    2008-01-01

    The aim of this study was to validate critical frequency specific test (critf) for the estimation of the aerobic endurance in table tennis players. Eight male international-level table tennis players participated of this study. Specific tests were applied by using a mechanical ball thrower to control the intensity of the exercise. The critf was determined by applying three or four series of exercises to exhaustion (Tlim). The critf was evaluated by using lactate steady state test (90, 100, and 106 % of critf intensity). The other specific test was an incremental protocol used to determine the anaerobic threshold (AnTBI) and the onset of blood lactate accumulation (OBLA) using a ball thrower. The critf (39.87 ± 3.31 balls·min(-1)) was not significantly different among AnTBI (48.11 ± 7.36 balls·min(- 1)) and OBLA3.5 (49.36 ± 12.04 balls·min(-1)) frequencies and it was correlated with AnTBI parameter (r = 0.78). At frequencies of the 90 and 100% of critf a dynamic equilibrium was verified in lactate concentration between the eighth and twentieth minutes. However, this dynamic equilibrium was not found at 106% intensity. The data indicate that in table tennis the critf model can be used for measuring the aerobic endurance. Key pointsIn table tennis is need the use of a specific protocol for evaluation of the aerobic endurance.The critical frequency test in table tennis seems to represent the intensity of maximal equilibrium of lactatemia.The critical frequency test can be used for measuring table tennis aerobic endurance through specific protocol.

  9. The COPD assessment test correlates well with the computed tomography measurements in COPD patients in China.

    Science.gov (United States)

    Zhang, Yan; Tu, You-Hui; Fei, Guang-He

    2015-01-01

    The chronic obstructive pulmonary disease (COPD) assessment test (CAT) is a validated simple instrument to assess health status, and it correlates well with the severity of airway obstruction in COPD patients. However, little is known about the relationships between CAT scores and quantitative computed tomography (CT) measurements of emphysema and airway wall thickness in COPD patients in the People's Republic of China. One hundred and twelve participants including 63 COPD patients and 49 normal control subjects were recruited. All participants were examined with high-resolution CT to get the measurements of emphysema (percentage of pixels below -950 HU [%LAA-950]) and airway wall thickness (wall area percentage and the ratio of airway wall thickness to total diameter). Meanwhile, they completed the CAT and modified Medical Research Council questionnaire independently. Significantly higher CAT scores and CT measurements were found in COPD patients compared with normal control subjects (P<0.05), and there was a tendency of higher CAT scores and CT measurements with increasing disease severity measured by GOLD staging system. Positive correlations were found between CAT scores and CT measurements (P<0.01). Using multiple linear stepwise regression, CAT score =-46.38+0.778× (wall area percentage) +0.203× (%LAA-950) (P<0.001). Meanwhile, CAT scores and CT measurements in COPD patients all positively correlated with the modified Medical Research Council grades and negatively correlated with FEV1% (P<0.01). CAT scores correlate well with the quantitative CT measurements in COPD patients, which may provide an imaging evidence that the structural changes of the lungs in this disease are associated with the health status measured by CAT.

  10. Blowdown mass flow measurements during the Power Burst Facility LOC-11C test

    International Nuclear Information System (INIS)

    Broughton, J.M.; MacDonald, P.E.

    1979-01-01

    An interpretation and evaluation of the two-phase coolant mass flow measurements obtained during Test LOC-11C performed in the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory (INEL) are presented. Although a density gradient existed within the pipe between 1 and 6 s, the homogeneous flow model used to calculate the coolant mass flow from the measured mixture density, momentum flux, and volumetric flow was found to be generally satisfactory. A cross-sectional average density was determined by fitting a linear density gradient through the upper and lower chordal densities obtained from a three-beam gamma densitometer and then combining the result with the middle beam density. The integrated measured coolant mass flow was subsequently found to be within 5% if the initial mass inventory of the PBF loss-of-coolant accident (LOCA) system. The posttest calculations using the RELAP4/MOD6 computer code to determine coolant mass flow for Test LOC-11C also agreed well with the measured data

  11. Tests and foreseen developments of fibered-OSLD gamma heating measurements in low-power reactors

    Science.gov (United States)

    Gruel, A.; Guillou, M. Le; Blaise, P.; Destouches, C.; Magne, S.

    2018-01-01

    In this paper are presented test measurements of a fibered-OSLD system performed during a dedicated experimental phase in EOLE zero-power reactor. The measurement setup consists of an OSLD crystal connected onto the extremity of an optical fiber and a laser stimulation system, manufactured by the CEA/LIST in Saclay. The OSL sensor is remotely stimulated via an optical fiber using a diode-pumped solid-state laser. The OSL light is collected and guided back along the same fiber to a photomultiplier tube. Results obtained using this system are compared to usual gamma heating measurement protocol using OSLD pellets. The presence of induced radio-luminescence in the OSLD during the irradiation was also observed and could be used to monitor the gamma flux. The feasibility of remote measurements is achieved, whereas further developments could be conducted to improve this technique since the readout procedure still requires to withdraw the OSLD off the gamma flux (hence from the core) on account of the dose rate (around a few Gy.h-1), and the readout time remains quite long for on-line applications. Several improvements are foreseen, and will be tested in the forthcoming years.

