WorldWideScience

Sample records for single-shot electron bunch

  1. Real-time single-shot electron bunch length measurements

    CERN Document Server

    Wilke, I; Gillespie, W A; Berden, G; Knippels, G M H; Meer, A F G

    2002-01-01

    Linear accelerators employed as drivers for X-ray free electron lasers (FELs) require relativistic electron bunch with sub-picosecond bunch length. Precise bunch length measurements are important for the tuning and operation of the FELs. Previously, we have demonstrated that electro-optic detection is a powerful technique for sub-picosecond electron bunch length measurements. In those experiments, the measured bunch length was the average of all electron bunches within a macropulse. Here, for the first time, we present the measurement of the length of individual electron bunches using a development of our previous technique. In this experiment, the longitudinal electron bunch shape is encoded electro-optically on to the frequency spectrum of a chirped laser pulse. Subsequently, the laser pulse is dispersed by a grating and the spectrum is imaged with a CCD camera. Single bunch measurements are achieved by using a nanosecond gated camera, and synchronizing the gate with both the electron bunch and the laser pu...

  2. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  3. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  4. Real-Time, Single-Shot Temporal Measurements of Short Electron Bunches, Terahertz CSR and FEL Radiation

    CERN Document Server

    Berden, G; Van der Meer, A F G

    2005-01-01

    Electro-optic detection of the Coulomb field of electron bunches is a promising technique for single-shot measurements of the bunch length and shape in the sub-picosecond time domain. This technique has been applied to the measurement of 50 MeV electron bunches in the FELIX free electron laser, showing the longitudinal profile of single bunches of around 650 fs FWHM [Phys. Rev. Lett. 93, 114802 (2004)]. The method is non-destructive and real-time, and therefore ideal for online monitoring of the longitudinal shape of single electron bunches. At FELIX we have used it for real-time optimization of sub-picosecond electron bunches. Electro-optic detection has also been used to measure the electric field profiles of far-infrared (or terahertz) optical pulses generated by the relativistic electrons. We have characterised the far-infrared output of the free electron laser, and more recently, we have measured the temporal profile of terahertz optical pulses generated at one of the bending magnets.

  5. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  6. A multi-channel THz and infrared spectrometer for femtosecond electron bunch diagnostics by single-shot spectroscopy of coherent radiation

    International Nuclear Information System (INIS)

    Wesch, Stephan; Schmidt, Bernhard; Behrens, Christopher; Delsim-Hashemi, Hossein; Schmueser, Peter

    2011-08-01

    The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5-44 μm) or in long wavelength mode (45-430 μm). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching e ects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation. (orig.)

  7. A multi-channel THz and infrared spectrometer for femtosecond electron bunch diagnostics by single-shot spectroscopy of coherent radiation

    Energy Technology Data Exchange (ETDEWEB)

    Wesch, Stephan; Schmidt, Bernhard; Behrens, Christopher; Delsim-Hashemi, Hossein; Schmueser, Peter

    2011-08-15

    The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5-44 {mu}m) or in long wavelength mode (45-430 {mu}m). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching e ects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation. (orig.)

  8. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  9. A Novel Diagnostics of Ultrashort Electron Bunches Based on Detection of Coherent Radiation from Bunched Electron Beam in an Undulator

    CERN Document Server

    Saldin, Evgeny L; Yurkov, Mikhail V

    2004-01-01

    We propose a new method for measurements of the longitudinal profile of 100 femtosecond electron bunches for X-ray Free Electron Lasers (XFELs). The method is based on detection of coherent undulator radiation produced by modulated electron beam. Seed optical quantum laser is used to produce exact optical replica of ultrashort electron bunches. The replica is generated in apparatus which consists of an input undulator (energy modulator), and output undulator (radiator) separated by a dispersion section. The radiation in the output undulator is excited by the electron bunch modulated at the optical wavelength and rapidly reaches a hundred-MW-level power. We then use the now-standard method of ultrashort laser pulse-shape measurement, a tandem combination of autocorrelator and spectrum (FROG -- frequency resolved optical gating) providing real-time single-shot measurements of the electron bunch structure. The big advantage of proposed technique is that it can be used to determine the slice energy spread and emi...

  10. Longitudinal Diagnostics for Short Electron Beam Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Loos, H.; /SLAC

    2010-06-11

    the beam mapped onto (optical replicator). The operational needs for bunch length measurements to have fast acquisitions, to be used in feedback systems, to distinguish pulse to pulse changes and to be nondestructive or parasitically have resulted into developing many of the diagnostics into single-shot techniques and in the following the main discussion will emphasize them.

  11. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  12. Measurement of Sub-Picosecond Electron Bunches via Electro-Optic Sampling of Coherent Transition Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Timothy John [Northern Illinois U.

    2012-01-01

    Future collider applications as well as present high-gradient laser plasma wakefield accelerators and free-electron lasers operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. We present results on the single-shot electro-optic spectral decoding of coherent transition radiation from bunches generated at the Fermilab A0 photoinjector laboratory. A longitudinal double-pulse modulation of the electron beam is also realized by transverse beam masking followed by a transverse-to-longitudinal phase-space exchange beamline. Live profile tuning is demonstrated by upstream beam focusing in conjunction with downstream monitoring of single-shot electro-optic spectral decoding of the coherent transition radiation.

  13. Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Mo, M. Z., E-mail: mmo09@slac.stanford.edu; Shen, X.; Chen, Z.; Li, R. K.; Dunning, M.; Zheng, Q.; Weathersby, S. P.; Reid, A. H.; Coffee, R.; Makasyuk, I.; Edstrom, S.; McCormick, D.; Jobe, K.; Hast, C.; Glenzer, S. H.; Wang, X. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Sokolowski-Tinten, K. [Faculty of Physics and Centre for Nanointegration Duisburg-Essen, University of Duisburg-Essen, Lotharstrasse 1, D-47048 Duisburg (Germany)

    2016-11-15

    We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

  14. Single-shot spectro-temporal characterization of XUV pulses from a seeded free-electron laser

    Science.gov (United States)

    de Ninno, Giovanni; Gauthier, David; Mahieu, Benoît; Ribič, Primož Rebernik; Allaria, Enrico; Cinquegrana, Paolo; Danailov, Miltcho Bojanov; Demidovich, Alexander; Ferrari, Eugenio; Giannessi, Luca; Penco, Giuseppe; Sigalotti, Paolo; Stupar, Matija

    2015-08-01

    Intense ultrashort X-ray pulses produced by modern free-electron lasers (FELs) allow one to probe biological systems, inorganic materials and molecular reaction dynamics with nanoscale spatial and femtoscale temporal resolution. These experiments require the knowledge, and possibly the control, of the spectro-temporal content of individual pulses. FELs relying on seeding have the potential to produce spatially and temporally fully coherent pulses. Here we propose and implement an interferometric method, which allows us to carry out the first complete single-shot spectro-temporal characterization of the pulses, generated by an FEL in the extreme ultraviolet spectral range. Moreover, we provide the first direct evidence of the temporal coherence of a seeded FEL working in the extreme ultraviolet spectral range and show the way to control the light generation process to produce Fourier-limited pulses. Experiments are carried out at the FERMI FEL in Trieste.

  15. Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Masahiro, Kato; Norio, Saito; Yuichiro, Morishita; Takahiro, Tanaka [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba (Japan); Masahiro, Kato; Norio, Saito; Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Richter, M.; Takahiro, Tanaka; Mitsuru, Nagasono; Makina, Yabashi; Kensuke, Tono; Tadashi, Togashi; Tetsuya, Ishikawa [RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo (Japan); Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Jastrow, U. [Deutsches Elektronen-Synchrotron, DESY, Hamburg (Germany); Sorokin, A.A. [Ioffe Physico-Technical Institute, Polytekhnicheskaya 26, St Petersburg (Russian Federation); Richter, M.; Kroth, U.; Schoppe, H. [Physikalisch-Technische Bundesanstalt, PTB, Berlin (Germany); Tadashi, Togashi; Hiroaki, Kimura; Haruhiko, Ohashi [Japan Synchrotron Radiation Research Institute, Sayo, Hyogo (Japan)

    2010-10-15

    The absolute single-shot pulse energy of the SPring 8 extreme ultraviolet (EUV) free electron laser (FEL) was measured using a cryogenic radiometer with a relative standard uncertainty of 3%. The temperature change of the cavity in the cryogenic radiometer caused by an incident FEL pulse was determined using a lock-in amplifier and an ac Wheatstone bridge. The measured pulse energies were compared with a gas-monitor detector developed by Physikalisch-Technische Bundesanstalt/Deutsches Elektronen-Synchrotron/Ioffe Physico-Technical Institute (Ioffe) at a wavelength of 51.3 nm at the SPring-8 EUV-FEL in a shot-to-shot mode. The pulse energies measured using the two detectors agree within 2.0%. (authors)

  16. Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

    Directory of Open Access Journals (Sweden)

    Taito Osaka

    2017-11-01

    Full Text Available Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

  17. FLASH free-electron laser single-shot temporal diagnostic: terahertz-field-driven streaking.

    Science.gov (United States)

    Ivanov, Rosen; Liu, Jia; Brenner, Günter; Brachmanski, Maciej; Düsterer, Stefan

    2018-01-01

    The commissioning of a terahertz-field-driven streak camera installed at the free-electron laser (FEL) FLASH at DESY in Hamburg, being able to deliver photon pulse duration as well as arrival time information with ∼10 fs resolution for each single XUV FEL pulse, is reported. Pulse durations between 300 fs and terahertz-streaking setup was operated simultaneously to an alternative method to determine the FEL pulse duration based on spectral analysis. FLASH pulse duration derived from simple spectral analysis is in good agreement with that from terahertz-streaking measurement.

  18. Single-shot beam-position monitor for x-ray free electron laser

    Science.gov (United States)

    Tono, Kensuke; Kudo, Togo; Yabashi, Makina; Tachibana, Takeshi; Feng, Yiping; Fritz, David; Hastings, Jerome; Ishikawa, Tetsuya

    2011-02-01

    We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 μm by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL.

  19. Method for the determination of the three-dimensional structure of ultrashort relativistic electron bunches

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca; Ilinski, Petr; Saldin, Evgeni; Schneidmiller, Evgeni; Yurkov, Mikhail

    2009-05-15

    We describe a novel technique to characterize ultrashort electron bunches in Xray Free-Electron Lasers. Namely, we propose to use coherent Optical Transition Radiation to measure three-dimensional (3D) electron density distributions. Our method relies on the combination of two known diagnostics setups, an Optical Replica Synthesizer (ORS) and an Optical Transition Radiation (OTR) imager. Electron bunches are modulated at optical wavelengths in the ORS setup.When these electron bunches pass through a metal foil target, coherent radiation pulses of tens MW power are generated. It is thereafter possible to exploit advantages of coherent imaging techniques, such as direct imaging, diffractive imaging, Fourier holography and their combinations. The proposed method opens up the possibility of real-time, wavelength-limited, single-shot 3D imaging of an ultrashort electron bunch. (orig.)

  20. Energy spread of ultracold electron bunches extracted from a laser cooled gas

    Science.gov (United States)

    Franssen, J. G. H.; Kromwijk, J. M.; Vredenbregt, E. J. D.; Luiten, O. J.

    2018-02-01

    Ultrashort and ultracold electron bunches created by near-threshold femtosecond photoionization of a laser cooled gas hold great promise for single-shot ultrafast diffraction experiments. In previous publications the transverse beam quality and the bunch length have been determined. Here the longitudinal energy spread of the generated bunches is measured for the first time, using a specially developed Wien filter. The Wien filter has been calibrated by determining the average deflection of the electron bunch as a function of magnetic field. The measured relative energy spread \\tfrac{{σ }U}{U}=0.64+/- 0.09 % agrees well with the theoretical model which states that it is governed by the width of the ionization laser and the acceleration length.

  1. Femtosecond electron bunches, source and characterization

    International Nuclear Information System (INIS)

    Thongbai, C.; Kusoljariyakul, K.; Rimjaem, S.; Rhodes, M.W.; Saisut, J.; Thamboon, P.; Wichaisirimongkol, P.; Vilaithong, T.

    2008-01-01

    A femtosecond electron source has been developed at the Fast Neutron Research Facility (FNRF), Chiang Mai University, Thailand. So far, it has produced electron bunches as short as σ z ∼180 fs with (1-6)x10 8 electrons per microbunch. The system consists of an RF-gun with a thermionic cathode, an alpha-magnet as a magnetic bunch compressor, and a linear accelerator as a post acceleration section. Coherent transition radiation emitted at wavelengths equal to and longer than the bunch length is used in a Michelson interferometer to determine the bunch length by autocorrelation technique. The experimental setup and results of the bunch length measurement are described

  2. Wavefront Analysis of Nonlinear Self-Amplified Spontaneous-Emission Free-Electron Laser Harmonics in the Single-Shot Regime

    Energy Technology Data Exchange (ETDEWEB)

    Bachelard, R.; Chubar, O.; Mercere, P.; Idir, M.; Couprie, M.E.; Lambert, G.; Zeitoun, Ph.; Kimura, H.; Ohashi, H.; Higashiya, A.; Yabashi, M.; Nagasono, M.; Hara, T. and Ishikawa, T.

    2011-06-08

    The single-shot spatial characteristics of the vacuum ultraviolet self-amplified spontaneous emission of a free electron laser (FEL) is measured at different stages of amplification up to saturation with a Hartmann wavefront sensor. We show that the fundamental radiation at 61.5 nm tends towards a single-mode behavior as getting closer to saturation. The measurements are found in good agreement with simulations and theory. A near diffraction limited wavefront was measured. The analysis of Fresnel diffraction through the Hartmann wavefront sensor hole array also provides some further insight for the evaluation of the FEL transverse coherence, of high importance for various applications.

  3. An Optical Streaking Method for Measuring Femtosecond Electron Bunches

    International Nuclear Information System (INIS)

    Ding, Yuantao

    2011-01-01

    The measurement of the ultra-short electron bunch length on the femtosecond time scale constitutes a very challenging problem. In the x-ray free electron laser facilities such as the Linac Coherent Light Source, generation of a sub-ten femtoseconds electron beam with 20pC charge is possible, but direct measurements are very difficult due to the resolution limit of the present diagnostics. We propose a new method here based on the measurement of the electron beam energy modulation induced from laser-electron interaction in a short wiggler. A typical optical streaking method requires a laser wavelength much longer than the electron bunch length. In this paper a laser with its wavelength shorter than the electron bunch length has been adopted, while the slope on the laser intensity envelope is used to distinguish the different periods. With this technique it is possible to reconstruct the bunch longitudinal profile from a single shot measurement. Generation of ultrashort x-ray pulses at femtoseconds (fs) scale is of great interest within synchrotron radiation and free electron laser (FEL) user community. One of the simple methods is to operate the FEL facility at low charge. At the Linac Coherent Light Source (LCLS), we have demonstrated the capability of generating ultrashort electron-beam (e-beam) with a duration of less than 10 fs fwhm using 20 pC charge. The x-ray pulses have been delivered to the x-ray users with a similar or even shorter pulse duration. However, The measurement of such short electron or x-ray pulse length at the fs time-scale constitutes a challenging problem. A standard method using an S-band radio-frequency (rf) transverse deflector has been established at LCLS, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as 25 fs fwhm. With this device, the electrons are transversely deflected by the high-frequency time-variation of the deflecting fields. Increasing the deflecting voltage and rf frequency

  4. A robust fibre laser system for electro-optic electron bunch profile measurements at FLASH

    International Nuclear Information System (INIS)

    Wissmann, Laurens-Georg

    2012-08-01

    For the electro-optic measurement of electron bunch profiles at FLASH a robust ytterbium doped fibre laser (YDFL) system has been developed consisting of a laser oscillator and a two-staged amplifier. The oscillator is designed to meet the specifications of high reliability and low noise operation. The amplifier makes use of tailored nonlinearity to enhance the spectral bandwidth of the output laser pulses. Active repetition rate control enables sub-picosecond synchronisation of the laser to the accelerator reference RF. Using a two-stage gating scheme the output pulse train repetition rate is adopted to the accelerator repetition rate. An experimental site used for electro-optic electron bunch diagnostics has been redesigned to support single-shot bunch profile measurements based on spectral decoding. An existing bunch profile monitor with a similar laser system was upgraded and electro-optic bunch profile measurements were conducted, allowing for a comparison with measurements done with other longitudinal electron bunch diagnostics and with former measurements.

  5. A robust fibre laser system for electro-optic electron bunch profile measurements at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Wissmann, Laurens-Georg

    2012-08-15

    For the electro-optic measurement of electron bunch profiles at FLASH a robust ytterbium doped fibre laser (YDFL) system has been developed consisting of a laser oscillator and a two-staged amplifier. The oscillator is designed to meet the specifications of high reliability and low noise operation. The amplifier makes use of tailored nonlinearity to enhance the spectral bandwidth of the output laser pulses. Active repetition rate control enables sub-picosecond synchronisation of the laser to the accelerator reference RF. Using a two-stage gating scheme the output pulse train repetition rate is adopted to the accelerator repetition rate. An experimental site used for electro-optic electron bunch diagnostics has been redesigned to support single-shot bunch profile measurements based on spectral decoding. An existing bunch profile monitor with a similar laser system was upgraded and electro-optic bunch profile measurements were conducted, allowing for a comparison with measurements done with other longitudinal electron bunch diagnostics and with former measurements.

  6. Measurement of the X-ray Spectrum of a Free Electron Laser with a Wide-Range High-Resolution Single-Shot Spectrometer

    Directory of Open Access Journals (Sweden)

    Yuichi Inubushi

    2017-06-01

    Full Text Available We developed a single-shot X-ray spectrometer for wide-range high-resolution measurements of Self-Amplified Spontaneous Emission (SASE X-ray Free Electron Laser (XFEL pulses. The spectrometer consists of a multi-layer elliptical mirror for producing a large divergence of 22 mrad around 9070 eV and a silicon (553 analyzer crystal. We achieved a wide energy range of 55 eV with a fine spectral resolution of 80 meV, which enabled the observation of a whole SASE-XFEL spectrum with fully-resolved spike structures. We found that a SASE-XFEL pulse has around 60 longitudinal modes with a pulse duration of 7.7 ± 1.1 fs.

  7. Electron bunch diagnostics for laser-plasma accelerators, from THz to X-rays

    International Nuclear Information System (INIS)

    Plateau, G.

    2011-10-01

    This thesis presents a series of single-shot non-intrusive diagnostics of key attributes of electron bunches produced by a laser-plasma accelerator (LPA). Three injection mechanisms of the LPA are characterized: channeled and self-guided self-injection, plasma down-ramp injection, and two-beam colliding pulse injection. New diagnostic techniques are successfully demonstrated: up to 8 times higher sensitivity wavefront sensor-based plasma density measurements, strong spatio-temporal coupling of the focused THz pulse is demonstrated using the temporal electric-field cross-correlation (TEX) of a long chirped probe with a short probe and confirms the two-component structure of the bunch observed by electron spectrometry, and normalized transverse emittances as low as 0.1 mm mrad are demonstrated for 0.5 GeV-class beams produced in a capillary-guided LPA by characterizing the betatron radiation emitted by the electrons inside the plasma using a new single-shot X-ray spectroscopy technique. (author)

  8. Evolution of dense spatially modulated electron bunches

    Science.gov (United States)

    Balal, N.; Bratman, V. L.; Friedman, A.

    2018-03-01

    An analytical theory describing the dynamics of relativistic moving 1D electron pulses (layers) with the density modulation affected by a space charge has been revised and generalized for its application to the formation of dense picosecond bunches from linear accelerators with laser-driven photo injectors, and its good agreement with General Particle Tracer simulations has been demonstrated. Evolution of quasi-one-dimensional bunches (disks), for which the derived formulas predict longitudinal expansion, is compared with that for thin and long electron cylinders (threads), for which the excitation of non-linear waves with density spikes was found earlier by Musumeci et al. [Phys. Rev. Lett. 106(18), 184801 (2011)] and Musumeci et al. [Phys. Rev. Spec. Top. -Accel. Beams 16(10), 100701 (2013)]. Both types of bunches can be used for efficiency enhancement of THz sources based on the Doppler frequency up-shifted coherent spontaneous radiation of electrons. Despite the strong Coulomb repulsion, the periodicity of a preliminary modulation in dense 1D layers persists during their expansion in the most interesting case of a relatively small change in particle energy. However, the period of modulation increases and its amplitude decreases in time. In the case of a large change in electron energy, the uniformity of periodicity is broken due to different relativistic changes in longitudinal scales along the bunch: the "period" of modulation decreases and its amplitude increases from the rear to the front boundary. Nevertheless, the use of relatively long electron bunches with a proper preliminary spatial modulation of density can provide a significantly higher power and a narrower spectrum of coherent spontaneous radiation of dense bunches than in the case of initially short single bunches with the same charge.

  9. ELECTRON BUNCH CHARACTERIZATION WITH SUBPICOSECOND RESOLUTION USING ELECTRO-OPTIC TECHNIQUE

    International Nuclear Information System (INIS)

    SEMERTZIDIS, Y.K.; CASTILLO, V.; LARSEN, R.; LAZARUS, D.M.; NIKAS, D.; OZBEN, C.; SRINIVASAN-RAO, T.; STILLMAN, A.; TSANG, T.; KOWALSKI, L.

    2001-01-01

    In the past decade, the bunch lengths of electrons in accelerators have decreased dramatically and are in the range off a few millimeters. Measurement of the length as well as the longitudinal profile of these short bunches have been a topic of research in a number of institutions. One of the techniques uses the electric field induced by the passage of electrons in the vicinity of a birefringent crystal to change its optical characteristics. Well-established electro-optic techniques can then be used to measure the temporal characteristics of the electron bunch. The inherent fast response of the crystal facilitates the measurement to femtosecond time resolution. However, the resolution in experiments so far has been limited to 70 ps, by the bandwidth of the detection equipment. Use of a streak camera can improve this resolution to a few picoseconds. In this paper we present a novel, non-invasive, single-shot approach to improve the resolution to tens of femtoseconds so that sub mm bunch length can be measured

  10. Femtosecond single electron bunch generation by rotating longitudinal bunch phase space in magnetic field

    International Nuclear Information System (INIS)

    Yang, J.; Kondoh, T.; Kan, K.; Kozawa, T.; Yoshida, Y.; Tagawa, S.

    2006-01-01

    A femtosecond (fs) electron bunching was observed in a photoinjector with a magnetic compressor by rotating the bunch in longitudinal phase space. The bunch length was obtained by measuring Cherenkov radiation of the electron beam with a femtosecond streak camera technique. A single electron bunch with rms bunch length of 98 fs was observed for a 32 MeV electron beam at a charge of 0.17 nC. The relative energy spread and the normalized transverse emittance of the electron beam were 0.2% and 3.8 mm-mrad, respectively. The effect of space charge on the bunch compression was investigated experimentally for charges from 0.17 to 1.25 nC. The dependences of the relative energy spread and the normalized beam transverse emittance on the bunch charge were measured

  11. Theory of coherent transition radiation generated by ellipsoidal electron bunches

    Directory of Open Access Journals (Sweden)

    W. P. E. M. Op ’t Root

    2007-01-01

    Full Text Available We present the theory of coherent transition radiation (CTR generated by ellipsoidal electron bunches. We calculate analytical expressions for the electric field spectrum, the power spectrum, and the temporal electric field of CTR, generated by cylindrically symmetric ellipsoidal electron bunches with hard and soft edges. This theory is relevant for diagnostics of ellipsoidal electron bunches. Realization of such bunches would solve the problem of space-charge induced emittance degradation.

  12. Terahertz radiation as a bunch diagnostic for laser-wakefield-accelerated electron bunches

    Energy Technology Data Exchange (ETDEWEB)

    van Tilborg, Jeroen; Schroeder, Carl; Filip, Catalin; Toth, Csaba; Geddes, Cameron; Fubiani, Gwenael; Esarey, Eric; Leemans, Wim

    2011-06-17

    Experimental results are reported from two measurement techniques (semiconductor switching and electro-optic sampling) that allow temporal characterization of electron bunches produced by a laser-driven plasma-based accelerator. As femtosecond electron bunches exit the plasma-vacuum interface, coherent transition radiation (at THz frequencies) is emitted. Measuring the properties of this radiation allows characterization of the electron bunches. Theoretical work on the emission mechanism is presented, including a model that calculates the THz wave form from a given bunch profile. It is found that the spectrum of the THz pulse is coherent up to the 200 {micro}m thick crystal (ZnTe) detection limit of 4 THz, which corresponds to the production of sub-50 fs (rms) electron bunch structure. The measurements demonstrate both the shot-to-shot stability of bunch parameters that are critical to THz emission (such as total charge and bunch length), as well as femtosecond synchronization among bunch, THz pulse, and laser beam.

  13. Femtosecond electron-bunch dynamics in laser wakefields and vacuum

    Directory of Open Access Journals (Sweden)

    A. G. Khachatryan

    2007-12-01

    Full Text Available Recent advances in laser wakefield acceleration demonstrated the generation of extremely short (with a duration of a few femtoseconds relativistic electron bunches with relatively low (of the order of couple of percent energy spread. In this article we study the dynamics of such bunches in drift space (vacuum and in channel-guided laser wakefields. Analytical solutions were found for the transverse coordinate of an electron and for the bunch envelope in the wakefield in the case of arbitrary change in the energy. Our results show strong bunch dynamics already on a millimeter scale propagation distance both in plasma and in vacuum. When the bunch propagates in vacuum, its transverse sizes grow considerably; the same is observed for the normalized bunch emittance that worsens the focusability of the bunch. A scheme of two-stage laser wakefield accelerator with small drift space between the stages is proposed. It is found that fast longitudinal betatron phase mixing occurs in a femtosecond bunch when it propagates along the wakefield axis. When bunch propagates off axis, strong bunch decoherence and fast emittance degradation due to the finite bunch length was observed.

  14. Electron Bunch Length Diagnostic With Coherent Smith-Purcell Radiation

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1997-01-01

    The authors have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with a period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. The authors show that the new technique is also scaleable to femtosecond regime

  15. Longitudinal Electron Bunch Diagnostics Using Coherent Transition Radiation

    CERN Document Server

    Mihalcea, Daniel; Happek, Uwe; Regis-Guy Piot, Philippe

    2005-01-01

    The longitudinal charge distribution of electron bunches in the Fermilab A0 photo-injector was determined by using the coherent transition radiation produced by electrons passing through a thin metallic foil. The auto-correlation of the transition radiation signal was measured with a Michelson type interferometer. The response function of the interferometer was determined from measured and simulated power spectra for low electron bunch charge and maximum longitudinal compression. Kramers-Kroning technique was used to determine longitudinal charge distribution. Measurements were performed for electron bunch lengths in the range from 0.3 to 2 ps (rms).

  16. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  17. Instability during bunch shortening of an electron-cooled beam

    Directory of Open Access Journals (Sweden)

    M. Takanaka

    2003-10-01

    Full Text Available Bunch shortening causes an electron-cooled beam to be space charge dominated at low energies. Instability during the bunch shortening has been studied using a particle-tracking program where the 3D space-charge field due to the beam is calculated with a simplifying model.

  18. Femtosecond electron-bunch dynamics in laser wakefields and vacuum

    NARCIS (Netherlands)

    Khachatryan, A.G.; Irman, A.; van Goor, F.A.; Boller, Klaus J.

    2007-01-01

    Recent advances in laser wakefield acceleration demonstrated the generation of extremely short (with a duration of a few femtoseconds) relativistic electron bunches with relatively low (of the order of couple of percent) energy spread. In this article we study the dynamics of such bunches in drift

  19. Real-time monitoring of longitudinal electron bunch parameters by intensity-integrated and spectroscopic measurements of single coherent THz pulses

    International Nuclear Information System (INIS)

    Wesch, Stephan

    2012-12-01

    High-gain free-electron lasers (FELs) generate intense and monochromatic photon pulses with few tens of femtosecond duration. For this purpose, electron beams are accelerated to relativistic energies and shrunk longitudinally down to micrometer size.The diagnosis of theses compressed electron bunches is a challenge especially for MHz bunch repetition rates as provided by the FEL FLASH in Hamburg. In this thesis, coherently emitted THz radiation of single electron bunches were investigated, on which the longitudinal structure is imprinted. Two instruments were used: First, the FLASH bunch compression monitors, relying on the integrated intensity measurement of diffraction radiation, were modified to determine the overall length of every bunch behind the two bunch compressors (BC). A model was developed showing that their response is independent of the exact bunch shape for lengths below 200 μm (rms). This could experimentally be verified in the range between 50 and 190 μm within 7% accuracy for themonitor behind the last BC by comparison with measurements with the transverse deflecting structure (TDS). Second, a single-shot spectrometer with five staged reflective blazed gratings has been designed, build and commissioned. With its two grating sets, the wavelength ranges from 5.5 to 44 μm and 45 to 440 μm can be simultaneously detected by 118 fast pyroelectric elements. Measurements based on transition radiation spectra were compared with profiles recorded by the TDS.The shape of the spectra as well as the reconstructed temporal profiles (using the Kramers-Kronig relation for phase retrieval) are in excellent agreement. For bunches with a charge of 50 pC, bunch lengths down to 5 μm (fhwm) could be detected.

  20. Electron bunch length measurement at the Vanderbilt FEL

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, C.A.; Mendenhall, M. [Vanderbilt Free-Electron-Laser Center, Nashville, TN (United States)] [and others

    1995-12-31

    During the past few years, a number of experiments have been performed to demonstrate the possibility to extract the longitudinal charge distribution from spectroscopic measurements of the coherent far-infrared radiation emitted as transition radiation or synchrotron radiation. Coherent emission occurs in a spectral region where the wavelength is comparable to or longer than the bunch length, leading to an enhancement of the radiation intensity that is on the order of the number of particles per bunch, as compared to incoherent radiation. This technique is particularly useful in the region of mm and sub-mm bunch lengths, a range where streak-cameras cannot be used for beam diagnostics due to their limited time resolution. Here we report on experiments that go beyond the proof of principle of this technique by applying it to the study and optimization of FEL performance. We investigated the longitudinal bunch length of the Vanderbilt FEL by analyzing the spectrum of coherent transition radiation emitted by the electron bunches. By monitoring the bunch length while applying a bunch-compression technique, the amount of the compression could be easily observed. This enabled us to perform a systematic study of the FEL performance, especially gain and optical pulse width, as a function of the longitudinal electron distribution in the bunch. The results of this study will be presented and discussed.

  1. Developing electron beam bunching technology for improving light sources

    International Nuclear Information System (INIS)

    Carlsten, B.E.; Chan, K.C.D.; Feldman, D.W.

    1997-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goal of this project was to develop a new electron bunch compression technology, experimentally demonstrate subpicosecond compression of bunches with charges on the order of 1 nC, and to theoretically investigate fundamental limitations to electron bunch compression. All of these goals were achieved, and in addition, the compression system built for this project was used to generate 22 nm light in a plasma-radiator light source

  2. Bunch monitor for an S-band electron linear accelerator

    International Nuclear Information System (INIS)

    Otake, Yuji; Nakahara, Kazuo

    1991-01-01

    The measurement of bunch characteristics in an S-band electron linear accelerator is required in order to evaluate the quality of accelerated electron beams. A new-type bunch monitor has been developed which combines micro-stripline technology with an air insulator and wall-current monitoring technology. The obtained time resolution of the monitor was more than 150 ps. This result shows that the monitor can handle the bunch number of an S-band linac. The structure of the monitor is suitable for being installed in the vacuum area, since it is constructed of only metal and ceramic parts. It can therefore easily be employed in an actual machine

  3. Experimental results on electron beam combination and bunch frequency multiplication

    Directory of Open Access Journals (Sweden)

    Roberto Corsini

    2004-04-01

    Full Text Available The aim of the CLIC Test Facility CTF3 at CERN is to demonstrate the feasibility of the key points of the two-beam acceleration based compact linear collider study. In particular, it addresses the efficient generation of a drive beam with the appropriate time structure of the electron bunches in order to produce high power rf pulses at a frequency of 30 GHz. This time structure requires a high bunch repetition frequency. It is obtained by successive injections of bunch trains into an isochronous ring using transversely deflecting rf structures. The major goal of the now completed first phase of the CTF3 was to achieve the bunch train combination at low charge. In this paper, we give a description of the project and summarize the experimental results, with a focus on the successful bunch frequency multiplication for various factors up to 5.

  4. Electron bunch length measurement with a wakefield radiation decelerator

    Directory of Open Access Journals (Sweden)

    Weiwei Li

    2014-03-01

    Full Text Available In this paper, we propose a novel method to measure the electron bunch length with a dielectric wakefield radiation (DWR decelerator which is composed of two dielectric-lined waveguides (DLWs and an electron spectrometer. When an electron beam passes through a DLW, the DWR is excited which leads to an energy loss of the electron beam. The energy loss is found to be largely dependent on the electron bunch length and can be easily measured by an electron spectrometer which is essential for a normal accelerator facility. Our study shows that this method has a high resolution and a great simplicity.

  5. Minimizing Slope and Kick of Intermediate Bunches for Electron Cooling

    Science.gov (United States)

    Dotson, Andrew

    2017-09-01

    Ions in the Jefferson Lab Electron-Ion Collider (JLEIC) will have transverse energy, which limits the beams density. Electron cooling is a process by which a beam of bunched electrons with small transverse kinetic energy is directed along the ion beam with the same velocity. The ions transfer their transverse kinetic energy to the electron bunches, making the ions lose transverse energy. Electron bunches will be supplied by an electron gun. The required current needed to cool the ion beam can be reached by reusing electrons and incorporating RF kicker cavities to supply a pulsed electric field that kicks every 11th bunch out of the cooling ring. This provides an exact solution that yields zero kick and slope to all intermediate bunches in the cooling ring, which is described by a cosine series with 11 terms. The goal of this project is to determine if solutions exist that are sufficiently close to zero kick and slope, but require less than 4 kicker cavities. The method used to find these solutions is minimizing an objective function through Sequential Least Squares Programming (SLSQP). A Pareto front then demonstrated the average kick vs. average slope when using 1 through 4 kickers.

  6. Sub-fs electron bunch generation with sub-10-fs bunch arrival-time jitter via bunch slicing in a magnetic chicane

    Directory of Open Access Journals (Sweden)

    J. Zhu

    2016-05-01

    Full Text Available The generation of ultrashort electron bunches with ultrasmall bunch arrival-time jitter is of vital importance for laser-plasma wakefield acceleration with external injection. We study the production of 100-MeV electron bunches with bunch durations of subfemtosecond (fs and bunch arrival-time jitters of less than 10 fs, in an S-band photoinjector by using a weak magnetic chicane with a slit collimator. The beam dynamics inside the chicane is simulated by using two codes with different self-force models. The first code separates the self-force into a three-dimensional (3D quasistatic space-charge model and a one-dimensional coherent synchrotron radiation (CSR model, while the other one starts from the first principle with a so-called 3D sub-bunch method. The simulations indicate that the CSR effect dominates the horizontal emittance growth and the 1D CSR model underestimates the final bunch duration and emittance because of the very large transverse-to-longitudinal aspect ratio of the sub-fs bunch. Particularly, the CSR effect is also strongly affected by the vertical bunch size. Due to the coupling between the horizontal and longitudinal phase spaces, the bunch duration at the entrance of the last dipole magnet of the chicane is still significantly longer than that at the exit of the chicane, which considerably mitigates the impact of space charge and CSR effects on the beam quality. Exploiting this effect, a bunch charge of up to 4.8 pC in a sub-fs bunch could be simulated. In addition, we analytically and numerically investigate the impact of different jitter sources on the bunch arrival-time jitter downstream of the chicane, and define the tolerance budgets assuming realistic values of the stability of the linac for different bunch charges and compression schemes.

  7. Velocity bunching of high-brightness electron beams

    Directory of Open Access Journals (Sweden)

    S. G. Anderson

    2005-01-01

    Full Text Available Velocity bunching has been recently proposed as a tool for compressing electron beam pulses in modern high brightness photoinjector sources. This tool is familiar from earlier schemes implemented for bunching dc electron sources, but presents peculiar challenges when applied to high current, low emittance beams from photoinjectors. The main difficulty foreseen is control of emittance oscillations in the beam in this scheme, which can be naturally considered as an extension of the emittance compensation process at moderate energies. This paper presents two scenarios in which velocity bunching, combined with emittance control, is to play a role in nascent projects. The first is termed ballistic bunching, where the changing of relative particle velocities and positions occur in distinct regions, a short high gradient linac, and a drift length. This scenario is discussed in the context of the proposed ORION photoinjector. Simulations are used to explore the relationship between the degree of bunching, and the emittance compensation process. Experimental measurements performed at the UCLA Neptune Laboratory of the surprisingly robust bunching process, as well as accompanying deleterious transverse effects, are presented. An unanticipated mechanism for emittance growth in bends for highly momentum chirped beam was identified and studied in these experiments. The second scenario may be designated as phase space rotation, and corresponds closely to the recent proposal of Ferrario and Serafini. Its implementation for the compression of the electron beam pulse length in the PLEIADES inverse Compton scattering (ICS experiment at LLNL is discussed. It is shown in simulations that optimum compression may be obtained by manipulation of the phases in low gradient traveling wave accelerator sections. Measurements of the bunching and emittance control achieved in such an implementation at PLEIADES, as well as aspects of the use of velocity-bunched beam directly

  8. Enhanced coherent undulator radiation from bunched electron beams

    International Nuclear Information System (INIS)

    Berryman, K.W.; Crosson, E.R.; Ricci, K.N.; Smith, T.I.

    1996-01-01

    When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10 4 using electron bunch compression. copyright 1996 American Institute of Physics

  9. Optical plasma torch electron bunch generation in plasma wakefield accelerators

    Directory of Open Access Journals (Sweden)

    G. Wittig

    2015-08-01

    Full Text Available A novel, flexible method of witness electron bunch generation in plasma wakefield accelerators is described. A quasistationary plasma region is ignited by a focused laser pulse prior to the arrival of the plasma wave. This localized, shapeable optical plasma torch causes a strong distortion of the plasma blowout during passage of the electron driver bunch, leading to collective alteration of plasma electron trajectories and to controlled injection. This optically steered injection is more flexible and faster when compared to hydrodynamically controlled gas density transition injection methods.

  10. Simple method for generating adjustable trains of picosecond electron bunches

    Directory of Open Access Journals (Sweden)

    P. Muggli

    2010-05-01

    Full Text Available A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.

  11. Measurement of electron beam bunch phase length by rectangular cavities

    International Nuclear Information System (INIS)

    Afanas'ev, V.D.; Rudychev, V.G.; Ushakov, V.I.

    1976-01-01

    An analysis of a phase length of electron bunches with the help of crossed rectangular resonators with the Hsub(102) oscillation type has been made. It has been shown that the electron coordinates after the duplex resonator are described by an ellipse equation for a non-modulated beam. An influence of the initial energy spread upon the electron motion has been studied. It has been ascertained that energy modulation of the electron beam results in displacement of each electron with respect to the ellipse which is proportional to modulation energy, i.e. an error in determination of the phase length of an electron bunch is proportional to the beam energy spread. Relations have been obtained which enable to find genuine values of phases of the analyzed electrons with an accuracy up to linear multipliers

  12. Experimental study of EUV mirror radiation damage resistance under long-term free-electron laser exposures below the single-shot damage threshold

    Czech Academy of Sciences Publication Activity Database

    Makhotkin, I.; Sobierajski, R.; Chalupský, Jaromír; Tiedtke, K.; de Vries, G.; Stoermer, M.; Scholze, F.; Siewert, F.; van de Kruijs, R.W.E.; Milov, I.; Louis, E.; Jacyna, I.; Jurek, M.; Klinger, D.; Nittler, L.; Syryanyy, Y.; Juha, Libor; Hájková, Věra; Vozda, Vojtěch; Burian, Tomáš; Saksl, Karel; Faatz, B.; Keitel, B.; Ploenjes, E.; Schreiber, S.; Toleikis, S.; Loch, R.A.; Hermann, M.; Strobel, S.; Nienhuys, H.-K.; Gwalt, G.; Mey, T.; Enkisch, H.

    2018-01-01

    Roč. 25, č. 1 (2018), s. 77-84 ISSN 1600-5775. [Workshop on FEL Photon Diagnostics, Instrumentation and Beamline Design (PhotonDiag2017). Stanford, 01.05.2017-03.05.2017] R&D Projects: GA MŠk LG15013; GA ČR(CZ) GA17-05167s; GA ČR(CZ) GA14-29772S Institutional support: RVO:68378271 Keywords : free-electron laser induced damage * EUV optics * thin films * FELs Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.011, year: 2016

  13. Mode-Locked Multichromatic X-Rays in a Seeded Free-Electron Laser for Single-Shot X-Ray Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Dao; Ding, Yuantao; Raubenheimer, Tor; Wu, Juhao; /SLAC

    2012-05-10

    We present the promise of generating gigawatt mode-locked multichromatic x rays in a seeded free-electron laser (FEL). We show that, by using a laser to imprint periodic modulation in electron beam phase space, a single-frequency coherent seed can be amplified and further translated to a mode-locked multichromatic output in an FEL. With this configuration the FEL output consists of a train of mode-locked ultrashort pulses which span a wide frequency gap with a series of equally spaced sharp lines. These gigawatt multichromatic x rays may potentially allow one to explore the structure and dynamics of a large number of atomic states simultaneously. The feasibility of generating mode-locked x rays ranging from carbon K edge ({approx}284 eV) to copper L{sub 3} edge ({approx}931 eV) is confirmed with numerical simulation using the realistic parameters of the linac coherent light source (LCLS) and LCLS-II. We anticipate that the mode-locked multichromatic x rays in FELs may open up new opportunities in x-ray spectroscopy (i.e. resonant inelastic x-ray scattering, time-resolved scattering and spectroscopy, etc.).

  14. Properties of Trapped Electron Bunches in a Plasma Wakefield Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kirby, Neil; /SLAC

    2009-10-30

    Plasma-based accelerators use the propagation of a drive bunch through plasma to create large electric fields. Recent plasma wakefield accelerator (PWFA) experiments, carried out at the Stanford Linear Accelerator Center (SLAC), successfully doubled the energy for some of the 42 GeV drive bunch electrons in less than a meter; this feat would have required 3 km in the SLAC linac. This dissertation covers one phenomenon associated with the PWFA, electron trapping. Recently it was shown that PWFAs, operated in the nonlinear bubble regime, can trap electrons that are released by ionization inside the plasma wake and accelerate them to high energies. These trapped electrons occupy and can degrade the accelerating portion of the plasma wake, so it is important to understand their origins and how to remove them. Here, the onset of electron trapping is connected to the drive bunch properties. Additionally, the trapped electron bunches are observed with normalized transverse emittance divided by peak current, {epsilon}{sub N,x}/I{sub t}, below the level of 0.2 {micro}m/kA. A theoretical model of the trapped electron emittance, developed here, indicates that the emittance scales inversely with the square root of the plasma density in the non-linear 'bubble' regime of the PWFA. This model and simulations indicate that the observed values of {epsilon}{sub N,x}/I{sub t} result from multi-GeV trapped electron bunches with emittances of a few {micro}m and multi-kA peak currents. These properties make the trapped electrons a possible particle source for next generation light sources. This dissertation is organized as follows. The first chapter is an overview of the PWFA, which includes a review of the accelerating and focusing fields and a survey of the remaining issues for a plasma-based particle collider. Then, the second chapter examines the physics of electron trapping in the PWFA. The third chapter uses theory and simulations to analyze the properties of the trapped

  15. Theoretical analysis and simulation study of the deep overcompression mode of velocity bunching for a comblike electron bunch train

    Science.gov (United States)

    Wang, Dan; Yan, Lixin; Du, YingChao; Huang, Wenhui; Gai, Wei; Tang, Chuanxiang

    2018-02-01

    Premodulated comblike electron bunch trains are used in a wide range of research fields, such as for wakefield-based particle acceleration and tunable radiation sources. We propose an optimized compression scheme for bunch trains in which a traveling wave accelerator tube and a downstream drift segment are together used as a compressor. When the phase injected into the accelerator tube for the bunch train is set to ≪-10 0 ° , velocity bunching occurs in a deep overcompression mode, which reverses the phase space and maintains a velocity difference within the injected beam, thereby giving rise to a compressed comblike electron bunch train after a few-meter-long drift segment; we call this the deep overcompression scheme. The main benefits of this scheme are the relatively large phase acceptance and the uniformity of compression for the bunch train. The comblike bunch train generated via this scheme is widely tunable: For the two-bunch case, the energy and time spacings can be continuously adjusted from +1 to -1 MeV and from 13 to 3 ps, respectively, by varying the injected phase of the bunch train from -22 0 ° to -14 0 ° . Both theoretical analysis and beam dynamics simulations are presented to study the properties of the deep overcompression scheme.

  16. Production and characterization of attosecond electron bunch trains

    Directory of Open Access Journals (Sweden)

    Christopher M. S. Sears

    2008-06-01

    Full Text Available We report the production of optically spaced attosecond electron microbunches produced by the inverse free-electron-laser (IFEL process. The IFEL is driven by a Ti:sapphire laser synchronized with the electron beam. The IFEL is followed by a magnetic chicane that converts the energy modulation into the longitudinal microbunch structure. The microbunch train is characterized by observing coherent optical transition radiation (COTR at multiple harmonics of the bunching. Experimental results are compared with 1D analytic theory showing good agreement. Estimates of the bunching factors are given and correspond to a microbunch length of 410 attosec FWHM. The formation of stable attosecond electron pulse trains marks an important step towards direct laser acceleration.

  17. Measuring the electron bunch timing with femtosecond resolution at FLASH

    International Nuclear Information System (INIS)

    Bock, Marie Kristin

    2013-03-01

    Bunch arrival time monitors (BAMs) are an integral part of the laser-based synchronisation system which is being developed at the Free Electron Laser in Hamburg (FLASH).The operation principle comprises the measurement of the electron bunch arrival time relative to the optical timing reference, which is provided by actively length-stabilised fibre-links of the synchronisation system. The monitors are foreseen to be used as a standard diagnostic tool, not only for FLASH but also for the future European X-Ray Free-Electron Laser (European XFEL). The present bunch arrival time monitors have evolved from proof-of-principle experiments to beneficial diagnostic devices, which are almost permanently available during standard machine operation. This achievement has been a major objective of this thesis. The developments went in parallel to improvements in the reliable and low-maintenance operation of the optical synchronisation system. The key topics of this thesis comprised the characterisation and optimisation of the opto-mechanical front-ends of both, the fibre-links and the BAMs. The extent of applications involving the bunch arrival time information has been enlarged, providing automated measurements for properties of the RF acceleration modules, for instance, the RF on-crest phase determination and the measurement of energy fluctuations. Furthermore, two of the currently installed BAMs are implemented in an active phase and gradient stabilisation of specific modules in order to minimise the arrival time jitter of the electron bunches at the location of the FEL undulators, which is crucial for a high timing resolution of pump-probe experiments.

  18. Measuring the electron bunch timing with femtosecond resolution at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Bock, Marie Kristin

    2013-03-15

    Bunch arrival time monitors (BAMs) are an integral part of the laser-based synchronisation system which is being developed at the Free Electron Laser in Hamburg (FLASH).The operation principle comprises the measurement of the electron bunch arrival time relative to the optical timing reference, which is provided by actively length-stabilised fibre-links of the synchronisation system. The monitors are foreseen to be used as a standard diagnostic tool, not only for FLASH but also for the future European X-Ray Free-Electron Laser (European XFEL). The present bunch arrival time monitors have evolved from proof-of-principle experiments to beneficial diagnostic devices, which are almost permanently available during standard machine operation. This achievement has been a major objective of this thesis. The developments went in parallel to improvements in the reliable and low-maintenance operation of the optical synchronisation system. The key topics of this thesis comprised the characterisation and optimisation of the opto-mechanical front-ends of both, the fibre-links and the BAMs. The extent of applications involving the bunch arrival time information has been enlarged, providing automated measurements for properties of the RF acceleration modules, for instance, the RF on-crest phase determination and the measurement of energy fluctuations. Furthermore, two of the currently installed BAMs are implemented in an active phase and gradient stabilisation of specific modules in order to minimise the arrival time jitter of the electron bunches at the location of the FEL undulators, which is crucial for a high timing resolution of pump-probe experiments.

  19. Bunch length diagnostics with coherent relativistic electron radiation

    CERN Document Server

    Ayzatsky, M I; Kushnir, V A; Mitrochenko, V V

    2001-01-01

    One of the most important problems when designing resonance electron linacs with a high beam brightness is creation of an equipment for electron bunch length diagnostics. One of ways to solve this problem is based on analysis of radiation from relativistic electrons (transition,synchrotron etc.). The paper presents results of calculations and experiments on studying the millimeter-band radiation that is a beam exited on the surface of the grating periodic structure and in a linac beam pipe. Experiments were carried out on the linac LIC with 13 MeV particle energy and 0.8 A pulse beam current. The possibility of observed radiation application for estimation of the bunch length value, monitoring its variation and for optimization of the accelerator operating mode was shown experimentally.

  20. Real-time monitoring of longitudinal electron bunch parameters by intensity-integrated and spectroscopic measurements of single coherent THz pulses; Echtzeitbestimmung longitudinaler Elektronenstrahlparameter mittels absoluter Intensitaets- und Spektralmessung einzelner kohaerenter THz Strahlungspulse

    Energy Technology Data Exchange (ETDEWEB)

    Wesch, Stephan

    2012-12-15

    High-gain free-electron lasers (FELs) generate intense and monochromatic photon pulses with few tens of femtosecond duration. For this purpose, electron beams are accelerated to relativistic energies and shrunk longitudinally down to micrometer size.The diagnosis of theses compressed electron bunches is a challenge especially for MHz bunch repetition rates as provided by the FEL FLASH in Hamburg. In this thesis, coherently emitted THz radiation of single electron bunches were investigated, on which the longitudinal structure is imprinted. Two instruments were used: First, the FLASH bunch compression monitors, relying on the integrated intensity measurement of diffraction radiation, were modified to determine the overall length of every bunch behind the two bunch compressors (BC). A model was developed showing that their response is independent of the exact bunch shape for lengths below 200 {mu}m (rms). This could experimentally be verified in the range between 50 and 190 {mu}m within 7% accuracy for themonitor behind the last BC by comparison with measurements with the transverse deflecting structure (TDS). Second, a single-shot spectrometer with five staged reflective blazed gratings has been designed, build and commissioned. With its two grating sets, the wavelength ranges from 5.5 to 44 {mu}m and 45 to 440 {mu}m can be simultaneously detected by 118 fast pyroelectric elements. Measurements based on transition radiation spectra were compared with profiles recorded by the TDS.The shape of the spectra as well as the reconstructed temporal profiles (using the Kramers-Kronig relation for phase retrieval) are in excellent agreement. For bunches with a charge of 50 pC, bunch lengths down to 5 {mu}m (fhwm) could be detected.