  12. Validation Tests of Fiber Optic Strain-Based Operational Shape and Load Measurements

    Science.gov (United States)

    Bakalyar, John A.; Jutte, Christine

    2012-01-01

    Aircraft design has been progressing toward reduced structural weight to improve fuel efficiency, increase performance, and reduce cost. Lightweight aircraft structures are more flexible than conventional designs and require new design considerations. Intelligent sensing allows for enhanced control and monitoring of aircraft, which enables increased structurally efficiency. The NASA Dryden Flight Research Center (DFRC) has developed an instrumentation system and analysis techniques that combine to make distributed structural measurements practical for lightweight vehicles. Dryden's Fiber Optic Strain Sensing (FOSS) technology enables a multitude of lightweight, distributed surface strain measurements. The analysis techniques, referred to as the Displacement Transfer Functions (DTF) and Load Transfer Functions (LTF), use surface strain values to calculate structural deflections and operational loads. The combined system is useful for real-time monitoring of aeroelastic structures, along with many other applications. This paper describes how the capabilities of the measurement system were demonstrated using subscale test articles that represent simple aircraft structures. Empirical FOSS strain data were used within the DTF to calculate the displacement of the article and within the LTF to calculate bending moments due to loads acting on the article. The results of the tests, accuracy of the measurements, and a sensitivity analysis are presented.

  13. Test of Horizontal Magnetic Field Measurements in the Presence of a Strong Vertical Field

    CERN Document Server

    Vasserman, Isaac

    2004-01-01

    Trajectory straightness is an important parameter defining the performance of free-electron laser (FEL) devices. The first test of horizontal field measurements using Hall probes was done in 1998 as a preparation to the tuning of undulators for the FEL project at the Advanced Photon Source. This work continues the 1998 work, now associated with Linac Coherent Light Source (LCLS) project. Tolerances for the LCLS FEL undulator specify 2 um trajectory excursion in both (horizontal and vertical) planes for a particle energy of 14.1 GeV, which means that measurements of a small horizontal field in presence of strong (up to 1.5 T) vertical field are required. Hall probe measurements under such conditions are complicated due to a planar Hall probe effect. Previous tests done in 1998 showed that a 2- axis Sentron probe is a possible choice. The high sensitivity of horizontal field integrals to the vertical position of the sensor was observed. It was shown that this probe could be used for fast measurements and tuning...

  14. A more general model for testing measurement invariance and differential item functioning.

    Science.gov (United States)

    Bauer, Daniel J

    2017-09-01

    The evaluation of measurement invariance is an important step in establishing the validity and comparability of measurements across individuals. Most commonly, measurement invariance has been examined using 1 of 2 primary latent variable modeling approaches: the multiple groups model or the multiple-indicator multiple-cause (MIMIC) model. Both approaches offer opportunities to detect differential item functioning within multi-item scales, and thereby to test measurement invariance, but both approaches also have significant limitations. The multiple groups model allows 1 to examine the invariance of all model parameters but only across levels of a single categorical individual difference variable (e.g., ethnicity). In contrast, the MIMIC model permits both categorical and continuous individual difference variables (e.g., sex and age) but permits only a subset of the model parameters to vary as a function of these characteristics. The current article argues that moderated nonlinear factor analysis (MNLFA) constitutes an alternative, more flexible model for evaluating measurement invariance and differential item functioning. We show that the MNLFA subsumes and combines the strengths of the multiple group and MIMIC models, allowing for a full and simultaneous assessment of measurement invariance and differential item functioning across multiple categorical and/or continuous individual difference variables. The relationships between the MNLFA model and the multiple groups and MIMIC models are shown mathematically and via an empirical demonstration. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Measurement of psychological factors associated with genetic testing for hereditary breast, ovarian and colon cancers.

    Science.gov (United States)

    Vadaparampil, Susan T; Ropka, Mary; Stefanek, Michael E

    2005-01-01

    Despite numerous individual studies of psychological factors (depression, anxiety, distress) related to genetic testing for inherited cancer syndromes (CGT), there has been no systematic review of the psychological factors are measured among individuals at increased risk for hereditary breast, ovarian, or colon cancer. Our review provides an analysis of psychological factors in studies of CGT and discusses the instruments most commonly used to measure them. We performed a literature search using three major OVID databases from 1993 to January 2003. In the 19 studies that met our inclusion criteria, the most commonly assessed psychological factors were distress, anxiety, and depression. These factors were most often measured by the impact of event scale (IES), the state-trait anxiety inventory (STAI), and the Centers for Epidemiologic Studies and Depression scale (CES-D), respectively. Our results show deficits in the existing body of literature on psychological factors associated with CGT including limited documentation of psychometrics and variability in instrumentation.

  16. Detailed measurements and modelling of thermo active components using a room size test facility

    DEFF Research Database (Denmark)

    Weitzmann, Peter; Svendsen, Svend

    2005-01-01

    measurements in an office sized test facility with thermo active ceiling and floor as well as modelling of similar conditions in a computer program designed for analysis of building integrated heating and cooling systems. A method for characterizing the cooling capacity of thermo active components is described...... based on measurements of the energy balance of the thermo active deck. A cooling capacity of around 60W/m² at a temperature difference of 10K between room and fluid temperature has been found. It is also shown, that installing a lowered acoustic ceiling covering around 50% of the ceiling surface area...... only causes a reduction in the cooling capacity of around 10%. At the same time, the simulation model is able to reproduce the results from the measurements. Especially the heat flows are well predicted with a deviation of only a few percent, while the temperatures are not as well predicted, though...

  17. Lifetime Measurements of $ \\pi ^+ \\pi ^- $ and $\\pi^{+-} K^{-+}$ Atoms to Test Low-Energy QCD Predictions

    CERN Multimedia

    Iliescu, M A; Ponta, T C; Dumitriu, D E; Afanasyev, L; Zhabitskiy, M; Rykalin, V; Hons, Z; Schacher, J; Yazkov, V; Gerndt, J; Detraz, C C; Guaraldo, C; Dreossi, D; Smolik, J; Gorchakov, O; Nikitin, M; Dudarev, A; Kluson, J; Hansroul, M; Okada, K; Constantinescu, S; Kruglov, V; Komarov, V; Takeutchi, F; Tarta, P D; Kuptsov, A; Nemenov, L; Karpukhin, V; Shliapnikov, P; Brekhovskikh, V; Saborido silva, J J; Drijard, D; Rappazzo, G F; Pentia, M C; Gugiu, M M; Kruglova, L; Pustylnik, Z; Trojek, T; Duma, M; Ciocarlan, C; Kulikov, A; Ol'shevskiy, V; Ryazantsev, A; Chiba, M; Anania, A; Tarasov, A; Gritsay, K; Lapchine, V; Cechak, T; Vrba, T; Lopez aguera, A

    2002-01-01

    %PS212 \\\\ \\\\ The proposed experiment aims to measure the lifetime of $ \\pi ^+ \\pi ^- $ atoms in the ground state with 10\\% precision, using the 24~GeV/c proton beam of the CERN Proton Synchrotron. As the value of the above lifetime of order 10$ ^- ^{1} ^{5} $s is dictated by a strong interaction at low energy, the precise measurement of this quantity enables to determine a combination of S-wave pion scattering lengths to 5\\%. Pion scattering lengths have been calculated in the framework of chiral perturbation theory and values predicted at the same level of accuracy have, up to now, never been confronted with accurate experimental data. Such a measurement would submit the understanding of chiral symmetry breaking of QCD to a crucial test.

  18. Design, Development and Testing of a Semi Cylindrical Capacitive Sensor for Liquid Level Measurement

    Directory of Open Access Journals (Sweden)

    Sagarika PAL

    2010-05-01

    Full Text Available In the present paper a low cost noncontact semi cylindrical capacitive type liquid level sensor has been designed, developed and tested. The semi cylindrical capacitive sensor consisting of two thin semi cylindrical metal plates separated by a gap distance and mounted around a non conducting storage tank, has been used to measure the liquid level in the tank. The measured capacitance variation with variation of liquid level is linear and obtained in the nano farad range which again has been converted into voltage variation by using proper signal conditioning circuit. Since the sensor is noncontact type it can be used for both conducting and non conducting type of liquid contained within a non conducting tank. For converting the capacitance variation in to voltage variation a series R-L-C resonating circuit has been used instead of conventional bridge circuit. Experimental results confirm the satisfactory performance of the sensor for liquid level measurement.

  19. Performance-based tests in subjects with stroke: outcome scores, reliability and measurement errors.

    Science.gov (United States)

    Faria, Christina D C M; Teixeira-Salmela, Luci F; Neto, Mansueto Gomes; Rodrigues-de-Paula, Fátima

    2012-05-01

    To assess the intra- and inter-rater reliabilities and measurement errors of seven widely applied performance-based tests for stroke subjects (comfortable/maximal gait speeds and both stair ascending/descending cadences, as well as the Timed 'Up and Go' test) and to verify whether the use of different types of outcome scores (one trial, the means of two and three trials, and the best and the worst values of the three trials) affected the score values, as well as their reliability and measurement errors. Intra- and inter-rater reliability study. Research laboratory. Sixteen stroke subjects with a mean age of 52 ± 17.9 years. Seven performance-based tests, over two sessions, seven days apart, evaluated by two independent examiners. A third examiner recorded all data. One-way ANOVAs, intra-class correlation coefficients (ICCs) and percentages of the standard errors of measurement (SEM%) were used for analyses. For all tests, similar results were found for all types of outcome scores (0.01 ≤ F ≤ 0.56; 0.34 ≤ p ≤ 0.99). For instance, at the comfortable gait speed, the means (SD) values for the first trial, the means of two and three trials and the best and worst of three trials were, respectively, 1.04 (0.25), 1.04(0.24), 1.05 (0.24), 1.10 (0.26), 1.02 (0.24) seconds. Significant and adequate values of intra- (0.75 ≤ ICC ≤ 0.96; p ≤ 0.002) and inter-rater (0.75 ≤ ICC ≤ 0.97; p ≤ 0.001) reliabilities were found for all tests and outcome scores. Measurement errors were considered low (5.01 ≤ SEM% ≤14.78) and were also similar between all outcome scores. For the seven tests, only one trial was necessary to provide consistent and reliable results regarding the functional performances of stroke subjects.

  20. Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

    International Nuclear Information System (INIS)

    Very, F.; Rosenkrantz, E.; Combette, P.; Ferrandis, J.Y.; Fourmentel, D.; Destouches, C.; Villard, J.F.