  1. Investigation of transient processes at the DELTA electron storage ring using a digital bunch-by-bunch feedback system

    Energy Technology Data Exchange (ETDEWEB)

    Hoener, Markus

    2015-07-01

    At the 1.5-GeV synchrotron radiation source DELTA, operated by the TU Dortmund University, intensive synchrotron radiation in the spectral range from hard X-rays to THz radiation is generated by the circular deflection of highly relativistic electron bunches. Interacting with the vacuum chamber wall, the electron bunches create electric fields, which can act back on subsequent bunches. With increasing beam current, the excitation is enhanced so that the electron beam is unstable, which means that the electron bunches oscillate longitudinally or transversely relative to their reference position. The oscillations reduce the quality of the synchrotron radiation and limit the maximum storable beam current. Within the scope of this thesis, the beam instabilities at the storage ring were systematically investigated. A digital bunch-by-bunch feedback system was installed and commissioned, which allows to detect and digitize the position of each electron bunch at each turn. Based on the input signal, a correction signal is calculated in order to suppress transverse and longitudinal oscillation of the bunches. In addition, it is possible to excite dedicated bunches. The systematic excitation of all coupled-bunch modes allowed for the first time to determine the damping rates of all 192 eigenmodes of the electron beam. The current dependence of the damping rates was investigated and an instability threshold was found. Besides the investigation of multibunch instabilities, single-bunch instabilities are discussed. In addition, the acquisition unit of the digital feedback system can be triggered on external events. This was used to investigate the injection process and beam losses. It was shown that the transverse feedback system increases the injection efficiency. Another aspect of this thesis is the improvement of the signal quality of ultrashort coherent synchrotron radiation pulses, which are generated by the short-pulse facility at DELTA. The short-pulse facility is based

  2. Theory of longitudinal instability for bunched electron and proton beams

    International Nuclear Information System (INIS)

    Ruggiero, A.G.

    1977-01-01

    A discussion is given of an original approach for the treatment of the longitudinal stability of high-intensity proton and electron bunches. The general analysis is divided in three steps. First, a search is made for a stationary bunch distribution which is matched to the external rf forces as well as to the current dependent induced fields. The existence of such distribution is questioned. Second, the stability of the stationary solution is checked by applying a small perturbation and observing whether this is initially damped or not. At this point a stability condition is derived in terms of current, surrounding impedance and bunch size. In the last step one should question what happens to the beam in case the stability condition is not satisfied. The problem here is the determination of the final bunch configuration. The originality of the approach stays in the combination of the three steps. All previous theories either consider only the first step or combine the second and third ones but disregard the first

  3. Electron Bunch Length Measurement for LCLS at SLAC

    International Nuclear Information System (INIS)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.

    2007-01-01

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab(trademark) using the EPICS/Channel Access Interface for Scilab(trademark) and Matlab(trademark) (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort

  4. Electron Bunch Length Measurement for LCLS at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.; /SLAC

    2007-10-04

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab{trademark} using the EPICS/Channel Access Interface for Scilab{trademark} and Matlab{trademark} (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort.

  5. Bunch lengthening with bifurcation in electron storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-San; Hirata, Kohji [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1996-08-01

    The mapping which shows equilibrium particle distribution in synchrotron phase space for electron storage rings is discussed with respect to some localized constant wake function based on the Gaussian approximation. This mapping shows multi-periodic states as well as double bifurcation in dynamical states of the equilibrium bunch length. When moving around parameter space, the system shows a transition/bifurcation which is not always reversible. These results derived by mapping are confirmed by multiparticle tracking. (author)

  6. Measuring the electron beam energy in a magnetic bunch compressor

    International Nuclear Information System (INIS)

    Hacker, Kirsten

    2010-09-01

    Within this thesis, work was carried out in and around the first bunch compressor chicane of the FLASH (Free-electron LASer in Hamburg) linear accelerator in which two distinct systems were developed for the measurement of an electron beams' position with sub-5 μm precision over a 10 cm range. One of these two systems utilized RF techniques to measure the difference between the arrival-times of two broadband electrical pulses generated by the passage of the electron beam adjacent to a pickup antenna. The other system measured the arrival-times of the pulses from the pickup with an optical technique dependent on the delivery of laser pulses which are synchronized to the RF reference of the machine. The relative advantages and disadvantages of these two techniques are explored and compared to other available approaches to measure the same beam property, including a time-of-flight measurement with two beam arrival-time monitors and a synchrotron light monitor with two photomultiplier tubes. The electron beam position measurement is required as part of a measurement of the electron beam energy and could be used in an intra-bunch-train beam-based feedback system that would stabilize the amplitude of the accelerating field. By stabilizing the accelerating field amplitude, the arrival-time of the electron beam can be made more stable. By stabilizing the electron beam arrival-time relative to a stable reference, diagnostic, seeding, and beam-manipulation lasers can be synchronized to the beam. (orig.)

  7. Coherent spontaneous radiation from highly bunched electron beams

    International Nuclear Information System (INIS)

    Berryman, K.W.; Crosson, E.R.; Ricci, K.N.

    1995-01-01

    Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10 4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques

  8. Tunable subpicosecond electron bunch train generation using a transverse-to-longitudinal phase space exchange technique

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Y.-E; /Fermilab; Piot, P.; Johnson, A.; /Fermilab /Northern Illinois U.; Lumpkin, A.H.; /Fermilab; Maxwell, T.J.; /Fermilab /Northern Illinois U.; Ruan, J.; Thurman-Keup, R.; /Fermilab

    2010-11-01

    We report on the experimental generation of a train of subpicosecond electron bunches. The bunch train generation is accomplished using a beamline capable of exchanging the coordinates between the horizontal and longitudinal degrees of freedom. An initial beam consisting of a set of horizontally-separated beamlets is converted into a train of bunches temporally separated with tunable bunch duration and separation. The experiment reported in this Letter unambiguously demonstrates the conversion process and its versatility.

  9. A fifth harmonic rf bunch monitor for the ANL-APS electron linac

    International Nuclear Information System (INIS)

    Nassiri, A.; Grelick, A.

    1993-01-01

    The function of a fifth harmonic (14.28 GHz) bunch monitor is to provide a signal which is proportional to the electron beam bunch size. The monitoring of the rf power signal at 14.28 GHz enables the operator to optimize the rf bunching of the beam at the end of the first accelerating section where the full bunching has been formed and remains mainly constant in size throughout the rest of the electron linac. A modified version of the SLAC original bunch monitor has been fabricated and its rf properties measured. This paper describes the design and the initial measurement results

  10. Multiple bunch longitudinal dynamics measurements at the Cornell Electron-Positron Storage Ring

    Directory of Open Access Journals (Sweden)

    R. Holtzapple

    2001-01-01

    Full Text Available The Cornell Electron-Positron Storage Ring (CESR has a longitudinal dipole-coupled-bunch instability that limits the total amount of current that can be stored in the ring without feedback. As a result, it is one of the major limitations for higher stored current and luminosity. This paper reports the measurements of multiple bunch longitudinal dynamics done on CESR with a streak camera. The camera was used to measure the dependence of the bunch distribution on current and accelerating rf voltage, for multiple bunches stored in CESR, as well as the effects of the longitudinal instability on the bunch distribution. Measurements of the beam's longitudinal bunch distribution with multiple bunches present in the ring help give an understanding of the instability, how it affects the bunch distribution, and possibly give insight into a cure of the instability.

  11. Nonrelativistic electron bunch train for coherently enhanced terahertz radiation sources

    International Nuclear Information System (INIS)

    Li Yuelin; Kim, Kwang-Je

    2008-01-01

    We propose to generate a train of prebunched electron beams for producing coherently enhanced Smith-Purcell radiation [S. J. Smith and E. M. Purcell, Phys. Rev. 92, 1069 (1953)] in the terahertz wavelength range. In this scheme, a train of picosecond laser pulses is produced to drive a photoemission gun to generate a train of 50 keV electron pulses. The parameters are chosen so that the space-charge effect does not destroy the pulse time structure. Smith-Purcell radiation from the electron pulse train is enhanced due both to the short length of the individual electron bunch and to the repetitive structure of the beam. Example systems producing coherent terahertz power at about 1 mW are described

  12. Comparison of beam bunching in amplifier and SASE modes at the CEA-CESTA free-electron laser

    CERN Document Server

    Donohue, J T; Lefèvre, T; Marchese, G; Padois, M; Rullier, J L

    1999-01-01

    In previous studies of bunching we operated our 2.2 MeV, 800 A single shot FEL in the amplifier mode, and observed output power and bunching not only at the injected frequency of 35 GHz but also at the second-FEL resonant frequency near 3 GHz. In order to study the mechanism of the low-frequency bunching we have performed a series of measurements in SASE mode. Here we compare and contrast results obtained in these two modes. For both modes a detailed study of the formation of the low-frequency bunches during the pulse has been performed using a streak camera, as a function of both position in the wiggler and time in the pulse. Analysis of the images shows that despite the great difference in output power, the strong bunching we see is quite similar. In the amplifier mode the coexistence of the bunching at high frequency masks some of the details of the low-frequency bunch formation, whereas in the SASE mode the temporal and spatial behavior of bunching at 3 GHz is clearly seen.

  13. Measuring the electron beam energy in a magnetic bunch compressor

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Kirsten

    2010-09-15

    Within this thesis, work was carried out in and around the first bunch compressor chicane of the FLASH (Free-electron LASer in Hamburg) linear accelerator in which two distinct systems were developed for the measurement of an electron beams' position with sub-5 {mu}m precision over a 10 cm range. One of these two systems utilized RF techniques to measure the difference between the arrival-times of two broadband electrical pulses generated by the passage of the electron beam adjacent to a pickup antenna. The other system measured the arrival-times of the pulses from the pickup with an optical technique dependent on the delivery of laser pulses which are synchronized to the RF reference of the machine. The relative advantages and disadvantages of these two techniques are explored and compared to other available approaches to measure the same beam property, including a time-of-flight measurement with two beam arrival-time monitors and a synchrotron light monitor with two photomultiplier tubes. The electron beam position measurement is required as part of a measurement of the electron beam energy and could be used in an intra-bunch-train beam-based feedback system that would stabilize the amplitude of the accelerating field. By stabilizing the accelerating field amplitude, the arrival-time of the electron beam can be made more stable. By stabilizing the electron beam arrival-time relative to a stable reference, diagnostic, seeding, and beam-manipulation lasers can be synchronized to the beam. (orig.)

  14. Coherent Smith-Purcell radiation as a diagnostic for sub-picosecond electron bunch length

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1996-01-01

    We suggest a novel technique of measuring sub-picosecond electron bunch length base on coherent Smith-Purcell radiation (SPR) emitted when electrons pass close to the surface of a metal grating. With electron bunch lengths comparable to the grating period, we predict that coherent SPR will be emitted at large angles with respect to direction of beam propagation. As the bunch length shortens, the coherent SPR will be enhanced over the incoherent component that is normally observed at small angles. Furthermore, the angular distribution of the coherent SPR will be shifted toward smaller angles as the bunch length becomes much smaller than the grating period. By measuring the angular distribution of the coherent SPR, one can determine the bunch length of sub-picosecond electron pulses. This new technique is easy to implement and appears capable of measuring femtosecond electron bunch lengths

  15. Evanescent-wave acceleration of femtosecond electron bunches

    CERN Document Server

    Zawadzka, J; Carey, J J; Wynne, K

    2000-01-01

    A 150-fs 800-nm 1-mu J laser was used to excited surface plasmons in the Kretschmann geometry in a 500-A silver film. Multiphoton excitation results in the emission of femtosecond electron bunches (40 fC) as had been seen before. The electron beam is highly directional and perpendicular to the prism surface. A time-of-flight setup has been used to measure the kinetic-energy distribution of the photoelectrons. Surprisingly, we find that this distribution extends to energies as high as 40 eV. Theoretical calculations show that these high energies may be due to acceleration in the evanescent laser field that extends from the silver film out into the vacuum. These results suggest that femtosecond pulses with more energy per pulse or longer wavelength may be used to accelerate electrons to the keV or even MeV level.

  16. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposures

    NARCIS (Netherlands)

    Khorsand, A.R.; Sobierajski, R.; Louis, Eric; Bruijn, S.; Gleeson, A.; van de Kruijs, Robbert Wilhelmus Elisabeth; Gullikson, E.M.; Bijkerk, Frederik

    2010-01-01

    We investigated single shot damage of Mo/Si multilayer coatings exposed to the intense fs XUV radiation at the Free-electron LASer facility in Hamburg - FLASH. The interaction process was studied in situ by XUV reflectometry, time resolved optical microscopy, and “post-mortem” by

  17. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  18. Beam dynamics performances and applications of a low-energy electron-beam magnetic bunch compressor

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, C. R.; Piot, P.; Carlsten, B. E.; Church, M.

    2013-08-01

    Many front-end applications of electron linear accelerators rely on the production of temporally compressed bunches. The shortening of electron bunches is often realized with magnetic bunch compressors located in high-energy sections of accelerators. Magnetic compression is subject to collective effects including space charge and self interaction via coherent synchrotron radiation. In this paper we explore the application of magnetic compression to low-energy (~40MeV), high-charge (nC) electron bunches with low normalized transverse emittances (<5@mm).

  19. Interaction of relativistic short proton bunches with space charge limited electron clouds

    Directory of Open Access Journals (Sweden)

    F. B. Petrov

    2014-12-01

    Full Text Available The electron cloud buildup and interaction with a train of relativistic, short proton bunches is studied using particle-in-cell codes. The simulation models describe the electron generation at the beam pipe wall as well as the wakefield behind the bunches. The study focuses on the space charge limited (saturated cloud profile between the bunches and on the incoherent tune spread caused by the interaction of the saturated cloud with individual bunches. Analytical expressions describing the pinch of a saturated electron cloud are derived and compared to simulation results.

  20. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  1. Investigation of focusing of relativistic electron and positron bunches moving in cold plasma. Final report

    International Nuclear Information System (INIS)

    Amatuni, A.Ts.; Elbakian, S.S.; Khachatryan, A.G.; Sekhpossian, E.V.

    1995-03-01

    This document is the final report on a project to study focusing effects of relativistic beams of electrons and positrons interacting with a cold plasma. The authors consider three different models for the overdense cold plasma - electron bunch interaction. They look at coulomb effects, wakefield effects, bunch parameters, and the effects of trains of pulses on focusing properties

  2. Methods For Electron Bunch Measurement With Resolution Of The Order Of 1 Fs And 1 Nm

    CERN Document Server

    Tron, A M

    2004-01-01

    Methods for bunch length and shape monitoring with femtosecond resolution by means of time converting photochronography of the bunch radiation in the range of visible light using photoelectron camera of new principle of its operation, and for monitoring the transverse bunch size, based on new beam cross section wire scanner technique where the depth of electron escapement being not more than 1 nm is used, are described. Main limitation, caused by space charge effect, is considered.

  3. An Electron Bunch Compression Scheme for a Superconducting Radio Frequency Linear Accelerator Driven Light Source

    Energy Technology Data Exchange (ETDEWEB)

    C. Tennant, S.V. Benson, D. Douglas, P. Evtushenko, R.A. Legg

    2011-09-01

    We describe an electron bunch compression scheme suitable for use in a light source driven by a superconducting radio frequency (SRF) linac. The key feature is the use of a recirculating linac to perform the initial bunch compression. Phasing of the second pass beam through the linac is chosen to de-chirp the electron bunch prior to acceleration to the final energy in an SRF linac ('afterburner'). The final bunch compression is then done at maximum energy. This scheme has the potential to circumvent some of the most technically challenging aspects of current longitudinal matches; namely transporting a fully compressed, high peak current electron bunch through an extended SRF environment, the need for a RF harmonic linearizer and the need for a laser heater. Additional benefits include a substantial savings in capital and operational costs by efficiently using the available SRF gradient.

  4. Simulation of wake potentials induced by relativistic proton bunches in electron clouds

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Fedor; Boine-Frankenheim, Oliver; Weiland, Thomas [Technische Universitaet Darmstadt (Germany). Institut fuer Theorie Elektromagnetischer Felder (TEMF)

    2012-07-01

    Electron clouds limit the intensity of modern high intensity hadron accelerators. Presently electron clouds are the main limiting factor for the LHC operation with 25 ns bunch trains. The bunches passing through an electron cloud induce a wake field. When the electron cloud density exceeds a certain threshold beam instabilities occur. The presence of electron clouds results in a shift of the synchronous phase, which increases if the bunch spacing is reduced. For LHC and SPS conditions we compare the longitudinal electron cloud wake potentials and stopping powers obtained using a simplified 2D electrostatic Particle-in-Cell code with fully electromagnetic simulations using VORPAL. In addition we analyze the wake fields induced by displaced or tilted bunches.

  5. Bunch compression efficiency of the femtosecond electron source at Chiang Mai University

    International Nuclear Information System (INIS)

    Thongbai, C.; Kusoljariyakul, K.; Saisut, J.

    2011-01-01

    A femtosecond electron source has been developed at the Plasma and Beam Physics Research Facility (PBP), Chiang Mai University (CMU), Thailand. Ultra-short electron bunches can be produced with a bunch compression system consisting of a thermionic cathode RF-gun, an alpha-magnet as a magnetic bunch compressor, and a linear accelerator as a post acceleration section. To obtain effective bunch compression, it is crucial to provide a proper longitudinal phase-space distribution at the gun exit matched to the subsequent beam transport system. Via beam dynamics calculations and experiments, we investigate the bunch compression efficiency for various RF-gun fields. The particle distribution at the RF-gun exit will be tracked numerically through the alpha-magnet and beam transport. Details of the study and results leading to an optimum condition for our system will be presented.

  6. Nonlinear electrostatic emittance compensation in kA, fs electron bunches

    International Nuclear Information System (INIS)

    Geer, S.B. van der; Loos, M.J. de; Botman, J.I.M.; Luiten, O.J.; Wiel, M.J. van der

    2002-01-01

    Nonlinear space-charge effects play an important role in emittance growth in the production of kA electron bunches with a bunch length much smaller than the bunch diameter. We propose a scheme employing the radial third-order component of an electrostatic acceleration field, to fully compensate the nonlinear space-charge effects. This results in minimal transverse root-mean-square emittance. The principle is demonstrated using our design simulations of a device for the production of high-quality, high-current, subpicosecond electron bunches using electrostatic acceleration in a 1 GV/m field. Simulations using the GPT code produce a bunch of 100 pC and 73 fs full width at half maximum pulse width, resulting in a peak current of about 1.2 kA at an energy of 2 MeV. The compensation scheme reduces the root-mean-square emittance by 34% to 0.4π mm mrad

  7. Numerical study of coupled-bunch instability caused by an electron cloud

    Directory of Open Access Journals (Sweden)

    S. S. Win

    2005-09-01

    Full Text Available An electron cloud induces a wake force on a charged particle beam which creates correlations between bunches—i.e., a small displacement of a bunch creates a perturbation of the electron cloud, which affects the motions of the following bunches, with the result that a coupled-bunch instability is caused. The coupling mode of the instability is determined by the motion of the electrons in the cloud—that is, it depends on which electrons, moving in a drift space, a weak solenoid field or a strong bending field, are dominant for the instability. We discuss the coupled-bunch instability focusing on the relation between the mode spectrum and the electron motion.

  8. Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

    International Nuclear Information System (INIS)

    Loehl, F.; Arsov, V.; Felber, M.; Hacker, K.; Lorbeer, B.; Ludwig, F.; Matthiesen, K.-H.; Schlarb, H.; Schmidt, B.; Winter, A.; Jalmuzna, W.; Schmueser, P.; Schulz, S.; Zemella, J.; Szewinski, J.

    2010-01-01

    High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

  9. Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

    Science.gov (United States)

    Löhl, F.; Arsov, V.; Felber, M.; Hacker, K.; Jalmuzna, W.; Lorbeer, B.; Ludwig, F.; Matthiesen, K.-H.; Schlarb, H.; Schmidt, B.; Schmüser, P.; Schulz, S.; Szewinski, J.; Winter, A.; Zemella, J.

    2010-04-01

    High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

  10. Experiment and simulations of sub-ps electron bunch train generation at Fermilab photoinjectors

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Y.-E; Church, M.; /Fermilab; Piot, P.; Prokop, C.R.; /Fermilab /Northern Illinois U.

    2011-10-01

    Recently the generation of electron bunch trains with sub-picosecond time structure has been experimentally demonstrated at the A0 photoinjector of Fermilab using a transverse-longitudinal phase-space exchange beamline. The temporal profile of the bunch train can be easily tuned to meet the requirements of the applications of modern accelerator beams. In this paper we report the A0 bunch-train experiment and explore numerically the possible extension of this technique to shorter time scales at the Fermilab SRF Accelerator Test Facility, a superconducting linear electron accelerator currently under construction in the NML building.

  11. Free electron laser with bunched relativistic electron beam and electrostatic longitudinal wiggler

    International Nuclear Information System (INIS)

    Sepehri Javan, Nasser

    2010-01-01

    The system of the nonlinear nonstationary equations describing spatial-temporal dynamics of the amplitudes of an undulator radiation and a space charge wave of a relativistic electron beam in the resonator is obtained. The electrostatic longitudinal wiggler is considered. A bunch of the electron beam injects to the resonator, at the ends of which two mirrors are placed. After the interaction of electrons of bunch with radiation in the presence of wiggler and after amplifying electromagnetic pulse, a part of radiation is reflected back by semitransparent mirror. Then, it reaches to the initial of the system where the other mirror is placed. Synchronously, when the pulse is reflecting, the other electron bunch enters to the resonator and interacts with the pulse. This operation has simulated until saturation of growth of the electromagnetic pulse. The dynamics of the problem is simulated by the method of macro particles. The dynamics of pulse amplification, motion of the electrons, and spectra of output radiation in each stage are simulated.

  12. Self-Consistent Electron-Cloud Simulation for Long Proton Bunches

    CERN Document Server

    Shishlo, Andrei P; Danilov, Viatcheslav V; Henderson, Stuart; Holmes, Jeffrey Alan; Lee, Shyh-Yuan; Macek, Robert J; Sato, Yoichi

    2005-01-01

    The results of numerical electron-cloud simulations for long-bunch proton beams in accumulator rings are presented and compared with data from the Proton Storage Ring at LANL. The frequency spectra and growth rate of proton-bunch transverse instabilities are studied as functions of the RF cavity voltage, external magnetic fields, beam pipe surface properties, and other factors. We used the recently developed electron-cloud module in the ORBIT code. The model includes a fully self-consistent coupled treatment of the "proton bunch - electron-cloud" dynamics and the multipacting process with a realistic secondary emission surface model. Realistic lattices and proton bunch distributions are used. The efficiency of electron-cloud instability suppression has also been studied using a new ORBIT model.

  13. Femtosecond X-ray Pulses from a Spatially Chirped Electron Bunch in a SASE FEL

    Energy Technology Data Exchange (ETDEWEB)

    Emma, P.

    2003-01-14

    We propose a simple method to produce short x-ray pulses using a spatially chirped electron bunch in a SASE FEL. The spatial chirp is generated using an rf deflector which produces a transverse offset (in y and/or y') correlated with the longitudinal bunch position. Since the FEL gain is very sensitive to an initial offset in the transverse phase space at the entrance of the undulator, only a small portion of the electron bunch with relatively small transverse offset will interact significantly with the radiation, resulting in an x-ray pulse length much shorter than the electron bunch length. The x-ray pulse is also naturally phase locked to the rf deflector and so allows high precision timing synchronization. We discuss the generation and transport of such a spatially chirped electron beam and show that tens of femtosecond long pulse can be generated for the linac coherent light source (LCLS).

  14. Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

    Science.gov (United States)

    He, Z.-H.; Thomas, A. G. R.; Beaurepaire, B.; Nees, J. A.; Hou, B.; Malka, V.; Krushelnick, K.; Faure, J.

    2013-02-01

    We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

  15. FEL induced electron bunch heating observed by a method based on synchronous phase detection

    CERN Document Server

    Hosaka, M; Katoh, M; Yamazaki, J; Hama, H

    2001-01-01

    A new method for monitoring instantaneous bunch length has been developed on the UVSOR storage ring. Based on the bunch length dependence of the loss factor, the bunch length can be derived from the synchronous phase shift. Experiments using this method were performed to observe the bunch lengthening associated with the free electron laser (FEL) power variation. From the detuning dependence of the bunch heating, it was found that additional energy spread mostly has a constant ratio to the intracavity laser power normalized by the beam current. However, at the best synchronism region, the induced energy spread exhibits a strong non-linearity against the normalized FEL power and hence the power saturation is accomplished.

  16. Coherent radiation characteristics of modulated electron bunch formed in stack of two plates

    Science.gov (United States)

    Gevorgyan, H. L.; Gevorgian, L. A.

    2017-07-01

    The present article is devoted to the radiation from the electron bunch with modulated density passes through the stack consisting of two plates with different thicknesses and electrodynamic properties. The new elegant expression for the frequency-angular distribution of transition radiation is obtained. Using the existence of resonant frequency at which the longitudinal form-factor of bunch not suppresses radiation coherence and choosing parameters for the stack of plates, one can also avoid suppression of the radiation coherence by transverse form-factor of bunch. The radiation from a bunch with modulated density in the process SASE (self-amplified spontaneous emission) FEL can be partially coherent at a resonant frequency. Then the intense sub monochromatic beam of X-ray photons is formed. On the other hand one can define an important parameter of the bunch density modulation depth which is unknown to this day.

  17. Application of constrained deconvolution technique for reconstruction of electron bunch profile with strongly non-Gaussian shape

    International Nuclear Information System (INIS)

    Geloni, G.; Saldin, E.L.; Schneidmiller, E.A.; Yurkov, M.V.

    2004-01-01

    An effective and practical technique based on the detection of the coherent synchrotron radiation (CSR) spectrum can be used to characterize the profile function of ultra-short bunches. The CSR spectrum measurement has an important limitation: no spectral phase information is available, and the complete profile function cannot be obtained in general. In this paper we propose to use constrained deconvolution method for bunch profile reconstruction based on a priori-known information about formation of the electron bunch. Application of the method is illustrated with practically important example of a bunch formed in a single bunch-compressor. Downstream of the bunch compressor the bunch charge distribution is strongly non-Gaussian with a narrow leading peak and a long tail. The longitudinal bunch distribution is derived by measuring the bunch tail constant with a streak camera and by using a priory available information about profile function

  18. Application of constrained deconvolution technique for reconstruction of electron bunch profile with strongly non-Gaussian shape

    Science.gov (United States)

    Geloni, G.; Saldin, E. L.; Schneidmiller, E. A.; Yurkov, M. V.

    2004-08-01

    An effective and practical technique based on the detection of the coherent synchrotron radiation (CSR) spectrum can be used to characterize the profile function of ultra-short bunches. The CSR spectrum measurement has an important limitation: no spectral phase information is available, and the complete profile function cannot be obtained in general. In this paper we propose to use constrained deconvolution method for bunch profile reconstruction based on a priori-known information about formation of the electron bunch. Application of the method is illustrated with practically important example of a bunch formed in a single bunch-compressor. Downstream of the bunch compressor the bunch charge distribution is strongly non-Gaussian with a narrow leading peak and a long tail. The longitudinal bunch distribution is derived by measuring the bunch tail constant with a streak camera and by using a priory available information about profile function.

  19. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  20. Electron cooling of a bunched ion beam in a storage ring

    Science.gov (United States)

    Zhao, He; Mao, Lijun; Yang, Jiancheng; Xia, Jiawen; Yang, Xiaodong; Li, Jie; Tang, Meitang; Shen, Guodong; Ma, Xiaoming; Wu, Bo; Wang, Geng; Ruan, Shuang; Wang, Kedong; Dong, Ziqiang

    2018-02-01

    A combination of electron cooling and rf system is an effective method to compress the beam bunch length in storage rings. A simulation code based on multiparticle tracking was developed to calculate the bunched ion beam cooling process, in which the electron cooling, intrabeam scattering (IBS), ion beam space-charge field, transverse and synchrotron motion are considered. Meanwhile, bunched ion beam cooling experiments have been carried out in the main cooling storage ring (CSRm) of the Heavy Ion Research Facility in Lanzhou, to investigate the minimum bunch length obtained by the cooling method, and study the dependence of the minimum bunch length on beam and machine parameters. The experiments show comparable results to those from simulation. Based on these simulations and experiments, we established an analytical model to describe the limitation of the bunch length of the cooled ion beam. It is observed that the IBS effect is dominant for low intensity beams, and the space-charge effect is much more important for high intensity beams. Moreover, the particles will not be bunched for much higher intensity beam. The experimental results in CSRm show a good agreement with the analytical model in the IBS dominated regime. The simulation work offers us comparable results to those from the analytical model both in IBS dominated and space-charge dominated regimes.

  1. Tunable Subpicosecond Electron-Bunch-Train Generation Using a Transverse-To-Longitudinal Phase-Space Exchange Technique

    International Nuclear Information System (INIS)

    Sun, Y.-E; Piot, P.; Maxwell, T. J.; Johnson, A.; Lumpkin, A. H.; Ruan, J.; Thurman-Keup, R.

    2010-01-01

    We report on the experimental generation of a train of subpicosecond electron bunches. The bunch train generation is accomplished using a beam line capable of exchanging the coordinates between the horizontal and longitudinal degrees of freedom. An initial beam consisting of a set of horizontally separated beamlets is converted into a train of bunches temporally separated with tunable bunch duration and separation. The experiment reported in this Letter unambiguously demonstrates the conversion process and its versatility.

  2. High quality electron bunch generation with CO2-laser-plasma interaction

    Science.gov (United States)

    Zhang, Lingang; Shen, Baifei; Xu, Jiancai; Ji, Liangliang; Zhang, Xiaomei; Wang, Wenpeng; Zhao, Xueyan; Yi, Longqing; Yu, Yahong; Shi, Yin; Xu, Tongjun; Xu, Zhizhan

    2015-02-01

    CO2 laser-driven electron acceleration in low-density plasma is demonstrated using particle-in-cell simulation. An intense CO2 laser pulse of long wavelength excites a wake bubble that has a large elongated volume for accelerating a large number of electrons before reaching the charge saturation limit. A transversely injected laser pulse is used to induce and control the electron injection. It is found that an electron bunch with total charge up to 10 nC and absolute energy spread less than 16 MeV can be obtained. As a result, the charge per energy interval of the bunch reaches up to 0.6 nC/MeV. Intense CO2-laser based electron acceleration can provide a new direction for generating highly charged electron bunches with low energy spread, which is of much current interest, especially for table-top X-ray generation.

  3. Temporal profile monitor based on electro-optic spatial decoding for low-energy bunches

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2017-11-01

    Full Text Available The measurement of electron bunch temporal profile is one of the key diagnostics in accelerators, especially for ultrashort bunches. The electro-optic (EO technique enables the precise longitudinal characterization of bunch electric field in a single-shot and nondestructive way, which can simultaneously obtain and analyze the time jitter between the electron bunch and the synchronized laser. An EO monitor based on spatial decoding for temporal profile measurement and timing jitter recoding has recently been demonstrated and analyzed in depth for low-energy bunches at the Tsinghua Thomson scattering X-ray source. A detailed description of the experimental setup and measurement results are presented in this paper. An EO signal as short as 82 fs (rms is observed with 100  μm gallium phosphide for a 40 MeV electron bunch, and the corresponding length is 106 fs (rms with 300  μm zinc telluride. Owing to the field-opening angle, we propose a method to eliminate the influence of energy factor for bunches with low energy, resulting in a bunch length of ∼60  fs (rms. The monitor is also successfully applied to measure time jitter with approximately 10 fs accuracy. The experiment environment is proved to be the main source of the slow drift, which is removed using feedback control. Consequently, the rms time jitter decreases from 430 fs to 320 fs.

  4. Bunch decompression for laser-plasma driven free-electron laser demonstration schemes

    Directory of Open Access Journals (Sweden)

    T. Seggebrock

    2013-07-01

    Full Text Available X-ray free-electron lasers (FELs require a very high electron beam quality in terms of emittance and energy spread. Since 2004 high quality electrons produced by laser-wakefield accelerators have been demonstrated, but the electron quality up to now did not allow the operation of a compact x-ray FEL using these electrons. Maier et al. [Phys. Rev. X 2, 031019 (2012PRXHAE2160-330810.1103/PhysRevX.2.031019] suggested a concept for a proof-of-principle experiment allowing FEL operation in the vacuum ultraviolet range based on an optimized undulator and bunch decompression using electron bunches from a laser-plasma accelerator as currently available. In this paper we discuss in more detail how a chicane can be used as a bunch stretcher instead of a bunch compressor to allow the operation of a laser-wakefield accelerator driven FEL using currently available electrons. A scaling characterizing the impact of bunch decompression on the gain length is derived and the feasibility of the concept is tested numerically in a demanding scenario.

  5. On the coherent radiation of an electron bunch moving in an arc of a circle

    International Nuclear Information System (INIS)

    Saldin, E.L.; Shneidmiller, E.A.; Yurkov, M.V.

    1997-01-01

    Existing theories of coherent synchrotron radiation (CSR) are related to the motion of an electron bunch on a circular orbit and do not describe the case of finite magnet length. We present the CSR theory for a bunch of any length moving in an arc of a finite angle. The radiative interaction of the electrons in the bunch is analyzed for a line charge distribution using ultrarelativistic approximation. It is shown in particular that this interaction is important not only inside the magnet but also on the straight part of the trajectory after the magnet. Detailed analytical study of the CSR effects in the electron bunch with a stepped distribution of the charge density has been performed. The simple analytical technique of the radiative force calculation has been developed. The analytical solutions in the form of elementary functions are obtained for the radiative interaction force, for the energy loss distribution along the bunch and for the total energy loss of the bunch. The latter result is confirmed with calculation of the energy of coherent radiation in far zone. The criterion for the applicability region of the preceding theories to the case of a finite magnet length is obtained

  6. Overview of Alternative Bunching and Current-shaping Techniques for Low-Energy Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Piot, Philippe [Northern Illinois U.

    2015-12-01

    Techniques to bunch or shape an electron beam at low energies (E <15 MeV) have important implications toward the realization of table-top radiation sources [1] or to the design of compact multi-user free-electron lasers[2]. This paper provides an overview of alternative methods recently developed including techniques such as wakefield-based bunching, space-charge-driven microbunching via wave-breaking [3], ab-initio shaping of the electron-emission process [4], and phase space exchangers. Practical applications of some of these methods to foreseen free-electron-laser configurations are also briefly discussed [5].

  7. On-line Observation Of Electron Beam Bunches In The Large Storage Ring Of Kurchatov Srs

    CERN Document Server

    Ioudin, L I; Krylov, Y V; Rezvov, V A; Stirin, A I; Valentinov, A G; Yupinov, Y L

    2004-01-01

    A complex of instrumentation for visual quantitative estimation of electron beam bunches in the big storage ring of Kurchatov Synchrotron Radiation Centre (KSRC) is tested. The bunches pass through a cylindrical electrostatic sensor whose signal is recorded by a wide-band oscillograph. The TV camera reads the optical image of the signal from the oscillograph screen. The TV signal numbering board inputs the video image to the computer memory. The monitor displays the beam bunch structure. A special program provides on-line visualisation of bunch behaviour on the beam orbit. The images of beam structure and a series of images showing the beam behaviour in the regimes of accumulation, acceleration and in the stationary regime a full power are numbered and stored.

  8. High-intensity coherent FIR radiation from sub-picosecond electron bunches

    International Nuclear Information System (INIS)

    Kung, P.H.; Lihn, Hung-chi; Wiedemann, H.; Bocek, D.

    1994-01-01

    A facility to generate high-intensity, ultra-short pulses of broad-band far-infrared radiation has been assembled and tested at Stanford. The device uses sub-picosecond relativistic electron bunches to generate coherent radiation through transition or synchrotron radiation in the far-infrared (FIR) regime between millimeter waves and wavelengths of about 100 μm and less. Experimental results show a peak radiation power of greater than 0.33 MW within a micro-bunch and an average FIR radiation power of 4 mW. The average bunch length of 2856 micro-bunches within a 1 μsec macro-pulse is estimated to be about 480 sec. Simulations experimental setup and results will be discussed

  9. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  10. Coherent transition radiation from a laser wakefield accelerator as an electron bunch diagnostic

    International Nuclear Information System (INIS)

    Tilborg, J. van; Geddes, C.G.R.; Toth, C.; Esarey, E.; Schroeder, C.B.; Martin, M.C.; Hao, Z.; Leemans, W.P.

    2004-01-01

    The observation and modeling of coherent transition radiation from femtosecond laser accelerated electron bunches is discussed. The coherent transition radiation, scaling quadratically with bunch charge, is generated as the electrons transit the plasma-vacuum boundary. Due to the limited transverse radius of the plasma boundary, diffraction effects will strongly modify the angular distribution and the total energy radiated is reduced compared to an infinite transverse boundary. The multi-nC electron bunches, concentrated in a length of a few plasma periods (several tens of microns), experience partial charge neutralization while propagating inside the plasma towards the boundary. This reduces the space-charge blowout of the beam, allowing for coherent radiation at relatively high frequencies (several THz). The charge distribution of the electron bunch at the plasma-vacuum boundary can be derived from Fourier analysis of the coherent part of the transition radiation spectrum. A Michelson interferometer was used to measure the coherent spectrum, and electron bunches with duration on the order of 50 fs (rms) were observed

  11. Electron Cloud Cyclotron Resonances in the Presence of a Short-bunch-length Relativistic Beam

    International Nuclear Information System (INIS)

    Celata, Christine; Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Wu, Jennifer W.

    2008-01-01

    Computer simulations using the 2D code 'POSINST' were used to study the formation of the electron cloud in the wiggler section of the positron damping ring of the International Linear Collider. In order to simulate an x-y slice of the wiggler (i.e., a slice perpendicular to the beam velocity), each simulation assumed a constant vertical magnetic field. At values of the magnetic field where the cyclotron frequency was an integral multiple of the bunch frequency, and where the field strength was less than approximately 0.6 T, equilibrium average electron densities were up to three times the density found at other neighboring field values. Effects of this resonance between the bunch and cyclotron frequency are expected to be non-negligible when the beam bunch length is much less than the product of the electron cyclotron period and the beam

  12. Space-charge effects on bunching of electrons in the CEBAF injector

    International Nuclear Information System (INIS)

    Liu, H.

    1997-01-01

    The main injector for the 4 GeV CEBAF accelerator at Thomas Jefferson national accelerator facility was designed to deliver simultaneously three CW electron beams for nuclear physics research. The maximum design current for a single beam from the injector is 100 μA, or 0.2 pC per microbunch at a repetition rate of 499 MHz. It was found through computer simulation that space charge even at a subpicocoulomb level can spoil the bunching of electrons significantly, and some unexpected phenomena observed experimentally could be explained accordingly. This problem arises because of the low-momentum tilt allowed for bunching to preserve low-momentum spread. In this paper, we analyze in detail the space-charge effects on bunching of electrons with the CEBAF injector as an example. Conditions for effective matching of longitudinal phase space in the presence of space charge are discussed. (orig.)

  13. THz wiggler applied for measurements of electron bunch longitudinal structure in FEL

    Science.gov (United States)

    Syresin, E.; Kostromin, S.; Krasilnikov, M.; Makarov, R.; Morozov, N.; Petrov, D.

    2015-01-01

    The infrared undulator manufactured at JINR and installed at FLASH in 2007 is used for longitudinal bunch shape measurements in the range of several tenths of a micrometer. The presented electromagnetic wiggler is intended for generating a narrow-band THz radiation to measure the longitudinal electron bunch structure in FELs with an electron energy of several tens of MeV. This is a planar electromagnetic device with six regular periods, each 30 cm long. The K parameter is varied in the range 0.5-7.12 corresponding to the range B = 0.025-0.356 T of the peak field on the axis. The wiggler is simulated for 19.8 MeV/ c corresponding to the possible FEL option at PITZ. The wavelength range is 126 μm - 5.1 mm for this electron beam momentum. The 3D Opera simulations of the THz wiggler are discussed. A new PITZ photocathode laser system is proposed for the optimized performance of the high-brightness electron beam. The main goal is a production of 3D ellipsoidal electron bunches with homogeneous charge density. The electromagnetic wiggler is supposed to be used for measuring the longitudinal shape of these electron bunches.

  14. Extraction of High Charge Electron Bunch from the ELSA RF Injector Comparison Between Simulation and Experiment

    CERN Document Server

    Lemaire, J; Binet, A; Lagniel, J M; Le Flanchec, V; Pichoff, N

    2004-01-01

    A new scheme based on a photoinjector and a RF linear accelerator operating at 352 MHz has been recently proposed as a versatile radiographic facility. Beam pulses of 60 ns duration contain 20 succesive electron bunches which will be extracted at 2.5 MeV from a photoinjector then accelerated through the next structure to the final energy of 51 MeV. Bunches carrying 100 nC are required for this purpose. As a first demonstrating step, 50 nC electron bunches have been produced and accelerated to 2.5 MeV with the 144 MHz ELSA photoinjector at Bruyères le Chatel. For this experiment, we compare the results and the numerical simulations made with PARMELA, MAGIC and MAFIA codes.

  15. Pickup design for high bandwidth bunch arrival-time monitors in free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Angelovski, Aleksandar; Penirschke, Andreas; Jakoby, Rolf [TU Darmstadt (Germany). Institut fuer Mikrowellentechnik und Photonik; Kuhl, Alexander; Schnepp, Sascha [TU Darmstadt (Germany). Graduate School of Computational Engineering; Bock, Marie Kristin; Bousonville, Michael; Schlarb, Holger [Deutsches Elektronen-Synchrotron DESY, Hamburg (Germany); Weiland, Thomas [TU Darmstadt (Germany). Institut fuer Theorie Elektromagnetischer Felder

    2012-07-01

    The increased demands for low bunch charge operation mode in the free-electron lasers (FELs) require an upgrade of the existing synchronization equipment. As a part of the laser-based synchronization system, the bunch arrival-time monitors (BAMs) should have a sub-10 femtosecond precision for high and low bunch charge operation. In order to fulfill the resolution demands for both modes of operation, the bandwidth of such a BAM should be increased up to a cutoff frequency of 40 GHz. In this talk, we present the design and the realization of high bandwidth cone-shaped pickup electrodes as a part of the BAM for the FEL in Hamburg (FLASH) and the European X-ray free-electron laser (European XFEL). The proposed pickup was simulated with CST STUDIO SUITE, and a non-hermetic model was built up for radio frequency (rf) measurements.

  16. Quasi-Monoenergetic Dense and Uniform Electron Bunch Generation from Laser Driven Double-Layer Thin Films

    Science.gov (United States)

    Wang, C.; Roycroft, R.; McCary, E.; Meadows, A.; Blakeney, J.; Serratto, K.; Kuk, D.; Chester, C.; Gao, L.; Fu, H.; Yan, X. Q.; Schreiber, J.; Pomerantz, I.; Bernstein, A.; Quevedo, H.; Dyer, G.; Gaul, E.; Ditmire, T.; Gautier, D. C.; Fernandez, J.; Hegelich, B. M.

    2014-10-01

    We demonstrate that dense, uniform quasi-monoenergetic relativistic electron bunches can be generated from the interaction of a high-intensity laser pulse with a double-layer thin film target. The first layer of the target is a freestanding, nanometer-scale, diamond-like carbon production layer. The second layer is a thin plastic reflection layer which reflects the drive-laser pulse, but allows electrons to pass through. Although no electron bunch is generated from the second layer alone, by adding it behind the first layer we obtained a quasi-monoenergetic bunch along the laser axis, 35 times denser than a bunch from the single layer target. Comparing the angular distribution of the electron spectra from a double-layer target with that of a single-layer target, we observed an increase of the electron cutoff energy at larger angles, which improves the uniformity of created electron bunches.

  17. Relativistic attosecond electron bunch emission from few-cycle laser irradiated nanoscale droplets

    Directory of Open Access Journals (Sweden)

    Laura Di Lucchio

    2015-02-01

    Full Text Available Attosecond electron bunches produced at the surface of nanometer-scale droplets illuminated by a two-cycle laser pulse are investigated for the purpose of determining their optimal emission characteristics. Significant departures from Mie theory are found for electron bunch emission from droplets whose radii satisfy the condition δ_{r}bunches is to a good approximation described by the nonlinear ponderomotive scattering model. Subsequently, the bunches are subject to further deflection by the ponderomotive pressure of the copropagating laser field in vacuum, depending on the initial droplet parameters. Final emission angles are estimated, together with the energy spectrum of the bunches.

  18. Electron Cloud Simulations of a Proton Storage Ring Using Cold Proton Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Dr Y [KEK, Tsukuba, Ibaraki, Japan; Holmes, Jeffrey A [ORNL; Lee, SY [Indiana University; Macek, R [Los Alamos National Laboratory (LANL)

    2008-01-01

    Using the ORBIT code we study the sensitivity of electron cloud properties with respect to different proton beam profiles, the secondary electron yield (SEY) parameter, and the proton loss rate. Our model uses a cold proton bunch to generate primary electrons and electromagnetic field for electron cloud dynamics. We study the dependence of the prompt and swept electron signals vs the bunch charge and the recovery of electron clouds after sweeping on the beam loss rate and the SEY. The simulation results are compared with the experimental data measured at the proton storage ring at the Los Alamos National Laboratory. Our simulations indicate that the fractional proton loss rate in the field-free straight section may be an exponential function of proton beam charge and may also be lower than the averaged fractional proton loss rate over the whole ring.

  19. Electron cloud simulations of a proton storage ring using cold proton bunches

    Directory of Open Access Journals (Sweden)

    Y. Sato

    2008-02-01

    Full Text Available Using the ORBIT code we study the sensitivity of electron cloud properties with respect to different proton beam profiles, the secondary electron yield (SEY parameter, and the proton loss rate. Our model uses a cold proton bunch to generate primary electrons and electromagnetic field for electron cloud dynamics. We study the dependence of the prompt and swept electron signals vs the bunch charge and the recovery of electron clouds after sweeping on the beam loss rate and the SEY. The simulation results are compared with the experimental data measured at the proton storage ring at the Los Alamos National Laboratory. Our simulations indicate that the fractional proton loss rate in the field-free straight section may be an exponential function of proton beam charge and may also be lower than the averaged fractional proton loss rate over the whole ring.

  20. Electron bunchlength measurement from analysis of fluctuations in spontaneous emission

    International Nuclear Information System (INIS)

    Catravas, P.; Leemans, W.P.; Wurtele, J.S.; Zolotorev, M.S.; Babzien, M.; Ben-Zvi, I.; Segalov, Z.; Wang, X.; Yakimenko, V.

    1999-01-01

    A statistical analysis of fluctuations in the spontaneous emission of a single bunch of electrons is shown to provide a new bunchlength diagnostic. This concept, originally proposed by Zolotorev and Stupakov [1], is based on the fact that shot noise from a finite bunch has a correlation length defined by the bunchlength, and therefore has a spiky spectrum. Single shot spectra of wiggler spontaneous emission have been measured at 632 nm from 44 MeV single electron bunches of 1 - 5 ps. The scaling of the spectral fluctuations with frequency resolution and the scaling of the spectral intensity distribution with bunchlength are studied. Bunchlength was extracted in a single shot measurement. Agreement was obtained between the experiment and a theoretical model, and with independent time integrated measurements. copyright 1999 American Institute of Physics

  1. Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T-2 weighted turbo spin echo techniques

    NARCIS (Netherlands)

    Coenegrachts, K.; Delanote, J.; ter Beek, L.; Haspeslagh, M.; Bipat, S.; Stoker, J.; van Kerkhove, F.; Steyaert, L.; Rigauts, H.; Casselman, J. W.

    2007-01-01

    The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b=0, b=20, b=300, b=800 s mm(-2)) and single-shot T-2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with

  2. Bunch evolution study in optimization of MeV ultrafast electron diffraction

    Science.gov (United States)

    Lu, Xian-Hai; Du, Ying-Chao; Huang, Wen-Hui; Tang, Chuan-Xiang

    2014-12-01

    Megaelectronvolt ultrafast electron diffraction (UED) is a promising detection tool for ultrafast processes. The quality of diffraction image is determined by the transverse evolution of the probe bunch. In this paper, we study the contributing terms of the emittance and space charge effects to the bunch evolution in the MeV UED scheme, employing a mean-field model with an ellipsoidal distribution as well as particle tracking simulation. The small transverse dimension of the drive laser is found to be critical to improve the reciprocal resolution, exploiting both smaller emittance and larger transverse bunch size before the solenoid. The degradation of the reciprocal spatial resolution caused by the space charge effects should be carefully controlled.

  3. Longitudinal study of group a bunch of electrons in a linear accelerator

    International Nuclear Information System (INIS)

    Ben Taghalline, Ines; Ben Khedher, Rihab

    2009-01-01

    For an effective use of the electron beam, the energy dispersion shall have to be the weakest possible on the other hand the beam intensity owes shall be the biggest possible. In the practice these parameters depended of the bunching elements in the accelerator. The first part of our work presents studies concerning the influence of the modulation tension in the cavity and the drift space length on the bunching quality. The second part of this study is related to development an algorithm dedicated to determine the RF and geometrical parameters which influence the bunching quality. The studied case is a cavity followed by a drift space. The result obtained by application this algorithm is in good agreement with the others simulations result.

  4. Short electron bunches generated by perpendicularly crossing laser pulses.

    Czech Academy of Sciences Publication Activity Database

    Horný, Vojtěch; Petržílka, Václav; Klimo, Ondřej; Krůs, Miroslav

    2017-01-01

    Roč. 24, č. 10 (2017), č. článku 103125. ISSN 1070-664X R&D Projects: GA ČR GA15-03118S; GA MŠk(CZ) LM2015083; GA MŠk(CZ) CZ.02.1.01/0.0/0.0/16_013/0001552; GA MŠk LQ1606; GA MŠk(CZ) LD14089 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:61389021 ; RVO:68378271 Keywords : Laser pulses * Particle beam bunching * Plasma simulation * Particle acceleration * Lasers * Particle-in-cell metthod * Particle beams * Electrostatics Subject RIV: BL - Plasma and Gas Discharge Physics; BL - Plasma and Gas Discharge Physics (FZU-D) OBOR OECD: Fluids and plasma physics (including surface physics); Fluids and plasma physics (including surface physics) (FZU-D) Impact factor: 2.115, year: 2016 http://aip.scitation.org/doi/10.1063/1.5007889

  5. Single-shot work extraction in quantum thermodynamics revisited

    Science.gov (United States)

    Wang, Shang-Yung

    2018-01-01

    We revisit the problem of work extraction from a system in contact with a heat bath to a work storage system, and the reverse problem of state formation from a thermal system state in single-shot quantum thermodynamics. A physically intuitive and mathematically simple approach using only elementary majorization theory and matrix analysis is developed, and a graphical interpretation of the maximum extractable work, minimum work cost of formation, and corresponding single-shot free energies is presented. This approach provides a bridge between two previous methods based respectively on the concept of thermomajorization and a comparison of subspace dimensions. In addition, a conceptual inconsistency with regard to general work extraction involving transitions between multiple energy levels of the work storage system is clarified and resolved. It is shown that an additional contribution to the maximum extractable work in those general cases should be interpreted not as work extracted from the system, but as heat transferred from the heat bath. Indeed, the additional contribution is an artifact of a work storage system (essentially a suspended ‘weight’ that can be raised or lowered) that does not truly distinguish work from heat. The result calls into question the common concept that a work storage system in quantum thermodynamics is simply the quantum version of a suspended weight in classical thermodynamics.