    2015-01-01

    The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m -2 .K -1 and 130 μC.N -1 for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in order to

  1. Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

    Energy Technology Data Exchange (ETDEWEB)

    Very, F.; Rosenkrantz, E.; Combette, P.; Ferrandis, J.Y. [University Montpellier, IES, UMR 5214, F-34000, Montpellier (France); CNRS, IES, UMR 5214, F-34000, Montpellier (France); Fourmentel, D.; Destouches, C.; Villard, J.F. [CEA, DEN, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St Paul lez Durance (France)

    2015-07-01

    The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m{sup -2}.K{sup -1} and 130 μC.N{sup -1} for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in

  2. Development of an item bank for computerized adaptive test (CAT) measurement of pain.

    Science.gov (United States)

    Petersen, Morten Aa; Aaronson, Neil K; Chie, Wei-Chu; Conroy, Thierry; Costantini, Anna; Hammerlid, Eva; Hjermstad, Marianne J; Kaasa, Stein; Loge, Jon H; Velikova, Galina; Young, Teresa; Groenvold, Mogens

    2016-01-01

    Patient-reported outcomes should ideally be adapted to the individual patient while maintaining comparability of scores across patients. This is achievable using computerized adaptive testing (CAT). The aim here was to develop an item bank for CAT measurement of the pain domain as measured by the EORTC QLQ-C30 questionnaire. The development process consisted of four steps: (1) literature search, (2) formulation of new items and expert evaluations, (3) pretesting and (4) field-testing and psychometric analyses for the final selection of items. In step 1, we identified 337 pain items from the literature. Twenty-nine new items fitting the QLQ-C30 item style were formulated in step 2 that were reduced to 26 items by expert evaluations. Based on interviews with 31 patients from Denmark, France and the UK, the list was further reduced to 21 items in step 3. In phase 4, responses were obtained from 1103 cancer patients from five countries. Psychometric evaluations showed that 16 items could be retained in a unidimensional item bank. Evaluations indicated that use of the CAT measure may reduce sample size requirements with 15-25% compared to using the QLQ-C30 pain scale. We have established an item bank of 16 items suitable for CAT measurement of pain. While being backward compatible with the QLQ-C30, the new item bank will significantly improve measurement precision of pain. We recommend initiating CAT measurement by screening for pain using the two original QLQ-C30 pain items. The EORTC pain CAT is currently available for "experimental" purposes.

  3. PIV Measurement of Isothermal Flow in the Moderator Circulation Test (MCT) Facility

    Energy Technology Data Exchange (ETDEWEB)

    Im, Sunghyuk; Sung, Hyung Jin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Seo, Han; Bang, In Cheol [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of); Kim, Hyoung Tae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    One of the important design features of a CANDU reactor (a pressurize heavy water reactor) is the use of moderator as a heat sink during some postulated accidents such as a large break Loss Of Coolant Accident (LOCA). If the moderator available subcooling at the onset of a large LOCA is greater than the subcooling requirements, a sustained calandria tube dryout is avoided. The subcooling requirements are determined from a set of experiments known as the fuel channel contact boiling experiments. The difference between available subcooling and required subcooling is called subcooling margins. The local temperature of the moderator is a key parameter in determining the available subcooling. To predict the local temperature in the calandria, Korea Atomic Energy Research Institute (KAERI) started the experimental research on moderator circulation as one of a national R and D research programs from 2012. In the present work the test vessel is equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV is performed under the iso-thermal test conditions. The 2D velocity is measured on the cross-sectional plane normal to the axial direction of the tank. The PIV measurement results could capture the same flow pattern as that expected in the CANDU6 calandria tank under momentum dominant flow condition, where the inlet jets penetrate to the top of the tank and produce a downward flow through the center of the tube columns towards the outlet nozzle and the flow fields are in symmetric distributions. The measurements of downward velocities are performed at different locations. The velocity is shown to be axially uniform. The velocity is rapidly decreased as the measurement location is far from the center of tank, since the downward flow is dominant along the center of the tube columns. More experimental works for the iso-thermal conditions as well as the heating conditions will be performed using PIV measurement in the

  4. PIV Measurement of Isothermal Flow in the Moderator Circulation Test (MCT) Facility

    International Nuclear Information System (INIS)

    Im, Sunghyuk; Sung, Hyung Jin; Seo, Han; Bang, In Cheol; Kim, Hyoung Tae

    2014-01-01

    One of the important design features of a CANDU reactor (a pressurize heavy water reactor) is the use of moderator as a heat sink during some postulated accidents such as a large break Loss Of Coolant Accident (LOCA). If the moderator available subcooling at the onset of a large LOCA is greater than the subcooling requirements, a sustained calandria tube dryout is avoided. The subcooling requirements are determined from a set of experiments known as the fuel channel contact boiling experiments. The difference between available subcooling and required subcooling is called subcooling margins. The local temperature of the moderator is a key parameter in determining the available subcooling. To predict the local temperature in the calandria, Korea Atomic Energy Research Institute (KAERI) started the experimental research on moderator circulation as one of a national R and D research programs from 2012. In the present work the test vessel is equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV is performed under the iso-thermal test conditions. The 2D velocity is measured on the cross-sectional plane normal to the axial direction of the tank. The PIV measurement results could capture the same flow pattern as that expected in the CANDU6 calandria tank under momentum dominant flow condition, where the inlet jets penetrate to the top of the tank and produce a downward flow through the center of the tube columns towards the outlet nozzle and the flow fields are in symmetric distributions. The measurements of downward velocities are performed at different locations. The velocity is shown to be axially uniform. The velocity is rapidly decreased as the measurement location is far from the center of tank, since the downward flow is dominant along the center of the tube columns. More experimental works for the iso-thermal conditions as well as the heating conditions will be performed using PIV measurement in the

  5. [Does the Fragmented Images Test measure locally oriented visual processing in autism spectrum disorders?].

    Science.gov (United States)

    Scheurich, Armin; Fellgiebel, Andreas; Müller, Mattias J; Poustka, Fritz; Bölte, Sven

    2010-03-01

    The cognitive phenotype of autism spectrum disorders (ASD) is characterized among other things by local processing (weak central coherence). It was examined whether a test that measures identification of fragmented pictures (FBT) is able to seize this preference for local processing. The FBT performance of 15 patients with ASD, 16 with depression, 16 with schizophrenia and of 16 control subjects was compared. In addition, two tests well known to be sensitive to local processing were assessed, namely the Embedded Figures Test (EFT) and the Block Design Test (BDT). ASD patients demonstrated a preference for local processing. Difficulties in global processing, or more specifically in gestalt perception (FBT), were accompanied by good performance on the EFT and BDT as expected. Controlling for age and nonverbal intelligence (ANCOVA) reduced differences to trends. However, the calculation of difference scores (i.e., subtraction of FBT from EFT performance) resulted in significant differences between ASD and control groups even after controlling for of age and intelligence. The FBT is a suitable exploratory test of local visual processing in ASD. In particular, a difference criterion can be generated (FBT vs. EFT) that discriminates between ASD and clinical as well as healthy control groups.

  6. Optimization of an Optical Test Bench for Tire Properties Measurement and Tread Defects Characterization

    Directory of Open Access Journals (Sweden)

    Juan Jesús Castillo Aguilar

    2017-03-01

    Full Text Available Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures.

  7. Correlation between the results of three physical fitness tests (endurance, strength, speed) and the output measured during a bicycle ergometer test in a cohort of military servicemen.

    Science.gov (United States)

    Sammito, Stefan; Gundlach, Nils; Böckelmann, Irina

    2016-01-01

    Physical fitness tests are widely used to assess endurance, sprint ability, coordination and/or strength. The objective of the present study was to analyze the degree to which the results of the Bundeswehr Basis Fitness Test (BFT)--a physical fitness test comprising a sprint test (11 × 10-m shuttle test), a flexed-arm hang test and a 1000-m run--are consistent with the output measured during a bicycle ergometer test. The number of false-positive and false-negative results with regard to the assessment of physical fitness were also examined. As part of a retrospective study, health assessments from 323 reenlistment examinations were evaluated regarding the output measured during a bicycle ergometer test and compared with the BFT results of the candidates. Overall, a good correlation was shown between the bicycle ergometer test results and the results achieved in the BFT disciplines. All three disciplines of the BFT showed a highly significant correlation with the relative output achieved during the bicycle ergometer test (P < 0.001), and also, the overall BFT score was highly significantly correlated (P < 0.001). The overall rate of false-positive and false-negative results was 4.0 %. The BFT results measured in the three physical fitness test items were highly correlated with the output measured during the bicycle ergometer tests. The rate of false-positive and false-negative results was low. The test items thus represent an appropriate measurement instrument because the test items require few equipment and less time. Additionally, a large number of subjects can be assessed. We suggest that it would be more useful to assess the physical fitness of this special group exclusively on the basis of the BFT instead of using the bicycle ergometer test.

  8. Test-retest reliability of freesurfer measurements within and between sites: Effects of visual approval process.

    Science.gov (United States)

    Iscan, Zafer; Jin, Tony B; Kendrick, Alexandria; Szeglin, Bryan; Lu, Hanzhang; Trivedi, Madhukar; Fava, Maurizio; McGrath, Patrick J; Weissman, Myrna; Kurian, Benji T; Adams, Phillip; Weyandt, Sarah; Toups, Marisa; Carmody, Thomas; McInnis, Melvin; Cusin, Cristina; Cooper, Crystal; Oquendo, Maria A; Parsey, Ramin V; DeLorenzo, Christine

    2015-09-01

    In the last decade, many studies have used automated processes to analyze magnetic resonance imaging (MRI) data such as cortical thickness, which is one indicator of neuronal health. Due to the convenience of image processing software (e.g., FreeSurfer), standard practice is to rely on automated results without performing visual inspection of intermediate processing. In this work, structural MRIs of 40 healthy controls who were scanned twice were used to determine the test-retest reliability of FreeSurfer-derived cortical measures in four groups of subjects-those 25 that passed visual inspection (approved), those 15 that failed visual inspection (disapproved), a combined group, and a subset of 10 subjects (Travel) whose test and retest scans occurred at different sites. Test-retest correlation (TRC), intraclass correlation coefficient (ICC), and percent difference (PD) were used to measure the reliability in the Destrieux and Desikan-Killiany (DK) atlases. In the approved subjects, reliability of cortical thickness/surface area/volume (DK atlas only) were: TRC (0.82/0.88/0.88), ICC (0.81/0.87/0.88), PD (0.86/1.19/1.39), which represent a significant improvement over these measures when disapproved subjects are included. Travel subjects' results show that cortical thickness reliability is more sensitive to site differences than the cortical surface area and volume. To determine the effect of visual inspection on sample size required for studies of MRI-derived cortical thickness, the number of subjects required to show group differences was calculated. Significant differences observed across imaging sites, between visually approved/disapproved subjects, and across regions with different sizes suggest that these measures should be used with caution. © 2015 Wiley Periodicals, Inc.