  6. Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera

    International Nuclear Information System (INIS)

    Uesaka, M.; Ueda, T.; Kozawa, T.; Kobayashi, T.

    1998-01-01

    Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera is presented. The subpicosecond electron single bunch of energy 35 MeV was generated by the achromatic magnetic pulse compressor at the S-band linear accelerator of nuclear engineering research laboratory (NERL), University of Tokyo. The electric charge per bunch and beam size are 0.5 nC and the horizontal and vertical beam sizes are 3.3 and 5.5 mm (full width at half maximum; FWHM), respectively. Pulse shape of the electron single bunch is measured via Cherenkov radiation emitted in air by the femtosecond streak camera. Optical parameters of the optical measurement system were optimized based on much experiment and numerical analysis in order to achieve a subpicosecond time resolution. By using the optimized optical measurement system, the subpicosecond pulse shape, its variation for the differents rf phases in the accelerating tube, the jitter of the total system and the correlation between measured streak images and calculated longitudinal phase space distributions were precisely evaluated. This measurement system is going to be utilized in several subpicosecond analyses for radiation physics and chemistry. (orig.)

  7. Emittance growth due to static and radiative space charge forces in an electron bunch compressor

    Science.gov (United States)

    Talman, Richard; Malitsky, Nikolay; Stulle, Frank

    2009-01-01

    Evolution of short intense electron bunches passing through bunch-compressing beam lines is studied using the UAL (Unified Accelerator Libraries) string space charge formulation [R. Talman, Phys. Rev. ST Accel. Beams 7, 100701 (2004)PRABFM1098-440210.1103/PhysRevSTAB.7.100701; N. Malitsky and R. Talman, in Proceedings of the 9th European Particle Accelerator Conference, Lucerne, 2004 (EPS-AG, Lucerne, 2004); R. Talman, Accelerator X-Ray Sources (Wiley-VCH, Weinheim, 2006), Chap. 13]. Three major configurations are studied, with the first most important and studied in greatest detail (because actual experimental results are available and the same results have been simulated with other codes): (i) Experimental bunch compression results were obtained at CTF-II, the CERN test facility for the “Compact Linear Collider” using electrons of about 40 MeV. Previous simulations of these results have been performed (using TraFiC4* [A. Kabel , Nucl. Instrum. Methods Phys. Res., Sect. A 455, 185 (2000)NIMAER0168-900210.1016/S0168-9002(00)00729-4] and ELEGANT [M. Borland, Argonne National Laboratory Report No. LS-287, 2000]). All three simulations are in fair agreement with the data except that the UAL simulation predicts a substantial dependence of horizontal emittance γx on beam width (as controlled by the lattice βx function) at the compressor location. This is consistent with the experimental observations, but inconsistent with other simulations. Excellent agreement concerning dependence of bunch energy loss on bunch length and magnetic field strength [L. Groening , in Proceedings of the Particle Accelerator Conference, Chicago, IL, 2001 (IEEE, New York, 2001), http://groening.home.cern/groening/csr_00.htm] confirms our understanding of the role played by coherent synchrotron radiation (CSR). (ii) A controlled comparison is made between the predictions of the UAL code and those of CSRTrack [M. Dohlus and T. Limberg, in Proceedings of the 2004 FEL Conference, pp. 18

  8. Single-shot beam profile diagnostics for x-ray FEL's using gas fluorescence

    Science.gov (United States)

    Feng, Yiping; Zhu, Diling; Weninger, Clemens; Alonso-Mori, Roberto; Chollet, Matthieu; Damiani, Daniel S.; Glownia, James M.; Hastings, Jerome B.; Nelson, Silke; Song, Sanghoon; Robert, Aymeric

    2017-06-01

    We report experimental demonstration of capturing single-shot X-ray Free-electron Laser (FEL) beam profiles using gas fluorescence. The measurement was carried out at the Linac Coherent Light Source using 7 keV hard X-rays propagating through ambient air. The nitrogen fluorescence emitted upon the passage of the X-ray FEL beam were imaged using a highly sensitive optical setup, and there was sufficient optical yield that single-shot measurements were feasible. By taking two orthogonal and simultaneous images, the beam trajectory could be determined in a nearly non-invasive manner, and is best suited for photon energies in the soft X-ray regime, where such a diagnostic capability has been largely unavailable previously. The integrated intensity of the images could also serve as a non-invasive intensity monitor, complementary to current implementations of gas- and solidbased monitors. High repetition-rate Free-electron Lasers can greatly benefit from such a new diagnostic tool for eliminating potential thermal damages.

  9. Longitudinal phase-space manipulation of ellipsoidal electron bunches in realistic fields

    Directory of Open Access Journals (Sweden)

    S. B. van der Geer

    2006-04-01

    Full Text Available Since the recent publication of a practical recipe to create “pancake” electron bunches which evolve into uniformly filled ellipsoids, a number of papers have addressed both an alternative method to create such ellipsoids as well as their behavior in realistic fields. So far, the focus has been on the possibilities to preserve the initial “thermal” transverse emittance. This paper addresses the linear longitudinal phase space of ellipsoidal bunches. It is shown that ellipsoidal bunches allow ballistic compression at subrelativistic energies, without the detrimental effects of nonlinear space-charge forces. This in turn eliminates the need for the large correlated energy spread normally required for longitudinal compression of relativistic particle beams, while simultaneously avoiding all problems related to magnetic compression. Furthermore, the linear space-charge forces of ellipsoidal bunches can be used to reduce the remaining energy spread even further, by carefully choosing the beam transverse size, in a process that is essentially the time-reversed process of the creation of an ellipsoid at the cathode. The feasibility of compression of ellipsoidal bunches is illustrated with a relatively simple setup, consisting of a half-cell S-band photogun and a two-cell booster compressor. Detailed GPT simulations in realistic fields predict that 100 pC ellipsoidal bunches can be ballistically compressed to 100 fs, at a transverse emittance of 0.7   μm, with a final energy of 3.7 MeV and an energy spread of only 50 keV.

  10. Ion response to relativistic electron bunches in the blowout regime of laser-plasma accelerators.

    Science.gov (United States)

    Popov, K I; Rozmus, W; Bychenkov, V Yu; Naseri, N; Capjack, C E; Brantov, A V

    2010-11-05

    The ion response to relativistic electron bunches in the so called bubble or blowout regime of a laser-plasma accelerator is discussed. In response to the strong fields of the accelerated electrons the ions form a central filament along the laser axis that can be compressed to densities 2 orders of magnitude higher than the initial particle density. A theory of the filament formation and a model of ion self-compression are proposed. It is also shown that in the case of a sharp rear plasma-vacuum interface the ions can be accelerated by a combination of three basic mechanisms. The long time ion evolution that results from the strong electrostatic fields of an electron bunch provides a unique diagnostic of laser-plasma accelerators.

  11. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  12. Longitudinal dynamics of RF-bunched and electron-cooled ion beam at the CSRe

    Energy Technology Data Exchange (ETDEWEB)

    Wen, W.Q. [Institute of Modern Physics, Chinese Academy of Sciences, 730000 Lanzhou (China); Ma, X., E-mail: x.ma@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, 730000 Lanzhou (China); Bussmann, M. [Helmholtz-Zentrum Dresden-Rossendorf, D-01328 Dresden (Germany); Yuan, Y.J.; Zhang, D.C. [Institute of Modern Physics, Chinese Academy of Sciences, 730000 Lanzhou (China); Winters, D.F.A [GSI Helmholtzzentrum für Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Zhu, X.L.; Li, J.; Liu, H.P.; Zhao, D.M.; Wang, Z.S.; Mao, R.S.; Zhao, T.C.; Wu, J.X.; Ma, X.M.; Yan, T.L.; Li, G.H.; Yang, X.D.; Liu, Y.; Yang, J.C. [Institute of Modern Physics, Chinese Academy of Sciences, 730000 Lanzhou (China); and others

    2014-02-01

    The longitudinal dynamics of RF-bunched and electron cooled ion beams have been studied at the experimental cooler storage ring (CSRe), at IMP Lanzhou. By RF-bunching the ion beam at the 50th and 100th harmonic of the revolution frequency, the longitudinal momentum spread and the bunch length of the {sup 22}Ne{sup 10+} ion beam with an energy of 70 MeV/u were measured by the new resonant Schottky pick-up and the capacitive pick-up, respectively. A minimum momentum spread of Δp/p=1.6×10{sup −5} has been reached with less than 10{sup 7} ions stored in the ring. By using the harmonic potential extracted from the Taylor expansion and the real sinusoidal potential of the bucket, the trend of momentum spread and synchrotron frequency as well as the bunch length as a function of beam current can be interpreted very well. According to this experiment, the RF-buncher is suitable for upcoming experiments on laser cooling of relativistic heavy ion beams at the CSRe.

  13. Spatio-temporal dynamics of relativistic electron bunches during the micro bunching instability: study of the Synchrotron Soleil and UVSOR storage rings

    International Nuclear Information System (INIS)

    Roussel, Eleonore

    2014-01-01

    Relativistic electron bunches circulating in storage rings are used to produce intense radiation from far-infrared to X-rays. However, above a density threshold value, the interaction between the electron bunch and its own radiation can lead to a spatio-temporal instability called micro bunching instability. This instability is characterized by a strong emission of coherent THz radiation (typically 105 times stronger than the classical synchrotron radiation) which is a signature of the presence of microstructures (at mm scale) in the electron bunch. This instability is known to be a fundamental limitation of the operation of synchrotron light sources at high beam current. In this thesis, we have focused on this instability from a nonlinear dynamics point of view by combining experimental studies carried out at the Synchrotron Soleil and UVSOR storage rings with numerical studies mainly based on the Vlasov-Fokker-Planck equation. In a first step, due to the very indirect nature of the experimental observations, we have sought to deduce information on the microstructure wavenumber either by looking at the temporal evolution of the THz signal emitted during the instability or by studying the response of the electron bunch to a laser perturbation. In a second step, we have achieved direct, real time observations of the microstructures dynamics through two new, very different, detection techniques: a thin-film superconductor-based detector at UVSOR, and a spectrally-encoded electro-optic detection technique at Soleil. These new available experimental observations have allowed severe comparisons with the theoretical models. (author)

  14. Production of high intensity electron bunches for the SLAC Linear Collider

    International Nuclear Information System (INIS)

    James, M.B.

    1987-08-01

    This thesis describes the design and performance of a high intensity electron injecfor for the SLAC Linear Collider. Motivation for the collider and the specifications for the injector are discussed. An analytic theory of the bunching and capture of electrons by rf fields is discussed in the limit of low space charge and small signal. The design and performance of SLAC's main injector are described to illustrate a successful application of this theory. The bunching and capture of electrons by rf fields are then discussed in the limit of high space charge and large signal, and a description of the design of the collider injector follows. In the limit of high space charge forces and large rf signals, the beam dynamics are considerably more complex and numerical simulations are required to predict particle motion. A computer code which models the longitudinal dynamics of electrons in the presence of space charge and rf fields is described. The results of the simulations, the resulting collider injector design and the various components which make up the collider injector are described. These include the gun, subharmonic bunchers, traveling-wave buncher and velocity-of-light accelerator section. Finally, the performance of the injector is described including the beam intensity, bunch length, transverse emittance and energy spectrum. While the final operating conditions differ somewaht from the design, the performance of the collider injector is in good agreement with the numerical simulations and meets all of the collider specifications. 28 refs

  15. Electro-optic techniques in electron beam diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    van Tilborg, Jeroen; Toth, Csaba; Matlis, Nicholas; Plateau, Guillaume; Leemans, Wim

    2011-06-17

    Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

  16. Determination of Longitudinal Electron Bunch Lengths on Picosecond Time Scales

    CERN Document Server

    Martínez, C; Calviño, F

    1999-01-01

    At CERN (European Laboratory for Particle Physics) the CLIC (Compact Linear Collider) study is pursuing the design of an electron-positron high-energy linear collider using an innovative concept for the RF (Radio Frequency) power production, the socalled two-beam acceleration scheme. In order to keep the length of the collider in a reasonable range while being able of accelerating electrons and positrons up to 5 TeV, the normal-conducting accelerating structures should operate at very high frequency (in this case 30 GHz). The RF power necessary to feed the accelerating cavities is provided by a second electron beam, the drive beam, running parallel to the main beam. The CLIC Test Facility (CTF) was build with the main aim of studying and demonstrating the feasibility of the two beam acceleration scheme and technology. It is composed of two beams, the drive beam that will generate the 30 GHz RF power and the main beam which will be accelerated by this power. In order to have a good efficiency for the power gen...

  17. MITIGATION OF THE ELECTRON-CLOUD EFFECT IN THE PSR AND SNS PROTONSTORAGE RINGS BY TAILORING THE BUNCH PROFILE

    International Nuclear Information System (INIS)

    Pivi, Mauro T F

    2003-01-01

    For the storage ring of the Spallation Neutron Source (SNS) at Oak Ridge, and for the Proton Storage Ring (PSR) at Los Alamos, both with intense and very long bunches, the electron cloud develops primarily by the mechanism of trailing-edge multipacting. We show, by means of simulations for the PSR, how the resonant nature of this mechanism may be effectively broken by tailoring the longitudinal bunch profile at fixed bunch charge, resulting in a significant decrease in the electron-cloud effect. We briefly discuss the experimental difficulties expected in the implementation of this cure

  18. Mitigation of the electron-cloud effect in the PSR and SNS protonstorage rings by tailoring the bunch profile

    CERN Document Server

    Pivi, M T

    2003-01-01

    For the storage ring of the Spallation Neutron Source (SNS) at Oak Ridge, and for the Proton Storage Ring (PSR) at Los Alamos, both with intense and very long bunches, the electron cloud develops primarily by the mechanism of trailing-edge multipacting. We show, by means of simulations for the PSR, how the resonant nature of this mechanism may be effectively broken by tailoring the longitudinal bunch profile at fixed bunch charge, resulting in a significant decrease in the electron-cloud effect. We briefly discuss the experimental difficulties expected in the implementation of this cure.

  19. Emittance growth due to static and radiative space charge forces in an electron bunch compressor

    CERN Document Server

    Talman, Richard; Stulle, Frank

    2009-01-01

    Evolution of short intense electron bunches passing through bunch-compressing beam lines is studied using the UAL (Unified Accelerator Libraries) string space charge formulation [R. Talman, Phys. Rev. ST Accel. Beams 7, 100701 (2004); N. Malitsky and R. Talman, in Proceedings of the 9th European Particle Accelerator Conference, Lucerne, 2004 (EPS-AG, Lucerne, 2004); R. Talman, Accelerator X-Ray Sources (Wiley-VCH, Weinheim, 2006), Chap. 13]. Three major configurations are studied, with the first most important and studied in greatest detail (because actual experimental results are available and the same results have been simulated with other codes): (i) Experimental bunch compression results were obtained at CTF-II, the CERN test facility for the “Compact Linear Collider” using electrons of about 40 MeV. Previous simulations of these results have been performed (using trafic4* [A. Kabel et al., Nucl. Instrum. Methods Phys. Res., Sect. A 455, 185 (2000)] and elegant [M. Borland, Argonne National Laboratory...

  20. Microwave measurements of energy lost to longitudinal modes by single electron bunches traversing periodic structures

    International Nuclear Information System (INIS)

    Wang, J.W.; Loew, G.A.; Weaver, J.N.; Wilson, P.B.

    1981-10-01

    In the design of future linear colliders, it will be important to minimize the loss of beam energy due to the excitation of higher-order modes in the accelerator structure by single bunches of electrons or positrons. This loss is not only detrimental in itself but also gives rise to energy spectrum widening and transverse emittance growth. Microwave measurements made on disk-loaded and alternating-spoke structures to determine the loss to the longitudinal modes are described. In these measurements the Gaussian bunch is simulated by a current pulse of the same shape transmitted through the structure on an axial center conductor. Results to date are presented for the total longitudinal loss parameter per period K in volts per picocoulomb

  1. Feedback for suppression of single-bunch transverse instability in electron-positron storage rings

    International Nuclear Information System (INIS)

    Smaluk, V; Sukhanov, D; Oreshonok, V; Cherepanov, V; Kiselev, V

    2012-01-01

    Transverse head-tail instability is a severe limitation of a single-bunch beam current in circular accelerators. Applicability and efficiency of feedbacks for suppression of the instability is analyzed. Both chromatic and nonlinear effects have been taken into account to understand the processes of excitation and damping of the instability. Analytical estimations are compared with the results of experiments and numerical simulations. A feedback system has been developed, installed and commissioned at the VEPP-4M electron-positron collider. An original scheme of the kicker powering has been developed to provide the necessary performance with minimal expenses. Real-time digital data processing performed by a code running in an FPGA module provides high efficiency and flexibility of the system. During the system commissioning, a more than threefold increase of intensity of the VEPP-4M single-bunch beam has been achieved.

  2. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  3. Can coherent Smith-Purcell radiation be used to determine the shape of an electron bunch?

    International Nuclear Information System (INIS)

    Doria, A.; Gallerano, G.P.; Giovenale, E.; Messina, G.; Doucas, G.; Kimmitt, M.F.; Andrews, H.L.; Brownell, J.H.

    2002-01-01

    Recent measurements at Frascati of the Smith-Purcell radiation emitted from the interaction of a 2.3 MeV (total) electron beam with a 2.5 mm grating show clear evidence of coherent enhancement of the radiation, with power levels exceeding 100 mW at emission angles around 90 deg. relative to the beam direction. The experimental results are in reasonable agreement with theoretical predictions and suggest that Smith-Purcell radiation may offer a simple way of determining the shape and duration of short (picosecond) electron bunches

  4. Probing plasma wakefields using electron bunches generated from a laser wakefield accelerator

    Science.gov (United States)

    Zhang, C. J.; Wan, Y.; Guo, B.; Hua, J. F.; Pai, C.-H.; Li, F.; Zhang, J.; Ma, Y.; Wu, Y. P.; Xu, X. L.; Mori, W. B.; Chu, H.-H.; Wang, J.; Lu, W.; Joshi, C.

    2018-04-01

    We show experimental results of probing the electric field structure of plasma wakes by using femtosecond relativistic electron bunches generated from a laser wakefield accelerator. Snapshots of laser-driven linear wakes in plasmas with different densities and density gradients are captured. The spatiotemporal evolution of the wake in a plasma density up-ramp is recorded. Two parallel wakes driven by a laser with a main spot and sidelobes are identified in the experiment and reproduced in simulations. The capability of this new method for capturing the electron- and positron-driven wakes is also shown via 3D particle-in-cell simulations.

  5. Propagation of attosecond electron bunches along the cone-and-channel target

    International Nuclear Information System (INIS)

    Yang, X. H.; Shao, F. Q.; Yin, Y.; Tian, C. L.; Xu, H.; Ma, Y. Y.; Zhuo, H. B.; Yu, M. Y.

    2011-01-01

    Generation and propagation of attosecond electron bunches along a cone-and-channel target are investigated by particle-in-cell simulation. The target electrons are pulled out by the oscillating electric field of an intense laser pulse irradiating a cone target and accelerated forward along the cone walls. It is shown that the energetic electrons can be further guided and confined by a channel attached to the cone tip. The propagation of these electrons along the channel induces a strong quasistatic magnetic field as well as a sheath electric field since a part of the energetic electrons expands into the surrounding vacuum. The electromagnetic field in turn confines the surface currents. With the cone-and-channel target the energetic electrons can be much better collimated and propagate much farther than that from the classical cone target.

  6. Mitigation of the electron-cloud effect in the PSR and SNS proton storage rings by tailoring the bunch profile

    International Nuclear Information System (INIS)

    Pivi, M.; Furman, M.A.

    2003-01-01

    For the storage ring of the Spallation Neutron Source(SNS) at Oak Ridge, and for the Proton Storage Ring (PSR) at Los Alamos, both with intense and very long bunches, the electroncloud develops primarily by the mechanism of trailing-edge multipacting. We show, by means of simulations for the PSR, how the resonant nature of this mechanism may be effectively broken by tailoring the longitudinal bunch profile at fixed bunch charge, resulting in a significant decrease in the electron-cloud effect. We briefly discuss the experimental difficulties expected in the implementation of this cure

  7. Observation of coherently enhanced tunable narrow-band terahertz transition radiation from a relativistic sub-picosecond electron bunch train

    International Nuclear Information System (INIS)

    Piot, P.; Maxwell, T. J.; Sun, Y.-E; Ruan, J.; Lumpkin, A. H.; Thurman-Keup, R.; Rihaoui, M. M.

    2011-01-01

    We experimentally demonstrate the production of narrow-band (δf/f≅20% at f≅0.5THz) transition radiation with tunable frequency over [0.37, 0.86] THz. The radiation is produced as a train of sub-picosecond relativistic electron bunches transits at the vacuum-aluminum interface of an aluminum converter screen. The bunch train is generated via a transverse-to-longitudinal phase space exchange technique. We also show a possible application of modulated beams to extend the dynamical range of a popular bunch length diagnostic technique based on the spectral analysis of coherent radiation.

  8. Mitigation of the electron-cloud effect in the PSR and SNS proton storage rings by tailoring the bunch profile

    Energy Technology Data Exchange (ETDEWEB)

    Pivi, M.; Furman, M.A.

    2003-05-20

    For the storage ring of the Spallation Neutron Source(SNS) at Oak Ridge, and for the Proton Storage Ring (PSR) at Los Alamos, both with intense and very long bunches, the electroncloud develops primarily by the mechanism of trailing-edge multipacting. We show, by means of simulations for the PSR, how the resonant nature of this mechanism may be effectively broken by tailoring the longitudinal bunch profile at fixed bunch charge, resulting in a significant decrease in the electron-cloud effect. We briefly discuss the experimental difficulties expected in the implementation of this cure.

  9. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    Directory of Open Access Journals (Sweden)

    Jifei Zhao

    2016-06-01

    Full Text Available As an important electron source, Micro-Pulse electron Gun (MPG which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR, Free Electron Laser (FEL. The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

  10. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  11. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  12. Emittance growth due to static and radiative space charge forces in an electron bunch compressor

    Directory of Open Access Journals (Sweden)

    Richard Talman

    2009-01-01

    Full Text Available Evolution of short intense electron bunches passing through bunch-compressing beam lines is studied using the UAL (Unified Accelerator Libraries string space charge formulation [R. Talman, Phys. Rev. ST Accel. Beams 7, 100701 (2004PRABFM1098-440210.1103/PhysRevSTAB.7.100701; N. Malitsky and R. Talman, in Proceedings of the 9th European Particle Accelerator Conference, Lucerne, 2004 (EPS-AG, Lucerne, 2004; R. Talman, Accelerator X-Ray Sources (Wiley-VCH, Weinheim, 2006, Chap. 13]. Three major configurations are studied, with the first most important and studied in greatest detail (because actual experimental results are available and the same results have been simulated with other codes: (i Experimental bunch compression results were obtained at CTF-II, the CERN test facility for the “Compact Linear Collider” using electrons of about 40 MeV. Previous simulations of these results have been performed (using TraFiC4* [A. Kabel et al., Nucl. Instrum. Methods Phys. Res., Sect. A 455, 185 (2000NIMAER0168-900210.1016/S0168-9002(0000729-4] and ELEGANT [M. Borland, Argonne National Laboratory Report No. LS-287, 2000]. All three simulations are in fair agreement with the data except that the UAL simulation predicts a substantial dependence of horizontal emittance ϵ_{x} on beam width (as controlled by the lattice β_{x} function at the compressor location. This is consistent with the experimental observations, but inconsistent with other simulations. Excellent agreement concerning dependence of bunch energy loss on bunch length and magnetic field strength [L. Groening et al., in Proceedings of the Particle Accelerator Conference, Chicago, IL, 2001 (IEEE, New York, 2001, http://groening.home.cern/groening/csr_00.htm] confirms our understanding of the role played by coherent synchrotron radiation (CSR. (ii A controlled comparison is made between the predictions of the UAL code and those of CSRTrack [M. Dohlus and T. Limberg, in Proceedings of the

  13. Cold optical injection producing monoenergetic, multi-GeV electron bunches.

    Science.gov (United States)

    Davoine, X; Lefebvre, E; Rechatin, C; Faure, J; Malka, V

    2009-02-13

    A cold optical injection mechanism for a laser-plasma accelerator is described. It relies on a short, circularly polarized, low-energy laser pulse counterpropagating to and colliding with a circularly polarized main pulse in a low density plasma. Contrary to previously published optical injection schemes, injection is not caused here by electron heating. Instead, the collision between the pulses creates a spatially periodic and time-independent beat force. This force can block the longitudinal electron motion, leading to their entry and injection into the propagating wake. In a specific setup, we compute after acceleration over 0.6 mm, a 60 MeV, 50 pC electron bunch with 0.7 MeV rms energy spread, proving the interest of this scheme to inject electron bunches with a narrow absolute energy spread. Acceleration to 3 GeV with a rms spread smaller than 1% is computed after propagation over 3.8 cm in a plasma channel.

  14. Measurements of the longitudinal wakefields in a multimode, dielectric wakefield accelerator driven by a train of electron bunches

    Directory of Open Access Journals (Sweden)

    J. G. Power

    2000-10-01

    Full Text Available We report on the experimental demonstration of a novel wakefield acceleration technique where a short electron bunch excites a broadband harmonic frequency spectrum, in a cylindrical dielectric structure, to synthesize an accelerating waveform. The structure is designed to have its TM_{0n} modes nearly equally spaced so that the modes generated by a single short electron bunch constructively interfere in the neighborhood of integral multiples of the fundamental wavelength producing large acceleration gradients. Realization of a harmonic multimode structure requires more stringent design considerations than a single-mode structure, since the permittivity and loss tangent of the material should not change substantially over the bandwidth of the structure. In this experiment, a bunch train of four 5 nC electron bunches, separated by 760 ps (one net wavelength, were passed through a 60 cm long dielectric-lined cylindrical harmonic structure. Use of a train of drive bunches spaced by one wavelength reinforced the accelerating wakefield; observation of the energy loss of each bunch via a magnetic spectrometer served as a diagnostic of the wakefield. The measured energy spectrum of the four beams after passing through the waveguide was found to be in excellent agreement with the predictions of the analytic model. This result demonstrates that a dielectric can be fabricated which can synthesize the required wakefield. We also discuss potential advantages of this harmonic approach over conventional single-mode wakefield accelerators.

  15. Single-Bunch Instability Driven by the Electron Cloud Effect in the Positron Damping Ring of the International Linear Collider

    International Nuclear Information System (INIS)

    Pivi, Mauro; Raubenheimer, Tor O.; Ghalam, Ali; Harkay, Katherine; Ohmi, Kazuhito; Wanzenberg, Rainer; Wolski, Andrzej; Zimmermann, Frank

    2005-01-01

    Collective instabilities caused by the formation of an electron cloud (EC) are a potential limitation to the performances of the damping rings for a future linear collider. In this paper, we present recent simulation results for the electron cloud build-up in damping rings of different circumferences and discuss the single-bunch instabilities driven by the electron cloud

  16. Rf stability, control and bunch lengthening in electron synchrotron storage rings

    International Nuclear Information System (INIS)

    Wachtel, J.M.

    1989-09-01

    A self-consistent theory for nonlinear longitudinal particle motion and rf cavity excitation in a high energy electron storage ring is developed. Coupled first order equations for the motion of an arbitrary number of particles and for the field in several rf cavities are given in the form used in control system theory. Stochastic quantum excitation of synchrotron motion is included, as are the effects of rf control system corrections. Results of computations for double cavity bunch lengthening are given. 11 refs., 4 figs., 1 tab

  17. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  18. Experimental demonstration of fresh bunch self-seeding in an X-ray free electron laser

    International Nuclear Information System (INIS)

    Emma, C.; Lutman, A.; Guetg, M. W.; Krzywinski, J.; Marinelli, A.

    2017-01-01

    Here, we report the generation of ultrahigh brightness X-ray pulses using the Fresh Bunch Self-Seeding (FBSS) method in an X-ray Free Electron Laser (XFEL). The FBSS method uses two different electron slices or bunches, one to generate the seed and the other to amplify it after the monochromator. This method circumvents the trade-off between the seed power and electron slice energy spread, which limits the efficiency of regular self-seeded FELs. The experiment, the performance of which is limited by existing hardware, shows FBSS feasibility, generating 5.5 keV photon pulses which are 9 fs long and of 7.3 ×10 –5 bandwidth and 50 GW power. FBSS performance is compared with Self Amplified Spontaneous Emission/self-seeding performance, measuring a brightness increase of twelve/two times, respectively. In an optimized XFEL, FBSS can increase the peak power a hundred times more than state-of-the-art to multi-TW, opening new research areas for nonlinear science and single molecule imaging.

  19. Monochromatic coherent transition and diffraction radiation from a relativistic electron bunch train

    Science.gov (United States)

    Naumenko, G.; Potylitsyn, A.; Shevelev, M.; Karataev, P.; Shipulya, M.; Bleko, V.

    2018-04-01

    Electron beams of most accelerators have a bunched structure and are synchronized with the accelerating RF field. Due to modulation of the electron beam with frequency ν RF one can expect to observe resonances with frequencies ν k=kṡ ν RF in radiation spectrum generated via any spontaneous emission mechanism (k is an integer and the resonance order). In this paper we present the results of spectral measurements of coherent transition radiation (CTR) generated by an electron bunch train from the Tomsk microtron with ν RF=2.63GHz in the spectral frequency range from 8 to 35 GHz. We also measured the spectrum of coherent diffraction radiation and demonstrated that the observed spectra in both cases consist of monochromatic lines. For spectral measurements the Martin-Puplett interferometer with spectral resolution of 800 MHz (FWMH) was employed. Using a waveguide frequency cut-off we were able to exclude several spectral lines to observe higher resonance orders of up to k =7.

  20. Femtosecond timing-jitter between photo-cathode laser and ultra-short electron bunches by means of hybrid compression

    CERN Document Server

    Pompili, Riccardo; Bellaveglia, M; Biagioni, A; Castorina, G; Chiadroni, E; Cianchi, A; Croia, M; Di Giovenale, D; Ferrario, M; Filippi, F; Gallo, A; Gatti, G; Giorgianni, F; Giribono, A; Li, W; Lupi, S; Mostacci, A; Petrarca, M; Piersanti, L; Di Pirro, G; Romeo, S; Scifo, J; Shpakov, V; Vaccarezza, C; Villa, F

    2017-01-01

    The generation of ultra-short electron bunches with ultra-low timing-jitter relative to the photo-cathode (PC) laser has been experimentally proved for the first time at the SPARC_LAB test-facility (INFN-LNF, Frascati) exploiting a two-stage hybrid compression scheme. The first stage employs RF-based compression (velocity-bunching), which shortens the bunch and imprints an energy chirp on it. The second stage is performed in a non-isochronous dogleg line, where the compression is completed resulting in a final bunch duration below 90 fs (rms). At the same time, the beam arrival timing-jitter with respect to the PC laser has been measured to be lower than 20 fs (rms). The reported results have been validated with numerical simulations.

  1. A novel approach to electron data background treatment in an online wide-angle spectrometer for laser-accelerated ion and electron bunches

    Science.gov (United States)

    Lindner, F. H.; Bin, J. H.; Englbrecht, F.; Haffa, D.; Bolton, P. R.; Gao, Y.; Hartmann, J.; Hilz, P.; Kreuzer, C.; Ostermayr, T. M.; Rösch, T. F.; Speicher, M.; Parodi, K.; Thirolf, P. G.; Schreiber, J.

    2018-01-01

    Laser-based ion acceleration is driven by electrical fields emerging when target electrons absorb laser energy and consecutively leave the target material. A direct correlation between these electrons and the accelerated ions is thus to be expected and predicted by theoretical models. We report on a modified wide-angle spectrometer, allowing the simultaneous characterization of angularly resolved energy distributions of both ions and electrons. Equipped with online pixel detectors, the RadEye1 detectors, the investigation of this correlation gets attainable on a single shot basis. In addition to first insights, we present a novel approach for reliably extracting the primary electron energy distribution from the interfering secondary radiation background. This proves vitally important for quantitative extraction of average electron energies (temperatures) and emitted total charge.

  2. Femtosecond Single-Shot Imaging of Nanoscale Ferromagnetic Order in Co/Pd Multilayers using Resonant X-ray Holography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tianhan; Zhu, Diling; Benny Wu,; Graves, Catherine; Schaffert, Stefan; Rander, Torbjorn; Muller, leonard; Vodungbo, Boris; Baumier, Cedric; Bernstein, David P.; Brauer, Bjorn; Cros, Vincent; Jong, Sanne de; Delaunay, Renaud; Fognini, Andreas; Kukreja, Roopali; Lee, Sooheyong; Lopez-Flores, Victor; Mohanty, Jyoti; Pfau, Bastian; Popescu, 5 Horia

    2012-05-15

    We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm{sup 2}. Employing resonant spatially-muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm{sup 2}. Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

  3. Observation of Quantum Jumps of a Single Quantum Dot Spin Using Submicrosecond Single-Shot Optical Readout

    Science.gov (United States)

    Delteil, Aymeric; Gao, Wei-bo; Fallahi, Parisa; Miguel-Sanchez, Javier; Imamoǧlu, Atac

    2014-03-01

    Single-shot readout of individual qubits is typically the slowest process among the elementary single- and two-qubit operations required for quantum information processing. Here, we use resonance fluorescence from a single-electron charged quantum dot to read out the spin-qubit state in 800 nanoseconds with a fidelity exceeding 80%. Observation of the spin evolution on longer time scales reveals quantum jumps of the spin state: we use the experimentally determined waiting-time distribution to characterize the quantum jumps.

  4. Measurements and analysis of a high-brightness electron beam collimated in a magnetic bunch compressor

    Science.gov (United States)

    Zhou, F.; Bane, K.; Ding, Y.; Huang, Z.; Loos, H.; Raubenheimer, T.

    2015-05-01

    A collimator located in a magnetic bunch compressor of a linear accelerator driven x-ray free electron laser has many potential applications, such as the removal of horns in the current distribution, the generation of ultrashort beams, and as a diagnostic of the beam slice emittance. Collective effects, however, are a major concern in applying the technique. Systematic measurements of emittance and analysis were performed using a collimator in the first bunch compressor of the Linac Coherent Light Source (LCLS). In the nominal, undercompressed configuration using the collimator we find that the y emittance (nonbending plane) is not increased, and the x emittance (in the bending plane) is increased by about 25%, in comparison to the injector emittance. From the analysis we conclude that the parasitic effects associated with this method are dominated by coherent synchrotron radiation (CSR), which causes a "systematic error" for measuring slice emittance at the bending plane using the collimation method. In general, we find good agreement between the measurements and simulations including CSR. However, for overcompressed beams at smaller collimator gaps, an extra emittance increase is found that does not agree with 1D simulations and is not understood.

  5. Production of high-quality electron bunches by dephasing and beam loading in channeled and unchanneled laser plasma accelerators

    International Nuclear Information System (INIS)

    Geddes, C.G.R.; Toth, Cs.; Tilborg, J. van; Esarey, E.; Schroeder, C.B.; Bruhwiler, D.; Nieter, C.; Cary, J.; Leemans, W.P.

    2005-01-01

    High-quality electron beams, with a few 10 9 electrons within a few percent of the same energy above 80 MeV, were produced in a laser wakefield accelerator by matching the acceleration length to the length over which electrons were accelerated and outran (dephased from) the wake. A plasma channel guided the drive laser over long distances, resulting in production of the high-energy, high-quality beams. Unchanneled experiments varying the length of the target plasma indicated that the high-quality bunches are produced near the dephasing length and demonstrated that channel guiding was more stable and efficient than relativistic self-guiding. Consistent with these data, particle-in-cell simulations indicate production of high-quality electron beams when trapping of an initial bunch of electrons suppresses further injection by loading the wake. The injected electron bunch is then compressed in energy by dephasing, when the front of the bunch begins to decelerate while the tail is still accelerated

  6. Time domain numerical calculations of the short electron bunch wakefields in resistive structures

    International Nuclear Information System (INIS)

    Tsakanian, Andranik

    2010-10-01

    The acceleration of electron bunches with very small longitudinal and transverse phase space volume is one of the most actual challenges for the future International Linear Collider and high brightness X-Ray Free Electron Lasers. The exact knowledge on the wake fields generated by the ultra-short electron bunches during its interaction with surrounding structures is a very important issue to prevent the beam quality degradation and to optimize the facility performance. The high accuracy time domain numerical calculations play the decisive role in correct evaluation of the wake fields in advanced accelerators. The thesis is devoted to the development of a new longitudinally dispersion-free 3D hybrid numerical scheme in time domain for wake field calculation of ultra short bunches in structures with walls of finite conductivity. The basic approaches used in the thesis to solve the problem are the following. For materials with high but finite conductivity the model of the plane wave reflection from a conducting half-space is used. It is shown that in the conductive half-space the field components perpendicular to the interface can be neglected. The electric tangential component on the surface contributes to the tangential magnetic field in the lossless area just before the boundary layer. For high conducting media, the task is reduced to 1D electromagnetic problem in metal and the so-called 1D conducting line model can be applied instead of a full 3D space description. Further, a TE/TM (''transverse electric - transverse magnetic'') splitting implicit numerical scheme along with 1D conducting line model is applied to develop a new longitudinally dispersion-free hybrid numerical scheme in the time domain. The stability of the new hybrid numerical scheme in vacuum, conductor and bound cell is studied. The convergence of the new scheme is analyzed by comparison with the well-known analytical solutions. The wakefield calculations for a number of structures are performed

  7. Time domain numerical calculations of the short electron bunch wakefields in resistive structures

    Energy Technology Data Exchange (ETDEWEB)

    Tsakanian, Andranik

    2010-10-15

    The acceleration of electron bunches with very small longitudinal and transverse phase space volume is one of the most actual challenges for the future International Linear Collider and high brightness X-Ray Free Electron Lasers. The exact knowledge on the wake fields generated by the ultra-short electron bunches during its interaction with surrounding structures is a very important issue to prevent the beam quality degradation and to optimize the facility performance. The high accuracy time domain numerical calculations play the decisive role in correct evaluation of the wake fields in advanced accelerators. The thesis is devoted to the development of a new longitudinally dispersion-free 3D hybrid numerical scheme in time domain for wake field calculation of ultra short bunches in structures with walls of finite conductivity. The basic approaches used in the thesis to solve the problem are the following. For materials with high but finite conductivity the model of the plane wave reflection from a conducting half-space is used. It is shown that in the conductive half-space the field components perpendicular to the interface can be neglected. The electric tangential component on the surface contributes to the tangential magnetic field in the lossless area just before the boundary layer. For high conducting media, the task is reduced to 1D electromagnetic problem in metal and the so-called 1D conducting line model can be applied instead of a full 3D space description. Further, a TE/TM (''transverse electric - transverse magnetic'') splitting implicit numerical scheme along with 1D conducting line model is applied to develop a new longitudinally dispersion-free hybrid numerical scheme in the time domain. The stability of the new hybrid numerical scheme in vacuum, conductor and bound cell is studied. The convergence of the new scheme is analyzed by comparison with the well-known analytical solutions. The wakefield calculations for a number of

  8. Single-shot readout of multiple nuclear spin qubits in diamond under ambient conditions

    Science.gov (United States)

    Jacques, Vincent

    2013-03-01

    Nuclear spins are attractive candidates for solid-state quantum information storage and processing owing to their extremely long coherence time. However, since this appealing property results from a high level of isolation from the environment, it remains a challenging task to polarize, manipulate and readout with high fidelity individual nuclear spins. A promising approach to overcome this limitation consists in utilizing an ancillary single electronic spin to detect and control remote nuclear spins coupled by hyperfine interaction. In this talk, I will show how the electronic spin of a single Nitrogen-Vacancy (NV) defect in diamond can be used as a robust platform to observe the real-time evolution of surrounding single nuclear spins under ambient conditions. Using a diamond sample with a natural abundance of 13C isotopes, we first demonstrate high fidelity initialization and single-shot readout of an individual 13C nuclear spin. By including the intrinsic 14N nuclear spin of the NV defect in the quantum register, we then report the simultaneous observation of quantum jumps linked to both nuclear spin species, providing an efficient initialization of the two qubits. These results open up new avenues for diamond-based quantum information processing (QIP) including active feedback in quantum error correction protocols and tests of quantum correlations with solid-state single spins at room temperature.

  9. Single shot, double differential spectral measurements of inverse Compton scattering in the nonlinear regime

    Directory of Open Access Journals (Sweden)

    Y. Sakai

    2017-06-01

    Full Text Available Inverse Compton scattering (ICS is a unique mechanism for producing fast pulses—picosecond and below—of bright photons, ranging from x to γ rays. These nominally narrow spectral bandwidth electromagnetic radiation pulses are efficiently produced in the interaction between intense, well-focused electron and laser beams. The spectral characteristics of such sources are affected by many experimental parameters, with intense laser effects often dominant. A laser field capable of inducing relativistic oscillatory motion may give rise to harmonic generation and, importantly for the present work, nonlinear redshifting, both of which dilute the spectral brightness of the radiation. As the applications enabled by this source often depend sensitively on its spectra, it is critical to resolve the details of the wavelength and angular distribution obtained from ICS collisions. With this motivation, we present an experimental study that greatly improves on previous spectral measurement methods based on x-ray K-edge filters, by implementing a multilayer bent-crystal x-ray spectrometer. In tandem with a collimating slit, this method reveals a projection of the double differential angular-wavelength spectrum of the ICS radiation in a single shot. The measurements enabled by this diagnostic illustrate the combined off-axis and nonlinear-field-induced redshifting in the ICS emission process. The spectra obtained illustrate in detail the strength of the normalized laser vector potential, and provide a nondestructive measure of the temporal and spatial electron-laser beam overlap.

  10. Emittance evolution of a tightly focused electron bunch with high energy spread

    CERN Document Server

    Rossi, A R

    2011-01-01

    The production of a self injected high energy electron beam from laser-plasma interaction is one of the goals at the LI2FE infrastructure at LNF. The formation and acceleration of a beam produced with the experimental setting available in Frascati has been simulated by C. Benedetti et al. by means of the code AlaDyn [1]; the results, shown in Figure 1, foresee that the bunch should have a total charge of about 3.5 nC, a transverse size of few microns and a very broad spectrum, ranging from a few MeV up to about 1 GeV, in agreement with other numerical and experimental results produced world wide. In particular, a neatly separated charge portion at high energy is present (Figure 2), whose main parameters are reported in Table 1, which constitutes the most interesting product of the plasma based accelerator.

  11. Emission of ultrashort electromagnetic pulses from electron bunches formed and accelerated by laser beams with tilted amplitude fronts

    International Nuclear Information System (INIS)

    Galkin, A.L.; Korobkin, V.V.; Romanovsky, M.Yu.; Shiryaev, O.B.; Trofimov, V.A.

    2013-01-01

    The dynamics of an electron in a standing wave generated by a pair of counterpropagating linearly polarized relativistically intense laser pulses and the emission of electromagnetic radiation by the electron are analyzed. The pulses are assumed to have tilted amplitude fronts and asymmetric focal spots. The analysis of the dynamics is performed by solving numerically the Newton equation with the corresponding Lorentz force, and the emission of radiation is simulated based on the Lienard-Wiechert potentials. The electrons are accelerated by the direct action of the standing wave field and are shown to form a small short bunch. For relativistic intensities, the energies gained by the electrons reach several GeV. It is demonstrated that the radiation emitted by the electrons in the bunch is a single electromagnetic pulse confined to a narrow solid angle and having an attosecond duration. (copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  12. Oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend-electron beam irradiation

    International Nuclear Information System (INIS)

    Ratnam, Chantara Thevy; Raju, Gunasunderi; Wan Md Zin Wan Yunus

    2007-01-01

    The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeV electron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies revealed that grafting of the OPEFB fiber with methyl acrylate did not cause appreciable effect to the tensile properties and gel fraction of the composites upon irradiation. The morphology of fractured surfaces of the composites, examined by a scanning electron microscope showed an improvement in the adhesion between the fiber and the matrix was achieved upon grafting of the fiber with methyl acrylate

  13. Much Ado about Microbunching: Coherent Bunching in High Brightness Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Ratner, Daniel [Stanford Univ., CA (United States)

    2011-05-01

    The push to provide ever brighter coherent radiation sources has led to the creation of correspondingly bright electron beams. With billions of electrons packed into normalized emittances (phase space) below one micron, collective effects may dominate both the preservation and use of such ultra-bright beams. An important class of collective effects is due to density modulations within the bunch, or microbunching. Microbunching may be deleterious, as in the case of the Microbunching Instability (MBI), or it may drive radiation sources of unprecedented intensity, as in the case of Free Electron Lasers (FELs). In this work we begin by describing models of microbunching due to inherent beam shot noise, which sparks both the MBI as well as SLAC's Linac Coherent Light Source, the world's first hard X-ray laser. We first use this model to propose a mechanism for reducing the inherent beam shot noise as well as for predicting MBI effects. We then describe experimental measurements of the resulting microbunching at LCLS, including optical radiation from the MBI, as well as the first gain length and harmonic measurements from a hard X-ray FEL. In the final chapters, we describe schemes that use external laser modulations to microbunch light sources of the future. In these sections we describe coherent light source schemes for both both linacs and storage rings.

  14. Study on interference between far-IR to mm-wave CSR from consecutive electron bunches at BFEL RF-Linac

    CERN Document Server

    Biao, Z J; Xie Jia Li; Zhang Guo Qing

    2001-01-01

    Coherent bending magnet or undulator radiation due to a train of electron bunches is treated as radiation from a multi-slit diffraction array. Based on this model, we numerically analyse the interference among coherent synchrotron radiation emitted from consecutive bunches in a train of bunches, which are accelerated by a 30-MeV RF-linac at BFEL. Some interesting results are as follows: (1) Rapidly oscillating radiation enhancement due to interbunch interference is overlapped on the single bunch spectrum. (2) It consists of a series of spectrum lines corresponding to harmonics of the RF fundamental. (3) Main maximum positions are determined by the 'diffraction condition'. (4) Total intensity is about the square of the number of bunches participating in interference as single bunch intensity. Experimental design to measure interbunch interference at BFEL with the sub-mm and mm-wave Michelson interferometer is presented.

  15. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  16. The Effect of Pretreatment by using Electron Beam Irradiation on Oil Palm Empty Fruit Bunch

    Directory of Open Access Journals (Sweden)

    A. Kristiani

    2016-04-01

    Full Text Available Oil palm empty fruit bunch (OPEFB is a potential type of lignocellulosic biomass for second-generation bioethanol production. The pretreatment process is an important process in the series of processes to produce bioethanol. This research aims to study the effects of pretreatment process by using electron beam irradiation to OPEFB’s characterization as raw materials for the hydrolysis reaction to produce monomer sugars which will be fermented into ethanol. The untreated and treated OPEFB are characterized in terms of their physical and chemical properties. Analysis results of the compositional analysis by using NREL/TP-510-42618 method show that after pretreatment by using electron beam irradiation, OPEFB's total lignin content is changed little while its cellulose and hemicellulose contents tend to decrease with increasing irradiation dose. X-ray diffraction (XRD analysis shows that there is a decrease of crystallinity compared to untreated OPEFB, except for 200-kGy irradiated OPEFB. The highest decrease of crystallinity was shown by 300-kGy irradiated OPEFB. Further, crystallite sizes of treated OPEFBs are not significantly different from the untreated, except for the 200-kGy irradiated OPEFB. Irradiation pretreatment also increases specific surface area, pore volume, and pore size. The IR spectra analysis show the absorption of cellulose, hemicellulose, and lignin.

  17. Formation of space-charge bunches in a multivelocity-electron-beam-based microwave oscillator with a cathode unshielded from the magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Yu. A.; Starodubov, A. V.; Fokin, A. S., E-mail: alexander1989fokin@mail.ru [Saratov State University (Russian Federation)

    2017-02-15

    The influence of the magnitude and configuration of the magnetic field on the parameters of electron bunches formed in a multivelocity electron beam is analyzed. It is shown that the use of a cathode unshielded from the magnetic field and a nonuniform magnetic field increasing along the drift space enables the formation of compact electron bunches. The ratio between the current density in such bunches and the beam current density at the entrance to the drift space reaches 10{sup 6}, which results in a substantial broadening of the output microwave spectrum due to an increase in the amplitudes of the higher harmonics of the fundamental frequency.

  18. Theoretical estimation and experimental design of high-intensity far-infrared to MM-wave coherent synchrotron radiation generated by short electron bunches at BFEL

    International Nuclear Information System (INIS)

    Zhu Junbiao; Li Yonggui; Xie Jialin

    2000-01-01

    Broadband continuous and high-intensity coherent synchrotron radiation (CSR) emitted from 4 ps electron bunches provided by the 30 MeV RF linac of Beijing FEL is analyzed and numerically calculated using an exact series expansion for the infinite integral of fractional modified Bessel function. CSR in the mm-wave and far-IR to mm-wave regions can be respectively generated by directly using these bunches and by applying those ones compressed to ≤=1 ps. The CSR powers, approximately as 10 8 -10 9 times as the SR ones, in the range from several hundred microwatts to milliwatts are dependent on chosen electron density distribution, wavelength range, and gathering angle. The power produced by rectangular bunches is greater than that generated by Gaussian ones. The shorter the bunch, the stronger the produced CSR, the greater the energy concentrated to the far-IR end. Experiments to generate CSR and measure the bunch length are designed

  19. Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control

    NARCIS (Netherlands)

    Witte, S.; Baclayon, M.; Peterman, E.J.G.; Toonen, R.F.G.; Mansvelder, H.D.; Groot, M.L.

    2009-01-01

    We present a full-range Fourier-domain optical coherence tomography (OCT) system that is capable of acquiring two-dimensional images of living tissue in a single shot. By using line illumination of the sample in combination with a two-dimensional imaging spectrometer, 1040 depth scans are performed

  20. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    ... mother by increasing self esteem and improving bonding with the baby. Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study

  1. A second-order autocorrelator for single-shot measurement of ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    mental and second-harmonic frequency respectively, and 2α is the crossover angle of the beams inside the ... dispersion (GVD) effects in the crystal and spatial resolution of the imaging system. In the case ... Figure 3a shows the image of SH radiation from the KDP crystal corresponding to the single- shot operation of the ...

  2. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  3. Cherenkov radiation by an electron bunch that moves in a vacuum above a left-handed material

    International Nuclear Information System (INIS)

    Averkov, Yu.O.; Yakovenko, V.M.