  9. Testing a novel method for measuring sleeping metabolic rate in neonates.

    Science.gov (United States)

    Summer, Suzanne S; Pratt, Jesse M; Koch, Elizabeth A; Anderson, Jeffrey B

    2014-07-01

    Sleeping metabolic rate (SMR) is used as a proxy for basal metabolic rate in infants, when measurement while awake is not practical. Measuring SMR via indirect calorimetry (IC) can be useful for assessing feeding adequacy especially in compromised neonates. Standard IC equipment, including a hood placed over the head, is not designed for the smallest of patients. Our aim was to determine whether a nonstandard smaller hood measures SMR in neonates similarly compared with a standard large hood. SMR was measured in healthy neonates (controls) and those born with single-ventricle congenital heart disease (cases). Two measurements were performed: SMR using a standard large hood and SMR using a smaller hood. Time-to-steady state, minute ventilation (V̇E), and fraction of exhaled carbon dioxide (FĒCO2 ; an indicator of data quality) were also measured. Primary outcome was SMR using both hoods. Results are stated as median (interquartile range). Spearman's correlations measured association between the small and large hoods. We studied 9 controls and 7 cases. SMR in controls was not different between the small and large hoods (35.7 [15.14] vs 37.8 [7.41] kcal/kg/d, respectively). In cases, SMR with the small hood was significantly greater than that with the large hood (45.5 [4.63] vs 34.2 [8] kcal/kg/d, P < .02). FĒCO2 was significantly higher with the small hood versus the large hood in both groups, and V̇E was significantly lower with the small hood versus the large hood in controls only. The SMRs with the small and large hoods were significantly correlated in the control group (r = 0.80, P < .01). Time-to-steady state was similar in both groups regardless of hood size. SMR measured with a small hood yields results similar to those measured with a large hood in healthy neonates without affecting testing time or other aspects of the IC procedure. Furthermore, results in compromised infants suggest that a smaller hood may facilitate SMR testing in this population

  10. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  11. Neutron dose rate at the SwissFEL injector test facility: first measurements

    International Nuclear Information System (INIS)

    Hohmann, E.; Frey, N.; Fuchs, A.; Harm, C.; Hoedlmoser, H.; Luescher, R.; Mayer, S.; Morath, O.; Philipp, R.; Rehmann, A.; Schietinger, T.

    2014-01-01

    At the Paul Scherrer Institute, the new SwissFEL Free Electron Laser facility is currently in the design phase. It is foreseen to accelerate electrons up to a maximum energy of 7 GeV with a pulsed time structure. An injector test facility is operated at a maximum energy of 300 MeV and serves as the principal test and demonstration plant for the SwissFEL project. Secondary radiation is created in unavoidable interactions of the primary beam with beamline components. The resulting ambient dose-equivalent rate due to neutrons was measured along the beamline with different commercially available survey instruments. The present study compares the readings of these neutron detectors (one of them is specifically designed for measurements in pulsed fields). The experiments were carried out in both, a normal and a diagnostic mode of operation of the injector. Measurements were taken at the SwissFEL injector test facility using three different types of commercially available survey instruments for normal and diagnostic mode of operation at different positions inside the accelerator vault. During normal operation, the doses indicated by the different instruments agree within the measurement uncertainty except for the beam dump region. There, due to its limited energy range and high sensitivity, the LB6411 shows significantly lower dose values than the other instruments. The photon background in the vault associated with each pulse causes the scintillator used by the LB6419 to saturate. As a result, only the channel using the delayed 12 C(n,p)12-reaction could be used during the measurements. The highest doses per pulse were measured next to the beam dump and the bunch compressor. For the optimisation of the accelerator, luminescent screens can be inserted into the beam path causing a dose distributed over several metres depending on the screen type. The dose arise to 40 % from neutrons with energies of >20 MeV. Although the charge of each pulse were reduced to decrease

  12. Measurement of testicular volume in smaller testes: how accurate is the conventional orchidometer?

    Science.gov (United States)

    Lin, Chih-Chieh; Huang, William J S; Chen, Kuang-Kuo

    2009-01-01

    The aim of this study was to evaluate the accuracy of different methods, including the Seager orchidometer (SO) and ultrasonography (US), for assessing testicular volume of smaller testes (testes volume less than 18 mL). Moreover, the equations used for the calculations--the Hansen formula (length [L] x width [W](2) x 0.52, equation A), the prolate ellipsoid formula (L x W x height [H] x 0.52, equation B), and the Lambert equation (L x W x H x 0.71, equation C)--were also examined and compared with the gold standard testicular volume obtained by water displacement (Archimedes principle). In this study, 30 testes from 15 men, mean age 75.3 (+/-8.3) years, were included. They all had advanced prostate cancer and were admitted for orchiectomy. Before the procedure, all the testes were assessed using SO and US. The dimensions were then input into each equation to obtain the volume estimates. The testicular volume by water displacement was 8.1 +/- 3.5 mL. Correlation coefficients (R(2)) of the 2 different methods (SO, US) to the gold standard were 0.70 and 0.85, respectively. The calculated testicular volumes were 9.2 +/- 3.9 mL (measured by SO, equation A), 11.9 +/- 5.2 mL (measured by SO, equation C), 7.3 +/- 4.2 mL (measured by US, equation A), 6.5 +/- 3.3 mL (measured by US, equation B) and 8.9 +/- 4.5 mL (measured by US, equation C). Only the mean size measured by US and volume calculated with the Hansen equation (equation A) and the mean size measured by US and volume calculated with the Lambert equation (equation C) showed no significant differences when compared with the volumes estimated by water displacement (mean difference 0.81 mL, P = .053, and 0.81 mL, P = .056, respectively). Based on our measurements, we categorized testicular volume by different cutoff values (7.0 mL, 7.5 mL, 8.0 mL, and 8.5 mL) to calculate a new constant for use in the Hansen equation. The new constant was 0.59. We then reexamined the equations using the new 0.59 constant, and found