    2005-01-01

    Cherenkov radiation by a nonrelativistic electron bunch that moves above an interface of a vacuum-left-handed material has been investigated theoretically. The electron density of the bunch is described by a Gauss distribution. Cherenkov radiation for the frequency range where the refractive index is negative is shown to lead to simultaneous excitation of both bulk and surface electromagnetic waves over one and the same frequency range. In this case the wave vector magnitude in the plane of the interface of surface electromagnetic waves is larger than the corresponding wave vector magnitude of bulk electromagnetic waves. The energy flows in a left-handed material have been calculated. The spectral density and the radiation pattern have been investigated

  4. Electro-Optical Detection of Coherent Radiation Induced by Relativistic Electron Bunches in the Near and Far Fields

    Science.gov (United States)

    Curcio, A.; Anania, M.; Bisesto, F.; Botton, M.; Castellano, M.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Galletti, M.; Giulietti, D.; Henis, Z.; Petrarca, M.; Pompili, R.; Schleifer, E.; Zigler, A.

    2018-02-01

    Coherent radiation produced by relativistic charged bunches is nowadays of great interest for user-oriented applications and high-resolution diagnostics. Here we present experimental results obtained by using a temporal monitor based on the electro-optical sampling that allows us to reveal the features of the radiation emitted in terahertz range by ultrashort electron bunches moving in proximity to a nonlinear crystal. We investigate the radiation properties both in near- and far-field conditions by employing electron beams accelerated by a conventional photoinjector and through laser-plasma interactions. Our results indicate that the emitted radiation moves collinearly with the beam in one case, while its properties resemble those of the classical Cherenkov radiation in a second case.

  5. Inversion recovery single-shot TurboFLASH for assessment of myocardial infarction at 3 Tesla.

    Science.gov (United States)

    Bauner, Kerstin U; Muehling, Olaf; Wintersperger, Bernd J; Winnik, Eva; Reiser, Maximilian F; Huber, Armin

    2007-06-01

    The aim of the study was to assess the diagnostic accuracy of imaging myocardial infarction with a single-shot inversion recovery turbofast low-angle shot (SS IR turboFLASH) sequence at 3.0 Tesla in comparison with an established segmented inversion recovery turboFLASH sequence at 1.5 Tesla. Fifteen patients with myocardial infarction were examined at a 1.5 Tesla magnetic resonance (MR) System (Avanto, Siemens, Medical Solutions) and at a 3.0 Tesla MR system (TIM Trio, Siemens, Medical Solutions). Imaging delayed enhancement was started 15 minutes after application of contrast material. A SS IR turboFLASH was performed at 3.0 Tesla and compared with a segmented IR turboFLASH sequence at 1.5 and at 3.0 Tesla. The IR turboFLASH sequence at 1.5 Tesla served as reference method. Infarct volumes, contrast/noise ratio (CNR) of infarcted and normal myocardium were compared with the reference method. The Single-Shot IR turboFLASH technique allows imaging 9 slices during a single breath-hold. The CNR between infarction and normal myocardium of the reference method was 6.4 at 1.5 Tesla. The mean value of CNR of the IR turboFLASH sequence was 7.3 at 3.0 Tesla for the single-shot technique and 14.1 at 3.0 Tesla for the segmented technique. No significant difference was found for the CNR values of the reference technique at 1.5 Tesla and the single-shot technique at 3.0 Tesla, however for the comparison of the segmented technique at 1.5 and at 3 Tesla (P = 0.0001). The correlation coefficients of the infarct volumes, determined with the Single-Shot IR turboFLASH and the segmented IR turboFLASH technique at 3.0 compared with the reference method, were r = 0.95 (P < 0.0001) and r = 0.95 (P < 0.0001). The loss of CNR, which is caused by replacement of the segmented technique by the single-shot technique, is completely compensated by the approximately 2-fold CNR increase at the higher field strength. The IR turboFLASH technique at 3.0 Tesla IR can be used as a single-shot technique

  6. MR cholangiopancreatography of pancreaticobiliary diseases: Comparison of single-shot RARE and multislice HASTE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Morrin, Martina M.; Farrell, Richard J.; McEntee, Gerry; MacMathuna, Padraic; Stack, John P.; Murrah, John G

    2000-11-01

    AIMS: We prospectively compared two breath-hold magnetic resonance cholangiopancreatography (MRCP) sequences: single-shot rapid acquisition with relaxation enhancement (RARE) and multislice half-Fourier acquisition single-shot turbo spin echo (HASTE) in imaging the pancreaticobiliary system. PATIENTS AND METHODS: The diagnostic accuracy of single-shot RARE and multislice HASTE was studied in 34 subjects who had undergone conventional cholangiopancreatography. Overall image quality, duct conspicuity, image artifact, signal intensity and contrast-to-noise ratios were assessed independently by two radiologists who were unaware of the underlying diagnosis. RESULTS: Both sequences had comparable diagnostic accuracy regarding a normal biliary system, choledocholithiasis, extra-hepatic and intra-hepatic strictures. Single-shot RARE was superior to multislice HASTE in diagnosing a normal pancreatic system, pancreatic and intrahepatic duct strictures, while providing significantly better image quality (mean {+-} SE 3.7 {+-} 0.07 vs 3.3 {+-} 0.08: P = 0.02) and significantly less image artifact (mean {+-} SE 3.6 {+-} 0.07 vs 3.2 {+-} 0.08:P = 0.01). Single-shot RARE provided significantly better duct conspicuity regarding the pancreatic duct within the body (2.7 {+-} 0.2 vs 2.1 {+-} 0.2: P = 0.003) and tail (2.4 {+-} 0.2 vs 1.6 {+-} 0.2;P = 0.0001), as well as the intrahepatic ducts (3.0 {+-} 0.1 vs 2.6 {+-} 0.1: P = 0.004) but there was no significant difference regarding the remainder of the biliary tree. CONCLUSION: Single-shot RARE provides superior image quality, duct conspicuity with the added advantage of less image artifact and shorter acquisition time. However, volume averaging can cause common bile duct stones to be missed. Therefore, multislice HASTE sequences should still be acquired if choledocholithiasis is suspected. Larger studies are required to assess the diagnostic efficacy of single-shot RARE sequences in pancreatic duct and intra-hepatic duct disease

  7. Time-resolved electron beam phase space tomography at a soft x-ray free-electron laser

    Directory of Open Access Journals (Sweden)

    Michael Röhrs

    2009-05-01

    Full Text Available High-gain free-electron lasers (FELs in the ultraviolet and x-ray regime put stringent demands on the peak current, transverse emittance, and energy spread of the driving electron beam. At the soft x-ray FEL FLASH, a transverse deflecting microwave structure (TDS has been installed to determine these parameters for the longitudinally compressed bunches, which are characterized by a narrow leading peak of high charge density and a long tail. The rapidly varying electromagnetic field in the TDS deflects the electrons vertically and transforms the time profile into a streak on an observation screen. The bunch current profile was measured single shot with an unprecedented resolution of 27 fs under FEL operating conditions. A precise single-shot measurement of the energy distribution along a bunch was accomplished by using the TDS in combination with an energy spectrometer. Variation of quadrupole strengths allowed for a determination of the horizontal emittance as a function of the longitudinal position within a bunch, the so-called slice emittance. In the bunch tail, a normalized slice emittance of about 2  μm was found, in agreement with expectations. In the leading spike, however, surprisingly large emittance values were observed, in apparent contradiction with the low emittance deduced from the measured FEL gain. By applying three-dimensional phase space tomography, we were able to show that the bunch head contains a central core of low emittance and high local current density, which is presumably the lasing part of the bunch.

  8. On the quantitative prediction of bunch lengthening in high energy electron storage rings

    International Nuclear Information System (INIS)

    Weiland, T.

    1981-12-01

    The longitudinal current dependent electromagnetic interaction between a bunch of charged particles and accelerator components can be described by a Green's Function in time domain or by an impedance in frequency domain. The aim of this paper is to describe a procedure which yields an approximate Green's Function for cylindrically symmetric objects. Once this Green's Function is quantitatively known the equation of motion for the particles can be solved easily by a turn-by-turn tracking code on a computer. Thus it is possible to predict the bunch length and width as a function of charge per bunch for future accelerators and storage rings based on pure geometrical data of the accelerator components. Results are presented for PETRA and LEP. A comparison between measurements at PETRA and computations shows an excellent agreement. (orig.)

  9. Generation of stable and low-divergence 10-MeV quasimonoenergetic electron bunch using argon gas jet

    OpenAIRE

    M. Mori; K. Kondo; Y. Mizuta; M. Kando; H. Kotaki; M. Nishiuchi; M. Kado; A. S. Pirozhkov; K. Ogura; H. Sugiyama; S. V. Bulanov; K. A. Tanaka; H. Nishimura; H. Daido

    2009-01-01

    The pointing stability and divergence of a quasimonoenergetic electron bunch generated in a self-injected laser-plasma acceleration regime using 4 TW laser is studied. A pointing stability of 2.4 mrad root-mean-square (rms) and a beam divergence of 10.6 mrad (rms) were obtained using an argon gas-jet target for 50 sequential shots, while these values were degraded by a factor of 3 at the optimum condition using helium. The peak electron energies were 8.5±0.7 and 24.8±3.6  MeV using argon and ...

  10. Speckle noise reduction in single-shot holographic two-wavelength contouring

    Science.gov (United States)

    Agour, Mostafa; Klattenhoff, Reiner; Falldorf, Claas; Bergmann, Ralf B.

    2017-05-01

    We present an experimental configuration that enables form measurement from a single-shot camera exposure. It combines two-wavelength contouring with spatial multiplexing synthetic-aperture digital holography. The synthetic-aperture in this work is formed by simultaneously illuminating the test object from two different angles. The two illumination directions and the two-wavelength contouring result in four holograms which are spatially multiplexed on a single camera target avoiding unwanted cross-interference between them by means of coherence gating. In contrast to standard holographic contouring methods, the proposed technique reduces speckle decorrelation noise and enables single shot form measurement. To demonstrate this technique, the shape of a micro cold drawing part is determined.

  11. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-02-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  12. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  13. Single-shot observation of growing streamers using an ultrafast camera

    International Nuclear Information System (INIS)

    Takahashi, E; Kato, S; Furutani, H; Sasaki, A; Kishimoto, Y; Takada, K; Matsumura, S; Sasaki, H

    2011-01-01

    A recently developed ultrafast camera that can acquire 10 8 frames per second was used to investigate positive streamer discharge. It enabled single-shot evaluation of streamer evolution without the need to consider shot-to-shot reproducibility. This camera was used to investigate streamers in argon. Growing branches, the transition when a streamer forms a return stroke, and related phenomena were clearly observed. (fast track communication)

  14. Single-Shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator

    Science.gov (United States)

    2016-01-11

    Single-shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator Philip Kranz1, Andreas Bengtsson1, Michaël Simoen1, Simon...Josephson Parametric Oscillator Philip Krantz1, Andreas Bengtsson1, Michaël Simoen1, Simon Gustavsson2, Vitaly Shumeiko1, W. D. Oliver2,3, C. M...2016) We propose and demonstrate a new read-out technique for a superconducting qubit by dispersively coupling it to a Josephson parametric

  15. Reliability Assessment of a Single-Shot System by Use of Screen Test Results

    Science.gov (United States)

    2018-02-01

    unlimited. NUWC Keyport #17-002. Reliability Assessment of a Single-Shot System by Use of Screen Test Results Abstract: Field reliability prediction...approach described here assumes that the defect density during testing takes the form of an exponential decay, although other mathematical functions can...be substituted for the exponential. In order to apply the decay rate function to a discrete pass/fail test scheme, the approach provides for

  16. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  17. On the Asymmetric Focusing of Low-Emittance Electron Bunches via Active Lensing by Using Capillary Discharges

    Science.gov (United States)

    Bulanov, Stepan; Bagdasarov, Gennadiy; Bobrova, Nadezhda; Boldarev, Alexey; Olkhovskaya, Olga; Sasorov, Pavel; Gasilov, Vladimir; Barber, Samuel; Gonsalves, Anthony; Schroeder, Carl; van Tilborg, Jeroen; Esarey, Eric; Leemans, Wim; Levato, Tadzio; Margarone, Daniele; Korn, Georg; Kando, Masaki; Bulanov, Sergei

    2017-10-01

    A novel method for asymmetric focusing of electron beams is proposed. The scheme is based on the active lensing technique, which takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside a capillary discharge are described theoretically and modeled with dissipative MHD simulations to enable analysis of capillaries of oblong rectangle cross-sections implying that large aspect ratio rectangular capillaries can be used to form flat electron bunches. The effect of the capillary cross-section on the electron beam focusing properties were studied using the analytical methods and simulation- derived magnetic field map showing the range of the capillary discharge parameters required for producing the high quality flat electron beams.

  18. Investigations on the electron bunch distribution in the longitudinal phase space at a laser driven RF electron source for the European X-FEL

    Energy Technology Data Exchange (ETDEWEB)

    Roensch, Juliane

    2010-01-15

    The Photoinjector Test facility at DESY, Zeuthen site, (PITZ) is aiming for the optimization of electron guns for SAS-FELs. For this it is necessary to investigate the characteristics of the six dimensional phase space of the bunch produced by a photoinjector. This thesis is focused on the analysis of the longitudinal properties of the electron bunch distribution, this means the temporal current distribution and the momentum distribution as well as the correlation of both properties. The complete distribution of the electron bunch in longitudinal phase space of a photoinjector was measured directly for the first time at a beam momentum of about 5 MeV/c, using an existing apparatus. This system had been designed for an accelerating gradient of 40 MV/m. Its subcomponents were analysed to understand sources of uncertainties of the measurement system. The usage of higher accelerating gradients in the gun (60 MV/m, resulting in a beam momentum of about 6.8 MeV/c) demands major modifications of the existing measurement system for the longitudinal phase space distribution. An upgrade of the facility by an additional accelerating cavity required the design of further longitudinal diagnostics systems for the analysis at higher momenta (up to 40 MeV/c). Measurements of the longitudinal beam properties to determine the influence of different operation parameters, like RF launch phase, charge, accelerating field gradient and laser distribution were performed and compared to simulations. (orig.)

  19. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...37081 Göttingen, Germany 4School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA 5trmeyer@purdue.edu 6james.gord...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow

  20. Electron beam bunch length characterizations using incoherent and coherent transition radiation on the APS SASE FEL project

    CERN Document Server

    Lumpkin, Alex H; Berg, W J; Lewellen, J W; Sereno, N S; Happek, U

    2000-01-01

    The Advanced Photon Source (APS) injector linac has been reconfigured with a low-emittance RF thermionic gun and a photocathode (PC) RF gun to support self-amplified spontaneous emission (SASE) free-electron laser (FEL) experiments. One of the most critical parameters for optimizing SASE performance (gain length) is the electron beam peak current, which requires a charge measurement and a bunch length measurement capability. We report here initial measurements of the latter using both incoherent optical transition radiation (OTR) and coherent transition radiation (CTR). A visible light Hamamatsu C5680 synchroscan streak camera was used to measure the thermionic RF gun beam's bunch length (sigma approx 2-3 ps) via OTR generated by the beam at 220 MeV and 200 mA macropulse average current. In addition, a CTR monitor (Michelson Interferometer) based on a Golay cell as the far-infrared (FIR) detector has been installed at the 40-MeV station in the beamline. Initial observations of CTR signal strength variation wi...

  1. Anti-botulism single-shot vaccine using chitosan for protein encapsulation by simple coacervation.

    Science.gov (United States)

    Sari, Roger S; de Almeida, Anna Christina; Cangussu, Alex S R; Jorge, Edson V; Mozzer, Otto D; Santos, Hércules Otacílio; Quintilio, Wagner; Brandi, Igor Viana; Andrade, Viviane Aguiar; Miguel, Angelo Samir M; Sobrinho Santos, Eliane M

    2016-12-01

    The aim of the present study was to compare the potency and safety of vaccines against Clostridium botulinum (C. botulinum) type C and D formulated with chitosan as controlled release matrix and vaccines formulated in conventional manner using aluminum hydroxide. Parameters were established for the development of chitosan microspheres, using simple coacervation to standardize the use of this polymer in protein encapsulation for vaccine formulation. To formulate a single shot vaccine inactivated antigens of C. botulinum type C and D were used with original toxin titles equal to 5.2 and 6.2 log LD50/ml, respectively. For each antigen a chitosan based solution of 50 mL was prepared. Control vaccines were formulated by mixing toxoid type C and D with aluminum hydroxide [25% Al(OH) 3 , pH 6.3]. The toxoid sterility, innocuity and potency of vaccines were evaluated as stipulated by MAPA-BRASIL according to ministerial directive no. 23. Encapsulation efficiency of BSA in chitosan was 32.5-40.37%, while that the encapsulation efficiency to toxoid type C was 41,03% (1.94 mg/mL) and of the toxoid type D was 32.30% (1.82 mg/mL). The single shot vaccine formulated using chitosan for protein encapsulation through simple coacervation showed potency and safety similar to conventional vaccine currently used in Brazilian livestock (10 and 2 IU/mL against C. botulinum type C and D, respectively). The present work suggests that our single shot vaccine would be a good option as a cattle vaccine against these C. botulinum type C and D. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  4. Deconvolution single shot multibox detector for supermarket commodity detection and classification

    Science.gov (United States)

    Li, Dejian; Li, Jian; Nie, Binling; Sun, Shouqian

    2017-07-01

    This paper proposes an image detection model to detect and classify supermarkets shelves' commodity. Based on the principle of the features directly affects the accuracy of the final classification, feature maps are performed to combine high level features with bottom level features. Then set some fixed anchors on those feature maps, finally the label and the position of commodity is generated by doing a box regression and classification. In this work, we proposed a model named Deconvolutiuon Single Shot MultiBox Detector, we evaluated the model using 300 images photographed from real supermarket shelves. Followed the same protocol in other recent methods, the results showed that our model outperformed other baseline methods.

  5. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  6. Generation of stable and low-divergence 10-MeV quasimonoenergetic electron bunch using argon gas jet

    Directory of Open Access Journals (Sweden)

    M. Mori

    2009-08-01

    Full Text Available The pointing stability and divergence of a quasimonoenergetic electron bunch generated in a self-injected laser-plasma acceleration regime using 4 TW laser is studied. A pointing stability of 2.4 mrad root-mean-square (rms and a beam divergence of 10.6 mrad (rms were obtained using an argon gas-jet target for 50 sequential shots, while these values were degraded by a factor of 3 at the optimum condition using helium. The peak electron energies were 8.5±0.7 and 24.8±3.6  MeV using argon and helium, respectively. The experimental results indicate that the different propagation condition could be generated with the different material, although it is performed with the same irradiation condition.

  7. Experimental investigations on the influence of the photocathode laser pulse parameters on the electron bunch quality in an RF-photoelectron source

    Energy Technology Data Exchange (ETDEWEB)

    Haenel, Marc

    2010-07-15

    Free Electron Lasers based on the SASE principle like the European XFEL require electron bunches having peak currents of several kiloamperes as well as very low transverse emittance. While high peak currents can be generated using longitudinal bunch compression techniques, the transverse emittance must have values as low as 1mmmrad already at the source. The development of electron sources fulfilling these demanding specifications is the goal of the Photo Injector Test Facility (PITZ) in DESY, Zeuthen site. The key component of a photoinjector is the electron gun cavity where the electrons bunches are generated and immediately accelerated. The extraction of the electrons is based on the photoelectric effect of the cathode which requires a laser system having special capabilities. In the first part of the thesis, measurements are presented which were performed to investigate whether the laser and the laser transport system fulfill these requirements. The second part of the thesis is dedicated to simulations as well as experimental studies on the impact of the temporal and spatial parameters of the laser pulses on the electron bunch quality. This influence is possible because the response time of the Cs{sub 2}Te photocathode is short compared to the laser pulse duration. Based on these investigations, suggestions for improvements are given and tolerances for the laser pulse properties are defined. (orig.)

  8. Experimental investigations on the influence of the photocathode laser pulse parameters on the electron bunch quality in an RF-photoelectron source

    International Nuclear Information System (INIS)

    Haenel, Marc

    2010-06-01

    Free Electron Lasers based on the SASE principle like the European XFEL require electron bunches having peak currents of several kiloamperes as well as very low transverse emittance. While high peak currents can be generated using longitudinal bunch compression techniques, the transverse emittance must have values as low as 1mmmrad already at the source. The development of electron sources fulfilling these demanding specifications is the goal of the Photo Injector Test Facility (PITZ) in DESY, Zeuthen site. The key component of a photoinjector is the electron gun cavity where the electrons bunches are generated and immediately accelerated. The extraction of the electrons is based on the photoelectric effect of the cathode which requires a laser system having special capabilities. In the first part of the thesis, measurements are presented which were performed to investigate whether the laser and the laser transport system fulfill these requirements. The second part of the thesis is dedicated to simulations as well as experimental studies on the impact of the temporal and spatial parameters of the laser pulses on the electron bunch quality. This influence is possible because the response time of the Cs 2 Te photocathode is short compared to the laser pulse duration. Based on these investigations, suggestions for improvements are given and tolerances for the laser pulse properties are defined. (orig.)

  9. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  10. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout

    Science.gov (United States)

    Sukachev, D. D.; Sipahigil, A.; Nguyen, C. T.; Bhaskar, M. K.; Evans, R. E.; Jelezko, F.; Lukin, M. D.

    2017-12-01

    The negatively charged silicon-vacancy (SiV- ) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (˜250 ns ) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV- electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV- symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV- spin with 89% fidelity. Coherent control of the SiV- spin with microwave fields is used to demonstrate a spin coherence time T2 of 13 ms and a spin relaxation time T1 exceeding 1 s at 100 mK. These results establish the SiV- as a promising solid-state candidate for the realization of quantum networks.

  11. High-harmonic electron bunching in the field of a signal wave and the use of this effect in cyclotron masers with frequency multiplication

    Directory of Open Access Journals (Sweden)

    I. V. Bandurkin

    2005-01-01

    Full Text Available A method of organizing electron-wave interaction at the multiplied frequency of the signal wave is proposed. This type of electron-wave interaction provides multiplied-frequency electron bunching, which leads to formation of an intense harmonic of the electron current at a selected multiplied frequency of the signal wave. This effect is attractive for the use in klystron-type cyclotron masers with frequency multiplication as a way to increase the output frequency and improve the selectivity.

  12. Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera

    CERN Document Server

    Watanabe, T; Yoshimatsu, T; Sasaki, S; Sugiyama, Y; Ishi, K; Shibata, Y; Kondo, Y; Yoshii, K; Ueda, T; Uesaka, M

    2002-01-01

    Measurements of longitudinal bunch length of subpicosecond and picosecond electron beams have been performed by three methods with three radiation sources at the 35 MeV S-band twin liner accelerators at Nuclear Engineering Research Laboratory, University of Tokyo. The methods we adopt are the femtosecond streak camera with a nondispersive reflective optics, the coherent transition radiation (CTR) Michelson interferometer and the 10 ch polychromator that detects the spectrum of CTR and coherent diffraction radiation (CDR). The measurements by the two CTR methods were independently done with the streak camera and their results were consistent with one another. As a result, the reliability of the polychromator for the diagnostics of less than picosecond electron bunch and the usefulness of the diagnostics for the single shot measurement were verified. Furthermore, perfect nondestructive diagnostics for subpicosecond bunches was performed utilizing CDR interferometry. Then the good agreement between CDR interfero...

  13. Misconceptions regarding the cancellation of self-forces in the transverse equation of motion for an electron in a bunch

    International Nuclear Information System (INIS)

    Geloni, G.; Yurkov, M.V.

    2003-10-01

    As a consequence of motions driven by external forces, self-fields originate within an electron bunch, which are different from the static case. In the case of magnetic external forces acting on an ultrarelativistic beam, the longitudinal self-interactions are responsible for CSR (coherent synchrotron radiation)-related phenomena, which have been studied extensively. On the other hand, transverse self-interactions are present too. At the time being, several existing theoretical analysis of transverse dynamics rely on the so-called cancellation effect, which has been around for more than ten years. In this paper we explain why in our view such an effect is not of practical nor of theoretical importance. (orig.)

  14. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  15. Double Emittance Exchanger as a Bunch Compressor for the MaRIE XFEL electron beam line at 1GeV

    Energy Technology Data Exchange (ETDEWEB)

    Malyzhenkov, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Northern Illinois Univ., DeKalb, IL (United States); Yampolsky, Nikolai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Carlsten, Bruce Eric [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-22

    We demonstrate an alternative realization of a bunch compressor (specifically the second bunch compressor for the MaRIE XFEL beamline, 1GeV electron energy) using a double emittance exchanger (EEX) and a telescope in the transverse phase space.We compare our results with a traditional bunch compressor realized via chicane, taking into account the nonlinear dynamics, Coherent Synchrotron Radiation (CSR) and Space Charge (SC) effects. In particular, we use the Elegant code for tracking particles through the beam line and analyze the eigen-emittances evolution to separate the influence of the CSR/SC effects from the nonlinear dynamics effects. We optimize the scheme parameters to reach a desirable compression factor and minimize the emittance growth. We observe dominant CSR-effects in our scheme resulting in critical emittance growth and introduce alternative version of an emittance exchanger with a reduced number of bending magnets to minimize the impact of CSR effects.

  16. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  17. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  18. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  19. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  20. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  1. Single-shot in-line digital holography without twin image

    Science.gov (United States)

    Nomura, Takanori

    2018-01-01

    In-line digital holography is conventional but still attractive because of its simple optical setup. In general, sequential phase-shifting technique is mandatory to remove twin-image which makes the reconstructed image quality low. However, sequential phase-shifting technique requires multiple recording. Multiple recording means that it is not suitable for a dynamic phenomenon. In this paper, two kinds of a single-shot in-line digital holography without twin-image using a diffused illumination are presented. One is a generalized phase-shifting digital holography and the other is a computational removal of twin-image. The ideas and their experimental results are given to confirm the feasibility.

  2. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  3. Single-shot read-out of a superconducting qubit using a Josephson parametric oscillator

    Science.gov (United States)

    Krantz, Philip; Bengtsson, Andreas; Simoen, Michaël; Gustavsson, Simon; Shumeiko, Vitaly; Oliver, W. D.; Wilson, C. M.; Delsing, Per; Bylander, Jonas

    2016-01-01

    We propose and demonstrate a read-out technique for a superconducting qubit by dispersively coupling it with a Josephson parametric oscillator. We employ a tunable quarter wavelength superconducting resonator and modulate its resonant frequency at twice its value with an amplitude surpassing the threshold for parametric instability. We map the qubit states onto two distinct states of classical parametric oscillation: one oscillating state, with 185±15 photons in the resonator, and one with zero oscillation amplitude. This high contrast obviates a following quantum-limited amplifier. We demonstrate proof-of-principle, single-shot read-out performance, and present an error budget indicating that this method can surpass the fidelity threshold required for quantum computing. PMID:27156732

  4. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  5. Single shot near edge x-ray absorption fine structure spectroscopy in the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mantouvalou, I., E-mail: ioanna.mantouvalou@tu-berlin.de; Witte, K.; Martyanov, W.; Jonas, A.; Grötzsch, D.; Kanngießer, B. [Institute for Optics and Atomic Physics, Technical University of Berlin, D-10623 Berlin (Germany); Streeck, C. [Physikalisch-Technische Bundesanstalt (PTB), D-10587 Berlin (Germany); Löchel, H.; Rudolph, I.; Erko, A. [Helmholtz-Zentrum Berlin, D-14109 Berlin (Germany); Stiel, H. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, D-12489 Berlin (Germany)

    2016-05-16

    With the help of adapted off-axis reflection zone plates, near edge X-ray absorption fine structure spectra at the C and N K-absorption edge have been recorded using a single 1.2 ns long soft X-ray pulse. The transmission experiments were performed with a laser-produced plasma source in the laboratory rendering time resolved measurements feasible independent on large scale facilities. A resolving power of E/ΔE ∼ 950 at the respective edges could be demonstrated. A comparison of single shot spectra with those collected with longer measuring time proves that all features of the used reference samples (silicon nitrate and polyimide) can be resolved in 1.2 ns. Hence, investigations of radiation sensitive biological specimen become possible due to the high efficiency of the optical elements enabling low dose experiments.

  6. Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: a case study on GBS electron LINAC at ELI-NP

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Cianchi, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Variola, A.

    2018-02-01

    In high-brightness LINear ACcelerators (LINACs), electron bunch length can be measured indirectly by a radio frequency deflector (RFD). In this paper, the accuracy loss arising from non-negligible correlations between particle longitudinal positions and the transverse plane (in particular the vertical one) at RFD entrance is analytically assessed. Theoretical predictions are compared with simulation results, obtained by means of ELEctron Generation ANd Tracking (ELEGANT) code, in the case study of the gamma beam system (GBS) at the extreme light infrastructure—nuclear physics (ELI-NP). In particular, the relative error affecting the bunch length measurement, for bunches characterized by both energy chirp and fixed correlation coefficients between longitudinal particle positions and the vertical plane, is reported. Moreover, the relative error versus the correlation coefficients is shown for fixed RFD phase 0 rad and π rad. The relationship between relative error and correlations factors can help the decision of using the bunch length measurement technique with one or two vertical spot size measurements in order to cancel the correlations contribution. In the case of the GBS electron LINAC, the misalignment of one of the quadrupoles before the RFD between  ‑2 mm and 2 mm leads to a relative error less than 5%. The misalignment of the first C-band accelerating section between  ‑2 mm and 2 mm could lead to a relative error up to 10%.

  7. Light field driven streak-camera for single-shot measurements of the temporal profile of XUV-pulses from a free-electron laser; Lichtfeld getriebene Streak-Kamera zur Einzelschuss Zeitstrukturmessung der XUV-Pulse eines Freie-Elektronen Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Fruehling, Ulrike

    2009-10-15

    The Free Electron Laser in Hamburg (FLASH) is a source for highly intense ultra short extreme ultraviolet (XUV) light pulses with pulse durations of a few femtoseconds. Due to the stochastic nature of the light generation scheme based on self amplified spontaneous emission (SASE), the duration and temporal profile of the XUV pulses fluctuate from shot to shot. In this thesis, a THz-field driven streak-camera capable of single pulse measurements of the XUV pulse-profile has been realized. In a first XUV-THz pump-probe experiment at FLASH, the XUV-pulses are overlapped in a gas target with synchronized THz-pulses generated by a new THz-undulator. The electromagnetic field of the THz light accelerates photoelectrons produced by the XUV-pulses with the resulting change of the photoelectron momenta depending on the phase of the THz field at the time of ionisation. This technique is intensively used in attosecond metrology where near infrared streaking fields are employed for the temporal characterisation of attosecond XUV-Pulses. Here, it is adapted for the analysis of pulse durations in the few femtosecond range by choosing a hundred times longer far infrared streaking wavelengths. Thus, the gap between conventional streak cameras with typical resolutions of hundreds of femtoseconds and techniques with attosecond resolution is filled. Using the THz-streak camera, the time dependent electric field of the THz-pulses was sampled in great detail while on the other hand the duration and even details of the time structure of the XUV-pulses were characterized. (orig.)

  8. Multiobjective optimizations of a novel cryocooled dc gun based ultrafast electron diffraction beam line

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan

    2016-09-01

    We present the results of multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed for three different sample radii: 50, 100, and 200 μ m , for two final bunch charges: 1 05 electrons (16 fC) and 1 06 electrons (160 fC). Example optimal solutions are analyzed, and the effects of disordered induced heating estimated. In particular, a relative coherence length of Lc ,x/σx=0.27 nm /μ m was obtained for a final bunch charge of 1 05 electrons and final bunch length of σt≈100 fs . For a final charge of 1 06 electrons the cryogun produces Lc ,x/σx≈0.1 nm /μ m for σt≈100 - 200 fs and σx≥50 μ m . These results demonstrate the viability of using genetic algorithms in the design and operation of ultrafast electron diffraction beam lines.

  9. Analytic model of bunched beams for harmonic generation in the low-gain free electron laser regime

    Directory of Open Access Journals (Sweden)

    G. Penn

    2006-06-01

    Full Text Available One scheme for harmonic generation employs free electron lasers (FELs with two undulators: the first uses a seed laser to modulate the energy of the electron beam; following a dispersive element which acts to bunch the beam, the second undulator radiates at a higher harmonic. These processes are currently evaluated using extensive calculations or simulation codes which can be slow to evaluate and difficult to set up. We describe a simple algorithm to predict the output of a harmonic generation beam line in the low-gain FEL regime, based on trial functions for the output radiation. Full three-dimensional effects are included. This method has been implemented as a Mathematica® package, named CAMPANILE, which runs rapidly and can be generalized to include effects such as asymmetric beams and misalignments. This method is compared with simulation results using the FEL code GENESIS, both for single stages of harmonic generation and for the LUX project, a design concept for an ultrafast x-ray facility, where multiple stages upshift the input laser frequency by factors of up to 200.

  10. Analysis of bunch by bunch oscillations with bunch trains at injection into LHC at 25 ns bunch spacing

    CERN Document Server

    Bartosik, H

    2012-01-01

    An MD on August 26, 2011 was dedicated to injection studies of bunch trains with 25 ns spacing and nominal intensity of approximately 1×10(11) protons per bunch. Due to an electrical glitch, the MD was stopped after two attempts of injecting a train of 48 bunches for beam 2. Both injections were aborted after less than 0.1 s. In particular, the first attempt with transverse damper on was dumped after 1000 turns while the second attempt with transverse damper off was dumped after 500 turns only. In this note, an analysis of the bunch by bunch oscillation data recorded with the post-mortem system from the transverse damper is presented. The presented data clearly shows the presence of instabilities that affect mainly the second half of the batch. This is compatible with what would be expected qualitatively in the presence of the electron cloud effect.

  11. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  12. Single Bunch Electron Cloud Effects in the NLC Beam Delivery System(LCC-0126)

    Energy Technology Data Exchange (ETDEWEB)

    Chen, D

    2003-12-08

    A positron beam passing through a linear collider beam delivery beam line is finely focused to desired specifications during collimation and especially in Final Focusing (FFS). Undesired additional focusing is generated by beam-electron cloud interactions, which typically leads to beam size increases at high cloud densities. This paper examines the severity of the electron cloud effects and assesses the critical cloud density.

  13. Characterization of electron bunches from field emitter array cathodes for use in next-generation x-ray free electron lasers

    International Nuclear Information System (INIS)

    Leemann, S. C.

    2007-01-01

    PSI is interested in developing an x-ray free electron laser (X-FEL) as a companion radiation source to the existing Swiss Light Source. In order to achieve radiation wavelengths as low as 1 Α, the X-FEL requires excellent electron beam quality and high beam energy. The energy requirements and thus the size and cost of the project can be reduced considerably if an ultra-low emittance electron source is developed. Therefore PSI has started the Low Emittance Gun Project with the aim to design a novel type of electron source that will deliver an electron beam with unprecedented emittance at high peak currents to the linear accelerator of the proposed X-FEL. A source candidate for such a gun is field emission from cold cathodes. In order to gain first experience with field emission guns, investigate the dynamics of space charge dominated electron beams and to develop diagnostics capable of resolving ultra-low emittances, it was decided to build a 100 keV DC gun test stand. In the scope of this thesis, the test stand has been designed, assembled and commissioned. For the first time, transverse phase space measurements of bunches emitted by field emitter arrays in pulsed DC accelerating fields have been performed. (author)

  14. Determination of electron bunch shape using transition radiation and phase-energy measurements

    International Nuclear Information System (INIS)

    Crosson, E.R.; Berryman, K.W.; Richman, B.A.

    1995-01-01

    We present data comparing microbunch temporal information obtained from electron beam phase-energy measurements with that obtained from transition radiation auto-correlation measurements. The data was taken to resolve some of the ambiguities in previous transition radiation results. By measuring the energy spectrum of the electron beam as a function of its phase relative to the accelerating field, phase-energy information was extracted. This data was analyzed using tomographic techniques to reconstruct the phase-space distribution assuming an electron energy dependence of E(var-phi) = E o + E acc cos(var-phi), where E o is the energy of an electron entering the field, E acc is the peak energy gain, and var-phi is the phase between the crest of the RF wave and an electron. Temporal information about the beam was obtained from the phase space distribution by taking the one dimensional projection along the time axis. We discuss the use of this technique to verify other transition radiation analysis methods

  15. Determination of electron bunch shape using transition radiation and phase-energy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Crosson, E.R.; Berryman, K.W.; Richman, B.A. [Stanford Univ., CA (United States)] [and others

    1995-12-31

    We present data comparing microbunch temporal information obtained from electron beam phase-energy measurements with that obtained from transition radiation auto-correlation measurements. The data was taken to resolve some of the ambiguities in previous transition radiation results. By measuring the energy spectrum of the electron beam as a function of its phase relative to the accelerating field, phase-energy information was extracted. This data was analyzed using tomographic techniques to reconstruct the phase-space distribution assuming an electron energy dependence of E({var_phi}) = E{sub o} + E{sub acc}cos({var_phi}), where E{sub o} is the energy of an electron entering the field, E{sub acc} is the peak energy gain, and {var_phi} is the phase between the crest of the RF wave and an electron. Temporal information about the beam was obtained from the phase space distribution by taking the one dimensional projection along the time axis. We discuss the use of this technique to verify other transition radiation analysis methods.

  16. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  17. Single shot imaging through turbid medium and around corner using coherent light

    Science.gov (United States)

    Li, Guowei; Li, Dayan; Situ, Guohai

    2018-01-01

    Optical imaging through turbid media and around corner is a difficult challenge. Even a very thin layer of a turbid media, which randomly scatters the probe light, can appear opaque and hide any objects behind it. Despite many recent advances, no current method can image the object behind turbid media with single record using coherent laser illumination. Here we report a method that allows non-invasive single-shot optical imaging through turbid media and around corner via speckle correlation. Instead of being as an obstacle in forming diffractionlimited images, speckle actually can be a carrier that encodes sufficient information to imaging through visually opaque layers. Optical imaging through turbid media and around corner is experimentally demonstrated using traditional imaging system with the aid of iterative phase retrieval algorithm. Our method require neither scan of illumination nor two-arm interferometry or long-time exposure in acquisition, which has new implications in optical sensing through common obscurants such as fog, smoke and haze.

  18. Truly work-like work extraction via a single-shot analysis.

    Science.gov (United States)

    Aberg, Johan

    2013-01-01

    The work content of non-equilibrium systems in relation to a heat bath is often analysed in terms of expectation values of an underlying random work variable. However, when optimizing the expectation value of the extracted work, the resulting extraction process is subject to intrinsic fluctuations, uniquely determined by the Hamiltonian and the initial distribution of the system. These fluctuations can be of the same order as the expected work content per se, in which case the extracted energy is unpredictable, thus intuitively more heat-like than work-like. This raises the question of the 'truly' work-like energy that can be extracted. Here we consider an alternative that corresponds to an essentially fluctuation-free extraction. We show that this quantity can be expressed in terms of a one-shot relative entropy measure introduced in information theory. This suggests that the relations between information theory and statistical mechanics, as illustrated by concepts like Maxwell's demon, Szilard engines and Landauer's principle, extends to the single-shot regime.

  19. Efficient Background Segmentation and Seed Point Generation for a Single-Shot Stereo System

    Science.gov (United States)

    Chen, Xiaobo; Xi, Juntong

    2017-01-01

    Single-shot stereo 3D shape measurement is becoming more popular due to its advantages of noise robustness and short acquisition period. One of the key problems is stereo matching, which is related to the efficiency of background segmentation and seed point generation, etc. In this paper, a more efficient and automated matching algorithm based on digital image correlation (DIC) is proposed. The standard deviation of image gradients and an adaptive threshold are employed to segment the background. Scale-invariant feature transform (SIFT)-based feature matching and two-dimensional triangulation are combined to estimate accurate initial parameters for seed point generation. The efficiency of background segmentation and seed point generation, as well as the measuring precision, are evaluated by experimental simulation and real tests. Experimental results show that the average segmentation time for an image with a resolution of 1280 × 960 pixels is 240 milliseconds. The efficiency of seed point generation is verified to be high with different convergence criteria. PMID:29194415

  20. Overview of bunch length measurements

    International Nuclear Information System (INIS)

    Lumpkin, A. H.

    1999-01-01

    An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed

  1. Single shot three-dimensional pulse sequence for hyperpolarized13C MRI.

    Science.gov (United States)

    Wang, Jiazheng; Wright, Alan J; Hu, De-En; Hesketh, Richard; Brindle, Kevin M

    2017-02-01

    Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstrate its capability to generate 13 C MR images in tumor-bearing mice injected with hyperpolarized [1- 13 C]pyruvate. The pulse sequence acquires a stack-of-spirals at two spin echoes after a single excitation pulse and encodes the kz-dimension in an interleaved manner to enhance robustness to B 0 inhomogeneity. Spectral-spatial pulses are used to acquire dynamic 3D images from selected hyperpolarized 13 C-labeled metabolites. A nominal spatial/temporal resolution of 1.25 × 1.25 × 2.5 mm 3  × 2 s was achieved in tumor images of hyperpolarized [1- 13 C]pyruvate and [1- 13 C]lactate acquired in vivo. Higher resolution in the z-direction, with a different k-space trajectory, was demonstrated in measurements on a thermally polarized [1- 13 C]lactate phantom. The pulse sequence is capable of imaging hyperpolarized 13 C-labeled substrates at relatively high spatial and temporal resolutions and is robust to moderate system imperfections. Magn Reson Med 77:740-752, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  2. Analysis and enhancement of 3D shape accuracy in a single-shot LIDAR sensor

    Science.gov (United States)

    Han, Munhyun; Choi, Gudong; Song, Minhyup; Seo, Hongseok; Mheen, Bongki

    2017-02-01

    The accuracy of timing jitter is of prime importance in the prevalent utilization of Light Detection and Ranging (LiDAR) technology for the real-time high-resolution three-dimensional (3D) image sensor, especially for relatively small object detection in various applications, such as in the fully automated car navigation and military surveillance. To assess the accuracy of timing, that is, the accuracy of the distance or three-dimensional shape, the standard deviation method can be used in the Time-of-Flight (ToF) LiDAR technology. While most timing jitter analyses are mainly based on a fiber-network or open space at a relatively short range distance, more accurate analyses are required to extract more information about the timing jitter at in a 3D image sensor long-range free space conditions for extended LiDAR-related applications. In this paper, utilizing a Single-Shot LiDAR System (SSLs) model with a 400 MHz wideband InGaAs Avalanche Photodiode and a 1550 nm 2 nsec full width at half maximum MOPA fiber laser, we analyzed the precise timing jitter for the implemented SSLs to characterize the measurement results. Additionally, we report the enhanced results for the resolution and precision in the given SSLs using the spline interpolation method from the measured results, and multiple-shot averaging (MSA). Finally, by adapting the proposed method to an implemented high resolution 3D LiDAR prototype, called the STUD LiDAR prototype, which can be understood as one kind of SSLs because it has a single source and a single detector as in a SSLs, we observed and analyzed the 3D resolution enhancement.

  3. The single-shot opto-digitizer; L'optoechantillonneur monocoup

    Energy Technology Data Exchange (ETDEWEB)

    Nail, M.; Gibert, Ph. [CEA/DAM-Ile de France, Dept. de Conception et Realisation des Experimentations (DCRE), 91 - Bruyeres-le-Chatel (France); CEA/DAM-Ile de France, Dept. Laser Puissance, DLP, 91 - Bruyeres-Le-Chatel (France)

    2000-07-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  4. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Reconstruction of the time profile of 20.35 GeV, subpicosecond long electron bunches by means of coherent Smith-Purcell radiation

    Directory of Open Access Journals (Sweden)

    H. L. Andrews

    2014-05-01

    Full Text Available We have used coherent Smith-Purcell radiation (cSPr in order to determine the temporal profile of sub-ps long electron bunches at the Facility for Advanced Accelerator Experimental Tests, at SLAC. The measurements reported here were carried out in June 2012 and April 2013. The rms values for the bunch length varied between 356 to 604 fs, depending on the accelerator settings. The resolution of the system was limited by the range of detectable wavelengths which was, in turn, determined by the choice of the grating periods used in these experiments and the achievable beam-grating separation. The paper gives the details of the various steps in the reconstruction of the time profile and discusses possible improvements to the resolution. We also present initial measurements of the polarization properties of cSPr and of the background radiation.

  6. N-polar GaN/AlGaN/GaN metal-insulator-semiconductor high-electron-mobility transistor formed on sapphire substrate with minimal step bunching

    Science.gov (United States)

    Prasertsuk, Kiattiwut; Tanikawa, Tomoyuki; Kimura, Takeshi; Kuboya, Shigeyuki; Suemitsu, Tetsuya; Matsuoka, Takashi

    2018-01-01

    The metal-insulator-semiconductor (MIS) gate N-polar GaN/AlGaN/GaN high-electron-mobility transistor (HEMT) on a (0001) sapphire substrate, which can be expected to operate with lower on-resistance and more easily work on the pinch-off operation than an N-polar AlGaN/GaN HEMT, was fabricated. For suppressing the step bunching and hillocks peculiar in the N-polar growth, a sapphire substrate with an off-cut angle as small as 0.8° was introduced and an N-polar GaN/AlGaN/GaN HEMT without the step bunching was firstly obtained by optimizing the growth conditions. The previously reported anisotropy of transconductance related to the step was eliminated. The pinch-off operation was also realized. These results indicate that this device is promising.

  7. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  8. Single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser.

    Science.gov (United States)

    Peng, Di; Zhang, Zhiyao; Zeng, Zhen; Zhang, Lingjie; Lyu, Yanjia; Liu, Yong; Xie, Kang

    2018-03-19

    We demonstrate a single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser. The theoretical analysis and simulation results indicate that the dissipative soliton-based optical source with a flat spectrum relieves the envelope-induced signal distortion, and its high energy spectral density helps to improve the signal-to-noise ratio, both of which are favorable for simplifying the optical front-end architecture of a photonic time-stretch digitizer. By employing a homemade dissipative soliton-based passively mode-locked erbium-doped fiber laser in a single-shot photonic time-stretch digitizer, an effective number of bits of 4.11 bits under an effective sampling rate of 100 GS/s is experimentally obtained without optical amplification in the link and pulse envelope removing process.

  9. Energy loss of a high charge bunched electron beam in plasma: Simulations, scaling, and accelerating wakefields

    Directory of Open Access Journals (Sweden)

    J. B. Rosenzweig

    2004-06-01

    Full Text Available The energy loss and gain of a beam in the nonlinear, “blowout” regime of the plasma wakefield accelerator, which features ultrahigh accelerating fields, linear transverse focusing forces, and nonlinear plasma motion, has been asserted, through previous observations in simulations, to scale linearly with beam charge. Additionally, from a recent analysis by Barov et al., it has been concluded that for an infinitesimally short beam, the energy loss is indeed predicted to scale linearly with beam charge for arbitrarily large beam charge. This scaling is predicted to hold despite the onset of a relativistic, nonlinear response by the plasma, when the number of beam particles occupying a cubic plasma skin depth exceeds that of plasma electrons within the same volume. This paper is intended to explore the deviations from linear energy loss using 2D particle-in-cell simulations that arise in the case of experimentally relevant finite length beams. The peak accelerating field in the plasma wave excited behind the finite-length beam is also examined, with the artifact of wave spiking adding to the apparent persistence of linear scaling of the peak field amplitude into the nonlinear regime. At large enough normalized charge, the linear scaling of both decelerating and accelerating fields collapses, with serious consequences for plasma wave excitation efficiency. Using the results of parametric particle-in-cell studies, the implications of these results for observing severe deviations from linear scaling in present and planned experiments are discussed.

  10. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  11. Single-shot readout of a superconducting flux qubit with a flux-driven Josephson parametric amplifier

    Science.gov (United States)

    Lin, Z. R.; Inomata, K.; Oliver, W. D.; Koshino, K.; Nakamura, Y.; Tsai, J. S.; Yamamoto, T.

    2013-09-01

    We report single-shot readout of a superconducting flux qubit by using a flux-driven Josephson parametric amplifier (JPA). After optimizing the readout power, gain of the JPA, and timing of the data acquisition, we observe the Rabi oscillations with a contrast of 74%, which is mainly limited by the bandwidth of the JPA and the energy relaxation of the qubit. The observation of quantum jumps between the qubit eigenstates under continuous monitoring indicates the nondestructiveness of the readout scheme.

  12. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  13. Multi-bunch Feedback Systems

    CERN Document Server

    Lonza, M.

    2014-12-19

    Coupled-bunch instabilities excited by the interaction of the particle beam with its surroundings can seriously limit the performance of circular particle accelerators. These instabilities can be cured by the use of active feedback systems based on sensors capable of detecting the unwanted beam motion and actuators that apply the feedback correction to the beam. Advances in electronic technology now allow the implementation of feedback loops using programmable digital systems. Besides important advantages in terms of flexibility and reproducibility, digital systems open the way to the use of novel diagnostic tools and additional features. We first introduce coupled-bunch instabilities, analysing the equation of motion of charged particles and the different modes of oscillation of a multi-bunch beam, showing how they can be observed and measured. Different types of feedback systems will then be presented as examples of real implementations that belong to the history of multi-bunch feedback systems. The main co...

  14. Multi-bunch feedback systems

    CERN Document Server

    Lonza, M

    2008-01-01

    Coupled-bunch instabilities excited by the interaction of the particle beam with its surroundings can seriously limit the performance of circular particle accelerators. These instabilities can be cured by the use of active feedback systems based on sensors capable of detecting the unwanted beam motion and actuators that apply the feedback correction to the beam. The advances in electronic technology now allow the implementation of feedback loops using programmable digital systems. Besides important advantages in terms of flexibility and reproducibility, digital systems open the way to the use of novel diagnostic tools and additional features. The lecture will first introduce coupled-bunch instabilities analysing the equation of motion of charged particles and the different modes of oscillation of a multi-bunch beam, showing how they can be observed and measured. Different types of feedbacks systems will then be presented as examples of real implementations that belong to the history of multi-bunch feedback sy...

  15. Design of BEPCII bunch current monitor system

    International Nuclear Information System (INIS)

    Zhang Lei; Ma Huizhou; Yue Junhui; Lei Ge; Cao Jianshe; Ma Li

    2008-01-01

    BEPC II is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPC II. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPC II timing system can also use the bunch current database to decide which bucket needs to refill to implement 'top-off' injection. (authors)

  16. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  17. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  18. Pharmaceutical and immunological evaluation of a single-shot hepatitis B vaccine formulated with PLGA microspheres.