  13. Testing and Estimating Shape-Constrained Nonparametric Density and Regression in the Presence of Measurement Error

    KAUST Repository

    Carroll, Raymond J.

    2011-03-01

    In many applications we can expect that, or are interested to know if, a density function or a regression curve satisfies some specific shape constraints. For example, when the explanatory variable, X, represents the value taken by a treatment or dosage, the conditional mean of the response, Y , is often anticipated to be a monotone function of X. Indeed, if this regression mean is not monotone (in the appropriate direction) then the medical or commercial value of the treatment is likely to be significantly curtailed, at least for values of X that lie beyond the point at which monotonicity fails. In the case of a density, common shape constraints include log-concavity and unimodality. If we can correctly guess the shape of a curve, then nonparametric estimators can be improved by taking this information into account. Addressing such problems requires a method for testing the hypothesis that the curve of interest satisfies a shape constraint, and, if the conclusion of the test is positive, a technique for estimating the curve subject to the constraint. Nonparametric methodology for solving these problems already exists, but only in cases where the covariates are observed precisely. However in many problems, data can only be observed with measurement errors, and the methods employed in the error-free case typically do not carry over to this error context. In this paper we develop a novel approach to hypothesis testing and function estimation under shape constraints, which is valid in the context of measurement errors. Our method is based on tilting an estimator of the density or the regression mean until it satisfies the shape constraint, and we take as our test statistic the distance through which it is tilted. Bootstrap methods are used to calibrate the test. The constrained curve estimators that we develop are also based on tilting, and in that context our work has points of contact with methodology in the error-free case.

  14. Effective safety measures with tests followed by design correction for aerospace structures

    Science.gov (United States)

    Matsumura, Taiki

    Analytical and computational prediction tools enable us to design aircraft and spacecraft components with high degree of confidence. While the accuracy of such predictions has been improved over the years, uncertainty continues to be added by new materials and new technology introduced in order to improve performance. This requires us to have reality checks, such as tests, in order to make sure that the prediction tools are reliable enough to ensure safety. While tests can reveal unsafe designs and lead to design correction, these tests are very costly. Therefore, it is important to manage such a design-test-correction cycle effectively. In this dissertation, we consider three important test stages in the lifecycle of an aviation system. First, we dealt with characterization tests that reveal failure modes of new materials or new geometrical arrangements. We investigated the challenge associated with getting the best characterization with a limited number of tests. We have found that replicating tests to attenuate the effect of noise in observation is not necessary because some surrogate models can serve as a noise filter without having replicated data. Instead, we should focus on exploring the design space with different structural configurations in order to discover unknown failure modes. Next, we examined post-design tests for design acceptance followed by possible redesign. We looked at the question of how to balance the desire for better performance achieved by redesign against the cost of redesign. We proposed a design optimization framework that provides tradeoff information between the expected performance improvement by redesign and the probability of redesign, equivalent to the cost of redesign. We also demonstrated that the proposed method can reduce the performance loss due to a conservative reliability estimate. The ultimate test, finally, is whether the structures do not fail in flight. Once an accident occurs, an accident investigation takes place

  15. Using Tests Designed to Measure Individual Sensorimotor Subsystem Perfomance to Predict Locomotor Adaptability

    Science.gov (United States)

    Peters, B. T.; Caldwell, E. E.; Batson, C. D.; Guined, J. R.; DeDios, Y. E.; Stepanyan, V.; Gadd, N. E.; Szecsy, D. L.; Mulavara, A. P.; Seidler, R. D.; hide

    2014-01-01

    Astronauts experience sensorimotor disturbances during the initial exposure to microgravity and during the readapation phase following a return to a gravitational environment. These alterations may lead to disruption in the ability to perform mission critical functions during and after these gravitational transitions. Astronauts show significant inter-subject variation in adaptive capability following gravitational transitions. The way each individual's brain synthesizes the available visual, vestibular and somatosensory information is likely the basis for much of the variation. Identifying the presence of biases in each person's use of information available from these sensorimotor subsystems and relating it to their ability to adapt to a novel locomotor task will allow us to customize a training program designed to enhance sensorimotor adaptability. Eight tests are being used to measure sensorimotor subsystem performance. Three of these use measures of body sway to characterize balance during varying sensorimotor challenges. The effect of vision is assessed by repeating conditions with eyes open and eyes closed. Standing on foam, or on a support surface that pitches to maintain a constant ankle angle provide somatosensory challenges. Information from the vestibular system is isolated when vision is removed and the support surface is compromised, and it is challenged when the tasks are done while the head is in motion. The integration and dominance of visual information is assessed in three additional tests. The Rod & Frame Test measures the degree to which a subject's perception of the visual vertical is affected by the orientation of a tilted frame in the periphery. Locomotor visual dependence is determined by assessing how much an oscillating virtual visual world affects a treadmill-walking subject. In the third of the visual manipulation tests, subjects walk an obstacle course while wearing up-down reversing prisms. The two remaining tests include direct