    Science.gov (United States)

    Shi, Li; Caulfield, Michael J; Chern, Rey T; Wilson, Roger A; Sanyal, Gautam; Volkin, David B

    2002-04-01

    A single-shot Hepatitis B vaccine formulation using poly(d,l)-lactide-co-glycolide acid (PLGA) microspheres as a delivery system was examined using a variety of biophysical and biochemical techniques as well as immunological evaluation in C3H mice. PLGA microsphere encapsulation of the Hepatitis B surface antigen (HBsAg), a lipoprotein particle, resulted in good recoveries of protein mass, protein particle conformational integrity, and in vitro antigenicity. Some partial delipidation of the HBsAg, however, was observed. The loading and encapsulation efficiency of HBsAg into the PLGA microspheres were measured along with the morphology and size distribution of the vaccine-loaded PLGA microspheres. The in vitro release kinetics of HBsAg from the PLGA microspheres was evaluated and found to be affected by experimental conditions such as stirring rate. HBsAg showed enhanced storage stability at 37 degrees C in the slightly acidic pH range reported to be found inside PLGA microspheres; thus, the antigen is relatively stable under conditions of temperature and pH that may mimic in vivo conditions. The immunogenicity of the microsphere formulations of HBsAg was compared with conventional aluminum adjuvant formulated HBsAg vaccine in C3H mice. Comparisons were made between aluminum formulations (one and two injections), PLGA microsphere formulations (single injection), and a mixture of aluminum and PLGA microsphere formulations (single injection). The nine-month serum antibody titers indicate that a single injection of a mixture of aluminum and PLGA-formulated HBsAg results in equal or better immune responses than two injections of aluminum-formulated HBsAg vaccine. Based on these in vitro and in vivo studies, it is concluded that HBsAg can be successfully encapsulated and recovered from the PLGA microspheres and a mixture of aluminum-adjuvanted and PLGA-formulated HBsAg can auto-boost an immune response in manner comparable to multiple injections of an aluminum

  19. Luminosity geometric reduction factor from colliding bunches with different lengths

    Energy Technology Data Exchange (ETDEWEB)

    Verdu-Andres, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-09-29

    In the interaction point of the future electron-Ion collider eRHIC, the electron beam bunches are at least one order of magnitude shorter than the proton beam bunches. With the introduction of a crossing angle, the actual number of collisions resulting from the bunch collision gets reduced. Here we derive the expression for the luminosity geometric reduction factor when the bunches of the two incoming beams are not equal.

  20. Development of a Bunched Beam Electron Cooler based on ERL and Circulator Ring Technology for the Jefferson Lab Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Benson, Stephen V. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Derbenev, Yaroslav S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Douglas, David R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Hannon, Fay E. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Hutton, Andrew M. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Li, Rui [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Rimmer, Robert A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Roblin, Yves R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Tennant, Christopher D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wang, Haipeng [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, He [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, Yuhong [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2018-01-01

    Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second uses a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.

  1. Certain features of FELs with short bunches

    International Nuclear Information System (INIS)

    Lebedev, A.N.

    2006-01-01

    The report is devoted to physics of free electron lasers operating in the short-wave domain where the bunch length could be less than the undulator length in the proper frame. Then the current component of the signal is locked within the bunch as in a cavity, while the electromagnetic component propagates freely. In contrast with gyrotrons where this regime can be of interest only for wavelengths comparable with the bunch length, we consider short waves in a bunch of arbitrary profile. Both amplification of an external harmonic signal and SASE regime, i.e. selective amplification of proper noises, are investigated

  2. Application of a Low-Energy Electron Beam as a Tool for ultrashort bunch length measurement in circular machines

    CERN Document Server

    Nikiforov, D A; Malyutin, D; Matveenko, A; Rusinov, K; Starostenko, A A

    2017-01-01

    A new diagnostic device designed for non-destructive ultrashort bunch length measurement is described. The operating principle of the device and the measuring technique are described. The possible scheme of arrangement of the device elements are described. The results of simulations of EBP application for different beams under investigation are presented. The quality requirements of the low energy testing beam are considered and resolving detector ability is determined.

  3. Multiobjective optimization design of an rf gun based electron diffraction beam line

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan; Maxson, Jared

    2017-03-01

    Multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line comprised of a 100 MV /m 1.6-cell normal conducting rf (NCRF) gun, as well as a nine-cell 2 π /3 bunching cavity placed between two solenoids, have been performed. These include optimization of the normalized transverse emittance as a function of bunch charge, as well as optimization of the transverse coherence length as a function of the rms bunch length of the beam at the sample location for a fixed charge of 1 06 electrons. Analysis of the resulting solutions is discussed in terms of the relevant scaling laws, and a detailed description of one of the resulting solutions from the coherence length optimizations is given. For a charge of 1 06 electrons and final beam sizes of σx≥25 μ m and σt≈5 fs , we found a relative coherence length of Lc ,x/σx≈0.07 using direct optimization of the coherence length. Additionally, based on optimizations of the emittance as a function of final bunch length, we estimate the relative coherence length for bunch lengths of 30 and 100 fs to be roughly 0.1 and 0.2 nm /μ m , respectively. Finally, using the scaling of the optimal emittance with bunch charge, for a charge of 1 05 electrons, we estimate relative coherence lengths of 0.3, 0.5, and 0.92 nm /μ m for final bunch lengths of 5, 30 and 100 fs, respectively.

  4. Multiobjective optimization design of an rf gun based electron diffraction beam line

    Directory of Open Access Journals (Sweden)

    Colwyn Gulliford

    2017-03-01

    Full Text Available Multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line comprised of a 100  MV/m 1.6-cell normal conducting rf (NCRF gun, as well as a nine-cell 2π/3 bunching cavity placed between two solenoids, have been performed. These include optimization of the normalized transverse emittance as a function of bunch charge, as well as optimization of the transverse coherence length as a function of the rms bunch length of the beam at the sample location for a fixed charge of 10^{6} electrons. Analysis of the resulting solutions is discussed in terms of the relevant scaling laws, and a detailed description of one of the resulting solutions from the coherence length optimizations is given. For a charge of 10^{6} electrons and final beam sizes of σ_{x}≥25  μm and σ_{t}≈5  fs, we found a relative coherence length of L_{c,x}/σ_{x}≈0.07 using direct optimization of the coherence length. Additionally, based on optimizations of the emittance as a function of final bunch length, we estimate the relative coherence length for bunch lengths of 30 and 100 fs to be roughly 0.1 and 0.2  nm/μm, respectively. Finally, using the scaling of the optimal emittance with bunch charge, for a charge of 10^{5} electrons, we estimate relative coherence lengths of 0.3, 0.5, and 0.92  nm/μm for final bunch lengths of 5, 30 and 100 fs, respectively.

  5. A single-shot nonlinear autocorrelation approach for time-resolved physics in the vacuum ultraviolet spectral range

    International Nuclear Information System (INIS)

    Rompotis, Dimitrios

    2016-02-01

    In this work, a single-shot temporal metrology scheme operating in the vacuum-extreme ultraviolet spectral range has been designed and experimentally implemented. Utilizing an anti-collinear geometry, a second-order intensity autocorrelation measurement of a vacuum ultraviolet pulse can be performed by encoding temporal delay information on the beam propagation coordinate. An ion-imaging time-of-flight spectrometer, offering micrometer resolution has been set-up for this purpose. This instrument enables the detection of a magnified image of the spatial distribution of ions exclusively generated by direct two-photon absorption in the combined counter-propagating pulse focus and thus obtain the second-order intensity autocorrelation measurement on a single-shot basis. Additionally, an intense VUV light source based on high-harmonic generation has been experimentally realized. It delivers intense sub-20 fs Ti:Sa fifth-harmonic pulses utilizing a loose-focusing geometry in a long Ar gas cell. The VUV pulses centered at 161.8 nm reach pulse energies of 1.1 μJ per pulse, while the corresponding pulse duration is measured with a second-order, fringe-resolved autocorrelation scheme to be 18 ± 1 fs on average. Non-resonant, two-photon ionization of Kr and Xe and three-photon ionization of Ne verify the fifth-harmonic pulse intensity and indicate the feasibility of multi-photon VUV pump/VUV probe studies of ultrafast atomic and molecular dynamics. Finally, the extended functionally of the counter-propagating pulse metrology approach is demonstrated by a single-shot VUV pump/VUV probe experiment aiming at the investigation of ultrafast dissociation dynamics of O 2 excited in the Schumann-Runge continuum at 162 nm.

  6. Supplemental single shot femoral nerve block for total hip arthroplasty: impact on early postoperative care, pain management and lung function.

    Science.gov (United States)

    Wiesmann, T; Steinfeldt, T; Wagner, G; Wulf, H; Schmitt, J; Zoremba, M

    2014-01-01

    Peripheral regional anesthesia is beneficial in the management of postoperative pain in hip surgery, and can also reduce post-operative care unit (PACU) stay. Its opioid-sparing actions may also be beneficial for respiratory mechanics and pulmonary function. The aim of our pilot study was to evaluate the effect of a supplemental single shot femoral block for elective total hip arthroplasty on early respiratory function and postoperative management within the first 24 postoperative hours. We prospectively studied 80 patients undergoing total hip arthroplasty. Written informed consent was obtained after ethics committee approval. Forty patients were randomLy assigned to receive single shot femoral nerve block (FNB) using 15mL bupivacaine 0.25% and 20 mg clonidine while the remainder received standard treatment without nerve block (STN). Premedication and general anesthesia were standardized. Pulse oximetry saturation and spirometric lung function were measured preoperatively (baseline) and at 0.5 h, 2 h, 6 h and 24 h, after extubation breathing room air. PACU surveillance and postoperative pain therapy was standardized. Oxygen saturation and spirometry results were significantly better within the FNB group during the first six postoperative hours. Although VAS scores during the PACU stay did not significantly differ between the study groups, PACU discharge criteria were met earlier in the FNB group (116±40 min [mean±SD] vs. 152±47 min in the STN group). The FNB group exhibited significantly lower VAS scores at 6 and 24 hours. Supplemental single shot femoral nerve block for total hip arthroplasty resulted in earlier PACU discharge capability, improved lung function during the first six hours and better pain control within the first 24 postoperative hours.

  7. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  8. Transformer ratio studies for single bunch plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Massimo, F., E-mail: francesco.massimo@uniroma1.it [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); Marocchino, A. [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); Chiadroni, E.; Ferrario, M. [INFN-LNF, Frascati (Italy); Mostacci, A. [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); INFN-LNF, Frascati (Italy); Musumeci, P. [University of California, Department of Physics and Astronomy, Los Angeles (United States); Palumbo, L. [Dipartimento SBAI, “Sapienza” University of Rome, Rome (Italy); INFN-LNF, Frascati (Italy)

    2014-03-11

    In Plasma Wakefield Acceleration (PWFA) plasma oscillations are driven by ultra relativistic electron beams. The ratio of the maximum accelerating field behind the driving beam (bunch) and the maximum decelerating field inside the driving beam (bunch) is defined as Transformer Ratio, a key parameter that determines the energy gain in particle acceleration. We investigate the transformer ratio for different shapes of a single driving bunch. One dimensional, fluid, relativistic, cold plasma equations have been numerically solved. A complete map of the transformer ratio is obtained by varying: bunch shape, bunch length and density ratio. It is found that the transformer ratio critically depends on the bunch shape and on the density ratio. Moreover both in the linear as well as in the non-linear regime the theoretical limit of 2 for the transformer ratio of a single symmetric bunch can be exceeded using asymmetric bunches in the linear regime as well as symmetric bunches in nonlinear regime.

  9. Single shot fringe pattern phase demodulation using Hilbert-Huang transform aided by the principal component analysis.

    Science.gov (United States)

    Trusiak, Maciej; Służewski, Łukasz; Patorski, Krzysztof

    2016-02-22

    Hybrid single shot algorithm for accurate phase demodulation of complex fringe patterns is proposed. It employs empirical mode decomposition based adaptive fringe pattern enhancement (i.e., denoising, background removal and amplitude normalization) and subsequent boosted phase demodulation using 2D Hilbert spiral transform aided by the Principal Component Analysis method for novel, correct and accurate local fringe direction map calculation. Robustness to fringe pattern significant noise, uneven background and amplitude modulation as well as local fringe period and shape variations is corroborated by numerical simulations and experiments. Proposed automatic, adaptive, fast and comprehensive fringe analysis solution compares favorably with other previously reported techniques.

  10. Simultaneous single-shot readout of multi-qubit circuits using a traveling-wave parametric amplifier

    Science.gov (United States)

    O'Brien, Kevin

    Observing and controlling the state of ever larger quantum systems is critical for advancing quantum computation. Utilizing a Josephson traveling wave parametric amplifier (JTWPA), we demonstrate simultaneous multiplexed single shot readout of 10 transmon qubits in a planar architecture. We employ digital image sideband rejection to eliminate noise at the image frequencies. We quantify crosstalk and infidelity due to simultaneous readout and control of multiple qubits. Based on current amplifier technology, this approach can scale to simultaneous readout of at least 20 qubits. This work was supported by the Army Research Office.

  11. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  12. Photon anti bunching versus phantom anti bunching?

    International Nuclear Information System (INIS)

    Miranowicz, A.; Ekert, A.; Ekert, A.; Bajer, J.; Leonski, W.

    1997-01-01

    Photon anti bunching defined by two-time correlation functions has hitherto, to our best knowledge, been considered to constitute a unique, well defined effect. We show explicitly that this is by no means the case. We analyze two of the most famous definitions showing that both anti bunching and bunching effects according to one definition can be accompanied by arbitrary photon correlation effects according to another. As an example we discuss a model of parametric frequency conversion. (authors)

  13. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout.

    Science.gov (United States)

    Sukachev, D D; Sipahigil, A; Nguyen, C T; Bhaskar, M K; Evans, R E; Jelezko, F; Lukin, M D

    2017-12-01

    The negatively charged silicon-vacancy (SiV^{-}) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (∼250  ns) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV^{-} electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV^{-} symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV^{-} spin with 89% fidelity. Coherent control of the SiV^{-} spin with microwave fields is used to demonstrate a spin coherence time T_{2} of 13 ms and a spin relaxation time T_{1} exceeding 1 s at 100 mK. These results establish the SiV^{-} as a promising solid-state candidate for the realization of quantum networks.

  14. Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging

    Directory of Open Access Journals (Sweden)

    Margarita Zakharova

    2018-03-01

    Full Text Available Single-shot grating-based phase-contrast imaging techniques offer additional contrast modalities based on the refraction and scattering of X-rays in a robust and versatile configuration. The utilization of a single optical element is possible in such methods, allowing the shortening of the acquisition time and increasing flux efficiency. One of the ways to upgrade single-shot imaging techniques is to utilize customized optical components, such as two-dimensional (2D X-ray gratings. In this contribution, we present the achievements in the development of 2D gratings with UV lithography and gold electroplating. Absorption gratings represented by periodic free-standing gold pillars with lateral structure sizes from 5 µm to 25 µm and heights from 5 µm to 28 µm have shown a high degree of periodicity and defect-free patterns. Grating performance was tested in a radiographic setup using a self-developed quality assessment algorithm based on the intensity distribution histograms. The algorithm allows the final user to estimate the suitability of a specific grating to be used in a particular setup.

  15. Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, Valerio; Grigutis, Robertas [Dipartimento di Scienza e Alta Tecnologia, University of Insubria, Via Valleggio 11, I-22100 Como (Italy); Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); LOA, ENSTA-ParisTech, CNRS, Ecole Polytechnique, Université Paris Saclay, F-91762 Palaiseau (France); Couairon, Arnaud [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2016-07-07

    We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

  16. Generating multiple contrasts using single-shot radial T1 sensitive and insensitive steady-state imaging.

    Science.gov (United States)

    Benkert, Thomas; Bartsch, Andreas J; Blaimer, Martin; Jakob, Peter M; Breuer, Felix A

    2015-06-01

    Recently, the (Resolution Enhanced-) T1 insensitive steady-state imaging (TOSSI) approach has been proposed for the fast acquisition of T2 -weighted images. This has been achieved by balanced steady-state free precession (bSSFP) imaging between unequally spaced inversion pulses. The purpose of this work is to present an extension of this technique, considerably increasing both the efficiency and possibilities of TOSSI. A radial trajectory in combination with an appropriate view-sharing reconstruction is used. Because each projection traverses the contrast defining k-space center, several different contrasts can be extracted from a single-shot measurement. These contrasts include various T2 -weightings and T2 /T1 -weighting if an even number of inversion pulses is used, while an odd number allow the generation of several images with predefined tissue types cancelled. The approach is validated for brain and abdominal imaging at 3.0 Tesla. Results are compared with RE-TOSSI, bSSFP, and turbo spin-echo images and are shown to provide similar contrasts in a fraction of scan time. Furthermore, the potential utility of the approach is illustrated by images obtained from a brain tumor patient. Radial T1 sensitive and insensitive steady-state imaging is able to generate multiple contrasts out of one single-shot measurement in a short scan time. © 2014 Wiley Periodicals, Inc.

  17. The 'Fresh-Bunch' technique in FELs

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Yang, K.M.; Yu, L.H.

    1991-01-01

    The 'Fresh Bunch' technique is being proposed as a method of increasing the gain and power of FEL amplifiers in which the length of the optical radiation pulse is shorter than the length of the electron bunch. In multi-stage FEL, electron beam energy spread is increased by the FEL interaction in the early stages. In the 'Fresh Bunch' technique, the low energy spread of the electron beam is recovered by shifting the radiation pulse to an undisturbed part of the electron bunch, thus improving the gain and trapping fraction in later stages. A test case for the application of the Fresh Bunch method is demonstrated by numerical simulation. In this particular example we examine a subharmonically seeded VUV Free-Electron Laser. We begin with the generation of harmonic radiation, which takes place over one part of the electron bunch. Then the radiation is shifted by means of a strong dispersive section to a fresh part of the bunch for exponential amplification and tapered wiggler amplification. By starting over with a new ensemble of electrons, the energy spread introduced by the bunching in the fundamental is removed, leading to an increased gain. Furthermore, it is possible to use a much stronger seed in the fundamental without incurring the penalty of a large energy spread later on. We note that more than a single application of the 'Fresh Bunch' method may be done in a single FEL multiplier-amplifier. Thus x-ray wavelengths may be reached by successive multiplication in a chain of FEL amplifiers starting from a tunable seed laser. 5 refs., 2 figs., 2 tabs

  18. Effect of electron beam irradiation and poly(vinylpyrrolidone addition on mechanical properties of polycaprolactone with empty fruit bunch fibre (OPEFB composite

    Directory of Open Access Journals (Sweden)

    2009-04-01

    Full Text Available Biodegradable composites or green composites were prepared by melt blending technique using polycaprolactone and oil palm empty fruit bunch fibre (OPEFB. Since OPEFB is not compatible with PCL a binder, poly(vinyl pyrrolidone, (PVP was used to improve the interaction between PCL and OPEFB. The composites produced were irradiated using electron beam to improve the mechanical properties. The tensile, flexural and impact strengths of PCL/OPEFB composites were improved by addition of 1% by weight of PVP and irradiated with 10 kGy of electron beam. The FTIR spectra indicate a slight increase of frequencies at C=O peaks from 1730 to 1732 cm–1 after irradiation indicates some interaction between C=O and O–H. The surface morphology of the facture surface obtained from tensile test shows no fibre pull out indicating good adhesion between the OPEFB and PCL after addition of PVP.

  19. Simulations of the effects of a superconducting damping wiggler on a short bunched electron beam at ANKA

    Energy Technology Data Exchange (ETDEWEB)

    Gethmann, Julian; Bernhard, Axel; Blomley, Edmund; Hillenbrand, Steffen; Mueller, Anke-Susanne; Smale, Nigel [Karlsruher Institut fuer Technologie (KIT) (Germany); Zolotarev, Konstantin [Budker Institute of Nuclear Physics (Russian Federation)

    2016-07-01

    (As a part of the CLIC collaboration) A CLIC damping wiggler prototype has been installed at the ANKA synchrotron light source in order to validate the technical design of the 3 T superconducting conduction cooled wiggler and its cryostat and to cary out studies on beam dynamical aspects including collective effects. The latter one will be the main focus in this talk. Collective effects that will occur in damping rings are an issue in ANKA's short bunch operation as well. To simulate these effects the accelerator's model including its insertion device has to be very accurate. Such a model of the ANKA storage ring in short bunch operation mode has been developed in elegant. Simulations with the damping wiggler switched on and off have been performed in order to investigate effects of the wiggler on different machine parameters. These new results will be discussed with regard to the question if on the one hand the wiggler could be used for diagnostic purposes and if on the other hand the wiggler's impact on the beam dynamics is changed by the collective effects.

  20. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    Science.gov (United States)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  1. Effects of emittance and space-charge in femtosecond bunch compression

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2008-01-01

    Ultrashort electron bunches of the order of <100fs are essential for the study of ultrafast reactions and phenomena by means of time-resolved pump-probe experiments. In order to generate such an electron bunch, the effects of emittance, space-charge (SC) and coherent synchrotron radiation (CSR) on the bunch length in a femtosecond magnetic bunch compressor were studied theoretically. It was observed that the bunch length is dominated by the emittance, SC and CSR effects when the electron bunch is compressed into a femtosecond electron bunch. The increases in bunch length due to the transverse emittance, SC and CSR effects in the bunch compressor were 1.7 fs/mm mrad, 107 fs/nC and 72 fs/nC, respectively. Finally, the simulated bunch length was compared with the experimental results.

  2. Short bunch wake potentials for a chain of TESLA cavities

    International Nuclear Information System (INIS)

    Novokhatski, Alexander; Mosnier, Alban

    2014-01-01

    The modification of wake fields from a single cavity to a quasi-periodic structure of cavities is of great concern, especially for applications using very short bunches. We extend our former study (Novokhatski, 1997 [1]). A strong modification of wake fields along a train of cavities was clearly found for bunch lengths lower than 1 mm. In particular, the wakes induced by the bunch, as it proceeds down the successive cavities, decrease in amplitude and become more linear around the bunch center, with a profile very close to the integral of the charge density. The loss factor, decreasing also with the number of cells, becomes independent of bunch length for very short bunches and tends asymptotically to a finite value. This nice behavior of wake fields for short bunches presents good opportunity for application of very short bunches in Linear Colliders and X-ray Free Electron Lasers

  3. Application accelerator system having bunch control

    International Nuclear Information System (INIS)

    Wang, D.; Krafft, G.A.

    1999-01-01

    An application accelerator system for monitoring the gain of a free electron laser is disclosed. Coherent Synchrotron Radiation (CSR) detection techniques are used with a bunch length monitor for ultra short, picosec to several tens of femtosec, electron bunches. The monitor employs an application accelerator, a coherent radiation production device, an optical or beam chopping device, an infrared radiation collection device, a narrow-banding filter, an infrared detection device, and a control. 1 fig

  4. Application accelerator system having bunch control

    Science.gov (United States)

    Wang, Dunxiong; Krafft, Geoffrey Arthur

    1999-01-01

    An application accelerator system for monitoring the gain of a free electron laser. Coherent Synchrotron Radiation (CSR) detection techniques are used with a bunch length monitor for ultra short, picosec to several tens of femtosec, electron bunches. The monitor employs an application accelerator, a coherent radiation production device, an optical or beam chopping device, an infrared radiation collection device, a narrow-banding filter, an infrared detection device, and a control.

  5. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  6. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Blood Bupivacaine Concentrations After a Combined Single-Shot Sciatic Block and a Continuous Femoral Nerve Block in Pediatric Patients: A Prospective Observational Study.

    Science.gov (United States)

    Suresh, Santhanam; De Oliveira, Gildasio S

    2017-05-01

    We evaluated blood bupivacaine concentrations in children having a single-shot sciatic and continuous femoral blocks after anterior cruciate ligament repair. Dried blood spot samples were analyzed for bupivacaine levels at 0, 5, 15, 30, 60, and 120 minutes and 4, 24, and 48 hours. The highest 99% upper confidence interval limit was 135 ng/mL at the 4-hour evaluation point. The 99% upper confidence interval was below potentially toxic levels (1500 ng/mL) across all sampling times. The risk of local anesthetic toxicity in pediatric patients receiving single-shot sciatic and continuous femoral nerve blocks is very low.

  8. Generation and measurement of velocity bunched ultrashort bunch of pC charge

    Directory of Open Access Journals (Sweden)

    X. H. Lu

    2015-03-01

    Full Text Available In this paper, we discuss the velocity compression in a short rf linac of an electron bunch from a rf photoinjector operated in the blowout regime. Particle tracking simulations shows that with a beam charge of 2 pC an ultrashort bunch duration of 16 fs can be obtained at a tight longitudinal focus downstream of the linac. A simplified coherent transition radiation (CTR spectrum method is developed to enable the measurement of ultrashort (sub-50 fs bunches at low bunch energy (5 MeV and low bunch charges (<10  pC. In this method, the ratio of the radiation energy selected by two narrow bandwidth filters is used to estimate the bunch length. The contribution to the coherent form factor of the large transverse size of the bunch suppresses the radiation signal significantly and is included in the analysis. The experiment was performed at the UCLA Pegasus photoinjector laboratory. The measurement results show bunches of sub-40 fs with 2 pC of charge well consistent with the simulation using actual experimental conditions. These results open the way to the generation of ultrashort bunches with time-duration below 10 fs once some of the limitations of the setup (rf phase jitter, amplitude instability and low field in the gun limited by breakdown are corrected.

  9. Bunch Compression Stability Dependence on RF Parameters

    CERN Document Server

    Limberg, T

    2005-01-01

    In present designs for FEL's with high electron peak currents and short bunch lengths, higher harmonic RF systems are often used to optimize the final longitudinal charge distributions. This opens degrees of freedom for the choice of RF phases and amplitudes to achieve the necessary peak current with a reasonable longitudinal bunch shape. It had been found empirically that different working points result in different tolerances for phases and amplitudes. We give an analytical expression for the sensitivity of the compression factor on phase and amplitude jitter for a bunch compression scheme involving two RF systems and two magnetic chicanes as well numerical results for the case of the European XFEL.

  10. Multi-bunch Feedback Systems

    International Nuclear Information System (INIS)

    Lonza, M; Schmickler, H

    2014-01-01

    Coupled-bunch instabilities excited by the interaction of the particle beam with its surroundings can seriously limit the performance of circular particle accelerators. These instabilities can be cured by the use of active feedback systems based on sensors capable of detecting the unwanted beam motion and actuators that apply the feedback correction to the beam. Advances in electronic technology now allow the implementation of feedback loops using programmable digital systems. Besides important advantages in terms of flexibility and reproducibility, digital systems open the way to the use of novel diagnostic tools and additional features. We first introduce coupled-bunch instabilities, analysing the equation of motion of charged particles and the different modes of oscillation of a multi-bunch beam, showing how they can be observed and measured. Different types of feedback systems will then be presented as examples of real implementations that belong to the history of multi-bunch feedback systems. The main components of a feedback system and the related issues will also be analysed. Finally, we shall focus on digital feedback systems, their characteristics, and features, as well as on how they can be concretely exploited for both the optimization of feedback performance and for beam dynamics studies

  11. Multiobjective optimizations of a novel cryocooled dc gun based ultrafast electron diffraction beam line

    Directory of Open Access Journals (Sweden)

    Colwyn Gulliford

    2016-09-01

    Full Text Available We present the results of multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed for three different sample radii: 50, 100, and 200  μm, for two final bunch charges: 10^{5} electrons (16 fC and 10^{6} electrons (160 fC. Example optimal solutions are analyzed, and the effects of disordered induced heating estimated. In particular, a relative coherence length of L_{c,x}/σ_{x}=0.27  nm/μm was obtained for a final bunch charge of 10^{5} electrons and final bunch length of σ_{t}≈100  fs. For a final charge of 10^{6} electrons the cryogun produces L_{c,x}/σ_{x}≈0.1  nm/μm for σ_{t}≈100–200  fs and σ_{x}≥50  μm. These results demonstrate the viability of using genetic algorithms in the design and operation of ultrafast electron diffraction beam lines.

  12. Software development for Indus-1 bunch filling pattern measurement

    International Nuclear Information System (INIS)

    Yadav, Surendra; Holikatti, Anil C.; Puntambekar, T.A.

    2011-01-01

    Indus-1 is a 450 MeV synchrotron radiation source operational at RRCAT Indore. In Indus-1 storage ring, electrons are stored in two bunches. The distribution of beam current in these two bunches is termed as bunch filling pattern. In Indus-1, it is desirable to have symmetric bunch filling pattern for its optimum performance. This paper describes the development of software for bunch filling pattern measurement of Indus-1. This software measures the current distribution of the electron bunches circulating in the storage ring. To measure bunch currents wall current monitor (WCM) installed in the Indus-1 storage ring is used. Using a 500 MHz digital storage oscilloscope as a high-speed digitizer and online data processing by the developed software, measurement of online bunch filling pattern was achieved. This software has helped Indus operation crew to achieve desired bunch current symmetry in the Indus-1 storage ring. The software has the provision to store the online bunch current symmetry into a Microsoft-excel file which can be used for further analysis. Using this software, up to 99% bunch filling symmetry has been achieved by Indus operation crew. (author)

  13. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposure

    Czech Academy of Sciences Publication Activity Database

    Khorsand, A.R.; Sobierajski, R.; Louis, E.; Bruijn, S.; van Hattum, E.D.; van de Kruijs, R.W.E.; Jurek, M.; Klinger, D.; Pelka, J. B.; Juha, Libor; Burian, Tomáš; Chalupský, Jaromír; Cihelka, Jaroslav; Hájková, Věra; Vyšín, Luděk; Jastrow, U.; Stojanovic, N.; Toleikis, S.; Wabnitz, H.; Tiedtke, K.; Sokolowski-Tinten, K.; Shymanovich, U.; Krzywinski, J.; Hau-Riege, S.; London, R.; Gleeson, A.; Gullikson, E.M.; Bijkerk, F.

    2010-01-01

    Roč. 18, č. 2 (2010), 700-712 ISSN 1094-4087 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : laser damage * thermal effects * multilayers * optical design and fabrication * free-electron lasers Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.749, year: 2010

  14. Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Yiping, Lu [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Hui, Liu [MR Collaboration NE Asia, Siemens Healthcare, Siemens Ltd., China, Shanghai 201318 (China); Kun, Zhou [MR PLM APPL, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen 518057 (China); Daoying, Geng, E-mail: GengdaoyingGDY@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Bo, Yin, E-mail: yinbo7@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China)

    2014-07-15

    Purpose: The purpose of this study is to compare BLADE diffusion-weighted imaging (DWI) with single-shot echo planar imaging (EPI) DWI on the aspects of feasibility of imaging the sellar region and image quality. Methods: A total of 3 healthy volunteers and 52 patients with suspected lesions in the sellar region were included in this prospective intra-individual study. All exams were performed at 3.0 T with a BLADE DWI sequence and a standard single-shot EP-DWI sequence. Phantom measurements were performed to measure the objective signal-to-noise ratio (SNR). Two radiologists rated the image quality according to the visualisation of the internal carotid arteries, optic chiasm, pituitary stalk, pituitary gland and lesion, and the overall image quality. One radiologist measured lesion sizes for detecting their relationship with the image score. Results: The SNR in BLADE DWI sequence showed no significant difference from the single-shot EPI sequence (P > 0.05). All of the assessed regions received higher scores in BLADE DWI images than single-shot EP-DWI.

  15. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori

    2016-01-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10 13 photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO 2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  16. Ankle Block vs Single-Shot Popliteal Fossa Block as Primary Anesthesia for Forefoot Operative Procedures: Prospective, Randomized Comparison.

    Science.gov (United States)

    Schipper, Oliver N; Hunt, Kenneth J; Anderson, Robert B; Davis, W Hodges; Jones, Carroll P; Cohen, Bruce E

    2017-11-01

    Postoperative pain is often difficult to control with oral medications, requiring large doses of opioid analgesia. Regional anesthesia may be used for primary anesthesia, reducing the need for general anesthetic and postoperative pain medication requirements in the immediate postoperative period. The purpose of this study was to compare the analgesic effects of an ankle block (AB) to a single-shot popliteal fossa block (PFB) for patients undergoing orthopedic forefoot procedures. All patients having elective outpatient orthopedic forefoot procedures were invited to participate in the study. Patients were prospectively randomized to receive either an ultrasound-guided AB or PFB by a board-certified anesthesiologist prior to their procedure. Intraoperative conversion to general anesthesia and postanesthesia care unit (PACU) opioid requirements were recorded. Postoperative pain was assessed using the visual analog scale (VAS) at regular time intervals until 8 am on postoperative day (POD) 2. Patients rated the effectiveness of the block on a 1 to 5 scale, with 5 being very effective. A total of 167 patients participated in the study with 88 patients (53%) receiving an AB and 79 (47%) receiving a single-shot PFB. There was no significant difference in the rate of conversion to general anesthesia between the 2 groups (13.6% [12/88] AB vs 12.7% [10/79] PFB). PACU morphine requirements and doses were significantly reduced in the PFB group ( P = .004) when compared to the AB group. The VAS was also significantly lower for the PFB patients at 10 pm on POD 0 (4.6 vs 1.6, P PFB 10.1%, P = .51) and there were no significant differences in residual sensory paresthesias (AB 2.3% [2/88] vs PFB 5.1% [4/79], P = .29), motor loss (0% vs 0%), or block site pain and/or erythema (AB 6.9% [6/88] vs PFB 5.1% [4/79], P = .44). The analgesic effect of the PFB lasted significantly longer when compared to the ankle block (AB 14.5 hours vs PFB 20.9 hours, P PFB 4.82/5, P = .68). Regional

  17. Comparing SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Curry, Matthew; Carr, Stephen; Mounce, Andrew; Jock, Ryan; Sharma, Peter; Bureau-Oxton, Chloe; Rudolph, Martin; Hardin, Terry; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will compare two amplifiers based on single-transistor circuits implemented with silicon germanium heterojunction bipolar transistors. Both amplifiers provide gain at low power levels, but the dynamics of each circuit vary significantly. We will explore the gain mechanisms, linearity, and noise of each circuit and explain the situations in which each amplifier is best used. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  18. The value of single-shot black-blood MR imaging for mapping of the coronary arteries: a comparison of four different orientations during breath-holding and free breathing.

    NARCIS (Netherlands)

    Holland, A.E.; Engelbrecht, M.R.W.; Barentsz, J.O.; Heijstraten, F.M.J.; Goldfarb, J.W.

    2002-01-01

    The value of ECG-gated single-shot black-blood MR imaging for rapid visualization of the origin and course of the coronary arteries was investigated. The study population included 28 patients with known or suspected cardiac disease. ECG-gated single-shot black-blood MR acquisitions were acquired in

  19. Fast and robust automatic calibration for single-shot dual-wavelength digital holography based on speckle displacements.

    Science.gov (United States)

    Khodadad, Davood; Bergström, Per; Hällstig, Emil; Sjödahl, Mikael

    2015-06-01

    The objective of this paper is to describe a fast and robust automatic single-shot dual-wavelength holographic calibration method that can be used for online shape measurement applications. We present a model of the correction in two terms for each lobe, one to compensate the systematic errors caused by off-axis angles and the other for the curvature of the reference waves, respectively. Each hologram is calibrated independently without a need for an iterative procedure or information of the experimental set-up. The calibration parameters are extracted directly from speckle displacements between different reconstruction planes. The parameters can be defined as any fraction of a pixel to avoid the effect of quantization. Using the speckle displacements, problems associated with phase wrapping is avoided. The procedure is shown to give a shape accuracy of 34 μm using a synthetic wavelength of 1.1 mm for a measurement on a cylindrical test object with a trace over a field of view of 18  mm×18  mm.

  20. Single-shot T1 mapping of the corpus callosum: A rapid characterization of fiber bundle anatomy

    Directory of Open Access Journals (Sweden)

    Sabine eHofer

    2015-05-01

    Full Text Available Using diffusion-tensor MRI and fiber tractography the topographic organization of the corpus callosum (CC has been described to comprise 5 segments with fibers projecting into prefrontal (I, premotor and supplementary motor (II, primary motor (III, and primary sensory areas (IV, as well as into parietal, temporal, and occipital cortical areas (V. In order to more rapidly characterize the underlying anatomy of these segments, this study used a novel single-shot T1 mapping method to quantitatively determine T1 relaxation times in the human CC. A region-of-interest analysis revealed a tendency for the lowest T1 relaxation times in the genu and the highest T1 relaxation times in the somatomotor region of the CC. This observation separates regions dominated by myelinated fibers with large diameters (somatomotor area from densely packed smaller axonal bundles (genu with less myelin. The results indicate that characteristic T1 relaxation times in callosal profiles provide an additional means to monitor differences in fiber anatomy, fiber density, and gray matter in respective neocortical areas. In conclusion, rapid T1 mapping allows for a characterization of the axonal architecture in an individual CC in less than 10 s. The approach emerges as a valuable means for studying neocortical brain anatomy with possible implications for the diagnosis of neurodegenerative processes.

  1. Anti-spoof touchless 3D fingerprint recognition system using single shot fringe projection and biospeckle analysis

    Science.gov (United States)

    Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2017-08-01

    Fingerprint is a unique, un-alterable and easily collected biometric of a human being. Although it is a 3D biological characteristic, traditional methods are designed to provide only a 2D image. This touch based mapping of 3D shape to 2D image losses information and leads to nonlinear distortions. Moreover, as only topographic details are captured, conventional systems are potentially vulnerable to spoofing materials (e.g. artificial fingers, dead fingers, false prints, etc.). In this work, we demonstrate an anti-spoof touchless 3D fingerprint detection system using a combination of single shot fringe projection and biospeckle analysis. For fingerprint detection using fringe projection, light from a low power LED source illuminates a finger through a sinusoidal grating. The fringe pattern modulated because of features on the fingertip is captured using a CCD camera. Fourier transform method based frequency filtering is used for the reconstruction of 3D fingerprint from the captured fringe pattern. In the next step, for spoof detection using biospeckle analysis a visuo-numeric algorithm based on modified structural function and non-normalized histogram is proposed. High activity biospeckle patterns are generated because of interaction of collimated laser light with internal fluid flow of the real finger sample. This activity reduces abruptly in case of layered fake prints, and is almost absent in dead or fake fingers. Furthermore, the proposed setup is fast, low-cost, involves non-mechanical scanning and is highly stable.

  2. Near field flow characteristics of the Bjork-Shiley Monostrut valve in a modified single shot valve chamber.

    Science.gov (United States)

    Manning, Keefe B; Przybysz, T Michael; Fontaine, Arnold A; Tarbell, John M; Deutsch, Steven

    2005-01-01

    In certain mechanical heart valves, cavitation has been shown to develop during closure and rebound, leading to valve damage, blood damage, and strokes. Whereas it is uncertain what causes mechanical heart valve related strokes, some evidence suggests that stable bubbles may be the culprits. Previous work has indicated that vortex cavitation may contribute to stable bubble growth. Therefore, in an effort to understand the vortex cavitation, laser Doppler velocimetry data are collected in a plane parallel to and 3 mm away from the major orifice during closure and rebound of a Bjork-Shiley Monostrut mechanical heart valve. A modified single shot chamber is used that incorporates a more realistic near valve geometry than those used in previous studies. The results show the formation of a vortex during closure, which intensifies during rebound and dissipates during the final closing cycle. A regurgitant jet with mean velocities up to 3 m/s through the clearance gap of the valve provides energy to the vortex. During the final closing cycle, the vortex breaks up into asymmetrical, small scale flow patterns. This study provides further evidence that stable bubble formation may stem from the intense vortex cavitation occurring during valve closure and rebound.

  3. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  4. Poloxamer 407-chitosan grafted thermoresponsive hydrogels achieve synchronous and sustained release of antigen and adjuvant from single-shot vaccines.

    Science.gov (United States)

    Bobbala, Sharan; Gibson, Blake; Gamble, Allan B; McDowell, Arlene; Hook, Sarah

    2018-03-02

    Sustained release vaccine delivery systems may enhance the immunogenicity of subunit vaccines and reduce the need for multiple vaccinations. The aim of this study was to develop a thermoresponsive hydrogel using poloxamer 407-chitosan (CP) grafted copolymer as a delivery system for single-shot sustained release vaccines. The CP copolymer was synthesized using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) chemistry. The CP copolymer was a free flowing solution at ambient temperature and transformed rapidly into a gel at body temperature. The hydrogels were loaded with vaccine antigen and adjuvants or the vaccine components were encapsulated in poly (lactic-co-glycolic acid) nanoparticles (PLGA-NP) in order to ensure synchronous release. The CP hydrogels were stable for up to 18 days in vitro. Release of both nanoparticles and the individual components was complete, with release of the individual components being modulated by incorporation into nanoparticles. In vivo, a single dose of CP hydrogel vaccine induced strong, long lasting, cellular and humoral responses that could protect against the development of tumors in a murine melanoma model. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    Energy Technology Data Exchange (ETDEWEB)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan)

    1999-04-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  6. LITGS: a new technique for single shot temperature and fuel concentration measurements in turbulent combusting environments

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, Roberta; Giorgi, M. [ENEA, Centro Ricerche Frascati, Frascati, RM (Italy). Dipt. Innovazione; De Risi, A.; Laforgia, D. [Lecce Univ., Lecce (Italy). Dipt. di Ingegneria dell' Innovazione

    1999-07-01

    In the present study the possibility to apply time resolved Laser Induced Thermal Grating Spectroscopy (LITGS) to detect fuel concentration and temperature in mixtures and flames at atmospheric pressure or higher is investigated. The resonant IR single photon absorption of two short pulse pump beams is used to initially generate a population grating, decaying into a thermal grating due to relaxation processes in the gas mixture. The thermal grating evolution is followed by monitoring the scattered signal of a cw visible probe beam after the end of the pump pulse. The use of the IR optical transition of diesel fuel assured a high species selectivity and a negligible influence of the visible emission background due to the presence of electronically excited species in flames. Fuel concentration and temperature measurements in a pressurized cell, with pressure ranging between 0.1 an 1.5 MPa, and in a diffusion turbulent flame generated by a burner feed with diesel fuel operating at atmospheric pressure are presented. The experimental investigation shows that LITGS signal increase linearly with gas density. This characteristic makes LITGS a very interesting technique for fuel distribution and temperature measurements in hostile (high-pressure and turbulent flow) environments. Detection limit for diesel fuel at atmospheric pressure is found to be about 40 ppm and it decreases with the increase of the pressure. The low detection limit which can be reached makes this technique suitable also for monitoring minor species and radicals. [Italian] Nel presente studio si investiga la possibilita' di applicare la tecnica LITGS (Laser Induced Thermal Grating Spectroscopy) per misurare la concentrazione e la temperatura di carburante in miscele e fiamme a pressiona atmosferica o superiore. L'assorbimento risonante di un singolo fotone IR proveniente da uno dei due laser impulsati di pompa e' utilizzato per generare inizialmente un reticolo di popolazione, che decade

  7. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences; Urografia por resonancia magnetic en pediatria: utilizacion de las secuencias ultrarrapidas single shot en eco del espin

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.; Martin, J.; Duran, C. [Unidad de Diagnostico por la Imagen de Alta Tecnologia (UDIAT). Sabadell (Spain); Rigol, S.; Rojo, J. C. [Corporacion Sanatiaria Parc Tauli. Sabadell (Spain)

    1999-07-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE{sub e}f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE{sub e}f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs.

  8. Short-bunch generation from an rf photoinjector with injection phase compensation

    Directory of Open Access Journals (Sweden)

    F. H. Chao

    2015-05-01

    Full Text Available A radio-frequency photoinjector is widely used for generating picosecond-femtosecond electron bunches. During particle acceleration, the electron bunch shape varies under the influence of both the acceleration fields and space charge fields. To restore a distorted electron bunch, we propose an injection phase compensation technique for the electrons by illuminating the photocathode with a pulse-front-corrected laser pulse. Using an S-band 1.6-cell photoinjector as an example, our study shows that the proposed technique can generate nearly undistorted electron bunches up to a bunch rate of a few hundred terahertz.

  9. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

    International Nuclear Information System (INIS)

    Okur, A.; Kantarci, M.; Karaca, L.; Yildiz, S.; Sade, R.; Pirimoglu, B.; Keles, M.; Avci, A.; Çankaya, E.; Schmitt, P.

    2016-01-01

    Aim: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. Materials and methods: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. Results: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. Conclusion: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. - Highlights: • Close monitoring and early intervention in hemodialysis fistulas may prolong longevity fistulas. • DopplerUS, contrast enhanced CT and MRI are using assessment of hemodialysis fistulas. • QISS nonenhanced MR angiography represents an alternative for assessment of hemodialysis fistulas.

  10. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  11. Low energy spread 100 MeV-1 GeV electron bunches from laser wakefield acceleration at LOASIS

    International Nuclear Information System (INIS)

    Geddes, C.G.R.; Esarey, E.; Michel, P.; Nagler, B.; Nakamura, K.; Plateau, G.R.; Schroeder, C.B.; Shadwick, B.A.; Toth, Cs.; Van Tilborg, J.; Leemans, W.P.; Hooker, S.M.; Gonsalves, A.J.; Michel, E.; Cary, J.R.; Bruhwiler, D.

    2006-01-01

    Experiments at the LOASIS laboratory of LBNL recently demonstrated production of 100 MeV electron beams with low energy spread and low divergence from laser wakefield acceleration. The radiation pressure of a 10 TW laser pulse guided over 10 diffraction ranges by a plasma density channel was used to drive an intense plasma wave (wakefield), producing acceleration gradients on the order of 100 GV/m in a mm-scale channel. Beam energy has now been increased from 100 to 1000 MeV by using a cm-scale guiding channel at lower density, driven by a 40TW laser, demonstrating the anticipated scaling to higher beam energies. Particle simulations indicate that the low energy spread beams were produced from self trapped electrons through the interplay of trapping, loading, and dephasing. Other experiments and simulations are also underway to control injection of particles into the wake, and hence improve beam quality and stability further

  12. KEKB bunch feedback systems

    Energy Technology Data Exchange (ETDEWEB)

    Tobiyama, M.; Kikutani, E. [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1996-08-01

    Design and the present status of the bunch by bunch feedback systems for KEKB rings are shown. The detection of the bunch oscillation are made with the phase detection for longitudinal plane, the AM/PM method for transverse plane. Two GHz component of the bunch signal which is extracted with an analog FIR filter is used for the detection. Hardware two-tap FIR filter systems to shift the phase of the oscillation by 90deg will be used for the longitudinal signal processing. The same system will be used with no filtering but with only digital delay for transverse system. The candidate for the kicker and the required maximum power are also estimated. (author)

  13. Function of bunching segment in multi-cell RF gun

    International Nuclear Information System (INIS)

    Yang Xingfan; Xu Zhou Liu Xisan

    2001-01-01

    With a bunching segment and a shortened first cell, the 4 + 1/2 cell RF gun produced in CAEP has been proved experimentally to be effective in reducing electron back bombardment. The analysis of the electric field distribution and electron motion in bunching segment of multi-cell RF gun is presented. The electron capture efficiency and electron trajectory with different initial phase are calculated using Runge-Kutta method. The function of the bunching segment is discussed. The calculated parameters of the 4 + 1/2 cell RF gun agree well with the experimental results

  14. Micro-bunching diagnostics for the IFEL by coherent transition radiation

    International Nuclear Information System (INIS)

    Liu, Y.; Cline, D.B.

    1996-10-01

    Here, we propose an effective method for detecting micro-bunching effects (10 fs bunch length) produced by the IFEL interaction, by measuring the CTR spectrum. The pre-bunching of an initially energy- modulated c- beam passing through a wiggler (IFEL interaction) is studied. Simulation shows that more than 40% of electrons are pre- bunched in the micro-bunches. The longitudinal distribution of an optically pre-bunched beam is Fourier analyzed to find the dominant harmonics contributing to the CTR. The CTR spectrum is calculated analytically for the IFEL situation. A detection system has been built to demonstrate this technique

  15. Performance of the transverse coupled-bunch feedback system in the SRRC

    International Nuclear Information System (INIS)

    Hsu, K.T.; Kuo, C.C.; Kuo, C.H.; Lin, K.K.; Ueng, T.S.; Weng, W.T.

    1996-01-01

    A transverse feedback system has been implemented and commissioned in the SRRC storage ring to suppress transverse coupled-bunch oscillations of the electron beam. The system includes transverse oscillation detectors, notch filter, baseband quadrature processing circuitry, power amplifiers, and kickers. To control a large number of transverse coupled-bunch modes, the system is broad-band, bunch-by- bunch in nature. Because the system is capable of bunch-by-bunch correction, it can also be useful for suppressing instabilities introduced by ions. The sextupole strength was then reduced to improve dynamic aperture and hence lifetime of the storage ring

  16. Design, construction and measurements of an alpha magnet as a solution for compact bunch compressor for the electron beam from Thermionic RF Gun

    Science.gov (United States)

    Rajabi, A.; Jazini, J.; Fathi, M.; Sharifian, M.; Shokri, B.

    2018-03-01

    The beam produced by a thermionic RF gun has wide energy spread that makes it unsuitable for direct usage in photon sources. Here in the present work, we optimize the extracted beam from a thermionic RF gun by a compact economical bunch compressor. A compact magnetic bunch compressor (Alpha magnet) is designed and constructed. A comparison between simulation results and experimental measurements shows acceptable conformity. The beam dynamics simulation results show a reduction of the energy spread as well as a compression of length less than 1 ps with 2.3 mm-mrad emittance.

  17. Hollow bunches production

    CERN Document Server

    Hancock, S

    2017-01-01

    Hollow bunches address the issue of high-brightnessbeams suffering from transverse emittance growth in a strongspace charge regime. During the Proton Synchrotron (PS)injection plateau, the negative space charge tune shift canpush the beam onto theQy=6integer resonance. Modify-ing the longitudinal bunch profile in order to reduce the peakline charge density alleviates the detrimental impact of spacecharge. To this end we first produce longitudinally hollowphase space distributions in the PS Booster by exciting aparametric resonance with the phase loop feedback system.These inherently flat bunches are then transferred to the PS,where the beam becomes less prone to the emittance growthcaused by the integer resonance.During the late 2016 machine development sessions inthe PS Booster we profited from solved issues from 2015and managed to reliably extract hollow bunches of1.3eVsmatched longitudinal area. Furthermore, first results to cre-ate hollow bunches with larger longitudinal emittances to-wards the LHC Inject...

  18. Interaction of an ion bunch with a plasma slab

    Energy Technology Data Exchange (ETDEWEB)

    Krasovitskiy, V. B., E-mail: krasovit@mail.ru [Russian Academy of Sciences, Keldysh Institute of Applied Mathematics (Russian Federation); Turikov, V. A. [Peoples’ Friendship University of Russia (Russian Federation)

    2016-11-15

    Charge neutralization of a short ion bunch passing through a plasma slab is studied by means of numerical simulation. It is shown that a fraction of plasma electrons are trapped by the bunch under the action of the collective charge separation field. The accelerated electrons generated in this process excite beam−plasma instability, thereby violating the trapping conditions. The process of electron trapping is also strongly affected by the high-frequency electric field caused by plasma oscillations at the slab boundaries. It is examined how the degree of charge neutralization depends on the parameters of the bunch and plasma slab.

  19. Bunch-by-bunch feedback for PEP II

    International Nuclear Information System (INIS)

    Oxoby, G.; Claus, R.; Eisen, N.; Fox, J.; Hindi, H.; Hoeflich, J.; Olsen, J.; Sapozhnikov, L.; Linscott, I.

    1993-01-01

    The proposed PEP II B factory at SLAC requires a feedback to damp out longitudinal synchrotron oscillations. A time domain, downsampled, bunch-by-bunch feedback system in which each bunch is treated as an oscillator being driven by disturbances from other bunches is presented as we review the evolution of the system design. Results from a synchrotron oscillation damping experiment conducted at the SLAC/SSRL/SPEAR ring are also presented in this paper

  20. CERN: The best of the bunch

    International Nuclear Information System (INIS)

    Gagliardi, F.

    1992-01-01

    As other factors governing the electron-positron collision rate in CERN's LEP 27-kilometre storage ring reach their limit, one way of coaxing the collision rate higher is to increase the number of bunches stored in the ring

  1. Stability condition for the drive bunch in a collinear wakefield accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Baturin, S. S.; Zholents, A.

    2018-03-01

    The beam breakup instability of the drive bunch in the structure-based collinear wakefield accelerator is considered and a stabilizing method is proposed. The method includes using the specially designed beam focusing channel, applying the energy chirp along the electron bunch, and keeping energy chirp constant during the drive bunch deceleration. A stability condition is derived that defines the limit on the accelerating field for the witness bunch.

  2. Bunch compression for an FEL at NLCTA

    International Nuclear Information System (INIS)

    Zimmermann, F.

    1997-04-01

    As part of the design effort for a free electron laser driven by the Next Linear Collider Test Accelerator (NLCTA), the author reports studies of bunch-length compression utilizing the existing infrastructure and hardware. In one possible version of the NLCTA FEL, bunches with 900-microm FWHM length, generated by an S-band photo-injector, would be compressed to an rms length of 60--120 microm before entering the FEL undulator. It is shown that, using the present magnetic chicane, the bunch compression is essentially straightforward, and that almost all emittance-diluting effects, e.g. wakefields, chromaticity, or space charge in the bending magnets, are small. The only exception to this finding is the predicted increase of the horizontal emittance due to coherent synchrotron radiation (CSR). Estimates based on existing theories of coherent synchrotron radiation suggest a tripling or quadrupling of the initial emittance, which seems to preclude bunch compression during regular FEL operation. Serendipitously, the magnitude of the predicted emittance growth would, on the other hand, make the NLCTA chicane an excellent tool for measuring the effects of coherent synchrotron radiation. This will be of considerable interest to many future projects, in particular to the Linac Coherent Light Source (LCLS). As an aside, it is shown that coherent synchrotron radiation in a bending magnet gives rise to a minimum possible bunch length, which is very reminiscent of the Oide limit on the vertical spot size at the interaction point of a linear collider

  3. Radiation damage to amorphous carbon thin films irradiated by multiple 46.9 nm laser shots below the single-shot damage threshold

    Czech Academy of Sciences Publication Activity Database

    Juha, Libor; Hájková, Věra; Chalupský, Jaromír; Vorlíček, Vladimír; Ritucci, A.; Reale, A.; Zuppella, P.; Störmer, M.

    2009-01-01

    Roč. 105, č. 9 (2009), 093117/1-093117/3 ISSN 0021-8979 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : single-shot damage threshold * multiple-shot exposure damage * amorphous carbon * radiation erosion * capillary-discharge XUV laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.072, year: 2009

  4. Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

    Energy Technology Data Exchange (ETDEWEB)

    Litos, M.D.; Bionta, M.R.; Dolgashev, V.A.; England, R.J.; Fritz, D.; Gilevich, S.; Hering, Ph.; Hogan, M.J.; /SLAC

    2011-08-19

    Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

  5. Angle-resolved spectral Fabry-Pérot interferometer for single-shot measurement of refractive index dispersion over a broadband spectrum

    Science.gov (United States)

    Dong, J. T.; Ji, F.; Xia, H. J.; Liu, Z. J.; Zhang, T. D.; Yang, L.

    2018-01-01

    An angle-resolved spectral Fabry-Pérot interferometer is reported for fast and accurate measurement of the refractive index dispersion of optical materials with parallel plate shape. The light sheet from the wavelength tunable laser is incident on the parallel plate with converging angles. The transmitted interference light for each angle is dispersed and captured by a 2D sensor, in which the rows and the columns are used to simultaneously record the intensities as a function of wavelength and incident angle, respectively. The interferogram, named angle-resolved spectral intensity distribution, is analyzed by fitting the phase information instead of finding the fringe peak locations that present periodic ambiguity. The refractive index dispersion and the physical thickness can be then retrieved from a single-shot interferogram within 18 s. Experimental results of an optical substrate standard indicate that the accuracy of the refractive index dispersion is less than 2.5  ×  10-5 and the relative uncertainty of the thickness is 6  ×  10-5 mm (3σ) due to the high stability and the single-shot measurement of the proposed system.

  6. Infrared-spectroscopic single-shot laser mapping ellipsometry: Proof of concept for fast investigations of structured surfaces and interactions in organic thin films

    Science.gov (United States)

    Furchner, Andreas; Kratz, Christoph; Gkogkou, Dimitra; Ketelsen, Helge; Hinrichs, Karsten

    2017-11-01

    We present a novel infrared-spectroscopic laser mapping ellipsometer based on a single-shot measurement concept. The ellipsometric set-up employs multiple analyzers and detectors to simultaneously measure the sample's optical response under different analyzer azimuths. An essential component is a broadly tunable quantum cascade laser (QCL) covering the important marker region of 1800-1540 cm-1. The ellipsometer allows for fast single-wavelength as well as spectroscopic studies with thin-film sensitivity at temporal resolutions of 60 ms per wavelength. We applied the single-shot mapping ellipsometer for the characterization of metal-island enhancement surfaces as well as of molecular interactions in organic thin films. In less than 3 min, a linescan with 1600 steps revealed profile and infrared-enhancement properties of a gradient gold-island film for sensing applications. Spectroscopic measurements were performed to probe the amide I band of thin films of poly(N-isopropylacrylamide) [PNIPAAm], a stimuli-responsive polymer for bioapplications. The QCL spectra agree well with conventional FT-IR ellipsometric results, showing different band components associated with hydrogen-bond interactions between polymer and adsorbed water. Multi-wavelength ellipsometric maps were used to analyze homogeneity and surface contaminations of the polymer films.

  7. Diffusion-weighted MRI of the cervical spinal cord using a single-shot fast spin-echo technique: findings in normal subjects and in myelomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K.; Katase, S.; Fujikawa, A.; Hachiya, J. [Department of Radiology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, 181-8611, Tokyo (Japan); Kanazawa, H. [Toshiba Corporation, 1-1-1 Shibaura, Minato-ku, 105-8001, Tokyo (Japan); Yodo, K. [Toshiba Medical Systems, 3-26-5 Hongo, Bunkyo-ku, 113-8456, Tokyo (Japan)

    2003-02-01

    We have implemented a new diffusion-weighted MRI (DWI) sequence based on the single-shot fast spin-echo technique. We hypothesised that this would add information to conventional MRI for diagnosis of lesions of the cervical spinal cord. DWI was performed using a technique in which echo collection after the application of motion-probing gradients was done in the same manner as in the single-shot fast spin-echo technique. We first imaged six healthy volunteers to demonstrate the cervical spinal cord using the sequence. Then we applied the sequence to 12 patients with cervical myelomalacia due to chronic cord compression. The spinal cord was well seen in all subjects without the distortion associated with echo-planar DWI. In the patients, lesions appeared as areas of low- or isointense signal on DWI. Calculated apparent diffusion coefficients of the lesions (3.30{+-}0.38 x 10{sup -3} mm{sup 2}/s) were significantly higher than those of normal volunteers (2.26{+-}0.08 x 10{sup -3} mm{sup 2}/s). Increased diffusion in areas of cervical myelomalacia, suggesting irreversible damage, can be detected using this technique. (orig.)

  8. LHC Report: spring cleaning over, bunches of luminosity

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    Scrubbing was completed on Wednesday 13 April. The run had seen over 1000 bunches per beam successfully circulating at 450 GeV. Measurements showed that electron cloud activity in the cold regions had been suppressed. A decrease of vacuum activity in the warm regions demonstrated that the cleaning had also achieved the required results there. As discussed in the last Bulletin, the scrubbing was performed with high intensity bunches with 50 nanosecond spacing. Given the potential luminosity performance with this spacing (more bunches, higher bunch intensity from the injectors) and in the light of the results of the scrubbing run, the decision was taken to continue the 2011 physics run with this bunch spacing.   A few issues with 50 nanosecond spacing had to be resolved when standard operations for luminosity production resumed. Once things had been tidied up, stable beams were provided for the experiments, firstly with 228 bunches per beam and then with 336 bunches per beam. The 336 bunch fill that w...

  9. Measurement of subpicosecond bunch lengths using coherent Smith-Purcell radiation

    Directory of Open Access Journals (Sweden)

    S. E. Korbly

    2006-02-01

    Full Text Available We report the use of coherent Smith-Purcell radiation to measure the bunch length of femtosecond-scale, 15 MeV electron bunches produced by a 17 GHz rf accelerator. The Smith-Purcell radiation was produced by passing a train of electron bunches above a metal grating. The radiation was verified as Smith-Purcell radiation by measuring the resonance condition, dependence on beam current, and dependence on beam height above the grating. Measurements of the intensity of the radiation vs emission angle were analyzed to obtain the bunch length. The accelerator was operated in two different modes, producing bunches that were determined to have bunch lengths of 600 and 1000±200  fs. These nondestructive bunch length measurements were found to agree well with an independent, but destructive, measurement using a microwave deflecting cavity.

  10. A single-shot T2mapping protocol based on echo-split gradient-spin-echo acquisition and parametric multiplexed sensitivity encoding based on projection onto convex sets reconstruction.

    Science.gov (United States)

    Chu, Mei-Lan; Chang, Hing-Chiu; Oshio, Koichi; Chen, Nan-Kuei

    2018-01-01

    To develop a high-speed T 2 mapping protocol that is capable of accurately measuring T 2 relaxation time constants from a single-shot acquisition. A new echo-split single-shot gradient-spin-echo (GRASE) pulse sequence is developed to acquire multicontrast data while suppressing signals from most nonprimary echo pathways in Carr-Purcell-Meiboom-Gill (CPMG) echoes. Residual nonprimary pathway signals are taken into consideration when performing T 2 mapping using a parametric multiplexed sensitivity encoding based on projection onto convex sets (parametric-POCSMUSE) reconstruction method that incorporates extended phase graph modeling of GRASE signals. The single-shot echo-split GRASE-based T 2 mapping procedure was evaluated in human studies at 3 Tesla. The acquired data were compared with reference data obtained with a more time-consuming interleaved spin-echo echo planar imaging protocol. T 2 maps derived from conventional single-shot GRASE scans, in which nonprimary echo pathways were not appropriately addressed, were also evaluated. Using the developed single-shot T 2 mapping protocol, quantitatively accurate T 2 maps can be obtained with a short scan time (parametric-POCSMUSE reconstruction. Magn Reson Med 79:383-393, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Resistive wall wakefields of short bunches at cryogenic temperatures

    Directory of Open Access Journals (Sweden)

    G. Stupakov

    2015-03-01

    Full Text Available We present calculations of the longitudinal wakefields at cryogenic temperatures for extremely short bunches, characteristic for modern x-ray free electron lasers. The calculations are based on the equations for the surface impedance in the regime of the anomalous skin effect in metals. This paper extends and complements an earlier analysis of B. Podobedov, Phys. Rev. ST Accel. Beams 12, 044401 (2009. into the region of very high frequencies associated with bunch lengths in the micron range. We study in detail the case of a rectangular bunch distribution for parameters of interest of LCLS-II with a superconducting undulator.

  12. Studies on the S-band bunching system with the Hybrid Bunching-accelerating Structure

    Science.gov (United States)

    Pei, Shi-Lun; Gao, Bin

    2018-04-01

    Generally, a standard bunching system is composed of a standing-wave (SW) pre-buncher (PB), a traveling-wave (TW) buncher (B) and a standard accelerating structure. In the industrial area, the bunching system is usually simplified by eliminating the PB and integrating the B and the standard accelerating structure together to form a β-varied accelerating structure. The beam capturing efficiency for this kind of simplified system is often worse than that for the standard one. The hybrid buncher (HB) has been proved to be a successful attempt to reduce the cost but preserve the beam quality as much as possible. Here we propose to exclusively simplify the standard bunching system by integrating the PB, the B and the standard accelerating structure together to form a Hybrid Bunching-accelerating Structure (HBaS). Compared to the standard bunching system, the one based on the HBaS is more compact, and the cost is lowered to the largest extent. With almost the same beam transportation efficiency (∼70%) from the electron gun to the linac exit, the peak-to-peak (p-to-p) beam energy spread and the 1 σ emittance of the linac with the HBaS are ∼20% and ∼60% bigger than those of the linac based on the split PB/B/standard accelerating structure system. Nonetheless, the proposed HBaS can be widely applied in the industrial linacs to greatly increase the beam capturing efficiency without fairly increasing the construction cost.

  13. Three bunch energy stabilization for the SLC injector

    International Nuclear Information System (INIS)

    Sheppard, J.C.; Almog, I.; Bambade, P.S.; Clendenin, J.E.; Jobe, R.K.; Phinney, N.; Shoaee, H.; Stiening, R.F.; Thompson, K.A.

    1986-09-01

    Slow feedback has been developed to control the energy and energy spread of the beams which are injected into the SLC damping rings. Within a single RF pulse, two bunches of electrons and one bunch of positrons are accelerated to an energy of 1.21 GeV in the injector of the SLC. The two electron bunches are deflected into the north damping ring while the positrons are targeted into the south ring. In order to fit into the acceptance of the rings, the composite energy deviation and energy spread of the beams must be less than 2% full width. Control of the beam energy characteristics is accomplished with a set of computer controlled feedback loops which monitor the parameters of the three bunches and make adjustments to the available RF energy, RF phasing, and RF timing. This paper presents an overview of the feedback algorithms and of the special hardware developments, and reports on the operational status of the processes

  14. CRM in the Regime of Nonresonant Bunching

    CERN Document Server

    Bandurkin, I V; Savilov, A V

    2005-01-01

    New regime of electron-wave coupling in cyclotron resonance maser (CRM) is proposed. In this regime, during the most part of interaction process electrons move in the field of rf wave which is relatively far from cyclotron resonance. It is shown, that if resonance mismatch is chosen properly, an effective bunching takes place, an amplitude of forming rf current weakly depending on the velocity spread. Simulations show that, whereas the efficiency of traditional regimes quickly decreases with increasing velocity spread, efficiency of the proposed scheme practically does not change and for relative value of spread in transverse velocities of 40% is twice as large as corresponding efficiency of the conventional regimes. The regime seems to be also prospective for realization of CRM with frequency multiplication. In such a scheme, resonance mismatch for low-frequency wave in bunching section should be such that high-frequency wave be in resonance with the beam. Thus, the device operates like the single-frequency ...

  15. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2014-01-01

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants Km and kcat. The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants Km and kcat can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin β-D-galactopyranoside) and found Km and kcat to be 333±130 =M and 64±8 s−1 respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions. PMID:22880882

  16. Observation of single artificial atom optical bi-stability and its application to single-shot readout in circuit quantum electrodynamics

    Science.gov (United States)

    Sun, Luyan; Ginossar, Eran; Guy, Mikhael; Reed, Matthew; Paik, Hanhee; Bishop, Lev S.; Sears, Adam; Petrenko, Andrei; Brecht, Teresa; Frunzio, Luigi; Girvin, Steven; Schoelkopf, Robert

    2012-02-01

    The high power transient behavior of superconducting qubit-cavity systems has recently been used to perform high fidelity readout of transmon qubits [1]. We show that in the steady state, the system exhibits a bi-stable behavior that can be observed on the single-shot level, with the cavity state switching stochastically between dim and bright states. The switching times are shown to be long compared to the cavity and qubit lifetimes. Some features of the bi-stability can be explained by mean field theory, while its switching dynamics is studied with large scale simulations. Understanding these dynamics will be crucial for studying the transient response, an essential aspect of the qubit readout. We will discuss progress on optimizing readout by shaping the measurement pulse. [4pt] [1] M. D. Reed, L. DiCarlo, B. R. Johnson, L. Sun, D. I. Schuster, L. Frunzio, and R. J. Schoelkopf, Phys. Rev. Lett. 105, 173601 (2010)

  17. Clinical single-shot diffusion-weighted MRI of the human brain on a short-bore medium-field imager

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Remonda, L.; Schneider, J.; Goenner, F.; Schroth, G.; Heid, O.

    1999-01-01

    Diffusion-weighted MRI (DWI) is becoming important for assessment of acute stroke. Until recently single-shot DWI required expensive technology such as echo-planar imaging (EPI) available only at some research sites. A new medium-field (1.0 T) short-bore MR imager has been developed with which DWI data sets can be acquired. We prospectively studied 169 patients on this 1.0 T commercial system. After conventional imaging, DWI was performed with a single-shot multi-slice sequence with b values 0 an 900 s/mm 2 , and with the gradients switched in three directions. The apparent diffusion coefficients were calculated with online calculation software. There were 50 patients with totally normal MRI, and 17 had strokes, these strokes were detected as areas of high signal on the images at a maximal b value. There was a drop in the ADC in ischaemic regions: in subacute infarcts, the values were between 0.41 and 0.531 x 10 - 3 mm 2 /s. In old infarcts the ADC was 1.15 x 10 - 3 mm 2 /s. Cerebrospinal fluid (CSF) gave low signal whereas areas in the brain had more intermediate intensities (CSF: 3.00; deep white matter: 0.75, cortical grey matter: 0.80, basal ganglia (thalamus): 0.70 and cerebellar white matter: 0.65 x 10 - 3 mm 2 /s). Anisotropy was detected as areas of restricted diffusion along the tracts. These preliminary data show that DWI can be aquired successfully on a medium-field short-bore system. This should allow the technique to be implemented at more sites, therefore facilitating the diagnosis of acute stroke and rendering early intervention feasible. (orig.)

  18. Quantitative analysis of the breath-holding half-Fourier acquisition single-shot turbo spin-echo technique in abdominal MRI

    Science.gov (United States)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan

    2013-01-01

    A consecutive series of 50 patients (28 males and 22 females) who underwent hepatic magnetic resonance imaging (MRI) from August to December 2011 were enrolled in this study. The appropriate parameters for abdominal MRI scans were determined by comparing the images (TE = 90 and 128 msec) produced using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) technique at different signal acquisition times. The patients consisted of 15 normal patients, 25 patients with a hepatoma and 10 patients with a hemangioma. The TE in a single patient was set to either 90 msec or 128 msec. This was followed by measurements using the four normal rendering methods of the biliary tract system and the background signal intensity using the maximal signal intensity techniques in the liver, spleen, pancreas, gallbladder, fat, muscles and hemangioma. The signal-to-noise and the contrast-to-noise ratios were obtained. The image quality was assessed subjectively, and the results were compared. The signal-to-noise and the contrast-to-noise ratios were significantly higher at TE = 128 msec than at TE = 90 when diseases of the liver, spleen, pancreas, gallbladder, and fat and muscles, hepatocellular carcinomas and hemangiomas, and rendering the hepatobiliary tract system based on the maximum signal intensity technique were involved (p breath-hold half-Fourier acquisition single-shot turbo spin-echo (HASTE) was found to be effective in illustrating the abdominal organs for TE = 128 msec. Overall, the image quality at TE = 128 msec was better than that at TE = 90 msec due to the improved signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Overall, the HASTE technique for abdominal MRI based on a high-magnetic field (3.0 T) at a TE of 128 msec can provide useful data.

  19. CSR Interaction for a 2D Energy-Chirped Bunch on a General Orbit

    International Nuclear Information System (INIS)

    Li, Rui

    2009-01-01

    When an electron bunch with initial linear energy chirp traverses a bunch compression chicane, the bunch interacts with itself via coherent synchrotron radiation (CSR) and space charge force. The effective longitudinal CSR force for such kind of 2D bunch on a circular orbit has been analyzed earlier (1). In this paper, we present the analytical results of the effective longitudinal CSR force for a 2D energy-chirped bunch going through a general orbit, which includes the entrance and exit of a circular orbit. In particular, we will show the behavior of the force in the last bend of a chicane when the bunch is under extreme compression. This is the condition when bifurcation of bunch phase space occurs in many CSR measurements. (1) R. Li, Phys. Rev. ST Accel. Beams 11, 024401 (2008)

  20. Downsampled bunch-by-bunch feedback for PEP II

    International Nuclear Information System (INIS)

    Hindi, H.A.; Briggs, D.; Fox, J.; Hosseini, W.; Hutton, A.

    1992-09-01

    The PEP II B Factory requires a feedback system to damp out longitudinal synchrotron oscillations. A time-domain bunch-by-bunch feedback system has been proposed in which each bunch is treated as an oscillator being driven by disturbances from the other bunches. The phase is detected, filtered, and the feedback correction signal is applied by the kicker. Since we are damping energy oscillations using measurements of phase, the required feedback signal must be proportional to the amplitude of the phase oscillations but phase shifted by 90 degrees. This signal must be calculated for each of the 1658 bunches, in parallel. In the original proposal, it was estimated that a farm of approximately 480 digital signal processors (DIPS) would be required to implement the feedback system. However, using the technique of downsampling, this number can be reduced to about 50 DIPS. In what follows, we will briefly explain the basic idea of downsampling and its implementation

  1. Downsampled bunch-by-bunch feedback for PEP II

    International Nuclear Information System (INIS)

    Hindi, H.A.; Briggs, D.; Fox, J.; Hosseini, W.; Hutton, A.

    1992-01-01

    The PEP 11 B Factory requires a feedback system to damp out longitudinal synchrotron oscillations. A time-domain bunch-by-bunch feedback system has been proposed in which each bunch is treated as an oscillator being driven by disturbances from the other bunches. The phase is detected, filtered, and the feedback correction signal is applied by the kicker. Since we are damping energy oscillations using measurements of phase, the required feedback signal must be proportional to the amplitude of the phase oscillations but phase shifted by 90 degrees. This signal must be calculated for each of the 1658 bunches, in parallel. In the original proposal, it was estimated that a farm of approximately 480 digital signal processors (DSPS) would be required to implement the feedback system. However, using the technique of downsampling, this number can be reduced to about 50 DSPS. In what follows, we will briefly explain the basic idea of downsampling and its implementation

  2. Resonance fluorescence and electron spin in semiconductor quantum dots

    International Nuclear Information System (INIS)

    Zhao, Yong

    2009-01-01

    The work presented in this dissertation contains the first observation of spin-resolved resonance fluorescence from a single quantum dot and its application of direct measurement of electron spin dynamics. The Mollow triplet and the Mollow quintuplet, which are the hallmarks of resonance fluorescence, are presented as the non-spin-resolved and spin-resolved resonance fluorescence spectrum, respectively. The negligible laser background contribution, the near pure radiative broadened spectrum and the anti-bunching photon statistics imply the sideband photons are background-free and near transform-limited single photons. This demonstration is a promising step towards the heralded single photon generation and electron spin readout. Instead of resolving spectrum, an alternative spin-readout scheme by counting resonance fluorescence photons under moderate laser power is demonstrated. The measurements of n-shot time-resolved resonance fluorescence readout are carried out to reveal electron spin dynamics of the measurement induced back action and the spin relaxation. Hyperfine interaction and heavy-light hole mixing are identified as the relevant mechanisms for the back action and phonon-assistant spin-orbit interaction dominates the spin relaxation. After a detailed discussion on charge-spin configurations in coupled quantum dots system, the single-shot readout on electron spin are proposed. (orig.)

  3. Resonance fluorescence and electron spin in semiconductor quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yong

    2009-11-18

    The work presented in this dissertation contains the first observation of spin-resolved resonance fluorescence from a single quantum dot and its application of direct measurement of electron spin dynamics. The Mollow triplet and the Mollow quintuplet, which are the hallmarks of resonance fluorescence, are presented as the non-spin-resolved and spin-resolved resonance fluorescence spectrum, respectively. The negligible laser background contribution, the near pure radiative broadened spectrum and the anti-bunching photon statistics imply the sideband photons are background-free and near transform-limited single photons. This demonstration is a promising step towards the heralded single photon generation and electron spin readout. Instead of resolving spectrum, an alternative spin-readout scheme by counting resonance fluorescence photons under moderate laser power is demonstrated. The measurements of n-shot time-resolved resonance fluorescence readout are carried out to reveal electron spin dynamics of the measurement induced back action and the spin relaxation. Hyperfine interaction and heavy-light hole mixing are identified as the relevant mechanisms for the back action and phonon-assistant spin-orbit interaction dominates the spin relaxation. After a detailed discussion on charge-spin configurations in coupled quantum dots system, the single-shot readout on electron spin are proposed. (orig.)

  4. Single bunch instabilities in an SSC

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1984-01-01

    In this note coherent instability thresholds are estimated for the SSC and discuss some of the subsequent design restrictions. The various instabilities are set out in a block diagram with the essential features of each. The assumption is made that long wavelength coupled bunch effects can be cured effectively by a feedback system (both longitudinal and transverse) and that the impedance of the feedback system is such as to cancel that of the environment (at low frequency). Alternatively, the long wake field is assumed to be exactly canceled, on the average, by a feedback wake field. This leaves only single bunch effects. Thresholds for fast-blowup are discussed both in the longitudinal and transverse and the transverse mode coupling instability more familiar in electron/positron storage rings is covered. The impedances considered are a broadband impedance and the resistive wall impedance

  5. Fast cooling of bunches in compton storage rings*

    CERN Document Server

    Bulyak, E; Zimmermann, F

    2011-01-01

    We propose an enhancement of laser radiative cooling by utilizing laser pulses of small spatial and temporal dimensions, which interact only with a fraction of an electron bunch circulating in a storage ring. We studied the dynamics of such electron bunch when laser photons scatter off the electrons at a collision point placed in a section with nonzero dispersion. In this case of ‘asymmetric cooling’, the stationary energy spread is much smaller than under conditions of regular scattering where the laser spot size is larger than the electron beam; and the synchrotron oscillations are damped faster. Coherent oscillations of large amplitude may be damped within one synchrotron period, so that this method can support the rapid successive injection of many bunches in longitudinal phase space for stacking purposes. Results of extensive simulations are presented for the performance optimization of Compton gamma-ray sources and damping rings.

  6. Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

    NARCIS (Netherlands)

    Coenegrachts, Kenneth; Matos, Celso; ter Beek, Léon; Metens, Thierry; Haspeslagh, Marc; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2009-01-01

    Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5 min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). Materials and

  7. X-ray pulse preserving single-shot optical cross-correlation method for improved experimental temporal resolution

    International Nuclear Information System (INIS)

    Beye, M.; Krupin, O.; Hays, G.; Jong, S. de; Lee, S.; Coffee, R.; Holmes, M. R.; Fry, A. R.; White, W. E.; Bostedt, C.; Schlotter, W. F.; Reid, A. H.; Rupp, D.; Lee, W.-S.; Scherz, A. O.; Chuang, Y.-D.; Cryan, J. P.; Glownia, J. M.; Foehlisch, A.; Durr, H. A.

    2012-01-01

    We measured the relative arrival time between an optical pulse and a soft x-ray pulse from a free-electron laser. This femtosecond cross-correlation measurement was achieved by observing the change in optical reflectivity induced through the absorption of a fraction of the x-ray pulse. The main x-ray pulse energy remained available for an independent pump-probe experiment where the sample may be opaque to soft x-rays. The method was employed to correct the two-pulse delay data from a canonical pump-probe experiment and demonstrate 130 ± 20 fs (FWHM) temporal resolution. We further analyze possible timing jitter sources and point to future improvements.

  8. Digital bunch-by-bunch transverse feedback system at SSRF

    Science.gov (United States)

    Yuan, RenXian; Leng, YongBin; Yu, LuYang; Han, LiFeng; Ye, KaiRong

    2011-12-01

    In order to suppress multi-bunch couple instabilities caused by transverse impedance, a bunch-by-bunch transverse feedback system based on a FPGA digital processor is commissioned at SSRF storage ring. The RF front end has two COD pre-rejected attenuators for increasing the system arrangement and signal noise ratio, and the 3*RF Local signal comes from the BPM's sum signal using a FIR filter for avoiding the effect of longitudinal oscillation. The digital processor receives the coupled horizontal and vertical oscillation signals in the base band and transforms the coupled signals to the horizontal and vertical feedback signals with two series double-zeroes FIR filters. A matlab GUI is applied for producing the FIR coefficients when the tune is shifted. The horizontal and vertical Kickers have a special design for increasing the shunt impedance. Then the multi-bunch instabilities are suppressed respectively and the minimum damping time is about 0.4 ms.

  9. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    Science.gov (United States)

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. [In-phase and out-of-phase single-shot magnetization-prepared gradient recalled echo: description and optimization of technique at 1.5 T].

    Science.gov (United States)

    Ramalho, M; Herédia, V; de Campos, R O P; de Toni, M; Dale, B M; Semelka, R C

    2014-01-01

    To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements. Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests. There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients. Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001). MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence. Single shot IP/OP MP-GRE is feasible and allows motion resistant

  11. Single shot spinal anesthesia with very low hyperbaric bupivacaine dose (3.75 mg) for hip fracture repair surgery in the elderly. A randomized, double blinded study.

    Science.gov (United States)

    Errando, C L; Peiró, C M; Gimeno, A; Soriano, J L

    2014-11-01

    Single shot spinal anesthesia is used worldwide for hip fracture repair surgery in the elderly. Arterial hypotension is a frequent adverse effect. We hypothesized that lowering local anesthetics dose could decrease the incidence of arterial hypotension, while maintaining quality of surgical anesthesia. In a randomized double blinded study, 66 patients over the age of 65 years, with hip fracture needing surgical repair, were assigned to B0.5 group 7.5mg hyperbaric bupivacaine 5mg/ml (control group), and B0.25 group 3.75mg hyperbaric bupivacaine 2.5mg/ml (study group). Sensory and motor block level, and hemodynamic parameters including blood presure, heart rate and vasopressor dose administration were registered, along with rescue anesthesia needs, the feasibility of surgery, its duration, and regression time of sensory anesthesia to T12. After exclusions, 61 patients were included in the final analysis. Arterial hypotension incidence was lower in the B0.25 group (at the 5, 10, and 15min determinations), and a lower amount of vasopressor drugs was needed (mean accumulated ephedrine dose 1.6mg vs. 8.7mg in the B0.5 group, p<0.002). Sensory block regression time to T12 was shorter in the B0.25 group, mean 78.6±23.6 (95% CI 51.7-110.2)min vs. 125.5±37.9 (95% CI 101.7-169.4)min in the B0.5 group, p=0.033. All but one patient in the B0.25 group were operated on under the anesthetic procedure first intended. No rescue anesthesia was needed. Lowering bupivacaine dose for single shot spinal anesthesia for hip fracture repair surgery in elderly patients was effective in decreasing the occurrence of arterial hypotension and vasopressor use, while intraoperative quality remained. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Exploring ultrashort high-energy electron-induced damage in human carcinoma cells

    International Nuclear Information System (INIS)

    Rigaud, O.; Fortunel, N.O.; Vaigot, P.; Cadio, E.; Martin, M.T.; Lundh, O.; Faure, J.; Rechatin, C.; Malka, V.; Gauduel, Y.A.

    2010-01-01

    In conventional cancer therapy or fundamental radiobiology research, the accumulated knowledge on the complex responses of healthy or diseased cells to ionizing radiation is generally obtained with low-dose rates. Under these radiation conditions, the time spent for energy deposition is very long compared with the dynamics of early molecular and cellular responses. The use of ultrashort pulsed radiation would offer new perspectives for exploring the 'black box' aspects of long irradiation profiles and favouring the selective control of early damage in living targets. Several attempts were previously performed using nanosecond or picosecond pulsed irradiations on various mammalian cells and radiosensitive mutants at high dose rate. The effects of single or multi-pulsed radiations on cell populations were generally analyzed in the framework of dose survival curves or characterized by 2D imaging of γ-H2AX foci and no increase in cytotoxicity was shown compared with a delivery at a conventional dose rate. Moreover, when multi-shot irradiations were performed, the overall time needed to obtain an integrated dose of several Grays again overlapped with the multi-scale dynamics of bio-molecular damage-repair sequences and cell signalling steps. Ideally, a single-shot irradiation delivering a well-defined energy profile, via a very short temporal window, would permit the approach of a real-time investigation of early radiation induced molecular damage within the confined spaces of cell compartments. Owing to the potential applications of intense ultrashort laser for radiation therapy, the model of the A431 carcinoma cell line was chosen. An ultrafast single-shot irradiation strategy was carried out with these radio-resistant human skin carcinoma cells, using the capacity of an innovating laser-plasma accelerator to generate quasi mono-energetic femtosecond electron bunches in the MeV domain and to deliver a very high dose rate of 10 13 Gy s -1 per pulse. The alkaline comet

  13. Space-charge dynamics in ultra-cold ion bunches

    Science.gov (United States)

    Scholten, Robert; Murphy, Dene; Speirs, Rory; Thompson, Daniel; Sparkes, Benjamin; McCulloch, Andrew

    2014-05-01

    Cold ion sources based on photoionisation of laser cooled atoms provide a unique system for investigating Coulomb interactions within complex charged particle bunches. Space-charge driven expansion in charged particle beams is of critical importance for applications including electron and ion microscopy, mass spectrometry, synchrotrons and x-ray free electron lasers, and in electron diffraction where space-charge effects constrain the capacity to obtain diffraction information. Self-field effects are often difficult to observe because of thermal diffusion with traditional sources. Cold atom sources produce ions with temperatures of a few mK, such that subtle space-charge effects are apparent. We illustrate the capabilities through detailed investigation of a complex ion bunch shape, showing collective behaviour including high density caustics and shockwave structures arising from long-range interactions between small charge bunches.

  14. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  15. High intensity bunch length instabilities in the SLC damping rings

    International Nuclear Information System (INIS)

    Krejcik, P.; Bane, K.; Corredoura, P.; Decker, F.J.; Judkins, J.; Limberg, T.; Minty, M.; Siemann, R.H.

    1993-01-01

    The SLC damping rings function to provide low emittance, short bunches for injection into the linac. As the beam intensity in the rings was raised, as part of the SLC luminosity improvement program, the authors observed a threshold above which beam jitter would occur in the linac. Frequent machine trips, caused by beam loss on some bunches, were associated with the jitter. These erratic open-quotes flierclose quotes pulses were traced to extraction phase errors from the damping rings. This paper covers the diagnosis of this condition and the observations of the transient bunch length instability phenomena. The evidence of this turbulent (microwave) bunch length instability is seen in both time domain and in frequency domain measurements. The instability has been dubbed the open-quotes sawtoothclose quotes because of the characteristic time dependent nature of the phase and bunch length signals. It is present in both the SLC electron and positon damping rings at about the same threshold of 3x10 10 particles per bunch

  16. Characterestics of pico-second single bunch at the S-band linear accelerator

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru; Kozawa, Takahiro; Kobayashi, Toshiaki; Ueda, Toru; Miya, Kenzo

    1994-01-01

    Measurement of the bunch structure of a pico-second single bunch was performed using a femto-second streak camera at the S-band linear accelerator of the University of Tokyo. The aim of this research is to investigate the feasibility of the generation of a femto-second single bunch at the S-band linac. The details of the bunch structure and energy spectrum of an original single bunch were precisely investigated in several operation modes where the RF phases in accelerating tubes and a prebuncher were varied. The femto-second streak camera was utilized to measure the bunch structure by one shot via Cherenkov radiation emitted by the electrons in the bunch. Next, an experiment for magnetic pulse compression of the original single bunch was carried out. Pulse shapes of the compressed bunchs for different energy modulation were also obtained by measuring Cherenkov radiation by one shot using the femto-second streak camera. Prior to the experiment, numerical tracking analysis to determine operating parameters for the magnetic pulse compression was also done. Measured pulse widths were compared with calculated ones. Finally, a 2 ps (full width at half maximum; FWHM) single bunch with an electric charge of 0.3 nC could be generated by the magnetic pulse compression. ((orig.))

  17. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  18. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer.

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2012-09-04

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants K(m) and k(cat). The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants K(m) and k(cat) can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin-β-D-galactopyranoside) and found K(m) and k(cat) to be 333 ± 130 μM and 64 ± 8 s(-1), respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions.

  19. The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma

    International Nuclear Information System (INIS)

    De Foer, Bert; Bernaerts, Anja; Maes, Joachim; Deckers, Filip; Pouillon, Marc; Vercruysse, Jean-Philippe; Somers, Thomas; Offeciers, Erwin; Michiels, Johan; Casselman, Jan W.

    2007-01-01

    Single-shot (SS) turbo spin-echo (TSE) diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non echo-planar imaging (EPI) technique recently reported for the evaluation of middle ear cholesteatoma. We prospectively evaluated a SS TSE DW sequence in detecting congenital or acquired middle ear cholesteatoma and evaluated the size of middle ear cholesteatoma detectable with this sequence. The aim of this study was not to differentiate between inflammatory tissue and cholesteatoma using SS TSE DW imaging. A group of 21 patients strongly suspected clinically and/or otoscopically of having a middle ear cholesteatoma without any history of prior surgery were evaluated with late post-gadolinium MRI including this SS TSE DW sequence. A total of 21 middle ear cholesteatomas (5 congenital and 16 acquired) were found at surgery with a size varying between 2 and 19 mm. Hyperintense signal on SS TSE DW imaging compatible with cholesteatoma was found in 19 patients. One patient showed no hyperintensity due to autoevacuation of the cholesteatoma sac into the external auditory canal. Another patient showed no hyperintensity because of motion artifacts. This study shows the high sensitivity of this SS TSE DW sequence in detecting small middle ear cholesteatomas, with a size limit as small as 2 mm. (orig.)

  20. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  1. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  2. Coasting beam theory applied to bunches

    International Nuclear Information System (INIS)

    Hereward, H.

    1975-01-01

    It is plausible to apply coasting beam criteria to bunches if one has short wavelength disturbances of the bunch and short memory wake fields, where short means short compared with a bunch length, for then one can argue that a piece of the bunch near the middle does not even know that the bunch has ends. Some other conditions probably required to validate this approach are discussed. The local Keil-Schnell criterion is derived from the local dispersion integral

  3. Virtual photon impulse of bunch, beampipe response, coherent RF Beamstrahlung; and BEPC bunch length, BES jam, virtual acceleration

    International Nuclear Information System (INIS)

    Jing Shen

    1993-01-01

    A brief EEE view of signal QED is presented. The research has been concentrated on the virtual photon modes of ultra relativistic shock wave in a bunch-beampipe system, and real photon modes of Coherent RF Beamstrahlung CRFB. Physically, the virtual photons emitted by a bunch were treated as a travelling pseudo wave packet in a flight coaxial cavity constructed by bunch-wakefield core and beampipe. Mathematically, it is a boundary solution of shock wave excited by ultra relativistic impulse of bunch. The new modes of solution: VTA, VTEM, VTM, VLE are virtual photon packets and RTE, RTM, RTEM are real photon modes of CRFB. By these results the author measured and corrected BEPC bunch length from signals of : (1) TOF reference of BES, (2) BPM of BEPC, (3) Colliding CRFB of BEPC - BES coupling signal, as well as (4) the ordinary method of Synchrotron Radiation. All results of the measured bunch lengths are in accordance with the design length of BEPC, and were verified by the BES data of vertex reconstruction of hadron events. The author also found that CRFB is the unknown jam source of BES electronics. VLE virtual photons can accelerate particles

  4. Simulation of Transverse Multi-Bunch Instabilities of Proton Beams in LHC

    CERN Document Server

    Koschik, Alexander; Zotter, Bruno

    The CERN Large Hadron Collider (LHC) is designed for highest luminosity and therefore requires operation with a large number of bunches and high intensities. Its performance could be limited by the electromagnetic interaction between the charged particle beam and its surroundings which cause collective instabilities. This thesis describes methods of simulating and analyzing multi-bunch instabilities in circular accelerators and storage rings. The simulation models as well as analyzing tools presented here, also facilitate the interpretation of measurements in multi-bunch machines. The 3-dimensional, multi-bunch tracking program MultiTRISIM was developed, based on its single-bunch predecessor TRISIM3D. It allows the exploration of longrange effects in round or flat vacuum chambers for equidistant or uneven filling schemes. Previous computer simulations of collective effects concentrated mainly on instabilities of single or few bunches in electron storage rings. There, the strong radiation damping reduces the r...

  5. Caustic-based approach to understanding bunching dynamics and current spike formation in particle bunches

    Directory of Open Access Journals (Sweden)

    T. K. Charles

    2016-10-01

    Full Text Available Current modulations, current spikes, and current horns, are observed in a range of accelerator physics applications including strong bunch compression in Free Electron Lasers and linear colliders, trains of microbunching for terahertz radiation, microbunching instability and many others. This paper considers the fundamental mechanism that drives intense current modulations in dispersive regions, beyond the common explanation of nonlinear and higher-order effects. Under certain conditions, neighboring electron trajectories merge to form caustics, and often result in characteristic current spikes. Caustic lines and surfaces are regions of maximum electron density, and are witnessed in accelerator physics as folds in phase space of accelerated bunches. We identify the caustic phenomenon resulting in cusplike current profiles and derive an expression which describes the conditions needed for particle-bunch caustic formation in dispersive regions. The caustic expression not only reveals the conditions necessary for caustics to form but also where in longitudinal space the caustics will form. Particle-tracking simulations are used to verify these findings. We discuss the broader implications of this work including how to utilize the caustic expression for manipulation of the longitudinal phase space to achieve a desired current profile shape.

  6. Bunch-by-bunch intensity monitor for Fermilab main ring

    International Nuclear Information System (INIS)

    Pasquinelli, R.J.

    1983-01-01

    A bunch-by-bunch intensity monitor has been developed for the Fermilab Main Ring with future intended use in the Energy Doubler/Saver. The input signal is a beam doublet from a quarter wave stripline pickup that varies from 2 to 8 nanoseconds FWHM. The faithful integration of this pulse will produce an intensity signal proportional to the number of protons per bunch. The technique used is a fast integrate, hold, and damp. The intensity output is then made available for digitizing in the Snapshot Digitizer System. Beam losses at various points of the accelerating cycle may then be monitored on a bunch-by-bunch basis. The intensity monitor requires, in addition to the beam doublet, the input of a synchronized VCO. It is important that the group delay of both the VCO and beam input lines be identical so as not to change the phase relationship between the two as the RF is frequency modulated during acceleration. The doublet input dynamic range adjustment is a switched bank of coaxial attenuators. Their selection is based on predicted beam intensity for each accelerator cycle. A block diagram of the intensity monitor is provided

  7. Optimization of a train of bunches for plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Martorelli, Roberto

    2016-05-10

    Particle accelerators are a fundamental instrument for the understanding of fundamental mechanism in nature. The need of always higher energies for the particle beams requires a huge increase of the sizes of the accelerators using the actual technology. Moreover the highest energies are achieved nowadays by circular colliders, not perfectly suitable for acceleration of electrons and positrons due to the radiation losses. In order to overcome this problem a new branch of physics studying alternative technique for particle acceleration has been developed. Among the various alternatives a promising one is the plasma wakefield acceleration (PWFA), in which a driver bunch interacts with a cold background plasma, exciting a plasma wave. The electric field of the plasma wave is then used for the acceleration of a second bunch. Such a mechanism allows to reach fields strength far beyond currently available, limited by the dielectric strength of the material. Among the different driver configurations, a promising one is the use of a modulated beam, namely a train of bunches, that provides a coherent interference among the electric fields generated by the single bunches. Such mechanism is subjected to a renewed interest in view of the forthcoming AWAKE experiment at CERN in which the long proton beam produced at the SPS facility is used as a driver. This possibility is achieved thanks to the onset of the self-modulation instability that modulates the long beam in a train of approximately 100 bunches. In order to accelerate the witness bunch to high energies is necessary on the other hand an efficient exchange of energy from the driver to the accelerated bunch, as well as a long duration of the driver so that can propagates for kilometers. This thesis deals with this two last aspects. The aim of this work is to provide an optimization for the modulated driver in order to improve specific features of the PWFA. This work shows the possibility to achieve an improved efficiency

  8. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  9. Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique: A methodological study of the aging brain

    International Nuclear Information System (INIS)

    Chen, Z.G.; Hindmarsh, T.; Li, T.Q.

    2001-01-01

    Purpose: To quantify age-related changes of the average diffusion coefficient value in normal adult brain using orientation-independent diffusion tensor trace mapping and to address the methodological influences on diffusion quantification. Material and Methods: Fifty-four normal subjects (aged 20-79 years) were studied on a 1.5-T whole-body MR medical unit using a diffusion-weighted single-shot echo-planar imaging technique. Orientation-independent diffusion tensor trace maps were constructed for each subject using diffusion-weighted MR measurements in four different directions using a tetrahedral gradient combination pattern. The global average (including cerebral spinal fluid) and the tissue average of diffusion coefficients in adult brains were determined by analyzing the diffusion coefficient distribution histogram for the entire brain. Methodological influences on the measured diffusion coefficient were also investigated by comparing the results obtained using different experimental settings. Results: Both global and tissue averages of the diffusion coefficient are significantly correlated with age (p<0.03). The global average of the diffusion coefficient increases 3% per decade after the age of 40, whereas the increase in the tissue average of diffusion coefficient is about 1% per decade. Experimental settings for self-diffusion measurements, such as data acquisition methods and number of b-values, can slightly influence the statistical distribution histogram of the diffusion tensor trace and its average value. Conclusion: Increased average diffusion coefficient in adult brains with aging are consistent with findings regarding structural changes in the brain that have been associated with aging. The study also demonstrates that it is desirable to use the same experimental parameters for diffusion coefficient quantification when comparing between different subjects and groups of interest

  10. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Science.gov (United States)

    Levato, T.; Labate, L.; Pathak, N. C.; Cecchetti, C.; Koester, P.; Di Fabrizio, E.; Delogu, P.; Giulietti, A.; Giulietti, D.; Gizzi, L. A.

    2010-11-01

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime [1] (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators [1,2] (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project [3] (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described [4] (Levato et al., 2008).

  11. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Levato, T., E-mail: tadzio.levato@lnf.infn.i [FLAME, Laboratori Nazionali di Frascati (LNF), Via E. Fermi 40, 00044 Frascati (Italy); Labate, L.; Pathak, N.C.; Cecchetti, C.; Koester, P. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Di Fabrizio, E. [BIONEM, Campus Magna Graecia University of Catanzaro (UMG) (Italy); Delogu, P. [University of Pisa, Department of Physics (Italy); Giulietti, A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Giulietti, D. [University of Pisa, Department of Physics (Italy); Gizzi, L.A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy)

    2010-11-11

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described (Levato et al., 2008).

  12. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences.

    Science.gov (United States)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M; Saranathan, Manojkumar; Litwiller, Daniel V; Vasanawala, Shreyas S

    2015-06-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity.

  13. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    International Nuclear Information System (INIS)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S.; Litwiller, Daniel V.

    2015-01-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  14. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet; Moineddin, Rahim; Babyn, Paul S.

    2013-01-01

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  15. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  16. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  17. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  18. Non-chromatographic preparation of a bacterially produced single-shot modular virus-like particle capsomere vaccine for avian influenza.

    Science.gov (United States)

    Wibowo, Nani; Wu, Yang; Fan, Yuanyuan; Meers, Joanne; Lua, Linda H L; Middelberg, Anton P J

    2015-11-04

    Highly pathogenic avian influenza (HPAI) causes significant economic loss, reduced food security and poses an ongoing pandemic threat. Poultry vaccination significantly decreases these problems and recognizes that the health of humans, animals and ecosystems are connected. Low-cost manufacture of poultry vaccine matched quickly to the ever-changing circulating strain is needed for effective vaccination. Here, we re-engineered the process to manufacture bacterially synthesized modular capsomere comprising influenza M2e, previously shown to confer complete protection in challenged mice, for application in poultry. Modular capsomere was prepared using a simplified non-chromatographic salting-out precipitation method and its immunogenicity tested in vivo in poultry. Modular capsomere crudely purified by precipitation (pCapM2e) contained more contaminants than equivalent product purified by chromatography (cCapM2e). Unadjuvanted pCapM2e containing 80 EU of endotoxin per dose was inferior to highly purified and adjuvanted cCapM2e (2 EU per dose). However, addition of adjuvant to pCapM2e resulting in high immunogenicity after only a single dose of vaccination, yet without any local adverse reaction. This finding suggests a strong synergy between adjuvant, antigen and contaminants, and the possible existence of a "Goldilocks" level of contaminants, where high immunogenicity and low reactogenicity can be obtained in a single-shot vaccination. The simplified process offers potential cost and speed advantages to address the needs in influenza poultry vaccination in low-cost veterinary markets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.

    Science.gov (United States)

    Yoshida, Tsukasa; Urikura, Atsushi; Shirata, Kensei; Nakaya, Yoshihiro; Terashima, Shingo; Hosokawa, Yoichiro

    2016-09-01

    This study aimed to evaluate the image quality and apparent diffusion coefficient (ADC) values of single-shot turbo spin echo (TSE) diffusion-weighted (DW) images obtained using a parallel imaging (PI) technique. All measurements were performed on a 3.0-T whole-body MRI system and 32-channel phased-array coil. Signal-to-noise ratio (SNR) and ADC values were measured with a DW imaging (DWI) phantom comprising granulated sugar and agar. The SNRs were calculated using a subtraction method and compared among TSE-DW images at acceleration factors (AFs) of 1-4. Image blur was visually assessed on TSE-DW images of a pin phantom at AFs of 1-4. The ADC values were calculated using DW images with b = 0 and 1000 s mm(-2). The ADC values of TSE-DW images and echo-planar imaging EPI-DW images were compared. The SNRs decreased as AFs increased, despite selecting the shortest echo time. A lower AF caused increased image blur in the phase-encoding direction. The ADC values of TSE-DWI tended to be lower than those of EPI-DWI, and AFs of 3 and 4 yielded variable ADC values on TSE-DW images. TSE-DWI with an AF of 3 or 4 yielded reduced SNRs; in addition, the image noise and artefacts associated with PI technique may have affected ADC measurements, despite improving image blur in the phase-encoding direction. Optimizing the imaging parameters of TSE-DWI is useful for providing good image quality and accurate ADC measurements.

  20. Single-bunch kicker pulser

    International Nuclear Information System (INIS)

    Frey, W.W.