  16. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and

  17. Complexity-Measure-Based Sequential Hypothesis Testing for Real-Time Detection of Lethal Cardiac Arrhythmias

    Directory of Open Access Journals (Sweden)

    Chen Szi-Wen

    2007-01-01

    Full Text Available A novel approach that employs a complexity-based sequential hypothesis testing (SHT technique for real-time detection of ventricular fibrillation (VF and ventricular tachycardia (VT is presented. A dataset consisting of a number of VF and VT electrocardiogram (ECG recordings drawn from the MIT-BIH database was adopted for such an analysis. It was split into two smaller datasets for algorithm training and testing, respectively. Each ECG recording was measured in a 10-second interval. For each recording, a number of overlapping windowed ECG data segments were obtained by shifting a 5-second window by a step of 1 second. During the windowing process, the complexity measure (CM value was calculated for each windowed segment and the task of pattern recognition was then sequentially performed by the SHT procedure. A preliminary test conducted using the database produced optimal overall predictive accuracy of . The algorithm was also implemented on a commercial embedded DSP controller, permitting a hardware realization of real-time ventricular arrhythmia detection.

  18. A Protocol of Manual Tests to Measure Sensation and Pain in Humans.

    Science.gov (United States)

    Kostek, Matthew; Polaski, Anna; Kolber, Benedict; Ramsey, Austin; Kranjec, Alexander; Szucs, Kimberly

    2016-12-19

    Numerous qualitative and quantitative techniques can be used to test sensory nerves and pain in both research and clinical settings. The current study demonstrates a quantitative sensory testing protocol using techniques to measure tactile sensation and pain threshold for pressure and heat using portable and easily accessed equipment. These techniques and equipment are ideal for new laboratories and clinics where cost is a concern or a limiting factor. We demonstrate measurement techniques for the following: cutaneous mechanical sensitivity on the arms and legs (von-Frey filaments), radiant and contact heat sensitivity (with both threshold and qualitative assessments using the Visual Analog Scale (VAS)), and mechanical pressure sensitivity (algometer, with both threshold and the VAS). The techniques and equipment described and demonstrated here can be easily purchased, stored, and transported by most clinics and research laboratories around the world. A limitation of this approach is a lack of automation or computer control. Thus, these processes can be more labor intensive in terms of personnel training and data recording than the more sophisticated equipment. We provide a set of reliability data for the demonstrated techniques. From our description, a new laboratory should be able to set up and run these tests and to develop their own internal reliability data.

  19. Development and testing of technical measures for the abatement of PM10 emissions from poultry housings

    Energy Technology Data Exchange (ETDEWEB)

    Ogink, N.W.M.; Aarnink, A.J.A.; Mosquera, J.; Winkel, A. [Wageningen UR Livestock Research, Wageningen (Netherlands)

    2010-07-01

    In order to comply with the European Union's ambient air quality standards, the Netherlands must reduce emissions of PM10. As a contributor to PM10, the poultry industry must implement mitigation measures before 2012. An extensive research and development program was launched in 2008 to provide abatement technology for broiler and layer houses. This paper presented results from studies carried out in 2008 and 2009 by Wageningen UR Livestock Research. The supply industry and poultry farmers participated in the study in which different methods and approaches were examined, including bedding material, light schedules, oil spraying systems, ionization systems, water scrubbers, combined scrubbers, electrostatic filters, and dry filters. Most methods were first tested and optimized in small units at an experimental poultry facility Lelystad. Several methods were validated in a next step on poultry farms, where PM10 emissions were measured to establish official emission factors. The oil spraying system and ionization system were tested in broiler houses and are nearing implementation. Reductions in PM10 emissions by different methods ranged from no effect to levels of 60 per cent. An outlook on adequate dust abatement measures for poultry housings was also provided.

  20. Testing accuracy of long-range ultrasonic sensors for olive tree canopy measurements.

    Science.gov (United States)

    Gamarra-Diezma, Juan Luis; Miranda-Fuentes, Antonio; Llorens, Jordi; Cuenca, Andrés; Blanco-Roldán, Gregorio L; Rodríguez-Lizana, Antonio

    2015-01-28

    Ultrasonic sensors are often used to adjust spray volume by allowing the calculation of the crown volume of tree crops. The special conditions of the olive tree require the use of long-range sensors, which are less accurate and faster than the most commonly used sensors. The main objectives of the study were to determine the suitability of the sensor in terms of sound cone determination, angle errors, crosstalk errors and field measurements. Different laboratory tests were performed to check the suitability of a commercial long-range ultrasonic sensor, as were the experimental determination of the sound cone diameter at several distances for several target materials, the determination of the influence of the angle of incidence of the sound wave on the target and distance on the accuracy of measurements for several materials and the determination of the importance of the errors due to interference between sensors for different sensor spacings and distances for two different materials. Furthermore, sensor accuracy was tested under real field conditions. The results show that the studied sensor is appropriate for olive trees because the sound cone is narrower for an olive tree than for the other studied materials, the olive tree canopy does not have a large influence on the sensor accuracy with respect to distance and angle, the interference errors are insignificant for high sensor spacings and the sensor's field distance measurements were deemed sufficiently accurate.