    1983-01-01

    The single-bunch kicker magnet is powered by a capacitor discharge pulser. The ferrite-core magnet is used to kick out one of twelve proton bunches circulating in the AGS (Alternating Gradient Synchrotron) into the experimental area. The magnet current pulse has a half-sinusoid shape, with a peak current of 2800 A. The pulse current rises and falls to zero, with minimum undershoot, in 410 nsec to minimize effects on adjacent bunches. The magnet inductance is 1.0 μHy. The pulser is mounted on the kicker magnet in the AGS ring, and is exposed to ionizing radiation. The HVDC power supply, controls, monitoring, and auxiliary circuits are housed approximately 300 feet away external to the ring. A two-gap thyratron is used to discharge the energy storage capacitor. Two hydrogen diodes are series connected to function as an inverse diode

  1. Single-bunch kicker pulser

    Energy Technology Data Exchange (ETDEWEB)

    Frey, W.W.

    1983-01-01

    The single-bunch kicker magnet is powered by a capacitor discharge pulser. The ferrite-core magnet is used to kick out one of twelve proton bunches circulating in the AGS (Alternating Gradient Synchrotron) into the experimental area. The magnet current pulse has a half-sinusoid shape, with a peak current of 2800 A. The pulse current rises and falls to zero, with minimum undershoot, in 410 nsec to minimize effects on adjacent bunches. The magnet inductance is 1.0 ..mu..Hy. The pulser is mounted on the kicker magnet in the AGS ring, and is exposed to ionizing radiation. The HVDC power supply, controls, monitoring, and auxiliary circuits are housed approximately 300 feet away external to the ring. A two-gap thyratron is used to discharge the energy storage capacitor. Two hydrogen diodes are series connected to function as an inverse diode.

  2. Emittance growth of bunched beams in bends

    International Nuclear Information System (INIS)

    Carlsten, B.E.; Raubenheimer, T.O.

    1995-01-01

    Talman [Phys. Rev. Lett. 56, 1429 (1986)] has proposed a novel relativistic effect that occurs when a charged particle beam is bent in the magnetic field from an external dipole. The consequence of this effect is that the space-charge forces from the particles do not exhibit the usual inverse-square energy dependence and some part of them are, in fact, independent of energy. This led to speculation that this effect could introduce significant emittance growth for a bending electron beam. Subsequently, it was shown that this effect's influence on the beam's transverse motion is canceled for a dc beam by a potential depression within the beam (to first order in the beam radius divided by the bend radius). In this paper, we extend the analysis to include short bunch lengths (as compared to the beam pipe dimensions) and find that there is no longer the cancellation for forces both transverse to and in the direction of motion. We provide an estimate for the emittance growth as a function of bend angle, beam radius, and current, and for magnetic compression of an electron bunch

  3. A hybrid approach for generating ultra-short bunches for advanced accelerator applications

    Energy Technology Data Exchange (ETDEWEB)

    Stratakis, Diktys [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-01

    Generation of electron beams with high phase-space density, short bunch length and high peak current is an essential requirement for future linear colliders and bright electron beam sources. Unfortunately, such bunches cannot be produced directly from the source since forces from the mutual repulsion of electrons would destroy the brilliance of the beam within a short distance. Here, we detail a beam dynamics study of an innovative two-stage compression scheme that can generate ultra-short bunches without degrading the beam quality. In the first stage, the beam is compressed with an advanced velocity bunching technique in which the longitudinal phase space is rotated so that electrons on the bunch tail become faster than electrons in the bunch head. In the second stage, the beam is further compressed with a conventional magnetic chicane. With the aid of numerical simulations we show that our two-staged scheme is capable to increase the current of a 50 pC bunch to a notable factor of 100 while the emittance growth can be suppressed to 1% with appropriate tailoring of the initial beam distribution.

  4. Single-bunch beam loading on the SLAC two-mile accelerator

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1976-05-01

    The experiments described were initially prompted by interest in the radiation loss of relativistic electron rings passing through periodic structures. Later the same experiments became relevant to the theory of energy loss of electrons in large storage rings. In both of these cases energy loss to the higher order modes of the respective structures could seriously limit their effective operation. In these experiments, single bunches of electrons with intensities up to 7 x 10 8 electrons per bunch are accelerated through the SLAC three-kilometer accelerator, and their energy spectra are analyzed. Early experiments over a wide energy range (900 MeV to 19 GeV) demonstrated that the energy loss was proportional to the total charge in the bunch but was independent of beam energy. The average energy loss of a single bunch normalized to 10 9 electrons was initially measured to be 38 MeV

  5. Transverse and longitudinal coupled bunch instabilities in trains of closely spaced bunches

    International Nuclear Information System (INIS)

    Thompson, K.A.; Ruth, R.D.

    1989-03-01

    Damping rings for the next generation of linear collider may need to contain several bunch trains within which the bunches are quire closely spaced (1 or 2 RF wavelengths). Methods are presented for studying the transverse and longitudinal coupled bunch instabilities, applicable to this problem and to other cases in which the placement of the bunches is not necessarily symmetric. 5 refs., 1 fig

  6. Collective effects in short bunches: Summary of the Working Group on Proton Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Ruggiero, A.G.

    1990-10-10

    This report discusses the following topics on proton beam bunching: space charge, a collective but incoherent effect; a very short proton bunch; long proton bunches; transition energy crossing; intrabeam scattering; vacuum related effects; and the issue of mode-coupling for proton bunches. (LSP)

  7. Optically controlled laser-plasma electron accelerator for compact gamma-ray sources

    Science.gov (United States)

    Kalmykov, S. Y.; Davoine, X.; Ghebregziabher, I.; Shadwick, B. A.

    2018-02-01

    Generating quasi-monochromatic, femtosecond γ-ray pulses via Thomson scattering (TS) demands exceptional electron beam (e-beam) quality, such as percent-scale energy spread and five-dimensional brightness over 1016 A m-2. We show that near-GeV e-beams with these metrics can be accelerated in a cavity of electron density, driven with an incoherent stack of Joule-scale laser pulses through a mm-size, dense plasma (n 0 ˜ 1019 cm-3). Changing the time delay, frequency difference, and energy ratio of the stack components controls the e-beam phase space on the femtosecond scale, while the modest energy of the optical driver helps afford kHz-scale repetition rate at manageable average power. Blue-shifting one stack component by a considerable fraction of the carrier frequency makes the stack immune to self-compression. This, in turn, minimizes uncontrolled variation in the cavity shape, suppressing continuous injection of ambient plasma electrons, preserving a single, ultra-bright electron bunch. In addition, weak focusing of the trailing component of the stack induces periodic injection, generating, in a single shot, a train of bunches with controllable energy spacing and femtosecond synchronization. These designer e-beams, inaccessible to conventional acceleration methods, generate, via TS, gigawatt γ-ray pulses (or multi-color pulse trains) with the mean energy in the range of interest for nuclear photonics (4-16 MeV), containing over 106 photons within a microsteradian-scale observation cone.

  8. Adiabatic excitation of longitudinal bunch shape oscillations

    Directory of Open Access Journals (Sweden)

    M. Bai

    2000-06-01

    Full Text Available By modulating the rf voltage at near twice the synchrotron frequency, the longitudinal bunch shape can be modulated. This method can be used to shorten bunches. We show experimentally that the bunch shape can be modulated while preserving the longitudinal emittance when the rf voltage modulation is turned on adiabatically. Experimental measurements will be presented along with theoretical predictions.

  9. Electro-optic methods for longitudinal bunch diagnostics at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Steffen, B.R.

    2007-07-15

    Precise measurements of the temporal profile of sub-picosecond electron bunches are of high interest for the optimization and operation of VUV and X-ray free electron lasers. In this thesis, the shortest electro-optic signals measured so far for electron bunch diagnostics are presented, reaching a time resolution of better than 50 fs (rms). The e ects that introduce signal distortions and limit the time resolution are studied in numerical simulations for different electro-optic detection materials and techniques. The time resolution is mainly limited by lattice resonances of the electro-optic crystal. Electro-optic signals as short as 54 fs (rms) are obtained with gallium phosphide (GaP) crystals in a crossed polarizer detection scheme using temporally resolved electro-optic detection. Measuring near crossed polarization, where the electro-optic signal is proportional to the velocity field of the relativistic electron bunch, the shortest obtained signal width is 70 fs (rms). The electro-optic signals are compared to electron bunch shapes that are measured simultaneously with a transverse deflecting structure with 20 fs resolution. Numerical simulations using the bunch shapes as determined with the transverse deflecting cavity as input data are in excellent agreement with electro-optical signals obtained with GaP, both for temporally and spectrally resolved measurements. In the case of zinc telluride (ZnTe) the observed signals are slightly broader and significantly smaller than expected from simulations. These discrepancies are probably due to the poor optical quality of the available ZnTe crystals. (orig.)

  10. Growth of Quantum Wires on Step-Bunched Substrate

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Feng

    2005-02-01

    This proposal initiates a combined theoretical and experimental multidisciplinary research effort to explore a novel approach for growing metallic and magnetic nanowires on step-bunched semiconductor and dielectric substrates, and to lay the groundwork for understanding the growth mechanisms and the electronic, electrical, and magnetic properties of metallic and magnetic nanowires. The research will focus on four topics: (1) fundamental studies of step bunching and self-organization in a strained thin film for creating step-bunched substrates. (2) Interaction between metal adatoms (Al,Cu, and Ni) and semiconductor (Si and SiGe) and dielectric (CaF2) surface steps. (3) growth and characterization of metallic and magnetic nanowires on step-bunched templates. (4) fabrication of superlattices of nanowires by growing multilayer films. We propose to attack these problems at both a microscopic and macroscopic level, using state-of-the-art theoretical and experimental techniques. Multiscale (electronic-atomic-continuum) theories will be applied to investigate growth mechanisms of nanowires: mesoscopic modeling and simulation of step flow growth of strained thin films, in particular, step bunching and self-organization will be carried out within the framework of continuum linear elastic theory; atomistic calculation of interaction between metal adatoms and semiconductor and dielectric surface steps will be done by large-scale computations using first-principles total-energy methods. In parallel, thin films and nanowires will be grown by molecular beam epitaxy (MBE), and the resultant structure and morphology will be characterized at the atomic level up to micrometer range, using a combination of different surface/interface probes, including scanning tunneling microscopy (STM, atomic resolution), atomic force microscopy (AFM, nanometer resolution), low-energy electron microscopy (LEEM, micrometer resolution), reflectance high-energy electron diffraction (RHEED), and x

  11. Electro-optic methods for longitudinal bunch diagnostics at FLASH

    International Nuclear Information System (INIS)

    Steffen, B.R.

    2007-07-01

    Precise measurements of the temporal profile of sub-picosecond electron bunches are of high interest for the optimization and operation of VUV and X-ray free electron lasers. In this thesis, the shortest electro-optic signals measured so far for electron bunch diagnostics are presented, reaching a time resolution of better than 50 fs (rms). The e ects that introduce signal distortions and limit the time resolution are studied in numerical simulations for different electro-optic detection materials and techniques. The time resolution is mainly limited by lattice resonances of the electro-optic crystal. Electro-optic signals as short as 54 fs (rms) are obtained with gallium phosphide (GaP) crystals in a crossed polarizer detection scheme using temporally resolved electro-optic detection. Measuring near crossed polarization, where the electro-optic signal is proportional to the velocity field of the relativistic electron bunch, the shortest obtained signal width is 70 fs (rms). The electro-optic signals are compared to electron bunch shapes that are measured simultaneously with a transverse deflecting structure with 20 fs resolution. Numerical simulations using the bunch shapes as determined with the transverse deflecting cavity as input data are in excellent agreement with electro-optical signals obtained with GaP, both for temporally and spectrally resolved measurements. In the case of zinc telluride (ZnTe) the observed signals are slightly broader and significantly smaller than expected from simulations. These discrepancies are probably due to the poor optical quality of the available ZnTe crystals. (orig.)

  12. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  13. Operational experience with nanocoulomb bunch charges in the Cornell photoinjector

    Directory of Open Access Journals (Sweden)

    Adam Bartnik

    2015-08-01

    Full Text Available Characterization of 9–9.5 MeV electron beams produced in the dc-gun based Cornell photoinjector is given for bunch charges ranging from 20 pC to 2 nC. Comparison of the measured emittances and longitudinal current profiles to optimized 3D space charge simulations yields excellent agreement for bunch charges up to 1 nC when the measured laser distribution is used to generate initial particle distributions in simulation. Analysis of the scaling of the measured emittance with bunch charge shows that the emittance scales roughly as the square root of the bunch charge up to 300 pC, above which the trend becomes linear. These measurements demonstrate that the Cornell photoinjector can produce cathode emittance dominated beams meeting the emittance and peak current specifications for next generation free electron lasers operating at high repetition rate. In addition, the 1 and 2 nC results are relevant to the electron ion collider community.

  14. Operational experience with nanocoulomb bunch charges in the Cornell photoinjector

    Science.gov (United States)

    Bartnik, Adam; Gulliford, Colwyn; Bazarov, Ivan; Cultera, Luca; Dunham, Bruce

    2015-08-01

    Characterization of 9-9.5 MeV electron beams produced in the dc-gun based Cornell photoinjector is given for bunch charges ranging from 20 pC to 2 nC. Comparison of the measured emittances and longitudinal current profiles to optimized 3D space charge simulations yields excellent agreement for bunch charges up to 1 nC when the measured laser distribution is used to generate initial particle distributions in simulation. Analysis of the scaling of the measured emittance with bunch charge shows that the emittance scales roughly as the square root of the bunch charge up to 300 pC, above which the trend becomes linear. These measurements demonstrate that the Cornell photoinjector can produce cathode emittance dominated beams meeting the emittance and peak current specifications for next generation free electron lasers operating at high repetition rate. In addition, the 1 and 2 nC results are relevant to the electron ion collider community.

  15. On energy loss of narrow and dense ultrarelativistic bunch in plasma

    International Nuclear Information System (INIS)

    Kudryavtsev, A.M.; Lotov, K.V.; Skrinsky, A.N.

    1996-01-01

    Energy balance of a particle bunch propagating through the plasma is considered for the bunches of a high density (compared to plasma) and a small radius (compared to anomalous skin depth). Energy loss to scattering of near-axis plasma electrons is estimated. This component of energy balance is shown to be important but not excessively high for the parameters interesting for high energy physics. In particular, the energy loss to near-axis electrons is proved to remain finite as the bunch radius tends to zero [ru

  16. Construction and performance of the magnetic bunch compressor for the THz facility at Chiang Mai University

    International Nuclear Information System (INIS)

    Saisut, J.; Kusoljariyakul, K.; Rimjaem, S.; Kangrang, N.; Wichaisirimongkol, P.; Thamboon, P.; Rhodes, M.W.; Thongbai, C.

    2011-01-01

    The Plasma and Beam Physics Research Facility at Chiang Mai University has established a THz facility to focus on the study of ultra-short electron pulses. Short electron bunches can be generated from a system that consists of a radio-frequency (RF) gun with a thermionic cathode, an alpha magnet as a magnetic bunch compressor, and a linear accelerator as a post-acceleration section. The alpha magnet is a conventional and simple instrument for low-energy electron bunch compression. With the alpha magnet constructed in-house, several hundred femtosecond electron bunches for THz radiation production can be generated from the thermionic RF gun. The construction and performance of the alpha magnet, as well as some experimental results, are presented in this paper.

  17. Therapeutic electrons bunch energy spectrums: correlation among physical parameters and quality; Espectros de energia de feixe de eletrons terapeuticos: correlacao entre parametros fisicos e qualidade

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Rolando Fonseca

    1993-07-01

    A new approach was described for clinical and physical parameters used in radiotherapy planning and dosimetry, studying their dependencies on spectral widths. Two different models of clinical linear accelerators were used-Mevatron 74 (UNICAMP) and Mevatron 12 (HC/FMRP/Ribeirao Preto). Mevatron 74 produces beams with nominal energies from 5 up to 12 MeV and Mevatron 12 from 3 up to 11 MeV. It was verified that the values of clinical parameters expected from a semi-empirical theory differ from that obtained experimentally. Such differences are relevant from the point of view of the design of electron accelerators, as well as, of the target clinical results. (author)

  18. Mutual compensation of wakefield and chromatic effects of intense linac bunches

    International Nuclear Information System (INIS)

    Seeman, J.T.; Merminga, N.

    1990-05-01

    Mutual compensation of transverse and chromatic effects for intense electron bunches in a high-energy linac is a recent Novosibirsk idea which provides a new control of emittance enlargement. In this paper we elaborate on the principles and constraints for this new technique which requires careful matching of internal bunch parameters with external forces. With species values of the bunch length, bunch intensity, and klystron phasing, the transverse-wakefield-induced forces within the bunch can be cancelled by energy-dependent forces from the quadrupole lattice at all positions along the linac. Under these conditions the tolerances for quadrupole alignment, dipole stability, and injection launch errors are significantly relaxed. 7 refs., 8 figs

  19. Direct Numerical Modeling of E-Cloud Driven Instability of a Bunch Train in the CERN SPS

    CERN Document Server

    Vay, J-L; Furman, M A

    2011-01-01

    The simulation package WARP-POSINST was recently upgraded for handling multiple bunches and modeling concurrently the electron cloud buildup and its effect on the beam, allowing for direct self-consistent simulation of bunch trains generating, and interacting with, electron clouds. We have used the WARP-POSINST package on massively parallel supercomputers to study the buildup and interaction of electron clouds with a proton bunch train in the CERN SPS accelerator. Results suggest that a positive feedback mechanism exists between the electron buildup and the e-cloud driven transverse instability, leading to a net increase in predicted electron density.

  20. String formulation of space charge forces in a deflecting bunch

    Directory of Open Access Journals (Sweden)

    Richard Talman

    2004-10-01

    Full Text Available The force between two moving point charges, because of its inverse square law singularity, cannot be applied directly in the numerical simulation of bunch dynamics; radiative effects make this especially true for short bunches being deflected by magnets. This paper describes a formalism circumventing this restriction in which the basic ingredient is the total force on a point charge comoving with a longitudinally aligned, uniformly charged string. Bunch evolution can then be treated using direct particle-to-particle, intrabeam scattering, with no need for an intermediate, particle-in-cell, step. Electric and magnetic fields do not appear individually in the theory. Since the basic formulas are both exact (in paraxial approximation and fully relativistic, they are applicable to beams of all particle types and all energies. But the theory is expected to be especially useful for calculating the emittance growth of the ultrashort electron bunches of current interest for energy recovery linacs and free-electron lasers. The theory subsumes coherent synchrotron radiation and centrifugal space charge force. Renormalized, on-axis, longitudinal field components are in excellent agreement with values from Saldin et al. [DESY Report No. DESY-TESLA-FEL-96-14, 1995; Nucl. Instrum. Methods Phys. Res., Sect. A 417, 158 (1998.NIMAER0168-900210.1016/S0168-9002(9800623-8

  1. Colossal photon bunching in quasiparticle-mediated nanodiamond cathodoluminescence

    Science.gov (United States)

    Feldman, Matthew A.; Dumitrescu, Eugene F.; Bridges, Denzel; Chisholm, Matthew F.; Davidson, Roderick B.; Evans, Philip G.; Hachtel, Jordan A.; Hu, Anming; Pooser, Raphael C.; Haglund, Richard F.; Lawrie, Benjamin J.

    2018-02-01

    Nanoscale control over the second-order photon correlation function g(2 )(τ ) is critical to emerging research in nonlinear nanophotonics and integrated quantum information science. Here we report on quasiparticle control of photon bunching with g(2 )(0 ) >45 in the cathodoluminescence of nanodiamond nitrogen vacancy (NV0) centers excited by a converged electron beam in an aberration-corrected scanning transmission electron microscope. Plasmon-mediated NV0 cathodoluminescence exhibits a 16-fold increase in luminescence intensity correlated with a threefold reduction in photon bunching compared with that of uncoupled NV0 centers. This effect is ascribed to the excitation of single temporally uncorrelated NV0 centers by single surface plasmon polaritons. Spectrally resolved Hanbury Brown-Twiss interferometry is employed to demonstrate that the bunching is mediated by the NV0 phonon sidebands, while no observable bunching is detected at the zero-phonon line. The data are consistent with fast phonon-mediated recombination dynamics, a conclusion substantiated by agreement between Bayesian regression and Monte Carlo models of superthermal NV0 luminescence.

  2. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  3. Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses.

    Science.gov (United States)

    Attenberger, Ulrike I; Rathmann, Nils; Sertdemir, Metin; Riffel, Philipp; Weidner, Anja; Kannengiesser, Stefan; Morelli, John N; Schoenberg, Stefan O; Hausmann, Daniel

    2016-06-01

    Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c

  4. Electron cloud effects in hadron beams

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Fedor; Boine-Frankenheim, Oliver; Weiland, Thomas [TU-Darmstadt, Institut fuer Theorie Elektromagnetischer Felder,Schlossgartenstr. 8 64289 Darmstadt (Germany)

    2013-07-01

    Accelerators operating with intense positively charged beams can suffer from the electron cloud phenomenon. For example, it is the intensity limiting factor in CERN LHC and SPS. In past decades a lot of progress in understanding the electron cloud effects was made worldwide. Methods to suppress or weaken the electron cloud phenomenon were proposed. Theories governing the bunch stability in presence of the electron cloud were developed. Recently the theory was introduced to describe the bunch energy loss due to the electron cloud. However, most of the publications concern the single bunch electron cloud effects. In reality bunches are packed into trains. A disturbance of the cloud caused by the bunch in the beginning of the train affects the subsequent bunches. We present a further investigation of single-bunch electron cloud effects and planned activities to study the phenomenon in case of multiple bunches.

  5. The analysis of bunch production in the oil palm

    NARCIS (Netherlands)

    Sparnaaij, L.D.

    1959-01-01

    Bunch yield of oil palms can be expressed as the product of number of bunches and average bunch weight. Number of bunches is itself composite, being determined by number of leaves, percentage floral abortion, sex ratio and percentage bunch failure. Of these elements sex ratio proved to be most

  6. Bunch Length Measurements in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Fisher, A.; Huang, X.; Safranek, J.; Sebek, J.; /SLAC; Lumpkin, A.; /Argonne; Sannibale, F.; /LBL, Berkeley; Mok, W.; /Unlisted

    2007-11-28

    A series of bunch length measurements were made in SPEAR3 for two different machine optics. In the achromatic optics the bunch length increases from the low-current value of 16.6ps rms to about 30ps at 25ma/bunch yielding an inductive impedance of -0.17{Omega}. Reducing the momentum compaction factor by a factor of {approx}60 [1] yields a low-current bunch length of {approx}4ps rms. In this paper we review the experimental setup and results.

  7. Design and operation of a bunched-beam , phase-spread measurement

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Marquez, H.; Power, J.; Yuan, V.

    1992-01-01

    A bunch-length monitor system has measured the relative changes in the temporal beam-bunch length of an 2.5 MeV H - beam. This system includes a non-interceptive electromagnetic probe, associated RF-processing electronics, and a system-software algorithm. The probe is an axially-symmetric capacitive pickup with output signals proportional to the bunched-beam image currents traveling through its bore. The RF electronics processes the beam-induced signal to obtain the ratio of its fundamental and fifth-harmonic Fourier components and provides a time-varying output voltage proportional to the phase length of the beam bunch. This paper reviews the measurement hardware, software algorithm, and operational experience. (Author) 5 figs., 5 refs

  8. Measurements of Compression and Emittance Growth after the First LCLS Bunch Compressor Chicane

    International Nuclear Information System (INIS)

    Emma, P.

    2007-01-01

    The Linac Coherent Light Source (LCLS) is a SASE xray free-electron laser project presently under construction at SLAC. The injector section from RF photocathode gun through first bunch compressor chicane was installed during the fall of 2006. The first bunch compressor is located at 250 MeV and nominally compresses a 1-nC electron bunch from an rms length of about 1 mm to 0.2 mm. Transverse phase space and bunch length diagnostics are located immediately after the chicane. We present preliminary measurements and simulations of the longitudinal and transverse phase space after the chicane in various beam conditions, including extreme compression with micron-scale current spikes

  9. Electro-optic sampling at 90 degree interaction geometry for time-of-arrival stamping of ultrafast relativistic electron diffraction

    Directory of Open Access Journals (Sweden)

    C. M. Scoby

    2010-02-01

    Full Text Available In this paper we study a new geometry setup for electro-optic sampling (EOS where the electron beam runs parallel to the ⟨110⟩ face of a ZnTe crystal and the probe laser is perpendicular to it and to the beam path. The simple setup is used to encode the time-of-arrival information of a 3.5  MeV<10  pC electron bunch on the spatial profile of the laser pulse. The electric field lines inside the dielectric bend at an angle due to a relatively large (n∼3 index of refraction of the ZnTe crystal. We found theoretically and experimentally that the EOS signal can be maximized with a proper choice of incoming laser polarization angle. We achieved single-shot nondestructive measurement of the relative time of arrival between the pump and the probe beams thus improving the temporal resolution of ultrafast relativistic electron diffraction experiments.

  10. Interscalene brachial plexus block for open-shoulder surgery: a randomized, double-blind, placebo-controlled trial between single-shot anesthesia and patient-controlled catheter system.

    Science.gov (United States)

    Goebel, Sascha; Stehle, Jens; Schwemmer, Ulrich; Reppenhagen, Stephan; Rath, Beatrice; Gohlke, Frank

    2010-04-01

    Interscalene brachial plexus block (ISB) is widely used as an adjuvant regional pain therapy in patients undergoing major shoulder surgery and has proved its effectiveness on postoperative pain reduction and opioid-sparing effect. This single-center, prospective, double-blind, randomized and placebo-controlled study was to compare the effectiveness of a single-shot and a patient-controlled catheter insertion ISB system after major open-shoulder surgeries. Seventy patients were entered to receive an ISB and a patient-controlled interscalene catheter. The catheter was inserted under ultrasound guidance. Patients were then assigned to receive one of two different postoperative infusions, either 0.2% ropivacaine (catheter group) or normal saline solution (single-shot group) via a disposable patient-controlled infusion pump. The study variables were amount of rescue medication, pain at rest and during physiotherapy, patient satisfaction and incidence of unwanted side effects. The ropivacaine group revealed significantly less consumption of rescue medication within the first 24 h after surgery. Incidence of side effects did not differ between the two groups. Based on our results, we recommend the use of interscalene plexus block in combination with a patient-controlled catheter system under ultrasound guidance only for the first 24 h after major open-shoulder surgery.

  11. Unwinding in Hopfion vortex bunches

    Science.gov (United States)

    Jäykkä, Juha; Hietarinta, Jarmo

    2009-06-01

    We investigate the behavior of parallel Faddeev-Hopf vortices under energy minimization in a system with physically relevant, but unusual boundary conditions. The homotopy classification is no longer provided by the Hopf invariant, but rather by the set of integer homotopy invariants proposed by Pontrjagin. The nature of these invariants depends on the boundary conditions. A set of tightly wound parallel vortices of the usual Hopfion structure is observed to form a bunch of intertwined vortices or unwind completely, depending on the boundary conditions.

  12. Preliminary result of bunch length measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Lin Xuling; Luo Feng; Bei Hua; Dai Zhimin; Chinese Academy of Sciences, Beijing; Zhang Jianbing; Lu Shanliang; Yu Tiemin

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper. (authors)

  13. 107th meeting of the working group electronic instrumentation in Spring 2016

    International Nuclear Information System (INIS)

    Goettlicher, Peter

    2016-06-01

    The following topics were dealt with: Instrumentation and the NUSTAR physics program in FAIR phase-0, actual projects of the group EE-digital electronics, ethernet-based data acquisition beyond 10 GBit/s, the big data problem in DAQ systems, a general front-end readout architecture in scientific detector systems, the KALYPSO detection system for single-shot electro-optical bunch measurements, MicroTCA based RF and laser cavity regulation including piezo controls, FPGA implementation for data acquisition system with gigabit serial link and PCIe interface, next generation MTCA.4 crate, increased PCIexpress band-width up to 128 Gb/s and optical PCIexpress cascading, power supplies for the sensitive measurement techniques and the complex automatization, error-save industry PC, the interfacing of NI products to EPICS, Green Cube, a survey of EPICS rate at GSI and FAIR, CS++ as actor-based successor of the CS framework, synchronized fast shutter control with adaptive phase shift compensation in the EtherCAT motion control system, precise voltage supply for the SiPM of a Cherenkov telescope in the Antarctis, development of a multichannel readout hardware for delay-line neutron detectors, silicon photonic data transmission for detector instrumentation, EMV consideration of the Maria instrument at the FRM2, quench detectors for FAIR, optimized illumination and in-situ calibration of high-gain antennas for the detection of extensive cosmic air showers. (HSI)

  14. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    Energy Technology Data Exchange (ETDEWEB)

    Gribkov, V A; Latyshev, S V [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Miklaszewski, R A; Chernyshova, M [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Drozdowicz, K; Wiacek, U [Institute of Nuclear Physics, Krakow (Poland); Tomaszewski, K [ACS Ltd, Warsaw (Poland); Lemeshko, B D [N L Dukhov All-Russian Institute of Automation, Moscow (Russian Federation)], E-mail: gribkovv@yahoo.com

    2010-03-15

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity ({delta}E/E{approx}1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 10{sup 8}-10{sup 9} 2.45 MeV and 10{sup 10}-10{sup 11} 14 MeV neutrons per pulse with pulse duration {approx}10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation-1 litre bottles with methanol (CH{sub 3}OH), phosphoric (H{sub 2}PO{sub 4}) and nitric (HNO{sub 3}) acids as well as a long object-a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  15. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    International Nuclear Information System (INIS)

    Gribkov, V A; Latyshev, S V; Miklaszewski, R A; Chernyshova, M; Drozdowicz, K; Wiacek, U; Tomaszewski, K; Lemeshko, B D

    2010-01-01

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity (ΔE/E∼1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 10 8 -10 9 2.45 MeV and 10 10 -10 11 14 MeV neutrons per pulse with pulse duration ∼10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation-1 litre bottles with methanol (CH 3 OH), phosphoric (H 2 PO 4 ) and nitric (HNO 3 ) acids as well as a long object-a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  16. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    Science.gov (United States)

    Gribkov, V. A.; Latyshev, S. V.; Miklaszewski, R. A.; Chernyshova, M.; Drozdowicz, K.; Wiącek, U.; Tomaszewski, K.; Lemeshko, B. D.

    2010-03-01

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity (ΔE/E~1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 108-109 2.45 MeV and 1010-1011 14 MeV neutrons per pulse with pulse duration ~10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation—1 litre bottles with methanol (CH3OH), phosphoric (H2PO4) and nitric (HNO3) acids as well as a long object—a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  17. TRANSVERSE MODES FOR FLAT INTER-BUNCH WAKES*

    CERN Document Server

    Burov, A

    2013-01-01

    If inter-bunch wake fields are flat, i.e. their variations over a bunch length can be neglected, all coherent modes have the same coupled-bunch structure, provided the bunches can be treated as identical by their inner qualities (train theorem). If a flat feedback is strong enough, the transverse modes are single-bunch, provided the inter-bunch wakes are also flat (damper theorem).

  18. Correlation between morphological characters and estimated bunch ...

    African Journals Online (AJOL)

    The methodology of multiple linear regression (MLR) was used to estimate bunch weight. The most significant variables that were measured included number of leaves at harvest, number of fruits per bunch, FW, FL, rachis weight (RW) and stalk length (SL), generating the following prediction equation: BW= -5.249 + ...

  19. LHC MD 1279: Bunch Flattening in Physics

    CERN Document Server

    AUTHOR|(CDS)2073675; Baudrenghien, Philippe; Esteban Muller, Juan; Shaposhnikova, Elena; CERN. Geneva. ATS Department

    2017-01-01

    Vertex reconstruction is not accurate enough for LHCb when the bunch length in physics shrinks below about 0.9 ns. The end-of-fill MD studies presented here proved that bunch flattening using sinusoidal RF modulation is a loss-free method to increase the r.m.s. bunch length and flatten the bunch profile. Furthermore, the optimum modulation parameters to be used in physics have been identified. Subsequently, bunch flattening in physics was used operationally with a modulation frequency of 98.75 % of the central synchrotron frequency and 0.6 modulation amplitude, resulting in a 150-200 ps increase in the BQM-measured bunch length. A ‘mid-of-fill’ test at arrival to flat top revealed that also the bunch distribution created by the controlled emittance blow-up during the ramp is affected when bunch flattening is applied. The measurements took place on 17th June and the 4th, 7th and 22nd July 2016. Operational cases are shown as well.

  20. Study of Bunch by Bunch Feedback System in TRISTAN-AR

    Science.gov (United States)

    Tobiyama, M.; Kikutani, E.

    1997-05-01

    Beam tests of the KEKB bunch by bunch feedback system prototypes have been performed in the TRISTAN-AR on both longitudinal and transverse planes. Both bunch detection systems are capable to distinguish the individual bunches with the minimum bunch spacing of 2 ns. A two-tap FIR filter system consisting of hardware logic's realized the function of the phase shift by 90 degrees, the suppression of the static component and the delay of up to a few tens of turns in longitudinal plane with 508 MHz of system clock. The transverse systems were purely analog system without any digital signal processing part. Four cells of series-drift-tube type kickers just same structure as used in ALS at LBNL have been employed for the longitudinal kicker, and simple stripline kickers have been used for the transverse kicker. Both feedback system worked well as expected. More than 100 bunches with maximum current of 376 mA have been accumulated successfully with the bunch spacing of 2 ns. Without the system, it was impossible to accumulate more than 20 bunches with the same bunch current. The growth time and the growing modes of the transverse instabilities has also been measured with the memory function of the two-tap FIR filter. It suggests that the bunch-by-bunch feedback system is a powerful tool to explore the source of the instabilities.

  1. Bunch lengthening calculations for the SLC [Stanford Linear Collider] damping rings

    International Nuclear Information System (INIS)

    Bane, K.L.F.; Ruth, R.D.

    1989-03-01

    The problem of bunch lengthening in electron storage rings has been treated by many people, and there have been many experiments. In the typical experiment, the theory is used to determine the impedance of the ring. What has been lacking thus far, however, is a calculation of bunch lengthening that uses a carefully calculated ring impedance (or wakefield). In this paper we begin by finding the potential well distortion due to some very simple impedance models, in order to illustrate different types of bunch lengthening behavior. We then give a prescription for extending potential well calculations into the turbulent regime once the threshold is known. Then finally, using the wakefield calculated for the SLC damping rings, combined with the measured value of the threshold, we calculate bunch lengthening for the damping rings, and compare the results with the measurements. 9 refs., 6 figs

  2. Emittance control and RF bunch compression in the NSRRC photoinjector

    International Nuclear Information System (INIS)

    Lau, W.K.; Hung, S.B.; Lee, A.P.; Chou, C.S.; Huang, N.Y.

    2011-01-01

    The high-brightness photoinjector being constructed at the National Synchrotron Radiation Research Center is for testing new accelerator and light-source concepts. It is the so-called split photoinjector configuration in which a short solenoid magnet is used for emittance compensation. The UV-drive laser pulses are also shaped to produce uniform cylindrical bunches for further reduction of beam emittance. However, limited by the available power from our microwave power system, the nominal accelerating gradient in the S-band booster linac is set at 18 MV/m. A simulation study with PARMELA shows that the linac operating at this gradient fails to freeze the electron beam emittance at low value. A background solenoid magnetic field is applied for beam emittance control in the linac during acceleration. A satisfactory result that meets our preliminary goal has been achieved with the solenoid magnetic field strength at 0.1 T. RF bunch compression as a means to achieve the required beam brightness for high-gain free-electron laser experiments is also examined. The reduction of bunch length to a few hundred femtoseconds can be obtained.

  3. Observation of Electron Cloud Instabilities and Emittance Dilution at the Cornell Electron-Positron Storage Ring Test Accelerator

    International Nuclear Information System (INIS)

    Holtzapple, R.L.; Campbell, R.C.; McArdle, K.E.; Miller, M.I.; Totten, M.M.; Tucker, S.L.; Billing, M.G.; Dugan, G.F.; Ramirez, G.A.; Sonnad, K.G.; Williams, H.A.; Flanagan, J.; Palmer, M.A.

    2016-01-01

    Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnotics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains; 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this paper we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions

  4. Observation of Electron Cloud Instabilities and Emittance Dilution at the Cornell Electron-Positron Storage Ring Test Accelerator

    Science.gov (United States)

    Holtzapple, R. L.; Billing, M. G.; Campbell, R. C.; Dugan, G. F.; Flanagan, J.; McArdle, K. E.; Miller, M. I.; Palmer, M. A.; Ramirez, G. A.; Sonnad, K. G.; Totten, M. M.; Tucker, S. L.; Williams, H. A.

    2016-04-01

    Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnotics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains; 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this paper we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions.

  5. A compact source for bunches of singly charged atomic ions

    Science.gov (United States)

    Murböck, T.; Schmidt, S.; Andelkovic, Z.; Birkl, G.; Nörtershäuser, W.; Vogel, M.

    2016-04-01

    We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 106 Mg+ ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg+ ions for sympathetic cooling of highly charged ions by laser-cooled 24Mg+.

  6. Bunch-motion feedback for B-factories

    International Nuclear Information System (INIS)

    Lambertson, G.R.

    1992-09-01

    The colliding electron and positron beams in a B-factory must have average current of one ampere or more to produce the required luminosity. The high current interacts with structures in the beam tube to drive strong coupled-bunch (c.b.) instabilities. To suppress these instabilities requires negative feedback of the bunch motions. Beam impedances arising from strong rf cavity modes should first be reduced to make the required feedback damping rate practical and the cost economical. In what follows, control of transverse motions will be discussed first, then longitudinal. We shall use the parameters of the 3.1 GeV ring of PEP-II to illustrate the general requirements

  7. Study of CSR longitudinal bunch compression cavity

    International Nuclear Information System (INIS)

    Yin Dayu; Li Peng; Liu Yong; Xie Qingchun

    2009-01-01

    The scheme of longitudinal bunch compression cavity for the Cooling Storage Ring (CSR)is an important issue. Plasma physics experiments require high density heavy ion beam and short pulsed bunch,which can be produced by non-adiabatic compression of bunch implemented by a fast compression with 90 degree rotation in the longitudinal phase space. The phase space rotation in fast compression is initiated by a fast jump of the RF-voltage amplitude. For this purpose, the CSR longitudinal bunch compression cavity, loaded with FINEMET-FT-1M is studied and simulated with MAFIA code. In this paper, the CSR longitudinal bunch compression cavity is simulated and the initial bunch length of 238 U 72+ with 250 MeV/u will be compressed from 200 ns to 50 ns.The construction and RF properties of the CSR longitudinal bunch compression cavity are simulated and calculated also with MAFIA code. The operation frequency of the cavity is 1.15 MHz with peak voltage of 80 kV, and the cavity can be used to compress heavy ions in the CSR. (authors)

  8. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    International Nuclear Information System (INIS)

    Azima, Armin

    2009-07-01

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  9. An electro-optical timing diagnostic for pump-probe experiments at the free-electron laser in Hamburg FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Azima, Armin

    2009-07-15

    Femtosecond pump-probe experiments have extensively been used to follow atomic and molecular motion in time. The very intense extreme ultraviolet XUV light of the Free electron LASer in Hamburg FLASH facility allows to investigate fundamental processes such as direct one or few photon inner shell ionizations. A supplementary Ti:Sapphire near infrared femtosecond laser system allows to perform two-color pump-probe experiments with FLASH involving intense laser fields of hugely different photon energies. Within this work a bunch arrival measurement system has been built, which assists these two-color pump-probe experiments to reduce the temporal jitter of FLASH and to increase the temporal resolution. The diagnostic is based upon an electro-optical detection scheme and measures the relative arrival time between the Ti:Sapphire femtosecond pulse and the electron bunch, which generates the self-amplified by stimulated emission SASE XUV pulse in the undulator section of FLASH. Key feature of the diagnostic is a 150 m long glass fiber pulse transport line, which inflicts non-linear dispersion. A dispersion control system to compensate for this higher order dispersion has been developed including the control and programming of a spatial light phase modulator. It was possible to transport a 90 fs FWHM short near infrared femtosecond laser pulse Fourier limited by the dispersion compensated glass fiber. The electro-optical signal induced by the FLASH electron bunch was generated, characterized and optimized. The signal features beside the designated bunch arrival timing capability the additional possibility to measure the longitudinal electron bunch density distribution of an arbitrary bunch of FLASH in a single shot with a temporal resolution of below 100 fs RMS. Timing and bunch analysis capabilities of the developed diagnostic have been cross-checked with other comparable diagnostics at FLASH like the transversal deflecting cavity structure named LOLA. Finally, the

  10. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  11. Operation of LEP with bunch trains

    CERN Document Server

    Collier, Paul; Lamont, M

    1996-01-01

    Following an intensive MD program in 1994, a bunch train scheme was adopted as the operational mode for LEP. The configuration was used throughout 1995 and produced record luminosities. The year culminated in a high energy bunch train run which produced encouraging results for LEP2. In spite of this, the bunch train scheme met with varying degrees of success and the overall performance was not as good as expected. The performance of the machine is presented, together with the problems encountered and the various optimisation techniques used. The performance of related hardware and instrumentation is discussed.

  12. Down sampled signal processing for a B Factory bunch-by-bunch feedback system

    International Nuclear Information System (INIS)

    Hindi, H.; Hosseini, W.; Briggs, D.; Fox, J.; Hutton, A.

    1992-03-01

    A bunch-by-bunch feedback scheme is studied for damping coupled bunch synchrotron oscillations in the proposed PEP II B Factory. The quasi-linear feedback systems design incorporates a phase detector to provide a quantized measure of bunch phase, digital signal processing to compute an error correction signal and a kicker system to correct the energy of the bunches. A farm of digital processors, operating in parallel, is proposed to compute correction signals for the 1658 bunches of the B Factory. This paper studies the use of down sampled processing to reduce the computational complexity of the feedback system. We present simulation results showing the effect of down sampling on beam dynamics. Results show that down sampled processing can reduce the scale of the processing task by a factor of 10

  13. Polarized e-bunch acceleration at Cornell RCS: Tentative tracking simulations

    Energy Technology Data Exchange (ETDEWEB)

    Meot, F. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ptitsyn, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ranjbar, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rubin, D. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-10-19

    An option as an injector into eRHIC electron storage ring is a rapid-cyclic synchrotron (RCS). Rapid acceleration of polarized electron bunches has never been done, Cornell synchrotron might lend itself to dedicated tests, which is to be first explored based on numerical investigations. This paper is a very preliminary introduction to the topic.

  14. HOM Effects in Vacuum System with Short Bunches

    CERN Document Server

    Novokhatski, Alexander

    2005-01-01

    High luminosity in electron-positron factories requires high beam currents of very short bunches. SLAC PEP-II and KEKB B-factories are progressively increasing currents and gaining more and more luminosity. Because of this the interaction of high currents and vacuum chamber elements becomes more important for the operation of the rings. High Order Modes (HOM) excited by short intense bunches propagate along the vacuum chamber, penetrating and dissipating inside vital vacuum elements like shielded bellows, vacuum valves and vacuum pumps. As a result these elements can heat up or have temperature oscillations. Often HOM heating has a resonance character. HOM heating of vacuum pumps can lead to vacuum pressure increases. High frequency modes excited by short bunches “check” the quality of the vacuum chamber by detecting small gaps, weak RF screens or weak feed-through. At these high currents even smooth tapers and smooth collimators become a source of HOM production. We will discuss the physi...

  15. Characterization of pseudosingle bunch kick-and-cancel operational mode

    Directory of Open Access Journals (Sweden)

    C. Sun

    2015-12-01

    Full Text Available Pseudosingle-bunch kick-and-cancel (PSB-KAC is a new operational mode at the Advanced Light Source of Lawrence Berkeley National Laboratory that provides full timing and repetition rate control for single x-ray pulse users while being fully transparent to other users of synchrotron radiation light. In this operational mode, a single electron bunch is periodically displaced from a main bunch train by a fast kicker magnet with a user-on-demand repetition rate, creating a single x-ray pulse to be matched to a typical laser excitation pulse rate. This operational mode can significantly improve the signal to noise ratio of single x-ray pulse experiments and drastically reduce dose-induced sample damage rate. It greatly expands the capabilities of synchrotron light sources to carry out dynamics and time-of-flight experiments. In this paper, we carry out extensive characterizations of this PSB-KAC mode both numerically and experimentally. This includes the working principle of this mode, resonance conditions and beam stability, experimental setups, and diagnostic tools and measurements.

  16. Characterization of pseudosingle bunch kick-and-cancel operational mode

    Science.gov (United States)

    Sun, C.; Robin, D. S.; Steier, C.; Portmann, G.

    2015-12-01

    Pseudosingle-bunch kick-and-cancel (PSB-KAC) is a new operational mode at the Advanced Light Source of Lawrence Berkeley National Laboratory that provides full timing and repetition rate control for single x-ray pulse users while being fully transparent to other users of synchrotron radiation light. In this operational mode, a single electron bunch is periodically displaced from a main bunch train by a fast kicker magnet with a user-on-demand repetition rate, creating a single x-ray pulse to be matched to a typical laser excitation pulse rate. This operational mode can significantly improve the signal to noise ratio of single x-ray pulse experiments and drastically reduce dose-induced sample damage rate. It greatly expands the capabilities of synchrotron light sources to carry out dynamics and time-of-flight experiments. In this paper, we carry out extensive characterizations of this PSB-KAC mode both numerically and experimentally. This includes the working principle of this mode, resonance conditions and beam stability, experimental setups, and diagnostic tools and measurements.

  17. Direct longitudinal laser acceleration of electrons in free space

    Directory of Open Access Journals (Sweden)

    Sergio Carbajo

    2016-02-01

    Full Text Available Compact laser-driven accelerators are pursued heavily worldwide because they make novel methods and tools invented at national laboratories widely accessible in science, health, security, and technology [V. Malka et al., Principles and applications of compact laser-plasma accelerators, Nat. Phys. 4, 447 (2008]. Current leading laser-based accelerator technologies [S. P. D. Mangles et al., Monoenergetic beams of relativistic electrons from intense laser-plasma interactions, Nature (London 431, 535 (2004; T. Toncian et al., Ultrafast laser-driven microlens to focus and energy-select mega-electron volt protons, Science 312, 410 (2006; S. Tokita et al. Single-shot ultrafast electron diffraction with a laser-accelerated sub-MeV electron pulse, Appl. Phys. Lett. 95, 111911 (2009] rely on a medium to assist the light to particle energy transfer. The medium imposes material limitations or may introduce inhomogeneous fields [J. R. Dwyer et al., Femtosecond electron diffraction: “Making the molecular movie,”, Phil. Trans. R. Soc. A 364, 741 (2006]. The advent of few cycle ultraintense radially polarized lasers [S. Carbajo et al., Efficient generation of ultraintense few-cycle radially polarized laser pulses, Opt. Lett. 39, 2487 (2014] has ushered in a novel accelerator concept [L. J. Wong and F. X. Kärtner, Direct acceleration of an electron in infinite vacuum by a pulsed radially polarized laser beam, Opt. Express 18, 25035 (2010; F. Pierre-Louis et al. Direct-field electron acceleration with ultrafast radially polarized laser beams: Scaling laws and optimization, J. Phys. B 43, 025401 (2010; Y. I. Salamin, Electron acceleration from rest in vacuum by an axicon Gaussian laser beam, Phys. Rev. A 73, 043402 (2006; C. Varin and M. Piché, Relativistic attosecond electron pulses from a free-space laser-acceleration scheme, Phys. Rev. E 74, 045602 (2006; A. Sell and F. X. Kärtner, Attosecond electron bunches accelerated and

  18. A coupled bunch instability due to beam-photoelectron interactions in KEKB-LER

    Energy Technology Data Exchange (ETDEWEB)

    Ohmi, Kazuhito [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1996-08-01

    LER of KEKB is designed to storage the positron beam of 2.6 A with multibunch operation. Nb = 3.3 x 10{sup 10} positrons are filled in a bunch and the bunch passes every 2ns through a beam chamber. The photoelectron instability may be serious for KEKB-LER. We consider a motion of photoelectrons produced by a bunch with a computer simulation technic. A cylindrical chamber with a diameter of 10 cm was used as a model chamber. About 15 times of the photoelectrons were produced by a bunch. The wake force was calculated for the loading bunches with displacements of 0.5 mm and 1 mm. The wake characteristics seems to be caused by the trapped electrons kicked by the loading bunch. The wake was saturated with the loading displacement of 0.5 mm. We obtained a growth rate by the wake force. It is very high rate, 2500s{sup -1} which exceeds damping rates of various mechanism, radiation, head-tail and feedback. Perhaps it is essential to remove the photoelectrons around the positron beam explicitly. If we apply magnetic field fo about 20 G, the growth rate will be reduced. (S.Y.)

  19. Use of a corrugated beam pipe as a passive deflector for bunch length measurements

    Science.gov (United States)

    Seok, Jimin; Chung, Moses; Kang, Heung-Sik; Min, Chang-Ki; Na, Donghyun

    2018-02-01

    We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch's longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The astra and elegant simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive) rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL) Injector Test Facility (ITF), and its results are discussed together with a comparison with the rf deflector measurement.

  20. Considerations of bunch-spacing options for multi-bunch operation of the Tevatron Collider

    International Nuclear Information System (INIS)

    Dugan, G.

    1989-01-01

    This discussion will consider a number of points relevant to limitations, advantages and disadvantages of various arrangements of bunches in the Tevatron proton-antiproton collider. The considerations discussed here will be limited to: (a) bunch spacing symmetry and relation to the relative luminosity at B0 and D0 and the beam-beam interaction with separated beams; (b) bunch spacing constraints imposed by Main Ring RF coalescing and the optics of beam separation at B0 and D0; and (c) bunch spacing constraints imposed by injection and abort kicker timing requirements, and by the Antiproton Source RF unstacking process. 20 figs., 17 tabs

  1. Space Charge Mitigation by Hollow Bunches

    CERN Multimedia

    Oeftiger, AO

    2014-01-01

    To satisfy the requirements of the HL-LHC (High Luminosity Large Hadron Collider), the LHC injector chain will need to supply a higher brightness, i.e. deliver the same transverse beam emittances \\epsilon_{x,y} while providing a higher intensity N. However, a larger number of particles per bunch enhances space charge effects. One approach to mitigate the impact of space charge is to change the longitudinal phase space distribution: hollow bunches feature a depleted bunch centre and a densely populated periphery. Thus, the spatial line density maximum is depressed which ultimately decreases the tune spread imposed by space charge. Therefore, a higher intensity can be accepted while keeping the same overall space charge tune shift. 3 different methods to create hollow bunches in the PSBooster are simulated.

  2. Space Charge Mitigation With Longitudinally Hollow Bunches

    CERN Multimedia

    Oeftiger, Adrian; Rumolo, Giovanni

    2016-01-01

    Hollow longitudinal phase space distributions have a flat profile and hence reduce the impact of transverse space charge. Dipolar parametric excitation with the phase loop feedback systems provides such hollow distributions under reproducible conditions. We present a procedure to create hollow bunches during the acceleration ramp of CERN’s PS Booster machine with minimal changes to the operational cycle. The improvements during the injection plateau of the downstream Proton Synchrotron are assessed in comparison to standard parabolic bunches.

  3. Submicron multi-bunch BPM for CLIC

    CERN Document Server

    Schmickler, H.; Lunin, A.; Solyak, N.; Wendt, M.

    2010-01-01

    A common-mode free cavity BPM is currently under development at Fermilab within the ILC-CLIC collaboration. This monitor will be operated in a CLIC Main Linac multi-bunch regime, and needs to provide both, high spatial and time resolution. We present the design concept, numerical analysis, investigation on tolerances and error effects, as well as simulations on the signal response applying a multi-bunch stimulus.

  4. Space charge mitigation with longitudinally hollow bunches

    CERN Document Server

    AUTHOR|(CDS)2088716; Hancock, Steven; Rumolo, Giovanni; CERN. Geneva. ATS Department

    2016-01-01

    Suitably, hollow longitudinal phase space distributions have a flat profile and hence reduce the impact of transverse space charge. Dipolar parametric excitation with the phase loop feedback systems provides such hollow distributions under reproducible conditions. We present a procedure to create hollow bunches during the acceleration ramp of CERN’s PS Booster machine with minimal changes to the operational cycle. The improvements during the injection plateau of the downstream Proton Synchrotron are assessed in comparison to standard parabolic bunches.

  5. Bunch length monitor using two-frequency analysis for RF gun system

    International Nuclear Information System (INIS)

    Kuroda, Ryunosuke; Kashiwagi, Shigeru; Sakaue, Kazuyuki; Washio, Masakazu; Hayano, Hitoshi; Urakawa, Junji

    2004-01-01

    An rms (root mean square) bunch length monitor for a laser-driven photocathode rf gun system on a two-frequency analysis technique has been developed. Typically, the photoelectron beam generated from the rf gun system has an energy of 3-5 MeV and an rms bunch length smaller than 20 ps down to 3-4 ps. This monitor is suitable for such electron beam measurement. The rms bunch length as a function of rf phase was experimentally measured using both the rms bunch length monitor and streak camera technique using a 50 MeV electron beam at the KEK accelerator test facility (KEK-ATF) injector section which has an rf gun system and a 3-m-long accelerator structure. A numerical simulation study was also performed using the PARMELA code. The availability of this monitor was clearly verified by comparing the results. Consequently, this monitor was installed in the rf gun system at Waseda University and the rms bunch length measurement for a 3.5 MeV electron beam was precisely performed using the monitor. (author)

  6. 107th meeting of the working group electronic instrumentation in Spring 2016; 107. Tagung der Studiengruppe elektronische Instrumentierung im Fruehjahr 2016

    Energy Technology Data Exchange (ETDEWEB)

    Goettlicher, Peter (ed.)

    2016-06-15

    The following topics were dealt with: Instrumentation and the NUSTAR physics program in FAIR phase-0, actual projects of the group EE-digital electronics, ethernet-based data acquisition beyond 10 GBit/s, the big data problem in DAQ systems, a general front-end readout architecture in scientific detector systems, the KALYPSO detection system for single-shot electro-optical bunch measurements, MicroTCA based RF and laser cavity regulation including piezo controls, FPGA implementation for data acquisition system with gigabit serial link and PCIe interface, next generation MTCA.4 crate, increased PCIexpress band-width up to 128 Gb/s and optical PCIexpress cascading, power supplies for the sensitive measurement techniques and the complex automatization, error-save industry PC, the interfacing of NI products to EPICS, Green Cube, a survey of EPICS rate at GSI and FAIR, CS++ as actor-based successor of the CS framework, synchronized fast shutter control with adaptive phase shift compensation in the EtherCAT motion control system, precise voltage supply for the SiPM of a Cherenkov telescope in the Antarctis, development of a multichannel readout hardware for delay-line neutron detectors, silicon photonic data transmission for detector instrumentation, EMV consideration of the Maria instrument at the FRM2, quench detectors for FAIR, optimized illumination and in-situ calibration of high-gain antennas for the detection of extensive cosmic air showers. (HSI)

  7. Analysis of longitudinal bunching in an FEL driven two-beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lidia, S.; Gardelle, J.; Lefevre, T.; Donohue, J.T.; Gouard, P.; Rullier, J.L.; Vermare, C.

    2000-08-01

    Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.

  8. Analysis of longitudinal bunching in an FEL driven two-beam accelerator

    International Nuclear Information System (INIS)

    Lidia, S.; Gardelle, J.; Lefevre, T.; Donohue, J.T.; Gouard, P.; Rullier, J.L.; Vermare, C.

    2000-01-01

    Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam

  9. Bunch-Crossing Identification for saturated calorimeter signals

    CERN Document Server

    Pfeiffer, Ullrich

    1999-01-01

    This paper describes an algorithm, which will be implemented in the Preprocessor ASIC of the ATLAS Level-1 Calorimeter trigger. Its purpose is to identify the corresponding Bunch-Crossing in time for saturated trigger tower signals from the calorimeters (saturated BCID). Results presented here are combined from simulations with a PSPICE model of the Liquid Argon trigger tower electronics and the digital signal processing inside the Preprocessor. The PSPICE model describes saturation of analogue pulses in a realistic way. The digital processing allows to investigate noise effects and shifts of the digitization strobe of the FADC against the pulse position.

  10. Bunch length and the 102/90 degrees optics

    CERN Document Server

    Lamont, M

    1998-01-01

    The bunch length in LEP has become a cause for concern, particularly in the ramp to high energies. Short bunch lengths excite higher order modes which can cause heating of the inter-cavity bellows a nd may be picked up by antennae cables causing burning. The bunch length is also important from a cryogenics viewpoint; HOM losses go up with shorter bunches and more cryogenics power is required. Measurements made during 1997 show that it is strongly advisable to maintain bunch lengths above 9 mm particularly with high bunch currents. The use of a low emittance lattice such as 102/90 degr ees exacerbates the problem; because of the decreased momentum compaction the bunch lengths are naturally shorter. This paper quantifies the bunch lengths to be expected at various stages of ope ration in 1998 and presents recommendations for the avoidance of bunch lengths shorter than 9 mm.

  11. Computer modelling of bunch-by-bunch feedback for the SLAC B-factory design

    International Nuclear Information System (INIS)

    Briggs, D.; Fox, J.D.; Hosseini, W.; Klaisner, L.; Morton, P.; Pellegrin, J.L.; Thompson, K.A.; Lambertson, G.

    1991-05-01

    The SLAC B-factory design, with over 1600 high current bunches circulating in each ring, will require a feedback system to avoid coupled-bunch instabilities. A computer model of the storage ring, including the RF system, wave fields, synchrotron radiation loss, and the bunch-by-bunch feedback system is presented. The feedback system model represents the performance of a fast phase detector front end (including system noise and imperfections), a digital filter used to generate a correction voltage, and a power amplifier and beam kicker system. The combined ring-feedback system model is used to study the feedback system performance required to suppress instabilities and to quantify the dynamics of the system. Results are presented which show the time development of coupled bunch instabilities and the damping action of the feedback system. 3 refs., 5 figs., 2 tabs

  12. Dense Plasma Focus: physics and applications (radiation material science, single-shot disclosure of hidden illegal objects, radiation biology and medicine, etc.)

    Science.gov (United States)

    Gribkov, V. A.; Miklaszewski, R.; Paduch, M.; Zielinska, E.; Chernyshova, M.; Pisarczyk, T.; Pimenov, V. N.; Demina, E. V.; Niemela, J.; Crespo, M.-L.; Cicuttin, A.; Tomaszewski, K.; Sadowski, M. J.; Skladnik-Sadowska, E.; Pytel, K.; Zawadka, A.; Giannini, G.; Longo, F.; Talab, A.; Ul'yanenko, S. E.

    2015-03-01

    The paper presents some outcomes obtained during the year of 2013 of the activity in the frame of the International Atomic Energy Agency Co-ordinated research project "Investigations of Materials under High Repetition and Intense Fusion-Relevant Pulses". The main results are related to the effects created at the interaction of powerful pulses of different types of radiation (soft and hard X-rays, hot plasma and fast ion streams, neutrons, etc. generated in Dense Plasma Focus (DPF) facilities) with various materials including those that are counted as perspective ones for their use in future thermonuclear reactors. Besides we discuss phenomena observed at the irradiation of biological test objects. We examine possible applications of nanosecond powerful pulses of neutrons to the aims of nuclear medicine and for disclosure of hidden illegal objects. Special attention is devoted to discussions of a possibility to create extremely large and enormously diminutive DPF devices and probabilities of their use in energetics, medicine and modern electronics.

  13. A Drive Laser for Multi-Bunch Photoinjector Operation

    Energy Technology Data Exchange (ETDEWEB)

    Gibson, D J; Cormier, E; Messerly, M J; Prantil, M A; Barty, C J

    2012-05-11

    Numerous electron beam applications would benefit from increased average current without sacrificing beam brightness. Work is underway at LLNL to investigate the performance of X-band photoinjectors that would generate electron bunches at a rate matching the RF drive frequency, i.e. one bunch per RF cycle. A critical part of this effort involves development of photo-cathode drive laser technology. Here we present a new laser architecture that can generate pulse trains at repetition rates up to several GHz. This compact, fiber-based system is driven directly by the accelerator RF and so is inherently synchronized with the accelerating fields, and scales readily over a wide range of drive frequencies (L-band through X-band). The system will be required to produce 0.5 {mu}J, {approx}200 fs rise time, spatially and temporally shaped UV pulses designed to optimize the electron beam brightness. Presented is the current status of this system, producing 2 ps pulses from a continuous-wave source.

  14. Self-Consistant Numerical Modeling of E-Cloud Driven Instability of a Bunch Train in the CERN SPS

    International Nuclear Information System (INIS)

    Vay, J.-L.; Furman, M.A.; Secondo, R.; Venturini, M.; Fox, J.D.; Rivetta, C.H.

    2010-01-01

    The simulation package WARP-POSINST was recently upgraded for handling multiple bunches and modeling concurrently the electron cloud buildup and its effect on the beam, allowing for direct self-consistent simulation of bunch trains generating, and interacting with, electron clouds. We have used the WARP-POSINST package on massively parallel supercomputers to study the growth rate and frequency patterns in space-time of the electron cloud driven transverse instability for a proton bunch train in the CERN SPS accelerator. Results suggest that a positive feedback mechanism exists between the electron buildup and the e-cloud driven transverse instability, leading to a net increase in predicted electron density. Comparisons to selected experimental data are also given. Electron clouds have been shown to trigger fast growing instabilities on proton beams circulating in the SPS and other accelerators. So far, simulations of electron cloud buildup and their effects on beam dynamics have been performed separately. This is a consequence of the large computational cost of the combined calculation due to large space and time scale disparities between the two processes. We have presented the latest improvements of the simulation package WARP-POSINST for the simulation of self-consistent ecloud effects, including mesh refinement, and generation of electrons from gas ionization and impact at the pipe walls. We also presented simulations of two consecutive bunches interacting with electrons clouds in the SPS, which included generation of secondary electrons. The distribution of electrons in front of the first beam was initialized from a dump taken from a preceding buildup calculation using the POSINST code. In this paper, we present an extension of this work where one full batch of 72 bunches is simulated in the SPS, including the entire buildup calculation and the self-consistent interaction between the bunches and the electrons. Comparisons to experimental data are also given.

  15. Direct Numerical Modeling of E-Cloud Driven Instability of a Bunch Train in the CERN SPS

    International Nuclear Information System (INIS)

    Vay, J.-L.; Furman, M.A.; Venturini, M.

    2011-01-01

    The simulation package WARP-POSINST was recently upgraded for handling multiple bunches and modeling concurrently the electron cloud buildup and its effect on the beam, allowing for direct self-consistent simulation of bunch trains generating, and interacting with, electron clouds. We have used the WARP-POSINST package on massively parallel supercomputers to study the buildup and interaction of electron clouds with a proton bunch train in the CERN SPS accelerator. Results suggest that a positive feedback mechanism exists between the electron buildup and the e-cloud driven transverse instability, leading to a net increase in predicted electron density. Electron clouds have been shown to trigger fast growing instabilities on proton beams circulating in the SPS and other accelerators. So far, simulations of electron cloud buildup and their effects on beam dynamics have been performed separately. This is a consequence of the large computational cost of the combined calculation due to large space and time scale disparities between the two processes. We have presented the latest improvements of the simulation package WARP-POSINST for the simulation of self-consistent ecloud effects, including mesh refinement, and generation of electrons from gas ionization and impact at the pipe walls. We also presented simulations of two consecutive bunches interacting with electrons clouds in the SPS, which included generation of secondary electrons. The distribution of electrons in front of the first beam was initialized from a dump taken from a preceding buildup calculation using the POSINST code. In this paper, we present an extension of this work where one full batch of 72 bunches is simulated in the SPS, including the entire buildup calculation and the self-consistent interaction between the bunches and the electrons.

  16. Gridded thermionic gun and integral superconducting ballistic bunch compression cavity

    Energy Technology Data Exchange (ETDEWEB)

    Schultheiss, Thomas [Advanced Energy Systems, Inc., Medford, NY (United States)

    2015-11-16

    Electron-Ion colliders such as the Medium energy Electron Ion Collider (MEIC) being developed by JLAB require high current electrons with low energy spread for electron cooling of the collider ring. Accelerator techniques for improving bunch charge, average current, emittance, and energy spread are required for Energy Recovery Linacs (ERLs) and Circulator Rings (CR) for next generation colliders for nuclear physics experiments. Example candidates include thermionic-cathode electron guns with RF accelerating structures. Thermionic cathodes are known to produce high currents and have excellent lifetime. The success of the IR and THz Free-Electron Laser (FEL) designed and installed by Advanced Energy Systems at the Fritz Haber Institute (FHI) of the Max Planck Society in Berlin [1,2] demonstrates that gridded thermionic cathodes and rf systems be considered for next generation collider technology. In Phase 1 Advanced Energy Systems (AES) developed and analyzed a design concept using a superconducting cavity pair and gridded thermionic cathode. Analysis included Beam Dynamics and thermal analysis to show that a design of this type is feasible. The latest design goals for the MEIC electron cooler were for electron bunches of 420 pC at a frequency of 952.6 MHz with a magnetic field on the cathode of 2kG. This field magnetizes the beam imparting angular momentum that provides for helical motion of the electrons in the cooling solenoid. The helical motion increases the interaction time and improves the cooling efficiency. A coil positioned around the cathode providing 2kG field was developed. Beam dynamics simulations were run to develop the particle dynamics near the cathode and grid. Lloyd Young added capability to Tstep to include space charge effects between two plates and include image charge effects from the grid. He also added new pepper-pot geometry capability to account for honeycomb grids. These additions were used to develop the beam dynamics for this gun. The

  17. Dependence of e-cloud on the longitudinal bunch profile: studies in the PS & extension to the HL-LHC

    CERN Document Server

    Bhat, C.M.; Hancock, S.; Mahner, E.; Caspers, F.; Iadarola, G.; Argyropoulos, T.; Zimmermann, F.

    2013-01-01

    Recent studies have shown that the prospects for significantly increasing bunch intensities in the LHC for the luminosity upgrade (HL-LHC) may be severely limited by the available cryogenic cooling capacity and the electron-cloud (EC) driven beam instability. However, it is planned that during the HL-LHC era the bunch intensities in the LHC will go up by nearly a factor of two compared to the LHC-design values. This motivates the exploration of additional EC mitigation techniques that can be adopted in addition to those already in place. Preliminary simulations indicated that long flat bunches can be beneficial over Gaussian bunches to reduce the EC build up. Rigorous studies using realistic bunch profiles have never been done. Therefore, we have undertaken an in-depth investigation in the CERN 26 GeV PS to see if we can validate the previous findings and, in particular, if flattening the bunch can mitigate the EC. Here we present the results from dedicated EC measurements in the PS using a variety of bunch s...

  18. BBAT: Bunch and bucket analysis tool

    International Nuclear Information System (INIS)

    Deng, D.P.

    1995-01-01

    BBAT is written to meet the need of an interactive graphical tool to explore the longitudinal phase space. It is driven for testing new ideas or new tricks quickly. It is especially suitable for machine physicists or operation staff as well both in the control room during machine studies or off-line to analyze the data. The heart of the package contains a set of c-routines to do the number crunching. The graphics part is wired with scripting language tcl/tk and BLT. The c-routines are general enough that one can write new applications such as animation of the bucket as a machine parameter varies via a sliding scale. BBAT deals with single rf system. For double rf system, one can use Dr. BBAT, which stands for Double rf Bunch and Bucket Analysis Tool. One usage of Dr. BBAT is to visualize the process of bunch coalescing and flat bunch creation

  19. Bunching near transition in the BNL AGS

    Directory of Open Access Journals (Sweden)

    C. Ankenbrandt

    1998-07-01

    Full Text Available The proton driver for the muon collider must produce short pulses of protons in order to facilitate muon cooling and operation with polarized beams. In order to test methods of producing these bunches, we have operated the alternating-gradient synchrotron near transition and studied procedures which involved moving the transition energy γ_{t} to the beam energy. We were able to produce stable bunches of 3–5×10^{12} protons with rms widths of σ=2.0–2.7ns for longitudinal bunch areas of 1.5eVs, in addition to making measurements of the lowest two orders of the momentum compaction factor.

  20. Transverse Instability of a Rectangular Bunch

    CERN Document Server

    Balbekov, Valeri

    2005-01-01

    Some results of theoretical investigations of transverse dipole instability of a rectangular bunch are reported in this paper. Such a form is characteristic of the bunch in a rectangular potential wall which is created by a barrier-shaped acceleration field. Similar regime is a major one for accumulating and cooling of antiproton beams in the Fermilab Recycler Ring. In this case, the known theory of transverse instability of a bunched beam is inapplicable directly both because of "unusual" form of phase trajectories and strong dependence of synchrotron frequency on energy. A series of equations, adequately describing the instability is derived in the paper. Exact analytical solution is obtained for space charge dominated impedance, and some approximate methods are proposed for arbitrary impedance. The theory is applied to the Fermilab Recycler Ring including a numerical simulation.

  1. Changes in susceptibility signs on serial T2*-weighted single-shot echo-planar gradient-echo images in acute embolic infarction: comparison with recanalization status on 3D time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kinoshita, Toshibumi; Kinoshita, Fumiko

    2012-01-01

    The present study compares changes in susceptibility signs on follow-up single-shot echo-planar gradient-echo T2*-weighted images (GRE-EPI) with vascular status on follow-up magnetic resonance angiography (MRA) in acute embolic infarction. Twenty consecutive patients with acute embolic infarction repeatedly underwent MR imaging including GRE-EPI and MRA using a 1.5-T MR superconducting system. All patients underwent initial MR examination within 24 h of onset and follow-up MR imaging within 1 month after onset. Changes in susceptibility signs on follow-up GRE-EPI were compatible with vascular status on follow-up MRA in 19 of the 20 patients. Susceptibility signs disappeared with complete recanalization in 13 patients, migrated with partial recanalization in 3, did not change together with the absence of recanalization in 2, and became extended together with the absence of recanalization in 1. Cerebral hemorrhage obscured susceptibility signs in the one remaining patient. Susceptibility signs on follow-up GRE-EPI can reflect changes in an acute embolus, such as recanalization or migration, in this study. Serial GRE-EPI in acute embolism complements the diagnostic certainty of MRA by directly detecting an embolus as a susceptibility sign. (orig.)

  2. Effects of energy chirp on bunch length measurement in linear accelerator beams

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Giribono, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Vaccarezza, C.; Variola, A.

    2017-08-01

    The effects of assumptions about bunch properties on the accuracy of the measurement method of the bunch length based on radio frequency deflectors (RFDs) in electron linear accelerators (LINACs) are investigated. In particular, when the electron bunch at the RFD has a non-negligible energy chirp (i.e. a correlation between the longitudinal positions and energies of the particle), the measurement is affected by a deterministic intrinsic error, which is directly related to the RFD phase offset. A case study on this effect in the electron LINAC of a gamma beam source at the Extreme Light Infrastructure-Nuclear Physics (ELI-NP) is reported. The relative error is estimated by using an electron generation and tracking (ELEGANT) code to define the reference measurements of the bunch length. The relative error is proved to increase linearly with the RFD phase offset. In particular, for an offset of {{7}\\circ} , corresponding to a vertical centroid offset at a screen of about 1 mm, the relative error is 4.5%.

  3. Design considerations for a feedback system to control self-bunching in ion-storage rings

    International Nuclear Information System (INIS)

    Ziemann, V.

    2001-02-01

    We discuss the feasibility of a feedback system to cure self-bunching of the electron-cooled coasting ion-beam in CELSIUS. Such a system may also aid stable operation of accumulator rings for future spallation neutron sources or heavy ion rings used for inertial fusion energy production

  4. A 4 GS/sec Instability Feedback Processing System for Intra-bunch Instabilities

    CERN Document Server

    Dusatko, J; Fox, J D; Pollock, K; Rivetta, C H; Turgut, O; Hofle, W

    2013-01-01

    We present the architecture and implementation overview of a proof-of-principle digital signal processing system developed to study control of Electron-Cloud and Transverse Mode Coupling Instabilities (TMCI) in the CERN SPS. This system is motivated by intensity increases planned as part of the High Luminosity LHC upgrade. It is based on a reconfigurable processing architecture which samples intra-bunch motion and applies correction signals at a 4GSa/s rate, allowing multiple samples across a single 3.2ns SPS bunch. This initial demonstration system is a rapidly developed prototype consisting of both commercial and custom- designed hardware that implements feedback control on a single bunch. It contains a high speed ADC and DAC, capable of sampling at up to 4GSa/s, with a 16-tap FIR control filter for each bunch sample slice. Other system features include a timing subsystem to synchronize the sampling to the injection and the bunch 1 markers, the capability of generating arbitrary time domain signals to drive...

  5. Use of a corrugated beam pipe as a passive deflector for bunch length measurements

    Directory of Open Access Journals (Sweden)

    Jimin Seok

    2018-02-01

    Full Text Available We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch’s longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The astra and elegant simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL Injector Test Facility (ITF, and its results are discussed together with a comparison with the rf deflector measurement.

  6. Kinetic description of neutralized drift compression and transverse focusing of intense ion charge bunches

    Directory of Open Access Journals (Sweden)

    Ronald C. Davidson

    2005-06-01

    Full Text Available A kinetic model based on the Vlasov equation is used to describe the axial drift compression and transverse focusing of an intense ion charge bunch propagating along the axis of a solenoidal focusing field B^{sol}(x. The space charge and current of the ion charge bunch are assumed to be completely neutralized by the electrons provided by a dense background plasma. In the absence of self-field forces, the Vlasov equation is solved exactly for general initial distribution function f_{b}(x,v,0, using the method of characteristics. It is shown that the Vlasov equation possesses a class of exact, dynamically evolving solutions f_{b}(W_{⊥},W_{z}, where W_{⊥} and W_{z} are transverse and longitudinal constants of the motion. Detailed dynamical properties of the charge bunch are calculated during axial compression and transverse focusing for several choices of distribution function f_{b}(W_{⊥},W_{z}.

  7. Excitation of Intra-bunch Vertical Motion in the SPS - Implications for Feedback Control of Ecloud and TMCI Instabilities

    CERN Document Server

    Cesaratto, John; Pivi, M T; Rivetta, C H; Turgut, O; Uemura, S; Hofle, W; Wehrle, U

    2012-01-01

    Electron cloud (ecloud) and transverse mode coupledbunch instabilities (TMCI) limit the bunch intensity in the CERN SPS. This paper presents experimental measurements in the SPS of single-bunch motion driven by a GHz bandwidth vertical excitation system [1]. The nal goal is to quantify the change in internal bunch dynamics as instability thresholds are approached, and quantify the frequencies of internal modes as ecloud effects become signicant. Initially, we have been able to drive the beam and view its motion. We show the excitation of barycentric, head-tail and higher vertical modes at different bunch intensities. The beam motion is analyzed in the time domain, via animated presentations of the sampled vertical signals, and in the frequency domain, via spectrograms showing the modal frequencies vs. time. The demonstration of the excitation of selected internal modes is a signicant step in the development of the feedback control techniques.

  8. Single bunch stability in the ESRF

    International Nuclear Information System (INIS)

    Farvacque, L.

    1990-01-01

    The longitudinal wake potential/impedance and bunch lengthening/stability in ESRF were studied. A cylindrical approximation of individual components of the vacuum chamber were studied. The results are wake potential and loss parameters. Measurements are necessary when the cylindrical approximation is not realistic. The coaxial wire method which is used gives a wake potential that can be substituted for the computed wake in the analysis. A measurement bench is presently being tested at ESRF. Wake potentials (computed or measured) are added before modeling or approximation is made. The impedance model used is the broad-band resonator model. Equations are derived for the longitudinal potential well. The bunch shape can be estimated knowing the first moments of the line density function. Mode coupling cannot explain the turbulent instability threshold. The threshold has then to be estimated by crude assumptions on potential well or bunch shape distortions. In the ESRF case, this threshold corresponds to a value of asymmetry s (th) = 0.6. Above the threshold the bunch lengthens with this constant asymmetry value

  9. Introduction to impedance for short relativistic bunches

    International Nuclear Information System (INIS)

    Morton, P.L.

    1993-02-01

    The purpose of this paper is to introduce the concept of impedance to calculate the wake field forces left behind by a short bunch which travels at relativistic speed through a structure with discontinuities. We will try to be as intuitive as possible and leave the more rigorous derivations to the second paper on this subject by J. Wang

  10. Bunch length measurement using coherent Cherenkov radiation

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Ogata, A.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2011-01-01

    A new method for bunch diagnostic based on multimode Coherent Cherenkov Radiation (CCR) was proposed. Generation of quasi-monochromatic terahertz (THz) using multimode CCR on the order of 0.1 THz was carried out. The intensity and frequency of CCR were measured directly by a Michelson interferometer and a bolometer. (author)

  11. An improved injector bunching geometry for ATLAS

    Indian Academy of Sciences (India)

    Abstract. The bunching system of the ATLAS positive ion injector (PII) has been improved by relocating the harmonic buncher to a point significantly closer to the second stage sine-wave buncher and the injector LINAC. The longitudinal optics design has also been modified and now employs a virtual waist from the ...

  12. Imaging and electron energy-loss spectroscopy using single nanosecond electron pulses.

    Science.gov (United States)

    Picher, Matthieu; Bücker, Kerstin; LaGrange, Thomas; Banhart, Florian

    2018-03-13

    We implement a parametric study with single electron pulses having a 7 ns duration to find the optimal conditions for imaging, diffraction, and electron energy-loss spectroscopy (EELS) in the single-shot approach. Photoelectron pulses are generated by illuminating a flat tantalum cathode with 213 nm nanosecond laser pulses in a 200 kV transmission electron microscope (TEM) with thermionic gun and Wehnelt electrode. For the first time, an EEL spectrometer is used to measure the energy distribution of single nanosecond electron pulses which is crucial for understanding the ideal imaging conditions of the single-shot approach. By varying the laser power, the Wehnelt bias, and the condenser lens settings, the optimum TEM operation conditions for the single-shot approach are revealed. Due to space charge and the Boersch effect, the energy width of the pulses under maximized emission conditions is far too high for imaging or spectroscopy. However, by using the Wehnelt electrode as an energy filter, the energy width of the pulses can be reduced to 2 eV, though at the expense of intensity. The first EEL spectra taken with nanosecond electron pulses are shown in this study. With 7 ns pulses, an image resolution of 25 nm is attained. It is shown how the spherical and chromatic aberrations of the objective lens as well as shot noise limit the resolution. We summarize by giving perspectives for improving the single-shot time-resolved approach by using aberration correction. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Single shot high resolution digital holography.

    Science.gov (United States)

    Khare, Kedar; Ali, P T Samsheer; Joseph, Joby

    2013-02-11

    We demonstrate a novel computational method for high resolution image recovery from a single digital hologram frame. The complex object field is obtained from the recorded hologram by solving a constrained optimization problem. This approach which is unlike the physical hologram replay process is shown to provide high quality image recovery even when the dc and the cross terms in the hologram overlap in the Fourier domain. Experimental results are shown for a Fresnel zone hologram of a resolution chart, intentionally recorded with a small off-axis reference beam angle. Excellent image recovery is observed without the presence of dc or twin image terms and with minimal speckle noise.

  14. Direct observation of beam bunching in BWO experiments

    CERN Document Server

    Morimoto, I; Maebara, S; Kishiro, J; Takayama, K; Horioka, K; Ishizuka, H; Kawasaki, S; Shiho, M

    2001-01-01

    Backward Wave Oscillation (BWO) experiments using a Large current Accelerator-1 (Lax-1) Induction Linac as a seed power source for an mm-wave FEL are under way. The Lax-1 is typically operated with a 1 MeV electron beam, a few kA of beam current, and a pulse length of 100 ns. In the BWO experiments, annular and solid beams are injected into a corrugated wave guide with guiding axial magnetic field of 1 T. In the BWO with annular beam an output power of 210 MW at 9.8 GHz was obtained. With a solid beam the output power was 130 MW, and an electron beam bunching with the frequency of 9.6-10.2 GHz was observed by a streak camera.

  15. Proceedings of the impedance and bunch instability workshop

    Energy Technology Data Exchange (ETDEWEB)

    1990-04-01

    This report discusses the following topics: impedance and bunch lengthening; single bunch stability in the ESRF; a longitudinal mode-coupling instability model for bunch lengthening; high-frequency behavior of longitudinal coupling impedance; beam-induced energy spreads at beam-pipe transitions; on the calculation of wake functions using MAFIA-T3 code; preliminary measurements of the bunch length and the impedance of LEP; measurements and simulations of collective effects in the CERN SPS; bunch lengthening in the SLC damping rings; and status of impedance measurements for the spring-8 storage ring.

  16. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  17. Coherent synchrotron radiation and bunch stability in a compactstorage ring

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, Marco; Warnock, Robert; Ruth, Ronald; Ellison, James A.

    2004-04-09

    We examine the effect of the collective force due to coherent synchrotron radiation (CSR) in an electron storage ring with small bending radius. In a computation based on time-domain integration of the nonlinear Vlasov equation, we find the threshold current for a longitudinal microwave instability induced by CSR alone. The model accounts for suppression of radiation at long wave lengths due to shielding by the vacuum chamber. In a calculation just above threshold, small ripples in the charge distribution build up over a fraction of a synchrotron period, but then die out to yield a relatively smooth but altered distribution with eventual oscillations in bunch length. The instability evolves from small noise on an initial smooth bunch of r.m.s.length much greater than the shielding cutoff. The paper includes a derivation and extensive analysis of the complete impedance function Z for synchrotron radiation with parallel plate shielding. We find corrections to the lowest approximation to the coherent force which involve ''off-diagonal'' values of Z, that is, fields with phase velocity not equal to the particle velocity.

  18. Beam manipulation with velocity bunching for PWFA applications

    Science.gov (United States)

    Pompili, R.; Anania, M. P.; Bellaveglia, M.; Biagioni, A.; Bisesto, F.; Chiadroni, E.; Cianchi, A.; Croia, M.; Curcio, A.; Di Giovenale, D.; Ferrario, M.; Filippi, F.; Galletti, M.; Gallo, A.; Giribono, A.; Li, W.; Marocchino, A.; Mostacci, A.; Petrarca, M.; Petrillo, V.; Di Pirro, G.; Romeo, S.; Rossi, A. R.; Scifo, J.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Zhu, J.

    2016-09-01

    The activity of the SPARC_LAB test-facility (LNF-INFN, Frascati) is currently focused on the development of new plasma-based accelerators. Particle accelerators are used in many fields of science, with applications ranging from particle physics research to advanced radiation sources (e.g. FEL). The demand to accelerate particles to higher and higher energies is currently limited by the effective efficiency in the acceleration process that requires the development of km-size facilities. By increasing the accelerating gradient, the compactness can be improved and costs reduced. Recently, the new technique which attracts main efforts relies on plasma acceleration. In the following, the current status of plasma-based activities at SPARC_LAB is presented. Both laser- and beam-driven schemes will be adopted with the aim to provide an adequate accelerating gradient (1-10 GV/m) while preserving the brightness of the accelerated beams to the level of conventional photo-injectors. This aspect, in particular, requires the use of ultra-short (< 100 fs) electron beams, consisting in one or more bunches. We show, with the support of simulations and experimental results, that such beams can be produced using RF compression by velocity-bunching.

  19. Complex soliton bunching patterns induced by nonsaturable absorption

    Science.gov (United States)

    Chen, Weicheng; Luo, Aiping

    2017-10-01

    A fiber laser with a semiconductor saturable absorption mirror (SESAM) and a graphene-polymer composite (GPC) film is constructed for achieving different soliton bunching patterns. The SESAM is used as a mode locker for self-started pulse generation, while the GPC provides a nonsaturable absorption effect for achieving a bunching in the laser cavity. There are three extra temporal patterns observed in the experiments through adjusting polarization controllers. They are chaotic bunching, weak coherent bunching and modulated harmonic bunching. The experimental investigation shows that dynamic nonsaturable absorption effect of an absorber is beneficial for generating different bunching patterns. Our work can have a deeper understanding of the formation of the complex soliton bunching patterns in pulsed lasers.

  20. Shielded transient self-interaction of a bunch entering a circle from a straight path

    International Nuclear Information System (INIS)

    Li, R.; Bohn, C.L.; Bisognano, J.J.

    1997-01-01

    Recent developments in electron-gun and injector technologies enable production of short (mm-length), high-charge (nC-regime) bunches. In this parameter regime, the curvature effect on the bunch self-interaction, by way of coherent synchrotron radiation (CSR) and space-charge forces as the beam traverses magnet bends, may cause serious emittance degradation. In this paper, the authors study an electron bunch orbiting between two infinite, parallel conducting plates. The bunch moves on a trajectory from a straight path to a circular orbit and begins radiating. Transient effects, arising from CSR and space-charge forces generated from source particles both on the bend and on the straight path prior to the bend, are analyzed using Lienard-Wiechert fields, and their overall net effect is obtained. The influence of the plates on the transients is contrasted to their shielding of the steady-state radiated power. Results for emittance degradation induced by this self-interaction are also presented

  1. Halo formation in three-dimensional bunches

    International Nuclear Information System (INIS)

    Gluckstern, R.L.; Fedotov, A.V.; Kurennoy, S.; Ryne, R.

    1998-01-01

    We have constructed, analytically and numerically, a class of self-consistent six-dimensional (6D) phase space stationary distributions. Stationary distributions allow us to study the halo development mechanism without it being obscured by beam redistribution and its effect on halo formation. The beam is then mismatched longitudinally and/or transversely, and we explore the formation of longitudinal and transverse halos in 3D axisymmetric beam bunches. We find that the longitudinal halo forms first for comparable longitudinal and transverse mismatches because the longitudinal tune depression is more severe than the transverse one for elongated bunches. Of particular importance is the result that, due to the coupling between longitudinal and transverse motion, a longitudinal or transverse halo is observed for a mismatch less than 10% if the mismatch in the other plane is large. copyright 1998 The American Physical Society

  2. Bunching and cooling of radioactive ions with REXTRAP

    CERN Document Server

    Schmidt, P; Bollen, G; Forstner, O; Huber, G; Oinonen, M; Zimmer, J

    2002-01-01

    The post-accelerator REX-ISOLDE at ISOLDE/CERN will deliver radioactive ion beams with energies up to 2.2 MeV/u. For this purpose, a Penning trap and an electron-beam ion source are combined with a linear accelerator. REXTRAP—a large gas-filled Penning trap—has started its commissioning phase. First tests have shown that REXTRAP is able to accumulate, cool and bunch stable ISOLDE ion beams covering a large mass range. Fulfilling the REX-ISOLDE demands, it can handle beam intensities from a few hundred up to 1×10 6 ions per pulse at repetition rates up to 50 Hz.

  3. Single bunch transfer system for the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Sheehan, J.; Singh, O.; Rambo, W.

    1983-01-01

    The accelerator system at the National Synchrotron Light Source consists of an S-band 85 MeV linac and three synchrotron rings. The electron beam from the linac is accelerated by the booster ring to 600 MeV and transferred to one of the two storage rings. The smaller of the two rings operates between 300 and 800 MeV emtting photons in the vacuum ultraviolet (VUV), while the larger storage ring operates up to 2.5 GeV and emits photons in the x-ray spectrum. A system is described for loading the storage rings by filling a single-phase space bunch in the booster ring and transferring it at the end of each booster cycle into a selected bucket in one of the storage rings. By controlling the timing of the transfer on successive transfer cycles, many fill patterns may be obtained

  4. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  5. Threshold behavior for longitudinal stability of induction linac bunches

    International Nuclear Information System (INIS)

    Bisognano, J.; Haber, I.; Smith, L.

    1983-01-01

    The induction linac bunches of heavy ion fusion scenarios are strongly influenced by the longitudinal space charge impedance. This is in distinct contrast to relativistic bunches in storage rings where most of the data on stability have been obtained. Simulation results reveal that when space charge effects are large, the stability requirement of small growth rate relative to the synchrotron frequency for relativistic bunches is replaced by the relaxed condition of small growth rate relative to the frequency spacing of the space charge wave modes on the bunch. Dispersive effects from finite pipe size tend to make the lower frequencies less susceptible to instability than higher frequencies. Since induction modules have a high resistive component only for the lowest bunch modes, stability is better than would occur for a broadband impedance of comparable magnitude. These results indicate that long term longitudinal bunch stability is realizable for induction linac drivers for heavy ion fusion

  6. First Observation of the Seeded Proton Bunch Self-Modulation in Plasma

    CERN Document Server

    AUTHOR|(CDS)2093171; Vincke, Helmut

    In this thesis I observe experimentally and study in simulations the seeded selfmodulation of a relativistic proton bunch in AWAKE, the Advanced Proton Driven Plasma Wakefield Acceleration Experiment. The 400 GeV/c proton bunch from the CERN SPS with a rms length of 12 cm propagates in a 10m long plasma with a density adjustable between 2-10x10^14 electrons/cm3. The seeded self-modulation process results in focusing and defocusing of the protons, thereby forming a bunch train that resonantly drives wakefields to large amplitudes. I use the two-screen measurement setup, to observe the result of the proton bunch self-modulation and to learn about its physics (i.e. growth of the process). The idea is to obtain images of protons that were defocused by the transverse wakefields, 2 and 10m downstream the end of the plasma. From these images I determine the maximum transverse momentum of the defocused protons as well as infer their point of origin along the plasma. I use simulations to guide the understanding of the...

  7. High Charge PHIN Photo Injector at CERN with Fast Phase switching within the Bunch Train for Beam Combination

    CERN Document Server

    Csatari Divall, M; Bolzon, B; Bravin, E; Chevallay, E; Dabrowski, A; Doebert, S; Drozdy, A; Fedosseev, V; Hessler, C; Lefevre, T; Livesley, S; Losito, R; Olvegaard, M; Petrarca, M; Rabiller, A N; Egger, D; Mete, O

    2011-01-01

    The high charge PHIN photo-injector was developed within the framework of the European CARE program to provide an alternative to the drive beam thermionic gun in the CTF3 (CLIC Test Facility) at CERN. In PHIN 1908 electron bunches are delivered with bunch spacing of 1.5 GHz and 2.33 nC charge per bunch. Furthermore the drive beam generated by CTF3 requires several fast 180 deg phase-shifts with respect to the 1.5 GHz bunch repetition frequency in order to allow the beam combination scheme developed at CTF3. A total of 8 subtrains, each 140 ns long and shifted in phase with respect to each other, have to be produced with very high phase and amplitude stability. A novel fiber modulator based phase-switching technique developed on the laser system provides this phase-shift between two consecutive pulses much faster and cleaner than the base line scheme, where a thermionic electron gun and sub-harmonic bunching are used. The paper describes the fiber-based switching system and the measurements verifying the schem...

  8. Design, development and use of the spectrometer for investigating coherent THz radiation produced by micro-bunching instabilities at Diamond Light Source

    Science.gov (United States)

    Finn, Aiveen; Karataev, Pavel; Rehm, Guenther

    2016-07-01

    Schottky barrier diodes (SBDs) are known for their low noise, ultra-fast response and excellent sensitivity. They are often implemented as detectors in the millimetre wavelength regime. Micro-bunch instabilities (MBI) have been detected at many light sources around the world including the Diamond Light Source, UK. These MBI can result in bursts of coherent synchrotron radiation (CSR) with millimetre wavelengths. More research needs to be carried out with regards to the dynamics of MBI in order to confirm the simulations and to eventually harness the power of the CSR bursts. A single shot spectrometer has been designed and is under operation at the Diamond Light Source (DLS). It is composed of eight SBDs ranging from 33-1000 GHz. Unlike previous measurements carried out, each of the SBDs has been individually characterised thus making the results obtained comparable to simulations. In this paper, we present the assessment of each SBD in the spectrometer and the first results of the spectrometer's use in the beam.

  9. Design, development and use of the spectrometer for investigating coherent THz radiation produced by micro-bunching instabilities at Diamond Light Source

    International Nuclear Information System (INIS)

    Finn, Aiveen; Karataev, Pavel; Rehm, Guenther

    2016-01-01

    Schottky barrier diodes (SBDs) are known for their low noise, ultra-fast response and excellent sensitivity. They are often implemented as detectors in the millimetre wavelength regime. Micro-bunch instabilities (MBI) have been detected at many light sources around the world including the Diamond Light Source, UK. These MBI can result in bursts of coherent synchrotron radiation (CSR) with millimetre wavelengths. More research needs to be carried out with regards to the dynamics of MBI in order to confirm the simulations and to eventually harness the power of the CSR bursts. A single shot spectrometer has been designed and is under operation at the Diamond Light Source (DLS). It is composed of eight SBDs ranging from 33-1000 GHz. Unlike previous measurements carried out, each of the SBDs has been individually characterised thus making the results obtained comparable to simulations. In this paper, we present the assessment of each SBD in the spectrometer and the first results of the spectrometer's use in the beam. (paper)

  10. More Options for the NLC Bunch Compressors (LCC-0035)

    International Nuclear Information System (INIS)

    Emma, P.

    2004-01-01

    The present bunch compressor design for the NLC allows control of the final bunch length by way of changes to the horizontal betatron phase advance of the 180 o -turnaround arc. This adjustability requirement significantly constrains the design and cost optimization of the system and excludes the possibility of using permanent magnet quadrupoles in the arc. To relieve this constraint, and to avoid the very strong arc focusing required at the upper limits of the bunch length range, we explore an option of bunch length control using the first compressor stage, with the arc optics fixed

  11. POSITION DETERMINATION OF CLOSELY SPACED BUNCHES USING CAVITY BPMs

    CERN Document Server

    Joshi, N; Cullinan, F; Lyapin, A

    2011-01-01

    Radio Frequency (RF) Cavity Beam Position Monitor (BPM) systems form a major part of precision position measurement diagnostics for linear accelerators with low emittance beams. Using cavity BPMs, a position resolution of less than 100 nm has been demonstrated in single bunch mode operation. In the case of closely spaced bunches, where the decay time of the cavity is comparable to the time separation between bunches, the BPM signal from a bunch is polluted by the signal induced by the previous bunches in the same bunch-train. This paper discusses our ongoing work to develop the methods to extract the position of closely spaced bunches using cavity BPMs. A signal subtraction code is being developed to remove the signal pollution from previous bunches and to determine the individual bunch position. Another code has been developed to simulate the BPM data for the cross check. Performance of the code is studied on the experimental and simulated data. Application of the analysis techniques to the linear colliders,...

  12. Bunch length measurements in the SLC damping ring

    International Nuclear Information System (INIS)

    Decker, F.J.; Limberg, T.; Minty, M.; Ross, M.

    1993-05-01

    The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch muncher) to shorten the bunch length. Measurements under these different conditions are presented and compared with BPM pulse height signals. Calibration and adjustment issues and the connection of the streak camera to the SLC control system are also discussed

  13. Subpicosecond bunch train production for a tunable mJ level THz source.

    Science.gov (United States)

    Antipov, S; Babzien, M; Jing, C; Fedurin, M; Gai, W; Kanareykin, A; Kusche, K; Yakimenko, V; Zholents, A

    2013-09-27

    A strong energy modulation in an electron bunch passing through a dielectric-lined waveguide was recently demonstrated in Antipov et al., Phys. Rev. Lett. 108, 144801 (2012). In this Letter, we demonstrate a successful conversion of this energy modulation into a beam density modulation, and the formation of a series of microbunches with a subpicosecond periodicity by means of magnetic optics (chicane). A strong coherent transition radiation signal produced by the microbunches is obtained and the tunability of its carrier frequency in the 0.68-0.9 THz range by regulating the energy chirp in the incoming electron bunch is demonstrated using infrared interferometry. A tabletop, compact, tunable, and narrowband source of intense THz radiation based on this technology is proposed.

  14. Controlling nonlinear longitudinal space charge oscillations for high peak current bunch train generation

    Directory of Open Access Journals (Sweden)

    P. Musumeci

    2013-10-01

    Full Text Available The evolution of picosecond modulations of the longitudinal profile of an electron beam generated in an rf photoinjector is analyzed and optimized with the goal of obtaining high peak current electron bunch trains at very high frequencies (≥THz. Taking advantage of nonlinear longitudinal space charge forces, it is found that more than 500 A peak current 1 THz bunch trains can be generated using a standard 1.6 cell SLAC/UCLA/BNL rf gun. Postacceleration is used to freeze the longitudinal phase space dynamics after one half plasma oscillation. Applications range from tunable narrow bandwidth THz radiation generation to drivers for high frequency high gradient accelerators.

  15. Electron Cloud in the LHC

    CERN Document Server

    Ruggiero, F

    1998-01-01

    A theoretical and experimental crash program has been set up at CERN to investigate electron cloud effects in the LHC. In particular, I report about recent estimates of the critical secondary-emission yield, versus bunch population and bunch spacing, and ongoing multipacting tests with a coaxial resonator in a strong magnetic field.

  16. Phase measurement and control of bunched beams

    International Nuclear Information System (INIS)

    Lewis, R.N.

    1978-01-01

    An ion bean buncher was developed at ANL for bunching all ion species through a tandem accelerator. Transit time variations through the tandem, caused by ripple and fluctuations in the injection and lens power supplies and terminal voltage, and to varying voltage distributions in the accelerating tube, cause a beam-phase variation at the output of the tandem. A beam-phase measurement and control system was designed and installed in conjunction with the ion beam buncher to control beam phase at the tandem output. That system is described

  17. E-Cloud Drivent Single-Bunch Instabilities in PS2

    International Nuclear Information System (INIS)

    Venturini, M.; Furman, M.; Penn, G.; Secondo, R.; Vay, J.-L.; De Maria, R.; Papaphilippou, Y.; Rumolo, G.

    2010-01-01

    One of the proposals under consideration for future upgrades of the LHC injector complex entails the replacement of the PS with the PS2, a longer circumference and higher energy synchrotron, with electron cloud effects representing a potentially serious limitation to the achievement of the upgrade goals. We report on ongoing numerical studies aiming at estimating the e-cloud density threshold for the occurrence of single bunch instabilities.

  18. Hydroxynortriptyline of Empty Fruit Bunches Fibre using Polyethylene glycol (PEG)

    International Nuclear Information System (INIS)

    Noreen, F.M.Z.; Sarani Zakaria

    2013-01-01

    The aim of this study was to investigate the reaction of oil palm empty fruit bunches fibre (EFBF) via chemical modification and hydroxynortriptyline method using polyethylene glycol (PEG). The first stage was the modification of EFB fibre using NaOH and isopropanol. The next stage was the preparation of hydroxypropylated-empty fruit bunches fibre (HP-EFBF), using different molecular weight of PEG (6,000, 8,000 and 10,000). The characterisation involved in this study were conducted by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), thermogravimetry analysis (TGA), determination of kinetic activation energy (E a ), X-ray diffraction (XRD), cellulose crystallinity index (CrI) and weight increment of the HP-EFB fibre. SEM results showed the surface of HP-EFBF swelled and craters formed along the surface of the fibre. IR spectrum also showed OH stretching band in EFB without treatment is 3402 cm -1 , but after hydroxynortriptyline process, the OH stretching band in HP-EFBF (10000, 8000 and 6000) slightly shifted to 3392, 3384 and 3370 cm -1 , respectively. TGA showed the thermal stability of HP-EFBF 6,000 was lower than HP-EFBF 8,000 and 10,000. After chemical modification, the activation energy, E a increased from 32.4 to 51.9 kJ/ mol more than EFB without treatment, 12.5 kJ/ mol. XRD showed that diffraction peak (002) shifted to the smaller 2θ angle and the peaks (101, 10I) disappeared after hydroxynortriptyline process. Crystallinity index, of EFB without treatment decreased from 27 % to 25 % after chemical modification. The higher the molecular weight of the PEG, the greater the weight increment of the HP-EFBF. (author)

  19. Damage in solids irradiated by a single shot of XUV free-electron laser: irreversible changes investigated using X-ray microdiffraction, atomic force microscopy and Nomarski optical microscopy

    Czech Academy of Sciences Publication Activity Database

    Pelka, J. B.; Sobierajski, R.; Klinger, D.; Paszkowicz, W.; Krzywinski, J.; Jurek, M.; Zymierska, D.; Wawro, A.; Petroutchik, A.; Juha, Libor; Hájková, Věra; Cihelka, Jaroslav; Chalupský, Jaromír; Burian, T.; Vyšín, Luděk; Toleikis, S.; Sokolowski-Tinten, K.; Stojanovic, N.; Zastrau, U.; London, R.; Hau-Riege, S.; Riekel, C.; Davies, R.; Burghammer, M.; Dynowska, E.; Szuszkiewicz, W.; Caliebe, W.; Nietubyc, R.

    2009-01-01

    Roč. 78, Suppl. 10 (2009), S46-S52 ISSN 0969-806X R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : XUV FEL * radiation damage * ablation * structure modifications * x-ray diffraction Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.149, year: 2009

  20. Measurement of self-shaped ellipsoidal bunches from a photoinjector with postacceleration

    Directory of Open Access Journals (Sweden)

    Brendan O’Shea

    2011-01-01

    Full Text Available Recent work has shown the possibility of generating self-shaped ellipsoidal beams with properties commensurate with the requirements of future light sources such as free-electron lasers and inverse Compton sources. In this so-termed “blowout” regime, short laser bunches are transformed via photoemission into short electron bunches which then self-consistently evolve into nearly uniform-density ellipsoids under space-charge forces. We report here on the first blowout studies conducted in collaboration between the UCLA Particle Beam Physics Lab and the Photo Injector Test Facility, Zeuthen (PITZ. The measurements conducted at the PITZ photoinjector facility examine the evolution of 750 pC, 2.7 ps FWHM electron bunches born in an L-band photoinjector and subsequently accelerated through a nine-cell L-band booster for a resulting energy of 12 MeV. These measurements represent the first observations of self-shaped ellipsoid evolution under postinjector acceleration, a key step in demonstrating the utility of such self-shaped beams at higher energy, where the advantages in both transverse and longitudinal and transverse phase space may be exploited in creating very high brightness beams.